INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Layer 2 Industrially Hardened Managed Ethernet Switch
All Gigabit 24 TX with PoE+ and 4 Combo Ports
The ComNet CNGE28FX4TX24MS(2,POE2/48) Layer 2 Managed 28 Port Ethernet
Switch supports twenty-four 10/100/1000 BASE-TX ports and four 10/100/1000
BASE-TX or 100/1000 BASE-FX SFP Combo ports of Ethernet data. PoE+ power is
CNGE28FX4TX24MS2
available for distribution across all 24 BASE-TX ports. The four combination ports are
CNGE28FX4TX24MSPOE2/48
10/100/1000TX or 100/1000FX SFP configurable for fiber type (multimode or singlemode), connector type and distance. Dual 48 VDC input power design ensures vital
network capabilities with minimum downtime. Utilizing RSTP/STP (802.1w/1D) MSTP,
and X-Ring redundant ring topologies, a network recovery time of <20 ms is provided
for protection from network faults or temporary interruptions. The switch is optically
(100/1000BASE-FX) and electrically compatible with any IEEE 802.3 compliant
Ethernet device and are hardened for use in harsh operating environments.
This manual serves the following
ComNet Model Numbers:
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Contents
Regulatory Compliance Statement
4
Warranty
4
Disclaimer
4
Safety Indications
4
Federal Communication Commission Interference Statement 5
Declaration of Conformity
5
Safety Instructions
6
1.0 Product Overview
7
1.1 Specifications
7
1.2. Hardware Views
8
1.3 Dimensions
11
1.4. Packing List
12
2.0 Installation Guidelines
13
2.1. Warnings
13
2.2. Installation Guidelines
14
2.4. Verifying Switch Operation
15
2.5. Installing the Switch
16
2.6. Installing and Removing SFP Modules
17
2.7. Connecting the Switch to Ethernet Ports
20
2.8. Connecting the Switch to Console Port
21
2.9. Power Supply Installation
22
2.10. Reset Button
25
3.0 Setup
26
3.1. First Time Setup
26
3.2. Command Line Interface Configuration
30
3.3. Web Browser Configuration
31
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 2
INSTALLATION AND OPERATION MANUAL
4.0. Switch Management
CNGE28FX4TX24MS(2,POE2/48)
32
4.1. Log In
32
4.2. Recommended Practices
33
4.3. Monitoring
34
4.4. System
40
4.5. L2 Switching
47
4.6. MAC Address Table
82
4.7. Security
85
4.8. QoS
99
4.9. Management
111
4.10 Diagnostics
135
4.11. Tools
145
APPENDIX
Troubleshooting
151
151
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 3
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Regulatory Compliance Statement
Product(s) associated with this publication complies/comply with all applicable regulations. Please
refer to the Technical Specifications section for more details.
Warranty
ComNet warrants that all ComNet products are free from defects in material and workmanship
for a specified warranty period from the invoice date for the life of the installation. ComNet will
repair or replace products found by ComNet to be defective within this warranty period, with
shipment expenses apportioned by ComNet and the distributor. This warranty does not cover
product modifications or repairs done by persons other than ComNet-approved personnel, and
this warranty does not apply to ComNet products that are misused, abused, improperly installed,
or damaged by accidents.
Please refer to the Technical Specifications section for the actual warranty period(s) of the
product(s) associated with this publication.
Disclaimer
Information in this publication is intended to be accurate. ComNet shall not be responsible for its
use or infringements on third-parties as a result of its use. There may occasionally be unintentional
errors on this publication. ComNet reserves the right to revise the contents of this publication
without notice.
Note. The PoE port may be considered SELV circuits, if:
»» Not likely to require connection to an Ethernet network with outside plant routing including
campus environment; and
»» The installation instructions clearly state that the ITE is to be connected only to PoE Networks
without routing to the outside plant.
Safety Indications
»» The equipment can only be accessed by a service person or users who have been instructed.
»» The equipment should be installed in the location that needs a tool or lock and key, or other
means of security, and controlled by a person of authority.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 4
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Federal Communication Commission Interference Statement
For further certification information, please go to www.comnet.net
Declaration of Conformity
CE
This product has passed the CE test for environmental specifications when shielded cables are
used for external wiring. We recommend the use of shielded cables. Please contact your local
supplier for ordering information.
This product has passed the CE test for environmental specifications. Test conditions for passing
included the equipment being operated within an industrial enclosure. In order to protect the
product from being damaged by ESD (Electrostatic Discharge) and EMI leakage, we strongly
recommend the use of CE-compliant industrial enclosure products.
FCC Class A
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at their own
expense.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 5
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Safety Instructions
Read these safety instructions carefully.
»» Keep this user manual for later reference.
»» Disconnect this equipment from any AC outlet before cleaning. Use damp cloth. Do not use
liquid or spray detergents for cleaning.
»» For plug-in equipment, the power outlet socket must be located near the equipment and must
be easily accessible.
»» Keep this equipment away from humidity.
»» Put this equipment on a stable surface during installation. Dropping it or letting it fall may
cause damage.
»» The openings on the enclosure allow for air convection. Protect the equipment from over­
heating. DO NOT COVER THE OPENINGS.
»» Make sure the voltage of the power source is correct before connecting the equipment to the
power outlet.
»» Position the power cord so that people cannot step on it. Do not place anything over the
power cord.
»» All cautions and warning on the equipment should be noted.
»» If the equipment is not used for a long time, disconnect it from the power source to avoid
damage by transient over voltage.
»» Never pour any liquid into an opening. This may cause fire or electrical shock.
»» Never open the equipment. For safety reasons, the equipment should be opened only by
qualified service personnel.
»» If one of the following situations arises, get the equipment checked by service person­nel:
›› The power cord or plug is damaged.
›› Liquid has penetrated into the equipment.
›› The equipment has been exposed to moisture.
›› The equipment does not work well, or you cannot get it to work according to the user
manual
›› The equipment has been dropped and damaged.
›› The equipment has obvious signs of breakage.
»» PoE requirements: The equipment is to be connected only to PoE networks without routing to
the outside plant.
»» Do not leave this equipment in an environment where the storage temperature may go below
-40°C (-40°F) or above 75°C (167°F) this could damage the equipment. The equipment should
be in a controlled environment.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 6
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
1.0 Product Overview
1.1 Specifications
Specifications
Description
Interface
I/O Port
24 x 10/100/1000BaseT(X) + 4 x 10/100/1000Base-T(X) or 4
x 100/1000Base-X SFP Port
Power Connector
4-pin screw terminal
Relay Connector
3-pin screw terminal
Enclosure
Metal Shell
Protection Class
IP30
Installation
Rack mounting
Dimensions (W x H x D)
438.0 x 43.6 x 259.2mm
System LED
SYS, PWR1, PWR2, P-Fail, Loop detection, R.M., Ring Fail,
Temp
Port LED
Speed, Link, Activity, PoE (only for
CNGE28FX4TX24MSPOE2/48)
Operating Temperature
-40°C ~ 75°C (-40°F ~ 167°F)
Storage Temperature
-40°C ~ 85°C (-40°F ~ 185°F)
Physical
LED Display
Environment
Ambient Relative Humidity 10 ~ 95% (non-condensing)
Switch Properties MAC Address
Power
Certifications
8K-entry
Switching Bandwidth
56 Gbps
Power Consumption
CNGE28FX4TX24MS2: 20W @ 24V
CNGE28FX4TX24MSPOE2/48: 20W @ 48V (before PoE Load)
Power Input
CNGE28FX4TX24MS2: 12 - 48 VDC
CNGE28FX4TX24MSPOE2/48: 48 VDC (46 - 57 VDC) for PoE
system (53 - 57 VDC is recommended for PoE+ devices)
Safety
IEC EN60950, EN61010
EMC
CE, FCC
EMI
EN55022 Class A
EMS
EN 61000-4-2 (ESD) Level 3
EN 61000-4-3 (RS) Level 3
EN 61000-4-4 (EFT) Level 3
EN 61000-4-5 (Surge) Level 3
EN 61000-4-6 (CS) Level 3
EN 61000-4-8 (Magnetic Field) Level 3
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Railway Track Side
EN 50121-4
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 7
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
1.2. Hardware Views
1.2.1 Front View
1
2
3
4
5
67
8
Front View
No.
Item
Description
1
Reset button
Button allows for system soft reset or factory default reset.
2
System LED panel
See “System LED Panel” on page 4 for further details.
3
ETH port
RJ45 ports x 4
4
SFP LEDs
SFP link activity LEDs
5
ETH port
Fiber ports x 4
6
PoE LED
Orange: 100M
Green: 1G
7
LNK/ACT LED
Link activity LED
8
ETH port
RJ45 ports x 24
System LED Panel
1
2
3
4
5
10
6
7
11
9
8
Figure 1-2. System LED Panel Table 1-3. System LED Panel
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 8
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 1-3. System LED Panel (Continued)
No.
LED Name
LED Color
Description
1
SYS
Solid Green
System is operating normally
Off
System is powered down / system crash / operation initiating.
Solid green
Powered up
Off
Powered down or not installed
Solid Green
Powered Up
Off
Powered down or not installed
Solid Red
PWR1 or PWR2 is disconnected
Off
PWR1 or PWR2 connected
Solid Red
Loop detected
Off
No loop detected
Solid Green
Switch is Ring Master
Solid Green
SFP plug-in and link up
Blink Green
Packet transmit/receive
Off
SFP unplugged or link down
Solid Green
Connected to power supply and able to act as PSE
Off
Disconnected from power supply and unable to act as PSE
Solid green
Current link speed is 1000M.
Blink green
Packet transmit and receive.
Off
No link.
Solid amber
Current link speed is 100/10M.
Blink amber
Packet transmit and receive.
Off
No link.
2
3
4
5
PWR
PWR2
P-FAIL
LOOP
6
R.M.
7
Ring Fail
8
Temp
SFP
9
SFP LED
RJ45
10
11
PoE
LNK/ACT
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 9
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
1.2.2 Rear View
1
2
3
4
.
Figure 1-3. Rear View
Table 1-4. Rear View
No.
Item
Description
1
Ground terminal
Screw terminal used to ground chassis.
2
Console serial port
Console cable port to COM port (DB9 male) on computer to RS232
managed switch (RJ45 female).
3
P-Fail block
Connect cabling for alarm wiring.
4
Power block
Connect cabling for power wiring.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 10
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
1.3 Dimensions
Figure 1-4. CNGE28FX4TX24MSPOE2/48 Dimensions
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 11
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
1.4. Packing List
The product package you have received should contain the following items. If any of them are not
included or are damaged, please contact your local vendor for support.
»» 1 × Industrial Ethernet Switch
»» 1 × Rack Mount Kit
»» 1 × Quick Start Guide
»» 1 × Serial Console Cable
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 12
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.0 Installation Guidelines
2.1. Warnings
Warning: Before working on equipment that is connected to power lines, remove any jewelry
(including rings, necklaces, and watches). Metal objects can heat up when connected to power
and ground, which can cause serious burns or weld the metal object to the terminals.
»» Exposure to chemicals can degrade the sealing properties of materials used in the sealed relay
device.
»» It is not recommended to work on the system or connect or disconnect cables dur­ing periods
of lightning activity.
»» Before performing any of the following procedures, disconnect the power source from the DC
circuit.
»» Read the installation instructions before connecting the system to its power source.
»» This unit is intended for installation in restricted access areas. A restricted access area is
defined as an area that can be accessed only through the use of a special tool, lock and key, or
other means of security.
»» The device must be grounded. Never defeat the ground conductor or operate the equipment
in the absence of a suitably installed ground conductor.
»» This unit may have more than one power supply connection. All connections must be removed
to de-energize the unit.
»» If the switch is to be installed in a hazardous location, ensure that the DC power source is
located away from the vicinity of the switch.
»» The installation of the equipment must comply with all national and local electrical codes.
»» Explosion Hazard - The area must be known to be nonhazardous before servicing or replacing
any components.
»» Airflow Around The Switch Must Be Unrestricted. To Prevent The Switch From Overheating,
There Must Be The Following Minimum Clearances:
›› Top and Bottom: 2.0 in (50.8 mm)
›› Sides: 2.0 in (50.8 mm)
›› Front: 2.0 in (50.8 mm)
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 13
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.2. Installation Guidelines
»» The following guidelines are provided to optimize the device performance. Review the
guidelines before installing the device.
»» Make sure cabling is away from sources of electrical noise. Radios, power lines, and flu­orescent
lighting fixtures can interference with the device performance.
»» Make sure the cabling is positioned away from equipment that can damage the cables.
»» Operating environment is within the ranges listed range, see “Specifications” on page 1.
»» Relative humidity around the switch does not exceed 95 percent (non-condensing).
»» Altitude at the installation site is not higher than 10,000 feet.
»» In 10/100 and 10/100/1000 fixed port devices, the cable length from the switch to con­nected
devices can not exceed 100 meters (328 feet).
»» Make sure airflow around the switch and respective vents is unrestricted. Without proper
airflow the switch can overheat. To prevent performance degradation and dam­age to the
switch, make sure there is clearance at the top and bottom and around the exhaust vents.
2.3. Environment and Enclosure Guidelines
Review these environmental and enclosure guidelines before installation:
This equipment is intended for use in a Pollution Degree 2 industrial environment, in over-voltage
Category II applications (as defined in IEC publication 60664-1), at altitudes up to 9842 ft (3 km)
without derating.
This equipment is considered Group 1, Class A industrial equipment, according to IEC/ CISPR
Publication 11. Without appropriate precautions, there may be potential difficulties ensuring
electromagnetic compatibility in other environments due to conducted as well as radiated
disturbance.
This equipment is supplied as open-type equipment. It must be mounted within an enclo­sure
that is suitably designed for those specific environmental conditions that will be present and
appropriately designed to prevent personal injury resulting from accessibility to live parts. The
enclosure must have suitable flame-retardant properties to prevent or minimize the spread of
flame, complying with a flame-spread rating of 5VA, V2, V1, V0 (or equivalent) if nonmetallic. The
interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this
publication might contain additional information regarding spe­cific enclosure-type ratings that are
required to comply with certain product safety certifica­tions.
2.3.1 Connecting Hardware
In this instruction, it will explain how to find a proper location for your Modbus Gateways, and how
to connect to the network, hock up the power cable, and connect to the managed Ethernet switch.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 14
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.4. Verifying Switch Operation
Before installing the device in a rack or on a wall, power on the switch to verify that the switch
passes the power-on self-test (POST). To connect the cabling to the power source see “Power
Supply Installation” on page 15.
At startup (POST), the System LED blinks green, while the remaining LEDs are a solidy green.
Once the switch passes POST self-test, the System LED turns green. The other LEDs turn off and
return to their operating status. If the switch fails POST, the System LED switches to an amber
state.
After a successful self-test, power down the switch and disconnect the power cabling. The switch
is now ready for installation on its final location.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 15
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.5. Installing the Switch
2.5.1 Rack-Mounting
1. Align the rack mount brackets with the holes on the switch.
2. Secure the rack mount brackets with the provided screws.
Figure 2-1. Installing the Rack Mount Brackets
3. Align the switch with the posts on the rack cabinet.
4. Secure the switch with the provided screws.
Figure 2-2. Installing the Switch
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 16
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.6. Installing and Removing SFP Modules
Up to two fiber optic ports are available (dependent on model) for use in the switch. Refer to the
technical specifications for details.
The Gigabit Ethernet ports on the switch are 100/1000Base SFP Fiber ports, which require using
the 100M or 1G mini-GBIC fiber transceivers to work properly. ComNet provides completed
transceiver models for different distance requirement.
The concept behind the LC port and cable is quite straight forward. Suppose that you are
connecting devices I and II; contrary to electrical signals, optical signals do not require a cir­cuit in
order to transmit data. Consequently, one of the optical lines is used to transmit data from device
I to device II, and the other optical line is used transmit data from device II to device I, for fullduplex transmission.
Remember to connect the Tx (transmit) port of device I to the Rx (receive) port of device II, and
the Rx (receive) port of device I to the Tx (transmit) port of device II. If you make your own cable,
we suggest labeling the two sides of the same line with the same letter (A-to-A and B-to-B, or
A1-to-A2 and B1-to-B2).
2.6.1 Installing SFP Modules
To connect the fiber transceiver and LC cable, use the following guidelines:
1. Remove the dust plug from the fiber optic slot chosen for the SFP transceiver.
Figure 2-3. Removing the Dust Plug from an SFP Slot
Do not remove the dust plug from the SFP slot if you are not installing the trans­ceiver at this time.
The dust plug protects hardware from dust contamination.
2. Position the SFP transceiver with the handle on top, see the following figure.
3. Locate the triangular marking in the slot and align it with the bottom of the transceiver.
4. Insert the SFP transceiver into the slot until it clicks into place.
5. M
ake sure the module is seated correctly before sliding the module into the slot. A click sounds
when it is locked in place.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 17
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Handle
Figure 2-4. Installing an SFP Transceiver
If you are attaching fiber optic cables to the transceiver, continue with the following step.
Otherwise, repeat the previous steps to install the remaining SFP transceivers in the device.
6. Remove the protective plug from the SFP transceiver.
Do not remove the dust plug from the transceiver if you are not installing the fiber optic cable at
this time. The dust plug protects hardware from dust contamination.
7. Insert the fiber cable into the transceiver. The connector snaps into place and locks.
Figure 2-5. Attaching a Fiber Optic Cable to a Transceiver
8. R
epeat the previous procedures to install any additional SFP transceivers in the switch. The fiber
port is now setup.
2.6.2 Removing SFP Modules
To disconnect an LC connector, use the following guidelines:
1. Press down and hold the locking clips on the upper side of the optic cable.
2. Pull the optic cable out to release it from the transceiver.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 18
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Figure 2-6. Removing a Fiber Optic Cable to a Transceiver
3. Hold the handle on the transceiver and pull the transceiver out of the slot.
Handle
Figure 2-7. Removing an SFP Transceiver
Replace the dust plug on the slot if you are not installing a transceiver. The dust plug protects
hardware from dust contamination.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 19
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.7. Connecting the Switch to Ethernet Ports
2.7.1 RJ45 Ethernet Cable Wiring
For RJ45 connectors, data-quality, twisted pair cabling (rated CAT5 or better) is recom­mended.
The connector bodies on the RJ45 Ethernet ports are metallic and connected to the GND
terminal. For best performance, use shielded cabling. Shielded cabling may be used to provide
further protection.
Table 2-1. RJ45 Ethernet Wiring for Reference
Straight-thru Cable Wiring
Cross-over Cable Wiring
Pin 1
Pin 1
Pin 1
Pin 3
Pin 2
Pin 2
Pin 2
Pin 6
Pin 3
Pin 3
Pin 3
Pin 1
Pin 6
Pin 6
Pin 6
Pin 2
Figure 2-8. Ethernet Plug & Connector Pin Position
Maximum cable length: 100 meters (328 ft) for 10/100/1000Base-T
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 20
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.8. Connecting the Switch to Console Port
The industrial switch supports a secondary means of management. By connecting the RJ45 to
RS232 serial cable between a COM port on your PC (9-pin D-sub female) and the switch’s RJ45
(RJ45) port, a wired connection for management can be established.
To terminal or PC
To console port
Figure 2-9. Serial Console Cable
5
1
9
6
Figure 2-10. DB 9 Pin Position
Table 2-2. Pin Assignment
DB9 Connector
RJ45 Connector
NC
1 Orange/White
NC
2 Orange
2
3 Green/White
NC
4 Blue
5
5 Blue/White
3
6 Green
NC
7 Brown/White
NC
8 Brown
Figure 2-11. Pin Assignment
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 21
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.9. Power Supply Installation
2.9.1 Overview
Power down and disconnect the power cord before servicing or wiring the switch.
»» Do not disconnect modules or cabling unless the power is first switched off.
»» The device only supports the voltage outlined in the type plate. Do not use any other power
components except those specifically designated for the switch device.
»» Disconnect the power cord before installation or cable wiring.
The switches can be powered by using the same DC source used to power other devices. A DC
voltage range of 12 to 48 VDC (Non PoE) or 48 VDC (PoE) must be applied between the V1+
terminal and the V1- terminal (PW1), see the following illustrations. A Class 2 power supply is
required to maintain a UL60950 panel listing. The chassis ground screw terminal should be tied to
the panel or chassis ground. A redundant power configuration is supported through a secondary
power supply unit to reduce network down time as a result of power loss.
Dual power inputs are supported and allow you to connect a backup power source.
Single DC Power
P2 P1
Redundant DC Power
P2 P1
Chassis
GND
(pane)
Chassis
GND
(pane)
One DC Supply
Dual DC Supplies
Figure 2-12. Power Wiring for Managed Ethernet Switch
2.9.2 Considerations
Take into consideration the following guidelines before wiring the device:
»» The Terminal Block (CN1) is suitable for 12-24 AWG (3.31-0.205 mm2). Torque value 7 lb/in.
»» The cross sectional area of the earthing conductors shall be at least 3.331 mm2.
»» Calculate the maximum possible current for each power and common wire. Make sure the
power draw is within limits of local electrical code regulations.
»» For best practices, route wiring for power and devices on separate paths.
»» Do not bundle together wiring with similar electrical characteristics.
»» Make sure to separate input and output wiring.
»» Label all wiring and cabling to the various devices for more effective management and
servicing.
Routing communications and power wiring through the same conduit may cause signal
interference. To avoid interference and signal degradation, route power and communications
wires through separate conduits.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 22
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.9.3 Grounding the Device
»» Do not disconnect modules or cabling unless the power is first switched off.
The device only supports the voltage outlined in the type plate. Do not use any other power
components except those specifically designated for the switch device.
»» Before connecting the device properly ground the device. Lack of a proper ground­ing setup
may result in a safety risk and could be hazardous.
»» Do not service equipment or cables during periods of lightning activity.
»» Do not service any components unless qualified and authorized to do so.
»» Do not block air ventilation holes.
Electromagnetic Interference (EMI) affects the transmission performance of a device. By properly
grounding the device to earth ground through a drain wire, you can setup the best possible noise
immunity and emissions.
Console
Drain Wire with Lug
Connection to
Grounding Point
Figure 2-13. Grounding Connection
By connecting the ground terminal by drain wire to earth ground the switch and chassis can be
ground.
Before applying power to the grounded switch, it is advisable to use a volt meter to ensure there
is no voltage difference between the power supply’s negative output terminal and the grounding
point on the switch.
2.9.4 Wiring a Relay Contact
The following section details the wiring of the relay output. The terminal block on the managed
Ethernet switch is wired and then installed onto the terminal receptor located on the managed
Ethernet switch.
P-Fail
Figure 2-14. Terminal Receptor: Relay Contact
The terminal receptor includes a total of three pins.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 23
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.9.5 Wiring the Power Inputs
»» Do not disconnect modules or cabling unless the power is first switched off. The device only
supports the voltage outlined in the type plate. Do not use any other power components
except those specifically designated for the switch device.
Power down and disconnect the power cord before servicing or wiring the switch.
There are two power inputs for normal and redundant power configurations. The power input 2 is
used for wiring a redundant power configuration. See the following for terminal block connector
views.
PWR2
PWR1
V2- V2+ V1- V1+
Figure 2-15. Terminal Receptor: Power Input Contacts
To wire the power inputs:
Make sure the power is not connected to the switch or the power converter before proceed­ing.
1. Insert a small flat-bladed screwdriver in the V1+/V1- wire-clamp screws, and loosen the screws.
2. Insert the negative/positive DC wires into the V+/V- terminals of PW1. If setting up power
redundancy, connect PW2 in the same manner.
3. Tighten the wire-clamp screws to secure the DC wires in place.
PWR1
Loosening Wire-clamp
Screws
Installing
DC Wires
PWR2
Securing Wire-clamp
Screws
Figure 2-16. Installing DC Wires in a Terminal Block
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 24
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
2.10. Reset Button
Reset configuration to factory default
Press and hold Reset button for 5 seconds.
System reboot
Press and hold Reset button for 2 seconds.
Do NOT power off the Ethernet switch when loading default settings.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 25
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
3.0 Setup
3.1. First Time Setup
3.1.1 Overview
The Industrial Ethernet Managed Switch is a configurable device that facilitates the intercon­
nection of Ethernet devices on an Ethernet network. This includes computers, operator interfaces,
I/O, controllers, RTUs, PLCs, other switches/hubs or any device that supports the standard IEEE
802.3 protocol.
This switch has all the capabilities of a store and forward Ethernet switch plus advanced
management features such as SNMP, RSTP and port mirroring. This manual details how to
configure the various management parameters in this easy to use switch.
3.1.2 Introduction
To take full advantage of all the features and resources available from the switch, it must be
configured for your network.
The switch implements Rapid Spanning Tree Protocol (RSTP) and Simple Network Man­agement
Protocol (SNMP) to provide most of the services offered by the switch. Rapid Spanning Tree
Protocol allows managed switches to communicate with each other to ensure that there exists only
one active route between each pair of network nodes and pro­vides automatic failover to the next
available redundant route. A brief explanation of how RSTP works is given in the Spanning Tree
section.
The switch is capable of communicating with other SNMP capable devices on the network to
exchange management information. This statistical/derived information from the network is saved
in the Management Information Base (MIB) of the switch. The MIB is divided into several different
information storage groups. These groups will be elaborated in detail in the Management and
SNMP information section of this document. The switch implements Inter­net Group Management
Protocol (IGMP) to optimize the flow of multicast traffic on your net­work.
The switch supports both port-based and tag-based Virtual LANs for flexible integration with
VLAN-aware networks with support for VLAN-unaware devices.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 26
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
3.1.3 Administrative Interface Access
There are several administrative interfaces to the switch:
1. A
graphical web interface accessible via the switch’s built-in web server. Both HTTP and secure
HTTPS with SSL are supported.
This is the recommended method for managing the switch.
2. A terminal interface via the RS232/USB port or over the network using telnet or Secure Shell
(SSH).
3. An SNMP interface can be used to read/write many settings.
4. C
ommand Line Interface (CLI) can be used to read/write most settings. Initial setup must be
done using an Ethernet connection (recommended) or the serial port.
3.1.4 Using the Graphical (Web) Interface
The graphical interface is provided via a web server in the switch and can be accessed via a web
browser such as Opera, Mozilla, or Internet Explorer.
JavaScript must be supported and enabled in your browser for the graphical inter­face to work
correctly.
HTTP and HTTPS (secure HTTP) are supported for access to the web server. By default, both
protocols are enabled. Either or both may be disabled to secure the switch. (See the Remote
Access Security topic in this section.)
To access the graphical interface, enter a URL like HTTP://192.168.10.1 in your browser’s address
bar. Replace “http” with “https” to use secure http and replace “192.168.10.1” with your switch’s IP
address if you’ve changed it from the factory default.
The web server in the switch uses a signed security certificate. When you access the server via
https, you may see a warning dialog indicating that the certificate was signed by an unknown
authority. This is expected and to avoid this message in the future you can choose to install the
certificate on your computer.
This manual describes and depicts the web user interface in detail. The terminal interface is not
specifically shown but is basically the same.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 27
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
3.1.5 Configuring the Switch for Network Access
To control and monitor the switch via the network, it must be configured with basic network
settings, including an IP address and subnet mask. Refer to the quick start guide in Section 1 for
how to initially access your switch.
To configure the switch for network access, select [Add Menu Address Here] to reach the System
Settings menu. The settings in this menu control the switch’s general network con­figuration.
»» DHCP Enabled/Disabled: The switch can automatically obtain an IP address from a server
using the Dynamic Host Configuration Protocol (DHCP). This can speed up initial set up, as the
network administrator does not have to find an open IP address.
»» IP Address and subnet mask configuration: The IP address for the switch can be changed to a
user-defined address along with a customized subnet mask to separate subnets.
Advanced users can set the IP address to 0.0.0.0 to disable the use of an IP address for additional
security. However, any features requiring an IP address (i.e., web interface, etc.) will no longer be
available.
»» Default Gateway Selection: A Gateway Address is chosen to be the address of a router that
connects two different networks. This can be an IP address or a Fully Qualified Domain Name
(FQDN) such as “domainname.org”.
»» NTP Server: The IP address or domain name of an NTP (Network Time Protocol) server from
which the switch may retrieve the current time at startup. Please note that using a domain
name requires that at least one domain name server be configured.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 28
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
3.1.6 Configuring the Ethernet Ports
The switch comes with default port settings that should allow you to connect to the Ethernet Ports
with out any necessary configuration. Should there be a need to change the name of the ports,
negotiation settings or flow control settings, you can do this in the Port Configura­tion menu.
Access this menu by selecting Setup from the Main menu, and then selecting Main Settings.
»» Port Name: Each port in the managed switch can be identified with a custom name. Specify a
name for each port here.
»» Admin: Ports can be enabled or disabled in the managed switch. For ports that are dis­
abled, they are virtually non-existent (not visible in terms of switch operation or spanning tree
algorithm). Choose to enable or disable a port by selecting Enabled or Disabled, respectively.
»» Negotiation: All copper ports and gigabit fiber ports in the managed switch are capable of
autonegotiation such that the fastest bandwidth is selected. Choose to enable auto-negotiation
or use fixed settings. 100Mbps Fiber ports are Fixed speed only.
»» Speed/Duplex/Flow Control: The managed switch accepts three local area network Ethernet
Standards. The first standard, 10BASE-T, runs 10Mbps with twisted pair Ether­net cable
between network interfaces. The second local area network standard is 100BASE-T, which
runs at 100Mbps over the same twisted pair Ethernet cable. Lastly, there is 100BASE-F, which
enables fast Ethernet (100Mbps) over fiber.
These options are available:
»» 10h–10 Mbps, Half Duplex
»» 10f –10 Mbps, Full Duplex
»» 100h–100 Mbps, Half Duplex
»» 100f –100 Mbps, Full Duplex
»» 1000f–1000 Mbps, Full Duplex
On managed switches with gigabit combination ports, those ports with have two rows, a standard
row of check boxes and a row labeled “SFP” with radio buttons. The SFP setting independently
sets the speed at which a transceiver will operate if one is plugged in. Other­wise, the switch will
use the fixed Ethernet port and the corresponding settings for it.
When 100f is selected for the SFP of a gigabit combination port, the corresponding fixed
Ethernet jack will be disabled unless it is changed back to 1000F.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 29
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
3.2. Command Line Interface Configuration
3.2.1 Introduction to Command-Line Interface (CLI)
The command-line interface (CLI) is constructed with an eye toward automation of CLI-based
configuration. The interaction is modeled on that used in many Internet protocols such as Telnet,
FTP, and SMTP. After each command is entered and processed, the switch will issue a reply that
consists of a numeric status code and a human-readable explanation of the status.
The general format of commands is:
section parameter [value]
where:
»» section is used to group parameters.
»» parameter will specify the parameter within the section. For example, the network section will
have parameters for DHCP, IP address, subnet mask, and default gate­way.
»» value is the new value of the parameter. If value is omitted, the current value is dis­played.
Please note that new values will not take effect until explicitly committed.
Sections and parameter names are case sensitive (e.g., “Network” is not the same as “net­work”).
Any commands in the CLI Commands section of this chapter, with the exception of the global
commands, must be prefaced with the name of the section they are in. For example, to change
the IP address of the switch, you would type: network address <newIP>
3.2.2 Accessing the CLI
To access the CLI interface, establish Ethernet or serial connectivity to the switch. To connect by
Ethernet, open a command prompt window and type:
telnet <switchip> (where <switchip> is the IP address of the switch)
At the login prompt, type “cli” for the username and “admin” for the password. The switch will
respond with “Managed switch configuration CLI ready”.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 30
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
3.3. Web Browser Configuration
The switch has an HTML based user interface embedded in the flash memory. The interface offers
an easy to use means to manage basic and advanced switch functions. The interface allows for
local or remote switch configuration anywhere on the network.
The interface is designed for use with [Internet Explorer (6.0), Chrome, Firefox].
3.3.1 Preparing for Web Configuration
The interface requires the installation and connection of the switch to the existing network. A
PC also connected to the network is required to connect to the switch and access the inter­face
through a web browser. The required networking information is provided as follows:
»» IP address: 192.168.10.1
»» Subnet mask: 255.255.255.0
»» Default gateway: 192.168.10.254
»» User name: admin
»» Password: admin
3.3.2 System Login
Once the switch is installed and connected, power on the switch. The following information guides
you through the logging in process.
1. Launch your web browser on the PC.
2. In the browser’s address bar, type the switch’s default IP address (192.168.10.1). The login screen
displays.
3. Enter the user default name and password (admin / admin).
4. Click OK on the login screen to log in. The main interface displays.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 31
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.0. Switch Management
4.1. Log In
To access the login window, connect the device to the network, see “Connecting the Switch to
Ethernet Ports” on page 13. Once the switch is installed and connected, power on the switch see
the following procedures to log into your switch.
When the switch is first installed, the default network configuration is set to DHCP enabled. You
will need to make sure your network environment supports the switch setup before connecting it
to the network.
1. Launch your web browser on a computer.
2. In the browser’s address bar type in the switch’s default IP address (192.168.10.1). The login
screen displays.
3. Enter the default user name and password (admin/admin) to log into the management interface.
You can change the default password after you have successfully logged in.
4. Click Login to enter the management interface.
Figure 4-1. Login Screen
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 32
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.2. Recommended Practices
One of the easiest things to do to help increase the security posture of the network infrastructure
is to implement a policy and standard for secure management. This practice is an easy way to
maintain a healthy and secure network.
After you have performed the basic configurations on your switches, the following is a
recommendation which is considered best practice policy.
4.2.1 Changing Default Password
In keeping with good management and security practices, it is recommended that you change the
default password as soon as the device is functioning and setup correctly. The following details
the necessary steps to change the default password.
To change the password:
1. Navigate to Tools > User Account.
2. From the User drop-down menu, select the Admin (default) account.
3. In the User Name field, enter admin for this account. It is not necessary to change the user
name, however, a change in the default settings increases the security settings.
4. In the Password field, type in the new password. Re-type the same password in the Retype
Password field.
5. Click Apply to change the current account settings.
Figure 4-2. Changing a Default Password
After saving all the desired settings, perform a system save (Tools > Save Configura­tion). The
changes are saved.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 33
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.3. Monitoring
4.3.1 Device Information
The Device Information menu lists information, such as: System Name, System Location, MAC
Address, Firmware version, and more, pertaining to the system. The information is for review only.
To modify the device information, see the respective item within the user interface.
To access this page, click Monitoring > Device Information.
Figure 4-3. Monitoring > Device Information
Table 4-1. Monitoring > Device Information
Item
Description
System Name
Click Switch to enter the system name: up to 128 alphanumeric characters (default is
Switch).
System Location Click Default to enter the location: up to 256 alphanumeric characters (default is Default).
System Contact
Click Default to enter the contact person: up to 128 alphanumeric characters (default is
Default).
MAC Address
Displays the MAC address of the switch.
IP Address
Displays the assigned IP address of the switch.
Subnet Mask
Displays the assigned subnet mask of the switch.
Gateway
Displays the assigned gateway of the switch.
Loader Version
Displays the current loader version of the switch.
Loader Date
Displays the current loader build date of the switch.
Firmware Version Displays the current firmware version of the switch.
Firmware Date
Displays the current firmware build date of the switch.
System Object ID Displays the base object ID of the switch.
System Up Time
Displays the time since the last switch reboot.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 34
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.3.2 Logging Message
The Logging Message Filter page allows you to enable the display of logging message filter. To
access this page, click Monitoring > Logging Message.
Figure 4-4. Monitoring > Logging Message
Table 4-2. Monitoring > Logging Message
Item
Description
Target
Click the drop-down menu to select a target to store the log messages.
Buffered: Store log messages in RAM. All log messages are cleared after system reboot.
File: Store log messages in a file.
Severity
The setting allows you to designate a severity level for the Logging Message Filter function.
Click the drop-down menu to select the severity level target setting.
The level options are:
emerg: Indicates system is unusable. It is the highest level of severity.
alert: Indicates action must be taken immediately.
crit: Indicates critical conditions.
error: Indicates error conditions.
warning: Indicates warning conditions.
notice: Indicates normal but significant conditions.
info: Indicates informational messages.
debug: Indicates debug-level messages.
Category
Click the drop-down menu to select the category level target setting.
View
Click View to display all Logging Information and Logging Message information.
Refresh Click Refresh to update the screen.
Clear
buffered
messages
Click Clear buffered messages to clear the logging buffer history list.
The ensuing table for Logging Information table settings are informational only: Target, Severity
and Category.
The ensuing table for Logging Message table settings are informational only: No., Time Stamp,
Category, Severity and Message.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 35
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.3.3 Port Monitoring
Port Network Monitor is a bandwidth and network monitoring tool for the purpose of capturing
network traffic and measuring of network throughput. The monitoring functionality includes listing
of port statistics as well as port utilization.
Port Statistics
To access this page, click Monitoring > Port Monitoring > Port Statistics.
Figure 4-5. Monitoring > Port Monitoring > Port Statistics
Table 4-3. Monitoring > Port Monitoring > Port Statistics
Item
Description
Port
Click the drop-down menu to select a port and its captured statistical setting values.
Clear
Click Clear to clear the counter selections.
The ensuing table for IF MIB Counters settings are informational only: ifInOctets, ifInUcast-Pkts,
ifInNUcastPkts, ifInDiscards, ifOutOctets, ifOutUcastPkts, ifOutNUcastPkts, ifOutDis-cards,
ifInMulticastPkts, ifInBroadcastPkts, ifOutMulticastPkts and ifOutBroadcastPkts.
The ensuing table for Ether-Like MIB Counters settings are informational only:
dot3StatsAlignmentErrors, dot3StatsFCSErrors, dot3StatsSingleCollisionFrames,
dot3StatsMultipleCollisionFrames, dot3StatsDeferredTransmissions, dot3StatsLateCollisions,
dot3StatsExcessiveCollisions, dot3StatsFrameTooLongs, dot3StatsSymbolErrors,
dot3ControlInUnknownOpcodes, dot3InPauseFrames and dot3OutPauseFrames.
The ensuing table for Rmon MIB Counters settings are informational only: etherStatsDropEvents, etherStatsOctets, etherStatsPkts, etherStatsBroadcastPkts, etherStatsMulti-castPkts,
etherStatsCRCAlignErrors, etherStatsUnderSizePkts, etherStatsOverSizePkts, etherStatsFragments,
etherStatsJabbers, etherStatsCollisions, etherStatsPkts64Octets, etherStatsPkts65to127Octets,
etherStatsPkts128to255Octets, etherStatsPkts256to511Octets, etherStatsPkts512to1023Octets and
etherStatsPkts1024to1518Octets.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 36
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Port Utilization
To access this page, click Monitoring > Port Monitoring > Port Utilization.
Figure 4-6. Monitoring > Port Monitoring > Port Utilization
Table 4-4. Monitoring > Port Monitoring > Port Utilization
Item
Description
Refresh period
Click the drop-down menu to select and designate a period (second intervals) to refresh
the information (TX and RX) listings.
IFG
Click the drop-down menu to enable or disable the Interframe Gap (IFG) statistic.
4.3.4 Link Aggregation
The Link Aggregation function provides LAG information for each trunk. It displays membership
status, link state and membership type for each port.
To access this page, click Monitoring > Link Aggregation.
The ensuing table for Link Aggregation Group Status settings are informational only: LAG, Name,
Type, Link State, Active Member and Standby Member.
The ensuing table for LACP Information settings are informational only: LAG, Port, Partner-SysId,
PnKey, AtKey, Sel, Mux, Receiv, PrdTx, AtState and PnState.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 37
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.3.5 LLDP Statistics
The LLDP Statistics page displays the LLDP statistics.
To access this page, click Monitoring > LLDP Statistics.
Figure 4-7. Monitoring > LLDP Statistics
Table 4-5. Monitoring > LLDP Statistics
Item
Description
Clear
Click Clear to reset LLDP Statistics of all the interfaces.
Refresh
Click Refresh to update the data on the screen with the present state of the data in the switch.
The ensuing table for LLDP Global Statistics settings are informational only: Insertions, Deletions,
Drops and Age Outs.
The ensuing table for LLDP Port Statistics settings are informational only: Port, TX Frames (Total),
RX Frames (Total, Discarded and Errors), RX TLVs (Discarded and Unrecognized) and RX Ageouts
(Total).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 38
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.3.6 IGMP Statistics
The IGMP Statistics function displays statistical package information for IP multicasting. To access
this page, click Monitoring > IGMP Statistics.
Figure 4-8. Monitoring > IGMP Statistics
Table 4-6. Monitoring > IGMP Statistics
Item
Description
Clear
Click Clear to refresh IGMP Statistics of all the interfaces.
Refresh
Click Refresh to update the data on the screen with the present state of the data in the
switch.
The ensuing table for IGMP Statistics settings are informational only: Total RX, Valid RX, Invalid
RX, Other RX, Leave RX, Report RX, General Query RX, Special Group Query RX, Special Group &
Source Query RX, Leave TX, Report TX, General Query TX, Special Group Query TX and Special
Group & Source Query TX.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 39
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.4. System
4.4.1 IP Settings
The IP Settings menu allows you to select a static or DHCP network configuration. The Static
displays the configurable settings for the static option.
To access this page, click System > IP Settings.
Figure 4-9. System > IP Settings
Table 4-7. System > IP Settings
Item
Description
Mode
Click the radio button to select the IP Address Setting mode: Static or DHCP.
IP Address
Enter a value to specify the IP address of the interface. The default is 192.168.10.1.
Subnet
Mask Enter a value to specify the IP subnet mask for the interface. The default is
255.255.255.0.
Gateway
Enter a value to specify the default gateway for the interface. The default is 192.168.1.254.
DNS Server 1
Enter a value to specify the DNS server 1 for the interface. The default is 168.95.1.1.
DNS Server 2
Enter a value to specify the DNS server 2 for the interface. The default is 168.95.192.1.
Apply
Click Apply to save the values and update the screen.
The ensuing table for IP Address Information settings are informational only: DHCP State, Static IP
Address, Static Subnet Mask, Static Gateway, Static DNS Server 1 and Static DNS Server 2.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 40
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.4.2 DHCP Client Option 82
The DHCP Client Option 82 configurable Circuit ID and Remote ID feature enhances validation
security by allowing you to select naming choices suboptions. You can select a switch-configured
hostname or specify an ASCII test string for the remote ID. You can also configure an ASCII text
string to override the circuit ID.
To access this page, click System > DHCP Client Option 82.
Figure 4-10. System > DHCP Client Option 82
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 41
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-8. System > DHCP Client Option 82
Item
Description
Mode
Click the radio button to enable or disable the DHCP Client Option 82 mode.
Circuit ID Format Click the drop-down menu to set the ID format: String, Hex, User Definition.
Circuit ID String
Enter the string ID of the corresponding class.
Circuit ID Hex
Enter the hex string of the corresponding class.
Circuit ID UserDefine
Enter the user definition of the corresponding class.
Remote ID Format Click the drop-down menu to set the Remote ID format: String, Hex, User Definition.
Remote ID String Enter the remote string ID of the corresponding class.
Remote ID Hex
Enter the remote hex string of the corresponding class.
Remote ID User- Enter the remote user definition of the corresponding class.
Define
Apply
Click Apply to save the values and update the screen.
The ensuing table for DHCP Client Option 82 Information table settings are informational only:
Status, Circuit ID Format, Circuit ID String, Circuit ID Hex, Circuit ID User-Define, Remote ID
Format, Remote ID String, Remote ID Hex and Remote ID User-Define.
4.4.3 DHCP Auto Provision
The DHCP Auto Provision feature allows you to load configurations using a server with DHCP
options. Through the remote connection, the switch obtains information from a configuration file
available through the TFTP server.
To access this page, click System > DHCP Auto Provision.
Figure 4-11. System > DHCP Auto Provision
Table 4-9. System > DHCP Auto Provision
Item
Description
Status
Select the radio button to enable or disable the DHCP Auto Provisioning Setting.
Apply
Click Apply to save the values and update the screen.
The ensuing table for DHCP Auto Provision Information settings are informational only: Status
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 42
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.4.4 IPv6 Settings
To access this page, click System > IPv6 Settings.
Figure 4-12. System > IPv6 Settings
Table 4-10. System > IPv6 Settings
Item
Description
Auto Configuration
Select the radio button to enable or disable the IPv6.
IPv6 Address
Enter the IPv6 address for the system.
Gateway
Enter the gateway address for the system.
DHCPv6 Client
Enter the DHCPv6 address for the system
Apply
Click Apply to save the values and update the screen.
The ensuing table for IPv6 Information settings are informational only: Auto Configuration, IPv6 In
Use Address, IPv6 In Use Router, IPv6 Static Address, IPv6 Static Router and DHCPv6 Client.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 43
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.4.5 Management VLAN
By default the VLAN is the management VLAN providing communication with the switch
management interface.
To access this page, click System > Management VLAN.
Figure 4-13. System > Management VLAN
Table 4-11. System > Management VLAN
Item
Description
Management VLAN
Click the drop-down menu to select a defined VLAN.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Management VLAN State are informational only: Management VLAN.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 44
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.4.6 System Time
To access this page, click System > System Time.
Figure 4-14. System > System Time
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 45
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-12. System > System Time
Item
Description
Enable SNTP
Click the radio button to enable or disable the SNTP.
SNTP/NTP Server
Address
Enter the address of the SNTP server. This is a text string of up to 64 characters
containing the encoded unicast IP address or hostname of a SNTP server. Unicast
SNTP requests will be sent to this address. If this address is a DNS hostname,
then that hostname should be resolved into an IP address each time a SNTP
request is sent to it.
SNTP Port
Enter the port on the server to which SNTP requests are to be sent. Allowed
range is 1 to 65535 (default: 123).
Manual Time
Click the drop-down menus to set local date and time of the system.
Time Zone
Click the drop-down menu to select a system time zone.
Daylight Saving Time
Click the drop-down menu to enable or disable the daylight saving time settings.
Daylight Saving Time
Offset
Enter the offsetting variable in seconds to adjust for daylight saving time.
Recurring From
Click the drop-down menu to designate the start date and time for daylight
saving time.
Recurring To
Click the drop-down menu to designate the end date and time for daylight saving
time.
Non-Recurring From
Click the drop-down menu to designate a start date and time for a non­recurring
daylight saving time event.
Non-Recurring To
Click the drop-down menu to designate the end date and time for a non­recurring
daylight saving time event.
Apply
Click Apply to save the values and update the screen.
The ensuing table for System Time Information settings are informational only: Current Date/Time,
SNTP, SNTP Server Address, SNTP Server Port, Time zone, Daylight Saving Time, Daylight Saving
Time Offset, From and To.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 46
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.5. L2 Switching
4.5.1 Port Configuration
Port Configuration describes how to use the user interface to configure LAN ports on the switch.
To access this page, click L2 Switching > Port Configuration.
Figure 4-15. L2 Switching > Port Configuration
Table 4-13. L2 Switching > Port Configuration
Item
Description
Port
Click the drop-down menu to select the port for the L2 Switch setting.
Enabled
Click the radio-button to enable or disable the Port Setting function.
Speed
Click the drop-down menu to select the port speed: Auto, Auto-10M, Auto-100M, Auto1000M, Auto-10/100M, 10M, 100M, or 1000M.
Duplex
Click the drop-down menu to select the duplex setting: Half or Full.
Flow Control
Click the radio button to enable or disable the flow control function.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Port Status settings are informational only: Port, Edit (click to enter
description), Enable State, Link Status, Speed, Duplex, FlowCtrl Config and FlowCtrl Status.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 47
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.5.2 Port Mirror
Port mirroring function allows the sending of a copy of network packets seen on one switch port
to a network monitoring connection on another switch port. Port mirroring can be used to analyze
and debug data or diagnose errors on a network or to mirror either inbound or outbound traffic
(or both).
There are no preset values in the Port Mirror. The displayed values do not represent the actual
setting values.
To access this page, click L2 Switching > Port Mirror.
Figure 4-16. L2 Switching > Port Mirror
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 48
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-14. L2 Switching > Port Mirror
Item
Description
Session ID
Click the drop-down menu to select a port mirroring session from the list. The
number of sessions allowed is platform specific.
Monitor session state Click the drop-down menu to enable or disable the session mode for a selected
session ID.
Destination Port
Click the drop-down menu to select the destination port and receive all the traffic
from configured mirrored port(s).
Allow-ingress
Click the drop-down menu to enable or disable the Allow-ingress function.
Sniffer RX Ports
Enter the variable to define the RX port.
Sniffer TX Ports
Enter the variable to define the TX port.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Mirror Status settings are informational only: Session ID, Destination Port,
Ingress State, Source TX Port and Source RX Port.
4.5.3 Link Aggregation
Link Aggregation is a method for combining multiple network connections in parallel in order to
increase throughput beyond the capability of a single connection, and to provide redundancy in
case one of the links should fail.
Load Balance
The Load Balancing page allows you to select between a MAC Address or IP/MAC Address
algorithm for the even distribution of IP traffic across two or more links.
To access this page, click L2 Switching > Link Aggregation > Load Balance.
Figure 4-17. L2 Switching > Link Aggregation > Load Balance
Table 4-15. L2 Switching > Link Aggregation > Load Balance
Item
Description
Load Balance
Algorithm
Select the radio button to select the Load Balance Setting: MAC Address or IP/MAC
Address.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Load Balance Information settings are informational only: Load Balance
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 49
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Algorithm.
LAG Management
Link aggregation is also known as trunking. It is a feature available on the Ethernet gateway and is
used with Layer 2 Bridging. Link aggregation allows for the logical merging of multiple ports into
a single link.
To access this page, click L2 Switching > Link Aggregation > LAG Management.
Figure 4-18. L2 Switching > Link Aggregation > LAG Management
Table 4-16. L2 Switching > Link Aggregation > LAG Management
Item
Description
LAG
Click the drop-down menu to select the designated trunk group: Trunk 1 ~8.
Name
Enter an entry to specify the LAG name.
Type
Click the radio button to specify the type mode: Static or LACP.
Ports
Click the drop-down menu to select designated ports: FE1-8 or GE1-2.
Apply
Click Apply to save the values and update the screen.
The ensuing table for LAG Management Information settings are informational only: LAG, Name,
Type, Link State, Active Member, Standby Member, Edit (click to modify the settings) and Clear
(click to load default settings).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 50
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
LAG Port Settings
The LAG Port Settings page allows you to enable or disable, set LAG status, speed and flow
control functions.
In this example we will configure a LAG between the following switches:
To access this page, click L2 Switching > Link Aggregation > LAG Port Settings.
Figure 4-19. L2 Switching > Link Aggregation > LAG Port Settings
Table 4-17. L2 Switching > Link Aggregation > LAG Port Settings
Item
Description
LAG Select
Click the drop-down menu to select a predefined LAG trunk definition: LAG 1-8.
Enabled
Click the radio button to enable or disable the LAG Port.
Speed
Click the drop-down menu to select the port speed: Auto, Auto-10M, Auto-100M, Auto1000M, Auto-10/100M, 10M, 100M, or 1000M.
Flow Control Click the radio button to enable or disable the Flow Control for the LAG Port.
Apply
Click Apply to save the values and update the screen.
The ensuing table for LAG Port Status settings are informational only: LAG, Description, Port Type,
Enable State, Link Status, Speed, Duplex, FlowCtrl Config and FlowCtrl Status.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 51
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
LACP Priority Settings
The LACP Priority Settings page allows you to configure the system priority for LACP.
To access this page, click L2 Switching > Link Aggregation > LACP Priority Settings.
Figure 4-20. L2 Switching > Link Aggregation > LACP Priority Settings
Table 4-18. L2 Switching > Link Aggregation > LACP Priority Settings
Item
Description
System Priority
Enter the value (1-65535) to designate the LACP system priority.
Apply
Click Apply to save the values and update the screen.
The ensuing table for LACP Information settings are informational only: System Priority.
LACP Port Settings
Link Aggregation Control Protocol (LACP) provides a method to control the bundling of several
physical ports together to form a single logical channel. By configuring the LACP function, the
switch can negotiate an automatic bundling of links by sending LACP packets to the peer device
(also implementing LACP).
To access this page, click L2 Switching > Link Aggregation > LACP Port Settings.
Figure 4-21. L2 Switching > Link Aggregation > LACP Port Settings
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 52
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-19. L2 Switching > Link Aggregation > LACP Port Settings
Item
Description
Port Select
Select a port for the LACP Port Settings. The listed available settings are: FE1-FE8, GE1-GE2.
However, the available settings are dependent on the connected LACP device and may not
be listed as displayed in the current figure.
Priority
Enter a variable (1 to 65535) to assign a priority to the defined port selec­tion.
Timeout
Click the radio button to select a long or short timeout period.
Mode
Click the radio button to select the setting mode: Active or Passive.
Active: Enables LACP unconditionally.
Passive: Enables LACP only when an LACP device is detected (default state).
Apply
Click Apply to save the values and update the screen.
The ensuing table for LACP Port Information settings are informational only: Port Name, Priority,
Timeout and Mode.
4.5.4 802.1Q VLAN
The 802.1Q VLAN feature allows for a single VLAN to support multiple VLANs. With the 802.1Q
feature you can preserve VLAN IDs and segregate different VLAN traffic.
The 802.1Q VLAN tag feature encapsulates the 802.1Q VLAN tagging within another 802.1Q
VLAN tag. The outer tag is assigned following the AP group, while the inner VLAN ID is assigned
dynamically by the AAA server.
VLAN Management
The management of VLANs is available through the VLAN Settings page. Through this page you
can add or delete VLAN listings and add a prefix name to an added entry.
To access this page, click L2 Switching > 802.1Q VLAN > VLAN Management.
Figure 4-22. L2 Switching > 802.1Q VLAN > VLAN Management
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 53
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-20. L2 Switching > 802.1Q VLAN > VLAN Management
Item
Description
VLAN list
Enter the name of the VLAN entry to setup.
VLAN Action
Click the radio button to add or delete the VLAN entry shown in the previous field.
VLAN Name Prefix
Enter the prefix to be used by the VLAN list entry in the previous field.
Apply
Click Apply to save the values and update the screen.
The ensuing table for VLAN Table settings are informational only: VLAN ID, VLAN Name, VLAN
Type and Edit (click to enter VLAN name).
PVID Settings
The PVID Settings page allows you to designate a PVID for a selected port, define the accepted
type and enable/disable the ingress filtering.
To access this page, click L2 Switching > 802.1Q VLAN > PVID Settings.
Figure 4-23. L2 Switching > 802.1Q VLAN > PVID Settings
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 54
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-21. L2 Switching > 802.1Q VLAN > PVID Settings
Item
Description
Port Select
Click the drop-down menu to select a port and edit its settings: FE1-FE8, GE1-GE2, or
Trunk1 - Trunk8.
PVID
Enter the VLAN ID you want assigned to untagged or priority tagged frames received
on this port. The value ranges 1 to 4094. The default is 1.
Accepted Type
Click the radio button to specify which frames to forward. Tag Only discards any
untagged or priority tagged frames. Untag Only discards any tagged frames.
All accepts all untagged and tagged frames.
Whichever you select, VLAN tagged frames are forwarded in accordance with the IEEE
802.1Q VLAN standard. The default is All.
Ingress Filtering
Click the radio button to specify how you want the port to handle tagged frames. If you
enable Ingress Filtering, a tagged frame will be discarded if this port is not a member
of the VLAN identified by the VLAN ID in the tag. If you select Disabled, all tagged
frames will be accepted. The default is Disabled.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Port VLAN Status settings are informational only: Port, Interface VLAN
Mode, PVID, Accept Frame Type and Ingress Filtering.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 55
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Port to VLAN
The Port to VLAN page allows you to add a port to a VLAN and select the related parameters.
To access this page, click L2 Switching > 802.1Q VLAN > Port to VLAN.
Figure 4-24. L2 Switching > 802.1Q VLAN > Port to VLAN
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 56
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-22. L2 Switching > 802.1Q VLAN > Port to VLAN
Item
Description
Port
Displays the assigned port to the entry.
Interface VLAN
Mode
Displays the assigned mode to the listed VLAN port.
Hybrid: Port hybrid model.
Access: Port hybrid model.
Trunk: Port hybrid model.
Tunnel: Port hybrid model.
Membership
Displays the assigned membership status of the port entry, options include: Forbidden,
Excluded Tagged or Untagged.
Apply
Click Apply to save the values and update the screen.
Port-VLAN Mapping
To access this page, click L2 Switching > 802.1Q VLAN > Port-VLAN Mapping.
The ensuing table for Port-VLAN Mapping Table settings are informational only: Port, Mode,
Administrative VLANs and Operational VLANs.
4.5.5 Q-in-Q
Q-in-Q is commonly referred as VLAN stacking in which VLANs are nested by adding two tags to
each frame instead of one. Network service provider and users both can use VLANs and makes it
possible to have more than the 4094 separate VLANs allowed by 802.1Q.
There are three ways in which a machine can be connected to a network carrying double-tagged
802.1ad traffic:
»» via a untagged port, where both inner and outer VLANs are handled by the switch or switches
(so the attached machine sees ordinary Ethernet frames);
»» via a single-tagged (tunnel) port, where the outer VLAN only is handled by the switch (so the
attached machine sees single-tagged 802.1Q VLAN frames); or
»» via a double-tagged (trunk) port, where both inner and outer VLANs are handled by the
attached machine (which sees double-tagged 802.1ad VLAN frames).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 57
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Global Settings
The Global Settings page allows you to set the outer VLAN Ethertype setting. To access this page,
click L2 Switching > Q-in-Q > Global Settings.
Figure 4-25. L2 Switching > Q-in-Q > Global Settings
Table 4-23. L2 Switching > Q-in-Q > Global Settings
Item
Description
Outer VLAN Ethertype
Enter the outer VLAN handled by the switch giving the attached machine a
single-tagged 802.1Q VLAN frame.
Apply
Click Apply to save the values and update the screen.
The ensuing table for QinQ Global Information settings are informational only: Outer VLAN
Ethertype.
Port Settings
The Port Settings page allows you to define the outer PVID and outer mode for a selected port.
To access this page, click L2 Switching > Q-in-Q > Port Settings.
Figure 4-26. L2 Switching > Q-in-Q > Port Settings
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 58
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-24. L2 Switching > Q-in-Q > Port Settings
Item
Description
Port Select
Enter the switch port (part of VLAN configuration) to configure the selection as a tunnel
port.
Outer PVID
Enter the Port VLAN ID (PVID) to assigned the native VLAN ID. All untagged traffic coming
in or out of the 802.1Q port is forwarded based on the PVID value
Outer Mode
Click the drop-down menu to select between UNI or NNI role.
UNI: Selects a user-network interface which specifies communication between the
specified user and a specified network.
NNI: Selects a network-to-network interface which specifies communication between two
specified networks.
Apply
Click Apply to save the values and update the screen.
The ensuing table for QinQ Port Information settings are informational only: Port, Outer PVID and
Outer Mode.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 59
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.5.6 GARP
The Generic Attribute Registration Protocol (GARP) is a local area network (LAN) protocol. The
protocol defines procedures for the registration and de-registration of attributes (network
identifiers or addresses) by end stations and switches with each other.
GARP Settings
To access this page, click L2 Switching > GARP > GARP Settings.
Figure 4-27. L2 Switching > GARP > GARP Settings
Table 4-25. L2 Switching > GARP > GARP Settings
Item
Description
Join Time
Enter a value to specify the time between the transmission of GARP PDUs registering
(or re-registering) membership for a VLAN or multicast group in centiseconds. Enter a
number between 6 and 600. An instance of this timer exists for each GARP participant for
each port.
Leave Time
Enter a value to specify the time to wait after receiving an unregister request for a VLAN
or multicast group before deleting the associated entry, in centiseconds. This allows
time for another station to assert registration for the same attribute in order to maintain
uninterrupted service. Enter a number between 12 and 3000. An instance of this timer
exists for each GARP participant for each port.
Leave All Time
Enter a value to specify the Leave All Time controls how frequently Leave All PDUs are
generated. A LeaveAll PDU indicates that all registrations will shortly be deregistered.
Participants will need to rejoin in order to maintain registration. The Leave All Period
Timer is set to a random value in the range of LeaveAllTime to 1.5*LeaveAllTime. The
timer is specified in centiseconds. Enter a number between 12 and 12000. An instance of
this timer exists for each GARP participant for each port.
Apply
Click Apply to save the values and update the screen.
The ensuing table for GARP Information settings are informational only: Join Time, Leave
Time and Leave All Time.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 60
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
GVRP Settings
The GVRP Settings page allows you to enable or disable the GVRP (GARP VLAN Registration
Protocol or Generic VLAN Registration Protocol) protocol which facilitates control of virtual local
area networks (VLANs) within a larger network.
To access this page, click L2 Switching > GARP > GVRP Settings.
Figure 4-28. L2 Switching > GARP > GVRP Settings
Table 4-26. L2 Switching > GARP > GVRP Settings
Item
Description
Status
Click to enable or disable the GARP VLAN Registration Protocol administrative mode for the
switch. The factory default is Disable.
Apply
Click Apply to save the values and update the screen.
The ensuing table for GVRP Information settings are informational only: GVRP.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 61
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.5.7 802.3az EEE
The 802.3az Energy Efficient Ethernet (EEE) innovative green feature reduces energy consumption
through intelligent functionality:
»» Traffic detection — Energy Efficient Ethernet (EEE) compliance
»» Inactive link detection
Inactive link detection function automatically reduces power usage when inactive links or devices
are detected.
To access this page, click L2 Switching > 802.3az EEE.
Figure 4-29. L2 Switching > 802.3az EEE
Table 4-27. L2 Switching > 802.3az EEE
Item
Description
Port Select
Enter the port to setup the EEE function.
State
Click Enabled or Disabled to set the state mode of the port select setting.
Apply
Click Apply to save the values and update the screen.
The ensuing table for EEE Enable Status settings are informational only: Port and EEE State.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 62
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.5.8 Multicast
Multicast forwarding allows a single packet to be forwarded to multiple destinations. The service is
based on L2 switch receiving a single packet addressed to a specific Multicast address. Multicast
forwarding creates copies of the packet, and transmits the packets to the relevant ports.
Multicast Filtering
The Multicast Filtering page allows for the definition of action settings when an unknown multicast
request is received. The options include: Drop, Flood, or Router Port.
To access this page, click L2 Switching > Multicast > Multicast Filtering.
Figure 4-30. L2 Switching > Multicast > Multicast Filtering
Table 4-28. L2 Switching > Multicast > Multicast Filtering
Item
Description
Unknown
Multicast Action
Select the configuration protocol: Drop, Flood, or Router Port, to apply for any unknown
multicast event.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Properties Information settings are informational only: Unknown Multicast
Action.
IGMP Snooping
IGMP Snooping is defined as the process of listening to Internet Group Management Protocol
(IGMP) network traffic. IGMP Snooping allows a network switch to listen in on the IGMP
conversation between hosts and routers and maintain a map of which links need which IP
multicast streams. Multicasts can be filtered from the links which do not need them in turn
controlling which ports receive specific multicast traffic.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 63
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
IGMP Settings
To access this page, click L2 Switching > Multicast > IGMP Snooping > IGMP Settings.
Figure 4-31. L2 Switching > Multicast > IGMP Snooping > IGMP Settings
Table 4-29. L2 Switching > Multicast > IGMP Snooping > IGMP Settings
Item
Description
IGMP Snooping
State
Select Enable or Disable to designate the IGMP Snooping State.
IGMP Snooping
Version
Select designate the IGMP Snooping Version: V2 or V3.
IGMP Snooping
Select Enable or Disable to setup the report suppression for IGMP Snooping.
Report Suppression
Apply
Click Apply to save the values and update the screen.
The ensuing table for IGMP Snooping Information settings are informational only: IGMP Snooping
State, IGMP Snooping Version and IGMP Snooping V2 Report Suppression.
The ensuing table for IGMP Snooping Table settings are informational only: Entry No., VLAN ID,
IGMP Snooping Operation State, Router Ports Auto Learn, Query Robustness, Query Interval
(sec.), Query Max Response Interval (sec.), Last Member Query count, Last Member Query Interval
(sec), Immediate Leave and Edit (click to modify the settings).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 64
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
IGMP Querier
IGMP Querier allows snooping to function by creating the tables for snooping. General queries
must be unconditionally forwarded by all switches involved in IGMP snooping.
To access this page, click L2 Switching > Multicast > IGMP Snooping > IGMP Querier.
Figure 4-32. L2 Switching > Multicast > IGMP Snooping > IGMP Querier
Table 4-30. L2 Switching > Multicast > IGMP Snooping > IGMP Querier
Item
Description
VLAN ID
Select the VLAN ID to define the local IGMP querier.
Querier State
Select Disable or Enable to configure the VLAN ID (IGMP Querier).
Querier Version
Select the querier version (V2 or V3) designated to the selected VLAN ID.
Apply
Click Apply to save the values and update the screen.
The ensuing table for IGMP Querier Status settings are informational only: VLAN ID, Querier State,
Querier Status, Querier Version and Querier IP.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 65
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
IGMP Static Groups
To access this page, click L2 Switching > Multicast > IGMP Snooping > IGMP Static Groups.
Figure 4-33. L2 Switching > Multicast > IGMP Snooping > IGMP Static Groups
Table 4-31. L2 Switching > Multicast > IGMP Snooping > IGMP Static Groups
Item
Description
VLAN ID
Select the VLAN ID to define IGMP static group.
Group IP Address
Enter the IP address assigned to the VLAN ID.
Member Ports
Enter the port numbers to associate with the static group.
Add
Click Add to add an IGMP group.
The ensuing table for IGMP Static Groups Status settings are informational only: VLAN ID, Group
IP Address, Member Ports and Modify.
Multicast Groups
To access this page, click L2 Switching > Multicast > IGMP Snooping > Multicast Groups.
The ensuing table for Multicast Groups settings are informational only: VLAN ID, Group IP
Address, Member Ports, Type and Life (Sec).
Router Ports
To access this page, click L2 Switching > Multicast > IGMP Snooping > Router Ports.
The ensuing table for Router Ports settings are informational only: VLAN ID, Port and Expiry Time
(Sec).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 66
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
MLD Snooping
The MLD Snooping page allows you to select the snooping status (enable or disable), the version
(v1 or v2) and the enabling/disabling of the report suppression for the MLD querier, which sends
out periodic general MLD queries and are forwarded through all ports in the VLAN.
MLD Settings
To access this page, click L2 Switching > Multicast > MLD Snooping > MLD Settings.
Figure 4-34. L2 Switching > Multicast > MLD Snooping > MLD Settings
Table 4-32. L2 Switching > Multicast > MLD Snooping > MLD Settings
Item
Description
MLD Snooping State
Select Enable or Disable to setup the MLD Snooping State.
MLD Snooping Version
Select the querier version (V1 or V2) designated to the MLD Snooping Version.
MLD Snooping Report
Suppression
Select Enable or Disable to designate the status of the report suppression.
Apply
Click Apply to save the values and update the screen.
The ensuing table for MLD Snooping Information settings are informational only: MLD Snooping
State, MLD Snooping Version and MLD Snooping V2 Report Suppression.
The ensuing table for MLD Snooping Table settings are informational only: Entry No., VLAN ID,
MLD Snooping Operation State, Router Ports Auto Learn, Query Robustness, Query Interval (sec.),
Query Max Response Interval (sec.), Last Member Query count, Last Member Query Interval (sec),
Immediate Leave and Edit (click to modify the settings).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 67
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
MLD Querier
The MLD Querier page allows you to select and enable/disable the MLD querier and define the
version (IGMPv1 or IGMPv2) when enabled.
To access this page, click L2 Switching > Multicast > MLD Snooping > MLD Querier.
Figure 4-35. L2 Switching > Multicast > MLD Snooping > MLD Querier
Table 4-33. L2 Switching > Multicast > MLD Snooping > MLD Querier
Item
Description
VLAN ID
Enter the VLAN ID to configure.
Querier State
Select Enable or Disable status on the selected VLAN. Enable: Enable IGMP Querier
Election. Disable: Disable IGMP Querier Election.
Querier Version Select the querier version (IGMPV1 or IGMPV2) designated to the MLD Querier function.
Apply
Click Apply to save the values and update the screen.
The ensuing table for MLD Querier Status settings are informational only: VLAN ID, Querier State,
Querier Status, Querier Version and Querier IP.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 68
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
MLD Static Group
The MLD Static Group page allows you to configure specified ports as static member ports.
To access this page, click L2 Switching > Multicast > MLD Snooping > MLD Static Group.
Figure 4-36. L2 Switching > Multicast > MLD Snooping > MLD Static Group
Table 4-34. L2 Switching > Multicast > MLD Snooping > MLD Static Group
Item
Description
VLAN ID
Enter the VLAN ID to define the local MLD Static Group.
Group IP Address
Enter the IP address associated with the static group.
Member Ports
Enter the ports designated with the static group.
Add
Click Add to add a MLD static group.
The ensuing table for MLD Static Groups Status settings are informational only: VLAN ID, Group IP
Address, Member Ports and Modify.
Multicast Groups
To access this page, click L2 Switching > Multicast > MLD Snooping > Multicast Groups.
The ensuing table for Multicast Groups settings are informational only: ID, Group IP Address,
Member Ports, Type and Life (Sec).
Router Ports
To access this page, click L2 Switching > Multicast > MLD Snooping > Router Ports.
The ensuing table for Router Ports settings are informational only: VLAN ID, Port and Expiry Time
(Sec).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 69
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.5.9 Jumbo Frame
Jumbo frames are frames larger than the standard Ethernet frame size of 1518 bytes. The Jumbo
Frame function allows the configuration of Ethernet frame size.
To access this page, click L2 Switching > Jumbo Frame.
Figure 4-37. L2 Switching > Jumbo Frame
Table 4-35. L2 Switching > Jumbo Frame
Item
Description
Jumbo Frame Enter the variable in bytes (1518 to 9216) to define the jumbo frame size.
(Bytes)
Apply
Click Apply to save the values and update the screen.
The ensuing table for Jumbo Frame Config settings are informational only: Jumbo Frame (Bytes).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 70
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.5.10 Spanning Tree
The Spanning Tree Protocol (STP) is a network protocol to ensure loop-free topology for any
bridged Ethernet local area network.
STP Global Settings
The STP Global Settings page allows you to set the STP status, select the configuration for a BPDU
packet, choose the path overhead, force version and set the configuration revision range.
To access this page, click L2 Switching > Spanning Tree > STP Global Settings.
Figure 4-38. L2 Switching > Spanning Tree > STP Global Settings
Table 4-36. L2 Switching > Spanning Tree > STP Global Settings
Item
Description
Enabled
Click the radio-button to enable or disable the STP status.
BPDU Forward
Select flooding or filtering to designate the type of BPDU packet.
PathCost Method Select short or long to define the method of used for path cost calculations.
Force Version
Click the drop-down menu to select the operating mode for STP.
STP-Compatible: 802.1D STP operation.
RSTP-Operation: 802.1w operation.
MSTP-Operation: 802.1s operation.
Apply
Click Apply to save the values and update the screen.
The ensuing table for STP Information settings are informational only: STP, BPDU Forward,
PathCost Method and Force Version.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 71
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
STP Port Settings
The STP Port Settings page allows you to configure the ports for the setting, port’s contribution,
configure edge port, and set the status of the BPDU filter.
To access this page, click L2 Switching > Spanning Tree > STP Port Settings.
Figure 4-39. L2 Switching > Spanning Tree > STP Port Settings
Table 4-37. L2 Switching > Spanning Tree > STP Port Settings
Item
Description
Port Select
Select the port list to specify the ports that apply to this setting.
Admin Enable
Select Enabled or Disabled to setup the admin profile for the STP port.
Path Cost (0 = Auto)
Set the port’s cost contribution. For a root port, the root path cost for the bridge.
(0 means Auto).
Edge Port
Click the drop-down menu to set the edge port configuration.
No: Force to false state (as link to a bridge).
Yes: Force to true state (as link to a host).
P2P MAC
Click the drop-down menu to set the Point-to-Point port configuration.
No: Force to false state.
Yes: Force to true state.
Migrate
Click the check box to enable the migrate function.
Forces the port to use the new MST/RST BPDUs, requiring the switch to test
on the LAN segment. for the presence of legacy devices, which are not able to
understand the new BPDU formats.
Apply
Click Apply to save the values and update the screen.
The ensuing table for STP Port Status settings are informational only: Port, Admin Enable, Path
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 72
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Cost, Edge Port and P2P MAC.
STP Bridge Settings
The STP Bridge Settings page allows you to configure the priority, forward delay, maximum age,
Tx hold count, and the hello time for the bridge.
To access this page, click L2 Switching > Spanning Tree > STP Bridge Settings.
Figure 4-40. L2 Switching > Spanning Tree > STP Bridge Settings
Table 4-38. L2 Switching > Spanning Tree > STP Bridge Settings
Item
Description
Priority
Click the drop-down menu to select the STP bridge priority.
Forward Delay
Enter the variable (4 to 30) to set the forward delay for STP bridge settings.
Max Age
Enter the variable (6 to 40) to set the Max age for STP bridge settings.
Tx Hold Count
Enter the variable (1 to 10) to designate the TX hold count for STP bridge settings.
Hello Time
Enter the variable (1 to 10) to designate the Hello Time for STP bridge settings.
Apply
Click Apply to save the values and update the screen.
The ensuing table for STP Bridge Information settings are informational only: Priority, Forward
Delay, Max Age, Tx Hold Count and Hello Time.
The ensuing table for STP Bridge Status settings are informational only: Bridge Identifier,
Designated Root Bridge, Root Path Cost, Designated Bridge, Root Port and Last Topology
Change.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 73
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
STP Port Advanced Settings
The STP Port Advanced Settings page allows you to select the port list to apply this setting. To
access this page, click L2 Switching > Spanning Tree > STP Port Advanced Settings.
Figure 4-41. L2 Switching > Spanning Tree > STP Port Advanced Settings
Table 4-39. L2 Switching > Spanning Tree > STP Port Advanced Settings
Item
Description
Port Select
Select the port to designate the STP settings.
Priority
Click the drop-down menu to designate a priority.
Apply
Click Apply to save the values and update the screen.
The ensuing table for STP Port Status settings are informational only: Port, Identifier (Priority / Port
Id), Path Cost Conf/Oper, Designated Root Bridge, Root Path Cost, Designated Bridge, Edge Port
Conf/Oper, P2P MAC Conf/Oper, Port Role and Port State.
MST Config Identification
The MST Config Identification page allows you to configure the identification setting name and
the identification range.
To access this page, click L2 Switching > Spanning Tree > MST Config Identification.
Figure 4-42. L2 Switching > Spanning Tree > MST Config Identification
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 74
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-40. L2 Switching > Spanning Tree > MST Config Identification
Item
Description
Configuration Name
Enter the identifier used to identify the configuration currently being
used. It may be up to 32 characters.
Revision Level
Enter the identifier for the Revision Configuration, range: 0 to 65535
(default: 0).
Apply
Click Apply to save the values and update the screen.
The ensuing table for MST Configuration Identification Information settings are informational only:
Configuration Name and Revision Level.
MST Instance ID Settings
The MST Instance ID Settings page allows you to edit the MSTI ID and VID List settings. To access
this page, click L2 Switching > Spanning Tree > MST Instance ID Settings.
Figure 4-43. L2 Switching > Spanning Tree > MST Instance ID Settings
Table 4-41. L2 Switching > Spanning Tree > MST Instance ID Settings
Item
Description
MSTI ID
Enter the MST instance ID (0-15).
VID List
Enter the pre-configured VID list.
Move
Click Move to save the values and update the screen.
The ensuing table for MST Instance ID Information settings are informational only: MSTI ID and
VID List.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 75
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
MST Instance Priority Settings
The MST Instance Priority Settings allows you to specify the MST instance and the bridge priority
in that instance.
To access this page, click L2 Switching > Spanning Tree > MST Instance Priority Set­tings.
Figure 4-44. L2 Switching > Spanning Tree > MST Instance Priority Settings
Table 4-42. L2 Switching > Spanning Tree > MST Instance Priority Settings
Item
Description
MSTI ID
Click the drop-down menu to specify the MST instance.
Priority
Click the drop-down menu set the bridge priority in the specified MST instance
Apply
Click Apply to save the values and update the screen.
The ensuing table for MST Instance Priority Information settings are informational only: MSTI ID,
Priority and Action.
MST Instance Info
To access this page, click L2 Switching > Spanning Tree > MST Instance Info.
The ensuing table for STP Bridge Status settings are informational only: Bridge Identifier,
Designated Root Bridge, Root Path Cost, Designated Bridge, Root Port and TCNLast Topology
Change.
The ensuing table for STP Port Status settings are informational only: Port, Identifier
(Priority / Port Id), Path Cost Conf/Oper, Designated Root Bridge, Root Path Cost, Designated
Bridge, Edge Port Conf/Oper, P2P MAC Conf/Oper, Port Role and Port State.
STP Statistics
To access this page, click L2 Switching > Spanning Tree > STP Statistics.
The ensuing table for STP Statistics settings are informational only: Port, Configuration BPDUs
Received, TCN BPDUs Received, Configuration BPDUs Transmitted and TCN BPDUs Transmitted.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 76
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.5.11 X-Ring Elite
The X-Ring Elite function provides an improvement over Spanning Tree and Rapid Spanning
Tree and a rapid auto recovery in the event that the network suffers a corrupt or broken link and
prevents network loops.
X-Ring Elite Settings
The X-Ring Elite Settings allows you to enable or disable the state of the X-Ring settings.
To access this page, click L2 Switching > X-Ring Elite > X-Ring Elite Settings.
Figure 4-45. L2 Switching > X-Ring Elite > X-Ring Elite Settings
Table 4-43. L2 Switching > X-Ring Elite > X-Ring Elite Settings
Item
Description
State
Select Enabled or Disabled to setup the X-Ring Elite mode.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Information settings are informational only: X-Ring Elite State.
X-Ring Elite Groups
The X-Ring Elite Groups page allows you to select the function and role for each device and the
connected ports.
To access this page, click L2 Switching > X-Ring Elite > X-Ring Elite Groups.
Figure 4-46. L2 Switching > X-Ring Elite > X-Ring Elite Groups
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 77
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-44. L2 Switching > X-Ring Elite > X-Ring Elite Groups
Item
Description
Ring ID
Enter a number to specifies a ranging from 1 to 255 to identify a given X-Ring Elite group.
Role
Click the drop-down menu to select the ring role.
Port 1
Click the drop-down menu to define the port designation.
Port 2
Click the drop-down menu to define the port designation.
Add
Click Add to save the values and update the screen.
The ensuing table for Information settings are informational only: Ring ID, Role, Port 1, Port 2 and
Delete (click to delete the desired Ring ID).
4.5.12 X-Ring Pro
The X-Ring Pro function provides an improvement over Spanning Tree and Rapid Spanning Tree
and a rapid auto recovery in the event that the network suffers a corrupt or broken link and
prevents network loops.
X-Ring Pro Settings
The X-Ring Pro Settings page allows you to configure the status (enabled or disabled) of the
function.
To access this page, click L2 Switching > X-Ring Pro > X-Ring Pro Settings.
Figure 4-47. L2 Switching > X-Ring Pro > X-Ring Pro Settings
Table 4-45. L2 Switching > X-Ring Pro > X-Ring Pro Settings
Item
Description
State
Select Enabled or Disabled to setup the X-Ring Pro mode.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Information settings are informational only: X-Ring Pro State.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 78
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
X-Ring Pro Groups
The X-Ring Pro Groups page allows you to select the function and role for each ring ID and its
connected ports.
To access this page, click L2 Switching > X-Ring Pro > X-Ring Pro Groups.
Figure 4-48. L2 Switching > X-Ring Pro > X-Ring Pro Groups > X-Ring Pro Groups Settings
Table 4-46. L2 Switching > X-Ring Pro > X-Ring Pro Groups > X-Ring Pro Groups Settings
Item
Description
Ring ID
Enter a number to specifies a ranging from 1 to 255 to identify a given X-Ring Pro group.
Port 1
Click the drop-down menu to define the port designation.
Port 2
Click the drop-down menu to define the port designation.
Add
Click Add to save the values and update the screen.
Figure 4-49. L2 Switching > X-Ring Pro > X-Ring Pro Groups > Couple Setting
Table 4-47. L2 Switching > X-Ring Pro > X-Ring Pro Groups > Couple Setting
Item
Description
Couple Ring ID
Enter a number to specifies a ranging from 1 to 255 to identify a given XRing group.
Port
Enter the port to assign to define the couple setting.
Master Ring ID
Click the drop-down menu to designate the master ring.
Add
Click Add to save the values and update the screen.
The ensuing table for Information settings are informational only: Ring ID, Mode, Operation State,
Port 1, Forwarding State, Port 2, Forwarding State and Delete (click to delete the desired Ring ID).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 79
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.5.13 Loopback Detection
The Loopback Detection function is used to detect looped links. By sending detection frames
and then checking to see if the frames returned to any port on the device, the function is used to
detect loops.
Global Settings
The Global Settings page allows you to configure the state (enabled or disabled) of the function,
select the interval at which frames are transmitted and the delay before recovery.
To access this page, click L2 Switching > Loopback Detection > Global Settings.
Figure 4-50. L2 Switching > Loopback Detection > Global Settings
Table 4-48. L2 Switching > Loopback Detection > Global Settings
Item
Description
State
Select Enabled or Disabled to setup the loopback mode.
Interval
Enter the variable in seconds (1 to 32767) to set the interval at which frames are
transmitted.
Recover Time Enter the variable in seconds (60 to 1000000) to define the delay before recovery.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Loopback Detection Global Information settings are informational only:
State, Interval and Recover Time.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 80
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Port Settings
The Port Settings page allows you to select ports that are detected by the loopback detection
function and configure their status (enabled or disabled).
To access this page, click L2 Switching > Loopback Detection > Port Settings.
Figure 4-51. L2 Switching > Loopback Detection > Port Settings
Table 4-49. L2 Switching > Loopback Detection > Port Settings
Item
Description
Port Select
Enter the port to define the local loopback detection setting.
Enabled
Select Enabled or Disabled to setup the Loopback Detection function.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Loopback Detection Port Information settings are informational only: Port,
Enable State and Loop Status.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 81
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.6. MAC Address Table
The MAC Address Table provides access to the Static MAC Settings, MAC Aging Time, and
Dynamic Forwarding.
4.6.1 Static MAC
The Static MAC page allows you to configure the address for forwarding of packets, the VLAN ID
of the listed MAC address and the designated Port.
To access this page, click MAC Address Table > Static MAC.
Figure 4-52. MAC Address Table > Static MAC
Table 4-50. MAC Address Table > Static MAC
Item
Description
MAC Address
Enter the MAC address to which packets are statically forwarded.
VLAN
Click the drop-down menu to select the VLAN ID number of the VLAN for which the
MAC address is residing.
Port
Click the drop-down menu to select the port number.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Static MAC Status settings are informational only: No., MAC Address, VLAN,
Port and Delete (click to delete the desired MAC address).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 82
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.6.2 MAC Aging Time
The MAC Aging Time page allows you to set the MAC address of the aging time to study. To
access this page, click MAC Address Table > MAC Aging Time.
Figure 4-53. MAC Address Table > MAC Aging Time
Table 4-51. MAC Address Table > MAC Aging Time
Item
Description
Aging Time
Enter the variable (10 to 630) to define the time required for aging.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Dynamic Address Status settings are informational only: Aging time.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 83
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.6.3 Dynamic Forwarding Table
The Dynamic Forwarding function allows you to configure an address tables, which contain the
following:
»» The port each hardware address is associated with
»» The VLAN to show or clear dynamic MAC entries
»» The MAC address selection
To access this page, click MAC Address Table > Dynamic Forwarding Table.
Figure 4-54. MAC Address Table > Dynamic Forwarding Table
Table 4-52. MAC Address Table > Dynamic Forwarding Table
Item
Description
Port
Click the drop-down menu to select the port number to show or clear dynamic MAC
entries. If a port, VLAN or MAC address is not selected the whole dynamic MAC table is
displayed or cleared.
VLAN
Click the drop-down menu to select the VLAN to show or clear dynamic MAC entries.
MAC Address
Enter the MAC address to show or clear dynamic MAC entries. If a port, VLAN or MAC
address is not selected the whole dynamic MAC table is displayed or cleared.
View
Click View to display the MAC address information.
Clear
Click Clear to clear the MAC Address Information table.
The ensuing table for MAC Address Information settings are informational only: MAC Address,
VLAN, Type, Port and Add to Static MAC (click to add the MAC address to static MAC address list).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 84
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.7. Security
The Security function allows for the configuration of Storm Control, Port Security, Protected Ports,
DoS Prevention, Applications, 802.1x, and IP Security.
4.7.1 Storm Control
The Storm Control page allows you to setup the units and Preamble/IFG to manage the
occurrence of packet flooding on the LAN and consequent traffic to prevent the degrading of
network performance.
Global Settings
To access this page, click Security > Storm Control > Global Settings.
Figure 4-55. Security > Storm Control > Global Settings
Table 4-53. Security > Storm Control > Global Settings
Item
Description
Unit
Select pps or bps control units for the Storm Control function.
Preamble & IFG
Select Excluded or Included to setup the Storm Control Global settings.
Excluded: exclude preamble & IFG (20 bytes) when count ingress storm control rate.
Included: include preamble & IFG (20 bytes) when count ingress storm control rate.
Apply
Click Apply to save the values and update the screen.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 85
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Port Settings
The Port Settings page allows you to configure the port and the type of storm control association
along with the value of the storm rate for the selected port.
To access this page, click Security > Storm Control > Port Settings.
Figure 4-56. Security > Storm Control > Port Settings
Table 4-54. Security > Storm Control > Port Settings
Item
Description
Port
Enter the port number to designate the local port for the Storm Control function.
Port State
Select Disabled or Enabled to define the port state
Action
Click the drop-down menu to select the type of action to designate for the selected port
during a Storm Control incident. The options are Drop and Shutdown.
Type Enable
Click the radio button to enable Broadcast, Unknown Multicast, or Unknown Unicast
Broadcast: Select the variable in Kbps to define the broadcast bandwidth.
Unknown Multicast: Select the variable in Kbps to define the multicast setting.
Broadcast: Select the variable in Kbps to define the unknown unicast setting.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Storm Control Port Information settings are informational only: Port, Port
State, Broadcast (Kbps), Unknown Multicast (Kbps), Unknown Unicast (Kbps) and Action.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 86
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.7.2 Port Security
The Port Security page allows you to configure port isolation behavior. To access this page, click
Security > Port Security.
Figure 4-57. Security > Port Security
Table 4-55. Security > Port Security
Item
Description
Port Select
Enter a single or multiple port numbers to configure.
Enabled
Select Enabled or Disabled to define the selected Port.
FDB Learn Limit (0-64) Enter the variable (0 to 64) to set the learn limit for the FDB setting.
Violation MAC
Notification
Select Enabled or Disabled to define the selected Port.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Port Security Information settings are informational only: Port, Enabled, FDB
Learn Limit and Violation MAC Notification.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 87
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.7.3 Protected Ports
The Protected Port page allows you to configure a single or multiple ports as a protected or
unprotected type.
To access this page, click Security > Protected Ports.
Figure 4-58. Security > Protected Ports
Table 4-56. Security > Protected Ports
Item
Description
Port List
Enter the port number to designate for the Protected Port setting.
Port Type
Select Unprotected or Protected to define the port type.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Protected Ports Status settings are informational only: Protected Ports and
Unprotected Ports.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 88
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.7.4 DoS Prevention
DoS Global Settings
The DoS Global Settings page allows you to enabled or disable the setting for each function.
To access this page, click Security > DoS Prevention > DoS Global Settings.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 89
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Figure 4-59. Security > DoS Prevention > DoS Global Settings
Table 4-57. Security > DoS Prevention > DoS Global Settings
Item
Description
DMAC = SMAC
Click Enabled or Disabled to define DMAC-SMAC for the DoS Global settings.
LAND
Click Enabled or Disabled to define LAND for the DoS Global settings.
UDP Blat
Click Enabled or Disabled to define UDP Blat for the DoS Global settings.
TCP Blat
Click Enabled or Disabled to define TCP Blat for the DoS Global settings.
POD
Click Enabled or Disabled to define POD for the DoS Global settings.
IPv6 Min Fragment
Click Enabled or Disabled to define minimum fragment size for the IPv6
protocol.
Enter the variable in bytes (0 to 65535) to set the minimum fragment size when
the function is enabled.
ICMP Fragments
Click Enabled or Disabled to define the ICMP Fragments function.
IPv4 Ping Max Size
Click Enabled or Disabled to set the maximum ping size for the IPv4 protocol.
IPv6 Ping Max Size
Click Enabled or Disabled to set a maximum ping size for the IPv6 protocol.
Ping Max Size Setting
Enter the variable in bytes (0 to 65535) to set the maximum ping size.
Smurf Attack
Click Enabled or Disabled to set the Smurf Attack function.
TCP Min Hdr Size
Click Enabled or Disabled to set the minimum header size.
Enter the variable in bytes (0 to 31) to set the minimum header size.
TCP-SYN (SPORT < 1024) Click Enabled or Disabled to set the TCP synchronization function (sport < 1021).
Null Scan Attack
Click Enabled or Disabled to set the Null Scan Attack function.
X-Mas Scan Attack
Click Enabled or Disabled to set the X-Mas Scan function.
TCP SYN-FIN Attack
Click Enabled or Disabled to set the TCP synchronization termination attack
function.
TCP SYN-RST Attack
Click Enabled or Disabled to set the TCP synchronization reset attack function.
TCP Fragment (Offset = 1)Click Enabled or Disabled to set the TCP fragment function (offset =1).
Apply
Click Apply to save the values and update the screen.
The ensuing table for DoS Global Information settings are informational only: DMAC = SMAC,
Land Attack, UDP Blat, TCP Blat, POD (Ping of Death), IPv6 Min Fragment Size, ICMP Fragment
Packets, IPv4 Ping Max Packet Size, IPv6 Ping Max Packet Size, Smurf Attack, TCP Min Header
Length, TCP Syn (SPORT < 1024), Null Scan Attack, X-Mas Scan Attack, TCP SYN-FIN Attack, TCP
SYN-RST Attack and TCP Fragment (Offset = 1).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 90
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
DoS Port Settings
The DoS Port Settings page allow you to configure DoS security (enabled or disabled) for the
selected port.
To access this page, click Security > DoS Prevention > DoS Port Settings.
Figure 4-60. Security > DoS Prevention > DoS Port Settings
Table 4-58. Security > DoS Prevention > DoS Port Settings
Item
Description
Port
Select the port to configure for the DoS prevention function.
DoS Protection
Click Enabled or Disabled to set the DoS Port security function state.
Apply
Click Apply to save the values and update the screen.
The ensuing table for DoS Port Status settings are informational only: Port and DoS Protection.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 91
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.7.5 Applications
The Applications function allows you to configure various types of AAA lists.
TELNET
The TELNET page allows you to combine all kinds of AAA lists with the Telnet line. To access this
page, click Security > Applications > TELNET.
Figure 4-61. Security > Applications > TELNET
Table 4-59. Security > Applications > TELNET
Item
Description
Telnet Service
Click Enabled or Disabled to set remote access through the Telnet Service function.
Apply
Click Apply to save the values and update the screen.
Disconnect
Click Disconnect to disable the current Telnet service.
The ensuing table for Telnet Information settings are informational only: Telnet Service and
Current Telnet Sessions Count.
SSH
Secure Shell (SSH) is a protocol providing secure (encrypted) management connection to a remote
device.
To access this page, click Security > Applications > SSH.
Figure 4-62. Security > Applications > SSH
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 92
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-60. Security > Applications > SSH
Item
Description
SSH Service
Click Enabled or Disabled to set up Ethernet encapsulation (remote access) through the
Secure Shell (SSH) function.
Apply
Click Apply to save the values and update the screen.
The ensuing table for SSH Information settings are informational only: SSH.
HTTP
The HTTP page allows you to combine all kinds of AAA lists to the HTTP line. Attempts to access
the switch’s Web UI from HTTP are first authenticated.
To access this page, click Security > Applications > HTTP.
Figure 4-63. Security > Applications > HTTP
Table 4-61. Security > Applications > HTTP
Item
Description
HTTP Service
Click Enabled or Disabled to set up Ethernet encapsulation (remote access) through
HTTP function.
Session Timeout
Enter the variable in minutes (0 to 86400) to define the timeout period for the HTTP
session.
Apply
Click Apply to save the values and update the screen.
The ensuing table for HTTP Information settings are informational only: HTTP Service and Session
Timeout.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 93
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
HTTPS
The HTTPS page allows you to combine all kinds of AAA lists on the HTTPS line. Attempts to
access the switch’s Web UI from HTTPS are first authenticated.
To access this page, click Security > Applications > HTTPS.
Figure 4-64. Security > Applications > HTTPS
Table 4-62. Security > Applications > HTTPS
Item
Description
HTTPS Service
Click Enabled or Disabled to set up Ethernet encapsulation over HTTPS.
Session Timeout
Enter the variable in minutes (0 to 86400) to define the timeout period for the HTTP
session.
Apply
Click Apply to save the values and update the screen.
The ensuing table for HTTPS Information settings are informational only: HTTPS Service and
Session Timeout.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 94
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.7.6 802.1x
The 802.1x function provides port-based authentication to prevent unauthorized devices (clients)
from gaining access to the network.
802.1x Settings
The 802.1x Settings page allows you to set the state (enabled or disabled) for the selected IP
server address, port, accounting port and associated password, including a reauthentication
period.
To access this page, click Security > 802.1x > 802.1x Settings.
Figure 4-65. Security > 802.1x > 802.1x Settings
Table 4-63. Security > 802.1x > 802.1x Settings
Item
Description
State
Click Enabled or Disabled to set up 802.1x Setting function.
Server IP
Enter the IP address of the local server providing authentication function.
Server Port
Enter the port number (1 to 65535) assigned to the listed Server IP.
Accounting Port
Enter the port number (1 to 65535) assigned to the listed server IP configured to
provide authorization and authentication for network access.
Security Key
Enter the variable to define the network security key used in authentication.
Reauth Period
Enter the variable in seconds to define the period of time between authentication
attempts.
Apply
Click Apply to save the values and update the screen.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 95
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
802.1x Port Configuration
The 802.1x Port Configuration page allows you to identify the authorization state for a port by
using a MAC or Port authentication base.
To access this page, click Security > 802.1x > 802.1x Port Configuration.
Figure 4-66. Security > 802.1x > 802.1x Port Configuration
Table 4-64. Security > 802.1x > 802.1x Port Configuration
Item
Description
Authentication
based
Click Port or Mac to designate the type of configuration for the 802.1x Port setting.
Port Select
Enter the port number associated with the configuration setting.
State
Click Authorize or Disabled to define the listed port’s state mode.
Apply
Click Apply to save the values and update the screen.
The ensuing table for 802.1x Port Authorization settings are informational only: Port and Port State.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 96
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.7.7 IP Security
This section provides you a means to configure the IP Security settings.
Global Settings
The Global Settings page allows you to set the IP Security status (enabled or disabled). To access
this page, click Security > IP Security > Global Settings.
Figure 4-67. Security > IP Security > Global Settings
Table 4-65. Security > IP Security > Global Settings
Item
Description
Status
Click Enabled or Disabled to define the global setting for the IP security function.
Apply
Click Apply to save the values and update the screen.
The ensuing table for IP Security Status settings are informational only: IP Security.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 97
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Entry Settings
Once the Global Setting is enabled, use the Entry Settings to define an IP Security entry. To access
this page, click Security > IP Security > Entry Settings.
Figure 4-68. Security > IP Security > Entry Settings
Table 4-66. Security > IP Security > Entry Settings
Item
Description
IP Address
Enter the source IP address to apply the IP Security function.
IP Mask
Enter the IP address for use in masking the previous IP Address.
Services
Enter the type of services to associate with the entry setting.
Apply
Click Apply to save the values and update the screen.
The ensuing table for IP Security Entry Information settings are informational only: IP Address, IP
Mask, Services and Action.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 98
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.8. QoS
The QoS function allows you to configure settings for the switch QoS interface and how the switch
connects to a remote server to get services.
4.8.1 General
Traditionally, networks operate on a best-effort delivery basis, all traffic has equal priority and an
equal chance of being delivered in a timely manner. When there is congestion, all traffic has an
equal chance of being dropped.
The QoS feature can be configured for congestion-management and congestion-avoidance to
specifically manage the priority of the traffic delivery. Implementing QoS in the network makes
performance predictable and bandwidth utilization much more effective.
The QoS implementation is based on the prioritization values in Layer 2 frames.
QoS Properties
The QoS Properties allows you to set the QoS mode.
To access this page, click QoS > General > QoS Properties.
Figure 4-69. QoS > General > QoS Properties
Table 4-67. QoS > General > QoS Properties
Item
Description
QoS Mode
Select Disabled or Basic to setup the QoS function.
Apply
Click Apply to save the values and update the screen.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 99
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
QoS Settings
Once the QoS function is enabled, you can configure the available settings. To access this page,
click QoS > General > QoS Settings.
Figure 4-70. QoS > General > QoS Settings
Table 4-68. QoS > General > QoS Settings
Item
Description
Port
Enter the port number to associate with the QoS setting.
CoS Value
Click the drop-down menu to designate the Class of Service (CoS) value (0 to 7) for
the Port entry.
Remark CoS
Click Disabled or Enabled to setup the Remark CoS function. When enabled the LAN
(preassigned priority values) is marked at Layer 2 boundary to CoS values.
Remark DSCP
Click Disabled or Enabled to setup the DSCP remark option for the QoS function.
Remark IP
Precedence
Click Disabled or Enabled to setup the Remark IP Precedence for the QoS function.
Apply
Click Apply to save the values and update the screen.
The ensuing table for QoS Status settings are informational only: Port, CoS value, Remark CoS,
Remark DSCP and Remark IP Precedence.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 100
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Queue Scheduling
The switch support eight CoS queues for each egress port. For each of the eight queues, two
types of scheduling can be configured: Strict Priority and Weighted Round Robin (WRR).
Strict Priority scheduling is based on the priority of queues. Packets in a high-priority queue are
always sent first and packets in a low-priority queue are only sent after all the high priority queues
are empty.
Weighted RoundRobin (WRR) scheduling is based on the user priority specification to indicate the
importance (weight) of the queue relative to the other CoS queues. WRR scheduling prevents lowpriority queues from being completely ignored during periods of high priority traffic. The WRR
scheduler sends some packets from each queue in turn.
To access this page, click QoS > General > QoS Scheduling.
Figure 4-71. QoS > General > QoS Scheduling
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 101
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-69. QoS > General > QoS Scheduling
Item
Description
Queue
Queue entry for egress port.
Strict
Select Strict to assign the scheduling designation to the selected queue.
WRR
Select WRR to assign the scheduling designation to the selected queue.
Weight
Enter a queue priority (weight) relative to the defined entries (WRR only).
% of WRR
Bandwidth
Displays the allotted bandwidth for the queue entry in percentage values.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Queue Information settings are informational only: Strict Priority Queue
Number.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 102
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
CoS Mapping
The CoS Mapping allows you to apply CoS mapping.
To access this page, click QoS > General > CoS Mapping.
Figure 4-72. QoS > General > CoS Mapping
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 103
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-70. QoS > General > CoS Mapping
Item
Description
CoS to Queue Mapping
Class of Service
Displays the CoS for the queue entry.
Queue
Click the drop-down menu to select the queue priority for selected CoS
Queue to CoS Mapping
Queue
Displays the queue entry for CoS mapping.
Class of Service
Click the drop-down menu to select the CoS type
Apply
Click Apply to save the values and update the screen.
The ensuing table for CoS Mapping Information settings are informational only: CoS and Mapping
to Queue.
The ensuing table for Queue Mapping Information settings are informational only: Queue and
Mapping to CoS.
DSCP Mapping
The DSCP to Queue mapping function maps queue values in incoming packets to a DSCP value
that QoS uses internally to represent the priority of the traffic. The following table shows the DSCP
to Queue map.
If these values are not appropriate for your network, you need to modify them. To access this
page, click QoS > General > DSCP Mapping.
Figure 4-73. QoS > General > DSCP Mapping.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 104
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-71. QoS > General > DSCP Mapping
Item
Description
DSCP to Queue Mapping
DSCP
Enter the DSCP entry to define the precedence values.
Queue
Click the drop-down menu to select the queue designation for the DSCP value.
Queue to DSCP Mapping
Queue
Displays the queue value for the DSCP map.
DSCP
Enter the DSCP entry to define the precedence values.
Apply
Click Apply to save the values and update the screen.
The ensuing table for DSCP Mapping Information settings are informational only: DSCP and
Mapping to Queue.
The ensuing table for Queue Mapping Information settings are informational only: Queue and
Mapping to DSCP.
IP Precedence Mapping
The IP Precedence Mapping allows you to set IP Precedence mapping. To access this page, click
QoS > General > IP Precedence Mapping.
Figure 4-74. QoS > General > IP Precedence Mapping
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 105
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-72. QoS > General > IP Precedence Mapping
Item
Description
IP Precedence to Queue Mapping
IP Precedence
Displays the IP precedence value for the queue map.
Queue
Click the drop-down menu to map a queue value to the selected IP precedence.
Queue to IP Precedence Mapping
Queue
Displays the queue entry for mapping IP precedence values.
IP Precedence
Click the drop-down menu to map an IP precedence value to the selected queue.
Apply
Click Apply to save the values and update the screen.
The ensuing table for IP Precedence Mapping Information settings are informational only: IP
Precedence and Mapping to Queue.
The ensuing table for Queue Mapping Information settings are informational only: Queue and
Mapping to IP Precedence.
4.8.2 QoS Basic Mode
Quality of Service (QoS) allows to give preferential treatment to certain types of traffic at the
expense of others. Without QoS, the switch offers best-effort service to each packet, regardless of
the packet contents or size sending the packets without any assurance of reliability, delay bounds,
or throughput.
QoS mode supports two modes: 802.1p and DSCP.
Global Settings
The Global Settings page allows you to configure the trust mode to a port selection. To access this
page, click QoS > QoS Basic Mode > Global Settings.
The function is only available when QoS Properties is set to Basic.
Figure 4-75. QoS > QoS Basic Mode > Global Settings
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 106
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-73. QoS > QoS Basic Mode > Global Settings
Item
Description
Trust Mode
Click the drop-down menu to select the trust state of the QoS basic mode.
Apply
Click Apply to save the values and update the screen.
The ensuing table for QoS Information settings are informational only: Trust Mode.
Port Settings
The Port Settings page allows you to define a trust state (enabled or disabled) to a listed port.
To access this page, click QoS > QoS Basic Mode > Port Settings.
Figure 4-76. QoS > QoS Basic Mode > Port Settings
Table 4-74. QoS > QoS Basic Mode > Port Settings
Item
Description
Port
Enter the port number for the QoS basic mode setting.
Trust State
Select Enabled or Disabled to set the port’s trust state status.
Apply
Click Apply to save the values and update the screen.
The ensuing table for QoS Port Status settings are informational only: Port and Trust State.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 107
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.8.3 Rate Limit
Rate Limits features control on a per port basis. Bandwidth control is supported for the following:
Ingress Bandwidth Control, Egress Bandwidth Control and Egress Queue.
Ingress Bandwidth Control
The Ingress Bandwidth Control page allows you to configure the bandwidth control for a listed
port.
To access this page, click QoS > Rate Limit > Ingress Bandwidth Control.
Figure 4-77. QoS > Rate Limit > Ingress Bandwidth Control
Table 4-75. QoS > Rate Limit > Ingress Bandwidth Control
Item
Description
Port
Enter the port number for the rate limit setup.
State
Select Disabled or Enabled to set the port’s state status.
Rate (Kbps)
Enter the value in Kbps (16 to 1000000) to set as the bandwidth rate for the selected port.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Ingress Bandwidth Control Status settings are informational only: Port and
Ingress Rate Limit (Kbps).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 108
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Egress Bandwidth Control
The Egress Bandwidth Control page allows you to set the egress bandwidth control for a listed
port.
To access this page, click QoS > Rate Limit > Egress Bandwidth Control.
Figure 4-78. QoS > Rate Limit > Egress Bandwidth Control
Table 4-76. QoS > Rate Limit > Egress Bandwidth Control
Item
Description
Port
Enter the port number to set the Egress Bandwidth Control.
State
Select Disabled or Enabled to set the Egress Bandwidth Control state.
Rate (Kbps)
Enter the value in Kbps (16 to 1000000) to set the Egress Bandwidth rate.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Egress Bandwidth Control Status settings are informational only: Port and
Egress Rate Limit (Kbps).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 109
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Egress Queue
The Egress Queue page allows you to set the egress bandwidth parameters. To access this page,
click QoS > Rate Limit > Egress Queue.
Figure 4-79. QoS > Rate Limit > Egress Queue
Table 4-77. QoS > Rate Limit > Egress Queue
Item
Description
Port
Click the drop-down menu to select the port to define the Egress queue.
Queue
Click the drop-down menu to set the queue order for the Egress setting.
State
Click Disabled or Enabled to set the Egress queue state.
CIR (Kbps)
Enter the value in Kbps (16 to 1000000) to set the CIR rate for the Egress queue.
Apply
Click Apply to save the values and update the screen.
The ensuing table for FE1 Egress Per Queue Status settings are informational only: Queue Id and
Egress Rate Limit (Kbps).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 110
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.9. Management
4.9.1 LLDP
LLDP is a one-way protocol without request/response sequences. Information is advertised
by stations implementing the transmit function, and is received and processed by stations
implementing the receive function.
LLDP System Settings
The LLDP System Settings allows you to configure the status (enabled or disabled) for
the protocol, set the interval for frame transmission, set the hold time multiplier and the
re-initialization delay.
To access this page, click Management > LLDP > LLDP System Settings.
Figure 4-80. Management > LLDP > LLDP System Settings
Table 4-78. Management > LLDP > LLDP System Settings
Item
Description
Enabled
Click Enabled or Disabled to set the Global Settings state.
LLDP PDU Disable
Action
Click to select the LLDP PDU handling action when LLDP is globally disabled.
Options include: Filtered, Bridged, or Flooded.
Transmission Interval
Select the interval at which frames are transmitted. The default is 30 seconds, and
the valid range is 5 to 32768 seconds.
Holdtime Multiplier
Select the multiplier on the transmit interval to assign to TTL.
Reinitialization Delay
Select the delay length before re-initialization.
Transmit Delay
Select the delay after an LLDP frame is sent.
Apply
Click Apply to save the values and update the screen.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 111
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
The ensuing table for LLDP Global Config settings are informational only: LLDP Enabled, LLDP
PDU Disable Action, Transmission Interval, Holdtime Multiplier, Reinitialization Delay and Transmit
Delay.
LLDP Port Settings
The LLDP Port Settings page allows you to configure the state (enabled or disabled) of the
selected port.
To access this page, click Management > LLDP > LLDP Port Settings.
Figure 4-81. Management > LLDP > LLDP Port Settings > LLDP Port Configuration
Table 4-79. Management > LLDP > LLDP Port Settings > LLDP Port Configuration
Item
Description
Port Select
Enter the port number associated with the LLDP setting.
State
Click the drop-down menu to select the LLDP port state.
Apply
Click Apply to save the values and update the screen.
Figure 4-82. Management > LLDP > LLDP Port Settings > Optional TLVs Selection
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 112
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-80. Management > LLDP > LLDP Port Settings > Optional TLVs Selection
Item
Description
Port Select
Enter the port number associated with the TLV (optional) selection.
Optional TLV
Select
Click the drop-down menu to select the LLDP optional TLVs to be carried (multiple
selections are allowed).
· System Name: To include system name TLV in LLDP frames.
· Port Description: To include port description TLV in LLDP frames.
· System Description: To include system description TLV in LLDP frames.
· System Capability: To include system capability TLV in LLDP frames.
· 802.3 MAC-PHY:
· 802.3 Link Aggregation:
· 802.3 Maximum Frame Size:
· Management Address:
· 802.1 PVID:
Apply
Click Apply to save the values and update the screen.
The ensuing table for LLDP Port Status settings are informational only: Port, State and Selected
Optional TLVs.
Figure 4-83. Management > LLDP > LLDP Port Settings > VLAN Name TLV VLAN Selection
Table 4-81. Management > LLDP > LLDP Port Settings > VLAN Name TLV VLAN Selection
Item
Description
Port Select
Enter the port number to associated with the TLV selection.
VLAN Select
Select the VLAN Name ID to be carried out (multiple selection is allowed).
Apply
Click Apply to save the values and update the screen.
The ensuing table for LLDP Port VLAN TLV Status settings are informational only: Port and
Selected VLAN.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 113
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
LLDP Local Device Info
The LLDP Local Device Info page allows you to view information regarding network devices,
providing that the switch has already obtained LLDP information on the devices.
To access this page, click Management > LLDP > LLDP Local Device Info.
The ensuing table for Local Device Summary settings are informational only: Chassis ID Subtype,
Chassis ID, System Name, System Description, Capabilities Supported, Capabilities Enabled and
Port ID Subtype.
The ensuing table for Port Status settings are informational only: Port, Selected VLAN and Detail
(click the radio box and click Detail to displays the details).
LLDP Remote Device Info
The LLDP Remote Device Info page allows you to view information about remote devices, LLDP
information must be available on the switch.
To access this page, click Management > LLDP > LLDP Remote Device Info
Figure 4-84. Management > LLDP > LLDP Remote Device Info
Table 4-82. Management > LLDP > LLDP Remote Device Info
Item
Description
Detail
Click to display the device details.
Delete
Click to delete the selected devices.
Refresh
Click to refresh the remote device information list.
LLDP Overloading
To access this page, click Management > LLDP > LLDP Overloading.
The ensuing table for LLDP Overloading settings are informational only: Port, Total (Bytes), Left to
Send (Bytes), Status and Status (Mandatory TLVs, 802.3 TLVs, Optional TLVs and 802.1 TLVs).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 114
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.9.2 SNMP
Simple Network Management Protocol (SNMP) is a protocol to facilitate the monitoring and
exchange of management information between network devices. Through SNMP, the health of the
network or status of a particular device can be determined.
SNMP Settings
The SNMP Settings page allows you to set the SNMP daemon state (enabled or disabled). To
access this page, click Management > SNMP > SNMP Settings.
Figure 4-85. Management > SNMP > SNMP Settings
Table 4-83. Management > SNMP > SNMP Settings
Item
Description
State
Click Enabled or Disabled to define the SNMP daemon.
Apply
Click Apply to save the values and update the screen.
The ensuing table for SNMP Information settings are informational only: SNMP.
SNMP Community
The SNMP Community page provides configuration options for the community.
SNMP v1 and SNMP v2c use the group name (Community Name) certification. It’s role is similar
to the password function. If SNMP v1 and SNMP v2c are used, you can go directly from the
configuration settings to this page to configure the SNMP community.
To access this page, click Management > SNMP > SNMP Community.
Figure 4-86. Management > SNMP > SNMP Community
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 115
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-84. Management > SNMP > SNMP Community
Item
Description
Community Name
Enter a community name (up to 20 characters).
Access Right
Click the radio box to specify the access level (read only or read write)
Apply
Click Apply to save the values and update the screen.
The ensuing table for Community Status settings are informational only: No., Community Name,
Access Right and Delete (click to delete the desired community name).
SNMP User Settings
The SNMP User Settings page allows you to create SNMP groups. The users have the same level
of security and access control permissions as defined by the group settings.
To access this page, click Management > SNMP > SNMP User Settings.
Figure 4-87. Management > SNMP > SNMP User Settings
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 116
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-85. Management > SNMP > SNMP User Settings
Item
Description
User Name Enter a user name (up to 32 characters) to create an SNMP profile.
Access
Right
Click read-only or read-write to define the access right for the profile.
Encrypted
Click the option to set the encrypted option for the user setting.
AuthProtocol
Click the drop-down menu to select the authentication level: MD5 or SHA.
The field requires a user password.
MD5: specify HMAC-MD5-96 authentication level
SHA: specify HMAC-SHA authentication protocol
Password
Enter the characters to define the password associated with the
authentication protocol.
PrivProtocol
Click the drop-down menu to select an authorization protocol: none or
DES.The field requires a user password.
None: no authorization protocol in use
DES: specify 56-bit encryption in use
Password
Enter the characters to define the password associated with the authorization protocol.
Add
Click Add to save the values and update the screen.
The ensuing table for User Status settings are informational only: User Name, Access Right, AuthProtocol, Priv-Protocol and Delete (click to delete the desired user name).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 117
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
SNMP Trap
The SNMP Trap page allows you to set the IP address of the node and the SNMP credentials
corresponding to the version that is included in the trap message.
To access this page, click Management > SNMP > SNMP Trap.
Figure 4-88. Management > SNMP > SNMP Trap
Table 4-86. Management > SNMP > SNMP Trap
Item
Description
IP Address
Enter the IP address to designate the SNMP trap host.
Community Name Click the drop-down menu to select a defined community name.
Version
Click the drop-down menu to designate the SNMP version credentials (v1 or v2c).
Add
Click Add to save the values and update the screen.
The ensuing table for Trap Host Status settings are informational only: No., IP Address, Community
Name, Version and Delete (click to delete the desired IP address).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 118
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.9.3 Power Over Ethernet
Power Over Ethernet is the function supplying power to Powered Devices (PD) through the switch
in the event that AC power is not readily available.
Power over Ethernet can be used for the following areas:
»» Surveillance devices
»» I/O sensors for security requirements
»» Wireless access points
PoE System Settings
The PoE System Settings page allows you to configure the overload disconnect and the maximum
available wattage.
To access this page, click Management > Power Over Ethernet > PoE System Settings.
Figure 4-89. Management > Power Over Ethernet > PoE System Settings
Table 4-87. Management > Power Over Ethernet > PoE System Settings
Item
Description
Maximum
Power Available
Select the value in Watts to set the maximum available power.
OverLoad
Disconnect Mode
Click the drop-down menu to designate the overload mode:
Overload Port First:
Port-Based Priority:
Apply
Click Apply to save the values and update the screen.
The ensuing table for PoE System Information settings are informational only: Firmware Version,
Maximum Power Available, Actual Power Consumption and Overload Disconnect Type.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 119
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
PoE Port Settings
The PoE Port Settings page allows you to configure the port status, its power limitations, legacy
mode status, and power limit settings.
To access this page, click Management > Power Over Ethernet > PoE Port Settings.
Figure 4-90. Management > Power Over Ethernet > PoE Port Settings
Table 4-88. Management > Power Over Ethernet > PoE Port Settings
Item
Description
Port
Click the drop-down menu to select a PoE port.
Enabled
Select Enabled or Disabled to designate the PoE port function by ports.
Power Limit From
Classification
Select Enabled or Disabled to designate the power limit classification.
Legacy Mode
Select Enabled or Disabled to designate the legacy mode option for the port.
Priority
Click the drop-down menu to configure the power supply priority: Critical, Low,
Medium or High. Default is Low.
Power Limit
Enter a number to set the port power current limitation to be given to the Powered
Device (PD)
Apply
Click Apply to save the values and update the screen.
The ensuing table for PoE Information settings are informational only: Port, Enable State, Power
Limit From Classification, Priority, Legacy and Power Limit (W).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 120
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
PoE Port Status
To access this page, click Management > Power Over Ethernet > PoE Port Status.
The ensuing table for PoE Port Status settings are informational only: Port, Current (mA), Voltage
(V), Power (W) and Temp. (°C).
4.9.4 TCP Modbus
The TCP Modbus function allows for client-server communication between a switch module
(server) and a device in the networking running MODBUS client software (client).
TCP Modbus Settings
The TCP Modbus Settings page allows you to configure the modbus function.
To access this page, click Management > TCP Modbus > TCP Modbus Settings.
Figure 4-91. Management > TCP Modbus > TCP Modbus Settings
Table 4-89. Management > TCP Modbus > TCP Modbus Settings
Item
Description
State
Click Disabled or Enabled to set the TCP Modbus state.
Time out
Enter the value (1 to 86400) to define the timeout period between transport time.
Apply
Click Apply to save the values and update the screen.
The ensuing table for TCP Modbus Status settings are informational only: TCP Modbus status and
TCP Modbus time out.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 121
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.9.5 DHCP Server
The Dynamic Host Configuration Protocol (DHCP) is a network protocol enabling a server to
automatically assign an IP address to a computer from a defined range of numbers configured for
a given network.
Status Settings
The Status Settings page allows you to configure the DHCP server mode (enabled or disabled).
To access this page, click Management > DHCP Server > Status Settings.
Figure 4-92. Management > DHCP Server > Status Settings
Table 4-90. Management > DHCP Server > Status Settings
Item
Description
DHCP Server
Select Enable or Disable to designate the DHCP server function type
When a new DHCP server mode is selected, the switch requires a system restart for the
new mode to take effect.
Apply
Click Apply to save the values and update the screen.
Restart
Click Restart to have the switch perform a system restart function. In the event that the
IP settings are changed, the DHCP server must be restarted for the IP settings to take
effect.
The ensuing table for Status Information settings are informational only: DHCP Server Service.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 122
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Global Settings
The Global Settings page allows you to configure the global settings for the DHCP function. To
access this page, click Management > DHCP Server > Global Settings.
Figure 4-93. Management > DHCP Server > Global Settings
Table 4-91. Management > DHCP Server > Global Settings
Item
Description
Lease Time
Type in the value designating the lease time (60 - 864000) in seconds for each setting lease.
Low IP
Address
Type in the value designating the lowest range in the IP address pool.
High IP
Address
Type in the value designating the highest range in the IP address pool.
Subnet Mask Type in the value designating the subnet mask for the IP address pool.
Gateway
Type in the value designating the gateway for the IP address pool.
DNS
Type in the value designating the DNS for the IP address pool.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Global Information settings are informational only: Lease Time, Low IP
Address, High IP Address, Subnet Mask, Gateway, DNS and Clear (click to clear IP pool).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 123
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Port Settings
The Port Settings page allows you to configure selected ports for the DHCP function. To access
this page, click Management > DHCP Server > Port Settings.
Figure 4-94. Management > DHCP Server > Port Settings
Table 4-92. Management > DHCP Server > Port Settings
Item
Description
Port Select
Click the drop-down menu to select a pre-defined port to configure. The suboptions
are designated for the selected port.
Low IP Address
Type in the value designating the lowest range in the IP address pool.
High IP Address
Type in the value designating the highest range in the IP address pool.
Subnet Mask
Type in the value designating the subnet mask for the IP address pool.
Gateway
Type in the value designating the gateway for the IP address pool.
DNS
Type in the value designating the DNS for the IP address pool.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Port Information settings are informational only: Port, Low IP Address, High
IP Address, Subnet Mask, Gateway, DNS, Edit (click to modify the settings) and Clear (click to clear
the settings).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 124
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Option 82 Settings
The Option 82 Settings, also known as the DHCP relay agent information option, provide
information about the network location of a DHCP client. In turn, the DHCP server uses the
information to implement IP addresses or other parameters for the client.
To access this page, click Management > DHCP Server > Option 82 Settings.
Figure 4-95. Management > DHCP Server > Option 82 Settings
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 125
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-93. Management > DHCP Server > Option 82 Settings
Item
Description
Entry
Click the drop-down menu to select an entry for the Option 82 setting.
Circuit ID Format
Click the drop-down menu to select the format of the circuit ID: string or hex.
Circuit ID Content Enter the circuit ID string on the switch on which the request was received.
Remote ID Format Click the drop-down menu to select the format of the remote ID: string or hex.
Remote ID Content Enter the remote ID string of the host.
Low IP Address
Type in the value designating the lowest range in the IP address pool.
High IP Address
Type in the value designating the highest range in the IP address pool.
Subnet Mask
Type in the value designating the subnet mask for the IP address pool.
Gateway
Type in the value designating the gateway for the IP address pool.
DNS
Type in the value designating the DNS for the IP address pool.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Entry Information settings are informational only: Entry (click the dropdown menu to select an entry), Entry ID, Circuit ID Format, Circuit ID Content, Remote ID Format,
Remote ID Content, Low IP Address, High IP Address, Subnet Mask, Gateway, DNS, Edit (click to
modify the settings) and Clear (click to clear the settings).
Lease Entry
To access this page, click Management > DHCP Server > Lease Entry.
The ensuing table for Lease entry Table settings are informational only: IP Address, Client Mac,
Start Time, End Time and Type.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 126
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.9.6 SMTP Client
Simple Mail Transfer Protocol (SMTP) is a protocol to send e-mail messages between servers.
SMTP is used to send messages from a mail client to a mail server. SMTP by default uses TCP port
25.
Global Settings
The Global Settings page allows you to set the active profile for the SMTP client. To access this
page, click Management > SMTP Client > Global Settings.
Figure 4-96. Management > SMTP Client > Global Settings
Table 4-94. Management > SMTP Client > Global Settings
Item
Description
Active Profile
Click the drop-down menu to select the profile status (None, 1 or 2).
Apply
Click Apply to save the values and update the screen.
The ensuing table for SMTP Information settings are informational only: Active Profile Id.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 127
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Profile Settings
The Profile Settings page allows you to select the server IP, the server port, and sender mail for
the listed profile.
To access this page, click Management > SMTP Client > Profile Settings.
Figure 4-97. Management > SMTP Client > Profile Settings > Profile Settings
Table 4-95. Management > SMTP Client > Profile Settings > Profile Settings
Item
Description
Profile ID
Click the drop-down menu to select the identification type for the profile (1 or 2).
Server IP
Enter the IP address to designate the server host.
Server Port
Enter the port number to designate the port associated with the server IP address.
Sender Mail
Enter the email address of the sender client.
Apply
Click Apply to save the values and update the screen.
Figure 4-98. Management > SMTP Client > Profile Settings > Profile Target Mail Settings
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 128
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-96. Management > SMTP Client > Profile Settings > Profile Target Mail Settings
Item
Description
Profile ID
Click the drop-down menu to select the identification type for the profile (1 or 2).
Target Mail
Enter the email address of the target client.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Profile Information settings are informational only: Profile ID (click the dropdown menu to select a profile ID), Server IP, Server Port and Sender Mail Address.
Sending Message
The Sending Message page allows you to setup the log message for use with the SMTP client.
To access this page, click Management > SMTP Client > Sending Message.
Figure 4-99. Management > SMTP Client > Sending Message
Table 4-97. Management > SMTP Client > Sending Message
Item
Description
Title
Assign the title of the email. The maximum length is 20 characters (alphanumeric, symbols (.
(dot), _ (underline), - (dash line) and space).
Content
Assign the content of the email. The maximum length is 64 characters (alphanumeric,
symbols (. (dot), _ (underline), - (dash line) and space).
Apply
Click Apply to save the values and update the screen.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 129
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.9.7 RMON
Remote monitoring (RMON) uses a client-server model to monitor/manage remote devices on a
network.
RMON Statistics
The RMON Statistics page allows you to view information regarding packet sizes and information
for physical layer errors. The information displayed is according to the RMON standard.
To access this page, click Management > RMON > RMON Statistics.
Figure 4-100. Management > RMON > Rmon Statistics
Table 4-98. Management > RMON > Rmon Statistics
Item
Description
Index
Enter an entry selection (1 to 65535) to display its statistical information.
Port
Enter the respective port number for the selected entry.
Owner
Enter the name of the owner of the RMON group.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Statistics Information settings are informational only: Index, Port, Drop
Events, Octets, Packets, Broadcast, Multicast, Owner and Delete (click to delete the desired index).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 130
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
RMON History
The RMON History page allows you to configure the display of history entries. To access this page,
click Management > RMON > RMON History.
Figure 4-101. Management > RMON > RMON History
Table 4-99. Management > RMON > RMON History
Item
Description
Index
Enter the index entry (1 to 65535) to select the number of new history table entries.
Port
Select the specific port switch.
Buckets Requested
Enter the specific (1-50) number of samples to store.
Interval
Enter value in seconds (1 to 3600) to designate a specific interval time for the
collection of samples.
Owner
Enter the name of the owner of the RMON history group.
Apply
Click Apply to save the values and update the screen.
The ensuing table for History Information settings are informational only: Index, Port, Buckets
Requested, Interval, Owner and Delete (click to delete the desired index).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 131
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
RMON Alarm
The RMON Alarm page allows you to configure RMON statistics group and alarm groups. To
access this page, click Management > RMON > RMON Alarm.
Figure 4-102. Management > RMON > Rmon Alarm
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 132
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-100. Management > RMON > RMON Alarm
Item
Description
Index
Enter the index entry (1 to 65535) to define a specific Alarm Collection history entry.
Interval
Enter a value (1 to 2147483647) to define the interval value for the Alarm Collection
history.
Variable
Enter the alarm variables to define the monitoring triggers.
Sample Type
Enter the variable sample type.
Rising Threshold
Enter the rising alarm threshold trigger.
Falling Threshold Enter the falling alarm threshold trigger.
Rising Event Index Enter the rising event index (1-65535) to define the alarm group.
Falling Event Index Enter the falling event index (1-65535) to define the alarm group.
Owner
Enter the name of the owner of the RMON alarm group.
Apply Click
Apply to save the values and update the screen.
The ensuing table for Alarm Information settings are informational only: Index, Interval, Variable,
Sample Type, Rising Threshold, Falling Threshold, Rising Event Index, Falling Event Index, Owner
and Delete (click to delete the desired index).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 133
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
RMON Event
The RMON Event page is used to configure RMON event groups. To access this page, click
Management > RMON > RMON Event.
Figure 4-103. Management > RMON > RMON Event
Table 4-101. Management > RMON > RMON Event
Item
Description
Index
Enter the index entry (1 to 65535) to define a specific RMON event.
Description
Enter a value (1 to 2147483647) to define the interval value for the Alarm Collection
history.
Type
Click the drop-down menu to define the event type: None, Log, SNMP Trap, Log and Trap.
Community
Enter the community string to be passed for the specified event.
Owner
Enter the name of the owner of the RMON event.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Event Information settings are informational only: Index, Description, Type,
Community, Owner and Delete (click to delete the desired index).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 134
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.10 Diagnostics
Through the Diagnostics function configuration of settings for the switch diagnostics is available.
4.10.1 Cable Diagnostics
The Cable Diagnostics page allows you to select the port for applying a copper test. To access
this page, click Diagnostics > Cable Diagnostics.
Figure 4-104. Diagnostics > Cable Diagnostics
Table 4-102. Diagnostics > Cable Diagnostics
Item
Description
Port
Click the drop-down menu to select a pre-defined port for diagnostic testing. Giga ports
are displayed with a channel A to D designation.
Copper Test
Click Copper Test to display the test result for the selected port.
The ensuing table for Test Result settings are informational only: Port, Channel A, Cable Length A,
Channel B, Cable Length B, Channel C, Cable Length C, Channel D and Cable Length D.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 135
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.10.2 Ping Test
The Ping Test page allows you to configure the test log page. To access this page, click
Diagnostics > Ping Test.
Figure 4-105. Diagnostics > Ping Test
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 136
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-103. Diagnostics > Ping Test
Item
Description
IP Address
Enter the IP address or host name of the station to ping. The initial value is blank. The
IP Address or host name you enter is not retained across a power cycle. Host names are
composed of series of labels concatenated with periods. Each label must be between 1
and 63 characters long, maximum of 64 characters.
Count
Enter the number of echo requests to send. The default value is 4. The value ranges
from 1 to 5. The count entered is not retained across a power cycle.
Interval (in sec)
Enter the interval between ping packets in seconds. The default value is 1. The value
ranges from 1 to 5. The interval entered is not retained across a power cycle.
Size (in bytes)
Enter the size of ping packet. The default value is 56. The value ranges from 8 to 5120.
The size entered is not retained across a power cycle.
Ping Results
Display the reply format of ping.
PING 172.17.8.254 (172.17.8.254): 56 data bytes
--- 172.17.8.254 ping statistics --4 packets transmitted, 0 packets received, 100% packet loss Or
PING 172.17.8.93 (172.17.8.93): 56 data bytes
64 bytes from 172.17.8.93: icmp_seq=0 ttl=128 time=0.0 ms
64 bytes from 172.17.8.93: icmp_seq=1 ttl=128 time=0.0 ms
64 bytes from 172.17.8.93: icmp_seq=2 ttl=128 time=0.0 ms
64 bytes from 172.17.8.93: icmp_seq=3 ttl=128 time=0.0 ms
--- 172.17.8.93 ping statistics --4 packets transmitted, 4 packets received, 0% packet loss
round-trip min/avg/max = 0.0/0.0/0.0 ms
Apply
Click Apply to display ping result for the IP address.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 137
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.10.3 IPv6 Ping Test
The IPv6 Ping Test page allows you to configure the Ping Test for IPv6. To access this page, click
Diagnostics > IPv6 Ping Test.
Figure 4-106. Diagnostics > IPv6 Ping Test
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 138
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-104. Diagnostics > IPv6 Ping Test
Item
Description
IPv6 Address
Enter the IP address or host name of the station you want the switch to ping. The initial
value is blank. The IP Address or host name you enter is not retained across a power
cycle. Host names are composed of series of labels concatenated with dots. Each label
must be between 1 and 63 characters long, and the entire hostname has a maximum of
64 characters.
Count
Enter the number of echo requests you want to send. The default value is 4. The value
ranges from 1 to 5. The count you enter is not retained across a power cycle.
Interval (in sec) Enter the interval between ping packets in seconds. The default value is 1. The value
ranges from 1 to 5. The interval you enter is not retained across a power cycle.
Size (in bytes)
Enter the size of ping packet. The default value is 56. The value ranges from 8 to 5120.
The size you enter is not retained across a power cycle.
Ping Results
Display the reply format of ping.
PING 2222::777 (2222::777): 56 data bytes
--- 2222::777 ping statistics --4 packets transmitted, 0 packets received, 100% packet loss Or
PING 2222::717 (2222::717): 56 data bytes
64 bytes from 2222::717: icmp6_seq=0 ttl=128 time=10.0 ms
64 bytes from 2222::717: icmp6_seq=1 ttl=128 time=0.0 ms
64 bytes from 2222::717: icmp6_seq=2 ttl=128 time=0.0 ms
64 bytes from 2222::717: icmp6_seq=3 ttl=128 time=0.0 ms
--- 2222::717 ping statistics --4 packets transmitted, 4 packets received, 0% packet loss
round-trip min/avg/max = 0.0/2.5/10.0 ms
Apply
Click Apply to display ping result for the IP address.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 139
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.10.4 System Log
Logging Service
The Logging Service page allows you to setup the logging services feature for the system log.
To access this page, click Diagnostics > System Log > Logging Service.
Figure 4-107. Diagnostics > System Log > Logging Services
Table 4-105. Diagnostics > System Log > Logging Service
Item
Description
Logging Service
Click Enabled or Disabled to set the Logging Service status.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Logging Information settings are informational only: Logging Service.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 140
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Local Logging
The Local Logging page allows you to designate a local target when the severity criteria is
reached.
To access this page, click Diagnostics > System Log > Local Logging.
Figure 4-108. Diagnostics > System Log > Local Logging
Table 4-106. Diagnostics > System Log > Local Logging
Item
Description
Target
Enter the local logging target.
Severity
Click the drop-down menu to select the severity level for local log messages.
The level options are:
emerg: Indicates system is unusable. It is the highest level of severity
alert: Indicates action must be taken immediately
crit: Indicates critical conditions
error: Indicates error conditions
warning: Indicates warning conditions
notice: Indicates normal but significant conditions
info: Indicates informational messages
debug: Indicates debug-level messages
Apply
Click Apply to save the values and update the screen.
The ensuing table for Local Logging Settings Status settings are informational only: Status, Target,
Severity and Delete (click to delete the desired target).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 141
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
System Log Server
The System Log Server page allows you to configure the log server.
To access this page, click Diagnostics > System Log > System Log Server.
Figure 4-109. Diagnostics > System Log > System Log Server
Table 4-107. Diagnostics > System Log > System Log Server
Item
Description
Server Address
Enter the IP address of the log server.
Server Port
Enter the Udp port number of the log server.
Severity
Click the drop-down menu to select the severity level for local log messages. The
default is emerg.
The level options are:
· emerg: Indicates system is unusable. It is the highest level of severity
· alert: Indicates action must be taken immediately
· crit: Indicates critical conditions
· error: Indicates error conditions
· warning: Indicates warning conditions
· notice: Indicates normal but significant conditions
· info: Indicates informational messages
· debug: Indicates debug-level messages
Facility
Click the drop-down menu to select facility to which the message refers.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Remote Logging Setting Status settings are informational only: Status,
Server Info, Severity, Facility and Delete (click to delete the desired server address).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 142
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.10.5 DDM
The DDM page allows you to setup the diagnostic alarm status. To access this page, click
Diagnostics > DDM.
Figure 4-110. Diagnostics > DDM
Table 4-108. Diagnostics > DDM
Item
Description
Diagnostic
Alarm
Click the drop-down menu to designate the announcement method: Disabled, SysLog,
E-mail, or SNMP.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Diagnostic Alarm Information settings are informational only: Diagnostic
Alarm.
Figure 4-111. Diagnostics > DDM
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 143
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
Table 4-109. Diagnostics > DDM
Item
Description
High Alarm
Click Enabled or Disabled to set the alarm state.
High Warning
Click Enabled or Disabled to set the alarm state.
Low Alarm
Click Enabled or Disabled to set the alarm state.
Low Warning
Click Enabled or Disabled to set the alarm state.
Apply
Click Apply to save the values and update the screen.
The ensuing table for Vendor Info settings are informational only: Refresh (click to reload the
vendor information), Port, Connector, Speed, VendorName, VendorOui, VendorPn, VendorRev,
VendorSn and DateCode.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 144
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.11. Tools
4.11.1 IXM
The IXM tool is an industrial Ethernet switch solution to help the users deploy industrial Ethernet
switch hardware by allowing users with multiple, managed Ethernet switches in the field to
eliminate the need to individually connect to each device to configure it.
To access this page, click Tools > IXM.
Figure 4-112. Tools > IXM
Table 4-110. Tools > IXM
Item
Description
Search Field
Enter criteria to search the IXM information.
#
Displays the reference to the device number.
Device Name
Displays the device name.
Device Model
Displays the device model type.
Category
Displays the device’s category type.
IP Address
Displays the device’s IP address.
MAC Address
Displays the device’s IP MAC address.
Firmware Version
Displays the device’s firmware version.
Previous
Click Previous to back to previous page.
Next
Click Next to go to next page.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 145
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.11.2 Backup Manager
The Backup Manager page allows you to configure a remote TFTP sever or host file system in
order to backup the firmware image or configuration file.
To access this page, click Tools > Backup Manager.
Figure 4-113. Tools > Backup Manager
Table 4-111. Tools > Backup Manager
Item
Description
Backup Method Click the drop-down menu to select the backup method: TFTP or HTTP.
Server IP
Enter the IP address of the backup server.
Backup Type
Click a type to define the backup method: image: running configuration, startup
configuration, flash log, or buffered log.
Image
Click the format for the image type: 7428GE_2C_1_00_13.bix (Active) or vmlinux.bix
(backup).
Backup
Click Backup to backup the settings.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 146
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.11.3 Upgrade Manager
The Upgrade Manager page allows you to configure a remote TFTP sever or host file system in
order to upload firmware upgrade images or configuration files.
To access this page, click Tools > Upgrade Manager.
Figure 4-114. Tools > Upgrade Manager
Table 4-112. Tools > Upgrade Manager
Item
Description
Upgrade Method
Click the drop-down menu to select the upgrade method: TFTP or HTTP.
Server IP
Enter the IP address of the upgrade server.
File Name
Enter the file name of the new firmware version.
Upgrade Type
Click a type to define the upgrade method: image, startup configuration, or running
configuration.
Image
Click the format for the image type: 7428G_2C_1_00_13.bix (Active) or vmlinux.bix
(backup).
Upgrade
Click Upgrade to upgrade to the current version.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 147
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.11.4 Dual Image
The Dual Image page allows you to setup an active and backup partitions for firmware image
redundancy.
To access this page, click Tools > Dual Image.
Figure 4-115. Tools > Dual Image
Table 4-113. Tools > Dual Image
Item
Description
Active Image
Click the format for the image type: Partition0 (Active) or Partition1 (backup).
Save
Click Save to save and keep the new settings.
The ensuing table for Image Information 0/1 settings are informational only: Flash Partition, Image
Name, Image Size and Created Time.
4.11.5 Save Configuration
To access this page, click Tools > Save Configuration.
Click Save Configuration to FLASH to have configuration changes you have made to be saved
across a system reboot. All changes submitted since the previous save or system reboot will be
retained by the switch.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 148
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.11.6 User Account
The User Account page allows you to setup a user and the related parameters. To access this
page, click Tools > User Account.
Figure 4-116. Tools > User Account
Table 4-114. Tools > User Account
Item
Description
User Name
Enter the name of the new user entry.
Password Type
Click the drop-down menu to define the type of password: Clear Text, Encrypted or No
Password.
Password
Enter the character set for the define password type.
Retype Password
Retype the password entry to confirm the profile password.
Privilege Type
Click the drop-down menu to designate privilege authority for the user entry: Admin or
User.
Apply
Click Apply to create a new user account.
The ensuing table for Local Users settings are informational only: User Name, Password Type,
Privilege Type and Delete (click to delete the desired user account).
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 149
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
4.11.7 Reset System
To access this page, click Tools > Reset System.
Click Restore to have all configuration parameters reset to their factory default values. All changes
that have been made will be lost, even if you have issued a save.
Reset settings take effect after a system reboot.
4.11.8 Reboot Device
To access this page, click Tools > Reboot Device.
Click Reboot to reboot the switch. Any configuration changes you have made since the last time
you issued a save will be lost.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 150
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
APPENDIX
Troubleshooting
»» Verify that is using the right power cord/adapter (DC 12-48V), please don’t use the power
adapter with DC output higher than 48V, or it may damage this device.
»» Select the proper UTP/STP cable to construct the user network. Use unshielded twisted-pair
(UTP) or shield twisted-pair (STP) cable for RJ-45 connections that depend on the connector
type the switch equipped: 100R Category 3, 4 or 5 cable for 10Mbps connections, 100R
Category 5 cable for 100Mbps connections, or 100R Category 5e/ above cable for 1000Mbps
connections. Also be sure that the length of any twisted-pair connection does not exceed 100
meters (328 feet).
R = replacement letter for Ohm symbol.
»» Diagnosing LED Indicators: To assist in identifying problems, the switch can be easily
monitored through panel indicators, which describe common problems the user may
encounter and where the user can find possible solutions.
»» If the power indicator does not light on when the power cord is plugged in, you may have a
problem with power cord. Then check for loose power connections, power losses or surges at
power outlet. If you still cannot resolve the problem, contact the local dealer for assistance.
»» If the LED indicators are normal and the connected cables are correct but the packets still
cannot be transmitted. Please check the user system’s Ethernet devices’ configura­tion or status.
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 151
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 152
INSTALLATION AND OPERATION MANUAL
CNGE28FX4TX24MS(2,POE2/48)
INS_CNGE28FX4TX24MS(2,POE2/48)
TECH SUPPORT: 1.888.678.9427
04/30/18
PAGE 153
MECHANICAL INSTALLATION INSTRUCTIONS
ComNet Customer Service
Customer Care is ComNet Technology’s global service center, where our
professional staff is ready to answer your questions at any time.
Email ComNet Global Service Center: [email protected]
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA
T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | [email protected]
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE
T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]
© 2018 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement