- Home
- Home security & automation
- Security access control systems
- Gianni Industries
- DG-770TP
- Installation guide
Gianni Industries DG-770TP Touch Panel Keypad Installation Instruction
Add to my manuals
8 Pages
Gianni Industries DG-700 is a versatile access control system that combines the convenience of proximity card reading with the security of a keypad. It features 1,000 user codes and 10 cardholder IDs, making it suitable for both small offices and large commercial buildings. The DG-700 also offers two form C relays, each rated 10A@30VDC, allowing you to control electric locks, door strikes, or other access control devices. With its programmable output time, you can set the duration of relay activation from 1 to 99 seconds or toggle it for continuous operation.
advertisement
Split Series
Access Touch Keypad
with Proximity Card Reader
Installation & Programming
Manual
Model
DG-350
DG-700
DG-760
DG-770TP
Technology
EM 125KHz
Proximity
EM 125KHz
Proximity
EM 125KHz
Proximity
EM 125KHz
Proximity
Keypad Mount
Logo/
Trademark
Indicator
Light
Tactile Keys
Tactile Keys
Tactile Keys
Touch Panel
Single Gang
Surface/Flush
Poly Nameplate 3 LEDs
Single Gang
Surface
Mullion
Surface
Poly Nameplate
Multi-Colored
LED
Poly Nameplate
Multi-Colored
LED
Single Gang
Surface
Red LED
Display
3 LEDs
Split controller prevents magnetic interference with the access control unit to prevent unauthorized entry into the building
Please read the manual carefully before use this unit
◆
Features
• Accept power from a 12 or 24 Volt AC/DC supply
• Up to 1,000 user codes (000~999) programmable for output#1 and 10 (00~09) for output#2
• 2 Form C relays, each rated 10A@30VDC
• Each relay has programmable output time from 1~99 seconds or toggle
• Output #2 can be programmed for use with a door bell
• 2 Egress inputs for exiting the premises without keying in the code
• Split controller installation protects the keypad access from magnet tampering
• Tactile key feel and blue backlit 3×4 keypad for easy nighttime use (For DG-700/760)
• All features are programmed entirely from the keypad.
• Non-volatile EEPROM protects codes and instructions in case of power loss
• Tamper contact for added security (N.C. Dry contact, 100mA@12VDC max.)
• High strength design, epoxy potted, fully sealed within a zinc alloy housing
• Built-in RFID proximity reader
◆
Specifications
Operating Voltage
Model
Current draw
DG-700
DG-760
DG-770TP
DG-350
Relay
Outputs
Total max. current draw
Total max. current draw
Egress
Inputs
Total max. current draw
Total max. current draw
Operating Temperature
Proximity reader frequency
Proximity reader distance
12~24 VAC/VDC
Voltage
12VDC
24VDC
Holding
50mA
30mA
Pull in
103mA
56mA
Keypad
Light On
50mA
30mA
12VDC 50mA 95mA 50mA
24VDC 30mA 50mA
12VDC
24VDC
12VDC
24VDC
27mA
18mA
39mA
25mA
95mA
50mA
95mA
50mA
10mA@30VDC, Form C, NO/NC/COM
30mA
41mA
26mA
26mA
16mA
10mA@30VDC, Form C, NO/NC/COM
N.O. Ground
N.O. Ground
-4°~122°F (-20°~50°C)
125kHz
1.2” (3cm)
◆
Audible Indicators
Audible Tone
1 Long tone
1 Short tone
3 short tone
6 short + 1 long tone
Keypad Status
Confirmation
Key press
User code denied
All user codes deleted
Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13
◆
LED Indicators
LED
Steady Amber
Flashing Amber
Steady Green (Also flashing amber: DG-770TP)
Steady Red (Also flashing amber: DG-770TP)
Steady Green
Steady Red
Flashing Amber (6 flashes, for DG-770TP)
Keypad Status
Programming Mode
Waiting to programming entry
Waiting to program card/code
Card/Code already present
Relay 1 activated
Relay 2 activated
Reconnect power
◆
Dimensions
2 15/16” (76mm)
DG-350
DG-770TP
1 13/16”
(46.2mm)
1/8” (60.3mm)
2 3/4” (69.5mm)
1/4”
(6mm)
DG-760
1/8” (60.3mm)
2 3/4” (69.5mm)
DG-700
1/4”
(6mm)
7/8”
(22.7mm)
1/8” (60.3mm)
1/4”
(6mm)
3 1/16” (78.5mm)
2 3/4” (69.5mm)
7/8”
(22.8mm)
Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13
1/8”
(60.3mm)
1/4”
(6mm)
2 3/4” (69.5mm)
◆
Sample wiring and applications
Relay 2
Relay 1
INPUT
AC/DC
To Keypad To Keypad
Varistor
Electric Lock 2
Fail-safe Mode
12VDC Power Supply Unit
Exit Button 2
Diode
Electric Lock 1
Fail-secure Mode
12VDC Power Supply Unit
Exit Button1
REED
Door Closed = N.O.
Door Open = N.C.
Tamp(-)
(Anti-tamper alarm function is triggered at the same time)
12~24V Black Red Yellow Green
12 VDC Power Supply
Unit
12VDC
(Max Current 100mA )
Black Wire Cable
TAMP (-)
TAMP (+)
Extra Power Input to Emergency Light
(12/24 VAC/DC)
NC
COM
NO
V+
Model: CPT-710 Emergency Light
◆
Programming Instructions
1. Codes are programmed to be 4~6 digits in length. All codes must be the same length.
2. Before inputting any of the following, enter Programming Mode by entering the Master Code twice.
The default master code is 1234.
To enter Programming Mode, enter 1 2 3 4 1 2 3 4
3. To exit Programming Model, press the # key.
4. The keypad will exit Programming Mode if no keys are pressed for 30 seconds.
◆
Programming Tips
• Program a new Master Code immediately.
• Take note of the keypad status LED –
■
Right LED Solid Amber: Programming Mode
■
Middle LED Solid Green / Right LED Flashing Amber: Awaiting code/card entry
• If you are unsure of which mode the keypad is in, press # until the right LED is off. The keypad is now in
the Standby Mode. Enter the master code twice to return to Programming Mode..
Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13
◆
First Time Keypad Use
Take these steps the first time the keypad is programmed.
A. Enter Programming Mode
Enter 1 2 3 4 1 2 3 4 (Default Master Code is 1234)
B. Program Code Length
NOTE: To keep the default 4-digit code length, skip to step C, Program the Master Code.
WARNING: After a new code length is programmed, all user codes will be deleted and the master code will be reset.
1. Enter Programming Mode by entering the Master Code twice. (Default Master Code is 1234).
2. Enter 9 0 4
3. Enter the desire code length. This must be a number from 4~6.
4. Exit Programming Mode by pressing # .
The Master Code will reset depending on the programmed code length. These will be the new Master Codes
after the code length is reset:
Code Length
4 digits
5 digits
6 digits
New Master Code
1234
12345
123456
C. Program the Master Code
1. Enter Programming Mode by entering the Master Code twice. (Default Master Code is 1234).
2. Enter 3
3. Enter the new Master Code twice. The Master Code may not be the same as a user code.
Example: If the desired new Master Code is 4321, enter 4 3 2 1 4 3 2 1
4. Exit Programming Mode by pressing # .
D. Program the Master Card
In addition to a Master Code, a Master Card can also be programmed. Swiping a Master Card will give direct access to Programming Mode.
1. Enter Programming Mode by entering the Master Code twice. (Default Master Code
is 1234).
2. On the keypad, enter 7 .
3. If the middle LED is solid green and the right LED is flashing amber, a Master card is
already programmed. Clear it by entering . The keypad will beep in
confirmation, the middle LED will start flashing green and the right LED will start
flashing amber.
4. Swipe a proximity card. This card is now the Master Card.
5. Exit Programming Mode by pressing # .
Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13
E.
Setting the Output #1 Access Mode
DEFAULT: User card OR user code.
1. Enter Programming Mode by entering the Master Code twice.
3. Enter one of the following:
NOTE: Deleting all users is recommended before changing the access mode to user card with user code.
4. Exit Programming Mode by pressing .
◆
Programming Output #1:
Each Output #1 user can be programmed to have a user card, a user cord, or both user card and code.
NOTE: For all of the following programming functions, the keypad must be in Programming
Mode. To enter Programming Mode, enter the Master Code twice.
A. Program User Cards
2. If the left LED is red, previous user data exists. Clear it by entering . The keypad
will beep in confirmation and the middle LED will turn green.
3. Swipe a new user card.
4. To program the next user, repeat from step 1 in section A, B or C.
5. Exit Programming Mode by pressing .
B. Program User Codes
2. If the left LED is red, previous user data exists. Clear it by entering . The keypad will beep in confirmation
and the middle LED will turn green.
3. Enter a new user code.
4. To program the next user, repeat from step 1 in section A, B or C.
5. Exit Programming Mode by pressing .
C. Program Both User Cards and Codes
2. If the left LED is red, previous user data exists. Clear it by entering . The keypad
will beep in confirmation and the middle LED will turn green.
3. Swipe a new user card.
4. Enter a new user code.
5. To program the next user, repeat from step 1 in section A, B or C.
6. Exit Programming Mode by pressing .
◆
Programming Output #2:
Each Output #2 user may only have a user card or a user code programmed.
NOTE: For all of the following programming functions, the keypad must be in Programming
Mode. To enter Programming Mode, enter the Master Code twice.
Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13
A. Programming an Output #2 User Card
3. If the left LED is red, previous user data exists. Clear it by entering . . The keypad will
beep in confirmation and the middle LED will turn green.
4. Swipe a new user card.
5. To program the next user, repeat from step 2 in section A or B.
6. Return to Programming Mode by pressing .
7. Exit Programming Mode by pressing # again.
B. Programming an Output #2 User Code
3. If the left LED is red, previous user data exists. Clear it by entering . The keypad will
beep in confirmation and the middle LED will turn green.
4. Enter a new user code.
5. To program the next user, repeat from step 2 in section A or B.
6. Return to Programming Mode by pressing .
7. Exit Programming Mode by pressing # again.
◆
Deleting or changing users and cards:
Deleting or Changing the Master Card
Step 1 Enter: 7
Step 2 Delete the existing Master Card by entering:
Step 3 Swipe a new Master Card or Exit Programming Mode by entering .
Deleting or Changing an Output #1 User:
9 9 9
Step 2 Delete existing user by entering:
Programming Mode by entering .
Deleting or Changing an Output #2 User:
Step 1 Enter: 4
Step 2 Enter a user ID number: to 0 9
Step 2 Delete existing user by entering:
Programming Mode by entering .
◆
Using the Keypad:
Using a User Card with a User Code
• If Output #1 is programmed to accept a user card with a user code, swipe the user card.
Immediately enter the user code. This may be done in reverse order.
Wrong Code Lockout
• If a wrong code is entered or an invalid card is swiped 5 consecutive times, the keypad will
go into lockout for 1 minute. During this time, no codes can be entered and no card can be swiped.
(For DG-350 and DG-770TP, the keypad sounds 3 beeps and red LED flashes 3 times)
• Pushing buttons or swiping cards during lockout will extend the lockout time.
• When the keypad is reset to factory default state, keypad light flashes once for code re-entry.
(For DG-350 and DG-770TP)
Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13
◆
Additional Progrmming:
Programming the Output# 1 Timer
DEFAULT: 1 second
Step 1 Enter: 1
Step 2 For toggle mode, enter or for timed output, enter to 9 9
01 to 99 is the number of seconds Output #1 will actovate
Programming the Output# 2 Timer
DEFAULT: 1 second
Step 1 Enter: 5
01 to 99 is the number of seconds Output #1 will activate
9 9
Programming the Output# 2 Function
Output #2 can be activated via * or through user codes. Use the following steps to program its function.
DEFAULT: User Codes
Step 1 Enter: 2
0 2
When output #2 is programmed for doorbell, press to activate doorbell. Doorbell output lasts 1 second.
◆
RESETTING THE KEYPAD:
NOTE: Resstting the keypad will cause some or all programmed data to be lost. Do not perform either of these steps unless it is absolutely necessary.
Deleting All Users: Enter 8 8 8
IMPORTANT: Once key entry is made, all user cards and user codes will be deleted and the keypad will return to Programming Mode. The Master Code and all other programming settings will remain the same.
Restore Factory Settings: Enter 8 9 9
IMPORTANT: Once key entry is made, keypad will return to factory default settings. No user information will be retained and the Master Code will be 1234.
◆
MANUALLY RESETTING THE MASTER CODE:
If the Master Code has been forgotten or does no work, the following steps can be taken to reset the Master Code:
1. Disconnect power from the keypad.
2. Press the key continuously and connect power again.
3. The keypad will beep to confirm a successful reset.
Note: Manually resetting the Master Code will only reset the Master Code. It will not affect the Master Card, User Code or any other saved data.