Gianni Industries DG-770TP Touch Panel Keypad Installation Instruction


Add to my manuals
8 Pages

advertisement

Gianni Industries DG-770TP Touch Panel Keypad Installation Instruction | Manualzz

Split Series

Access Touch Keypad

with Proximity Card Reader

Installation & Programming

Manual

Model

DG-350

DG-700

DG-760

DG-770TP

Technology

EM 125KHz

Proximity

EM 125KHz

Proximity

EM 125KHz

Proximity

EM 125KHz

Proximity

Keypad Mount

Logo/

Trademark

Indicator

Light

Tactile Keys

Tactile Keys

Tactile Keys

Touch Panel

Single Gang

Surface/Flush

Poly Nameplate 3 LEDs

Single Gang

Surface

Mullion

Surface

Poly Nameplate

Multi-Colored

LED

Poly Nameplate

Multi-Colored

LED

Single Gang

Surface

Red LED

Display

3 LEDs

Split controller prevents magnetic interference with the access control unit to prevent unauthorized entry into the building

Please read the manual carefully before use this unit

Features

• Accept power from a 12 or 24 Volt AC/DC supply

• Up to 1,000 user codes (000~999) programmable for output#1 and 10 (00~09) for output#2

• 2 Form C relays, each rated 10A@30VDC

• Each relay has programmable output time from 1~99 seconds or toggle

• Output #2 can be programmed for use with a door bell

• 2 Egress inputs for exiting the premises without keying in the code

• Split controller installation protects the keypad access from magnet tampering

• Tactile key feel and blue backlit 3×4 keypad for easy nighttime use (For DG-700/760)

• All features are programmed entirely from the keypad.

• Non-volatile EEPROM protects codes and instructions in case of power loss

• Tamper contact for added security (N.C. Dry contact, 100mA@12VDC max.)

• High strength design, epoxy potted, fully sealed within a zinc alloy housing

• Built-in RFID proximity reader

Specifications

Operating Voltage

Model

Current draw

DG-700

DG-760

DG-770TP

DG-350

Relay

Outputs

Total max. current draw

Total max. current draw

Egress

Inputs

Total max. current draw

Total max. current draw

Operating Temperature

Proximity reader frequency

Proximity reader distance

12~24 VAC/VDC

Voltage

12VDC

24VDC

Holding

50mA

30mA

Pull in

103mA

56mA

Keypad

Light On

50mA

30mA

12VDC 50mA 95mA 50mA

24VDC 30mA 50mA

12VDC

24VDC

12VDC

24VDC

27mA

18mA

39mA

25mA

95mA

50mA

95mA

50mA

10mA@30VDC, Form C, NO/NC/COM

30mA

41mA

26mA

26mA

16mA

10mA@30VDC, Form C, NO/NC/COM

N.O. Ground

N.O. Ground

-4°~122°F (-20°~50°C)

125kHz

1.2” (3cm)

Audible Indicators

Audible Tone

1 Long tone

1 Short tone

3 short tone

6 short + 1 long tone

Keypad Status

Confirmation

Key press

User code denied

All user codes deleted

Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13

LED Indicators

LED

Steady Amber

Flashing Amber

Steady Green (Also flashing amber: DG-770TP)

Steady Red (Also flashing amber: DG-770TP)

Steady Green

Steady Red

Flashing Amber (6 flashes, for DG-770TP)

Keypad Status

Programming Mode

Waiting to programming entry

Waiting to program card/code

Card/Code already present

Relay 1 activated

Relay 2 activated

Reconnect power

Dimensions

2 15/16” (76mm)

DG-350

DG-770TP

1 13/16”

(46.2mm)

1/8” (60.3mm)

2 3/4” (69.5mm)

1/4”

(6mm)

DG-760

1/8” (60.3mm)

2 3/4” (69.5mm)

DG-700

1/4”

(6mm)

7/8”

(22.7mm)

1/8” (60.3mm)

1/4”

(6mm)

3 1/16” (78.5mm)

2 3/4” (69.5mm)

7/8”

(22.8mm)

Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13

1/8”

(60.3mm)

1/4”

(6mm)

2 3/4” (69.5mm)

Sample wiring and applications

Relay 2

Relay 1

INPUT

AC/DC

To Keypad To Keypad

Varistor

Electric Lock 2

Fail-safe Mode

12VDC Power Supply Unit

Exit Button 2

Diode

Electric Lock 1

Fail-secure Mode

12VDC Power Supply Unit

Exit Button1

REED

Door Closed = N.O.

Door Open = N.C.

Tamp(-)

(Anti-tamper alarm function is triggered at the same time)

12~24V Black Red Yellow Green

12 VDC Power Supply

Unit

12VDC

(Max Current 100mA )

Black Wire Cable

TAMP (-)

TAMP (+)

Extra Power Input to Emergency Light

(12/24 VAC/DC)

NC

COM

NO

V+

Model: CPT-710 Emergency Light

Programming Instructions

1. Codes are programmed to be 4~6 digits in length. All codes must be the same length.

2. Before inputting any of the following, enter Programming Mode by entering the Master Code twice.

The default master code is 1234.

To enter Programming Mode, enter 1 2 3 4 1 2 3 4

3. To exit Programming Model, press the # key.

4. The keypad will exit Programming Mode if no keys are pressed for 30 seconds.

Programming Tips

• Program a new Master Code immediately.

• Take note of the keypad status LED –

Right LED Solid Amber: Programming Mode

Middle LED Solid Green / Right LED Flashing Amber: Awaiting code/card entry

• If you are unsure of which mode the keypad is in, press # until the right LED is off. The keypad is now in

the Standby Mode. Enter the master code twice to return to Programming Mode..

Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13

First Time Keypad Use

Take these steps the first time the keypad is programmed.

A. Enter Programming Mode

Enter 1 2 3 4 1 2 3 4 (Default Master Code is 1234)

B. Program Code Length

NOTE: To keep the default 4-digit code length, skip to step C, Program the Master Code.

WARNING: After a new code length is programmed, all user codes will be deleted and the master code will be reset.

1. Enter Programming Mode by entering the Master Code twice. (Default Master Code is 1234).

2. Enter 9 0 4

3. Enter the desire code length. This must be a number from 4~6.

4. Exit Programming Mode by pressing # .

The Master Code will reset depending on the programmed code length. These will be the new Master Codes

after the code length is reset:

Code Length

4 digits

5 digits

6 digits

New Master Code

1234

12345

123456

C. Program the Master Code

1. Enter Programming Mode by entering the Master Code twice. (Default Master Code is 1234).

2. Enter 3

3. Enter the new Master Code twice. The Master Code may not be the same as a user code.

Example: If the desired new Master Code is 4321, enter 4 3 2 1 4 3 2 1

4. Exit Programming Mode by pressing # .

D. Program the Master Card

In addition to a Master Code, a Master Card can also be programmed. Swiping a Master Card will give direct access to Programming Mode.

1. Enter Programming Mode by entering the Master Code twice. (Default Master Code

is 1234).

2. On the keypad, enter 7 .

3. If the middle LED is solid green and the right LED is flashing amber, a Master card is

already programmed. Clear it by entering . The keypad will beep in

confirmation, the middle LED will start flashing green and the right LED will start

flashing amber.

4. Swipe a proximity card. This card is now the Master Card.

5. Exit Programming Mode by pressing # .

Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13

E.

Setting the Output #1 Access Mode

DEFAULT: User card OR user code.

1. Enter Programming Mode by entering the Master Code twice.

3. Enter one of the following:

NOTE: Deleting all users is recommended before changing the access mode to user card with user code.

4. Exit Programming Mode by pressing .

Programming Output #1:

Each Output #1 user can be programmed to have a user card, a user cord, or both user card and code.

NOTE: For all of the following programming functions, the keypad must be in Programming

Mode. To enter Programming Mode, enter the Master Code twice.

A. Program User Cards

2. If the left LED is red, previous user data exists. Clear it by entering . The keypad

will beep in confirmation and the middle LED will turn green.

3. Swipe a new user card.

4. To program the next user, repeat from step 1 in section A, B or C.

5. Exit Programming Mode by pressing .

B. Program User Codes

2. If the left LED is red, previous user data exists. Clear it by entering . The keypad will beep in confirmation

and the middle LED will turn green.

3. Enter a new user code.

4. To program the next user, repeat from step 1 in section A, B or C.

5. Exit Programming Mode by pressing .

C. Program Both User Cards and Codes

2. If the left LED is red, previous user data exists. Clear it by entering . The keypad

will beep in confirmation and the middle LED will turn green.

3. Swipe a new user card.

4. Enter a new user code.

5. To program the next user, repeat from step 1 in section A, B or C.

6. Exit Programming Mode by pressing .

Programming Output #2:

Each Output #2 user may only have a user card or a user code programmed.

NOTE: For all of the following programming functions, the keypad must be in Programming

Mode. To enter Programming Mode, enter the Master Code twice.

Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13

A. Programming an Output #2 User Card

3. If the left LED is red, previous user data exists. Clear it by entering . . The keypad will

beep in confirmation and the middle LED will turn green.

4. Swipe a new user card.

5. To program the next user, repeat from step 2 in section A or B.

6. Return to Programming Mode by pressing .

7. Exit Programming Mode by pressing # again.

B. Programming an Output #2 User Code

3. If the left LED is red, previous user data exists. Clear it by entering . The keypad will

beep in confirmation and the middle LED will turn green.

4. Enter a new user code.

5. To program the next user, repeat from step 2 in section A or B.

6. Return to Programming Mode by pressing .

7. Exit Programming Mode by pressing # again.

Deleting or changing users and cards:

Deleting or Changing the Master Card

Step 1 Enter: 7

Step 2 Delete the existing Master Card by entering:

Step 3 Swipe a new Master Card or Exit Programming Mode by entering .

Deleting or Changing an Output #1 User:

9 9 9

Step 2 Delete existing user by entering:

Programming Mode by entering .

Deleting or Changing an Output #2 User:

Step 1 Enter: 4

Step 2 Enter a user ID number: to 0 9

Step 2 Delete existing user by entering:

Programming Mode by entering .

Using the Keypad:

Using a User Card with a User Code

• If Output #1 is programmed to accept a user card with a user code, swipe the user card.

Immediately enter the user code. This may be done in reverse order.

Wrong Code Lockout

• If a wrong code is entered or an invalid card is swiped 5 consecutive times, the keypad will

go into lockout for 1 minute. During this time, no codes can be entered and no card can be swiped.

(For DG-350 and DG-770TP, the keypad sounds 3 beeps and red LED flashes 3 times)

• Pushing buttons or swiping cards during lockout will extend the lockout time.

• When the keypad is reset to factory default state, keypad light flashes once for code re-entry.

(For DG-350 and DG-770TP)

Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13

Additional Progrmming:

Programming the Output# 1 Timer

DEFAULT: 1 second

Step 1 Enter: 1

Step 2 For toggle mode, enter or for timed output, enter to 9 9

01 to 99 is the number of seconds Output #1 will actovate

Programming the Output# 2 Timer

DEFAULT: 1 second

Step 1 Enter: 5

01 to 99 is the number of seconds Output #1 will activate

9 9

Programming the Output# 2 Function

Output #2 can be activated via * or through user codes. Use the following steps to program its function.

DEFAULT: User Codes

Step 1 Enter: 2

0 2

When output #2 is programmed for doorbell, press to activate doorbell. Doorbell output lasts 1 second.

RESETTING THE KEYPAD:

NOTE: Resstting the keypad will cause some or all programmed data to be lost. Do not perform either of these steps unless it is absolutely necessary.

Deleting All Users: Enter 8 8 8

IMPORTANT: Once key entry is made, all user cards and user codes will be deleted and the keypad will return to Programming Mode. The Master Code and all other programming settings will remain the same.

Restore Factory Settings: Enter 8 9 9

IMPORTANT: Once key entry is made, keypad will return to factory default settings. No user information will be retained and the Master Code will be 1234.

MANUALLY RESETTING THE MASTER CODE:

If the Master Code has been forgotten or does no work, the following steps can be taken to reset the Master Code:

1. Disconnect power from the keypad.

2. Press the key continuously and connect power again.

3. The keypad will beep to confirm a successful reset.

Note: Manually resetting the Master Code will only reset the Master Code. It will not affect the Master Card, User Code or any other saved data.

Copyright © All rights reserved. P-MU-DG-7Series Published 2019.06.13

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement