Wacker Neuson DPU90rLem770 US Reversible Vibratory Plate Operator's Manual

Add to My manuals
16 Pages

advertisement

Wacker Neuson DPU90rLem770 US Reversible Vibratory Plate Operator's Manual | Manualzz

Manual for the machine configuration

Vibratory plate

DPU

80, 90, 110

Model

Document

Issue

Version

Language

DPU

5100018593

11.2019

05 en

Copyright © 2019 Wacker Neuson Produktion GmbH & Co. KG

Printed in Germany

All rights are reserved, in particular the worldwide applicable copyright, right of duplication and right of distribution.

This document may only be used by the recipient for the intended purpose. The document may not be reproduced entirely or partially, or translated into any other language.

Reproduction or translation, even extracts thereof, only with written approval of Wacker Neuson

Produktion GmbH & Co. KG.

Any breach of the statutory regulations, in particular the protection of copyright, will lead to civil and criminal prosecution.

Wacker Neuson Produktion GmbH & Co. KG is constantly working on the improvement of its products as part of the technical further development. Therefore, we reserve the right to make changes to the illustrations and descriptions in this documentation without incurring any obligation to make changes to machines already delivered.

Errors excepted.

The machine on the cover may have special equipment (options).

Manufacturer

Wacker Neuson Produktion GmbH & Co. KG

Wackerstraße 6

D-85084 Reichertshofen www.wackerneuson.com

Tel.: +4984533403200

E-Mail: [email protected]

Original operator's manual

100_0000_0001.fm

Table of contents

1

2

3

4

5

Preface

.................................................................................................................................... 4

Introduction

............................................................................................................................ 5

2.1

Explanation of symbols................................................................................................................ 5

2.2

Wacker Neuson Contact partner ................................................................................................. 5

Operation of the configuration menu

.................................................................................. 6

3.1

Accessing the configuration menu............................................................................................... 6

3.2

Change the activation PIN ........................................................................................................... 7

3.3

Setting the turn-off time (in drawbar mode) ................................................................................. 8

3.4

Setting the language.................................................................................................................... 8

3.5

Setting the overload sensor ......................................................................................................... 9

3.5.1

Software status 10........................................................................................... 10

3.5.2

Software status 11........................................................................................... 10

3.6

Activate Compamatic................................................................................................................. 10

3.7

Hydraulic parameters................................................................................................................. 10

3.8

Changing the setup PIN............................................................................................................. 11

3.9

Exiting the configuration menu .................................................................................................. 11

Troubleshooting

..................................................................................................................12

4.1

Fault table .................................................................................................................................. 12

PIN data

................................................................................................................................ 13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

5100018593IVZ.fm

3

1 Preface

1 Preface

This manual describes the possible settings and the operation of the configuration menu on the machine's display. In addition, this manual includes the PIN data of this machine that was set ex factory.

This manual is intended exclusively for the machine's licensee and not for the operator. Store this manual in a place that is secured against unauthorized access.

This manual is a supplement to the operator's manual and only contains notes regarding the operation of the configuration menu.

Also observe the notes in the operator's manual of the machine.

4

100_0000_0018.fm

2 Introduction

2 Introduction

2.1

Explanation of symbols

This manual contains specially emphasized safety instructions in the following categories: DANGER,

WARNING, CAUTION and NOTICE.

Before performing any work on or with this machine, the notes and safety instructions must be read and understood. All notes and safety instructions in this manual must be passed on to the maintenance, repair, and transport personnel.

DANGER

This combination of symbol and signal word indicates a hazardous situation that will lead to death or serious injury if it is not avoided.

WARNING

This combination of symbol and signal word indicates a hazardous situation that can lead to death or serious injury if it is not avoided.

2.2

CAUTION

This combination of symbol and signal word indicates a hazardous situation that can lead to minor injury or damage to the machine if it is not avoided.

NOTICE

Supplementary information.

Wacker Neuson Contact partner

Depending on the country, the Wacker Neuson contact partner is a Wacker Neuson service department, a Wacker Neuson affiliate, or a Wacker Neuson dealer.

On the Internet at www.wackerneuson.com

.

The manufacturer's address can be found at the beginning of this manual.

100_0000_0019.fm

5

3 Operation of the configuration menu

3 Operation of the configuration menu

NOTICE:

The overload sensor cannot be set in the coupling set (= coupling mode).The value 0 is set.

The machine has a system for the machine configuration, which can be used to adapt certain machine settings to the operating company's requirements.

1

2

3

3.1

Item Designation

1 Display - configuration menu

2 On/Off switch (red)

Item Designation

3 Setting button (black)

Setting options in the configuration menu

In the configuration menu on the display, the following machine settings can be adjusted:

Change/activate/deactivate activation PIN of the machine.

Setting turn-off time of the machine.

Select the display language (English, German, French, or Spanish).

Adjust machine response in the case of overload (overload sensor).

Setting the Compamatic option.

Setting the hydraulic parameters/centrifugal force.

Change setup PIN.

Operator's controls

With the ON/OFF switch on the machine, you can switch from one menu item to the next menu item and from one digit to the next digit.

The value of a digit can be changed with the adjusting button.

Accessing the configuration menu

CAUTION!

Unintentional changing of settings.

The changed settings are always changed when the setup menu is left.

 If settings have been changed unintentionally and these should not be saved, switch off the machine with the emergency stop switch.

NOTICE:

The access to the configuration menu is secured by the setup PIN.

1. Activate machine.

2. Hold down the ON/OFF switch on the machine and simultaneously the setting button on the machine for at least 3 seconds.

6

100_0202_op_0013.fm

3 Operation of the configuration menu

3. The following text will appear on the display:

Hold down the button and wait...

Setup

Menu

4. The following text will appear on the display after about 2 seconds:

Setup PIN

Enter PIN

5. If the following text appears on the display, enter the setup PIN with the setting button and then press the ON/OFF switch on the machine.

Enter PIN

0000

Enter the value of the first digit with the setting button.

Change to the next digit with the ON/OFF switch.

Enter the entire PIN.

Value

8946

0001 to 9999

Setup PIN

Setup PIN input enabled (factory default setting)

Possible setup PIN combinations

3.2

NOTICE:

If the setup PIN has been entered incorrectly, an error message will appear on the display.

In this case, press the ON/OFF switch to be able to make a new entry.

6. If the following text appears on the display after a successful setup PIN entry, press the ON/OFF switch on the machine.

In the configuration menu:

Settings can be changed here or you can simply scroll through the configuration menu with the ON/OFF switch in order to check the settings.

Change the activation PIN

An activation PIN can be set, which secures the machine against unauthorized operation. After activating the machine, the operator has to enter the activation PIN.

1. Press the ON/OFF switch on the machine until the following text appears on the display:

Activation PIN

0000

100_0202_op_0013.fm

7

3 Operation of the configuration menu

3.3

2. The activation PIN can be changed.

 Enter the value of the first digit with the setting button.

Change to the next digit with the ON/OFF switch.

Enter the entire PIN.

Value

0000

0001 to 9999

Activation PIN

Activation PIN input disabled (factory default setting)

Possible activation PIN combinations

3. Repeat the activation PIN

4. A confirmation appears that the activation PIN has been changed.

Setting the turn-off time (in drawbar mode)

NOTICE:

The turn-off time cannot be set in the coupling set (= coupling mode).The value 4 is set.

A time duration can be selected after which the machine is automatically deactivated if it no longer receives a control command from the remote control or the engine is off.

1. Press the ON/OFF switch on the machine until the following text appears on the display:

3.4

Turn-off time

1 h

2. The turn-off time can be set:

 Enter the value of the first digit with the setting button.

Value Turn-off time

0.25

0.25 hours (factory default setting for center pole machines)

1

2

1 hour (factory default setting for remote control machines)

2 h

3

4

3 h

4 h

Setting the language

The display language can be adjusted.

1. Press the ON/OFF switch on the machine until the following text appears on the display:

Select language

0=DE

8

100_0202_op_0013.fm

3.5

3 Operation of the configuration menu

2. The language can be adjusted:

 Enter the value of the first digit with the setting button.

10

11

12

8

9

6

7

Value Language

0

1

DE German (factory default setting EU machines)

EN English (factory default setting US machines)

4

5

2

3

FR French

ES Spanish

EN (UK) English UK

SV Swedish

FI Finnish

NO Norwegian

DA Danish

NL Dutch

PL Polish

CS Czech

RU Russian

Setting the overload sensor

The machine's overload sensor detects when the machine is working on hard soil that cannot be compacted further. To protect the machine from damage, you can set how the machine is to react in the event of overload.

1. Press the ON/OFF switch on the machine until the following text appears on the display:

Overload sensor

0

2. The machine's response in the event of an overload can be set.

 Enter the value of the first digit with the setting button.

NOTICE:

Software status can be read out in the diagnostics menu, see operator's manual for the machine, chapter Components and operator's controls.

100_0202_op_0013.fm

9

3 Operation of the configuration menu

3.5.1

Software status 10

Value Overload sensor

0 The receiving units/control lamp on the center pole flash red quickly. After more than 10 seconds of overload, an entry is made in the error memory (error code 13). It is possible to operate the machine despite an overload.

1 (Factory default setting)

The receiving units/control lamp on the center pole flash red quickly. No entry is made in the machine's error memory. The machine immediately reduces the compaction performance in the event of an overload.

2

3

The receiving units/control lamp on the center pole flash red quickly. After more than 6 seconds of overload, an entry is made in the error memory (error code 12). After more than 6 seconds of overload, the engine is switched off.

The receiving units/control lamp on the center pole flash red quickly. No entry is made in the machine's error memory. In the event of an overload, the machine immediately switches to slow operation (engine idling) and reduces the compaction performance.

3.5.2

Software status 11

3.6

Value Overload sensor

0

1

The receiving units/control lamp on the center pole flash red quickly. After more than 10 seconds of overload, an entry is made in the error memory (error code 13). It is possible to operate the machine despite an overload.

The receiving units/control lamp on the center pole flash red quickly. No entry is made in the machine's error memory. The machine immediately reduces the compaction performance in the event of an overload.

2

3

The receiving units/control lamp on the center pole flash red quickly. After more than 6 seconds of overload, an entry is made in the error memory (error code 12). After more than 6 seconds of overload, the engine is switched off.

(Factory default setting)

The receiving units/control lamp on the center pole flash red quickly. No entry is made in the machine's error memory. In the event of an overload, the machine immediately switches to slow operation (engine idling) and reduces the compaction performance.

Activate Compamatic

1. Press the ON/OFF switch on the machine until the following text appears on the display:

Compamatic

0

3.7

Value Compamatic

0

1

Deactivated

Activated

Hydraulic parameters

The following menu items have a factory default setting. These settings should only be changed by the service department of the Wacker Neuson contact partner.

Center pole machines

 Hydraulic parameters.

 L: 100%, H: 100%*

10

100_0202_op_0013.fm

3.8

3 Operation of the configuration menu

Remote controlled machines

Hydraulic parameters T:

 All values are at 0.

Hydraulic parameter Z:

 All values are at 0.

Changing the setup PIN

The setup PIN locks access to the configuration menu.

The setup PIN assigned ex factory can be changed.

NOTICE:

Never deactivate the setup PIN, as the configuration menu will no longer be protected against unauthorized changes.

1. Press the ON/OFF switch on the machine until the following text appears on the display:

3.9

Setup PIN

8946

Enter the value of the first digit with the setting button.

Change to the next digit with the ON/OFF switch.

Enter the entire PIN.

Value

8946

0000

0001 to 9999

Setup PIN

Factory default setting

Setup PIN disabled

Possible setup PIN combinations

2. Repeat the activation PIN

3. A confirmation appears that the activation PIN has been changed.

Exiting the configuration menu

1. Press the ON/OFF switch on the machine for 3 seconds.

2. Deactivate machine.

NOTICE:

When exiting the configuration menu, the changed settings will automatically be saved.

So that the changed settings are effective, the machine has to be deactivated once and then reactivated again.

100_0202_op_0013.fm

11

4 Troubleshooting

4 Troubleshooting

4.1

Fault table

DANGER

Danger to life from unauthorized troubleshooting.

 If faults occur with this machine that are not described in this manual, contact the manufacturer. Do not eliminate the faults independently.

Fault

The configuration menu cannot be accessed.

Possible causes

Machine was not activated.

ON/OFF switch and setting button of the machine not pushed long enough.

Remedial measure

Activate the machine and wait until the display shows the operating hours.

Hold down the ON/OFF switch and simultaneously the setting button on the machine for 3 seconds.

12

100_0202_ts_0012.fm

5 PIN data

The following table includes PIN data set ex factory.

Note the modified PIN data in the following table:

Serial number

PIN

0000

(PIN query disabled)

Setup PIN

8946

Modified on Date

Factory default setting

5 PIN data

NOTICE

If the PIN was forgotten, the machine can also be unlocked with the setup PIN.

If the PIN and the setup PIN were forgotten, however, the machine can no longer be unlocked. In this case, please contact the service department of the Wacker Neuson contact partner.

100_0202_ot_0006.fm

13

5 PIN data

14

100_0202_ot_0006.fm

advertisement