Danfoss SC21F Standard Compressor R134a 220-240V 50Hz Data Sheet


Add to my manuals
2 Pages

advertisement

Danfoss SC21F Standard Compressor R134a 220-240V 50Hz Data Sheet | Manualzz

SC21F

Standard Compressor

R134a

220-240V 50Hz

Compressors

Data Sheet (Replaces CD.44.X2.02)

General

Compressor

Code number

Code number compressor with oil cooler

SC21F

104G8100

104G8110

Application

Application

Evaporating temperature range

Voltage range

°C

V/Hz

LBP * )

-35 to -5

198 - 254 /50

Motor type

Max. ambient temperature

Comp. cooling at ambient temp.

°C

32°C

38°C

CSIR

38

O/F

1

O/F

1

* ) Can be used as a HBP compressor with 240V 50Hz mains (216-254V).

Design

Displacement

Oil quantity

Maximum refrigerant charge

Free gas vol. in compressor

Weight without electrical equipment cm 3 20.95

cm 3 550 (500 on comp. with oil cooler)

g cm 3

kg

1300

1460

13.3

Application

SC21F

R134a

Blue stripe

Approvals

Barcode on white background

Yellow background

104G

8110

DANFOSS COMPRESSORS

S = Static cooling normally sufficient

O = Oil cooling

F

1

= Fan cooling 1.5 m/s

(compressor compartment temperature

F

2 equal to ambient temperature)

= Fan cooling 3.0 m/s necessary

ø16

204

178

170

ø19

ø9.7

Motor

Motor size

LRA (rated after 4 sec. UL984) HST watt

A

Cut-in current HST A

Resistance, main and start winding (25°C) Ω

Approvals

495

18.6

18.6

3.7/14.1

EN 60335-2-34

D

127

165

186

218

C

Dimensions

Height

E

Suction connector

Process connector

Discharge connector

Oil cooler

Compressors on a pallet mm A

B

B1

B2 location/I.D. mm C location/I.D. mm D location/I.D. mm E location/I.D. mm F pcs.

219

213

193

110

10.2 ±0.09

6.2 ±0.09

6.2 ±0.09

6.2 ±0.09

80

B1

30 15

255

F

B2

B A

37° 37°

107 107

115

8264

August 2003 CD.44.X3.02

1

Capacity (EN 12900/CECOMAF) watt

C o m p .

\ ° C

S C 2 1 F

3 5

1 8 5

3 0

2 4 5

2 5

3 3 5

2 3 .

3

3 7 5

2 0

4 5 5

1 5

6 1 0

1 0

7 8 0

5

9 9 0

Capacity (ASHRAE) watt

C o m p .

\ ° C

S C 2 1 F

3 5

2 2 8

3 0

3 0 2

2 5

4 1 2

2 3 .

3

4 6 2

2 0

5 6 0

1 5

7 5 0

1 0

9 6 0

5

1 2 2 0

Power consumption watt

C o m p .

\ ° C

S C 2 1 F

3 5

2 7 5

3 0

3 2 5

2 5

3 8 0

2 3 .

3

4 0 5

2 0

4 5 0

1 5

5 2 0

1 0

6 0 0

5

6 8 5

Current consumption A

C o m p .

\ ° C

S C 2 1 F

3 5

2 .

5 0

3 0

2 .

6 4

2 5

2 .

7 7

2 3 .

3

2 .

8 1

2 0

2 .

9 2

1 5

3 .

1 6

1 0

3 .

5 3

5

4 .

0 9

COP (EN 12900/CECOMAF) W/W

C o m p .

\ ° C

S C 2 1 F

3 5

0 .

6 7

3 0

0 .

7 5

2 5

0 .

8 8

2 3 .

3

0 .

9 2

2 0

1 .

0 1

1 5

1 .

1 7

1 0

1 .

3 0

5

1 .

4 5

COP (ASHRAE) W/W

C o m p .

\ ° C

S C 2 1 F

3 5

0 .

8 3

3 0

0 .

9 3

2 5

1 .

0 8

2 3 .

3

1 .

1 4

2 0

1 .

2 4

1 5

1 .

4 4

1 0

1 .

6 0

5

1 .

7 8

Test conditions

Condensing temperature

Ambient and suction gas temp.

Liquid temperature

Fan cooling, 220V 50Hz

EN 12900/CECOMAF

55°C

32°C

55°C

ASHRAE

55°C

32°C

32°C c b

8222 d a2

10

12

14

13

11 c

Main winding

Winding protector

Start winding

Accessories

D e v i c e s

S t a r t i n g r e l a y

C o v e r

S t a r t i n g c a p a c i t o r 8 0

µ

F

C o r d r e il e f

M o u n t i n g a c c e s s o r i e s

B o l t

B o l t j o i n t j o i n t f o r i n q o n e u a n c t i o m t i e s p r e s s o r

S n a p o n i n q u a n t i t i e s

F i g .

a 2 b c d

S C 2 1 F

1 1 7 U 6 0 1 9

1 0 3 N 2 0 0 9

1 1 7 U 5 0 1 7

1 0 3 N 1 0 0 4

1 1 8 1 9 1 7

1 1 8 1 9 1 8

1 1 8 1 9 1 9

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2 CD.44.X3.02

August 2003

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement