advertisement
Data Sheet
Danfoss Gas Sensor (DGS)
Introduction
DGS sensors can be used in stand-alone or integrated systems, where continuous real-time, automatic monitoring with Danfoss ADAP-KOOL® Refrigeration Control & Monitoring System and/or
Building Management Systems is applied.
DGS supports our Customers in complying to environmental F-Gas Regulations and Health &
Safety requirements, on new or existing systems in:
• Supermarkets
• Process refrigeration plants
• Refrigerated storage and warehousing
• Special application areas/zones
Typical Refrigerant gas applications include:
• Halocarbons: HFC’s, HCFC’s, CFCs.
• Carbon Dioxide (CO₂/R744)
• Hydrocarbons (e.g. R290)
• Other special application gases to customer request
Sensing technology varies to make the best detection for a given gas, in terms of performance and cost. DGS IR is based on Infra-Red sensor technology, DGS SC is based on Semi-Conductor and DGS-PE is based on Pellistor.
© Danfoss | DCS (ADAP-KOOL®) |2018-12 RD8CN202 | 1
Technical Data
Power Supply 24 V DC ± 20 % ; reverse polarity protected
24 V AC - 10 % / + 15 %
Max. 250 mA (5 VA) Power Consumption
(24V DC)
Digital input
- Alarm acknowledge and test alarm
- Alarm relay /fault relay
Potential-free contact
40 V AC/DC, 0.5 A, change-over contact (SPDT)
Critical relay: Normally Closed (SIL II compliant), Warning relay: Normally
Open
Analoge output signal
Modbus Physical
Enclosure rate
Humidity range
Burning behaviour
Housing colour
UL 94 V2
Black
Dimensions (W x H x D in mm) 94 x 130 x 57
Installation Wall mounting
Cable entry
Wire connection:
Power supply, Modbus
Analog output, Digital input
Sensor head
Sensor information
Temperature range
Proportional, overload and short-circuit proof, load ≤ 500 Ohm
Measuring range: 0-10 V / 2-10V /0-20mA / 4-20mA
5 V DC, 250 mA max. overload, short-circuit and reverse-polarity protected
IP 65
15 - 90 % RH not-condensing
2 x M12 / 3 x M20
Screw-type terminals 0.25 to 2.5 mm
Screw-type terminals 0.25 to 1.3 mm
3-pin plug connector
DGS-IR (CO
2
)
-35 to +40°C
2
2
DGS-SC (HFC)
-30 to +50°C
DGS-PE (Propane)
-30 to +50°C
Response time T90
Recovery time, T0
Default alarm threshold
Compliance
<120s
90s
Maximum calibration interval 60 months
Measuring range 0-20,000ppm
5,000ppm
<40s
180s
12 months
20-2,000ppm
500ppm
<10s
120s
6 months
0-5,000ppm
800ppm
IEC61010-1 ANSI/UL CAN/CSA-C22.2 No61010-1 RoHS
B&L - Buzzer and Light
(option by product selection)
Ligt (LED)
Buzzer
Red / yellow /green (alarm - fault - operation - service)
>85 dB (A) (0.1 distance ) 2300 Hz
Ordering
DGS Sensors
Product Description
DGS-SC HFC gr. 1*
DGS-SC HFC gr. 2*
DGS-SC HFC gr. 3*
DGS-PE Propane
DGS-IR-CO2
DGS-IR-CO2 5 m
DGS-IR 2 * CO2 - 5 m
Code no.
080Z2803
080Z2804
080Z2805
080Z2806
080Z2800
080Z2801
080Z2802
Spares and accessories
Product Description
Spare sensor HFC gr.1*
Spare sensor HFC gr.2*
Spare sensor HFC gr.3*
Spare sensor Propane
Spare sensor CO2
Spare sensor CO2 - 5 m
Hand Held Service Tool
Spare
Spare
Spare
Spare
Spare
Spare
Accessory
Code no.
080Z2815
080Z2816
080Z2817
080Z2818
080Z2813
080Z2814
080Z2820
DGS-SC HFC gr.1* + B&L
DGS-SC HFC gr.2* + B&L
DGS-SC HFC gr.3* + B&L
DGS-PE Propane + B&L
DGS-IR CO2 + B&L
DGS-IR-CO2 5 m + B&L
080Z2809
080Z2810
080Z2811
080Z2812
080Z2807
080Z2808
*HFC gr.1:: R1234ze, R454c, R1234yf , R454a, R452A, R454b, R513a
HFC gr.2: R407F, R416a, R417a, R407A, R422a, R427a, R449A, R437a, R134A , R438a, R422D
HFC gr.3: R448A, R125, R404A, R32, R507A, R434a, R410A, R452b, R407C , R143b
Bold = calibration gas
Strobe & Horn
Splash guard
Duct set
Calibraton adaptor for SC2
Remote kit
Power Supply AK-PS075
Accessory
Accessory
Accessory
Accessory
Accessory
Accessory
080Z2819
148H6226
148H6236
148H6232
148H6238
080Z0053
Note: DGS is also available for alternative refrigerant gases on request. Please contact your local Danfoss Sales Office for details
2 RD8CN202 © Danfoss A/S (ADAP-KOOL®.), 2018-12
advertisement