Advertisement
Advertisement
Data sheet FHV regulating valve Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems Application FHV-A FHV-R FHV control valves are ideally suited to the temperature control of individual under-floor heated rooms and for systems using floor-heating in conjunction with radiators. Danfoss offers the following versions: - the FHV-R provides temperature control of underfloor heating circuits, using a return temperature limiting valve fitted with a type FJVR sensor element - the FHV-A enables floor temperature control via a pre-settable thermostatic valve fitted with a type RA 2000 sensor element Ordering and technical data Note: If using the FHV-A for room temperature control, the flow temperature should not be permitted to exceed the maximum recommended by the floor heating supplier. When the FHV-R is used for controlling floor heating, the heated floor area should not be greater than 10 m2. FHV control valves are flexible to use and can be simply and easily installed in the floor heating circuit. With the FHV-A, its integral pre-setting simplifies hydraulic balancing of the system. Connections to the 3/4" external thread are made with Danfoss compression connectors. FHV-R. Set includes wall enclosure box, cover and valve (return temperature limiter). An FJVR sensor element is required for controlling the return temperature. Type FHV-R FHV-R FJVR FJVR Description Valve with air vent & bleed key Valve with air vent, bleed key & drain hose Return temp. limiter sensor. Setting range 10 -50 °C Return temp. limiter sensor. Setting range 10 -80 °C Connection kvs (m3/h) G 3/4" A 0.88 G 3/4" A 0.88 Code no. 003L100000 003L100300 003L104000 003L107000 FHV-A. Set includes wall enclosure box, cover and pre-settable valve. A type RA2000 sensor element is required for controlling the room temperature. Type FHV-A FHV-A RA2010 RA2070 Description Valve with air vent & bleed key Valve with air vent, bleed key & drain hose Room temperature sensor. Setting range 5-26 °C Room temperature sensor. Setting range 5-22 °C Compression fittings PEX 15x2.5 mm PEX 16x2.2 mm PEX 18x2.5 mm PEX 20x2.5 mm Max. operating pressure Max. differential pressure Test pressure Max. flow temperature DKCD 6 bar 0,6 bar 10 bar 90 °C Code no. 013G414700 013G416300 013G415900 013G416100 Connection kvs (m3/h) G 3/4" A 0.04-0.79 G 3/4" A 0.04-0.79 Compression fittings ALUPEX 14x2 mm ALUPEX 16x2 mm ALUPEX 18x2 mm ALUPEX 20x2 mm Code no. 003L100100 003L100400 013G201000 013G207000 Code no. 013G418400 013G418600 013G418800 013G419000 Spare parts Gland seal for FHV-A Gland seal for FHV-R Code no. 013G029000 013U007000 Accessories Mounting tool/installation aid with integral spirit level Bleed key Anti theft plugs for RA2000 sensors Threaded range limiting pins for RA2000 sensors Toolkit, comprising allen key for RA2000 sensors Round front cover for FHV-R/A Square frontcover for FHV-R/A Extension piece for RA sensors Extension piece for FJVR sensors Code no. 003L133800 087N684900 013G123200 013G123700 013G123600 003L1050 003L105x 003L1035 003L1036 VD.31.A2.02 © Danfoss 09/2002 (50 pcs) (30 pcs) 17,9 mm 17,9 mm 1 Data sheet Regulating Valve, type FHV Systemlayouts Floor heating system; heating circuit with FHV-A in flow Floor temperature control, mixed system; heating circuit with FHV-R in return Danfoss pre-settable valve bodies incorporate easy setting adjustment rings with clearly engraved setting markers scaled from 1 - 7 and N. Setting values can be set quickly and precisely, without the need for tools, as follows: - Remove protective cap or sensor element - Lift setting ring - Turn anti-clockwise to the desired engraved setting value - Allow setting ring to spring back into position The preset level can be selected in 0.5 increments between 1 and 7 (see chart on page 3 for flow rates). At setting N the valve is fully open (flushing option). Pre-setting FHV-A Construction é é ê 1. 2. 3. 4. 5. 6. 7. 8. FHV-A Pressure pin Gland seal O-ring seal Return spring Valve cone Valve body Connections, G ¾A Air vent FHV-R Materialls in contact with water Setting cylinder PPS Spindle Ms, resistant against de-zincification O-ring EPDM Valve cone NBR Pressure pin, valve spring Chrome-plated steel ê 1. 2. 3. 4. 5. 6. Pressure pin Gland seal Valve cone Valve body Connection, G ¾A Air vent Connection: 3/4" external thread for compression fittings. Valve body, other metal parts Ms 58 2 VD.31.A2.02 © Danfoss 09/2002 DHCD Data sheet Regulating Valve, type FHV Capacities [mwg] Capacity with RA 2000 sensor at a P-band between 0.5 K and 2 K. [mwg] Capacity with FJVR regulator DKCD VD.31.A2.02 © Danfoss 09/2002 3 Data sheet Regulating Valve, type FHV Installation 152 mm 6" 1 2 3 FHV valves are equally suitable for installation in solid or partition walls. To assist in the fitting of FHV control valves, we offer a compact customised valve enclosure wall box that can be fitted and fastened easily into a shallow recess in any type of wall. All connections are made within the enclosure. The Danfoss sensor is simply plugged on. An optional installation aid, incorporating a spirit level, is available to make assembly extra easy and reliable. Code no. 003L1338 Ø178 Ø142 Dimensions Valve type L (mm) D (mm) FHV-A 31 58 FHV-R 31 58 4 VD.31.A2.02 © Danfoss 09/2002 DHCD ">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement