Samlexpower OC48-40 Specification
광고
광고
P O W E R C O N V E R S I O N P R O D U C T S
Omnicharge Programmable Batterycharger
FEATURES
• m o d e S w ti c h t e quiet operation c h n o l o g y
• Three full current outputs
• Industrial design f o r h i g h e f if c i e n c y , il g h t w e i g h t a n d
• Universal power factor corrected auto ranging AC input
• Parallel capability up to 6 units
• Protected against battery failure, high temperature, overload, short circuit, low input voltage and reverse polarity
• Multistage intelligent charging programs
• Programmable charging programs up to 8 stages
• Remote on/off capability, by Universal Remote Control or
Basic Remote Control (option)
• Temperature sensor included
• Easy to access connection bay for installing AC-DC and control wiring
• CE certified
• European product
• 2 year warranty
40 AMP
TECHNICAL SPECIFICATIONS
MODEL
AC Input Voltage
Full Load Power Consumption
AC Input Current (230V)
Total DC Output current 1) 4)
Nominal DC output voltage 1)
Number of full Current Outputs
Charge Characteristic 2)
Standard Absorption Voltage 2)
Standard Float Voltage 2)
Standard Equalize Voltage 2)
Supported Battery Types 2)
Recommended Battery Capacity 3)
DC Current Draw (charger off)
Operating Temp. Range 4)
Storage Temp. Range
Cooling
SAMLEXLink enabled
Protections Against
Indications
DC Output Connections
AC Input Connections
Enclosure Body size (HxWxD)
Total Weight
Protection Class
Standards
OC48-40
180-260Vac
2750VA
12A
40A
48Vdc
3 (internally isolated)
IUoUoP, intelligent 4-stage, temperature compensated
57,6Vdc
54,0Vdc
63,2Vdc
Flooded / GEL / AGM / LiFePO4 / Custom
80-400Ah
< 0,1mA
-10°C…+55°C (humidity max. 90% non condensing)
-20°C…+70°C (humidity max. 90% non condensing)
Variable speed fan controlled by temperature and load
Yes
Low AC voltage, output short circuit, high temperature, battery overcharging and reverse polarity (fuse)
Power On, Output Current Bar, State of Charge Bar, Error
4x M8 bolts
Screw terminals
370x271x132mm
6,2 Kgs
IP21 (mounted in upright position)
EMC : EN55016-2-1(/A1), EN55016-2- 3(/A1),
EN 61000-4-2(3/4/5/6). Safety : EN60335-1, EN60335-2-29
1) Maximum output current tolerance is +/-5%. Maximum set point voltage deviations are +/-1%. All set point voltages are temperature
compensated when the battery temperature sensor is connected.
2) Value is programmable.
3 ) A l w a y s c o n s u tl b a t t e r y m a n u f a c t u r e r s s p e c i if c a it o n s f o r m a x i m u m a ll o w a b l e c h a r g e c u r r e n t .
4) At higher ambient temperatures (>40°C), maximum output current may be reduced automatically.
Technical subject to change without notification.
To view a full selection of Samlex product s visit our website at: www.samlex.com or www.samlex-solar.com