Konica Minolta DIMAGE SCAN MULTI 2 Hardware manual
Pubblicità
Pubblicità
Hardware Manual
Thank you for purchasing the Minolta Dimâge Scan Multi II. The Dimâge Scan Multi II is a multiple format film scanner capable of scanning medium format, 35mm, 16mm, and sleeved APS film. With the optional APS adapter, advanced photo system film in the cassette can also be scanned.
Your new scanner has extraordinary features, including:
• Medium-format film scanning capability. The included medium-format film holder uses antinewton glass and includes masks for 6x4.5, 6x6, 6x7, 6x9.
• 12-bit AD converter, so fine detail is captured with a dynamic range.
This manual has been designed to help you understand the operation of your scanner. To realize all the benefits of your scanner, please read this manual and the accompanying software manual thoroughly.
The instructions in this manual assume you have a working knowledge of the operating system for your computer
(Mac OS, Windows 95, or Windows NT) and its conventions. Familiarity with the mouse and standard operating system menus and commands is necessary before operating the Dimâge Scan Multi II software.
This manual does not instruct in the:
• basic use of personal computers.
• use of Window 95, Windows NT, or Mac OS.
• use of Adobe Photoshop, Paint Shop Pro, or Corel Draw.
Microsoft, Windows®, Windows 95®, and Windows NT® are registered trademarks of the Microsoft Corporation.
Macintosh™, Apple®, and Power Macintosh® are registered trademarks of Apple Computer, Inc.
Other corporate and product names are the trademarks and registered trademarks of their respective companies.
• Changes or modifications not approved by the party responsible for compliance could void the user’s authority to operate the equipment.
• This manual may not be copied in part or whole without prior written permission from Minolta Co., Ltd. ©1998
Minolta Co., Ltd.
• Every necessary caution has been taken to ensure the accuracy of this instruction manual. Please contact us if you have any questions, find any errors, or notice missing information.
• Minolta is not responsible for loss, damage, or other results occurring during the operation of this product.
This mark certifies that this product meets the requirements of the EU (European Union) concerning interference causing equipment regulations. CE stands for Conformité Européenne.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Do not remove the ferrite cores from the SCSI cable.
This Class B digital apparatus complies with Canadian ICES-0003.
Cet appareil numérique de la classe B est conforme à la norm NMB-003 du Canada.
Tested by the Minolta Corporation
101 Williams Drive
Ramsey, New Jersey 07446
USA
FOR PROPER AND SAFE USE
Please read and understand each caution before using this product.
CAUTION
To avoid fire or electric shock:
• Only use the voltage specified for this unit.
• Do not expose this unit to liquids.
• Do not insert metal objects into this unit.
• Do not touch the cord or plug if your hands are wet.
• Unplug this unit when it is not in use.
Improper use of the power cord may result in fire or electric shock.
• Insert the plug securely into an electrical outlet.
• Do not pull on the cord. Grasp the plug when removing the power cord from an outlet.
• Do not scratch, twist, modify, heat, or place a heavy object on the power cord.
• Do not connect the ground to a gas pipe, telephone ground, or a water pipe.
Improper grounding can result in electric shock.
This product must have sufficient ventilation while in use. Blocked ventilation ducts may cause the unit to overheat, increasing the risk of fire.
• Do not use or store this product in dusty or very humid areas.
If there is smoke, a strange smell, or any other unusual conditions, shut down and unplug the unit, then contact a Minolta Service Facility.
Do not attempt to disassemble this product. It contains high-voltage circuits. Take the product to a Minolta Service facility for repairs.
Unexpected damage may occur if this unit is left unattended near young children.
1
TABLE OF CONTENTS
BEFORE YOU BEGIN
NAMES OF PARTS
CONNECTING TO THE COMPUTER
GETTING STARTED
LOADING 35MM FILM HOLDERS
LOADING THE MEDIUM FORMAT FILM HOLDER MH-M1
INSERTING THE HOLDER INTO THE SCANNER......................................................23
APS ADAPTER AD-100 (SOLD SEPARATELY)...........................................................24
CHANGING THE FLUORESCENT LAMP....................................................................28
IMPORTANT: BEFORE TRANSPORTING THE SCANNER ........................................30
2
3
PACKAGE CONTENTS
BEFORE YOU BEGIN
CHECK THIS PACKING LIST BEFORE YOU BEGIN. IF SOME PARTS ARE
MISSING, CONTACT YOUR DEALER OR A MINOLTA SERVICE FACILITY.
• Minolta Dimâge Scan Multi II scanner
• 35mm Film Holder FH-M1
• 35mm Slide Mount Holder SH-M1
• Medium Format Film Holder MH-M1
• Film Masks:
6 x 4.5 Medium Format Film Mask
6 x 6 Medium Format Film Mask
6 x 7 Medium Format Film Mask
6 x 8 Medium Format Film Mask
6 x 9 Medium Format Film Mask
APS Sleeve Film Mask
16mm Film Mask
• Power Cord PW-M2
• SCSI Cable SC-11
• Dimâge Scan Multi II CD-ROM v1.0
• Instruction Manuals (1 software, 1 hardware)
• Warranty and Software Registration card
4
SYSTEM REQUIREMENTS
MACINTOSH
CPU: Power PC, Power Macintosh G3, Blue & White Power Macintosh G3 and Power Macintosh G4 (Except for 68 K
Macintosh and Mac OS compatible unit). Power Macintosh G4 is recommended when loading with 16 bit and using the
Digital ROC/GEM functions.
Operation System:
Memory:
Hard Disk Space:
Monitor:
Mac OS 7.5.3 to 9.0.4
A minimum of 32 MB (megabytes) application RAM in addition to the requirements for the
Mac OS.
256 MB or more when loading with 16 bit and using the Digital ROC/GEM functions.
About 600 MB or more of available hard disk space.
About 2 GB or more of available hard disk space when loading with 16 bit and using the
Digital ROC/GEM functions. (About 3 GB or more is recommended.)
Minimum 13 (640 x 480) inch monitor capable of displaying at least 32,000 Colors.
19 inch(1024 x 768) or larger is recommended.
Necessary (when installing the software.) CD-ROM Drive:
Recommended SCSI Board:
With a Power Macintosh and Power Macintosh G3
The standard built-in SCSI board
Connecting to the extension board inserted into the PCI bus/NuBus is not available.)
With a Blue & White Power Macintosh G3*, Power Macintosh G4
Adaptec PowerDomain 2940UW/U2W, PowerDomain 2930U, SCSI Card 2906, and AVA-
2903B
* Some models in the Blue & White Power Macintosh G3 series use the Ultra2 Wide SCSI board as the standard built-in SCSI board, however, connecting the Dimage Scan Multi II to the standard built-in SCSI board is not recommended. The connecting capacity may be limited and the full capabilities of the PC may not be usable due to the specifications of the standard built-in SCSI board.
When using the model which has the standard built-in SCSI board, insert the recommended SCSI board as described above in the open slot without detaching the standard built-in SCSI board and then connect the Dimage Scan Multi II to the SCSI connctor on the inserted SCSI board.
Other: Adobe PhotoShop Ver. 4.0.1, Ver. 5.0.2, Ver. 5.5 and Adobe Photoshop 5.0 LE have been fully tested for use with the plug-in software.
MACINTOSH
CPU:
Orerating System:
Memory:
IBM PC/AT compatible with an Intel Pentium processor 90 MHz or above.
• Support cannot be provided for custom or home built machines.
Pentium III Processor is recommended when loading with 16 bit or using the Digital
ROC/GEM functions.
Windows®95 (inc. OSR2), Windows®98 (inc. Second Edition), Windows®2000
Professional, Windows®NT 4.0
A minimum of 32 MB (megabytes) of RAM.
A minimum of 512 MB when loading with 16 bit and using the Digital ROC/GEM functions.
Hard Disk Space: About 600 MB or more of available hard disk space.
About 2 GB or more of available hard disk space when loading with 16 bit and using the
Digital ROC/GEM functions. (About 3 GB or more is recommended.)
Monitor: Minimum VGA (640 x 480) monitor capable of displaying High Color (16 bit) is required.
XGA (1024 x 768) or larger is recommended.
Necessary (when installing the software.) CD-ROM Drive:
Recommended SCSI Board:
Adaptec AHA-1510B, AHA-1520B, AHA-1540CP, AHA-2910B, AHA-2910C, AHA-2920C,
AHA-2940, AHA-2940U/W/AU/UW/U2W, SCSI Card 19160/29160/29160N, AVA-
2902E/2903B/2906
Other: Photoshop Ver. 3.0.5, Ver.4.0.1, Ver. 5.0.2, Ver. 5.5, Photoshop 5.0 LE, Paint Shop Pro Ver.
6, Corel PHOTO-PAINT Ver. 9* have been fully tested for use with the TWAIN driver software.
*Corel Scan is not recommended.
5
FRONT
NAMES OF PARTS
Fluorescent lamp unit cover
Connector cover
Indicator lamp
Eject button
Power lamp
Power switch
Film-slot door
Accessory panel
BACK
AC socket
SCSI ID switch Centronics
Terminator dip switch D-sub-25 port
IMPORTANT: LOCKING PIN INFORMATION
UNLOCK THE OPTICS BEFORE
USING THE SCANNER FOR THE
FIRST TIME.
The optics inside the scanner have been parked and locked before shipment for their protection.
Before using the scanner for the first time, unlock the locking pin.
• Gently turn the scanner up-side down. Using a flat-head screwdriver, turn the locking pin counterclockwise until it pops up.
7
SETTING THE SCSI ID
The Dimâge Scan Multi II’s SCSI ID is factory preset to 5. If 5 is not being used by another operating SCSI device in the SCSI chain, it is not necessary to change the SCSI ID.
A SCSI ID is a unique address you assign to each SCSI device connected to your computer. The SCSI ID range of your computer is from 0 to 7, however some IDs are already occupied by your computer.
IBM PC/AT:
Macintosh:
Occupied SCSI ID
7 (SCSI host adapter)
0 (internal hard drive)*
3 (internal CD-ROM drive)**
7 (system)
* IDE Macintosh systems do not use SCSI ID 0 for the hard drive.
** Macintosh systems with a dual bus have SCSI ID 3 available on the external bus.
TURN OFF THE COMPUTER AND ALL THE SCSI DEVICES
BEFORE CHANGING SCSI IDS, CONNECTING SCSI
CABLES, OR DISCONNECTING SCSI CABLES.
TO CHANGE THE SCSI ID:
1. Turn off the computer and all connected SCSI devices.
2. Determine which SCSI IDs are not being used.
3. Change the SCSI ID using the upper or lower SCSI buttons.
Press the upper button to select a smaller SCSI number.
The current SCSI ID number.
Press the lower button to select a higher SCSI number.
8
CONNECTING TO THE COMPUTER
IF THE SCANNER IS THE ONLY OR LAST DEVICE IN THE CHAIN…
TURN OFF THE COMPUTER AND ALL THE SCSI DEVICES
BEFORE CHANGING SCSI IDS, CONNECTING SCSI
CABLES, OR DISCONNECTING SCSI CABLES.
One D-sub-25 to Centronics 50 cable is included with your scanner. Please see your dealer if you require a different cable.
1. Connect one end of the SCSI cable to either
SCSI port on the back of the scanner.
• Either SCSI port can be used, there is no dedicated in or out port.
2. Connect the other end of the SCSI cable to the
SCSI port on the computer or on the last SCSI device in the chain.
3. Flip the dip switch marked 1 up to turn the terminator on.
• Dip switches 2 through 4 are inactive. Their position will not affect the scanner operation.
9 Continued on following page.
CONNECTING TO THE COMPUTER
4. Plug the power cord into the scanner’s AC socket.
5. Plug the other end of the power cord into a grounded outlet.
10
IF THE SCANNER IS INSIDE THE CHAIN…
TURN OFF THE COMPUTER AND ALL THE SCSI DEVICES
BEFORE CHANGING SCSI IDS, CONNECTING SCSI
CABLES, OR DISCONNECTING SCSI CABLES.
One D-sub-25 to Centronics 50 cable is included with your scanner. Please see your dealer if you require additional cables.
The following is an example of one possible SCSI chain configuration.
Computer
SCSI Device 1
Scanner
SCSI Device 2
Cable “A” Cable “B”
1.
Connect one end of the SCSI cable A into either SCSI port on the back of the scanner.
• Either SCSI port can be used, there is no dedicated in or out port.
2. Plug the other end of SCSI cable A into SCSI device 1.
11 Continued on following page.
CONNECTING TO THE COMPUTER
3. Connect one end of SCSI cable B into the remaining SCSI port on the back of the scanner.
4. Connect the other end of SCSI cable B into the next device in the chain.
5. Flip the dip switch marked 1 down to turn the terminator off.
• Dip switches 2 through 4 are inactive. Their position will not affect the scanner operation.
6. Plug the power cord into the scanner’s AC socket.
12
7. Plug the other end of the power cord into a grounded outlet.
The total length of should not e
(20 ft.) for most systems
.
13
GETTING STARTED
FILM EMULSION
The emulsion side of the film is the side coated with the photographic material. The base side of the film has no photographic material and its surface is smooth and shiny. The emulsion side of slide film has raised areas at subject contrast. The emulsion side of negative film is dull compared to the base side. It is easiest to determine the emulsion side when viewing the film at an angle.
Light Viewing angle
FILM EMULSION
Slightly dull or raised surface
FILM BASE
Smooth, shiny surface
The frame numbers and text are backward when the film’s emulsion side is up.
HANDLING CARE
• Do not pull the film holder out of the scanner until the holder is properly ejected and the green indicator light is off.
• Do not move the scanner or touch the film holder while the transport motor is engaged (such as while scanning).
• Place the scanner on a stable surface.
14
LOADING 35MM FILM HOLDERS
SLIDE MOUNT HOLDER SH-M1
• The slide mount holder can hold up to 4 mounted slides (35mm or APS).
• Slide mounts must be thicker than 1mm and thinner than 2mm to fit properly into the holder.
• Results of scanning glass-mounted slides can be unpredictable.
• Blow dust off the slide before placing it into the film holder.
1. Position the slide mount holder so the white arrow is on the top-left side, then open the slide mount.
• Open the slide holder by pushing up on the two tabs from underneath.
2. Place the slides within the indentations, making sure they lie flat.
• Insert the slides emulsion side down.
3. Press the cover firmly closed until it clicks.
15
35MM FILM HOLDER FH-M1
Use the FH-M1 for 35mm negatives and unmounted 35mm slide film.
• The 35mm Film Holder FH-M1 can hold film strips up to 6 frames long.
• Blow dust off the film before placing it into the film holder.
1. Position the film holder so the white arrow is on the top-left side, then open the slide mount.
• Open the slide holder by pushing up on the two tabs from underneath.
2, Place the film in the film holder emulsion side down.
3. Align the frames within the scanning windows.
16
17
4. Press the cover firmly closed until it clicks.
LOADING THE MEDIUM FORMAT HOLDER MH-M1
USING THE MEDIUM FORMAT HOLDER MH-M1
Use the MH-M1 for 120/220 film frames in 6x4.5, 6x6, 6x7, and 6x9 formats. The MH-M1 should also be used for sleeved APS film, 16mm film, and TEM* film. Use the appropriate film mask for each film format. The glass in the
Medium Format Film Holder MH-M1 has been treated to prevent the appearance of Newton’s rings (coloured rings) when scanning.
• Handle the Medium Format Film Holder MH-M1 with care. Protect the glass from impact, shock, and scratches.
• Touching the glass in the film holder may cause damage to the antinewton treatment.
• Blow away any dust from the film holder before inserting the film. If the film holder is dirty, first blow away any dust or debris, then moisten a lens cleaning tissue with lens cleaning fluid and gently wipe the surface.
* Transmission Electron Microscope
MEDIUM FORMAT AND TEM FILM
1. Press on the lever marked
“PUSH”, then lift open the holder.
Align the slot in the mask with the rail on the film holder.
2. Select the appropriate mask and place it in the film holder using the guides.
• The cut corner on the mask should be on the bottom-left side.
• Choose the appropriate size mask for
TEM film.
Align the holes in the mask with the pins on the film holder.
18
3. Place the film in the film holder.
• Secure the film by placing it flush against the rail on the film holder.
• Place the film emulsion side down
(p 14).
Secure the film by placing it flush against the rail on the film holder.
4. Press the cover firmly closed until it clicks.
Always use a proper ly fitting mask with the medium f ormat film holder. If no mask or a mask that is too large is used, refr .
degrade image quality
19
16mm AND APS SLEEVE FILM
1. Press on the lever marked
“PUSH”, then lift open the holder.
Align the slot in the mask with the rail on the film holder.
2. Place the APS Sleeve mask or
16mm mask on the film holder.
• The film guides on the mask should be on the right side.
Align the holes in the mask with the pins on the film holder.
20
Make sure the film lies flat between the film guides.
3. Place the film in the mask using the film guides.
• Place the film emulsion side down
(p 14).
Make sure the film lies flat between the film guides.
4. Align the desired frame within the scanning window.
5. Press the cover firmly closed until it clicks.
Always use a proper ly fitting mask with the medium f ormat film holder. If no mask or a is used, refr will degr ade image quality.
21
ROTATING THE FRAME
The image area of the Medium Format Holder MH-M1 can rotate 10 degrees in either direction to compensate for a tilted image composition. By rotating the frame before scanning, the need to rotate the scanned image, thus resampling the pixels, is eliminated.
1. Turn the holding screw counter clockwise to loosen it.
2. Rotate the carrier as desired.
• Use the angle scale on the holder for reference.
• With larger film formats, the corners of the frame may not fit in the scanning area when the carrier is rotated.
3. Turn the holding screw clockwise to secure it.
22
EJECTING
INSERTING THE HOLDER INTO THE SCANNER
1. Press the power switch to turn the scanner on. Turn on your computer, then launch the
Dimâge Scan Multi II software.
• The green indicator lamp will blink slowly while the scanner is setting up.
2. Insert the holder into the scanner in the direction indicated by the white arrow on top of the holder.
• Do not insert the holder at an angle.
3. Gently push the holder into the scanner until the raised insertion mark is aligned with the film-slot door.
• The film holder will be automatically guided in past the mark.
• If the holder is not loaded correctly, then eject and reinsert it.
1. Press the eject button on the front of the scanner.
• The holder will automatically eject partway, then stop.
2. Remove the holder.
• Wait for the Indicator lamp to turn off before removing the holder.
• The holder should pull out easily.
23
APS ADAPTER AD-100 (SOLD SEPARATELY)
• The APS Adapter AD-100 (optional accessory) is required to scan APS film in the cassette with the Dimâge Scan Multi II.
Only processed film with the VEI set to can be inserted into the APS Adapter AD-100.
APS ADAPTER – NAMES OF PARTS
Film-chamber release
Film-chamber door
24
Scanner contacts*
* Do not touch
LOADING THE CASSETTE
1. Slide the film-chamber release as shown.
• The film chamber door will open.
2. Insert the film cassette into the film chamber with the VEI on top.
• Only load cassettes displaying the mark.
3. Close the film-chamber door.
• The film-chamber release will return to its start position when the door is closed properly.
25
INSERTING THE ADAPTER
1. Press the power switch to turn the scanner on. Turn on your computer, then launch the
Dimâge Scan Multi II software.
• The green indicator lamp will blink slowly while the scanner is setting up.
2. Pull the accessory panel on the scanner straight out, then open it all the way pushing it until it clicks.
• Do not force the accessory panel.
• Do not open the accessory panel during the set-up process. Wait until set-up is complete and the indicator lamp is off.
3. Insert the holder into the scanner in the direction indicated by the white arrow on top of the adapter.
• Do not insert the adapter at an angle.
4. Gently push the adapter into the scanner until the raised insertion mark is aligned with the film-slot door.
• The adapter will be automatically guided in past the mark.
• If the adapter is not loaded correctly, then eject and reinsert it.
26
EJECTING THE ADAPTER
1. Press the eject button on the front of the scanner.
• The adapter will automatically eject partway, then stop.
2. Remove the adapter.
• Wait for the Indicator lamp to turn off before removing the adapter.
• The adapter should pull out easily.
• When the Eject button on the front of the scanner is used, the film will rewind into the cassette before the adapter is ejected, regardless of the software Preference settings. Please refer to the Preferences section in the software manual.
• If a film transport error occurs, do not use that cassette in the adapter. Contact a Minolta
Service Facility.
• Minolta is not responsible for damage to the cassette.
• With some camera models the images will appear up-side-down. Use the Rotate All
Frames 180˚ option in the Preferences. Please refer to the Preferences section in the software manual.
27
CHANGING THE FLUORESCENT LAMP
When the indicator light is red and blinks rapidly, check to see of the fluorescent lamp is operational. Replace the fluorescent lamp when it burns out. See your dealer to purchase a replacement lamp unit.
CAUTION:
Turn off the scanner and allow the unit to cool for 10 minutes before removing the fluorescent lamp.
1. Remove the fluorescent lamp unit cover.
2. Pull up the locking bar.
3. Press on the release tab on the plug and disconnect the old lamp.
28
29
4. Connect the new lamp.
• Snap the connectors together until they click.
5. Place the lamp unit in the scanner by aligning the raised edge of the lamp unit 1 with the rectangular notch 2 on the scanner.
• The arrows on the lamp and scanner should be lined up.
• The lamp unit will not slide from side to side if it is inserted correctly.
6. Hold the lamp unit in place and replace the locking bar.
7. Replace the fluorescent lamp unit cover.
IMPORTANT: BEFORE TRANSPORTING THE SCANNER
Before transporting the scanner the optics must be parked and locked into place to prevent damage.
1. With the Dimâge Scan Multi II software active (utility, TWAIN driver, or plug-in):
Windows: press Ctrl + Shift + L.
Macintosh: press Command + Shift + L.
2. The message informing you the optics will be moved will appear. Click on OK.
3. After the optics have been moved, a message will appear asking you to turn the scanner off. Click on OK.
• The utility software will quit.
4. Turn off the computer.
5. Turn off the scanner and other SCSI devices.
6. Gently turn the scanner up-side down. Using a flat-head screwdriver, push down and turn the locking pin clockwise until it locks down.
• Once the optics have been moved to the locking position through the software, the scanner must perform the set-up operation to return to normal. The scanner automatically performs set-up when it is first turned on. Set-up can also be initiated by pressing the following keys simultaneously while the software is active:
Windows95/NT: Control + Shift + i
Macintosh: Command + Shift + i
30
TROUBLESHOOTING
Symptom
The computer will not start after connecting the scanner.
Cause/Action
Check that all the SCSI cables are secure.
Check that two SCSI devices are not sharing the same address.
Reference
Page 8
The computer does not recognize the scanner.
Was the scanner turned on before the computer was turned on?
Check that all the SCSI cables are secure.
Windows 95/NT: Check that the SCSI device driver been installed correctly.
1. Select Start ‘ Settings ‘ Control Panel.
• The Control Panel window will appear.
2. Double-click on the System Icon, then click on the Device Manager tab.
3.Click on the plus (+) next to
“SCSI controllers”.
• A sub-menu of SCSI controllers should appear.
4. Confirm the appropriate SCSI Controller for your board is listed in the sub-menu.
The scanner does not pull in the film holder when loading
Eject, then reinsert the holder.
The film holder must be inserted to the marks for it to be engaged by the scanner’s motor
The scanned image is very green or blownout white when using the Medium-format holder.
The mask does not fit the image properly. Be sure to use a proper fitting mask that is not too big for the image. There should be no uncovered space between the film and the mask.
Pages 18 -21.
The indicator lamp glows red.
If using a film holder:
The accessory panel is open. Close the accessory panel.
If using the APS adapter:
The accessory panel is not fully open.
Open it all the way and push it until it clicks.
31 Continued on following page.
Page 26.
TROUBLESHOOTING
Symptom
The indicator lamp is red and blinks rapidly or
The scanned image is black.
Cause/Action
1. Turn off the computer, then the scanner.
Check that the fluorescent lamp cover is closed.
2. Turn on the scanner. If the fluorescent lamp does not glow, replace the lamp.
3. If the cover was closed, the fluorescent lamp works, and the red lamp continues to blink rapidly, there is a hardware problem. Turn off and unplug the scanner, then call a Minolta Service Facility.
Reference
Page 28.
The scanned image colour is strange.
Check that there is no dust on the film or film holder.
Check that the colour palette (START –
SETTINGS – CONTROL PANEL – DISPLAY
– SETTINGS) is on High Colour (16 bit) or higher. Different or additional steps may be necessary depending on your graphics board.
Refer to your graphics board‘s documentation.
If using the Medium-format holder, be sure to use a proper fitting mask. If the holder is dirty, clean it as directed.
Reinitialize the scanner.
Windows 95/NT: Press Control, Shift, and i keys simultaneously.
Macintosh: Press Command, Shift, and i keys simultaneously.
Reinitializing while using the APS adapter:
1. Press the initialization key combination.
2. The adapter will eject automatically.
3. Initialization (set-up) will stop.
4. Remove the adapter.
5. Close the accessory panel.
• Initialization (set-up) will resume.
32
INDICATOR LAMP
The indicator lamp on the front of the scanner reveals the status of the scanner.
Off
Indicator Lamp Scanner Status
Set up is complete and there is no holder inserted in the scanner.
Green – blinking slowly
Green – blinking quickly
Green – glows steadily
Red – glows steadily
Red – blinks quickly
Scanner is busy:
• setting up (initializing).
• index scanning, prescanning, or scanning.
• autofocus, point AF, manual focus.
If using a film holder, the scanner is busy:
• loading the film holder.
• transporting the film holder.
• ejecting the film holder.
If using the APS Adapter, the scanner is busy:
• rewinding the film in the APS adapter.
• transporting the adapter.
There is a film holder in the scanner. The scanner is not busy.
There is a problem with the accessory panel.
If using a film holder:
The accessory panel is open. Close the accessory panel.
If using the APS adapter:
The accessory panel is not fully open.
Open it all the way and push it until it clicks.
The fluorescent lamp unit cover is not fully closed.
or
The fluorescent lamp is burnt out.
or
There is a hardware malfunction. Contact a
Minolta Service facility.
33
Type:
Usable Film:
Scanning Dimensions:
Optical Input Resolution:
A/D Conversion:
Image Sensor:
Continuous Scan Max.:
TECHNICAL DETAILS
Film transport, fixed sensor, 1 pass scan film scanner
Medium format film (6x4.5, 6x6, 6x7, 6x8, 6x9) – positive/negative, colour/B&W;
35mm film - positive/negative, colour/B&W;
Transmission Electron Microscope film – (5.9 x 8.2cm) positive/negative, colour/B&W;
16mm film – positive/negative, colour/B&W;
APS sleeve film – positive/negative, colour/B&W
APS Casette (with optional adapter) – positive/negative, colour;
35mm
6 x 4.5
6 x 6
6 x 7
6 x 8
6 x 9
TEM
APS
16mm
24.20 x 36.30mm
56.16 x 41.76mm
56.16 x 56.16mm
56.16 x 64.80mm
56,16 x 78,08mm
56.16 x 83.52mm
56.16 x 82.00mm
17.28 x 29.95mm
13.00 x 19.50mm
2688 x 4032 pixels
2496 x 1856 pixels
2496 x 2496 pixels
2496 x 2880 pixels
2496 x 3472 pixels
2496 x 3712 pixels
2496 x 3712 pixels
1920 x 3328 pixels
2688 x 4032 pixels
2820dpi: 35mm, APS, and 16mm film
1128dpi: Medium format and TEM film
12-bit
RGB 3-line CCD (2700 pixels)
35mm Sleeved: 6 frames
35mm Mounted: 4 frames
APS Cassette (requires optional accessory): 40 frames
35mm Mounted with optional Slide Feeder: 50 frames
Interface:
SCSI Ports:
Light Source:
Power/Frequency:
SCSI-2
D-Sub 25 pin, Centronics 50
Hot cathode fluorescent lamp, 3 wavelength, user replaceable.
AC 100 – 240V, 50/60Hz
Dimensions:
Weight:
(w)200 x (d)410 x (h)124mm (7.9 x 16.1 x 4.9 in.)
Approximately 6kg (211.8 oz)
Specifications are based on the latest information available at the time of printing and are subject to change without notice.
34
CUSTOMER SERVICE
Please contact your dealer regarding installation, SCSI interface recommendations, or application compatibility. If your dealer is unable to help you, contact us toll free.
Technical Support
1-800-808-4888
Monday – Friday 8:30-5:00 (EST)
Minolta Corporation
101 Williams Dr.
Ramsey, NJ 07446
(201) 825-4000i
Please have the following information ready when calling Minolta Technical Support:
Make and model of your computer:
Available application RAM:
Operating system and version:
Other connected SCSI devices and their SCSI ID numbers:
DS Multi II software version number:
Symptoms:
Messages that appear on the screen when the problem occurs:
Frequency of occurrence:
To determine the version number of your driver software:
Place the pointer over the Status Bar in the Command window. The version number will be displayed in the status window.
35
A Minolta Austria Ges.m.b.H
Amalienstr. 59-61, A-1131 Wien, Österreich
Tel:01 87868 176
Fax:01 87868 153 http://www.minoltaeurope.com
B Minolta Belgium Branch
Prins Boudewijnlaan 1
B-2550 Kontich, België
Tel: 03 451 07 00
Fax: 03 458 50 48 http://www.minolta.be en http://www.minolta.nl
CAN Minolta Canada Inc., Head Office
369 Britannia Road East,
Mississauga, Ontario L4Z 2H5, Canada
Tel.0905 890 66 00
Fax0905 890 71 99 http://www.minolta.com
CH Minolta (Schweiz) AG
Riedstr. 6, CH-8953 Dietikon, Schweiz
Tel:157 57 11 (sFr 2.15/min)
Fax:01 741 33 12 http://www.minolta.ch
D Minolta Europe GmbH
Minoltaring 11,
D-30855 Langenhagen,
Deutschland
Reparatur/Repair
Senator-Helmken-Strasse 1,
D-28279 Bremen,
Deutschland
Hotline: Tel: 0221 5 60 60 31
Fax: 0221 5 60 60 40 http://www.minolta.de
DK Paul Westheimer A/S
Erhvervsvej 30, DK-2610 Rødovre, Danmark
Tel:44 85 34 00
Fax:44 85 34 01 http://www.minoltaeurope.com
E Videosonic S.A.
c/ Valportillo II, 8, Pol. Ind. de Alcobendas,
E-28108 Alcobendas/Madrid, Spain
Tel:91 4840077
Fax:91 4840079 http://www.minoltaeurope.com
F Minolta France S. A.
365, Route de Saint-Germain,
F-78420 Carrières-Sur-Seine, France
Tel:0130 86 62 37
Fax:0130 86 62 82 http://www.minolta.fr
FIN Minolta Finland Branch
Niittykatu 6, PL 37 SF-02201 Espoo, Finland
Tel:435 565 0
Fax:435 565 56 http://www.minolta.fi
GB Minolta (UK) LTD. Photographic Division
Precedent Drive,
Rooksley, Milton Keynes, MK13 8HF, England
Tel:01 908 208 349
Fax:01 908 208 334 http://www.minoltaeurope.com
I
IRL Photopak Sales
241 Western Industrial Estate, Naas Road,
Dublin 12, Ireland
Tel:01 45 66 400
Fax:01 45 00 452 http://www.minoltaeurope.com
Rossi & C. S.p.A.
Via Ticino 40,
I – 50019 Osmannoro Sesto Fiorentino (Fi),
Italy
Tel.:055 323141
Fax:055 32314252 http://www.minoltafoto.it
N Scandiafilm AS
Enebakkveien 304, N-1188 Oslo 11, Norge
Tel:022 28 00 00
Fax:022 28 17 42 http://www.minoltaeurope.com
NL Minolta Camera Benelux B.V.
Zonnebaan 39, Postbus 6000
3600 HA Maarssen, Nederland
Tel: 030 247 08 09
Fax: 030 247 08 88 http://www.minolta.nl
P Minolta Portugal Lda
Av. do Brasil 33-a, P-1700 Lisboa, Portugal
Tel:01793 00 16
Fax:01 793 10 64 http://www.minoltaeurope.com
S Minolta Svenska AB
P. O. Box 9058, Albygatan 114, S-17109 Solna,
Sverige
Tel:08 627 76 50
Fax:08 627 76 21 http://www.minoltaeurope.com
Sin Minolta Singapore (Pte) Limited
10 Teban Gardens Crescent, Singapore 2260
Tel:56 35 533
Fax:56 10 217 http://www.minolta.com
36
37
Scarica