- Entertainment & hobby
- Musical instruments
- Recording Equipment
- Clear-Com
- ProGrid PG8/PG16-AUDIO-FX
- User Guide
advertisement
PG16-FX and PG8-FX User Guide
PN: 399G091 Rev B 10/22/14
Document Reference
Clear-Com PG16-FX and PG8-FX User Guide
Part Number: 399G091 Revision: B
Legal Disclaimers
Copyright © 2014 HME Clear-Com Ltd.
All rights reserved.
Clear-Com and the Clear-Com logo are registered trademarks of HM Electronics, Inc.
The software described in this document is furnished under a license agreement and may be used only in accordance with the terms of the agreement.
The product described in this document is distributed under licenses restricting its use, copying, distribution, and decompilation/reverse engineering. No part of this document may be reproduced in any form by any means without prior written authorization of Clear-Com, an HME
Company.
Clear-Com Offices are located in California, USA; Cambridge, UK; Dubai, UAE; Montreal,
Canada; and Beijing, China. Specific addresses and contact information can be found on
Clear-Com’s corporate website: www.clearcom.com
Clear-Com Contacts
Americas and Asia-Pacific Headquarters
California, United States
Tel: +1.510.337.6600
Email: [email protected]
Europe, Middle East, and Africa Headquarters
Cambridge, United Kingdom
Tel: +44 1223 815000
Email: [email protected]
Canada Office
Quebec , Canada
Tel: +1 (450) 653-9669
China Office
Beijing Representative Office
Beijing, P.R.China
Tel: +8610 65811360 / 65815577
2 PG16-FX and PG8-FX User Guide
Contents
Operating and Storage Temperature ............................................................... 5
PG16-FX with Analogue Input- and Output Cards ......................................... 12
PG8-FX or PG16-FX with Dual Microphone .................................................. 12
3 PG16-FX and PG8-FX User Guide
Hardware Connection Example ..................................................................... 18
4 PG16-FX and PG8-FX User Guide
1 Important Safety Instructions
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
Only use attachments/accessories specified by the manufacturer.
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-cord supply or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Warning: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.
1.1 Operating and Storage Temperature
Operating temperature: -20
°
C …50
° C ≡ -4 °
F … 122
°
F; ensure proper ventilation
Storage temperature: -20
°
C …60
° C ≡ -4 °
F … 140
°
F
1.2 Eye Safety
This product is a Laser Class 1 product. It complies with IEC 60825-1, FDA 21 CFR 1040.10, and 1040.11.
5 PG16-FX and PG8-FX User Guide
1.3 Safety symbols
Familiarize yourself with the safety symbols in Figure 1: Safety symbols . These symbols are
displayed on the apparatus and warn you of the potential danger of electric shock if the system is used improperly.
Figure 1-1: Safety symbols
6 PG16-FX and PG8-FX User Guide
2 Device Description
Optocore TECHNOLOGY
Optocore™ is a technology platform for sending large amounts of audio, with very low latency around a fiber-based network. This transport (and management system) is of very high quality, suitable for concerts, recording studios, and broadcast applications. SANE™ is a spin-off technology that adapts this same technique to a smaller network
(Ethernet) and at a lower cost. The SANE connections are used to provide expansion units at any fiber node.
ProGrid interfaces use both Optocore and SANE technologies to provide a high quality low latency media transport system. ProGrid will interface with all other OEM products utilizing the Optocore technology, for example Yamaha,
DiGiCo and AVID.
12 in 1 - the PG16/PG8-FX is a network converter unit for OPTOCORE and SANE with the highest degree of flexibility with regards to the I/O configuration. Six different card types enable the complete customisation of the I/O card, whether for the conversion of analogue signals - 16 inputs, 16 outputs, 8 inputs and 8 outputs, dual microphone inputs with dual independent adjustable gains – to AES/EBU, 8 AES/EBU channels switchable to IN or
OUT in groups of four or a sample rate converter for AES/EBU input signals as required. The PG16/PG8-FX is designed for sample rates up to 192 kHz. Twelve different versions are available:
•
16 microphone inputs (PG16) resp. 8 microphone inputs (PG8)
•
16 line inputs (PG16) resp. 8 line inputs (PG8)
•
16 line outputs (PG16) resp. 8 line outputs (PG8)
•
8 microphone and 8 line inputs (only PG16)
•
8 microphone inputs and 8 line outputs (only PG16)
•
8 line inputs and 8 line outputs (only PG16)
•
8 microphone inputs with two independent preamps each (only PG16)
•
8 AES/EBU inputs (16 audio channels) with sample rate converters (only PG16)
•
8 AES/EBU channels (I/O switchable in groups of four) (only PG16)
•
4 AES/EBU inputs or outputs + 8 microphone inputs
•
4 AES/EBU inputs or outputs + 8 line inputs
•
4 AES/EBU inputs or outputs + 8 line outputs
Redundant fiber connections can be established using the two provided LC multimode or singlemode 2 GBit optical
LINK-interfaces. The dual redundant ring structure provides maximum safety in a network with an outstanding low latency. It facilitates the use of the advantages of fiber optical transmission in all sorts of temporary and permanent applications, especially when long distance connections and high-quality audio are required.
The PG16/PG8-FX and PG16/PG8-TP can be used together in a SANE CAT5 Network (64 audio channels +
Ethernet). Combinations of SANE and O (up to 1024 channels) can be done by PG16/PG8-FX and other Revolution
FX devices to exchange audio channels and Ethernet. All parameters on the converters can be controlled and monitored with the same software application as all other ProGrid devices, OPTOCORE CONTROL software. They allow for the distribution of various I/O channels at different locations throughout your digital ProGrid and/or SANE network.
The PG16/PG8-FX is especially designed for rack mounted applications and permanent installation. All cards are equipped with Euroblock / Phoenix connectors. These common installation interfaces provide a simple and costefficient connection with other audio equipment.
The PG16-FX with the dual microphone input card removes the problem where only one of the FOH or Monitor engineers can have full gain control of a single microphone input channel. Every microphone input incorporates two independent microphone preamps meaning both can be adjusted individually. Therefore, analogue split boxes with
7 PG16-FX and PG8-FX User Guide
two stage racks to give FOH and monitor engineers the freedom to adjust their mic preamps directly at their own console can be a thing of the past.
The PG16-FX with sample rate converters enables the connection of audio devices operating at different sample rates.
The PG16-FX with combination of an AES/EBU and analogue card allows using 8 AES/EBU channels switchable to inputs or outputs in groups of four, or using 4 AES/EBU channels and 8 analogue channels. The entire configuration can be done by the Optocore Control software.
The PG16/PG8-FX with analogue mic input, line input and line output cards allow customised I/O configuration per device. Two/one card slots can be equipped with different cards, so six combinations with 16 inputs, 16 outputs or 8 inputs and 8 outputs can be assembled for the PG16 according to the customer’s requirements.
The microphone inputs include a high quality microphone preamp, phantom power and selectable gains in 1 dB steps from -4 dB to +66 dB at a maximum input level of 22 dBu. The line inputs are equipped with selectable maximum channel levels of 27 dBu, 22 dBu, 18 dBu, 8 dBu and the line output with a selectable maximum channel level of 22 dBu, 18 dBu, 12 dBu, 8 dBu. The high quality preamps, A/D- and D/A converters make the PG16 units ideal for the incorporation into audio systems even if no ProGrid network is present. They provide a wide dynamic range with negligible distortion and extremely low noise.
The Word Clock IN and OUT connections enable the synchronisation of the units to an external source and are used to pass the word clock from one unit to the next. For stand-alone applications, the devices are equipped with an internal word clock.
The PG16/PG8-FX units can be operated and controlled via the ProGrid network with OPTOCORE CONTROL software without the need for any external data cable. For control in stand-alone applications, USB, RS232 or LAN ports on the front / rear panels can be used.
The FPGA (field programmable gate array) based concept of the internal logic circuitry allows updating of the firmware ensuring a continual state-of-the-art device. OPTOCORE CONTROL software provides all configuration and control tools including naming, gain setting, and phantom power activation for attached devices, storage and recall of configurations on the computer, off- and online operational modes, as well as real-time level display of the individual channels when in online mode.
The LEDs on the front panel of the PG16/PG8-FX units allow an instant overview regarding the status of each channel. They indicate if audio is present on a channel, if a user defined or peak level is reached and the activation of the phantom power per channel.
8 PG16-FX and PG8-FX User Guide
3 Card Types
Six types of cards with Euroblock / Phoenix connectors can be incorporated into the card slots
•
8 microphone inputs
•
8 line inputs
•
8 line outputs
•
8 microphone inputs with two independent preamps each
•
8 AES/EBU inputs with sample rate converters
•
8 AES/EBU channels switchable to inputs or outputs in groups of four
The PG16/PG8-FX is shipped preconfigured with I/O cards according to the order placed with Clear-Com.
9 PG16-FX and PG8-FX User Guide
4 Front Panel
4.1 PG16-FX
4.2 PG8-FX
Word Clock LED: Indicates the selected word clock source:
INT: Internal word clock BNC: External via BNC Input
AES: External via AES
Card and Signal Monitor for the 2 x 8 Channels (1 x 8 for PG8)
A and B Card in slot A and B:
AES IN: 16 channel sample rate conversion card
MIC IN: 8 channel microphone input card
DUAL: 16 channel microphone input card with 8 microphone inputs and two independent preamps each
PEAK
LEVEL
SIGNAL
LINE IN: 8 channel line input card
LINE OUT: 8 channel line output card
Red: Overflow, input level exceeds max. input level of 0dBFS
Yellow: Warning level, input level exceeds -10dBFS
Green: Signal present
≥ -60dBFS, brightness controlled
AUDIO LINK:
SL1:
SL2:
OL1:
OL2:
Communication is established via SANE 1 (rear panel)
Communication is established via SANE 2 (rear panel)
Communication is established via Optocore LINK 1 (rear panel)
Communication is established via Optocore LINK 2 (rear panel)
Master LED:
OPTO LED:
SANE LED:
Indicates the master unit
OPTOCORE communication is established
SANE communication is established
Device ID Display: Indicates the identification number of the device
10 PG16-FX and PG8-FX User Guide
HEALTH LED:
PWR 1 LED:
PWR 2 LED:
Green: Power supply is correctly working, temperature is below the limit
Power supply 1 is working correctly
Power supply 2 is working correctly
USB plug and LED: USB connection for remote control via PC
Green: Indicates data activity
RS232 plug: D-Sub-9 RS232 connection for remote control and update via PC
LAN LINK:
S1:
S2:
UP:
L1:
L2:
Ethernet communication is established via SANE 1 (rear panel)
Ethernet communication is established via SANE 2 (rear panel)
There is other device with physical Ethernet port enabled on the network
Ethernet communication is established via LAN 1 (rear panel)
Ethernet communication is established via LAN 2 (rear panel)
POWER / MUTE Mic Card Phantom Power / Output Card Mute
Sample rate LED: Yellow: 44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz
11 PG16-FX and PG8-FX User Guide
5 Rear Panel
5.1 PG16-FX with Analogue Input- and Output Cards
5.2 PG8-FX or PG16-FX with Dual Microphone
RS485/GPIO plug:
Word Clock IN:
D-Sub-9 RS485 AUXILIARY PORT for data transmission
BNC Word clock input allows synchronization of ProGrid devices to an external word clock source
BNC Word clock output for synchronization of external devices Word Clock OUT:
POWER 2: Mains input for power supply 2 (100 … 240 V)
Mains input for power supply 1 (100 … 240 V) POWER 1:
Labels: Information about card types in the slots
GROUP: Cards with Euroblock / Phoenix connectors (8 channels) in slot GROUP A and
GROUP B at a PG16 or in slot GROUP at a PG8
SANE 1: SANE RJ-45 interface for data transmission + 100 Mbit Ethernet
SANE 2: SANE RJ-45 interface for data transmission + 100 Mbit Ethernet
LINK 1:
LINK 2:
LAN 1:
LAN 2:
Full-duplex, full bandwidth LC-type optical interface for data transmission
Full-duplex, full bandwidth LC-type optical interface for data transmission
100 Mbit RJ-45 Ethernet interface
100 Mbit RJ-45 Ethernet interface
12 PG16-FX and PG8-FX User Guide
6 Device Details
6.1 Fiber Optic Connection
The ProGrid Signal Transport Solution uses a digital Time Division Multiplex technology (TDM) with a fiber channel based 8B10B-NRZI-coding. Static time slots guarantee the synchronous transmission of all channels at any time with no demand for dynamic bandwidth. All signals attached to the audio, video, word clock and auxiliary ports of the device are transmitted simultaneously on one fiber. The second fiber of one LINK-Interface is used to receive data.
The second LINK-Interface has the same features as the first; therefore one of the LINK-Interfaces can always be used for redundancy.
6.2 A/D and D/A Converter
24-bit converters supporting sample rates of 44.1, 48, 88.2, 96, 176.4, 192 kHz ensure the high-quality conversion of analogue audio signals.
6.3 Analog Inputs
The microphone inputs include preamps with selectable gain between -4 dB to 66 dB in analogue 1 dB steps
Phantom Power (+48V) can be activated individually on each input. The maximum input level is +22 dBu.
The line inputs gain controls can be individually adjusted in four steps of maximum input level 27 dBu, 22 dBu,
18 dBu and 8 dBu.
6.4 Analog Outputs
The outputs gain controls can be individually adjusted in four steps of maximum output level 22 dBu, 18 dBu, 12 dBu and 8 dBu.
6.5 SANE Ports
All FX units are equipped with two RJ45 200MBit SANE Ports for 64 channels synchronous audio + 100MBit
Ethernet.
6.6 RS485 Auxiliary Ports
The auxiliary ports provide four RS485 interfaces to establish a maximum of four half-duplex or two full-duplex connections between the devices. A wide range of bi-directional and unidirectional standards can be connected, such as RS485, CAN-Bus (bi-directional), or RS422, DMX, MIDI (unidirectional). The interfaces will sense automatically whether they send or receive control data. OPTOCORE CONTROL software is used for setting the destination of each interface.
6.7 Word Clock
All units are equipped with a Word Clock IN and OUT. Word Clock is also transmitted via the fiber and SANE Ports.
In network configurations no extra BNC cable is needed. The PG16/PG8-FX units are equipped with an internal, high quality and extremely low jitter word clock. Any PG16/PG8-FX can act as master to pass the word clock to further ProGrid or SANE units or other devices. The word clock is available at the word clock OUT BNC-connector of this device. The Word Clock IN is terminated internally, so that no further external termination at the Word Clock Out is needed to avoid cable reflections.
13 PG16-FX and PG8-FX User Guide
6.8 Transmission Delay
The ProGrid system delay including the matrix is fixed to 41.6 µs @ 48 kHz for all channels. The transport delay per
ProGrid unit (<200 ns) in the network is insignificant. The transmission delay is constant from any point to any point.
Overall delay depends on converters and fiber cable length, with ‘normal’ cable lengths of <700 m it can also be considered as marginal.
6.9 Power Supply
The device is optionally equipped with two power inputs and power supply units. If one power supply fails, due to malfunction of the feeding power line or the power supply unit itself, the device will automatically switch over to the other power supply unit. In order to make the power supply redundant, both power inputs must be connected to the mains supply, if possible to different phases, power supply systems, or even better, one of them to an uninterrupted power supply (UPS).
The power supply units operate with mains voltage of 100 ... 240 V and frequency of 50 … 60 Hz. Thus the device can be used throughout the world without any modifications or transformers.
Be aware that the switched-mode power supplies operate with high voltages! Coming into contact with them can lead to considerable electric shock that may result in death! To prevent electric shocks do not remove any covers!
14 PG16-FX and PG8-FX User Guide
7 Control
All system and device parameters are set using OPTOCORE CONTROL on a PC. If the
PG16/PG8-TP units are connected to a FX Device using SANE or PG32-AES-FX using the BI-
B cables as shown in Mains-Connection.
15 PG16-FX and PG8-FX User Guide
8 Channel Allocation
8.1 FX
The standard channel allocation is as follows:
Audio
RS485 Data
Video
256 Channels @ 48 kHz – 1 Gbit network
768 Channels @ 48 kHz – 2 Gbit network
32 Channels
3 CVBS Video Channels *
Ethernet 100 MBit Fast Ethernet *
* If the network is used for transport of Ethernet compatible data the capacity is reduced to one CVBS video channel plus 100 Mbps Fast Ethernet.
8.2 SANE
The standard channel allocation is as follows:
Audio
Ethernet
64 channels @ 48 KHz
100 Mbit Fast Ethernet
16 PG16-FX and PG8-FX User Guide
9 Connectors and Cables
9.1 SANE Ports
Use shielded twisted-4-pair-cable (Cat-5, Cat-5e, Cat-6), with RJ-45 connectors. SANE technology utilises all 4 pairs of Cat-5 cable – two for standard Ethernet transmission, two for SANE. Maximum distance between two devices connected by SANE is 100m.
9.2 Optical Connection
The dual optical LINK-interfaces are equipped with duplex LC connectors. Standard LC cables with two fibers can be used. Worst case reach is 700 m with multimode transceivers and a 50
µ m fiber, while with singlemode transceivers and a 9
µ m fiber, up to 70 km are possible. For rugged applications e.g. touring and other temporary installations,
HMA Expanded Beam Connectors mounted on 1 RU panel are available, along with matching, inter-connection cables transported on cable drums. (Please refer to Product Brochure available at www.clearcom.com
).
9.3 Principal, Auxiliary, and AES Ports
According to the RS422/RS485 hardware standard used for transport of AES/EBU, each channel requires a twisted pair. A common braided shield should enclose the pairs.
For the Analog audio ports, a shielded cable is to be used.
9.4 RS232 Connection
Shielded, standard RS232 cable must be used for the RS232 port.
9.5 RS485 Connection
Shielded, cable must be used for the RS485 port.
9.6 Connector Hood Quality
Applied locking screws for the D-Sub-types must be acc. to 4-40 UNC. Care should be taken in selecting the right types of connector hoods in order to fulfil the requirements of EMI-radiation directives. Full metal connector hoods should be used, approved acc. to VDE 0871, FCC 20780 and EMC directive 2004/108/EG, providing an reduction
>40 dB on 30 MHz up to 1 GHz. The shielding harness of the cable should have complete contact to the connector hood.
9.7 USB-Connection
To the USB-port, use a standard PC/device cable.
9.8 LAN-Connection
Use shielded twisted-pair-cable (Cat-3, Cat-5) with RJ-45 connector.
9.9 Word Clock-Connection
Use 75
Ω
-coaxial-cable with BNC-connector.
17 PG16-FX and PG8-FX User Guide
9.10 Mains-Connection
Standard power cords with IEC C13 sockets can be used.
9.11 Hardware Connection Example
The PG16-FX can be used as a SANE to ProGrid converter. The PG16-FX with analog I/O cards is connected with three PG16-TPs with different types of cards and one PG8-TP by CAT5 cables. The word clock is transmitted by
SANE and ProGrid, so there is no need to use 75
Ω
cables. The following figure demonstrates the configuration of a
32 send, 8 AES and 24 return SANE system which can be combined with a bigger ProGrid ring. In this example there are two ProGrid PG16-TP units using two input cards each - one PG16-TP with two input cards, one PG16-TP with AES in/out card and output card. There is also one PG8-TP with one output card, one PG16-TP with one
DualMic card and one PG16-FX with one input and one output card. All those devices are creating a CAT5 SANE network. The PG16-FX device is used as a bridge between SANE and ProGrid network.
Fig. 1: Connection of three PG16-TP units, one PG8-TP and one PG16-FX.
Each of the devices in this example is an analogue converter with SANE network interface. It is possible to use AES ports which are built in each TP device to input or extract digital audio channels to/from the network. The configuration of the AES ports as inputs and/or outputs and the routing is carried out with OPTOCORE CONTROL. It is possible to route input channels from other devices in an ProGrid ring to the –TP outputs.
The same single CAT5 connection transports audio data, word clock and 100 Mbit Ethernet.
18 PG16-FX and PG8-FX User Guide
10 Starting Up
10.1 Software Installation
Installation requirement for the software is a functioning computer system with Microsoft
Windows 2k (Requires installation of GDIplus.dll), XP 32&64Bit, Vista 32&64Bit, Server2003&2008, Windows7 32&64Bit or Mac: Intel based
Macs with above OS using Bootcamp/Parallels/VMWare. The computer should be equipped with an USB interface for configuration and remote controlling, and a RS232 interface (or an appropriate USB / RS232 converter) for firmware upgrade. COM 1...4 can be used with a transfer rate of 57 600 Baud. Monitor resolutions of 800 x 600 or
1024 x 768 with 16 Bit color rendering are recommended to view the program. The installation requires approx.
2.5MB of hard-disk space and is carried out in the usual Windows-program manner.
Please note that the serial interfaces on computers are usually not capable of “Hot Plugging”. Switch off the computer to avoid damage before establishing the serial connection between the ProGrid device and the computer.
The set-up software 785G041X_PROGRID_CLIENT_SERVER_X_XX.EXE
can be downloaded from www.clearcom.com
or provided by the Clear-Com support team. OPTOCORE CONTROL for configuration and remote controlling, and OPTOCORE UPGRADE for firmware upgrading are installed on a PC or Laptop by doubleclicking on the 785G041X_PROGRID_CLIENT_SERVER_X_XX.EXE.
The set-up executable program is selfextracting and provides the OPTOCORE CONTROL SETUP WIZARD. It will establish the necessary directories, a desktop icon for the OPTOCORE CONTROL and firmware upgrade software.
The uninstall procedure of OPTOCORE CONTROL can be carried out with the ADD OR REMOVE PROGRAMS tool of Windows, which is usually found under START / CONTROL PANEL .
For details about features and handling of OPTOCORE CONTROL please refer to the HELP menu of the software. It is strongly recommended to familiarize yourself with the OPTOCORE CONTROL software.
10.2 ProGrid Network Setup
Before connecting a PG16-FX or PG8-FX to any other device and before establishing the optical LINK connection make sure that all devices have a basic set-up in order to be able to operate correctly. For operation safety reasons, some settings (e.g. “ID”) may only be made when locally connected to a device.
All devices in the network must operate with the same firmware version . The firmware version can be revised under SET / LOCAL SETTINGS. The update of the firmware is done with the OPTOCORE UPGRADE software under START / PROGRAM / OPTOCORE / UPGRADE . Please refer to the HELP Menu for further information. For firmware update the PC has to be connected via the RS232 or USB Port on the front of the device.
The best approach to check the settings is to connect locally to every single device of the ProGrid network with a PC using either RS232 or USB connection, run the OPTOCORE CONTROL software and enter menu
SET / LOCAL SETTINGS . This dialog enables the definition of the ID, ports, etc.
•
General: Set each device in the optical network to a unique ID. Device IDs must be unique in the entire
ProGrid network. Usually the device with the lowest ID and a word clock input will determine the clock of the network. It is advisable to assign ID 1 to the device with word clock input connected to the most important console, e.g. the FOH console.
Master Priority allows forcing a device to act as word clock master of the network. The device with the lowest ID, a checked Master Priority and a word clock input will act as master.
Devices with a word clock input such as PG32-AES-FX, PG16-FX, PG8-FX, PG16-TP, and PG8-TP always have priority prior to devices without word clock input. Thus even if the Master Priority is checked in the local settings of a device without word clock input, the device with the lowest ID and word clock
19 PG16-FX and PG8-FX User Guide
input acts as word clock master of the network, when present.
•
Clock Setup: All devices in the network must work with the same sample rate. CLOCK SOURCE allows the selection of Auto (BNC priority), INT (internal) or BNC (external) word clock signal.
•
RS485 Ports: The RS485 SETUP is used to define, which signal is given out at the specific port of the device. There are 32 data channels available in the network. It is necessary to allocate physical inputs as the 4-channel bank. Four output it is possible to choose one of 32 channels per each port.
•
Video / Ethernet setup: In order to use ProGrid for Ethernet transport, the option System Ethernet should be enabled globally. In PG16-FX and PG8-FX Local Setting it is possible to enable or disable
Local Ethernet as well. While System Ethernet is enabled it is possible to use only the first video channel. Video setup can be done by allocating video input in a proper channel. This channel can be outputted on every device which is equipped with video output.
Click on WRITE first, confirm with OK , and then click CLOSE to exit the dialog.
You may now connect the optical LINK cables between all ProGrid devices.
Check your setup by connecting to any device using either RS232 or USB connection, running the OPTOCORE
CONTROL software and starting ONLINE MODE in the SET menu. The entire network at its current state is now displayed in the control software. Check the LOG WINDOW for any error messages. All ProGrid devices memorize the current setup, even if they are switched off or disconnected from the power supply.
Never switch on power amplifiers before the complete system is stable and the OPTOCORE CONTROL level meters indicate a normal level.
20 PG16-FX and PG8-FX User Guide
11 Connection Tables
Pin-out
+
Each Channel
- GND
Euroblock
Balanced Mic/Line Inputs, Line Outputs
Pin-out Auxiliary Ports 4 x RS485
Channel
Pin
+
-
1
1
6
2
7
RS485
2 3
3
5
8
1
D-Sub-9- female
9 6
Pin-out
Channel
RS232
RXD TXD
Pin 3
Internally bridged
2 1, 4, 6 7, 8
5 1
D-Sub-9- female
9 6
Pin-out
4
4
9
USB
Channel
VBUS D -
Pin 1 2
D +
3
GND
4
GND
5
RS232-Port
Power
+5VS GND
9 5
USB-Port
Please assure correct polarity “+” and “-“ at both (!) sides / devices when connecting external equipment to the RS485 ports.
Locking system acc. to 4-40 UNC
Use standard RS232 cable, male – female, to connect to PC
Locking system acc. to 4-40 UNC
USB device-connector
21 PG16-FX and PG8-FX User Guide
12 Technical Specifications
Analog Audio Mic Inputs
Impedance, Gain / steps
Maximum input level
SNR
THD+N @ -1dBFS
Analog Audio Line Inputs
Impedance, Gain / steps
Maximum input level
SNR
THD+N @ -1dBFS
Analog Audio Line Outputs
Impedance, Gain / steps
Maximum output level
SNR
THD+N @ 0dBFS
Conditions
Word clock
Data rate
Impedance
Drive level
Zero level
Sense level
Remote Control
RS232
USB
LAN
SANE, LAN
Audio
LAN
Optical Connection
Power supply
Type
Mains voltage
Frequency
Power consumption
Security classification
Security regulations
Mains connector
Cooling
ADC
Single and Dual
4.5kΩ
@ -4 dB Gain +22 dBu
@ -4 dB Gain
@ -4 dB Gain
122.5 dB(A)
≤ -102 dB
ADC
@ -9 dB Gain
@ -9 dB Gain
@ -9 dB Gain
DAC
@ +4 dB Gain
@ +4 dB Gain
@ +4 dB Gain
Reference 0dBFS ≡ 18dBu, Input / Output Termination 150R / 300R, Sample Rate
48kHz. Specs noticed as typical, if not otherwise stated
Hardware standard BNC - 75
Ω
Depending on selected sample rate
Output
Input
Output
Referring to GND
Input
Up to 192 kHz
≤ 5 Ω
75
Ω
≥ 1 V pp
+ 1.7 V
≥ 400 mV pp
Convention
EIA / TIA - 232
USB 2.0 - Device
IEEE - 802.3
10kΩ
+27 dBu
127.5 dB(A)
≤ -102 dB
22Ω
+22 dBu
123 dB(A)
≤ -100 dB
Convention
TIA - 568A/B, Optocore
TIA - 568A/B, IEEE - 802.3
-4 dB to +66 dB 1 dB steps
@ +66 dB Gain -48 dBu
@ +66 dB Gain 81.5 dB(A)
@ +40 dB Gain
≤ -100 dB
-9, -4, 0, +10 dB 4 steps
@ +10 dB Gain +8 dBu
@ +10 dB Gain 108 dB(A)
@ +10 dB Gain
≤ -102 dB
+4, 0, -6, -10 dB 4 steps
@ -10 dB Gain
@ -10 dB Gain
@ -10 dB Gain
+8 dBu
108 dB(A)
≤ -103 dB
57 600 Baud
12 Mbit/s
10/100 Mbit/s
200 Mbit/s
10/100 Mbit/s
Complies with 21 CFR 1040.10 and 1040.11
Switch-mode, universal input
100 … 240 V
50 … 60 Hz
Depending on device, 32VA - Max
Class 1: basic insulation, connected to the protective grounding conductor
Harmonised European standard EN60065 acc. to IEC-950
Passive, via surface and ventilation-slits on both sides
22 PG16-FX and PG8-FX User Guide
13 Dimensions and Weight
Front panel: width 483 mm / 19 inch
height 44 mm / 1.73 inch
depth 200 mm / 7.87 inch
Rear panel: width 438 mm / 17.25 inch
Weight
2.7 kg ≡ 4.41 lbs
Modifications that serve the purpose of technical improvement of the device may be carried out without prior notification.
23 PG16-FX and PG8-FX User Guide
14 Compliance
FCC notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communication. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by Clear-Com, LLC, an HM Electronics, Inc. company could void the user’s authority to operate this equipment.
IC Notice:
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne peut pas provoquer d’interférences, et (2) cet appareil doit supporter toute interférence, y compris des interférences qui pourraient causer un mauvais fonctionnement de l'appareil.
Industry Canada Compliance Statement
This Class[A] digital device complies with Canadian ICES-003.
Avis de conformité à la réglementation d'Industrie Canada
Cet appareil numérique de la class[A] est conforme à la norme NMB-003 du Canada.
The PG16-FX and PG8-FX products comply with the following specifications:
EN55022 Emissions
EN55024 Immunity
Electromagnetic Compatibility Directive 2004/108/EC
Low Voltage Directive 2006/95/EC
Warning:
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Waste Electrical And Electronic Equipment (WEEE)
The European Union (EU) WEEE Directive (2002/96/EC) places an obligation on producers
(manufacturers, distributors and/or retailers) to take-back electronic products at the end of their useful life. The WEEE Directive covers most Clear-Com products being sold into the EU as of
August 13, 2005. Manufacturers, distributors and retailers are obliged to finance the costs of
24 PG16-FX and PG8-FX User Guide
recovery from municipal collection points, reuse, and recycling of specified percentages per the
WEEE requirements.
Instructions for Disposal of WEEE by Users in the European Union
The symbol shown below is on the product or on its packaging which indicates that this product was put on the market after August 13, 2005 and must not be disposed of with other waste.
Instead, it is the user’s responsibility to dispose of the user’s waste equipment by handing it over to a designated collection point for the recycling of WEEE. The separate collection and recycling of waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local authority, your household waste disposal service or the seller from whom you purchased the product.
Figure 14-1: WEEE Symbol
25 PG16-FX and PG8-FX User Guide
15 Warranty and Liability
The Clear-Com product that you have purchased is covered by the Clear-Com
Standard Limited Warranty, the terms and conditions of which can be found at www.clearcom.com/support/warranty-support-policies . We encourage you to review the
Standard Limited Warranty to determine its coverage, exclusions from coverage and duration.
EXCEPT AS SET FORTH IN THE STANDARD LIMITED WARRANTY, CLEAR-COM
MAKES NO WARRANTIES REGARDING THE PRODUCT, EXPRESS, IMPLIED OR
STATUTORY, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF
MERCHANTABILITY, NONINFRINGEMENT OF THIRD PARTY RIGHTS, OR
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH ARE EXPRESSLY
DISCLAIMED.
NOTE: Warranty of the ProGrid devices will be invalidated by the use of fiber transceivers not approved or supplied through Clear-Com or its approved dealers.
26 PG16-FX and PG8-FX User Guide
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Document Reference
- 5 Important Safety Instructions
- 5 Operating and Storage Temperature
- 5 Eye Safety
- 6 Safety symbols
- 7 Device Description
- 9 Card Types
- 10 Front Panel
- 10 PG16-FX
- 10 PG8-FX
- 12 Rear Panel
- 12 PG16-FX with Analogue Input- and Output Cards
- 12 PG8-FX or PG16-FX with Dual Microphone
- 13 Device Details
- 13 Fiber Optic Connection
- 13 A/D and D/A Converter
- 13 Analog Inputs
- 13 Analog Outputs
- 13 SANE Ports
- 13 RS485 Auxiliary Ports
- 13 Word Clock
- 14 Transmission Delay
- 14 Power Supply
- 15 Control
- 16 Channel Allocation
- 17 Connectors and Cables
- 17 SANE Ports
- 17 Optical Connection
- 17 Principal, Auxiliary, and AES Ports
- 17 RS232 Connection
- 17 RS485 Connection
- 17 Connector Hood Quality
- 17 USB-Connection
- 17 LAN-Connection
- 17 Word Clock-Connection
- 18 Mains-Connection
- 18 Hardware Connection Example
- 19 Starting Up
- 19 Software Installation
- 19 ProGrid Network Setup
- 21 Connection Tables
- 22 Technical Specifications
- 23 Dimensions and Weight
- 24 Compliance
- 26 Warranty and Liability