advertisement
![Promax CT-193 Current clamp for AC and DC (600 V, 700 A) Datasheet | Manualzz Promax CT-193 Current clamp for AC and DC (600 V, 700 A) Datasheet | Manualzz](http://s3.manualzz.com/store/data/054102370_1-75a8d268bcac3c26130972db9cd8fcee-360x466.png)
CT-193
CURRENT CLAMP
INCLUDES IMPEDANCE & FREQUENCY
MEASUREMENT, CONTINUITY
AND DIODE TEST
The CT-193 current clamp features voltage, current and resistance measurement and includes continuity acoustic indication, diode test as well as frequency measurement.
Three buttons enable to select functions such as data HOLD, MAX value and zeroing for DC currents measurement (DCA ZERO).
The meter is supplied by a 9 V battery. Its design and double isolation make the CT-193 a safe, rugged instrument.
MEASUREMENTS INCLUDED IN THE CURRENT CLAMP CT-193
ü DC voltage:
Up to 600 V
ü
DC current: Up to 700 A
ü Continuity measurement:
Acoustic indicator
ü
Impedance: Up to 200 kΩ
ü AC voltage:
Up to 600 V (from 50 to 500 Hz)
ü
AC current: Up to 700 A (from 40 to 500 Hz)
ü Diode test:
Acoustic indicator
SPECIFICATIONS
ü
Display: Loquid crystal LCD screen with negative polarity indication
ü
Polarity: Automatic, with on-screen indication
ü
Zeroing: Automatic
ü
Dimensions: 250 (W.) x 100 (H.) x 46 (D.) mm
ü
Functions: Data HOLD and MAX hold
ü
Overrange: On-screen indication
ü
Reading rate: 2.5 measurements per second
ü
Power supply: 9 V battery
www.promaxelectronics.com
SPECIFICATIONS
Display
Display functions
Polarity
Overrange
Zeroing
Reading rate
DC voltage
Scale
Accuracy
Input impedance
Overload protection
AC current (50-500 Hz)
Scales
Accuracy
Input impedance
Overload protection
Resistencia
Scales
Accuracy
Open circuit voltage
Overload protection
Frecuencia (autorrango)
Scales
Accuracy
Sensitivity
Overload protection
Continuidad
Acoustic indication
Overload protection
Diode test
Test current
Accuracy
Open circuit voltage
Acoustic indication
Overload protection
DC current
Scales
Resolution
Accuracy
Overload protection
AC current (40 to 500 Hz)
Scales
Resolution
Accuracy
Overload protection
Power supply
Mechanical features
Included accessories
CT-193 CURRENT CLAMP
FOR AC/CC 600 V, 700 A
CT-193 CURRENT CLAMP FOR AC/CC 600 V, 700 A
Liquid crystal (LCD) 3½ screen, max lecture of 1999.
Data HOLD and MAX (keep the maximum value of the measurement)
Automatic: Positive by default and negative polarity indication.
(OL) or (-OL) indication is displayed.
Automatic
2.5 measurements per second, nominal.
600 V
±(0.5% reading + 1 digit)
10 MΩ
600 V DC/AC RMS
200 V, 600 V
±(1.2% reading + 4 digits)
10 MΩ
600 V DC/AC RMS
2 kΩ, 200 kΩ
±(1.2% reading + 1 dígito)
0,3 V DC
600 V DC/AC RMS
2 kHz, 20 kHz
±(0.1% reading + 3 digits) for any scale
80 V RMS min.
600 V DC/AC RMS
Less than 30 Ω in the kΩ scale
600 V DC/AC RMS
1 mA ±0.6 mA
±(6% reading + 3 digits)
3 V DC typ.
< 30 mV
600 V DC/AC RMS
200 A, 700 A
100 mA
±(1.5% reading + 5 digits)
700 A DC máx. for 1 minute
200 A, 700 A
100 mA
From 50 to 60 Hz: ±(1.75% reading + 5 digits)
From 40 to 500 Hz: ±(3.5% reading + 5 digits)
700 A (50/60 Hz): ±(2.5% reading + 5 digits)
700 A AC max. for 1 minute
9 V IEC 6F22 battery; on-screen low battery warning
250 (W.) x 100 (H.) x 46 (D.) mm / 380 g, including the battery
PP-08 test probes couple, Transport case
Accuracy data referred to these environmental conditions: 23 °C ±5 °C, RH < 75%.
PROMAX ELECTRONICA, S. L.
Francesc Moragas, 71 * 08907 L'HOSPITALET DE LLOBREGAT * BARCELONA * SPAIN
Tel: (+34) 93 184 77 02 * e-mail:[email protected] * https://www.promaxelectronics.com
advertisement