Owner’s Manual & Safety Instructions

Save This Manual

Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number).

Keep this manual and the receipt in a safe and dry place for future reference.

17k

Visit our website at: http://www.harborfreight.com

Email our technical support at: [email protected]

When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call 1-888-866-5797 as soon as possible.

Copyright © 2017 by Harbor Freight Tools ® . All rights reserved.

No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools.

Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein.

Tools required for assembly and service may not be included.

Read this material before using this product.

Failure to do so can result in serious injury.

SAVE THIS MANUAL.

IMPORTANT SAFETY INFORMATION

In this manual, on the labeling, and all other information provided with this product:

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.

NOTICE is used to address practices not related to personal injury.

WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION, without the safety alert symbol, is used to address practices not related to personal injury.

General Safety Warnings

WARNING! Read all safety warnings and instructions. Save all warnings and instructions for future reference.

1. Avoid direct eye exposure to laser light.

Do not direct the laser beam into the eyes of any person or animal. Doing so may cause severe eye injury or permanent blindness.

2. Verify Laser Level is in the “Off” position before making any adjustments or changing the batteries.

3. Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.

Position batteries in proper polarity. Do not use swollen or leaking batteries.

4. Remove batteries if Laser Level is not to be used for a long period of time.

5. The Laser Level is a delicate instrument; do not drop or jar the Laser Level.

6. If installing on a wall surface without the Tripod (3), verify that installation surface has no hidden utility lines before drilling or driving screws.

7. Keep work area clean and well lit.

8. This product is not a toy.

Keep it out of reach of children.

9. Keep children and bystanders away while operating Laser Level.

10. Inspect before every use; do not use if parts are loose or damaged.

11. Stay alert, watch what you are doing and use common sense when operating Laser Level.

Do not use Laser Level while you are tired or under the influence of drugs, alcohol or medication.

12. Dress properly. Do not wear loose clothing or jewelry. Keep your hair, clothing and gloves away from moving parts.

13. Maintain labels and nameplates on the tool. These carry important safety information. If unreadable or missing, contact

Harbor Freight Tools for a replacement.

14. The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.

SAVE THESE INSTRUCTIONS.

Page 2 For technical questions, please call 1-888-866-5797.

Item 64000

Specifications

Laser Range Projects Up to 100′

Max. Tripod Height 48″

Rotation Capacity

Batteries

360°

(4) ‘AA’ Batteries

Rotary Laser Level

64000

WARNING

To prevent serious injury and blindness: Do not use included goggles for eye protection.

Read manual before use.

Serial:

17k

LASER LIGHT

AVOID DIRECT EYE EXPOSURE

Max. Output: 3 - 5 mW,

Wavelength: 635 - 670 nm

CLASS II LASER PRODUCT

This product complies with

21 CFR 1040.10 and 1040.11

Distributed by Harbor Freight Tools

3491 Mission Oaks Blvd.

Camarillo, CA 93011 64000

Manufacture Date: ___________, _______

Instructions for Putting Into Use

Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:

Turn the Power Switch to Off before adjusting Level.

Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram on the last page.

Installing The Batteries

1. Loosen the Battery Cover Knob (5A) and remove the

Battery Cover (2A). See Figure A, below.

NOTE: The Knob will NOT come all the way out.

2. Install four ‘AA’ Batteries, making sure to follow the polarity marked in the Battery Compartment.

3. Replace the Battery Cover and turn Battery

Cover Knob until Cover is secured into place.

insert batteries here

Battery Cover

Knob (5A)

Battery

Cover (2A)

Item 64000

Figure A

For technical questions, please call 1-888-866-5797.

Page 3

Mounting To Tripod (3)

1. If mounting the Laser Level with the Tripod (3), position the Tripod on a flat and level ground surface.

Extend Tripod Legs to the desired height, using the

Bull’s Eye Vial (15) located on the Tripod Head (4).

See Figure B, below.

3. Then thread Wall Bracket (7A) onto

Tripod Head. See Figure C, below.

Wall

Bracket

(7A)

Tripod

Head (4)

Tripod

Head (4)

Height

Adjusting

Handle (13)

Bull’s Eye

Vial (15)

Tripod

(3) Height

Locking

Knob (14)

Figure B

2. Once the Tripod is level, lock the legs in place using the clamps on each leg.

Figure C

4. Once the Wall Bracket (7A) is secured on the head, you can use the Height Adjusting Handle (13) to raise the Level Housing to the desired height. Once the desired height is reached, lock the height in place by turning the Height Locking Knob (14). See Figure C.

Mounting To Wall

1. The Laser Level may also be installed on a wall surface without the Tripod. To do so, use the Wall

Bracket (7A) to secure the Laser Level to the wall.

2. First, set the Level Housing against the part of the wall where you wish to install the Laser Level.

WARNING! Verify that installation surface has no hidden utility lines before drilling or driving screws.

3. Use a pencil to mark drill holes through the

Wall Bracket (7A). See Figure D, below.

Wall

Bracket

(7A)

4. Secure the Laser Level to the wall surface using screws and wall anchors (not included). NOTE: The mounting screws must be long enough to allow for the Wall Bracket frame to fit over them.

5. Once installed on wall, level the Laser, using the Leveling Knobs (8A) located on each side of the Laser and the Level

Vials (9A) located at the top of the Laser.

Page 4

Figure D

For technical questions, please call 1-888-866-5797.

Item 64000

Operating Instructions

Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

Initial Leveling

1. When the Laser Level is properly positioned, activate the Laser by turning the Power /

Rotation Control Switch (11A), clockwise.

Then recheck the Level Vials (9A) to make sure the Laser Level has not been bumped or moved.

2. The rotation speed of the Laser Head Cover (6A) can be set by adjusting the Rotation Control Switch.

Turn clockwise to make the beam rotate faster.

Turn counterclockwise to slow the beam down.

3. Mark the desired measurement(s).

Then turn off the Laser Level by turning the Rotation

Control Switch counterclockwise all the way.

Equalizing Height Of Distant Objects

1. For example, if you wish to install cement footings for a storage shed, first determine the desired height of any one of the footings.

3. Direct laser beam toward each of remaining footing locations. On reference stakes at those locations, mark the spot the Laser illuminates.

This indicates desired top surface of that footing.

2. Align the laser beam with the top surface of the reference footing, and check to make sure the

Vial Levels (9A) are level with the ground.

4. This technique can be used for many similar applications, i.e., to align pictures on a wall.

Installing Horizontal Or Vertical Objects

1. For example, to install a chair rail on an interior wall, first mark the desired height of the rail.

4. Then, install the chair rail in a direct line between the two points.

2. Align the Laser Level with that point, and check to make sure the Vial Levels (9A) are level with the floor.

5. This technique can be used to install vertical or 45 degree angle objects.

3. Shine laser beam on the adjoining wall, and have an assistant mark that location.

Checking a Slope

1. For example, to determine the slope of a floor, place the Laser Level at one end of the floor, using the Tripod (3).

2. Check to make sure the Vial Levels (9A) are level.

3. Measure the vertical drop from the

Laser Lens to the floor surface.

4. Shine the laser beam on a ruler held vertical at the other end of the floor. The difference in these measurements is the amount of slope in the floor.

5. This technique can be used to design slope, such as when constructing an outdoor surface which will require a runoff slope.

Item 64000 For technical questions, please call 1-888-866-5797.

Page 5

Maintenance and Servicing

Procedures not specifically explained in this manual must be performed only by a qualified technician.

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:

Turn OFF the Laser Level before performing any inspection, maintenance, or cleaning procedures.

TO PREVENT SERIOUS INJURY FROM TOOL FAILURE: Do not use damaged equipment.

If abnormal noise or vibration occurs, have the problem corrected before further use.

Cleaning, Maintenance, and Lubrication

1. BEFORE EACH USE, inspect the general condition of the Laser Level. Check for loose hardware, misalignment or binding of moving parts, cracked or broken parts, and any other condition that may affect its safe operation.

2. AFTER USE, wipe external surfaces of the tool with clean cloth. Do not immerse the Laser Level in any liquids.

3. Store the Laser Level indoors and out of children’s reach.

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM

IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR

MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS

QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE

ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY

STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND

LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY

ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS

THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

Page 6 For technical questions, please call 1-888-866-5797.

Item 64000

2A

7A

Parts List and Assembly Diagram

Part Description

1A ‘AA’ Battery (not included)

2A Battery Cover

3

4

Tripod

Tripod Head

5A Battery Cover Knob

6A Laser Head Cover

7A Wall Bracket

8A Leveling Knob

Qty.

4

1

1

1

3

1

1

1

Part

9A Level Vial

Description

10A Level Housing

11A Power / Rotation Control Switch

12 Glasses (not shown)

13 Height Adjusting Handle

14 Height Locking Knob

15 Bull’s Eye Vial

16 Target with stand and magnet

5A

6A

15

14

9A

Qty.

3

1

1

1

1

1

1

1

4

13

3

10A

11A

8A

16

Record Product’s Serial Number Here:

Note: If product has no serial number, record month and year of purchase instead.

Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts.

Parts not shown to scale.

Item 64000 For technical questions, please call 1-888-866-5797.

Page 7

LIMITED 90 DAY WARRANTY

Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.

To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise.

If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • 1-888-866-5797

advertisement

Key Features

  • Projects visible laser lines for precise leveling and alignment
  • 360-degree rotation for all-around visibility
  • Long range of up to 100 feet for large areas
  • Maximum tripod height of 48 inches for optimal visibility
  • Simple and easy-to-use controls for quick setup and operation
  • Compact and lightweight design for easy portability and storage

Related manuals

Frequently Answers and Questions

What is the maximum range of the laser level?
The laser level has a maximum range of up to 100 feet.
Can I use the laser level without a tripod?
Yes, you can install the laser level on a wall surface without using the tripod. However, you should verify that the installation surface has no hidden utility lines before drilling or driving screws.
How many batteries does the laser level require?
The laser level requires four 'AA' batteries.
What is the maximum tripod height?
The maximum tripod height is 48 inches.
How do I install the batteries?
Loosen the Battery Cover Knob, remove the Battery Cover, insert four 'AA' batteries following the polarity marked in the Battery Compartment, replace the Battery Cover, and turn the Battery Cover Knob until the Cover is secured into place.
Download PDF