Polycom G7500 Reference Manual
Polycom G7500 is a powerful video conferencing system that offers a range of features to help you connect with colleagues, customers, and partners around the world. With its high-quality video and audio, easy-to-use interface, and flexible configuration options, the Polycom G7500 is the perfect solution for businesses of all sizes.
Advertisement
Advertisement
REFERENCE GUIDE
2.0 | May 2019 | 3725-85855-001A
Polycom
®
G7500 Configuration
Parameters
Copyright
©
2019, Polycom, Inc. All rights reserved. No part of this document may be reproduced, translated into another language or format, or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Polycom, Inc.
6001 America Center Drive
San Jose, CA 95002
USA
Trademarks
Polycom
®
, the Polycom logo and the names and marks associated with Polycom products are trademarks and/or service marks of Polycom, Inc. and are registered and/or common law marks in the
United States and various other countries.
All other trademarks are property of their respective owners. No portion hereof may be reproduced or transmitted in any form or by any means, for any purpose other than the recipient's personal use, without the express written permission of Polycom.
End User License Agreement
By installing, copying, or otherwise using this product, you acknowledge that you have read, understand and agree to be bound by the terms and conditions of the End User
License Agreement for this product. The EULA for this product is available on the Polycom Support page for the product.
Patent Information
The accompanying product may be protected by one or more U.S. and foreign patents and/or pending patent applications held by Polycom, Inc.
Open Source Software Used in this Product
This product may contain open source software. You may receive the open source software from Polycom up to three (3) years after the distribution date of the applicable product or software at a charge not greater than the cost to Polycom of shipping or distributing the software to you. To receive software information, as well as the open source software code used in this product, contact Polycom by email at [email protected]
(for video products) or
(for voice products).
Disclaimer
While Polycom uses reasonable efforts to include accurate and up-to-date information in this document, Polycom makes no warranties or representations as to its accuracy. Polycom assumes no liability or responsibility for any typographical or other errors or omissions in the content of this document.
Limitation of Liability
Polycom and/or its respective suppliers make no representations about the suitability of the information contained in this document for any purpose. Information is provided "as is" without warranty of any kind and is subject to change without notice. The entire risk arising out of its use remains with the recipient. In no event shall Polycom and/or its respective suppliers be liable for any direct, consequential, incidental, special, punitive or other damages whatsoever (including without limitation, damages for loss of business profits, business interruption, or loss of business information), even if Polycom has been advised of the possibility of such damages.
Customer Feedback
We are striving to improve our documentation quality and we appreciate your feedback. Email your opinions and comments to [email protected]
.
Polycom Support
Visit the Polycom Support Center for End User License Agreements, software downloads, product documents, product licenses, troubleshooting tips, service requests, and more.
Contents
Using Provisioning Service Credentials to Register with an LDAP Directory....................17
Polycom, Inc.
1
Microsoft Exchange Server Parameters........................................................ 38
Using Provisioning Service Credentials to Register with a Calendaring Service.............. 38
Configure Common and Per-Camera Parameters................................................. 89
Contents
Polycom, Inc.
2
Before You Begin
Topics:
▪
This guide lists the available configuration parameters for provisioning your Polycom G7500 system.
Getting Help
For information about installing, configuring, using, and administering Polycom products, see
Documents
& Software
at Polycom Support .
The Polycom Community
The Polycom Community gives you access to the latest developer and support information.
Participate in discussion forums to share ideas and solve problems with your colleagues. To register with the Polycom Community, simply create a Polycom online account. When logged in, you can access
Polycom support personnel and participate in developer and support forums to find the latest information on hardware, software, and partner solutions topics.
Related Documentation
In addition to this guide, the following documentation further describes Polycom endpoints and peripherals used in video conferencing. The Release Notes might include known issues or limitations related to interoperability with Polycom endpoints.
For more information, see the Polycom Documentation Library or Polycom Support .
▪
Polycom
®
G7500 Administrator Guide
▪
Polycom
®
G7500 Release Notes
Documentation Feedback
We welcome your feedback to improve the quality of Polycom documentation.
You can email Documentation Feedback for any queries or suggestions related to this documentation.
Polycom, Inc.
3
Getting Started
Topics:
▪
▪
Automatic Provisioning with RealPresence Resource Manager
You can use the configuration parameters described in this guide to provision single or multiple Polycom
G7500 systems.
Understanding Parameter Lists
The following describes a general convention for details you can find in parameter lists. Parameter details can vary depending on the complexity of the parameter.
parameter.name
A parameter’s description, applicability, or dependencies, as needed.
The parameter’s permitted values, default value, and the value’s unit of measure (such as seconds, Hz, or dB).
A
Note:
that highlights critical information you need to know.
Automatic Provisioning with RealPresence Resource
Manager
By default, the RealPresence Resource Manager system automatically provisions some G7500 system settings for you using a special configuration value (for example, voIpProt.SIP.userName=
“$
{sip_alias}”
).
The following parameters support automatic configuration values: device.local.deviceName=“${device_name}” dir.ldap.server.address=“${ldap_serveraddress}” dir.ldap.baseDN=“${ldap_baseDN}” dir.ldap.defaultGroupDN=“${ldap_defaultgroupDN}” voIpProt.H323.name=“${h323_ID}” voIpProt.H323.e164=“${h323_e164}” voIpProt.SIP.userName=“${sip_alias}”
These parameters are provisioned by default, so you won’t see them in the profiles provided by the
RealPresence Resource Manager system. You can overwrite these parameters with your own values (for example, voIpProt.SIP.userName=
“meetingSpace”
).
You also can automatically generate new values by resetting these parameters with a special configuration value (for example, voIpProt.H323.e164=
“${h323_e164}”
). However, you can’t rename existing endpoints by setting device.local.deviceName=
“${device_name}”
because that value is applied only to new endpoints.
For more information, see the RealPresence Resource Manager documentation .
Polycom, Inc.
4
Audio Parameters
Topics:
▪
This section describes available audio configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Audio Parameters
Use the following parameters to configure audio settings on your G7500 system.
voice.acousticFence.enable
Specifies if you want to enable Polycom Acoustic Fence technology.
This setting is disabled if you set voice.stereo.enable="1".
0 (default)
1
voice.acousticFence.radius
Specifies the sensitivity of the Polycom Acoustic Fence technology, where 0 is the minimum microphone sensitivity and 10 is the maximum.
Higher values increase the radius of the fence area around the primary microphone.
0-10 (default is 5)
voice.alertTone
Specifies the audible tone for user alerts.
Tone_1 (default)
Tone_2
Tone_3
Tone_4
voice.in.hdmi.level
Sets levels for the left and right channels of the HDMI audio input.
0-10 (default is 5)
voice.in.3p5.level
Sets levels for the left and right channels of the 3.5 mm stereo audio input.
0-10 (default is 5)
voice.in.3p5.playbackOption
Specifies how audio from the 3.5 mm stereo audio input is routed and controlled.
Playback to All Locations (default) - The 3.5 mm stereo audio input is heard on the system's speakers and at far sites. Mute control and echo cancellation for this audio source aren't available. Set this value if you’re sharing audio from a device.
Polycom, Inc.
5
Audio Parameters
Playback to Far Sites, Mute Controlled, Echo Cancelled - The 3.5 mm stereo audio input is heard at far sites but not on the system's speakers. You can mute all audio, and echo cancellation is enabled. Set this value if you’re using a line-in microphone.
voice.liveMusicMode.enable
Specifies whether the system uses M-Mode, which transmits audio using a configuration that best reproduces interactive and live performance music picked up by microphones. This feature provides the highest-possible bandwidth for audio.
When M-Mode is enabled, even the faintest musical notes come through clearly.
0 (default)
1
Note:
Noise reduction features are disabled when M-Mode is enabled.
voice.muteReminder.enable
Specifies if a notification displays indicating microphones are muted when speaking is detected.
1 (default)
0
voice.noiseSuppression.enable
Specifies whether the system microphones are muted when keyboard typing or other extraneous noises are detected but no one is talking. NoiseBlock unmutes the system when speech is detected, regardless if there’s background noise.
When you enable M-Mode (voice.liveMusicMode.enable="1"), this feature is disabled. If an external echo canceller is used, keyboard noise reduction is not available.
0 (default)
1
voice.out.line.mode
Specifies how the volume for a device connected to the line out port is confgured: variable (default) - Allows users to set the volume with the remote control.
fixed - Sets the volume to the audio level configured for the system.
voice.ringTone
Specifies the ringtone for incoming calls.
Tone_1 (default)
Tone_2
Tone_3
Tone_4
Tone_5
Tone_6
Tone_7
Tone_8
Tone_9
Polycom, Inc.
6
Audio Parameters
Tone_10
voice.stereo.enable
Enables Polycom StereoSurround software for all calls.
This setting is disabled if you set voice.acousticFence.enable="1".
0 (default)
1
voice.toneControl.bass
Sets the volume level for the low frequencies without changing the master audio volume.
+6
+4
+2
0 (default)
-2
-4
-6
voice.toneControl.treble
Sets the volume level for the high frequencies without changing the master audio volume.
+6
+4
+2
0 (default)
-2
-4
-6
voice.volume.soundEffects
Sets the volume level of the ringtone and user alert tones.
0-10 (default is 3)
voice.volume.speaker
Sets the main audio output volume level going to the speakers.
Even numbers from 0-100 (default is 50)
voice.volume.transmitLevel
Specifies the audio level, in decibels, at which to transmit sound. Unless otherwise advised,
Polycom recommends setting this value to 0 dB.
-6-18 (default is 0)
voice.muteInSleep
If set to "1", microphones are muted when the system goes to sleep.
0 (default)
Polycom, Inc.
7
1
Audio Parameters
Polycom, Inc.
8
Bluetooth Parameters
Topics:
▪
This section describes available Bluetooth configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Bluetooth Parameters
Use the following parameter to configure the Bluetooth setting on your G7500 system.
bluetooth.enable
Turns system Bluetooth features on or off.
Disabling Bluetooth turns off screen mirroring with AirPlay-certified devices and prevents those devices and the Polycom Content App from automatically discovering your system. (You can still connect with the Polycom Content App using the system IP address.)
1 (default)
0
Polycom, Inc.
9
Call Parameters
Topics:
▪
Configuring Dialing Preferences
▪
This section describes available call configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Configuring Dialing Preferences
Remember the following when provisioning dialing preferences for your G7500 system:
▪ To successfully provision a dialing preference, the corresponding call protocol (SIP or H.323) must be enabled. For example, you must configure voIpProt.H323.enable=
"1"
to set call.videoDialPreference.1=
"h323"
.
▪ To configure a secondary dialing preference, you must set voIpProt.H323.enable and voIpProt.SIP.enable to
"1"
.
▪ If you enable SIP and H.323, you must configure primary and secondary dialing preferences.
▪ You can't configure your primary and secondary dialing preferences with the same value. For example, call.videoDialPreference.1 and call.videoDialPreference.2 cannot both be set to
"sip"
.
▪ You can't configure call.voiceDialPreference.1 or call.voiceDialPreference.2 if call.audioOnly.enable=
"0"
.
Call Parameters
Use the following parameters to configure call settings on your G7500 system.
call.autoAnswer.micMute
Specifies whether to mute incoming calls.
1 (default)
0
call.conference.joinLeaveTone.enable
Plays an audible tone when someone joins or leaves a conference call.
1 (default)
0
call.autoAnswer.answerP2PCall
Sets whether the system answers an incoming call when not in a call.
If set to "Do_Not_Disturb", incoming calls are rejected without notification.
No (default)
Yes
Polycom, Inc.
10
Call Parameters
Do_Not_Disturb
call.displayIconsInCall
Specifies whether to display onscreen graphics, including icons and help text, during calls.
1 (default)
0
call.maxTimeInCall
Sets the maximum number of hours allowed for a call.
When that time expires, you're prompted if you want to hang up. If you don't answer within one minute, the call automatically ends. If you choose to stay in the call, you aren't prompted again.
8_hours (default)
1_hour
2_hours
3_hours
4_hours
5_hours
6_hours
7_hours
9_hours
10_hours
11_hours
12_hours
24_hours
48_hours
call.preferredPlaceACallNav
Specifies the default options that display on the local interface place a call screen.
keypad (default) - Displays recently-dialed numbers and a dialpad.
globaldir - Displays a screen for searching a directory. The multitiered directory (LDAP) root entry displays at the top of the Contacts list, which combines your search results and favorites.
recentcalls - Lists previous calls in chronological order.
call.audioOnly.enable
Lets you place audio-only calls on the system.
1 (default)
0
call.h239.enable
Allows the use of a standards-based specification for parallel video streams (i.e., people and content). Enable if you know call participants support H.239.
1 (default)
0
Polycom, Inc.
11
Call Parameters
call.preferredSpeed.maxIncoming
Calls are received at no higher than the speed set here.
128
256
384
512
768
1024
1472
1920
2048
3072
3840
4096
6144 (default)
call.preferredSpeed.outgoing
1920
2048
3072
3840
4096
6144
Determines the IP call speed your system uses when the call is placed from the directory.
128
256
384
512
768
1024 (default)
1472
Note:
If the far-site system does not support the selected speed, a lower speed is automatically negotiated.
call.videoDialPreference.1
Specifies your first preference for how the system places video calls to directory entries with more than one type of number.
sip (default) h323
Polycom, Inc.
12
Call Parameters
call.videoDialPreference.2
Specifies your second preference for how the system places video calls to directory entries with more than one type of number.
h323 (default) sip
call.voiceDialPreference.1
Specifies your first preference for how the system places audio calls to directory entries with more than one type of number.
sip (default) h323
call.voiceDialPreference.2
Specifies your second preference for how the system places audio calls to directory entries with more than one type of number.
h323 (default) sip
call.encryption.requireAES
Specifies how you want to use AES encryption for calls.
When_Available (default) - AES encryption is used with systems that support it, but unencrypted calls also are allowed.
Required_Video - AES encryption is used in all video calls. Calls with systems that don't support fail.
Required_All - AES encryption is used in all types of calls. Calls with systems that don't support fail.
Off - AES encryption is disabled.
call.cdr.enable
Call detail records (CDRs) are included in the system logs. When disabled, the system does not write call information.
1 (default)
0
call.recentCalls.enable
Specifies whether to show recent calls on the local and system web interfaces.
1 (default)
0
call.recentcalls.maxNumberToDisplay
The maximum number of calls displayed in the recent calls list.
25
50
75
100 (default)
Polycom, Inc.
13
Call Parameters
call.escalate2MCU.enable
If set to "1", a point-to-point call on your system can escalate to an impormptu conference call on an external Polycom MCU.
Calls converted through a RealPresence DMA system gateway (H.323 to SIP or vice versa) won’t join an impromptu conference call.
To use this feature, make sure you set the relevant voIpProt.SIP.* parameters to register your system with a Polycom RealPresence Distributed Media Application (DMA) system. You also must set call..escalate2MCU.conferenceId.
0 (default)
1
call.escalate2MCU.conferenceId
Specifies the conference factory ID associated with the SIP conference factory on your
RealPresence DMA system.
Integer (0-128)
Note:
The conference factory ID should come from the same RealPresence DMA system your video-conferencing system uses for SIP registration. Calls won’t escalate if the ID you provide isn’t recognized by your RealPresence DMA system.
Polycom, Inc.
14
Cloud Parameters
Topics:
▪
This section describes available cloud configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Cloud Parameters
Use the following parameter to configure cloud settings on your G7500 system.
cloud.polycom.analytics.enable
Specifies if you want your system to send anonymous usage data to Polycom to help improve its products.
Information collected includes: basic device details, including hardware and software versions; basic device configuration data; device or feature usage statistics; and device health data, including CPU and memory usage.
1 (default)
0
Polycom, Inc.
15
Content Parameters
Topics:
▪
This section describes available cloud configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Content Parameters
Use the following parameters to configure content sharing settings on your G7500 system.
content.conference.qualityPreference
Specifies which video stream has precedence when attempting to compensate for network loss.
The selected stream experiences less quality degradation during network loss compensation than the other. Choosing Both streams means that each experiences roughly equal degradation.
You don't need to set this parameter if content.conference.autoAdjustBandwidth="1".
Both
People
Content
content.miracast.enable
Enable or disable screen mirroring with Miracast-certified devices.
1
0
content.airplay.enable
Enable or disable screen mirroring with AirPlay-certified devices.
1
0
device.net.contentSave.enable
Allow or deny users the ability to save content using the Polycom Content App when connected to the system through your primary network (i.e., LAN).
1 (default)
0
device.net.secondaryNetwork.contentSave.enable
Allow or deny users the ability to save content using the Polycom Content App when connected to the system through your Wi-Fi network.
0 (default)
1
Polycom, Inc.
16
Directory Parameters
Topics:
▪
Using Provisioning Service Credentials to Register with an LDAP Directory
▪
This section describes available directory configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Using Provisioning Service Credentials to Register with an LDAP Directory
You can register your G7500 system with an LDAP directory using the same credentials you used to register with your provisioning service.
To do this, set dir.ldap.auth.useLoginCredentials=“1”
.
With this parameter, provisioning separate username, password, and domain parameters for the directory service isn’t necessary. For example, if you set dir.ldap.auth.useLoginCredentials=“1”
, you don’t have to set dir.ldap.auth.userId, dir.ldap.auth.password, and dir.ldap.auth.domain.
Directory Parameters
Use the following parameters to configure directory settings on your G7500 system.
dir.gds.auth.password
The Polycom GDS password, if one exists.
String
dir.gds.server.address
Specifies the IP or DNS address of the Polycom GDS.
String
dir.ldap.auth.domain
Specifies the domain name for registering with the LDAP server.
String (0-128)
dir.ldap.auth.password
Specifies the password for registering with the LDAP server.
String (0-64)
dir.ldap.auth.userId
Specifies the username for registering with LDAP server.
String (0-64)
dir.ldap.authType
Polycom, Inc.
17
Directory Parameters
Specifies the protocol for authenticating with the LDAP server.
ntlm (default) anonymous basic
dir.ldap.baseDN
Specifies the top level of the LDAP directory where searches begin.
To avoid LDAP registration issues, make sure the base DN is at least one level deeper than your domain. For example, set "ou=users,dc=example,dc=com" instead of
"dc=example,dc=com".
String (0-128)
${ldap_baseDN} - RealPresence Resource Manager accepts this value to automatically configure the parameter.
dir.ldap.bindDN
Specifies the bind DN when using basic authentication (i.e., dir.ldap.authType="basic").
String (0-128)
dir.ldap.defaultGroupDN
Specifies the top-level group of the LDAP directory required to access its hierarchical structure.
String (0-128)
${ldap_defaultgroupDN} - RealPresence Resource Manager accepts this value to automatically configure the parameter.
dir.ldap.server.address
Specifies the address of the LDAP directory server.
String (0-255)
${ldap_serveraddress} - RealPresence Resource Manager accepts this value to automatically configure the parameter.
dir.ldap.server.port
Specifies the port for connecting with the LDAP server.
Integer
389(default)
dir.ldap.useSSL
Encrypts data to and from the LDAP server when enabled.
1 (default)
0
dir.serverType
Specifies the type of directory service you want to register with. (Your system's local directory is always enabled.)
Off (default) - Use only the system's local directory.
LDAP - Register with an LDAP directory.
Polycom GDS - Register with the Polycom Global Directory Server (GDS).
Polycom, Inc.
18
Directory Parameters
dir.ldap.auth.useLoginCredentials
Specifies if you want to register with an LDAP directory using the same credentials you used for registering with a provisioning service.
With this parameter, provisioning separate username, password, and domain parameters for the directory service isn’t necessary.
0 (default)
1
Polycom, Inc.
19
Feature Activation Parameters
Topics:
▪
This section describes available feature activation configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Feature Activation Parameters
Use the following parameters to unlock certain features or the ability to update software on your G7500 system.
Note:
Software version 2.0 enables all available G7500 system features by default. With this version, you don’t need to enter a feature activation key.
For more information about feature activation and software update keys, see the
Polycom G7500
Administrator Guide
.
license.optionKey
Set this parameter with your system feature activation key.
String
license.softupdateKey
Set this parameter with your system software activation key.
String
Polycom, Inc.
20
General System Parameters
Topics:
▪
This section describes available configuration parameters for general system settings (for example, system name and time zone). Included are permitted values and, if applicable, guidance for configuring related parameters.
General System Parameters
Use the following parameters to configure general system settings on your G7500 system.
device.local.autoDaylightSavings.enable
When enabled, the system clock automatically adjusts for daylight saving time.
1 (default)
0
device.local.datetime.date.format
Specifies how the date displays.
mm_dd_yyyy (default) dd_mm_yyyy yyyy_mm_dd
device.local.datetime.time.24HourClock
Specifies how the time displays (12- or 24-hour format).
12_Hour (default)
24_Hour
device.local.deviceName
Specifies the system name.
String (1-40)
${device_name} - RealPresence Resource Manager accepts this value to automatically configure the parameter.
device.local.ntpServer.address.1
Specifies the address of the primary time server your system uses
Set this if device.local.ntpServer.mode="Manual".
String (0-255)
device.local.ntpServer.address.2
Specifies the address of the time server your system uses when the primary time server fails.
You can optionally set this if device.local.ntpServer.mode="Manual".
String (0-255)
Polycom, Inc.
21
General System Parameters
device.local.ntpServer.mode
Specifies if you want to automatically or manually configure the system to use a time server.
Auto (default) - Your system tries to automatically connect with a time server.
Manual - Set device.local.ntpServer.address.1 and optionally device.local.ntpServer.address.2.
Off - Set the current date and time in the system web interface.
device.local.timezone
Specifies the time difference between GMT and your location.
CST6CDT (default)
Etc/GMT+12
Pacific/Midway
Pacific/Honolulu
America/Adak
America/Anchorag
Pacific/Pitcairn
PST8PDT
BAJA
America/Phoenix
America/Mazatlan
MST7MDT
America/Guatemala
America/Monterrey
America/Regina
America/Lima
EST5EDT
America/Indianapolis
Canada/Atlantic
America/La//Paz
America/Caracas
America/Santiago
Canada/Newfoundland
America/Sao//Paulo
America/Cordoba
America/Godthab
America/Noronha
Atlantic/Azores
Atlantic/Cape//Verde
Etc/Greenwich
Polycom, Inc.
22
Africa/Casablanca
Europe/London
Europe/Amsterdam
Europe/Belgrade
Europe/Paris
Europe/Warsaw
Africa/Bangui
Europe/Athens
Europe/Bucharest
Europe/Sofia
Egypt
Europe/Tirane
Africa/Harare
Europe/Helsinki
Asia/Jerusalem
Asia/Baghdad
Asia/Kuwait
Europe/Moscow
Africa/Nairobi
Africa/Dar//es//Salaam
Iran
Asia/Muscat
Asia/Baku
Asia/Kabul
Indian/Kerguelen
Asia/Yekaterinburg
Asia/Karachi
Asia/Calcutta
Asia/Mumbai
Asia/Katmandu
Asia/Novosibirsk
Asia/Dhaka
Indian/Chagos
Asia/Colombo
Asia/Rangoon
Asia/Bangkok
Asia/Krasnoyarsk
Polycom, Inc.
General System Parameters
23
Asia/Hong//Kong
Asia/Ulaanbaatar
Asia/Singapore
Australia/Perth
Asia/Taipei
Japan
Asia/Seoul
Asia/Yakutsk
Australia/Adelaide
Australia/Darwin
Australia/Brisbane
Australia/Sydney
Pacific/Guam
Australia/Hobart
Asia/Vladivostok
Asia/Magadan
Pacific/Auckland
Pacific/Fiji
Pacific/Tongatapu
Note:
The Etc/GMT+12 value represents International Date Line West.
device.local.country
City where support is located.
String (0-64)
device.local.contact.country
Country where support is located.
String (0-64)
device.local.contact.email
Support email address.
String (0-64)
device.local.contact.fax
Support fax number.
String (0-64)
device.local.contact.person
Name of primary support contact.
String (0-64)
device.local.contact.phone
General System Parameters
Polycom, Inc.
24
Phone number of primary support contact.
String (0-64)
device.local.contact.state
State where support is located.
String (0-64)
device.local.contact.techSupport
Additional support contact.
String (0-64)
device.local.country
Country where your system is located.
United States (default)
Afghanistan
Albania
Algeria
American Samoa
Andorra
Angola
Anguilla
Antarctica
Antigua
Argentina
Armenia
Aruba
Ascension Islands
Australia
Australian Ext. Territories
Austria
Azerbaijan
Bahamas
Bahrain
Bangladesh
Barbados
Barbuda
Belarus
Belgium
Belize
Benin Republic
Polycom, Inc.
General System Parameters
25
Bermuda
Bhutan
Bolivia
Bosnia and Herzegovina
Botswana
Brazil
British Virgin Islands
British Indian Ocean Territory
Brunei
Bulgaria
Burkina Faso
Burma (Myanmar)
Burundi
Cambodia
Cameroon United Republic
Canada
Cape Verde Island
Cayman Islands
Central African Republic
Chad Republic
Chile
China
Christmas Island
Cocos Islands
Colombia
Comoros
Congo
Congo Democratic Republic
Cook Islands
Costa Rica
Croatia
Cuba
Curacao
Cyprus
Czech Republic
Denmark
Diego Garcia
Polycom, Inc.
General System Parameters
26
Djibouti
Dominica
Dominican Republic
Easter Island
East Timor
Ecuador
Egypt
El Salvador
Equatorial Guinea
Eritrea
Estonia
Ethiopia
Faeroe Islands
Falkland Islands
Fiji Islands
Finland
France
French Antilles
French Guiana
French Polynesia
French Southern and Antactic Lands
Gabon
Gambia
Georgia
Germany
Ghana
Gibraltar
Greece
Greenland
Grenada
Guadeloupe
Guam
Guantanamo Bay
Guatemala
Guinea
Guernsey
Guinea-Bissau
Polycom, Inc.
General System Parameters
27
Israel
Italy
Ivory Coast
Jamaica
Japan
Jersey
Jordan
Kazakhstan
Kenya
Kiribati
Korea North
Korea South
Kosovo
Kuwait
Kyrgyzstan
Laos
Latvia
Lebanon
Lesotho
Liberia
Libya
Guyana
Haiti
Honduras
Hong Kong
Hungary
Iceland
India
Indonesia
Inmarsat (Atlantic Ocen West)
Inmarsat (Atlantic Ocen East)
Inmarsat (Indian Ocean)
Inmarsat (Pacific Ocean)
Inmarsat (SNAC)
Iran
Iraq
Ireland
Polycom, Inc.
General System Parameters
28
Liechtenstein
Lithuania
Luxembourg
Macao
Macedonia
Madagascar
Malawi
Malaysia
Maldives
Mali
Malta
Man, Isle of
Mariana Islands
Marshall Islands
Martinique
Mauritania
Mauritius
Mayotte Island
Mexico
Micronesia
Midway Island
Moldova
Monaco
Mongolia
Montenegro
Montserrat
Morocco
Mozambique
Myanmar (Burma)
Namibia
Nauru
Nepal
Netherlands
Netherlands Antillies
Nevis
New Caledonia
New Zealand
Polycom, Inc.
General System Parameters
29
Nicaragua
Niger
Nigeria
Niue
Norfolk Island
Norway
Oman
Pakistan
Palau
Palestine
Panama
Papua New Guinea
Paraguay
Peru
Philippines
Pitcairn
Poland
Portugal
Puerto Rico
Qatar
Reunion Island
Romania
Russia
Rwanda
St Helena
St Kitts
St Lucia
St Pierre and Miquelon
St Vincent
San Marino
Sao Tome and Principe
Saudi Arabia
Senegal
Serbia
Seychelles
Sierra Leone
Singapore
Polycom, Inc.
General System Parameters
30
Slovakia
Slovenia
Solomon Islands
Somalia Republic
South Africa
Spain
Sri Lanka
Sudan
Suriname
Swaziland
Sweden
Switzerland
Syria
Taiwan
Tajikistan
Tanzania
Thailand
Togo
Tonga
Trinidad and Tobago
Tunisia
Turkey
Turkmenistan
Turks and Caicos
Tuvalu
Uganda
Ukraine
United Arab Emirates
United Kingdom
Uruguay
US Minor Outlying Islands
US Virgin Islands
Uzbekistan
Vanuatu
Vatican City
Venezuela
Vietnam
Polycom, Inc.
General System Parameters
31
General System Parameters
Wake Island
Wallis And Futuna Islands
Western Samoa
Yemen
Zambia
Zanzibar
Zimbabwe
device.local.language
Sets the language displayed on the system.
ENGLISHUS (default)
ARABIC
ENGLISHUK
GERMAN
SPANISH
FRENCH
ITALIAN
JAPANESE
KOREAN
HUNGARIAN
NORWEGIAN
POLISH
PORTUGUESE
RUSSIAN
CHINESE
CHINESET
device.local.roomName
Specifies the room where your system resides.
The room name displays on the screens of call participants.
String (1-40)
G7500 (default)
device.remoteControl.audioConfirm
Specifies whether to play a voice confirmation of numbers selected with the remote control or keypad.
1 (default)
0
device.remoteControl.numKeypadInCall
Specifies whether pressing number buttons on the remote control or keypad moves the camera to presets or generates touch tones (DTMF tones).
Polycom, Inc.
32
General System Parameters
If set to "Presets", you can generate DTMF tones by pressing the # key on the remote control while on a video screen.
Presets (default)
Tones
device.remoteControl.poundButtonFunction
Specifies the behavior of the # button on the remote control.
pound_then_at (default) - Pressing the # button once displays the hash symbol. Pressing the # button twice quickly displays the @ symbol.
at_then_pound - Pressing the # button once displays the @ symbol. Pressing the # button twice quickly displays the # symbol.
device.remoteControl.starButtonFunction
Specifies the behavior of the * button on the remote control.
period_then_star (default) - Pressing the * button once displays the * symbol. Pressing the * button twice quickly displays a period.
star_then_period - Pressing the * button once displays a period. Pressing the * button twice quickly displays the * symbol.
device.screenSaver.mode
Specifies if you want to display a black screen or no signal message when your system goes to sleep.
NoSignal (default)
Black
device.sleepTimeout
Specifies how many minutes the device can be idle before it goes to sleep.
0 (default)
1
3
15
30
45
60
120
240
480
Polycom, Inc.
33
Local Interface Parameters
Topics:
▪
This section describes available local interface configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Local Interface Parameters
Use the following parameters to configure local interface settings on your G7500 system.
homeScreen.addressBar.primary
Specifies the main element that displays on the home screen address bar.
Primary IP Address (default)
Guest Wi-Fi IP Address
SIP Address
H.323 Extension
None
homeScreen.addressBar.secondary
Specifies the secondary element that displays on the home screen address bar.
SIP Address (default)
Primary IP Address
Guest Wi-Fi IP Address
H.323 Extension
None
homeScreen.backgroundImage
Specify a background image for the home screen.
String
The image must have a 16:9 resolution between 1280x720 and 3840x2160 (Polycom recommends 1920x1080, 2560x1440, or 3840x2160). JPEG and PNG formats with a file size of less than 10 MB are supported.
The path to the image must be absolute; relative paths do not work.
homeScreen.topWidgetType
Determines if meeting information or favorite contacts display on the local interface home screen. You also can hide this information by setting "none".
calendar (default) favorites none
Polycom, Inc.
34
Logging Parameters
Topics:
▪
This section describes available logging configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Logging Parameters
Use the following parameters to configure logging settings for your G7500 system.
device.syslog.autoTransfer.customFolderName
Lets you specify a folder name for manual log transfers.
Set if you configured device.syslog.autoTransfer.folderNameOption="Custom".
String (0-64)
Log_archive (default)
device.syslog.autoTransfer.folderNameOption
Specifies the folder name for log transfers.
SystemNameAndTimestamp (default) - Folder name is the system name and the timestamp of the log transfer. For example, if the system name is Marketing, the folder name might be marketing_<date_and_time>.
Timestamp - Folder name is the timestamp of the log transfer (e.g., <yyyyMMddhhmmssSSS>).
Custom - Lets you specify a folder name for manual log transfers. Set device.syslog.autoTransfer.customFolderName.
device.syslog.autoTransfer.frequency
Specifies when logs are transferred.
Manual (default) - The transfer starts when you select the Start Log Transfer button, which is visible only on the local interface. If the log fills before being transferred, new events overwrite the oldest events.
AutoAtThreshold - The transfer starts automatically when the limit set for device.syslog.autoTransfer.threshold is reached.
device.syslog.autoTransfer.threshold
Reaching the log storage threshold percentage you configure here creates a log entry and automatically transfers logs to an external storage device if device.syslog.autoTransfer.frequency="AutoAtThreshold".
Off (default)
90
80
70
60
Polycom, Inc.
35
Logging Parameters
50
40
30
20
10
device.syslog.enable
Specifies whether remote logging is enabled. Enabling this causes the system to send each log message to the specified server in addition to logging it locally.
Remote logging encryption is supported using TLS. If you're using UDP or TCP transport,
Polycom recommends remote logging only on secure, local networks.
0 (default)
1
device.syslog.level
Sets the minimum log level of messages stored in the system's flash memory. The level is the same for local and remote logging.
"Debug" logs all messages, while "Warning" logs the fewest number of messages.
It's recommended you use the default value.
Debug (default)
Info
Warning
Error
Critical
device.syslog.serverName
Specifies the server address and port. If the port isn't specified, a default destination port is used. The default port is determined by how device.syslog.transport is configured:
UDP: 514
TCP: 601
TLS: 6514
The address and port can be specified in the following formats:
IPv4 address: 192.0.2.0:<port>, where <port> is the elective destination port number in the
1-65535 range.
FQDN: logserverhost.company.com:<port>, where <por> is the elective destination port number in the 1-65535 range.
String
device.syslog.transport
Specifies the transport protocol for sending logs to a remote server.
UDP (default)
TCP
TLS
Polycom, Inc.
36
log.feature.h323Trace.enable
If set to "1", your system logs additional H.323 connectivity information.
0 (default)
1
log.feature.h323Trace.enable
If set to "1", your system logs additional SIP connectivity information.
0 (default)
1
Logging Parameters
Polycom, Inc.
37
Microsoft Exchange Server Parameters
Topics:
▪
Using Provisioning Service Credentials to Register with a Calendaring Service
▪
Microsoft Exchange Server Parameters
You can integrate with Microsoft Exchange Server so your G7500 system can display calendar details linked to an Outlook or Office 365 account.
This section describes available Microsoft Exchange Server configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Using Provisioning Service Credentials to Register with a Calendaring Service
You can register your G7500 system with a calendaring service using the same credentials you used to register with your provisioning service.
To do this, set exchange.auth.useLoginCredentials=”1”
.
With this parameter, provisioning separate username, password, and domain parameters for the calendaring service isn’t necessary. For example, if you set exchange.auth.useLoginCredentials=”1”
, you don’t have to set exchange.auth.userName, exchange.auth.password, and exchange.auth.domain.
Microsoft Exchange Server Parameters
Use the following parameters to integrate your G7500 system with Microsoft Exchange Server.
exchange.auth.domain
Specifies the domain for registering to the Microsoft Exchange Server in NETBIOS or DNS notation (e.g., company.local or COMPANY).
String
exchange.auth.domain
Specifies the email address used when scheduling the system for a meeting (for instance, you could use your system as a mechanism for reserving a meeting space). This should match the
Primary SMTP Address for the account on Microsoft Exchange Server, which displays as the value of the mail attribute in the account properties.
String
exchange.auth.password
Specifies the system password for registering with the Microsoft Exchange Server. This can be the system password or an individual's password.
If you want the calendaring service to use the calendar associated with an Office 365 account, enter the password for that account here.
Polycom, Inc.
38
Microsoft Exchange Server Parameters
String
exchange.auth.userName
Specifies the user name for registering to the Microsoft Exchange Server with no domain information included. This can be the system name or an individual's name (e.g., [email protected]).
If you want the calendaring service to use the calendar associated with an Office 365 account, enter the user name for that account here.
String (0-64)
exchange.enable
Enables or disables the ability to register with a calendaring service.
0 (default)
1
exchange.meeting.reminderInterval
Specifies the number of minutes before the meeting that a reminder displays on the system.
5 (default)
None
1
10
15
30
exchange.meeting.reminderSound.enable
Specifies whether to play a sound along with the text reminder (when the system is not in a call).
1 (default)
0
exchange.server.url
Specifies the Fully Qualified Domain Name (FQDN) of the Microsoft Exchange Client Access server. If your organization has multiple servers behind a network load balancer, this is the
FQDN of the server's virtual IP address. If required, an IP address can be used instead of an
FQDN, but Polycom recommends using the same FQDN for Outlook clients.
String
exchange.showPrivateMeeting
Specifies whether to display details about meetings marked private.
0 (default)
1
exchange.auth.useLoginCredentials
Specifies if you want to register with a calendaring service using the same credentials you used for registering with a provisioning service.
With this parameter, provisioning separate username, password, and domain parameters for the calendaring service isn’t necessary.
0 (default)
Polycom, Inc.
39
1
Microsoft Exchange Server Parameters
Polycom, Inc.
40
Network Parameters
Topics:
▪
Provisioning Basic Wired LAN Properties
▪
Provisioning Basic Wi-Fi Properties
▪
This section describes available network configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Provisioning Basic Wired LAN Properties
You can provision your G7500 system to automatically obtain some wired LAN properties—including IP address, subnet mask, default gateway, and DNS server(s)—by setting device.net.mode=“Automatically”
.
These LAN properties can also be provisioned individually by setting device.net.mode=“Manually”
.
In this situation, you must set all of the following additional parameters or no LAN properties will provision successfully:
▪ device.net.ipAddress
▪ device.net.subnetMask
▪ device.net.ipGateway
Note:
Setting device.net.dns.server.* parameters is optional when device.net.mode=“Manually”
.
When your system obtains these LAN properties automatically, you can’t then overwrite individual properties by setting device.net.ipAddress=“192.0.2.255”
, for example.
When provisioning a new IP address for your system, active sessions through the system web interface don’t automatically refresh. You must enter the new IP address in your browser to re-establish access.
Provisioning Basic Wi-Fi Properties
You can provision your G7500 system to automatically obtain some Wi-Fi properties—including IP address, subnet mask, default gateway, and DNS server(s)—by setting device.net.secondaryNetwork.mode=“Automatically”
.
These Wi-Fi properties can also be provisioned individually by setting device.net.secondaryNetwork.mode=“Manually”
. In this situation, you must set all of the following additional parameters or no Wi-Fi properties will provision successfully:
▪ device.net.secondaryNetwork.ipAddress
▪ device.net.secondaryNetwork.subnetMask
▪ device.net.secondaryNetwork.ipGateway
Polycom, Inc.
41
Network Parameters
Note:
Setting device.net.secondaryNetwork.dns.server.* parameters is optional when device.net.secondaryNetwork.mode=“Manually”
.
When your system obtains these Wi-Fi properties automatically, you can’t then overwrite individual properties by setting device.net.secondaryNetwork.ipAddress=“192.0.2.255”
, for example.
When provisioning a new IP address for your system, active sessions through the system web interface don’t automatically refresh. You must enter the new IP address in your browser to re-establish access.
Remember, to successfully provision any Wi-Fi setting, you must set device.net.secondaryNetwork.type=“WiFi”
.
Network Parameters
Use the following parameters to configure some network settings for your G7500 system.
device.net.dns.server.1
If the system does not automatically obtain a DNS server address on the wired LAN, enter one here.
String
device.net.dns.server.2
(Optional) If the system does not automatically obtain a DNS server address on the wired LAN, enter one here.
String
device.net.dns.server.3
(Optional) If the system does not automatically obtain a DNS server address on the wired LAN, enter one here.
String
device.net.dns.server.4
(Optional) If the system does not automatically obtain a DNS server address on the wired LAN, enter one here.
String
device.net.ipAddress
Specifies the system IPv4 address on the wired LAN.
You don't need to set this if device.net.mode="Automatically".
String
0.0.0.0
device.net.ipGateway
Specifies the IP gateway on the wired LAN.
You don't need to set this if device.net.mode="Automatically".
String
0.0.0.0
Polycom, Inc.
42
Network Parameters
device.net.mode
Specifies how you want to configure your system IPv4 address on the wired LAN.
If set to "Automatically", make sure you have a DHCP server in your environment.
Automatically (default)
Manually
device.wifi.enable
Enables or disables Wi-Fi wireless comminication on your system.
Setting to "0" turns off screen mirroring with Miracast-certified devices and prevents the system from using Wi-Fi to connect to a secondary network.
1 (default)
0
device.net.secondaryNetwork.type
Specifies if you want your system to connect to a secondary network over Wi-Fi for additional access (e.g., guest users).
None (default)
WiFi
device.net.secondaryNetwork.wifi.ssid
Specifies the Wi-Fi network name.
String (0-32)
device.net.secondaryNetwork.wifi.securityType
Specifies the Wi-Fi network encryption protocol.
WPA_PSK (default)
None
WEP
802_1xEAP
device.net.secondaryNetwork.wifi.WEP.key
Specifies the WEP key.
You should set this if device.net.secondaryNetwork.wifi.securityType="WEP".
1 (default)
0
device.net.secondaryNetwork.wifi.dot1xEAP.method
Specifies the extensible authentication protocol (EAP) for WPA-Enterprise (802.1xEAP).
You should set this if device.net.secondaryNetwork.wifi.securityType="802_1xEAP".
PEAP (default)
TLS
TTLS
PWD
device.net.secondaryNetwork.wifi.dot1xEAP.phase2Auth
Polycom, Inc.
43
Network Parameters
Specifies the Phase 2 authentication method.
You should set this if device.net.secondaryNetwork.wifi.securityType="802_1xEAP".
NONE (default)
MSCHAPV2
GTC
device.net.secondaryNetwork.wifi.WPA.password
Specifies an encryption passphrase (like a password) for the Wi-Fi network. You must enter the passphrase to connect to the Wi-Fi network.
You should set this if device.net.secondaryNetwork.wifi.securityType="WPA_PSK".
String
device.net.secondaryNetwork.wifi.dot1xEAP.identity
Specifies the login username for WPA-Enterprise (802.1xEAP).
You should set this if device.net.secondaryNetwork.wifi.securityType="802_1xEAP".
String
device.net.secondaryNetwork.wifi.dot1xEAP.password
Specifies the login password for WPA-Enterprise (802.1xEAP).
You should set this if device.net.secondaryNetwork.wifi.securityType="802_1xEAP".
String
device.net.secondaryNetwork.dns.server.1
Specifics the DNS server address on the Wi-Fi network.
String
device.net.secondaryNetwork.dns.server.2
Specifics the alternate DNS server address on the Wi-Fi network.
String
device.net.secondaryNetwork.ipAddress
Specifies the system IPv4 address on the Wi-Fi network.
String
0.0.0.0
device.net.secondaryNetwork.ipGateway
Specifies the IP gateway for the Wi-Fi network.
String
0.0.0.0
device.net.secondaryNetwork.mode
Specifies how you want to configure your system Wi-Fi network IP address.
If you set "Automatically", make sure you have a DHCP server in your environment.
Automatically (default)
Manually
Polycom, Inc.
44
Network Parameters
device.net.secondaryNetwork.subnetMask
Specifies the subnet mask address for the Wi-Fi network.
String
255.255.255.0
device.net.subnetMask
Specifies the subnet mask address for the wired LAN.
You don't need to set this if device.net.mode="Automatically".
String
255.255.255.0
device.net.domain
Identifies the domain your system belongs to.
Set this if the system does not automatically obtain a domain name.
String
device.net.dot1x.enable
Specifies whether EAP/802.1X network access is enabled. The following authentication protocols are supported:
EAP-MD5
EAP-PEAPv0 (MSCHAPv2)
EAP-TTLS
EAP-TLS
0 (default)
1
device.net.dot1x.identity
Specifies the system's identity used for 802.1X authentication.
String (0-64)
device.net.dot1x.password
Specifies the system's password used for 802.1X authentication. This setting is required when
EAP-MD5, EAP-PEAPv0, or EAP-TTLS is used.
String
device.net.echo.enable
When enabled, your system sends an ICMP Echo Reply message in response to a broadcast or multicast Echo Request that isn't specifically addressed to the system.
0 (default)
1
device.net.ethernet.autoNegotiation
Specifies whether the system should automatically negotiate the LAN speed and duplex mode per IEEE 802.3 autonegotiation procedures.
Polycom recommends that you use autonegotiation to avoid network issues.
Polycom, Inc.
45
Network Parameters
If enabled, you don't have to set device.net.ethernet.portSpeed or device.net.ethernet.duplexMode.
1 (default)
0
device.net.ethernet.duplexMode
Specifies the duplex mode to use. Note that the speed you choose must be supported by the switch.
You don't need to set this if device.net.ethernet.autoNegotiation="1".
Half (default)
Full
device.net.ethernet.portSpeed
Specifies the wired LAN speed to use. Note that the speed you choose must be supported by the switch.
You don't need to set this if device.net.ethernet.autoNegotiation="1".
10Mbps
100Mbps (default)
1000Mbps
device.net.hostName
Indicates your system name. If the system discovers a valid name during setup or a software installation, the host name is automatically created. However, if an invalid system name is found, such as a name with a space, the system creates a host name using the following format:
SystemType-xxxxxx, where xxxxxx is a set of random alphanumeric characters.
IPv4 networks: The system sends the host name to the DHCP server to attempt to register the name with the local DNS server or look up the domain where the system is registered (if supported).
String (0-36) roomseries
device.net.icmp.txRateLimit
Specifies the minimum number of milliseconds between transmitted packets.
The default value of 1000 means the system sends 1 packet per second. If you enter 0, the transmission rate limit is disabled.
This setting applies only to "error" ICMP packets. This setting has no effect on "informational"
ICMP packets, such as echo requests and replies.
Integer (0-60000)
1000
device.net.ignoreRedirect
Enables the system to ignore ICMP redirect messages.
Polycom recommends you enable this setting in most circumstances.
1 (default)
0
Polycom, Inc.
46
Network Parameters
device.net.lldp.enable
Specifies if you want the system to advertise itself on the network using the Link Layer
Discovery Protocol (LLDP).
Set to "1" if you want your system to operate on a virtual LAN (VLAN).
If set to "1", system.network.wired.vlan.enabled and system.network.wired.vlan.vlanid should be automatically configured.
0 (default)
1
device.net.unreachableTx.enable
Generates an ICMP Destination Unreachable message if a packet cannot be delivered to its destination for reasons other than network congestion.
1 (default)
0
device.net.vlan.audioPriority
Sets the link layer priority of audio traffic on the wired LAN. Audio traffic is RTP traffic consisting of audio data and associated RTCP traffic.
Setting "6" or "7" isn't recommended.
To use this parameter, you should set device.net.lldp.enable="1".
0 (default)
1
4
5
2
3
6
7
device.net.vlan.controlPriority
Sets the link layer priority of control traffic on the wired LAN. Control traffic is consists of control information associated with a call:
H.323: H.225.0 Call Signaling, H.225.0 RAS, H.245, Far-End Camera Control (FECC)
3
4
1
2
5
SIP: SIP Signaling, FECC, Binary Floor Control Protocol (BFCP)
Setting "6" or "7" isn't recommended.
To use this parameter, you should set device.net.lldp.enable="1".
0 (default)
Polycom, Inc.
47
Network Parameters
6
7
device.net.vlan.enable
Enable if you want to configure your system with a virtual LAN (VLAN) and and set link layer priorities.
0 (default)
1
device.net.vlan.videoPriority
Sets the link layer priority of video traffic on the wired LAN. Video traffic is RTP traffic consisting of video data and associated RTCP traffic.
Setting "6" or "7" isn't recommended.
To use this parameter, you should set device.net.lldp.enable="1".
0 (default)
1
4
5
2
3
6
7
device.net.vlanid
Identifies the VLAN you want your system to operate on.
To use this parameter, you should set device.net.vlan.enable="1".
Integer (1-4095)
1
net.firewall.fixedPorts.enable
If enabled, you can define which TCP and UDP ports your system uses for firewall traversal.
Enable if your firewall isn't H.323 compatible. Disable if your firewall is H.323 compatible or the system isn't behind a firewall.
0 (default)
1
Note:
For the fixed ports you configure, you must open the corresponding ports on your firewall. For H.323, open TCP port 1720. For SIP, open UDP port 5060,
TCP 5060, or TCP 5061 depending on if you're using UDP, TCP, or TLS, respectively, as the SIP transport protocol.
net.firewall.fixedPorts.tcpStart
The starting value for the range of TCP ports used by the system. The system automatically configures the range based on the beginning value you set here.
Polycom, Inc.
48
Network Parameters
The system assigns a port range starting with the TCP and UDP ports you specify (port 3230 is where the range begins by default).
To allow H.323 traffic, you need two TCP and eight UDP ports per connection. You must also open TCP port 1720 on the firewall.
To allow SIP traffic, you need TCP port 5060 and eight UDP ports per connection.
Fixed ports range and filters: You might notice that the source port of a SIP signaling message is not in the fixed ports range. When your firewall is filtering on source ports, in the system web interface, set voIpProt.SIP.forceConnectionReuse="1". When enabled, the system uses port
5060 and 5061 for the source and destination port (these must be open on the firewall).
Integer (1024-65522)
3230 (default)
net.firewall.fixedPorts.udpStart
The starting value for the range of UDP ports used by the system. The system automatically configures the range based on the beginning value you set here.
To allow H.323 traffic, you need two TCP and eight UDP ports per connection. You must also open TCP port 1720 on the firewall.
To allow SIP traffic, you need TCP port 5060 and eight UDP ports per connection.
Because systems support ICE, the range of fixed UDP ports is 32. The system cycles through the available ports from call to call.
Fixed ports range and filters: You might notice that the source port of a SIP signaling message is not in the fixed ports range. When your firewall is filtering on source ports, in the system web interface, set voIpProt.SIP.forceConnectionReuse="1". When enabled, the system uses port
5060 and 5061 for the source and destination port (these must be open on the firewall).
Integer (1024-65424)
3230 (default)
net.firewall.h460.enable
Allows the system to be configured for H.460 firewall/NAT traversal.
0 (default)
1
net.firewall.nat.gabAddressDisplayed
Sets whether to display the system's public or private address in the global directory.
To use this parameter, make sure net.firewall.nat.useNatAddress is set to "Auto" or "Manual".
Public (default)
Private
net.firewall.nat.h323Compatible
Identifies whether the system is behind a NAT that can translate H.323 traffic.
To use this parameter, make sure net.firewall.nat.useNatAddress is set to "Auto" or "Manual".
0 (default)
1
net.firewall.nat.publicAddress
Polycom, Inc.
49
Network Parameters
The address callers from outside the LAN use to call your system. If you configured the NAT manually (net.firewall.nat.useNatAddress="Manual"), set the NAT public address here.
String (0-255)
0.0.0.0 (default)
net.firewall.nat.useNatAddress
Specifies if the system should automatically determine the NAT public (WAN) address.
If the system is not behind a NAT or is connected to the network through a VPN, set to "Off".
If the system is behind a NAT that allows HTTP traffic, set to "Auto".
If the system is behind a NAT that does not allow HTTP traffic, set to "Manual".
Off (default)
Auto
Manual
net.proxy.address
The web proxy address.
Set this parameter if net.proxy.autoconf="0".
String (0-1024)
net.proxy.autoconf
Set to "1" for the following web proxy configuration methods:
Automatic: Your system obtains a URL for downloading a proxy auto-configuration (PAC) file through DHCP option 252. With this method, you may have to also set proxy credentials.
Semi-automatic: You specify the proxy credentials and URL for automatically downloading a
PAC file.
Set to "0" for manual configuration. You must then specify the proxy address, port, and credentials. This method lets you configure your system with only one proxy.
1 (default)
0
net.proxy.pacfile.url
The address from which your system downloads the PAC file.
String (0-1024)
net.proxy.port
The web proxy port.
Set this parameter if net.proxy.autoconf="0".
Integer (1-65535)
8080 (default)
net.proxy.webproxy.auth.password
The password for connecting your system with the web proxy.
String
Polycom, Inc.
50
Network Parameters
Note:
Credentials may not be needed if your system is automatically configured with a proxy.
net.proxy.webproxy.auth.userName
The username for connecting your system with the web proxy.
String (0-64)
Note:
Credentials may not be needed if your system is automatically configured with a proxy.
net.proxy.webproxy.blockBasicAuth
Specifies if you want to allow your system to use basic authentication (disabled by default) when connecting with a web proxy.
1 (default)
0
net.proxy.webproxy.enable
Enable to allow your system to be configured with web proxies.
0 (default)
1
net.proxy.wpad.enable
Set to "1" if net.proxy.autoconf="1" and you prefer the automatic web proxy configuration method. Enabling the web proxy auto-discovery protocol (WPAD) helps your system automatically download the PAC file on your network using DHCP option 252.
Set to "0" if you prefer semi-automatic web proxy configuration, where you specify the proxy credentials and URL for automatically downloading a PAC file.
1 (default)
0
Polycom, Inc.
51
Peripheral Device Parameters
Topics:
▪
Peripheral Device Pairing Parameters
▪
▪
This section describes available peripheral device configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
These parameters apply to the following peripheral devices:
▪ Polycom IP Table Microphone
▪ Polycom IP Ceiling Microphone
▪ Polycom Microphone IP Adapter
Peripheral Device Pairing Parameters
Use the following parameter to automatically pair some peripheral devices with your G7500 system.
mr.primary.autoPair.enable
Enables your system to automatically pair with some peripheral devices, such as a Polycom IP
Table Microphone.
For example, if mr.primary.autoPair.enable="1" and you connect a table microphone to a LAN port on your system, it should automatically pair and be ready to use.
1
0
IP Microphone Parameters
Use the following parameters to configure Polycom IP Table Microphones and Polycom IP Ceiling
Microphones connected to your system.
log.level.change.xxx
Controls the logging detail level. These are the input filters into the internal memory-based log system.
Possible values for xxx are cfg, curl, mr, so, ss, ssps, and usb.
0-6 (default is 4)
log.render.level
Controls the logging level for the lowest severity of events to log in the syslog.
For example, when you choose a log level 0 or 1 - Severity Debug (7), the log includes all events of an equal or greater severity level 0, this excludes events of a lower severity level 1.
2 or 3 - Severity Informational (6)
Polycom, Inc.
52
Peripheral Device Parameters
4 Severity Error (3)
5 Severity Critical (2)
6 Severity Emergency (0)
0-6 (default is 1)
log.render.stdout
Enables or disables the logs print to standard out (serial and shell terminal).
0-1 (default is 0)
mr.pair.tls.enabled
Enables or disables TLS between paired devices.
0-1 (default is 1)
device.net.mikoTimeout.set
Allows you to set the device.net.mikoTime parameter.
0-1 (default is 0)
device.net.mikoTimeout
Timeout value for table microphone DHCP in seconds.
30-60 (default is 30)
feature.usbdevice.enable
Enables or disables USB device access.
0-1 (default is 1)
Microphone Adapter Parameters
Use the following parameters to configure the Polycom Microphone IP Adapter to your system.
device.syslog.renderLevel
Controls the logging details level.
Debug (default)
Info
Warning
Error
Critical
call.encryption.requireAES
Controls when to use the audio encryption.
Off
When_Available (default)
Required_Video
Required_All
sec.TLS.disableVersion1
Enables or disables TLS1.0.
Polycom, Inc.
53
True
False (default)
device.local.deviceName
The name of your system.
String
Peripheral Device Parameters
Polycom, Inc.
54
Provisioning Parameters
Topics:
▪
This section describes available configuration parameters for your provisioning setup. Included are permitted values and, if applicable, guidance for configuring related parameters.
Provisioning Parameters
Use the following parameters to configure provisioning settings on your G7500 system.
prov.polling.period
Specifies your system's provisioning polling interval in seconds.
For example, if you set this parameter to "120", your system is provisioned every two minutes.
Integer >= 60
prov.heartbeat.interval
Specifies how often (in seconds) your system indicates it's available to the provisioning server.
This feature runs in the background and does not affect user experience.
Integer (120-600)
600 (default)
prov.softupdate.https.enable
Specifies whether your system gets software updates via HTTP or HTTPS.
0 (default) - Your system gets software updates via HTTP.
1 - Your system gets software updates via HTTPS.
Note:
If you are using private PKI certificates in your environment and want HTTPS downloads to work, you must install the trusted root certificate from your internal certificate authority (CA) on the system using one of the sec.TLS.customCaCert.* parameters.
Polycom, Inc.
55
Quality of Service Parameters
Topics:
▪
This section describes available quality of service (QoS) configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Quality of Service Parameters
Use the following parameters to configure QoS settings on your G7500 system.
qos.tosType
Specifies the type of service (ToS), which lets you prioritize packets sent to your system for video, audio, Far End Camera Control (FECC), and OA&M
IP_Precedence (default) - Uses a priority level between 0 and 7.
DiffServ - Uses a priority level between 0 and 63.
qos.diffServ.audio
Specifies the DiffServ priority level for audio RTP and associated RTCP traffic.
Integer (0-63)
0 (default)
qos.diffServ.video
Specifies the DiffServ priority level for video RTP and associated RTCP traffic.
Integer (0-63)
0 (default)
qos.diffServ.fecc
Specifies the DiffServ priority level for control traffic on the following channels:
H.323: H.225.0 Call Signaling, H.225.0 RAS, H.245, and FECC.
SIP: SIP Signaling, FECC, and Binary Floor Control Protocol (BFCP).
Integer (0-63)
40 (default)
Note:
FECC is enabled by video.camera.farControlNearCamera.
qos.diffServ.oam
Specifies the DiffServ value for traffic unrelated to video, audio, or FECC.
Integer (0-63)
16 (default)
qos.dynamicBandwidth.enable
Polycom, Inc.
56
Quality of Service Parameters
Enable if you want the system to automatically determine the optimal call rate.
1 (default)
0
qos.intServ.audio
Specifies the IP Precedence priority level for audio RTP and associated RTCP traffic.
Integer (0-7)
5 (default)
qos.intServ.fecc
Specifies the IP Precedence priority level for control traffic on the following channels:
H.323: H.225.0 Call Signaling, H.225.0 RAS, H.245, and FECC.
SIP: SIP Signaling, FECC, and Binary Floor Control Protocol (BFCP).
Integer (0-7)
3 (default)
Note:
FECC is enabled by video.camera.farControlNearCamera.
qos.intServ.oam
Specifies the IP Precedence value for traffic unrelated to video, audio, or FECC.
Integer (0-7)
0 (default)
qos.intServ.video
Specifies the IP Precedence priority level for video RTP and associated RTCP traffic.
Integer (0-7)
4 (default)
qos.LPR.enable
If enabled, the system uses the Lost Packet Recovery (LPR) protocol to help compensate for packet loss if it occurs.
1 (default)
0
qos.maxRxBandwidth
Specifies the maximum receive call rate between 64 kbps and the system's maximum line rate.
This can be useful when the system is connected to the network using an access method with different transmit and receive bandwidth.
6144 (default)
64
128
192
256
320
Polycom, Inc.
57
Quality of Service Parameters
896
960
1024
1088
1152
1216
1280
1344
640
704
768
832
384
448
512
576
1408
1472
1536
1600
1664
1728
1792
1856
1920
2048
3840
4096
qos.maxTxBandwidth
Specifies the maximum receive call rate between 64 kbps and the system's maximum line rate.
This can be useful when the system is connected to the network using an access method with different transmit and receive bandwidth.
6144 (default)
64
128
192
256
Polycom, Inc.
58
Quality of Service Parameters
832
896
960
1024
1088
1152
1216
1280
576
640
704
768
320
384
448
512
1344
1408
1472
1536
1600
1664
1728
1792
1856
1920
2048
3840
4096
qos.mtuMode
Determines whether to use the default Maximum Transmission Unit (MTU) size for calls or let you specify it.
Default (default)
Specify
qos.mtuSize
Specifies the MTU size (in bytes) used in calls.
Decrease the MTU if video quality is poor or network errors occur (packets might be too large).
Polycom, Inc.
59
Quality of Service Parameters
Increase the MTU if the network is burdened with unnecessary overhead (packets might be too small).
1260 (default)
660
780
900
1020
1140
1500
qos.rsvp.enable
If enabled, the system can use the Resource Reservation Setup Protocol (RSVP) to request that routers reserve bandwidth along an IP connection path. (To use this feature, the near and far site must support RSVP.)
1 (default)
0
Polycom, Inc.
60
Security Parameters
Topics:
▪
Provisioning Updated PKI Certificates and CRLs
▪
This section describes available security configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Provisioning Updated PKI Certificates and CRLs
During provisioning, your G7500 system checks if a new public key infrastructure (PKI) certificate is just an updated version of an installed certificate.
If the certificate contents have changed since it was last successfully provisioned or manually installed
(e.g., there’s a new expiration date), the new certificate is applied and the older one is deleted. If the certificate hasn’t changed, the new certificate is ignored.
This is not the case with certificate revocation lists (CRLs), which are replaced each time your system is provisioned even if the CRL hasn’t changed.
Security Parameters
Use the following parameters to configure security settings on your G7500 system.
sec.access.maxSessions
Sets the maximum number of connected sessions through the system web interface and command-line API (SSH or telnet).
50 (default)
45
40
35
30
25
20
15
10
sec.access.room.accessSettings.enable
Specifies whether the User Settings screen is accessible through the local interface.
0 (default)
1
sec.auth.portLockout.failedLoginWindow
Polycom, Inc.
61
Security Parameters
4
5
2
3
6
7
8
9
10
11
6
7
4
5
Specifies the number of hours, starting with the first failed login attempt, during which subsequent failed login attempts are counted against the maximum number allowed
(sec.auth.portLockout.lockoutAttempts).
The counter resets when the set period of time expires or a user successfully logs in.
2
3
Off (default)
1
16
17
18
19
12
13
14
15
20
21
22
23
24
sec.auth.portLockout.lockoutAttempts
The number of failed login attempts allowed before the web interface locks.
Off (default)
Polycom, Inc.
62
Security Parameters
20
30
60
120
2
3
5
10
8
9
10
sec.auth.portLockout.lockoutTime
Specifies the number of minutes that the web interface remains locked due to failed login attempts. When this period expires, the failed login attempts counter resets and you can try to log in again.
1 (default)
240
480
sec.auth.portLockout.ssh.failedLoginWindow
Specifies the number of hours, starting with the first failed login attempt, during which subsequent failed login attempts are counted against the maximum number allowed
(sec.auth.portLockout.ssh.lockoutAttempts).
11
12
13
14
7
8
9
10
5
6
3
4
The counter resets when the set period of time expires or a user successfully logs in.
Off
1 (default)
2
Polycom, Inc.
63
Security Parameters
19
20
21
22
15
16
17
18
23
24
sec.auth.portLockout.ssh.lockoutAttempts
Specifies the number of failed login attempts allowed before SSH access to the API locks.
Off
2
3 (default)
4
7
8
5
6
9
10
sec.auth.portLockout.ssh.lockoutTime
Specifies the amount of time that SSH access to the API remains locked due to failed login attempts. When this period expires, the failed login attempts counter resets and you can try to log in again.
10
20
30
60
3
5
1 (default)
2
120
240
480
sec.nids.enable
Polycom, Inc.
64
Security Parameters
When set to "1", the system creates security log entries when it detects a possible network intrusion.
0 (default)
1
sec.telnet.apiPort
Specifies whether to use port 23 or 24 for command-line API access.
24 (default)
23
sec.telnet.apiPortIdleTimeout.enable
Specifies whether to allow the command-line API port to time out at the configured time interval or not.
The timeout is set using sec.web.idleSessionTimeout.
0 (default)
1
sec.telnet.diagPortIdleTimeout.enable
Specifies whether to allow the diagnostics port to time out at the configured time interval or not.
The timeout is set using sec.web.idleSessionTimeout.
0 (default)
1
sec.telnet.enable
Specifies whether you can access the system using telnet.
0 (default)
1
sec.web.enable
Specifies whether you can access the system using its web interface.
1 (default)
0
sec.web.httpsOnly
Specifies that the system web interface is accessible only over port 443. Setting this to "1" closes access through port 80 (HTTP).
0 (default)
1
sec.web.idleSessionTimeout
Specifies the number of minutes a session can be idle before it times out.
1
3
5
10 (default)
Polycom, Inc.
65
Security Parameters
60
120
240
480
15
20
30
45
sec.web.port
Specifies the port to use when accessing the system web interface over HTTP. If you change the default, port 80, specify port 1025 or higher and make sure it is not already in use. (This parameter is overridden if security.remoteaccess.web.httpsonly="1".)
Port number (length: at least 1)
80 (default)
sec.usb.disableAll
Set to "1" to prevent use of the system's USB 3.0 ports.
(The USB-C port, which only provides power, can't be turned off.)
0 (default)
1
sec.TLS.cert.sslVerificationDepth
Specifies how many links a certificate chain can have. The term peer certificate refers to any certificate sent by the far-end host when a network connection is being established between the two systems.
0
7
8
5
6
3
4
1
2 (default)
9
10
11
12
sec.TLS.cert.validatePeer.enable
Determines whether your system requires a remote server to present a valid certificate when connecting to it for services, such as provisioning.
Polycom, Inc.
66
Security Parameters
0 (default)
1
sec.TLS.customCaCert.1
Specifies a CA-signed PKI certificate to install on your system.
Your system accepts the following certificate file formats: .pem, .der, and PKCS #7 (which typically has a .p7b filename extension).
String
sec.TLS.customCaCert.2
Specifies a CA-signed PKI certificate to install on your system.
Your system accepts the following certificate file formats: .pem, .der, and PKCS #7 (which typically has a .p7b filename extension).
String
sec.TLS.customCaCert.3
Specifies a CA-signed PKI certificate to install on your system.
Your system accepts the following certificate file formats: .pem, .der, and PKCS #7 (which typically has a .p7b filename extension).
String
sec.TLS.revocation.crl.1
Specifies a CRL to install on your system for certificate revocation checks.
Installing a CRL will fail unless you've installed all of the certificates in the issuing CA's chain of trust for that CRL.
To use this parameter, make sure to set sec.TLS.revocation.ocsp.enable="0".
String
sec.TLS.revocation.crl.2
Specifies a CRL to install on your system for certificate revocation checks.
Installing a CRL will fail unless you've installed all of the certificates in the issuing CA's chain of trust for that CRL.
To use this parameter, make sure to set sec.TLS.revocation.ocsp.enable="0".
String
sec.TLS.revocation.crl.3
Specifies a CRL to install on your system for certificate revocation checks.
Installing a CRL will fail unless you've installed all of the certificates in the issuing CA's chain of trust for that CRL.
To use this parameter, make sure to set sec.TLS.revocation.ocsp.enable="0".
String
sec.TLS.revocation.looseRevocation.enable
CRL method: When you enable this parameter, a certificate in the chain of trust validates without a revocation check if no corresponding CRL from the issuing CA is installed.
Polycom, Inc.
67
Security Parameters
OCSP method: When you enable this parameter, your system considers a revocation check successful if there is no response or the OCSP responder indicates a certificate's status is unknown. Regardless of how you configure this paramter, the following statements apply:
If the OCSP responder indicates a known revoked status, your system treats it as a revocation check failure and doesn't allow the connection. If the OCSP responder indicates a known good status, your system treats it as a successful revocation check and allows the connection
0 (default)
1
sec.TLS.revocation.ocsp.enable
Specifies the certificate revocation method you want to use.
0 (default) - Set to use the CRL method of revocation.
1 - Set to use the OCSP method of revocation.
sec.TLS.revocation.ocsp.responderAddress
Specifies the URI of the OCSP responder (e.g., http://responder.example.com/ocsp). The responder is used when sec.TLS.revocation.ocsp.useResponderInCert is disabled and sometimes even when it's enabled. Polycom recommends you always include a URI in this field regardless of how sec.TLS.revocation.ocsp.useResponderInCert is configured.
To use this parameter, make sure to set sec.TLS.revocation.ocsp.enable="1".
String
sec.TLS.revocation.ocsp.useResponderInCert
Some certificates include the OCSP responder address. When this parameter is enabled, your system attempts to use this address (when present) instead of the global responder address you specified in sec.TLS.revocation.ocsp.responderAddress.
To use this parameter, make sure to set sec.TLS.revocation.ocsp.enable="1".
0 (default)
1
Note:
Only HTTP URLs in a certificate's AIA field are supported.
sec.ssh.enable
Specifies if you can access the command-line API using SSH (port 22).
To access the API, you still must set sec.telnet.enable="1".
1
0 (default)
sec.auth.external.AD.adminGroup
Specifies the Active Directory group whose members should have administrator access to the system. This name must exactly match the name in the AD server for successful authentication.
String (0-512)
sec.auth.external.AD.enable
Specifies whether to authenticate users with Active Directory server. When AD authentication is enabled, users can log in to the system with their network credentials using this format: domain
\user. With this format, users can have accounts on multiple domains.
Polycom, Inc.
68
Security Parameters
0 (default)
1
sec.auth.external.AD.server.address
Specifies the Active Directory server's fully qualified domain name (FQDN) or IP address. If you are using subdomains, append port number 3268 as follows: ad.domain.com:3268.
You can alternatively use RealPresence Resource Manager as an AD server and enter its address here.
If sec.TLS.cert.validatePeer.enable="1", make sure this value matches what is in the AD server certificate. For example, if you enter the AD server IP address here, but the certificate only has the server's FQDN, external authentication will fail.
String (0-256)
sec.auth.external.AD.userGroup
Specifies the Active Directory group whose members should have user access to the system.
This name must exactly match the name in the AD server for successful authentication.
String (0-512)
sec.TLS.minimumVersion
You can restrict your system from using earlier versions of TLS for secure communications.
For example: If you set this parameter to "tlsv1_1", you are disabling TLS 1.0.
7
8
5
6
3
4
1
2 tlsv1_2 (default) tlsv1 tlsv1_1
sec.auth.accountLockout.admin.failedLoginWindow
Determines how many hours the failed login window lasts. The window is a period of time starting with the first failed login attempt and during which subsequent failed attempts are counted against the number allowed.
The counter resets to zero at the end of the window (if the account is not locked because of failed attempts) and after a successful login.
Off (default)
9
10
11
12
Polycom, Inc.
69
Security Parameters
17
18
19
20
13
14
15
16
21
22
23
24
sec.auth.accountLockout.admin.lockoutAttempts
Specifies the number of failed login attempts allowed before the system locks the account.
Off (default)
1
8
9
6
7
4
5
2
3
10
sec.auth.accountLockout.admin.lockoutTime
Specifies the amount of time an account is locked because of failed login attempts. After this period expires, the failed login attempts counter is reset to zero and users can again log in with that account.
1 (default)
2
3
5
sec.auth.admin.id
The local administrator account name.
String (can be a combination of letters and numbers) admin (default)
sec.auth.admin.password
Polycom, Inc.
70
Security Parameters
If set, this password must be entered to access the system through the web interface or command-line API (SSH or telnet).
To successfully provision this parameter, you must set sec.auth.admin.useRoomPassword="0".
String
sec.auth.admin.room.password
If set, this password (also referred to as the Room Password) must be entered to change administrator settings in the local interface.
String
sec.auth.admin.useRoomPassword
When set to "1", the password configured for sec.auth.admin.room.password is also used for accessing the system remotely.
1 (default)
0
sec.auth.admin.room.password.canContainIdOrReverse
Specifies whether the associated ID or its reverse can be part of a password. If this setting is enabled and the ID is "admin", passwords "admin" and "nimda" are allowed.
1 (default)
0
sec.auth.admin.room.password.expirationWarning
Specifies how many days in advance a warning displays indicating that the password will soon expire (if a maximum password age is set).
Off (default)
3
4
1
2
5
6
7
sec.auth.admin.room.password.lowercaseCount
1
2
The minimum number of lowercase letters required for a valid password.
Off (default)
All
sec.auth.admin.room.password.maxAge
The maximum number of days before the password must change.
Off (default)
30
Polycom, Inc.
71
Security Parameters
120
130
140
150
60
90
100
110
160
170
180
sec.auth.admin.room.password.maxRepeatedChars
The maximum number of consecutive repeated characters in a password. For example, if set to
"3", aaa123 is a valid password but aaaa123 is not.
2
3
Off (default)
1
4
sec.auth.admin.room.password.minAge
The minimum number of days before the password can change.
Off (default)
1
5
10
15
20
30
sec.auth.admin.room.password.minChangedChars
The number of characters that must be different or change position in a new password. For example, if set to "3", 123abc can change to 345cde but not to 234bcd.
Off (default)
3
4
1
2
All
sec.auth.admin.room.password.minLength
Polycom, Inc.
72
Security Parameters
11
12
13
14
7
8
9
10
5
6
3
4
1
2
The minimum number of characters required for a valid password.
Off (default)
6
7
4
5
8
15
16
32
sec.auth.admin.room.password.numCount
1
2
The minimum amount of numbers required for a valid password.
Off (default)
All
sec.auth.admin.room.password.rejectPrevPassword
The number of most recent passwords that cannot be reused. If set to "Off", all previous passwords are valid.
2
3
Off (default)
1
Polycom, Inc.
73
Security Parameters
13
14
15
16
9
10
11
12
sec.auth.admin.room.password.specialCharCount
The minimum number of special characters required for a valid password. Supported characters include: @ - _ ! ; $ , \ / & . # *
Off (default)
1
2
All
sec.auth.admin.room.password.uppercaseCount
1
2
The minimum number of uppercase letters required for a valid password.
Off (default)
All
sec.auth.remote.password.canContainIdOrReverse
Specifies whether the associated ID or its reverse can be part of a password. If this setting is enabled and the ID is "admin", passwords "admin" and "nimda" are allowed.
1 (default)
0
sec.auth.remote.password.expirationWarning
Specifies how many days in advance a warning displays indicating that the password will soon expire (if a maximum password age is set).
Off (default)
3
4
1
2
5
6
7
sec.auth.remote.password.lowercaseCount
Polycom, Inc.
74
Security Parameters
110
120
130
140
30
60
90
100
1
2
The minimum number of lowercase letters required for a valid password.
Off (default)
All
sec.auth.remote.password.maxAge
The maximum number of days before the password must change.
Off (default)
150
160
170
180
sec.auth.remote.password.maxRepeatedChars
The maximum number of consecutive repeated characters in a password. For example, if set to
"3", aaa123 is a valid password but aaaa123 is not.
Off (default)
3
4
1
2
sec.auth.remote.password.minAge
Required minimum age of the password (in days) before update is allowed.
Off (default)
1
5
10
15
20
30
Polycom, Inc.
75
Security Parameters
sec.auth.remote.password.minChangedChars
The number of characters that must be different or change position in a new password. For example, if set to "3", 123abc can change to 345cde but not to 234bcd.
Off (default)
3
4
1
2
All
sec.auth.remote.password.minLength
The minimum number of characters required for a valid password.
Off (default)
3
4
1
2
9
10
11
12
7
8
5
6
13
14
15
16
32
sec.auth.remote.password.numCount
The minimum amount of numbers required for a valid password.
Off (default)
1
2
All
sec.auth.remote.password.rejectPrevPassword
The number of most recent passwords that cannot be reused. If set to "Off", all previous passwords are valid.
Polycom, Inc.
76
Security Parameters
12
13
14
15
8
9
10
11
6
7
4
5
2
3
Off (default)
1
16
sec.auth.remote.password.specialCharCount
The minimum number of special characters required for a valid password. Supported characters include: @ - _ ! ; $ , \ / & . # *
Off (default)
1
2
All
sec.auth.remote.password.uppercaseCount
The minimum number of uppercase letters required for a valid password.
Off (default)
1
2
All
sec.auth.snmp.password.canContainIdOrReverse
Specifies whether the associated ID or its reverse can be part of a password. If this setting is enabled and the ID is "admin", passwords "admin" and "nimda" are allowed.
0 (default)
1
sec.auth.snmp.password.lowercaseCount
The minimum number of lowercase letters required for a valid password.
Off (default)
Polycom, Inc.
77
Security Parameters
1
2
All
sec.auth.snmp.password.maxRepeatedChars
The maximum number of consecutive repeated characters in a password. For example, if set to
"3", aaa123 is a valid password but aaaa123 is not.
2
3
Off (default)
1
4
sec.auth.snmp.password.minAge
The minimum number of days before the password can change.
Off (default)
1
5
10
15
20
30
sec.auth.snmp.password.minLength
The minimum number of characters required for a valid password.
8 (default)
9
10
11
12
13
14
15
16
32
sec.auth.snmp.password.numCount
The minimum amount of numbers required for a valid password.
Off (default)
1
2
Polycom, Inc.
78
Security Parameters
8
9
10
11
6
7
4
5
All
sec.auth.snmp.password.rejectPrevPassword
The number of most recent passwords that cannot be reused. If set to "Off", all previous passwords are valid.
2
3
Off (default)
1
12
13
14
15
16
sec.auth.snmp.password.specialCharCount
The minimum number of special characters required for a valid password. Supported characters include: @ - _ ! ; $ , \ / & . # *
Off (default)
1
2
All
sec.auth.snmp.password.uppercaseCount
The minimum number of uppercase letters required for a valid password.
Off (default)
1
2
All
sec.access.room.secCode.enable
Enable or disable the security code required for connecting to the system and sharing content.
1 (default)
0
Polycom, Inc.
79
Security Parameters
sec.serialPort.login.mode
Specifies the credentials necessary for a control system to connect to the RS-232 port: adminpassword (default) - Requires the administrator password, if one has been set, when the control system connects.
usernamepassword - Requires the username and administrator password, if one has been set, when the control system connects.
none - No username or password is required when the control system connects.
Note:
To successfully use this parameter, set device.serial.mode="Control".
Polycom, Inc.
80
Serial Port Parameters
Topics:
▪
This section describes available configuration parameters for your system’s serial port. Included are permitted values and, if applicable, guidance for configuring related parameters.
Serial Port Parameters
Use the following parameters to configure serial port settings on your G7500 system.
device.serial.mode
Specifies the mode used for the RS-232 serial port.
Control (default) - Receives control signals from a touch-panel control. Allows any device connected to the RS-232 port to control the system using API commands.
Off - Disables the serial port.
device.serial.baud
Set this to the same value configured on the serial device.
9600 (default)
19200
38400
57600
115200
device.serial.flowControl
Specifies if you want to use hardware flow control between the connected device and your system.
none (default) hardware
device.serial.parity
Set this to the same value configured on the serial device.
none (default) even odd
device.serial.stopBits
Set this to the same value configured on the serial device.
1 (default)
2
Polycom, Inc.
81
SNMP Parameters
Topics:
▪
This section describes available SNMP configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
SNMP Parameters
Use the following parameters to configure SNMP settings on your G7500 system.
snmp.enable
Allows administrators to monitor the system remotely using SNMP.
You must set this parameter to "1" to configure the other SNMP parameters.
0 (default)
1
snmp.notification.enabled
Enables MIB notifications.
0 (default)
1
snmp.version1.enable
Enables your system to use the SNMPv1 protocol.
Due to security issues, enabling this setting isn't recommended.
0 (default)
1
snmp.version2.enable
Enables your system to use the SNMPv2c protocol.
Due to security issues, enabling this setting isn't recommended.
0 (default)
1
snmp.version3.enable
Enables your system to use the SNMPv3 protocol.
1 (default)
0
snmp.community
Specifies the SNMP community string for your system.
Polycom, Inc.
82
SNMP Parameters
Polycom does not support SNMP write operations for configuring or provisioning systems. The community string is for read operations and outgoing SNMP traps.
String (0-256) public (default)
Note:
For security reasons, do not use the default community string.
snmp.contactName
Specifies the name of the person responsible for remotely managing the system.
String (0-64)
IT Administrator (default)
snmp.locationName
Specifies the system location.
String (0-256)
snmp.systemDesc
Provides details about what kind of system it is.
String (0-256)
Videoconferencing Device (default)
snmp.auth.userId
Specifies the User Security Model (USM) account name for SNMPv3 message transactions.
You must set snmp.version3.enable="1" to configure this parameter.
String (0-64)
snmp.auth.algorithm
Specifies the type of SNMPv3 authentication algorithm used.
You must set snmp.version3.enable="1" to configure this parameter.
SHA (default)
MD5
snmp.auth.password
Specifies the SNMPv3 authentication password.
You must set snmp.version3.enable="1" to configure this parameter.
String (0-48)
snmp.privacyAlgorithm
Specifies the cryptographic privacy algorithm for SNMPv3 packets.
You must set snmp.version3.enable="1" to configure this parameter.
CFB-AES128 (default)
CBC-DES
snmp.privacyPassword
Specifies the SNMPv3 privacy (encryption) password.
Polycom, Inc.
83
SNMP Parameters
You must set snmp.version3.enable="1" to configure this parameter.
String (0-48)
snmp.engineID
Specifies the unique ID of the SNMPv3 engine. This might be needed for matching the configuration of an SNMP console application. The ID is automatically generated, but you can create your own as long as it is between 10 and 32 hexadecimal digits.
Each group of two hex digits can be separated by a colon character (:) to form a full 8-bit value.
A single hex digit delimited on each side with a colon is equivalent to the same hex digit with a leading zero (therefore, :F: is equivalent to :0f:).
You must set snmp.version3.enable="1" to configure this parameter.
String
Must be between 10-32 hexadecimal digits.
Cannot be all zeros or Fs.
snmp.listeningPort
Specifies the port SNMP uses to listen for system messages.
Integer (1-65535)
161 (default)
snmp.transport
Specifies the transport protocol used.
UDP (default)
TCP
snmp.trapTarget.1.enable
Enable to send SNMP traps to an SNMP manager. You can send traps to up to three managers.
1 (default)
0
snmp.trapTarget.1.address
Specifies the IP address of an SNMP manager where SNMP traps are sent.
String (0-255)
snmp.trapTarget.1.messageType
Specifies the type of SNMP message.
Trap (default)
Inform
snmp.trapTarget.1.protocolVersion
Specifies the SNMP version used by the SNMP manager.
v3 (default) v2c v1
snmp.trapTarget.1.port
Polycom, Inc.
84
SNMP Parameters
Specifies the port where SNMP traps are sent.
String (1-65535)
162 (default)
snmp.trapTarget.2.enable
Enable to send SNMP traps to an SNMP manager. You can send traps to up to three managers.
1 (default)
0
snmp.trapTarget.2.address
Specifies the IP address of an SNMP manager where SNMP traps are sent.
String (0-255)
snmp.trapTarget.2.messageType
Specifies the type of SNMP message.
Trap (default)
Inform
snmp.trapTarget.2.protocolVersion
Specifies the SNMP version used by the SNMP manager.
v3 (default) v2c v1
snmp.trapTarget.2.port
Specifies the port where SNMP traps are sent.
String (1-65535)
162 (default)
snmp.trapTarget.3.enable
Enable to send SNMP traps to an SNMP manager. You can send traps to up to three managers.
1 (default)
0
snmp.trapTarget.3.address
Specifies the IP address of an SNMP manager where SNMP traps are sent.
String (0-255)
snmp.trapTarget.3.messageType
Specifies the type of SNMP message.
Trap (default)
Inform
snmp.trapTarget.3.protocolVersion
Specifies the SNMP version used by the SNMP manager.
v3 (default)
Polycom, Inc.
85
v2c v3
snmp.trapTarget.3.port
Specifies the port where SNMP traps are sent.
String (1-65535)
162 (default)
SNMP Parameters
Polycom, Inc.
86
Software Update Parameters
Topics:
▪
This section describes available software update configuration parameters for your system. Included are permitted values and, if applicable, guidance for configuring related parameters.
When you update your system, you also update some of its connected peripheral devices (if those devices have a new version available). Depending on your setup, these devices might include:
▪ Polycom IP Table Microphone
▪ Polycom IP Ceiling Microphone
▪ Polycom Microphone IP Adapter
Software Update Parameters
Use the following parameters to configure software update settings on your G7500 system.
upgrade.auto.enable
Controls whether the software of your system and its connected peripheral devices automatically updates.
0 (default)
1
upgrade.auto.timeFrame.enable
If you've configured automatic software updates (upgrade.auto.enable="1"), you can restrict those updates to occur only during a maintenance window.
If set to "1", make sure you also configure upgrade.auto.timeFrame.startTime and upgrade.auto.timeFrame.stopTime.
0 (default)
1
upgrade.auto.timeFrame.startTime
Specifies when the maintenance window starts. Set a value using 24-hour clock format
(HH:MM). For example, "23:30" is an acceptable value.
String
18:00 (default)
upgrade.auto.timeFrame.stopTime
Specifies when the maintenance window ends. Set a value using 24-hour clock format
(HH:MM). For example, "05:30" is an acceptable value.
String
07:00 (default)
upgrade.auto.polling.interval
Polycom, Inc.
87
Software Update Parameters
If you've configured automatic software updates (upgrade.auto.enable="1"), you can specify how often (in seconds) your system checks with RealPresence Resource Manager to see if there's a new update to download. The default value "3600" means your system checks for updates once every hour.
Doing either of the following turns this feature off:
Disable provisioning (you can do this only in the system web interface).
Enable an automatic update maintenance window by setting upgrade.auto.timeFrame.enable="1". (The maintenance window takes priority over automatic polling.)
Integer > 300
3600 (default)
Polycom, Inc.
88
Video Parameters
Topics:
▪
Provisioning Camera Parameters
▪
This section describes available video configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Provisioning Camera Parameters
Using the video.camera.[index].type parameter, you can configure parameters differently for the following cameras supported by your G7500 system:
▪ Polycom EagleEye IV 4x
▪ Polycom EagleEye IV 12x
▪ Polycom EagleEye Director II
▪ Polycom EagleEye Producer
The following examples show you how to configure cameras based on type.
Per-Camera Configuration Examples
Camera Type Configuration Per-Camera Configuration
video.camera.1.type= EagleEyeIV12x video.camera.2.type= EagleEyeDirectorII video.camera.1.brightness= “14” video.camera.1.backlightCompensation= “True” video.camera.2.trackingMode= “FrameSpeaker” video.camera.2.trackingSpeed= “Normal”
You also can configure common parameters that apply to all camera types.
Configure Common and Per-Camera Parameters
You can configure parameters that apply to all cameras along with parameters that apply only to a specific type of camera. The following example shows how you might configure a mix of common and per-camera parameters.
Procedure
1.
Set some common configurations for any type of camera.
video.camera.backlightCompensation="False" video.camera.brightness="13" video.camera.sleepMode="Save Energy" video.camera.groupViewSize="Medium"
Polycom, Inc.
89
Video Parameters
2.
Assign an index to a specific camera model for per-camera configurations.
video.camera.1.type="EagleEyeDirectorII"
3.
Set a per-camera configuration.
video.camera.1.trackingMode="FrameSpeaker"
Video Parameters
Use the following parameters to configure video settings on your G7500 system.
Note:
Remember that per-camera configurations override common camera configurations. For example, if you set video.camera.[index].videoQuality for a specific camera, the video.camera.videoQuality parameter is overridden.
video.layout.contentMirror
Specifies your content layout preference during an active call when using dual monitors.
0 (default) - Content displays only on the secondary monitor.
1 - Content displays on the primary and secondary monitors.
video.layout.selfviewPIP
Specifies your Self View layout preference during an active call when using dual monitors.
0 (default) - Self View displays on the entire screen of the secondary monitor.
1 - Self View displays in the corner of the secondary monitor.
video.monitor.1.display
Specifies how you want to configure the primary monitor.
auto (default) - The highest-supported resolution of the primary monitor is detected.
manual - Lets you set the monitor resolution with video.monitor.1.resolution.
video.monitor.1.resolution
Specifies the primary monitor resolution.
Monitor resolution is automatically configured if you set video.monitor.1.display="auto".
3840x2160p 25Hz
3840x2160p 30Hz
3840x2160p 50Hz
3840x2160p 60Hz
1920x1080p 50Hz
1920x1080p 60Hz (default)
video.monitor.2.display
Specifies how you want to configure the secondary monitor.
off - Disables the secondary monitor.
auto (default) - The highest-supported resolution of the secondary monitor is detected.
Polycom, Inc.
90
Video Parameters
video.camera.[index].type
Choose a camera type that corresponds to [index], where [index] can be 1-4.
The value set for [index] in this parameter and related parameters determines the configuration settings for the camera type you specify.
For example, setting video.camera.1.type="EagleEyeDirectorII" gives you a reference index of 1 to configure your Polycom EagleEye Director II camera settings.
EagleEyeIV4x
EagleEyeIV12x
EagleEyeProducer
EagleEyeDirectorII
video.camera.[index].backlightCompensation
Specifies if the camera automatically adjusts for a bright background. Backlight compensation is best used in situations where the subject appears darker than the background.
Use this to configure the camera type identified with the video.camera.[index].type parameter.
True
False (default)
video.camera.[index].brightness
Specifies how bright the video is.
Use this to configure the camera type identified with the video.camera.[index].type parameter.
Integer (0-21)
11 (default)
video.camera.[index].groupViewSize
Specifies the framing size used by the EagleEye Director II or EagleEye Producer camera.
Use this to configure the camera type identified with the video.camera.[index].type parameter.
Medium (default) - Average-sized frame.
Wide - Most expansive frame.
Tight - Close-up frame.
video.camera.[index].name
Specifies a name for the camera.
Use this to configure the camera type identified with the video.camera.[index].type parameter.
String (0-32)
video.camera.[index].orientation
Specifies whether the video display is oriented normally or inverted (upside down).
Use this to configure the camera type identified with the video.camera.[index].type parameter.
Normal (default)
Inverted
video.camera.[index].roomViewPIP
When enabled, a Picture-in-Picture window displays showing a wide angle of the room in addition to the main window showing the primary speaker(s).
Polycom, Inc.
91
Video Parameters
This parameter is supported when using a camera with tracking features, such as the EagleEye
Director II.
True (default)
False
video.camera.[index].saturation
Specifies the intensity of the video color.
Use this to configure the camera type identified with the video.camera.[index].type parameter.
Integer (0-14)
6 (default)
video.camera.[index].trackingMode
Specifies the tracking mode used by the EagleEye Director II or EagleEye Producer camera:
Use this to configure the camera type identified with the video.camera.[index].type parameter.
FrameSpeaker (default) - Enables the automatic locating and framing of the active speaker.
When someone else starts speaking, the camera switches that person. Note that when the local microphone is muted, the camera tracking mode automatically switches to "FrameGroup."
FrameGroup - Enables the automatic locating and framing of participants in the room without displaying camera motion.
FrameGroupWithTransition - (EagleEye Producer camera only) Enables the automatic locating and framing of participants in the room while displaying camera motion. For example, if someone enters the room, you might see the camera pan until that person is in view.
Off - Disables automatic tracking. All camera control must be handled manually.
video.camera.[index].trackingSpeed
Determines how quickly an EagleEye Director II or EagleEye Producer camera finds and switches to the new speaker. The room environment can influence how fast new speakers are located.
Use this to configure the camera type identified with the video.camera.[index].type parameter.
Normal (default)
Slow
Fast
video.camera.[index].videoQuality
Sharpness - Gives preference to resolution over frames per second. With this setting, moderateto-heavy motion at low call rates can cause some frames to drop.
Motion - Gives preference to frames per second over resolution.
Use this to configure the camera type identified with the video.camera.[index].type parameter.
Sharpness (default)
Motion
video.camera.[index].whiteBalanceMode
Specifies how the camera compensates for light source variations in the room. Use this to configure the camera type identified with the video.camera.[index].type parameter.
Fixed color temperature values are measured in Kelvin and correspond to the color of ambient light in a room.
Polycom, Inc.
92
Video Parameters
4160k
4640k
5120k
5600k
2300k
2856k
3450k
4230k
The following color temperatures are available with the EagleEye Director II camera: 3200k,
3680k, 4160k, 5120k, and 5600k.
The following color temperatures are available with the EagleEye IV and EagleEye Producer cameras: 2300k, 2856k, 3450k, 4230k, 5200k, and 6504k.
Auto (default) - Setting this value is recommended for most situations. It calculates the best white balance setting based on lighting conditions in the room.
3200k
3680k
5200k
6504k
Manual - Setting this value may be necessary for rooms where the "Auto" and fixed values don’t provide acceptable color reproduction. Remember, however, you’ll have to manually white balance the camera.
video.camera.autoUpdate.enable
Enable or disable automatic software updates to your HDCI-connected Polycom camera.
If newer software than what the camera has is detected, the camera updates automatically when the system isn't in a call. (However, if during a call you connect a camera that isn't running the latest software, the call ends and the update starts.)
1
0 (default)
video.camera.backlightCompensation
Specifies whether to have the camera automatically adjust for a bright background. Backlight compensation is best used in situations where the subject appears darker than the background.
True
False (default)
video.camera.brightness
Specifies how bright the video is.
Integer (0-21)
11 (default)
video.camera.farControlNearCamera
Specifies whether the far site can pan, tilt, or zoom the near-site camera. When you enable this setting, a user at the far site can control the framing and angle of the camera for the best view of the near site. This is also called Far End Camera Control (FECC).
Polycom, Inc.
93
Video Parameters
1 (default)
0
video.camera.groupViewSize
Specifies the framing size used by the EagleEye Director II or EagleEye Producer camera.
Medium (default) - Average-sized frame.
Wide - Most expansive frame.
Tight - Close-up frame.
video.camera.name
Specifies a name for the camera.
String (0-32)
video.camera.orientation
Specifies whether the video display is oriented normally or inverted (upside down).
Normal (default)
Inverted
video.camera.powerFrequency
Specifies the power-line frequency for your system. In most cases, this should be the same as your display frequency.
Your system typically defaults to the correct power-line frequency based on the video standard used in the country where it's located. This parameter helps you adapt the system to areas where the frequency doesn't match the video standard. You might also need to change this configuration to avoid flicker from fluorescent lights in the room.
50
60 (default)
video.camera.preset.snapshot.enable
Enables or disables the use of snapshot icons that represent camera presets.
To see a preset icon, you must enable this setting before configuring the preset.
1 (default)
0
video.camera.roomViewPIP
When enabled, a picture-in-picture window displays showing a wide angle of the room in addition to the main window showing the primary speaker(s).
This parameter is supported when using a camera with tracking features, such as the EagleEye
Director II.
True (default)
False
video.camera.saturation
Specifies the intensity of the video color.
Integer (0-14)
6 (default)
video.camera.sleepMode
Polycom, Inc.
94
Video Parameters
Specifies a sleep mode for your camera.
Save Energy (default) - Puts the camera into standby mode to save power (the camera spins to the rear and faces down). Remember the following when setting this value in conjunction with device.screenSaver.mode:
When device.screenSaver.mode="Black", it takes a few seconds for the camera to send an image.
When device.screenSaver.mode="NoSignal", the camera is sending an image by the time the display synchronizes with the system.
Fast Wake Up - The camera provides an image as soon as the monitor wakes. While asleep, the camera faces forward. Remember the following when setting this value in conjunction with device.screenSaver.mode:
When device.screenSaver.mode="Black", an image displays more quickly, but be aware that this uses maximum power.
When device.screenSaver.mode="NoSignal", the display synchronizes with the system. This can take a few seconds but may conserve energy depending on the monitor.
video.camera.trackingMode
Specifies the tracking mode used by the EagleEye Director II or EagleEye Producer camera:
FrameSpeaker (default) - Enables the automatic locating and framing of the active speaker.
When someone else starts speaking, the camera switches that person. Note that when the local microphone is muted, the camera tracking mode automatically switches to "FrameGroup".
FrameGroup - Enables the automatic locating and framing of participants in the room without displaying camera motion.
FrameGroupWithTransition - (EagleEye Producer camera only) Enables the automatic locating and framing of participants in the room while displaying camera motion. For example, if someone enters the room, you might see the camera pan until that person is in view.
Off - Disables automatic tracking. All camera control must be handled manually.
video.camera.trackingSpeed
Determines how quickly an EagleEye Director II or EagleEye Producer camera finds and switches to the new speaker. The room environment can influence how fast new speakers are located.
Normal (default)
Slow
Fast
video.camera.videoQuality
Specifies your camera video quality preference.
Sharpness (default) - Gives preference to resolution over frames per second. With this setting, moderate-to-heavy motion at low call rates can cause some frames to drop.
Motion - Gives preference to frames per second over resolution.
video.camera.whiteBalanceMode
Specifies how the camera compensates for light source variations in the room.
Fixed color temperature values are measured in Kelvin and correspond to the color of ambient light in a room.
Polycom, Inc.
95
Video Parameters
4160k
4640k
5120k
5600k
2300k
2856k
3450k
4230k
The following color temperatures are available with the EagleEye Director II camera: 3200k,
3680k, 4160k, 5120k, and 5600k.
The following color temperatures are available with the EagleEye IV and EagleEye Producer cameras: 2300k, 2856k, 3450k, 4230k, 5200k, and 6504k.
Auto (default) - Setting this value is recommended for most situations. It calculates the best white balance setting based on lighting conditions in the room.
3200k
3680k
5200k
6504k
Manual - Setting this value may be necessary for rooms where the "Auto" and fixed values don’t provide acceptable color reproduction.
video.content.name
Specifies a name for the device connected to your system using HDMI. This device is typically used to share content.
String (0-32)
Polycom, Inc.
96
VoIP Parameters
Topics:
▪
Using Provisioning Service Credentials to Register with SIP
▪
This section describes available VoIP configuration parameters. Included are permitted values and, if applicable, guidance for configuring related parameters.
Using Provisioning Service Credentials to Register with SIP
You can register your G7500 system with a SIP service using the same credentials you used to register with your provisioning service.
To do this, set voIpProt.SIP.auth.useLoginCredentials=“1”
.
With this parameter, provisioning separate username, password, and domain parameters for the SIP service isn’t necessary. For example, if you set voIpProt.SIP.auth.useLoginCredentials=“1”
, you don’t have to set voIpProt.SIP.auth.userId, voIpProt.SIP.auth.password, and voIpProt.SIP.auth.domain.
VoIP Parameters
Use the following parameters to configure VoIP settings on your G7500 system.
voIpProt.SIP.auth.domain
Specifies the domain that your SIP username belongs to.
String
voIpProt.SIP.sbcKeepAlive.enable
Specifies whether to regularly transmit keep-alive messages on the SIP signaling channel and on RTP sessions part of SIP calls. Keep-alive messages maintain connections through firewall/NAT devices that are often used at network edges.
If your system is in an Avaya SIP environment, Polycom recommends that you disable this setting to allow calls to fully connect.
1 (default)
0
voIpProt.H323.e164
You can place point-to-point calls using this extension if both systems are registered with a gatekeeper. The extension is also used by gatekeepers and gateways use to identify your system.
Your organization's dial plan might define the extensions you can use.
String (0-128)
Polycom, Inc.
97
VoIP Parameters
${h323_e164} - RealPresence Resource Manager accepts this value to automatically configure the parameter.
voIpProt.H323.enable
Enables or disables the ability for your system to use the H.323 protocol.
You must set to "1" to use other voIpProt.H323.* parameters.
If set to "0", you can't also set voIpProt.SIP.enable="0".
0 (default)
1
voIpProt.H323.gk.auth.enable
Enables support for H.235 Annex D Authentication.
When H.235 Annex D Authentication is enabled, the H.323 gatekeeper ensures that only trusted
H.323 endpoints can access the gatekeeper.
To use this parameter, you should set voIpProt.H323.gk.mode="Specify".
0 (default)
1
voIpProt.H323.gk.auth.password
Specifies a password if authentication is required for registering with the gatekeeper.
To use this parameter, you should set voIpProt.H323.gk.mode="Specify" and voIpProt.H323.gk.auth.enable="1".
String
voIpProt.H323.gk.auth.userId
Specifies a username if authentication is required for registering with the gatekeeper.
To use this parameter, you should set voIpProt.H323.gk.mode="Specify" and voIpProt.H323.gk.auth.enable="1".
String (0-62)
voIpProt.H323.gk.ipAddress
The gatekeeper IPv4 address the system registers with.
As part of the registration process, the gatekeeper might return alternate gatekeepers. If communication with the primary gatekeeper is lost, your system registers with the alternate gatekeeper but continues to poll the primary gatekeeper. If the system re-establishes communication with the primary gatekeeper, it unregisters from the alternate gatekeeper.
What you can set here is determined by how you’ve configured voIpProt.H323.gk.mode:
Off - Setting the gatekeeper IP address isn’t needed.
Auto - Setting the gatekeeper IP address isn’t needed.
Specify - Enter the gatekeeper IP address or name (e.g., 10.11.12.13 or gatekeeper.companyname.usa.com).
String (0-255)
voIpProt.H323.gk.mode
Specifies if you want to use a gatekeeper for H.323 services.
Off (default) - Calls do not use a gatekeeper.
Polycom, Inc.
98
VoIP Parameters
Auto - System tries to automatically find an available gatekeeper.
Specify - Calls use the specified gatekeeper. Set this value if if you want to use voIpProt.H323.gk.auth.enable.
voIpProt.H323.name
How gatekeepers and gateways identify your system. You can make point-to-point calls using H.
323 names if both systems are registered to a gatekeeper.
The value here is the same set for device.local.deviceName unless you change it. (Your organization's dial plan might define the name you can use.)
String (0-36)
${h323_ID} - RealPresence Resource Manager accepts this value to automatically configure the parameter.
voIpProt.SIP.auth.useLoginCredentials
Specifies if you want to register with a SIP service using the same credentials you used for registering with a provisioning service.
With this parameter, provisioning separate username, password, and domain parameters for the
SIP service isn’t necessary.
0 (default)
1
voIpProt.SIP.auth.password
The password associated with the username for authenticating your system with a SIP registrar server.
String
voIpProt.SIP.bfcpTransportPreference
Controls content sharing negotiation behavior. Using the Binary Floor Control Protocol (BFCP), a relationship is established between the floor control server and its clients. What you set here determines how network traffic flows between the server and clients.
Prefer_UDP (default) - Starts resource sharing using UDP but falls back to TCP if needed.
Prefer_TCP - Starts resource sharing using TCP but falls back to UDP if needed.
UDP_ONLY - Shares resources only using UDP. If UDP is unavailable, content sharing in a separate video stream isn't available.
TCP_ONLY - Shares resources only through TCP. If TCP is unavailable, content sharing in a separate video stream isn't available.
Note:
TCP is typically known as slightly slower but more reliable than UDP. It is not supported under some circumstances, such as with session border controllers
(SBCs).
voIpProt.SIP.enable
Enables or disables the ability for your system to use the SIP protocol.
You must set to "1" to use other voIpProt.SIP.* parameters.
If set to "0", you can't also set voIpProt.H323.enable="0".
0 (default)
1
Polycom, Inc.
99
VoIP Parameters
voIpProt.SIP.forceConnectionReuse
When disabled (recommended), the system uses an ephemeral source port for outgoing SIP messages.
When enabled, the system uses the active SIP listening port as the source port (5060 or 5061, depending on the negotiated SIP transport protocol in use). This can be useful to establish correct operation with remote SIP peer devices, which require that the source port match the contact port in SIP messages.
0 (default)
1
voIpProt.SIP.proxyServer
The IP address or fully qualified domain name (FQDN) of the SIP proxy server. If you don't set this, the registrar server address is used. If you also leave voIpProt.SIP.registrarServer blank, there is no SIP proxy server.
SIP signaling by default is sent to ports 5060 (TCP) and 5061 (TLS) on the proxy server.
The syntax for this is the same as voIpProt.SIP.registrarServer.
String (0-255)
voIpProt.SIP.registrarServer
The IP address or fully qualified domain name (FQDN) of the SIP registrar server. If registering a remote system with an edge server, use that server's FQDN.
SIP signaling by default is sent to ports 5060 (TCP) and 5061 (TLS) on the registrar server.
Enter the address and port using the following format: IP_Address:Port.
The IP_Address can be an IPv4 address or an FQDN (e.g., servername.company.com:6050).
String (0-255)
voIpProt.SIP.registrarServerType
Specifies the type of SIP registrar server you're using.
unknown
voIpProt.SIP.serverType
Specifies whether to automatically or manually set the SIP server's IP address.
If set to "Auto", you don't have to set voIpProt.SIP.transport, voIpProt.SIP.registrarServer, or voIpProt.SIP.proxyServer.
Specify (default)
Auto
voIpProt.SIP.transport
Sets the protocol your system uses for SIP signaling (your SIP network determines which protocol is required).
Auto (default) - Enables automatic negotiation of protocols in the following order: TLS, TCP, and
UDP. This is the recommended setting for most environments.
TLS - Provides secure SIP signaling. TLS is available only when your system is registered with a SIP server that supports it. If you set this, your system ignores TCP/UDP port 5060.
TCP - Provides reliable transport via TCP.
UDP - Provides best-effort transport via UDP.
Polycom, Inc.
100
VoIP Parameters
voIpProt.SIP.auth.userId
Specifices the username for connecting your system with a SIP registrar server (e.g., marySmith). If the SIP proxy requires authentication, this parameter and voIpProt.SIP.auth.password cannot be blank.
String
voIpProt.SIP.userName
Specifies the SIP address or name of the system (e.g., [email protected]).
If you leave this blank, the system IP address is used for authentication.
String
${sip_alias} - RealPresence Resource Manager accepts this value to automatically configure the parameter.
Polycom, Inc.
101
Download
Advertisement
Key features
High-quality video and audio for crystal-clear communication
Easy-to-use interface for a seamless user experience
Flexible configuration options to meet the needs of any business
Advanced features such as content sharing, recording, and transcription
Seamless integration with Microsoft Exchange Server for easy scheduling and management
Frequently asked questions
The Polycom G7500 can be connected to your network using an Ethernet cable or a Wi-Fi connection.
To start a video conference, simply dial the desired number or select the contact from your directory.
To share content during a video conference, simply click the "Share" button and select the desired content.