Ruud Achiever Plus
™
Series
Two-Stage Air Conditioners
Air Conditioners
UA17 Series
UA17 Series
Efficiencies up to 17 SEER/13 EER
Nominal Sizes 2, 3, 4 & 5 Ton
[7.03, 10.6, 14.06 & 17.6 kW]
Cooling Capacities 17.3 to 60.5 kBTU
[5.7 to 17.7 kW]
Seasonal Energy Efficiency Ratio -
SEER
THIS MODEL
17.00
10.0
17.0
USES LESS ENERGY
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star.
Ask your Contractor for details or visit www.energystar.gov.”
• EcoNet ™ Enabled product. The EcoNet Smart Home System provides advanced air & water control for maximum energy savings and ideal comfort.
• New composite base pan – dampens sound, captures louver panels, eliminates corrosion and reduces number of fasteners needed
• Powder coat paint system – for a long lasting professional finish
• The Two Stage Copeland Scroll ™ UltraTech ™ Compressor modulates between two capacity settings – 67% and
100% – providing more precise temperature control, lower humidity and greater efficiency in comparison to single stage compressors. It uses 70% fewer moving parts which also increases efficiency and reliability.
• Modern cabinet aesthetics – increased curb appeal with visually appealing design
• Curved louver panels – provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity
• Optimized fan orifice – optimizes airflow and reduces unit sound
• Rust resistant screws – confirmed through 1500-hour salt spray testing
• PlusOne™
Expanded Valve Space
– 3"-4"-5" service valve space – provides a minimum working area of 27-square inches for easier access
• PlusOne™
Triple Service Access
– 15" wide, industry leading corner service access – makes repairs easier and faster.
The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly
• Diagnostic service window with two-fastener opening –
provides access to the high and low pressure.
• External gauge port access – allows easy connection of
“low-loss” gauge ports
• Single-row condenser coil – makes unit lighter and allows
thorough coil cleaning to maintain “out of the box” performance
• 35% fewer cabinet fasteners and fastener-free base – allow for faster access to internal components and hassle-free panel removal
• Service trays – hold fasteners or caps during service calls
• QR code – provides technical information on demand for faster service calls
• Fan motor harness with extra long wires allows unit top to be removed without disconnecting fan wire.
• High and low pressure standard on all models.
Rely on Ruud.™
FORM NO. A22-223 REV. 3
Table of Contents
UA17 Series
Standard Feature ......................................................................................................3
Available SKUs ........................................................................................................3
Features & Benefits ..............................................................................................4-6
Model Number Identification ................................................................................7-8
General Data/Electrical Data ....................................................................................9
Accessories ..........................................................................................................10
Weighted Sound Power ..........................................................................................10
Smart Home Systems ......................................................................................11-12
Unit Dimensions......................................................................................................13
Clearances ..............................................................................................................14
Wiring Diagrams ................................................................................................15-16
Application Guidelines ......................................................................................15-16
Refrigerant Line Size Information ......................................................................17-18
Performance Data ............................................................................................19-20
Guide Specifications ..............................................................................................21
Limited Warranty ....................................................................................................22
2
Rely on Ruud.™
Standard Feature/Available SKUs
UA17 Series
Standard Feature Table
Feature
R-410A Refrigerant
Maximum SEER
Maximum EER
EcoNet Enabled
Two Stage Copeland Scroll ™ UltraTech ™ Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15" Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Single row condenser coil
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays
√ = Standard
Available SKUs
Available Models
UA1724AJ2CB
UA1736AJ2CB
UA1748AJ2CB
UA1760AJ2CB
24
STANDARD FEATURES
√
17
13
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
36
√
17
13
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
48
√
17
13
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Description
Achiever Plus
™ Series 2 ton 17 SEER Two Stage Air Conditioner-208/230/1/60
Achiever Plus ™ Series 3 ton 17 SEER Two Stage Air Conditioner-208/230/1/60
Achiever Plus ™ Series 4 ton 17 SEER Two Stage Air Conditioner-208/230/1/60
Achiever Plus
™ Series 5 ton 17 SEER Two Stage Air Conditioner-208/230/1/60
60
√
16
12.5
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Rely on Ruud.™
3
Features & Benefits
UA17 Series
Introduction to UA17 Air Conditioner
The UA17 is our EcoNet Enabled 17 SEER Two-Stage Air Conditioner and is part of the Ruud Air Conditioner product line that extends from 13 to 20 SEER. This highly featured and reliable air conditioner is designed for years of reliable, efficient operation when matched with Ruud indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators.
The UA17 is exclusively designed to operate with the EcoNet
Smart Home System. Developed by Ruud, The EcoNet Smart
Home System allows homeowners to manage select highefficiency, EcoNet Enabled air conditioners, heat pumps, gas furnaces, air handlers and water heaters from anywhere.
EcoNet Enabled products in a home are connected through standard HVAC wiring; then, contractors have the option of adding an EcoNet WiFi kit (
1
) so the homeowner can access everything remotely through a free mobile app or mobile-friendly website. The Control Center (
2
) acts as both a thermostat for the heating and cooling system, and a remote control for connected water heaters.
1 2
Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover, revealing the industry’s largest 15" wide and 14" tall control area (
10
). With all this room in the control area the high voltage electrical whip (
11
) can easily be inserted through the right size opening in the
bottom of the control area. Routing it leads directly to contractor lugs for connection. The low voltage control wires (
12
) are easily connected to the units low voltage wiring. If contactor or capacitor (
13
) needs to be replaced there is more than adequate space to make the repair. The service window (
14
) can be removed by removing two screws, to access the high and low pressure switches and view interior of unit. (
15
) (High and low pressure is standard on UA17 models).
14
The EcoNet Smart Home System is the first integrated system for a home’s Heating, Cooling and Water Heating equipment – allowing homeowners to manage the products that consume up to 65% of their home’s energy. EcoNet sets Ruud, our distributor and contactor customers apart in the industry with a unique, advanced and efficient technology solution.
3
10
12
13
11
15
If in the rare event, greater access is needed to internal components, such as the compressor, the entire corner of the unit can be removed along with the top cover assembly to have unprecedented access to interior of the unit (
16
). Extra wire length is incorporated into each outdoor fan and compressor so top cover and control panel can be positioned next to the unit. With minimal effort the plug can be removed from the compressor and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit (
17
).
Outdoor coil heights range from as short as 35" to 51". Disassembly to this degree and complete reassembly only takes a first time service technician less than 10 minutes. (
17
)
20
18
4
6
6
8
5 7
Our unique composite base (
3
) reduces sound emission, eliminates rattles, significantly reduces fasteners, eliminates corrosion and has integrated brass compressor attachment inserts (
4
).
Furthermore it has incorporated into the design, water manage ment features, means for hand placement (
5
) for unit maneuvering, screw trays (
6
) and inserts for lifting off unit pad. (
7
)
Service Valves (
8
) are rigidly mounted in the composite base with 3" between suction and discharge valves, 4" clearance below service valves and a minimum of 5" above the service valves, creating industry leading ease of installation. The minimum
9
16
All units utilize strong formed louver panels which provide industry leading coil protection. Louver removal for coil cleaning is accomplished by removing one screw and lifting the panel out of the composite base pan. (
19
) All UA17 units utilize single row coils (
18
) making cleaning easy and complete, restoring the performance of the air conditioner back to out of the box performance levels year after year.
17
19
27 square-inches around the service valves allows ample room to remove service valve schrader prior to brazing, plenty of clearance for easy brazing of the suction and discharge lines to service valve outlets, easy access and hookup of low loss refrigerant gauges (
9
), and access to the service valve caps for opening. For applications with long-line lengths up to 250 feet total equivalent length, up to 200 feet condenser above evaporator, or up to 80 feet evaporator above condenser, the long-line instructions in the installation manual should be followed.
4
Rely on Ruud.™
The outdoor fan motor has sleeve bearings and is inherently protected. The motor is totally enclosed for maximum protection from weather, dust and corrosion. (
20
) Access to the outdoor fan is made by removing four fasteners from the fan grille. The outdoor fan can be removed from the fan grille by removing 4 fasteners in the rare case outdoor fan motor fails.
Each cabinet has optimized composite (
21
) fan orifice assuring efficient and quiet airflow.
21
The entire cabinet has post powder paint (
22
) achieving 1000 hour salt spray rating, allowing the cabinet to retain its aesthetics throughout its life.
26
22
25
24
23
Two Stage Copeland Scroll
™
UltraTech
™ compressors with
standard internal pressure relief and internal thermal overload are used on all capacities assuring longevity of high efficient and quiet operation for the life of the product.
All models come standard with high and low pressure controls.
Each unit is shipped with filter drier for field installation and will trap any moisture or dirt that could contaminate the refrigerant system.
27
All cabinets have industry leading structural strength due to the composite base pan (
23
), interlocking corner post (
24
), formed curved louver panels (
25
) and drawn top cover (
26
) making it the most durable cabinet on the market today.
Each UA17 capacity has undergone rigorous psychometric testing to assure performance ratings of capacity, SEER and EER per AHRI Standard 210/240 rating conditions. Also each unit bears the UL mark and each unit is certified to UL 1995 safety standards.
Each unit has undergone specific strain and modal testing to assure tubing (
27
) is outside the units natural frequency and that the suction and discharge lines connected to the compressor withstand any starting, steady state operation, or shut down forces imposed by the compressor.
Features & Benefits
UA17 Series
All units have been sound tested in sound chamber to AHRI 270 rating conditions, and A-weighted Sound Power Level tables produced, assuring units have acceptable noise qualities (see page 10). Each unit has been ran in cooling operation at 95°F and 82°F and sound ratings for the UA17 range from as low as
72.3 dBA to 76.7 dBA.
All units have been ship tested to assure units meet stringent
“over the road” shipping conditions.
As manufactured, all units in the UA17 family have cooling capability to 55 °F. Addition of low ambient control will allow the unit to operate down to 0°F. Factory testing is performed on each unit. All component parts meet well defined specification and continually go through receiving inspections. Each component installed on a unit is scanned, assuring correct component utilization for a given unit capacity and voltage. All condenser coils are leak tested with pressurization test to 550#’s and once installed and assembled, each units’ complete refrigerant
system is helium leak tested. All units are fully charged from the factory for up to 15 feet of piping. All units are factory run tested.
The UA17 has a 10-year conditional unit replacement warranty
(registration required) and a 10 year limited parts warranty.
Optional Accessories
(Refer to accessory chart for model #)
Compressor Crankcase Heater
Protects against refrigerant migration that can occur during low ambient operation
Compressor Sound Cover
• Reinforced vinyl compressor cover containing a 1½ inch thick batt of fiberglass insulation
• Open edges are sealed with a one-inch wide hook and loop fastening tape
Compressor Hard Start Kit
• Single-phase units are equipped with a PSC compressor motor, this type of motor normally does not need a potential relay and start capacitor
• Kit may be required to increase the compressor starting torque, in conditions such as low voltage
Low Ambient Kit
• Air conditioners operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional controls
• This Kit can be added in the field enabling unit to operate properly down to 0° in the cooling mode
• Crankcase heater and freezestat should be installed on compressors equipped with a low ambient kit
3"/6"/12"
• Gray high density polyethylene feet are available to raise unit off of mounting surface away from moisture
Decorative Top
• Can be installed on fan grille
Rely on Ruud.™
5
Features & Benefits
UA17 Series
Accessories
EcoNet Control Center
The EcoNet Control Center serves as the hub of communication for a home’s Heating, Cooling and
Water Heating systems, and is required to operate an EcoNet
Enabled Heating & Cooling system in a fully communicating mode.
UETST601SYS
WiFi Kit for Heating and Cooling Systems
The WiFi kit is required to remotely operate EcoNet Enabled
Heating and Cooling Systems from the EcoNet Web portal and mobile apps.
UEWRA630SYS
6
Rely on Ruud.™
Model Number Identification
UA17 Series
Rely on Ruud.™
7
Model Number Identification
UA17 Series
8
Rely on Ruud.™
General Data/Electrical Data
UA17 Series
Physical Data
Model No.
Nominal Tonnage
Valve Connections
UA1724A
2.0
UA1736A
3.0
UA1748A
4.0
UA1760A
5.0
Liquid Line O.D. – in.
Suction Line O.D. – in.
3/8
3/4
128
3/8
3/4
151
3/8
7/8
204
3/8
7/8
223
Refrigerant (R-410A) furnished oz.¹
Compressor Type
Outdoor Coil
Scroll
Net face area – Outer Coil
Net face area – Inner Coil
Tube diameter – in.
Number of rows
Fins per inch
19.8
—
0.375
1
20
22.2
—
0.375
1
22
32.3
—
0.375
1
22
32.3
—
0.375
1
22
Outdoor Fan
Shipping weight – lbs.
Operating weight – lbs.
Diameter – in.
Number of blades
Motor hp
CFM
RPM watts
24
3
1/5
3326
850
112
200
193
24
3
1/5
3540
820
112
209
202
26
3
1/2
4251
646
132
297
290
26
3
1/2
5133
825
113
298
291
Electrical Data
Line Voltage Data (Volts-Phase-Hz)
Maximum overcurrent protection (amps)²
Minimum circuit ampacity³
Compressor
208/230-1-60
25
16
208/230-1-60
35
21
208/230-1-60
50
32
208/230-1-60
70
42
Rated load amps
Locked rotor amps
11.7
58.3
15.3
83
21.2
104
28.8
152.9
Condenser Fan Motor
Full load amps
Locked rotor amps
1.4
—
1.2
—
5.3
—
5.3
—
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
Rely on Ruud.™
9
Accessories/Weighted Sound Power
UA17 Series
Accessories
Model No.
EcoNet Control Center
WiFi Kit for Heating & Cooling
Compressor crankcase heater*
Low ambient control
Freeze Stat
Compressor sound cover
Compressor hard start kit
Heat pump Riser 6 in.
Liquid Line Solenoid
(24 VAC, 50/60 Hz)
Liquid Line Solenoid
(120/240 VAC, 50/60 Hz)
Solenoid Valve
Solenoid Coil
Solenoid Valve
Solenoid Coil
*Crankcase Heater recommended with Low Ambient Kit.
UA1724
RETST601SYS
REWRA630SYS
44-17402-49
RXAD-A08
50313
68-23427-26
SK-A1
686020
200RD2T3TVLC
61-AMG24V
200RD2T3TVLC
61-AMG120/240V
UA1736
RETST601SYS
REWRA630SYS
44-17402-49
RXAD-A08
50313
68-23427-26
SK-A1
686020
200RD2T3TVLC
61-AMG24V
200RD2T3TVLC
61-AMG120/240V
UA1748
RETST601SYS
REWRA630SYS
44-101884-05
RXAD-A08
50313
68-25217-10
SK-A1
686020
200RD3T3TVLC
61-AMG24V
200RD3T3TVLC
61-AMG120/240V
Weighted Sound Power Level (dBA)
Unit Size - Voltage, Series
UA1724A
UA1736A
UA1748A
UA1760A
Standard
Rating (dBA)
72.5
72.3
73.0
76.7
125
48.6
53.1
46.1
58.8
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
250 500 1000 2000 4000
53.7
52.7
62.9
60.9
63.0
62.4
60.5
61.2
57.3
58.4
50.4
60.5
59.5
65.6
64.6
65.2
59.6
62.9
55.8
62.4
UA1760
RETST601SYS
REWRA630SYS
44-101884-05
RXAD-A08
50313
68-25217-10
SK-A1
686020
200RD3T3TVLC
61-AMG24V
200RD3T3TVLC
61-AMG120/240V
8000
54.6
51.6
54.6
55.5
10
Rely on Ruud.™
Smart Home Systems
UA17 Series
Integrated Controls
EcoNet is smart, new technology developed exclusively by Ruud that allows Heating, Cooling, and Water Heating products to communicate with each other on one integrated network.
Easy to Setup, Easy to Use, Easy to Save
• Built with our 360°+1 design philosophy, it is optimized for Installability™, Performance,
Integration & Serviceability
• Controls 65%
† or more of a typical home’s energy use from a single device
• Can reduce energy costs by up to 30% ††
Features
• Added support for new EEV (Electronic
Expansion Valve) Air Handlers, Air Conditioners and Heat Pumps*
• Rapid installation with standard 4-wire configuration
• Automatically configures communicating equipment with optimal settings
• Adapts to home décor through interchangeable faceplates and adjustable background coloring
• Full-color, 4.7" LCD touchscreen display with easy-to-read icons and text
• Convenient date, time and indoor/outdoor temperature indications
• 5 operating modes with short-cycle protection (Heat, Cool, Auto, Emergency Heat,
Fan Only)
• 7-Day programmable schedule with
Smooth Arrival & Whole Home Vacation options
• Detailed operating status, alarm history, and audible alerts
• Supports humidifier accessories or overcool based dehumidification
• One-touch access to Water Heater
Management †††
• Easily manage from anywhere in the world with the compatible WiFi Module & EcoNet app for smart phones and tablets
Warranty
• 5-Year limited warranty from date of
installation
†† † Source – Department of Energy
† †† When compared to non-programmable thermostats.
Source: ENERGY STAR ® for Programmable
Thermostats
††† Requires wired connection to EcoNet Enabled Electric or Hybrid Water Heaters
EcoNet
™
Control Center
Home control with intuitive LCD touchscreen navigation
UETST601SYS
EcoNet Control Center Compatibility
OFFERINGS HEATING & COOLING WATER HEATING
Product
Categories
Gas Furnaces Air Handlers Air Conditioners Heat Pumps
Models
UETST601SYS
U96V U802V RHMV*
RH2T*
(EEV**)
RA20* UASL-JEC RA17 UARL-JEC UP20* UP17* UPRL-JEC
√ √ √ √ √
√
★
√
√
★
√ √
√
★
WiFi Kit for
HVAC
UEWRA630SYS
Electric
Tank
Models
Ending in
EC2
Hybrid
Tank HB50
Models
Gas
Powered
Damper
Tank
Models
√ √ √
*Available in 2015
**Electronic Expansion Valve (EEV) Models
★
Comfort Control
2
System
™
Translator for EcoNet Required
Installation of the RETRN620CC2 Comfort Control 2 System™ Translator on the outdoor unit’s control board is required to operate Comfort Control 2 System™ Air Conditioner and Heat Pump models (****-JEC) with an EcoNet Control Center in a fully communicating mode when matched with EcoNet Enabled Furnaces or Air Handlers*.
Rely on Ruud.™
11
Smart Home Systems
UA17 Series
The EcoNet™ WiFi Kit for Heating & Cooling Systems
(UEWRA630SYS) provides remote control of EcoNet
Enabled air and water products from smart phones, tablets, and personal computers using the home’s internet connection.
Features
• Enables remote operation from:
- The EcoNet App on Apple
(iPhone ® , iPad ® , & iPod ®
® mobile devices
Touch) using iOS version 7.0 or later
- The EcoNet App on Android™ based smart phones and tablets using Android™ version
4.4 or later
- Recent versions of popular web browsers such as Internet Explorer, Chrome, Safari, etc.
• Designed for use with EcoNet communicating HVAC Systems
• Compatible with 802.11 b/g/n WiFi networks
• WPA-2 Security using AES/CCMP
• Status LEDs:
- Power & Equipment
Connection Status
- Home Network WiFi Status
- Internet Connection Status
• “WLAN SETUP" factory reset button
• 24" Port-to-Port Connection Cable
• 1" x 2" Double Adhesive Mounting Tape
• RJ12 Y Splitter (for use with communicating electric water heaters)
Compatibility
• Works with any HVAC System which includes an EcoNet Enabled furnace or air handler and an EcoNet control center.
Warranty
• 1 Year from installation date
WiFi Kit Components
• EcoNet WiFi Module
• Installation Instructions
• V Power Adapter
• Junction Box
EcoNet WiFi Kit for Heating
& Cooling Systems
UEWRA630SYS
HVAC Connection Illustration
12
Rely on Ruud.™
Unit Dimensions
UA17 Series
Unit Dimensions
MODEL
NO.
UA1724
UA1736
UA1748
UA1760
H (Height)
INCHES mm
35
39
51
51
889
990
1295
1295
OPERATING
L (Length)
INCHES mm
33.75
33.75
35.75
35.75
857
857
908
908
W (Width)
INCHES mm
33.75
33.75
35.75
35.75
857
857
908
908
H (Height)
INCHES mm
36.75
40.75
52.75
52.75
933
1035
1339
1339
SHIPPING
L (Length)
INCHES mm
36.38
36.38
38.38
38.38
924
924
974
974
W (Width)
INCHES mm
36.38
36.38
38.38
38.38
924
924
974
974
[ ] Designates Metric Conversions
ST-A1226-02-00
Rely on Ruud.™
13
Clearances
UA17 Series
WALL
14
Rely on Ruud.™
Wiring Diagram/Application Guidelines
UA17 Series
Control Wiring
FIGURE 2
TYPICAL
ECONET COMMUNICATING SYSTEM™
WIRING DIAGRAM
Communicating Thermostat
E1 E2 R C
Outdoor Unit
Indoor Unit
E1
E2
R
C
WIRING INFORMATION
Line Voltage
–Field Installed - - - - - -
–Factory Standard
R
C
E1
E2
Application Guidelines
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
6. Do not apply capillary tube indoor coils to these units.
7. Factory – supplied filter drier must be installed.
Rely on Ruud.™
15
Wiring Diagram/Application Guidelines
UA17 Series
Non-communicating Thermostat Wiring Diagrams
The following figures show the typical wiring diagrams with (-)HPN air handler and (-)ARL condensing unit. Cooling and heat pump airflows may need to be adjusted for homeowner comfort once the system is operational.
WIRE COLOR CODE
BK – BLACK G – GREEN
BR – BROWN GY – GRAY
BL – BLUE
PR – PURPLE Y – YELLOW
R – RED
O – ORANGE W – WHITE
FIGURE 3
TYPICAL 2-STAGE THERMOSTAT: CONDENSING UNIT WITH
ELECTRIC HEAT
Typical Two-Stage Thermostat
Y1
Y2 G W1 W2 C
R
(-)HPN Air
Handler
*
W1
W2
Y1
Y2
R
C
G
ODD
WIRING INFORMATION
Line Voltage
-
Field Installed
Factory Standard
Y
Y/BL
R
BR
W/R
(-)ARL
Condensing
Unit
Y1
Y2
R
C
L
FIGURE 4
TYPICAL TWO-STAGE THERMOSTAT: CONDENSING UNIT WITH
ELECTRIC HEAT USING A HUMIDISTAT FOR DEHUMIDIFICATION*.
Typical Two-Stage Thermostat
Y1 Y2 G
W1 W2
C R
Humidistat
(-)HPN Air
Handler
W1
*
W2
Y1
Y2
R
C
G
ODD
Y
Y/BL
R
BR
W/R
(-)ARL
Condensing
Unit
Y1
Y2
R
C
L
WIRING INFORMATION
Line Voltage
Field Installed
-
Factory Standard
*See Section 5.11 for proper DIP switch selection.
FIGURE 5
TYPICAL TWO-STAGE THERMOSTAT: CONDENSING UNIT WITH
ELECTRIC HEAT USING A TWO-STAGE THERMOSTAT WITH
DEHUMIDIFICATION*
Typical Two-Stage Thermostat
Y1 Y2 G
W1 W2 C
R DHM
(-)HPN Air
Handler
*
W1
W2
Y1
Y2
R
C
G
ODD
Y
Y/BL
R
BR
W/R
(-)ARL
Condensing
Unit
Y1
Y2
R
C
L
WIRING INFORMATION
Line Voltage
-
-
Field Installed
Factory Standard
FIGURE 6
CONDENSING UNIT WITH ELECTRIC HEAT USING A TWO-STAGE
THERMOSTAT WITH DEHUMIDIFICATION*
(-)HPN Air
Handler
*
W1
W2
Y1
Y2
R
C
G
ODD
WIRING INFORMATION
Line Voltage
Field Installed
-
Factory Standard
Typical Two-Stage Thermostat
Y1 Y2 G
W1 W2
C R DHM L
Y
Y/BL
R
BR
W/R
(-)ARL
Condensing
Unit
Y1
Y2
R
C
L
*If maximum outlet temperature rise is desired, it is recommended that W1 and W2 be jumpered together.
Application Guidelines
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
6. Do not apply capillary tube indoor coils to these units.
7. Factory – supplied filter drier must be installed.
16
Rely on Ruud.™
Refrigerant Line Size Information
UA17 Series
Rely on Ruud.™
17
Refrigerant Line Size Information
UA17 Series
18
Rely on Ruud.™
Performance Data
UA17 Series
Performance Data @ AHRI Standard Conditions – Cooling
High Sales Volume Tested Combination (HSVTC)
Outdoor Unit
Indoor Coil or Air Handler
Total Capacity
BTU/H [kW]
UA1724AJ2
UA1736AJ2
UA1748AJ2
UA1760AJ2
RH2T2421MEAC
RH2T3621MEAC
RH2T4821MEAC
RH2T6024MEAC
24000 [7.0]
36000 [10.6]
47000 [13.8]
56000 [16.4]
Net Sensible
BTU/H [kW]
17100 [5.0]
26000 [7.6]
34000 [10.0]
39300 [11.5]
Net Latent
BTU/H [kW]
6900 [2.0]
10000 [2.9]
13000 [3.8]
16700 [4.9]
SEER
17.00
17.00
17.00
16.00
EER
13.00
13.00
13.00
12.50
Indoor
CFM [L/s]
700 [330.4]
1050 [495.5]
1400 [660.7]
1550 [731.5]
AHRI#
8231639
8231642
8231644
8231646
Coil Only Ratings
Outdoor Unit
UA1724AJ2
UA1736AJ2
UA1748AJ2
UA1760AJ2
Indoor Coil
RCF2421MEAM+RXMD-C04
RCF3621MEAM+RXMD-C04
RCF6021SEAM+RXMD-C04
RCF6021SEAM+RXMD-C04
RCF6024MEAM+RXMD-C04
Total Capacity
BTU/H [kW]
24000 [7.0]
36000 [10.6]
36000 [10.6]
48000 [14.1]
55500 [16.3]
Net Sensible
BTU/H [kW]
17100 [5.0]
26000 [7.6]
26000 [7.6]
34600 [10.1]
38100 [11.2]
Net Latent
BTU/H [kW]
6900 [2.0]
10000 [2.9]
10000 [2.9]
13400 [3.9]
17400 [5.1]
SEER
15.10
15.10
15.50
15.50
14.50
EER
12.50
12.50
12.50
12.50
11.70
Indoor
CFM [L/s]
800 [377.6]
1200 [566.3]
1200 [566.3]
1550 [731.5]
1600 [755.1]
AHRI#
8234324
8231640
8231641
8231643
8231645
U802V: Ultra 2-Stage 80% ECM Furnace Ratings
Outdoor Unit
UA1724AJ2
UA1724AJ2
UA1724AJ2
UA1736AJ2
UA1736AJ2
UA1736AJ2
UA1736AJ2
UA1736AJ2
UA1748AJ2
UA1748AJ2
UA1748AJ2
UA1760AJ2
UA1760AJ2
UA1760AJ2
UA1760AJ2
UA1760AJ2
UA1760AJ2
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
U802VA050317MSA RCF2421MEAM 24000 [7.0] 17100 [5.0]
U802VA075317MSA RCF2421MEAM 24000 [7.0] 17100 [5.0]
U802VA075317ZSA RCF2421MEAM 24000 [7.0] 17100 [5.0]
U802VA075317MSA
6900 [2.0]
6900 [2.0]
6900 [2.0]
RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
U802VA075317ZSA
U802VA075421ZSA
RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
U802VA100521MSA
U802VA100521ZSA
RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
U802VA075421ZSA RCF6021SEAM
U802VA100521MSA RCF6021SEAM
U802VA100521ZSA RCF6021SEAM
47500 [13.9] 35400 [10.4] 12100 [3.5]
48000 [14.1] 35800 [10.5] 12200 [3.6]
47000 [13.8] 33900 [9.9] 13100 [3.8]
U802VA075421MSA RCF6024MEAM 55000 [16.1] 37300 [10.9] 17700 [5.2]
U802VA075421ZSA RCF6021SEAM 54000 [15.8] 37200 [10.9] 16800 [4.9]
RCF6021SEAM 55000 [16.1] 39200 [11.5] 15800 [4.6]
U802VA100521MSA
RCF6024MEAM 55500 [16.3] 38800 [11.4] 16700 [4.9]
RCF6021SEAM 54000 [15.8] 36900 [10.8] 17100 [5.0]
U802VA100521ZSA
RCF6024MEAM 55500 [16.3] 38700 [11.3] 16800 [4.9]
U802VA125524MSA RCF6024MEAM 55500 [16.3] 38800 [11.4] 16700 [4.9]
U802VA125524ZSA RCF6024MEAM 55500 [16.3] 38800 [11.4] 16700 [4.9]
SEER
17.00
17.00
17.00
17.00
17.00
16.50
17.00
17.00
17.00
17.00
17.00
17.00
17.00
17.00
17.00
17.00
16.00
15.50
16.00
16.00
15.50
16.00
16.00
16.00
[ ] Designates Metric Conversions
EER
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
12.50
13.00
13.00
12.50
11.70
12.00
12.50
12.00
12.00
12.50
12.00
AHRI#
8234319
8234320
8234321
8232069
8232078
8232070
8232079
8232071
8232080
8232072
8232081
8232073
8232082
8232087
8232088
8232089
8232096
8232092
8232093
8232097
8232094
8232098
8232099
8232100
Indoor
CFM [L/s]
725 [342.2]
675 [318.6]
725 [342.2]
1075 [507.3]
1075 [507.3]
1050 [495.5]
1050 [495.5]
1075 [507.3]
1075 [507.3]
1025 [483.7]
1025 [483.7]
1050 [495.5]
1050 [495.5]
1550 [731.5]
1525 [719.7]
1400 [660.7]
1425 [672.5]
1600 [755.1]
1725 [814.1]
1575 [743.3]
1550 [731.5]
1550 [731.5]
1575 [743.3]
1575 [743.3]
Rely on Ruud.™
19
Performance Data
UA17 Series
Performance Data @ AHRI Standard Conditions – Cooling (con’t.)
U96V: 96% AFUE 2-stage Variable Speed Multipoise Gas Furnace Uatings
Outdoor Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
UA1724AJ2
UA1724AJ2
Net Sensible
BTU/H [kW]
U96VA0602317MSA RCF2421MEAM 24000 [7.0] 17100 [5.0]
UA1736AJ2
Net Latent
BTU/H [kW]
6900 [2.0]
U96VA0702317MSA RCF2421MEAM 24000 [7.0] 17100 [5.0] 6900 [2.0]
RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
U96VA0602317MSA
RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
UA1736AJ2
UA1736AJ2
U96VA0702317MSA
U96VA0852521MSB
RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
UA1736AJ2
UA1748AJ2
UA1748AJ2
UA1760AJ2
UA1760AJ2
UA1760AJ2
U96VA1002521MSA
RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]
U96VA0852521MSB RCF6021SEAM 47500 [13.9] 35400 [10.4] 12100 [3.5]
U96VA1002521MSA RCF6021SEAM 47500 [13.9] 35400 [10.4] 12100 [3.5]
U96VA0852521MSB RCF6024MEAM 55000 [16.1] 38200 [11.2] 16800 [4.9]
RCF6021SEAM 53000 [15.5] 34800 [10.2] 18200 [5.3]
U96VA1002521MSA
RCF6024MEAM 55000 [16.1] 38200 [11.2] 16800 [4.9]
U96VA1152524MSA RCF6024MEAM 54500 [16.0] 36700 [10.8] 17800 [5.2]
SEER
17.00
17.00
16.50
17.00
16.50
17.00
16.50
17.00
17.00
17.00
17.00
17.00
15.50
15.50
15.50
16.00
EER
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
12.50
12.50
12.00
12.00
12.00
12.50
Indoor
CFM [L/s]
775 [365.8]
700 [330.4]
1050 [495.5]
1050 [495.5]
1050 [495.5]
1050 [495.5]
1075 [507.3]
1075 [507.3]
1050 [495.5]
1050 [495.5]
1550 [731.5]
1550 [731.5]
1550 [731.5]
1400 [660.7]
1550 [731.5]
1400 [660.7]
AHRI#
8234322
8234323
8232074
8232083
8232075
8232084
8232076
8232085
8232077
8232086
8232090
8232091
8232101
8232095
8232102
8232103
[ ] Designates Metric Conversions
20
Rely on Ruud.™
Guide Specifications
UA17 Series
GUIDE SPECIFICATIONS
General
System Description
Outdoor-mounted, air-cooled, split-system air conditioner composite base pan unit suitable for ground or rooftop installation.
Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser fan, suction and legend line service valve, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a coil unit.
Quality Assurance
— Unit will be rated in accordance with the latest edition of AHRI
Standard 210.
— Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory.
— Unit construction will comply with latest edition of ANSI/
ASHRAE and with NEC.
— Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval.
— Unit cabinet will be capable of withstanding ASTM B117 1000hr salt spray test.
— Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 550 psig.
— Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
— Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
— U.S. and
Canada only.
Products
Equipment
Factory assembled, single piece, air-cooled air conditioner unit.
Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge R-410A, and special features required prior to field start-up.
Unit Cabinet
— Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint.
— All units constructed with louver coil protection and corner post.
Louver can be removed by removing one fastener per louver panel.
AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER
UA17
1-1/2 TO 5 NOMINAL TONS
Fans
— Condenser fan will be direct-drive propeller type, discharging air upward.
— Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings.
Shafts will be corrosion resistant.
— Fan blades will be statically and dynamically balanced.
— Condenser fan openings will be equipped with coated steel wire safety guards.
Compressor
— Compressor will be hermetically sealed.
— Compressor will be mounted on rubber vibration isolators.
Condenser Coil
— Condenser coil will be air cooled.
— Coil will be constructed of aluminum fins mechanically bonded to copper tubes.
Refrigeration Components
— Refrigeration circuit components will include liquid-line shutoff valve with sweat connections, vapor-line shutoff valve with sweat connections, system charge of R-410A refrigerant, and compressor oil.
— Unit will be equipped with filter drier for R-410A refrigerant for field installation.
Operating Characteristics
— The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ °F/°C. The power consumption at full load will not exceed _____ kW.
— Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ °F/°C wet bulb and _____ °F/°C dry bulb, and air entering the unit at _____ °F/°C.
— The system will have a SEER of _____ Btuh/watt or greater at
DOE conditions.
Electrical Requirements
— Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v.
— Nominal unit electrical characteristics will be _____ v, three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v.
— Unit electrical power will be single point connection.
— Control circuit will be 24v.
Special Features
— Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.
Rely on Ruud.™
21
Limited Warranty
UA17 Series
GENERAL TERMS OF LIMITED WARRANTY*
Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the
Manufacturer for a copy of the product warranty certificate.
Conditional Unit Replacement
(Registration Required) ...............................Ten (10) Years
Parts ............................................................Ten (10) Years
22
Rely on Ruud.™
Notes
UA17 Series
Rely on Ruud.™
23
In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.
Ruud Heating, Cooling & Water Heating • P.O. Box 17010
Fort Smith, Arkansas 72917 • www.ruud.com
Ruud Canada • 125 Edgeware Road, Unit 1
Brampton, Ontario • L6Y 0P5
PRINTED IN U.S.A. 11/15 QG FORM NO. A22-223 REV. 3
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Standard Feature
- 3 Available SKUs
- 4 Features & Benefits
- 7 Model Number Identification
- 9 General Data/Electrical Data
- 10 Accessories
- 10 Weighted Sound Power
- 11 Smart Home Systems
- 13 Unit Dimensions
- 14 Clearances
- 15 Wiring Diagrams
- 15 Application Guidelines
- 17 Refrigerant Line Size Information
- 19 Performance Data
- 21 Guide Specifications
- 22 Limited Warranty