Ruud UA1724A, UA1736A, UA1748A, UA1760A Manual


Add to my manuals
24 Pages

advertisement

Ruud UA1724A, UA1736A, UA1748A, UA1760A Manual | Manualzz

Ruud Achiever Plus

Series

Two-Stage Air Conditioners

Air Conditioners

UA17 Series

UA17 Series

Efficiencies up to 17 SEER/13 EER

Nominal Sizes 2, 3, 4 & 5 Ton

[7.03, 10.6, 14.06 & 17.6 kW]

Cooling Capacities 17.3 to 60.5 kBTU

[5.7 to 17.7 kW]

Seasonal Energy Efficiency Ratio -

SEER

THIS MODEL

17.00

10.0

17.0

USES LESS ENERGY

“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star.

Ask your Contractor for details or visit www.energystar.gov.”

• EcoNet ™ Enabled product. The EcoNet Smart Home System provides advanced air & water control for maximum energy savings and ideal comfort.

• New composite base pan – dampens sound, captures louver panels, eliminates corrosion and reduces number of fasteners needed

• Powder coat paint system – for a long lasting professional finish

• The Two Stage Copeland Scroll ™ UltraTech ™ Compressor modulates between two capacity settings – 67% and

100% – providing more precise temperature control, lower humidity and greater efficiency in comparison to single stage compressors. It uses 70% fewer moving parts which also increases efficiency and reliability.

• Modern cabinet aesthetics – increased curb appeal with visually appealing design

• Curved louver panels – provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity

• Optimized fan orifice – optimizes airflow and reduces unit sound

• Rust resistant screws – confirmed through 1500-hour salt spray testing

• PlusOne™

Expanded Valve Space

– 3"-4"-5" service valve space – provides a minimum working area of 27-square inches for easier access

• PlusOne™

Triple Service Access

– 15" wide, industry leading corner service access – makes repairs easier and faster.

The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly

• Diagnostic service window with two-fastener opening –

provides access to the high and low pressure.

• External gauge port access – allows easy connection of

“low-loss” gauge ports

• Single-row condenser coil – makes unit lighter and allows

thorough coil cleaning to maintain “out of the box” performance

• 35% fewer cabinet fasteners and fastener-free base – allow for faster access to internal components and hassle-free panel removal

• Service trays – hold fasteners or caps during service calls

• QR code – provides technical information on demand for faster service calls

• Fan motor harness with extra long wires allows unit top to be removed without disconnecting fan wire.

• High and low pressure standard on all models.

Rely on Ruud.™

FORM NO. A22-223 REV. 3

Table of Contents

UA17 Series

Standard Feature ......................................................................................................3

Available SKUs ........................................................................................................3

Features & Benefits ..............................................................................................4-6

Model Number Identification ................................................................................7-8

General Data/Electrical Data ....................................................................................9

Accessories ..........................................................................................................10

Weighted Sound Power ..........................................................................................10

Smart Home Systems ......................................................................................11-12

Unit Dimensions......................................................................................................13

Clearances ..............................................................................................................14

Wiring Diagrams ................................................................................................15-16

Application Guidelines ......................................................................................15-16

Refrigerant Line Size Information ......................................................................17-18

Performance Data ............................................................................................19-20

Guide Specifications ..............................................................................................21

Limited Warranty ....................................................................................................22

2

Rely on Ruud.™

Standard Feature/Available SKUs

UA17 Series

Standard Feature Table

Feature

R-410A Refrigerant

Maximum SEER

Maximum EER

EcoNet Enabled

Two Stage Copeland Scroll ™ UltraTech ™ Compressor

Field Installed Filter Drier

Front Seating Service Valves

Internal Pressure Relief Valve

Internal Thermal Overload

Long Line capability

Low Ambient capability with Kit

3-4-5 Expanded Valve Space

Composite Basepan

2 Screw Control Box Access

15" Access to Internal Components

Quick release louver panel design

No fasteners to remove along bottom

Optimized Venturi Airflow

Single row condenser coil

Powder coated paint

Rust resistant screws

QR code

External gauge ports

Service trays

√ = Standard

Available SKUs

Available Models

UA1724AJ2CB

UA1736AJ2CB

UA1748AJ2CB

UA1760AJ2CB

24

STANDARD FEATURES

17

13

36

17

13

48

17

13

Description

Achiever Plus

™ Series 2 ton 17 SEER Two Stage Air Conditioner-208/230/1/60

Achiever Plus ™ Series 3 ton 17 SEER Two Stage Air Conditioner-208/230/1/60

Achiever Plus ™ Series 4 ton 17 SEER Two Stage Air Conditioner-208/230/1/60

Achiever Plus

™ Series 5 ton 17 SEER Two Stage Air Conditioner-208/230/1/60

60

16

12.5

Rely on Ruud.™

3

Features & Benefits

UA17 Series

Introduction to UA17 Air Conditioner

The UA17 is our EcoNet Enabled 17 SEER Two-Stage Air Conditioner and is part of the Ruud Air Conditioner product line that extends from 13 to 20 SEER. This highly featured and reliable air conditioner is designed for years of reliable, efficient operation when matched with Ruud indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators.

The UA17 is exclusively designed to operate with the EcoNet

Smart Home System. Developed by Ruud, The EcoNet Smart

Home System allows homeowners to manage select highefficiency, EcoNet Enabled air conditioners, heat pumps, gas furnaces, air handlers and water heaters from anywhere.

EcoNet Enabled products in a home are connected through standard HVAC wiring; then, contractors have the option of adding an EcoNet WiFi kit (

1

) so the homeowner can access everything remotely through a free mobile app or mobile-friendly website. The Control Center (

2

) acts as both a thermostat for the heating and cooling system, and a remote control for connected water heaters.

1 2

Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover, revealing the industry’s largest 15" wide and 14" tall control area (

10

). With all this room in the control area the high voltage electrical whip (

11

) can easily be inserted through the right size opening in the

bottom of the control area. Routing it leads directly to contractor lugs for connection. The low voltage control wires (

12

) are easily connected to the units low voltage wiring. If contactor or capacitor (

13

) needs to be replaced there is more than adequate space to make the repair. The service window (

14

) can be removed by removing two screws, to access the high and low pressure switches and view interior of unit. (

15

) (High and low pressure is standard on UA17 models).

14

The EcoNet Smart Home System is the first integrated system for a home’s Heating, Cooling and Water Heating equipment – allowing homeowners to manage the products that consume up to 65% of their home’s energy. EcoNet sets Ruud, our distributor and contactor customers apart in the industry with a unique, advanced and efficient technology solution.

3

10

12

13

11

15

If in the rare event, greater access is needed to internal components, such as the compressor, the entire corner of the unit can be removed along with the top cover assembly to have unprecedented access to interior of the unit (

16

). Extra wire length is incorporated into each outdoor fan and compressor so top cover and control panel can be positioned next to the unit. With minimal effort the plug can be removed from the compressor and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit (

17

).

Outdoor coil heights range from as short as 35" to 51". Disassembly to this degree and complete reassembly only takes a first time service technician less than 10 minutes. (

17

)

20

18

4

6

6

8

5 7

Our unique composite base (

3

) reduces sound emission, eliminates rattles, significantly reduces fasteners, eliminates corrosion and has integrated brass compressor attachment inserts (

4

).

Furthermore it has incorporated into the design, water manage ment features, means for hand placement (

5

) for unit maneuvering, screw trays (

6

) and inserts for lifting off unit pad. (

7

)

Service Valves (

8

) are rigidly mounted in the composite base with 3" between suction and discharge valves, 4" clearance below service valves and a minimum of 5" above the service valves, creating industry leading ease of installation. The minimum

9

16

All units utilize strong formed louver panels which provide industry leading coil protection. Louver removal for coil cleaning is accomplished by removing one screw and lifting the panel out of the composite base pan. (

19

) All UA17 units utilize single row coils (

18

) making cleaning easy and complete, restoring the performance of the air conditioner back to out of the box performance levels year after year.

17

19

27 square-inches around the service valves allows ample room to remove service valve schrader prior to brazing, plenty of clearance for easy brazing of the suction and discharge lines to service valve outlets, easy access and hookup of low loss refrigerant gauges (

9

), and access to the service valve caps for opening. For applications with long-line lengths up to 250 feet total equivalent length, up to 200 feet condenser above evaporator, or up to 80 feet evaporator above condenser, the long-line instructions in the installation manual should be followed.

4

Rely on Ruud.™

The outdoor fan motor has sleeve bearings and is inherently protected. The motor is totally enclosed for maximum protection from weather, dust and corrosion. (

20

) Access to the outdoor fan is made by removing four fasteners from the fan grille. The outdoor fan can be removed from the fan grille by removing 4 fasteners in the rare case outdoor fan motor fails.

Each cabinet has optimized composite (

21

) fan orifice assuring efficient and quiet airflow.

21

The entire cabinet has post powder paint (

22

) achieving 1000 hour salt spray rating, allowing the cabinet to retain its aesthetics throughout its life.

26

22

25

24

23

Two Stage Copeland Scroll

UltraTech

™ compressors with

standard internal pressure relief and internal thermal overload are used on all capacities assuring longevity of high efficient and quiet operation for the life of the product.

All models come standard with high and low pressure controls.

Each unit is shipped with filter drier for field installation and will trap any moisture or dirt that could contaminate the refrigerant system.

27

All cabinets have industry leading structural strength due to the composite base pan (

23

), interlocking corner post (

24

), formed curved louver panels (

25

) and drawn top cover (

26

) making it the most durable cabinet on the market today.

Each UA17 capacity has undergone rigorous psychometric testing to assure performance ratings of capacity, SEER and EER per AHRI Standard 210/240 rating conditions. Also each unit bears the UL mark and each unit is certified to UL 1995 safety standards.

Each unit has undergone specific strain and modal testing to assure tubing (

27

) is outside the units natural frequency and that the suction and discharge lines connected to the compressor withstand any starting, steady state operation, or shut down forces imposed by the compressor.

Features & Benefits

UA17 Series

All units have been sound tested in sound chamber to AHRI 270 rating conditions, and A-weighted Sound Power Level tables produced, assuring units have acceptable noise qualities (see page 10). Each unit has been ran in cooling operation at 95°F and 82°F and sound ratings for the UA17 range from as low as

72.3 dBA to 76.7 dBA.

All units have been ship tested to assure units meet stringent

“over the road” shipping conditions.

As manufactured, all units in the UA17 family have cooling capability to 55 °F. Addition of low ambient control will allow the unit to operate down to 0°F. Factory testing is performed on each unit. All component parts meet well defined specification and continually go through receiving inspections. Each component installed on a unit is scanned, assuring correct component utilization for a given unit capacity and voltage. All condenser coils are leak tested with pressurization test to 550#’s and once installed and assembled, each units’ complete refrigerant

system is helium leak tested. All units are fully charged from the factory for up to 15 feet of piping. All units are factory run tested.

The UA17 has a 10-year conditional unit replacement warranty

(registration required) and a 10 year limited parts warranty.

Optional Accessories

(Refer to accessory chart for model #)

Compressor Crankcase Heater

Protects against refrigerant migration that can occur during low ambient operation

Compressor Sound Cover

• Reinforced vinyl compressor cover containing a 1½ inch thick batt of fiberglass insulation

• Open edges are sealed with a one-inch wide hook and loop fastening tape

Compressor Hard Start Kit

• Single-phase units are equipped with a PSC compressor motor, this type of motor normally does not need a potential relay and start capacitor

• Kit may be required to increase the compressor starting torque, in conditions such as low voltage

Low Ambient Kit

• Air conditioners operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional controls

• This Kit can be added in the field enabling unit to operate properly down to 0° in the cooling mode

• Crankcase heater and freezestat should be installed on compressors equipped with a low ambient kit

3"/6"/12"

• Gray high density polyethylene feet are available to raise unit off of mounting surface away from moisture

Decorative Top

• Can be installed on fan grille

Rely on Ruud.™

5

Features & Benefits

UA17 Series

Accessories

EcoNet Control Center

The EcoNet Control Center serves as the hub of communication for a home’s Heating, Cooling and

Water Heating systems, and is required to operate an EcoNet

Enabled Heating & Cooling system in a fully communicating mode.

UETST601SYS

WiFi Kit for Heating and Cooling Systems

The WiFi kit is required to remotely operate EcoNet Enabled

Heating and Cooling Systems from the EcoNet Web portal and mobile apps.

UEWRA630SYS

6

Rely on Ruud.™

Model Number Identification

UA17 Series

Rely on Ruud.™

7

Model Number Identification

UA17 Series

8

Rely on Ruud.™

General Data/Electrical Data

UA17 Series

Physical Data

Model No.

Nominal Tonnage

Valve Connections

UA1724A

2.0

UA1736A

3.0

UA1748A

4.0

UA1760A

5.0

Liquid Line O.D. – in.

Suction Line O.D. – in.

3/8

3/4

128

3/8

3/4

151

3/8

7/8

204

3/8

7/8

223

Refrigerant (R-410A) furnished oz.¹

Compressor Type

Outdoor Coil

Scroll

Net face area – Outer Coil

Net face area – Inner Coil

Tube diameter – in.

Number of rows

Fins per inch

19.8

0.375

1

20

22.2

0.375

1

22

32.3

0.375

1

22

32.3

0.375

1

22

Outdoor Fan

Shipping weight – lbs.

Operating weight – lbs.

Diameter – in.

Number of blades

Motor hp

CFM

RPM watts

24

3

1/5

3326

850

112

200

193

24

3

1/5

3540

820

112

209

202

26

3

1/2

4251

646

132

297

290

26

3

1/2

5133

825

113

298

291

Electrical Data

Line Voltage Data (Volts-Phase-Hz)

Maximum overcurrent protection (amps)²

Minimum circuit ampacity³

Compressor

208/230-1-60

25

16

208/230-1-60

35

21

208/230-1-60

50

32

208/230-1-60

70

42

Rated load amps

Locked rotor amps

11.7

58.3

15.3

83

21.2

104

28.8

152.9

Condenser Fan Motor

Full load amps

Locked rotor amps

1.4

1.2

5.3

5.3

¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.

²HACR type circuit breaker of fuse.

³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.

Rely on Ruud.™

9

Accessories/Weighted Sound Power

UA17 Series

Accessories

Model No.

EcoNet Control Center

WiFi Kit for Heating & Cooling

Compressor crankcase heater*

Low ambient control

Freeze Stat

Compressor sound cover

Compressor hard start kit

Heat pump Riser 6 in.

Liquid Line Solenoid

(24 VAC, 50/60 Hz)

Liquid Line Solenoid

(120/240 VAC, 50/60 Hz)

Solenoid Valve

Solenoid Coil

Solenoid Valve

Solenoid Coil

*Crankcase Heater recommended with Low Ambient Kit.

UA1724

RETST601SYS

REWRA630SYS

44-17402-49

RXAD-A08

50313

68-23427-26

SK-A1

686020

200RD2T3TVLC

61-AMG24V

200RD2T3TVLC

61-AMG120/240V

UA1736

RETST601SYS

REWRA630SYS

44-17402-49

RXAD-A08

50313

68-23427-26

SK-A1

686020

200RD2T3TVLC

61-AMG24V

200RD2T3TVLC

61-AMG120/240V

UA1748

RETST601SYS

REWRA630SYS

44-101884-05

RXAD-A08

50313

68-25217-10

SK-A1

686020

200RD3T3TVLC

61-AMG24V

200RD3T3TVLC

61-AMG120/240V

Weighted Sound Power Level (dBA)

Unit Size - Voltage, Series

UA1724A

UA1736A

UA1748A

UA1760A

Standard

Rating (dBA)

72.5

72.3

73.0

76.7

125

48.6

53.1

46.1

58.8

NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)

TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)

250 500 1000 2000 4000

53.7

52.7

62.9

60.9

63.0

62.4

60.5

61.2

57.3

58.4

50.4

60.5

59.5

65.6

64.6

65.2

59.6

62.9

55.8

62.4

UA1760

RETST601SYS

REWRA630SYS

44-101884-05

RXAD-A08

50313

68-25217-10

SK-A1

686020

200RD3T3TVLC

61-AMG24V

200RD3T3TVLC

61-AMG120/240V

8000

54.6

51.6

54.6

55.5

10

Rely on Ruud.™

Smart Home Systems

UA17 Series

Integrated Controls

EcoNet is smart, new technology developed exclusively by Ruud that allows Heating, Cooling, and Water Heating products to communicate with each other on one integrated network.

Easy to Setup, Easy to Use, Easy to Save

• Built with our 360°+1 design philosophy, it is optimized for Installability™, Performance,

Integration & Serviceability

• Controls 65%

† or more of a typical home’s energy use from a single device

• Can reduce energy costs by up to 30% ††

Features

• Added support for new EEV (Electronic

Expansion Valve) Air Handlers, Air Conditioners and Heat Pumps*

• Rapid installation with standard 4-wire configuration

• Automatically configures communicating equipment with optimal settings

• Adapts to home décor through interchangeable faceplates and adjustable background coloring

• Full-color, 4.7" LCD touchscreen display with easy-to-read icons and text

• Convenient date, time and indoor/outdoor temperature indications

• 5 operating modes with short-cycle protection (Heat, Cool, Auto, Emergency Heat,

Fan Only)

• 7-Day programmable schedule with

Smooth Arrival & Whole Home Vacation options

• Detailed operating status, alarm history, and audible alerts

• Supports humidifier accessories or overcool based dehumidification

• One-touch access to Water Heater

Management †††

• Easily manage from anywhere in the world with the compatible WiFi Module & EcoNet app for smart phones and tablets

Warranty

• 5-Year limited warranty from date of

installation

†† † Source – Department of Energy

† †† When compared to non-programmable thermostats.

Source: ENERGY STAR ® for Programmable

Thermostats

††† Requires wired connection to EcoNet Enabled Electric or Hybrid Water Heaters

EcoNet

Control Center

Home control with intuitive LCD touchscreen navigation

UETST601SYS

EcoNet Control Center Compatibility

OFFERINGS HEATING & COOLING WATER HEATING

Product

Categories

Gas Furnaces Air Handlers Air Conditioners Heat Pumps

Models

UETST601SYS

U96V U802V RHMV*

RH2T*

(EEV**)

RA20* UASL-JEC RA17 UARL-JEC UP20* UP17* UPRL-JEC

√ √ √ √ √

√ √

WiFi Kit for

HVAC

UEWRA630SYS

Electric

Tank

Models

Ending in

EC2

Hybrid

Tank HB50

Models

Gas

Powered

Damper

Tank

Models

√ √ √

*Available in 2015

**Electronic Expansion Valve (EEV) Models

Comfort Control

2

System

Translator for EcoNet Required

Installation of the RETRN620CC2 Comfort Control 2 System™ Translator on the outdoor unit’s control board is required to operate Comfort Control 2 System™ Air Conditioner and Heat Pump models (****-JEC) with an EcoNet Control Center in a fully communicating mode when matched with EcoNet Enabled Furnaces or Air Handlers*.

Rely on Ruud.™

11

Smart Home Systems

UA17 Series

The EcoNet™ WiFi Kit for Heating & Cooling Systems

(UEWRA630SYS) provides remote control of EcoNet

Enabled air and water products from smart phones, tablets, and personal computers using the home’s internet connection.

Features

• Enables remote operation from:

- The EcoNet App on Apple

(iPhone ® , iPad ® , & iPod ®

® mobile devices

Touch) using iOS version 7.0 or later

- The EcoNet App on Android™ based smart phones and tablets using Android™ version

4.4 or later

- Recent versions of popular web browsers such as Internet Explorer, Chrome, Safari, etc.

• Designed for use with EcoNet communicating HVAC Systems

• Compatible with 802.11 b/g/n WiFi networks

• WPA-2 Security using AES/CCMP

• Status LEDs:

- Power & Equipment

Connection Status

- Home Network WiFi Status

- Internet Connection Status

• “WLAN SETUP" factory reset button

• 24" Port-to-Port Connection Cable

• 1" x 2" Double Adhesive Mounting Tape

• RJ12 Y Splitter (for use with communicating electric water heaters)

Compatibility

• Works with any HVAC System which includes an EcoNet Enabled furnace or air handler and an EcoNet control center.

Warranty

• 1 Year from installation date

WiFi Kit Components

• EcoNet WiFi Module

• Installation Instructions

• V Power Adapter

• Junction Box

EcoNet WiFi Kit for Heating

& Cooling Systems

UEWRA630SYS

HVAC Connection Illustration

12

Rely on Ruud.™

Unit Dimensions

UA17 Series

Unit Dimensions

MODEL

NO.

UA1724

UA1736

UA1748

UA1760

H (Height)

INCHES mm

35

39

51

51

889

990

1295

1295

OPERATING

L (Length)

INCHES mm

33.75

33.75

35.75

35.75

857

857

908

908

W (Width)

INCHES mm

33.75

33.75

35.75

35.75

857

857

908

908

H (Height)

INCHES mm

36.75

40.75

52.75

52.75

933

1035

1339

1339

SHIPPING

L (Length)

INCHES mm

36.38

36.38

38.38

38.38

924

924

974

974

W (Width)

INCHES mm

36.38

36.38

38.38

38.38

924

924

974

974

[ ] Designates Metric Conversions

ST-A1226-02-00

Rely on Ruud.™

13

Clearances

UA17 Series

WALL

14

Rely on Ruud.™

Wiring Diagram/Application Guidelines

UA17 Series

Control Wiring

FIGURE 2

TYPICAL

ECONET COMMUNICATING SYSTEM™

WIRING DIAGRAM

Communicating Thermostat

E1 E2 R C

Outdoor Unit

Indoor Unit

E1

E2

R

C

WIRING INFORMATION

Line Voltage

–Field Installed - - - - - -

–Factory Standard

R

C

E1

E2

Application Guidelines

1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.

2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).

3. Maximum outdoor operating air temperature is 125°F (51.7°C).

4. For reliable operation, unit should be level in all horizontal planes.

5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.

6. Do not apply capillary tube indoor coils to these units.

7. Factory – supplied filter drier must be installed.

Rely on Ruud.™

15

Wiring Diagram/Application Guidelines

UA17 Series

Non-communicating Thermostat Wiring Diagrams

The following figures show the typical wiring diagrams with (-)HPN air handler and (-)ARL condensing unit. Cooling and heat pump airflows may need to be adjusted for homeowner comfort once the system is operational.

WIRE COLOR CODE

BK – BLACK G – GREEN

BR – BROWN GY – GRAY

BL – BLUE

PR – PURPLE Y – YELLOW

R – RED

O – ORANGE W – WHITE

FIGURE 3

TYPICAL 2-STAGE THERMOSTAT: CONDENSING UNIT WITH

ELECTRIC HEAT

Typical Two-Stage Thermostat

Y1

Y2 G W1 W2 C

R

(-)HPN Air

Handler

*

W1

W2

Y1

Y2

R

C

G

ODD

WIRING INFORMATION

Line Voltage

-

Field Installed

Factory Standard

Y

Y/BL

R

BR

W/R

(-)ARL

Condensing

Unit

Y1

Y2

R

C

L

FIGURE 4

TYPICAL TWO-STAGE THERMOSTAT: CONDENSING UNIT WITH

ELECTRIC HEAT USING A HUMIDISTAT FOR DEHUMIDIFICATION*.

Typical Two-Stage Thermostat

Y1 Y2 G

W1 W2

C R

Humidistat

(-)HPN Air

Handler

W1

*

W2

Y1

Y2

R

C

G

ODD

Y

Y/BL

R

BR

W/R

(-)ARL

Condensing

Unit

Y1

Y2

R

C

L

WIRING INFORMATION

Line Voltage

Field Installed

-

Factory Standard

*See Section 5.11 for proper DIP switch selection.

FIGURE 5

TYPICAL TWO-STAGE THERMOSTAT: CONDENSING UNIT WITH

ELECTRIC HEAT USING A TWO-STAGE THERMOSTAT WITH

DEHUMIDIFICATION*

Typical Two-Stage Thermostat

Y1 Y2 G

W1 W2 C

R DHM

(-)HPN Air

Handler

*

W1

W2

Y1

Y2

R

C

G

ODD

Y

Y/BL

R

BR

W/R

(-)ARL

Condensing

Unit

Y1

Y2

R

C

L

WIRING INFORMATION

Line Voltage

-

-

Field Installed

Factory Standard

FIGURE 6

CONDENSING UNIT WITH ELECTRIC HEAT USING A TWO-STAGE

THERMOSTAT WITH DEHUMIDIFICATION*

(-)HPN Air

Handler

*

W1

W2

Y1

Y2

R

C

G

ODD

WIRING INFORMATION

Line Voltage

Field Installed

-

Factory Standard

Typical Two-Stage Thermostat

Y1 Y2 G

W1 W2

C R DHM L

Y

Y/BL

R

BR

W/R

(-)ARL

Condensing

Unit

Y1

Y2

R

C

L

*If maximum outlet temperature rise is desired, it is recommended that W1 and W2 be jumpered together.

Application Guidelines

1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.

2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).

3. Maximum outdoor operating air temperature is 125°F (51.7°C).

4. For reliable operation, unit should be level in all horizontal planes.

5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.

6. Do not apply capillary tube indoor coils to these units.

7. Factory – supplied filter drier must be installed.

16

Rely on Ruud.™

Refrigerant Line Size Information

UA17 Series

Rely on Ruud.™

17

Refrigerant Line Size Information

UA17 Series

18

Rely on Ruud.™

Performance Data

UA17 Series

Performance Data @ AHRI Standard Conditions – Cooling

High Sales Volume Tested Combination (HSVTC)

Outdoor Unit

Indoor Coil or Air Handler

Total Capacity

BTU/H [kW]

UA1724AJ2

UA1736AJ2

UA1748AJ2

UA1760AJ2

RH2T2421MEAC

RH2T3621MEAC

RH2T4821MEAC

RH2T6024MEAC

24000 [7.0]

36000 [10.6]

47000 [13.8]

56000 [16.4]

Net Sensible

BTU/H [kW]

17100 [5.0]

26000 [7.6]

34000 [10.0]

39300 [11.5]

Net Latent

BTU/H [kW]

6900 [2.0]

10000 [2.9]

13000 [3.8]

16700 [4.9]

SEER

17.00

17.00

17.00

16.00

EER

13.00

13.00

13.00

12.50

Indoor

CFM [L/s]

700 [330.4]

1050 [495.5]

1400 [660.7]

1550 [731.5]

AHRI#

8231639

8231642

8231644

8231646

Coil Only Ratings

Outdoor Unit

UA1724AJ2

UA1736AJ2

UA1748AJ2

UA1760AJ2

Indoor Coil

RCF2421MEAM+RXMD-C04

RCF3621MEAM+RXMD-C04

RCF6021SEAM+RXMD-C04

RCF6021SEAM+RXMD-C04

RCF6024MEAM+RXMD-C04

Total Capacity

BTU/H [kW]

24000 [7.0]

36000 [10.6]

36000 [10.6]

48000 [14.1]

55500 [16.3]

Net Sensible

BTU/H [kW]

17100 [5.0]

26000 [7.6]

26000 [7.6]

34600 [10.1]

38100 [11.2]

Net Latent

BTU/H [kW]

6900 [2.0]

10000 [2.9]

10000 [2.9]

13400 [3.9]

17400 [5.1]

SEER

15.10

15.10

15.50

15.50

14.50

EER

12.50

12.50

12.50

12.50

11.70

Indoor

CFM [L/s]

800 [377.6]

1200 [566.3]

1200 [566.3]

1550 [731.5]

1600 [755.1]

AHRI#

8234324

8231640

8231641

8231643

8231645

U802V: Ultra 2-Stage 80% ECM Furnace Ratings

Outdoor Unit

UA1724AJ2

UA1724AJ2

UA1724AJ2

UA1736AJ2

UA1736AJ2

UA1736AJ2

UA1736AJ2

UA1736AJ2

UA1748AJ2

UA1748AJ2

UA1748AJ2

UA1760AJ2

UA1760AJ2

UA1760AJ2

UA1760AJ2

UA1760AJ2

UA1760AJ2

Furnace Indoor Coil

Total Capacity

BTU/H [kW]

Net Sensible

BTU/H [kW]

Net Latent

BTU/H [kW]

U802VA050317MSA RCF2421MEAM 24000 [7.0] 17100 [5.0]

U802VA075317MSA RCF2421MEAM 24000 [7.0] 17100 [5.0]

U802VA075317ZSA RCF2421MEAM 24000 [7.0] 17100 [5.0]

U802VA075317MSA

6900 [2.0]

6900 [2.0]

6900 [2.0]

RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

U802VA075317ZSA

U802VA075421ZSA

RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

U802VA100521MSA

U802VA100521ZSA

RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

U802VA075421ZSA RCF6021SEAM

U802VA100521MSA RCF6021SEAM

U802VA100521ZSA RCF6021SEAM

47500 [13.9] 35400 [10.4] 12100 [3.5]

48000 [14.1] 35800 [10.5] 12200 [3.6]

47000 [13.8] 33900 [9.9] 13100 [3.8]

U802VA075421MSA RCF6024MEAM 55000 [16.1] 37300 [10.9] 17700 [5.2]

U802VA075421ZSA RCF6021SEAM 54000 [15.8] 37200 [10.9] 16800 [4.9]

RCF6021SEAM 55000 [16.1] 39200 [11.5] 15800 [4.6]

U802VA100521MSA

RCF6024MEAM 55500 [16.3] 38800 [11.4] 16700 [4.9]

RCF6021SEAM 54000 [15.8] 36900 [10.8] 17100 [5.0]

U802VA100521ZSA

RCF6024MEAM 55500 [16.3] 38700 [11.3] 16800 [4.9]

U802VA125524MSA RCF6024MEAM 55500 [16.3] 38800 [11.4] 16700 [4.9]

U802VA125524ZSA RCF6024MEAM 55500 [16.3] 38800 [11.4] 16700 [4.9]

SEER

17.00

17.00

17.00

17.00

17.00

16.50

17.00

17.00

17.00

17.00

17.00

17.00

17.00

17.00

17.00

17.00

16.00

15.50

16.00

16.00

15.50

16.00

16.00

16.00

[ ] Designates Metric Conversions

EER

13.00

13.00

13.00

13.00

13.00

13.00

13.00

13.00

13.00

13.00

13.00

13.00

13.00

12.50

13.00

13.00

12.50

11.70

12.00

12.50

12.00

12.00

12.50

12.00

AHRI#

8234319

8234320

8234321

8232069

8232078

8232070

8232079

8232071

8232080

8232072

8232081

8232073

8232082

8232087

8232088

8232089

8232096

8232092

8232093

8232097

8232094

8232098

8232099

8232100

Indoor

CFM [L/s]

725 [342.2]

675 [318.6]

725 [342.2]

1075 [507.3]

1075 [507.3]

1050 [495.5]

1050 [495.5]

1075 [507.3]

1075 [507.3]

1025 [483.7]

1025 [483.7]

1050 [495.5]

1050 [495.5]

1550 [731.5]

1525 [719.7]

1400 [660.7]

1425 [672.5]

1600 [755.1]

1725 [814.1]

1575 [743.3]

1550 [731.5]

1550 [731.5]

1575 [743.3]

1575 [743.3]

Rely on Ruud.™

19

Performance Data

UA17 Series

Performance Data @ AHRI Standard Conditions – Cooling (con’t.)

U96V: 96% AFUE 2-stage Variable Speed Multipoise Gas Furnace Uatings

Outdoor Unit

Furnace Indoor Coil

Total Capacity

BTU/H [kW]

UA1724AJ2

UA1724AJ2

Net Sensible

BTU/H [kW]

U96VA0602317MSA RCF2421MEAM 24000 [7.0] 17100 [5.0]

UA1736AJ2

Net Latent

BTU/H [kW]

6900 [2.0]

U96VA0702317MSA RCF2421MEAM 24000 [7.0] 17100 [5.0] 6900 [2.0]

RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

U96VA0602317MSA

RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

UA1736AJ2

UA1736AJ2

U96VA0702317MSA

U96VA0852521MSB

RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

UA1736AJ2

UA1748AJ2

UA1748AJ2

UA1760AJ2

UA1760AJ2

UA1760AJ2

U96VA1002521MSA

RCF3621MEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

RCF6021SEAM 36000 [10.6] 26000 [7.6] 10000 [2.9]

U96VA0852521MSB RCF6021SEAM 47500 [13.9] 35400 [10.4] 12100 [3.5]

U96VA1002521MSA RCF6021SEAM 47500 [13.9] 35400 [10.4] 12100 [3.5]

U96VA0852521MSB RCF6024MEAM 55000 [16.1] 38200 [11.2] 16800 [4.9]

RCF6021SEAM 53000 [15.5] 34800 [10.2] 18200 [5.3]

U96VA1002521MSA

RCF6024MEAM 55000 [16.1] 38200 [11.2] 16800 [4.9]

U96VA1152524MSA RCF6024MEAM 54500 [16.0] 36700 [10.8] 17800 [5.2]

SEER

17.00

17.00

16.50

17.00

16.50

17.00

16.50

17.00

17.00

17.00

17.00

17.00

15.50

15.50

15.50

16.00

EER

13.00

13.00

13.00

13.00

13.00

13.00

13.00

13.00

13.00

13.00

12.50

12.50

12.00

12.00

12.00

12.50

Indoor

CFM [L/s]

775 [365.8]

700 [330.4]

1050 [495.5]

1050 [495.5]

1050 [495.5]

1050 [495.5]

1075 [507.3]

1075 [507.3]

1050 [495.5]

1050 [495.5]

1550 [731.5]

1550 [731.5]

1550 [731.5]

1400 [660.7]

1550 [731.5]

1400 [660.7]

AHRI#

8234322

8234323

8232074

8232083

8232075

8232084

8232076

8232085

8232077

8232086

8232090

8232091

8232101

8232095

8232102

8232103

[ ] Designates Metric Conversions

20

Rely on Ruud.™

Guide Specifications

UA17 Series

GUIDE SPECIFICATIONS

General

System Description

Outdoor-mounted, air-cooled, split-system air conditioner composite base pan unit suitable for ground or rooftop installation.

Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser fan, suction and legend line service valve, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a coil unit.

Quality Assurance

— Unit will be rated in accordance with the latest edition of AHRI

Standard 210.

— Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory.

— Unit construction will comply with latest edition of ANSI/

ASHRAE and with NEC.

— Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval.

— Unit cabinet will be capable of withstanding ASTM B117 1000hr salt spray test.

— Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 550 psig.

— Unit constructed in ISO9001 approved facility.

Delivery, Storage, and Handling

— Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.

Warranty (for inclusion by specifying engineer)

— U.S. and

Canada only.

Products

Equipment

Factory assembled, single piece, air-cooled air conditioner unit.

Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge R-410A, and special features required prior to field start-up.

Unit Cabinet

— Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint.

— All units constructed with louver coil protection and corner post.

Louver can be removed by removing one fastener per louver panel.

AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER

UA17

1-1/2 TO 5 NOMINAL TONS

Fans

— Condenser fan will be direct-drive propeller type, discharging air upward.

— Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings.

Shafts will be corrosion resistant.

— Fan blades will be statically and dynamically balanced.

— Condenser fan openings will be equipped with coated steel wire safety guards.

Compressor

— Compressor will be hermetically sealed.

— Compressor will be mounted on rubber vibration isolators.

Condenser Coil

— Condenser coil will be air cooled.

— Coil will be constructed of aluminum fins mechanically bonded to copper tubes.

Refrigeration Components

— Refrigeration circuit components will include liquid-line shutoff valve with sweat connections, vapor-line shutoff valve with sweat connections, system charge of R-410A refrigerant, and compressor oil.

— Unit will be equipped with filter drier for R-410A refrigerant for field installation.

Operating Characteristics

— The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ °F/°C. The power consumption at full load will not exceed _____ kW.

— Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ °F/°C wet bulb and _____ °F/°C dry bulb, and air entering the unit at _____ °F/°C.

— The system will have a SEER of _____ Btuh/watt or greater at

DOE conditions.

Electrical Requirements

— Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v.

— Nominal unit electrical characteristics will be _____ v, three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v.

— Unit electrical power will be single point connection.

— Control circuit will be 24v.

Special Features

— Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.

Rely on Ruud.™

21

Limited Warranty

UA17 Series

GENERAL TERMS OF LIMITED WARRANTY*

Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.

*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the

Manufacturer for a copy of the product warranty certificate.

Conditional Unit Replacement

(Registration Required) ...............................Ten (10) Years

Parts ............................................................Ten (10) Years

22

Rely on Ruud.™

Notes

UA17 Series

Rely on Ruud.™

23

In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.

Ruud Heating, Cooling & Water Heating • P.O. Box 17010

Fort Smith, Arkansas 72917 • www.ruud.com

Ruud Canada • 125 Edgeware Road, Unit 1

Brampton, Ontario • L6Y 0P5

PRINTED IN U.S.A. 11/15 QG FORM NO. A22-223 REV. 3