American Water Heaters N40T62-403 Water Heater Use & care guide

Add to My manuals
32 Pages

advertisement

American Water Heaters N40T62-403 Water Heater Use & care guide | Manualzz

Home Appliances

o]

®

WARNING:

If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone.

Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

INSTALLER:

AFFIX THESE INSTRUCTIONS TO OR ADJACENT

TO THE WATER HEATER.

OWNER:

• RETAIN THESE INSTRUCTIONS AND WARRANTY

FOR FUTURE REFERENCE.

RETAIN THE ORIGINAL

RECEIPT AS PROOF OF PURCHASE.

Residential Gas

Water Heater with the Flame Lock®

Safety System

Installation

Instructions and

Use & Care Guide

NATURAL

&

L.P.

GAS MODELS

To obtain technical, warranty, or service assistance during or after the installation of this water heater, visit our website at:

http://www.whirlpoolwaterheatersupport.com

or call toll free

1-877-817-6750

When calling for assistance, please have the following information ready:

1.

2.

3.

4.

5.

Model number

7 digit product number

Serial number

Date of installation

Place of purchase

Table of Contents ......................................................

2

318051-002

October 2010

2

WATER HEATER SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word "DANGER" or

"WARNING." These words mean:

You can be killed or seriously injured if you don't

immediately follow

instructions.

You can be killed or seriously

injured if you don't follow

instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

Important Instructions

Do not use this appliance if any part has been under water. Immediately call a qualified person. Water heaters subjected to flood conditions or any time the gas controls, main burner or pilot have been submerged in water require replacement of the entire water heater.

Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydroqen qas is extremely flammable and can ignite when exposed to a spark or flame. To prevent the possibility of injury under these conditions, we recommend the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance which is connected to the hot water system. If hydrogen is present, there will probably be an unusual sound such as air escaping through the faucet as water begins to flow. Do not smoke or have any open flame near the faucet at the time it is open.

The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure to such substances.

WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm.

This appliance can cause low-level exposure to some of the substances included in the Act.

Table Of Contents PAGE

Water Heater Safety ..............................................................................

1-2

Installing Your Gas Water Heater ........................................................

3-16

Unpacking the Water Heater ...........................................................

Location Requirements ................................................................

3

4-5

Gas Supply ..................................................................................

6-7

Combustion Air Supply and Ventilation ......................................

7-11

Water System Piping ...............................................................

12-13

Temperature & Pressure Relief Valve ...........................................

14

Special Applications ......................................................................

Installation Checklist .....................................................................

15

16

Operating Your Water Heater ............................................................

Lighting Instructions......................................................................

17-21

17

Operating the Temperature Control System .................................

20

Operational Conditions .................................................................

21

Maintenance of Your Water Heater ...................................................

22-26

Troubleshooting Charts .....................................................................

Repair Parts Illustration .....................................................................

26-29

30-31

INSTALLING YOUR GAS WATER HEATER

Important Information About

This Water Heater

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. New technology used in meeting these standards makes this product more sensitive to installation errors or improper installation environments.

Please review the Installation Checklist found at the end of the installation instructions section and make any required installation upgrades or changes.

Consumer Information

This water heater is design-certified by CSA International as a Category I, non-direct vented water heater which takes its combustion air either from the installation area or from air ducted to the unit from the outside.

This water heater must be installed according to all local and state codes or, in the absence of local and state codes, the "National Fuel Gas Code", ANSI Z223.1(NFPA 54)current edition. This is available from the following:

CSA America, Inc.

8501 East Pleasant Valley Road

Cleveland, OH 44131

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02269

Check your phone listings for the local authorities having jurisdiction over your installation.

installed in accordance with Massachusetts Plumbing and

Fuel Gas Code 248 CMR Section 2.00 and 5.00.

A data plate identifying your water heater can be found next to the gas control valve/thermostat.

When referring to your water heater, always have the information listed on the data plate readily available.

Retain your original receipt as proof of purchase.

Unpacking the Water Heater

Excessive

Weight

Hazard

Use two or more people to move and install water heater.

Failure to do so can result in back or other injury.

IMPORTANT: Do not remove any permanent instructions, labels, or the data label from either the outside of the water heater or on the inside of water heater panels.

• Remove exterior packaging and place installation components aside.

• Inspect all parts for damage prior to installation and start-up.

• Completely read all instructions before attempting to assemble and install this product.

• After installation, dispose of/recycle all packaging materials.

Consumer Responsibilities

This manual has been prepared to acquaint you with the installation, operation, and maintenance of your gas water heater and provide important safety information in these areas.

Read all of the instructions thoroughly before attempting the installation or operation of this water heater.

Do not discard this manual. You or future users of this water heater will need it for future reference.

Service to the Flame Lock ® Safety System should only be performed by a qualified person.

Examples of a qualified person include: licensed plumbers, authorized gas company personnel, and authorized service personnel.

IMPORTANT: The manufacturer and seller of this water heater will not be liable for any damages, injuries, or deaths caused by failure to comply with the installation and operating instructions outlined in this manual.

If you lack the necessary skills required to properly install this water heater, or you have difficulty following the instructions, you should not proceed but have a qualified person perform the installation of this water heater.

Massachusetts code requires this water heater to be

Flammable

Vapors

FIRE AND EXPLOSION

HAZARD

Can result in serious injury or death

_Do

not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Storage of or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.

Read and follow water heater warnings and instructions.

Location Requirements

Carbon Monoxide Poisoning Hazard

Do not install in a mobile home.

Doing so can result in death or carbon monoxide poisoning.

The Flame Lock ® Safety System is designed to reduce the risk of flammable vapor-related fires. The patented system protects your family by trapping the burning vapors within the water heater combustion chamber through the special flame-trap. The burning vapors literally "burn themselves out" without escaping back into the room. In the event of a flammable vapor incident, the Flame Lock ®Safety System disables the water heater by shutting off the gas supply to the water heater's burner and pilot, preventing re-ignition of any remaining flammable vapors in the area. This will not prevent a possible fire/explosion if the igniter is depressed and flammable vapors have accumulated in the combustion chamber with the pilot light off. If you suspect a flammable vapor incident has occurred, do not use this appliance. Do not attempt to light this appliance, or depress the igniter button if you suspect flammable vapors have accumulated inside or outside the appliance. Immediately call a qualified person to inspect the appliance. Water heaters subjected to a flammable vapors incident will show a discoloration on the flame-trap and require replacement of the entire water

4 heater. Note: Not following these instructions and/or an inadequate air supply can cause the Flame Lock ® Safety

System to disable the water heater. Please make required installation and venting/air supply changes prior to resetting the system (see "Combustion Air Supply and Ventilation" section). IMPORTANT: This water heater has a resettable thermal switch installed as part of the Flame Lock ®Safety

System. Do not attempt to disable or modify this feature in any way.

Do not use or store flammable products such as gasoline, solvents, or adhesives in the same room or area near the water heater. If such flammables must be used, all gas burning appliances in the vicinity must be shut off and their pilot lights extinguished.

Open the doors and windows for ventilation while flammable substances are in use.

If flammable liquids or vapors have spilled or leaked in the area of the water heater, leave the area immediately and call the fire department from a neighbor's home. Do not attempt to clean the spill until all ignition sources have been extinguished.

Keep combustibles such as boxes, magazines, clothes, etc. away from the water heater area.

Site Location

Select a location near the center of the water piping system. The water heater must be installed indoors and in a vertical position on a level surface. Do not install in bathrooms, bedrooms, or any occupied room normally kept closed.

Locate the water heater as close to the chimney or gas vent as practical. Consider the vent system piping and combustion air supply requirements when selecting the water heater location. The venting system must be able to run from the water heater to termination with minimal length and elbows.

• Locate the water heater near the existing gas piping.

If installing a new gas line, locate the water heater to minimize the pipe length and elbows.

NOTE: This water heater must be installed according to all local and state codes or, in the absence of local and state codes, the "National Fuel Gas Code", ANSI Z223.1 (NFPA

54)-current edition.

in anareawhereleakageofthetankor connections willnotresultindamagetotheareaadjacenttothe waterheateror tolowerfloorsofthestructure.Due

Figure 1A

Air-moving

Devices

leakafteranextendedperiodoftime.

Alsoanyexternalplumbingleak,includingthosefrom maycauseearlyfailureofthetank is withmakingtherepaira qualifiedperson shouldbecontacted.Asuitablemetaldrainpanshould

beinstalledunderthewaterheaterasshownbelow, tohelpprotectthepropertyfromdamagewhichmay formationor leaksinthepiping

Exhaust

Fan i!

/

Reverse flow of gases

depthof 1-3/4"andbetwoincheswider drain.

airflow.

Locatethewaterheaternearanadequateindoordrain.

inchesabovea floordrainor externaltothebuilding.In

coldclimates,itis recommended atanadequate

Outsidedrainsaresubjecttofreezingtemperatures whichcanobstructthedrainline.Thepipingshouldbe

atleast3/4"IDandpitchedforproperdrainage.Under

waterheaterbeheldliableforanywaterdamagewhich is causedbyyourfailuretofollowtheseinstructions.

Figure 1

Drain Pan Installation

DISCHARGEPIPE

DO NOT CAP OR PLUG)

METAL

DRAIN

PANI

'_ _

_ AT

LEAST

DIAMETER

2" GREATER

OF THE WATER

©

THAN THE

©

HEATER.

!,,,MAXIMUM

AIR GAP

I

i_ ""_

/

PIPED

TO AN

ADEQUATE DRAIN

Clearances and Accessibility

NOTE: Minimum clearances from combustible surfaces are stated on the data plate adjacent to the gas control valve/ thermostat of the water heater.

The water heater is certified for installation on a combustible floor.

• IMPORTANT: If installing over carpeting, the carpeting must be protected by a metal or wood panel beneath the water heater. The protective panel must extend beyond the full width and depth of the water heater by at least three inches (76.2mm) in any direction; or if in an alcove or closet installation, the entire floor must be covered by the panel.

• Figure 2 may be used as a reference guide to locate the specific clearance locations. A minimum of 24 inches of front clearance should be provided for inspection and service.

Figure 2

Minimum Clearance

Locations

_Vent

Top

• The water heater should be located in an area not subject to freezing temperatures.

Water heaters located in unconditioned spaces (i.e., attics, basements, etc.) may require insulation of the water piping and drain piping to protect against freezing. The drain and controls must be easily accessible for operation and service. Maintain proper clearances as specified on the data plate.

• Do not locate the water heater near an air-moving device. The operation of air-moving devices such as exhaust fans, ventilation systems, clothes dryers, fireplaces, etc., can affect the proper operation of the water heater. Special attention must be given to conditions these devices may create. Flow reversal of flue gases may cause an increase of carbon monoxide inside of the dwelling.

• If the water heater is located in an area that is subjected to lint, dirt, and oil, it may be necessary to periodically clean the flame-trap (see "External

Inspection & Cleaning of the Flame-trap" section).

v/--Back c::=

__

Sides

____F io_t irniicm m

Top

T

ceilin

Side_ll

I

III

State of California

NOTE: The water heater must be braced, anchored, or strapped to avoid moving during an earthquake.

Contact local utilities for code requirements in your area, visit http://www.dsa.dgs.ca.gov, or call 1-916-445-8100 and request instructions.

Gas Supply

Figure 3

Gas Piping

Manual Gas

Shut-off Valve'---._

Check with local utility for

Joint

Union

Explosion Hazard

Use a new CSA approved gas supply line.

Install a shut-off valve.

Do not connect a natural gas water heater to an L.P. gas supply.

Do not connect an L.P. gas water heater to a natural gas supply.

Failure to follow these instructions can result in death, explosion, or carbon monoxide poisoning.

Gas Requirements

IMPORTANT: Read the data plate to be sure the water heater is made for the type of gas you will be using in your home. This information will be found on the data plate located near the gas control valve/thermostat.

If the information does not agree with the type of gas available, do not install or light. Call your dealer.

NOTE: An odorant is added by the gas supplier to the gas used by this water heater. This odorant may fade over an extended period of time. Do not depend upon this odorant as an indication of leaking gas.

Gas Piping

The gas piping must be installed according to all local and state codes or, in the absence of local and state codes, the "National

Fuel Gas Code", ANSI Z223.1 (NFPA 54)-current edition.

Tables 1 and 2 on page 7 provides a sizing reference for commonly used gas pipe materials. Consult the "National

Fuel Gas Code" for the recommended gas pipe size of other materials.

Refer to Figure 3

NOTE: When installing gas piping, apply approved pipe joint compound.

1.

Install a readily accessible manual shut-off valve in the gas supply line as recommended by the local utility.

Know the location of this valve and how to turn off the gas to this unit.

2.

Install a drip leg (if not already incorporated as part of the water heater) as shown. The drip leg must be no less than three inches long for the accumulation of dirt, foreign material, and water droplets.

3.

Install a ground joint union between the gas control valve/thermostat and the manual shut-off valve. This is to allow easy removal of the gas control valve/ thermostat.

4.

Turn the gas supply on and check for leaks. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak.

Correct any leak found.

minimum height 3"M _

Drip Leg i v

Gas Pressure

IMPORTANT: The gas supply pressure must not exceed the maximum supply pressure as stated on the water heater's data plate. The minimum supply pressure is for the purpose of input adjustment.

Gas Pressure Testing

IMPORTANT: This water heater and its gas connection must be leak tested before placing the appliance in operation.

If the code requires the gas lines to be tested at a pressure exceeding 14" W.C., the water heater and its manual shutoff valve must be disconnected from the gas supply piping system and the line capped.

• If the gas lines are to be tested at a pressure less than

14" W.C., the water heater must be isolated from the gas supply piping system by closing its manual shut-off valve.

U.L. recognized fuel gas and carbon monoxide (CO) detectors are recommended in all applications and should be installed using the manufacturer's instructions and local codes, rules, or regulations.

NOTE: Air may be present in the gas lines and could prevent the pilot from lighting on initial start-up. The gas lines should be purged of air by a qualified person after installation of the gas piping system. While purging the gas piping system of air, make sure that the fuel is not spilled in the area of the water heater installation, or any source of ignition. If the fuel is spilled while purging the piping system of air follow the "WHAT TO DO

IF YOU SMELL GAS" instructions on the cover of this manual.

LP Gas Only

Explosion Hazard

Have a qualified person make sure L.P. gas pressure does not exceed 13" water column.

Examples of a qualified person include: licensed plumbers, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Table 1

Natural Gas Pipe Capacity Table (Cu. Ft./Hr.)

Capacity of gas pipe of different diameters and lengths in cu. ft. per hr.

of 0.60 (natural gas).

with pressure drop of 0.3 in. and specific gravity

Nominallron

Size, in.

10

Pipe

20 30 40 50

Length ofPipe, Feet

60 70 80 90 100 125 150 175 200

1/2 132 92 73 63 56 50 46 43 40 38 34 31 28 26

3_ 278 190 152 130 115 105

1 520 350 285 245 215 195

96

180

90

170

84

160

79

150

72

130

64

120

59

110

55

100

1-1_ 1050 730 590 500 440 400 370 350 320 305 275 250 225 210

1-1/2 1600 1100 890 760 670 610 560 530 490 460 410 380 350 320

After the length of pipe has been determined, select the pipe size which will provide the minimum cubic feet per hour required for the gas input rating of the water heater. By formula:

Cu. Ft. Per Hr. Required=

Gas Input of Water Heater (BTU/HR)

Heating Value of Gas (BTU/FT 3)

The gas input of the water heater is marked on the water heater data plate. The heating value of the gas (BTU/FT _) may be determined by consulting the local natural gas utility.

Table 2

LP Gas Capacity Table

Maximum capacity of pipe in thousands of BTU per hour of undiluted liquefied petroleum gases (at 11 inches water column pressure).

Based on a pressure drop of 0.5 inch water column.

Nominal Iron Pipe

Size, in.

I 0 20 30 40

Length of Pipe, Feet

50 60 70

1/2

3/4

275

576

189

393

152 129

315 267

114

237

1 1071 732 590 504 448

1-1/4 2205 1496 1212 1039 913

103

217

409

834

96

196

378

771

80 90

89 83

185 173

346

724

322

677

I O0 125

78

162

69

146

307 275

630 567

150

63

132

252

511

Example: Input BTU requirement of the water heater 100,000 BTU/HR.

Total pipe length, 80 feet = 3/4" IPS required.

Additional tables are available in the latest edition of the "National Fuel Gas Code", ANSI Z223.1.

Combustion

Ventilation

Air Supply

and

Carbon Monoxide Hazard

Water heater must be vented to outdoors.

Vent must be installed by a qualified person

using the installation instructions.

Examples of a qualified

person

include: gas technicians, authorized gas company personnel, and authorized service persons.

Failure to follow these instructions can result in death or carbon monoxide poisoning.

IMPORTANT:

Air for combustion and ventilation must not come from a corrosive atmosphere. Any failure due to corrosive elements in the atmosphere is excluded from warranty coverage.

The following types of installation (not limited to the following) will require outdoor air for combustion due to chemical exposure and may reduce but not eliminate the presence of corrosive chemicals in the air:

• beauty shops

• photo processing labs

• buildings with indoor pools

• water heaters installed in laundry, hobby, or craft rooms

• water heaters installed near chemical storage areas

Combustion air must be free of acid-forming chemicals such as sulfur, fluorine, and chlorine. These elements are found in aerosol sprays, detergents, bleaches, cleaning solvents, air fresheners, paint, and varnish removers, refrigerants, and many other commercial and household products. When burned, vapors from these products form highly corrosive acid compounds. These products should not be stored or used near the water heater or air inlet.

Combustion and ventilation air requirements are determined by the location of the water heater. The water heater may be located in either an open (unconfined) area or in a confined area or small enclosure such as a closet or small room. Confined spaces are areas with less than 50 cubic feet for each 1,000 BTU/HR of the total input for all gas-using appliances.

Unconfined Space

Awater heater in an unconfined space uses indoor air for combustion and requires at least 50 cubic feet for each

1,000 BTU/HR of the total input for all gas appliances. The table below shows a few examples of the minimum square footage (area) required for various BTU/HR inputs.

Figure 4

Opening Locations-

Confined Spaces

I

12" maximum

Permanent openings to the outside or additional rooms within the building f

,F-1 f l m

4

Closet or other confined space

Table 2

BTU/HR

Input

30,000

45,000

I

Minimum Square

Feet with

8' Ceiling

188

281

Typical Room with 8' Ceiling

9 x 21

14 x 20

I=_

12" maximum J

60,000

75,000

90,000

105,000

120,000

375

469

563

657

750

15 x 25

15 x 31

20 x 28

20 x 33

25 x 30

135,000 844 28 x 30

IMPORTANT:

The area must be open and be able to provide the proper air requirements to the water heater. Areas that are being used for storage or contain large objects may not be suitable for water heater installation.

Water heaters installed in open spaces in buildings with unusually tight construction may still require outdoor air to function properly. In this situation, outside air openings should be sized the same as for a confined space.

Modern home construction usually requires supplying outside air into the water heater area.

Confined Space

For the correct and proper operation of this water heater, ample air must be supplied for the combustion, ventilation, and dilution of flue gases. Small enclosures and confined areas must have two permanent openings so that sufficient fresh air can be drawn from outside of the enclosure. One opening shall be within 12 inches of the top and one within

12 inches of the bottom of the enclosure as shown in

Figure 4.

The size of each opening (free area) is determined by the total BTU/HR input of all gas utilization equipment (i.e., water heaters, furnaces, clothes dryers, etc.) and the method by which the air is provided. The BTU/HR input can be found on the water heater data plate. Additional air can be provided by two methods:

1. All air from inside the building.

2. All air from outdoors.

All Air from Inside the Building

When additional air is to be provided to the confined area from additional room(s) within the building, the total volume of the room(s) must be of sufficient size to properly provide the necessary amount of fresh air to the water heater and other gas utilization equipment in the area. If you are unsure that the structure meets this requirement, contact your local gas utility company or other qualified agency for a safety inspection.

Each of the two openings shall have a minimum free area of 1 square inch per 1,000 BTU/HR of the total input rating of all gas utilization equipment in the confined area, but not less than 100 square inches (Figure 5).

Figure 5

All Air from Inside Building

Confined Space Installation

Confined

Space

Permanent

Openings inch/] 000

BTU/HR

(minimum

1 square

100 sq. In.)

All Air from Outdoors

Outdoor fresh air can be provided to a confined area either directly or by the use of vertical and horizontal ducts. The fresh air can be taken from the outdoors or from crawl or attic spaces that freely communicate with the outdoors.

Attic or crawl spaces cannot be closed and must be properly ventilated to the outside.

Ductwork must be of the same cross-sectional area as the free area of the opening to which they connect. The minimum dimension of rectangular air ducts cannot be less than three inches.

The size of each of the two openings is determined by the method in which the air is to be provided. Refer to Table

3 to calculate the minimum free area for each opening.

Figures 6, 7, and 8 are typical examples of each method.

Louvers and Grilles

In calculating free area for ventilation and combustion air supply openings, consideration must be given to the blocking effect of protection louvers, grilles, and screens.

These devices can reduce airflow, which in turn may require larger openings to achieve the required minimum free area. Screens must not be smaller than 1/4" mesh. If the free area through a particular design of louver or grille is known, it should be used in calculating the specified free area of the opening. If the design and free area are not known, it can be assumed that most wood louvers will allow

20 - 25% of free area while metal louvers and grilles will allow 60 - 75% of free area.

Louvers and grilles must be locked open or interconnected with the equipment so that they are opened automatically during equipment operation.

Keep louvers and grilles clean and free of debris or other obstructions.

Table 3

Minimum Free Area of Permanent Openings for Ventilation and

Combustion Air Supply - All Air from Outdoors Only.

Based on the total BTU/HR input rating for all utilizing equipment within the confined space.

Opening Source

Minimum Free Area

Per Opening (sq. in.)

Reference

Drawing

* Direct to outdoors 1sq. in,per4000 BTU/HR

Vertical ducts 1sq. in,per4000 BTU/HR

Figure 6

Figure 7

Horizontal ducts

Single Opening

1sq. in,per2000 BTU/HR

1sq.in, per3000 BTU/HR

Figure 8A

Figure 8B

Example: A water heater with an input rate of 50,000 BTU/HR using horizontal ducts would require each opening to have a minimum free area of 25 square inches.

Minimum free area = 50,000 BTU/HR x 1 sq. in. / 2000 BTU/HR =

25 Sq. Inches.

* These openings connect directly with the outdoors through a ventilated attic, a ventilated crawl space, or through an outside wall.

Consult the local codes of your area for specific ventilation and combustion air requirements.

Confined

Space

Alternate

Air Inlet

Confined

Space

Figure 7

All Air from Outdoors

Through Ventilated Attic

Confined

Space

Figure 8A

All Air from Outdoors

Using Horizontal Ducts

1 sq. inch per

2000 BTU/HR

Gable vent to outdoors

Install above insulation

Outlet air to attic

1 Sq. inch per

4000 BTU/HR

Inlet air from the crawl space

,-....

1 sq. inch per_

4000 BTU/HR

Open

Foundation"

Vent

Figure 6

All Air from Outdoors; Inlet Air from Ventilated

Crawl Space/Outlet Air to Ventilated Attic

Gable vent to outdoors

Install above insulation

Outlet air to attic

1 Sq.

inch per

4000 BTU/HR

.-.,,,

Inlet air duct

1 sq. inch per

4000 BTU/HR

12" maximum

Outlet

Inlet

t

Outdoor

Air Ducts

1 sq.

Inch per

2000 BTU/HR

Figure 9

Draft hood Installation

Alternative

Metal Screws (four provided)

_ _Draft hood

Confined

Space

II t

] sq. Inch "_

Per 3000 BTU/HR

Figure 8B

All Air from Outdoors

Using a Single Permanent Opening

Vent Pipe System

This water heater uses a non-direct, single-pipe vent system to remove exhaust gases created by the burning of fossil fuels. Air for combustion is taken from the immediate water heater location or is ducted in from the outside (see

"Combustion Air Supply and Ventilation" section).

This water heater must be properly vented for the removal of exhaust gases to the outside atmosphere.

Correct installation of the vent pipe system is mandatory for the proper and efficient operation of this water heater and is an important factor in the life of the unit.

The vent pipe must be installed according to all local and state codes or, in the absence of local and state codes, the

"National Fuel Gas Code", ANSI Z223.1 (NFPA 54)-current edition. The vent pipe installation must not be obstructed so as to prevent the removal of exhaust gases to the outside atmosphere.

IMPORTANT: The use of vent dampers is not recommended by the manufacturer of this water heater.

Although some vent dampers are certified by CSA

International, this certification applies to the vent damper device only and does not mean they are certified for use on this water heater.

U.L. recognized fuel gas and carbon monoxide (CO) detectors are recommended in all applications and should be installed using the manufacturer's instructions and local codes, rules, or regulations.

IMPORTANT:

If you lack the necessary skills required to properly install this venting system, you should not proceed, but get help from a qualified person.

Draft Hood Installation

Align the legs of the draft hood with the slots provided.

Insert the legs and secure the draft hood to the water heater's top with the four screws provided as shown in

Figure 9. Do not alter the draft hood in any way. If you are replacing an existing water heater, be sure to use the new draft hood supplied with the water heater.

Sl°tJ \ _ Jacket top P" LSl°t

Install the draft hood with the four screws provided.

Vent Pipe Size

It is important that you follow the guidelines in these instructions for sizing a vent pipe system. If a transition to a larger vent size is required, the vent transition connection must be made at the draft hood outlet.

Vent Connectors

1.

Type B, Double wall, U.L. Listed Vent Pipe.

2.

Single wall Vent Pipe.

Maintain the manufacturer's specified minimum clearance from combustible materials when using type B double wall vent pipe.

Vent connectors made of type B, double wall vent pipe material may pass through walls or partitions constructed of combustible material if the minimum listed clearance is maintained.

Maintain a six inch minimum clearance from all combustible materials when using single wall vent pipe.

IMPORTANT: Single wall vent pipe cannot be used for water heaters located in attics and may not pass through attic spaces, crawl spaces or any confined or inaccessible location. A single wall metal vent connector cannot pass through any interior wall.

When installing a vent connector, please note the following:

• Install the vent connector avoiding unnecessary bends, which create resistance to the flow of vent gases.

• Install without dips or sags with an upward slope of at least 1/4-inch per foot.

• Joints must be fastened by sheet metal screws or other approved means. It must be supported to maintain clearances and prevent separation of joints and damage.

• The length of the vent connector cannot exceed 75% of the vertical vent height.

• The vent connector must be accessible for cleaning, inspection, and replacement.

• Vent connectors cannot pass through any ceiling, floor, firewall, or fire partition.

• It is recommended (but not mandatory) that a minimum

12 inches of vertical vent pipe be installed on the draft hood prior to any elbow in the vent system to improve conditions for positive flow of venting gases.

IMPORTANT: Existing vent systems must be inspected for obstructions, corrosion, and proper installation.

10

Chimney Connection

IMPORTANT: Before connecting a vent to a chimney, make sure the chimney passageway is clear and free of obstructions. The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces. Also consult local and state codes for proper chimney sizing and application or, in the absence of local and state codes, the

"National Fuel Gas Code", ANSI Z223.1 (NFPA 54)-current edition.

• The connector must be installed above the extreme bottom of the chimney to prevent potentially blocking the flue gases.

• The connector must be firmly attached and sealed to prevent it from falling out.

• To aid in removing the connector, a thimble or slip joint may be used.

• The connector must not extend beyond the inner edge of the chimney as it may restrict the space between it and the opposite wall of the chimney (Figure 10).

Do not terminate the vent connector in a chimney that has not been certified for this purpose. Some local codes may prohibit the termination of vent connectors in a masonry chimney.

Vertical

Exhaust

Gas Vent

Vertical exhaust gas vents must be installed with U.L. listed type B vent pipe according to the vent manufacturer's instructions and the terms of its listing.

It must be connected to the water heater's draft hood by a listed vent connector or by directly originating at the draft hood opening.

Vertical gas vents must terminate with a listed cap or other roof assembly and be installed according to their manufacturer's instructions.

Gas vents must be supported to prevent damage, joint separation, and maintain clearances to combustible materials (Figures 11 and 12).

IMPORTANT: This gas vent must be terminated in a vertical position to facilitate the removal of the burnt gases.

An unused chimney flue or masonry enclosure may be used as a passageway for the installation of a gas vent

(Figure 12).

Common (combined) venting is allowable with vertical type

B vent systems and lined masonry chimneys as long as proper draft for the water heater is established under all conditions of operation.

IMPORTANT: Do not common vent this water heater with any power vented appliance.

Figures 10-12 are examples of vent pipe system installations and may or may not be typical for your specific application. Consult the "National Fuel Gas Code", NFPA

54, ANSI Z223.1-current edition and the guidelines set forth by prevailing local codes.

Figure 10

Chimney Termination

Vent System

3 ft. minimum_

Maintain clearance*

Strap

I

Listed Lined r_chimney

_

2 ft. minimum above any horizontally

Do not extend vent beyond edge of chimney

Vent

Connector

Figure 11

Vertical Gas

Vent System

With Type B

Double Wall

Vent Pipe,

Maintain Supp£,,_ Stra_ clearance* jX<,"_

_'_ "_1

,/--

Listed Vent Cap

J.

_ l

_ _ "----

. .

I I 2 ft. minimum above any

3 ft. minimum

I I_J,l_°bJ

I

ect within10 ft.

horizontally

\ _

I I < i H E_CCCZ

Type B Double

Wall Vent Pipe t

4CC_ Vent connector

I I slope up

I I

1/4.in.. perft.

L_

Figure 12

Venting Through a

'-'_"yr'_';mne'"

MAINTAIN MANUFACTURER'S

SPECIFIED

MINIMUM

CLEARANCE with

Type [3

Double Wall t

Vent

Pipe.

SUPPORT

*MAINTAIN

STRAP

CLEARANCE

VENT

CONNECTOR

SLOPE

I_IN.

PER FT.

MINIMUM mln_mum

,,, *Main ain,

speci lea clearance

LISTED VENT CAP

**MAINTAIN

SPECIFIED

CLEARANCE

CONNECTOR

UNUSED CHIMNEY

-_---FLUE

OR MASONRY

ENCLOSURE

* Maintain vent pipe clearance requirements to local, state and/or the "National Fuel Gas Code", ANSI Z223. I(NFPA

54)-current edition.

** NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances states that these chimneys are intended to be installed in accordance with the installation instructions provided with each chimney support assembly. Minimum air space clearance to combustible materials should be maintained as marked on the chimney sections.

11

12

Water System Piping

Piping Installation

Piping, fittings, and valves should be installed according to the installation drawing (Figure 13). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation.

The water supply pressure should not exceed 80 psi. If this occurs, a pressure reducing valve with a bypass should be installed in the cold water inlet line. This should be placed on the supply to the entire house in order to maintain equal hot and cold water pressures.

IMPORTANT: Heat cannot be applied to the water fittings on the heater as they may contain nonmetallic parts. If solder connections are used, solder the pipe to the adapter before attaching the adapter to the hot and cold water fittings.

IMPORTANT: Always use a good grade of joint compound and be certain that all fittings are drawn up tight.

1.

Install the water piping and fittings as shown in Figure

13. Connect the cold water supply (3/4" NPT) to the fitting marked "C". Connect the hot water supply (3/4"

NPT) to the fitting marked "H".

IMPORTANT: Some models may contain energy saving heat traps to prevent the circulation of hot water within the pipes. Do not remove the inserts within the heat traps.

2.

The installation of unions in both the hot and cold water supply lines is recommended for ease of removing the water heater for service or replacement.

3.

The manufacturer of this water heater recommends installing a mixing valve or an anti-scald device in the domestic hot water line as shown in Figure 14. These valves reduce the point-of-use temperature of the water by mixing cold and hot water and are readily available for use.

4.

If installing the water heater in a closed water system, install an expansion tank in the cold water line as specified under "Closed System/Thermal Expansion" section.

5.

Install a shut-off valve in the cold water inlet line. It should be located close to the water heater and be easily accessible.

Know the location of this valve and how to shut off the water to the heater.

6.

A temperature and pressure relief valve must be installed in the opening marked "Temperature and

Pressure (T & P) Relief Valve" on the water heater.

A discharge line must be added to the opening of the T&P Relief Valve. Follow the instructions under

"Temperature and Pressure Relief Valve" section.

,

After piping has been properly connected to the water heater, remove the aerator at the nearest hot water faucet. Open the hot water faucet and allow the tank to completely fill with water. To purge the lines of any excess air, keep the hot water faucet open for 3 minutes after a constant flow of water is obtained. Close the faucet and check all connections for leaks.

Figure 13

Water Piping Installation

Hot Water

Outlet_:E_ rm

r

In a closed system use a thermal expansion tank f--"S Cold Water

_" ....

[[_upply

, to Fixtures

_ _-Main water supply

Cold'Water

Inlet Valve

_-Pressure reducing valve with bypass

/,

Union

J

_ "-.,Temperature and

Pressure Relief Valve

Discharge Pipe

'"--Do Not Cap or Plug

Drain line 3/4"

1 "minimum '_ttftl

G

Metal

DrainPan/_

1 3/4" depth maximum j ID minimum

6" Maximum

"_ L---Air Gap u_ li=

V t

I Massachussetts:

Ilnstall a vacuum relief I hn cold water line per I

[section 19 MGL 142 J

Figure 14

Typical Mixing

Valve Installation

Follow the mixing valve manufacturer's instructions.

Tempered water to fixtures

!

Cold

Water

Inlet

Mixing valve

(Set to 120°F)

Pleasenotethefollowing:

• Thesystemshouldbeinstalledonlywithpipingthatis

Closed System/Thermal Expansion

installedusingironpipingor PVCwaterpiping.

• Useonlypumps,valves,orfittingsthatarecompatible withpotablewater.

• Useonlyfullflowballor gatevalves.Theuseofvalves

thatmaycauseexcessive notrecommended.

• Useonly95/5tin-antimony solder.

Anyleadbasedsoldermustnotbeused.

• Pipingthathasbeentreatedwithchromates, seal,orotherchemicalsmustnotbeused.

• Chemicals thepotablewater supplymustnotbeaddedtothepipingsystem.

Explosion Hazard

If the temperature and pressure relief valve is dripping or leaking, have a qualified person replace it.

Examples of a qualified person include: licensed plumbers, authorized gas company personnel, and authorized service personnel.

Do not plug valve.

Do not remove valve.

Failure to follow these instructions can result in death, or explosion.

As water is heated, it expands (thermal expansion).

In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion.

Thermal expansion can cause premature tank failure

(leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent temperature-pressure relief valve operation: water discharged from the valve due to excessive pressure build up. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion.

This condition is not covered under the limited warranty.

A properly-sized thermal expansion tank should be installed on all closed systems to control the effects of thermal expansion.

Contact a plumbing service agency or your retail supplier regarding the installation of a thermal expansion tank.

13

Temperature

Relief Valve and Pressure

Explosion Hazard

If the temperature and pressure relief valve is dripping or leaking, have a qualified person replace it.

Examples of a qualified person include: licensed plumbers, authorized gas company personnel, and authorized service personnel.

Do not plug valve.

Do not remove valve.

Failure to follow these instructions can result in death, or explosion.

Figure 15A

Temperature and Pressure

Relief Valve Installation

Optional location some models only

Relief Valve

Drain Line

3/4" ID minimum

t

-_ 6" Maximum

Air Gap t

Metal Drain Pan

For protection against excessive pressures and temperatures, a temperature and pressure relief valve must be installed in the opening marked "T & P RELIEF VALVE"

(see Figure 15A). This valve must be design certified by a nationally recognized testing laboratory that maintains periodic inspection of the production of listed equipment or materials as meeting the requirements for Relief Valves and

Automatic Shut-off Devices for Hot Water Supply Systems,

ANSI Z21.22. The function of the temperature and pressure relief valve is to discharge water in large quantities in the event of excessive temperature or pressure developing in the water heater. The valve's relief pressure must not exceed the working pressure of the water heater as stated on the data plate.

14

IMPORTANT: Only a new temperature and pressure relief valve should be used with your water heater. Do not use an old or existing valve as it may be damaged or not adequate for the working pressure of the new water heater. Do not place any valve between the relief valve and the tank.

The Temperature & Pressure Relief Valve:

• Must not be in contact with any electrical part.

• Must be connected to an adequate discharge line.

• Must not be rated higher than the working pressure shown on the data plate of the water heater.

The Discharge Line:

• Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line.

• Must not be capped, blocked, plugged or contain any valve between the relief valve and the end of the discharge line.

• Must terminate a maximum of six inches above a floor drain or external to the building. In cold climates, it is recommended that the discharge pipe be terminated at an adequate drain inside the building.

• Must be capable of withstanding 250°F (121°C) without distortion.

• Must be installed to allow complete drainage of both the valve and discharge line.

T&P Relief Valve and Pipe Insulation

(Some

Models)

1.

Locate the temperature and pressure relief valve on the water heater (also known as a T&P relief valve).

See Figure 15B.

2.

Locate the slit running the length of the T&P relief valve insulation.

3.

Spread the slit open and fit the insulation over the T&P relief valve.

See Figure 15B. Apply gentle pressure to the insulation to ensure that it is fully seated on the

T&P Relief Valve. Once seated, secure the insulation with duct tape.

IMPORTANT: The insulation or tape should not block or cover the T&P relief valve drain opening. Also, the insulation or tape should not block or hinder access to the manual relief lever (Figure 15B).

4.

Locate the hot water (outlet) & cold water (inlet) pipes to the water heater.

5.

Locate the slit running the length of a section of pipe insulation.

6.

Spread the slit open and slip the insulation over the cold water (inlet) pipe. Apply gentle pressure along the length of the insulation to ensure that it is fully seated around the pipe. Also, ensure that the base of the insulation is flush with the water heater.

Once seated, secure the insulation with duct tape.

7.

Repeat steps 5 and 6 for the hot water (outlet) pipe.

8.

Add additional sections of pipe insulation as needed.

Figure 15B

T&P Relief Valve Insulation

T&P Relief Valve

Drain Line ief Lever

T&P Relief Valve Insulation

Special Applications

Combination Space Heating/Potable

Water System

Some water heater models are equipped with inlet/outlet tappings for use with space heating applications. If this water heater is to be used to supply both space heating and domestic potable (drinking) water, the instructions listed below must be followed.

Be sure to follow the manual(s) shipped with the air handler system.

• This water heater is not to be used as a replacement for an existing boiler installation.

• Do not use with piping that has been treated with chromates, boiler seal or other chemicals and do not add any chemicals to the water heater piping.

• If the space heating system requires water temperatures in excess of 120°F, a mixing valve or an antiscald device should be installed per its manufacturer's instructions in the domestic (potable) hot water supply to limit the risk of scald injury.

• Pumps, valves, piping and fittings must be compatible with potable water.

A properly installed flow control valve is required to prevent thermosiphoning.

Thermosiphoning is the result of a continuous flow of water through the air handler circuit during the off cycle. Weeping (blow off) of the temperature and pressure relief valve (T & P) or higher than normal water temperatures are the first signs of thermosiphoning.

The domestic hot water line from the water heater should be vertical past any mixing valve or supply line to the air handler to remove air bubbles from the system. Otherwise, these bubbles will be trapped in the air handler heat exchanger coil, reducing the efficiency.

• Do not connect the water heater to any system or components previously used with non-potable water heating appliances when used to supply potable water.

Some jurisdictions may require a backflow preventer in the incoming cold water line. This may cause the temperature and pressure relief valve on the water heater to discharge or weep due to expansion of the heated water.

A diaphragm-type expansion tank suitable for potable water will normally eliminate this weeping condition. Please read and follow the manufacturer's instructions for the installation of such tanks.

Also see "Water System Piping" section for additional instructions on the proper installation and operation of this water heater.

Figure 16

Typical Mixing Valve Installation

Combination Space Heating/Potable

Water Heating System Must be vertical to air bubbles

Domestic

Mixin,_

Hot Water/

Ou

/

_--remove

Cold

ValveU _'_G _Wn_

Hot II _ I III

Water_ _I_ LL_

Out

.

_

_ r

Unions

Ill

_"

II,

To

Air

:::::::_ / Handler

Out

Flow Control

Valve

Coil

_Discharge Pipe

Do Not Cap or Plug

Shut-off

Valve

Air

Handler

, r_ 7-_--_irt_ax_m um

Metal Drain Pan Floor

Massachusetts code does not allow this type of installation.

Solar Installation

If this water heater is used as a solar storage heater or as a backup for the solar system, the water supply temperatures to the water heater tank may be in excess of

120°F. A mixing valve or other temperature limiting valve must be installed in the water supply line to limit the supply temperature to 120°F. The unit must be set to Standard

Mode (See Operating the Temperature Control System section).

NOTE: Solar water heating systems can often supply water with temperatures exceeding 180°F and may result in water heater malfunction.

15

Important Information About This Water Heater

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation errors. Please review the following checklist and make any required installation upgrades or changes.

Questions?

Call 1-877-817-6750.

Installation Checklist

Water

Heater Location

Water heater location is important and can affect system performance.

Please check the following:

[] Installation area free of corrosive elements and flammable materials.

[] Centrally located with the water piping system.

Located as close to the gas piping and vent pipe system as possible.

[] Located indoors and in a vertical position. Protected from freezing temperatures.

[] Proper clearances from combustible surfaces maintained and not installed directly on a carpeted floor.

[] Provisions made to protect the area from water damage. Metal drain pan installed and piped to an adequate drain.

[] Sufficient room to service the water heater. See

"Clearances and Accessibility" section of this manual.

[] Water heater not located near an air moving device.

[] Is the installed environment dirty (excessive amounts of lint, dirt, dust, etc.)?

If so, the flame arrestor located on the bottom of the water heater will need to be cleaned periodically.

Refer to the

"Maintenance of your Water Heater" section of this manual for information on cleaning the flame-trap.

Combustion Air Supply and Ventilation

Check for sufficient combustion air supply.

Insufficient air for the combustion of gas will result in the flame becoming

"lazy", thereby allowing heat to build up in the combustion chamber.

This excessive heat will cause a thermal switch on the door assembly to trip. Is the water heater installed in a closet or other small, enclosed space? If so:

[] Are there openings for make-up air to enter and exit the room/area?

[] Are the openings of sufficient size?

Remember, if there are other gas-fired or air-consuming appliances in the same room, you need more make-up air. Refer to the "Location Requirements" section of this water heater manual for specific requirements.

Conditioning & Refrigeration (HVAC-R) authorized service provider.

[] Fresh air supply free of corrosive elements and flammable vapors.

[] Fresh air openings sized correctly with consideration given to the blocking effect of louvers and grilles.

[] Ductwork is the same cross-sectional area as the openings.

Vent Pipe System

Check for proper drafting at the water heater draft hood.

Refer to the "Checking the Draft" section of this manual for the test procedure. If the procedure shows insufficient draft is present, please check the following.

[] Draft hood properly installed.

[] Vent connectors securely fastened with screws and supported properly to maintain six inch clearance.

[] Vent connector made of approved material and sized correctly.

[] Vent pipe system installed according to all local and state codes or, in the absence of local and state codes, the "National Fuel Gas Code", ANSI

Z223.1 (NFPA 54)-current edition.

[] Flue baffle properly positioned in the flue tube.

[] Check the vent system for restrictions/obstructions and check the vent termination height.

Refer to the

"Air Supply and Ventilation" section of this water heater manual for specific requirements.

[] Recheck for sufficient combustion air supply.

Water

System Piping

[] Temperature and pressure relief valve properly installed with a discharge line run to an open drain and protected from freezing.

[] All piping properly installed and free of leaks.

[] Heater completely filled with water.

[] Closed system pressure build-up devices installed.

[] Mixing valve (when applicable) installed per manufacturer's instructions (see "Water Temperature

Regulation" section).

Fresh air not taken from areas that contain negative pressure producing devices such as exhaust fans, fireplaces, etc.

[] Is there a furnace/air handler in the same room space as the water heater?

If so, has a return air duct system been attached that exits the room?

If so, check for leaks on the air duct system. If no air duct system is present, correct immediately by contacting a local Heating, Ventilation, Air-

Gas Supply and Piping

[] Gas type is the same as that listed on the water heater data plate.

[] Gas line equipped with shut-off valve, union, and drip leg.

[] Adequate pipe size and approved pipe material.

[] An approved noncorrosive leak detection solution used to check all connections and fittings for possible gas leaks. Correct any leak found.

TEFLON ® is a registered trademark of E.I. Du Pont De Nemours and Company.

16

OPERATING YOUR WATER HEATER

Lighting Instructions

Read and understand these directions thoroughly before attempting to light or re-light the pilot. Make sure the viewport is not missing or damaged. (See Figure 23)

Make sure the tank is completely filled with water before lighting the pilot. Check the data plate near the gas control valve/thermostat for the correct gas. Do not use this water heater with any gas other than the one listed on the data plate. If you have any questions or doubts, consult your gas supplier or gas utility company.

f

Explosion Hazard

Replace viewport if glass is missing or damaged.

Failure to do so can result in death,

explosion or fire.

FORYOURSAFETYREADBEFORELIGHTING

I WARNING:

If you do not follow these instructions exactly, a fire or explosion I may result causing property damage, personal injury or loss of life.

I

A.

B.

This appliance has a pilot which is lighted by a piezoelectric igniter. When lighting the pilot, follow these instructions exactly.

BEFORELIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.

Use only your hand to push in or turn the gas control temperature knob. Never use tools. If the knob wilI not push in or move by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.

Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance. Water heaters subjected to flood conditions or anytime the gas controls, main burner or pilot have been submerged in water require replacement of the entire water heater.

E.

DO NOTUSE THISAPPLIANCE IF THERE HAS BEEN AN

IGNITIONOFVAPORS.Immediatelycall a qualified service technician to inspect the appliance. Water heaters subjected to a flammable vapors ignition will show a discoloration on the air intake grid (bottom of combustion chamber) and requirereplacementof the entirewater heater.

1.

2.

Turn the gas control/temperature knob counterclockwise_f'_ to the "OFF" setting.

Gas control/

LIGHTING INSTRUCTIONS

STOP!It is imperativethat you read all safety warnings before lighting the pilot.

Press the gas control/temperature knob all the way in and hold it in. The knob should travel in about 1/4 inch

(6.35 mm) if it is set to "PILOT" correctly.

While holdina the aas control/temperature knob in click the ianiter button continuously (about once a second) for up to 90 seconds or until Status Liqht beqins to blink.

knob

Button

Status lig

Wait ten (10) minutes to clear out any gas.

If you then smell gas, STOP! Follow "B" in the safety information above on this label. If you do not smell gas, go to the next step.

Turn the gas control/temperature knob clockwise to "PILOT".

When the status light starts blinking, release the gas control/temperature knob. Set the gas control/temperature knob to the desired setting.

If the status light does not start blinking within 90 seconds, repeat steps 2 through 5 up to THREE (3) times, waiting 10 minutes between lighting attempts.

The circuitry in this advanced aas valve reauires that you wait 10 minutes between liqhtinq attempts.

If the status light turns solid red, release the gas control/temperature knoband repeat steps 2 through 5

(waiting 10minutes before attempting to relight the pilot).

If the status light does not start blinking after three lighting attempts,turn the gas control/temperatureknob to "OFF" and call a qualified service technician or your gas supplier.

Thermopile

,ow_

TO TURNOFFGASTOAPPLIANCE

1.

Turn the gas control/temperature knob counterclockwise _ to the "OFF" setting. The status lightwilI stop blinking and stay on for a short time after the water heater is turned off.

Pflot_

17

L.P.G. (Bottled Propane) Models

Liquefied petroleum gas is over 50% heavier than air and in the occurrence of a leak in the system, the gas will settle at floor level. Basements, crawl spaces, skirted areas under mobile homes (even when ventilated), closets and areas below ground level will serve as pockets for the accumulation of gas. Before lighting an L.R gas water heater, smell all around the appliance at floor level. If you smell gas, follow the instructions as given in the warning on the front page.

When your L.R tank runs out of fuel, turn off the gas at all gas appliances including pilot lights. After the tank is refilled, all appliances must be re-lit according to their manufacturer's instructions.

Checking the Draft

Burn Hazard

Do not touch vent.

Doing so can result in burns.

After successfully lighting the water heater, allow the unit to operate for 15 minutes and check the drafthood relief opening for proper draft. Make sure all other appliances in the area are operating and all doors are closed when performing the draft test. Pass

Figure 17 Drafthood

a match flame around the relief

Relief

M Opening

opening of the drafthood. A steady flame drawn into the opening indicates proper draft. If the flame flutters or is blown out, combustion products are escaping from the relief opening. If this occurs, do not operate the water heater until proper adjustments or repairs are made to the vent pipe system and/or air supply requirements.

Burner Flames

Inspect the burner flames through the viewport and compare them to the drawings in Figure 18. A properly operating burner should produce a soft blue flame.

Figure 18

Flame Characteristics

Blue tips with yellow inner cones

Tips may have

a yellow tint are satisfactory.

The tips of the elnlOWainner flame may have a slight yellow tint.

The flame should atisfactory

Correct flame soft blue not be all yellow or have a sharp blue-orange color.

Contaminated air may cause an orange colored flame. Contact a qualified person if the flame is not satisfactory.

Water Temperature Stacking

Stacking occurs when a series of short draws of hot water

(3 gallons or less) are taken from the water heater tank.

This causes increased cycling of the burner and can result in increased water temperatures at the hot water outlet.

This water heater's temperature control has been designed to accurately regulate the water temperature.

However, under certain operating conditions, the water temperature may temporarily exceed the dial setting. Consequently, in addition to setting the temperature no higher than 120°F, we recommend the installation of a mixing valve or an anti-scald device in the hot water supply line or at the point of use to further reduce the risk of scald injury. These devices can be obtained from a plumbing service agency or your retail supplier.

Emergency Shut Down

IMPORTANT: Should overheating occur or the gas supply fails to shut off, turn off the water heater's manual gas control valve and call a qualified person.

18

Water Temperature Regulation

Water temperature over 125°F can cause severe burns instantly or death from scalds.

Children, disabled and elderly are at highest risk of being scalded.

Feel water before bathing or showering.

Temperature limiting valves are available.

The thermostat is adjusted to the pilot position when it is shipped from the factory. Water temperature can be regulated by moving the temperature dial to the preferred setting. The preferred starting point is 120°F at the "HOT" setting. Align the knob with the desired water temperature as shown in Figure 19A. There is a hot water scald potential if the thermostat is set too high.

NOTE: Temperatures shown on the gas control valve/ thermostat are approximates.

The actual temperature of the heated water may vary.

IMPORTANT:

Adjusting the thermostat past the 120°F bar on the temperature dial will increase the risk of scald injury.

Hot water can produce first degree burns within:

Table 4:

Water

Temperature °F

110

116

116

122

131

140

149

154

Time for 1st Time for

Permanent Burns

Degree Burn 2nd & 3rd Degree

(Less Severe Bums) (Most Severe Bums)

(normalshower temp.)

(pain threshold)

35 minutes

1 minute

5 seconds

2 seconds

1 second instantaneous

45 minutes

5 minutes

25 seconds

5 seconds

2 seconds

1 seconds

(U.S. Govemment Memorandum, C.RS.C., Peter L. Armstrong, Sept. 15,1978)

Figure 19A

Gas Control Valve/Thermostat

Settings

Control/Temperature niter

Knob

120°F

Status Mirk

NOTE: During low demand periods when hot water is not being used, a lower thermostat setting will reduce energy losses and may satisfy your normal hot water needs.

If hot water use is expected to be more than normal, a higher thermostat setting may be required to meet the increased demand. When leaving your home for extended periods (vacations, etc.) turn the temperature dial to the vacation (VAC) setting. This will maintain the water at low temperatures with minimum energy losses and prevent the tank from freezing during cold weather.

19

Operating the Temperature Control System

Figure 19B: Status Codes

Status Light Code

Normal Flashes:

List of status codes are shown at top of gas control valve/thermostat,

• 0 Flashes Indicates Control Off/Pilot Out.

• 1 Flash Indicates Normal Operation.

LOW'

C

V_Q

PILOT

• Continuous Light indicates the gas control valve/thermostat is shutting down.

Diagnostic Flashes: If the water heater is not working look for the following diagnostic flashes after lighting the pilot.

2 Flashes

Indicates Thermopile Voltage Low

4 Flashes Indicates Overheat Failure

5 Flashes

7 Flashes

8 Flashes

Indicates Sensor Failure

Indicates Electronic Control Failure

See "Status Light Code Troubleshooting Chart."

Water Temperature Adjustment

The water temperature can be adjusted from 55°F to 155°F.

Turn the Gas Control/Temperature Knob to the desired setting/temperature.

NOTE: Some models are certified for 180°F outlet temperatures.

See the Data Plate on the front of the water heater for the maximum outlet temperature.

Operating Modes and Settings

Standard Mode - The controller adjusts the water heater to maintain the temperature set by the user.

• Vacation Setting - The controller adjusts the water temperature to approximately 55°F. This setting is recommended when the water heater is not in use for a long period of time. This effectively turns the water heater down to a setting that prevents the water from freezing.

20

Operational Conditions

Condensation

Moisture from the products of combustion condenses on the tank surface and the outside jacket of the water heater and forms drops of water which may fall onto the burner or other hot surfaces. This will produce a "sizzling" or "frying" noise.

NOTE: This condensation is normal and should not be confused with a leaking tank. Condensation may increase or decrease at different times of the year.

High efficient energy saver water heaters will produce larger amounts of condensation on initial start-up or when a large amount of hot water is being used. NOTE: Do not confuse this with a "tank leak". Once the water reaches a temperature of 120°F and the tank warms up (usually 1-2 hours), the condensation will stop.

IMPORTANT: It is always recommended that a suitable metal drain pan be installed under the water heater to protect the area from water damage resulting from normal condensation production, a leaking tank or piping connections. Refer to "Location Requirements" on page

4. Under no circumstances is the manufacturer to be held responsible for any water damage in connection with this water heater.

Water Heater Sounds

During the normal operation of the water heater, sounds or noises may be heard. These noises are common and may result from the following:

1.

Normal expansion and contraction of metal parts during periods of heat-up and cool-down.

2.

Condensation causes sizzling and popping within the burner area and should be considered normal.

3.

Sediment buildup in the tank bottom will create varying amounts of noise and may cause premature tank failure.

Drain and flush the tank as directed under "Draining and

Flushing".

Smoke/Odor

The water heater may give off a small amount of smoke and odor during the initial start-up of the unit. This is due to the burning off of oil from metal parts of a new unit and will disappear after a few minutes of operation.

Safety Shut-off

This water heater is designed to automatically shut-off in the event of the following:

1.

The pilot flame is extinguished for any reason.

2.

The water temperature exceeds 189°F (87°C)for 155°F models or 199°F (93°C) for 180°F models. See the data plate for your model.

3.

Excessive combustion chamber temperatures.

4.

The ignition of flammable vapors.

A thermopile is used to determine if a pilot flame is present, and will shut off the gas supply to the main burner and the pilot if the flame is absent. This unit is also equipped with a thermal switch, designed to shut off the gas supply in the event the heater has been exposed to flammable vapors (spilled gasoline or paint fumes for example), poor combustion caused by a blocked vent or insufficient combustion air. If the switch opens, check the flame-trap for signs of high temperature

(blue or black discoloration), and inspect your installation for any problems with venting or combustion air (See Pilot Light

Troubleshooting Flowchart on page 29). Reset the switch by depressing the small button in the center of the switch.

IMPORTANT: Correct any issues prior to resetting the switch.

Contact the Product Service and Support Department for service information at: 1-877-817-6750.

A temperature limit switch or ECO (Energy Cut Off) sensor located in the gas control valve\thermostat, is used to shut off the water heater if the water temperature exceeds 189°F (87°C) for

155°F models or 199°F (93°C) for 180°F models. See the data plate for your model.

The Diagnostic Status Light will flash a code indicating an "Overheat Failure" (4 Flashes). See "Operating the

Temperature Control System." If the ECO has functioned the gas control valve/thermostat should be replaced by a qualified person. Contact your local dealer for service information.

Anode Rod/Water Odor

Each water heater contains at least one anode rod, which will slowly deplete (due to electrolysis) prolonging the life of the water heater by protecting the glass-lined tank from corrosion. Adverse water quality, hotter water temperatures, high hot water usage, hydronic heating devices, and water softening methods can increase the rate of anode rod depletion. Once the anode rod is depleted, the tank will start to corrode, eventually developing a leak.

Certain water conditions will cause a reaction between the anode rod and the water. The most common complaint associated with the anode rod is a "rotten egg smell" produced from the presence of hydrogen sulfide gas dissolved in the water.

IMPORTANT:

Do not remove this rod permanently as it will void any warranties. A special anode rod may be available if water odor or discoloration occurs.

NOTE: This rod may reduce but not eliminate water odor problems. The water supply system may require special filtration equipment from a water conditioning company to successfully eliminate all water odor problems.

Artificially softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium ions. The use of a water softener may decrease the life of the water heater tank.

The anode rod should be removed from the water heater tank every 3 years for inspection.

NOTE: artificially softened water requires the anode rod to be inspected annually.

The following are typical (but not all) signs of a depleted anode rod:

The majority of the rods diameter is less than 3/8".

• Significant sections of the support wire (approx. 1/3 or more of the anode rod's length) are visible.

If the anode rod show signs of either or both it should be replaced. NOTE:

Whether re-installing or replacing the anode rod, check for any leaks and immediately correct if found.

In replacing the anode:

AnodeRodDepletion

Exposed

Wire

_-

1.

Turn off gas supply to the water heater. Pitted

2.

Shut off the water supply and open a nearby hot water faucet to depressurize the water tank.

Anode

Rod-_.

3.

Drain approximately 5 gallons of water from tank. (Refer to "Draining and Flushing" for proper procedures).

Close drain valve.

4.

Remove old anode rod.

5.

Use Teflon® tape or approved pipe sealant on threads and install new anode rod.

Exposed

Support_ wire

'

6.

Turn on water supply and open a nearby hot water faucet to purge air from water system.

7.

Check for any leaks and immediately correct any if found.

8.

Restart the water heater as directed in this manual. See the Repair Parts Illustration for anode rod location.

TEFLON ® is a registered trademark of E.I. Du Pont De Nemours and Company.

21

MAINTENANCE OF YOUR WATER HEATER

Draining and Flushing

It is recommended that the tank be drained and flushed every 6 months to remove sediment which may build up during operation. The water heater should be drained if being shut down during freezing temperatures.

To drain the tank, perform the following steps:

1.

Turn off the gas to the water heater at the manual gas shut-off valve.

2.

Open a nearby hot water faucet until the water is no longer hot.

3.

Close the cold water inlet valve.

4.

Connect a hose to the drain valve and terminate it to an adequate drain or external to the building.

5.

Open the water heater drain valve and allow all of the water to drain from the tank. Flush the tank with water as needed to remove sediment.

6.

Close the drain valve, refill the tank, and restart the heater as directed in this manual.

If the water heater is going to be shut down for an extended period, the drain valve should be left open.

IMPORTANT: Condensation may occur when refilling the tank and should not be confused with a tank leak.

Temperature and Pressure

Relief Valve

Explosion Hazard

If the temperature and pressure relief valve is dripping or leaking, have a qualified person replace it.

Examples of a qualified person include: licensed plumbers, authorized gas company personnel, and authorized service personnel.

Do not plug valve.

Do not remove valve.

Routine Preventative

Maintenance

At least annually, a visual inspection should be made of the venting and air supply system, piping systems, main burner, pilot burner, and Flame-trap. Check the water heater for the following:

• Obstructions, damage, or deterioration in the venting system. Make sure the ventilation and combustion air supplies are not obstructed.

• Build up of soot and carbon on the main burner and pilot burner. Check for a soft blue flame.

• Leaking or damaged water and gas piping.

• Presence of flammable or corrosive materials in the installation area.

• Presence of combustible materials near the water heater.

• After servicing this water heater, check to make sure it is working properly. (See Operating Your Water Heater section of this manual.)

IMPORTANT: If you lack the necessary skills required to properly perform this visual inspection, you should not proceed, but get help from a qualified person.

Failure to follow these instructions can result in death, or explosion.

Manually operate the temperature and pressure relief valve at least once a year to make sure it is working properly. To prevent water damage, the valve must be properly connected to a discharge line which terminates

Figure 21

I R_m_e and Pressure

Discharge line to drain at an adequate drain. Standing clear of the outlet (discharged water may be hot), slowly lift and release the lever handle on the temperature and pressure relief valve to allow the valve to operate freely and return to its closed position. If the valve fails to completely reset and continues to release water, immediately shut off the manual gas control valve and the cold water inlet valve and call a qualified person.

22

Replacement Parts

IMPORTANT: The following maintenance procedures are for the Flame Lock ® Safety System components and should be performed by a qualified person.

Replacement parts may be ordered through your plumber or the local distributor. Parts will be shipped at prevailing prices and billed accordingly. When ordering replacement parts, always have the following information ready:

1.

model, serial, and product number

2.

type of gas

3.

item number

4.

parts description

See pages 30-31 for a list of available repair parts.

Removing the Manifold Assembly

1.

Turn off the gas to the water heater at the manual shut-off valve (Figure 3).

2.

Turn the gas control/temperature knob to the "OFF" position (Figure 19A).

,

Figure 22

Gas Control Valve/

Thermostat

4.

Remove the outer door.

Remove the two screws

(1/4" nut driver) securing the manifold door assembly to the combustion chamber

(Figure 23).

o

,

Disconnect the pilot tube

(7/16" wrench), the igniter wire from the igniter lead wire, and manifold tube

Ignite

Butto

Ignit_

_ead

_!

S _'_'_'_'_'_'_'_'_'_ White

_ _ Wire

_

I1

_ q_ !_/i (R.ig,ht

_ _ _\_ bl.ae)

(3/4" wrench) at the gas control valve/thermostat.

Also use needle nose pliers to disconnect the red (+) wire

UJPilot i

.,!i

Tube )

!g.niter

7_

/

Manifold

Tube and white (-) thermopile wires from the gas control valve/thermostat.

See

\

Red

Wire

(Left

Side 1

Figures 22 & 23. NOTE: L.P. Gas systems use reverse (left-hand) threads on the manifold tube.

6.

Grasp the manifold tube and push down slightly to free the manifold, pilot tube, and thermopile.

7.

Carefully remove the manifold assembly from the burner compartment.

NOTE: Be sure not to damage internal parts.

Figure 23

Burner Assembly

Removal

Gas Control Valve/Thermostat Thermopile and

Switch Wire

Connections

Piezo Igniter

Pilot Tube_ Vlanifold Tube

Switch

Removing

the Burner from the

Manifold Assembly

Natural Gas Burner (Low Nox) & L.P. Burner

1.

Take off the burner by removing the two (2) screws located underneath the burner.

2.

Check the burner to see if it is dirty or clogged. The burner may be cleaned with soap and hot water (Figure 24A).

Figure 24A

Natural gas (Low NOx) and L.P.

Burner Assembly

_---_

Manifold Component

Block_

\

Manifold

Gasket

P,ot \

jBracket

Manifold Door Assembly

Switch

Therm°pile C°n nect°r"---_ 1 ]

Pilot/Thermopile

Assembly

III qlPlt

A /

_Pilot Tube

_/anifold Tube screws

_ .

Hiot/Thermopi e Assembly

Manifold Door

Assembly

L.R Gas Cast Iron Burner

1.

Separate the pilot bracket from the L.P. burner by removing screw.

2.

Loosen set screw located on top of the L.P. burner near the manifold door. Gently, pull the burner away from the manifold door assembly.

3.

Check the burner to see if it is dirty or clogged. The burner may be cleaned with soap and hot water

(Figure 24B).

Figure 24B

L.P. Gas Burner/

Manifold Burner Assembly

Manifold Door

Gasket_

Manifold Component

B urner......._

Block__

Screws

-""--_/ anifold Tube

Manifold Door

Assembly

/

Thermal Switch

/

_

Igniter Wire

_

-%

.

A

_

"_, j_\\_.

_/

_'--_

//_Pilot

/

Tube

Manifold

Outer Door]

Not ShownJ

Manifold Screw (2)--

.Manifold Door

Manifold Component Block

Pilot Assembly

Thermopile

Retainer Clip

Pilot Bracket

y Thermopile

23

Replacing the Pilot/Thermopile Assembly

1.

Remove the manifold assembly as directed previously.

2.

Lift the retainer clip straight up from the back of the manifold component block (using a fiat-blade screwdriver), then remove the manifold component block from the manifold door (Figure 25).

Figure 25

Manifold Component

Block Assembly

Thermopile

Connector

,

_

Burner and other fittings not show for clarity.

Wire

Manifold Door

3.

Locate and remove the screws on the underside of the burner, then remove the burner. IMPORTANT: DO NOT remove the orifice. LP Cast Burner models DO NOT require the burner to be removed. Remove the screw securing the pilot assembly to the manifold.

NOTE: For cast burner models, remove the screw securing the pilot assembly to the burner.

4.

Using a 7/16" wrench, loosen the nut securing the pilot tube to the pilot assembly.

NOTE: To prevent any bending of the pilot bracket, use pliers to hold the pilot assembly bracket while loosening the pilot nut.

Figure 26

Pilot/Thermopile Assembly

Pilot

_nintere/_

Pilot/Thermopile

Assembly

NOTE: See figure 24A for correct burner orientation.

10. Position the new thermopile wires through the top opening of the manifold component block (Figure 25). Be sure the igniter wire is positioned through the middle opening of the manifold component block.

11. See "Replacing Manifold Assembly" Page 25.

Filter Installation

and Cleaning

IMPORTANT: It is essential that the filter be installed properly.

If you encounter difficulty installing the filter or have a question, please call the Service & Warranty Department at 1-877-817-6750.

Filter Installation

1.

Before attaching the filter, remove any dust or debris that may have accumulated in the installation area. It is also recommended that a visual inspection of the flame-trap be performed. Refer to the "External Inspection & Cleaning of the Flame-trap" section.

2.

Connect the end points of the filter sections together (see

Figure 27) to form one long section. Wrap this section around the base of the water heater and join at the closest connection point to fit your water heater. NOTE:

If your water heater has a small diameter tank it may be necessary to use both inner connection points).

3.

Once connected, check to ensure a close fit with no gaps between the water heater, the filter, and the floor

(see Figure 27). NOTE: Depending on the size of your water heater, the filter may have some excess material.

This may be trimmed away.

4.

It is recommended that the filter be inspected periodically to maintain unrestricted airflow to the water heater.

Periodic Cleaning of the Filter

1.

If periodic inspection of the filter shows a build-up on the filter, it should be removed and cleaned.

2.

To remove the filter, locate a set of connection posts (see

Figure 27) and squeeze them together while pulling outward on the thumb tab.

3.

The filter can then be vacuumed to remove the build-up.

4.

Before re-attaching the filter, a visual inspection of the flametrap is recommended. Refer to the "Extemal Inspection &

Cleaning of the Flame-trap" section.

5.

Follow Filter Installation instructions 2-3 to re-attach the filter.

Figure 27

Flame-trap visual inspection & filter installation/removal

Flashlight Mirror

Thermal

Switch

_f 7_ X

D

Wire

5.

Disconnect the red wire connected to the thermal switch, then lift the pilot/thermopile assembly (including the igniter wire) from the manifold assembly.

6.

Pull the pilot tube from the pilot assembly (Figure 26).

IMPORTANT: Be careful not to bend or alter the position of the pilot assembly components.

7.

Using the old pilot/pilot tube assembly as a guide, bend the new pilot tube to match the old one. Make only the bends closest to the pilot before going to the next step.

8.

Push the new pilot assembly connectors through the hole in the manifold door (See Figure 25). Reconnect the pilot tube and tighten the nut securing it to the pilot assembly.

IMPORTANT: Keep the pilot orifice in the pilot when

, making the connection. DO NOT operate the water heater without the pilot orifice installed. Reattach the pilot assembly to the manifold. Cast burner models reattach the pilot assembly to the burner.

Reattach the burner and secure with screws.

24

External

/

Posts

Inner Connection Points "Outer Connection Points

Inspection

& Cleaning

of the

Flame-trap

Although not likely to occur, if debris collects on the flametrap, use a vacuum, compressed air, or a soft bristle brush to remove it.

NOTE: If unable to inspect or clean the flame trap from underneath, follow the "Cleaning the Combustion Chamber and Flame-trap" section instructions.

Cleaning the Combustion Chamber and

Flame-trap

1.

Follow procedure outlined in "Removing the Manifold

Assembly".

2.

Use a vacuum cleaner/shop vac to remove all loose debris in the combustion chamber (Figure 28A). Use compressed air to clear any dust or debris that may have accumulated in the flame-trap.

3.

Reassemble following the procedure under "Replacing the Manifold Assembly".

Replacing the Manifold Assembly

9.

Check for leaks by brushing on an approved noncorrosive leak detection solution. Bubbles forming indicate a leak. Correct any leak found. IMPORTANT:

All leaks must be fixed immediately.

10. Replace the outer door.

Figure 28A

Combustion Chamber

Figure 28B

Manifold Assembly Close-up

Close-up inside view of the combustion chamber.

Explosion Hazard

Tighten both manifold door screws securely.

Remove any fiberglass between gasket and combustion chamber.

Replace viewport if glass is missing or damaged.

Replace two piece wire connector if missing or removed.

Replace door gasket if damaged.

Failure to follow these instructions can result in death, explosion, or fire.

Check the door gasket for damage or imbedded debris prior to installation.

2.

Inspect the viewport for damage and replace as required.

3.

Insert the manifold assembly into the burner compartment making sure that the tab of the manifold tube engages in the slot of the bracket inside the combustion chamber (Figure 28B).

4.

Inspect the door gasket and make sure there is no fiberglass insulation between the gasket and the combustion chamber.

5.

Replace the two screws which secure the manifold assembly door to the combustion chamber and tighten securely. There should be no space between the gasket part of the manifold door and combustion chamber. IMPORTANT: Do not operate the water heater if the door gasket does not create a seal between the manifold door and the combustion chamber.

6.

Reconnect the red wire leads to the thermal switch

(Figure 25), the manifold tubing (3/4" wrench), pilot tubing (7/16" wrench), and thermopile wires to the gas control valve/thermostat.

(See Figure 22 for the correct position of the thermopile wires.) Do not cross-thread or apply any thread sealant to the fittings.

NOTE: L.R Gas systems use reverse (left-hand) threads on the manifold tube.

7.

Reconnect the igniter wire.

8.

Turn the gas supply on and refer to the "Lighting

Instructions" on page 17.

Manifold Tube_

Piezoelectric Igniter System

The piezoelectric igniter system consists of the igniter button, electrode, and wire. The pilot is ignited by an electric spark generated when the igniter button is pressed.

(See Figure 29). Use only factory authorized piezoelectric igniter parts for replacement.

Figure 29

Gas Igniter Assembly

-/Igniter Button

Electrode

)ile

Bracket

Testing the Igniter System

Turn off the gas to the water heater at the manual gas shutoff valve. Watch the electrode tip while activating the igniter.

A visible spark should jump from the electrode. To avoid shock, do not touch the burner or any metal part on the pilot or pilot assembly. If no spark is visible, check the wire connections and make sure the electrode is not broken.

Replace the igniter if defective. Dirt and rust on the pilot or electrode tip can prevent the igniter spark. Wipe clean with a damp cloth and dry completely. Rust can be removed from the electrode tip and metal surfaces by lightly sanding with an emery cloth or fine grit sandpaper.

25

Removing and Replacing the Gas

Control Valve/Thermostat

IMPORTANT: The gas control valve/thermostat is a standard valve with wire leads that connect to a thermal switch.

Removing the Gas Control Valve/Thermostat:

1.

Turn the gas control/temperature knob to the "OFF" position (Figure 19A).

2.

Turn off the gas at the manual shut-off valve on the gas supply pipe (Figure 3).

3.

Drain the water heater. Refer to the section of "Draining and Flushing" and follow the procedure.

4.

Disconnect the igniter wire from the igniter lead wire. Use needle nose pliers to disconnect the red (+) and white (-) thermopile wires. Disconnect pilot tube (7/16" wrench) and manifold tube (3/4" wrench) at the gas control valve/ thermostat (Figure 22). NOTE: L.R Gas systems use reverse (left-hand) threads on the manifold tube.

5.

Refer to "Gas Piping" (Figure 3) and disconnect the ground joint union in the gas piping. Disconnect the remaining pipe from the gas control valve/thermostat.

6.

To remove the gas control valve/thermostat, thread a 4" section of gas pipe into the inlet and use it to turn the gas control valve/thermostat (counterclockwise.) Do not use pipe wrench or equivalent to grip body. Damage may result, causing leaks. Do not insert any sharp objects into the inlet or outlet connections.

Damage to the gas control valve/thermostat may result.

Gas Control Valve/Thermostat:

To replace the gas control valve/thermostat, reassemble in reverse order. When replacing the gas control valve/ thermostat, thread a 4" section of gas pipe into the inlet and use it to turn the gas control valve/thermostat (clockwise.)

DO NOT OVER TIGHTEN, damage may result.

• Be sure to use approved Teflon® tape or pipe joint compound on the gas piping connections and fitting on the back of the gas control valve that screws into tank.

• Be sure to remove the pilot ferrule nut from the new gas control valve/thermostat.

• Turn the gas supply on and check for leaks. Test the water heater by brushing on an approved noncorrosive leak detection solution. Bubbles forming indicate a leak.

Correct any leak found.

• Be sure tank is completely filled with water before lighting and activating the water heater. Follow the

"Lighting Instructions" on page 17.

• If additional information is required, contact the Service

Department at: 1-877-817-6750.

Flame Lock ® Safety System

Operational

Checklist

1.

Manifold gasket properly sealed.

2.

Viewport not damaged or cracked.

3.

Flame-trap free of debris and undamaged.

4.

Manifold component block properly installed.

5.

No leaks at pilot and manifold connection.

6.

Manifold door screws securely tightened.

7.

Depress the button on the thermal switch.

TROUBLESHOOTING CHART

PROBLEM

POSSIBLE CAUSE(S)

BURNER WILL NOT IGNITE

1.

Pilot not tit

2.

Thermostat set too low

3.

No gas

4.

Dirt in the gas lines

5.

Pilot line clogged

6.

Main burner line clogged

7.

Non-functioning thermopile

8.

Non-functioning thermostat

9.

Heater installed in a confined area

SMELLY WATER

BURNER FLAME YELLOW-

LAZY

1.

Sulfides in the water

1.

Insufficient secondary air

2.

Low gas pressure

3.

Flue clogged

4.

Main burner line clogged

5.

Heater installed in a confined area

6.

Obstruction in main burner orifice

PILOT WILL NOT LIGHT OR

REMAIN LIT

1.

Non-functioning igniter

2.

The thermal switch tripped

3.

Thermopite connection loose

4.

Air in gas line

5.

Proper Lighting Sequence not followed.

Gas Control / Temperature Knob was not held in for sufficient time.

6.

Low gas pressure

7.

No gas

8.

Dirt in gas lines

9.

Cold drafts

10. Thermostat ECO switch open

CORRECTIVE

ACTION

1.

Light pilot

2.

Turn temp. dial to desired temperature

3.

Check with gas utility company

4.

Notify utility-install trap in gas line

5.

Clean, locate source and correct

6.

Clean, locate source and correct

7.

Replace thermopile

8.

Replace thermostat

9.

Provide fresh air ventilation

1.

Replace the anode with a special anode

1.

Provide ventilation to water heater

2.

Check with gas utility company

3.

Clean, locate source and correct

4.

Clean, locate source and correct

5.

Proper fresh air ventilation

6.

Clean or replace orifice

1.

Replace igniter pilot assembly

2.

See Pilot Light Troubleshooting Flowchart section

3.

Seat connector firmly in socket

4.

Bleed the air from the gas line

5.

Do not attempt to relight if the red light is lit and the pilot flame is not visible through the view port. Wait until the red light is no longer lit, then follow lighting instructions on the water heater.

6.

Check with gas utility company

7.

Check with gas utility company

8.

Notify utility-install dirt trap in gas line

9.

Locate source and correct

10. Replace thermostat

26

PROBLEM

PILOT WILL NOT LIGHT OR

REMAIN LIT (continued)

POSSIBLE CAUSE(S)

11. Pilot line or orifice clogged

12. Non-functioning thermopite

13. Air for combustion obstructed

HIGH OPERATION COSTS

INSUFFICIENT HOT WATER

14. Flammable vapors incident, Flame Lock _ function utilized

1.

Thermostat set too high

2.

Sediment or time in tank

3.

Water heater too small for job

4.

Wrong piping connections

5.

Leaking faucets

6.

Gas leaks

7.

Wasted hot water

8.

Long runs of exposed piping

9.

Hot water piping in exposed wall

1.

Thermostat set too tow

2.

Sediment or time in tank

3.

Water heater too small

4.

Wrong piping connections

5.

Leaking faucets

6.

Wasted hot water

7.

Long runs of exposed piping

8.

Hot water piping in outside wall

9.

Low gas pressure

1.

Insufficient secondary air

SLOW HOT WATER

RECOVERY

2.

Flue clogged

3.

Low gas pressure

4.

Improper calibration

5.

Thermostat set too tow

6.

Water heater too small

7.

Wrong piping connections

8.

Wasted hot water

DRIP FROM RELIEF VALVE 1.

Excessive water pressure

2.

Heater stacking

3.

Closed water system

THERMOSTAT FAILS TO

SHUT-OFF

1.

Thermostat not functioning properly

2.

Improper calibration

COMBUSTION ODORS 1.

Insufficient secondary air

2.

Flue clogged

3.

Heater installed in a confined area

1.

Insufficient secondary air SMOKING AND CARBON

FORMATION (SOOTING)

CONDENSATION

BURNER FLAME FLOATS

AND LIFTS OFF PORTS

2.

Low gas pressure

3.

Flue clogged

4.

Thermostat not functioning properly

5.

Heater installed in a confined area

6.

Burner flame yellow-lazy

1.

Temperature setting too low

1.

Orifice too large

2.

High gas pressure

3.

Flue clogged

4.

Cold drafts

BURNER FLAME TOO HIGH 1.

Orifice too large

FLAME BURNS AT ORIFICE 1.

Thermostat not functioning properly

2.

Low gas pressure

PILOT FLAME

TOO SMALL

1.

Pilot line or orifice clogged

2.

Low gas pressure

CORRECTIVE ACTION

11. Clean, locate source and correct

12. Replace thermopite

13. See maintenance section for inspection and cleaning of flame trap

14. Replace water heater, eliminate flammable vapors source.

Call 1-877-817-6750

1.

Set temperature dial to lower setting

2.

Drain/flush-provide water treatment if needed

3.

Install adequate heater

4.

Correct piping-dip tube must be in cold inlet

5.

Repair faucets

6.

Check with utility-repair at once

7.

Advise customer

8.

Insulate piping

9.

Insulate piping

1.

Turn temperature dial to desired setting

2.

Drain/flush-provide water treatment if needed

3.

Install adequate heater

4.

Correct piping-dip tube must be in cold inlet

5 Repair faucets

6.

Advise customer

7.

Insulate piping

8.

Insulate piping

9.

Check with gas utility company

1.

Provide ventilation to water heater. Check flue way, flue baffle, and burner

2.

Clean flue, locate source and correct

3.

Check with gas utility company

4.

Replace thermostat

5.

Turn temperature dial to desired setting

6.

Install adequate heater

7.

Correct piping-dip tube must be in cold inlet

8.

Advise customer

1.

Use a pressure reducing valve and relief valve

2.

Lower the thermostat setting

3.

See "Closed System/Thermal Expansion"

1.

Replace thermostat

2.

Replace thermostat

1.

Provide ventilation to water heater. Check flue way, flue baffle, and burner

2.

Clean, locate source and correct

3.

Provide fresh air ventilation

1.

Provide ventilation to water heater. Check flue way, flue baffle, burner

2.

Check with gas utility company

3.

Clean, locate source and correct

4.

Replace thermostat

5.

Provide fresh air ventilation

6.

See "Burner Flame Yellow-Lazy"

1.

Increase the temperature setting

1.

Replace with correct orifice

2.

Check with gas utility company

3.

Clean flue and bumer-locate source and correct

4.

Locate source and correct

1.

Replace with correct orifice

1.

Replace thermostat

2.

Check with gas utility company

1.

Clean, locate source and correct

2.

Check with gas utility company

27

STATUS LIGHT CODE TROUBLESHOOTING

CHART

LED STATUS

0 FLASHES (LED NOT LIT)

1 FLASH (EVERY 3 SECONDS)

2 FLASHES

4 FLASHES

5 FLASHES

7 FLASHES

8 FLASHES

PROBLEM CORRECTIVE ACTION

Pilot light is not lit. Not enough power (mitlivolts) to keep it lit.

Follow the lighting instructions on the front of the water heater and record any diagnostic codes.

See Diagnostic Status Light Code section.

Normal operation.

No corrective action necessary.

Insufficient power (mitlivolts) to the 1.

Check all wiring connections.

If problem gas control valve/thermostat, persists proceed to step 2.

2.

Replace the thermopite. See "Replacing the

Pitot/Thermopite Assembly."

High water temperature has activated the over heat sensor.

Replace the gas control valve/thermostat.

See

"Removing and Replacing the Gas Control Valve/

Thermostat."

Sensor failure Replace the gas control valve/thermostat.

See

"Removing and Replacing the Gas Control Valve/

Thermostat."

Gas Control Valve/Thermostat failure.

This condition only appears if the gas control/temperature knob has been turned off and the thermopite continued to produce electric power.

This condition can occur if the thermopite does not cool down as quickly as expected when the unit is shut off.

This condition can also occur if the gas control/ temperature knob has been turned off and the pilot continues to operate because the pilot valve is stuck in the open position.

Replace the gas control valve/thermostat.

See

"Removing and Replacing the Gas Control Valve/

Thermostat."

Make sure that the gas control valve/thermostat knob is set to OFF.

Wait one minute.

Remove the outer door.

Look through the sight glass for a pilot flame.

If a pilot flame is observed with the gas control valve/thermostat knob set to the OFF position, the pilot valve is stuck open. Turn the main gas supply OFF.

Replace the gas control valve/ thermostat.

For instructions, see "Removing and

Replacing the Gas Control Valve/Thermostat."

If the pilot flame is not observed when the gas control valve/thermostat knob is set to the OFF position, wait 10 minutes for the thermopite to coot, then attempt to relight the pilot by following the lighting instructions on the water heater's label. If this condition returns, replace the gas control valve/ thermostat.

See "Removing and Replacing the Gas

Control Valve/Thermostat" for instructions.

28

PILOT LIGHT TROUBLESHOOTING CHART

Section A: Pilot light will not light (new installation).

Section C: Pilot light will not remain lit.

Check for insufficient combustion air. m

Is the manual gas shut-off valve, / located in the supply line to the

•lTurn

IN NO _lthe the manual gas shut-off valve to on position and follow the lighting

I

I

" minstructi°ns °n the fr°nt °f the water heater" m

YES

Have you bled all the air from the pilot tube and

[gas supp y ne?

/

YES

• IWhile repeatedly depressing the igniter

IN NOmll_lbutton, push in and hold the gas control/

| a

--Itemperature

maintains knob until the pilot is lit and a stable flame, (status light will blink) then release the gas control/ temperature knob.

Are the combustion air supply and ventilation openings • ICorrect size of of sufficient size? See "Combustion Air Supply and

Ventilation" section in this manual for requirements.

Y_S

÷

m NOmlpIopenings to allow

|surf cent a r.

mNOmlls there a furnace/air handler in the same room as the water heater? I

YES

Is S 0nte' r° ucin0a !

Follow the "Testing the Igniter

System sect on n th s manual.

I lSet thermostat to desired temperature" J

Section B: Pilot light repeatedly goes out.

_lls

Does the return air duct for the furnace/ air handler draw its air from a separate location than the water heater? See the

"Location Requirements" section and the "Combustion Air Supply" section.

NNO_

IContact a local Heating, I

• IVentilation, Air-Conditioning I

1& Refrigeration authorized I

|

I lthe service pr°vider t° c°rrect I combustion air supply/ I ventilation issue, I YES

÷

there proper drafting at the | ICheck the vent drafthood?

See "Checking thelm NO mll_sY stem for restrictions/

IDraft" section in this manual.

| Y Iobstructions and check y--_ |the vent termination

II

II

II

|height.

|"installation

|section

Refer to the

Instructions" of this manual for

/ specific requirements.

I Contact Customer Service at 1-877-817-6750.

I

Remove the burner door assembly. Are the flame-trap and burner free from debris due to excessive lint, dirt, dust or oil?

YES

,!, 4,

Refer to the "Maintenance of /

==NO ikl

.

.

.

L lip manual for informatlon on cleanlng | the flame-trap and burner.

/

I II

NOTE: If you are still experiencing difficulties after following the steps in sections A, B, and C, please contact Customer Service at 1-877-817-6750.

Does the flame-trap IN show signs of d sco orat on?

/

Reassemble the heater, press the thermal I

NON_, switch, and attempt to return the heater to serv ce. Does the pot rema n t?

YES YES m

NO

Shut-off the gas supply to the water heater at the manual gas shut-off valve, and contact Customer

Serv ce at 1-877-817-6750

I

I /

!

ISet to desired temperature.

I

Figure 30

Thermal Switch Location

Go to section C. I

Does the diagnostic status light on the gas control valve/thermostat give a two fash error code?

YES

",I,

Refer to the "Replacing the Pilot

Assemby nstructons n the manua.

I

!

I

I Reassemble and restore to service. I

29

REPAIR PARTS ILLUSTRATION

When ordering repair parts always give the following information:

1.

Model, serial, and product number

2.

Type of gas

3.

Item number

4.

Parts description

Repair Parts List

Item

No.

1

2

3

4

Parts Description

DRAFT HOOD

REDUCER RING - SOME MODELS

FLUE BAFFLE

HEAT TRAP (COLD) - SOME MODELS

7

8

5

6

9

10

HEAT TRAP (HOT) - SOME MODELS

COLD WATER DIP TUBE

ANODE ROD

TEMPERATURE & PRESSURE RELIEF VALVE

(LOCATED TOP OR SIDE)

DRAIN VALVE

GAS CONTROL VALVE/TH ERMOSTAT

(with thermal switch wire lead)

CONTROL MODULE

10

_r

-_

11 OUTER DOOR

12A* PILOT/THERMOPILE ASSEMBLY KIT

12B* PILOT/THERMOPILE ASSEMBLY KIT ( L.R Cast Bumer)

13A* BURNER (Natural Gas/Low Nox)

13B* L.R CAST BURNER

-_

14A* MANIFOLD DOORASSEMBLY

14B* MANIFOLD DOORASSEMBLY (L.R

Cast Burner)

15" MANIFOLD COMPONENT BLOCK

16" MANIFOLD DOOR GASKET

17" VIEWPORT ASSEMBLY

"_

*Pictured on next page.

3O

LEGEND

• Special anode rod (see page 21)

Temperature and Pressure Relief Valve is required,

• but may not be factory installed

Unique: Flame Lock ®Safety System parts

Listed

Item 12:

Item 12:

Item 13:

Parts Kits and Illustrations

Pilot assembly kit, which contains the pilot assembly, thermopile, and retainer clip (Natural Gas)

Pilot assembly kit, which contains the pilot assembly, thermopile, and retainer clip (L.P. Gas)

Item 13:

Burner (Natural Gas/L.R Gas)

Burner (L.R Gas)

Item 14:

Item 14:

Manifold door assembly which contains the manifold tube, gasket, door, pilot tube, thermopile, manifold component block with retainer clip, thermal switch, and pilot assembly. (Natural Gas/Low Nox)

Manifold door assembly which contains the manifold tube, gasket, door, pilot tube, thermopile, manifold component block with retainer clip, thermal switch, and pilot assembly. (L.P. Gas)

Item 15:

Item 16:

Contains manifold component block and retainer clip

Contains manifold door gasket

Item 17:

Contains viewport

Item #12A Item #12B

Item #13A Item #13B

Item #14A Item #14B

L.P. BURNER

Item #15 Item #16

Item #17

31

Warrantyprovidedby Manufacturer.

advertisement

Key Features

  • Flame Lock® Safety System for added safety and peace of mind
  • Durable construction for long-lasting performance
  • Energy-efficient design to save on energy costs
  • Compact design for easy installation in tight spaces
  • Easy-to-use temperature control system for customized hot water temperatures
  • High recovery rate for continuous hot water availability

Related manuals

Frequently Answers and Questions

What is the Flame Lock® Safety System?
The Flame Lock® Safety System is a safety feature that automatically cuts off the gas supply if the flame goes out, preventing gas leaks and potential hazards.
Is the water heater energy-efficient?
Yes, the water heater is designed to be energy-efficient, helping you save on energy costs.
Is the water heater easy to install?
Yes, the water heater is designed for easy installation in tight spaces.

advertisement