Built-In 27" & 30"
Electric Wall Ovens
G
I
H
E
F
C
D
+I'M _"]l+[+"]!4_+vl_!l[,_VJ=l+l
1 1/4" Dia.Conduit AccessHole*
A
B
2 5/8" PlywoodFloor (MustSupport200 ibs.)
DIMENSIONS inches cm
27 MIN
24 MIN
68.58
60.96
29 1/16+_1/16
24 MIN
25 1/2+ 1/16
29 1/2
73.82
60.96
64.77
74.93
26 3/4
25 7/16
4 to 31
67.95
64.61
10.2to 78.7
2
C
D
A
B
E
F
I
G
H
1 1/4" Dia.Conduit AccessHole*
5/8" PlywoodFloor (MustSupport200Ibs.)
DIMENSIONS inches
30 MIN
24 MIN
29 1/16+1/16
24 MIN
28 1/2+1/16
29 1/2
29 3/4
25 7/16
4 to 31
=JENN-AIR
NEWTON, IA 50208
NORTH
Art #: 9220-025
DOUBLE WALL OVEN
G
I
H
E
F
C
D
1 1/4" Dia.Conduit AccessHole*
A
B
2 5/8" PlywoodFloor(MustSupport310 Ibs.)
DIMENSIONS inches cm
27 MIN
24 MIN
68.58
60.96
51 7/8+1/16
24 MIN
25 1/2+ 1/16
52 1/4
26 3/4
25 1/2
4 to 10
131.76
60.96
64.77
132.72
67.95
64.77
10.2to 25.4
C
D
G
I
H
E
F
1 1/4" Dia. ConduitAccessHole*
A
B
2 5/8" PlywoodFloor (MustSupport310 Ibs.)
DIMENSIONS inches cm
30 MIN
24 MIN
76.20
60.96
51 7/8+_1/16
24 MIN
28 1/2+_1/16
52 1/4
29 3/4
25 1/2
4to10
131.76
60.96
72.39
132.72
75.57
64.77
10.2to 25.4
Y
W
I_[e]id_l
Donot blockairexhaustslotsalong bottom of oven.
Gas or electric cooktopsmay be installed overovens. Seecooktopinstallation instructionsfor cutout size.**
Electricalconnectionfor electric cooktop mustinadjacentaccessiblelocation.Cook
top and wall oven must be on separate
120/240or 120/208volt60 HzAC circuits.
CAUTION
For European style cabinets (flush front) the required clearance for operation of the oven door minimum spacing of 7/8" between is the cutout and the door.
hinge or drawer of the cabinet.
Some built-in cabinets may not be wide enough, due to their construction to allow this installation.
I
G
H
E
F
1 1 1/4" Dia.Conduit AccessHole*
2 5/8" PlywoodFloor (MustSupport200 Ibs.)
DIMENSIONS inches cm
A
B
25
24 MIN
63.50
60.96
C
D
29 1/16+_1/16
24 MIN
73.82
60.96
28 1/2
29 1/2
29 3/4
25 7/16
36
72.39
74.93
75.57
64.61
91.44
J 1 1/2 3.81
AiI JA Cooktops
NOTE: * Holemust becut as closeto cornerof cabinetas possible.
** See dealerfor approvedcooktops.
cm
7.62 MAX
J
Art #: 9220-027
'.-Z
UNDER COUNTER WALL OVEN
See pages 5, 6 and 7 for detailed installation instructions.
8101 P602-60
(11-03-00)
1
Built-In 27" & 30" Electric
Combination Wall Ovens
JENN-AIR
403 WEST FOURTH STREET, NORTH
NEWTON, IA 50208
A
B
C
D
E
F
G
I
H
1-1/4" Dia. Conduit Access Hole*
5/8" Plywood Floor (Must Support 275 Ibs.)
DIMENSIONS in
27 MIN
24 MIN
51-7/8 + 1/16
24 MIN
25-1/2 + 1/16
52-15/16
26-3/4
25-7/16
4 to 10 cm
68.58
MIN
60.96
MIN
131.76+.16
60.96
MIN
64.77
+ .16
134.46
67.95
64.61
10.2 to 25.4
* Hole must be cut as close to corner of cabinet as possible.
Do not block air exhaust slots along bottom of oven.
COMBINATION
A
B
C
D
I
H
E
F
G
1-1/4" Dia. Conduit Access Hole*
5/8" Plywood Floor (Must Support 275 Ibs.)
DIMENSIONS in
30 MIN
24 MIN
51-7/8 + 1/16
24 MIN
28-1/2 + 1/16
52-15/16
29-3/4
25-7/16
4 to 10 cm
76.20
MIN
60.96
MIN
131.76+.16
60.96
MIN
72.39
+ .16
134.46
75.57
64.61
10.2 to 25.4
CAUTION
For European style cabinets (flush front) the reauired clearance for operation of the oven door is minimum spacing of 7/8" between the cutout and the door. hinge or drawer of the cabinet.
Some built-in cabinets may not be wide enough, due to their construction, to allow this installation.
WALLOVEN CUTOUT
NOTE:
INSTALLED WALL OVEN OVERLAPS
CUTOUT 15/16" (2.38 CM) AT THE
TOP AND 1/8" (0.32 CM) AT THE
BOTTOM.
THIS MUST BE TAKEN INTO
CONSIDERATION WHEN LOCATING
CUTOUT IF INSTALLED UNIT IS TO
BE CENTERED IN THE CABINET.
f
[
Art #: 9220-028
Installing Bottom Trim Piece
Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, if doubt exists as whether the appliance is properly grounded.
CAUTION
For European style cabinets (flush front) the required clearance for operation of the oven door is min mum spacing of 7/8" between the cutout and the door, hinge or drawer of the cabinet.
Some bui t-in cabinets may not be wide enough, due to their construction, to allow this installation.
Installation
1. Cut hole in cabinet to mount oven. Cutout in cabinet should be level and straight.
NOTE: There are no provisions to level the unit after it is installed. An oven that is not level could cause poor baking results.
2. Install plywood floor as shown.
3. Remove oven door(s). See Oven Door Removal procedure.
4. Attach unit to the cabinet with four No. 8 x 1" screws supplied with unit inside of envelope containing these instructions. Pre-drill holes in cabinet for attachment screws using 1/8" drill. Oven mounting holes are provided in side trim.
5. Install bottom trim.
6. Replace oven door(s). See Oven Door Replacement procedure.
7. See instructions at right for electrical hook-up.
8. See Use and Care Manual for operating instructions.
Remove lower screws from hinge receptacle plates.
Align lower trim and reinstall screws.
DO NOT INSTALL BOTTOM TRIM UNTIL UNIT IS
ATTACHED TO THE CABINET.
Electrical Connections
Unit to be properly circuit protected and wired according to local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be accomplished by a competent electrician.
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on front of unit for power requirements.
The neutral of this unit is grounded to the frame through the solid grounding wire. (The ground and the white wires are twisted together at the termination of the conduit.) If used on new branch-circuit installations (1996 NEC), mobile homes, recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor, untwist or disconnect the ground wire and connect to ground in accordance with local code. Connect the white neutral to the service neutral. Connect all wires to the branch circuit with approved connectors.
Use copper or aluminum wire. If aluminum wire is used, use connectors recognized for joining aluminum to copper.
The chart below recommends the minimum circuit protection and wire size if the appliance is the only unit on the circuit.
K.W. RATING
ON SERIAL PLATE
0 4.8
4.9 6.9
7,09.9
10.0 - 11.9
12.0 - 14.9
RECOMMENDED MINIMUM
CIRCUIT PROTECTION
IN AMPERS
20
30
40
50
60
WIRE SIZE
(AWG)
12
10
8
8
6
Service
Interrupt the source of electricity to the unit when attempting to repair or service the oven. Failure to do this could result in a dangerous or even fatal shock.
IMPORTANT - SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE
Oven Door Removal
For ease of installation, remove oven door(s) before placing unit into cutout. This will reduce the weight of the unit by about 35 pounds per door.
Remove oven door(s) as follows:
• Open oven door to the "Full Open" position (see
Figure 1).
• Rotate hinge locking lever DOWN, to unlock hinge from the unit (see Figure 2).
• Close oven door to the "Removal" position (until it stops; see Figure 3).
• Grasp the door firmly on each side and lift the door straight up and off the unit.
NOTE: The oven door is heavy.
Be sure you have a firm grip before lifting the oven door off the unit.
Do not lift the door by the handle!
Hinge Locking Lever
(Locked Position
Figure 1
Oven Door Replacement
Replace oven door(s) after placing unit into cutout.
Replace oven door(s) as follows:
• Grasp oven door firmly on each side, hold oven door at approximately a 30 ° angle and align oven door hinge arm (see Figure 4) with hinge receiver on unit
(see Figure 5).
• Insert oven door hinge arm into hinge receiver until the hinge arm slots (see Figure 4) align with horizontal pins on the hinge receiver (see Figure 5) and place hinge arm onto the hinge receiver.
• Once the hinge arms are resting on the hinge receiver pins (see Figure 3) open oven door slowly to the "Full
Open" position (see Figure 2).
• Rotate hinge locking lever UP to the locked position to secure the oven door to the unit (see Figure 1).
NOTE: Make sure that hinge locking lever is rotated fully
UP to the locked position as shown (see Figure 1 ) before closing oven door.
CAUTION
Door will not close all the way and Could fall off when opened if the hinge locking lever s are not
rotated fu y UP to the ocked pos t on.
If hinge locking lever will not rotate fully UP to the locked position as shown (see Figure 1) then the hinge arm is not properly seated on the receiver. Rotate the hinge locking lever DOWN to the unlocked position (see Figure
2) and remove oven door as outlined in the Oven Door
Removal procedure. Then replace the oven door as outlined in the Oven Door Replacement procedure, making sure that the hinge arm slots are fully seated on the horizontal pins in the hinge receiver.
• Once the hinge locking lever is rotated fully UP to the locked position (see Figure 1) close the oven door.
ge Locking Lever
Jnlocked Position)
3ge Arm
Hinge Arm Slots
Receiver
Horizontal Pins
Figure 5
Figure 3
30" Under Counter
Wall Oven
2
!
E
C
D
J
A
B
1-1/4" Dia. Conduit Access Hole*
5/8" Plywood Floor (Must Support 200 Ibs.)
See next page for Support Platform Construction inches
DIMENSIONS
25 cm
63.50
24 MIN 60.96
29-1/16 +_1/16
24 MIN
28-1/2
36
1-1/2
73.82
60.96
72.39
g1.44
3.81
=JENN-AIR
NORTH
NEWTON, IA 50208
1
inches
3 MAX cm
7.62MAX
Y
W
Donot blockair exhaustslotsalong bottomof oven.
Gasor electriccooktopsmay beinstalledoverovens.**
See cooktopinstallationinstructionsfor cutoutsize.
Electricalconnectionfor electriccooktopmustin adjacentaccessiblelocation.Cooktop andwall oven mustbe on separate120/240or 120/208volt
60 Hz ACcircuits.
NOTE: * Holemustbe cut as closeto cornerof cabinet as possible.
• * Seedealerfor approvedcooktops.
A
J
\
SIDEAND/ORTOP FILLERS
MAYBE NECESSARYIF UNIT
IS POSITIONEDBETWEEN
EXISTINGCABINETS.BE
SURETHEYARE ATTACHED
SECURELY,SINCETHEYWILL
ANCHORTHE OVENIN THE
CABINET.
9Z20-008
28-I/4
24
DISTANCE FROM REAR CABINET WALL TO iNSIDE OF CABINET KICK PLATE MINUS t18"
NOTE: THIS DIMINSION VARRIES
DEPENDING ON CABINET CONSTRUCTION
Z4-7/16 t
PAINT BLACK (OPTIONAL}
TOP SURFACE AND SIDE EDGES OF PLYWOO[
€
PLYWOOD
IF UNIT
CABINETS.
CABINET
IS POSITIONED BETWEEN
IT MAY BE NECESSARY
KiCK PLATE TO SUPPORT
DO NOT ADD IF CABINET
UNDER THE WALLOVEN
HAS
CUT-OUT
A KICK
EXISTING
TO ADD A
PLATFORM,
PLATE f
9?20-009
3 MAX I
I
' /
PAINT BLACK (OPTIONAL)
FRONT EDGE OF PLYWOOD AND
FRONT OF KICK PLATE IF NEEDED
/,
Support Platform
30" Under Counter Wall Oven
COOKTOP SHOWN FOR REFERENCE ONLY.
SEE COOKTOP INSTALLATION INSTRUCTIONS FOR CUTOUT SIZE.
0
"
,l_ ,_,==
_= 0___.
I
3-13116 MAX
BURNEI_ BOX DEPTH
36' MIN
29-1/16 + 1/16
WALL OVEN CUT OUT
HEIGHT
!!ii
i!ii
!!ii
i!ii
9220-010
3" MAX
SUPPORT PLATFORM HEIGHT 1
+
30" Under Counter Wall Oven with Cooktop
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement