DRYER INSTALLATION INSTRUCTIONS

INSTRUCTIONS POUR L’INSTALLATION

DE LA SÉCHEUSE

Table of Contents

DRYER SAFETY ....................................................................... 2

INSTALLATION REQUIREMENTS ........................................... 4

Tools and Parts ..................................................................................4

LOCATION REQUIREMENTS .................................................. 5

ELECTRICAL REQUIREMENTS – U.S.A. ONLY ..................... 7

ELECTRIC DRYER POWER HOOKUP – CANADA ONLY ...... 8

GAS DRYER POWER HOOKUP .............................................. 8

INSTALL LEVELING LEGS ..................................................... 10

MAKE ELECTRICAL CONNECTION – U.S.A. ONLY ............ 11

Power Supply Cord Connection ...................................................11

4-Wire Power Supply Cord Connection ......................................12

MAKE GAS CONNECTION .................................................... 17

VENTING ................................................................................. 18

Venting Requirements ....................................................................18

Plan Vent System ............................................................................19

Install Vent System ..........................................................................20

CONNECT INLET HOSE ....................................................... 21

CONNECT VENT .................................................................... 22

LEVEL DRYER ........................................................................ 23

COMPLETE INSTALLATION CHECKLIST............................. 23

DOOR REVERSAL (OPTIONAL) ............................................ 24

Table des matières

SÉCURITÉ DE LA SÉCHEUSE .............................................. 30

EXIGENCES D’INSTALLATION ............................................. 32

Outillage et pièces ........................................................................32

EXIGENCES D’EMPLACEMENT ........................................... 33

SÉCHEUSE ÉLECTRIQUE RACCORDEMENT

À L’ALIMENTATION ÉLECTRIQUE –

CANADA SEULEMENT .......................................................... 36

RACCORDEMENT D’UNE SÉCHEUSE À GAZ .................... 37

INSTALLATION DES PIEDS DE NIVELLEMENT .................. 38

RACCORDEMENT AU GAZ ................................................... 39

ÉVACUATION ......................................................................... 40

Exigences concernant l’évacuation ................................. 40

Planification du système d’évacuation ............................ 41

Installation du système d’évacuation .............................. 42

RACCORDEMENT DU TUYAU D’ALIMENTATION

(MODÈLE À VAPEUR UNIQUEMENT) .................................. 43

RACCORDEMENT DU CONDUIT D’ÉVACUATION ............. 44

RÉGLAGE DE L’APLOMB DE LA SÉCHEUSE ..................... 45

ACHEVER L’INSTALLATION LISTE DE VÉRIFICATION ....... 45

INVERSION DE LA PORTE (FACULTATIF) ............................ 46

Para una version de estas instrucciones en español, visite

www.whirlpool.com

INSTALLATION NOTES

Date of purchase: ________________________________________

Date of installation: _______________________________________

Installer: _________________________________________________

Model number: ___________________________________________

Serial number: ____________________________________________

NOTES CONCERNANT L’INSTALLATION

Date d’achat: ____________________________________________

Date d’installation: ________________________________________

Installateur: ______________________________________________

Numéro de modéle: _______________________________________

Numéro de série: _________________________________________

W11183136B

W11183139B-SP

2

DRYER SAFETY

WARNING:

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury, death or property damage.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Clear the room, building, or area of all occupants.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas

Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National

Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, Part 1, CSA C22.1.

In the State of Massachusetts, the following installation instructions apply:

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gas fitter qualified or licensed by

■ the State of Massachusetts.

Acceptable Shut-off Devices: Gas Cocks and Ball Valves installed for use shall be listed.

A flexible gas connector, when used, must not exceed 4 feet (121.9 cm).

3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Tools needed for all installations:

Tools needed for gas installations:

8" (203 mm) or 10"

(254 mm) pipe wrench

8" (203 mm) or 10" (254 mm) adjustable wrench (for gas connections)

Flat-blade screwdriver #2 Phillips screwdriver

1/4" (6 mm) and

5/16" (8 mm) nut driver

(recommended)

Level

Pipe-joint compound resistant to propane gas

Parts supplied (all models):

Tape measure Pliers

Leveling legs (4)

Parts needed (steam models):

Utility knife Tin snips (new vent installations)

“Y” connector

2' (0.6 m) inlet hose

Caulking gun and compound (new vent installations)

Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench

Wire stripper

(direct wire installations)

Rubber washer 5' (1.52 m) inlet hose

Parts package is located in dryer drum. Check that all parts are included.

NOTE:

Do not use leveling legs supplied with dryer if installing with a pedestal or a stack kit.

Parts needed (not supplied with dryer):

■ Vent clamps

■ Vent elbows and vent work

4

Additional parts may be required, depending on your installation.

Check local codes. Check existing electrical supply and venting.

Read “Electrical Requirements” and “Venting Requirements” before purchasing parts.

If using a power supply cord:

Use a UL Listed power supply cord kit marked for use with clothes dryers. The kit should contain:

■ A UL Listed 30 A power supply cord, rated 120/240 V minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

■ A UL Listed strain relief.

Optional Equipment (not supplied with dryer):

Refer to your Use and Care Guide for information about accessories available for your dryer.

LOCATION REQUIREMENTS

Check code requirements. Some codes limit, or do not permit, installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

DRYER DIMENSIONS

Front view:

Side view:

Whirlpool

®

Models

You will need:

■ A location allowing for proper exhaust installation.

See “Venting Requirements.”

■ A separate 15 or 20 A circuit for a gas dryer or 30 A circuit for an electric dryer.

If using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer.

See “Electrical Requirements.”

Floor must support dryer weight of 200 lbs. (90.7 kg). Also consider weight of companion appliance.

■ Cold water faucets located within 4 ft. (1.2 m) of the water fill valves, and water pressure of 20–120 psi (138–827 kPa).

You may use your washer’s water supply by purchasing the necessary parts noted in “Parts needed.”

Level floor with maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended

Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.

■ For garage installation, place dryer at least 18" (460 mm) above floor. If using a pedestal, you will need 18" (460 mm) to bottom of dryer.

■ The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

IMPORTANT:

Do not operate, install, or store dryer where it will be exposed to water, weather, or at temperatures below

40°F (4°C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times.

Maytag

®

Models

*Approx. measurement

*Approx. measurement

5

Back view: Recommended installation clearances (dryer only):

Vent

Water inlet

(Steam Models Only)

Gas

*Approx. measurement

NOTE:

Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting

Requirements.”

Installation Clearances

For each arrangement, consider allowing more space for ease of installation and servicing, spacing for companion appliances, and clearances for walls, doors, and floor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

NOTE:

No other fuel-burning appliance can be installed in the same closet as a dryer.

Installation spacing for recessed area or closet installation

All dimensions show recommended and minimum spacing allowed.

■ Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line.

■ Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

■ For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required.

Louvered doors with equivalent ventilation openings are acceptable.

■ Companion appliance spacing should also be considered.

0" (0 mm) rear spacing is allowed for straight back venting only.

For steam models only, inlet hose must not be kinked.

Custom under-counter installation:

Mobile home – Additional installation requirements:

This dryer is suitable for mobile home installations.

The installation must conform to the Manufactured Home

Construction and Safety Standard, Title 24 CFR, Part 3280

(formerly the Federal Standard for Mobile home construction and

Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

Mobile home installations require:

■ Metal exhaust system hardware, available for purchase from your dealer. For further information, see “Assistance or

Service” in your Use and Care Guide.

■ Special provisions must be made in mobile homes to introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.

For mobile home installation of gas dryers:

■ Mobile Home Installation Hold-down Kit Part Number 346764 is available to order. For further information, see “Assistance or Service” in your Use and Care Guide.

6

ELECTRICAL REQUIREMENTS –

U.S.A. ONLY

It is your responsibility:

■ To contact a qualified electrical installer.

■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70

– latest edition and all local codes and ordinances.

The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from:

National Fire Protection Association, One Batterymarch Park,

Quincy, MA 02269.

■ To supply the required 3 or 4 wire, single-phase, 120/240 V,

60 Hz, AC-only electrical supply (or 3 or 4 wire, 120/208 V electrical supply, if specified on the serial/rating plate) on a separate 30 A circuit, fused on both sides of the line. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

■ Do not use an extension cord.

■ If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

If your outlet looks like this:

4-wire receptacle

(14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL Listed strain relief. The 4-wire power supply cord, at least

4 ft. (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of

NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

3-wire receptacle

(10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least

4 ft. (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of

NEMA Type 10-30R.

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

■ This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground conductor is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground conductor must be removed from the external ground connector (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground conductor is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor. The green ground wire of the 4-wire power cord must be secured to the dryer cabinet with the green ground screw.

■ If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional External Ground for

3-Wire Connection” in the “Power Supply Cord Connection” section.

■ A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations after 1996, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

■ Flexible armored cable or nonmetallic sheathed copper cable

(with ground wire), covered with flexible metallic conduit. All current-carrying wires must be insulated.

■ 10-gauge solid copper wire (do not use aluminum) at least

5 ft. (1.52 m) long.

If using a power supply cord:

Use a UL Listed power supply cord kit marked for use with clothes dryers. The kit should contain:

A UL Listed 30 A power supply cord, rated 120/240 V minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

■ A UL Listed strain relief.

7

ELECTRIC DRYER POWER HOOKUP –

CANADA ONLY

ELECTRICAL REQUIREMENTS

GAS DRYER POWER HOOKUP

ELECTRICAL REQUIREMENTS

It is your responsibility:

■ To contact a qualified electrical installer.

■ To be sure that the electrical connection is adequate and in conformance with Canadian Electrical Code, C22.1 – latest edition and all local codes. A copy of above codes standard may be obtained from: Canadian Standards Association,

178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

■ To supply the required 4-wire, single-phase, 120/240 V, 60 Hz,

AC-only electrical supply on a separate 30 A circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.

■ This dryer is equipped with a UL Listed and/ or CSA International Certified Power Cord intended to be plugged into a standard

14-30R wall receptacle. The cord is

5 ft. (1.52 m) long. Be sure wall receptacle is within reach of dryer’s final location.

If using a replacement power supply cord, it is recommended that you use Power Supply

Cord Replacement Part Number 8529008.

4-wire receptacle

(14-30R)

For further information, please reference service numbers located in the “Assistance or Service” section of your Use and Care

Guide.

■ 120 V, 60 Hz, AC-only, 15 or 20 A fused electrical supply is required. A time-delay fuse or circuit breaker is recommended.

It is also recommended that a separate circuit serving only this dryer be provided.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING:

Improper connection of the equipment- grounding conductor can result in a risk of electric shock. epresentative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with oper outlet

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING:

Improper connection of the equipment- grounding conductor can result in a risk of electric shock. epresentative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with oper outlet

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

8

GAS SUPPLY REQUIREMENTS

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to propane, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column.

Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

GAS TYPE

Natural Gas:

This dryer is equipped for use with natural gas. It is certified by

UL for use with propane gas with appropriate conversion.

■ Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section of your Use and Care Guide.

Option 2 (Alternate Method)

Approved aluminum or copper tubing:

■ Must include 1/8" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer. See illustration below.

■ 1/2" IPS pipe is recommended.

3/8" approved aluminum or copper tubing is acceptable for lengths under 20 ft. (6.1 m) if local codes and gas supplier permit.

If you are using natural gas, do not use copper tubing.

■ Lengths over 20 ft. (6.1 m) should use larger tubing and a different size adapter fitting.

■ If your dryer has been converted to use propane gas, 3/8" propane compatible copper tubing can be used. If the total length of the supply line is more than 20 ft. (6.1 m), use larger pipe.

NOTE:

Pi pe-joint compounds that resist the action of propane gas must be used. Do not use TEFLON

®† tape.

Must include shut-off valve.

In the U.S.A.:

An individual manual shut-off valve must be installed within six (6) ft. (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.

In Canada:

An individual manual shut-off valve must be installed in accordance with the B149.1, Natural Gas and Propane

Installation Code. It is recommended that an individual manual shut-off valve be installed within six (6) ft. (1.8 m) of the dryer. The location should be easy to reach for opening and closing.

Propane Gas Conversion:

IMPORTANT:

Conversion must be made by a qualified technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.

A. 3/8

B. 3/8

C. 1/8

D. 1/2

"

"

"

"

flexible gas connector

pipe to flare adapter fitting

NPT minimum plugged tapping

NPT gas supply line

E. Gas shut-off valve

GAS SUPPLY LINE

Option 1 (Recommended Method)

Flexible stainless steel gas connector:

■ If local codes permit, use a new flexible stainless steel gas connector (Design Certified by the American Gas Association or CSA International) to connect your dryer to the rigid gas supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed, to prevent kinking.

®

TEFLON is a registered trademark of Chemours.

9

GAS SUPPLY CONNECTION REQUIREMENTS

Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.

Use only pipe-joint compound. Do not use TEFLON

® tape.

This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.

BURNER INPUT REQUIREMENTS

Elevations above 2,000 ft. (610 m):

■ When installed above 2,000 ft. (610 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft. (305 m) increase in elevation.

Gas supply pressure testing

■ The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than

1/2 psi.

DRYER GAS PIPE

■ The gas pipe that comes out through the rear of your dryer has a 3/8" male pipe thread.

INSTALL LEVELING LEGS

1.

Prepare dryer for leveling legs

3/8" NPT dryer gas pipe

* NOTE:

If the dryer is mounted on a pedestal, the gas pipe height must be an additional 10" (254 mm) or

15.5" (394 mm) from the floor, depending on the pedestal model. For a garage installation, the gas pipe height must be an additional 18" (460 mm) from the floor.

To avoid damaging floor, use a large flat piece of cardboard from dryer carton; place under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard.

2.

Screw in leveling legs

Diamond marking

Examine leveling legs and locate the diamond marking. Screw legs into leg holes by hand – use a wrench to finish turning legs until diamond marking is no longer visible.

Place a carton corner post from dryer packaging under each of the two dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.

10

MAKE ELECTRICAL CONNECTION –

U.S.A. ONLY

ELECTRICAL CONNECTION

Before you start: disconnect power.

1.

Choose electrical connection type

Power supply cord 4-wire receptacle

(NEMA Type 14-30R).

Go to “Power Supply Cord Connection.”

Power Supply Cord Connection

Power Supply Cord:

Power supply cord 3-wire receptacle

(NEMA Type 10-30R).

Go to “Power Supply Cord Connection.”

4-wire direct connection:

Go to “Direct Wire Connection.”

3-wire direct connection:

Go to “Direct Wire Connection.”

NOTE:

If local codes do not permit connection of a cabinet-ground conductor to neutral wire, go to “Optional

External Ground for 3-Wire Connection.” This connection may be used with either a power supply cord or a direct wire connection.

Power supply cord strain relief

1.

Attach power supply cord strain relief

2.

Remove terminal block cover

Remove the screws from a 3/4" (19 mm) UL Listed strain relief.

Put the tabs of the two clamp sections (C) into the hole below the terminal block opening (B) so that one tab is pointing up (A) and the other is pointing down (D), and hold in place. Tighten strain relief screws just enough to hold the two clamp sections (C) together.

Remove hold-down screw and terminal block cover.

11

2.

Attach power supply cord to strain relief

1.

Prepare to connect neutral ground wire and neutral wire

Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief.

The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.

Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A).

2.

Connect neutral ground wire and neutral wire

If your outlet looks like this:

Power supply cord 4-wire receptacle

(NEMA Type 14-30R):

Go to “4-Wire Power Supply Cord

Connection” on this page.

Power supply cord 3-wire receptacle

(NEMA Type 10-30R):

Go to “3-Wire Power Supply Cord

Connection” on page 13.

4-Wire Power Supply Cord Connection

IMPORTANT:

A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

Connect neutral ground wire (E) and neutral wire (white or center)

(C) of power supply cord under center terminal block screw (B).

Tighten screw.

3.

Connect ground wire

4-wire receptacle

(NEMA type 14-30R)

4 prong plug

12

Spade terminals with upturned ends

Ring terminals

Connect ground wire (F) (green or bare) of power supply cord under green external ground conductor screw (A). Tighten screw.

4.

Connect remaining wires

2.

Connect neutral wire

Connect remaining wires under outer terminal block screws.

Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now go to “Venting Requirements.”

3-Wire Power Supply Cord Connection

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

Connect neutral wire (white or center) (C) of power supply cord under center terminal block screw (B). Tighten screw.

3.

Connect remaining wires

3-wire receptacle

(NEMA type 10-30R)

3 prong plug

Connect remaining wires under outer terminal block screws.

Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now go to “Venting Requirements.”

Spade terminals with upturned ends

Ring terminals

1.

Remove center screw

Remove center terminal block screw (B).

13

Direct Wire Connection

For direct wire installations:

2.

Attach direct wire cable to strain relief

Direct wire strain relief

1.

Attach direct wire strain relief

Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.

If your wiring looks like this:

4-wire direct connection:

Go to “4-Wire Direct Wire Connection” on this page.

3-wire direct connection:

Go to “3-Wire Direct Wire Connection” on page 15.

4-Wire Direct Wire Connection

IMPORTANT:

A 4-wire connection is required for mobile homes and where local codes do not permit 3-wire connections.

1.

Prepare your 4-wire cable for direct connection

Unscrew the removable conduit connector (A) and any screws from a 3/4" (19 mm) UL Listed strain relief. Put the threaded section of the strain relief (C) through the hole below the terminal block opening (B). Reaching inside the terminal block opening, screw the removable conduit connector (A) onto the strain relief threads and tighten securely.

Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed.

Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 1

1

/

2

" (38 mm) from remaining three wires. Strip insulation back 1" (25 mm). Shape ends of wires into hooks.

14

2.

Prepare to connect neutral ground wire and neutral wire

5.

Connect remaining wires

Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A).

Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now go to “Venting Requirements.”

3.

Connect neutral ground wire and neutral wire

3-Wire Direct Wire Connection

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

1.

Prepare your 3-wire cable for direct connection

Connect neutral ground wire (E) and place hooked end (hook facing right) of neutral wire

(white or center wire) (C) of direct wire cable under center screw of terminal block (B). Squeeze hooked ends together and tighten screw.

4.

Connect ground wire

Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed.

Strip 3

1

/

2

" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape wire ends into hooks.

2.

Remove center screw

Connect ground wire (green or bare) (F) of direct wire cable under green external ground conductor screw (A). Tighten screw.

Remove center terminal block screw (B).

15

3.

Connect neutral wire

2.

Connect neutral ground wire and neutral wire

Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B), hook facing right.

Squeeze hooked end together. Tighten screw.

4.

Connect remaining wires

Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center terminal block screw (B). Tighten screw.

3.

Connect remaining wires

Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now go to “Venting Requirements.”

Optional External Ground for 3-Wire

Connection

(Power Supply Cord Shown)

IMPORTANT:

You must verify with a qualified electrician that this grounding method is acceptable before connecting.

Place ends of remaining wires under outer terminal block screws.

Tighten screws.

4.

Connect external ground wire

1.

Prepare to connect neutral ground wire and neutral wire

Install the correct strain relief for your electrical connection method, as shown on page 12 or 14.

Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A).

16

Connect a separate copper ground wire (G) under the green external ground conductor screw (A) to an adequate ground.

Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now go to “Venting

Requirements.”

MAKE GAS CONNECTION

(Gas models only)

WARNING

2.

Plan pipe fitting connection (Option 1)

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to propane, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column.

Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

1.

Connect gas supply to dryer

A. 3/8" flexible gas connector

B. 3/8" dryer gas pipe

C. 3/8" to 3/8" pipe elbow

D. 3/8" pipe-to-flare adapter fitting

A combination of pipe fittings must be used to connect dryer to existing gas line. A recommended connection is shown. Your connection may be different, according to supply line type, size, and location.

3.

Open shut-off valve

A. Flared male fitting

B. Non-flared male fitting

Remove red cap from gas pipe. Using a wrench to tighten, connect gas supply to dryer. Use pipe-joint compound on threads of all non-flared male fittings. If flexible metal tubing is used, be sure there are no kinks.

NOTE:

For propane gas connections, you must use pipe-joint compound resistant to action of propane gas.

Do not use TEFLON

®

tape.

A. Closed valve

B. Open valve

Open shut-off valve in supply line; valve is open when handle is parallel to gas pipe. Then, test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found.

17

VENTING

Venting Requirements

WARNING

Exhaust hoods:

An exhaust hood should cap the vent to keep rodents and insects from entering the home.

■ Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).

■ Do not use an exhaust hood with a magnetic latch.

Recommended Styles:

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING:

To reduce the risk of fire, this dryer MUST BE

EXHAUSTED OUTDOORS.

IMPORTANT:

Observe all governing codes and ordinances.

Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

Louvered Hood

Acceptable Style:

Box Hood

Angled Hood

Elbows:

45° elbows provide better airflow than 90° elbows.

Good

Better

4" (102 mm) heavy metal exhaust vent

■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used.

■ Do not use plastic or metal foil vent.

Rigid metal vent:

■ Recommended for best drying performance and to avoid crushing and kinking.

Flexible metal vent:

(Acceptable only if accessible to clean)

■ Must be fully extended and supported in final dryer location.

■ Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not install in enclosed walls, ceilings, or floors.

■ The total length should not exceed 7¾ ft. (2.4 m).

The length of flexible metal vent used must be included in the overall vent system design as shown in the “Vent System

Charts.”

NOTE:

If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review “Vent System Charts” and, if necessary, modify existing vent system to achieve best drying performance.

Clamps:

■ Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.

18

Plan Vent System

Recommended exhaust installation:

Special provisions for mobile homes:

Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside.

G

A. Dryer

B. Elbow

C. Wall

D. Exhaust hood

E. Clamps

F. Rigid metal or flexible metal vent

G. Vent length necessary to connect elbows

H. Exhaust outlet

WARNING

Fire Hazard

Cover unused exhaust holes with a manufacturer’s exhaust cover kit.

Contact your local dealer.

Failure to follow these instructions can result in death, fire, electrical shock, or serious injury.

Optional exhaust installations:

This dryer can be converted to exhaust out the right side, left side (all models except long vent), or through the bottom.

If you prefer, you may contact your local dealer to have the dryer converted.

A. Standard rear offset exhaust installation

B. Left- or right-side exhaust installation

C. Bottom exhaust installation

Determine vent path:

■ Select route that will provide straightest and most direct path outdoors.

■ Plan installation to use fewest number of elbows and turns.

■ When using elbows or making turns, allow as much room as possible.

Bend vent gradually to avoid kinking.

■ Use as few 90° turns as possible.

Determine vent length and elbows needed for best drying performance:

■ Use the following “Vent System Charts” to determine type of vent material and hood combinations acceptable to use.

NOTE:

Do not use vent runs longer than those specified in

“Vent System Charts.”

Exhaust systems longer than those specified will:

■ Shorten life of dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

The “Vent System Charts” provide venting requirements that will help achieve best drying performance.

Standard Vent System Chart

Number of 90° elbows

2

3

0

1

4

Type of vent

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Angled hoods

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

19

Long Vent System Chart

Number of 90° elbows

0

1

2

3

4

Type of vent

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Angled hoods

160 ft. (48.8 m)

150 ft. (45.7 m)

140 ft. (42.7 m)

130 ft. (39.6 m)

120 ft. (36.6 m)

To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Example: An electric model would be DJ AV – ELE –

XXXXXXX-XXX. A gas model would be DJ AV – NAT – XXXXXXX-

XXX.

NOTE:

For long vent systems, use of box/louvered hoods will improve venting regardless of length.

Install Vent System

1.

Install exhaust hood

2.

Connect vent to exhaust hood

Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint.

Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.

20

CONNECT INLET HOSE

(STEAM MODEL ONLY)

For non-steam models, skip to “Connect Vent.”

The dryer must be connected to the cold water faucet using the new inlet hoses (not supplied). Do not use old hoses.

NOTE:

Replace inlet hoses after 5 years of use to reduce the risk of hose failure. Record hose installation or replacement dates on the hoses for future reference.

Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found.

1.

Turn cold water off, remove hose, and replace rubber washer

3.

Tighten couplings

Using pliers, tighten the couplings with additional 2/3 turn.

NOTE:

Do not overtighten. Damage to the coupling can result.

4.

Attach long hose to “Y” connector and tighten couplings

Turn cold water faucet off and remove washer inlet hose.

Remove old rubber washer from inlet hose and replace with new rubber washer.

2.

Attach short hose and “Y” connector

Attach one of the 5 ft. (1.5 m) inlet hose ends to the “Y” connector. Attach washer cold inlet hose to other side of

“Y” connector. Screw on coupling by hand until it is seated on connector. Using pliers, tighten the couplings an additional 2/3 turn.

NOTE:

Do not overtighten. Damage to the coupling can result.

Attach 2 ft. (0.6 m) inlet hose to cold water faucet. Screw on coupling by hand until it is seated on faucet. Then attach “Y” connector to male end of the 2 ft. (0.6 m) inlet hose. Screw on coupling by hand until it is seated on connector.

21

5.

Attach long hose to dryer fill valve and tighten coupling

CONNECT VENT

1.

Connect vent to exhaust outlet

Remove protective cap from water inlet valve. Attach other end of long hose to fill valve at bottom of dryer back panel. Screw on coupling by hand until it is seated on fill valve connector. Using pliers, tighten the couplings an additional 2/3 turn.

NOTE:

Do not overtighten. Damage to the coupling can result.

6.

Turn on cold water faucet

Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp.

2.

Move dryer to final location

Move dryer to final location, taking care not to crush or kink vent or flexible gas line.

After dryer is in place, remove corner posts and cardboard from under dryer.

Check that the water faucets are turned on.

7.

Check for leaks

Check for leaks around “Y” connector, faucet, and hoses.

22

LEVEL DRYER

1.

Level dryer

Check levelness of dryer from side to side. Repeat from front to back.

NOTE:

The dryer must be level for the moisture sensing system to operate correctly.

Not Level

LEVEL

Not Level

2.

Place level here

Adjust leveling legs

If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once dryer is level, make sure all four legs are snug against the floor and the dryer does not rock.

COMPLETE INSTALLATION CHECKLIST

‰

Check that all parts are now installed. If there is an extra part, go back through steps to see what was skipped.

‰

Check that you have all of your tools.

‰

Dispose of/recycle all packaging materials.

‰

Be sure the water faucets are on.

‰

Check for leaks around “Y” connector, faucet, and hoses.

‰

Check dryer’s final location. Be sure vent is not crushed or kinked.

‰

Check that dryer is level. See “Level Dryer.”

‰

Remove film on console and any tape remaining on dryer.

‰

Wipe dryer drum interior thoroughly with a damp cloth to remove any dust.

‰

Read “Dryer Use” in your Use and Care Guide.

‰

If you live in a hard water area, use of a water softener is recommended to control the buildup of scale through the water system in the dryer. Over time, the buildup of lime scale may clog different parts of the water system, which will reduce product performance. Excessive scale buildup may lead to the need for certain part replacement or repair.

Electric Models:

‰

Plug into a grounded outlet.

Gas Models:

‰

Plug into a grounded outlet.

‰

Check that gas supply is on.

‰

Check for leaks.

‰

Check to be sure that the flexible gas line is not crushed or kinked.

All Models:

‰

Select a Timed Dry heated cycle and start dryer. Do not select

Air Only Temperature setting.

If dryer will not start, check the following:

• Controls are set in a running or On position.

• Start button has been pressed firmly.

• Dryer is plugged into an outlet and/or electrical supply is connected.

• Household fuse is intact and tight, or circuit breaker has not tripped.

• Dryer door is closed.

This dryer automatically runs an installation diagnostic routine at the start of its first cycle.

NOTE:

You may notice an odor when dryer is first heated. This odor is common when heating element is first used. The odor will go away.

23

DOOR REVERSAL (OPTIONAL)

The following instructions are for models with round and square-shaped doors.

Tools needed:

ALL DOORS:

2.

Remove door from dryer

Min. 8" (203 mm) long

TORX

®

, T20

®

, and

T25

®

screwdrivers

#2 Phillips screwdriver

REVERSE DOOR SWING: ROUND-SHAPED DOOR

DOORS WITH ELECTRICAL WIRING:

WARNING

IMPORTANT:

If the protective film has not yet been removed from the dryer, peel the film from the dryer door before proceeding.

Using a T25

®

screwdriver, remove the four screws securing the door hinge to the dryer and lift the door up and out to remove.

Place the door on a soft towel or other non-scratch surface.

3.

Move the door strike

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.

Disconnect wiring from door

Using a Phillips screwdriver, remove middle screw in hinge.

Disconnect wiring. Tuck wiring into opening.

®

TORX, T20, and T25 are registered trademarks of Acument Intellectual Properties, LLC.

24

Using a T25

®

screwdriver, remove the two screws securing the door strike to the door frame of the dryer. Rotate the strike 180° and attach to the opposite side of dryer door frame with the two screws removed earlier, as shown.

4.

Remove inner door from outer door

6.

Remove latch

Thin section

Latch

Thick section

Top of door

Position the door with the inside of the door facing up. Using a Phillips screwdriver, remove the 10 screws securing the inner door to the outer door.

5.

Remove hinge

Flip and rotate the inner door 180° so that the thin section is at the top and the thick section is at the bottom. Using a T25

® screwdriver, remove the four screws securing the latch plate in place.

7.

Reinstall latch on opposite side

Hinge

Using a T20

®

screwdriver, remove the six screws holding the hinge assembly in place.

Using a T25

®

screwdriver, reinstall the latch plate on the opposite side from which it was removed with the four screws removed earlier.

25

8.

Reinstall hinge assembly on opposite side

10.

Reposition rotating assembly and tubing

Flip over the inner door to the left. Using a T20 was removed.

® screwdriver, reinstall the hinge assembly on the opposite side from which it

DOORS WITH ELECTRICAL WIRING:

9.

Remove rotating assembly

Reposition rotating assembly and tubing 180° to opposite side of the door.

11.

Rotate assembly bottom and fasten in place

Press tubing into indents.

Lift off inner door assembly. Using a Phillips screwdriver, remove the two screws securing the rotating assembly to the door.

Rotate bottom of assembly 180° towards you and secure assembly with the two screws removed earlier, using a Phillips screwdriver. Press tubing into indents.

IMPORTANT:

Make sure to swing hinge down in front of rotating assembly (see Step 12).

26

ALL DOORS:

12.

Reinstall inner door assembly

DOORS WITH ELECTRICAL WIRING:

14.

Reconnect wiring

Swing down

Bottom of door

Position the door with the inside of the door facing up. Using a Phillips screwdriver, reinstall the 10 screws removed earlier, securing the inner door to the outer door.

13.

Reinstall door on dryer

Plug in wire. Using a Phillips screwdriver, secure the rotating assembly to the hinge with the screw removed earlier.

Doors with electrical wiring:

Pull the wire through the front panel opening before reinstalling the door.

Insert the tabs on the hinge into the mounting slot and slide down to engage the top tab. Secure in place with the four T25

®

screws removed earlier.

27

REVERSE DOOR SWING: SQUARE-SHAPED DOOR

1.

Remove door from dryer

3.

Remove inner door from outer door

Release tab

Release tab

Using a T25

®

screwdriver, remove the four screws securing the door hinge to the dryer and lift up and out to remove the door. Place the door on a soft towel or other non-scratch surface. Retain or set aside the four screws.

Position the door with the inside of the door facing up. Using a Phillips screwdriver, remove the 13 screws securing the inner door to the outer door. Lift off the inner door and set aside.

NOTE:

There is a small release tab on each side of the door. If the inner and outer door do not separate easily, slide a credit card, putty knife, or similar flat object between the inner and outer doors at the locations shown to release the tab.

2.

Move the door strike

4.

Remove hinge and latch from inner door

Hinge

Using a T25 ® screwdriver, remove the two screws securing the door strike to the door frame of the dryer. Remove the four screws above and below the door strike and set aside for later use. Rotate the strike 180° and attach to the opposite side of dryer door frame, as shown.

Latch

Using a T25

®

screwdriver, remove the three screws securing the latch plate and the five screws holding the hinge assembly in place.

28

5.

Reinstall hinge and latch on opposite sides

Latch

7.

Reattach door to dryer

Hinge

Using a T25

®

screwdriver, reinstall the latch plate and hinge assembly on the opposite sides from which they were removed.

Using a T25

®

screwdriver, reinstall the four screws securing the door hinge to the dryer.

6.

Reattach inner door to outer door

Position the inner door on the outer door assembly. Using a

Phillips screwdriver, secure with the 13 screws removed earlier.

29

W11183136B

W11183139B-SP

06/19

® / TM ©2019 All rights reserved. Used under license in Canada.