Stanley U-INSTALL Owner's Manual
PDF
Dokument
Reklama
Reklama
HON'IEAUTOTNAflON
IJ.INSTALL@
GARAGE
D O O RO P E N E R S
O W N E R ' SM A N U A L
...
FORUSEON MOSTTVPESOF GARAGEDOORS
DO NOTTHROWTHISMANUALAWAY.
Keep in a safe locationfor future reference.
Do not connectto poweruntil instructedto do so.
o
Do not run door openeruntil completelyinstalled.
a
Dooropenerwill not operateuntil beamsensor
is installedand properlyaligned.
. For your protection,wear safetyglasses.
Readand follow ALL instructionscarefully.
o21 .O259E
Dear Homeowner,
Pleasetake a moment to read the following IMPORTANT
installation of your new garagedoor opener.
INSTALLATION
INSTRUCTIONS prior to beginning assembly and
THROUGHOUT
THIS
THISCAUTIONSYMBOLAPPEARSPERIODICALLY
IMPORTANT
SAFETYINSTRUCTIONS.
MANUAL.IT WILLIDENTIFY
A. Br
suRE To READ AND FoLLow ALL rNsrALLATtoN
TNSTRUCnONS.
B. lnsmll
rHE GARAGE DooR opENER oNLY oN A PRoPERLY
BALANCED AND LUBRICATEDGARAGE DOOR. AN ilPROP.
ERLY BALANCEDDOOR COULD CAUSE SEVEREINJURY.
L u e n t c R r e y o u R D o o R B Y A P P L Y T N GA L I c H T o l L o R
S I L I C O N EL U B R I C A N TT O T H E D O O R H I N G E S ,M O U N T I N G
, OUN OOON
H A R D W A R EA N D T H E R O L L E RB E A R I N G S Y
S H O U L DM O V E F R E E L YB Y H A N D W I T H O U TS T I C K I N GO R
BINDING.DO ruOTAPPLYOIL OR GREASETO THE ROLLER
T R A C K S . C O I ' I O U C TD O O R B A L A N C E T E S T B E F O R E
INSTALLATION,
BEGINNING
DOORBALANCE TEST
Raise your door to its mid-point and release it, The door
should remain in this position without moving up or down.
If the door is moved to the 314open position and released,it
should remain in place or move slowly to the full open
position.
If the door is moved to the 3/4 close position and released,it
should remain in place or move slowly to the full close
position.
If the door fails any of these three door tests, the springs may
be out of adjustment. Ilave a qualified service person make
repairs to cables, spring assemblies and ot[er hardware
before installing the opener. Some parts are under
EXTREME tension at times and can cause serious injury if
improperly handled.
C, Reuove ALL RopEs AND REMovEoR MAKEINoPERATIVE
TO THE GARAGEDOORBEFORE
ALL LOCKSCONNECTED
OF DOOB
ENGAGEMENT
ACCIOENTRT
OPENER,
INSTALLING
AND
TO DOOROR OPENER
IN DAMAGE
LOCKSMAYRESULT
INJURY.
PERSONAL
POSSIBLE
E , Mouw
rHE RED EUERGENcv RELEASE KNoB 6 FEET
ABOVE THE FLOOR. IT SNOUIO BE REACHABLEBY ADULTS
IN THE HOUSEHOLD
TO ALLOWMANUALUSE OF THE GARAGE
DOORIN AN EMERGENCY.
F. Do tor coNNEcropENERTo powEn souncE UNTIL
INSTRUCTED
TO DO SO. EXTTruSIONCORDSSHOULDNOT BE
USED.THE OPENERMUSTBE PLUGGEDINTOA PROPERLY120 VOIT THREE-PRONG
OUTLET,
GROUNDED
G , LocnrerHEpusHBurroN
courRol BurroNwtrHtNslcHT
OF THE DOORANDAT A MINIIIUMHEIGTITOF 5 FEETABOVE
THEFLOORSO SMALLCHILDRENCANNOTREACHtI. MOUNT
PARTSOFTHEDOOR.
rT AWAYFROMALL MOVING
WARNING
H . Be suRero rNsrALL
rHE ENTRAPMENT
Reno rte
LABEL NExrro rHE coNTRoLBUTToN.
CONTROLADJUSTMENTWARNINGLABEL ott
THEREAROFTHEOPENER
ANDALSOTHEEMERGENCY
oN
D THE
R E L E A S E T A G , w H r c Ht s T N S T A L L E
RELEASE
CORDOFTHETRAVELER.
EMERGENCY
L A r r s n T N S T A L L I ND
Go o R o p E N E R ,T H E D o o R M U s r
WHENIT COMESIN COiITACTWITII A 1.1/2 II'ICTI
REVERSE
HrcHoBJECT(On l2X4 BOARDLA|DFLATONTHEFLOOR).
MEcHANtsM
orreru (oruce
Cnecr rHE sAFEw REVERSTNG
wtrH
tr REVERSES
ro ENSURE
A MoNTHrs REcoMMENoeo)
A MINIMUM
AMoUNToF FoRcE. Txs uusr BE RETESTED
lS MADETO THE DOORARttl'
ANY Tlf,E AN ADJUSTMENT
FORCEANUSTIiENTS,OR CLOSEDPOSmONAIITUSTilENT.
DRtvEoR srRUcruRAL
J , lp oRtuReero ANy MEcHANtcAL
DISCONTINUE USE
OF UNITIS OBSERVED
COMPONENT
G
A R A G Eo o o R / o o o R
A
N
A
U
T
H
o
R
t
z
E
D
A N Dc o N T A c r
D
E
A
L
E
R
o
R
T
H
E
C
o
l
tsutrlen SeRvtce
opENER
NEVER
OPERATE THE
rMMEDrArELy.
DrpRRrlerur
OPENERIF THE SYSTEMIS NOT FUNCTIONING
PROPERLYOR IF IT WILL NOT REVERSEOFF
OF A 1.1/2INCHHIGHOBJECT.
D, lr posslElE, tNsrALL DooR oPENER7 FEEToR itoRE
WITHMOST
ABOVETHEFLOOR.THISIUNYNOTBE POSSIBLE
OVER6 TOOT
DOORS,
IruTNISCASEINDIVIDUALS
ONE.PIECE
WHILEIN
OBSTACLE
BE ALERTTO THISPOTENTIAL
SHOULD
THEGARAGE.
Page 2
02c.2
CONTROLS
EMERGENCYRELEASE
Your new garage door opener offers momentary control. To
operate the door simply press either the hand held transmitter
button or the wall mounted pushbutton for one to two seconds
and the door will automatically open or close. The opener can
be stopped during any portion of the opening or closing cycle
by pressing either of the buttons. The next time the button is
pressed, the opener will re-start the door in motion in the
opposite direction.
Your door opener is equipped with an emergency release
device. In the event of a power failure, pull the knob on the
pull cord down and slightly to the back (away from door)
allowing the disconnect to latch. This will allow you to manually open or close the door. When power has been restored,
gently pull the disconnect cord, releasing the traveler detent,
then press either the transmitter or pushbutton. The opener
will automatically reconnect.
OBSTRUGTION
SENSING
SAFE.T.MONITORTM
When properly adjusted,the door will automatically reverseif
it sensesan obstructionduring the closing cycle. This system
will also stop the door if it hits an obstaclewhen opening.
A dynamic obstruction detection device that continuously
monitors the amount of force required to move the garage
door, and automatically adjusts the obstruction detection level
in addition to the homeowner adjustable force levels. This
SAFETY SYSTEM adds the additional level of protection
indicating our commitment to safe garagedoor operation.
SAFE.T.CYCLETM
This electronic system will reverse the door in 30 secondsor
less if the door is unable to travel to the full closed position.
This feature provides automatic reversing should other systems fail to operateand the door does not fully close.
SAFE.T.SIGNALTM
Lights will flash whenever Safety Reverse or Safe-T-Cycle
hasbeenactivated.
CONTROLCONNECTIONS
All opener models are provided with screw terminals for the
attachment of a wall mounted pushbutton or four-function
wall console. The console includes a pushbutton,worklight
switch, vacation switch, and pedestrianlight. Some models
are provided with a pushbuttononly, but ALL MODELS can
be connected to the four-function wall console which is sold
separately.
FORCEADJUSTMENTS
Independent OPEN and CLOSE dials allow you to select the
minimum required opening and closing force.
Voltage Required:
120 Volts a.c.
60 cycle
Single Phase
A grounded,three (3) hole electrical outlet is required.
Motor Specs:
PermanentSplit Capacitor -Internal
Automatic Over load Reset
Current Required:
7 AMPS
Overload Protection:
The motor is equipped with an automatic thermal over load device. Should the motor become
over heated,the over load device will render the opener inoperative. Simply wait approximately 5 to 10 minutes for the
motor to cool.
03c.1
Opener Length:
Minimum Head
Room Required:
10Feet-8Inches
From end of tube assemblyto
rear of opener power unit.
2 Inches (Tracked Doors)
6 Inches(TracklessDoors)
Average Door Speed:
6 Inchesper second
Maximum Door Size:
L/4H}.:
16 Ft. Wide / 7 Ft. High
1 / 3H . P .o r I / 2 H P . :
18 Ft. Wide l7 ll2Ft.High
Page3
This garage door opener is intended
WARNING:
for use on one of the types of doors shown below
ONLY. It is UNSAFE to attempt installation on
any other type of door or moving mechanism.
ONE.PIECE
TRACKEDDOORS
Use the illustrations on this page to determine the major components of your garugedoor. It is suggestedthat before you
begin with assembly,you review the mounting procedure outlined on page 11. This will help you plan out, aheadof time, a
means of securing the power unit.
DOORS
TRACKLESS.TYPE
SECTIONAL
TRACKEDDOORS
I
I
I
I
I
I
I
I
I
,i:::',x:iJlh
'T:5ff:;l',!'
I
ourLrNE.
I- I aoxeo
I I I I I I
@
I
DOOR HEADER - The wood or metalbeampositioned
horizontallyacrossthetop ofthe garagedoorway.
ROLLERS - Attached to the door and follow
@ DOOR
inside
DOOR SPRING- Springsusedto balancethe door. 81
- Torsionspring,82 - Extensionspring.
@ HIGH-RISE - The highest point the top of the door
DOOR TRACKS - Metal guidesto allow the door to
travela straightpath. Not usedon tracklessdoors.
@ HEAD ROOM - Area between high rise of door or the
the door tracks. Not used on tracklessdoors.
reacheswhen opening.
door spring and the bottom ofrafters or finished ceilings.
Do not attempt assembly with less than 2 inches of head
room.
To become more familiar with your new GARAGE DOOR OPENER, please take time to study the following illustration of the
completed unit and terminology. It will help you in the assemblyand installation.
Assembled ldlerTube
TubeSections Assembly
Power
Cord
Header
Bracket
\
Control
Connections
/tiltguuvtto\
BarLink
Obstruction
_ \
SensorPlug
CodeSwitch..-i
Open/Close
ForceAdjustments
.f'
L Link
l 1
Link
powerUnit
V
-./
./
Adjustments RnLnna EmergencyRelease
Open/ ClosePosition
DoorBracket
Page4
I
- -o*ll
I
Bar
Link
I
Y
_y*l
J
04D.1
Carefully inspect your new garagedoor opener for any possible damage and,ior shortage of parts. Separateall parts, fasteners and
accessoriesas called out below. Do not attempt installation if parts are damagedor missing.
Oo r'rornur,roperrreR
uNTrLTNSTRUcTED,
MAycHANGE
ANDcAUsEFAULTv
Srourruce oF opERATroN
opERATroN!!
PowerUnit
Lamphouse
SuppliedWith SomeModels
SingleButton
Transmitter
Two Button
SignalBlockrM
Transmitter
.,#
(-\
-YZZ)7
NZ
Pushbuttonand Screws
(Type providedmay vary)
/'
4 Tube Sections
2 - CarriageBolts
Plug
4 - Lag Screws
@rofl@'
\'lP
-u
9 - Hex Bolts
B' HeaderBracket
(Supplied
with
1 - ShoulderBolt
2" ClevisPin
rffiry
1-112"
ClevisPin
MountingAngle
%
L Link
--)
\=-
N\
\
obstructronSensor,Brackets,Wire and Screws
5"and1/2"Socket
or Pen
n Pencil
<.F-m)
n StepLadder
,W
n Pieceof 2" x 4"
05D.3
I
Page5
ldlerTube
AssembleTube Sections
1-112"
ClevisPin
AlignHoleson the Side
to Make Assembly
Stronger
FlG. 2
PlugButton
To protect the power unit during assembly and installation,
use one of the cardboard panels packed with the unit. Locate
the radio transmitter inside the packing material and set it
asidein a safeplace.
B . Insert plug button into end of the tube, (make sure it is
A. Assemblethe 5 tube sectionswith the holes alisned on the
side as shown in Fig. 1.
C . Slide the traveler onto the tube assemblymaking sure the
arrow on the traveler marked ( |D|o6;>)points towards the
idler assembly.
M A K EC E R T A I N
T H A TT H ET U B ES E C T I O N A
SRE
FULLYSEATED
There may be a small spacebetween tube sections,hou,ever
t h e " E n d T o E n d " a s s e m b l e dl e n g t h m u s t b e 1 1 8 - 1 i 4 "( o r
less). (You may needto gently tap them together.)
fully seated).See Fig. 2. Attach the pulley to the other end
of the tube using the one and one half inch (l l/2") long
clevispin and a lock clip. SeeFig. 24.
D Insert the end of the tube assembly that has the plug button, into the tube support on top of the power unit. See
Fis. 3.
FIG.3
TubeSupport
PlugButtonEnd of
TubeAssembly
ldlerAssembly
Page 6
06E.2
FIG.4
39" to 41" for
Tracked-TypeDoors
ldlerAssembly
I I I -
50"to 52"for
Trackless-Type
Doors
I I I I
A. Position the traveler 39" to 41" from the front edge of the
tube support on the power unit for Tracked-Type Doors.
Position the traveler 50" to 52" from the front edge of the
tube support on the power unit for Trackless-Type
Doors. SeeFig. 4.
B. Using a masterlink assembly,securethe loose end of the
chain to the traveler carrier, as shown in Figs. 5 and 6.
Make certain that the master link retaining clip is posi.
tioned on top.
C. Carefully unroll the chain towards the power unit. Loop
chain around drive sprocket on top of power unit and continue to unroll chain until you get to the end. Check to BE
SURE the traveler is the correct distance from the tube
support edge. If not, reloop chain around drive sprocket.
SeeFig. 7.
MASTERLINK
ASSEMBLY
STOP! Rrno Srep A orupnce I aerone pRocEEDtNG.
IT IS VERY IMPORTANT THAT THE TRAVELER !S
P O S I T I O N E DC O R R E C T L Y .
39" To 41" FoRTnncreo-TvpE DooRS
Doons
50" ro 52" FoRTnncruess-Tvpe
FIG.7
TubeSupport
07D.3
I
PageT
A. Secureone end of the cable to the chain with a master link
assembly. Make certain that the master link retaining
clip is positioned on top. See Fig. 8. Feed loose end of
cable through the idler assembly. Continue pulling cable
through idler assembly until loose end can be attached to
traveler carrier. SeeFis. 8A.
B. Secure the cable to the traveler with the master link
assembly. Make certain that the master link retaining
clip is positioned on top.
TRAVELERDISTANCEFROM TUBE
SUPPORT:
39" to 41u - Tracked-TypeDoors
50" to 52" - Trackless-TypeDoors
FIG.8A
IMPORTANT: MnrE cERrAtNTHETRAVELER
ts postnoNED
THE CORRECT
DISTANCEFROMTHE ENDOF THE TUBESUP.
P O R T ,l F N O T ,R E M O V E
M A S T E RL | N K A N D G O B A C KT O
PAGE7.
NOTE: Before pioceeding, please note that when adjusting
the chain and cable, there should be a slight chain sag, about
l/2 inch below the mid-point of the tube.
C. Adjust the chain/cable tension by tightening the adjustment screw located at the rear of the tube support using a
7/16" socket wrench or screwdriver. (Clockwise rotation
w i l l t i g h t e n t h e c h a i n / c a b l e ,c o u n t e r c l o c k w i s ew i l l
loosen). See Fig. 9. Be careful not to bend the screw when
adjusting.
FIG.9
D. Install the chain guard over the drive sprocket by pressing
down until its tabs snap into frame.
NOTE: The instruction tag describes how to manually disconnect the opener from the door. Pleaseread it now because
further on in the instructions you will be instructed to "pull
the emergencyreleasecord."
Page 8
Adiustment
Screw
08c.1
IMPORTANT! lr rs cRtlcAL rHAr you tDENlFywHArrypE
OF DOORYOU HAVEAS IT WILL MAKE A DIFFERENCE
IN THE
wAy youR opENERls INSTALLED,
seE pnce 4.
A. Locate the centerline of the door. Mark the centerline of
the door on the header above the door and the top of the
door, SeeFig. 10.
FrG.10
F - r r r T SPECIAL
INSTRUCTIONS!T
DoorsOnly
I Trackless-Type
of Door
-T 6" AboveHiqh-Rise
-
T
I
I
I
T
I
Add six (6) inches to the distance measuredfor high-rise
for Trackless-Type Doors.
Using this new figure, measureup from floor to bouom of
bracket and mark that point on the door header. Laate the
header bracket atthal point and directly on rhe centerline
mark. (The header bracket may be mounted higher,
but do not mount any lower.) SeeFig. 11.
I M P O R T A N T : S o u e M o D E L sA R E s u p p L t E ow m r r r g '
HEADER
BRAcKET
FoR usE oN I' HtcHDooRs.lr voun rco€L
ls SUPPL|ED
W|THTH|S BRACKET,PLEASELOCATE1T xOW
ALoNGwtrH THE8' nEADeRBRACKET
MouNnNGFrsrBtcnot{s
WHICHARE PACKAGED
SEPARATELY.
FOLLOWTHESET|STRIJC.
TloNs,THENCONTTNUE
ONTO PAGE10 rrurxe rAfllrAt_NOTE: A nail may be used to temporarily hold the header
bracket in place.
D. Holding the header bracket securely in position, mart the
two holes of the header bracket on the door header. See
Fig.12.
8'l-leaderBrdet
(Sugftd *fr
F t G .1 2
usingthemarksasa guide.SeeFig. 13.
B . Slowly raise the door. When it reachesits high.rise point
F. Secure the header bracket to the door header wift two lag
screws.Make sure bracket is tightly secured
(highest distance off the ground when door is opening),
place a support (prop) under the door to hold it at that pos!
tion. Measure the distancefrom the floor to the top edge of
door. SeeFig. 11. Remove support and lower door.
C. Add two (2) inches to the distance measuredfor hieh-rise
for Tracked-TypeDoors.
Sectional
TrackedDoor FlG. 11
NOTE: In some types of garages,there may be a geel chann€l
acrossthe door header.If this channelis there,drill g16. boles
in the channeT,and I/4" holes in the door header.
I I I I I I
TNSTRUCTTONS!
I SPECTAL
Trackless-Type
DoorsOnly
a
I
I MarkHere
I
I
I
I
I
I
I
High Rise
I I
09F.1
SorellorB)
I I
I rrc.rs
1/4'Drled lG
t :
I
I
-J
Page 9
A . Place the power unit on the floor and raise the idler assembly up to the headerbracket. SeeFig. 14.
F r G1. 4
ldlerAssembly
B . Using the 2" clevis pin and a lock clip, secure the idler
assemblyto the headerbracket.SeeFig. 15.
NOTE: The header bracket is designedwith an additional
positioning hole if height adjustment is necessary.It can also
be mounted upside down for further adjustment.
FlG. 15
C . Carefully raise the power unit and set it on a ladder or
other suitable prop. See Fig. 16. Unit should be high
enough to clear door when fully opened'
LockClip
Brackel
Header
Fo<
D. Pull the emergencyreleasecord down and slide the traveler assemblytoward the Powerunit.
Traveler
Assembly
F t G .1 7
ONE PIECEAND SECTIONALTRACKED
DOORSONLY
E. Raisethe door to the full open position and place a2" x 4"
board (on edge) between the tube and the door. The 2" x
4" will ensure that the tube assembly will have enough
clearance when the door is opening. Set the operator so
that the tube rests on the 2" x 4" directly in line with the
centerofthe door. SeeFig. 17.
Page10
108
F I G ,1 8
TRACKED.TYPE
DOORMOUNTING
I
I
I
I
I
I
I
I
r
l
li:?,Hl11
\[
_
J€<
l=^
r a-^'
v
I r raveler
.
be (at
tubesuppon)
support) a\
1artuoe
Ll
be approximately P
MERTHANthetop
garagedoorwhen
openeo.
openeo.
-
r
FrG.20
2" Above
High-Rise
of Door
Dooras it Opens
--r
TRACKLESS-TYPE
DOORMOUNTING
f Lowerinsthe, \
]oo*urrn,. \
ll
I-
/
I I I I I I I I I I I I I I
I
I F t c .1 9
II
Positionof Top of /
Doorin
OpenPosition
Traveler
PowerUnit
r
r
r
r
r
r
r
r
r
r
-
r
4
El
-l-
Jv
-
-
r
I
:
l
LF--Ll--Doorin
OPen
Position
r
-;"5'=':-:
J
GARAGEWITH OPEN BEAMS
GARAGEWITH FINISHEDCEILING
SEGURINGPOWERHEAD
General Information: Mounting instructionsfor the power
unit must, of necessity,be somewhatgeneralin nature due to
the many different ceiling designs found in various residential
and geographicalareas. Custom-designedgaragesmay have a
finished ceiling of gypsum, sheetboard, or finished tongue and
groove style lumber. In other instances,unfinished ceiling types
will have exposedoverheadwood beams,2" x 4", or 2" x 6"
rafters,joists, etc. Due to theseconstructionvariances,every
power unit installation could be slightly different with different
circumstancesarising for each specific mounting application.
For finishedceilings,a sectionof 1" x 6" board can be secured
to spanthe distancebetweenceiling rafters. The power unit can
then be mounted directly to the board using the mounting angle
and straps.Ifnecessary,lag screws,longerthan thosefurnished
with the opener,or expansionbolts can also be used. Basic carpentry procedures,coupled with a little pre-planning,should be
all that is required to mount the power unit. If needed,a local
carpentercan be contactedto provide whatever assistanceis
required.
11C.1
The main concern in mounting the power unit is
that the installation be securelymounted for operational strength, rigidity and safety. Mounting
straps can be easily bent and cut to conform to ryhatever
conliguration that may be required. SeeFigs 18 and 19.
A. Mount the power unit to an overheadbeam or ceiling. See
Fig.20 for typical mountingsuggestions.For mounting,use
lag screws,hex headbolts, hex nuts and lockwashers.(Lag
screwsare for use in overheadwood beamsor ceilings; hex
headbolts and nuts are for mounting strapsand angle.) The
adjustablewrench and ll2" socket wrench are required.
Additional 2 x 4's may be neededfor proper installation.
B. Once power head is securely mounted, remove all supports
and ladders. Operatethe door manually severaltimes to
ensurethat the door travels freely and does not contact any
part of the tubes. Top pdge of door should clear the tube
sectionsby at leastone inch.
Do not allow door to hit the traveler.
Page 11
A. Assemble the L link to the bar link, as shown in Fig. 21
for tracked-type doors and Fig. 22 for trackless-type
doors. Use two (2) hex bolts, lockwashersand hex nuts to
securethe links.
B . Attach the door bracket to the L link and bar link assembly. Use the shoulder bolt, lockwasher and hex nut. Make
sure it is assembledas shown.
C . Attach the L link and bar link assembly to the traveler.
Securethe assemblyto the traveler by inserting the 1 inch
long clevis pin through the traveler and the assembly,
Insert a lock clip through the small hole in the clevis pin.
Assemble as shown in Fig. 2l for tracked-type doors or
Fig,22 for trackless-type doors.
D. Pull the emergency releasecord down and cock it
(towards the door). Move traveler assembly toward the
door.
I I I I I
F - I I I I
I FtG.22
I ronrRAcKLFss- ,r
iv;t'ffidis-d,i'"
i
f M,ff
l'lULz // u I
I Lo.k*".h",s
I
| "no*N'
I
r \6:%- Z2-,,,n^
1
rt
q
I
r \ - w
\
I
l
DooRMouNrtNG
TRAcKED-TvpE
^ i
, * j . , , , fif i
I
I
FlG. 21
I
\
HexBorts l
a\-
\-ql
<
'
I
L - r r r r r r - r - J
DOORREINFORCEMENT
ro
DAMAGE
IMPORTANTNOTICE: To pnEveNrposstBLE
LockClip
V
STEELAND FIBERGLASSDOORS
GARAGEDOORS,LTGHTWETGHT
MUST BE RernroncEB
D E F o R rEH E D o o RB R A c K EtTs
KITS ARE AVAILABLEFROM
INSTALLED.DOOR REINTORCEMENT
SOME DOOR MANUFACTURERS.ALWAYS SUPPORTTHE INSIDE
OF THE DOOR BOTH VERTICALLYAND HORIZONTALLYWITH A
2x4 aonno, oHANNEL,oR ANGLE rRoN. THE vERTtcAL BRAoE
1" ClevisPin
M U S T C O V E RA T L E A S T T H E T O P P A N E L O F A S E C T I O N A L
DOOR, AND THE HORIZONTALBRACE MUST BE AT LEAST SIX
(6) reer LoNG.SEEFrc. 23.
F A I L U R ET O P R O P E R L YB R A C E Y O U R D O O R
P R I O RT O T H E I N S T A L L A T I O NO F O P E N E RM A Y
RESULT IN SEVERE DOOR DAMAGE. THE ADDI.
TION OF THESE BRACES MAY AFFECTTHE BAL.
ANCE OF THE DOOR. AFTER INSTALLATION,
C H E C K F O R P R O P E RM A N U A L O P E R A T I O NA N D
HAVETHE DOORREBALANCEDIF NECESSARY.
FtG.23
lnsideof
Top Panel
ShoulderBolt
(mustbe
positionedas
shown)
Horizontal
Support
AnglesNot
Supplied
Door Bracket ----)
VerticalSupporlAngle- Not Supplied
Page 12
12C.1
E. Position the door bracket near top of door, as close as possible to the center of the top door roller and mark the two
door bracket holes on the door. On sectional doors, the
door rollers should be 3" to 6" from the top ofthe door. If
they are not, simply position the door bracket 3" to 6"
below the top of the door. SeeFig.24.
3"-6"
Sectional
Doors
Markand Drill
5/16"Holes
- r
r
r r r r - r
SPECIALINSTRUCTIONS!
-
- l
I
TRACKLESS
DOORSONLY
I
I
I
I
I
I
I
I
I
I
I
I
I
I
WOODSECTIONAL
FtG.27
I
DOORS
I
I
I
I
I
I
I WOOD
METALDOORS I
I DOORS
I
I
I
I
I
il\*
A
.
I
I
wRoNG
I
I
F. Move the traveler back and drill two (2) 5/16" holes
throush the door at the marked hole location.
FtG.24
l r
Position the door bracket on the top edge of the door,
directly on the centerline of the door. Use a pen or pencil
to mark the hole locations on the door. Drill (2) 5116
holes through the door at the marked hole locations. See
Fig.26.
NOTE:Bar link should be
adjusted to 45oas shown.
G. Move traveler assembly toward the door and attach door
bracket to door. Use hex bolts or cariage bolts to securely fasten bracket to door. SeeFig. 25.
FtG.25
ONEPIECEANDSTEEL
SECTIONAL
DOORS
Use hex bolts or carriage bolts to securely fasten
bracketto door, SeeFig 27.
DoorBracket
//
MAKESUREdoor
linkageis straight
whendoor bracketis
securedto door,
H. Manually open the door
to assureunobstructed
movement.
NOTE:
When door is fully open
the traveler should be at
least 8" away from the
power unit. If not, shorten the door linkase as
required.
l:r
I
Carriage
Bolt,
Lockwasher
andNut
RIGHT
138.1
Page 13
FoR
IMPORTANT: THe oooR opENERpRovrDES
p o s r l v E c L o s r N Go F T H E D o o R . A t - l e x t s r t r u c
DooRLocKs MUSTBEMADEtNopERnrtve.lr exlst-
repositioned or the complete lock assembly may be removed.
Because of the many styles of door locks, the illustrations
show only two of the more common types.
I N G D O O R L O C K S A R E L O C K E DW H I L E T R Y I N GT O U S E T H E
OPENER,DAMAGETO OPENERAND DOORCOULDRESULT.
IMPORTANT:lr rs rruponrerur
THAT ALL ROPES
A N D C O R D S ,T H A T C O U L DC A U S EE N T A N G I - E M E N T ,
BE REMOVED
FROMTHE DOOR.
Pin or screw the existing lock mechanism in the "open"
(unlocked) position. If necessary,the catch latches may be
FrG.29
*'t
_-- Remove
Lock Plates Both Ends ol
Doors
Pin or Screw
in Unlocked
Position
Your garage door opener is supplied with an infrared beam
sensorthat sends an invisible beam of light from the sending
unit to the receiving unit across the pathway of the door.
Please read and follow these instructions carefully.
IMPORTANT: THe DooR
O P E N E RW I L L N O T O P E R A T E
U N T I L T H E B E A M S E N S O RI S
C O N N E C T E DT O T H E P O W E RU N I T A N D
P R O P E R L YA L I G N E D .T H et n v t s t a reee a uo r
L I G H TM U S TN O T B E O B S T R U C T E DO, T H E R W I S ET,H E
CONSTANT
D O O R C A N B E C L O S E DB Y M A I N T A I N I N G
ONLY.
PUSHBUTTON
WALL-MOUNTED
PBESSURE
ON THE
T
o
c
l
o
s
E
THE
B
E
u
s
E
D
c
A
N
N
o
r
THe rnnrusutrrER
EITHER
THE
uslNc
BE
opENED
ooon. Tue DooR cAN.
W
A
L
L
M
O
U
N
TED
O
R
H A N D - H E L DT R A N S M I T T E R
I
S
N
O
T
A
L
I
G
N
E
D
O
R
T
H
E
B
E
A
M
PUSHBUTTOE
NV E NI F
P
U
L
L
E
M
E
R
G
E
N
CY
U
N
I
T
.
TO THE POWER
CONNECTED
FROM
OPENER,
DOOR
RELEASECORDTO DISCONNECT
T H E N M A N U A L L YC L O S E G A R A G E D O O R B E F O H E
A. Begin by attaching the sending and receiving units to the
mounting brackets using the four thumb screws provided.
The thumb screws go through the bracket and thread into
the two holes on the bottom of the units. Do not tishten at
this time. SeeFigure 30.
FrG.30
RedAlignment
Light
35 Feet of Wrre
Receiving
Unit
*-Sending Unit
2 Thumb
Screws
CONTINUING.
Before beginning beam sensor mounting, identify
which side of the garage door opening (if any) the sun
is "likely" to shine into. Since sunlight may cause
undesirable operation, you should plan to mount the
small sending unit (not the receiving unit) on the side
of the door opening exposed to the sun.
Page14
Mounting
Bracket
2 Wood
Screwsfor
Mounting
2 Thumb
Screws
148.3
E. If wires must be lengthened,use wire nuts or a suitable
connector. One wire has a white stripe. Be sure to connect
white wire to white wire.
B . Select a mounting position 2 to 4 inches above the floor. If
possible the sending and receiving units should be
mounted at least 12 inches inside the door opening to
minimize any interferenceby the sun. SeeFigure 31'
F. Mount the sending unit the same way you mounted the
receiving unit with the wood screws provided, but
approximately one (1) inch higher. Make sure the sending
and receiving units point toward each other and are not
obstructedby the door tracks or other objects.
C . Using the wood screws provided, attach the receiving unit
to the wall. In some installationsit may be necessaryto
attach wooden spacersto the wall to insure that the beam
will clear the door tracks. Expansion bolts (not supplied)
may be required to attach brackets to walls constructed of
materials other than wood or gypsum.
Carefully loop and secur€ any additional wire in a safe
location. Do not staple through wire.
G . Uncoil the remaining loop of wire with the small 2-pin
connector attachedto one end. Route the wire up the
garagewall acrossthe ceiling and down to the back of the
power unit. Temporarily tack the wires in place using the
staplesprovided.
The beam must be mounted as close to the door
track or inside edge ol' thc door as possible to
of'f'ermaximum entrapment protection.
D. Do not tighten the mounting screws at this time. Carefully
uncoil the wire that is connectedto the small sending unit.
Run the wires up the wall across the top of the door
opening and down the other side of the wall. Temporarily
tack the wires in place using the staplesprovided.
H . Locate the 2-pin obstruction sensorplug on the back of the
power unit. Carefully plug the connector onto the two
metal tabs located inside the notch at the rear of the porver
unit. Make sure locking tab is properly inserted as
shown. See Figure 32. Leave a small loop of wire that
attachesto the rear of the door opener power unit. This is
to ensure that the connector will not pull off the tabs if the
power unit movesduring operation.
DO NOT USE A STAPLE GUN.
Be sure to run the wires in a location where they will
not interfere with the operation of the door.
FIG,31
KeepWiresClearof
DoorMovement
Loop and Secure
ExtraWire
PowerCord
I
V
FlG. 32
Obstruction
SensorPlug
Receiving
Unit
SIapres
\
Locking
Tab
Sending
Unit
---'€;
ffi
-)rt"t
lX..r.r /
\
Distance
lnside
Opening
15D.1
\*>
IMPORTANT:
\ DistanceAbove Floor
(1" Higherthan ReceivlngUnit)
MAKE SURE
LOCKINGTAB ON
IS
z.PIN CONNECTOR
INSERTEDAS SHOWN.
2-Pin
Connector
P a g e1 5
SINGLELIGHTSOCKETMODELS
FIG.
Install one 100 watt light bulb into the single light socket.
SeeFig. 33.
DUAL LIGHTSOGKETMODELS
100WattBulb
Install two 100 watt light bulbs into the dual lamp socket.
Install lamphouse using the knurled nut to secure it. See
Fig.34.
NOTE: The maximum total wattage must not be more than
200 watts. It is suggestedthat rough service bulbs be used.
AUTOMATIGLIGHTOPERATION
ALL MODELS: The lights will come on when the door
opensor closes,and stay onfor 4-l/2 minutes,then automatically turn off.
FtG.34
Lamphousey'
SPECIAL LIGHT FEATURE "SAFE-T-SIGNAL''
Whenever any of the opener's safety features are activated,
the lights on the opener will flash until the next push of either
the transmitter or pushbutton.
NOTE: If opener is supplied with a four-function wall
console, the pushbuttons shown below WILL NOT be
used. Please refer to those instructions now (packaged
separately), then return to this page.
A. Strip about l/4" of insulation off each end of pushbutton
wire. Connect pushbutton wires to the two screws on rear
of pushbutton as shown in Figure 35.
B. Locate pushbutton in a convenient location at least 5 feet
above the floor and attach with the two wood screws
provided.
LightedPushbutton
FtG.35
StandardPushbutton
NOTE:DO
NOTALLOW
BAREWIRE
TO TOUCH
ADJACENT
SOLDER
TRACKS
/R^
(40d)
\w/
Front
FrG.36
Back
Front
KnurledNut
C . Run wire from pushbutton to power unit. Use staplesprovided to secure wire. DO NOT USE A STAPLE GUN.
Do NOT staple through wires. This will causea short. Do
NOT place wire close to the 120 volt power wires. Separate as far as possible. NOTE: If gnage has more than one
opener,keep pushbutton wiring separateas far as possible.
D. Strip about l/4" of insulation off other end of wire and
connect to the two screw terminals labeled "PUSHBUTTON" at rear of the power unit. SeeFigures 36 and37 .
Mount Entrapment Warning Label near the pushbutton.
An additional mechanical means (staples, screws, etc.)
may be required to securethis label to some surfacesif the
adhesive on the back of the label does not stick. See
Fisure 38.
MouruT THE PUSHBUTToNHIGHEB
IMPORTANT:
T H A N A C H I L D C A N R E A C HA N D I N A L O C A T I O N
WHEBETHE DOORIS EASILYVISIBLE.
Neven pASs UNDEBA MovtNGGARAGEDooR.
Back
FtG.38
Page16
16E.2
WARNING: KEEP TRANSMITTEROUT OF
REACHOF CHILDREN.
ALL MODELS
A. Locate the bank of digital code switches on rear panel of
opener.With a pencil or pen, flip any combination of
switchesto setyour own personalcode.SeeFigs. 39 and 40.
NOTE: All odd numbered switches are factory set to the
OPEN position. All even numbered switches are set to the
CLOSED position.
IMPORTANT: Do ruor LEAvErHE coDE swtrcHEs tN rHE
" A S P U R C H A S E D , 'P O S I T I O NO R S E T A L L S W I T C H E S I N T H E S A M E
FGGRadioUsageLimitations
CAUTION: The garage door operator and all accessory
radio equipment has been designed to Federal Communications Standards for Part 15 radio devices. Operation of this
device is subject to the following conditions: (1) This device
may not cause harmful interference; (2) This device must
accept any interference that may be received, including
interference that may cause undesired operation; (3)
Changes or modifications not expressly approved by Stanley
Home Automation, Division of The Stanley Works, could
void the authority of users to operate this equipment.
Frc.40
FtG.39
POSITION.
B. Squeezetransmittercaseas shown in Fig. 41 and remove
side panel. Side panel may be removed more easily by
twisting a nickel (5p) in coin slot on bottom of case.
C. With a pencil or pen, set the code switches in the identical
positions (pattern)that you set the code switcheson the rear
panelofthe opener.SeeFig.42.
----> Code Switch Open (Off)
<- Code SwitchClosed(On)
Code
Switches
on Rear of
Opener
D. Replaceaccesspanel on transmitter.
NOTE: Small red light on top of transmitterindicateswhen
your transmitteris sendingsignal. If the light does not come on
when transmitterbutton is pressed,check for a deadbattery.
E. Straightenthe radio antennaand point it straight down. See
Fig.43.
FtG.41
f
Single-Button
Transmitter
THETWO.BUTTON
"SIGNALBLOCICM''
TRANSMITTER
A. If your door opener was supplied with a two-button, handheld Signal BlockrM transmitter, the buttons are marked
DOOR and SECURE. The DOOR button is used to conrrol
your door, and the SECURE button is used to lock out or
disable use of the DOOR button on the transmitter.This
feature adds an additional level of security to your opener,
preventing others from opening your door with a singlebutton transmitter.
Red Light
B. To activatethe "SECURE FEATURE," your garagedoor
must be fully closed.Pressingthe SECURE button once will
activate (turn on) the system;pressingit again will
deactivate(turn off) this system.
FtG.43
I M P O R T A N T : U s r r u cy o u n w A L L - M o u N T EpDu s H B u r r o N
wrLL DEACTTVATE
(TURNOFF)THESECURE
FEATURE
tF tT tS
ACTIVATED.IT YOURDOOROPENER
IS CONNECTED
TO THE
Srnruley "FOUR-FUNCTIONWALL CONSOLE," ustNc
THE CONTFOLBUTTONOR VACATIONSWITCHON THE CONSOLE
wrLLDEACIVATE
(TURNOFF)THESECURE
FEATURE.
17C.4
Page17
n
WARNI
EITHERTHE FORCEOR THE LIMIT OF TRAVEL, RETESTTHE
DooR opENER. FltluRE To ADJUSTTHE oPENER PRoPERLY MAY CAUSESEVEREINJURYOR DEATH.
N G I B e p o nceo N N E c r N G
SAFETY
THESEIMPORTANT
POWER,PLEASEREVIEW
To REDUcETHE
lNsrRUcloNS. THEy AREDESIcNED
RlsK oF sEVEREtNJURyoR DEATH.PlEase READAND FoLCAREFULLY.
LOWALL INSTRUCTIONS
II
D. lr possteLE, usE THE EMERGENcvRELEASEoNLY wHEN
THE DooR ls cLosED. Use cauloN wHEN ustNc THls
R E L E A s Ew r r H T H E D o o R o p E N . W e e r o R B R o K E N
opERATE,oR pLAy wtrH DooR coNA. Neven LETcHILDREN
TRoLS.Keep neuorE coNTRoLAWAvFRoMoHILDREN.
SPRINGSMAY CAUSETHE DOORTO FALL RAPIDLY,CAUSING
INJURYOR DEATH.
B. Alwavs KEEpMovrNGDooR tN stcHT ANDAwAy FRoM
CLOSED.
PEOPLEANDOBJECTS
UNTILIT IS COMPLETELY
BALANCED.
E. KEEPGARAGEDOORSPROPERLY
See owruens MANUAL.Ar tmpnopERLyBALANoEDDooR
sERvlcE
couLD cAUSEsEvEREtNJURy.Have n QUALIFIED
ASSEMBLIES
MAKEREPAIRS
TO CABLES,SPRING
PERSON
HARDWARE.
ANDOTHER
NO ONE SHOULD CROSSTHE PATH OF THE
MOVINGDOOR.
MoNrHLy.
TnE caRaceooon MUST
C. Tesr DooRopENER
REVERsE
oN coNTAcrwrrHA 1-112tncn oBJEcr(on n 2
x 4 eoano laro runr) oN THEFLooR.lr aoJusrtnc
F.SAVETHESEINSTRUCTIONS.
A. Removecoverfrom powerunit.
To neoucETHERtsKoF ELEcrRlcsHocK,coNNEcrrHE
powERcoRDoNLyro A pRopERLy
cRouNDEo
3 pnoHc120
coRDoR cHANGE
voLTourLET.Do ruor usE AN EXTENSIoN
THEpLUGrNANywav. lr rHE pLUGooEs Nor Flr tNTorHE
B . Removeelectricalpowercord from openerandblackplastic strainreliefbushing.NOTE: Bushingcanbe removed
by compressing
with pliersandthenpullingout.
OUTLET, CONTACTA OUALIFIEDELECTRICIANTO INSTALLTHE
pRopER
To rHEuNrr,
ourLET.As soon As powERts AppLrED
C. Attachwhite leadto silver coloredterminalmarkedLl,
black leadto brasscoloredterminalmarkedL2, andgreen
groundingleadto groundscrewusingthe externaltooth
cup washerlocatedin accessorybag. Washeris required
to properlyretainthe wire.
TIIE LIGHTON THE OPENERSHOULDBLINK ONCE.
PERMANENTWIRING INSTRUCTIONS
I \
DtscotrxEcr powERAr FUsEBox BEFoRE
PRooEEDTNG.
Il
NOTE: Whererequiredby localcodes,openermustbe permanentlywired. Servicesof a licensedelectriciancan be
obtainedto performthe abovepermanentwiring.
A. The beamsensorcanbe alignedby movingthe sendingand
receivingunitsup or down andleft or right until the red
alignmentlight on the receivingunit comeson. The two
to movetheunit
thumbscrewsod thebottomcanbeloosened
left or right, andthe two mountingscrewsthatfastenthe
mountingbracketsto the wall can be loosenedto movethe
unitup or down.SeeFigure44.
lightcomeson,pivottheunit up or
B. Oncetheredalignment
down and left or right until you find the centerof the
operatingangle.Tighten all thumb screwsand mounting
screwswhen the systemis centered.This will prevent
possible
problems
whichmayoccurif thesystem
is
operating
angle.
notalignedin thecenterof theoperating
C. Finishsecuringall wire makingsurenot to breakor open
Loopandsecureanyextrawire.
anyof theconductors.
Page18
D. Replacecoverandswitchpoweron at fusebox.
BOTTOMVIEW
Lett
/
(
Left
I
Thumb
Screws
Right
Righl
FlG.44
Up/Down
SIDEVIEW
Red
Alignment
Light
Mounting
Screws
18C.2
ENGAGETRAVELERDETENT
OBSTRUCTION
TESTING
A. Pull the emergency release cord straight down and allow
mechanismto engagein slot.
A. Once the door can be cycled between the "factory set"
open and close positions without the system either stopping or reversing with the opener lights blinking, activate
the door in the closeddirection.While it is closing extend
your hands under the bottom edge of the door and try to
stop it. (The use of gloves is suggested.)Do not stand in
pathway of door or block beam sensor.The door should
reverseoff of your hands and begin to open with minimum
force. If it does not reverse,or if the force is excessive,
decreasethe close force until a lower level is selected.
ReferenceFig. 47.
B. Manually open door slowly until traveler engageswith
traveler carrjer.
C A U T I O N : T n e o p e r u e Rw t L L o p E R A r ED U R T N G
THEFOLLOWING
STEPS,IruSURC
NOTHING
IS IN THE
PATHOFDOORBEFORE
PROCEEDING.
NOTE: This operator is equipped with a thermal protector in
the motor circuit. If during the following steps the unit shuts
off and will not restart, wait 5-10 minutes for the motor to
cool down, then continue adjustment.
C. Push the transmitter button once. Keep the door pathway
clear of obstructions.The door should begin to close and
stop before reaching the floor. If it does not, refer to the
radio coding instructions (page 17) of this manual then
return to this section.
D. If the door begins to close then reversesand opens with
the lights on the opener blinking, either the beam sensoris
not properly connected and aligned (page 18) or the open
and closeforce adjustmentsmust be increased.
E. If a force is selectedwhich is lower than what is required
to move your door, the opener will reversewhile closing
or stop while opening with the lights flashing.
F. If the door is closing and an object passesbetween the
sending unit and receiving unit of the beam sensor,the
door will reverseand open with the opener lights blinking.
OPENAND CLOSE
FORGEADJUSTMENTS
A. The open and close force adjustmentslocated on the rear
of the opener select the amount of force the power unit
applies to open and close the garage door. See Fig. 45.
'l'hese
dials must be turned slowly in small increments
to insure the minirnum
amount of force is used to
open and closeyour door.
FrG.45
B. Beginning at low, turn force
OPEN
dials (1/10 turn at a time) to
increase door force until door FORCE
can be cycled between the
"factory set" open and close
positions without the lights on
the opener blinking. The door
should move for approximateCLOSE
ly 6 seconds.
B. Once the close force is properly adjusted,activatethe door
to open and try to stop it with your hands. Do not put fingers between door sections. The door should stop (not
reverse) with minimum force otherwise the open force
must be decreaseduntil a lower force is selected.
GLOSETRAVELADJUSTMENT
lSmall Black Knobl
A. Pushthe transmitterbuttonuntil the door closesand automatically stopsbefore reachingthe floor. Locate the small black
closetraveladjustmentknob on the bottomof the porverunit.
SeeFig 46.
B. Slowly turn this knob in the direction of the arrow (more
closetravel)until the door moves.The door should"inch" its
way closed.Repeatinching the door closeduntil it reaches
the floor. Continue to turn the knob until the door is secure
againstthe floor with the tube slightly bowed.
C. If the door reversesoff of the floor and opensturn the knob
slightly (ll4 turn at a rime) in the opposite direction of the
arrow and cycle the door again until the door is securely
closedwithout reversinsoff ofthe floor.
OpenTravel
Adjustment
Close Travel
Adjustment
NOTE:When door is closed,
the chain may sag below
bottom of tube.
FORCE
19E.2
P a g e1 9
ENTRAPMENTTEST
WARNING: SEVERE DAMAGE TO DOOR,
DOOR OPENEROR PERSONMAY OCCUR IF
THE CI,OSE FOI{CE ADJUSTMENT IS SET
NOTE: The tube acts as a shock absorberduring the opening
and closing of your garugedoor. When the door is fully closed,
there will be some tube bowing. This bowing minimizes the
stresson the door and door hardware.SeeFis. 48.
TOO HIGH FOR CONDUCTING THE FOLLOWING
TEST. Some doors require additional reinforcement to prevent
damage. Read "Door Reinforcement" section of this manual
(page l2) before continuing.
A. With the door open, place a I-l/2 inch object (or a 2 x 4
board laid flat) under the door opening. Activate the door in
closed direction. The door should contact the object then
reverse and open. If the door simply stops and does not
reverse,turn the black close travel adjustmentknob l/4 turn
in the direction of the arrow (more close travel) and test
agalfr.
B. Repeat this procedure until the door reversesoff of the 1I/2 inch object and opensbut can be closed securely against
the floor without reversing.SeeFig. 47
FlG.47
OPEN TRAVELADJUSTMENT
lSmall White Knobl
A. Activate power unit until the door opens and automatically
stops. Locate the small white open travel adjustment knob
on the bottom of the power unit. Slowly turn this knob in
the direction of the arrow (more open travel). The door will
"inch" its way open.
B. Continue to turn this knob until the desiredopen position is
selected.Do not force the door open any further than its natural open position. This may cause excessivestrain on the
door or door opener.Trackless doors should be at a slight
downward angle when fully open. ReferenceFigure 19.
BEAM SENSORTESTING
A. Push the hand-held transmitter to close the door. While the
door is closing, test the beam sensorby obstructing the
invisible beam.When obstructed,the red alignment light on
the receivingunit should turn off. The closing door should
stop, pausetwo seconds,then reverseand begin opening.
The lights on the door openershould flash.
B. Obstructingthe beam while the door is opening will have
no effect.
NOTE: If door fails to revelseof['ob.ject,discontinueuse and
contaotthe StanleyCustornelServiceDepaltment.
DIGITAL TRANSMITTER
Allows you to programtp to 1024
different personalcode settings.
n-r^vruEl
Lr,.-L^1\ufffuEt
t/ol1
t+7tt
rr c
vro.
24970 Canada
SIGNAL BLOCK TRANSMITTER
Order Number 24987U.S.
24972 Canada
LIGHTMAKER TRANSMITTER
Order Number 24898 U.S.
24972 Canada
Page 20
EXTERIOR DISCONNECT
LOCK
Used when you haveno separate
entranceto ihe garage.Should there
be a power failure, it will disconnect
the openerfrom outsidethe garage,
enablingyou to operateyour door
manually.
Order Number 24714
THAT'S IT -YOU'RE DONE! Pleasetaketime to readthe
remaining pagesand filI out the warranty registration card.
ELECTRIC KEYSWITCH
Used when you are out of your car
and want to enter your garage. By
insertinga key and turning it, the
door will openor close.
Order Number 49019
..
8'EXTENSION KIT
For use on eight (8) foot doors.
Order Number 24697
DIGITAL CODEKEYTM ENTRY
This unique,multi-codeentry system with telephone-typepushbutton
keyboardwill allow you to openor
closeyour door from outsidethe
garageby pressingyour personal
code.
Order Number 24718
20c.3
OPENERDOES NOT WORK
A. Make sure power cord is plugged into a properly grounded 3
prong 120 volt outlet. Plug in a drill or other electrical tool to
test for power.
DOOR CLOSES - THEN OPENS WHEN REACHING THE
FLOOR
A. Is there a rake handle, garden hose, snow, ice, etc. obstructing the
door? Remove the obstruction then try closing the door again.
B. If openerhas been cycled severaltimes, the motor overloadprotector may be activated. Wait approximately 10 minutes for the
motor to cool and then try again.
B. Due to climatic conditions many concrete floors will heave or
sink. Turn the (small black) close travel adjustment 1/4 turn
opposite the direction of the arrow on the cover, then review the
"Close Position" and "Entrapmentt' test instructions in this
manual.
C. If a four-functionwall consoleis being used,make sule the vacation switch is in the "UNLOCKED" position.
D. If door is severely out of balance, the opener may not be able to
exert enough force to move it. Make sure a1l locks are removed.
Pull the emergency disconnect cord to release the door from the
opener.Check to see if the openerwill operateif not connected
to the door. If openernow operatesreview "Door BalanceTest"
sectionof this manual.
HAND-HELD TRANSMITTER DOES NOT WORK OR HAS
SHORT RANGE
A. Review the "Radio Coding" instructionsin this manual. Someone else's radio controls may be interfering with yours. Try
changingyour code.
B. The battery in your transmitter may be dead or weak. Replace it
with a 9 volt batteryof the sametype.
C. Try moving or coiling the antennawire on the opener.
D. CB radios, computer equipment, powerful communication signals, and other dool openersmay causeundesirableinterference
and shorten radio range.
PUSHBUTTON DOES NOT WORK
A. Make sure the pushbutton wires are not touching each other at
the real of the opener or at the pushbutton.
B. If the wiles are not touching each other and the problem still
exists, disconnect the wit'es from the back of the opener and
"short" acrossthe two pushbuttonscrewsusing a key or screwdriver. If opener now operates,the pushbutton wires are probably shorted or broken.
LIGHTS FLASHING ON OPENER
A. This may be causedby activating the obstructionsystem that is
controlled by the open or close force adjustment on the rear of
the opener. If it requires more force to move the door than the
opener can supply this system will activate. A common cause is
a poorly operating door or an obstruction, Review "Door Balance Test" and "Open and Close Force Adjustments" in this
manual.
B. If the beam sensoris not aligned and working correctly, the door
can only be closed by holding the wall-mounted pushbutton. The
transmitter cannot be used to close the door. The tight on the
opener will flash and the door will reverse and open if button is
not held until the dool is fully closed.
OPENER ACTIVATES BY ITSELF
A. Somebodymay be using the sameradio code as you. DO NOT
leave radio code switches in factory set position. Review
"Radio Coding Instructions."
EXCESSIVE TUBE BOW
A. Check to see that the powerhead is securely mounted and the
door operatesfreely. Review "Door BalanceTests" in this manual. Is somethingobstructingthe door?
B. Review "Close Travel" and "Entraoment Test" sectionsin this
manual.
LIGHT STAYS ON
A. The light time delay on the opener will keep the light on for
approximately 4 1/2 minutes after the system has been activated,
then will turn it off automatically.
B. If openerhas a worklight switch (which is suppliedonly with a
four-functionwall console),slide switch to "OFF' position.
C. If opener has a pedestlianlight switch, (which is supplied only
with a four-functionwall console),the light will stay on for 4-l/2
minutes after the pedestriandoor is opened.
NOT ENOUGH OPEN OR CLOSE TRAVEL ADJUSTMENT
A. If you operatedthe power unit before it was completelyinstalled
or if you did not position the traveler the correct distance from
the tube support, the limits and traveler may be out of synchronization.
B. Turn off power, remove and relocate traveler by disconnecting
chain from sprocket,re-assembleand try adjustingagain.
SOMETHING BROKE - NEED ASSISTANCE?
Identify the part in this instructionmanual(on the next page)then
contactyour local Stanleydealeror use the Stanleyfree help line:
1-800-52r-5262
Referencethe properpagesin this manualfor all adjustmentsand
settrngs.
B . If the problem has been locatedin the radio conrrols(other than
batteries) return only the kansmitters and the control board. DO
NOT return the complete opener.
C. If something obstructs the door while closing, it will reverse and
open - lights will flash. If something obstructs the door while
opening,it will stop - lights will flash.
z l w
Page21
NOTALL PARTSSHOWNARESUPPLIED
HeaderBracket
360.3088
lY^10-eorunexit
@
Chain& Cable
ldlerTube Assembly
(Suppliedin Swaged
Tube Kit)
Traveler
AssemblyKit
24836
s
Y _
Lighted
Pushbutton
24861
I T
I E
.-d
Shoulder
Bolt
600.0201
,M
71
SingleButton
Transmitter
2 4 9 1 1- U . S .
24970 - Canada
CapacitorKit
114HP - 24857
1t3-1t2HP - 24858
SignalBlock
Transmitter
2 4 8 9 7- U . S .
24972 - Canada
CapacitorClamp
360.2928
<.\
DDiT Terminal
Board
6 360.3105
MountingAngle Kit
24613
Lightmaker
Transmitter
24898 - U.S.
24972 - Canada
ControlBoard
SpecifyModel
Cover
- u.s.
24700
24728 - Canada
StrainBushing
360.0949
LimitScrew
3702930
,
l c
g
GearcaseBodyAssy
370.1947
#10 Screws
6 2 51 1 5 9
,il
360.2258
MotorAssy.
-370.3022
1/4-113HP
1/2HP- 370.3027
H;"**:.F.
Single
Dual
PARTSNOTSHOWN:
370.2965WireHarness
24075 BeamSensorAssy.Kit
WallConsoleKit
24705Four-Function
370.2166ChainMasterLinks(2)
Page 22
360.2401
LimitActuator
Assy.
370.3020
OutputWormwheel
360.3433
GearcaseCover
360.2421
LimitKnob
(wht.) 360.23e4
g
RetainingRing
615.0026
LimitKnob
(Blk.)360 2395
SensorBoard
921.3471
zzv.o
LUBRICATION:
For easy operation and long life, lubricate
all moving parts of your door with light oil several times yearly, including roller shafts. Do not lubricate tracks or surfaces
of nylon rollers.
DOOR BALANCE TEST: Check door balance at3/4 open,
mid-point and 314 closed positions. Refer to "Door Balance
Test" in this manual.
OPEN AND CLOSED SETTINGS: Make sure the open
and closed limits are properly adjusted.Refer to manual.
EMERGENCY RELEASE: Close galt;gedoor and pull the
red emergencyreleaseknob to ensurethe door can be released
from the opener.
HARDWARE: Inspect the chain/cable tension and retighten
all nuts and bolts.
Before using this phone number, please review the
"Troubleshooting" information on page 2I and the
"PartsList" guideonpage22.
Should you still have any questionsabout installationor
operation, a qualifiedStanleyTechnicianwill diagnoseyour
problemand provideyou with the assistance
necessary
for
your DO-IT-YOURSELFinstallationor service,
SAFETY: The ENTRAPMENT TEST is the single most
important step in the installation of your garagedoor opener.
The door must reverse when it comes in contact with a l-l/2,,
high solid object placed on the garage floor. If door does not
reverse refer to the Closed Position and Entrapment Test
Instructions in this manual or contact a door system professional.
Failure to comply with this requirement may result in serious or fatal injury to anyone trapped by a closing garage
door.
CAUTION: Drscorurrruur
usAGE
ANDcoNrAcrAN
AUTHORIZEDSTNruICY DEALER OR THE STAruICY
C u s r o m e RS e n v l c eD e p n R r m e r u
ATN yr t M EA
MALFUNCTION
IS OBSERVED.
CALLTOLLFREE
1.800.521-5262
Please have the
MODELNUMBERand
DAIE CODEwhen calling.
During the waranty period, if the product appearsas though it may be defective, call our Toll Free service before removal of the unit.
A Stanley Technician will diagnosethe problem and promptly supply you with the parts for DO-IT-YOURSELF repairs, or provide
you with shipping instructions for factory repair or replacement.
Need help after the warranty period?
Need help obtaining parts, service, and accessories?
Refer to the Stanley ProfessionalDealer List provided with
the unit or seeyour yellow pageslisting for STANLEY under
the following headings:
. Door Operating Devices
. GarageDoor Openers
23C.4
Your local Stanley Dealer stocks parts and accessoriesand
can insure that you are ordering the correct item.
If you are unable to locate I local source for service or parts,
pleasecall us at 1-800-521-5262,and ask for the Consumer
Order Desk.
. GarageDoors and/or Garages
. Or your Local Staaley Dealer
Page23
HOTNEAUTON'IAflON
FORYOURRECORDS
DatePurchased
WherePurchased
ModelNumber
DateCode
DateInstalled
DO NOTTHROWTHISMANUALAWAY!
Keepin a SafePlacefor FutureReference
NOTICE
C H A I N& C A B L EA S S E M B L Y :
maybe pre-assembled
andsupplied
on a rollas shownin Figure1,
Thechainandcableassembly
in a plasticbagandcoilas shownin Figure2 withan extra
andsupplied
or it may notbe assembled
connect
in
Fiqure
themas shown
3.
masterlinkto
F I G U R1E
2
FIGURE
dffi
Cable
Chair/Cable
Chain
MasterLink
F I G U R3E
-1--t
Link
- Master
Retaining
Clip
Chain
I D L E RT U B EA S S E M B L Y :
lf thepulleywasnotpre-assembled
pinand lockclipto
to theidlertube,usethe1-112'clevis
assemble
themas shownin Figure+.
F I G U R4E
1 - 1 1 2 ' C l eP
v iisn
LockClip
023.0269
STANLEYDOOROPENERLIMITED
WARRANTY
YourStanleygaragedoor openerand remoteradiocontrolsare warrantedagainstdeficienciesin materialand workmanshipfor a specificperiodof time based
on which model numberyou have,providingrecommendedinstallationand maintenanceproceduresare followed.This warrantyis in lieu of all other warranties,
expressedor implied(someStatesdo no allowlimitations
on how longan impliedwarrantylasts,so this limitation
may not applyto you) and shallbe
considered
void if damagewas due to improperinstallation
or use,connection
of improperpowersource,or if damagewas causedby fireor lightning.
The
Manufacturerwill not be responsiblefor any laborchargesincurredin the removalor replacementof deficientparts.In case of failuredue to deficientmaterialor
workmanship
duringthe warrantyperiod,the electronic
components(controlboardand transmitters)
or the completegaragedooropenerwillbe repairedor
replacedat the Manufacturer's
optionat no charge.For informationon this warranty,you may call, toll{ree BOO-521-5262.
New or factoryrebuiltreplacements
will be used.Replacementparts are warrantedfor the remainingportionof the originalwarrantyperiod.In the eventthe warrantyregistrationis not returned,the
warrantyperiodabovedatesfrom date of shipmentfrom Manufacturerratherthan date ol purchase.This warrantygivesyou specificlegal rights,and you may
also haveother rightswhichvary f rom Stateto State.For use with 120 volt,60 hz. currentonly.
STANLEYDOOROPENERMODELSANDWARRANTY
PERIODS
' ST100,
MODELS
ST101: Garage
DoorOpener
andremote
radiocontrols
arewarranted
fora periodof one(1) yearfromdateof purchase.
Themotoriswarranted
forone(1)year
MoDELS-ST200'ST201'ST300:GarageDooropenerandremoteradiocontro|sarewanantedforaperiodofone(1)year|romdateofpurchaseThemotorisw
M9?FL D1000:GarageDoorOpenerandremoteradiocontrols
arewananted
fora periodof one(1)yearfromdateof purchase.
Themotoris warranted
forseven(7)years
- ST301
MODELS
Garage
DoorOpener
andremote
radiocontrols
arewananted
fora periodof one(1)yearfromdateof purchase.
, SD350:
Themotoriswananted
foreight(B)years.
MODEL- SD351:GarageDoorOpenerandremoteradiocontrols
arewananted
for a periodof one(1)yearfromdateof purchaseThemotoris wananted
fortwelve(12)years.
MODEL ST400:GarageDoorOpenerandremoteradiocontrols
arewarranted
fora periodof two (2)yearsfromdateof purchase.
Themotoris wananted
foreight(B)ye'ars.
MODEL- ST401
: GarageDoorOpenerandremoteradiocontrols
arewarranted
fora periodof two (2)yearsfromdateof purchaseThemotoris warranted
lor ten(10)years
MODEL- ST500:GarageDoorOpenerandremoteradiocontrols
arewarranted
fora periodof two(2)yearsfromdateof purchase.
Themotoris warranted
fortwelve(1'2)years.
MODELS SD450,SD451,SD550,SD551:GarageDoorOpenerandremotecontrols
arewarranted
fora periodol three(3)yearsfromdateof purchase.
Themotoris wananted
forthe LIFETIME
of theopenerfortheoriginalpurchaser
in theoriginalinstallation.
- 58600,ST501,ST502:GarageDoorOpenerandremoteradiocontrols
MODELS
arewarranted
fora periodof two (2)yearsfromdateof purchase.
Themotoris wananted
for
purchaser
theLIFETIME
ol theopener
fortheoriginal
in theoriginal
installation.
MODELS SL700,D2000:GarageDoorOpenerandremoteradiocontrols
arewananted
lor a periodof one(1)yearfromdateof purchase.
Themotoris warranted
forthe
purchaser
LIFETIME
of theopener
fortheoriginal
in theoriginal
installation
WHEN ORDERINGREPLACEMENT
PARTS.PLEASE
SUPPLYTHE FOLLOWINGINFORMATION:
SHOULDYOU HAVE
A N YQ U E S T I O N S
CONCERNING:
1.Typeof problem:
. IN WARRANTYSERVICE
.INSTALLATION
2 Partnumber& description
from homeowner's
manual.
TOLL-FREE
CALL
-800-521
-5262
1
3. Modelnumberand date code of doorooener
ANDASKFOR
DEPARTMENT
SERVICE
on data plate located on end Danel at back of
powerunit See illustration
below
A TRAINEDSERVICETECHNICIAN
WILL BE PLEASEDTO HELPYOU.
Pleasehavethe MODELNUMBERand DATECODEwhen callino.
For After WarrantyService,ConsultYourLocal
YellowPagesforYourNearestStanleyDealer.
DATA PLATE
WARRANTYREGISTRATION
NAME
T / O D E LN O
DATECODE
ADDRESS
D A T EP U R C H A S E D
P R I C EP A I D
CITY
STATE
ZIP
PHONE
CITY
STATE
D E A L E RN A M E
MARKETINGQUESTIONNAIRE
Pleasecircle your answer to the following questions.Thank you.
1
lsthisopeneragiflitem?
yes
No
2
Did you previouslyown an opener?
3
What influencedyou the most to buy this
opener?
. Friendhas opener . NewspaperAd
7
. ln-storedisplay
. Literature
. T.V ad
. Stanleyreputation
. Friendhas other
. Price
8
Stanleyopenermodel
. LightControl
9
Who actuallydecidedto buy
Yes
4
a Stanleyopener?
Self
Spouse
No
Other
5
HaveyoueverseenaTVadforStanley 10 Lengthoftimetoinstall?
Openers?
1 to 2 hrs,
3 to 4 hrs
5 to 6 hrs
Yes
over 6 hrs
No
6
Haveyou ever hearda radioad for
StanleyOpeners?
Yes
No
11 On what type of door was openerinstalled?
Yourage?
Why did you purchaselhis openerversusanother
model?
Under25
2'lo 40
41 lo 54
55 or over
Who jnstalledyour opener?
Yourself Paid Pro
Friend
Did you move into your home within
last 6 months?
,:Sectionaltrackdoor
One-piecetrackdoor
Tracklessdoor
pivot door
Which add accessoriesdid you purchasewith your
opener?(i e , hand transmitter)
YourComments
IT'STHELAW
GARAGEDOOROPENERSMUSTBE PROVIDED
WITHAN EXTERNALENTRAPMENT
PROTECTION
SYSTEMSUCHAS A "BEAM SENSOR''TOHELP
PROTECTAGAINSTENTRAPMENT
BETWEENTHE
BOTTOMOFTHEGARAGEDOORANDTHEFLOOR.
THISSYSTEMCAN NOTBE
DEFEATED
OR "BY.PASSED'"
THE DOORCAN NOTBE CLOSEDUSINGTHE
HANDHELDTRANSMITTER
IFTHE BEAMSENSOR
SYSTEMIS NOTCONNECTED
AND PROPERLY
ALIGNED.IT CAN,HOWEVER,
BE OPENED.
IF THISSAFETYSYSTEMIS NOTPROPERLY
CONNECTED,THE
DOORCAN ONLYBE CLOSED
BY HOLDINGTHEWALL.MOUNTED
PUSHBUTTON.
EFFECTIVE
FOROPENERSMANUFACTURED:
AFTERJANUARY1, 1993. UNITEDSTATES
AFTERJANUARY1, 1994, CANADA;
WARRANTY& ACCISSORYINFORMATIO NSIDE
Door SalesCom
SalesReceipt
Inc.
43678Gratiot. Clinton Township,Michigan 48036
(s86)468-97
87 . FAX (s86) 463-3299,800-462-2593
www.fjfdoor.com
pqo/vpr
ysERt//cE
fl,EnGElvc
cAll A/vlr//r/E
Date
S a l eN o .
4ll7/2012
8794
PaymentMethod
Rep
Cash
KL
Rate
Amount
SoldTo
CASH SALE
C h e c kN o .
Item
Description
l/8"
1/8"rawcable
Multi-Purpose
L... Multi-Purpose
SprayLube6oz
Qtv
U/M
l0
I
1.40
5.95
Subtotal
14.007
5.957
ste.es
d
SalesThx (6.0%)
srzo
Total
$2r.r5
Automatic
Garage
Door
0pener
Safety
&
Maintenance
Guide
TtrT
Garage
door
opener
safetyAnautomatic
decision
A garage door is the Largestmwing object in the
home. An improperly adjusted gerdge door opener
catt exert deadly force when the door closeswhich couldlead to entrdpment of children or aduhs
and subsequent injury or death from asplqxiation.
lsEveryone's
Safety
Business
Automatic garagedoor openers are
installed in millions of households.Proper
installation, operation, maintenance and
testing of the garagedoor and automaric
opener are necessaryto provide a safe,
trouble-free product, An improperly
adjustedgaragedoor opener can exert
deadly force when the door closes.This
could lead to serious injury or death from
being hit by a closing garagedoor or from
becoming trapped under the door.
Carelessoperation and allowing children to
play with or use garagedoor opener controls
are also dangerous situations that can lead
to tragic results. A few simple precar:tions
can protect your family and friends from
potential harm. Pleasetake a few minures
to read the following maintenance and
safety tips. Then check the operation of
your garagedoor and opener to ensure they
function in a safe and trouble-free manner.
Garage
Door
Openers
AreNotToys
Do not standor walk r-urdera
moving doorl Do not let children
play "beatthe doorl' It is very
dangeror-rs
and can result in serior,rs
injury or death.Adulrc shouldset
a goodexample.
Some of the following precautions
and warnings are identified with
this warning symbol. This syrnbol
indicatessome o{ the conditions
that can result in serious iniurv
or death.
Keep transmitters and remote
controls or-rtof reach of children.
Do not let children play with or
usc the transmitters or remote
controls.
When using the pushbuttonor transmitter,
keep the door in sight until ir cornpletelycloses.
Teach children to never plav under or near an
open garagedoor,Do nof aliow childrento run
undera closingdoor.
Testing
TheOpener
The pushbuttonwall control
shouldbe out of reachof children
(at least5 feet frorn the floor) and
awayfrom all moving parts.
Mount and usethe button where
you can clearly seethe closing
garagedoor.
Teach
YourChildren
About
Door
Garage
Safety
Discussgaragedoor safetywith your children.
Explain the dangerof being trappedunder the
door,Do not let childrenplay with or usethe
pushbuttonor transmltter.
a 1 inch pieceof wood is best,if you don't have
one,useaZ x 4laid flat. Test the balanceof the
door, asdiscussed
on the back page,before
performingthe reversaltest.
Push the control button to close the door. The
door opener must reverse and open the door
when it strikes the wood. If the opener does not
reverse,have it repaired or replaced.Also
consider replacement of the garagedoor opener
if it is an older model, Have a qualified
individual adjr-rst,
repair or replace the parts.
Routine
Maintenance
Can
Prevent
Tragedies
There are routine maintenancestepsthat you
shouldfollow once a month. Review your
owner'smanual for both the door and door
opener.If you don't have the owner'smanuals,
contact the manufacturer(s)and requesta copy
for your specificmodel(s).Look for the opener
model number on the back of the power unit,
Look at the garagedoor springs,cables,rollers,
pulleysand other door hardwarefor signsof
wear.If you suspectany problems,have a qualified personmake repairs.The springsand
relatedhardwareare under high tension and
can causesevereinjury when handled
irnproperly,
WARNING - Springsare under
high tension. Only qualified
individuals should adjust them.
Test the force setting of your garagedoor
openerby holding up the bottom of the door as
it closes,If the door doesnot reversereadilv.
the force is excessiveand needsadjusting.Yor-rr
garagedoor openerowner'smanualwill explain
how to adjusrthe forcesensitivity.A qualifled
individualshouldadjustit, To avoidentrapment,
be sureto perform the 1 inch reversingtest after
any repairsor adjustmentsare madeto the
garageooor or opener.
Many garagedoor openerscan be equipped
with accessory
safetydevices.Consideradding
an electriceyeor edgesensorasan extra
measureof safetyto protectagainstentrapment.
e-=-"-,\
-\
Rollers and hinges of a garagedoor require
periodic h-rbrication.Use a spray silicone or
lighmeight hor-rseholdoil according ro the
instrr-rctionsin yor-rrowners manual.
Periodicallytestthe balanceof your door.Start
with your door closed.Disconnectthe garage
door openerreleasemechanismso you can
operatethe door by hand.You shouldbe ableto
lift the door smoothlyand with little resistance.
It shouldstayopen aroundthreeto four feet
abovethe floor. If it doesnot, it is out of
balance,Have it adjustedby a professional.
DoorOpener
Garage
Safety
Decision
AnAutomatic
Automatic
Door
Garage
0pener
Safety
&
Maintenance
Guide
trTTTTTT
Thke a few rninutesto inspectand test your
garagedoor system.Make rnonthlyinspection
and testinga part of your regularroutine.
Saferyis everyone's
business.
Make garagedoor
openersafetyautomaticin your home.
This irnportant information is providedby the U.S.
ConsumerProductSafetvComrnission,the National
y o a l i t i o nf o r
S a f e t yC o r r n c i l a n dt h e I n d r r s t r C
Automatic GarageDoor Opener Safety.
National
Safety Council
ForAutomatic
Garage
DoorOpener
Salety
o 1991TheInduslry
Coalilion
Printed
in U S A
Garage
door
openel
safetyAnautomatic
decision
A garage d.ooris the largest mouing object in the
home. An improperly arliusted,garage d.ooropener
cctn exert deadly force when the door closeswhich could Lea.dto entrdpment of children or aAults
and subsequent injury or d"eathfrom asphyxiation.
">
/
Pobierz
Tylko małe przypomnienie. Możesz wyświetlić dokument tutaj. Ale co najważniejsze, nasza sztuczna inteligencja już go przeczytała. Może wyjaśnić złożone rzeczy w prosty sposób, odpowiedzieć na Twoje pytania w dowolnym języku i pomóc w szybkiej nawigacji nawet po najdłuższych lub najbardziej skomplikowanych dokumentach.
Reklama