BETTER-BENCHe ADJR™ INSTALLATION
USING INVISABOLT™ SUPPORT SYSTEM
MOUNTING TO A 2X6 STUD WALL IS RECOMMENDED
MINIMUM 2X4 STUD WALL WITH A DIRECT CEILING CONNECTION IS REQUIRED
E TERN INVISABOLT SU RTR NREMENT o
Mounting wall to wall up to 36": No additional support required Need Help? Visit us at:
Mounting wall to wall up to 63": Two(2) INVISABOLT supports required www.innoviscorp.com
Mounting on back wall and one side wall up to 36”: Two(2) INVISABOLT supports required (800) 382-9653
Mounting on back wall and one side wall up to 63”: Three(3) INVISABOLT supports required
Mounting with no side support up to 36": Two(2) INVISABOLT supports required
Mounting with no side support up to 48”: Three(3) INVISABOLT supports required
Mounting with no side support up to 63" max span: Four(4) INVISABOLT supports required
INVISABOLT™ SUPPORTS ARE NOT NEEDED WITHIN 6” OF A SUPPORTING WALL MOUNTED CONNECTION
4x6 Minimum structural wood blocking must be installed flush to front face of studs prior to placement of
tile substrate. Secure with (4) 16d nails at each end of block. Locate horizontal centerline of blocks to align with
centerline of BB-ADJR. Wood blocking must extend to the next wall stud beyond the BB-ADJR width. Install tile
substrate per manufacturer's directions.
2. Expand bench to width desired, being sure to keep large holes in
_ front face of the BB-ADJR aligned for both halves. Secure the final
dimensions as detailed in BB-ADJR installation instructions.
3. Viewing from front of bench, locate the 1-1/8" holes that are visible after bench has been expanded
and secured. These are the mounting locations for the INVISABOLT! (drill out exposed metal if necessary)
Temporarily place bench in final location and mark centerline of INVISABOLT locations on substrate (you may wish to cut 2 or 3
temporary legs from scrap wood to provide support when completing the following operations!) Set bench unit aside.
Using a 5/8” bit, drill INVISABOLT mounting locations through substrate into preinstalled blocking
for a combined depth of 4". Keep drill straight, level, and as perpendicular as possible to
wall surface. Be careful not to penetrate other side of finish wall. Slide plastic insulator onto the |
INVISABOLT and insert through the large hole in front face of BB-ADJR unit and thread into 5/8”
predrilled locations. Tighten the bolts until INVISABOLT face “just” makes uniform contact with
front face of BB-ADJR. Provide a sufficient amount of additional caulk or liquid waterproofing
material to protect INVISABOLT penetration through bench and wall.
Follow Better-Bench® ADJR standard method mounting instructions Steps 2-4 to secure the
bench to final position and fill with appropriate fill material. Do not “bury” INVISABOLT head with
mortar. Allow mortar to cure at least 48 hrs. prior to continuing. Tighten INVISABOLTs 1/4-1/2 turn or until resistance is about 15 Ibs.
torque. Do not over tighten or cause a deflection in face of bench.
Apply finish material to top of bench, face and exposed ends.
Also consider Recess-It® tile ready
niche systems for your next project!
All Innovis Corporation products are proudly made in the USA!
INVISABOLT™ MOUNTING SYSTEM FOR BETTER-BENCH® BB-ADJR™
IMPORTANT NOTIFICATION
PROVIDE ONLY THE NEW VERSION BB-ADJR FOR USE WITH THE
INVISABOLT MOUNTING SYSTEM!!!
THE PICTURE BELOW IS THE NEW VERSION BB-ADJR™
NOTE THE FOUR LARGE HOLES IN THE BACK OF THE UNIT
THESE ARE THE INVISABOLT MOUNTING POINTS
THIS IS THE OLD VERSION BB-ADJR™
USE THIS UNIT FOR WALL TO WALL MOUNTING AND/OR WITH BT-17S ONLY!
NO HOLES
< >
QUESTIONS????
CALL US AT (800)-382-9653 OR (916)-361-2601 M-F 7:30—3:30 PACIFIC TIME
INNOVIS CORPORATION 3790 HAPPY LANE, SACRAMENTO, CA 95827
">