Cleveland 21CGA5 Service Manual
Add to my manuals
18 Pages
Cleveland 21CGA5 is a mechanical timer-based steam generator designed for cooking and steaming food. It features a timed/manual switch for precise cooking control, an amber light timer for clean light indication, and a buzzer for signaling the end of the cooking cycle. The unit includes a descaling indicator and reset switch for easy maintenance, and a 3-minute timer for flushing and cooling the drain after use.
advertisement
▼
Scroll to page 2
of 18
Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and equipment they service. Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage resulting from use of, improper use of, or failure to use the information contained in this document. Cleveland Range, LLC has made every effort to provide accurate information in this document, but cannot guarantee that this document does not contain unintentional errors and omissions. The information in this document may be subject to technical and technological changes, revisions, or updates. Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or updates. Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out / tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas, electric, and steam powered equipment and / or appliances All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of operation according to OSHA approved practices during any servicing of Cleveland Range equipment Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date knowledge, skills, materials and equipment. Cleveland Range, LLC Ph: 1-216-481-4900 Fx: 1-216-481-3782 1333 East 179th St., Cleveland, Ohio, U.S.A. 44110 Visit our Web Site at www.clevelandrange.com CLEVELAND RANGE 21CGA5 SEQUENCE OF OPERATIONS STEAMCRAFT ULTRA 5 Mechanical Timer 1. To turn the unit on, depress the red on/off rocker switch. 2. 115 VAC is sent to the red indicator light. 3. 115 VAC is sent to the normally open drain valve closing it. 115 VAC is sent through the normally closed water level (top) float switch to the coil of the R1 relay • The R1 relay energizes • The R1 contacts close 115 VAC is sent to the fill solenoid 5. The fill solenoid opens and the generator fills through the drain valve. • The water fills to the normally open low water cut off float switch (bottom float). • The float is lifted by the water and the switch closes. • The water fills to the normally closed water level (top) float switch. • The float is lifted by the water and the switch opens. • With the switch opened 115 VAC is removed from the coil of the R1 relay. • The R1 relay deenergizes and 115 VAC is removed from the fill solenoid and the unit stops filling • When the water level drops, the operational water float drops closing the switch and energizing the R1 relay • The R1 contacts close 115 VAC is sent to the fill solenoid. The unit fills back to the proper level. 4. 6. When the timed/manual switch is in the timed position and time is on the timer • 115 VAC is sent from the timer to the R3 relay coil. • The R3 relay energizes • The R3B contacts close sending 115 VAC to the timer motor • The R3A contacts close sending 115 VAC through the optional door switch to the condensate valve and the primary of the 24 VAC ignition transformer. • 115 VAC is sent to the #4 terminal on the clean light timer. • The clean light timer counts down from the set time (time is set by dip switches on timer) • 115 VAC is sent to the amber light in the clean light switch. • The light is turned off and the clean light timer is reset by depressing the clean light timer switch. • With the sight glass filled the L.W.C.O. float will be raised and the normally open switch is closed. • 24 VAC is supplied from the secondary of the transformer through the L.W.C.O. float switch to the ignition module. • • • Spark is sent to the igniter. 24 VAC is sent to the gas valve. • The gas valve opens to the first stage (.7” W.C. natural gas and 2.25” LP) allowing gas to the burner. • 6 to 8 seconds later the valve opens to the second stage (3.5” W.C. natural gas and 10” W.C. LP) When the gas is ignited the ignition module detects at least 1.5 micro-amps DC through the flame and burner ground wire. • If the 1.5 micro-amps DC is not detected in 4 seconds the ignition module locks out and has to be reset by removing 24 VAC to the module. This can be done by turning the steamer on and off. 7. With water in the generator and flame heating it, steam is made and directed into the cooking chamber. 8. The steamer will continue to steam until the timer runs down. • When the timer times down 115 VAC is removed from the R3 relay. • The R3 relay de energizes. • The R3B contacts open removing 115 VAC from the timer motor • The R3A contacts open removing 115 VAC from the heat circuit • 115 VAC is sent to the 3 second timer • 115 VAC sent to the buzzer for three seconds. 9. The steamer is turned off by depressing the on/off rocker switch. • 115 VAC is removed from the heat and timer circuits. • 115 VAC is removed from the drain valve. • 115 VAC is sent to the 3-minute timer and water is sent in to the now open drain valve flushing and cooling the drain. 78 3 2 4 1 115VAC 6 5 L NO R1 L NO 25V ( GND ) L.W.C.O. FLOAT DOOR SWITCH (SCS OPT) R3 TIMED C B A WHT DESCALE INDICATOR & RESET SWITCH FILL VALVE R1 BUZZER 3 SEC TIMER 2 24V L106495 P TRANSFORMER 120V CONDENSER VALVE DRAIN VALVE REMOVE WIRE A-B & C-D WITH INTERMITTENT BLOWDOWN OPTION R2 ( OPT ) 1 3 OPERATIONAL WATER FLOAT NO RINSE VALVE A STEAMCRAFT 5.1 GAS, MECHANICAL TIMER BLK DESCALE TIMER 3 2 R D BLOWDOWN TIMER (OPT) NO C MANUAL POWER SWITCH 3 MIN TIMER 1 TIMED R3A NO R3B C C NO MOTOR NC 3 1 R2 3 1 R2 NO 25V VALVE VALVE IGNITION MODULE IGNITOR ( OPT ) C HEAT STANDBY TIMER 2 NC C ( OPT ) 2 ELECTRO-MECHANICAL TIMER MANUAL C IGNITOR GND GAS VALVE STEAMCRAFT 5.1 GAS w/MECHANICAL TIMER BLK LT BLU 3 2 1 17 18 LT BLU WHT BLK WHT BLK BLK ORN C NO PNK 13 BLK 21 BLK YEL BRN 9 RED ORN/BLK 19 6 BLU PNK WHT WHT/BLU WHT/BLK NC LT BLU R3 YEL TB 10 23 25V WHT VALVE VALVE REMOVED W / OPTIONAL DOOR SWITCH ( SCS ) 25 BLK GROUND 25V LT/BLU 2 ORN WHT/BRN RED 1 LT BLU ORN RED BLK BLU BLK YEL YEL 8 R1 BRN WHT/BLU TAN WHT/BLK WHT/GRA 16 ORN BLU WHT/GRA 3 2 4 4 78 TAN 3 2 1 1 6 5 ORN YEL 2 11 7 3 1 RINSE FILL 12 12 12 13 20528 - TRANSFORMER 24V 104224 - TIMED/MANUAL SWITCH 14 20304 - GROUND LUG 3 20478 - 3 MIN TIMER 15 106461 - LINE CORD 4 19994 - DESCALE INDICATOR RESET SW. 16 1065681150 - IGNITION CABLE 5 106911 - DESCALE TIMER 17 20477 - 3 SEC TIMER 6 108880 - DOOR SW ( SCS ) MAGNETIC 18 110198 - MOTORIZED TIMER ( TO COND SOL ) 7 106580 - HEAT STANDBY TIMER 19 41350 - BUZZER RED 8 44168 - TERMINAL BLOCK 20 106541 - INTMT BLOWDOWN TIMER 9 103726 - FLOAT ASSEMBLY 21 105966 - RELAY WHT BLK ORN BLK 2 1 WHT RED RED R2 GRN 3 WHT RED RED GRN 19993 - POWER SWITCH 2 ORN 20 BLK WHT 1 10 21 GRN 11 GRN 15 24 PARTS LIST 8 2 BLU COND INTERMITTENT BLOWDOWN OPTION N 22 GRN TAN RED ( THRU SCS, IF INSTALLED ) WHT/BLU BLU RED ORN WHT WHT/RED 7 YEL 5 WHT BLU BLU GRN BLK 3 2 1 RED 3 14 WHT WHT/BLK N GRA WHT/GRA WHT/BLK BRN BLU 10 44164 - TERMINAL BLOCK 22 300092 - IGNITOR 11 22221 - DRAIN VALVE 23 03546 - IGNITION MODULE 12 22218 - WATER SOLENOIDS 24 106400 - GAS VALVE ( NAT ) 25 1064001 - GAS VALVE ( LP ) 105966 - RELAY P106495 P Descaling Procedure-SteamCraft Ultra and Gemini Series How Much DISSOLVE to Use Model Dissolve Ultra 3 1/2 Gallon Ultra 5 1 Gallon Ultra 10 (Elec.) 1 Gallon (ea.) Ultra 10 (Gas) 1½ Gallon Gemini 6 & 10 1 Gallon (ea.) 6. Let the descaler soak in generator for approximately one hour: 7. After one hour, turn the unit power Off: This will drain and rinse the generator for about 3 minutes. 1. Turn the unit OFF and open the doors: This will drain and rinse the generator for about 3 minutes. 2. Turn the unit power back On: The generator will begin to refill with water. 3. Select Timed with the Timed/Manual switch: DO NOT start the timer, since you do not want to heat the water during descaling. Leave the doors open. 4. Remove descaling port cap and add with the specified amount of DISSLOVE: (See chart above) Do this while the unit is refilling. The generators can take-up to 8 minutes to refill. 5. After refill has stopped, add extra tap water into the descaling port until liquid is seen entering the cooking cabinet. Note: Ultra 10 gas will have liquid coming out of the drain, Adding extra water when descaling will raise the descaling solution higher than the normal fill level, allowing the DISSOLVE to work on sensors and surfaces above the water line Note: Some SteamCraft Ultra models (the electric powered Ultra 10 and Gemini 6 and 10, for example) have two generators and two descaling ports. Both units should be descaled at the same time, using this procedure 8. After the 3-minute drain cycle completes, turn the unit back ON. After the filling has stopped, add water until liquid enters the cooking compartment (or drain for the ultra 10 gas), and then turn the unit OFF. This will drain and flush any residue from the water level control assembly. Replace descaling cap. 9. After the 3 minute drain cycle completes, Turn the unit ON and set the Timer for 20 minutes: Make sure the Time/Manual switch is in the timed setting and the doors are closed. 10. When the timer times out (after 20 minutes) turn the power Off: This will drain and rinse the generator for about 3 minutes. This ends the descaling procedure. You can now turn the unit back on and resume normal startup and cooking operations.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement