The Excalibur 168 Map Filter Utility software

(“ad16to32.exe”) enables users of AD5400 or AD5500 to convert their data files from 16 bit to 32 bit format for use with the AD168 matrix switcher/controller system.

If using a single PC, the user must copy a set of files from the original Excalibur AD5400 or AD5500 directories to a temporary directory on the PC. If the files are to be transferred to another PC, they must be copied to a diskette or diskettes (depending on file size, more than a single diskette may be necessary).

Following is a table listing the files to be copied, and the directories in which they are found. Note: all of the files listed may not be loaded in the system. If not, copy the files that are loaded, and continue with the procedure.

Windows Directory

Windows

Excalibur ***

Excalibur/Data *****

File Name excalibr.ini

altmon.sdb

All files with extension “.map”

All files with extension “.icn” exmod001.sdb

iconad.sdb

iconinst.sdb

iconscrn.sdb

logsetup.sdb

mapsetup.sdb

operator.sdb

*** “Excalibur” is the default code directory in the Excalibur installation sequence.

***** “Excalibur/Data” is the default data directory in the Excalibur installation sequence.

1.

Using the diskette provided on a PC running

Windows 95, Windows 98, or Windows NT 4.0, install Excalibur 168. Note: When installing the software on Windows NT 4.0, it is also necessary for the user to install “hinstall.exe” (the HASP driver software). Prior to installing hinstall.exe, an error message may appear during the installation of

Excalibur 168. The user can click OK and ignore the message. If error messages continue to appear after the installation of the HASP driver, the user should contact AD Technical Support.

2.

In the Excalibur Program Group, run Excalibur

System Setup.

3.

Login with the default password (“UltraMax”).

4.

In the Excalibur System Setup Menus, select Set

Directory.

5.

Select the data directory (the default directory =

“Excalibur/Data”), and click OK.

6.

Exit the Excalibur System Setup Program.

On the PC running Excalibur 168, copy the files listed in the table above into the appropriate directories listed below.

Windows Directory File Name

Windows or Winnt

Excalibur ***

Excalibur / Data ***** excalibr.ini (replace installed file) altmon.sdb

All files with extension “.map”

All files with extension “.icn” exmod001.sdb

iconad.sdb

iconinst.sdb

iconscrn.sdb

logsetup.sdb

mapsetup.sdb

operator.sdb

*** “Excalibur” is the default code directory in the Excalibur installation sequence.

***** “Excalibur/Data” is the default data directory in the Excalibur installation sequence.

1.

Run “ad16to32.exe”

2.

Login using the password utilized in the previous

AD5400 or AD5500 program.

3.

Select “OK” to convert data from 16 to 32 bits.

4.

Exit “ad16to32.exe”

Note: After data conversion, users can login to

Excalibur 168 with the password used previously for

AD5400 or AD5500.

!"

Contact Technical Support at 1-800-442-2225

(or 914-624-7640). Fax: 914-624-7685

8000-1771-01, Rev A EXCALIBUR 168 MAP FILTER UTILITY INSTRUCTIONS