Lg LSRM205ST Microwave Installation Guide


Add to my manuals
35 Pages

advertisement

Lg LSRM205ST Microwave Installation Guide | Manualzz

Internal Use Only

Website http://biz.lgservice.com

MICROWAVE OVEN

SERVICE MANUAL

MODEL: LSRM205ST

CAUTION

BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.

April, 2010

Printed in Korea P/NO : MFL06272515

SAFETY PRECAUTIONS

This device is to be serviced only by properly qualified service personnel.

Consult the service manual for proper service procedures to assure continued safety operation and for precautions to be taken to avoid possible exposure to excessive microwave energy.

PRECAUTIONS TO BE OBSERVED BEFORE AND

DURING SERVICING TO AVOID POSSIBLE

EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

A) Do not operate or allow the oven to be operated with the door open.

B) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary; (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.

C) Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.

D) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.

E) A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner.

CAUTION

MICROWAVE RADIATION

DO NOT BECOME EXPOSED TO RADIATION FROM THE MICROWAVE GENERATOR

OR OTHER PARTS CONDUCTING MICROWAVE ENERGY.

CONTENTS

(Page)

SAFETY PRECAUTIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Inside front cover

SPECIFICATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1-1

CAUTIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2-1

INSTALLATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3-1

OPERATING INSTRUCTIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-1

FEATURES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-1

CONTROL PANEL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-1

OPERATING SEQUENCE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-2

SCHEMATIC DIAGRAM (II) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-4

CIRCUIT DESCRIPTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-5

SERVICE INFORMATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-1

TOOLS AND MEASURING INSTRUMENTS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-1

MICROWAVE LEAKAGE TEST - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-1

MEASUREMENT OF MICROWAVE POWER OUTPUT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-3

DISASSEMBLY AND ADJUSTMENT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-3

INTERLOCK CONTINUITY TEST - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-7

COMPONENT TEST PROCEDURE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-8

TROUBLE SHOOTING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5-11

EXPLODED VIEW - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6-1

REPLACEMENT PARTS LIST - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7-1

ITEM

Model

Power Requirement

Power Output

Microwave Frequency

Magnetron

Timer

Outside Dimensions

Cavity Dimensions

Net Weight

Shipping weight

Control Complement

SPECIFICATIONS

DESCRIPTION

LSRM205ST

120 V~ 60 Hz

1600 Watt (14.0 A)

Single phase, 3 wire grounded

1200 Watt full microwave power (IEC60705)

2450 MHz

2M246 - 050GF

0 ~ 9 min. 99 sec.

23 7 /

8

” (W) x 13 9 /

16

” (H) x 19 13 /

16

” (D)

16 11 /

16

” (W) x 11 1 /

4

” (H) x 18 1 /

16

” (D)

18Kg

20Kg

Touch Control System

Clock : 1:00 - 12:59

Microwave Power for Variable Cooking

Power level

HIGH --------------------------- Full power throughout the cooking time

9 (Saute)---------approx. 90% of Full power, 8 (Reheat)-------------approx. 80%

7 (Med.-High)---------------------approx. 70%, 6 (Medium)------------approx. 60%

5 (Med.-Low)---------------------approx. 50%, 4 (Defrost)-------------approx. 40%

3 (Low)-----------------------------approx. 30%, 2 (Simmer)------------approx. 20%

1 (Warm)---------------------------approx. 10%

Rating Label Location

Back side

Accessories

Owner's manual & cooking guide

Glass turntable

Rotating ring

This microwave oven is designed for household use only.

It is not recommended for commercial purposes.

1-1

CAUTIONS

Unlike other appliances, the microwave oven is high-voltage and high-current equipment.

Though it is free from danger in ordinary use, extreme care should be taken during repair.

• DO NOT operate on a 2-wire extension cord during repair and use.

• NEVER TOUCH any oven components or wiring during operation.

• BEFORE TOUCHING any parts of the oven, always remove the power plug from the outlet.

• For about 30 seconds after the oven stop, an electric charge remains in the high voltage capacitor. When replacing or checking, you must discharge the high voltage capacitor by shorting across the two terminals with an insulated screwdriver.

MICROWAVE RADIATION

Personnel should not be exposed to the microwave energy which may radiate from the magnetron or other microwave generating device if it is improperly used or connection.

All input and output microwave connections, waveguide, flange and gasket must be secure never operate the device without a microwave energy absorbing load attached.

Never look into an open waveguide or antenna while the device is energized.

• Proper operation of the microwave oven requires that the magnetron be assembled to the waveguide and cavity. Never operate the magnetron unless it is properly installed.

• Be sure that the magnetron gasket is properly installed around the dome of the tube whenever installing the magnetron.

ANTENNA

Gasket

COOLING FIN

FILAMENT

TERMINALS

MAGNETRON

MAGNETRON

CHASSIS GROUND

• Remove your watches whenever working close to or replacing the Magnetron.

• DO NOT touch any parts of the control panel circuit. A resulting static electric discharge may damage this

P.C.B.

• NEVER operate the oven with no load.

• NEVER injure the door seal and front plate of the oven cavity.

• NEVER put iron tools on the magnetron.

• NEVER put anything into the latch hole and the interlock switches area.

THE OVEN IS TO BE SERVICED ONLY

BY PROPERLY QUALIFIED SERVICE

PERSONNEL.

2-1

INSTALLATIONS

BEFORE YOU BEGIN, READ THE FOLLOWING INSTRUCTIONS COMPLETELY AND CAREFULLY.

INSTALLING

1. Empty the microwave oven and clean inside it with a soft, damp cloth. Check for damage such as misaligned door, damage around the door or dents inside the cavity or on the exterior.

2. Put the oven on a counter, table, or shelf that is strong enough to hold the oven and the food and utensils you put in it. (The control panel side of the oven is the heavy side. Use care when handling.)

3. Do not block the vent and the air intake openings.

Blocking vent or air intake openings can cause damage to the oven and poor cooking results.

Make sure the microwave oven legs are in place to ensure proper air flow.

4. The oven should not be installed in any area where heat and steam are generated, because they may damage the electronic or mechanical parts of the unit.

Do not install the oven next to a conventional surface unit or above a conventional wall oven.

5. Use microwave oven in an ambient temperature less than 104°F(40°C).

6. Place the microwave oven on a sturdy and flat surface at least 10 cm(4 inches) from the wall.

7. Place the microwave oven as far away as possible from TV, RADIO, COMPUTER, etc., to prevent interference.

GROUNDING INSTRUCTIONS

For personal safety,this appliance must be fully grounded at all times.

In the event of an electrical short circuit, grounding reduces the risk of electrical shock.

The plug must be plugged into an outlet that is properly installed and grounded.

WARNING

Improper use of the grounding plug can result in a risk of electric shock.

Do not, under any circumstances, cut or remove the third ground prong from the power cord plug.

PREFERRED METHOD

INSURE PROPER GROUND

EXISTS BEFORE USE

TEMPORARY METHOD

(ADAPTER PLUGS NOT

PERMITTED IN CANADA)

ALIGN LARGE

PRONGS/SLOTS

ENSURE PROPER GROUND

AND FIRM CONNECTION

BEFORE USE

3-1

FEATURES

OPERATING INSTRUCTIONS

CONTROL PANEL

1

11

12

14

16

17

2

3

4

7

8

5

6

9

10

13

15

18

4-1

1. DISPLAY :

The display includes a clock and indicators that tell you time of day, cooking time settings, and cooking functions selected.

2. SENSOR TOUCH :

This pad allows you to cook most of your favorite foods without having to select cooking times and power levels.

3. AUTO COOK :

Touch this pad to select programming food items.

4. CUSTOMSET:

Touch this pad to select sound(on/off), clock(on/off), scroll speed(slow, normal, fast) and unit(lbs./kg.).

5. LESS :

Each time you touch this pad, you subtract 10 seconds from the cooking time.

6. MORE :

Each time you touch this pad, you add 10 seconds to the cooking time.

7. EXPRESS DEFROST :

Touch this pad to thaw only 1lb of food very quickly.

8. AUTO DEFROST :

Thispadis anaccurate defrosting method for meat,poultryandfishupto6.0lbsor 4.0 kgs.

9. SOFTEN :

Touch this pad to soften butter,ice cream, cream cheese, or frozen juice.

10. MELT :

TTouch this pads to melt butter,margarine, chocolate,cheese,or mashmallows.

11. NUMBER PADS :

Touch number pads to enter cooking time, power level, quantities, or weights.

12. TIME COOK :

Touch this pad to set a cooking time.

13. POWER LEVEL :

Touch this pad to set a cooking power.

14. KITCHEN TIMER :

Touch this pad to use your microwave oven as a kitchen timer.

15. EZ-ON :

Touch this pad to cook at 100% cook power for 30 seconds up to 3 minutes 30 seconds; after 3 minutes 30 seconds, every touch will add 1 minute up to 99 min 59 seconds.

16. CLOCK :

Touch this pad to enter the time of day.

17. START/ENTE R :

This feature allows oven to begin functioning.

18. STOP/CLEAR :

Touch this pad to stop the oven or clear entries.

OPERATING SEQUENCE

The following is a description of component functions during oven operation.

1. CANCEL FUNCTION

cancel an entry or a function currently in use.

The display will return either to the last item entered or to the clock.

2. Ez On

STOP/CLEAR Ez On

3. SENSOR TOUCH

STOP/CLEAR POPCORN NUMBER OF TABLE

NOTE: • Heat only 1 package at a time

• Then the oven will start automatically.

4. TIME COOKING

STOP/CLEAR

COOK

TIME

NUMBER POWER

NUMBER START

5.MULTI-STAGE COOKING

You can program your oven to switch from one power level to another for up to 3 stages.

To set a 2-stage cook cycle.

1ST STAGE

STOP/CLEAR COOK TIME NUMBER POWER LEVEL

NUMBER

2ND STAGE

COOK TIME

NUMBER

NUMBER

START

POWER LEVEL

6. AUTO DEFROST COOKING

STOP/CLEAR

AUTO

DEFROST

NUMBER

NUMBER OF

WEIGHT

START

4-2

7. CHILD LOCK

This oven has a CHILD LOCK feature

TO SET CHILD LOCK

• Touch and hold pad

LOCKED

appears on the display.

TO CANCEL CHILD LOCK

• Touch and hold pad

LOCKED

disappears.

8. MORE /LESS

The cook time is adjustable by MORE pad or LESS pad

STOP/CLEAR COOKING MORE

STOP/CLEAR COOKING LESS

9. QUICK DEFROST

STOP/CLEAR QUICK-DEFROST

10. KITCHEN TIMER

STOP/CLEAR

KITCHEN

TIMER

NUMBER START

11. MELT

STOP/CLEAR MELT NUMBER OF TABLE

NOTE:Then the oven will start automatically.

12. SOFTEN

STOP/CLEAR SOFTEN NUMBER OF TABLE

NOTE:Then the oven will start automatically.

13. CUSTOM SET

STOP/CLEAR

CUSTOM

SET

14. EXPRESS DEFROST

STOP/CLEAR EXPRESS DEFROST

NUMBER OF TABLE

SCHEMATIC DIAGRAM

4-3

CIRCUIT DESCRIPTION

GENERAL DETAILS

• The low voltage transformer supplies the necessary voltage to the micom controller when power cord is plugged in.

• When the door is closed, the primary switch is ON, the secondary switch is ON, and the monitor switch opens

(contact COM and NO).

WHEN SELECTING COOKING POWER

LEVEL AND TIME

• The micom controller memorizes the function you set.

• The time you set appears in the display window.

• Each indicator light turns on to indicate that the stage has been set.

WHEN TOUCHING THE START PAD

• The coil of the relay is energized by the micom controller.

• Power input is supplied to the high voltage transformer through the fuse to the primary switch and relay 2.

• Turntable rotates.

FUSE

PRIMARY

SWITCH

L

N

MONITOR

SWITCH

H.V.

TRANS-

FORMER

RELAY 2

SECONDARY

SWITCH

MICOM CONTROLLER

• The fan motor rotates and cools the magnetron by blowing the air (coming from the intake on the baseplate).

• The air is also directed into the oven to exhaust the vapor in the oven through the upper plate.

• Cooking time starts counting down.

• 3.3 volts AC is generated from the filament winding of the high voltage transformer. This 3.2 volts is applied to the magnetron to heat the magnetron filament through two noise-preventing choke coils.

• A high voltage of approximately 2100 volts AC is generated in the secondary of the high voltage transformer which is increased by the action of the high voltage diode and charging of the high voltage capacitor.

• The negative 4,000 Volts DC is applied to the filament of the magnetron.

WHEN THE OVEN IS SET AT ANY LEVEL

EXCEPT MAXIMUM.

• The micom controller controls the ON-OFF time of relay 2 by the applied signal to vary the average output power of microwave oven as POWER LEVEL.

(refer to page 1-1)

• One complete cycle of relay 2 is 22 seconds.

WHEN THE DOOR IS OPENED DURING

COOKING

• Both the primary switch and relay 2 are cut off primary winding voltage of the high voltage transformer.

• ON-OFF of relay 2 is coupled electrically with opening and closing of the secondary switch.

• When the door is opened, the secondary switch is opened and when the door is closed, the secondary switch is closed.

• The cooking time stops counting down.

• Relay stops functioning.

• As the door is opened, if the contact of primary switch and relay 2 and/or secondary switch fails to open, the fuse opens due to the large current surge caused by the monitor switch activation, which in turn stops magnetron oscillation.

FUSE

PRIMARY

SWITCH

L

N

MONITOR

SWITCH

H.V.

TRANS-

FORMER

RELAY 2

MICOM CONTROLLER

SECONDARY

SWITCH

4-4

SERVICE INFORMATION

TOOLS AND MEASURING INSTRUMENTS

NECESSARY TOOLS

Tools normally used for TV servicing are sufficient.

Standard tools are listed below.

• Diagonal pliers

• Long nose pliers

• Phillips screwdriver

• Flat blade screwdriver

• Wrench (size 5mm)

• Nutdriver (size 5mm)

• Adjustable wrench

• Soldering iron

• Solder

• Vinyl insulation tape

• Polishing cloth

NECESSARY MEASURING INSTRUMENTS

• TESTER (VOLTS-DC, AC, Ohmmeter)

• Microwave survey meter

- Holaday HI-1500

HI-1501

- Narda 8100

8200

• Inch scale

• 600 cc non conductive material beaker (glass or plastic), inside diameter: approx. 8.5 cm (3

1

/2 in.)

• Cylindrical and made of borosilicate glass vessel.

max. thickness: 3 mm outside diameter: approx. 190mm height: approx. 90mm

• Glass thermometer: 100°C or 212°F (1 deg scale)

MICROWAVE LEAKAGE TEST

CAUTIONS

• Be sure to check microwave leakage prior to servicing the oven if the oven is operative prior to servicing.

• The service personnel should inform the manufacture, importer, or assembler of any certified oven unit found to have a microwave emission level in excess of 5 mW/cm

2

and should repair any unit found to have excessive emission levels at no cost to the owner and should ascertain the cause of the excessive leakage. The service personnel should instruct the owner not to use the unit until the oven has been brought into compliance.

• If the oven operates with the door open, the service personnel should:

- Tell the user not to operate the oven.

- Contact the manufacturer.

• The service personnel should check all surface and vent openings for microwave leakage.

• Check for microwave leakage after every servicing. The power density of the microwave radiation leakage emitted by the microwave oven should not exceed

4 mW/cm

2

. Always start measuring of an unknown field to assure safety for operating personnel from radiation leakage.

MEASURING MICROWAVE ENERGY

LEAKAGE

• Pour 275±15cc of 20±5°C(68±9°F) water in a beaker which is graduated to 600 cc, and place the beaker on the center of the turntable.

• Set the energy leakage monitor to 2,450 MHz and use it following the manufacturer's recommended test procedure to assure correct result.

• When measuring the leakage, always use the 2- inch

(5 cm) spacer supplied with the probe.

• Operate the oven at its maximum output.

• Measure the microwave radiation using and electromagnetic radiation monitor by holding the probe perpendicular to the surface being measured

Move probe along shaded area

Probe scanning speed

Less than 2.5 cm/sec

(1 in/sec)

5-1

MEASUREMENT WITH OUTER CASE

REMOVED

• When you replace the magnetron, measure for microwave energy leakage before the outer case is installed and after all necessary components are replaced or adjusted.

Special care should be taken in measuring the following parts. (Circled area of Fig. below)

- Around the magnetron

- The waveguide

WARNING : AVOID CONTACTING ANY

HIGH VOLTAGE PARTS

MEASUREMENT WITH A FULLY

ASSEMBLED OVEN

• After all components, including the outer case, are fully assembled, measure for microwave energy leakage around the door viewing window, the exhaust opening, and air inlet openings.

• Microwave energy leakage must not exceed the values prescribed below.

NOTE

: Leakage with the outer case removedless than

5 mW/cm.sq. Leakage for a fully assembled oven (Before the latch switch (primary) is interrupted) with the door in a slightly opened position-less than 2 mW/cm.sq.

NOTES WHEN MEASURING

• Do not exceed meter full scale deflection.

• The test probe must be removed no faster than

1 inch/sec (2.5 cm/sec) along the shaded area, otherwise a false reading may result.

• The test probe must be held with the grip portion of the handle.

A false reading may result if the operator's hand is befween the handle and the probe.

• When testing near a corner of the door, keep the probe perpendicular to the surface making sure the probe horizontally along the oven surface.Hold vertically when testing the top and bottom,and horizontally along.

RECORD KEEPING AND NOTIFICATION

AFTER MEASUREMENT

• After adjustment and repair of any microwave energy interruption or microwave energy blocking device, record the measured values for future reference. Also enter the information on the service invoice.

• The microwave energy leakage should not be more than 4 mW/cm.sq. after determining that all parts are in good condition, functioning properly and genuine replacement parts which are listed in this manual have been used.

• At least once a year, have the electromagnetic energy leakage monitor checked for calibration by its manufacturer.

SPECIAL TIP

• This oven used the button head screws.

Button Head

(Torx style 2)

• When you remove the screws, use the tamper-resistant Torx driver having a pin-in-head.

5-2

MEASUREMENT OF MICROWAVE POWER OUTPUT

• Microwave power output measurement is made with the microwave oven supplied at its rated voltage and operated at its maximum microwave power setting with a load of (1000±5) g of potable water.

• The water is contained in a cylindrical borosilicate glass vessel having a maximum material thickness of 3 mm and an outside diameter of approximately 190mm.

• The oven and the empty vessel are at ambient temperature prior to the start of the test.

• The initial temperature (T1) of the water is (10±2)°C. It is measured immediately before the water is added to the vessel. After addition of the water to the vessel, the load is immediately placed on the center of the turntable which is in thd lowest position and the microwave power switched on.

• The time T for the temperature of the water to rise by a value

T of (10±2)°K is measured, where T is the time in seconds and

T is the temperature rise. The initial and final water temperatures are selected so that the maximum difference between the final water temperature and the ambient temperature is 5°K.

• The microwave power output P in watts is calculated from the following formula :

4187 x (

T) + 0.55 X (T

2

- T

0

) X M

P =

T

• T

2

: Temperature after heating

• T

0

: Temperature of bowl

• M: Weight of bowl is measured while the microwave generator is operating at full power. Magnetron filament heat-up time is not included. (about 3 sec)

• The water is stirred to equalize temperature throughout the vessel, prior to measuring the final water temperature.

• Stirring devices and measuring instruments are selected in order to minimize addition or removal of heat.

WATER LOAD

TURNTABLE

DISASSEMBLY AND ADJUSTMENT

A. OUTER CASE REMOVAL

1) Disconnect the power supply cord from the outlet.

2) Remove the screws from the rear of the case.

The outer case must be moved backward to be lifted off.

B. POWER SUPPLY CORD

1) Remove the outer case.

2) Disconnect two terminals and remove one screw of the ground terminal.

C.CONTROL PANEL ASSEMBLY

1) Open the door.

2) Disconnect the lead wire from RELAY (RY2) of the

PCB SUB ASSEMBLY.

3) Disconnect the leadwire from connector (CN1) of the

PCB SUB ASSEMBLY.

4) Remove screw which hold the controller assembly to the cavity.

5) Lift up and pull out control panel assembly carefully from the cavity.

CAUTION: DISCHARGE THE HIGH VOLTAGE

CAPACITOR BEFORE SERVICING

(refer to page 2-1)

5-3

Remove the screw ground screw

Lift up and pull out control panel securing screw

D. PCB ASSEMBLY REMOVAL

1) Remove the control panel assembly from the cavity. (Refer to control panel assembly removal on previous page.)

2) Remove screws which hold the PCB SUB ASS’Y to the control panel.

3) Disconnect the flat cable from the PCB SUB

ASS’Y and take off the PCB SUB ASS’Y

Remove choke cover

Remove door Assembly

E. DOOR MAIN ASSEMBLY / REMOVAL

1) Open the door.

2) Remove the choke cover very carefully with a flat-blade screwdriver.

CAUTION: Be careful not to damage door seal plate by screwdriver.

3) Lift up and push the door.

NOTE:

1. After replacing the door, be sure to check that the primary switch, monitor switch, and secondary switch operate normally.

2. After replacing the door, check for microwave energy leakage with a survey meter. Microwave energy must be below the limit of 4 mW/cm

2

. (with a 275 ml water load)

3. When mounting the door assembly to the oven assembly, be sure to adjust the door assembly parallel to the chassis. Also adjust so the door has no play between the inner door surface and oven frame assembly. If the door assembly is not mounted properly, microwaves may leak from the clearance between the door and the oven.

5-4

Spacer

F. AIR DUCT ASSEMBLY / REMOVAL

1) Disconnect the leadwire from lamp.

2) Remove the mounting screw to the magnetron.

G. MAGNETRON REMOVAL

1) Disconnect the leadwire from themagnetron.

2) Carefully remove the mounting screws holding the magnetron to the waveguide.

3) Remove the magnetron ASS’Y until the tube is clear from the waveguide.

NOTE:

1. When removing the magnetron, make sure its dome does not hit any adjacent parts, or it may be damaged.

2. When replacing the magnetron, be sure to install the magnetron gasket in the correct position and be sure that the gasket is in good condition.

3. After replacing the magnetron, check for microwave leakage with a survey meter around the magnetron. Microwave energy must be below the limit of 5 mW/cm 2 . (With a 275 ml. water load).

Make sure that gasket is rigidly attached to the magnetron.

To prevent microwave leakage, tighten the mounting screws properly, making sure there is no gap between the waveguide and the magnetron.

G. REMOVING SENSOR

1) Disconnect the leadwire from PCB Assembly.

2) Remove a screw securing the sensor duct.

Alr duct

Magnetron

Waveguide

Dome

Waveguide

Bracket

Magnetron

Gasket

Magnetron

5-5

H. REMOVING THE TURNTABLE MOTOR

1) Remove the turntable and rotating ring.

2) Lay the unit down on its back.

3) Remove the turntable motor cover.

The turntable base cover is easily removed by pinching the eight parts with a wire cutting.

4) Disconnect the leadwire from the turntable motor terminals.

5) Remove the screw securing the turntable motor to the oven cavity ASS’Y

6) After repairing the motor, rotate the removed turntable motor cover.

7) Fit the turntable motor cover’s projecting part to the base plate slit.

8) The taptite screw shall be used when a turntable motor cover is secured with a screw.

NOTE:

1. Remove the wire lead from the turntable motor VERY

CAREFULLY.

2. Be sure to grasp the connector, not the wires, when removing.

I. HIGH VOLTAGE TRANSFORMER

REMOVAL

1) Discharge the high voltage capacitor.

2) Disconnect the leadwire from magnetron, high voltage transformer, and capacitor.

3) Remove the screw holding the high voltage transformer to the baseplate.

J. FAN MOTOR ASSEMBLY REMOVAL

1) Discharge the high voltage capacitor.

2) Disconnect the leadwire from fan motor and high voltage capacitor.

3) Remove the two screws holding the the suction guide

ASS’Y to the oven cavity and remove the high voltage diode earth screw.

4) Remove the two screws holding the fan motor ASS’Y to the suction guide ASS’Y.

K. HIGH VOLTAGE CAPACITOR AND

DIODE REMOVAL

1) Discharge the high voltage capacitor.

2) Disconnect the leadwire from fan motor and high voltage capacitor.

3) Remove the screw holding the suction guide ASS’Y to the oven cavity and remove the high voltage diode earth screw.

4) Remove the screw holding the high voltage capacitor bracket.

Fan Motor

ASS'Y

Suction

Guide

H.V.

Transformer

H.V.

Diode

Taptite Screw

Wire Leads

Turntable Motor

5-6

L. INTERLOCK SYSTEM

1) INTERLOCK MECHANISM

The door lock mechanism is a device which has been specially designed to eliminate completely microwave activity when the door is opened during cooking and thus to prevent the danger resulting from the microwave leakage.

ADJUSTMENT

DIRECTION

PRIMARY

SWITCH

MONITOR

SWITCH

SECONDARY

SWITCH

2) MOUNTING OF THE PRIMARY/MONITOR/

SECONDARY SWITCHES TO THE LATCH

BOARD

3) INSTALLATION AND ADJUSTMENT OF THE

LATCH BOARD TO THE OVEN ASSEMBLY

• Mount the latch board to the oven assembly.

• Adjust the latch board in the arrow direction so that oven door will not have any play in it when the door is closed.

• Tighten the mounting screw.

• Check for play in the door by pushing the door release button. Door movement should be less than 0.5 mm. (1/64 inch)

Don't push the door release button while making this adjustment. Make sure that the latch moves smoothly after adjustment are completed and that the screws are tight. Make sure the primary, monitor, and secondary switches operate properly by following the continuity test procedure.

5-7

INTERLOCK CONTINUITY TEST

WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION

EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.

TYPE NO.SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH

TYPE NO.SZM-V 16-FA-62 OR VP-532A-OF OR V-5220Q FOR MONITOR SWITCH

TYPE NO.SZM-V 16-FA-63 OR VP-533A-OF OR V-5230Q FOR SECONDARY SWITCH

A. PRIMARY INTERLOCK SWITCH TEST

When the door release button is depressed slowly with the door closed, an audible

click

should be heard at the same time or successively at intervals. When the button is released slowly, the latches should activate the switches with an audible

click.

If the latches do not activate the switches when the door is closed, the switches should be a adjusted in accordance with the adjustment procedure. Disconnect the wire lead from the primary switch. Connect the ohmmeter leads to the common (COM) and normally open (NO) terminal of the switch. The meter should indicate an open circuit in the door open condition.

When the door is closed, the meter should indicate a closed circuit.

When the primary switch operation is abnormal, make the necessary adjustment or replace the switch only with the same type of switch.

SWITCHES

(Wire leads removed)

Check for continuity of the switch with an Ohm-meter

Primary

Switch

COM

NO

B. SECONDARY INTERLOCK SWITCH TEST

Disconnect the wire lead from the secondary switch.

Connect the ohmmeter leads to the common

(COM) and normally open (NO) terminals of the switch. The meter should indicate a open circuit in the door open condition. When the door is closed, meter should indicate an closed circuit. When the secondary switch operation is abnormal, make the necessary adjustment or replace the switch only with the same type of switch.

C. MONITOR SWITCH TEST

Disconnect the wire lead from the monitor switch.

Connect the ohmmeter leads to the common

(COM) and normally closed (NC) terminals of the switch. The meter should indicate closed circuit in the door open condition. When the door is closed, meter should indicate an open circuit. When the monitor switch operation is abnormal, replace with the same type of switch.

NOTE: After repairing the door or the interlock system, it is necessary to do this continuity test before operating the oven.

Door open

RESULTS

Door closed

Monitor

Switch

COM

NC

Secondary

Switch

COM

NO

NOTE : After checking for the continuity of switches, make sure that they are connected correctly.

5-8

COMPONENT TEST PROCEDURE

CAUTIONS

1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE

OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH

VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE

HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)

2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER

OF WATER IN CONTAINER) IN THE OVEN.

HIGH VOLTAGE

TRANSFORMER

(Wire leads removed)

FILAMENT

WINDING

MAGNETRON

(Wire leads removed)

PRIMARY

TERMINAL

1. Measure the resistance.

(Ohm-meter scale: Rx1 and Rx100)

• Primary winding

• Secondary winding

• Filament winding

2. Measure the resistance.

(Ohm-meter scale: Rx1000)

• Primary winding to ground

• Filament winding to ground

1. Measure the resistance.

(Ohm-meter scale: Rx1)

• Filament terminal

2. Measure the resistance.

(Ohm-meter scale: Rx1000)

• Filament to chassis

Approx.: 0.2 ~ 0.4 ohm

Approx.: 70 ~ 100 ohm

Less than: 1 ohm

Normal: Infinite

Normal: Infinite

Normal: Less than 1 ohm

Normal: Infinite

5-9

HIGH VOLTAGE

CAPACITOR

Antenna

Gasket

Chassis

Filament

NOTE: When testing the magnetron, be sure to install the magnetron gasket in the correct position and be sure that the gasket is in good condition.

Measure the resistance.

(Ohm-meter scale: Rx1000)

• Terminal to terminal.

Normal: Momentarily indicates several ohms, and then gradually returns to infinite.

Measure the resistance.

(Ohm-meter scale: Rx1000)

• Terminal to case.

Normal: Infinite.

HIGH VOLTAGE

DIODE

Measure the continuity (Forward).

(Ohm-meter scale: Rx10000)

Normal: Continuity.

Abnormal: Infinite.

NOTE :

Some inexpensive meters may indicate infinite resistance in both direction.

Measure the continuity (Reverse).

(Ohm-meter scale: Rx10000)

Normal: Infinite.

Abnormal: Continuity.

5-10

COMPONENTS

RELAY 2

TEST PROCEDURE

Check for continuity of relay 2 with an ohm-meter.

(Remove wire leads from relay 2 and operate the unit.)

RESULTS

POWER

LEVEL

7

8

5

6

3

4

1

2

9

10

4 sec

6 sec

8 sec

10 sec

12 sec

14 sec

16 sec

18 sec

20 sec

22 sec

18 sec

16 sec

14 sec

12 sec

10 sec

8 sec

6 sec

4 sec

2 sec

0 sec

FAN MOTOR

(Wire leads removed)

Measure the resistance.

(Ohm-meter scale: R x 1)

Normal:

A:Approx. 85 ~ 100 ohm.

B:Approx. 10 ~ 25 ohm.

Abnormal: Infinite or several ohm.

TURNTABLE

MOTOR

(Wire leads removed)

Measure the resistance.

(Ohm-meter scale: R x 1)

Normal: Approx. 100 ~ 150 ohm

Abnormal: Infinite or several ohm.

NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS

SERVICED FOR ANY REASON.

• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.

• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE

CONNECTOR, NOT THE WIRES.

5-11

TROUBLE SHOOTING

WHEN YOU GET A COMPLAINT FROM YOUR CUSTOMER, EVALUATE THE COMPLAINT CAREFULLY. IF

THE FOLLOWING SYMPTOMS APPLY, PLEASE INSTRUCT THE CUSTOMER IN THE PROPER USE OF THE

MICROWAVE OVEN. THIS CAN ELIMINATE AN UNNECESSARY SERVICE CALL.

CAUTIONS

1. Check grounding before checking for trouble.

2. Be careful of the high voltage circuit.

3. Discharge the high voltage capacitor. (See page 2-1)

4. When checking the continuity of the switches or of the high voltage transformer, disconnect one lead wire from these parts and then check continuity with the AC plug removed. To do otherwise may result in a false reading or damage to your meter.

5. Do not touch any part of the circuit on the PCB since static electric discharge may damage this control panel.

Always touch yourself to ground while working on this panel to discharge any static charge built up in your body. (Micom model only)

CONDITION

Microwave oven does not work.

Output power is too low.

CAUSE

Inserting many plugs into one outlet and using them at the same time.

(blown fuse or breaker)

Microwave oven plug is not inserted tightly.

Low AC input voltage.

REMEDY

Avoid using other electrical appliances when you use the microwave oven.

Sparks occur.

Uneven cooking.

Food temperature is too low.

Using metallic ware and allowing it to touch the oven wall.

Ceramic ware trimmed in gold or silver powder is used.

Inconsistent intensity of microwave by their characteristics.

Insert microwave oven plug securely.

Use the microwave oven at adequate line voltage.

This may not be a defect.

It is possible that the food should be cooked for a longer time period.

Do not use metallic ware for cooking except where noted in the cooking guide.

Do not use any type of cookware with metallic trimming.

1. Use plastic wrap or lid.

2. Stir once or twice while cooking soup, cocoa or milk, etc.

5-12

(TROUBLE 1) The following visual conditions indicate a probable defective control circuit.

1. Incomplete segments.

• Segment missing.

• Partial segment missing.

• Digit flickering (NOTE: Slight flickering is normal.)

2. Colon does not turn on or blink.

3. A distinct change in the brightness of one or more numbers in display.

4. One or more digits in the display are not lighting.

5. Display indicates a number different from one touched,for example,key in

5

and

3

appears in the display.

6. Specific numbers (for example 7 or 9) will not display when key pad is touched.

7. Display does not count down with time blinking or up with clock operation.

8. Display obviously jumps in time while counting down.

9. Display counts down too fast while cooking.

10. Each indicator light does not turn on after setting cooking cycle.

11. Display time of day does not reappear when cooking is finished.

CONDITION

1. No input can be programmed.

2. Some inputs cannot be programmed.

3. Display shows a number or figure different from one touched.

4. Random programming when touching other pads.

5. Display is fixed at some figure and can not accept any input.

CHECK

Check the connection between membrane key assembly and

PCB assembly.

Replace key membrane assembly and check operation.

RESULT

Continuity.

No continuity.

Everything works as specified.

Still have trouble.

CAUSE

Defective PCB assembly.

Loose connection.

Defective key membrane assembly.

Defective PCB assembly.

REMEDY

Replace PCB assembly.

Connect them tightly.

Replace key membrane assembly.

Replace PCB assembly.

5-13

(TROUBLE 2) Oven does not operate at all, Display window does not display any figures, and no input is accepted.

CONDITION RESULT

1. Fuse blows.

CHECK

Check continuity of monitor switch (with door closed).

Replace fuse

Continuity.

No continuity.

CAUSE

Malfunction of the monitor switch.

REMEDY

Replace fuse, primary, monitor, secondary switches, and

RELAY(RY2) of

P.C.B Assembly.

Check continuity of primary switch (with door opened)

Check continuity of secondary switch (with door opened).

Disconnect one side of the wire lead connected from transformer to the high voltage capacitor and operate the unit.

Continuity.

No continuity.

Continuity.

No continuity.

Normal.

Fuse blows again

Shorted contact at the primary switch.

Malfunction of secondary switch.

Defective high voltage capacitor.

Defective high voltage transformer.

Replace fuse, primary, monitor, secondary switches, and

RELAY(RY2) of

P.C.B Assembly.

Replace fuse, primary, monitor, secondary switches, and

RELAY(RY2) of

P.C.B Assembly.

Replace high voltage capacitor.

Replace high voltage transformer.

NOTE : All these switches must be replaced at the same time. Refer to page 5-7, 5-8

2. Fuse does not blow.

Defective thermostat.

Replace thermostat.

Check continuity of thermostat.

No continuity.

Continuity.

Check continuity of power supply cord.

No continuity.

5-14

Defective power supply cord.

Replace power supply cord.

(TROUBLE 3) Display shows all figures set, but oven does not start cooking while desired program times are set and START pad is touched.

CONDITION

1.Setting time does not count down when touching START pad.

CHECK

Check continuity of secondary switch (with door closed).

RESULT

No continuity.

Continuity.

CAUSE

Defective secondary switch.

REMEDY

Replace secondary switch.

2. Fan motor or oven lamp do not turn on.

Check the connection between

CN1 connector and PCB assembly.

Check fan motor.

Check oven lamp.

Continuity

No continuity

Abnormal

Abnormal

Normal

Defective PCB assembly.

Loose connection.

Defective fan motor.

Defective oven lamp.

Replace PCB assembly.

Connection then tightly.

Replace fan motor.

Defective oven lamp.

(TROUBLE 4) Oven seems to be operation but little heat is produced in oven load.

CONDITION CHECK

Output is low.

Check the power source voltage.

RESULT

Lower than 90% of rating voltage.

Normal.

Abnormal.

CAUSE

Decrease in power source voltage with load.

Defective PCB assembly.

REMEDY

Suggest customer contact local electric power utility co. or qualified electrician.

Replace PCB assembly.

Disconnect the wire leads from relay 2 and check on and off time with multitester.

Normal.

Measure the output power.

Abnormal.

Defective magnetron.

Replace magnetron.

NOTE: Simple test of power output-conducted by heating one liter water for one min. if available.

Minimum 8.5

o C temperature rise is normal condition.

5-15

(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.

(Display operates properly)

CHECK RESULT CONDITION

No microwave oscillation.

CAUSE

Defective PCB assembly

REMEDY

Replace PCB assembly

Disconnect the wire leads from relay 2 and check continuity of relay2.

(Operate the unit)

No continuity.

Continuity.

Check high voltage transformer

Abnormal normal

Defective high voltage transformer.

Replace high voltage transformer.

Check high voltage capacitor.

Abnormal

Defective high voltage capacitor.

Replace high voltage capacitor.

normal

Check high voltage diode.

Abnormal

Defective high voltage diode.

Replace high voltage diode.

normal

Check

Magnetron.

Abnormal

Defective magnetron.

Replace magnetron.

NOTE: • Make sure the wire leads correct position.

• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.

• When removing the magnetron, be sure to install the magnetron gasket in the correct position and in good condition.

Output is full power when you set lower power level.

Disconnect the wire leads from relay 2 and check continuity relay 2.

(Operate the unit)

Abnormal.

Defective PCB assembly

Replace PCB assembly

5-16

#EV#

INTRODUCTION

MODEL:

EXPLODED VIEW

SENSOR PARTS

OVEN CAVITY PARTS

INTERIOR PARTS

DOOR PARTS

BASE PLATE PARTS

LATCH BOARD PARTS

CONTROL PANEL PARTS

MFL552

MAY000

-6-1-

#EV#

DOOR PARTS

13581A

13551A

13213A

13552A

13536A

14970A

14026A

-6-2-

#EV#

CONTROLLER PARTS

24781M

23551A

23550D

268711

WTP018

24510L

23551B

24970A

-6-3-

#EV#

OVEN CAVITY PARTS

33112U

WSZ185

Button Head

(Torx style 2)

33052A

36549S

WTP013

33390G

35889A

-6-4-

WTT020

#EV#

LATCH BOARD PARTS

43500A

43501A

WSZ 085

56912B

466001

WTT028

55262A

466003

466001

-6-5-

#EV#

INTERIOR PARTS

568771

948501

WSZ002

56411A

56930V

34930W

WTT028

50 FZZA

54974S

56201A

56549F

WEB001

55900A

WTT037

WSZ 002

56324A

35012A

WSZ 002

WTT028

50CZZH

54810C

WEB001

56851D

-6-6-

#EV#

BASE PLATE PARTS

63302L

63303L

WTT021

65006B

56170D

63303R

63302R

65006B

WSZ002

WTT028

-6-7-

#EV#

SENSOR PARTS

WTP004

WSZ002

56501A

54974T

-6-8-