3Com 1000BASE-T Technical information
Reklāma
Reklāma
Introduction
This guide covers installation, removal and technical information for the
■
1000BASE-SX SFP Transceiver (3CSFP91)
■
■
■
1000BASE-LX SFP Transceiver (3CSFP92)
1000BASE-T SFP Transceiver (3CSFP93)
1000BASE-LH70 SFP Transceiver (3CSFP97)
Each transceiver, when installed into a 3Com Switch, provides a high-speed Gigabit Ethernet connection. They can be installed and removed with your system powered up.
SFP Transceiver
Installation Guide
1000BASE-SX (3CSFP91)
1000BASE-LX (3CSFP92)
1000BASE-T (3CSFP93)
1000BASE-LH70 (3CSFP97)
Copyright © 2003, 3Com Corporation. All rights reserved.
No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of
3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms, or conditions of merchantability, satisfactory quality, and fitness for a particular purpose.
3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.
3Com registered trademarks are registered in the United
States and may or may not be registered in other countries. 3Com and the 3Com logo are registered trademarks of 3Com Corporation.
All other company and product names may be trademarks of the respective companies with which they are associated.
Installation and Removal
Safety Precautions
Be sure you follow all safety precautions when you install or replace an SFP Transceiver. To avoid electric shocks and burns to yourself and damage to the equipment, read and follow these warnings:
WARNING : When the system is on:
■
■
Never insert a metal object such as a screwdriver or a finger with jewelry into open module slots
Do not touch any connections inside the chassis with your hands or fingers.
WARNING : Fiber Optic ports - Optical Safety.
Never look at the transmit laser while it is poweredup. Never look directly at the fiber TX port and fiber cable ends when they are powered-up.
WARNING : Use of controls or adjustments of performance or procedures other than those specified herein may result in hazardous laser emissions.
WARNING : RJ-45 Ports. These are shielded RJ-45 data sockets. They cannot be used as standard traditional telephone sockets, or to connect the unit to a traditional PBX or public telephone network.
Only connect RJ-45 data connectors, network telephony systems, or network telephones to these sockets.
Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets.
AVERTISSEMENT : Quand le systeme est allumé:
■
■
Ne jamais introdure d'objet métallique, tel qu' un tourne vis ou meme votre doight si vous portez un bijou dans le reserve au module.
Ne touchez aucun engrenage à l' interieur du chasis avec le doight ou la main.
AVERTISSEMENT : Ports pour fibres optiques – sécurité sur le plan optique.
Part No. DIASFP91-AAA03
Published October 2003
Ne regardez jamais le laser tant qu'il est sous tension.
Ne regardez jamais directement le port TX
(Transmission) à fibres optiques et les embouts de câbles à fibres optiques tant qu'ils sont sous tension.
AVERTISSEMENT : L'utilisation de contrôles, de réglages de performances ou de procédures autres que ceux qui sont spécifiés au sein du présent document risquent d'entraîner l'exposition à des rayonnements laser dangereux.
AVERTISSEMENT : Points d’accès RJ-45. Ceux-ci sont protégés par des prises de données. Ils ne peuvent pas être utilisés comme prises de téléphone conventionnelles standard, ni pour la connection de l’unité à un réseau téléphonique central privé ou public. Raccorder seulement connecteurs de données RJ-45, systèmes de réseaux de téléphonie ou téléphones de réseaux à ces prises.
Il est possible de raccorder des câbles protégés ou non protégés avec des jacks protégés ou non protégés à ces prises de données.
VORSICHT : Wenn das Betriebssystem angeschaltet ist:
■
■
Führen Sie niemals einen Metallgegenstand wie z.B. einen Schraubenzieher oder einen beringten
Finger in den offenen Modulschlitz ein.
Berühren Sie keine Verbindungen innerhalb des
Gehäuses mit Ihren Händen oder Fingern.
VORSICHT : Faseroptikanschlüsse – Optische
Sicherheit.
Niemals ein Übertragungslaser betrachten, während dieses eingeschaltet ist. Niemals direkt auf den Faser-
TX-Anschluß und auf die Faserkabelenden schauen, während diese eingeschaltet sind.
VORSICHT : Die Verwendung von Steuerelementen oder die Anpassung von Leistungen und Verfahren in anderer als der hierin genannten Weise kann zu gefährlichen Laseremissionen führen.
VORSICHT : RJ-45-Porte. Diese Porte sind geschützte
Datensteckdosen. Sie dürfen weder wie normale traditionelle Telefonsteckdosen noch für die
Verbindung der Einheit mit einem traditionellem privatem oder öffentlichem Telefonnetzwerk gebraucht werden. Nur RJ-45-Datenanscluße,
Telefonnetzsysteme or Netztelefone an diese
Steckdosen anschließen.
Entweder geschützte oder ungeschützte Buchsen dürfen an diese Datensteckdosen angeschlossen werden.
Handling SFPs
To prevent potential damage from electrostatic discharge, always observe the following when handling SFP
Transceivers:
■
■
■
■
Always wear an anti-static wristband connected to a suitable earth point.
Do not remove an SFP Transceiver from its packaging until you are ready to install it into a switch.
Do not touch any of the pins, connections or components of an SFP Transceiver.
Always store or transport an SFP Transceiver in antistatic packaging.
Regulatory Compliance
Laser Eye Safety: FDA 21(J) CFR, EN 60825-1/2.
Electrical Safety: EN/UL 60950
Inserting the Transceiver
The SFP Transceiver is keyed and there is only one way in which it can be installed correctly. It is not necessary to power-down your Switch.
1 Read and follow all safety precautions stated earlier in this guide.
2 Hold the transceiver so that the connector is toward you and the product label is visible. Ensure the wire release lever is closed (in the upright position). See
Figure 1.
3 Gently slide the transceiver into the SFP port until it clicks. If the transceiver does not click into place, remove it, turn it over and re-insert.
4 Remove the plastic protective cover if fitted.
5 Use an appropriate cable to connect the transceiver to a suitable device.
Product label
Temperatur e
S
S
5
17
P
P
5
17
S
S
6
18
P
P
P = P
S = S ack tatu s
On = enabled, link OK Flashing = disabled
S
S
7
19
P
P
6
S
8
S
20
P
P
7
18
8
19
20
Suitable port on host Switch
Figure 1 Inserting the Transceiver (for example purposes only, this figure shows a 1000BASE-SX SFP Transceiver)
Removing the Transceiver
It is not necessary to power-down your Switch.
1 Disconnect the cable from the transceiver.
2 Move the wire release lever downwards until it is pointing toward you.
3 Pull the wire release lever toward you to release the catch mechanism; the transceiver will then easily slide out.
Problem Solving
If you suspect a problem, carry out these steps before contacting your supplier:
■
■
■
Refer to the documentation supplied with your Switch for general problem solving information.
Ensure that you have followed the installation instructions in this guide, and the transceiver is correctly installed in the Switch.
Ensure that the Switch in which the transceiver is fitted
■
■
■
■ is powered-up.
Ensure that the device at the far end of the link is powered-up and operating correctly.
Ensure that all connectors on the fiber optic segment are correctly engaged (1000BASE-SX, 1000BASE-LX,
1000BASE-LH70 SFP Transceivers only).
Clean the fiber terminators by wiping them gently with a clean tissue or cotton bud moistened with a little ethanol. Dirty fiber terminators on the fiber optic segment impair the quality of the light transmitted through the cable (1000BASE-SX, 1000BASE-LX,
1000BASE-LH70 SFP Transceivers only).
To remove an LH70 SFP Transceiver that has been inserted with the wire release lever pointing down, push the blue plastic at the base of the transceiver inwards towards the unit to release the catch mechanism.
For information about obtaining technical support, refer to "Technical Support" in this guide.
Technical Specifications
1000BASE-LH70, 1000BASE-SX, 1000BASE-LX SFP Transceivers
The 1000BASE-LH70 SFP Transceiver supports a direct connection to single-mode fiber-optic cable, the 1000BASE-SX SFP Transceiver supports a direct connection to multi-mode fiber-optic cable and the 1000BASE-LX SFP Transceiver supports a direct connection to both. Table 1 shows the ranges for each connection.
Table 1 Transmission Ranges
Fiber Type
1000BASE-SX
Multimode
Multimode
Multimode
Multimode
10000BASE-LX
Multimode
Multimode
Multimode
Single-mode
1000BASE-LH70
Single-mode
Diameter
(microns)
62.5
62.5
50
50
62.5
50
50
9
9 core
Modal
Bandwidth
(MHz • km)
160
200
400
500
500
400
500
-
-
Minimum
Connector
End Polish
-
-
-
-
-
-
-
-
PC
Transmission Range
2 m - 220 m (6.6 ft - 721.8 ft)
2 m - 275 m (6.6 ft - 902.3 ft)
2 m - 500 m (6.6 ft - 1640.5 ft)
2 m - 550 m (6.6 ft - 1804.6 ft)
2 m - 550 m (6.6 ft - 1804.6 ft)
2 m - 550 m (6.6 ft - 1804.6 ft)
2 m - 550 m (6.6 ft - 1804.6 ft)
2 m - 10,000 m (6.6 ft - 32,810 ft)
2 m - 70 km (6.6 ft - 43 miles)
Table 2 shows the optical characteristics for the transmitter and receiver for each Transceiver.
CAUTION: If using cable lengths shorter than 25 km with the 1000BASE-LH70 SFP Transceiver, you must ensure that a single-mode fiber attenuator is used to avoid signal saturation.
Table 2 Optical Characteristics
Parameter
Transmitter:
Output Optical Power
(Average)
Receiver:
Optical Input Power
Transmitter:
Output Optical Power
(Average)
Receiver:
Optical Input Power
Transmitter:
Output Optical Power
(Average)
Receiver:
Optical Input Power
Symbol
Pout
PR
Pout
PIN
Pout
PIN
Minimum
-9.5
-17
9.5
-20
0
-24
Typical Maximum
-6.5
-
-
-
-
-
0
0
-3
-3
+3
-3
Unit dBm dBm dBm dBm dBm dBm
1000BASE-T SFP Transceiver
The 1000BASE-T SFP Transceiver port uses Category 5 copper cabling with RJ-45 connectors, and supports segment lengths of up to 100 m (328 ft), as specified in the Gigabit Ethernet standard
IEEE802.3-2000.
CE Statement (Europe)
This product complies with the European Low Voltage Directive 73/23/EEC and the EMC Directive
89/336/EEC as amended by European Directive 93/68/EEC.
Technical Support
To obtain telephone support as part of your warranty and other service benefits, you must first register your product at http://eSupport.3com.com/
The following options are available for technical support:
■
■
Contact your network supplier.
Check the 3Com knowledgebase at
■ http://knowledgebase.3com.com
Browse the 3Com web site at http://www.3com.com
Please have your product model name, part number and serial number (found on underside of transceiver) along with all relevant details of the problem to hand before calling your network supplier or 3Com.
Telephone numbers are correct at the time of publication.
Find a current directory of support telephone numbers posted on the 3Com web site at http:// csoweb4.3com.com/contactus/.
Country
Asia, Pacific Rim
Telephone Number
Australia
Hong Kong
India
Indonesia
Japan
Malaysia
New Zealand
Pakistan
Philippines
P.R. of China
Singapore
S. Korea
Taiwan
Thailand
1 800 678 515
800 933 486
+61 2 9424 5179 or
000800 650 1111
001 803 61009
00531 616 439 or
03 5977 7991
1800 801 777
0800 446 398
+61 2 9937 5083
1235 61 266 2602 or
1800 1 888 9469
10800 61 00137 or
021 6350 1590 or
00800 0638 3266
800 6161 463
080 333 3308
00801 611 261
001 800 611 2000
You can also obtain support in this region using the following e-mail: [email protected]
Or request a repair authorization number (RMA) by fax using this number: + 65 543 6348
Europe, Middle East, and Africa
From anywhere in these regions, call:
+44 (0)1442 435529
From the following countries, you may use the numbers shown:
Austria
Belgium
Denmark
Finland
France
Germany
Hungary
Ireland
Israel
Italy
Luxembourg
Netherlands
Norway
Poland
Portugal
South Africa
Spain
Sweden
Switzerland
U.K.
01 7956 7124
070 700 770
7010 7289
01080 2783
0825 809 622
01805 404 747
06800 12813
01407 3387
1800 945 3794
199 161346
342 0808128
0900 777 7737
815 33 047
00800 441 1357
707 200 123
0800 995 014
9 021 60455
07711 14453
08488 50112
0870 909 3266
You can also obtain support in this region using the following URL: http://emea.3com.com/support/ email.html
Country Telephone Number
Latin America
Antigua
Argentina
Aruba
Bahamas
Barbados
Belize
Bermuda
Bonaire
Brazil
Cayman
Chile
Colombia
Costa Rica
Curacao
Ecuador
Dominican Republic
Guatemala
Haiti
Honduras
Jamaica
Martinique
Mexico
Nicaragua
Panama
Paraguay
Peru
Puerto Rico
Salvador
Trinidad and Tobago
Uruguay
Venezuela
Virgin Islands
1 800 988 2112
0 810 444 3COM
1 800 998 2112
1 800 998 2112
1 800 998 2112
52 5 201 0010
1 800 998 2112
1 800 998 2112
0800 13 3COM
1 800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
1 800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
57 1 657 0888
AT&T +800 998 2112
1 800 998 2112
571 657 0888
01 800 849CARE
AT&T +800 998 2112
AT&T +800 998 2112
54 11 4894 1888
AT&T +800 998 2112
1 800 998 2112
AT&T +800 998 2112
1 800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
57 1 657 0888
You can also obtain support in this region using the following:
Spanish speakers, enter the URL: http://lat.3com.com/lat/support/form.html
Portuguese speakers, enter the URL: http://lat.3com.com/br/support/form.html
English speakers in Latin America should send e-mail to: [email protected]
North America & Canada 1 800 876 3266
Register Your Product
To take advantage of warranty and other service benefits, you must first register your product at http:// eSupport.3com.com/ . 3Com eSupport services are based on accounts that you create or have authorization to access. First time users must apply for a user name and password that provides access to a number of eSupport features including Product Registration, Repair Services, and Service Request.
3Com Corporation , Corporate Headquarters
350 Campus Drive,
Marlborough, MA 01752-3064
To learn more about 3Com products and services, visit our
Word Wide Web site at www.3com.com.
All specifications subject to change without notice.
Lejupielādēt
Reklāma