Premier BP-3946 Instruction Manual

Add to My manuals
20 Pages

advertisement

Premier BP-3946 Instruction Manual | Manualzz

MANUAL DE INSTRUCCIONES

BP-3946

Venezuela:

Sitio Web:

E-mail:

0800 ELECTRIC (353-2874)

300-5185 www.premiermundo.com

[email protected]

NOTA

unidad sin previo aviso, con el fin de continuar las mejoras y desarrollo del mismo.

ESTIMADO CLIENTE

a su futura referencia.

Si necesita soporte adicional, no dude en escribir a:

[email protected]

....................................................................................................................................... 2

INSTRUCCIONES DE SEGURIDAD......................................................................................................... 2

............................................................................................................... 3

INDICADORES DE LA UNIDAD................................................................................................................ 4

....................................................................................................... 5

RECOMENDACIONES AL USAR LA UNIDAD ......................................................................................... 5

.......................................................................................................... 6

........................................................................................................................................ 7

USO DEL BRAZALETE ............................................................................................................................. 8

........................................................................................................................ 10

INSTRUCCIONES PARA CONDICIONES ESPECIALES....................................................................... 10

........................................................................................................................ 11

........................................................................................................ 12

.............................................................................................................. 12

....................................................................................................... 12

............................................................................... 13

.................................................................................. 13

....................................................................... 13

INDICADORES DE ERROR .................................................................................................................... 14

S ................................................................................................................. 14

CUIDADO Y MANTENIMIENTO.............................................................................................................. 14

ESPECIFICACIONES.............................................................................................................................. 15

OBSERVACIONES.................................................................................................................................. 15

P-1

lo-

INSTRUCCIONES DE SEGURIDAD

Lea este manual de usuario antes de usar la unidad.

proveedor de salud.

Evite usar celulares cerca de la unidad, ya que esto puede producir un mal funcionamiento.

correctos.

No intente reparar los componentes de la unidad.

No use la unidad en lugares donde haya gas inflamable

2002/96/EC

La unidad, accesorios y su empaque deben ser depositados en un lugar ade

P-2

CUERPO

Conector de Aire

IDAD.

Pantalla

Boton de Memoria

Boton de Ajustes

Boton iniciar / Detener

Compartimiento de las baterias

Conector para adaptador AC

Conector de Aire

PANTALLA

Indicador de bateria baja

Indicador de inflado y

WHO

Indicador de valor promedio

Memoria y tiempos unidad

Indicador de pulso

P-3

BRAZALETE

Enchufe de aire

Manguera

Metal

Si e encuentra en perfecto estado.

FUENTE DE PODER

Adaptador AC (No incluido)

1.

2. Cuando use un adaptador AC (Opcional), este debe corresponder con las normas requeridas

IEC60601-1: 1988+A1: 1991+A2: 1995.

3.

salida: 1-

INDICADORES DE LA UNIDAD

Indicador

Cuando la unidad detecta un ritmo irregular dos o mas

Un ritmo irregular en los latidos d

Pulso o 25% mas que el ritmo promedio detectado mientras el

arterial recomendamos que consulte a su medico.

P-4

)aparece

Pulso

arterial

Corto Largo

ANTES DE TOMAR UNA M

El brazalete puede ser puesto en el brazo izquierdo o derecho.

mediciones.

Espere 30 y 60 segundos entre mediciones. El tiempo de espera permite que las arterias regresen

RECOMENDACIONES AL USAR LA UNIDAD

1.

Postura adecuada

Mantenga su cuerpo recto y relajado

2. Coloque el brazalete directamente sobre su piel.

Altura adecuada

En el mismo nivel de

Uso correcto

coloque el brazalete sobre su piel.

3. La manguera debe estar ubicada en el interior del brazo. La parte inferior del brazalete debe estar aproximadamente en 1~2Cm sobre su codo.

4. Envuelva el brazalete alrededor de su brazo. No son permitidos mas de dos dedos de distancia entre el brazalete y su brazo.

P-5

5.

6.

brazalete se desinfle completamente.

1.

2.

polaridad.

3.

NOTA

: la pantalla de la unidad.

a unidad.

P-6

Ajustar la fecha y hora

que no haya ajustado la fecha y la hora actual.

1.

intermitente en la pantalla. Esto es para recordarle que la fecha y la hora deben ser ajustadas.

2.

cuando la unidad se haya apagado.

3.

4.

5.

Ajuste del mes s se tornara intermitente.

6. Ajuste la hora y los minutos usando los pasos anteriores.

P-7

Ajuste de la hora

Ajuste de los minutos

7.

Ajuste de la unidad

8.

USO DEL BRAZALETE

1.

2. Coloque el brazalete directamente sobre la piel.

3.

P-8

4.

5. Coloque el brazalete en su brazo.

erior.

6. La manguera debe estar ubicada en el interior del brazo. La parte inferior del brazalete debe estar aproximadamente en 1~2Cm sobre su codo.

7. Envuelva el brazalete alrededor de su brazo.

8. Tenga su brazo relajado, y mantenga la palma de su mano hacia arriba y sus dedos curveados

P-9

1.

la un completad es borrado para guardar la mediciones tomadas.

lectura promedio.

2.

3.

o son detectada en la pantalla.

4. Presione el bo apagarla.

Indicador kPa

INSTRUCCIONES PARA CONDICIONES ESPECIALES

Indicador mmHg

Indicador IHB minutos antes de la sig

P-10

ultimo valor de

Borrar Los Valores Almacenados En La Memoria

presione el bot -4 segundos.

ro 90.

Hacia

Hacia numero 90

P-11

A

segmentos de la barra indicadora la cual corresponde al indica

por la r

Rojo

Amarillo

Azul

Salida de sangre

Aumento de la pre

disminuye a

(Valor objetivo) normal

NOTA:

neos reduciendo la elasticidad de graves, como el infarto de miocardio y accidente cerebrovascular. Por estas razones es muy importante

encuentra en un rango normal.

P-12

Sobrepeso

Nivel de colesterol alto

Fumar

Consumo de alcohol excesivo

Consumo de sal excesivo

Falta de ej

TRATAMIENTO DE LA PR

Puede ayudar los tratamientos prescritos por su medico de la siguiente manera:

Perdiendo peso y bajando su nivel de colesterol.

Reduciendo el consumo de alcohol.

Reduciendo las cantidades de sal en los alimentos.

No fumando.

Haciendo ejercicio regularmente.

res a 90~95 mmHg en

P-13

INDICADORES DE ERROR

Causa

Se ha producido un error al inflar el brazalete.

Envuelva el brazalete correctamente aire esta instalado correctamente en la unidad

No mueva su brazo y su cuerpo. muy baja usadas con unas nuevas.

S

Problema

No enciende

No aparecen los indicadores en la pantalla altos o demasiado bajos

Reem nuevas.

correctamente nte.

como fue envuelto el brazalete, pueden afectar su

CUIDADO Y MANTENIMIENTO

CUIDADO

Mantenga la unidad en su estuche mientras no la use.

Nunca sumerja la unidad en agua o en cualquier otro liquido.

MANTENIMIENTO

No limpie la unidad ni sus accesorios con detergentes o productos abrasivos.

No moje el brazalete con agua

Guarde la unidad en un lugar limpio y seco. No la exponga a humedad o a los rayos directos del sol.

Use la unidad de acuerdo con lo especificado en este manual

Use solo accesorios autorizados por el fabricante.

P-14

ESPECIFICACIONES

Modelo No.

Pantalla

Exactitud

Indicador LCD

Ambiente de almacenamiento

OBSERVACIONES

Pulso

Pulso

Pulso

Indicador

BP-3946

Pantalla digital LCD

Brazo superior

0 a 299 mmHg (0~39.9 kPa)

40 a 199 Pulsos/min

+/-3 mmHg (0.4 Kpa)

+/-5% de lectura

Pa

Memoria / Promedio / IHB / baja, etc.

Inflado

Desinflado

memoria

Fuente de poder

Peso de la unidad principal

Brazalete

Accesorios

Memoria de 9

En 2 minutos

Brazalete suave

Brazalete,

Temperatura

Humedad anual de instrucciones

Temperatura -

Humedad

105 ~ 80 kPa

-

10 ~ 95%

D.C 6V

La unidad satisface los requerimientos de IEC60601-

-

Esta unidad ha pasado la prueba EMC.

obtenidos por un observador entrenado utilizando o, EN1060-1:

El riesgo del paciente y el usuario puede bajar a un nivel aceptable.

Cambiar

La ley federal restringe la venta de esta unidad por la orden de un medico.

Esta unidad no debe ser usada cerca de inflamantes mixtos.

Puede que en condiciones de uso o almacenamiento inadecuados, se reduzca el rendimiento de la unidad.

P-15

INSTRUCTION MANUAL

Blood Pressure Monitor

BP-3946

MEM

START/STOP

SET

MEM

DEAR CUSTOMER

In order to achieve the best performance of your product, please read this instruction manual carefully before using, and keep it for future reference.

If you need extra support, please write to

[email protected]

PREMIER CUSTOMER SERVICE

Venezuela: 0800 – ELECTRIC (353-2874)

Panama: 300-5185

Website

E-mail:

www.premiermundo.com

[email protected]

NOTE

This unit may be submi ed to changes in speci?ca ons,characteris cs and/or opera on without prior no ce tothe user, in order to con nue improving and developing its technology.

P-1

Table of Contents

Introduction .................................................................................3

Important Safety Notes ...............................................................3

Know Your Unit

---- Main Unit ...............................................................................4

---- Accessorial Components ......................................................5

Unit Display.................................................................................6

Before Taking A Measurement ....................................................7

Quick Reference Guide ..............................................................8

Battery Installation / Replacement ..............................................9

Initialization

---- How to Set the Date and Time ...........................................10-11

Proper Use of the Arm Cuff .....................................................12-13

Take a Measurement ................................................................14

Use the Memory Function ........................................................15

About Blood Pressure

---- Blood Circulation .................................................................16

---- Health and Blood Pressure .................................................17

---- Classification of Blood Pressure .........................................17

Exceptional Situations

---- Error Indicators ...................................................................18

---- Eliminate Fault ....................................................................18

Care and Maintenance .............................................................19

Specifications ...........................................................................20

Statement .................................................................................21

P-2

Introduction

Thank you for purchasing Fully Automatic Upper Arm Style Digital

Blood Pressure Monitor.

The unit uses the oscillometric method of blood pressure measurement.

It means the unit detects the movement of your blood through your brachial artery, and converts your blood pressure into a digital reading.

The unit is simple to use because a stethoscope is not needed while using an oscillometric monitor.

The unit stores automatically 90 sets of measurement values with the measuring date and time in the memory. You can read the stored data conveniently by pressing the memory buttons.

Type B applied part

Attention, consult ACCOMPANY DOCUMENTS

Important Safety Notes

To assure the correct use of the product basic safety measures should always be followed including the precautions listed below:

Read all information in the instruction manual and any other literature included in the box before using the unit.

Contact your physician for specific information about your blood pressure.

Follow the instructions of your healthcare provider.

Operate the unit only as intended. Do not use for any other purpose.

The unit is intended to use in measuring blood pressure and pulse rate for adult only, not recommended for neonatal baby.

Do not use a cellular phone near the unit. It may result in operational failure.

Please avoid using in high radiant area in order to make your measuring data correctly.

Do not plug or unplug the adapter power cord with wet hands.

Do not disassemble or attempt to repair the unit or components.

Do not use the equipment where flammable gas (such as anesthetic gas, oxygen or hydrogen ) or flammable liquid (such as alcohol) are present

P-3 P-4

P-5

Unit Display

When the unit detects an irregular rhythm two or more time during the measurement, the irregular heartbeat Symbol will appear on the display

with the measurement values.

Normal Heartbeat

An irregular heartbeat

Pulse

rythm is defined as a rhythm that varies by less than 25% from

the average rhythm or

25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.

Pulse

Irregular Heartbeat

Short Long

If the Irregular Heartbeat Symbol( IHB ) displays with your measurement results, we recommend you consult your physician

Follow the directions of your doctor.

P-6

Before Taking A Measurement

1. Avoid eating, drinking, alcohol, smoking, exercsing and bathing for 30

minutes before takinga measurement. Rest for at least 15 minutes before

taking the measurement.

2. Stress raises blood pressure. Avoid taking measurements during stressful

times.

3. The cuff can be applied to your left or right wrist.

4. Measurements should be taken in a quiet place.

5.Position the unit at heart level throughout the measurement.

6. Remain still and do not talk during the measurement.

7. Keep a record of your blood pressure and pulse readings for your

physician. A single measurement does not provide an accurate indication

of your trueblood pressure. You need to take and record several readings

over a period of time. Try to measureyour blood pressure at the same time

each day for consistency.

8. Wait 30~60 seconds between measurements.

The wait time allows the arteries to return to the condition prior to taking the blood pressure mesurement.You may need to increase the wait time

depending on you individual physiological characteristics.

Quick Reference Guide

1.

Please take off thick clothing and keep yourself quiet for 5~10 minutes before taking a measurement.

2.

Remove all clothes from your upper arm allowing the cuff to fit directly on the skin.

Proper posture

Keep your body straight and relaxing.

Proper height

At the same level as your heart.

Proper wrapping

Wrap the cuff tightly on the skin.

3.

The hose runs down the inside of your arm. The bottom of the cuff should be approximately 1~2cm above your elbow.

4.

Wrap the cuff properly around your upper arm. Not more than

2-finger-room allowed between the cuff and your arm.

1 ~ 2cm

P-7

5.

Press the START/STOP button. All symbols appear, then the cuff starts to inflate automatically.

SYS mmHg

DIA mmHg

PUL

/min

MEM SET MEM

6.

The blood pressure and pulse rate are displayed when the measurement completed, and the arm cuff deflates completely.

START/STOP

P-8

Battery Installation / Replacement

How to Install Battery

1

Remove the battery cover from the battery compartment.

2

Insert four AA powerful batteries into the compartment and ensure each battery is in the proper direction.

3

Replace the battery cover.

The battery cover will be closed tight when you hear a clicking sound.

P-9

Caution!

Use four identical 1.5V alkaline batteries type AA LR6.

Replace all of the batteries if the symbol of low battery appears on the display.

Never leave any low battery in the battery compartment since they may leak and cause damage to the unit.

Initialization

How to Set the Date and Time

The unit automatically stores 90 sets measurement values with the date and time. Set the unit to the current date and time before taking a measurement for the first time. A default date and time will display if the current date and time is not set.

1.

All informations will appear on the display when

the batteries are installed at the first time, after

2 seconds the year flashes on the display.

2.

Long press the setting button until the year is mmHg

displayed when the unit powered off.

DIA mmHg

PUL

/min

MEM SET MEM

START/STOP

MEM

KINGYIELD KINGYIELD

3.

Press the memory up button to increase one year.

MEM

SYS

Press the memory down button to decrease one year.

DIA mmHg

Year

Setting

PUL

/min

SYS mmHg

DIA mmHg

PUL

/min

MEM SET MEM MEM SET

MEM

START/STOP START/STOP

KINGYIELD

SYS mmHg

The year can be set between 2008 and 2030. When the display reaches

DIA mmHg to 2030, it will return to 2008.

PUL

/min

4.

Press the Setting button to set the

current year.

After that the month flashes on the

display.

MEM SET MEM

START/STOP

5.

Press the memory up button to increase one month.

Press the Setting button to set the current month.

After that the day flashes on the display.

P-10

Month

Setting

KINGYIELD

Initialization

SYS mmHg

DIA mmHg

PUL

/min

MEM SET MEM

KINGYIELD

SYS mmHg

DIA mmHg

PUL

/min

MEM SET MEM

Day

Setting

MEM SET MEM

SYS mmHg

DIA mmHg

PUL

/min

MEM SET MEM

START/STOP START/STOP

KINGYIELD

6.

Setting the hour and minute by using the same way.

KINGYIELD

SYS mmHg

DIA mmHg

DIA mmHg

Hour

Setting

PUL

/min

PUL

/min

MEM SET MEM MEM SET MEM

SYS mmHg

DIA mmHg

PUL

/min

Minute

Setting

MEM SET MEM

START/STOP

SYS mmHg

DIA mmHg

PUL

/min

MEM SET MEM

START/STOP

SYS mmHg

DIA mmHg

PUL

/min

KINGYIELD KINGYIELD

7.

After setting the minute, next step to select display unit (kPa or mmHg).

SYS mmHg

SYS mmHg

Unit

Setting

DIA mmHg

DIA mmHg

PUL

/min

PUL

/min

MEM SET MEM MEM SET MEM

START/STOP START/STOP

8.

After completing all the settings, press the START/STOP button to shut off.

P-11

Proper Use of the Arm Cuff

How to Use the Arm Cuff

1

Make sure the air plug is inserted properly in the main unit.

MEM

SYS mmH g

DIA mmHg

PUL

/min

MEM

SET

STAR

T/ST

OP

2

3

Remove all clothes from your upper arm allowing the cuff to fit directly on the skin.

Sit in a chair with your feet flat on the floor.

Place your arm on a table so as to level the cuff to your heart.

4

Pass the end of the cuff through the metal, and keep the hose outward.

P-12

Proper Use of the Arm Cuff

5

Put your arm through the loop, and pull it up to the position of your upper arm.

6

The hose runs down the inside of your arm. The bottom of the cuff should be approximately 1~2cm above your elbow.

7

Wrap the cuff properly around your upper arm.

Not more than

2-finger-room allowed between the cuff and your arm.

8

Have your upper arm relax, keep your palm upward and your fingers curving naturally, then turn on the unit and start to measure.

P-13

1 ~ 2cm

Take a Measurement

How to Take a Measurement

1

KINGYIELD

mmHg

All display symbols appear on the screen. The cuff starts to inflate automatically.

DIA mmHg

PUL

/min

MEM SET

MEM

START/STOP

2

Inflation stop automatically and the measurement is started.

The heartbeat symbol flashes once a pulse is detected.

3

The blood pressure and pulse rate are displayed when the measurement completed.

The cuff is deflated automatically, and all of the measurement results are stored in the memory with date and time.

OR OR arrhythmia is detected.

"kPa" display "mmHg" display "IHB" display

4

Press the START/STOP button to turn off the unit.

The unit will automatically turn off after 2 minutes if you have forgotten to turn off it.

INSTRUCTIONS FOR SPECIAL CONDITIONS

In order to accelerate the measurement time for the systolic pressure more than 180 mmHg, press and hold the memory button until the unit inflates 30 to 40 mmHg higher than your suspected systolic pressure if you know. (

The unit will not inflate above 299 mmHg).

Please rest for at least 3 minutes before taking the next measurement.

P-14

Use the Memory Function

How to Use the Memory Function

The unit stores the blood pressure and pulse rate in the memory after completing a measurement every time. It can automatically store 90 sets of measurement values. The oldest record is deleted to save the latest measurement value when more than 90 sets.

The unit also calculates an average reading based on the values of the latest 3 times measurement taken.

mmHg on the screen with the average reading.

DIA mmHg

PUL

/min

MEM SET MEM

START/STOP

Alternating display

To display the measurement values

Press the memory up button to view the oldest measurement value.

SYS mmHg

Press the button repeatedly to display the next value.

DIA mmHg

Backward

PUL

/min

MEM SET MEM

START/STOP

The 1st latest measurement value

The 2st latest measurement value

To delete all values stored in the memory

Forward

The 90st latest measurement value

MEM SET MEM

START/STOP

SYS mmHg

DIA mmHg

PUL

/min

P-15

About Blood Pressure

Blood Circulation

The blood circulation is responsible for supplying the body with oxygen.

Blood pressure is the pressure exerted on the arteries.

The systolic blood pressure value (higher pressure or top value) represents the blood pressure produced by contraction of the heart muscle.

The diastolic blood pressure value (lower pressure or lower value) represents the blood pressure produced by relaxation of the heart muscle.

Systolic Blood Pressure Diastolic Blood Pressure

Contraction of the heart muscle

Extrude blood

Pressure increased to the blood vessel

Higher pressure

Relaxation of the heart muscle

Blood return heart

Pressure decreased to the blood vessel

Lower pressure

Health and Blood Pressure

The incidence of hypertension increases with age. In addition, a lack of exercise, excess body fat and high levels of cholesterol (LDL), which sticks to the inside in blood vessels, reduces elasticity of these vessels. Hypertension accelerates arterial sclerosis which can lead to very serious conditions such as stroke and myocardial infarction. For these reasons it is very important to know whether the blood pressure is within a healthy range. Blood pressure fluctuates from minute to minute, throughout the day. Therefore it is essential to take regular measurements to help you identify an average blood pressure.

200 mmHg

Upper curve: systolic blood pressure

Lower curve: diastolic blood pressure

150

100

50

6 12

Time of day

18 24

P-16

About Blood Pressure

Classification of Blood Pressure

After each measurement is completed, the LCD display will show your position automatically on the six segments of the bar indicator which corresponds to WHO Blood Pressure Indicator.

Diastolic Blood Pressur (mmHg)

Severe hypertension

110

Moderate hypertension

100

Mild hypertension

90

Normal systolic value

85

80

Normal blood pressure

Optimal blood pressure

(target value)

120 130 140 160 180 Systolic Blood Pressure (mmHg)

*Note!

When a person’s systolic and diastolic pressures fall into different categories, the higher category should apply.

WHO

Red

Yellow

Blue

Symptoms of High

Blood Pressure

Treatment of High

Blood Pressure

High blood pressure can go unnoticed for a long time, since it doesn't cause noticeable symptoms. The following are all possible causes of abnormally high blood pressure:

Overweight;

High cholesterol level;

Smoking;

Excessive alcohol consumption;

Stress and emotional upset;

Excessive consumption of salt;

Lack of physical exercise;

Genetic / hereditary predisposition;

Underlying illnesses, such as kidney disorders or endocrine disturbance.

If your blood pressure reaches upper values of 140~160 mmHg and lower values of 90~95 mmHg in repeated measurements over several days, you should consult your doctor for detailed medical examination. You can assist the treatment prescribed by your doctor in the following ways:

Loose weight and lower your cholesterol level;

Reduce the consumption of alcohol;

Reduce the intake of salt;

Stop smoking;

Take regular exercise;

Monitor your blood pressure.

P-17

Exceptional Situations

Error Indicators

The following symbol will appear on the display when measuring abnormal.

Symbol

The course of inflating appears error.

Cause Correction

Wrap the cuff properly.

Make sure that the air plug is properly inserted in the unit.

Inflate over again after ensuring.

Do not move your arm and body, and keep quiet.

When measurement fails.

Measure over again according to correct way.

When the batteries power are too low.

Replace all of the worn batteries with new ones.

Eliminate Fault

No power.

Problem

No display appears on the display screen.

Measurement values appear too high or too low.

Causes and Solutions

Replace all the worn batteries with 4 new ones.

Check the battery installation for proper placement of the batteries polarities.

Blood pressure varies constantly. Many factors including stress, time of day, how you wrap the cuff, may affect your blood pressure. Review the sections "Proper Use of the Arm Cuff" and "Take a Measurement".

P-18

Care and Maintenance

Care

Keep the unit in the storage case when not in use.

Clean the unit with a soft dry cloth.

Do not use any abrasive or volatile cleaners.

MEM

SET

KINGYIELD

MEM

Never immerse the unit or any components in water.

START/STOP

※If needed, please use ultraviolet radiation for disinfection.

Maintenance

Do not clean the body and cuff with naphtha, thinner or gasoline etc.

Do not wet the cuff or attempt to clean the cuff with water.

thinner gasoline

Store the unit in a clean and dry location. Do not subject the unit to extreme hot or cold temperature, humidity and direct sunlight.

Remove the batteries if the unit will not be used for 3 months or longer.

Always replace all of the batteries with new ones at the same time.

MEM

SET

START/STO

P

MEM

Use the unit consistent with the instructions provided in this manual.

Use only authorized parts and accessories.

P-19

Specifications

Model No.

Display

Measuring Principle

Measurement Localization

Measurement

Range

Accuracy

LCD

Indication

Pressure

Pulse

Pressure

Pulse

Pressure

Pulse

Symbol

BP-3946

LCD Digital Display

Oscillometric Method

Upper Arm

0 ~ 299 mmHg (0 ~ 39.9 kPa)

40 ~ 199 Pulses/min

3 mmHg (0.4 kPa)

5% of reading

3 Digits Display of mmHg or kPa

3 Digits Display

Memory/Average/IHB/Heartbeat/Low Battery, etc.

Inflation

Deflation

Rapid Air Release

Memory Function

Power Source

Automatic Power-Off

Main Unit Weight

Cuff

Accessorial Components

Operating

Environment

Storage

Environment

Automatic by Internal Pump

Automatic by Air Valve

Automatic by Air Valve

Memory 90 Sets of Measurement Values

4 AA Alkaline Batteries or AC/DC Adapter; D.C. 6V

In 2 Minutes

Approx. 300g (Batteries not included)

Soft Arm Cuff

Cuff, Batteries, Instruction Manual

Temperature

Humidity

Barometric Pressure

Temperature

Humidity

10 ~ 40 °C (50 ~ 104 °F)

15 ~ 90%RH (Noncondensing)

105 ~ 80 kPa

-20 ~ 60 °C (-4 ~ 140 °F)

10 ~ 95%RH (Noncondensing)

P-20

P-21

Statement

The intended use: The unit is intended to be used by adults at home or

medical centre to measure blood pressure and pulse rate from the upper

arm.

The unit satisfies the requirements of IEC60601-1 Medical electrical

equipment,EN1060-1:Non-invasive sphygmomanometer,EN1060-3:

Non-invasive sphygmomanometer

The unit has passed the EMC Test.

Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultatory method, within the limits prescribed by the American National Standard, Manual, electronic, or automated sphygmomanometers.

The risk of patient and user can be lowered to acceptable level.

Substitution of a cuff different from that supplied might result in

measurement error.

Specifications are subject to change without notice due to improvements in performance.

Federal law restricts this device to sale by or on the order of a physician.

Equipment not suitable for use in the presence for flammable mixtures

The unit might not meet its performance specifications if stored or used outside the following spcified temperature and humity ranges

VER:A00