ADC 6014 Instruction Manual
The ADC 6014 Advanced Blood Pressure Monitor is a user-friendly device that provides accurate and reliable blood pressure and pulse rate measurements at home. Its clinically proven accuracy ensures consistent results. With its advanced features like dual user memory, averaging mode, and optional PC connectivity, it's an ideal tool for managing and tracking your cardiovascular health.
Реклама
Реклама
Digital
Blood Pressure
Monitor
Advanced Blood Pressure Monitor
6014
Instruction Manual
EC REP
ADC
55 Commerce Drive
Hauppauge, NY 11788
ADC (UK) Ltd.
Unit 6, PO14 1TH
United Kingdom
Inspected in the U.S.A.
Made in China tel: 631-273-9600, 1-800-232-2670 fax: 631-273-9659
www.adctoday.com
email: [email protected]
PLEASE NOTE:
THIS MEDICAL INSTRUMENT MUST BE
USED ACCORDING TO INSTRUCTIONS
TO ENSURE ACCURATE READINGS.
Questions?
Call ADC toll free at 1-800-232-2670
6014 Advanced Blood Pressure Monitor
Table of Contents
1.
Introduction
2.
About Blood Pressure
2.1 What is Blood Pressure?
2.2
What is a Normal Blood Pressure?
2.3
What Influences Blood Pressure?
2.4
Does Blood Pressure Vary?
2.5
What is Hypertension?
2.6
Can Hypertension Be Controlled?
2.7
Why Measure Blood Pressure at Home?
2.8
How is Blood Pressure Measured?
2.9
How Should I Record My Blood Pressure?
3. Components of Your Blood Pressure Monitor
4. Setting Up Your Blood Pressure Monitor
4.1. Inserting the Batteries
4.2. Using an AC Power Adapter
4.4. PC Link Connection
4.5. Setting the Time and Date
4.6. Reading the Set Date
5. The measurement procedure
5.1.
Before Measuring
5.2. Common Sources of Error
5.3. Fitting the Cuff
5.4. Measurement Mode Selection (single or average mode)
5.6. Discontinuing a Measurement
5.7. Memory – Recall of the Measurements
5.8 Clearing the memory
6. PC Link Software Functions: An Optional Accessory
8. Care, Maintenance, and Recalibration
9. Warranty
10. International Quality Standards
12. Accessories
13. How to Contact Us
1
NOTES
18
12. ACCESSORIES
Special Accessories:
AC Adapter:
6013ZAC
PC Link Software/USB Cable:
6017PC
Cuff Sizes:
Adult
Large Adult
850-6013 (9” - 13” / 22.86 - 33.02cm)
850-6013X (13” - 17” / 33.02 - 43.18cm)
13. HOW TO CONTACT US
To register your product and obtain further detailed user information about our products and services, visit us at:
www.adctoday.com
and follow the links.
For questions, comments, or suggestions call us toll free at:
1-800-232-2670
®
American Diagnostic Corporation
55 Commerce Drive, Hauppauge, New York 11788
Telephone: 631-273-9600 • Fax: 631-273-9659
Email: [email protected]
17
1. INTRODUCTION
1. Introduction
Congratulations on your purchase of the advanced ADC ® ADvantage TM Blood Pressure Monitor.
In hospitals and physician's offices throughout the world, where accuracy and dependability are critical,
ADC ® professional diagnostic products are the instruments of choice.
Now you, too, can enjoy the benefits of ADC ® engineering and quality in the home. This feature rich instrument was designed to simplify the measurement of blood pressure and pulse rate at home and deliver consistent, dependable results.
Your ADC ® blood pressure monitor is a fully automatic digital blood pressure measuring device for use on the upper arm. It enables very fast and reliable measurement of the systolic and diastolic blood pressure as well as the pulse by way of the oscillometric method. This device offers clinically proven accuracy and has been designed to be user friendly.
Read this booklet thoroughly before attempting to use your new ADC ®
Pressure Monitor.
ADvantage TM Digital Blood
Remember…
• Only a health care professional is qualified to interpret blood pressure measurements. This device is
NOT intended to replace regular medical checkups.
• It is recommended that your physician review your procedure for using this device.
• Blood pressure readings obtained by this device should be verified before prescribing or making adjustments to any medications used to control hypertension. Under no circumstances should YOU alter the dosages of any drugs prescribed by your doctor.
• This monitor is intended for use by adults only. Consult with a physician before using this instrument on a child.
• In cases of irregular heartbeat (Arrhythmia), measurements made with this instrument should only be evaluated after consultation with your doctor.
• Familiarize yourself with the section titled "About Blood Pressure". It contains important information on the dynamics of blood pressure readings and will help you to obtain the best results.
NOTE!
This device contains sensitive electronic components. Avoid strong electrical or electromagnetic fields in the direct vicinity of the device (e.g. mobile telephones, microwave ovens) during use. These can lead to erratic results.
Do not attempt to service or repair this device yourself. Should a malfunction occur, refer to the back of this booklet for service information.
2
2. ABOUT BLOOD PRESSURE
2.1 What is Blood Pressure?
Simply put, arterial blood pressure is the force of blood exerted against the walls of the arteries. There are two components to blood pressure - systolic and diastolic pressure. Systolic, the higher pressure, occurs during contraction of the heart. Diastolic, the lower pressure, occurs when the heart is at "rest."
Your level of blood pressure is determined in the circulatory center of the brain and adjusts to a variety of situations through feedback from the nervous system. To adjust blood pressure, the strength and frequency of the heart (Pulse), as well as the width of circulatory blood vessels is altered. Blood vessel width is effected by fine muscles in the blood vessel walls.
Blood pressure is traditionally measured in millimeters of mercury (mmHg). It is recorded as systolic/diastolic. For example, a systolic of 120 and diastolic of 80 would be recorded 120/80.
Blood pressure is a dynamic vital sign - one that changes constantly and throughout the day. A person's "resting" blood pressure is the pressure that exists first thing in the morning while a person is still at rest and before consumption of food or drink.
2.2 What is a Normal Blood Pressure?
A systolic pressure of less than 120mmHg and a diastolic pressure of under 80mmHg are recognized as normal by the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High
Blood Pressure, 2003.
Note:
Blood pressure does increase with age, so you must check with your doctor to find out what is
"normal" for you! Even with normal blood pressure values, a regular self-check with your blood pressure monitor is recommended. You can detect possible changes in your values early and react appropriately. If you are undergoing medical treatment to control your blood pressure, keep a record of values along with time of day and date. Show these values to your doctor. Never use the results of your measurements to independently alter the drug doses prescribed by your doctor.
2.3 What Influences Blood Pressure?
Blood pressure is influenced by many factors including age, weight, physical conditioning, past illness, time of day, altitude, activity, and climate, to name just a few. In general, blood pressure is lower in the morning and increases throughout the day. It is lower in warm weather, and higher in cold weather.
Physical activity can have a significant short term impact on blood pressure. Work, exercise, smoking, eating, drinking - even talking, laughing, or crying will all affect a person's blood pressure.
Your diet, including beverages containing caffeine or alcohol, may affect blood pressure. Emotional stress can have a dramatic impact on your blood pressure.
3
9. WARRANTY
The blood pressure monitor 6014 is warranted for 5 years from date of purchase. This warranty includes the instrument and the cuff. The warranty does not apply to damage caused by improper handling, accidents, improper use, or alterations made to the instrument by third parties.
10. INTERNATIONAL QUALITY STANDARDS
Device standard: Device corresponds to the requirements of the European and U.S. standard for non-invasive blood pressure monitor
EN1060-1 / 1995
EN1060-3 / 1997
DIN 58130
ANSI / AAMI SP10
Electromagnetic compatibility: Device fulfils the stipulations of the European standard EN 60601-1-2
Clinical testing: Clinical performance tests were carried out in Germany according to the DIN 58130 / 1997 procedure N6 (sequential).
The stipulations of the EU-Guidelines 93/42/EWG for Medical Products Class IIa have been fulfilled.
11. TECHNICAL SPECIFICATIONS
Weight:
Size:
Storage temperature:
Humidity:
Operation temperature:
Display:
Measuring method:
Pressure sensor:
Measuring range:
SYS/DIA:
Pulse:
Cuff pressure display range:
Memory:
Measuring resolution:
Accuracy:
Pressure
Pulse
Power source:
Special accessories:
Reference to standards:
2.11 lbs. / 650g (with batteries)
3.66” (W) x 7.8” (L) x 9.61” (H)
124mm (W) x 205mm (L) x 81mm (H)
-20°C to +50°C
15% to 90% relative humidity maximum
10°C to 40°C
LCD (Liquid Crystal Display)
Oscillometric
Capacitive
30 to 280 mmHg
40 to 200 per minute
0-299 mmHg
Automatically stores the last 30 measurements separately for 2 users
1 mmHg within ± 3 mmHg
± 5 % of the reading
DC 6V / 600mA a) 4 size AA batteries, 1.5V
b) AC adapter / output: 6 V DC 600mA (optional)
Cuff type 850-6013X for arm circumferences 13” – 17”
(33.02-43.18 cm)
Cuff type 850-6013 for arm circumferences 9” – 13”
(22.86-33.02 cm)
EN 1060-1 /-3
DIN 58130
ANSI / AAMI SP10
16
FURTHER INFORMATION
• Even with healthy people, the level of blood pressure is subject to fluctuations. Comparable measurements always require the same conditions (Quiet conditions)!
• For licensing, the device has been subjected to strict clinical tests supervised by experienced Cardiac
Specialists.
• This device is manufactured to meet European standards under the supervision of the Technical
Monitoring Association (RWTüVEssen).
• If you have any questions regarding the use of this blood pressure monitor, call ADC
1-800-232-2670 or visit our web site at www.adctoday.com. The ADC ®
® at
Customer Service Dept. will be happy to help you.
Never attempt to repair the instrument yourself!
• Any unauthorized opening of the instrument invalidates all warranties!
8. CARE, MAINTENANCE, AND RECALIBRATION
a) Do not expose the device to extreme temperatures, humidity, dust, or direct sunlight. b) The cuff contains a sensitive air-tight bladder. Handle this carefully and avoid all types of stress through twisting or buckling.
c) Handle the tube carefully. Avoid stress from pulling, pinching, and sharp edges.
d) Clean the device with a soft, dry cloth. Do not use gasoline, thinners, or similar solvents. Carefully remove spots on the cuff with a damp cloth and soapsuds.
The cuff
should not be washed in a washing machine or in a dishwasher!
e) Do not drop the instrument or treat it roughly in any way. Avoid strong vibrations. f)
Never open the device!
This can negatively impact the calibration (accuracy). g)
Periodic re-calibration to check accuracy
Sensitive measuring devices must be checked for accuracy from time to time.
We recommend a periodic inspection of your unit by an authorized
ADC ® dealer every 2 years. Your factory authorized ADC ® dealer would be pleased to provide more information regarding calibration.
Gasoline
15
Even repeated blood pressure measurements taken without adequate rest between readings will alter your blood pressure as the vessels in your arm engorge with blood.
Many of these influences are only temporary or short term, though chronic (long term) exposure to some factors may result in permanently elevated blood pressure levels.
2.4 Does Blood Pressure Vary?
Constantly. An individual's blood pressure varies greatly on a daily and seasonal basis. It changes throughout one's lifetime. It is not uncommon for systolic pressure to vary by 40mmHg or more throughout the course of a single day! While generally not as volatile, diastolic pressure can still vary significantly. In hypertensive individuals, variations are even more pronounced. Normally, blood pressure is at its lowest during sleep and rises in the morning and throughout the day. The chart (right) illustrates the fluctuations that could occur in a typical day.
2.5 What is Hypertension?
Hypertension (high blood pressure) is elevated systolic or diastolic levels. In 90 to 95 percent of the diagnosed cases, the specific causes are unknown, although the condition is often linked with family history, and lifestyle. This is referred to as essential hypertension. In the remaining cases, high blood pressure is a symptom of an underlying, often treatable condition, which if corrected, may normalize blood pressure. This less common type is known as secondary hypertension.
Hypertension, if left untreated, may contribute to kidney disease, heart attack, stroke, or other debilitating illnesses.
The following standards for assessment of high blood pressure (without regard to age) have been established by the Joint National Committee, 2003.
Range
Classifications
Normal
Prehypertension
––
Stage 1
(Moderate)
Stage 2
(Severe)
H
Systolic Diastolic
Blood Pressure Blood Pressure
<120
120 - 139 80 - 99
Y P E
140 - 159
R T E N S
90 - 99
160+ 100+
I O N
Precaution
Measures
Contact your physician
––
Contact your physician Immediately
Contact your physician URGENTLY
(JNC-7 report: Joint National Committee on Prevention, Detection, Evaluation and Treatment of High Blood Pressure / 2003)
Remember only a physician is qualified to interpret the readings obtained from your blood pressure monitor.
No attempt should ever be made at self-diagnosis or treatment.
4
2.6 Can Hypertension be Controlled?
Although essential hypertension cannot be cured, it can usually be controlled by altering lifestyle
(including diet), adopting a program of exercise, stress management and, where necessary, with medication under a doctor's supervision.
To help reduce the risk of hypertension, or keep it under control, the American Heart Association (AHA) recommends the following:
• Don't smoke
• Reduce salt and fat intake
• Maintain proper weight
• Exercise regularly
• Have regular physical checkups
2.7 Why Measure Blood Pressure at Home?
Clinical studies have shown improved detection and treatment of hypertension when regular home blood pressure monitoring is done in consultation with a physician. Blood pressure measured in a doctor's office or hospital setting may cause anxiety and lead to an elevated reading - a condition referred to as "white coat hypertension." Home measurements generally reduce the "outside" influences on blood pressure readings, and can provide a more comprehensive and meaningful blood pressure history.
Important Note:
While it is important to keep an accurate record of your blood pressure measurements, don't be overly concerned by the results of any one measurement. Individual results may be influenced by spiking of your pressure due to diet, anxiety, or mis-measurement resulting from excessive arm movement, or misapplication of the cuff. Many readings taken at the same time each day give a more comprehensive blood pressure history. Always be sure to note the date and time when recording blood pressure and pulse measurements.
For best results, and with time permitting, 3 successive measurements may be taken daily. Make sure to allow at least 5 minute intervals between measurements. Discard any reading that appears suspect and record the average of the remaining readings.
2.8 How is Blood Pressure Measured?
Health care professionals traditionally use a device known as a sphygmomanometer along with a stethoscope - essentially a professional version of the very same instrument you have purchased. The sphygmomanometer is a system consisting of an inflatable bladder contained within a cuff, inflation bulb with air control valve, and pressure measuring manometer (gauge). The gauge may be mechanical or mercurial.
5
7. ERROR MESSAGES/TROUBLESHOOTING
If an error occurs during a measurement, a corresponding error code is displayed (Example: Err 1)
Error Number Possible Cause(s)
Err 1
Err 2
Err 3
Err 5
The systolic pressure was determined but afterwards the cuff pressure fell below 20 mmHg. This situation can occur if the tube becomes unplugged after the systolic blood pressure has been measured. Check the tube connections and repeat the measurement.
No pulse could be detected.
Unnatural pressure impulses impair the result of the measurement. The arm was moved during the measurement. Remain still and repeat the measurement.
Inflation of the cuff takes too long. The cuff is not correctly seated or the tube connection is not sealed. See Section 5.3, Fitting the Cuff.
The measured readings indicated an unacceptable difference between systolic and diastolic pressures. Take another reading following directions carefully. Contact your doctor if you continue to get unusual readings.
Other possible malfunctions
If problems occur when using the device, the following items should be checked.
Malfunction Remedy
The display remains blank when the instrument is on. Batteries have been installed.
The pressure does not rise although the pump is running.
The instrument frequently fails to measure the blood pressure values, or the values measured are too low or too high.
1. Check the polarity of the batteries(+/-)
2. If the display is erratic or unusual, remove the batteries and re-install new batteries.
1. Check the connection of the cuff tube and connect properly if necessary.
1. Ensure the cuff fits correctly.
2. Make sure the cuff is not too tight. Ensure tight clothing such as a rolled up shirt sleeve is not exerting pressure on the arm above the measuring point.
Take off articles of clothing if necessary.
3. Measure your blood pressure again in complete peace and quiet.
Every measurement produces a different value although the instrument functions normally and the values displayed are normal.
The blood pressure values measured differ from those measured by your physician.
NOTE: BLOOD PRESSURE FLUCTUATES CONTINUALLY SO
SUCCESSIVE MEASUREMENTS WILL SHOW SOME VARIABILITY.
1. Record daily values, time, and date, then consult your physician.
NOTE: INDIVIDUALS VISITING THEIR PHYSICIAN FREQUENTLY EXPERIENCE
ANXIETY WHICH CAN RESULT IN A HIGHER READING THAN ONE OBTAINED
AT HOME UNDER MORE RESTFUL CONDITIONS.
14
5.7. Memory – recall of the measurements
(Unit should be turned on first)
This blood pressure monitor automatically stores each of the last 30 measurement values separately for 2 users. By pressing the MEMORY button, the last measurement as well as the previous 29 measurements
(MR29, MR28, …MR1) can be displayed one after the other. Data obtained in average mode is indicated by an “mam“ symbol. If the memory is full, the next measurement will be added to memory and the oldest reading (MR 1) will be deleted.
Date Time Alternating Display mmHg mmHg mmHg mmHg
Average
Reading mmHg mmHg
29
MR
1 mmHg
29
MR
1 mmHg
MAM
30
MR
1
MAM
30
MR
1
Memory
User 1
(MR 30 is the value of the last measurement.)
(MR 29 is the value of the measurement before MR 30.)
5.8. Clearing the Memory – cancellation of all measurements
Attention!
Before you delete all readings stored in the memory, make sure you won’t need to refer to the readings at a later date. Keeping a written record is prudent and may provide additional information for your next physician visit. A logbook is included to record a history of your measurements.
In order to delete all stored readings, press the MEMORY button for at least 7 seconds. The display will show the symbol “CL” and 3 short beeps will sound to indicate deletion of stored readings. (Unit must be turned on.)
1
6. PC LINK SOFTWARE - OPTIONAL ACCESSORY SOLD SEPARATELY
This unit can be used in connection with your personal computer (PC) running the PC Link Blood Pressure Analyzer software. Your PC will
System Requirements for
Blood Pressure Analyzer Software
allow a capacity of monitoring 80 patients, each with 1000 data
(NOTE: Overuse will lower system efficiency). The memory data can be
• Window 98SE, 2000, XP
• CD-Rom Drive
• Minimum 256MB RAM transferred to the PC by connecting the monitor via the included USB cable with your PC.
Note: Software does not work with Mac computers.
• 500MB Available Hard Disk Space
• USB Port version 1.0 or higher
• ADC Advantage TM Blood Pressure
Monitor with USB port
6.1. Getting Started
Tracking your blood pressure is important for you and your doctor. This Blood Pressure Analyzer Software is easy to load and easy to use. Connect your blood pressure monitor to your PC and download your data. Print graphs, charts, and tables of your readings. Your blood pressure monitor can be connected to a PC using the Blood Pressure Analyzer (BPA) Software and the enclosed USB cable.
Pay close attention to the USB connection. Do not force the cable into the blood pressure monitor or your computer.
6.2. System Requirements
NOTE:
Before installing your Blood Pressure Analyzer Software, be sure that your computer meets or exceeds the following requirements:
Hardware Minimum
Microprocessor (CPU)
Memory Devices (RAM)
Hard Disk
Communications Port
550MHz
256MB
500MB
USB 1.0
Recommended
1GHz or Higher
512MB
800MB
USB 1.0 and Above
Hardware Minimum
Display
Resolution
LPT
550MHz
256MB
500MB
Recommended
1GHz or Higher
512MB
800MB
Energy Source (Power)
AC Power if use PC, AC/DC if NB
Operating System
: Windows 98SE, Windows 2000, Windows XP or above
Note:
The software does not work with Mac computers.
*.Net 1.1 framework or above required.
13
The cuff is wrapped around the limb and inflated to constrict blood flow to the artery. As pressure is released from the cuff through the deflation valve, blood flow returns to the artery producing pulse beats known as Korotkoff sounds, which are detected with the stethoscope. Systolic pressure is recorded at the onset of these sounds. Diastolic pressure is generally recorded when the sounds disappear (when blood flow to the artery returns to normal).
2.9 How should I record my blood pressure?
Record your measurements by setting up a simple chart in a spiral bound notebook as shown below, or use the enclosed record book.
Date
4/24/08
4/25/08
4/26/08
4/27/08
Time
7:50AM
8:00AM
7:45AM
2:00PM
Reading
128/83
135/77
130/75
153/89
Pulse
72
77
71
80
If you like you can add a column for comments about your condition at the time of measurement, or a listing of any factors that may have influenced your readings (such as "had a cold", or "just returned from vacation").
For best results, and with time permitting, 3 successive measurements may be taken daily. Make sure to allow at least 5 minute intervals between measurements. Discard any reading that appears suspect and record the average of the remaining readings. If this method is used, be sure to note that the readings are averaged.
3. COMPONENTS OF YOUR BLOOD PRESSURE MONITOR
The blood pressure monitor is model #6014.
It is for arm circumferences of
(9”-13” / 22.86 - 33.02cm).
Cuff Connection AC Adapter
(sold separately)
Note:
Do not force the cuff connection into the opening.
Make sure the cuff connection is not pushed into the AC adapter port. If the cuff is too small, call ADC ® for further information. A larger cuff is available.
Mode Slide Switch
User/Time/Date
On/Off
Memory
Pulse
Systolic
Diastolic
PC Link
Connection
6
4. SETTING UP YOUR BLOOD PRESSURE MONITOR
4.1 Inserting the batteries
After you have unpacked the device, insert the batteries. The battery compartment is located on the back side of the device (see illustration). a) Remove cover from the bottom plate, as illustrated.
b) Insert the batteries (4 x size AA ). Always use AA long life batteries or alkaline 1.5v batteries. Do not use rechargeable batteries.
c) If a battery warning appears in the display, the batteries are discharged and must be replaced.
Attention!
• After the battery warning appears, the device will not operate until the batteries have been replaced.
• If the blood pressure monitor will be left unused for long periods, remove the batteries from the device. *NOTE: This will erase the stored memory.
Functional check:
Hold the ON/OFF (0/I) button down to test all the display elements. When functioning correctly all elements will appear.
4.2. Using an AC power adapter (optional accessory sold separately)
It is possible to operate this blood pressure instrument with an
ADC ® AC adapter (output 6 V DC / 600 mA with DIN plug).
a) Insert the AC adapter plug into the left socket on the left side
Left
Opening of the instrument, as shown in the diagram.
b) Plug the AC adapter into a power socket. Test that power is available by pressing the ON/OFF (0/I) button.
Note:
No power is taken from the batteries while the AC adapter is connected to the instrument. If power is interrupted during the measurement, (e.g. by accidental removal of the AC adapter from the socket) the instrument must be reset by removing the plug from its socket and re-inserting the connectors. Consult ADC ® the AC adapter.
if you have questions relating to
Warning:
• Use only ADC ® or ADC ® approved adaptors on your blood
Right
Opening pressure unit. ADC ® is not responsible for damages caused by the use of non-ADC ® adaptors. Using a non-ADC ® voids the warranty on your digital blood pressure unit.
adaptor
4.3. Cuff connection
Insert the cuff tube into the right socket on the left side of the instrument, as shown in the diagram.
4.4. PC Link connection
(optional accessory sold separately)
Insert the USB connection into the opening provided on the right side of the instrument, as shown in the diagram.
7
Right Side
USB Opening
5.5. Measuring procedure
After the cuff has been appropriately positioned, the measurement can begin: a) Press the ON/OFF button. The display will show many icons followed by 3 beeps indicating "ready to measure." b) Press the ON/OFF button. The pump begins to inflate the cuff.
The rising pressure in the cuff is shown in the display of your monitor.
c) After a suitable inflation pressure has been reached, the pump stops and the pressure gradually falls. The cuff pressures are displayed. If the inflation pressure is not sufficient, the monitor automatically re-inflates.
d) When the instrument detects a pulse, the heart symbol in the display starts to flash and a beep is heard for every heartbeat.
e) A long beep is sounded when the measurement is complete. The systolic, and diastolic blood pressure, and pulse rate now appear in the display.
f) The measurement reading remains on the display until you switch off the instrument. If no button is pressed for a period of
5 minutes the instrument switches itself off in order to preserve the batteries.
g) When the unit is set to the
average mode setting,
3 separate measurements will take place in succession after which your result is calculated. There is a 15 second resting time in-between each measurement. A countdown indicates the remaining time and a beep will sound 5 seconds before the
2nd and 3rd readings will begin.
TIME
1
1 mmHg mmHg
MAM
1 mmHg mmHg
If one of the measurements causes an error message, it will be repeated one more time. If any additional error occurs, the measurement will be discontinued and error code Err 2 will be displayed.
Average
Mode
5.6. Discontinuing a measurement
If it is necessary to interrupt a blood pressure measurement for any reason (e.g. the patient feels unwell), the ON/OFF button can be pressed at any time. The device then immediately lowers the cuff pressure automatically.
Time/Date
MAM
1 mmHg mmHg
Systolic
Diastolic
Pulse
User
12
User selections
This advanced blood pressure monitor allows you to track blood pressure readings for 2 individuals independently.
a) Before taking your measurement, make sure you set the unit for the intended user. (User 1, User 2) b) The unit is preset to User 1. Press and hold the USER/TIME button until you see the user icon blinks, then press the memory button to select the user1 or user 2, and then press the Time button again to confirm c) Press the USER/TIME button again to change back to User 1.
d) After you have selected a User, wait 3 seconds and the display will stop blinking. The User is now selected.
User Selection
Note:
Before proceeding make sure the unit is turned on.
1
5.4. Measurement mode selection
Clinical studies demonstrate taking multiple blood pressure readings and calculating an “average” is more likely to determine your true blood pressure. Your ADC ® unit allows you to switch it into an
Average Mode setting that automatically takes multiple readings!
User 1 symbol
2
2
User 2 symbol
4.5. Setting the time and date
This blood pressure monitor incorporates an integrated clock with date display. Time and date are recorded along with pressure and pulse. You must enter the date and current time. Proceed as follows
(Example: Entering 2002-06-15, 09:30 AM): Turn on unit.
1. Press and hold the USER/TIME button for at least 3 seconds, the user icon will blink, after setting the user, the year characters will blink then.
2. The correct year can be entered by pressing the
MEMORY button once for each change.
(Example: 1 press for 1 year)
5. Press the USER/TIME button again. The last two characters (day) are now blinking.
6. The current day can now be entered by pressing the MEMORY button. (Example: 14 presses advances the day from the 1st to 15th)
Average mode slide switch:
a) If you would like to take an average mode measurement, move the slide switch to the right. b) Average mode takes 3 measurements in succession and calculates the result. An “MAM“ symbol in the display indicates that the unit is set to the average mode. c) There will be 15 seconds resting time in-between each measurement and an hourglass icon will appear on the display.
The unit will count down from 15 seconds. A beep will sound at the last 5 seconds to remind you that the unit is about to take another measurement.
3. Press the USER/TIME button again. The display now switches to the current date, during which the first character (month) blinks.
Note:
Holding the
“M” button down speeds up the procedure.
7. Press the USER/TIME button again. The display now switches to the current time, during which the first character (hour) blinks.
TIME
Single mode
a) If you would like to take a single mode measurement, move the slide switch to the left. b) Single mode only has 1 measurement.
4. The current month can now be entered by pressing the MEMORY button. (Example: pressing
5 x advances 5 months)
8. The corresponding hour can now be entered by pressing the MEMORY button.
(Example: 9 presses advances 9 hours)
TIME
11 8
9. Press the USER/TIME button again. The last two characters (minutes) now blink.
10. The minutes can now be entered by pressing the MEMORY button. (Example: 30 presses advances the time from 0 to 30 minutes)
4.6. Reading the set date
After all settings have been made, press the
USER/TIME button once. The date is briefly displayed and then the time. The input is now confirmed and the clock begins to run.
1
1
5. THE MEASUREMENT PROCEDURE
5.1. Before measuring:
• Avoid eating, and smoking, as well as all forms of exertion, directly before the measurement. All these factors influence the measurement result. Try and find time to relax by sitting in an armchair or lying down in a quiet atmosphere for about ten minutes before the measurement.
• Remove any garment that fits closely to your upper arm.
• Always measure on the same arm (normally left).
• Take measurements regularly at the same time of day, since blood pressure changes during the course of the day.
5.2. Common sources of error:
Note: Comparable blood pressure measurements always require the same conditions!
Conditions should always be quiet.
• All efforts by the user to support the arm can increase blood pressure. Make sure you are in a comfortable, relaxed position and do not activate any of the muscles in the measurement arm during the measurement.
Use a cushion for support if necessary.
• If the cuff lies considerably lower or higher than the heart, an erroneously high or low blood pressure will be measured! Each 15cm (6”) difference in height results in a measurement error of
10 mmHg!
• Cuffs that are too narrow or too short result in false measurement values. Selecting the correct cuff is extremely important. Cuff size is dependent upon the circumference of the arm (measured in the center).
The permissible range is printed on the cuff. If this is not suitable for your use, contact ADC ® . A larger cuff size is sold separately.
Note: Only use clinically approved ADC
®
Original Cuffs!
• A loose cuff or a protruding air pocket causes false measurement values.
• With repeated measurements, blood accumulates in the arm, which can lead to false results. Consecutive blood pressure measurements should be repeated after a 5 minute pause or after your arm has been held up in order to allow the accumulated blood to flow away (for about 3 minutes).
9
5.3. Fitting the cuff
a) Position the cuff flat on a table with the hook and loop adhesive side down. Pass the end of the cuff through the metal ring so that a loop is formed. The hook & loop closure must be facing outward. (Ignore this step if the cuff has already been prepared - Figure 1).
b) Place the cuff over the left upper arm so that the tube points in the direction of the lower arm (Figure 2).
c) Lay the cuff on the arm as illustrated. Make certain that the lower edge of the cuff lies approximately 3/4 to 1”
(2 to 3 cm) above the elbow and that the tube is closer to the inner side of the arm (Figure 3).
Important!
The 1” white bar on the cuff must lie exactly over the brachial artery, which runs down the inner side of the arm
(Figure 4).
d) Tighten the cuff by pulling on the free end and close the cuff by affixing the hook and loop closure (Figure 5).
e) The cuff should be snug on the upper arm and there should be enough space to fit 2 fingers between the arm and the cuff. Clothing must not restrict the arm; any piece of clothing that does must be removed.
Cuffs that don’t fit properly result in false measurement values. Measure your arm circumference if you are not sure of proper fit. A larger size cuff is available..
f) Lay the arm on a table (palm upward) so that the cuff is at the same height as the heart (Figure 7).
Make sure that the tube is not kinked (Figure 8).
g) Remain seated quietly for at least two minutes before you begin the measurement.
Comment:
If it is not possible to fit the cuff to the left arm, it can also be placed on the right arm. However, all future measurments should be made using the same arm.
Comparable blood pressure measurements always require the same conditions.
(Figure 1)
(Figure 2)
3/4”- 1”
(Figure 3)
(Figure 4) cuff tube
1” white mark proper cuff placement
(inside of inner arm)
(Figure 7)
(Figure 8)
(Figure 5)
(Figure 6)
10