advertisement
![Patton CopperLink 1314MDE Quick Start Manual | Manualzz Patton CopperLink 1314MDE Quick Start Manual | Manualzz](http://s3.manualzz.com/store/data/055413881_1-5b339dfa7009bc2cfd810431f81d9604-360x466.png)
CopperLink™ Model 1314MDE
Ruggedized Multi-Drop Ethernet
Extender & Repeater
Quick Start Guide
Important —This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial or residential environment.
REGULATORY MODEL NUMBER : 03340D4-001
Part Number: 07MCL1314MDE-QS, Rev. A
Revised: August 10, 2012
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: [email protected]
WWW: www.patton.com
2
WARNING
• Do not open the device when the power cord is connected. For systems without a power switch and without an external power adapter, line voltages are present within the device when the power cord is connected.
• For devices with an external power adapter, the power adapter shall be a listed Limited Power Source The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker in compliance with local regulatory requirements.
• For AC powered devices, ensure that the power cable used meets all applicable standards for the country in which it is to be installed.
• For AC powered devices which have 3 conductor power plugs (L1, L2
& GND or Hot, Neutral & Safety/Protective Ground), the wall outlet
(or socket) must have an earth ground.
• For DC powered devices, ensure that the interconnecting cables are rated for proper voltage, current, anticipated temperature, flammability, and mechanical serviceability.
• WAN, LAN & PSTN ports (connections) may have hazardous voltages present regardless of whether the device is powered ON or OFF.
PSTN relates to interfaces such as telephone lines, FXS, FXO, DSL, xDSL, T1, E1, ISDN, Voice, etc. These are known as “hazardous network voltages” and to avoid electric shock use caution when working near these ports. When disconnecting cables for these ports, detach the far end connection first.
• Do not work on the device or connect or disconnect cables during periods of lightning activity .
This device is NOT intended nor approved for connection to the PSTN. It is intended only for connection to customer premise equipment.
WARNING
In accordance with the requirements of council directive 2002/96/EC on
Waste of Electrical and Electronic Equipment (WEEE), ensure that at endof-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.
CopperLink Model 1314MDE Quick Start Guide
1.0 Configure the DIP Switches
To use DIP-switch configuration, you must first set the DIP switches to a position other than all OFF or all ON before powering-up the CopperLink. To configure your CL1314MDE using the DIP switches, refer to the section entitled “Hardware (DIP-switch) configuration” in the CopperLink Model 1314MDE User Manual.
2.0 Power up the CL1314MDE
The CL1314MDE comes with either an external AC or external DC power supply.
Figure 1. Power Supply Installation
2.1 Models with external AC adapter
To connect the AC power supply, determine the positive lead and negative lead on the power adapter. Insert the positive lead into the opening on the terminal block labeled + and the negative lead into the opening on the terminal block labeled . Tighten the screws on the block to secure the wires. The CL1314MDE powers up as soon as it is connected to an AC power source—there is no power switch.
2.2 Models with external DC power supply
The 36-60 VDC DC to DC adapter is supplied with the DC version of the CL1314MDE. The black and red leads on one end of the power supply plug into a DC source (nominal 48VDC), and the leads on the other end connect to the terminal block power connector on the CL1314MDE.
Black lead (-V)
Red lead (+V)
To Terminal Block
Power Connector
-Vin
+Vin
-Vin
+Vin
To -48VDC
Source
Black lead (-V)
Red lead (+V)
CopperLink Model 1314MDE Quick Start Guide
Figure 2. DC Power Supply
3
2.3 Power up indication
Verify that the Power LED on the front panel illuminates and remains lit.
CopperLink™ Line Port 2
CopperLink™ Port 2
Line Link LED
Ethernet Port 3
Ethernet Port 2
Ethernet Port 3 Link LED
Ethernet Port 2 Link LED
CopperLink™ Line Port 1
Power LED
CopperLink™ Port 1
Line Link LED
Ethernet Port 1
Ethernet Port 0
Ethernet Port 0 Link LED
Ethernet Port 1 Link LED
Reset button
Figure 3. CL1314MDE front panel
3.0 Connect the CopperLink interface
These units work in pairs with any CL1314 model. Every local CopperLink port should connect to a remote CopperLink port.
(CL1314R or
CL1314)
Twisted Pair
(Connect to C1)
Twisted Pair
(Connect to Local or C2 of another MDE)
(MDE, CL1314R or CL1314)
Figure 4. Local to Remote Connection
1.
Obtain single-twisted-pair cable with an RJ-45 plug connector at each end.
2.
Plug one end of the cable into the RJ-45 socket (labeled C1 or C2) on the CopperLink. Verify that the other end of the cable is connected to the Line port on other CopperLink 1314 and that the port is correctly configured.
3.
When a link is established, the Line Link LED will turn on.
4 CopperLink Model 1314MDE Quick Start Guide
4.0 Connect the Ethernet port(s)
The RJ-45 ports labeled Eth 0, Eth 1, Eth 2 , and Eth 3 are the Auto-MDIX 10/100Base-T interfaces. These ports are designed to connect directly to a 10/100Base-T device or network. You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long.
5.0 Additional information
For detailed information about installing, configuring, and operating the CopperLink, refer to the CopperLink
Model 1314MDE User Manual at www.patton.com/manuals/CL1314MDE.pdf
.
A.0 Compliance Information
A.1 Compliance
EMC:
•
FCC Part 15, Class A
•
•
EN55022, Class A
EN55024
Safety:
•
UL 60950-1/CSA C22.2 N0. 60950-1
•
IEC/EN60950-1
1.2 Radio and TV Interference (FCC Part 15)
This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception. This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).
CopperLink Model 1314MDE Quick Start Guide 5
A.3 EC Declaration of Conformity
(See section
A.4 “EG-Konformitätserklärung”
for German version.)
Product Description: CopperLink Model 1314MDE
This equipment conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of their conformity.
The safety advice in the documentation accompanying the products shall be obeyed.
The conformity to the above directive is indicated by the CE sign on the device.
The signed Declaration of Conformity can be downloaded from www.patton.com/certifications/.
A.4 EG-Konformitätserklärung
(see section A.3 “EC Declaration of Conformity”
for English version)
Produktbezeichnung : CopperLink Model 1314MDE
Die bezeichneten Produkte stimmen in der von uns in Verkehr gebrachten Ausführung mit den Vorschriften folgender Richtlinie überein:
R&TTE 1999/5/EG
Richtlinie des europäischen Parlaments und des Rates zur Angleichung der Rechtsvorschriften der
Mitgliedstaaten über Funkanlagen und Telekommunikations-Endeinrichtungen und die gegenseitige
Anerkennung ihrer Konformität.
Die Sicherheitshinweise in der mitgelieferten Produktdokumentation sind zu beachten.
Die Konformität mit der oben erwähnten Richtlinie wird durch das CE-Zeichen auf dem
Gerät bestätigt.
Die unterzeichnete Konformitätserklärung kann heruntergeladen werden von: www.patton.com/ certifications/.
A.5 Authorized European Representative
D R M Green
European Compliance Services Limited.
Oakdene House, Oak Road
Watchfield, Swindon, Wilts SN6 8TD, UK
6 CopperLink Model 1314MDE Quick Start Guide
Copyright statement
Copyright © 2012, Patton Electronics Company. All rights reserved.
The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document.
Trademarks statement
The term CopperLink is a trademark of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners.
Patton support headquarters in the USA
• Online support: Available at www.patton.com
•
E-mail support: E-mail sent to [email protected]
will be answered within 1 business day
• Telephone support: Standard telephone support is available five days a week—from 8:00 am to
5:00 pm EST ( 1300 to 2200 UTC/GMT )—by calling +1 (301) 975-1007
•
Support via VoIP: Contact Patton free of charge by using a VoIP ISP phone to call sip:[email protected]
•
Fax: +1 (253) 663-5693
Alternate Patton support for Europe, Middle East, and Africa (EMEA)
•
Telephone support: Standard telephone support is available five days a week—from 8:00 am to
5:00 pm CET ( 0900 to 1800 UTC/GMT )—by calling +41 (0)31 985 25 55
• Fax: +41 (0)31 985 25 26
Note For additional service and support information, refer to the “Contacting Patton for assistance” chapter of the CopperLink Model 1314MDE User Manual available online at www.patton.com/manuals/
CL1314MDE.pdf
.
Warranty, Trademark, & Compliance Information
For warranty, trademark and compliance information, refer to the CopperLink Model 1314MDE User Manual available online at www.patton.com/manuals/CL1314MDE.pdf
.
CopperLink Model 1314MDE Quick Start Guide 7
NOTES
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
8 CopperLink Model 1314MDE Quick Start Guide
advertisement
Related manuals
advertisement