Beckhoff CP39 -0000 Series Installation And Operating Instructions Manual
Annonce
Annonce
Installation and Operating instructions for
CP39xx-0000
Multi-touch Control Panel with DVI/ USB Extended interface
CP39xx-0010
Multi-touch Control Panel with CP-Link 4 interface
Version: 2.6
Date: 2020-01-17
Table of contents
Table of contents
1 Foreword
1.1
Notes on the Documentation
1.1.1
Liability Conditions
1.1.2
Trademarks
1.1.3
Patent Pending
1.1.4
Copyright
1.1.5
State at Delivery
1.1.6
Delivery conditions
1.2
Description of safety symbols
1.3
Basic safety measures
1.4
Operator’s obligation to exercise diligence
1.4.1
National regulations
1.4.2
Procedure in the event of a fault
1.4.3
Operator requirements
2 Product Description
2.1
Product overview
2.2
Appropriate Use
2.3
Access to the connectors
2.3.1
Fitted without mounting arm adapter
2.3.2
Fitted with mounting arm adapter
2.3.3
Installing the Cables
2.4
Interfaces CP39xx-0000
2.4.1
Power Supply (X101)
2.4.2
DVI-E Input (Digital Visual Interface-Extended) (X102)
2.4.3
USB-E Input (X 103)
2.4.4
Protective Earthing
2.5
Interfaces CP39xx-0010
2.5.1
CP-Link 4 Architecture Description
2.5.2
Interfaces
2.5.3
Power Supply (X101), optional
2.5.4
CP-Link 4 Input (X102)
2.5.5
Protective Earthing
2.6
USB interface at the mounting arm adapter (optional)
2.7
Protective Earthing
2.8
Connection Kits/ Connection Cables/Accessories
2.8.1
Connection Kit DVI-E/ USB-E connection for CP39xx-0000, optional
2.8.2
Accessories for CP39xx-0010, optional
CP39xx
7
12
12
12
13
13
10
11
8
8
7
8
14
14
16
16
17
17
18
18
19
19
19
3
4
5
6
6
6
6
3
3
3
3
3
3
3
1
Table of contents
2.8.3
Connecting cable for CP39xx-0010, optional
3 Installation
3.1
Transport and Unpacking
3.1.1
Transport
3.1.2
Unpacking
4 Mounting
4.1
Earthing measures
4.2
Mounting arm installation (optional)
4.2.1
Mounting the mounting arm tube
4.3
Connecting the Control Panel
4.3.1
Connecting cables
4.3.2
Protective Earthing
5 Operating Instructions
5.1
Switching the Control Panel on and off
5.1.1
Switching on
5.1.2
Shutting down and switching off
5.2
Operation
5.3
Servicing and maintenance
5.3.1
Cleaning
5.3.2
Maintenance
5.4
Emergency procedures
5.5
Shutting down
5.5.1
Disposal
6 Troubleshooting
7 Assembly dimensions
8 Technical Data
9 Appendix
9.1
Beckhoff Support and Service
9.1.1
Beckhoff branches and partner companies
9.1.2
Beckhoff company headquarters
9.2
Approvals for USA and Canada
9.3
FCC Approvals for the United States of America
9.4
FCC Approval for Canada
2
30
31
32
32
32
32
33
33
33
27
28
28
28
28
28
27
27
27
27
28
29
19
21
21
21
21
22
22
23
24
26
26
26
CP39xx
Foreword
1 Foreword
1.1 Notes on the Documentation
This description is only intended for the use of trained specialists in control and automation engineering who are familiar with the applicable national standards. It is essential that the following notes and explanations are followed when installing and commissioning these components.
The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards.
1.1.1 Liability Conditions
The documentation has been prepared with care. The products described are, however, constantly under development. For that reason the documentation is not in every case checked for consistency with performance data, standards or other characteristics. In the event that it contains technical or editorial errors, we retain the right to make alterations at any time and without warning. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation.
All pictures shown in the documentation are exemplary. Illustrated configurations can differ from standard.
1.1.2 Trademarks
Beckhoff ® , TwinCAT ® , EtherCAT ® , EtherCAT P ® , Safety over EtherCAT ® , TwinSAFE ® , XFC ® and XTS ® are registered trademarks of and licensed by Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners.
1.1.3 Patent Pending
The EtherCAT Technology is covered, including but not limited to the following patent applications and patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications or registrations in various other countries.
The TwinCAT Technology is covered, including but not limited to the following patent applications and patents: EP0851348, US6167425 with corresponding applications or registrations in various other countries.
1.1.4 Copyright
© Beckhoff Automation GmbH & Co. KG.
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization are prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
1.1.5 State at Delivery
All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG.
1.1.6 Delivery conditions
In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co. KG apply.
CP39xx 3
Foreword
1.2 Description of safety symbols
The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions.
Acute risk of injury!
DANGER
If you do not adhere the safety advise adjoining this symbol, there is immediate danger to life and health of individuals!
Risk of injury!
WARNING
If you do not adhere the safety advise adjoining this symbol, there is danger to life and health of individuals!
Hazard to individuals!
CAUTION
If you do not adhere the safety advise adjoining this symbol, there is obvious hazard to individuals!
Hazard to devices and environment
Attention
If you do not adhere the notice adjoining this symbol, there is obvious hazard to materials and environment.
Note or pointer
This symbol indicates information that contributes to better understanding.
Note
4 CP39xx
Foreword
1.3 Basic safety measures
Before the Industrial PC is switched off, software that is running must be properly closed.
Otherwise it is possible that data on the storage medium is lost. Please read the section Switching the
Control Panel on and off .
Switch off all parts of the equipment, then uncouple the Control Panel
Warning
Before opening the housing, and whenever the Control Panel is not being used for control purposes (such as during functional checks after a repair), all parts of the equipment must first be switched off, after which the Control Panel is to be disconnected from the equipment.
Disconnect the device by unplugging the connectors on the rear side of the Control Panel.
Items of equipment that have been switched off must be secured against being switched on again.
Do not exchange any parts when under power
Warning
When components are being fitted or removed, the supply voltage must be switched off.
Fitting work on the Control Panel can result in damage:
• if metal objects such as screws or tools fall onto operating circuit boards
• if connecting cables internal to the Panel PC are removed or inserted during operation.
CP39xx 5
Foreword
1.4 Operator’s obligation to exercise diligence
The operator must ensure that
• the product is only used as intended (see chapter Product Description )
• the product is in a sound condition and in working order during operation
• the product is operated, maintained and repaired only by suitably qualified and authorized personnel
• the personnel is instructed regularly about relevant occupational safety and environmental protection aspects, and is familiar with the operating manual and in particular the safety notes contained herein
• the operation manual is in good condition and complete, and always available for reference at the location of the product.
Do not open the housing of the Control Panel!
For technical support contact Beckhoff Service .
Note
1.4.1 National regulations
Depending on the type of machine and plant in which the Control Panel is used, national regulations governing the controllers of such machines will apply, and must be observed by the operator. These regulations cover, amongst other things, the intervals between inspections of the controller. The operator must initiate such inspections in good time.
1.4.2 Procedure in the event of a fault
In the event of faults at the Control Panel, the list in the section Troubleshooting can be used to determine the measures to be taken.
1.4.3 Operator requirements
Anyone who uses the Control Panel must have read these operating instructions and must be familiar with all the functions of the software installed on the Industrial PC to which he has access.
6 CP39xx
2 Product Description
2.1 Product overview
Front view of CP39xx
Product Description
The new Beckhoff panel generation with industry-standard multi-touch display offers a feature-laden solution for any application. The wide selection of models offers different display sizes and formats as well as custom designs. Even for single-touch users, this new panel generation offers an excellent priceto-performance ratio and represents an economical alternative to other systems.
The multi-touch Control Panel offer the following benefits:
• display sizes from 7-inch to 24-inch (16:9, 5:4, 4:3), landscape and portrait orientation
• multi-touch (PCT): e.g. for 5-finger or 2-hand touch operation
• high touch-point density for safe operation
• aluminium housing with glass front, IP65
• CP39xx-0000 with integrated DVI/USB extension technology:
– DVI-E and USB-E 2.0 enable remote panel operation at a distance of up to 50 m from the PC
– USB-E 2.0 transmits USB 2.0 with 480 Mbit/s
– DVI-E input is compatible to the standard DVI output of a PC
• CP39xx-0010 with CP-Link 4 technology:
– enables remote panel operation at a distance of up to 100 m from the PC via a Cat.6
A cable
– integrated or separate 24 V DC power supply
– CP-Link 4 transmits USB 2.0 with 100 MBit/s
• optional 1-Port-USB interface at the mounting arm adapter
• optional electromechanical push-button extension
• optional mounting arm system.
CP39xx 7
Product Description
2.2 Appropriate Use
The multi-touch Control Panel CP39xx is designed for industrial application in machine and plant engineering. A multi-touch display is accommodated in a stainless steel housing. For mounting the
Control Panel there are 4 threaded holes M6 in the connection block at the rear cover.
Optionally rotatable and tiltable mounting arm adapters are available for installation with 48 mm tubes from the bottom or from the top, see chapter Mounting arm installation (optional) .
The DVI/USB extension technology integrated in the CP39xx-0000 Control Panel enables remote Panel operation at a distance of up to 50 m from the PC via a standard cable.
The CP-Link 4 connection technology integrated in the CP39xx-0010 Control Panel enables remote panel operation at a distance of up to 100 m from the PC via a Cat.6A cable with integrated or separate
24 V DC power supply depending on the transmitter module.
Risk of explosion!
Danger
The Control Panel must not be used where there is a risk of explosion.
2.3 Access to the connectors
2.3.1 Fitted without mounting arm adapter
The connectors of the Control Panel are located in the connection block at the rear side of the housing.
The connectors will be plugged from the bottom.
Connection block CP39xx-0000
For the pin assignment see chapter Interfaces CP39xx-0000 .
8 CP39xx
Connection block CP39xx-0010
Product Description
For the pin assignment see chapter Interfaces CP39xx-0010 .
CP39xx 9
Product Description
2.3.2 Fitted with mounting arm adapter
If the Control Panel is fitted with a mounting arm adapter (order option C9900-M750 to C9900-M753), the connectors are located behind the cover ( 1 ).
1
For removing first unlatch the cover ( 1 ) carefully at the two notches (see arrows) using a suitable tool
(e.g. screwdriver).
You can now lever up the cover in direction of the arrow. After removing the cover you have access to the connections.
The installation of the cover takes place in reverse order.
10 CP39xx
Product Description
2.3.3 Installing the Cables
After opening the connection area you have access to the connections of the Control Panel. The cables with the connectors have to be threaded through the mounting arm tube before connecting them in the connection area.
Note cable routing
Attention
It is absolutely necessary to install the cables as shown in the picture. Otherwise cables can be damaged by rotating or tilting the mounting arm adapter.
CP39xx-0000 power supply cable installation outside data cable installation inside
CP39xx-0010 cable installation inside
CP39xx 11
Product Description
2.4 Interfaces CP39xx-0000
X103
USB-E Input
2.4.1 Power Supply (X101)
X102
DVI-E Input
X101
Power Supply
Ground
X101
SG 4-pole M12 built-in-PCB-sold. IP67 BINDER (BINDER 09-3431-90-04 prod. 763 M12X1)
View solder connection sided
The power supply for the Control Panel is established via the 4-pole M12 socket (X101).
The protection class of the circular plug-in connector accords to the IP65-standard.
Pin
1
2
Signal
+ 24V
GND
Pin
3
4
Signal
GND
+ 24V
2.4.2 DVI-E Input (Digital Visual Interface-Extended) (X102)
G
H
I
K
Pin
A
B
C
D
E
F
12
X102
SG 19-pole M16 built-in-PCB-sold. IP67 BINDER (BINDER 09-0463-90-19 prod. 723 M16X0,75)
View solder connection sided
The DVI-E connection (X102) is used for transferring the video signal from the Industrial PC to the Control
Panel. The protection class of the circular plug-in connector accords to the IP65-standard.
The graphics signal is transferred directly via a DVI cable over a distance of 50 m max. Such a cable length leads to strong distortion of the graphics signal on arrival at the Control Panel. The CP39xx Control
Panel features a signal processor that restores the DVI signal. The PC requires a conventional DVI output.
Signal
Shield
IN_TMDS_2+
GND
IN_TMDS_1-
GND
IN_TMDS_0-
GND
+ 5V_DVI
DDC DAT
I2C-CLK
S
T
U
Pin
L
M
N
O
P
R
Signal
IN_TMDS_C+
GND
IN_TMDS_2-
IN_TMDS_1+
GND
IN_TMDS_0+
HPD_DVI
GND
IN_TMDS_C-
CP39xx
Product Description
2.4.3 USB-E Input (X 103)
6
7
8
3
4
5
Pin
1
2
X103
SG 8-pole M9 built-in-PCB-sold. IP67 BINDER (BINDER 09-0427-30-08 prod. 712 M9X0,5)
View solder connection sided
The Control Panel is connected with the CU8801 USB to USB extended converter box via the USB-
Extended input (X103).
The protection class of the circular plug-in connector accords to the IP65standard.
In order to realize a distance of 50 m without hubs, with USB extended the USB signal is converted so that it can be transferred via 50 m CAT5 cables commonly used for Ethernet wiring. In the Control Panel the signal is converted back to USB.
Signal
15 V
GND
Tx
RX
RX
Tx
15 V
GND
Pin assignment
15V USB_E
GND
USB Rx+
USB Tx+
USB Tx-
USB Rx-
15V USB_E
GND
2.4.4 Protective Earthing
The low resistance protective earthing connection of the Control Panel is established via the ground bolt, which is located next to the connections or in the connection area (if provided with a mounting arm adapter).
CP39xx 13
Product Description
2.5 Interfaces CP39xx-0010
2.5.1 CP-Link 4 Architecture Description
2.5.1.1 CP-Link 4 – The Two Cable Display Link
The CP39xx-0010 multi-touch panels can be operated up to 100 m away from the PC. CP-Link 4 transfers DVI and USB together via a CAT.6
A
cable. The CU8802 CP-Link 4 transmitter box is connected to the PC via DVI and USB, or else the C9900-E276 PCIe module for CP-Link 4 is installed in the PC.
CP-Link 4 – The Two Cable Display Link via the CU8802 transmitter box
CP-Link 4 – The Two Cable Display Link via the C9900-E276 PCIe module
14 CP39xx
Product Description
2.5.1.2 CP-Link 4 – The One Cable Display Link
The power supply for the Control Panel can also be provided via CP-Link 4. The CU8803 CP-Link 4 transmitter box is used instead of the CU8802 or the PCIe module. The Control Panel remains unchanged. The CU8803 sender box provides power to the Control Panel via the CAT.6
A
cable, which also transfers DVI and USB. The power supply socket of the panel is not used.
Don’t connect power supply socket if using One Cable technology
Attention
If using the CP-Link 4 - One Cable Display Link technology, do not connect anything to the power supply socket of the Panel.
CP-Link 4 – The One Cable Display Link via the CU8803 transmitter box
CP39xx 15
Product Description
2.5.2 Interfaces
X102
CP-Link 4 Input
2.5.3 Power Supply (X101), optional
X101
Power Supply
Ground
X101
SG 4-pole M12 built-in-PCB-sold. IP67 BINDER (BINDER 09-3431-90-04 prod. 763 M12X1)
View solder connection sided
The power supply for the Control Panel is established via the 4-pole M12 socket (X101).
The protection class of the circular plug-in connector accords to the IP65-standard.
Pin
1
2
Signal
+ 24V
GND
Pin
3
4
Signal
GND
+ 24V
Don’t connect power supply socket if using One Cable technology
Attention
If using the CP-Link 4 - One Cable Display Link technology, do not connect anything to the power supply socket of the Panel.
If using the CP-Link 4 - One Cable Display Link technology, the circular plug-in connector is covered with the provided cap.
16 CP39xx
Product Description
2.5.4 CP-Link 4 Input (X102)
X102
SG 8pole M12 build-in-IP67 METZ connect CAT6A
3
4
1
2
5
6
The Control Panel is connected with the PCIe module slot of the Industrial PC or the transmitter box
CU8802/ CU8803 via the CP-Link 4 Input ( X 102 ).
Pin Signal Pin Signal
HDBT_0P
HDBT_0N
HDBT_1P
HDBT_1N
HDBT_3P
HDBT_3N
7
8
S1
S2
S3
HDBT_2N
HDBT_2P
Shield
Shield
Shield
CU8803-0000 disconnect power supply
Attention
If using the CP-Link 4 - One Cable Display Link, the 24 V power supply of the CP-Link 4 transmitter box must be switched off before disconnecting the CP-Link 4 output connection.
2.5.5 Protective Earthing
The low resistance protective earthing connection of the Control Panel is established via the ground bolt, which is located next to the connections or in the connection area (if provided with a mounting arm adapter).
CP39xx 17
Product Description
2.6 USB interface at the mounting arm adapter (optional)
Optionally the Control Panel is fitted with a USB-2.0 Interface (order option C9900-E274).
The interface is located at the mounting arm adapter behind a screw cap, the protection class accords to the IP65-standard.
USB Interface
2.7 Protective Earthing
The low resistance protective earthing connection of the Control Panel is established via the ground bolt, which is located next to the connections or in the connection area (if provided with a mounting arm adapter).
Note
Malfunction possible with missing ground connection
A proper ground connection of the device is absolutely necessary for the correct function of the touchscreen.
18 CP39xx
Product Description
2.8 Connection Kits/ Connection Cables/Accessories
One 4-pole power supply connector is provided with the Control Panel.
2.8.1 Connection Kit DVI-E/ USB-E connection for CP39xx-0000, optional
Optionally prefabricated connection cables for the DVI-E/ USB-E connection are available.
Connection kit
C9900-K630
C9900-K631
C9900-K632
C9900-K633
C9900-K634
C9900-K635
C9900-K636
DVI-E/ USB-E connection
Connection kit 3 m for CP39xx including:
3 m DVI cable, 3 m CAT5 cable for USB-E-2.0, USB to USB-E-2.0 converter CU8801 for mounting rail installation close to the PC and 1 m USB cable to connect the USB to USB-E-2.0 converter to the PC
Connection kit 5 m for CP39xx including:
5 m DVI cable, 5 m CAT5 cable for USB-E-2.0, USB to USB-E-2.0 converter CU8801 for mounting rail installation close to the PC and 1 m USB cable to connect the USB to USB-E-2.0 converter to the PC
Connection kit 10 m for CP39xx including:
10 m DVI cable, 10 m CAT5 cable for USB-E-2.0, USB to USB-E-2.0 converter CU8801 for mounting rail installation close to the PC and 1 m USB cable to connect the USB to USB-E-2.0 converter to the PC
Connection kit 20 m for CP39xx including:
20 m DVI cable, 20 m CAT5 cable for USB-E-2.0, USB to USB-E-2.0 converter CU8801 for mounting rail installation close to the PC and 1 m USB cable to connect the USB to USB-E-2.0 converter to the PC
Connection kit 30 m for CP39xx including:
30 m DVI cable, 30 m CAT5 cable for USB-E-2.0, USB to USB-E-2.0 converter CU8801 for mounting rail installation close to the PC and 1 m USB cable to connect the USB to USB-E-2.0 converter to the PC
Connection kit 40 m for CP39xx including:
40 m DVI cable, 40 m CAT5 cable for USB-E-2.0, USB to USB-E-2.0 converter CU8801 for mounting rail installation close to the PC and 1 m USB cable to connect the USB to USB-E-2.0 converter to the PC
Connection kit 50 m for CP39xx including:
50 m DVI cable, 50 m CAT5 cable for USB-E-2.0, USB to USB-E-2.0 converter CU8801 for mounting rail installation close to the PC and 1 m USB cable to connect the USB to USB-E-2.0 converter to the PC
2.8.2 Accessories for CP39xx-0010, optional
The following accessories are available:
Accessories
CU8802-0000
CU8803-0000
C9900-E276 for CP-Link 4
Transmitter box for CP-Link 4 – The Two Cable Display Link
CP-Link 4 Extender Tx for connecting a Control Panel with CP-Link 4 interface CP29xx-0010 or
CP39xx-0010
Transmitter box for CP-Link 4 – The One Cable Display Link
CP-Link 4 Extender Tx for connecting a Control Panel with CP-Link 4 interface CP29xx-0010 or
CP39xx-0010
PCIe module for CP-Link 4 – The Two Cable Display Link
CP-Link 4 Extender Tx PCIe module
2.8.3 Connecting cable for CP39xx-0010, optional
The following connection cables are available:
Accessories Cable for CU880x
C9900-K667 Connecting cable RJ45, Cat.6A, 3 m, one end with IP 65 connector for Control Panel CP39xx-0010
CP39xx 19
Product Description
C9900-K652 Connecting cable RJ45, Cat.6A, 5 m, one end with IP 65 connector for Control Panel CP39xx-0010
C9900-K653 Connecting cable RJ45, Cat.6A, 10 m, one end with IP 65 connector for Control Panel CP39xx-0010
C9900-K654 Connecting cable RJ45, Cat.6A, 20 m, one end with IP 65 connector for Control Panel CP39xx-0010
C9900-K655 Connecting cable RJ45, Cat.6A, 30 m, one end with IP 65 connector for Control Panel CP39xx-0010
C9900-K656 Connecting cable RJ45, Cat.6A, 40 m, one end with IP 65 connector for Control Panel CP39xx-0010
C9900-K657 Connecting cable RJ45, Cat.6A, 50 m, one end with IP 65 connector for Control Panel CP39xx-0010
C9900-K658 Connecting cable RJ45, Cat.6A, 60 m, one end with IP 65 connector for Control Panel CP39xx-0010
C9900-K659 Connecting cable RJ45, Cat.6A, 70 m, one end with IP 65 connector for Control Panel CP39xx-0010
C9900-K660 Connecting cable RJ45, Cat.6A, 80 m, one end with IP 65 connector for Control Panel CP39xx-0010
C9900-K661 Connecting cable RJ45, Cat.6A, 90 m, one end with IP 65 connector for Control Panel CP39xx-0010
C9900-K662 Connecting cable RJ45, Cat.6A, 100 m, one end with IP 65 connector for Control Panel CP39xx-
0010
C9900-K724 Connecting cable RJ45, Cat.6A, 3 m, one end with IP 65 connector for Control Panel CP39xx-0010, suitable as trailing cable
C9900-K704 Connecting cable RJ45, Cat.6A, 5 m, one end with IP 65 connector for Control Panel CP39xx-0010, suitable as trailing cable
C9900-K705 Connecting cable RJ45, Cat.6A, 10 m, one end with IP 65 connector for Control Panel CP39xx-0010, suitable as trailing cable
C9900-K706 Connecting cable RJ45, Cat.6A, 20 m, one end with IP 65 connector for Control Panel CP39xx-0010, suitable as trailing cable
C9900-K707 Connecting cable RJ45, Cat.6A, 30 m, one end with IP 65 connector for Control Panel CP39xx-0010, suitable as trailing cable
C9900-K708 Connecting cable RJ45, Cat.6A, 40 m, one end with IP 65 connector for Control Panel CP39xx-0010, suitable as trailing cable
C9900-K709 Connecting cable RJ45, Cat.6A, 50 m, one end with IP 65 connector for Control Panel CP39xx-0010, suitable as trailing cable
C9900-K710 Connecting cable RJ45, Cat.6A, 60 m, one end with IP 65 connector for Control Panel CP39xx-0010, suitable as trailing cable
C9900-K711 Connecting cable RJ45, Cat.6A, 70 m, one end with IP 65 connector for Control Panel CP39xx-0010, suitable as trailing cable
C9900-K712 Connecting cable RJ45, Cat.6A, 80 m, one end with IP 65 connector for Control Panel CP39xx-0010, suitable as trailing cable
20 CP39xx
Installation
3 Installation
3.1 Transport and Unpacking
The specified storage conditions must be observed (see chapter Technical Data ).
3.1.1 Transport
Despite the robust design of the unit, the components are sensitive to strong vibrations and impacts.
During transport, your Control Panel should therefore be protected from excessive mechanical stress.
Therefore, please use the original packaging.
Danger of damage to the unit
Attention
If the device is transported in cold weather or is exposed to extreme variations in temperature, make sure that moisture (condensation) does not form on or inside the device.
Prior to operation, the unit must be allowed to slowly adjust to room temperature. Should condensation occur, a delay time of approximately 12 hours must be allowed before the unit is switched on.
3.1.2 Unpacking
Proceed as follows to unpack the unit:
1. Remove packaging.
2. Do not discard the original packaging. Keep it for future relocation.
3. Check the delivery for completeness by comparing it with your order.
4. Please keep the associated paperwork. It contains important information for handling the unit.
5. Check the contents for visible shipping damage.
If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service.
CP39xx 21
Mounting
4 Mounting
The Control Panel will be mounted with 4 threaded screws M6 at the connection block at the rear cover
(see chapter Assembly dimensions ).
Optionally the assemblage occurs by using the mounting arm adapter (order option).
The ambient conditions specified for operation must be observed (see chapter Technical Data ).
Please note the following points during installation of the Control Panel:
• Position the Control Panel in such a way that reflections on the screen are avoided as far as possible.
• Use the position of the screen as a guide for the correct installation height; it should be optimally visible for the user at all times.
• The Control Panel should not be exposed to direct sunlight.
Avoid extreme environmental conditions
Attention
Extreme environmental conditions should be avoided as far as possible. Protect the
Control Panel from dust, moisture and heat.
4.1 Earthing measures
Earthing connections dissipate interference from external power supply cables, signal cables or cables to peripheral equipment. Establish a low-impedance connection from the earthing point on the Control Panel housing (see chapter Protective Earthing ) to the central earthing point on the control cabinet wall, in which the Panel is being installed.
Note
Malfunction possible with missing ground connection
A proper ground connection of the device is absolutely necessary for the correct function of the touchscreen.
22 CP39xx
Mounting
4.2 Mounting arm installation (optional)
The mounting arm adapter is designed for Rittal- and Rolec mounting arm systems with 48 mm tubes.
Depending on the order option the mounting arm can be installed from the bottom or from the top.
Order-Option
C9900-M750
C9900-M751
C9900-M752
C9900-M753
Description
Rotatable and tiltable mounting arm adapter at the Control Panel CP3912 to CP3924 for Rittal- and Rolec mounting arm systems with 48 mm tube from the top
Rotatable and tiltable mounting arm adapter at the Control Panel CP3912 to CP3924 for Rittal- and Rolec mounting arm systems with 48 mm tube from the bottom
Rotatable and tiltable mounting arm adapter at the Control Panel CP3912 to CP3924 with pushbutton extension for Rittal- and Rolec mounting arm systems with 48 mm tube from the top
Rotatable and tiltable mounting arm adapter at the Control Panel CP3912 to CP3924 with pushbutton extension for Rittal- and Rolec mounting arm systems with 48 mm tube from the bottom
Tolerance of the mounting arm tube diameter
Note
The mounting arm tube must have a diameter of 48 mm with a maximum tolerance of
–0.1 mm/ +0.8 mm.
The mounting arm adapter enables to tilt the Control Panel at +/- 20° and to rotate it about +/- 165°.
Anti-twist protection
Note
The mounting arm adapter is fitted with an anti-twist safeguard to avoid over winding the Control Panel and damaging the connecting cables.
Tightening the locating screw with star knob ( 1 ) will protect the Control Panel against distortion. The hook wrench ( 2 ) and the 3 mm Allen key ( 3 ) are required for installation of the mounting arm tube at the mounting arm adapter.
Order Number Description
C9900-Z263 Hook wrench size 58 – 62 for tying up the slotted nut of the mounting arm adapter
C9900-M75x
1
2
3
CP39xx 23
Mounting
4.2.1 Mounting the mounting arm tube
For mounting the mounting arm tube proceed as follows:
1. Unscrew the Allen locking screw ( 1 ) a few turns.
1
2. After feeding the connection cables of the Control Panel through the mounting arm tube, the mounting arm tube will be positioned into the mounting arm adapter
Insert the mounting arm tube all the way to the stop
Attention
The mounting arm tube has to extend into the adapter all the way to the stop, make sure the locking screw is turned out enough.
24 CP39xx
3. Tighten the Allen locking screw using the Allen key ( 2 ).
Mounting
2
4. Now the screw cap is tightened carefully clockwise, using the hook wrench SW 58-62 ( 3 ).
3
CP39xx 25
Mounting
4.3 Connecting the Control Panel
The mains plug must be disconnected
Attention
Please read the documentation for the external devices prior to connecting them!
During thunderstorms, plug connector must neither be inserted nor removed!
When disconnecting a plug connector, always handle it at the plug. Do not pull the cable!
CU8803-0000 disconnect power supply
Attention
If using the CP-Link 4 - One Cable Display Link, the 24 V power supply of the CP-Link 4 transmitter box must be switched off before disconnecting the CP-Link 4 output connection.
4.3.1 Connecting cables
The connections are located at the rear of the Control Panel and are documented in the chapter Access to the connectors .
When connecting cables to the Control Panel, please adhere to the following order:
• Disconnect the Control Panel from the power supply.
• Connect all cables at the Control Panel and at the devices to be connected.
• Ensure that all screw connections between connectors and sockets are tight!
• Reconnect all devices to the power supply.
4.3.2 Protective Earthing
The low resistance protective earthing connection of the Control Panel is established via the screw connection, which is located in the connection area.
Note
Malfunction possible with missing ground connection
A proper ground connection of the device is absolutely necessary for the correct function of the touchscreen.
26 CP39xx
Operating Instructions
5 Operating Instructions
5.1 Switching the Control Panel on and off
5.1.1 Switching on
The Control Panel does not have its own mains power switch. As soon as the power supply is switched on the Control Panel is activated.
5.1.2 Shutting down and switching off
Control software such as is typically used on Industrial PCs permits various users to be given different rights. A user who may not close software may also not switch the Industrial PC off, since data can be lost from the storage medium by switching off while software is running.
First shut down, then switch off!
Warning
If the Industrial PC is switched off as the software is writing a file to the storage medium, the file will be destroyed. Control software typically writes something to the storage medium every few seconds, so that the probability of causing damage by switching off while the software is running is very high.
Switch off power supply
Warning
When you have shut down the Industrial PC, you have to switch off power supply for at least 10 seconds before rebooting the system.
After resetting power supply the Industrial PC will start booting automatically.
5.2 Operation
The operation of the Control Panel occurs via the Touch Screen.
Risk of damaging the Touch Screen
Warning
The touch screen may only be actuated by finger tips or with the touch screen pen. The operator may wear gloves but there must be no hard particles such as metal shavings, glass splinters embedded in the glove.
Properly installation of the system and the multi-touch device
Warning
Capacitive Touch Screens use the functional principle of capacitive alternation of the electrical field. Strong electrical fields can influence the functionality of the multi-touch devices.
To ensure the correct function of the Touch Screen take care of a standardized installation of all parts of the system and an EMC-environment conforming to standards.
CP39xx 27
Operating Instructions
5.3 Servicing and maintenance
5.3.1 Cleaning
Disconnect power supply
DANGER
Switch off the device and all connected devices, and disconnect the device from the power supply.
The device can be cleaned with a soft, damp cleaning cloth. Do not use any aggressive cleaning materials, thinners, scouring material or hard objects that could cause scratches.
5.3.2 Maintenance
The Control Panel is maintenance-free.
5.4 Emergency procedures
In case of fire, the Control Panel should be extinguished with powder or nitrogen.
5.5 Shutting down
5.5.1 Disposal
Observe national electronics scrap regulations
Observe the national electronics scrap regulations when disposing of the device.
Note
In order to dispose of the device, it must be removed and fully dismantled:
• Housing components (polycarbonate, polyamide (PA6.6)) are suitable for plastic recycling.
• Metal parts can be sent for metal recycling.
• Electronic parts such as disk drives and circuit boards must be disposed of in accordance with national electronics scrap regulations.
28 CP39xx
Troubleshooting
6 Troubleshooting
Note
Pixel errors
Pixel errors in the TFT display are production-caused and represent no complaintreason!
Anomalies of the Touchscreen
Note
Fault
Anomalies of the touchscreen sensor are production-caused and represent no complaint-reason!
The Control Panel shows no function
Cause
No power supply to the Control
Panel/ Industrial PC
Measures
Check power supply cable
1. Correctly connect cable
2. Call Beckhoff Service
Computer boots, software starts, but control does not operate correctly
Malfunction of the touchscreen
Cable not connected
Cause of the fault is either in the software or in parts of the plant outside the Industrial PC
Bad or missing ground connection of the device
Call the manufacturer of the machine or the software
Establish ground connection
USB error while TwinCAT access via USB
Bad or missing ground connection of the user
Cycle time in TwinCAT is set on
10 ms (standard)
The Control Panel functions only partially or only part of the time, e.g. no or dark picture
Faulty backlight in the display
Defective components in the
Control Panel
User must stand on the floor with ordinary shoes
Increase the cycle time up to
50 ms till 80 ms
Call Beckhoff Service
Call Beckhoff Service
CP39xx 29
Assembly dimensions
7 Assembly dimensions
For the assembly dimensions of the Control Panels please visit our homepage. Here you will find the actual drawings using the link: http://download.beckhoff.com/download/Technical_Drawings/Industrial_PC/Control_Panel/CP39xx
Notice mounting orientation
Warning
The assembly of the unit must take place with the orientation diagrammed here.
30 CP39xx
Technical Data
8 Technical Data
Risk of explosion!
Danger
Note
Do not use the Control Panel in areas of explosive hazard!
Pixel errors
Pixel errors in the TFT display are production-caused and represent no complaintreason!
Anomalies of the Touchscreen
Note
Product name
Anomalies of the touchscreen sensor are production-caused and represent no complaint-reason!
Dimensions (B x H x T)
Weight approx.
(with connection block/ with mounting arm adapter)
CP39xx-0000/ -0010
See chapter Assembly dimensions
CP3907: 1.8 kg
CP3912: 3.4 kg/ 4.2 kg
CP3913: 3.1 kg/ 3.9 kg
CP3915: 3.9 kg/ 4.7 kg
CP3916: 4.5 kg/ 5.3 kg
CP3918:
CP3919:
CP3921:
CP3924:
5.5 kg/ 6.3 kg
6.1 kg/ 6.9 kg
6.6 kg/ 7.4 kg
7.6 kg/ 8.4 kg
Supply voltage
Power consumption
UL-compliance
CP39xx-0000:
Integrated DVI/USB extension technology
CP39xx-0010:
Integrated CP-Link 4 technology
24 V
DC
(20.4 – 28.8 V
DC
)
CP3907:
CP3912:
CP3913:
CP3915:
CP3916: max. 12 W max. 16 W max. 11 W max. 20 W max. 22 W
CP3918:
CP3919:
CP3921:
CP3924:
• Using a power supply class 2 or
• Fuse protection with 4 A, according to UL 60950.2 chapter 2.5, table 2C max. 25 W max. 25 W max. 35 W max. 45 W
• DVI-E and USB-E 2.0 enable remote panel operation at a distance of up to 50 m from the PC
• USB-E 2.0 transmits USB 2.0 with 480 Mbit/s
• DVI-E input is compatible to the standard DVI output of a PC
• enables remote panel operation at a distance of up to 100 m from the PC via a Cat.6
A cable
• integrated or separate 24 V DC power supply
• CP-Link 4 transmits USB 2.0 with 100 MBit/s
1-Port-USB-2.0 interface at the mounting arm adapter Optional interface
Protection class
Shock resistance
(Sinusoidal vibration)
Shock resistance (Shock)
EMC compatibility
Front side IP65, rear side IP65
EN 60068-2-6: 10 to 58 Hz:
58 to 500 Hz:
0.035 mm
0.5 G (~ 5 m/ s 2 )
EN 60068-2-27: 5 G (~ 50 m/ s
Resistance to interference
2 ), duration: 30 ms conforms to EN 61000-6-2
EMC compatibility Emission of interference conforms to EN 61000-6-4
Permissible ambient temperature 0°C to +55°C (operation)
-25°C to +65°C (transport/ storage)
Permissible relative humidity
Transport and storage
Certifications to 95%, no condensation
The same values for atmospheric humidity and shock resistance are to be observed during transport and storage as in operation. Suitable packaging of the Panel PC can improve the resistance to impact during transport.
CE; UL Listed
CP39xx 31
Appendix
9 Appendix
9.1 Beckhoff Support and Service
Beckhoff and their partners around the world offer comprehensive support and service, making available fast and competent assistance with all questions related to Beckhoff products and system solutions.
9.1.1 Beckhoff branches and partner companies
Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products!
The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com
. You will also find further documentation for Beckhoff components there.
9.1.2 Beckhoff company headquarters
Beckhoff Automation GmbH & Co. KG
Huelshorstweg 20
33415 Verl
Germany
Phone:
Fax:
E-mail:
Web:
+ 49 (0) 5246/963-0
+ 49 (0) 5246/963-198 [email protected]
http://www.beckhoff.de/
Beckhoff Support
Support offers you comprehensive technical assistance, helping you not only with the application of individual Beckhoff products, but also with other, wide-ranging services:
• world-wide support
• design, programming and commissioning of complex automation systems
• and extensive training program for Beckhoff system components
Hotline:
Fax:
E-mail:
+ 49 (0) 5246/963-157
+ 49 (0) 5246/963-9157 [email protected]
Beckhoff Service
The Beckhoff Service Center supports you in all matters of after-sales service:
• on-site service
• repair service
• spare parts service
• hotline service
Hotline:
Fax:
E-mail:
+ 49 (0) 5246/963-460
+ 49 (0) 5246/963-479 [email protected]
If servicing is required, please quote the project number of your product.
32 CP39xx
Appendix
9.2 Approvals for USA and Canada
9.3 FCC Approvals for the United States of America
FCC: Federal Communications Commission Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Technical modifications
Technological changes to the device may cause the loss of the FCC approval.
Note
9.4 FCC Approval for Canada
FCC: Canadian Notice
This equipment does not exceed the Class A limits for radiated emissions as described in the Radio
Interference Regulations of the Canadian Department of Communications.
CP39xx 33
Download
Annonce