Juniper MX960, mx960 3D Hardware Manual
Reklama
Reklama
MX960 3D Universal Edge Router Hardware Guide
Modified: 2017-06-28
Copyright © 2017, Juniper Networks, Inc.
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, California 94089
USA
408-745-2000 www.juniper.net
Copyright © 2017, Juniper Networks, Inc. All rights reserved.
Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the United
States and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
MX960 3D Universal Edge Router Hardware Guide
Copyright © 2017, Juniper Networks, Inc.
All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at http://www.juniper.net/support/eula.html
. By downloading, installing or using such software, you agree to the terms and conditions of that EULA.
ii Copyright © 2017, Juniper Networks, Inc.
Table of Contents
Documentation and Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxv
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . xxviii
Errata with the MX960 Router Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Chassis Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
MX960 Router Hardware and CLI Terminology Mapping . . . . . . . . . . . . . . . . . . . . 12
MX960 Alarm Relay Contacts on the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . 15
MX960 Alarm LEDs and Alarm Cutoff/Lamp Test Button . . . . . . . . . . . . . . . . . . . 16
MX960 Component LEDs on the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
MX960 Host Subsystem LEDs on the Craft Interface . . . . . . . . . . . . . . . . . . . 17
MX960 Power Supply LEDs on the Craft Interface . . . . . . . . . . . . . . . . . . . . . . 17
MX960 DPC and MPC LEDs on the Craft Interface . . . . . . . . . . . . . . . . . . . . . 18
MX960 FPC LEDs on the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
MX960 SCB LEDs on the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
MX960 Fan LEDs on the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 23
Copyright © 2017, Juniper Networks, Inc.
iii
MX960 3D Universal Edge Router Hardware Guide
MX960 RE-S-1300 and RE-S-2000 Routing Engine LEDs . . . . . . . . . . . . . . . . . . . 31
RE-S-1800 Routing Engine Description for MX Series . . . . . . . . . . . . . . . . . . . . . . 31
RE-S-1800 Routing Engine Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
RE-S-1800 Routing Engine Boot Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . 33
RE-S-X6-64G Routing Engine Components . . . . . . . . . . . . . . . . . . . . . . . . . . 34
RE-S-X6-64G Routing Engine Boot Sequence . . . . . . . . . . . . . . . . . . . . . . . . 35
MX5, MX10, MX40, and MX80 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . 43
MX2020 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
TX Matrix Plus (with 3D SIBs) Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . 51
iv Copyright © 2017, Juniper Networks, Inc.
Table of Contents
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
MX960 Dense Port Concentrator Description . . . . . . . . . . . . . . . . . . . . . . . . . 53
MX960 Dense Port Concentrator LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
DPCs Supported on MX240, MX480, and MX960 Routers . . . . . . . . . . . . . . 56
MX960 DPC Port and Interface Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . 59
MX960 Flexible PIC Concentrator Description . . . . . . . . . . . . . . . . . . . . . . . . 62
MX960 Flexible PIC Concentrator (FPC) LEDs . . . . . . . . . . . . . . . . . . . . . . . . 65
FPCs Supported by MX240, MX480, and MX960 Routers . . . . . . . . . . . . . . . 65
MX960 PIC Port and Interface Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
PICs Supported by MX240, MX480, and MX960 Routers . . . . . . . . . . . . . . . 68
MX960 Application Services Modular Line Card Description . . . . . . . . . . . . . 69
MX960 AS MLC Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
MX960 SCB, Power Supply, and Cooling System Requirements for AS
MX960 Application Services Modular Storage Card Description . . . . . . . . . . 72
MX960 Application Services Modular Processing Card Description . . . . . . . . 73
MX960 Modular Interface Card Description . . . . . . . . . . . . . . . . . . . . . . . . . . 82
MX960 Modular Interface Card (MIC) LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . 82
MICs Supported by MX Series Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
MX960 MIC Port and Interface Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
MX960 Modular Port Concentrator Description . . . . . . . . . . . . . . . . . . . . . . . 89
MX960 Modular Port Concentrator LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
MPCs Supported by MX Series Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 97
Normal-Capacity AC Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Understanding Input Mode Switch (DIP Switch) Settings . . . . . . . . . . . . . . . 101
Copyright © 2017, Juniper Networks, Inc.
v
MX960 3D Universal Edge Router Hardware Guide vi
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 107
SCBE2 Interoperability with Existing Hardware . . . . . . . . . . . . . . . . . . . . . . . 116
Site Planning, Preparation, and Specifications
Clearance Requirements for Airflow and Hardware Maintenance for the MX960
MX960 Cabinet Size and Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . 130
Network Cable and Transceiver Overview for ACX Series and M Series
Supported Network Interface Standards by Transceiver for ACX Series, MX
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion . . . . 139
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable . . . . . . . . . . . 139
Attenuation and Dispersion in Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . 140
Calculating Power Budget and Power Margin for Fiber-Optic Cables . . . . . . . . . 140
Calculating Power Budget for Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . . 141
Calculating Power Margin for Fiber-Optic Cable . . . . . . . . . . . . . . . . . . . . . . . 141
Routing Engine Interface Cable and Wire Specifications for MX Series
MX960 Chassis Grounding Points Specifications . . . . . . . . . . . . . . . . . . . . . 145
MX960 Router Grounding Cable Lug Specifications . . . . . . . . . . . . . . . . . . . 147
MX960 Router Grounding Cable Specifications . . . . . . . . . . . . . . . . . . . . . . 148
RJ-45 Connector Pinouts for an MX Series Routing Engine ETHERNET Port . . . 148
Copyright © 2017, Juniper Networks, Inc.
Table of Contents
RJ-45 Connector Pinouts for MX Series Routing Engine AUX and CONSOLE
AC Power Requirements, Specifications, and Guidelines . . . . . . . . . . . . . . . 151
Electrical Specifications for the MX960 AC Power Supply . . . . . . . . . . . . . . . . . . 151
Calculating Power Requirements for MX960 Routers . . . . . . . . . . . . . . . . . . . . . . 161
AC Power Circuit Breaker Requirements for the MX960 Router . . . . . . . . . . . . . . 165
AC Power Cord Specifications for the MX960 Router . . . . . . . . . . . . . . . . . . . . . . 165
DC Power Requirements, Specifications, and Guidelines . . . . . . . . . . . . . . 169
Electrical Specifications for the MX960 DC Power Supply . . . . . . . . . . . . . . . . . 169
Calculating Power Requirements for MX960 Routers . . . . . . . . . . . . . . . . . . . . . . 179
DC Power Circuit Breaker Requirements for the MX960 Router . . . . . . . . . . . . . . 183
DC Power Source Cabling for the MX960 Router . . . . . . . . . . . . . . . . . . . . . . . . . 183
DC Power Cable Specifications for the MX960 Router . . . . . . . . . . . . . . . . . . . . . 185
Initial Installation and Configuration
Tools and Parts Required to Unpack the MX960 Router . . . . . . . . . . . . . . . . . . . 189
Installing the MX960 Mounting Hardware for a Four-Post Rack or Cabinet . . . . 195
Installing the MX960 Mounting Hardware for Front-Mounting in an Open-Frame
Installing the MX960 Mounting Hardware for Center-Mounting in an Open-Frame
Removing the Power Supplies Before Installing an MX960 Router with a
Removing the Fan Trays Before Installing an MX960 Router with a Lift . . . 207
Removing the SCBs Before Installing an MX960 Router with a Lift . . . . . . 209
Removing the DPCs Before Installing an MX960 Router with a Lift . . . . . . . 210
Removing the FPCs Before Installing the MX960 Router with a Lift . . . . . . . 212
Tools Required to Install the MX960 Router with a Mechanical Lift . . . . . . . . . . . 213
Installing the MX960 Router Using a Mechanical Lift . . . . . . . . . . . . . . . . . . . . . . 214
Reinstalling Components in the MX960 Chassis After Installing It with a Lift . . . 216
Reinstalling the Power Supplies After Installing the MX960 Router with a
Reinstalling the Fan Trays After Installing the MX960 Router with a Lift . . . 217
Reinstalling the SCBs After Installing the MX960 Router with a Lift . . . . . . 219
Copyright © 2017, Juniper Networks, Inc.
vii
MX960 3D Universal Edge Router Hardware Guide viii
Reinstalling the DPCs After Installing the MX960 Router with a Lift . . . . . . 220
Reinstalling the FPCs After Installing the MX960 Router with a Lift . . . . . . 222
Connecting the MX960 Router to Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Tools and Parts Required for MX960 Router Grounding and Power
Connecting Power to an AC-Powered MX960 Router with Normal-Capacity
Connecting Power to an AC-Powered MX960 Router with High-Capacity Power
Powering On an AC-Powered MX960 Router with Normal Capacity Power
Connecting Power to a DC-Powered MX960 Router with Normal-Capacity
Connecting Power to a DC-Powered MX960 Router with High-Capacity Power
Powering On a DC-Powered MX960 Router with Normal Capacity Power
Connecting an MX960 AC Power Supply Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Connecting an MX960 DC Power Supply Cable . . . . . . . . . . . . . . . . . . . . . . . . . . 244
Connecting the MX960 Router to the Network . . . . . . . . . . . . . . . . . . . . . . . 247
Tools and Parts Required for MX960 Router Connections . . . . . . . . . . . . . . . . . . 247
Connecting the MX960 Router to Management and Alarm Devices . . . . . . . . . . 247
Connecting the MX960 Router to a Network for Out-of-Band
Connecting the MX960 Router to a Management Console or Auxiliary
Connecting an MX960 Router to an External Alarm-Reporting Device . . . . 249
Connecting the MX960 Router to a Network for Out-of-Band Management . . 250
Connecting the MX960 Router to a Management Console or Auxiliary Device . . 251
Connecting an MX960 Router to an External Alarm-Reporting Device . . . . . . . . 252
Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router . . . . . . . . . . . . 253
Connecting the Alarm Relay Wires to the MX960 Craft Interface . . . . . . . . . . . . 255
Initially Configuring the MX960 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
Installing and Replacing Components
Overview of Installing and Replacing Components . . . . . . . . . . . . . . . . . . . 263
Tools and Parts Required for MX960 Router Connections . . . . . . . . . . . . . . . . . 264
Copyright © 2017, Juniper Networks, Inc.
Table of Contents
Installing a Cable on an MX960 DPC, MPC, MIC, or PIC . . . . . . . . . . . . . . . . . . . 289
Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC . . . 304
Disconnecting the Alarm Relay Wires from the MX960 Craft Interface . . . . 307
Removing the MX960 Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308
Connecting the Alarm Relay Wires to the MX960 Craft Interface . . . . . . . . 309
Replacing the Console or Auxiliary Cable on an MX960 Router . . . . . . . . . . . . . . 311
Replacing the Management Ethernet Cable on an MX Series Router . . . . . . . . . . 312
Removing an MX960 AS MSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
Replacing Cooling System Component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
Removing the Normal-Capacity MX960 Air Filter . . . . . . . . . . . . . . . . . . . . . 325
Copyright © 2017, Juniper Networks, Inc.
ix
MX960 3D Universal Edge Router Hardware Guide
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
Removing an MX960 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
Installing an MX960 Routing Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
Replacing an SSD Drive on an RE-S-X6-64G . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
Replacing Connections to MX960 Routing Engine Interface Ports . . . . . . . . . . . 343
Replacing the Management Ethernet Cable on an MX Series Router . . . . . 344
Replacing the Console or Auxiliary Cable on an MX960 Router . . . . . . . . . . 344
Upgrading to the RE-S-X6-64G Routing Engine in a Redundant Host
Installing the Routing Engine RE-S-X6-64G . . . . . . . . . . . . . . . . . . . . . . . . . 348
Verifying and Configuring the Upgraded Routing Engine as the Master . . . . 351
Verifying and Configuring the Upgraded Routing Engine as the Backup . . . . 351
Upgrading to the RE-S-X6-64G Routing Engine in a Nonredundant Host
Installing the Routing Engine RE-S-X6-64G . . . . . . . . . . . . . . . . . . . . . . . . . 353
Installing an MX960 Dual-Wide MIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
Replacing a Cable on an MX960 DPC, MPC, MIC, or PIC . . . . . . . . . . . . . . . . . . . 386
Removing a Cable on an MX960 DPC, MPC, MIC, or PIC . . . . . . . . . . . . . . . 386
Installing a Cable on an MX960 DPC, MPC, MIC, or PIC . . . . . . . . . . . . . . . . 387
Replacing Power System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
Removing a Normal Capacity MX960 AC Power Supply . . . . . . . . . . . . . . . . 391
Installing an MX960 AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394
Removing an MX960 DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395
Installing an MX960 DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
x Copyright © 2017, Juniper Networks, Inc.
Table of Contents
Replacing an MX960 AC Power Supply Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403
Disconnecting an MX960 AC Power Supply Cord . . . . . . . . . . . . . . . . . . . . . 403
Connecting an MX960 AC Power Supply Cord . . . . . . . . . . . . . . . . . . . . . . . 404
Replacing an MX960 DC Power Supply Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . 404
Disconnecting an MX960 DC Power Supply Cable . . . . . . . . . . . . . . . . . . . 405
Connecting an MX960 DC Power Supply Cable . . . . . . . . . . . . . . . . . . . . . . 406
Replacing Switch Fabric Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409
Upgrading an MX960 SCB to SCBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
Upgrading the SCB in the Backup Routing Engine . . . . . . . . . . . . . . . . . 416
Upgrading the SCB in the Master Routing Engine . . . . . . . . . . . . . . . . . . 418
Completing the SCB Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420
Upgrading an MX960 SCB or SCBE to SCBE2 . . . . . . . . . . . . . . . . . . . . . . . . 422
Preparing the MX960 Router for SCBE2 Upgrade . . . . . . . . . . . . . . . . . 423
Powering Off the MX960 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424
Removing an MX960 Routing Engine from an SCB or SCBE . . . . . . . . . 425
Replacing the SCB or SCBE with SCBE2 . . . . . . . . . . . . . . . . . . . . . . . . 425
Installing an MX960 Routing Engine into an SCBE2 . . . . . . . . . . . . . . . 425
Powering On the MX960 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
Completing the SCBE2 Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427
Upgrading the SCB in the Backup Routing Engine . . . . . . . . . . . . . . . . . . . . . 431
Upgrading the SCB in the Master Routing Engine . . . . . . . . . . . . . . . . . . . . . 433
Replacing an SFP or XFP Transceiver on an MX960 DPC, MPC, MIC, or PIC . . . . 437
Removing an SFP or XFP Transceiver from an MX960 DPC, MPC, MIC, or
Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or
Maintaining the Chassis and Components
Routine Maintenance Procedures for the MX960 Router . . . . . . . . . . . . . . . . . . 443
Tools and Parts Required to Maintain the MX960 Router . . . . . . . . . . . . . . . . . . 445
Maintaining the MX960 Host Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
Copyright © 2017, Juniper Networks, Inc.
xi
MX960 3D Universal Edge Router Hardware Guide xii
Maintaining Cables That Connect to MX960 DPCs, MPCs, MICs, or PICs . . . . . . 466
Verifying the Version of the MX960 Cable Manager . . . . . . . . . . . . . . . . . . . . . . 469
Converting to a Different Type of Power Supply . . . . . . . . . . . . . . . . . . . . . . 473
Converting from AC to DC Power Supplies on an MX960 Router . . . . . . . . . . . . 473
Converting from DC to AC Power Supplies on an MX960 Router . . . . . . . . . . . . 478
Troubleshooting Resources for MX960 Routers . . . . . . . . . . . . . . . . . . . . . . . . . . 487
Chassis and Interface Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 488
Juniper Networks Technical Assistance Center . . . . . . . . . . . . . . . . . . . . . . . 489
Troubleshooting the MX960 Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . 490
Troubleshooting the MX960 Power System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 498
Contacting Customer Support and Returning the Chassis or
Locating Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 507
Displaying MX960 Router Components and Serial Numbers . . . . . . . . . . . . . . . 507
MX960 Routing Engine Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . 509
MX960 Power Supply Serial Number Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512
Copyright © 2017, Juniper Networks, Inc.
Table of Contents
Packing and Returning Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 523
Contacting Customer Support to Obtain Return Material Authorization . . . . . . . 523
Guidelines for Packing Hardware Components for Shipment . . . . . . . . . . . . . . . 524
Returning a Hardware Component to Juniper Networks, Inc. . . . . . . . . . . . . . . . . 527
General Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . 529
Warning Statement for Norway and Sweden . . . . . . . . . . . . . . . . . . . . . . . . 534
Installation and Maintenance Safety Guidelines and Warnings . . . . . . . . . . . . . 534
Rack-Mounting and Cabinet-Mounting Warnings . . . . . . . . . . . . . . . . . . . . 536
Grounded Equipment Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 540
Laser and LED Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . . . . . 541
General Laser Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 541
Class 1 Laser Product Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 541
Class 1 LED Product Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 542
Radiation from Open Port Apertures Warning . . . . . . . . . . . . . . . . . . . . . . . . 543
Maintenance and Operational Safety Guidelines and Warnings . . . . . . . . . . . . . 544
Maintenance and Operational Safety Guidelines and Warnings . . . . . . . . . 544
Battery Handling Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544
Jewelry Removal Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 545
Operating Temperature Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 547
Product Disposal Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 548
General Electrical Safety Guidelines and Warnings . . . . . . . . . . . . . . . . . . . 550
Prevention of Electrostatic Discharge Damage . . . . . . . . . . . . . . . . . . . . . . . 551
AC Power Disconnection Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 553
DC Power Copper Conductors Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554
DC Power Disconnection Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 554
DC Power Grounding Requirements and Warning . . . . . . . . . . . . . . . . . . . . 556
DC Power Wiring Sequence Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 557
DC Power Wiring Terminations Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 559
Midplane Energy Hazard Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 560
Multiple Power Supplies Disconnection Warning . . . . . . . . . . . . . . . . . . . . . 560
Action to Take After an Electrical Accident . . . . . . . . . . . . . . . . . . . . . . . . . . 561
Copyright © 2017, Juniper Networks, Inc.
xiii
MX960 3D Universal Edge Router Hardware Guide
Agency Approvals and Compliance Statements . . . . . . . . . . . . . . . . . . . . . . . . . . 561
Agency Approvals and Compliance Statements for the MX2010 Router . . . 561
Agency Approvals for MX2010 Routers . . . . . . . . . . . . . . . . . . . . . . . . . . 561
Compliance Statements for NEBS for the MX2010 Router . . . . . . . . . . 562
Compliance Statements for EMC Requirements for the MX2010
Compliance Statements for Environmental Requirements for Juniper
Networks Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 564
Compliance Statements for EMC Requirements for Juniper Networks
European Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 564
Compliance Statements for Environmental Requirements for Juniper
Compliance Statements for NEBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 565
xiv Copyright © 2017, Juniper Networks, Inc.
List of Figures
Chassis Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 1: Front View of a Fully Configured MX960 Router Chassis . . . . . . . . . . . . . 10
Figure 2: Rear View of a Fully Configured AC-Powered MX960 Router
Figure 3: Rear View of a Fully Configured DC-Powered MX960 Router
Cooling System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 23
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 18: RE-S-X6-64G Routing Engine Front View . . . . . . . . . . . . . . . . . . . . . . . 34
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Figure 20: Typical DPCs Supported by the Router . . . . . . . . . . . . . . . . . . . . . . . . . 54
Figure 21: DPCs Installed Vertically in the MX960 Router . . . . . . . . . . . . . . . . . . . . 55
Figure 22: MX960 DPC Interface Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 23: FPC Installed in the MX960 Router Chassis . . . . . . . . . . . . . . . . . . . . . . 63
Figure 24: Typical FPCs Supported on the MX960 Router . . . . . . . . . . . . . . . . . . . 64
Figure 26: Application Services Modular Line Card (AS MLC) . . . . . . . . . . . . . . . . 70
Figure 27: AS MLC Installed in the MX960 Router Chassis . . . . . . . . . . . . . . . . . . . 71
Figure 28: Application Services Modular Storage Card . . . . . . . . . . . . . . . . . . . . . . 73
Figure 29: Application Services Modular Processing Card (AS MXC) . . . . . . . . . . 74
Copyright © 2017, Juniper Networks, Inc.
xv
MX960 3D Universal Edge Router Hardware Guide xvi
Figure 31: Typical MPC Supported on the MX960 Router . . . . . . . . . . . . . . . . . . . 90
Figure 32: MPC Installed Vertically in the MX960 Router . . . . . . . . . . . . . . . . . . . . 91
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 97
Figure 33: MX960 Normal-Capacity AC Power Supply . . . . . . . . . . . . . . . . . . . . . 99
Figure 34: MX960 with High-Capacity AC Power Supplies Installed . . . . . . . . . . 99
Figure 35: Setting the Input Mode Switch (DIP Switch) . . . . . . . . . . . . . . . . . . . . 101
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 107
Site Planning, Preparation, and Specifications
Figure 42: Chassis Dimensions and Clearance Requirements for the MX960
Router with the Normal-Capacity Power Supplies . . . . . . . . . . . . . . . . . . . . 129
Figure 43: Chassis Dimensions and Clearance Requirements for the MX960
Router with the Standard Cable Manager and High-Capacity DC Power
AC Power Requirements, Specifications, and Guidelines . . . . . . . . . . . . . . . 151
DC Power Requirements, Specifications, and Guidelines . . . . . . . . . . . . . . 169
Figure 49: Typical DC Source Cabling to the Router . . . . . . . . . . . . . . . . . . . . . . . 184
Initial Installation and Configuration
Figure 52: Installing the Mounting Hardware for a Four-Post Rack or Cabinet . . 197
Figure 53: Installing the Mounting Hardware for Front-Mounting in an Open-Frame
Figure 54: Installing the Mounting Hardware for Center-Mounting in an
Figure 55: Removing a Power Supply Before Installing the MX960 Router . . . . 206
Copyright © 2017, Juniper Networks, Inc.
List of Figures
Figure 56: Removing the Standard Cable Manager . . . . . . . . . . . . . . . . . . . . . . . 207
Figure 62: Installing the MX960 Router in the Rack . . . . . . . . . . . . . . . . . . . . . . . 215
Connecting the MX960 Router to Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Figure 70: Connecting AC Power to the MX960 Router . . . . . . . . . . . . . . . . . . . . 228
Figure 71: MX960 with High-Capacity AC Power Supplies Installed . . . . . . . . . . 229
Figure 72: MX960 AC Power Input Mode Switch . . . . . . . . . . . . . . . . . . . . . . . . . 230
Figure 73: Connecting DC Power to the MX960 Router . . . . . . . . . . . . . . . . . . . . 236
Figure 74: MX960 with High-Capacity DC Power Supplies Installed . . . . . . . . . . 237
Figure 75: MX960 DC High-Capacity Power Supply Front View . . . . . . . . . . . . . 240
Figure 76: Connecting Power Cables to the DC Power Supply . . . . . . . . . . . . . . . 245
Connecting the MX960 Router to the Network . . . . . . . . . . . . . . . . . . . . . . . 247
Figure 78: Routing Engine Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . 248
Figure 80: Routing Engine Console and Auxiliary Cable Connector . . . . . . . . . . . 249
Figure 83: Routing Engine Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . . 251
Figure 85: Routing Engine Console and Auxiliary Cable Connector . . . . . . . . . . . 252
Installing and Replacing Components
Copyright © 2017, Juniper Networks, Inc.
xvii
MX960 3D Universal Edge Router Hardware Guide xviii
Figure 106: Connecting DC Power to the MX960 Router . . . . . . . . . . . . . . . . . . . 297
Figure 115: Removing the Standard Cable Manager . . . . . . . . . . . . . . . . . . . . . . . . 311
Replacing Cooling System Component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
Figure 125: Removing the Normal-Capacity Air Filter Tray from the Chassis . . . . 326
Replacing Host Subsystem Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
Figure 135: Removing an SSD in the Routing Engine RE-S-X6-64G . . . . . . . . . . 340
Figure 136: Installing an SSD in the Routing Engine RE-S-X6-64G . . . . . . . . . . . 342
Figure 140: Removing a Routing Engine from an MX240 Router . . . . . . . . . . . . . 347
Figure 141: Removing a Routing Engine from an MX480 Router . . . . . . . . . . . . . . 347
Copyright © 2017, Juniper Networks, Inc.
List of Figures
Figure 142: Removing a Routing Engine from an MX960 Router . . . . . . . . . . . . . 348
Figure 143: Installing a Routing Engine in an MX240 Router . . . . . . . . . . . . . . . . 349
Figure 144: Installing a Routing Engine in an MX480 Router . . . . . . . . . . . . . . . . 350
Figure 145: Installing a Routing Engine in an MX960 Router . . . . . . . . . . . . . . . . 350
Replacing Power System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
Figure 162: Top of the Power Supply Showing Midplane Connector . . . . . . . . . . 393
Figure 164: Removing a DC Power Supply from the MX960 Router . . . . . . . . . . 398
Figure 165: Top of the Power Supply Showing Midplane Connector . . . . . . . . . . 398
Figure 167: Connecting DC Power to the MX960 Router . . . . . . . . . . . . . . . . . . . 403
Figure 168: Connecting Power Cables to the DC Power Supply . . . . . . . . . . . . . . 407
Replacing Switch Fabric Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409
Maintaining the Chassis and Components
Figure 175: Do Not Carry an FPC with Only One Hand . . . . . . . . . . . . . . . . . . . . . 459
Converting to a Different Type of Power Supply . . . . . . . . . . . . . . . . . . . . . . 473
Copyright © 2017, Juniper Networks, Inc.
xix
MX960 3D Universal Edge Router Hardware Guide
Figure 181: Removing an MX960 AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . 474
Figure 182: MX960 with High-Capacity DC Power Supplies Installed . . . . . . . . . 475
Figure 183: MX960 DC High-Capacity Power Supply Front View . . . . . . . . . . . . 478
Figure 184: Removing a DC Power Supply from the MX960 Router . . . . . . . . . . 480
Figure 185: MX960 with High-Capacity AC Power Supplies Installed . . . . . . . . . 481
Figure 186: MX960 AC Power Input Mode Switch . . . . . . . . . . . . . . . . . . . . . . . . 482
Figure 187: MX960 AC Power Input Mode Switch . . . . . . . . . . . . . . . . . . . . . . . . . 501
Contacting Customer Support and Returning the Chassis or
Locating Component Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 507
Figure 189: Routing Engine Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . 509
Figure 190: RE-S-X6-64G Routing Engine Serial Number Label . . . . . . . . . . . . . 510
Figure 193: MX960 Fan Tray Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . 512
Figure 194: AC Power Supply Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . 513
Figure 195: DC Power Supply Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . 513
Figure 205: Placing a Component into an Antistatic Bag . . . . . . . . . . . . . . . . . . . 552
xx Copyright © 2017, Juniper Networks, Inc.
List of Tables
Chassis Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Table 5: MX960 Router Hardware Components and CLI Terminology . . . . . . . . . . 13
Table 6: Alarm LEDs and Alarm Cutoff/Lamp Test Button . . . . . . . . . . . . . . . . . . . 16
Table 7: Host Subsystem LEDs on the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . 17
Table 9: DPC and MPC LEDs on the Craft Interface . . . . . . . . . . . . . . . . . . . . . . . . 18
Host Subsystem Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . 27
Table 15: RE-S-X6-64G Routing Engine LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 17: End-of-Life Routing Engine Specifications . . . . . . . . . . . . . . . . . . . . . . . 39
Table 23: MX5, MX10, MX40, and MX80 Routing Engine . . . . . . . . . . . . . . . . . . . . 43
Table 25: MX240 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Table 26: MX480 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Table 27: MX960 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Table 28: MX2008 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table 29: MX2010 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table 30: MX2020 Supported Routing Engines . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Copyright © 2017, Juniper Networks, Inc.
xxi
MX960 3D Universal Edge Router Hardware Guide xxii
Table 39: Routing Engines on TX Matrix Plus with 3D SIBs . . . . . . . . . . . . . . . . . . . 51
Line Card Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 40: DPCs Supported in MX240, MX480, and MX960 Routers . . . . . . . . . . 56
Table 41: FPCs Supported by MX Series Routers . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Table 42: PICs Supported by MX240, MX480, and MX960 Routers . . . . . . . . . . . 68
Table 51: MICs Supported by MX240, MX480, MX960, MX2008, MX2010, and
Table 52: MICs Supported by MX5, MX10, MX40, MX80, and MX104 Routers . . . 85
Table 53: MPCs Supported by MX240, MX480, MX960, MX2008, MX2010, and
Power System Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 97
Table 54: Minimum Number of Power Supplies Required for the MX960 . . . . . . 99
Table 55: Zoning for High-Capacity Power Supplies in an MX960 . . . . . . . . . . . . 101
Table 57: Minimum Required Number of DC Power Supplies . . . . . . . . . . . . . . . . 104
Switch Fabric Components and Descriptions . . . . . . . . . . . . . . . . . . . . . . . . 107
Site Planning, Preparation, and Specifications
Table 66: Clearance Requirements for High-Capacity Power Supplies . . . . . . . . 128
Table 69: Estimated Values for Factors Causing Link Loss . . . . . . . . . . . . . . . . . . 141
Copyright © 2017, Juniper Networks, Inc.
List of Tables
Table 70: Cable and Wire Specifications for Routing Engine Management and
Table 71: RJ-45 Connector Pinout for the Routing Engine ETHERNET Port . . . . . 148
Table 72: RJ-45 Connector Pinout for the AUX and CONSOLE Ports . . . . . . . . . . 149
AC Power Requirements, Specifications, and Guidelines . . . . . . . . . . . . . . . 151
Table 75: MX960 Common Component Power Requirements . . . . . . . . . . . . . . 153
Table 78: Sample Power Requirements for an MX960 Router . . . . . . . . . . . . . . . 163
DC Power Requirements, Specifications, and Guidelines . . . . . . . . . . . . . . 169
Table 84: Power System Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . 170
Table 85: MX960 Common Component Power Requirements . . . . . . . . . . . . . . . 171
Table 88: Sample Power Requirements for an MX960 Router . . . . . . . . . . . . . . . 181
Initial Installation and Configuration
Table 93: Parts List for a Fully Configured MX960 Router . . . . . . . . . . . . . . . . . . . 191
Table 95: Four-Post Rack or Cabinet Mounting Hole Locations . . . . . . . . . . . . . . 195
Table 96: Mounting Hardware Hole Locations for Front-Mounting in an
Table 97: Mounting Hardware Hole Locations for Center-Mounting in an
Connecting the MX960 Router to Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Table 98: MX960 High-Capacity AC Power Supply LEDs . . . . . . . . . . . . . . . . . . . 231
Table 99: MX960 High-Capacity DC Power Supply LEDs . . . . . . . . . . . . . . . . . . 239
Installing and Replacing Components
Overview of Installing and Replacing Components . . . . . . . . . . . . . . . . . . . 263
Copyright © 2017, Juniper Networks, Inc.
xxiii
MX960 3D Universal Edge Router Hardware Guide
Maintaining the Chassis and Components
Converting to a Different Type of Power Supply . . . . . . . . . . . . . . . . . . . . . . 473
Table 101: MX960 High-Capacity DC Power Supply LEDs . . . . . . . . . . . . . . . . . . 477
Table 102: MX960 High-Capacity AC Power Supply LEDs . . . . . . . . . . . . . . . . . . 483
xxiv Copyright © 2017, Juniper Networks, Inc.
About the Documentation
•
Documentation and Release Notes on page xxv
•
Supported Platforms on page xxv
•
Documentation Conventions on page xxv
•
Documentation Feedback on page xxvii
•
Requesting Technical Support on page xxviii
Documentation and Release Notes
To obtain the most current version of all Juniper Networks
® technical documentation, see the product documentation page on the Juniper Networks website at http://www.juniper.net/techpubs/ .
If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
Juniper Networks Books publishes books by Juniper Networks engineers and subject matter experts. These books go beyond the technical documentation to explore the nuances of network architecture, deployment, and administration. The current list can be viewed at http://www.juniper.net/books .
Supported Platforms
For the features described in this document, the following platforms are supported:
• MX960
Documentation Conventions
defines notice icons used in this guide.
Copyright © 2017, Juniper Networks, Inc.
xxv
MX960 3D Universal Edge Router Hardware Guide
Table 1: Notice Icons
Icon Meaning
Informational note
Caution
Warning
Laser warning
Tip
Best practice
Description
Indicates important features or instructions.
Indicates a situation that might result in loss of data or hardware damage.
Alerts you to the risk of personal injury or death.
Alerts you to the risk of personal injury from a laser.
Indicates helpful information.
Alerts you to a recommended use or implementation.
defines the text and syntax conventions used in this guide.
Table 2: Text and Syntax Conventions
Convention Description Examples
Bold text like this
Fixed-width text like this
Represents text that you type.
Represents output that appears on the terminal screen.
To enter configuration mode, type the configure command: user@host> configure user@host> show chassis alarms
No alarms currently active
Italic text like this
Italic text like this
•
•
•
Introduces or emphasizes important new terms.
Identifies guide names.
Identifies RFC and Internet draft titles.
•
•
•
A policy term is a named structure that defines match conditions and actions.
Junos OS CLI User Guide
RFC 1997, BGP Communities Attribute
Represents variables (options for which you substitute a value) in commands or configuration statements.
Configure the machine’s domain name:
[edit] root@# set system domain-name domain-name xxvi Copyright © 2017, Juniper Networks, Inc.
About the Documentation
Table 2: Text and Syntax Conventions
(continued)
Convention Description
Text like this
< > (angle brackets)
| (pipe symbol)
Examples
Represents names of configuration statements, commands, files, and directories; configuration hierarchy levels; or labels on routing platform components.
•
•
To configure a stub area, include the stub statement at the [edit protocols ospf area area-id] hierarchy level.
The console port is labeled CONSOLE .
Encloses optional keywords or variables.
stub <default-metric metric >;
Indicates a choice between the mutually exclusive keywords or variables on either side of the symbol. The set of choices is often enclosed in parentheses for clarity.
broadcast | multicast
( string1 | string2 | string3 )
# (pound sign)
[ ] (square brackets)
Indention and braces ( { } )
; (semicolon)
Indicates a comment specified on the same line as the configuration statement to which it applies.
rsvp { # Required for dynamic MPLS only
Encloses a variable for which you can substitute one or more values.
Identifies a level in the configuration hierarchy.
Identifies a leaf statement at a configuration hierarchy level.
community name members [ community-ids ]
[edit] routing-options { static { route default { nexthop address; retain;
}
}
}
GUI Conventions
Bold text like this
> (bold right angle bracket)
Represents graphical user interface (GUI) items you click or select.
•
•
In the Logical Interfaces box, select
All Interfaces .
To cancel the configuration, click
Cancel .
Separates levels in a hierarchy of menu selections.
In the configuration editor hierarchy, select Protocols>Ospf .
Documentation Feedback
We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can provide feedback by using either of the following methods:
• Online feedback rating system—On any page of the Juniper Networks TechLibrary site at http://www.juniper.net/techpubs/index.html
, simply click the stars to rate the content, and use the pop-up form to provide us with information about your experience.
Alternately, you can use the online feedback form at http://www.juniper.net/techpubs/feedback/ .
Copyright © 2017, Juniper Networks, Inc.
xxvii
MX960 3D Universal Edge Router Hardware Guide
• E-mail—Send your comments to [email protected]
. Include the document or topic name, URL or page number, and software version (if applicable).
Requesting Technical Support
Technical product support is available through the Juniper Networks Technical Assistance
Center (JTAC). If you are a customer with an active J-Care or Partner Support Service support contract, or are covered under warranty, and need post-sales technical support, you can access our tools and resources online or open a case with JTAC.
• JTAC policies—For a complete understanding of our JTAC procedures and policies, review the JTAC User Guide located at http://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf
.
• Product warranties—For product warranty information, visit http://www.juniper.net/support/warranty/ .
• JTAC hours of operation—The JTAC centers have resources available 24 hours a day,
7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features:
• Find CSC offerings: http://www.juniper.net/customers/support/
• Search for known bugs: http://www2.juniper.net/kb/
• Find product documentation: http://www.juniper.net/techpubs/
• Find solutions and answer questions using our Knowledge Base: http://kb.juniper.net/
• Download the latest versions of software and review release notes: http://www.juniper.net/customers/csc/software/
• Search technical bulletins for relevant hardware and software notifications: http://kb.juniper.net/InfoCenter/
• Join and participate in the Juniper Networks Community Forum: http://www.juniper.net/company/communities/
• Open a case online in the CSC Case Management tool: http://www.juniper.net/cm/
To verify service entitlement by product serial number, use our Serial Number Entitlement
(SNE) Tool: https://tools.juniper.net/SerialNumberEntitlementSearch/
Opening a Case with JTAC
You can open a case with JTAC on the Web or by telephone.
• Use the Case Management tool in the CSC at http://www.juniper.net/cm/ .
• Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
xxviii Copyright © 2017, Juniper Networks, Inc.
About the Documentation
For international or direct-dial options in countries without toll-free numbers, see http://www.juniper.net/support/requesting-support.html
.
Copyright © 2017, Juniper Networks, Inc.
xxix
MX960 3D Universal Edge Router Hardware Guide xxx Copyright © 2017, Juniper Networks, Inc.
PART 1
Overview
•
•
•
Chassis Components and Descriptions on page 9
•
Cooling System Components and Descriptions on page 23
•
Host Subsystem Components and Descriptions on page 27
•
Line Card Components and Descriptions on page 53
•
Power System Components and Descriptions on page 97
•
Switch Fabric Components and Descriptions on page 107
Copyright © 2017, Juniper Networks, Inc.
1
MX960 3D Universal Edge Router Hardware Guide
2 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 1
System Overview
•
MX960 Router Overview on page 3
MX960 Router Overview
The MX960 3D Universal Edge Router is an Ethernet-optimized edge router that provides both switching and carrier-class Ethernet routing. The MX960 router enables a wide range of business and residential applications and services, including high-speed transport and VPN services, next-generation broadband multiplay services, high-speed Internet and data center internetworking.
The MX960 chassis provides redundancy and resiliency. The hardware system is fully redundant, including power supplies, fan trays, Routing Engines, and Switch Control
Boards.
The MX960 router is 16 rack units (U) tall. Three routers can be stacked in a single floor-to-ceiling rack, for increased port density per unit of floor space. The router provides
14 slots that can be populated with 11 or 12 Dense Port Concentrators (DPCs) or Modular
Port Concentrators (MPCs), six Flexible PIC Concentrators (FPCs), and two Switch
Control Boards (SCBs) in nonredundant fabric configurations.
Fully populated, the MX960 router provides an aggregate switch fabric capacity of up to 10.56 Tbps, with line-rate throughput on 264 10-Gigabit Ethernet ports, 22 100-Gigabit
Ethernet and 44 10-Gigabit Ethernet ports and 66 40-Gigabit Ethernet ports.
lists the MX960 router capacity.
Table 3: MX960 Router Capacity
Description Capacity
System capacity
Switch fabric capacity per slot
MPCs and DPCs per chassis
Chassis per rack
10.56 Tbps half duplex
480 Gbps
11 or 12 (depending on protection scheme)
3
Copyright © 2017, Juniper Networks, Inc.
3
MX960 3D Universal Edge Router Hardware Guide
Several types of DPCs are available. Each DPC includes either two or four Packet
Forwarding Engines. Each Packet Forwarding Engine enables a throughput of 10 Gbps.
Up to two PICs can be installed in each FPC. Fully populated, the MX960 supports up to
12 PICs.
Up to two Modular Interface Cards (MICs) can be installed in each MPC. Fully populated, the MX960 supports up to 24 MICs.
MPCs support fixed interfaces or up to two Modular Interface Cards (MICs) that can be installed in each MPC. Fully populated, the MX960 supports up to 22 MICs.
For a list of the supported DPCs, FPCs, MPCs, MICs, and PICs, see the MX Series Interface
Module Reference .
Three SCBs are available for the MX960 routers—the SCB, the SCBE, and the SCBE2.
lists the MX960 SCBs.
Table 4: SCB Comparison
Model Number Description Switch Fabric Capacity
SCBE2- MX-BB
SCBE-MX-BB
SCB-MX-BB
Enhanced MX Switch Control Board (SCBE2)
Enhanced Switch Control Board (SCBE)
Switch Control Board (SCB)
10.56 Tbps (half-duplex)
5.12Tbps
2.64 Tbps
The connections between interface cards and SCBs are organized in three groups:
• Switch fabric—Connects the interface cards and provides for packet transport between
DPCs, FPCs, and MPCs. Two SCBs provide one nonredundant fabric. Three SCBS are required for a redundant fabric configuration.
• Control Plane—Gigabit Ethernet links between the combined SCBs/Routing Engines and each DPC, FPC, or MPC. All board-to-board information is passed over Ethernet except for low-level status and commands.
• Management signals—Provide low-level status diagnostic support.
Related
Documentation
•
MX960 Component Redundancy on page 12
•
MX960 Router Physical Specifications on page 121
•
MX960 Chassis Description on page 9
•
MX960 Host Subsystem Description on page 27
•
MX960 Craft Interface Overview on page 15
•
MX960 Power System Overview on page 97
•
MX960 Cooling System Description on page 23
4 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 2
MX960 Release Notes
•
Outstanding Issues with the MX960 Router on page 5
•
Errata with the MX960 Router Documentation on page 7
Outstanding Issues with the MX960 Router
This topic lists outstanding hardware issues with the MX960 3D Universal Edge router.
For information about software issues, see the Junos OS Release Notes.
• Each MX960 high capacity AC power supply has an input mode switch, covered by a small metal plate. The input mode switch tells the system the number of feeds it should expect When the input mode switch is set to '0' (zero): expect one feed, an alarm will be generated if two are providing power. When the input mode swtich is set to '1' (one): expect two feeds, an alarm will be generated if less than two feeds are active. The default setting is 1.
In Junos OS Releases 10.1R2 and 10.2R1. there are scenarios in which both the supply and the system will generate a warning or alarm, and there is at least one scenario where the supply is OK and the system will still give a warning message. [PR530872]
Copyright © 2017, Juniper Networks, Inc.
5
MX960 3D Universal Edge Router Hardware Guide
The power supply has a PEM FAIL and OK LED; the failure LED will light up in this scenario:
• Supply is expecting two feeds (input mode switch = 1) but receiving only one active feed
The system will generate an alarm in the following scenarios:
• Supply is expecting two feeds (input mode switch = 1) but receiving only one active feed.
•
.
Supply is expecting one feed (input mode switch = 0) but receiving two active feeds
•
NOTE:
All supplies should have the same amount of feeds activated.
• The correct usage of the feed selector is required in order to get to the desired capacity of the supplies.
• Juniper Networks strongly recommends that you install Junos OS Release 8.2R2 or later before deploying the MX960 router into service.
• Junos OS Release 8.2R1 does not allow you to complete an install from the USB dongle. Use Junos OS Release 8.2R2 instead. [PR/98563]
• In Junos OS Release 8.2R1, a condition can exist where both fan trays are shut down by the system, but the system continues to operate. This can potentially result in serious overheating and damage to the DPCs. Use Junos OS Release 8.2R2 instead.
[PR/94692] [PR/289154]
• The XFP cages and optics on the MX960 router are industry standard parts which have limited tactile feedback for insertion of optics and fiber. You need to insert the optics and fiber firmly until the latch is securely in place. [PR/98055]
• Although the MX960 router can support any combination of 11 DPCs and the redundant third SCB, the power supply cannot support all 12 DPCs if an Enhanced Queuing DPC is inserted into any slot of a fully loaded chassis. The Enhanced Queuing DPCs exhibit the following behavior:
• When you insert an Enhanced Queuing DPC into slot 6 of a powered-on MX960 router, the DPC will not power on.
• When you insert a DPC into slot 6 of an MX960 router containing an Enhanced
Queuing DPC in any slot, the DPC will not power on.
• When you insert an Enhanced Queuing DPC into any slot of an MX960 router containing a DPC already powered on in slot 6 , the Enhanced Queuing DPC will not power on.
6 Copyright © 2017, Juniper Networks, Inc.
Chapter 2: MX960 Release Notes
These scenarios raise an FPC misconfiguration red alarm due to the DPC's high power consumption. To clear the alarm, perform one of the following actions:
• To temporarily take the DPC offline, use the request chassis fpc slot slot-number offline command from the CLI.
NOTE: The router does not preserve the state after a reboot.
• To take the DPC offline and preserve the state after a reboot, use the set chassis fpc slot-number power off command from configuration mode.
• Remove the powered-off DPC from the MX960 router.
Juniper Networks also recommends the following best practices:
• Use all other slots before using slot 6 .
• Remove any unused DPCs plugged into the MX960 chassis.
Related
Documentation
•
Errata with the MX960 Router Documentation on page 7
Errata with the MX960 Router Documentation
This topic lists outstanding documentation issues:
• There are no outstanding documentation issues at this time.
Related
Documentation
•
Outstanding Issues with the MX960 Router on page 5
Copyright © 2017, Juniper Networks, Inc.
7
MX960 3D Universal Edge Router Hardware Guide
8 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 3
Chassis Components and Descriptions
•
MX960 Chassis Description on page 9
•
MX960 Component Redundancy on page 12
•
MX960 Router Hardware and CLI Terminology Mapping on page 12
•
MX960 Rack-Mounting Hardware on page 14
•
MX960 Craft Interface Overview on page 15
•
MX960 Alarm Relay Contacts on the Craft Interface on page 15
•
MX960 Alarm LEDs and Alarm Cutoff/Lamp Test Button on page 16
•
MX960 Component LEDs on the Craft Interface on page 17
•
MX960 Cable Manager Description on page 19
MX960 Chassis Description
The router chassis is a rigid sheet metal structure that houses all the other router components (see
,
, and
). The chassis installs in many types of racks, including 800-mm deep (or larger) enclosed cabinets, standard 19-in. equipment racks, or telco open-frame racks. Two types of chassis are available for the MX960 router:
• The standard chassis measures 27.75 in. (70.49 cm) high, 17.37 in. (44.11 cm) wide
(excluding the mounting flanges and brackets), and 23.0 in. (58.42 cm) deep (from the front-mounting flanges to the rear of the chassis). The standard cable manager extends the depth to 28.0 in. (71.1 cm). Up to three routers can be installed in a 48-U rack if the rack can handle their combined weight, which can be greater than 1,050 lb
(476.3 kg).
NOTE: The chassis depth with the high-capacity AC power supply is 30.6" and the depth with high-capacity DC power supply is 32.8".
• The chassis with the extended cable manager installed measures 36.5 in. (92.7 cm) high, 17.37 in. (44.11 cm) wide, and approximately 29.00 in. (73.7 cm) deep (from the front-mounting flanges to the rear of the extended cable manager). Up to two routers with the extended cable manager can be installed in a 48-U rack if the rack can handle their combined weight, which can be greater than 748 lb (339.28 kg).
Copyright © 2017, Juniper Networks, Inc.
9
MX960 3D Universal Edge Router Hardware Guide
Mounting hardware includes front-mounting flanges on the front of the chassis, and two center-mounting brackets attached to the center of the chassis.
Figure 1: Front View of a Fully Configured MX960 Router Chassis
10 Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Figure 2: Rear View of a Fully Configured AC-Powered MX960 Router
Chassis
Air exhaust
Input mode switch
AC Power supplies
Power supply ejectors
Grounding points ESD point
Figure 3: Rear View of a Fully Configured DC-Powered MX960 Router
Chassis
Air exhaust
Input mode switch
DC Power supplies
Power supply ejectors
Grounding points ESD point
Related
Documentation
•
MX960 Router Physical Specifications on page 121
•
Installing the MX960 Mounting Hardware for a Four-Post Rack or Cabinet on page 195
Copyright © 2017, Juniper Networks, Inc.
11
MX960 3D Universal Edge Router Hardware Guide
•
MX960 Router Grounding Specifications on page 145
MX960 Component Redundancy
A fully configured router is designed so that no single point of failure can cause the entire system to fail. Only a fully configured router provides complete redundancy. All other configurations provide partial redundancy. The following major hardware components are redundant:
• Host subsystem—The host subsystem consists of a Routing Engine and an SCB. The router can have one or two host subsystems. If two host subsystems are installed, one functions as the master and the other functions as the backup. If the master host subsystem (or either of its components) fails, the backup can take over as the master.
To operate, each host subsystem requires a Routing Engine installed directly into in an SCB.
• Power supplies—In the AC configuration with normal capacity AC power supplies, a minimum of three power supplies is required to supply power to a fully configured router. All AC power supplies share the load evenly. The addition of a fourth power supply provides full power redundancy. If one power supply fails in a redundant configuration, the three remaining power supplies provide full power. In the DC configuration and the AC configuration with high capacity power supplies, two power supplies are required to supply power to a fully configured router. One power supply supports approximately half of the components in the router, and the other power supply supports the remaining components. The addition of two power supplies provides full power redundancy. If one or two power supplies fail, the remaining power supplies can provide full power to the router.
• Cooling system—The cooling system has redundant components, which are controlled by the host subsystem. If one of the fans fails, the host subsystem increases the speed of the remaining fans to provide sufficient cooling for the router indefinitely.
Related
Documentation
•
MX960 Router Overview on page 3
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Guidelines for Packing Hardware Components for Shipment on page 524
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
MX960 Router Hardware and CLI Terminology Mapping
The MX960 router supports the components in
.
12 Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Table 5: MX960 Router Hardware Components and CLI Terminology
Component Hardware Model Number CLI Name Description
Chassis MX960BASE-AC
MX960BASE-DC
MX960
“MX960 Chassis Description” on page 9
Craft Interface Panel CRAFT-MX960-S Front Panel Display
“MX960 Craft Interface Overview” on page 15
Cooling System
Fan tray
Filter tray
FFANTRAY-MX960
FFILTER-MX960
FFILTER-MX960-HC
FLTR-KIT-MX960
Fan Tray
N/A
N/A
N/A
Filter kit
Host Subsystem
Routing Engine
SCB
See
“Supported Routing Engines by Router” on page 40
.
MX960-SCB-S MX SCB
“MX960 SCB Description” on page 107
Interface Modules
DPC
DPC or SCB blank panel DPC-SCB-BLANK
FPC MX-FPC2
MIC
N/A
MX FPC Type 2
MX FPC Type 3
“MX960 Flexible PIC Concentrator
MX-FPC3
See
“MICs Supported by MX Series Routers” on page 82
in the
MX Series Interface Module Reference .
MIC-BLANK N/A MIC blank panel
MPC See
“MPCs Supported by MX Series Routers” on page 92
in the
MX Series Interface Module Reference .
Concentrator Description” on page 89
PIC
See
“DPCs Supported on MX240, MX480, and MX960 Routers” on page 56
in the MX Series Interface Module Reference .
“MX960 Dense Port Concentrator
See
“PICs Supported by MX240, MX480, and MX960 Routers” on page 68
in the MX Series Interface Module Reference .
“MX960 PIC Description” on page 66
Copyright © 2017, Juniper Networks, Inc.
13
MX960 3D Universal Edge Router Hardware Guide
Table 5: MX960 Router Hardware Components and CLI Terminology
(continued)
Component Hardware Model Number CLI Name Description
Enhanced MX SCB
Transceiver
SCBE-MX960-S
See MX Series Interface
Module Reference .
Xcvr
Transceiver into an MX960 DPC,
Power System
Power distribution module (PDM)
AC power supply
DC power supply
Power supply blank panel
Power Distribution Module
PWR-MX960-AC
PWR-MX960-4100-AC
PWR-MX960-DC
PWR-MX960-4100-DC
PWR-BLANK-MX960
“MX960 Power System Overview” on page 97
Power Distribution Module
“MX960 Power System Overview” on page 97
AC Power Entry Module
AC 4.1kW Power Entry
Module
DC Power Entry Module
“MX960 DC Power Supply” on page 104
DC 4.1kW Power Entry
Module
N/A
“MX960 Power System Overview” on page 97
Related
Documentation
•
MX960 Router Overview on page 3
•
MX960 DPC Port and Interface Numbering on page 59
•
MX960 MIC Port and Interface Numbering on page 86
•
MX960 PIC Port and Interface Numbering on page 66
• MX Series Router Interface Names
MX960 Rack-Mounting Hardware
The rack-mounting hardware for the MX960 router includes:
• The large mounting shelf for mounting in four-post racks, cabinets, and open-frame racks
• The small mounting shelf for front-mounting in a four-post rack or cabinet
14 Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
• Front-mounting flanges on the front of the chassis for front-mounting in a four-post rack or cabinet
• Two center-mounting brackets attached to the center of the chassis for center-mounting in an open-frame rack. For an open-frame rack, center-mounting is preferable because of the more even distribution of weight.
Related
Documentation
•
MX960 Chassis Description on page 9
•
MX960 Midplane Description on page 28
•
Installing the MX960 Mounting Hardware for Center-Mounting in an Open-Frame Rack on page 199
•
Installing the MX960 Mounting Hardware for Front-Mounting in an Open-Frame Rack on page 197
•
Installing the MX960 Mounting Hardware for a Four-Post Rack or Cabinet on page 195
MX960 Craft Interface Overview
The craft interface allows you to view status and troubleshooting information at a glance and to perform many system control functions. It is hot-insertable and hot-removable.
The craft interface is located on the front of the router above the card cage and contains
LEDs for the router components, the alarm relay contacts, and alarm cutoff button. See
.
Figure 4: Front Panel of the Craft Interface
NOTE: At least one SCB must be installed in the router for the craft interface to obtain power.
Related
Documentation
•
Replacing the MX960 Craft Interface on page 307
•
MX960 Craft Interface Serial Number Label on page 511
MX960 Alarm Relay Contacts on the Craft Interface
The craft interface has two alarm relay contacts for connecting the router to external alarm devices (see
). Whenever a system condition triggers either
Copyright © 2017, Juniper Networks, Inc.
15
MX960 3D Universal Edge Router Hardware Guide the red or yellow alarm on the craft interface, the alarm relay contacts are also activated.
The alarm relay contacts are located on the upper right of the craft interface.
Figure 5: Alarm Relay Contacts
Related
Documentation
•
Disconnecting the Alarm Relay Wires from the MX960 Craft Interface on page 307
•
Connecting the Alarm Relay Wires to the MX960 Craft Interface on page 255
MX960 Alarm LEDs and Alarm Cutoff/Lamp Test Button
Two large alarm LEDs are located at the upper right of the craft interface. The circular red LED lights to indicate a critical condition that can result in a system shutdown. The triangular yellow LED lights to indicate a less severe condition that requires monitoring or maintenance. Both LEDs can be lit simultaneously.
A condition that causes an LED to light also activates the corresponding alarm relay contact on the craft interface.
To deactivate red and yellow alarms, press the button labeled ACO/LT (for “alarm cutoff/lamp test”), which is located to the right of the alarm LEDs. Deactivating an alarm turns off both LEDs and deactivates the device attached to the corresponding alarm relay contact on the craft interface.
describes the alarm LEDs and alarm cutoff button in more detail.
Table 6: Alarm LEDs and Alarm Cutoff/Lamp Test Button
Shape Color State Description
Red
Yellow
–
On steadily Critical alarm LED—Indicates a critical condition that can cause the router to stop functioning. Possible causes include component removal, failure, or overheating.
On steadily Warning alarm LED—Indicates a serious but nonfatal error condition, such as a maintenance alert or a significant increase in component temperature.
– Alarm cutoff/lamp test button—Deactivates red and yellow alarms. Causes all LEDs on the craft interface to light (for testing) when pressed and held.
16 Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Related
Documentation
•
MX960 Craft Interface Overview on page 15
•
MX960 Alarm Relay Contacts on the Craft Interface on page 15
•
MX960 Router Overview on page 3
MX960 Component LEDs on the Craft Interface
•
MX960 Host Subsystem LEDs on the Craft Interface on page 17
•
MX960 Power Supply LEDs on the Craft Interface on page 17
•
MX960 DPC and MPC LEDs on the Craft Interface on page 18
•
MX960 FPC LEDs on the Craft Interface on page 18
•
MX960 SCB LEDs on the Craft Interface on page 18
•
MX960 Fan LEDs on the Craft Interface on page 19
MX960 Host Subsystem LEDs on the Craft Interface
Each host subsystem has three LEDs, located in the middle of the craft interface, that indicate its status. The LEDs labeled RE0 show the status of the Routing Engine in slot
0 and the SCB in slot 0 . The LEDs labeled RE1 show the status of the Routing Engine and
SCB in slot 1 .
describes the functions of the host subsystem LEDs.
Table 7: Host Subsystem LEDs on the Craft Interface
Label Color State Description
MASTER
ONLINE
OFFLINE
Green
Green
Red
–
On steadily Host is functioning as the master.
On steadily Host is online and is functioning normally.
On steadily Host is installed but the Routing Engine is offline.
Off Host is not installed.
MX960 Power Supply LEDs on the Craft Interface
Each power supply has two LEDs on the craft interface that indicate its status. The LEDs, labeled 0 through 3 , are located on the upper left of the craft interface next to the PEM label.
describes the functions of the power supply LEDs on the craft interface.
Table 8: Power Supply LEDs on the Craft Interface
Label Color State Description
PEM Green On steadily Power supply is functioning normally.
Red On steadily Power supply has failed or power input has failed.
Copyright © 2017, Juniper Networks, Inc.
17
MX960 3D Universal Edge Router Hardware Guide
MX960 DPC and MPC LEDs on the Craft Interface
Each DPC or MPC has LEDs on the craft interface that indicate its status. The LEDs, labeled 0 through 5 , 2/6 , and 7 through 11 , are located along the bottom of the craft interface. Slot 2/6 is for an additional DPC, FPC, MPC, or SCB.
describes the functions of the LEDs.
Table 9: DPC and MPC LEDs on the Craft Interface
Label Color State Description
OK Green
FAIL
–
Red
On steadily Card is functioning normally.
Blinking
Off
Card is transitioning online or offline.
The slot is not online.
On steadily Card has failed.
MX960 FPC LEDs on the Craft Interface
An FPC takes up two DPC slots when installed in an MX Series router. The LEDs, labeled
0 through 5 , 2/6 , and 7 through 11 , are located along the bottom of the craft interface.
Slot 2/6 is for an additional DPC, FPC, MPC, or SCB. The LED corresponds to the lowest
DPC slot number in which the FPC is installed.
describes the functions of the FPC LEDs.
Table 10: FPC LEDs on the Craft Interface
Label Color State Description
OK Green
–
On steadily FPC is functioning normally.
Blinking
Off
FPC is transitioning online or offline.
The slot is not online.
FAIL Red On steadily FPC has failed.
MX960 SCB LEDs on the Craft Interface
Each SCB has two LEDs on the craft interface that indicates its status. The SCB LEDs, labeled 0 , 1 , and 2/6 , are located along the bottom of the craft interface.
describes the functions of the SCB LEDs.
18 Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Table 11: SCB LEDs on the Craft Interface
Label Color State Description
OK Green
FAIL
–
Red
On steadily SCB: Fabric and control board functioning normally.
Blinking
Off
SCB is transitioning online or offline.
The slot is not online.
On steadily SCB has failed.
MX960 Fan LEDs on the Craft Interface
The fan LEDs are located on the top left of the craft interface.
describes the functions of the fan LEDs.
Table 12: Fan LEDs on the Craft Interface
Label Color State Description
FAN Green On steadily Fan is functioning normally.
Red On steadily Fan has failed.
Related
Documentation
•
MX960 Craft Interface Overview on page 15
•
MX960 Alarm Relay Contacts on the Craft Interface on page 15
MX960 Cable Manager Description
The standard cable manager (see
Figure 6 on page 20 ) is a tray located below the
line-card cage, which has a row of fourteen dividers for securing the cables for each Dense
Port Concentrator (DPC), Modular Port Concentrator (MPC), Modular Interface Card
(MIC), or PIC.
You can use cable strips or other ties to gently secure the cables in the standard cable manager. To secure the cables in place, loop the tie through the cable anchor and secure the tie. You can pull the standard cable manager up and outward to lock it into the maintenance position. This allows you to access the lower fan tray and the air filter.
Copyright © 2017, Juniper Networks, Inc.
19
MX960 3D Universal Edge Router Hardware Guide
Figure 6: Standard Cable Manager
Maintenance linkage
Release handles
The extended cable manager allows you to route cables away from the front of the DPCs,
MPCs, MICs, and PICs, and provides additional access (see
and
).
Figure 7: Extended Cable Manager
20 Copyright © 2017, Juniper Networks, Inc.
Chapter 3: Chassis Components and Descriptions
Figure 8: Extended Cable Manager Cover
Related
Documentation
•
Replacing the MX960 Cable Manager on page 310
•
Verifying the Version of the MX960 Cable Manager on page 469
Copyright © 2017, Juniper Networks, Inc.
21
MX960 3D Universal Edge Router Hardware Guide
22 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 4
Cooling System Components and
Descriptions
•
MX960 Cooling System Description on page 23
•
MX960 Cooling System Description
The cooling system consists of the following components:
• Upper front fan tray
• Lower front fan tray
• Front air filter
The cooling system components work together to keep all router components within the acceptable temperature range (see
Figure 9 on page 24 , Figure 10 on page 24
,
, and
). The router has two fan trays located in the front of the router that install horizontally above and below the card cage. Each normal-capacity fan tray contains six fans. High-capacity fan trays that contain twelve fans can be installed in the upper and lower fan tray slots. The fan trays are hot-insertable and hot-removable.
The MX960 requires high-capacity fan trays to satisfy cooling requirements for high-density DPCs and MPCs. When replacing normal-capacity fan trays with high-capacity fan trays, you must replace them in both the upper and lower fan trays.
Additionally, you must replace the front air filter.
NOTE: If you install high-capacity fan trays, you must also install high-capacity power supplies. Combinations of normal-capacity and high-capacity power supplies and fan trays are not supported.
There is a single air intake in the front of the router. Air is pushed up through the card cage and through the upper fan tray where it is exhausted out the upper rear of the system through the larger air exhaust shown in
.
Copyright © 2017, Juniper Networks, Inc.
23
MX960 3D Universal Edge Router Hardware Guide
At the bottom rear of the chassis, there is an air intake for power supply cooling. Air flows over the power supplies and is exhausted out the rear of the chassis through the smaller air exhaust below the main exhaust.
Figure 9: Airflow Through the Chassis
24
The host subsystem monitors the temperature of the router components. When the router is operating normally, the fans function at lower than full speed. If a fan fails or the ambient temperature rises above a threshold, the speed of the remaining fans is automatically adjusted to keep the temperature within the acceptable range. If the ambient maximum temperature specification is exceeded and the system cannot be adequately cooled, the Routing Engine shuts down the system by disabling output power from each PEM.
Figure 10: Upper Fan Tray
Figure 11: Air Filter
Figure 12: Air Filter Tray
Copyright © 2017, Juniper Networks, Inc.
Figure 13: High-Capacity Fan Tray
Chapter 4: Cooling System Components and Descriptions
Figure 14: High-Capacity Filter Tray with Air Filter
Air filter
Air filter tray
Related
Documentation
•
Troubleshooting the MX960 Cooling System on page 490
•
Maintaining the MX960 Air Filter on page 446
•
Maintaining the MX960 Fan Trays on page 446
MX960 Fan LED
Each fan has an LED that displays its status. The fan LEDs are located on the top left of the craft interface. For more information, see
“MX960 Fan LEDs on the Craft Interface” on page 19
.
Related
Documentation
•
MX960 Cooling System Description on page 23
•
Maintaining the MX960 Fan Trays on page 446
•
Troubleshooting the MX960 Cooling System on page 490
Copyright © 2017, Juniper Networks, Inc.
25
MX960 3D Universal Edge Router Hardware Guide
26 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 5
Host Subsystem Components and
Descriptions
•
MX960 Host Subsystem Description on page 27
•
MX960 Host Subsystem LEDs on page 28
•
MX960 Midplane Description on page 28
•
MX960 Routing Engine Description on page 29
•
MX960 RE-S-1300 and RE-S-2000 Routing Engine LEDs on page 31
•
RE-S-1800 Routing Engine Description for MX Series on page 31
•
RE-S-1800 Routing Engine LEDs on page 33
•
RE-S-X6-64G Routing Engine Description on page 34
•
RE-S-X6-64G Routing Engine LEDs on page 36
•
Routing Engine Specifications on page 37
•
Supported Routing Engines by Router on page 40
MX960 Host Subsystem Description
The host subsystem provides the routing and system management functions of the router. You can install one or two host subsystems on the router. Each host subsystem functions as a unit; the Routing Engine must be installed directly into the Switch Control
Board.
NOTE: We recommend that you install two host subsystems for redundant protection. If you install only one host subsystem, we recommend that you install it in slot 0 .
Each host subsystem has three LEDs that display its status. The host subsystem LEDs are located in the middle of the craft interface.
Related
Documentation
•
MX960 Host Subsystem LEDs on page 28
•
Maintaining the MX960 Host Subsystem on page 448
• Taking an MX960 Host Subsystem Offline
Copyright © 2017, Juniper Networks, Inc.
27
MX960 3D Universal Edge Router Hardware Guide
• Effect of Taking the MX960 Host Subsystem Offline
•
Replacing an MX960 Routing Engine on page 333
•
Replacing an MX960 SCB on page 409
MX960 Host Subsystem LEDs
Each host subsystem has three LEDs that display its status. The host subsystem LEDs are located in the middle of the craft interface. For more information, see
Subsystem LEDs on the Craft Interface” on page 17 .
Related
Documentation
•
MX960 Host Subsystem Description on page 27
•
Maintaining the MX960 Host Subsystem on page 448
• Taking an MX960 Host Subsystem Offline
MX960 Midplane Description
The midplane is located toward the rear of the chassis and forms the rear of the card cage (see
). The line cards and SCBs install into the midplane from the front of the chassis, and the power supplies install into the midplane from the rear of the chassis. The cooling system components also connect to the midplane.
The midplane performs the following major functions:
• Data path—Data packets are transferred across the midplane between the line cards through the fabric ASICs on the SCBs.
• Power distribution—The router power supplies connect to the midplane, which distributes power to all the router components.
• Signal path—The midplane provides the signal path to the line cards, SCBs, Routing
Engines, and other system components for monitoring and control of the system.
28 Copyright © 2017, Juniper Networks, Inc.
Figure 15: Midplane
Chapter 5: Host Subsystem Components and Descriptions
Related
Documentation
•
MX960 Router Overview on page 3
•
MX960 Chassis Description on page 9
•
MX960 Dense Port Concentrator Description on page 53
•
MX960 Modular Port Concentrator Description on page 89
•
MX960 SCB Description on page 107
•
MX960 Routing Engine Description on page 29
•
MX960 Flexible PIC Concentrator Description on page 62
•
MX960 Power System Overview on page 97
MX960 Routing Engine Description
If the host system is redundant, the backup Routing Engine is hot-removable and hot-insertable, but the master Routing Engine is hot-pluggable. A Routing Engine that is not redundant is hot-pluggable.
•
Supported Routing Engines on page 30
•
Routing Engine Function on page 30
•
Routing Engine Slots on page 30
•
Routing Engine Interface Ports on page 30
Copyright © 2017, Juniper Networks, Inc.
29
MX960 3D Universal Edge Router Hardware Guide
Supported Routing Engines
The MX960 router supports the following Routing Engines:
• RE-S-1300-2048 supported for Junos OS Release 8.2 and later.
• RE-S-2000-4096 supported for Junos OS Release 8.2 and later.
• RE-S-1800x2 supported for Junos OS Release 10.4 and later.
• RE-S-1800x4 supported for Junos OS Release 10.4 and later.
• RE-S-X6-64G supported for Junos OS Release 15.1F4, 16.1 and later.
• RE-S-X6-64G-LT
NOTE: The Routing Engine is equipped with limited encryption support only.
NOTE: If two Routing Engines are installed, they must both be the same hardware model.
Routing Engine Function
The Routing Engine runs the Junos OS. Software processes that run on the Routing Engine maintain the routing tables, manage the routing protocols used on the router, control the router interfaces, control some chassis components, and provide the interface for system management and user access to the router.
Routing Engine Slots
You can install one or two Routing Engines in the router. Each Routing Engine must be installed directly into an SCB. A USB port on the Routing Engine accepts a USB memory device that allows you to load Junos OS. The Routing Engines install into the front of the chassis in vertical slots directly into the SCBs labeled 0 and 1 . If two Routing Engines are installed, one functions as the master and the other acts as the backup. If the master
Routing Engine fails or is removed and the backup is configured appropriately, the backup takes over as the master.
On the MX960 router, a Routing Engine installed in SCB slot 2/6 receives no power and supplies no additional routing functions. If no SCB is installed in slot 2/6 , install a blank panel in the slot.
Routing Engine Interface Ports
Three ports, located on the right side of the routing engine, connect the Routing Engine to one or more external devices on which system administrators can issue Junos OS command-line interface (CLI) commands to manage the router.
The ports with the indicated labels function as follows:
30 Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
• AUX —Connects the Routing Engine to a laptop, modem, or other auxiliary device through a serial cable with an RJ-45 connector.
• CONSOLE —Connects the Routing Engine to a system console through a serial cable with an RJ-45 connector.
• ETHERNET or MGMT —Connects the Routing Engine through an Ethernet connection to a management LAN (or any other device that plugs into an Ethernet connection) for out-of-band management. The port uses an autosensing RJ-45 connector to support
10-Mbps or 100-Mbps connections. Two small LEDs on the right of the port indicate the connection in use: the LED flashes yellow or green for a 10-Mbps or 100-Mbps connection, and the LED is light green when traffic is passing through the port.
Related
Documentation
•
RJ-45 Connector Pinouts for MX Series Routing Engine AUX and CONSOLE Ports on page 149
•
RJ-45 Connector Pinouts for an MX Series Routing Engine ETHERNET Port on page 148
•
Replacing an MX960 Routing Engine on page 333
MX960 RE-S-1300 and RE-S-2000 Routing Engine LEDs
Each Routing Engine has four LEDs that indicate its status. The LEDs, labeled MASTER ,
HDD , ONLINE , and FAIL , are located directly on the faceplate of the Routing Engine.
describes the functions of the Routing Engine LEDs.
Table 13: Routing Engine LEDs
Label Color State Description
MASTER Blue
Green
On steadily Routing Engine is the Master.
Blinking Indicates activity on the hard disk drive.
HDD
ONLINE Green
FAIL Red
Blinking Routing Engine is transitioning online.
On steadily Routing Engine is functioning normally.
On steadily Routing Engine has failed.
Related
Documentation
•
MX960 Routing Engine Description on page 29
•
Replacing an MX960 Routing Engine on page 333
RE-S-1800 Routing Engine Description for MX Series
shows the Routing Engine 1800.
Copyright © 2017, Juniper Networks, Inc.
31
MX960 3D Universal Edge Router Hardware Guide
Figure 16: RE-S-1800 Front View
Auxiliary port
Ethernet port
SSD slot 1
SSD slot 2
Extractor clip
Console port
USB port
Reset button
Extractor clip
•
RE-S-1800 Routing Engine Components on page 32
•
RE-S-1800 Routing Engine Boot Sequence on page 33
RE-S-1800 Routing Engine Components
shows the RE-S-1800 Routing Engine.
Auxiliary port
Ethernet port
SSD slot 1
SSD slot 2
32
Extractor clip
Console port
USB port
Reset button
Extractor clip
Each Routing Engine consists of the following components:
• CPU—Runs Junos OS to maintain the router's routing tables and routing protocols..
• DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• USB port—Provides a removable media interface through which you can install Junos
OS manually. Junos OS supports USB version 1.0.
• CompactFlash card—Provides primary storage for software images, configuration files, and microcode. The CompactFlash card is fixed and is inaccessible from outside the router.
• Solid-state Drive (SSD)—Provides secondary storage for log files, memory dumps, and rebooting the system if the CompactFlash card fails.
• Interface ports—The AUX , CONSOLE , and ETHERNET provide access to management devices. Each Routing Engine has one 10/100/1000-Mbps Ethernet port for connecting to a management network, and two asynchronous serial ports—one for connecting to a console and one for connecting to a modem or other auxiliary device.
• EEPROM—Stores the serial number of the Routing Engine.
Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
• RESET button—Reboots the Routing Engine when pressed.
• ONLINE/OFFLINE button—Takes the Routing Engine online or offline when pressed.
• Extractor clips—Used for inserting and extracting the Routing Engine.
• Captive screws—Secure the Routing Engine in place.
NOTE: For specific information about Routing Engine components (for example, the amount of DRAM), issue the show chassis routing-engine command.
RE-S-1800 Routing Engine Boot Sequence
The router is shipped with Junos OS preinstalled on the Routing Engine. There are three copies of software:
• One copy on the CompactFlash card in the Routing Engine.
• One copy on the hard disk in the Routing Engine.
• One copy on a USB flash drive that can be inserted into the slot on the Routing Engine faceplate.
The Routing Engine boots from the storage media in this order: the USB device (if present), then the CompactFlash card, then the Solid State Disk (SSD), then the LAN. Normally, the router boots from the copy of the software on the CompactFlash card.
Related
Documentation
•
RJ-45 Connector Pinouts for MX Series Routing Engine AUX and CONSOLE Ports on page 149
•
RJ-45 Connector Pinouts for an MX Series Routing Engine ETHERNET Port on page 148
•
Replacing an MX960 Routing Engine on page 333
•
Supported Routing Engines by Router on page 40
RE-S-1800 Routing Engine LEDs
Each Routing Engine has four LEDs that indicate its status. The LEDs, labeled MASTER ,
STORAGE , ONLINE , and OK/FAIL , are located directly on the faceplate of the Routing
Engine.
describes the functions of the Routing Engine LEDs.
Table 14: Routing Engine LEDs
Label Color State Description
Blue On steadily Routing Engine is the Master.
MASTER
STORAGE Green Blinking Indicates activity on the SSD or Compact Flash.
Copyright © 2017, Juniper Networks, Inc.
33
MX960 3D Universal Edge Router Hardware Guide
Table 14: Routing Engine LEDs
(continued)
Label Color State Description
ONLINE Green
OK/FAIL Red
Blinking Routing Engine is transitioning online.
On steadily Routing Engine is functioning normally.
On steadily Routing Engine has failed.
Related
Documentation
• MX240 Routing Engine Description
• MX480 Routing Engine Description
•
MX960 Routing Engine Description on page 29
RE-S-X6-64G Routing Engine Description
shows the Routing Engine.
Figure 18: RE-S-X6-64G Routing Engine Front View
1— Extractor clips
2— Auxiliary port ( AUX )
3— Console port ( CONSOLE )
4— Management port ( MGMT )
5— LEDs— ONLINE, OK/FAIL, and MASTER
6—
7—
ONLINE/OFFLINE button
SSD LEDs— DISK1 and DISK2
8— Ports— USB1 and USB2
9— RESET button
10— SSD card slot cover
•
RE-S-X6-64G Routing Engine Components on page 34
•
RE-S-X6-64G Routing Engine Boot Sequence on page 35
RE-S-X6-64G Routing Engine Components
In routers with dual Routing Engines, both Routing Engines must be RE-S-X6-64G Routing
Engines.
Each RE-S-X6-64G Routing Engine (shown in
) consists of the following components:
• CPU—Runs Junos OS to maintain the routing tables and routing protocols.
• EEPROM—Stores the serial number of the Routing Engine.
34 Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
• DRAM—Provides storage for the routing and forwarding tables and for other Routing
Engine processes.
• One 10-Gigabit Ethernet interface between the Routing Engine and Switch Control
Board.
• Two 50-GB slim solid-state drives— SSD1 (primary) and SSD2 (secondary)—Provide storage for software images, configuration files, microcode, log files, and memory dumps. The Routing Engine reboots from SSD2 when boot from primary SSD fails.
• Two USB ports ( USB1 and USB2 )—Provide a removable media interface through which you can install Junos OS manually. The Junos OS supports USB versions 3.0, 2.0, and
1.1.
• Interface ports—The AUX , CONSOLE , and MGMT provide access to management devices. Each Routing Engine has one 10/100/1000-Mbps Ethernet port for connecting to a management network, and two asynchronous serial ports—one for connecting to a console and one for connecting to a modem or other auxiliary device.
• RESET button—Reboots the Routing Engine when pressed.
• ONLINE/OFFLINE button—Brings the Routing Engine online or takes it offline when pressed.
NOTE: The ONLINE/OFFLINE button must be pressed for a minimum of 4 seconds for the power off or power on to occur.
• Extractor clips—Control the locking system that secures the Routing Engine.
•
LEDs— “RE-S-X6-64G Routing Engine LEDs” on page 36
describes the functions of these LEDs.
NOTE: For specific information about Routing Engine components (for example, the amount of DRAM), issue the show vmhost hardware command.
RE-S-X6-64G Routing Engine Boot Sequence
Booting in a RE-S-X6-64G Routing Engine follows this sequence—the USB device, SSD1,
SSD2, LAN. SSD1 is the primary boot device. The boot sequence is tried twice for SSD1 and SSD2.
Related
Documentation
•
Routing Engine Specifications on page 37
•
Upgrading to the RE-S-X6-64G Routing Engine in a Redundant Host Subsystem on page 345
•
Upgrading to the RE-S-X6-64G Routing Engine in a Nonredundant Host Subsystem on page 351
Copyright © 2017, Juniper Networks, Inc.
35
MX960 3D Universal Edge Router Hardware Guide
RE-S-X6-64G Routing Engine LEDs
Each Routing Engine has five LEDs that indicate its status. The LEDs—labeled MASTER ,
DISK1 , DISK2 , ONLINE , and OK/FAIL —are located on the faceplate of the Routing Engine.
describes the functions of the Routing Engine LEDs.
Figure 19: RE-S-X6-64G Routing Engine LEDs
1— ONLINE LED
2— OK/FAIL LED
3— DISK1 LED
Table 15: RE-S-X6-64G Routing Engine LEDs
Label Color State
ONLINE Green Blinking slowly
DISK1
DISK2
OK/FAIL
MASTER
-
Green
-
Green
-
Green
Yellow
Blue
Blinking rapidly
Off
Blinking
Off
Blinking
Off
On steadily
On steadily
On steadily
4— DISK2 LED
5— ONLINE/OFFLINE button
6— MASTER LED
Description
Routing Engine is in the process of booting BIOS, and the host
OS.
Routing Engine is in the process of booting Junos OS.
Routing Engine is not online or not functioning normally.
Indicates presence of disk activity.
There is no disk activity.
Indicates presence of disk activity.
There is no disk activity.
Routing Engine is powering up.
Routing Engine is not powering up, which indicates failure.
This Routing Engine is the Master Routing Engine.
Related
Documentation
• MX240 Routing Engine Description
• MX480 Routing Engine Description
36 Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
•
MX960 Routing Engine Description on page 29
Routing Engine Specifications
lists the current specifications for Routing Engines supported on
M Series, MX Series, and T Series routers.
lists the specifications for end-of-life Routing Engines.
NOTE: For a list of the routing engines that are supported on the M Series,
MX Series, T Series, and PTX routers, see
NOTE: For information about PTX Series Routing Engine specifications, see
Routing Engines Supported on PTX Series Routers. For information about
Table 16: Routing Engine Specifications
Routing
Engine Processor Memory
Connection to PFEs
RE-400-768
RE-A-1000-2048 1.0-GHz
Pentium
RE-A-2000-4096 2.0-GHz
Pentium
RE-S-1300-2048 1.3-GHz
Pentium
RE-S-2000-4096 2.0-GHz
Pentium
RE-C1800
RE-C2600
400-MHz
Celeron
1.8-GHz
2.6-GHz
768 MB
2048 MB
4096 MB
2048 MB
4096 MB
8 GB
16 GB
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Disk
Fast Ethernet 40 GB hard disk
40 GB hard disk
40 GB hard disk
40 GB hard disk
40 GB hard disk
SSD
SSD
Media
First Junos OS
Support
1 GB
CompactFlash card
9.0
1 GB
CompactFlash card
8.1
1 GB
CompactFlash card
8.1
1 GB
CompactFlash card
8.2
1 GB
CompactFlash card
8.2
4 GB
CompactFlash card
T1600 router in a routing matrix: 9.6R2
Standalone T640 or
T1600 router:11.2
4 GB
CompactFlash card
TX Matrix Plus router: 9.6R2
Copyright © 2017, Juniper Networks, Inc.
37
MX960 3D Universal Edge Router Hardware Guide
Table 16: Routing Engine Specifications
(continued)
Routing
Engine
RE-A-1800x2
RE-S-1800x2
RE-S-1800x4
RE-S-MX104
Processor
1800-MHz
1800-MHz
1800-MHz
1.8-GHz
RE-B-1800x1-4G 1.73-GHz
RE-MX2000-1800x4 1800-GHz
RE-S-1800X4-32G-S 1800 Ghz
REMX2K-1800-32G-S 1800 Ghz
RE-S-X6-64G 2 Ghz
RE-S-X6-64G 2 Ghz
REMX2K-X8-64G 2.3 Ghz
REMX2008-X8-64G 2.3 Ghz
Memory
4 GB
4 GB
16 GB
32 GB
32 GB
64 GB
64 GB
64 GB
64 GB
Connection to PFEs
8 GB or 16 GB Gigabit
Ethernet
8 GB or 16 GB Gigabit
Ethernet
8GB or 16 GB Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Gigabit
Ethernet
Disk
32 GB SSD
32 GB SSD
32 GB SSD
–
64 GB SSD
Media
First Junos OS
Support
4 GB
CompactFlash card
10.4
4 GB
CompactFlash card
10.4
4 GB
CompactFlash card
8 GB NAND
Flash
10.4
13.2
4 GB
CompactFlash card
12.1R2, 11.4R4, and
12.2R1
32 GB SSD
32 GB SSD
32 GB SSD
Two 50-GB
SSDs
Two 50-GB
SSDs
-
Two 100-GB
SSDs
-
Two 50-GB
SSDs
-
4 GB Fixed
Internal
CompactFlash card
12.3R2
•
•
12.3R4
13.2R1
4 GB Fixed
Internal
CompactFlash card
4GB Fixed
Internal
CompactFlash card
-
•
•
12.3R4
13.2R1
15.1F4, 16.1
15.1F4, 16.1
15.1F5-S1, 16.1R2, and
16.2R1
15.1F7
38 Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
NOTE: Use shielded CAT5e cable for connecting the AUX , CONSOLE , and
MGMT ports in RE-S-X6-64G, REMX2K-X8-64G, and REMX2008-X8-64G
Routing Engines.
Table 17: End-of-Life Routing Engine Specifications
Routing
Engine Processor Memory
RE-333-256 333-MHz
Pentium II
256 MB
RE-333-768 333-MHz
Pentium II
768 MB
RE-600-512 600-MHz
Pentium III
512 MB
Connection to PFEs Disk
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
Media
6.4 GB hard disk
80 MB
CompactFlash card
3.4
6.4 GB hard disk
80 MB
CompactFlash card
3.4
30 GB hard disk
256 MB
CompactFlash card
5.4
First Junos OS
Support EOL Details
PSN-2003-01-063
PSN-2003-01-063
PSN-2004-07-019
RE-600-2048 600-MHz
Pentium III
2048 MB Fast
Ethernet
PSN-2008-02-018
RE-850-1536 850-MHz
Pentium III
1536 MB
RE-M40 200-MHz
Pentium
256 MB
RE-M40-333-768 333-MHz
Pentium II
768 MB
RE-M40-600-2048 600-MHz
Pentium III
2048 MB
RE-1600-2048 1.6-GHz
Pentium M
2048 MB
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
Fast
Ethernet
Gigabit
Ethernet
40 GB hard disk
1 GB
CompactFlash card
5.3
40 GB hard disk
1 GB
CompactFlash card
7.2
6.4 GB hard disk
80 MB
CompactFlash card
3.2
10 GB hard disk
80 MB
CompactFlash card
4.2
30 GB hard disk
128 MB
CompactFlash card
5.4
40 GB hard disk
1 GB
CompactFlash card
6.2
PSN-2011-04-226
FA-HW-0101-001
PSN-2003-01-063
PSN-2004-11-020
PSN-2008-02-019
NOTE: The memory in
indicates the amount of total memory. To determine the amount of available memory, issue the show chassis routing-engine CLI command.
Copyright © 2017, Juniper Networks, Inc.
39
MX960 3D Universal Edge Router Hardware Guide
On routers that accept two Routing Engines, you cannot mix Routing Engine types except for a brief period (one minute or so) during an upgrade or downgrade to two Routing
Engines of the same type.
Related
Documentation
•
Supported Routing Engines by Router on page 40
Supported Routing Engines by Router
The following tables list the Routing Engines that each router supports, the first supported release for the Routing Engine in the specified router, the management Ethernet interface, and the internal Ethernet interfaces for each Routing Engine.
•
M7i Routing Engines on page 40
•
M10i Routing Engines on page 41
•
M40e Routing Engines on page 41
•
M120 Routing Engines on page 42
•
M320 Routing Engines on page 42
•
MX5, MX10, MX40, and MX80 Routing Engine on page 43
•
MX104 Routing Engines on page 43
•
MX240 Routing Engines on page 43
•
MX480 Routing Engines on page 44
•
MX960 Routing Engines on page 45
•
MX2008 Routing Engines on page 46
•
MX2010 Routing Engines on page 46
•
MX2020 Supported Routing Engines on page 47
•
PTX3000 Routing Engines on page 47
•
PTX5000 Routing Engines on page 48
•
T320 Routing Engines on page 48
•
T640 Routing Engines on page 48
•
T1600 Routing Engines on page 49
•
T4000 Routing Engines on page 50
•
TX Matrix Routing Engines on page 50
•
TX Matrix Plus Routing Engines on page 51
•
TX Matrix Plus (with 3D SIBs) Routing Engines on page 51
M7i Routing Engines
lists the Routing Engines supported by the M7i router. The M7i router supports 32-bit Junos OS only.
40 Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 18: M7i Routing Engines
Model Number
Name in CLI
Output
RE-5.0
RE-400-768 (EOL details:
TSB16445 )
RE-850-1536 (EOL details:
TSB15553 )
RE-B-1800X1-4G
RE-850
RE-B-1800x1
First Supported 32-bit
Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
9.0
fxp0 fxp1
7.2
fxp0 fxp1
11.4R4
12.1R2
fxp0 em0
M10i Routing Engines
lists the Routing Engines supported by the M10i router. The M10i router supports 32-bit Junos OS only.
Table 19: M10i Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-400-768 (EOL details:
TSB16445 )
RE-5.0
9.0
fxp0
RE-850-1536 (EOL details:
TSB15553 )
RE-850 7.2
fxp0 fxp1 fxp2 fxp1 fxp2
RE-B-1800X1-4G RE-B-1800x1 11.4R4
12.1R2
fxp0 em0
M40e Routing Engines
lists the Routing Engines supported by the M40e router.
Table 20: M40e Routing Engines
Model Number Name in CLI Output
First Supported
Junos OS Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-600-2048 (EOL details:
TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
5.3
fxp0
RE-A-1000-2048 RE-A-1000 8.1
fxp0 fxp1 fxp2 fxp1 fxp2
Copyright © 2017, Juniper Networks, Inc.
41
MX960 3D Universal Edge Router Hardware Guide
M120 Routing Engines
lists the Routing Engines supported by the M120 router.
Table 21: M120 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-A-1000-2048 RE-A-1000 8.0R2
– fxp0
RE-A-2000-4096
RE-A-1800X2-8G
RE-A-1800X2-16G
RE-A-1800X4-16G
RE-A-2000
RE-A-1800x2
RE-A-1800x2
RE-A-1800x4
8.0R2
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
–
10.4
10.4
10.4
fxp0 fxp0 fxp0 fxp0 fxp1 fxp2 em0 em1 fxp1 fxp2 em0 bcm0 fxp1 fxp2
M320 Routing Engines
lists the Routing Engines supported by the M320 router.
Table 22: M320 Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-1600-2048 (EOL details: TSB14374 )
RE-4.0
6.2
– fxp0 fxp1 fxp2
RE-A-2000-4096
RE-A-1800X2-8G
RE-A-2000
RE-A-1800x2
8.1
•
•
11.4R5
12.1R3
–
10.4
fxp0 fxp0 em0 bcm0 em0 bcm0
42 Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 22: M320 Routing Engines
(continued)
Model Number
RE-A-1800X2-16G
Name in CLI
Output
RE-A-1800x2
First Supported
32-bit Junos OS
Release
•
•
11.4R5
12.1R3
First
Supported
64-bit Junos
OS Release
10.4
10.4
Management
Ethernet
Interface
Internal Ethernet
Interface fxp0 fxp0 em0 bcm0 em0 em1
RE-A-1800X4-8G RE-A-1800X4 •
•
•
11.4R5
12.1R3
12.2
MX5, MX10, MX40, and MX80 Routing Engine
lists the Routing Engines supported by the MX5, MX10, MX40, and
MX80 routers.
Table 23: MX5, MX10, MX40, and MX80 Routing Engine
Model
Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface Internal Ethernet Interface
Built-in Routing
Engine
Routing Engine
RE-MX80
12.3
fxp0 em0 em1
NOTE: em1 is used to communicate with the
MS-MIC when it is inserted.
MX104 Routing Engines
lists the Routing Engines supported by MX104 routers.
Table 24: MX104 Routing Engines
Model
Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-S-MX104 Routing Engine 13.2
– fxp0 fxp1 fxp2
MX240 Routing Engines
lists the Routing Engines supported by MX240 routers.
Copyright © 2017, Juniper Networks, Inc.
43
MX960 3D Universal Edge Router Hardware Guide
Table 25: MX240 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
RE-S-1300-2048 (EOL details: TSB16556
RE-S-1300 9.0
–
RE-S-2000-4096 (EOL details: TSB16735
RE-S-1800X2-8G (EOL details: TSB16556
RE-S-1800x2-16G (EOL details: TSB16556
RE-S-1800X4-8G
RE-S-1800X4-16G
RE-S-1800X4-32G-S
RE-S-X6-64G
RE-S-2000
RE-S-1800x2
RE-S-1800x2
RE-S-1800X4
RE-S-1800x4
RE-S-1800X4
RE-S-2X00x6
9.0
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
•
•
12.3R4
13.2R1
–
–
10.4
10.4
10.4
10.4
•
•
12.3R4
13.2R1
15.1F4
16.1R1
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 fxp0 fxp1 fxp2 fxp1 fxp2 fxp0 fxp0 fxp0 fxp0 fxp0 fxp0 em0 em1 em0 em1 em0 em1 em0 em1 em0, em1 ixlv0, igb0
MX480 Routing Engines
lists the Routing Engines supported by MX480 routers.
Table 26: MX480 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal Ethernet
Interface
RE-S-1300-2048
(EOL details:
TSB16556
RE-S-1300
RE-S-2000-4096
(EOL details:
TSB16735
RE-S-2000
8.4
8.4
–
– fxp0 fxp0 fxp1 fxp2 fxp1 fxp2
44 Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 26: MX480 Supported Routing Engines
(continued)
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
RE-S-1800X2-8G
(EOL details:
TSB16556
RE-S-1800x2
RE-S-1800X2-16G
(EOL details:
TSB16556
RE-S-1800x2
RE-S-1800X4-8G RE-S-1800X4
RE-S-1800X4-16G RE-S-1800x4
RE-S-1800X4-32G-S RE-S-1800X4
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
•
•
12.3R4
13.2R1
10.4
10.4
10.4
10.4
•
•
12.3R4
13.2R1
fxp0 fxp0 fxp0 fxp0 fxp0
RE-S-X6-64G RE-S-2X00x6 – 15.1F4
16.1R1
fxp0
MX960 Routing Engines
lists the Routing Engines supported by MX960 routers.
Table 27: MX960 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-S-1300-2048 (EOL details: TSB16556
RE-S-1300 8.2
– fxp0
RE-S-2000-4096 (EOL details: TSB16735
RE-S-1800X2-8G (EOL details: TSB16556
RE-S-1800X2-16G (EOL details: TSB16556
RE-S-2000
RE-S-1800x2
RE-S-1800x2
8.2
•
•
11.4R5
12.1R3
•
•
11.4R5
12.1R3
–
10.4
10.4
fxp0 fxp0 fxp0 em0 em1 em0 em1 fxp1 fxp2 fxp1 fxp2
Internal Ethernet
Interface em0 em1 em0 em1 em0 em1 em0 em1 em0 em1 ixlv0, igb0
Copyright © 2017, Juniper Networks, Inc.
45
MX960 3D Universal Edge Router Hardware Guide
Table 27: MX960 Supported Routing Engines
(continued)
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First
Supported
64-bit Junos
OS Release
RE-S-1800X4-8G RE-S-1800x4 •
•
11.4R5
12.1R3
10.4
RE-S-1800X4-16G
RE-S-1800X4-32G-S
RE-S-X6-64G
RE-S-1800x4
RE-S-1800x4
RE-S-2X00x6
•
•
11.4R5
12.1R3
•
•
12.3R4
13.2R1
–
10.4
•
•
12.3R4
13.2R1
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 fxp0 em0 em1 em0 em1 fxp0 fxp0 em0 em1 ixlv0, igb0 15.1F4
16.1R1
MX2008 Routing Engines
lists the Routing Engines supported by MX2008 routers.
Table 28: MX2008 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
REMX2008-X8-64G RE-MX2008-X8-64G 15.1F7
fxp0 ixlv0 ixlv1
MX2010 Routing Engines
lists the Routing Engines supported by MX2010 routers.
Table 29: MX2010 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-MX2000-1800X4 RE-S-1800x4 12.3R2
fxp0
REMX2K-1800-32G-S RE-S-1800x4 •
•
12.3R4
13.2R1
fxp0 em0 em1 em0 em1
46 Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 29: MX2010 Supported Routing Engines
(continued)
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
REMX2K-X8-64G RE-S-2X00x8 •
•
•
15.1F5-S1
16.1R2
16.2R1
fxp0
Internal
Ethernet
Interface ixlv0 ixlv1
MX2020 Supported Routing Engines
lists the Routing Engines supported by MX2020 routers.
Table 30: MX2020 Supported Routing Engines
Model Number
Name in CLI
Output
First Supported 64-bit Junos
OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-MX2000-1800X4 RE-S-1800x4 12.3R2
fxp0 em0 em1
REMX2K-1800-32G-S RE-S-1800x4 •
•
12.3R4
13.2R1
fxp0
REMX2K-X8-64G RE-S-2X00x8 •
•
•
15.1F5-S1
16.1R2
16.2R1
fxp0 em0 em1 ixlv0 ixlv1
PTX3000 Routing Engines
lists the Routing Engines supported on the PTX3000.
RCB-PTX-X6-32G
NOTE: The PTX3000 supports 64-bit Junos OS only.
Table 31: PTX3000 Routing Engines
Model Number Name in CLI Output
First Supported
Junos OS Release
RE-DUO-C2600-16G RE-DUO-2600 13.2R2
RE-PTX-2X00x6 16.1R4
Management
Ethernet Interface em0
Internal Ethernet
Interface em0 ixgbe0 ixgbe1 ixlv0 ixlv1
Copyright © 2017, Juniper Networks, Inc.
47
MX960 3D Universal Edge Router Hardware Guide
PTX5000 Routing Engines
lists the Routing Engines supported on the PTX5000.
NOTE: The PTX5000 supports 64-bit Junos OS only.
Table 32: PTX5000 Routing Engines
Model Number
Name in CLI
Output
RE-DUO-C2600-16G RE-DUO-2600
RE-PTX-X8-64G RE-PTX-2X00x8
First Supported Junos OS
Release
12.1X48
12.3
13.2
NOTE: The PTX5000 does not support Junos OS Releases 12.1,
12.2, or 13.1.
15.1F4
16.1R1
Management
Ethernet
Interface em0 em0
Internal Ethernet
Interface ixgbe0 ixgbe1 ixlv0 ixlv1 em1
T320 Routing Engines
lists the Routing Engines supported by the T320 router.
Table 33: T320 Routing Engines
Model Number Name in CLI Output
First Supported
32-bit Junos OS
Release
Management
Ethernet Interface
Internal Ethernet
Interface
RE-600-2048 (EOL details:
TSB14373 )
RE-3.0
or RE-3.0
(RE-600)
5.3
fxp0
RE-1600-2048 (EOL details:
TSB14374
RE-4.0
6.2
fxp0 fxp1 fxp2 fxp1 fxp2
RE-A-2000-4096 RE-A-2000 8.1
fxp0 fxp1 fxp2
T640 Routing Engines
lists the Routing Engines supported by the T640 router.
48 Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 34: T640 Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
First Supported 64-bit
Junos OS Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or
RE-3.0
(RE-600)
RE-1600-2048 (EOL details: TSB14374
RE-4.0
5.3
6.2
–
– fxp0 fxp0 fxp1 fxp2
RE-A-2000-4096 RE-A-2000 8.1
– fxp0 fxp1 fxp2 em0 bcm0
RE-DUO-C1800-8G RE-DUO-1800 32-bit Junos OS on a standalone T640 router:
11.2
32-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
64-bit Junos OS on a standalone T640 router:
11.3
em0
64-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
RE-DUO-C1800-16G RE-DUO-1800 32-bit Junos OS on a standalone T640 router:
11.4R2
64-bit Junos OS on a standalone T640 router:
11.4R2
em0
32-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
64-bit Junos OS on a
T640 router in a routing matrix: 11.4R9
bcm0 em1 bcm0 em1
T1600 Routing Engines
lists the Routing Engines supported by the T1600 router.
NOTE: (Two RE-DUO-C1800-8G or two RE-DUO-C1800-16G are required to connect to a Routing Matrix)
Table 35: T1600 Routing Engines
Model Number
Name in CLI
Output
First Supported 32-bit
Junos OS Release
8.5
RE-600-2048 (EOL details: TSB14373 )
RE-3.0
or
RE-3.0
(RE-600)
RE-1600-2048 (EOL details: TSB14374
RE-4.0
(RE-1600)
8.5
First Supported
64-bit Junos OS
Release
–
–
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 fxp1 fxp2 fxp0 fxp1 fxp2
Copyright © 2017, Juniper Networks, Inc.
49
MX960 3D Universal Edge Router Hardware Guide
Table 35: T1600 Routing Engines
(continued)
Model Number
RE-A-2000-4096
Name in CLI
Output
RE-A-2000
First Supported 32-bit
Junos OS Release
8.5
First Supported
64-bit Junos OS
Release
–
RE-DUO-C1800-8G RE-TXP-LCC or
RE-DUO-1800
32-bit Junos OS on a T1600 router in a routing matrix: 9.6
NOTE: Junos OS Releases
9.6 through 10.4 support
RE-DUO-C1800-8G only during upgrade to a line-card chassis (LCC) in a routing matrix.
32-bit Junos OS on a standalone T1600 router: 11.1
64-bit Junos OS on a
T1600 router in a routing matrix: 9.6
64-bit Junos OS on a standalone T1600 router: 11.1
em0
RE-DUO-C1800-16G RE-DUO-1800 32-bit Junos OS on a standalone T1600 router:
11.4R2
32-bit Junos OS on a T1600 router in a routing matrix:
11.4R2
64-bit Junos OS on a standalone T1600 router: 11.4R2
64-bit Junos OS on a
T1600 router in a routing matrix: 11.4R2
em0
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 em0 bcm0 bcm0 em1 bcm0 em1
T4000 Routing Engines
lists the Routing Engines supported by the T4000 router.
NOTE: The T4000 router supports 64-bit Junos OS only.
Table 36: T4000 Routing Engines
Model Number
Name in CLI
Output
RE-DUO-C1800-8G RE-DUO-1800
RE-DUO-C1800-16G RE-DUO-1800
First Supported 64-bit Junos OS
Release
Management
Ethernet
Interface
Standalone T4000 router: 12.1
T4000 router in a routing matrix: 13.1
em0
Standalone T4000 router: 12.1R2
T4000 router in a routing matrix: 13.1
em0
Internal Ethernet
Interface bcm0 em1 bcm0 em1
TX Matrix Routing Engines
lists the Routing Engines supported by the TX Matrix router.
50 Copyright © 2017, Juniper Networks, Inc.
Chapter 5: Host Subsystem Components and Descriptions
Table 37: TX Matrix Routing Engines
Model Number
RE-600-2048 (EOL details: TSB14373 )
RE-1600-2048 (EOL details: TSB14374
RE-A-2000-4096
RE-DUO-C1800-8G
RE-DUO-C1800-16G
Name in CLI
Output
RE-3.0
or RE-3.0
(RE-600)
RE-A-2000
RE-DUO-1800
RE-DUO-1800
First
Supported
32-bit Junos
OS Release
7.0
RE-4.0 (RE-1600) 7.0
8.5
11.4R9
11.4R9
First
Supported
64-bit Junos
OS Release
–
–
–
11.4R9
11.4R9
Management
Ethernet
Interface
Internal
Ethernet
Interface fxp0 fxp0 fxp1 fxp2 fxp1 fxp2 fxp0 em0 em0 em0 bcm0 bcm0 em1 bcm0 em1
TX Matrix Plus Routing Engines
lists the Routing Engines supported by the TX Matrix Plus router.
Table 38: TX Matrix Plus Routing Engines
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-DUO-C2600-16G RE-TXP-SFC or
RE-DUO-2600
32-bit Junos OS: 9.6
64-bit Junos OS: 11.4
em0 ixgbe0 ixgbe1
TX Matrix Plus (with 3D SIBs) Routing Engines
lists the Routing Engines supported by the TX Matrix Plus router with 3D SIBs.
Table 39: Routing Engines on TX Matrix Plus with 3D SIBs
Model Number
Name in CLI
Output
First Supported
32-bit Junos OS
Release
First Supported
64-bit Junos OS
Release
Management
Ethernet
Interface
Internal
Ethernet
Interface
RE-DUO-C2600-16G RE-TXP-SFC or
RE-DUO-2600
64-bit Junos OS: 11.4
em0 ixgbe0 ixgbe1
Copyright © 2017, Juniper Networks, Inc.
51
MX960 3D Universal Edge Router Hardware Guide
Related
Documentation
•
Routing Engine Specifications on page 37
• Understanding Internal Ethernet Interfaces
• Understanding Management Ethernet Interfaces
52 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 6
Line Card Components and Descriptions
•
Interface Modules—DPCs on page 53
•
Interface Modules—FPCs and PICs on page 62
•
Interface Modules—MPCs and MICs on page 69
Interface Modules—DPCs
•
MX960 Dense Port Concentrator Description on page 53
•
MX960 Dense Port Concentrator LEDs on page 56
•
DPCs Supported on MX240, MX480, and MX960 Routers on page 56
•
MX960 DPC Port and Interface Numbering on page 59
MX960 Dense Port Concentrator Description
A Dense Port Concentrator (DPC) is optimized for Ethernet density.
shows two examples of DPCs. For a list of the DPCs supported, see the MX Series Interface
Module Reference .
Copyright © 2017, Juniper Networks, Inc.
53
MX960 3D Universal Edge Router Hardware Guide
Figure 20: Typical DPCs Supported by the Router
DPC 40x1GE DPC 4x10GE
OK/FAIL
2/0 2/5
OK/FAIL
0/0
TUNNEL
LINK
1/0 1/5
3/0 3/5
1/0
TUNNEL
LINK
2/0
TUNNEL
LINK
3/0
TUNNEL
LINK
The DPC assembly combines packet forwarding and Ethernet interfaces on a single board, with either two or four 10-Gbps Packet Forwarding Engines. Each Packet Forwarding
Engine consists of one I-chip for Layer 3 processing and one Layer 2 network processor.
The DPCs interface with the power supplies and Switch Control Boards (CBs).
The router has 11 dedicated DPC slots. DPCs install vertically in the front of the router
(see
Figure 21 on page 55 ). The dedicated DPC slots are numbered
0 though 5 , and 7 though 11 , left to right. An additional multifunction slot labeled 2/6 supports either an
SCB or a DPC. A DPC can be installed in any slot that supports DPCs. You can install any combination of DPC types in the router.
If a slot is not occupied by a DPC, a DPC blank panel must be installed to shield the empty slot and to allow cooling air to circulate properly through the router.
DPCs are hot-removable and hot-insertable. When you install a DPC in an operating router, the Routing Engine downloads the DPC software, the DPC runs its diagnostics, and the Packet Forwarding Engines housed on the DPC are enabled. Forwarding on other
DPCs continues uninterrupted during this process.
54 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Figure 21: DPCs Installed Vertically in the MX960 Router
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK
FAIL
2 6
ONLINE
OK
FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK
FAIL
NC C NO
NC
OK FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK
FAIL
11
ONLINE
DPC
OK/FAIL
2/0 2/5
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1/0 1/5
3/0 3/5
DPC Components
Each DPC consists of the following components:
• DPC cover, which functions as a ground plane and a stiffener.
• Fabric interfaces.
• Two Gigabit Ethernet interfaces that allow control information, route information, and statistics to be sent between the Routing Engine and the CPU on the DPCs.
• Two interfaces from the SCBs that enable the DPCs to be powered on and controlled.
• Physical DPC connectors.
• Two or four Packet Forwarding Engines.
• Midplane connectors and power circuitry.
• Processor subsystem, which includes a 1.2-GHz CPU, system controller, and 1 GB of
SDRAM.
• Online button—Takes the DPC online or offline when pressed.
• LEDs on the DPC faceplate. For more information about LEDs on the DPC faceplate, see the MX Series Interface Module Reference .
Copyright © 2017, Juniper Networks, Inc.
55
MX960 3D Universal Edge Router Hardware Guide
Two LEDs, located on the craft interface above the DPC, display the status of the DPC and are labeled OK and FAIL .
Related
Documentation
•
MX960 Dense Port Concentrator LEDs on page 56
•
MX960 Field-Replaceable Units on page 263
•
Replacing an MX960 DPC on page 355
MX960 Dense Port Concentrator LEDs
Two LEDs, located on the craft interface above the DPC, display the status of the DPC and are labeled OK and FAIL . For more information about the DPC LEDs on the craft interface, see
“MX960 DPC and MPC LEDs on the Craft Interface” on page 18
.
Each DPC also has LEDs located on the faceplate. For more information about LEDs on the DPC faceplate, see the “LEDs” section for each DPC in the MX Series Interface Module
Reference .
Related
Documentation
•
MX960 Dense Port Concentrator Description on page 53
•
Maintaining MX960 DPCs on page 450
•
Replacing an MX960 DPC on page 355
DPCs Supported on MX240, MX480, and MX960 Routers
NOTE: These DPCs have all been announced as End of Life (EOL). The End of Support (EOS) milestone dates for each model are published at http://www.juniper.net/support/eol/mseries_hw.html
.
lists the DPCs supported by the MX240, MX480, and MX960 routers.
Table 40: DPCs Supported in MX240, MX480, and MX960 Routers
DPC Name
DPC Model
Number Ports
Maximum
Throughput per DPC
First Junos
OS Release
Gigabit Ethernet
Gigabit Ethernet DPC with SFP 40 Gbps 8.2
Gigabit Ethernet Enhanced DPC with SFP
DPC-R-40GE-SFP
EOL (see
PSN-2009-06-400 )
40
DPCE-R-40GE-SFP
EOL (see
PSN-TSB16810 )
40 40 Gbps 8.4
56 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 40: DPCs Supported in MX240, MX480, and MX960 Routers
(continued)
DPC Name
DPC Model
Number Ports
Maximum
Throughput per DPC
First Junos
OS Release
40 Gbps 8.4
Gigabit Ethernet Enhanced Ethernet Services DPC with SFP DPCE-X-40GE-SFP 40
EOL (see
PSN-TSB16810 )
Gigabit Ethernet Enhanced Queuing Ethernet Services DPC with SFP
DPCE-X-Q-40GE-SFP 40
EOL (see
PSN-2013-02-851 )
Gigabit Ethernet Enhanced Queuing IP Services DPCs with
SFP
DPCE-R-Q-20GE-SFP 20
EOL (see
PSN-2013-02-851 )
Gigabit Ethernet Enhanced Queuing IP Services DPCs with
SFP
DPCE-R-Q-40GE-SFP 40
EOL (see
PSN-2011-07-314 )
10-Gigabit Ethernet DPC with XFP DPC-R-4XGE-XFP
EOL (see
PSN-2009-06-400 )
4
10-Gigabit Ethernet
10-Gigabit Ethernet Enhanced DPCs with XFP
10-Gigabit Ethernet Enhanced DPCs with XFP
DPCE-R-2XGE-XFP
EOL (see
PSN-2011-02-314 )
2
DPCE-R-4XGE-XFP
EOL (see
PSN-TSB16810 )
4
10-Gigabit Ethernet Enhanced Ethernet Services DPC with
XFP
DPCE-X-4XGE-XFP
EOL (see
PSN-TSB16810 )
4
10-Gigabit Ethernet Enhanced Queuing Ethernet Services
DPC with XFP
DPCE-X-Q-4XGE-XFP 4
EOL (see
PSN-2013-02-851 )
10-Gigabit Ethernet Enhanced Queuing IP Services DPC with XFP
DPCE-R-Q-4XGE-XFP 4
EOL (see
PSN-2011-02-314 )
40 Gbps
20 Gbps
40 Gbps
40 Gbps
20 Gbps
40 Gbps
40 Gbps
40 Gbps
40 Gbps
8.5
9.1
8.5
8.2
9.1
8.4
8.4
8.5
8.5
Copyright © 2017, Juniper Networks, Inc.
57
MX960 3D Universal Edge Router Hardware Guide
Table 40: DPCs Supported in MX240, MX480, and MX960 Routers
(continued)
DPC Name
DPC Model
Number Ports
Maximum
Throughput per DPC
First Junos
OS Release
Mulit-Rate Ethernet
Multi-Rate Ethernet Enhanced DPC with SFP and XFP DPCE-R-20GE-2XGE 22
EOL (see
PSN-TSB16810 )
Multi-Rate Ethernet Enhanced Ethernet Services DPC with
SFP and XFP
DPCE-X-20GE-2XGE 22
EOL (see
PSN-2011-02-314 )
Multi-Rate Ethernet Enhanced Queuing IP Services DPC with SFP and XFP
DPCE-R-Q-20GE-2XGE 22
EOL (see
PSN-TSB16810 )
Tri-Rate Ethernet
Tri-Rate Enhanced DPC
Tri-Rate Enhanced Ethernet Services DPC
DPCE-R-40GE-TX
EOL (see
PSN-2013-02-851 )
40
DPCE-X-40GE-TX
EOL (see
PSN-2011-07-315.
)
40
Services
Multiservices DPC MS-DPC
EOL (see
PSN-TSB16812 )
40 Gbps
40 Gbps
40 Gbps
40 Gbps
40 Gbps
2 (Not supported)
–
9.2
9.2
9.3
9.1
9.1
9.3
Related
Documentation
• MX Series DPC Overview
• Protocols and Applications Supported by DPCs and Enhanced DPCs (DPC and DPCE-R)
• Protocols and Applications Supported by Enhanced Ethernet Services DPCs (DPCE-X)
• Protocols and Applications Supported by Enhanced Queuing IP Services DPCs
(DPCE-R-Q)
• Protocols and Applications Supported by Enhanced Queuing Ethernet Services DPCs
(DPCE-X-Q)
• Protocols and Applications Supported by the Multiservices DPC (MS-DPC)
58 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
MX960 DPC Port and Interface Numbering
Each port on a DPC corresponds to a unique interface name in the CLI.
In the syntax of an interface name, a hyphen ( ) separates the media type from the DPC number (represented as an FPC in the CLI). The DPC slot number corresponds to the first number in the interface. The second number in the interface corresponds to the logical
PIC number. The last number in the interface matches the port number on the DPC.
Slashes ( / ) separate the DPC number from the logical PIC number and port number.
type fpc / pic / port
• type —Media type, which identifies the network device. For example:
• ge—Gigabit Ethernet interface
• so—SONET/SDH interface
• xe—10-Gigabit Ethernet interface
For a complete list of media types, see Interface Naming Overview .
• fpc —Slot in which the DPC is installed. On the MX960 router, the DPCs are represented in the CLI as FPC 0 through FPC 11 .
• pic —Logical PIC on the DPC. The number of logical PICs varies depending on the type of DPC. For example, a:
• 20-port Gigabit Ethernet DPC has two logical PICs, numbered 0 through 1.
• 40-port Gigabit Ethernet DPC has four logical PICs, numbered 0 through 3.
• 2-port 10-Gigabit Ethernet DPC has two logical PICs, numbered 0 through 1.
• 4-port 10-Gigabit Ethernet DPC has four logical PICs, numbered 0 through 3.
For more information on specific DPCs, see
“DPCs Supported on MX240, MX480, and
in the MX Series Interface Module Reference .
• port —Port number.
The MX960 router supports up to twelve DPCs that install vertically and are numbered 0 through 11 from left to right.
shows a 40-port Gigabit Ethernet DPC with SFP installed in slot 3 on the MX960 router.
Copyright © 2017, Juniper Networks, Inc.
59
MX960 3D Universal Edge Router Hardware Guide
60 ge-3/1/0 ge-3/1/1 ge-3/1/2 ge-3/1/3 ge-3/1/4 ge-3/1/5 ge-3/1/6 ge-3/1/7 ge-3/1/8 ge-3/1/9 ge-3/0/0 ge-3/0/1 ge-3/0/2 ge-3/0/3 ge-3/0/4 ge-3/0/5 ge-3/0/6 ge-3/0/7 ge-3/0/8 ge-3/0/9
Figure 22: MX960 DPC Interface Port Mapping
MIC-3D-40GE-TX ge-3/3/0 ge-3/3/1 ge-3/3/2 ge-3/3/3 ge-3/3/4 ge-3/3/5 ge-3/3/6 ge-3/3/7 ge-3/3/8 ge-3/3/9 ge-3/2/0 ge-3/2/1 ge-3/2/2 ge-3/2/3 ge-3/2/4 ge-3/2/5 ge-3/2/6 ge-3/2/7 ge-3/2/8 ge-3/2/9
0 1 2 3
0 1 2 3
4 5 0 1 2 6 7 8 9 10 11
The DPC contains four logical PICs, numbered PIC 0 through PIC 3 in the CLI. Each logical
PIC contains 10 ports numbered 0 through 9 .
The show chassis hardware command output displays a 40-port Gigabit Ethernet DPC with SFP ( DPCE-R-40GE-SFP ) installed in DPC slot 3 . The DPC is shown as FPC 3 and the DPC’s four logical PICs — 10x 1GE(LAN) — are shown as PIC 0 through PIC 3 .
user@host> show chassis hardware
...
FPC 3 REV 07 750-018122 KB8222 DPCE 40x 1GE R
CPU REV 06 710-013713 KA9010 DPC PMB
PIC 0 BUILTIN BUILTIN 10x 1GE(LAN)
Xcvr 0 REV 01 740-011782 PCH2NU4 SFP-SX
Xcvr 1 REV 01 740-011782 PCH2P4R SFP-SX
Xcvr 2 REV 01 740-011782 PCH2NYL SFP-SX
Xcvr 3 REV 01 740-011782 PCH2UW6 SFP-SX
Xcvr 4 REV 01 740-011782 PCH2P4N SFP-SX
Xcvr 5 REV 01 740-011782 PCH2UME SFP-SX
Xcvr 6 REV 01 740-011613 PCE1H5P SFP-SX
Xcvr 7 REV 01 740-011782 PCH2UFG SFP-SX
Xcvr 8 REV 02 740-011613 AM0947SEYU2 SFP-SX
Xcvr 9 REV 02 740-011613 AM0947SEYTQ SFP-SX
PIC 1 BUILTIN BUILTIN 10x 1GE(LAN)
Xcvr 0 REV 01 740-011782 PCH2UYF SFP-SX
Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Xcvr 1 REV 01 740-011782 PCH2P4L SFP-SX
Xcvr 2 REV 01 740-011782 PCH2UCL SFP-SX
Xcvr 3 REV 01 740-011782 PCH2P4X SFP-SX
Xcvr 4 REV 01 740-011782 PCH2P1E SFP-SX
Xcvr 5 REV 01 740-011782 PCH2UD2 SFP-SX
Xcvr 6 REV 01 740-011782 PCH2PLC SFP-SX
Xcvr 7 REV 01 740-011782 PCH2UDJ SFP-SX
Xcvr 8 REV 02 740-011613 AM0947SEX7S SFP-SX
PIC 2 BUILTIN BUILTIN 10x 1GE(LAN)
Xcvr 0 REV 01 740-011782 PCH2NV7 SFP-SX
Xcvr 1 REV 01 740-011782 PCH2P6Q SFP-SX
Xcvr 2 REV 01 740-011782 PCH2NUG SFP-SX
Xcvr 3 REV 01 740-011782 PCH2P10 SFP-SX
Xcvr 9 REV 02 740-011613 AM0947SEXBT SFP-SX
PIC 3 BUILTIN BUILTIN 10x 1GE(LAN)
Xcvr 0 REV 01 740-011782 PCH2PL4 SFP-SX
Xcvr 1 REV 01 740-011782 PCH2P1K SFP-SX
Xcvr 2 REV 01 740-011782 PCH2PLM SFP-SX
Xcvr 3 REV 01 740-011782 PCH2UFF SFP-SX
Xcvr 8 REV 02 740-011613 AM1003SFV5S SFP-SX
Xcvr 9 REV 02 740-011613 AM0947SEXBX SFP-SX
...
The show interfaces terse command output displays the Gigabit Ethernet interfaces that correspond to the 40 ports located on the DPC.
user@host> show interfaces terse ge-3*
Interface Admin Link Proto Local Remote ge-3/0/0 up up ge-3/0/1 up down ge-3/0/2 up up ge-3/0/3 up up ge-3/0/4 up up ge-3/0/5 up up ge-3/0/6 up up ge-3/0/7 up up ge-3/0/8 up up ge-3/0/9 up up ge-3/1/0 up down ge-3/1/1 up down ge-3/1/2 up down ge-3/1/3 up down ge-3/1/4 up up ge-3/1/5 up up ge-3/1/6 up up ge-3/1/7 up up ge-3/1/8 up up ge-3/1/9 up down ge-3/2/0 up down ge-3/2/1 up down ge-3/2/2 up down ge-3/2/3 up down ge-3/2/4 up down ge-3/2/5 up down ge-3/2/6 up down ge-3/2/7 up down ge-3/2/8 up down ge-3/2/9 up down ge-3/3/0 up down
Copyright © 2017, Juniper Networks, Inc.
61
MX960 3D Universal Edge Router Hardware Guide ge-3/3/1 up down ge-3/3/2 up down ge-3/3/3 up down ge-3/3/4 up down ge-3/3/5 up down ge-3/3/6 up down ge-3/3/7 up down ge-3/3/8 up down ge-3/3/9 up down
Related
Documentation
•
MX960 Router Hardware and CLI Terminology Mapping on page 12
Interface Modules—FPCs and PICs
•
MX960 Flexible PIC Concentrator Description on page 62
•
MX960 Flexible PIC Concentrator (FPC) LEDs on page 65
•
FPCs Supported by MX240, MX480, and MX960 Routers on page 65
•
MX960 PIC Description on page 66
•
•
MX960 PIC Port and Interface Numbering on page 66
•
PICs Supported by MX240, MX480, and MX960 Routers on page 68
MX960 Flexible PIC Concentrator Description
A Flexible PIC Concentrator (FPC) occupies two Dense Port Concentrator (DPC) slots on an MX Series router. The MX960 router has 11 dedicated DPC slots and one multifunction slot that supports either a DPC, FPC, or Switch Control Board (SCB). The dedicated DPC slots are numbered 0 though 5 , and 7 though 11 , left to right. The multifunction slot is labeled 2/6 . Up to six FPCs can be installed vertically in any two slots that support FPCs (see
). The interface corresponds to the lowest numbered DPC slot for which the FPC is installed.
62 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Figure 23: FPC Installed in the MX960 Router Chassis
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ALAR M
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
shows the typical FPCs supported on the MX960 router.
Copyright © 2017, Juniper Networks, Inc.
63
MX960 3D Universal Edge Router Hardware Guide
Figure 24: Typical FPCs Supported on the MX960 Router
MX-FPC2 FPC3
64
If a slot is not occupied by a DPC, an FPC, or an SCB, a blank panel must be installed to shield the empty slot and to allow cooling air to circulate properly through the router.
Each FPC supports up to two PICs. On an FPC2, one Packet Forwarding Engine receives incoming packets from the PICs installed on the FPC and forwards them through the switch planes to the appropriate destination port. On an FPC3, two Packet Forwarding
Engines receive incoming packets from the PICs installed on the FPC and forward them through the switch planes to the appropriate destination port. The FPCs interface with the power supplies and SCBs.
FPCs are hot-removable and hot-insertable, as described in
Redundancy” on page 12 . When you install an FPC into a functioning router, the Routing
Engine downloads the FPC software, the FPC runs its diagnostics, and the PICs, housed on the FPC, are enabled. Forwarding continues uninterrupted during this process. When you remove or install an FPC, packet forwarding between other DPCs or FPCs is not affected.
FPC Components
Each FPC consists of the following components:
• FPC card carrier, which includes two PIC slots
• Up to two Packet Forwarding Engines, each consisting of one I-chip for Layer 3 processing and one Layer 2 network processor
• Midplane connectors and power circuitry
• Processor subsystem (PMB), which includes a 1.2-GHz CPU, system controller, 1 GB of
SDRAM, and two Gigabit Ethernet interfaces
Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
• Two LEDs, located on the craft interface above the FPC, that display the status of the
FPC and are labeled OK and FAIL
• FPC online/offline button, located on the craft interface above the FPC
Related
Documentation
•
MX960 Flexible PIC Concentrator (FPC) LEDs on page 65
• MX960 FPC Terminology
•
Replacing an MX960 FPC on page 361
•
Maintaining MX960 FPCs on page 455
•
Troubleshooting the MX960 FPCs on page 492
MX960 Flexible PIC Concentrator (FPC) LEDs
Two LEDs, located on the craft interface above the FPC, that display the status of the
FPC and are labeled OK and FAIL . For more information about the FPC LEDs located on the craft interface, see
“MX960 FPC LEDs on the Craft Interface” on page 18
.
Related
Documentation
• MX960 FPC Terminology
•
Replacing an MX960 FPC on page 361
•
Maintaining MX960 FPCs on page 455
•
Troubleshooting the MX960 FPCs on page 492
FPCs Supported by MX240, MX480, and MX960 Routers
An FPC occupies two slots when installed in an MX240, MX480, or MX960 router. The maximum number of supported FPCs varies per router:
• MX960 router—6 FPCs
• MX480 router—3 FPCs
• MX240 router—1 FPC
lists FPCs supported by MX Series routers.
Table 41: FPCs Supported by MX Series Routers
FPC Type FPC Name FPC Model Number
Maximum
Number of PICs
Supported
Maximum
Throughput per FPC
(Full-duplex)
First Junos OS
Release
3
2
FPC3
FPC2
MX-FPC3
MX-FPC2
2
2
20 Gbps
10 Gbps
9.4
9.5
Related
Documentation
• MX Series FPC and PIC Overview
Copyright © 2017, Juniper Networks, Inc.
65
MX960 3D Universal Edge Router Hardware Guide
•
PICs Supported by MX240, MX480, and MX960 Routers on page 68
• High Availability Features
MX960 PIC Description
PICs provide the physical connection to various network media types, receiving incoming packets from the network and transmitting outgoing packets to the network. During this process, each PIC performs framing and line-speed signaling for its media type. Before transmitting outgoing data packets, the PICs encapsulate the packets received from the
FPCs. Each PIC is equipped with an ASIC that performs control functions specific to the media type of that PIC.
PICs are hot-removable and hot-insertable. Up to two PICs can be installed in the slots in each FPC. Up to six FPCs can be installed in an MX960 router. PICs used in an FPC2 have captive screws at their upper and lower corners. PICs used in a Type 3 FPC have an upper ejector handle and a lower captive screw.
Related
Documentation
•
PICs Supported by MX240, MX480, and MX960 Routers on page 68
•
•
Replacing an MX960 PIC on page 382
•
Maintaining MX960 PICs on page 466
•
Troubleshooting the MX960 PICs on page 494
•
MX960 PIC Serial Number Label on page 516
MX960 PIC LEDs
Each PIC has LEDs located on the faceplate. For more information about LEDs on the
PIC faceplate, see the “LEDs” section for each PIC in the MX Series Interface Module
Reference .
Related
Documentation
•
PICs Supported by MX240, MX480, and MX960 Routers on page 68
•
MX960 PIC Description on page 66
•
Replacing an MX960 PIC on page 382
•
Maintaining MX960 PICs on page 466
MX960 PIC Port and Interface Numbering
Each port on a PIC corresponds to a unique interface name in the CLI.
In the syntax of an interface name, a hyphen ( ) separates the media type from the FPC slot number (represented as an FPC in the CLI). The FPC slot number corresponds to the first number in the interface. The second number in the interface corresponds to the PIC number. The last number in the interface matches the port number on the PIC. Slashes
( / ) separate the FPC number from the PIC number and port number:
66 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions type fpc / pic / port
• type —Media type, which identifies the network device. For example:
• ge—Gigabit Ethernet interface
• so—SONET/SDH interface
• xe—10-Gigabit Ethernet interface
For a complete list of media types, see Interface Naming Overview .
• fpc —Lowest slot number in which the FPC is installed. On the MX960 router, the FPCs occupy two slots and are represented in the CLI as FPC 0 through FPC 10 .
• pic —PIC number, 0 or 1 depending on the FPC slot.
For more information on specific PICs, see
“PICs Supported by MX240, MX480, and
in the MX Series Interface Module Reference .
• port —Port number.
The MX960 supports up to six FPCs that install vertically and are numbered from left to right. Each FPC accepts up to two PICs.
shows a Channelized OC12/STM4 Enhanced IQ (IQE) PIC with SFP installed in PIC slot 0 of an FPC installed in slot 3 and slot 4 .
Figure 25: MX960 PIC Interface Port Mapping
0 1 2 3
0 1 2 3
4 5 0 1 2 6 7 8 9 10 11
The show chassis hardware command output displays a Channelized OC12/STM4
Enhanced IQ (IQE) PIC ( 4x CHOC12 IQE SONET ) installed in an MX FPC Type 2 .
user@host> show chassis hardware
...
FPC 3 REV 01 710-024386 JW9571 MX FPC Type 2
CPU REV 03 710-022351 KE2986 DPC PMB
Copyright © 2017, Juniper Networks, Inc.
67
MX960 3D Universal Edge Router Hardware Guide
PIC 0 REV 00 750-022630 DS1284 4x CHOC12 IQE SONET
Xcvr 0 REV 01 740-011782 PB821SG SFP-SX
Xcvr 1 REV 01 740-011782 PB829Q6 SFP-SX
Xcvr 2 REV 01 740-011613 P9F15NQ SFP-SX
Xcvr 3 REV 01 740-011782 P7N036X SFP-SX...
The show interfaces terse command output displays the channelized SONET OC12 interfaces ( coc12 ), that correspond to the four ports located on the PIC.
user@host> show interfaces terse coc12*
Interface Admin Link Proto Local Remote coc12-3/0/0 up up coc12-3/0/1 up up coc12-3/0/2 up up coc12-3/0/3 up up
Related
Documentation
•
MX960 Router Hardware and CLI Terminology Mapping on page 12
PICs Supported by MX240, MX480, and MX960 Routers
lists the PICs supported by MX240, MX480, and MX960 routers.
Table 42: PICs Supported by MX240, MX480, and MX960 Routers
PIC Name PIC Model Number Ports Type First Junos OS Release
Channelized IQ PICs
Channelized OC12/STM4 Enhanced
IQ (IQE) PIC with SFP
PB-4CHOC12-STM4-IQE-SFP
Channelized OC48/STM16 Enhanced
IQ (IQE) PIC with SFP
PB-1CHOC48-STM16-IQE
4
1
2
2
9.5
9.5
SONET/SDH PICs
SONET/SDH OC3/STM1 (Multi-Rate)
PIC with SFP
PB-4OC3-1OC12-SON2-SFP
SONET/SDH OC12/STM4
(Multi-Rate) PIC with SFP
PB-4OC3-4OC12-SON-SFP
SONET/SDH OC48/STM16 Enhanced
IQ (IQE) PIC with SFP
PC-4OC48-STM16-IQE-SFP
SONET/SDH OC48/STM16
(Multi-Rate) PIC with SFP
PB-1OC48-SON-B-SFP
SONET/SDH OC48/STM16 PIC with
SFP
PC-4OC48-SON-SFP
SONET/SDH OC192c/STM64 PIC PC-1OC192-SON-VSR
4
4
4
1
4
1
2
2
3
2
3
3
9.5
9.5
10.4R2
9.5
9.4
9.4
68 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 42: PICs Supported by MX240, MX480, and MX960 Routers
(continued)
PIC Name PIC Model Number Ports Type First Junos OS Release
SONET/SDH OC192c/STM64 PIC with
XFP
PC-1OC192-SON-XFP 1 3 9.4
Related
Documentation
• MX Series FPC and PIC Overview
•
FPCs Supported by MX240, MX480, and MX960 Routers on page 65
• High Availability Features
Interface Modules—MPCs and MICs
•
MX960 Application Services Modular Line Card Description on page 69
•
MX960 Application Services Modular Storage Card Description on page 72
•
MX960 Application Services Modular Processing Card Description on page 73
•
•
•
MIC/MPC Compatibility on page 75
•
MX960 Modular Interface Card Description on page 82
•
MX960 Modular Interface Card (MIC) LEDs on page 82
•
MICs Supported by MX Series Routers on page 82
•
MX960 MIC Port and Interface Numbering on page 86
•
MX960 Modular Port Concentrator Description on page 89
•
MX960 Modular Port Concentrator LEDs on page 92
•
MPCs Supported by MX Series Routers on page 92
MX960 Application Services Modular Line Card Description
The Application Services Modular Line Card (AS MLC) is an X86-based card for MX960,
MX480, and MX240 routers to deliver integrated application service solutions. The first application that network operators can take advantage of is the Junos Content Encore system, a high-throughput, solid state storage platform for media rich content delivery.
Additionally, the AS MLC can serve as the platform for Juniper Networks JunosV App
Engine, powering a host of network applications directly embedded into your MX Series
3D Universal Edge Routers.
The AS MLC is modular and decouples CPU and storage in individual field-upgradeable units. The AS MLCs are designed to enable application throughput up to 50 Gbps and a storage capacity of 400 gigabytes (GB) of NAND Flash.
Copyright © 2017, Juniper Networks, Inc.
69
MX960 3D Universal Edge Router Hardware Guide
Figure 26: Application Services Modular Line Card (AS MLC)
70
MX960 AS MLC Function
The AS MLC provides modular processing and modular storage. Installed on the AS MLC, the Junos Content Encore system operates as a caching application, in either HTTP reverse proxy mode or HTTP transparent proxy mode, to manage client requests for content and the distribution of the content to clients from origin servers. In the future, the AS MLC will run other Juniper Networks router services and applications, and serve as a virtualized platform for third-party applications. The AS MLC provides Ethernet switching and high-speed fabric interface to MX routers. Graceful Routing Engine switchover is also supported on the AS MLC.
Integrated with application forwarding on MX Series routers, the AS MLC provides increased service flexibility with reduced power and space requirements for the network infrastructure.
The AS MLC Modular Carrier Card (AS MCC), the carrier card of the AS MLC, fits vertically in the front of the MX960 router (see
Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Figure 27: AS MLC Installed in the MX960 Router Chassis
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK
FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELLOWALARM
REDALARM
OK
FAIL
NC C NO
NC
OK FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
AS MLC Components
Each AS MLC consists of the following components:
• AS MLC Modular Carrier Card (AS MCC), which fits vertically in front of the MX960 router, includes two slots for the Application Services Modular Storage Card (AS MSC) and Application Services Modular Processing Card (AS MXC)
• AS MXC with 64 GB RAM for processing
• AS MSC with 400 GB NAND Flash capacity for modular storage
NOTE: The AS MCC, AS MXC, and AS MSC are hot-removable and hot-insertable.
• Switch fabric interfaces to the chassis
• XM ASIC chip, which owns and manages the packet data memory built from external
DDR3 memory chips, the fabric queuing system, a portion of the WAN queuing system, and the host queuing system
Copyright © 2017, Juniper Networks, Inc.
71
MX960 3D Universal Edge Router Hardware Guide
• LU ASIC chip, which performs all functions relating to header processing including input processing, route lookup, classification, filtering, policing, accounting, encapsulation, and statistics
• Midplane connectors and power circuitry
• Processor Mezzanine Board (PMB), which that contains the host processor and supporting peripherals
• LED on the AS MCC, which displays the status of the AS MLC
MX960 SCB, Power Supply, and Cooling System Requirements for AS MLC
Each MX960 router requires specific SCB, power supply, and cooling system models to run the AS MLC.
• SCB—Enhanced MX Switch Control Board (SCBE-MX). See
“MX960 SCBE Description” on page 110
for details.
• Power supply:
• 4100W AC power supply—Model PWR-MX960-AC
• 4100W DC power supply—Model PWR-MX960-DC
• Power requirement for AS MLC:
• AS MCC—191W
• AS MXC—259W
• AS MSC—50W
• Cooling system—Required fan and fan tray models:
• Fans:
• For AC power supply: PWR-FAN-MX960-AC-HC-U
• For DC power supply: PWR-FAN-MX960-DC-HC-U
• Fan tray—FFANTRAY-MX960-HC
Related
Documentation
•
Replacing an MX960 AS MLC on page 313
•
Replacing an MX960 AS MSC on page 318
•
Replacing an MX960 AS MXC on page 320
MX960 Application Services Modular Storage Card Description
Application Services Modular Storage Card (AS MSC) is a NAND Flash-based card that is inserted into the upper slot of the Application Services Modular Line Card (AS MLC).
The AS MSC (see
Figure 28 on page 73 ) serves as the second tier caching storage for
platforms such as the Junos Content Encore system. This card is equivalent to a PIC or
72 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions a Modular Interface Card (MIC) and provides a maximum of 3.6 Gbps read and 2 Gbps of write memory.
The AS MSC has the following features:
• 400 GB NAND Flash memory
• Up to 10 years of write memory
• Multilevel cell (MLC) NAND memory support
• Best-in-class NAND controller for maximum performance and reliability
AS MSCs are hot-removable and hot-insertable. One AS MSC can be installed in the top slot of each AS MLC. Each AS MSC has these components:
• SATA-3 controller—An eight-ports, 6 Gbps SAS/SATA controller.
• NAND Flash controller— NAND Flash and NAND Flash controller are used in an AS
MSC.
• Control plane—Inter-integrated circuit control plane that allows Peripheral Component
Interconnect Express (PCIe) control.
• LEDs—Two LEDs display the status of the AS MSC and storage.
• Online/offline button—To power on or power off the AS MSC.
Figure 28: Application Services Modular Storage Card
Related
Documentation
•
•
Replacing an MX960 AS MSC on page 318
MX960 Application Services Modular Processing Card Description
The Application Services Modular Processing Card (AS MXC) is a pluggable X86-based card that can be inserted into the lower slot of the Application Services Modular Line
Card (AS MLC). The AS MXC serves as the processing card for the Junos Content Encore system and contains the two X86, Intel 8-core processors with interface ability greater than 80 Gbps. The AS MXC (see
) is equivalent to a PIC or MIC
(Modular Interface Card).
Copyright © 2017, Juniper Networks, Inc.
73
MX960 3D Universal Edge Router Hardware Guide
AS MXCs are hot-removable and hot-insertable. One MXC can be installed in the lower slot of each AS MLC. Each MXC has these components:
• Two 8-core Intel processors—Contains eight execution cores with Ring Interconnect architecture. Each core supports two threads, up to 16 threads per socket.
• 64 GB DRAM—On DIMM sockets.
• LEDs—Two LEDs on the faceplate display the CPU and application status.
Figure 29: Application Services Modular Processing Card (AS MXC)
Related
Documentation
•
•
Replacing an MX960 AS MXC on page 320
MX960 AS MSC LEDs
Two LEDs ( CPU and AP ) indicate the status of the AS MSC and are located on the AS
MSC.
describes the functions of the AS MSC LEDs.
Table 43: AS MSC LEDs
Label Color State Description
CPU Green
Red
–
On steadily AS MSC operates normally.
On steadily AS MSC has an error or has failed.
Off AS MSC is offline.
AP Green
Red
–
On steadily AS MSC storage operation is normal.
On steadily AS MSC storage operation has an error.
Off AS MSC storage operation is not activated.
74 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Related
Documentation
•
MX960 Application Services Modular Storage Card Description on page 72
•
Replacing an MX960 AS MSC on page 318
MX960 AS MXC LEDs
Two LEDs ( CPU and AP ) indicate the status of the AS MXC and are located on the AS
MXC.
describes the functions of the AS MXC LEDs.
Table 44: AS MXC LEDs
Label Color State Description
CPU
AP
Green
Red
–
Green
Red
On steadily AS MXC operates normally.
On steadily AS MXC has an error or has failed.
Off AS MXC is offline.
On steadily AS MXC applications operation is normal.
On steadily AS MXC applications operation has an error.
– Off AS MXC applications are not activated.
Related
Documentation
•
MX960 Application Services Modular Processing Card Description on page 73
•
Replacing an MX960 AS MXC on page 320
MIC/MPC Compatibility
,
,
Table 49 on page 81 , and Table 50 on page 81
provide a compatibility matrix for the
MICs currently supported by MPC1, MPC2, MPC3, MPC6, MPC8, and MPC9 on MX240,
MX480, MX960, MX2010, and MX2020 routers. The table lists the first Junos OS release in which the MPC supports the MIC. For example, Junos OS Release 10.2 is the first release in which the MX-MPC1-3D supports the Gigabit Ethernet MIC with SFP. An en dash indicates that the MIC is not supported.
Table 45: MIC/MPC1 Compatibility
MIC Name MPC1 MPC1E MPC1 Q MPC1E Q
MIC-3D-8OC3-2OC12-ATM
( ATM MIC with SFP )
— — 12.1
12.1R4
MIC-3D-20GE-SFP
( Gigabit Ethernet MIC with SFP )
10.2
11.2R4
10.2
11.2R4
Copyright © 2017, Juniper Networks, Inc.
75
MX960 3D Universal Edge Router Hardware Guide
Table 45: MIC/MPC1 Compatibility
(continued)
MIC Name MPC1
MIC-3D-20GE-SFP-E
( Gigabit Ethernet MIC with SFP (E) )
13.2R2
MPC1E
13.2R2
MPC1 Q
13.2R2
MIC-3D-2XGE-XFP
( 10-Gigabit Ethernet MICs with XFP )
MIC-3D-4XGE-XFP
( 10-Gigabit Ethernet MICs with XFP )
MIC-3D-40GE-TX
( Tri-Rate MIC )
10.2
—
10.2
11.2R4
—
11.2R4
10.2
—
10.2
MIC-3D-4OC3OC12-1OC48, MIC-3D-8OC3OC12-4OC48 11.2
( SONET/SDH OC3/STM1 (Multi-Rate) MICs with SFP )
MIC-3D-4COC3-1COC12-CE
( Channelized OC3/STM1 (Multi-Rate) Circuit Emulation
MIC with SFP )
—
11.2R4
—
11.2
12.2
MIC-3D-1OC192-XFP
( SONET/SDH OC192/STM64 MIC with XFP )
12.2
MIC-3D-4CHOC3-2CHOC12, MIC-3D-8CHOC3-4CHOC12 —
MIC-4COC3-2COC12-G, MIC-8COC3-4COC12-G
( Channelized SONET/SDH OC3/STM1 (Multi-Rate) MICs with SFP )
12.2
—
12.2
11.4
MIC-3D-16CHE1-T1-CE
( Channelized E1/T1 Circuit Emulation MIC )
MIC-3D-8DS3-E3, MIC-3D-8CHDS3-E3-B
( DS3/E3 MIC )
NOTE: You cannot run Channelized DS3
(MIC-3D-8CHDS3-E3) on non-Q MPCs. Channelized DS3 is supported only on Q and EQ-based MPCs.
11.4
MS-MIC-16G
( Multiservices MIC )
13.2
13.2
13.2
NOTE: Support for
Non-Channelized
MIC only.
NOTE: Support for
Non-Channelized
MIC only.
12.3
11.4
11.4
13.2
13.2
MPC1E Q
13.2R2
11.2R4
—
11.2R4
11.2R4
12.2
12.2
11.4
12.3
11.4
13.2
76 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 46: MIC/MPC2 Compatibility
MIC Name MPC2
MIC-3D-8OC3-2OC12-ATM
( ATM MIC with SFP )
—
MPC2E
—
MIC-3D-20GE-SFP
( Gigabit Ethernet MIC with
SFP )
10.1
MIC-3D-20GE-SFP-E
( Gigabit Ethernet MIC with
SFP (E) )
13.2R2
MIC-3D-2XGE-XFP
( 10-Gigabit Ethernet MIC with
XFP )
10.2
MIC-3D-4XGE-XFP
( 10-Gigabit Ethernet MICs with XFP )
10.1
MIC-3D-40GE-TX
( Tri-Rate MIC )
10.2
MIC-3D-4OC3OC12-1OC48,
MIC-3D-8OC3OC12-4OC48
( SONET/SDH OC3/STM1
(Multi-Rate) MICs with SFP )
11.4
11.2R4
13.2R2
11.2R4
11.2R4
11.2R4
11.4
MPC2E
NG
14.1R4,
14.2R3
with Junos
Continuity
12.1
15.1
14.1R4,
14.2R3
with Junos
Continuity
10.1
15.1
12.1R4
11.2R4
12.1
10.1
12.1R4
11.2R4
14.1R4,
14.2R3
with Junos
Continuity
13.2R2
15.1
13.2R2
14.1R4,
14.2R3
with Junos
Continuity
10.2
15.1
11.2R4
13.2R2
13.2R2
10.2
11.2R4
11.2R4
10.1
11.2R4
14.1R4,
14.2R3
with Junos
Continuity
10.1
15.1
14.1R4,
14.2R3
with Junos
Continuity
10.2
15.1
14.1R4,
14.2R3
with Junos
Continuity
11.4
15.1
11.2R4
11.4
10.2
11.4
11.2R4
11.4
MPC2
Q
MPC2E
Q
MPC2
EQ
MPC2E
EQ
MPC2E
P
MPC2E
NG Q
—
12.2
13.2R2
12.2
14.1R4,
14.2R3
with Junos
Continuity
15.1
14.1R4,
14.2R3
with Junos
Continuity
15.1
12.2
14.1R4,
14.2R3
with Junos
Continuity
15.1
14.1R4,
14.2R3
with Junos
Continuity
15.1
12.2
-
14.1R4,
14.2R3
with Junos
Continuity
15.1
14.1R4,
14.2R3
with Junos
Continuity
15.1
14.1R4,
14.2R3
with Junos
Continuity
15.1
Copyright © 2017, Juniper Networks, Inc.
77
MX960 3D Universal Edge Router Hardware Guide
Table 46: MIC/MPC2 Compatibility
(continued)
MIC Name MPC2
MIC-3D-4COC3-1COC12-CE
( Channelized OC3/STM1
(Multi-Rate) Circuit
Emulation MIC with SFP )
—
MPC2E
—
MPC2E
NG
—
MIC-3D-1OC192-XFP
( SONET/SDH OC192/STM64
MIC with XFP )
12.2
MIC-3D-4CHOC3-2CHOC12,
MIC-3D-8CHOC3-4CHOC12
—
MIC-4COC3-2COC12-G,
MIC-8COC3-4COC12-G
( Channelized SONET/SDH
OC3/STM1 (Multi-Rate) MICs with SFP )
12.2
—
14.1R4,
14.2R3
with Junos
Continuity
12.2
15.1
15.1 with flexible queuing option
11.4
MIC-3D-16CHE1-T1-CE
( Channelized E1/T1 Circuit
Emulation MIC )
MIC-3D-8DS3-E3,
MIC-3D-8CHDS3-E3-B
( DS3/E3 MIC )
NOTE: You cannot run
Channelized DS3
(MIC-3D-8CHDS3-E3) on non-Q MPCs. Channelized
DS3 is supported only on Q and EQ-based MPCs.
11.4
13.2
13.2
NOTE: Support for
Non-Channelized
MIC only.
NOTE: Support for
Non-Channelized
MIC only.
15.1 with flexible queuing option
11.4
12.3
14.1R4,
14.2R3
with Junos
Continuity
11.4
15.1
MS-MIC-16G
( Multiservices MIC )
NOTE: Only one
MS-MIC-16G can be installed into any MPC.
13.2
13.2
14.1R4,
14.2R3
with Junos
Continuity
13.2
15.1
MPC2
Q
MPC2E
Q
MPC2
EQ
MPC2E
EQ
MPC2E
P
MPC2E
NG Q
12.2
12.2
12.2
12.2
12.2
12.2
11.4
12.2
11.4
12.2
11.4
12.2
—
14.1R4,
14.2R3
with Junos
Continuity
15.1
14.1R4,
14.2R3
with Junos
Continuity
15.1
15.1
14.1R4,
14.2R3
with Junos
Continuity
12.3
11.4
13.2
12.3
11.4
13.2
12.3
11.4
13.2
—
12.2
13.2
14.1R4,
14.2R3
with Junos
Continuity
15.1
14.1R4,
14.2R3
with Junos
Continuity
15.1
14.1R4,
14.2R3
with Junos
Continuity
15.1
78 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 47: MIC/MPC3 Compatibility
MIC Name MPC3E
MIC-3D-8OC3-2OC12-ATM
( ATM MIC with SFP )
—
MIC-3D-20GE-SFP
( Gigabit Ethernet MIC with
SFP )
12.1
MIC-3D-20GE-SFP-E
( Gigabit Ethernet MIC with SFP
(E) )
13.2R2
MIC3-3D-1X100GE-CFP
( 100-Gigabit Ethernet MIC with CFP )
12.1
MIC-3D-2XGE-XFP
( 10-Gigabit Ethernet MICs with
XFP )
12.2
MIC-3D-4XGE-XFP
( 10-Gigabit Ethernet MICs with
XFP )
—
MIC3-3D-10XGE-SFPP
( 10-Gigabit Ethernet MIC with
SFP+ (10 Ports) )
12.3
MIC3-3D-2X40GE-QSFPP
( 40-Gigabit Ethernet MIC with
QSFP+ )
12.2
12.2
MIC3-3D-1X100GE-CXP
( 100-Gigabit Ethernet MIC with CXP )
MIC3-100G-DWDM
( 100-Gigabit DWDM OTN MIC with CFP2-ACO )
15.1F5
15.1F6
17.1R1
MPC3E NG
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2 R3 and Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
15.1F5
15.1F6
17.1R1
MPC3E NG Q
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
15.1F5
15.1F6
17.1R1
Copyright © 2017, Juniper Networks, Inc.
79
MX960 3D Universal Edge Router Hardware Guide
Table 47: MIC/MPC3 Compatibility
(continued)
MIC Name MPC3E MPC3E NG
MIC-3D-4OC3OC12-1OC48
MIC-3D-8OC3OC12-4OC48
( SONET/SDH OC3/STM1
(Multi-Rate) MICs with SFP )
13.3
MIC-3D-1OC192-XFP
( SONET/SDH OC192/STM64
MIC with XFP )
13.3
MIC-3D-4COC3-1COC12-CE
( Channelized OC3/STM1
(Multi-Rate) Circuit Emulation
MIC with SFP )
—
MS-MIC-16G
( Multiservices MIC )
NOTE: On MPC3E, the installation of the
Multiservices MIC
(MS-MIC-16G) with
MIC3-3D-2X40GE-QSFPP,
MIC3-3D-10XGE-SFPP, or
MIC3-3D-1X100GE-CFP does not meet the NEBS criteria.
NOTE: Only one MS-MIC-16G can be installed into any MPC.
13.2R2
MIC-3D-40GE-TX
Tri-Rate MIC
—
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
—
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
MIC-3D-4OC3OC12-1OC48,
MIC-3D-8OC3OC12-4OC48
SONET/SDH OC3/STM1
(Multi-Rate) MICs with SFP
12.1
MIC-3D-4CHOC3-2CHOC12,
MIC-3D-8CHOC3-4CHOC12
MIC-4COC3-2COC12-G,
MIC-8COC3-4COC12-G
Channelized SONET/SDH
OC3/STM1 (Multi-Rate) MICs with SFP
12.1
15.1 with flexible queuing option
MPC3E NG Q
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
80 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 47: MIC/MPC3 Compatibility
(continued)
MIC Name MPC3E MPC3E NG
MIC-3D-8DS3-E3,
MIC-3D-8CHDS3-E3-B
DS3/E3 MIC
NOTE: You cannot run
Channelized DS3
(MIC-3D-8CHDS3-E3) on non-Q MPCs. Channelized
DS3 is supported only on Q and EQ-based MPCs.
12.1
14.1R4, 14.2R3 with Junos
Continuity
15.1
Table 48: MIC/MPC6 Compatibility
MIC Name
MIC6-10G
10-Gigabit Ethernet MIC with SFP+ (24 Ports)
MIC6-10G-OTN
10-Gigabit Ethernet OTN MIC with SFP+ (24 Ports)
MIC6-100G-CXP
100-Gigabit Ethernet MIC with CXP (4 Ports)
MIC6-100G-CFP2
100-Gigabit Ethernet MIC with CFP2
Table 49: MIC/MPC8 Compatibility
MIC Name
MIC-MRATE
MIC MRATE
Table 50: MIC/MPC9 Compatibility
MIC Name
MIC-MRATE
MIC MRATE
MPC8E
•
•
15.1F5 with Junos Continuity
16.1R1 and later
MPC9E
•
•
15.1F5 with Junos Continuity
16.1R1 and later
MPC3E NG Q
14.1R4, 14.2R3 with Junos
Continuity
15.1
MPC6E
13.3R2
13.3R3
13.3R2
13.3R3
Related
Documentation
•
MICs Supported by MX Series Routers on page 82
• Junos Continuity Software User Guide (Junos OS Release 14.1R4 and Later Releases)
Copyright © 2017, Juniper Networks, Inc.
81
MX960 3D Universal Edge Router Hardware Guide
MX960 Modular Interface Card Description
Modular Interface Cards (MICs) install into Modular Port Concentrators (MPCs) and provide the physical connections to various network media types. MICs allow different physical interfaces to be supported on a single line card. You can install MICs of different media types on the same MPC as long as the MPC supports those MICs.
MICs receive incoming packets from the network and transmit outgoing packets to the network. During this process, each MIC performs framing and high-speed signaling for its media type. Before transmitting outgoing data packets through the MIC interfaces, the MPCs encapsulate the packets received.
MICs are hot-removable and hot-insertable. You can install up to two MICs in the slots in each MPC.
Related
Documentation
•
MICs Supported by MX Series Routers on page 82
•
MX960 Modular Interface Card (MIC) LEDs on page 82
•
Maintaining MX960 MICs on page 462
•
Troubleshooting the MX960 MICs on page 495
•
Replacing an MX960 MIC on page 367
MX960 Modular Interface Card (MIC) LEDs
Each MIC has LEDs located on the faceplate. For more information about LEDs on the
MIC faceplate, see the “LEDs” section for each MIC in the MX Series Interface Module
Reference .
Related
Documentation
•
MICs Supported by MX Series Routers on page 82
•
MX960 Modular Interface Card Description on page 82
•
Maintaining MX960 MICs on page 462
•
Troubleshooting the MX960 MICs on page 495
•
Replacing an MX960 MIC on page 367
MICs Supported by MX Series Routers
The following tables list the first supported Junos OS release for the MX Series.
•
lists the first supported Junos OS release for MICs on MX240,
MX480, MX960, MX2008, MX2010, and MX2020 routers.
•
lists the first supported Junos OS release for MICs on MX5, MX10,
MX40, MX80, and MX104 routers.
82 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 51: MICs Supported by MX240, MX480, MX960, MX2008, MX2010, and MX2020 Routers
MIC Name MIC Model Number Ports
MX240,
MX480, and
MX960
Routers
MX2008
Routers
MX2010
Routers
MX2020
Routers
ATM
ATM MIC with SFP
DS3/E3
DS3/E3 MIC
MIC-3D-8OC3-2OC12-ATM 8
8
12.1
11.4
15.1F7
15.1F7
12.3
12.3
12.3
12.3
MIC-3D-8DS3-E3,
MIC-3D-8CHDS3-E3-B
Circuit Emulation
Channelized E1/T1 Circuit
Emulation MIC
Gigabit Ethernet
Gigabit Ethernet MIC with SFP
Gigabit Ethernet MIC with SFP
(E)
10-Gigabit Ethernet
10-Gigabit Ethernet MICs with
XFP
10-Gigabit Ethernet MICs with
XFP
10-Gigabit Ethernet MIC with
SFP+ (10 Ports)
10-Gigabit Ethernet MIC with
SFP+ (24 Ports)
10-Gigabit Ethernet OTN MIC with SFP+ (24 Ports)
40-Gigabit Ethernet
40-Gigabit Ethernet MIC with
QSFP+
100-Gigabit Ethernet
100-Gigabit Ethernet MIC with
CFP
MIC-3D-16CHE1-T1-CE
MIC-3D-20GE-SFP
MIC-3D-20GE-SFP-E
MIC-3D-2XGE-XFP
MIC-3D-4XGE-XFP
MIC3-3D-10XGE-SFPP
MIC6-10G
MIC6-10G-OTN
MIC3-3D-2X40GE-QSFPP
MIC3-3D-1X100GE-CFP
16
20
20
2
4
10
24
24
2
1
12.3
10.1
13.3
10.2
10.1
12.3
-
-
12.2
12.1
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
–
12.3
13.3
12.3
12.3
12.3
12.3
13.3
13.3R2
13.3R2
13.3R3
13.3R3
12.3
12.3
–
12.3
12.3
12.3
12.3
12.3
Copyright © 2017, Juniper Networks, Inc.
83
MX960 3D Universal Edge Router Hardware Guide
Table 51: MICs Supported by MX240, MX480, MX960, MX2008, MX2010, and MX2020
Routers
(continued)
MIC Name MIC Model Number Ports
MX240,
MX480, and
MX960
Routers
MX2008
Routers
MX2010
Routers
MX2020
Routers
MIC3-3D-1X100GE-CXP 1 12.2
15.1F7
12.3
12.3
100-Gigabit Ethernet MIC with
CXP
100-Gigabit Ethernet MIC with
CXP (4 Ports)
100-Gigabit Ethernet MIC with
CFP2
MIC6-100G-CXP
MIC6-100G-CFP2
4
2
-
-
15.1F7
15.1F7
13.3R2
13.3R2
13.3R3
13.3R3
100-Gigabit DWDM OTN
100-Gigabit DWDM OTN MIC with CFP2-ACO
MIC3-100G-DWDM 1 15.1F5
15.1F6
17.1R1
15.1F7
15.1F5
15.1F6
17.1R1
15.1F5
15.1F6
17.1R1
Multi-Rate
SONET/SDH OC3/STM1
(Multi-Rate) MICs with SFP
MIC-3D-4OC3OC12-1OC48
SONET/SDH OC3/STM1
(Multi-Rate) MICs with SFP
Channelized SONET/SDH
OC3/STM1 (Multi-Rate) MICs with SFP
Channelized SONET/SDH
OC3/STM1 (Multi-Rate) MICs with SFP
Channelized OC3/STM1
(Multi-Rate) Circuit Emulation
MIC with SFP
MIC-3D-8OC3OC12-4OC48
MIC-3D-4CHOC3-2CHOC12
MIC-3D-8CHOC3-4CHOC12
MIC-3D-4COC3-1COC12-CE
MIC MRATE (12-Port Multi-Rate
MIC with QSFP+)
MIC-MRATE
4
8
4
8
4
12
11.2
11.2
11.4
11.4
12.2
-
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
• 15.1F5
with
Junos
Continuity
• 16.1R1
and later
•
•
15.1F5
with
Junos
Continuity
16.1R1
and later
Tri-Rate
Tri-Rate MIC
Services
MIC-3D-40GE-TX 40 10.2
15.1F7
12.3
12.3
84 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 51: MICs Supported by MX240, MX480, MX960, MX2008, MX2010, and MX2020
Routers
(continued)
MIC Name MIC Model Number Ports
MX240,
MX480, and
MX960
Routers
MX2008
Routers
MX2010
Routers
MX2020
Routers
Multiservices MIC MS-MIC-16G 0 13.2
15.1F7
13.2
13.2
SONET/SDH
SONET/SDH OC192/STM64 MIC with XFP
MIC-3D-1OC192-XFP 1 12.2
15.1F7
12.3
12.3
Table 52: MICs Supported by MX5, MX10, MX40, MX80, and MX104 Routers
MIC Name MIC Model Number Ports MX5 MX10 MX40 MX80
ATM
ATM MIC with SFP
DS3/E3
DS3/E3 MIC
MIC-3D-8OC3-2OC12-ATM 12.1
11.4
12.1
11.4
12.1
11.4
MIC-3D-8DS3-E3,
MIC-3D-8CHDS3-E3-B
8 12.1
8 11.4
Circuit Emulation
Channelized E1/T1 Circuit
Emulation MIC
Channelized E1/T1 Circuit
Emulation MIC (H)
Gigabit Ethernet
Gigabit Ethernet MIC with SFP
Gigabit Ethernet MIC with SFP
(E)
Gigabit Ethernet MIC with SFP
(EH)
10-Gigabit Ethernet
10-Gigabit Ethernet MICs with
XFP
Multi-Rate
SONET/SDH OC3/STM1
(Multi-Rate) MICs with SFP
MIC-3D-16CHE1-T1-CE
MIC-3D-16CHE1-T1-CE-H
MIC-3D-20GE-SFP
MIC-3D-20GE-SFP-E
MIC-3D-20GE-SFP-EH
MIC-3D-2XGE-XFP
MIC-3D-4OC3OC12-1OC48
16 13.2R2
13.2R2
13.2R2
13.2R2
16 –
20 11.2R4
20 13.2R2
11.2R4
11.2R4
10.2
13.2R2
13.2R2
13.2R2
20 –
2 11.2R4
4 11.2R4
–
–
–
–
–
–
11.2R4
11.2R4
10.2
11.2R4
11.2R4
11.2
MX104
13.3
13.3
13.2R2
13.2R2
13.2R2
13.2R2
13.2R2
13.2R2
13.3
Copyright © 2017, Juniper Networks, Inc.
85
MX960 3D Universal Edge Router Hardware Guide
Table 52: MICs Supported by MX5, MX10, MX40, MX80, and MX104 Routers
(continued)
MIC Name MIC Model Number Ports MX5 MX10 MX40 MX80 MX104
MIC-3D-8OC3OC12-4OC48 8 11.2R4
11.2R4
11.2R4
11.2
13.3
SONET/SDH OC3/STM1
(Multi-Rate) MICs with SFP
Channelized SONET/SDH
OC3/STM1 (Multi-Rate) MICs with SFP
Channelized SONET/SDH
OC3/STM1 (Multi-Rate) MICs with SFP
Channelized OC3/STM1
(Multi-Rate) Circuit Emulation
MIC with SFP
MIC-3D-4CHOC3-2CHOC12
MIC-3D-8CHOC3-4CHOC12
MIC-3D-4COC3-1COC12-CE
4 11.4
8 11.4
4 12.2
11.4
11.4
12.2
11.4
11.4
12.2
11.4
11.4
12.2
13.3
13.3
13.2R2
MIC-4COC3-1COC12-CE-H 13.2R2
Channelized OC3/STM1
(Multi-Rate) Circuit Emulation
MIC with SFP (H)
Tri-Rate
Tri-Rate MIC
Services
Multiservices MIC
MIC-3D-40GE-TX
MS-MIC-16G
40 –
0 13.2
Rear slot only.
11.2R4
11.2R4
10.2
13.2
Rear slot only.
13.2
Rear slot only.
13.2R2
13.2
Rear slot only.
Supported on the modular
MX80 and fixed
MX80-48T
13.3R2
SONET/SDH
SONET/SDH OC192/STM64 MIC with XFP
MIC-3D-1OC192-XFP 1 12.2
12.2
12.2
12.2
13.3
Related
Documentation
• MX Series MIC Overview
•
MIC/MPC Compatibility on page 75
MX960 MIC Port and Interface Numbering
Each port on a MIC corresponds to a unique interface name in the CLI.
86 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
NOTE: Fixed configuration MPCs, that is, MPCs with built-in MICs follow the port numbering of DPCs.
In the syntax of an interface name, a hyphen ( ) separates the media type from the MPC number (represented as an FPC in the CLI). The MPC slot number corresponds to the first number in the interface. The second number in the interface corresponds to the logical PIC number. The last number in the interface matches the port number on the
MIC. Slashes ( / ) separate the MPC number from the logical PIC number and port number: type fpc / pic / port
• type —Media type, which identifies the network device. For example:
• ge—Gigabit Ethernet interface
• so—SONET/SDH interface
• xe—10-Gigabit Ethernet interface
For a complete list of media types, see Interface Naming Overview .
• fpc —Slot in which the MPC is installed. On the MX960 router, the MPCs are represented in the CLI as FPC 0 through FPC 11 .
• pic —Logical PIC on the MIC, numbered 0 or 1 when installed in MIC slot 0 and 2 or 3 when installed in MIC slot 1. The number of logical PICs varies depending on the type of MIC. For example, a:
• 20-port Gigabit Ethernet MIC has two logical PICs, numbered 0 and 1 when installed in MIC slot 0, or 2 and 3 when installed in MIC slot 1.
• 4-port 10-Gigabit Ethernet MIC has two logical PICs numbered 0 and 1 when installed in MIC slot 0, or 2 and 3 when installed in MIC slot 1.
• 100-Gigabit Ethernet MIC with CFP has one logical PIC numbered 0 when installed in MIC slot 0 or 2 when installed in MIC slot 1.
For more information on specific MICs, see
“MICs Supported by MX Series Routers” on page 82
in the MX Series Interface Module Reference .
• port —Port number.
NOTE: The MIC number is not included in the interface name.
The MX960 supports up to twelve MPCs that install vertically and are numbered from left to right. Each MPC accepts up to two MICs.
shows an example of a 20-port Gigabit Ethernet MIC with SFP installed in MIC slot 0 of an MPC in slot 3 .
Copyright © 2017, Juniper Networks, Inc.
87
MX960 3D Universal Edge Router Hardware Guide
NOTE: The 20-port Gigabit Ethernet MIC with SFP-E has a different port numbering. See Gigabit Ethernet MIC with SFP (E)
Figure 30: Port Mapping for the 20-Port Gigabit Ethernet MIC with SFP
Installed in the MX960
0 1 2 3
0 1 2 3
4 5 0 1 2 6 7 8 9 10 11
88
The MIC contains two logical PICs, numbered PIC 0 through PIC 1 in the CLI. Each logical
PIC contains 10 ports numbered 0 through 9 .
The show chassis hardware command output displays a 20-port Gigabit Ethernet MIC with SFP — 3D 20x 1GE(LAN) SFP — installed in MIC slot 0 of an MPC ( MPC Type 2 3D
EQ ) in slot 3 . The MPC is shown as FPC 3 and the MIC’s two logical PICs — 10x 1GE(LAN)
SFP — are shown as PIC 0 and PIC 1 .
user@host> show chassis hardware
...
FPC 3 REV 28 750-031090 YH8181 MPC Type 2 3D EQ
CPU REV 06 711-030884 YH9437 MPC PMB 2G
MIC 0 REV 22 750-028392 YD0439 3D 20x 1GE(LAN) SFP
PIC 0 BUILTIN BUILTIN 10x 1GE(LAN) SFP
Xcvr 0 REV 01 740-011613 PCE14D5 SFP-SX
Xcvr 1 REV 01 740-011782 P9C280T SFP-SX
Xcvr 2 REV 01 740-011782 P9C2512 SFP-SX
Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Xcvr 3 REV 02 740-011613 AM0951SFF3Z SFP-SX
Xcvr 4 REV 02 740-011613 AM0951SFF33 SFP-SX
Xcvr 5 REV 02 740-011613 AM0951SFF3Y SFP-SX
Xcvr 6 REV 02 740-011613 AM0951SFF4B SFP-SX
Xcvr 7 REV 01 740-011613 E08H01273 SFP-SX
Xcvr 8 REV 02 740-011613 AM0951SFFWK SFP-SX
PIC 1 BUILTIN BUILTIN 10x 1GE(LAN) SFP
Xcvr 0 REV 01 740-011613 E08H00516 SFP-SX
Xcvr 1 REV 01 740-011613 E08G03648 SFP-SX
Xcvr 2 REV 01 740-011613 E08H00514 SFP-SX
...
The show interfaces terse command output displays the Gigabit Ethernet interfaces that correspond to the 20 ports located on the MIC.
user@host> show interfaces terse ge-3*
Interface Admin Link Proto Local Remote ge-3/0/0 up down ge-3/0/1 up down ge-3/0/2 up down ge-3/0/3 up up ge-3/0/4 up up ge-3/0/5 up up ge-3/0/6 up up ge-3/0/7 up up ge-3/0/8 up up ge-3/0/9 up down ge-3/1/0 up up ge-3/1/1 up up ge-3/1/2 up up ge-3/1/3 up down ge-3/1/4 up down ge-3/1/5 up down ge-3/1/6 up down ge-3/1/7 up down ge-3/1/8 up down ge-3/1/9 up down
Related
Documentation
•
MX960 Router Hardware and CLI Terminology Mapping on page 12
MX960 Modular Port Concentrator Description
Modular Port Concentrators (MPCs) provide packet forwarding services. The MPCs are inserted into a slot in a router. Modular Interface Cards (MICs) provide the physical interfaces and install into the MPCs. You can install up to two MICs of different media types on the same MPC as long as the MPC supports those MICs.
A specialized fixed configuration MPC provides higher port density over MICs and combines packet forwarding and Ethernet interfaces onto a single line card. The fixed configuration
MPC is inserted into a slot in a router and contains no slots for MICs.
MICs receive incoming packets from the network and transmit outgoing packets to the network. During this process, each MIC performs framing and high-speed signaling for its media type. Before transmitting outgoing data packets through the MIC interfaces,
Copyright © 2017, Juniper Networks, Inc.
89
MX960 3D Universal Edge Router Hardware Guide the MPCs encapsulate the packets received. Each MPC is equipped with up to four Junos
Trio chipsets, which perform control functions tailored to the MPC’s media type. The
MPCs interface with the power supplies and Switch Control Boards (SCBs). You must install redundant SCBs to support full line rate.
The MX960 router supports up to 12 MPCs. You must install a high-capacity fan tray to use an MPC. For power requirements, see
“Calculating Power Requirements for MX960
The router has 11 dedicated line-card slots for DPCs, MPCs, or FPCs. MPCs install vertically in the front of the router. The dedicated slots are numbered 0 though 5 , and 7 though 11 , left to right. An additional multifunction slot labeled 2/6 supports either an SCB, a DPC, an FPC, or an MPC. An MPC can be installed in any slot that supports MPCs. You can install any combination of MPC types in the router.
When a slot is not occupied by an MPC or other line card, you must insert a blank DPC panel to fill the empty slot and ensure proper cooling of the system.
MPCs are hot-removable and hot-insertable. When you install an MPC in an operating router, the Routing Engine downloads the MPC software, the MPC runs its diagnostics, and the Packet Forwarding Engines housed on the MPC are enabled. Forwarding on other
MPCs continues uninterrupted during this process.
shows a typical MPC supported on the MX960 router.
shows an MPC installed vertically in the MX960 router. For more information about MPCs, see the MX Series Ethernet Services Routers Line Card Guide .
Figure 31: Typical MPC Supported on the MX960 Router
MPC (empty)
90 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Figure 32: MPC Installed Vertically in the MX960 Router
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK
FAIL OK
FAIL
3
ONLINE
4
ONLINE
0
FAN
1
OK
FAIL
5
ONLINE
RE0
OK
FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK FAIL
NC C NO NC
C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
MPC
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
MPC Components
Each MPC consists of the following components:
• MPC card carrier, which includes two MIC slots (excludes the fixed configuration MPC).
• Fabric interfaces.
• Two Gigabit Ethernet interfaces that allow control information, route information, and statistics to be sent between the Routing Engine and the CPU on the MPCs.
• Two interfaces from the SCBs that enable the MPCs to be powered on and controlled.
• Physical MPC connectors.
• Up to four Junos Trio chipsets, which perform control functions tailored to the MPC’s media type.
• Midplane connectors and power circuitry.
• Processor subsystem, which includes a 1.5-GHz CPU, system controller, and 1 GB of
SDRAM.
Copyright © 2017, Juniper Networks, Inc.
91
MX960 3D Universal Edge Router Hardware Guide
• Online button which takes the MPC online or offline when pressed.
• OK/Fail LED on the MPC faceplate. For more information about LEDs on the MPC faceplate, see the MX Series Interface Module Reference .
Two LEDs, located on the craft interface above the MPC, display the status of the line cards and are labeled OK and FAIL .
Related
Documentation
•
MPCs Supported by MX Series Routers on page 92
•
MX960 Modular Port Concentrator LEDs on page 92
•
MX960 Field-Replaceable Units on page 263
•
Maintaining MX960 MPCs on page 463
•
Troubleshooting the MX960 MPCs on page 496
•
Replacing an MX960 MPC on page 376
MX960 Modular Port Concentrator LEDs
Two LEDs, located on the craft interface above the MPC, display the status of the line cards and are labeled OK and FAIL . For more information about the line card LEDs on the craft interface, see
“MX960 DPC and MPC LEDs on the Craft Interface” on page 18
.
Each MPC also has LEDs located on the faceplate. For more information about LEDs on the MPC faceplate, see the “LEDs” section for each MPC in the MX Series Interface Module
Reference .
Related
Documentation
•
MX960 Modular Port Concentrator Description on page 89
•
Maintaining MX960 MPCs on page 463
•
Troubleshooting the MX960 MPCs on page 496
•
Replacing an MX960 MPC on page 376
MPCs Supported by MX Series Routers
lists the MPCs and their first supported Junos OS release on MX240,
MX480, MX960, MX2008, MX2010, and MX2020 routers.
Table 53: MPCs Supported by MX240, MX480, MX960, MX2008, MX2010, and MX2020 Routers
MPC Name
MPC Model
Number
First Junos OS
Release on
MX240,
MX480, and
MX960 Routers
First Junos OS
Release on
MX2008
Routers
First Junos OS
Release on
MX2010
Routers
First Junos OS
Release on
MX2020
Routers
Fixed Configuration MPCs
16x10GE MPC MPC-3D-
16XGE-SFP
10.0R2
15.1F7
12.3
12.3
92 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 53: MPCs Supported by MX240, MX480, MX960, MX2008, MX2010, and MX2020
Routers
(continued)
MPC Name
MPC Model
Number
First Junos OS
Release on
MX240,
MX480, and
MX960 Routers
First Junos OS
Release on
MX2008
Routers
First Junos OS
Release on
MX2010
Routers
First Junos OS
Release on
MX2020
Routers
Multiservices MPC
32x10GE MPC4E
13.2R4
12.3R2
15.1F7
15.1F7
15.1
12.3R2
15.1
12.3R2
2x100GE + 8x10GE
MPC4E
6x40GE + 24x10GE
MPC5E
MS-MPC
MPC4E-3D-
32XGE-SFPP
MPC4E-3D-
2CGE-8XGE
MPC5E-40G10G
12.3R2
13.3R2
15.1F7
15.1F7
12.3R2
13.3R2
12.3R2
13.3R2
6x40GE + 24x10GE
MPC5EQ
2x100GE + 4x10GE
MPC5E
2x100GE + 4x10GE
MPC5EQ
MPC7E (Multi-Rate)
MPC7E 10G
MPC5EQ-40G10G
MPC5E-100G10G
MPC5EQ-100G10G 13.3R3
MPC7E-MRATE
MPC7E-10G
13.3R2
13.3R3
• 15.1F4 with
Junos
Continuity
• 16.1R1 and later
•
•
15.1F5 with
Junos
Continuity
16.1R1 and later
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
13.3R2
13.3R3
13.3R3
• 15.1F4 with
Junos
Continuity
• 16.1R1 and later
•
•
15.1F5 with
Junos
Continuity
16.1R1 and later
13.3R2
13.3R3
13.3R3
• 15.1F4 with
Junos
Continuity
• 16.1R1 and later
•
•
15.1F5 with
Junos
Continuity
16.1R1 and later
MPCs
MPC1
MPC1E
MPC1 Q
MPC1E Q
MPC2
MX-MPC1-3D
MX-MPC1E-3D
MX-MPC1-3D-Q
MX-MPC1E-3D-Q
MX-MPC2-3D
10.2
11.2R4
10.2
11.2R4
10.1
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
Copyright © 2017, Juniper Networks, Inc.
93
MX960 3D Universal Edge Router Hardware Guide
Table 53: MPCs Supported by MX240, MX480, MX960, MX2008, MX2010, and MX2020
Routers
(continued)
MPC Name
MPC Model
Number
First Junos OS
Release on
MX240,
MX480, and
MX960 Routers
First Junos OS
Release on
MX2008
Routers
First Junos OS
Release on
MX2010
Routers
First Junos OS
Release on
MX2020
Routers
MPC2E
MPC2 Q
MPC2E Q
MPC2 EQ
MX-MPC2E-3D
MX-MPC2-3D-Q
MX-MPC2E-3D-Q
MX-MPC2-3D-EQ
11.2R4
10.1
11.2R4
10.1
15.1F7
15.1F7
15.1F7
15.1F7
12.3
12.3
12.3
12.3
12.3
12.3
12.3
12.3
MPC2E EQ
MPC2E P
MPC2E NG
MPC2E NG Q
MPC3E
MPC3E NG
MPC3E NG Q
MPC6E
MPC8E
MX-MPC2E-3D-EQ 11.2R4
MX-MPC2E-3D-P 12.2
MX-MPC2E-3D-NG 14.1R4, 14.2R3
and Junos
Continuity
15.1
MX-MPC2E-3D-NG-Q 14.1R4, 14.2R3
and Junos
Continuity
15.1
MX-MPC3E-3D 12.1
MX-MPC3E-3D-NG 14.1R4, 14.2R3
and Junos
Continuity
15.1
MX-MPC3E-3D-NG-Q 14.1R4, 14.2R3
and Junos
Continuity
15.1
MX2K-MPC6E
MX2K-MPC8E
–
–
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
15.1F7
12.3
12.3
14.1R4, 14.2R3
and Junos
Continuity
15.1
14.1R4, 14.2R3
and Junos
Continuity
15.1
12.3
14.1R4, 14.2R3
and Junos
Continuity
15.1
14.1R4, 14.2R3
and Junos
Continuity
15.1
13.3R2
• 15.1F5 with
Junos
Continuity
• 16.1R1 and later
12.3
12.3
14.1R4, 14.2R3 and
Junos Continuity
15.1
14.1R4, 14.2R3 and
Junos Continuity
15.1
12.3
14.1R4, 14.2R3 and
Junos Continuity
15.1
14.1R4, 14.2R3 and
Junos Continuity
15.1
13.3R2
• 15.1F5 with
Junos
Continuity
• 16.1R1 and later
94 Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions
Table 53: MPCs Supported by MX240, MX480, MX960, MX2008, MX2010, and MX2020
Routers
(continued)
MPC Name
MPC Model
Number
First Junos OS
Release on
MX240,
MX480, and
MX960 Routers
First Junos OS
Release on
MX2008
Routers
First Junos OS
Release on
MX2010
Routers
First Junos OS
Release on
MX2020
Routers
MPC9E MX2K-MPC9E – 15.1F7
•
•
15.1F5 with
Junos
Continuity
16.1R1 and later
•
•
15.1F5 with
Junos
Continuity
16.1R1 and later
Related
Documentation
• MX Series MPC Overview
•
MIC/MPC Compatibility on page 75
• MX Series MIC Overview
•
MICs Supported by MX Series Routers on page 82
• Junos Continuity Software Overview
• Pathfinder: Hardware Supported by Junos Continuity Software
Copyright © 2017, Juniper Networks, Inc.
95
MX960 3D Universal Edge Router Hardware Guide
96 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 7
Power System Components and
Descriptions
•
MX960 Power System Overview on page 97
•
MX960 AC Power Supply Description on page 98
•
MX960 AC Power Supply LEDs on page 103
•
MX960 DC Power Supply on page 104
•
MX960 DC Power Supply LEDs on page 105
MX960 Power System Overview
The MX960 router uses either AC or DC power supplies. The MX960 router is configurable with three or four normal-capacity AC power supplies, up to four high-capacity DC power supplies, and up to four high-capacity AC power supplies. The power supplies connect to the midplane, which distributes the different output voltages produced by the power supplies to the router components, depending on their voltage requirements.
CAUTION: The router cannot be powered from AC and DC power supplies simultaneously. The first type of power supply detected by the router when initially powered on determines the type of power supply allowed by the router. All installed power supplies of the other type are disabled by the router.
If you install a power supply of the other type while the router is operating, the router disables the power supply and generates an alarm.
All power supplies are hot-removable and hot-insertable. Each power supply is cooled by its own internal cooling system.
Unlike systems with previous MX960 AC supplies, the systems with MX Series high-capacity power supplies are zoned. No current sharing between power supplies is needed with the upgraded system because the redundancy changes from 3+1 per system to 1+1 per zone. For MX960 AC configurations, two zones are present. Two adjacent power supplies need to be installed in the chassis with two feeds attached.
Copyright © 2017, Juniper Networks, Inc.
97
MX960 3D Universal Edge Router Hardware Guide
NOTE: Two AC power cables are required when installing the high-capacity
AC power supplies.
NOTE: Routers configured with DC power supplies are shipped with a blank panel installed over the power distribution modules. Routers configured with
AC power supplies have no blank panel.
NOTE: When upgrading to enhanced power supplies, always upgrade power supplies in adjacent slots.
Related
Documentation
•
Troubleshooting the MX960 Power System on page 498
•
MX960 AC Power Supply Description on page 98
•
MX960 DC Power Supply on page 104
MX960 AC Power Supply Description
The MX960 requires special power supplies that are not interchangeable with the MX240,
MX480, or the MX2000 series routers. Two types of AC power supplies can be used: normal-capacity or high-capacity. Each AC power supply has a corresponding AC appliance inlet located in the MX960 chassis directly above the power supply. Additionally, high-capacity AC power supplies have an AC appliance inlet on the power supply itself.
Each inlet requires a dedicated AC power feed and a dedicated 15 A (250 VAC) circuit breaker. One power cord per feed is required. See
“AC Power Cord Specifications for the
for more details.
Normal-capacity and high-capacity AC power supply configurations are zoned meaning that certain components in the MX960 chassis are powered by specific power supplies.
Normal-capacity AC power supply configurations have one overall zone that provides power to all components in the MX960 chassis. High-capacity AC power supply configurations have two zones that provide power to specific components in the MX960 chassis.
and
illustrate normal-capacity and high-capacity AC power supplies for the MX960.
98 Copyright © 2017, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
Figure 33: MX960 Normal-Capacity AC Power Supply
Figure 34: MX960 with High-Capacity AC Power Supplies Installed
Air exhaust
Input mode switch
AC Power supplies
Power supply ejectors
Grounding points ESD point
The minimum number of power supplies must be present in the router at all times. Refer to
.
Table 54: Minimum Number of Power Supplies Required for the MX960
Router Model Configuration
MX960 High-capacity AC
Minimum Required Number of Power
Supplies
One per zone x two zones = 2 power supplies
Model Number
PWR-MX960-4100-AC
Copyright © 2017, Juniper Networks, Inc.
99
MX960 3D Universal Edge Router Hardware Guide
Table 54: Minimum Number of Power Supplies Required for the MX960
(continued)
MX960 Normal-capacity AC 2 PWR-MX960-AC
•
Normal-Capacity AC Power Supplies on page 100
•
High-Capacity AC Power Supplies on page 100
•
Understanding Input Mode Switch (DIP Switch) Settings on page 101
Normal-Capacity AC Power Supplies
The MX960 can be powered by three normal-capacity AC power supplies (non-redundant configuration) or four normal-capacity AC power supplies (redundant configuration). In a non-redundant configuration, the three AC power supplies share power almost equally within a fully-populated MX960 system. In a redundant configuration there is full power redundancy meaning if one power supply fails or is removed, the remaining power supplies instantly assume the entire electrical load without interruption and provide full power for the maximum configuration for as long as the router is operational.
NOTE: Each normal-capacity power supply must be connected to a dedicated
AC power feed and a dedicated customer site circuit breaker. Juniper recommends that you use a 15 A (250 VAC) minimum, or as required by local code.
High-Capacity AC Power Supplies
The MX960 can also be powered by two high-capacity AC power supplies. The high-capacity power supplies must be installed in adjacent slots in the chassis. They can operate in one-feed mode or two-feed mode. The maximum inrush current for a high-capacity AC power supply is 38A per feed at 264VAC.
In one-feed mode, the power supplies output power at a reduced capacity (1700W). In two-feed mode, the power supplies provide power at full capacity (4100W). To operate the MX960 at full capacity, you must use two-feed mode. High-capacity power supplies require one power cord per feed. Therefore, to operate the MX960 at full capacity, you will need two power cords.
Each high-capacity AC power supply accepts two AC feeds in two unique AC receptacles located on each power supply.
When using the high-capacity AC power supplies in one-feed mode, plug one end of the power cord into the corresponding AC receptacle directly above the power supply in the chassis and the other end into a DC outlet. When using the high-capacity power supply in two-feed mode, you need two power cords. Plug one power cord into the AC receptacle on the chassis and then plug the other end into a DC outlet. Next, plug the second power cord into the AC receptacle on the AC power supply and plug the other end into a DC outlet.
In high-capacity AC power supply configurations, there are two zones that provide power to specific components in the MX system. No current sharing between power supplies
100 Copyright © 2017, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions is needed with the high-capacity system because the redundancy changes from 3+1 per system to 1+1 per zone.
lists the components that receive power for each zone in a high-capacity AC power supply configuration.
Table 55: Zoning for High-Capacity Power Supplies in an MX960
Chassis Power Configuration Zone Power Supply (PEM) Components Receiving Power
MX960 AC high-capacity power supplies
MX960 AC high-capacity power supplies
Zone 0
Zone 1
PEM 0 or 2
PEM 1 or 3
•
•
•
Lower fan tray
DPC/MPC slots 6 through 11
SCB slots 1 through 2
•
•
•
Upper fan tray
DPC/MPC slots 0 through 5
SCB slot 0
Understanding Input Mode Switch (DIP Switch) Settings
Each PSM has two input mode switches (DIP switches) on the faceplate. The DIP switches provide critical information to the power management subsystem to help generate alarms in case of a feed failure or a wrong connection. Each PSM has an LED per feed indicating whether the feed is active and whether the feed is properly connected. You must set the
DIP switch on each high-capacity AC power supply according to how many feeds are connected. When one feed is connected, the system is running in reduced capacity mode.
When two feeds are connected the system is running in full-capacity mode. Use these
DIP switch settings:
• Position-0 indicates one AC feed is present
• Position-1 indicates two AC feeds are present
Refer to
.
Figure 35: Setting the Input Mode Switch (DIP Switch)
1
0
1
0
Copyright © 2017, Juniper Networks, Inc.
101
MX960 3D Universal Edge Router Hardware Guide
Use the show chassis power command to verify that the DIP switch settings on the high-capacity AC power supplies are set to the correct position. Here are examples of the command output:
Example 1: Proper setting of the DIP switch user@host> show chassis power
PEM 0:
State: Online
AC input: OK (2 feed expected, 2 feed connected)
Capacity: 4100 W (maximum 4100 W)
DC output: 855 W (zone 0, 15 A at 57 V, 20% of capacity)
PEM 1:
State: Online
AC input: OK (1 feed expected, 1 feed connected)
Capacity: 1700 W (maximum 4100 W)
DC output: 969 W (zone 1, 17 A at 57 V, 57% of capacity)
In Example 1, PEM 0 is running at full capacity (4100 W) with two AC feeds expected and two AC feeds connected. This indicates that the DIP switch is properly set to Position 1 since two AC feeds are connected. The example also shows that PEM 1 is running at reduced capacity (1700W) with one AC feed expected and one AC feed connected. This indicates that the DIP switch is correctly set to Position 0 since one feed is present.
Example 2 shows the show chassis power command output when the DIP switch is set improperly:
Example 2: Improper Setting of the DIP Switch user@host> show chassis power
PEM 0:
State: Online
AC input: OK (2 feed expected, 2 feed connected)
Capacity: 4100 W (maximum 4100 W)
DC output: 0 W (zone 0, 0 A at 56 V, 0% of capacity)
PEM 1:
State: Present
AC input: Check (2 feed expected, 1 feed connected)
Capacity: 1700 W (maximum 4100 W)
The PEM 0 status indicates the system is Online , the AC Input is OK , is running at full capacity (4100 W) with two AC feeds expected and two AC feeds connected. But notice the status for PEM 1 . The State is Present and the AC input is Check (2 feed expected, 1 feed connected) . This indicates there is a mismatch between the DIP switch setting and the number of feeds connected. Therefore, the power supply is running at reduced capacity
(1700 W). If PEM 1 should be running at full-capacity, verify that there are two feeds connected to the power supplies and the DIP switch is set to position 1.
Related
Documentation
•
MX960 Router Grounding Specifications on page 145
•
Electrical Specifications for the MX960 AC Power Supply on page 151
102 Copyright © 2017, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
•
Calculating Power Requirements for MX960 Routers on page 161
•
Power Requirements for an MX960 Router on page 152
•
AC Power Circuit Breaker Requirements for the MX960 Router on page 165
•
AC Power Cord Specifications for the MX960 Router on page 165
• Site Electrical Wiring Guidelines for MX Series Routers
•
Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power
•
Connecting Power to an AC-Powered MX960 Router with High-Capacity Power Supplies on page 229
•
MX960 Power Supply LEDs on the Craft Interface on page 17
MX960 AC Power Supply LEDs
Each AC power supply faceplate contains three LEDs that indicate the status of the power supply (see
Table 56 on page 103 ). The power supply status is also reflected in
two LEDs on the craft interface In addition, a power supply failure triggers the red alarm
LED on the craft interface.
Table 56: AC Power Supply LEDs
Label Color State Description
AC OK Green
DC OK Green
Off
On
Off
AC power applied to power supply is not within the normal operating range.
AC power applied to power supply is within the normal operating range.
DC power outputs generated by the power supply are not within the normal operating ranges.
PS FAIL Red
On
Off
On
DC power outputs generated by the power supply are within the normal operating ranges.
Power supply is functioning normally.
Power supply is not functioning normally. Check AC OK and DC OK LEDs for more information.
Related
Documentation
•
MX960 Chassis Description on page 9
•
MX960 Power System Overview on page 97
•
MX960 AC Power Supply Description on page 98
Copyright © 2017, Juniper Networks, Inc.
103
MX960 3D Universal Edge Router Hardware Guide
MX960 DC Power Supply
In the DC power configuration, the router contains either two or four DC power supplies
(see
Figure 36 on page 104 ), located at the lower rear of the chassis in slots
PEM0 through PEM3 (left to right). You can upgrade your DC power system from two to four power supplies. The DC power supplies in slots PEM0 and PEM2 provide power to the lower fan tray, DPC slots 6 through 11 , and SCB slots 1 and 2 . The DC power supplies in slots PEM1 and PEM3 provide power to the upper fan tray, DPC slots 0 through 5 , and
SCB slot 0 .
Four power supplies provide full redundancy. If a DC power supply fails, its redundant power supply takes over without interruption.
For existing power supplies, each DC power supply has a single DC input (–48 VDC and return). For high-capacity power supplies, each DC power supply has two DC inputs (–48
VDC and return).
The minimum number of power supplies must be present in the router at all times. See
for the minimum required number of power supplies.
Table 57: Minimum Required Number of DC Power Supplies
Router Model Configuration
MX960 High-capacity DC
Minimum Required Number of Power
Supplies
One per zone x two zones = 2 power supplies
Model Number
PWR-MX960-4100-DC
MX960 Normal-capacity DC 2 PWR-MX960-DC
Figure 36: DC Power Supply
104 Copyright © 2017, Juniper Networks, Inc.
Chapter 7: Power System Components and Descriptions
Figure 37: High-Capacity DC Power Supply
Each high-capacity DC power supply supports two DC feeds. You must set the input mode switch according to the number of DC feeds available for the power entry module(PEM). The input mode switch positions 0 and 1 indicate the following:
• Position 0 —Indicates that only one DC feed is provided.
• Position 1 —Indicates that two DC feeds are provided.
Related
Documentation
•
MX960 DC Power Supply LEDs on page 105
•
MX960 Router Grounding Specifications on page 145
•
Calculating Power Requirements for MX960 Routers on page 161
•
DC Power Circuit Breaker Requirements for the MX960 Router on page 183
•
DC Power Source Cabling for the MX960 Router on page 183
•
DC Power Cable Specifications for the MX960 Router on page 185
• Site Electrical Wiring Guidelines for MX Series Routers
MX960 DC Power Supply LEDs
Each DC power supply faceplate contains three LEDs that indicate the status of the power supply (see
Table 58 on page 106 ). The power supply status is also reflected in
two LEDs on the craft interface. In addition, a power supply failure triggers the red alarm
LED on the craft interface.
Copyright © 2017, Juniper Networks, Inc.
105
MX960 3D Universal Edge Router Hardware Guide
Table 58: DC Power Supply LEDs
Label Color State Description
PWR OK Green Off
BREAKER
ON
Green
On
Off
Power supply is not functioning normally. Check the INPUT OK LED for more information.
Power supply is functioning normally.
DC power supply circuit breaker is turned off.
INPUT OK Green
Yellow
On
Off
On
On
DC power supply circuit breaker is turned on.
DC input to the PEM is not present.
DC input is present and is connected in correct polarity.
DC input is present, but connected in reverse polarity.
Related
Documentation
•
MX960 Power Supply LEDs on the Craft Interface on page 17
•
MX960 Power System Overview on page 97
•
MX960 AC Power Supply Description on page 98
•
MX960 DC Power Supply on page 104
•
Electrical Specifications for the MX960 DC Power Supply on page 169
106 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 8
Switch Fabric Components and
Descriptions
•
MX960 SCB Description on page 107
•
MX960 Switch Control Board LEDs on page 109
•
MX960 SCBE Description on page 110
•
•
SCBE2-MX Description on page 113
•
MX960 SCB Description
The SCB provides the following functions:
• Powers on and powers off DPCs, FPCs, and MPCs
• Controls clocking, system resets, and booting
• Monitors and controls system functions, including fan speed, board power status, PDM status and control, and the craft interface
• Provides interconnections to all the DPCs, FPCs, and MPCs within the chassis through the switch fabrics integrated into the SCB
The Routing Engine installs directly into a slot on the SCB (see
Copyright © 2017, Juniper Networks, Inc.
107
MX960 3D Universal Edge Router Hardware Guide
Figure 38: SCB
SCB Slots
You can install up to three. The SCBs install vertically into the front of the chassis in the slots labeled 0 , 1 , and 2/6 . If any slots are empty, you must install a blank panel.
SCB Redundancy
SCBs installed in slots 0 and 1 provide nonredundant fabric connections. An SCB installed in slot 2/6 , in conjunction with SCBs in slots 0 and 1 , provides redundant fabrics, but the
Routing Engine installed on it receives no power and provides no additional routing functions. If no SCB is installed in slot 2/6 , you must install a blank panel in the slot (see
Table 59: SCB Slot Mapping and Functionality
Functionality Slot 0 Slot 1 Slot 2/6
SCB – Full fabric
Full fabric and redundant Routing Engine SCB
Routing Engine
Redundant fabric and Routing Engine
SCB
Routing Engine
SCB
Routing Engine
SCB
Routing Engine
SCB
Routing Engine
–
SCB
108 Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
SCB Components
Each SCB consists of the following components:
• Chassis management Ethernet switch
• I2C bus logic, used for low-level communication with each component
• Component redundancy circuitry
• Control Board/Routing Engine mastership mechanism
• Gigabit Ethernet switch that is connected to the embedded CPU complex on all components
• Switch fabric—Provides the switching functions for the DPCs, FPCs, and MPCs
• Control field-programmable gate array (FPGA)—Provides the Peripheral Component
Interconnect (PCI) interface to the Routing Engine
• 1000Base-T Ethernet controller—Provides a 1-Gbps Ethernet link between the Routing
Engines
• Ethernet switch—Provides 1-Gbps link speeds between the Routing Engine and the
DPCs, FPCs, and MPCs
• Circuits for chassis management and control
• Power circuits for the Routing Engine and SCB
• LEDs—Provide status
Related
Documentation
•
MX960 Host Subsystem Description on page 27
•
MX960 Routing Engine Description on page 29
•
MX960 Switch Control Board LEDs on page 109
•
Replacing an MX960 SCB on page 409
MX960 Switch Control Board LEDs
Three LEDs on the SCB indicate the status of the SCB. The LEDs, labeled FABRIC ACTIVE ,
FABRIC ONLY , and OK/FAIL , are located directly on the SCB.
describes the functions of the SCB LEDs.
Table 60: SCB-MX LEDs
Label Color State Description
Green On steadily Fabric is in active mode.
FABRIC
ACTIVE
FABRIC
ONLY
Green
–
On steadily SCB-MX operates in fabric-only mode.
Off SCB-MX operates in fabric/control board mode.
Copyright © 2017, Juniper Networks, Inc.
109
MX960 3D Universal Edge Router Hardware Guide
Table 60: SCB-MX LEDs
(continued)
Label Color State Description
OK/FAIL Green
Red
–
On steadily SCB-MX is online.
On steadily SCB-MX has failed.
Off SCB-MX is offline.
Each SCB also has two LEDs on the craft interface that indicate its status. The SCB LEDs, labeled 0 and 1 , are located along the bottom of the craft interface. For more information about the SCB LEDs on the craft interface, see
“MX960 SCB LEDs on the Craft Interface” on page 18
.
Related
Documentation
•
MX960 SCB Description on page 107
•
MX960 Host Subsystem Description on page 27
•
Replacing an MX960 SCB on page 409
MX960 SCBE Description
The MX SCBE serves the carrier Ethernet services router and carrier Ethernet transport markets that require higher-capacity traffic support demanding greater interface density
(slot and capacity scale), as well as improved services. The upgraded SCB is supported on MX960, MX480, and MX240 routers. Some key attributes of the MX SCBE are:
• 160 Gbps/slot bandwidth with redundant fabric support, and improved fabric performance by using the next-generation fabric (XF) chip
• A central clocking module and a centralized clocking architecture that supports clock cleanup and distribution. The Stratum 3 clock module performs clock monitoring, filtering, and holdover in a centralized chassis location
• Full performance with fabric redundancy for higher capacity line cards such as 16x10GE and MPC3
The Routing Engine installs directly into a slot on the MX SCBE (see
110 Copyright © 2017, Juniper Networks, Inc.
Figure 39: MX SCBE
SCBE-MX
Chapter 8: Switch Fabric Components and Descriptions
MX SCBE Slots
You can install up to three MX SCBEs. The MX SCBEs install vertically into the front of the chassis in the slots labeled 0 , 1 , and 2 . If any slots are empty, you must install a blank panel.
MX SCBE Redundancy
If three MX SCBEs are installed, the third MX SCBE functions as the backup.
MX SCBE Components
Each MX SCBE consists of the following components:
• I2C bus logic, used for low-level communication with each component
• Component redundancy circuitry
• Control Board/Routing Engine mastership mechanism
• Gigabit Ethernet switch that is connected to the embedded CPU complex on all components
• External clock interface—Allows BITS or GPS clock source input to the centralized timing circuit, or allows centralized timing to be output to BITS or GPS
Copyright © 2017, Juniper Networks, Inc.
111
MX960 3D Universal Edge Router Hardware Guide
• Switch fabric—Provides the switching functions for the DPCs, FPCs, and MPCs
• Control field-programmable gate array (FPGA)—Provides the Peripheral Component
Interconnect (PCI) interface to the Routing Engine
• 1000Base-T Ethernet controller—Provides a 1-Gbps Ethernet link between the Routing
Engines
• Circuits for chassis management and control
• Power circuits for the Routing Engine and SCBE
• LEDs—Provide status of the SCBE and clocking interface
Related
Documentation
•
MX960 SCB Description on page 107
•
•
Upgrading an MX960 SCB to SCBE on page 413
MX960 SCBE LEDs
The FABRIC ACTIVE , FABRIC ONLY , and OK/FAIL LEDs indicate the status of the MX
SCBE. The BITS , GPS , and UTI LEDs, located next to the EXT CLK port, indicate the status of the respective clocking interface.
describes the functions of the
MX SCBE LEDs.
Table 61: MX SCBE LEDs
Label Color State Description
Green On steadily Fabric is in active mode.
FABRIC
ACTIVE
FABRIC
ONLY
Green On steadily MX SCBE operates in fabric-only mode.
OK/FAIL
–
Green
Red
–
Red
–
Off MX SCBE operates in fabric/control board mode.
On steadily MX SCBE is online.
On steadily MX SCBE has failed.
Off MX SCBE is offline.
On steadily GPS clocking interface has failed.
Off GPS clocking interface is offline.
NOTE: The LEDs BITS , GPS , and UTI are not currently supported.
112 Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
Table 61: MX SCBE LEDs
(continued)
Label Color State Description
BITS Green
GPS
Red
–
Green
On steadily Building-integrated timing supply (BITS) clocking interface is active.
On steadily BITS clocking interface has failed.
Off BITS clocking interface is offline.
On steadily Global positioning system (GPS) clocking interface is active.
UTI
Red
–
Green
Red
–
On steadily GPS clocking interface has failed.
Off GPS clocking interface is offline.
On steadily Universal Timing Interface (UTI) clocking interface is active.
On steadily UTI clocking interface has failed.
Off UTI clocking interface is offline.
Related
Documentation
•
MX960 SCBE Description on page 110
•
MX960 Host Subsystem Description on page 27
•
Upgrading an MX960 SCB to SCBE on page 413
SCBE2-MX Description
The SCBE2-MX features the third-generation fabric on the MX960, MX480, and MX240 routers. It uses the XF2 ASIC fabric chip, providing support for higher interface density
(slot and capacity scale) as well as improved services. The SCBE2-MX was released with
Junos release 13.3R1.
The SCBE2-MX is installed vertically in the MX960 chassis and horizontally in the MX480 and MX240 chassis. The routing engine is installed directly into a slot on the SCBE2-MX
(see
).
Copyright © 2017, Juniper Networks, Inc.
113
MX960 3D Universal Edge Router Hardware Guide
Figure 40: SCBE2-MX
114
Software release
Requirements
SCBE2-MX Features
•
•
Junos OS Release 13.3 R1 and later
Name in CLI: SCBE2
For proper cooling, you must install MX-series high-capacity fan trays in the MX chassis.
Additionally, for the MX960, you must install a high-capacity filter tray.
• Provides improved fabric performance for high-capacity line cards using the third generation fabric XF2 chip.
•
•
Provides bandwidth of up to 340 Gbps per slot with redundant fabric support and 480 Gbps per slot without redundant fabric support.
Provides a central clocking module and a centralized clocking architecture that supports clock cleanup and distribution. The Stratum 3 clock module performs clock monitoring, filtering, and holdover at a centralized chassis location.
•
•
•
•
Supports dynamic multicast replication.
Supports GRES.
Supports MPC line cards. Does not support DPCs.
Allows you to configure the system such that one SCBE2-MX supports a GPS interface, and the other SCBE2-MX supports a BITS interface.
•
•
•
•
Provides support for cross-coupling of clock input. This requires an enhanced midplane:
MX960—CHAS-BP3-MX960-S
MX480—CHAS-BP3-MX480-S
MX240—CHAS-BP3-MX240-S
Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
SCBE2-MX Components • Two 10-Gigabit Ethernet SFP+ ports. SFP+ port 0 can be used to connect an external device as a Router Reflector. SFP+ port 1 is unused.
Control Board and Routing Engine (CB-RE) mastership mechanism.
•
• External clock interface—Allows BITS or GPS clock source input to the centralized timing circuit, or allows centralized timing to be output to BITS or GPS.
Switch fabric—Provides switching functions for MPCs.
•
•
•
•
1000Base-T Ethernet controller—Provides a 1-Gbps Ethernet link between the Routing Engines.
Power circuits for the Routing Engine and the SCBE2-MX.
LEDs—Provide status of the SCBE2-MX and the clocking interface.
SCBE2-MX Slots For the MX960:
•
•
•
You can install up to three SCBE2-MX’s in the MX960 router chassis.
SCBE2-MX’s are installed vertically into the front of the MX960 chassis in the slots labeled 0 ,
1 , and 2 . If any slots are empty, you must install a blank panel.
The two SCBE2-MX’s residing in slot 6 and slot 7 of the MX960 chassis provide both control and switch fabric features, while the third SCBE2-MX residing in slot 8 of the chassis (hybrid slot) will only do fabric functions.
For the MX480 and MX240 routers:
• You can install either one or two SCBE2-MX’s in the MX480 and MX240 router chassis.
SCBE2-MX’s are installed horizontally into the front of the MX480 and MX240 chassis in the slots labeled 0 and 1. If any slots are empty, you must install a blank panel.
SCBE2-MX Fabric
Planes and Redundancy
For the MX960:
• Each SCBE2-MX provides two switch fabric planes for packet forwarding among the MPCs in the MX960.
•
•
•
The MX960 chassis may contain up to three SCBE2-MX's Therefore, six fabric planes are available.
Three SCBE2-MX’s are required for 2 + 1 redundancy.
•
In redundant fabric mode, four fabric planes from the first two SCBE2-MX’s will be in Active mode, and two fabric planes from the third SCBE2-MX will be in Spare mode.
In an increased fabric bandwidth mode, all six fabric planes will be in Active mode.
For the MX240 and MX480 routers:
• Each SCBE2-MX provides four switch fabric planes for packet forwarding among the MPCs in the MX480 and MX240 chassis.
• The MX480 and MX240 routers contain a maximum of two SCBE2-MX’s. Therefore, eight logical planes are available.
Two SCBE2-MX’s are required for 1 + 1 redundancy.
•
• In redundant fabric mode, four fabric planes from the first SCBE2-MX will be in Active mode, and four fabric planes from the second SCBE2-MX will be in Spare mode.
In an increased fabric bandwidth mode, all eight fabric planes will be in Active mode.
•
• Each fabric ASIC is configured in virtual plane mode, where two virtual planes exist on one fabric ASIC.
Weight and Dimensions
•
•
•
•
Weight: 9.6 lb (4.4 kg) (with Routing Engine installed)
Width: 17 in (43.2 cm)
Depth: 22 in (55.9 cm)
Height: 1.25 in (3.2 cm) height.
Copyright © 2017, Juniper Networks, Inc.
115
MX960 3D Universal Edge Router Hardware Guide
Maximum Power
Requirements
LEDs
SCBE2-MX (applies to MX240, MX480, and MX960)
185 W at 55° C
160 W at 40° C
155 W at 25° C
•
•
•
FABRIC ACTIVE , FABRIC ONLY , and OK/FAIL LEDs indicate the status of the SCBE2-MX.
The BITS , GPS , and UTI LEDs, located next to the EXT CLK port, indicate the status of the respective clocking interface.
The LINK LED located next to the two Ethernet ports, indicate the status of the respective SFP+ interface.
For more information about the SCBE2-MX LEDs, see
.
SCBE2 Interoperability with Existing Hardware
SCBE2 Operating Mode MX240/480/960
Mixed Mode Allowed
(DPC+MPC in a chassis)
DPC/MS-DPC
MS-MPC
MPC1/MPC2
MPC3
16x10G MPC
MPC4
Enhanced IP/Enhanced
Ethernet Mode Only
Routing Engines
MPC2-NG/MPC3-NG
MPC5
MPC6
MPC7 (480G)
MPC8 (960 Gbps)/MPC9 (1.6Tbps)
RE-S-1300(EOLed)
RE-S-2000 (EOLed)
RE-S-1800
RE-S-X6-64G
Yes
Yes
No
Yes
No yes yes yes yes
Supported
No
Yes
Yes
Yes
Yes
Yes
Related
Documentation
• MX-Series Switch Control Board (SBC) Overview
•
116 Copyright © 2017, Juniper Networks, Inc.
Chapter 8: Switch Fabric Components and Descriptions
SCBE2-MX LEDs
FABRIC ACTIVE , FABRIC ONLY , and OK/FAIL LEDs indicate the status of the SCBE2-MX.
The BITS , GPS , and UTI LEDs, located next to the EXT CLK port, indicate the status of the respective clocking interface. The LINK LED located next to the two Ethernet ports, indicate the status of the respective SFP+ interface.
describes the functions of the SCBE2-MX LEDs.
Table 62: SCBE2-MX LEDs
Label Color State Description
Green On steadily Fabric is in active mode.
FABRIC
ACTIVE
FABRIC
ONLY
OK/FAIL
Green
–
Green
Red
–
On steadily SCBE2-MX operates in fabric-only mode.
Off SCBE2-MX operates in fabric or control-board mode.
On steadily SCBE2-MX is online.
On steadily SCBE2-MX has failed.
Off SCBE2-MX is offline.
BITS Green
GPS
UTI
LINK
Red
–
Green
Red
–
Green
Red
–
Green
–
On steadily Building-integrated timing supply (BITS) clocking interface is active.
On steadily BITS clocking interface has failed.
Off BITS clocking interface is offline.
On steadily Global positioning system (GPS) clocking interface is active.
On steadily GPS clocking interface has failed.
Off GPS clocking interface is offline.
On steadily Universal Timing Interface (UTI) clocking interface is active.
On steadily UTI clocking interface has failed.
Off UTI clocking interface is offline.
On steadily Port is enabled and link is established.
Off Port is disabled or no link is established.
Copyright © 2017, Juniper Networks, Inc.
117
MX960 3D Universal Edge Router Hardware Guide
Related
Documentation
•
SCBE2-MX Description on page 113
• MX-Series Switch Control Board (SBC) Overview
118 Copyright © 2017, Juniper Networks, Inc.
PART 2
Site Planning, Preparation, and
Specifications
•
Preparation Overview on page 121
•
Transceiver and Cable Specifications on page 133
•
Pinout Specifications on page 145
•
AC Power Requirements, Specifications, and Guidelines on page 151
•
DC Power Requirements, Specifications, and Guidelines on page 169
Copyright © 2017, Juniper Networks, Inc.
119
MX960 3D Universal Edge Router Hardware Guide
120 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 9
Preparation Overview
•
MX960 Router Physical Specifications on page 121
•
MX960 Router Environmental Specifications on page 124
•
MX960 Site Preparation Checklist on page 124
•
MX960 Rack Requirements on page 125
•
Clearance Requirements for Airflow and Hardware Maintenance for the MX960
•
MX960 Cabinet Size and Clearance Requirements on page 130
•
MX960 Cabinet Airflow Requirements on page 130
MX960 Router Physical Specifications
summarizes the physical specifications for the router chassis.
Table 63: Physical Specifications
Description Weight Width Depth Height
Standard chassis dimensions
Standard chassis with midplane, two fan trays, air filter, and standard cable manager: 150 lb
(68.04 kg)
17.37 in. (44.11 cm)
(excluding the mounting flanges or brackets)
Standard chassis with maximum configuration: 350 lb
(158.76 kg)
Standard chassis with components removed: 150 lb
(68.04 kg)
23.0 in. (58.42 cm)
(from front-mounting flange to chassis rear)
27.75 in. (70.49 cm)
Total depth (including standard cable manager)
27.75 in. (70.49 cm)
Copyright © 2017, Juniper Networks, Inc.
121
MX960 3D Universal Edge Router Hardware Guide
Table 63: Physical Specifications
(continued)
Description Weight Width Depth Height
Router with extended cable manager installed
Chassis with midplane, two fan trays, air filter, and extended cable manager: 174 lb
(78.93 kg)
Chassis with extended cable manager and maximum configuration: 374 lb
(169.64 kg)
17.37 in. (44.11 cm)
(excluding the mounting flanges or brackets)
Chassis with components removed: 174 lb
(78.93 kg)
23.0 in. (58.42 cm)
(from front-mounting flange to chassis rear)
36.5 in. (92.7 cm) high
Total depth (including extended cable manager) approximately
29.00 in. (73.7 cm)
Router with high-capacity power supplies installed
Standard chassis with midplane, two fan trays, air filter, and standard cable manager: 195 lb
(88.45 kg)
17.37 in. (44.11 cm)
(excluding the mounting flanges or brackets)
Standard chassis with maximum configuration: 395 lb
(179.17 kg)
Standard chassis with components removed: 195 lb
(88.45 kg)
Router with high-capacity power supplies installed.
Depth with high-capacity AC power supply is
30.65" (77.9 cm); depth with high-capacity DC power supply is
32.85" (83.4 cm).
27.75 in. (70.49 cm)
Craft interface
DPC
8.5 in (21.6 cm)
22 in (55.9 cm)
6.25 in (15.9 cm)
1.25 in (3.2 cm)
FPC
PIC
MPC weight (fixed configuration)
MPC (without MICs)
1.5 lb (0.68 kg)
FPC2: 15 lb (6.8 kg)
FPC3: 14 lb (6.5 kg)
17 in (43.2 cm)
Maximum up to 14.5 lb
(6.6 kg)
17 in (43.2 cm)
Blank panel in DPC slot: 9 lb
17 in (43.2 cm)
2 lb (0.9 kg)
18.35 lb (8.3 kg)
7.75 in (28.3 cm)
17 in (43.2 cm)
14 lb (6.4 kg) 17 in (43.2 cm)
22 in (55.9 cm)
11.125 in (19.7 cm)
22 in (55.9 cm)
22 in (55.9 cm)
2.5 in (6.4 cm)
4.125 in (10.5 cm)
1.25 in (3.2 cm)
1.25 in (3.2 cm)
122 Copyright © 2017, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Table 63: Physical Specifications
(continued)
Description Weight Width
MIC
AC power supply
High-capacity AC power supply
DC power supply
Maximum up to 1.2 lb
(0.54 kg)
6.25 in (15.9 cm)
5 lb (2.3 kg) each
11.9 lb (5.4 kg) each
14.5 in (36.8 cm)
14.5 in (36.8 cm)
3.8 lb (1.7 kg) 14.5 in (36.8 cm)
14.5 in (36.8 cm) High-capacity DC power supply
Air filter
SCB
SCBE
SCBE2
15.8 lb (7.2 kg)
1 lb (0.5 kg)
9.6 lb (4.4 kg) (with
Routing Engine installed)
9.6 lb (4.4 kg) (with
Routing Engine installed)
9.6 lb (4.4 kg) (with
Routing Engine installed)
Routing Engine
Routing Engine
(RE-S-1800)
Routing Engine
(RE-S-X6-64G)
Upper fan tray
Lower fan tray
2.4 lb (1.1 kg)
2.4 lb (1.1 kg)
2.69 lb (1.18 kg)
13 lb (5.9 kg)
13 lb (5.9 kg)
High-capacity fan tray
Standard cable manager
13 lb (5.9 kg)
4.1 lb (1.9 kg
Extended cable manager 39 lb (2.3 kg)
16.7 in (42.4 cm)
17 in (43.2 cm)
17 in (43.2 cm)
17 in (43.2 cm)
11 in (27.9 cm)
11 in (27.9 cm)
10.7 in (27.18 cm)
16.9 in (43 cm)
16.9 in (43 cm)
16.9 in (43 cm)
18.9 in (43 cm)
24.5 in (62.2 cm)
Related
Documentation
•
MX960 Router Overview on page 3
•
MX960 Chassis Description on page 9
Depth
6.8 in (17.3 cm)
Height
1.25 in (3.2 cm)
4 in (10.2 cm)
6.85 in (12.92 cm)
1.75 in (4.4 cm)
1.75 in (4.4 cm)
4 in (10.2 cm)
9.05 in (22.99 cm)
1.75 in (4.4 cm)
1.75 in (4.4 cm)
19.7 in (50 cm)
22 in (55.9 cm)
0.43 in (1.1 cm)
1.25 in (3.2 cm)
22 in (55.9 cm)
22 in (55.9 cm)
1.25 in (3.2 cm)
1.25 in (3.2 cm)
7.75 in (19.7 cm)
7.75 in (19.7 cm)
7.47 in (18.97 cm)
20.6 in (3.6 cm)
20.6 in (52.3 cm)
20.6 in (52.3 cm)
5.5 in (14 cm)
30 in (78 cm)
1.25 in (3.2 cm)
1.25 in (3.2 cm)
1.19 in (3.02 cm)
1.4 in (3.6 cm)
1.4 in (3.6 cm)
1.4 in (3.6 cm)
6.7 in (17 cm)
24.25 in (61.6 cm)
Copyright © 2017, Juniper Networks, Inc.
123
MX960 3D Universal Edge Router Hardware Guide
MX960 Router Environmental Specifications
specifies the environmental specifications required for normal router operation. In addition, the site should be as dust-free as possible.
Table 64: Router Environmental Specifications
Description Value
Altitude
Relative humidity
Temperature
Seismic
No performance degradation to 10,000 ft (4038 m)
Normal operation ensured in relative humidity range of 5% to 90%, noncondensing
Normal operation ensured in temperature range of 32°F (0°C) to
104°F (40°C)
Nonoperating storage temperature in shipping container:
–40°F (–40°C) to 158°F (70°C)
Designed to meet Telcordia Technologies Zone 4 earthquake requirements
Maximum thermal output AC power: 27,007 BTU/hour (7920 W)
DC power: 18,987 BTU/hour (5568 W)
NOTE: Install the router only in restricted areas, such as dedicated equipment rooms and equipment closets, in accordance with Articles 110-16, 110-17, and
110-18 of the National Electrical Code, ANSI/NFPA 70.
Related
Documentation
•
Tools and Parts Required to Maintain the MX960 Router on page 445
• Definition of Safety Warning Levels
MX960 Site Preparation Checklist
The checklist in
summarizes the tasks you must perform when preparing a site for router installation.
Table 65: MX960 Site Preparation Checklist
Item or Task For More Information Performed By Date
Verify that environmental factors such as temperature and humidity do not exceed router tolerances.
124 Copyright © 2017, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Table 65: MX960 Site Preparation Checklist
(continued)
Item or Task For More Information
Select the type of rack or cabinet.
“MX960 Cabinet Size and Clearance
,
“MX960 Rack Requirements” on page 125
Plan rack or cabinet location, including required space clearances.
“MX960 Cabinet Size and Clearance
,
“MX960 Rack Requirements” on page 125 ,
“Clearance Requirements for Airflow and Hardware Maintenance for the
If a rack is used, secure rack to floor and building structure.
“MX960 Rack Requirements” on page 125
Acquire cables and connectors.
Performed By
Locate sites for connection of system grounding.
Measure distance between external power sources and router installation site.
Calculate the optical power budget and optical power margin.
Power Margin for Fiber-Optic Cables” on page 140
Date
Related
Documentation
•
Installing an MX960 Router Overview on page 203
•
Unpacking the MX960 Router on page 189
MX960 Rack Requirements
The router can be installed in many types of racks, including four-post (telco) racks and open-frame racks. An example of an open-frame rack appears in
Copyright © 2017, Juniper Networks, Inc.
125
MX960 3D Universal Edge Router Hardware Guide
Figure 41: Typical Open-Frame Rack
•
Rack Size and Strength on page 126
•
Spacing of Mounting Bracket Holes on page 127
•
Connection to the Building Structure on page 128
Rack Size and Strength
The size, strength, and location of the rack must accommodate the router's weight and external dimensions. The location of the rack must allow for the clearance requirements specified in
“Clearance Requirements for Airflow and Hardware Maintenance for the
The chassis is 17.37 in. (44.11 cm) wide. The router is designed for installation in a standard
19-in. rack, as defined in Cabinets, Racks, Panels, and Associated Equipment (document number EIA-310-D) published by the Electronic Components Industry Association (ECIA)
( http://www.ecianow.org
). The spacing of the holes between the left and right front-mounting flanges and center-mounting brackets is 19 in. (48.3 cm) apart. However, the inner edge of the rack rails must allow sufficient space for the width of the chassis.
With the use of adapters or approved wing devices to narrow the opening between the rails, the router can fit into a 600-mm-wide rack, as defined in the four-part Equipment
126 Copyright © 2017, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Engineering (EE); European telecommunications standard for equipment practice
(document numbers ETS 300 119-1 through 119-4) published by the European
Telecommunications Standards Institute ( http://www.etsi.org
).
The weight, height, and depth of the router depends on the type of cable manager installed.
With the standard cable manager installed, use these guidelines:
• The rack must have sufficient vertical usable space to accomodate the height of the router: 27.75 in. (70.49 cm) high (approximately 16 U.),. You can stack three MX960 routers with the standard cable manager in a rack that has at least 48 U (89.3 in. or
2.24 m).
NOTE: A U is the standard rack unit defined in Cabinets, Racks, Panels, and
Associated Equipment (document number EIA-310-D) published by the
Electronic Components Industry Association (ECIA)
( http://www.ecianow.org
).
• The location of the rack must provide sufficient space to accomodate the depth of the router. The chassis is 23.0 in. (58.42 cm) deep, but The standard cable manager extends the depth to 28.0 in. (71.1 cm).
• The rack must be strong enough to support the weight of the fully configured router, up to 350 lb (158.76 kg). If you stack three fully configured routers, it must be capable of supporting up to 1,050 lb (476.3 kg).
With the extended cable manager installed, use these guidelines:
• The rack must have sufficient vertical usable space to accomodate the additional height of the extended cable manager: 36.5 in. (92.7 cm) high (approximately 21 U).
You can stack two MX960 routers in a rack that has at least 48 U (89.3 in. or 2.24 m).
• The rack must be able to accomodate the additional depth of the extended cable manager. The chassis with the extended cable manager installed is29.00 in. (73.7 cm) deep.
• The rack must be strong enough to support up to 374 lb (169.64 kg). If you stack two fully configured routers, it must be capable of supporting up to 748 lb (339.28 kg).
Spacing of Mounting Bracket Holes
The holes within each set are spaced at 1 U (1.75 in. or 4.5 cm). The router can be mounted in any rack that provides holes spaced at those distances.
The router can be mounted in any rack that provides holes or hole patterns spaced at 1U
(1.75 in.) increments. The mounting brackets and front-mount flanges used to attach the chassis to a rack are designed to fasten to holes spaced at those distances.
Copyright © 2017, Juniper Networks, Inc.
127
MX960 3D Universal Edge Router Hardware Guide
Connection to the Building Structure
Always secure the rack to the structure of the building. If your geographical area is subject to earthquakes, bolt the rack to the floor. For maximum stability, also secure the rack to ceiling brackets.
Related
Documentation
•
Clearance Requirements for Airflow and Hardware Maintenance for the MX960 Router on page 128
•
MX960 Rack-Mounting Hardware on page 14
•
MX960 Cabinet Size and Clearance Requirements on page 130
•
MX960 Cabinet Airflow Requirements on page 130
Clearance Requirements for Airflow and Hardware Maintenance for the MX960 Router
When planning the installation site, you need to allow sufficient clearance around the rack (see
• For the cooling system to function properly, the airflow around the chassis must be unrestricted.
• For service personnel to remove and install hardware components, there must be adequate space at the front and back of the router. At least 24 in. (61 cm) is required both in front of and behind the router. NEBS GR-63 recommends that you allow at least 30 in. (76.2 cm) behind the router.
Airflow must always be from front to back with respect to the rack. The device must not interfere with the cooling of other systems in the rack. Fillers must be used as appropriate in the rack to ensure there is no recirculation of heated exhaust air back to the front of the rack. Care must also be taken around cables to ensure that no leakage of air in situations where recirculation may result.
• Additional clearance is required to accommodate the height and depth of the chassis with the extended cable manager:
• 36.5 in. (92.7 cm) high
• 29.00 in. (73.7 cm) deep approximately
• Additional clearance is also required to accommodate the depth of the MX960 high-capacity power supplies; they extend beyond the chassis as shown in
.
Table 66: Clearance Requirements for High-Capacity Power Supplies
Power Supply Additional depth requirement
MX960 high-capacity AC power supply
MX960 high-capacity DC power supply
2.85” (7.24 cm)
5.05” (12.83 cm)
128 Copyright © 2017, Juniper Networks, Inc.
Chapter 9: Preparation Overview
Figure 42: Chassis Dimensions and Clearance Requirements for the
MX960 Router with the Normal-Capacity Power Supplies
Total depth with extended cable manager
29.0”
(73.7 cm)
30" (76.2 cm) clearance recommended
27.8”
(70.6 cm)
23.0"
(58.4 cm)
Total depth with standard cable manager
30" (76.2 cm) clearance recommended for maintenance
Front of chassis
19.2"
(48.7 cm)
17.4"
(44.2 cm)
Rear of chassis
Standard cable manager
Extended cable manager
Front-mounting flange
Figure 43: Chassis Dimensions and Clearance Requirements for the
MX960 Router with the Standard Cable Manager and High-Capacity DC
Power Supplies
24" (61 cm) clearance required
34.8"
(88.4 cm)
24.5"
(62.2 cm)
39.3" (100 cm) clearance recommended
Front of chassis
19.2"
(48.7 cm)
17.4"
(44.2 cm)
Rear of chassis
Standard cable manager
Extended cable manager
Front-mounting flange
Related
Documentation
•
MX960 Rack Requirements on page 125
•
MX960 Rack-Mounting Hardware on page 14
•
MX960 Cabinet Size and Clearance Requirements on page 130
•
MX960 Cabinet Airflow Requirements on page 130
Copyright © 2017, Juniper Networks, Inc.
129
MX960 3D Universal Edge Router Hardware Guide
MX960 Cabinet Size and Clearance Requirements
The minimum size cabinet that can accommodate the router is 600 mm wide and
800 mm deep. A cabinet larger than the minimum requirement provides better airflow and reduces the chance of overheating. To accommodate a single router, the cabinet must be at least 16 U high. If you provide adequate cooling air and airflow clearance in a cabinet that has at least 48 U (89.3 in. or 224 mm) of usable vertical space, you can stack three routers with the standard cable manger installed, or two routers with the extended cable manager installed.
The minimum front and rear clearance requirements depend on the mounting configuration you choose. The minimum total clearance inside the cabinet is 39.4 in or
1000 mm. between the inside of the front door and the inside of the rear door.
Related
Documentation
•
Clearance Requirements for Airflow and Hardware Maintenance for the MX960 Router on page 128
•
MX960 Cabinet Airflow Requirements on page 130
•
MX960 Rack-Mounting Hardware on page 14
•
MX960 Rack Requirements on page 125
MX960 Cabinet Airflow Requirements
Before you install the router in a cabinet, you must ensure that ventilation through the cabinet is sufficient to prevent overheating. Consider the following requirements to when planning for chassis cooling:
• Ensure that the cool air supply you provide through the cabinet can adequately dissipate the thermal output of the router.
• Ensure that the cabinet allows the chassis hot exhaust air to exit from the cabinet without recirculating into the router. An open cabinet (without a top or doors) that employs hot air exhaust extraction from the top allows the best airflow through the chassis. If the cabinet contains a top or doors, perforations in these elements assist with removing the hot air exhaust. For an illustration of chassis airflow, see
• Install the router as close as possible to the front of the cabinet so that the cable manager just clears the inside of the front door. This maximizes the clearance in the rear of the cabinet for critical airflow.
• Route and dress all cables to minimize the blockage of airflow to and from the chassis.
130 Copyright © 2017, Juniper Networks, Inc.
Figure 44: Airflow Through the Chassis
Chapter 9: Preparation Overview
Related
Documentation
•
Clearance Requirements for Airflow and Hardware Maintenance for the MX960 Router on page 128
•
MX960 Cabinet Size and Clearance Requirements on page 130
•
MX960 Rack Requirements on page 125
•
MX960 Rack-Mounting Hardware on page 14
Copyright © 2017, Juniper Networks, Inc.
131
MX960 3D Universal Edge Router Hardware Guide
132 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 10
Transceiver and Cable Specifications
•
Network Cable and Transceiver Overview for ACX Series and M Series
•
Supported Network Interface Standards by Transceiver for ACX Series, MX Series, M
Series, and T Series Routers on page 134
•
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 139
•
Calculating Power Budget and Power Margin for Fiber-Optic Cables on page 140
•
Routing Engine Interface Cable and Wire Specifications for MX Series Routers on page 142
Network Cable and Transceiver Overview for ACX Series and M Series Routers
Juniper Networks devices support a variety of fixed and pluggable transceivers and network cable, including multimode and single-mode fiber-optic cable. For a list of transceivers supported on these platforms, see The Hardware Compatibility Tool .
For transceiver and cable specifications, see:
• Ethernet 10BASE-T Copper Interface Specifications
• Fast Ethernet 100BASE-T Copper Interface Specifications
• Gigabit Ethernet 1000BASE-T Copper Interface Specifications
• Fast Ethernet 100BASE-FX Optical Interface Specifications
• Fast Ethernet and Gigabit Ethernet Bidirectional SFP Optical Interface Specifications
• Gigabit Ethernet 1000BASE Optical Interface Specifications
• 10-Gigabit Ethernet 10GBASE Optical Interface Specifications
• 40-Gigabit Ethernet 40GBASE-R Optical Interface Specifications
• 100-Gigabit Ethernet 100GBASE-R Optical Interface Specifications
• SONET/SDH OC3/STM1 Optical Interface Specifications
• SONET/SDH OC12/STM4 Optical Interface Specifications
• SONET/SDH OC48/STM16 Optical Interface Specifications
• SONET/SDH OC192/STM64 Optical Interface Specifications
Copyright © 2017, Juniper Networks, Inc.
133
MX960 3D Universal Edge Router Hardware Guide
Related
Documentation
•
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 139
•
Calculating Power Budget and Power Margin for Fiber-Optic Cables on page 140
Supported Network Interface Standards by Transceiver for ACX Series, MX Series, M
Series, and T Series Routers
and
list the transceivers supported by ACX,
MX, M, and T Series devices.
NOTE: Not all transceivers are supported on all devices. To determine which transceivers are supported in a particular device, see the “Cables and
Connectors” section for each PIC, MIC, or line card in the Interface Module
Reference for your device, or see the Hardware Compatibility Tool .
TIP: You can use the Hardware Compatibility Tool to find information about the pluggable transceivers supported on your Juniper Networks device.
•
lists the supported Ethernet standards for each transceiver.
•
lists the supported SONET standards for each transceiver.
Some transceivers support monitoring by using the operational mode CLI command show interfaces diagnostics optics . To determine which transceivers support monitoring, refer to the “Monitoring Available” column in
and
.
For a description of the monitoring fields displayed by the transceiver, see show interfaces diagnostics optics (Gigabit Ethernet, 10-Gigabit Ethernet, 40-Gigabit Ethernet, 100-Gigabit
Ethernet, and Virtual Chassis Port) or show interfaces diagnostics optics (SONET) .
CAUTION: If you face a problem running a Juniper Networks device that uses a third-party optic or cable, the Juniper Networks Technical Assistance Center
(JTAC) can help you diagnose the source of the problem. Your JTAC engineer might recommend that you check the third-party optic or cable and potentially replace it with an equivalent Juniper Networks optic or cable that is qualified for the device.
NOTE: For XFP transceivers that can support either the 10-Gigabit Ethernet or SONET OC192/STM64 specifications, check the standard supported for the device into which the transceiver is installed. For example, the
XFP-10G-E-OC192-IR2 transceiver installed in a 10-Gigabit Ethernet PIC supports the 10GBASE-E standard. However, the XFP-10G-E-OC192-IR2 transceiver installed in a SONET OC192/STM64 PIC supports the SONET
OC192/STM64 IR2 standard.
134 Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Transceiver and Cable Specifications
is organized by transmission speed and then alphabetically by model number.
Table 67: Supported Ethernet Standards
Standard Transceiver Specifications
Ethernet 10BASE, Fast Ethernet 100BASE, and Gigabit Ethernet 1000BASE Specifications
100BASE-FX SFP-1FE-FX
10/100/1000 BASE-T
1000BASE-LH
SFP-1GE-FE-E-T
SFP-1GE-LH
1000BASE-LX
1000BASE-LX10
1000BASE-SX
SFP-1GE-LX
1000BASE-T
100BASE-BX
1000BASE-BX
SFP-1GE-SX
SFP-1GE-T
SFP-FE20KT13R15
SFP-FE20KT15R13
SFP-GE10KT13R14
SFP-GE10KT13R15
1000BASE-EX
SFP-GE10KT14R13
SFP-GE10KT15R13
SFP-GE40KT13R15
SFP-GE40KT15R13
SFP-GE40KM
Copyright © 2017, Juniper Networks, Inc.
135
MX960 3D Universal Edge Router Hardware Guide
10GBASE-ER
10GBASE-LR
10GBASE-Z
10GBASE-ER
10GBASE-LR
10GBASE-LRM
10GBASE-SR
10GBASE-ZR
10GBASE-ER
Table 67: Supported Ethernet Standards
(continued)
Standard Transceiver Specifications
SFP CWDM SFP-GE80KCW1470-ET
SFP-GE80KCW1490-ET
SFP-GE80KCw1510-ET
SFP-GE80KCW1530-ET
SFP-GE80KCW1550-ET
SFP-GE80KCW1570-ET
SFP-GE80KCW1590-ET
SFP-GE80KCW1610-ET
10-Gigabit Ethernet
10GBASE Specifications
10-Gigabit Ethernet dense wavelength-division multiplexing (DWDM)
10-Gigabit Ethernet dense wavelength-division multiplexing (DWDM) OTN
10GBASE-Z
SFPP-10GE-LRM
PC-1XGE-DWDM-CBAND
SFPP-10GE-LRM
PC-1XGE-DWDM-OTN
SFPP-10G-CT50-ZR
SFPP-10G-DT-ZRC2
SFPP-10G-ER-OTN
SFPP-10G-LR-OTN
SFPP-10G-ZR-OTN-XT
SFPP-10GE-ER
SFPP-10GE-LR
SFPP-10GE-LRM
SFPP-10GE-SR
SFPP-10GE-ZR
XENPAK-1XGE-ER
136 Copyright © 2017, Juniper Networks, Inc.
Table 67: Supported Ethernet Standards
(continued)
Standard Transceiver Specifications
10GBASE-LR
10GBASE-SR
10GBASE-Z
XENPAK-1XGE-LR
XENPAK-1XGE-SR
XENPAK-1XGE-ZR
EOL (see PSN-2010-02-649 )
XFP-10G-CBAND-T50-ZR 10GBASE-Z
10-Gigabit Ethernet dense wavelength-division multiplexing (DWDM)
10GBASE-E
10GBASE-L
10GBASE-S
10GBASE-Z
XFP-10G-E-OC192-IR2
XFP-10G-L-OC192-SR1
XFP-10G-S
XFP-10G-Z-OC192-LR2
40-Gigabit Ethernet 40GBASE Specifications
40GBASE-LR4 CFP-40GBASE-LR4
40GBASE-LX4
40GBASE-ER4
QSFPP-40G-LX4
QSFPP-40GBASE-ER4
40GBASE-LR4
40GBASE-SR4
QSFPP-40GBASE-LR4
QSFPP-40GBASE-SR4
100-Gigabit Ethernet 100GBASE-R Specifications
100GBASE-ER4 CFP-100GBASE-ER4
100GBASE-ER4
100GBASE-LR4
CFP-GEN2-CGE-ER4
CFP-100GBASE-LR4
100GBASE-LR4
100GBASE-SR10
CFP-GEN2-100GBASE-LR4
CFP-100GBASE-SR10
Juniper Networks Proprietary CFP-100GBASE-ZR
100GBASE-LR4 CFP2-100GBASE-LR4
Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Transceiver and Cable Specifications
137
MX960 3D Universal Edge Router Hardware Guide
Table 67: Supported Ethernet Standards
(continued)
Standard Transceiver Specifications
100GBASE-ER4
100GBASE-SR10
100GBASE-SR10
100G-SR4
100G-LR4
100-Gigabit DWDM OTN
CFP2-100G-ER4-D
CFP2-100G-SR10-D3
CXP-100GBASE-SR10
QSFP-100GBASE-SR4
CFP-100GBASE-LR4
TCFP2-100G-C
is organized by transmission speed and then alphabetically by model number.
Table 68: Supported SONET Standards
Standard Transceiver Specifications
SONET OC3/STM1 Specifications
SONET/SDH OC3/STM1
Intermediate Reach
SFP-OC3-IR
SONET/SDH OC3/STM1 Long
Reach
SFP-OC3-LR
SONET/SDH OC3/STM1
Multimode
SFP-OC3-SR
SONET OC12/STM4 Specifications
SONET/SDH OC12/STM4
Intermediate Reach (IR-1)
SFP-OC12-IR
SFP-OC12-LR SONET/SDH OC12/STM4
Long Reach (LR-1)
SONET/SDH OC12/STM4
Long Reach (LR-2)
SONET/SDH OC12/STM4
Short Reach (SR-1)
SFP-OC12-LR2
SFP-OC12-SR
SONET OC48/STM16 Specifications
SONET/SDH OC48/STM16
Intermediate Reach (IR-1)
SFP-1OC48-IR
138 Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Transceiver and Cable Specifications
Table 68: Supported SONET Standards
(continued)
Standard Transceiver Specifications
SFP-1OC48-LR SONET/SDH OC48/STM16
Long Reach (LR-2)
SONET/SDH OC48/STM16
Short Reach (SR-1)
SFP-1OC48-SR
SONET OC192/STM64 Specifications
SONET/SDH OC192/STM64
Intermediate Reach (IR-2)
XFP-10G-E-OC192-IR2
SONET/SDH OC192/STM64
Short Reach (SR-1)
XFP-10G-L-OC192-SR1
SONET/SDH OC192/STM64
Long Reach (LR-2)
XFP-10G-Z-OC192-LR2
SONET OC768/STM256 Specifications
SONET/SDH OC768/STM256
Short Reach (SR)
PD-1OC768-SON-SR
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion
This topic describes signal loss, attenuation, and dispersion in fiber-optic cable. For information about calculating power budget and power margin for fiber-optic cable, see
“Calculating Power Budget and Power Margin for Fiber-Optic Cables” on page 140
.
•
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable on page 139
•
Attenuation and Dispersion in Fiber-Optic Cable on page 140
Signal Loss in Multimode and Single-Mode Fiber-Optic Cable
Multimode fiber is large enough in diameter to allow rays of light to reflect internally
(bounce off the walls of the fiber). Interfaces with multimode optics typically use LEDs as light sources. However, LEDs are not coherent sources. They spray varying wavelengths of light into the multimode fiber, which reflects the light at different angles. Light rays travel in jagged lines through a multimode fiber, causing signal dispersion. When light traveling in the fiber core radiates into the fiber cladding, higher-order mode loss results.
Together these factors limit the transmission distance of multimode fiber compared with single-mode fiber.
Single-mode fiber is so small in diameter that rays of light can reflect internally through one layer only. Interfaces with single-mode optics use lasers as light sources. Lasers generate a single wavelength of light, which travels in a straight line through the single-mode fiber. Compared with multimode fiber, single-mode fiber has higher bandwidth and can carry signals for longer distances.
Copyright © 2017, Juniper Networks, Inc.
139
MX960 3D Universal Edge Router Hardware Guide
Exceeding the maximum transmission distances can result in significant signal loss, which causes unreliable transmission.
Attenuation and Dispersion in Fiber-Optic Cable
Correct functioning of an optical data link depends on modulated light reaching the receiver with enough power to be demodulated correctly.
Attenuation is the reduction in power of the light signal as it is transmitted. Attenuation is caused by passive media components, such as cables, cable splices, and connectors. Although attenuation is significantly lower for optical fiber than for other media, it still occurs in both multimode and single-mode transmission. An efficient optical data link must have enough light available to overcome attenuation.
Dispersion is the spreading of the signal over time. The following two types of dispersion can affect an optical data link:
• Chromatic dispersion—Spreading of the signal over time resulting from the different speeds of light rays.
• Modal dispersion—Spreading of the signal over time resulting from the different propagation modes in the fiber.
For multimode transmission, modal dispersion, rather than chromatic dispersion or attenuation, usually limits the maximum bit rate and link length. For single-mode transmission, modal dispersion is not a factor. However, at higher bit rates and over longer distances, chromatic dispersion rather than modal dispersion limits maximum link length.
An efficient optical data link must have enough light to exceed the minimum power that the receiver requires to operate within its specifications. In addition, the total dispersion must be less than the limits specified for the type of link in Telcordia Technologies document GR-253-CORE (Section 4.3) and International Telecommunications Union
(ITU) document G.957.
When chromatic dispersion is at the maximum allowed, its effect can be considered as a power penalty in the power budget. The optical power budget must allow for the sum of component attenuation, power penalties (including those from dispersion), and a safety margin for unexpected losses.
Related
Documentation
• Determining Transceiver Support and Specifications for Juniper Networks Devices
Calculating Power Budget and Power Margin for Fiber-Optic Cables
Use the information in this topic and the specifications for your optical interface to calculate the power budget and power margin for fiber-optic cables.
TIP: You can use the Hardware Compatibility Tool to find information about the pluggable transceivers supported on your Juniper Networks device.
140 Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Transceiver and Cable Specifications
To calculate the power budget and power margin, perform the following tasks:
1.
Calculating Power Budget for Fiber-Optic Cable on page 141
2.
Calculating Power Margin for Fiber-Optic Cable on page 141
Calculating Power Budget for Fiber-Optic Cable
To ensure that fiber-optic connections have sufficient power for correct operation, you need to calculate the link's power budget, which is the maximum amount of power it can transmit. When you calculate the power budget, you use a worst-case analysis to provide a margin of error, even though all the parts of an actual system do not operate at the worst-case levels. To calculate the worst-case estimate of power budget (P
B you assume minimum transmitter power (P
T
) and minimum receiver sensitivity (P
R
),
):
P
B
= P
T
– P
R
The following hypothetical power budget equation uses values measured in decibels
(dB) and decibels referred to one milliwatt (dBm):
P
B
= P
T
– P
R
P
B
= –15 dBm – (–28 dBm)
P
B
= 13 dB
Calculating Power Margin for Fiber-Optic Cable
After calculating a link's power budget, you can calculate the power margin (P
M
), which represents the amount of power available after subtracting attenuation or link loss (LL) from the power budget (P
B
). A worst-case estimate of P
M assumes maximum LL:
P
M
= P
B
– LL
P
M greater than zero indicates that the power budget is sufficient to operate the receiver.
Factors that can cause link loss include higher-order mode losses, modal and chromatic dispersion, connectors, splices, and fiber attenuation.
lists an estimated amount of loss for the factors used in the following sample calculations. For information about the actual amount of signal loss caused by equipment and other factors, refer to vendor documentation.
Table 69: Estimated Values for Factors Causing Link Loss
Link-Loss Factor Estimated Link-Loss Value
Higher-order mode losses
Modal and chromatic dispersion
Single-mode—None
Multimode—0.5 dB
Single-mode—None
Multimode—None, if product of bandwidth and distance is less than 500
MHz-km
Copyright © 2017, Juniper Networks, Inc.
141
MX960 3D Universal Edge Router Hardware Guide
Table 69: Estimated Values for Factors Causing Link Loss
(continued)
Link-Loss Factor Estimated Link-Loss Value
Connector
Splice
Fiber attenuation
0.5 dB
0.5 dB
Single-mode—0.5 dB/km
Multimode—1 dB/km
The following sample calculation for a 2-km-long multimode link with a power budget
(P
B
) of 13 dB uses the estimated values from
to calculate link loss
(LL) as the sum of fiber attenuation (2 km @ 1 dB/km, or 2 dB) and loss for five connectors
(0.5 dB per connector, or 2.5 dB) and two splices (0.5 dB per splice, or 1 dB) as well as higher-order mode losses (0.5 dB). The power margin (P
M
) is calculated as follows:
P
M
= P
B
– LL
P
M
= 13 dB – 2 km (1 dB/km) – 5 (0.5 dB) – 2 (0.5 dB) – 0.5 dB
P
M
= 13 dB – 2 dB – 2.5 dB – 1 dB – 0.5 dB
P
M
= 7 dB
The following sample calculation for an 8-km-long single-mode link with a power budget
(P
B
) of 13 dB uses the estimated values from
to calculate link loss
(LL) as the sum of fiber attenuation (8 km @ 0.5 dB/km, or 4 dB) and loss for seven connectors (0.5 dB per connector, or 3.5 dB). The power margin (P
M follows:
) is calculated as
P
M
= P
B
– LL
P
M
= 13 dB – 8 km (0.5 dB/km) – 7(0.5 dB)
P
M
= 13 dB – 4 dB – 3.5 dB
P
M
= 5.5 dB
In both examples, the calculated power margin is greater than zero, indicating that the link has sufficient power for transmission and does not exceed the maximum receiver input power.
Related
Documentation
•
Understanding Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 139
Routing Engine Interface Cable and Wire Specifications for MX Series Routers
lists the specifications for the cables that connect to management ports and the wires that connect to the alarm relay contacts.
142 Copyright © 2017, Juniper Networks, Inc.
Chapter 10: Transceiver and Cable Specifications
Table 70: Cable and Wire Specifications for Routing Engine Management and Alarm Interfaces
Port
Cable
Specification
Cable/Wire
Supplied
Maximum
Length
Router
Receptacle
RJ-45 female Routing Engine console or auxiliary interface
Routing Engine
Ethernet interface
Alarm relay contacts
RS-232
(EIA-232) serial cable
One 6-ft
(1.83-m) length with RJ-45/DB-9 connectors
6 ft (1.83 m)
Category 5 cable or equivalent suitable for
100Base-T operation
One 15-ft
(4.57-m) length with
RJ-45/RJ-45 connectors
328 ft (100 m)
Wire with gauge between
28-AWG and
14-AWG (0.08
and 2.08 mm
2
)
No None
RJ-45 autosensing
—
Related
Documentation
•
MX960 Routing Engine Description on page 29
•
Replacing Connections to MX960 Routing Engine Interface Ports on page 343
•
Replacing an MX960 Routing Engine on page 333
Copyright © 2017, Juniper Networks, Inc.
143
MX960 3D Universal Edge Router Hardware Guide
144 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 11
Pinout Specifications
•
MX960 Router Grounding Specifications on page 145
•
RJ-45 Connector Pinouts for an MX Series Routing Engine ETHERNET Port on page 148
•
RJ-45 Connector Pinouts for MX Series Routing Engine AUX and CONSOLE
MX960 Router Grounding Specifications
•
MX960 Chassis Grounding Points Specifications on page 145
•
MX960 Router Grounding Cable Lug Specifications on page 147
•
MX960 Router Grounding Cable Specifications on page 148
MX960 Chassis Grounding Points Specifications
To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, the router must be adequately grounded before power is connected.
To ground AC-powered and DC-powered routers, you must connect a grounding cable to earth ground and then attach it to the chassis grounding points using the two screws provided. Two threaded inserts (PEM nuts) are provided on the right of the lower rear of the chassis for connecting the router to earth ground (see
or
).
Copyright © 2017, Juniper Networks, Inc.
145
MX960 3D Universal Edge Router Hardware Guide
Figure 45: Connecting AC Power to the Router
146 Copyright © 2017, Juniper Networks, Inc.
Figure 46: Connecting DC Power to the Router
Chapter 11: Pinout Specifications
MX960 Router Grounding Cable Lug Specifications
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the grounding and power cables that you supply. A cable with an incorrectly attached lug can damage the router.
To ground AC-powered and DC-powered routers, connect a grounding cable to earth ground and then attach it to the chassis grounding points using two screws. The left pair of grounding points fits M6 screws (European), and the right pair fits UNC 1/4–20 screws
(English). The grounding points are spaced at 0.625-in. (15.86-mm) centers. The accessory box shipped with the router includes the cable lug that attaches to the grounding cable (see
Figure 47 on page 148 ) and two UNC 1/4–20 screws used to secure
the grounding cable to the right pair of grounding points.
WARNING: The router is a pluggable type A equipment installed in a restricted access location. It has a separate protective earthing terminal (Metric [–M6] and English [–¼-20] screw ground lugs) provided on the chassis in addition to the grounding pin of the power supply cord. This separate protective earth terminal must be permanently connected to earth.
Copyright © 2017, Juniper Networks, Inc.
147
MX960 3D Universal Edge Router Hardware Guide
Figure 47: Grounding Cable Lug
2.25
End view
0.55
0.28
diameter each hole
6 AWG conductor
0.25
0.625
0.37
Crimp area
All measurements in inches 0.08
MX960 Router Grounding Cable Specifications
The 48 VDC facility must be equipped with a circuit breaker rated 40 A (–48 VDC), or
60 A (–48 VDC), and the grounding cable must be minimum 10 AWG, or as required by the local code.
NOTE: Additional grounding is provided to an AC-powered router when you plug its power supplies into grounded AC power receptacles.
WARNING: The router is installed in a restricted-access location. It has a separate protective earthing terminal (Metric [–M6] and English [–¼-20] screw ground lugs) provided on the chassis in addition to the grounding pin of the power supply cord. This separate protective earth terminal must be permanently connected to earth.
Related
Documentation
•
Grounding the MX960 Router on page 226
•
Tools and Parts Required for MX960 Router Grounding and Power Connections on page 225
RJ-45 Connector Pinouts for an MX Series Routing Engine ETHERNET Port
1
2
3
The port on the Routing Engine labeled ETHERNET is an autosensing 10/100-Mbps
Ethernet RJ-45 receptacle that accepts an Ethernet cable for connecting the Routing
Engine to a management LAN (or other device that supports out-of-band management).
describes the RJ-45 connector pinout.
Table 71: RJ-45 Connector Pinout for the Routing Engine ETHERNET Port
Pin Signal
TX+
TX–
RX+
148 Copyright © 2017, Juniper Networks, Inc.
Chapter 11: Pinout Specifications
6
7
4
5
Table 71: RJ-45 Connector Pinout for the Routing Engine ETHERNET
Port
(continued)
Pin Signal
Termination network
Termination network
RX–
Termination network
8 Termination network
Related
Documentation
•
MX960 Routing Engine Description on page 29
•
Replacing Connections to MX960 Routing Engine Interface Ports on page 343
•
Replacing an MX960 Routing Engine on page 333
RJ-45 Connector Pinouts for MX Series Routing Engine AUX and CONSOLE Ports
3
4
1
2
The ports on the Routing Engine labeled AUX and CONSOLE are asynchronous serial interfaces that accept an RJ-45 connector. The ports connect the Routing Engine to an auxiliary or console management device.
describes the RJ-45 connector pinout.
Table 72: RJ-45 Connector Pinout for the AUX and CONSOLE Ports
Pin Signal Description
RTS
DTR
TXD
Ground
Request to Send
Data Terminal Ready
Transmit Data
Signal Ground
7
8
5
6
Ground
RXD
DSR/DCD
CTS
Signal Ground
Receive Data
Data Set Ready
Clear to Send
Copyright © 2017, Juniper Networks, Inc.
149
MX960 3D Universal Edge Router Hardware Guide
Related
Documentation
•
MX960 Routing Engine Description on page 29
•
Replacing Connections to MX960 Routing Engine Interface Ports on page 343
•
Replacing an MX960 Routing Engine on page 333
150 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 12
AC Power Requirements, Specifications, and Guidelines
•
Electrical Specifications for the MX960 AC Power Supply on page 151
•
Power Requirements for an MX960 Router on page 152
•
Calculating Power Requirements for MX960 Routers on page 161
•
AC Power Circuit Breaker Requirements for the MX960 Router on page 165
•
AC Power Cord Specifications for the MX960 Router on page 165
Electrical Specifications for the MX960 AC Power Supply
lists the AC power supply electrical specifications.
lists the AC power system specifications.
Table 73: AC Power Supply Electrical Specifications
Item Specification
Normal-Capacity Power Supply
Maximum output power 1700 W
AC nominal input voltage Operating range: 200 to 240 VAC
AC input line frequency 50 to 60 Hz
AC input current rating 11 A @ 240 VAC maximum
Efficiency
NOTE: This value is at full load and nominal voltage.
88%
High-Capacity Power Supply
Maximum output power Two-feed mode
4100 W
AC nominal input voltage Operating range: 200 to 240 VAC
One-feed mode
1700 W
Copyright © 2017, Juniper Networks, Inc.
151
MX960 3D Universal Edge Router Hardware Guide
Table 73: AC Power Supply Electrical Specifications
(continued)
Item Specification
AC input line frequency
AC input current rating
50 to 60 Hz
Two-feed mode
26 A (13 A per feed)
Maximum AC inrush current 76 A (38 A per feed at 264 VAC)
Efficiency
NOTE: This value is at full load and nominal voltage.
~88%
Table 74: AC Power System Specifications
Item Normal-Capacity
Redundancy 3+1
Output power (maximum) per supply
1700 W
Output power (maximum) per system
5100 W
High-Capacity
All PEMs in two-feed mode
2+2
4100 W
8200 W
One-feed mode
13 A
38 A per feed at 264 VAC
All PEMs in one-feed mode
2+2
1700 W
3400 W
Related
Documentation
•
MX960 AC Power Supply Description on page 98
•
Replacing an MX960 AC Power Supply on page 391
•
Installing an MX960 AC Power Supply on page 290
• show chassis power
Power Requirements for an MX960 Router
lists the MX960 base system and cooling system power requirements.
lists the FRU power requirements for Switch Control Boards (SCBs),
Routing Engines, Modular Port Concentrators (MPCs), Modular Interface Cards (MICs),
Dense Port Concentrators (DPCs), and PICs. In addition,
lists the
MPC power requirements with MICs and optics at various operating temperatures.
Typical power represents power under certain temperatures and normal operating conditions.
152 Copyright © 2017, Juniper Networks, Inc.
Chapter 12: AC Power Requirements, Specifications, and Guidelines
Table 75: MX960 Common Component Power Requirements
Component Maximum Power Requirement Typical Power Requirement
Base system
Normal-capacity cooling system
High-capacity cooling system
50 W
600 W (full speed)
640 W (full speed)
50 W
400 W (normal speed)
450 W (normal speed)
Table 76: FRU Power Requirements
Component Part Number Maximum Power Requirement
Switch Control Boards (SCBs)
SCB SCB-MX960
(applies to
MX240, MX480, and MX960)
150 W
SCBE
SCBE2
SCBE-MX
(applies to
MX240, MX480, and MX960)
160 W at 55° C
130 W at 40° C
120 W at 25° C
SCBE2-MX
(applies to
MX240, MX480, and MX960)
185 W at 55° C
160 W at 40° C
155 W at 25° C
Routing Engines
Routing
Engines
RE-S-1300-2048
RE-S-1800X2-8G
90 W
RE-S-1800X4-8G
RE-S-1800X2-16G
RE-S-1800X4-16G
RE-S-1800X4-32G
RE-S-2000-4096
RE-S-X6-64G
Fixed Configuration MPCs
16x10GE MPC MPC-3D-16XGE-SFPP 440 W at 55° C ambient
MPC-3D-16XGE-SFPP-R-B 423 W at 25° C ambient
Multiservices
MPC
MS-MPC-128G 590 W
Copyright © 2017, Juniper Networks, Inc.
153
MX960 3D Universal Edge Router Hardware Guide
6x40GE +
24x10GE
MPC5E
6x40GE +
24x10GE
MPC5EQ
2x100GE +
4x10GE
MPC5E
2x100GE +
4x10GE
MPC5EQ
MPC7E
(Multi-Rate)
Table 76: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
32x10GE
MPC4E
2x100GE +
8x10GE
MPC4E
MPC4E-3D-32XGE-SFPP 610 W
With optics:
607 W at 55° C, with SFPP ZR optics
584 W at 40° C, with SFPP ZR optics
565 W at 25° C, with SFPP ZR optics
MPC4E-3D-2CGE-8XGE 610 W
With optics:
607 W at 55° C, with SFPP ZR and CFP LR4 optics
584 W at 40° C, with SFPP ZR and CFP LR4 optics
565 W at 25° C, with SFPP ZR and CFP LR4 optics
MPC5E-40G10G
MPC5EQ-40G10G
With optics:
607 W at 55° C
541 W at 40° C
511 W at 25° C
MPC5E-100G10G
MPC5EQ-100G10G
With optics:
607 W at 55° C
541 W at 40° C
511 W at 25° C
MPC7E-MRATE With optics:
545 W at 55° C
465 W at 40° C
440 W at 25° C
MPCs
MPC1
MPC1E
MX-MPC1-3D
MX-MPC1E-3D
165 W
With MICs and optics:
239 W at 55° C
227 W at 40° C
219 W at 25° C
154 Copyright © 2017, Juniper Networks, Inc.
Chapter 12: AC Power Requirements, Specifications, and Guidelines
Table 76: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
MPC1 Q
MPC1E Q
MPC2
MPC2E
MPC2 Q
MPC2E Q
MPC2 EQ
MPC2E EQ
MPC2E P
MPC2E NG
MX-MPC1-3D-Q 175 W
MX-MPC1E-3D-Q With MICs and optics:
249 W at 55° C
237 W at 40° C
228 W at 25° C
MX-MPC2-3D
MX-MPC2E-3D
274 W
With MICs and optics:
348 W at 55° C
329 W at 40° C
315 W at 25° C
MX-MPC2-3D-Q 294 W
MX-MPC2E-3D-Q With MICs and optics:
368 W at 55° C
MX-MPC2-3D-EQ
MX-MPC2E-3D-EQ
347 W at 40° C
333 W at 25° C
MX-MPC2E-3D-P 294 W
With MICs and optics:
368 W at 55° C
347 W at 40° C
333 W at 25° C
MPC2E-3D-NG 474 W
With MICs and optics:
474 W at 55° C
417 W at 40° C
400 W at 25° C
MPC2E NG Q MPC2E-3D-NG-Q 529 W
With MICs and optics:
529 W at 55° C
460 W at 40° C
438 W at 25° C
Copyright © 2017, Juniper Networks, Inc.
155
MX960 3D Universal Edge Router Hardware Guide
Table 76: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
MPC3E
MPC3E NG
MX-MPC3E-3D
MPC3E-3D-NG
440 W
With MICs and optics:
500 W at 55° C, two 40W MICs
485 W at 40° C, two CFP MICs with LR4 optics
473 W at 25° C, two CFP MICs with LR4 optics
534 W
With MICs and optics:
534 W at 55° C
485 W at 40° C
461 W at 25° C
MPC3E NG Q MPC3E-3D-NG-Q 583 W
With MICs and optics:
583 W at 55° C
532 W at 40° C
503 W at 25° C
MICs
ATM MIC with
SFP
MPC4E-3D-2CGE-8XGE 610 W
With optics:
607 W at 55° C, with SFPP ZR and CFP LR4 optics
584 W at 40° C, with SFPP ZR and CFP LR4 optics
565 W at 25° C, with SFPP ZR and CFP LR4 optics
35 W
Gigabit
Ethernet MIC with SFP
MIC-3D-20-GE-SFP 37 W
10-Gigabit
Ethernet MIC with XFP
2-Port:
MIC-3D-2XGE-XFP
2-Port: 29 W
4-Port: 37 W
4-Port:
MIC-3D-4XGE-XFP
10-Gigabit
Ethernet MIC with SFP+
MIC3-3D-10XGE-SFPP 24.2 W at 55° C with SR and LR optics
29.8 W at 55° C with ER optics
29.8 W at 40° C with ZR optics
156 Copyright © 2017, Juniper Networks, Inc.
Chapter 12: AC Power Requirements, Specifications, and Guidelines
Table 76: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
40-Gigabit
Ethernet MIC with QSFP+
MIC3-3D-2X40GE-QSFPP 18 W
100-Gigabit
Ethernet MIC with CFP
MIC3-3D-1X100GE-CFP 40 W
100-Gigabit
Ethernet MIC with CXP
MIC3-3D-1X100GE-CXP 20 W
100-Gigabit
DWDM OTN
MIC with CFP2
MIC3-100G-DWDM With optics:
91 W at 55° C
83 W at 25° C
Multiservices
MIC
MS-MIC-16G
SONET/SDH
OC3/STM1
Multi-Rate
MIC
60 W
4-Port:
MIC-3D-4OC3OC12-1OC48
4-Port:
24 W at 55° C
22.75 W at 40° C
21.5 W at 25° C
8-Port:
MIC-3D-8OC3OC12-4OC48
8-Port:
29 W at 55° C
27.75 W at 40° C
26.5 W at 25° C
SONET/SDH
OC192/STM64
MIC with XFP
MIC-3D-1OC192-XFP 41 W at 55° C
38.5 W at 40° C
36 W at 25° C
Copyright © 2017, Juniper Networks, Inc.
157
MX960 3D Universal Edge Router Hardware Guide
Table 76: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
Channelized
SONET/SDH
OC3/STM1
Multi-Rate
MIC
4-Port:
MIC-3D-4CHOC3-2CHOC12
4-Port:
41 W at 55° C
40 W at 40° C
39 W at 25° C
Tri-Rate MIC
DS3/E3 MIC
8-Port:
MIC-3D-8CHOC3-4CHOC12
8-Port:
52 W at 55° C
50.5 W at 40° C
49 W at 25° C
MIC-3D-40GE-TX 41 W
MIC-3D-8DS3-E3 36 W at 55° C
MIC-3D-8CHDS3-E3-B 35 W at 40° C
34 W at 25° C
Channelized
E1/T1 Circuit
Emulation MIC
MIC-3D-16CHE1-T1-CE 29.08 W at 55° C
27.84 W at 40° C
26.55 W at 25° C
Channelized
OC3/STM1
(Multi-Rate)
Circuit
Emulation MIC with SFP
MIC-3D-4COC3-1COC12-CE 36.48 W at 55° C
35.04 W at 40° C
33.96 W at 25° C
DPCs
Gigabit
Ethernet DPC with SFP
DPC-R-40GE-SFP 335 W
Gigabit
Ethernet
Enhanced DPC with SFP
DPCE-R-40GE-SFP
DPCE-X-40GE-SFP
335 W
158 Copyright © 2017, Juniper Networks, Inc.
Chapter 12: AC Power Requirements, Specifications, and Guidelines
Table 76: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
Gigabit
Ethernet
Enhanced
Queuing
Ethernet
Services DPC with SFP
(40-Port)
DPCE-R-Q-40GE-SFP 365 W
DPCE-X-Q-40GE-SFP
Gigabit
Ethernet
Enhanced
Queuing IP
Services DPCs with SFP
(20-Port)
DPCE-R-Q-20GE-SFP 200 W
10-Gigabit
Ethernet DPC with XFP
DPC-R-4XGE-XFP 310 W
10-Gigabit
Ethernet
Enhanced DPC with XFP
(2-Port)
DPCE-R-2XGE-XFP 175 W
10-Gigabit
Ethernet
Enhanced DPC with XFP
(4-Port)
DPCE-R-4XGE-XFP
DPCE-X-4XGE-XFP
310 W
10-Gigabit
Ethernet
Enhanced
Queuing
Ethernet
Services DPC with XFP or
Enhanced
Queuing IP
Services DPC with XFP
DPCE-R-Q-4XGE-XFP 330 W
DPCE-X-Q-4XGE-XFP
Copyright © 2017, Juniper Networks, Inc.
159
MX960 3D Universal Edge Router Hardware Guide
Table 76: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
Multi-Rate
Ethernet
Enhanced DPC with SFP and
XFP or
Multi-Rate
Ethernet
Enhanced
Ethernet
Services DPC with SFP and
XFP
DPCE-R-20GE-2XGE
DPCE-X-20GE-2XGE
333 W
Multi-Rate
Ethernet
Enhanced
Queuing IP
Services DPC with SFP and
XFP
DPCE-R-Q-20GE-2XGE 335 W
Tri-Rate
Enhanced DPC or Tri-Rate
Enhanced
Ethernet
Services DPC
DPCE-R-40GE-TX
DPCE-X-40GE-TX
320 W
Multiservices
DPC
MS-DPC 265 W
FPCs
FPC Type 2
FPC Type 3
MX-FPC2
MX-FPC3
190 W (with PICs and optics)
265 W (with PICs and optics)
Related
Documentation
•
Electrical Specifications for the MX960 DC Power Supply on page 169
•
Electrical Specifications for the MX960 AC Power Supply on page 151
160 Copyright © 2017, Juniper Networks, Inc.
Chapter 12: AC Power Requirements, Specifications, and Guidelines
Calculating Power Requirements for MX960 Routers
The information in this topic helps you determine which power supplies are suitable for various configurations, as well as which power supplies are not suitable because output power is exceeded. You determine suitability by subtracting the total power draw from the maximum output of the power supplies. Afterward, the required input current is calculated. Finally, you calculate the thermal output. A sample configuration is provided in
.
We recommend that you provision power according to the maximum input current listed in the power supply electrical specifications (see
“Electrical Specifications for the MX960
and
“Electrical Specifications for the MX960 DC Power
Use the following procedures to calculate the power requirement:
1.
Calculate the power requirement.
2.
Evaluate the power budget.
3.
Calculate input power.
4.
Calculate thermal output (BTUs) for cooling requirements.
Copyright © 2017, Juniper Networks, Inc.
161
MX960 3D Universal Edge Router Hardware Guide
Both normal-capacity and high-capacity MX960 chassis with DC power supplies and
MX960 chassis with high-capacity AC power supplies are zoned. MX960 chassis with normal-capacity AC power supplies have one overall zone. Zoning means that certain components are powered by specific power supplies (see
for information on zoning). When calculating power requirements, be sure that there is adequate power for each zone.
Three AC power supplies are mandatory for MX960 chassis with normal-capacity AC power supplies.
Table 77: MX960 Zoning
Chassis Power Configuration Zone
Power Supply
(PEM) Components Receiving Power
MX960 DC (normal-capacity and high-capacity power supplies); MX960 AC (high-capacity power supplies)
Zone 0
MX960 DC (normal-capacity and high-capacity power supplies); MX960 AC (high-capacity power supplies)
Zone 1
PEM 0 or 2
PEM 1 or 3
•
•
•
Lower fan tray
DPC/MPC slots 6 through 11
SCB slots 1 through 2
•
•
•
Upper fan tray
DPC/MPC slots 0 through 5
SCB slot 0
The following sample configuration shows an MX960 chassis with:
• Four high-capacity AC power supplies (using two feeds for each power supply); two supplies are active, two are redundant
• Six 16 port 10 GbE MPC with SFP+ interfaces (slots 0 through 5)
• Two SCBs with two (redundant) RE-1800x2 routing engines (SCB slot 0 and SCB slot
1)
• SCB (SCB slot 6)
• Five 16 port 10 GbE MPC with SFP+ interfaces (slots 7 through 11)
• High-capacity cooling system (upper and lower fan trays)
NOTE: The high-capacity cooling system satisfies cooling requirements of MPCs, and must be used for proper cooling.
162 Copyright © 2017, Juniper Networks, Inc.
Chapter 12: AC Power Requirements, Specifications, and Guidelines
1.
Calculate the power requirements (usage) using the values in
“Power Requirements for an MX960 Router” on page 152
as shown in
Table 78: Sample Power Requirements for an MX960 Router
Chassis Component Part Number Power Requirement Zone
Base system MX960BASE-AC-HIGH 50 W
1
—
High-capacity cooling system FFANTRAY-MX960-HC 320 W * 2 = 640 W Zone 0 (lower fan tray) and Zone 1 (upper fan tray)
Zone 1
Zone 0
Zone 1
MPC - slots 0 through 5
MPC - slots 7 through 11
SCB 0
SCB 1
MPC-3D-16XGE-SFPP
MPC-3D-16XGE-SFPP
SCBE2-MX with
RE-S-1800X2-8G
SCBE2-MX with
RE-S-1800X2-8G
SCB 2 - slot 6 SCBE2-MX
MX960 normal-capacity AC (not zoned)
Zone 0 total output power
Zone 1 total output power
440 W * 6 = 2640 W
440 W * 5 = 2200 W
185 W
90 W
185 W
90 W
185 W
6265 W
3005 W
3260 W
1
Divided equally between zone 0 and zone 1.
Zone 0
Zone 0
2.
Evaluate the power budget, including the budget for each zone if applicable. In this step, we check the required power against the maximum output power of available power supply options.
lists the power supplies, their maximum output power, and unused power (or a power deficit).
Table 79: Calculating Power Budget
Power Supply
Maximum Output
Power of Power
Supply
Maximum Output
Power for System
Nonzoned
Unused Power
Zone 0 Unused
Power
1
Zone 1 Unused
Power
2
MX960 AC normal-capacity
1700 W 5100 W Power exceeded
(non-zoned;
5100 W - 6160 = power exceeded)
– –
Copyright © 2017, Juniper Networks, Inc.
163
MX960 3D Universal Edge Router Hardware Guide
Table 79: Calculating Power Budget
(continued)
Power Supply
Maximum Output
Power of Power
Supply
Maximum Output
Power for System
Nonzoned
Unused Power
Zone 0 Unused
Power
1
Zone 1 Unused
Power
2
MX960 AC high-capacity
MX960 DC normal-capacity
MX960 DC high-capacity
1700 W (one feed)
4100 W (two feeds)
3400 W (one feed)
8200 W (two feeds)
–
2800 W 5600 W –
1700 W (one feed)
4100 W (two feeds)
3400 W (one feed)
8200 W (two feeds)
–
Power exceeded Power exceeded
1165 W 875 W
Power exceeded Power exceeded
Power exceeded Power exceeded
1165 W 875 W
1
For this configuration, output power is 2935 W.
2
For this configuration, output power is 3225 W.
3.
Calculate input power. In this step, the input power requirements for the example configuration are calculated. To do this, divide the total output requirement by the efficiency of the power supply as shown in
.
NOTE: MX960 AC and MX960 DC normal-capacity power supplies are not included in the following table, because their power budget was exceeded in the sample configuration.
Table 80: Calculating Input Power
Power Supply
MX960 AC high-capacity
MX960 DC high-capacity
Power Supply Efficiency
1
~88 %
86 %
Input Power Requirement
2
3335 W
3
3413 W
3
1
These values are at full load and nominal voltage.
2
For this configuration, total power for zone 0 is 2935 W. The calculation method for zone 1 is the same as zone 0.
3
Zone 0 requirement.
4.
Calculate thermal output (BTUs). To calculate this, multiply the input power requirement (in watts) by 3.41 as shown in
164 Copyright © 2017, Juniper Networks, Inc.
Chapter 12: AC Power Requirements, Specifications, and Guidelines
Table 81: Calculating Thermal Output
Power Supply
MX960 AC high-capacity
MX960 DC high-capacity
Thermal Output (BTUs per hour)
3335 * 3.41 = 11,372 BTU/hr
1
3413 * 3.41 = 11,638 BTU/hr
1
1
Zone 0 output. The calculation method for zone 1 is the same as for zone 0.
Related
Documentation
•
Power Requirements for an MX960 Router on page 152
•
Electrical Specifications for the MX960 AC Power Supply on page 151
•
Electrical Specifications for the MX960 DC Power Supply on page 169
AC Power Circuit Breaker Requirements for the MX960 Router
Each AC power supply has a single AC appliance inlet located in the chassis directly above the power supply that requires a dedicated AC power feed. We recommend that you use a dedicated customer site circuit breaker rated for 15 A (250 VAC) minimum for each AC power supply, or as required by local code.
Each high-capacity AC PEM accepts two AC feeds in two unique AC receptacles. We recommend that you use a dedicated customer site circuit breaker rated for
38 A (264 VAC) minimum for each high- capacity AC power supply, or as required by local code.
Related
Documentation
•
MX960 AC Power Supply Description on page 98
• MX960 AC Power Electrical Safety Guidelines and Warnings
•
Replacing an MX960 AC Power Supply on page 391
AC Power Cord Specifications for the MX960 Router
Each normal capacity AC power supply has a single AC appliance inlet located in the chassis directly above the power supply that requires a dedicated AC power feed and each high-capacity AC PEM accepts two AC feeds in two unique AC receptacles. Most sites distribute power through a main conduit that leads to frame-mounted power distribution panels, one of which can be located at the top of the rack that houses the router. An AC power cord connects each power supply to the power distribution panel.
You can order detachable AC power cords, each approximately 8 ft (2.5 m) long that supply AC power to the router. The C19 appliance coupler at the female end of the cord inserts into the AC appliance inlet coupler, type C20 (right angle) as described by
International Electrotechnical Commission (IEC) standard 60320. The plug at the male end of the power cord fits into the power source receptacle that is standard for your geographical location. If you want to use two AC feeds, two power cords are needed for
Copyright © 2017, Juniper Networks, Inc.
165
MX960 3D Universal Edge Router Hardware Guide each HC AC power supply. For more information about AC power supplies, see
AC Power Supply Description” on page 98
.
provides specifications and
depicts the plug on the AC power cord provided for each country or region.
Table 82: AC Power Cord Specifications
Country Electrical Specification Plug Type
Australia
China
Europe (except Denmark, Italy, Switzerland, and United Kingdom)
Italy
240 VAC, 50 Hz AC
220 VAC, 50 Hz AC
SAA/3
PSB-10
220 or 230 VAC, 50 Hz AC CEE 7/7
230 VAC, 50 Hz AC CEI 23-16/VII
Japan
North America
United Kingdom
220 VAC, 50 or 60 Hz AC
250 VAC, 60 Hz AC
240 VAC, 50 Hz AC
NEMA L6-20P
NEMA L6-20P
BS89/13
Figure 48: AC Plug Types
Australia
(SAA/3)
China
(PSB-10)
Europe
(CEE 7/7)
Italy
(CEI 23-16/VII)
Japan
(L6-20P)
North America
(L6-20P)
North America
NEMA
(L6-20)
UK
(BS89/13)
WARNING: The AC power cord for the router is intended for use with the router only and not for any other use.
166 Copyright © 2017, Juniper Networks, Inc.
Chapter 12: AC Power Requirements, Specifications, and Guidelines
WARNING:
Translation from Japanese: The attached power cable is only for this product.
Do not use the cable for another product.
NOTE: In North America, AC power cords must not exceed 4.5 m
(approximately 14.75 ft) in length, to comply with National Electrical Code
(NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52, and Canadian Electrical
Code (CEC) Section 4-010(3). You can order AC power cords that are in compliance.
WARNING: The router is a pluggable type A equipment installed in restricted access location. It has a separate protective earthing terminal (Metric [–M6] and English [–¼-20] screw ground lugs) provided on the chassis in addition to the grounding pin of the power supply cord. This separate protective earth terminal must be permanently connected to earth.
CAUTION: Power cords and cables must not block access to device components or drape where people could trip on them.
Related
Documentation
•
MX960 AC Power Supply Description on page 98
•
Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power
•
Replacing an MX960 AC Power Supply Cord on page 403
Copyright © 2017, Juniper Networks, Inc.
167
MX960 3D Universal Edge Router Hardware Guide
168 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 13
DC Power Requirements, Specifications, and Guidelines
•
Electrical Specifications for the MX960 DC Power Supply on page 169
•
Power Requirements for an MX960 Router on page 171
•
Calculating Power Requirements for MX960 Routers on page 179
•
DC Power Circuit Breaker Requirements for the MX960 Router on page 183
•
DC Power Source Cabling for the MX960 Router on page 183
•
DC Power Cable Specifications for the MX960 Router on page 185
Electrical Specifications for the MX960 DC Power Supply
lists the DC power supply electrical specifications.
Table 83: Power Supply Electrical Specifications
Item Specification
Normal-Capacity Power Supplies
Maximum output power
DC input current rating
Maximum input current
DC input voltage
2800 W
58 A @ –48 V nominal operating voltage
70 A
Operating range: –40 to –72 VDC
Nominal: –48 VDC
Internal Circuit Breaker 80 A
Efficiency
NOTE: This value is at full load and nominal voltage.
99%
Copyright © 2017, Juniper Networks, Inc.
169
MX960 3D Universal Edge Router Hardware Guide
Table 83: Power Supply Electrical Specifications
(continued)
Item Specification
High-Capacity Power Supplies
Maximum output power Two-Feed Mode
DC input voltage
4100 W
Nominal: –48 VDC
Operating range: –40 to –72 VDC
DC nominal input current rating @48 VDC
Two-Feed Mode
104 A for both feeds (54 A and 50 A per feed)
128 A for both feeds (66 A and 62 A per feed) Maximum input current rating @ 40 VDC input voltage
One-Feed Mode
1700 W
One-Feed Mode
42 A
52 A
Maximum DC inrush current 140.5 A for both feeds (70 A and 70.5 A per feed
Efficiency
NOTE: This value is at full load and nominal voltage.
86%
70 A
Table 84: Power System Electrical Specifications
Item Normal-Capacity High-Capacity
Redundancy 2+2
Output power (maximum) per supply
2800 W
Output power (maximum) per system
5600 W
2+2
Two-feed mode
4100 W
8200 W
One-feed mode
1700 W
3400 W
Related
Documentation
•
Calculating Power Requirements for MX960 Routers on page 161
•
MX960 DC Power Supply on page 104
• MX960 DC Power Electrical Safety Guidelines
• show chassis power
170 Copyright © 2017, Juniper Networks, Inc.
Chapter 13: DC Power Requirements, Specifications, and Guidelines
Power Requirements for an MX960 Router
lists the MX960 base system and cooling system power requirements.
lists the FRU power requirements for Switch Control Boards (SCBs),
Routing Engines, Modular Port Concentrators (MPCs), Modular Interface Cards (MICs),
Dense Port Concentrators (DPCs), and PICs. In addition,
lists the
MPC power requirements with MICs and optics at various operating temperatures.
Typical power represents power under certain temperatures and normal operating conditions.
Table 85: MX960 Common Component Power Requirements
Component Maximum Power Requirement Typical Power Requirement
Base system
Normal-capacity cooling system
50 W
600 W (full speed)
50 W
400 W (normal speed)
High-capacity cooling system 640 W (full speed) 450 W (normal speed)
Table 86: FRU Power Requirements
Component Part Number Maximum Power Requirement
Switch Control Boards (SCBs)
SCB SCB-MX960
(applies to
MX240, MX480, and MX960)
150 W
SCBE
SCBE2
SCBE-MX
(applies to
MX240, MX480, and MX960)
160 W at 55° C
130 W at 40° C
120 W at 25° C
SCBE2-MX
(applies to
MX240, MX480, and MX960)
185 W at 55° C
160 W at 40° C
155 W at 25° C
Routing Engines
Copyright © 2017, Juniper Networks, Inc.
171
MX960 3D Universal Edge Router Hardware Guide
Table 86: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
Routing
Engines
RE-S-1300-2048 90 W
RE-S-1800X2-8G
RE-S-1800X4-8G
RE-S-1800X2-16G
RE-S-1800X4-16G
RE-S-1800X4-32G
RE-S-2000-4096
RE-S-X6-64G
Fixed Configuration MPCs
16x10GE MPC MPC-3D-16XGE-SFPP 440 W at 55° C ambient
MPC-3D-16XGE-SFPP-R-B 423 W at 25° C ambient
MS-MPC-128G 590 W Multiservices
MPC
32x10GE
MPC4E
MPC4E-3D-32XGE-SFPP 610 W
With optics:
607 W at 55° C, with SFPP ZR optics
584 W at 40° C, with SFPP ZR optics
565 W at 25° C, with SFPP ZR optics
2x100GE +
8x10GE
MPC4E
6x40GE +
24x10GE
MPC5E
6x40GE +
24x10GE
MPC5EQ
MPC4E-3D-2CGE-8XGE 610 W
With optics:
607 W at 55° C, with SFPP ZR and CFP LR4 optics
584 W at 40° C, with SFPP ZR and CFP LR4 optics
565 W at 25° C, with SFPP ZR and CFP LR4 optics
MPC5E-40G10G
MPC5EQ-40G10G
With optics:
607 W at 55° C
541 W at 40° C
511 W at 25° C
172 Copyright © 2017, Juniper Networks, Inc.
Chapter 13: DC Power Requirements, Specifications, and Guidelines
Table 86: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
2x100GE +
4x10GE
MPC5E
2x100GE +
4x10GE
MPC5EQ
MPC7E
(Multi-Rate)
MPC5E-100G10G
MPC5EQ-100G10G
With optics:
607 W at 55° C
541 W at 40° C
511 W at 25° C
MPC7E-MRATE With optics:
545 W at 55° C
465 W at 40° C
440 W at 25° C
MPCs
MPC1
MPC1E
MPC1 Q
MPC1E Q
MPC2
MPC2E
MPC2 Q
MPC2E Q
MPC2 EQ
MPC2E EQ
MX-MPC1-3D
MX-MPC1E-3D
165 W
With MICs and optics:
239 W at 55° C
227 W at 40° C
219 W at 25° C
MX-MPC1-3D-Q 175 W
MX-MPC1E-3D-Q With MICs and optics:
249 W at 55° C
237 W at 40° C
228 W at 25° C
MX-MPC2-3D
MX-MPC2E-3D
274 W
With MICs and optics:
348 W at 55° C
329 W at 40° C
315 W at 25° C
MX-MPC2-3D-Q 294 W
MX-MPC2E-3D-Q With MICs and optics:
368 W at 55° C
MX-MPC2-3D-EQ
MX-MPC2E-3D-EQ
347 W at 40° C
333 W at 25° C
Copyright © 2017, Juniper Networks, Inc.
173
MX960 3D Universal Edge Router Hardware Guide
Table 86: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
MPC2E P
MPC2E NG
MX-MPC2E-3D-P 294 W
With MICs and optics:
368 W at 55° C
347 W at 40° C
333 W at 25° C
MPC2E-3D-NG 474 W
With MICs and optics:
474 W at 55° C
417 W at 40° C
400 W at 25° C
MPC2E NG Q MPC2E-3D-NG-Q 529 W
With MICs and optics:
529 W at 55° C
460 W at 40° C
438 W at 25° C
MPC3E MX-MPC3E-3D
MPC3E NG MPC3E-3D-NG
440 W
With MICs and optics:
500 W at 55° C, two 40W MICs
485 W at 40° C, two CFP MICs with LR4 optics
473 W at 25° C, two CFP MICs with LR4 optics
534 W
With MICs and optics:
534 W at 55° C
485 W at 40° C
461 W at 25° C
MPC3E NG Q MPC3E-3D-NG-Q 583 W
With MICs and optics:
583 W at 55° C
532 W at 40° C
503 W at 25° C
174 Copyright © 2017, Juniper Networks, Inc.
Chapter 13: DC Power Requirements, Specifications, and Guidelines
Table 86: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
MICs
ATM MIC with
SFP
MPC4E-3D-2CGE-8XGE 610 W
With optics:
607 W at 55° C, with SFPP ZR and CFP LR4 optics
584 W at 40° C, with SFPP ZR and CFP LR4 optics
565 W at 25° C, with SFPP ZR and CFP LR4 optics
35 W
Gigabit
Ethernet MIC with SFP
MIC-3D-20-GE-SFP 37 W
10-Gigabit
Ethernet MIC with XFP
2-Port:
MIC-3D-2XGE-XFP
2-Port: 29 W
4-Port: 37 W
4-Port:
MIC-3D-4XGE-XFP
10-Gigabit
Ethernet MIC with SFP+
MIC3-3D-10XGE-SFPP 24.2 W at 55° C with SR and LR optics
29.8 W at 55° C with ER optics
29.8 W at 40° C with ZR optics
40-Gigabit
Ethernet MIC with QSFP+
MIC3-3D-2X40GE-QSFPP 18 W
100-Gigabit
Ethernet MIC with CFP
MIC3-3D-1X100GE-CFP 40 W
100-Gigabit
Ethernet MIC with CXP
MIC3-3D-1X100GE-CXP 20 W
100-Gigabit
DWDM OTN
MIC with CFP2
MIC3-100G-DWDM With optics:
91 W at 55° C
83 W at 25° C
Multiservices
MIC
MS-MIC-16G 60 W
Copyright © 2017, Juniper Networks, Inc.
175
MX960 3D Universal Edge Router Hardware Guide
Table 86: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
SONET/SDH
OC3/STM1
Multi-Rate
MIC
4-Port:
MIC-3D-4OC3OC12-1OC48
4-Port:
24 W at 55° C
22.75 W at 40° C
21.5 W at 25° C
8-Port:
MIC-3D-8OC3OC12-4OC48
8-Port:
29 W at 55° C
27.75 W at 40° C
26.5 W at 25° C
SONET/SDH
OC192/STM64
MIC with XFP
MIC-3D-1OC192-XFP 41 W at 55° C
38.5 W at 40° C
36 W at 25° C
Channelized
SONET/SDH
OC3/STM1
Multi-Rate
MIC
4-Port:
MIC-3D-4CHOC3-2CHOC12
4-Port:
41 W at 55° C
40 W at 40° C
39 W at 25° C
8-Port:
MIC-3D-8CHOC3-4CHOC12
8-Port:
52 W at 55° C
50.5 W at 40° C
49 W at 25° C
Tri-Rate MIC
DS3/E3 MIC
MIC-3D-40GE-TX 41 W
MIC-3D-8DS3-E3 36 W at 55° C
MIC-3D-8CHDS3-E3-B 35 W at 40° C
34 W at 25° C
Channelized
E1/T1 Circuit
Emulation MIC
MIC-3D-16CHE1-T1-CE 29.08 W at 55° C
27.84 W at 40° C
26.55 W at 25° C
176 Copyright © 2017, Juniper Networks, Inc.
Chapter 13: DC Power Requirements, Specifications, and Guidelines
Table 86: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
Channelized
OC3/STM1
(Multi-Rate)
Circuit
Emulation MIC with SFP
MIC-3D-4COC3-1COC12-CE 36.48 W at 55° C
35.04 W at 40° C
33.96 W at 25° C
DPCs
Gigabit
Ethernet DPC with SFP
DPC-R-40GE-SFP 335 W
Gigabit
Ethernet
Enhanced DPC with SFP
DPCE-R-40GE-SFP
DPCE-X-40GE-SFP
335 W
Gigabit
Ethernet
Enhanced
Queuing
Ethernet
Services DPC with SFP
(40-Port)
DPCE-R-Q-40GE-SFP 365 W
DPCE-X-Q-40GE-SFP
Gigabit
Ethernet
Enhanced
Queuing IP
Services DPCs with SFP
(20-Port)
DPCE-R-Q-20GE-SFP 200 W
10-Gigabit
Ethernet DPC with XFP
DPC-R-4XGE-XFP 310 W
10-Gigabit
Ethernet
Enhanced DPC with XFP
(2-Port)
DPCE-R-2XGE-XFP 175 W
10-Gigabit
Ethernet
Enhanced DPC with XFP
(4-Port)
DPCE-R-4XGE-XFP
DPCE-X-4XGE-XFP
310 W
Copyright © 2017, Juniper Networks, Inc.
177
MX960 3D Universal Edge Router Hardware Guide
Table 86: FRU Power Requirements
(continued)
Component Part Number Maximum Power Requirement
10-Gigabit
Ethernet
Enhanced
Queuing
Ethernet
Services DPC with XFP or
Enhanced
Queuing IP
Services DPC with XFP
DPCE-R-Q-4XGE-XFP 330 W
DPCE-X-Q-4XGE-XFP
Multi-Rate
Ethernet
Enhanced DPC with SFP and
XFP or
Multi-Rate
Ethernet
Enhanced
Ethernet
Services DPC with SFP and
XFP
DPCE-R-20GE-2XGE
DPCE-X-20GE-2XGE
333 W
Multi-Rate
Ethernet
Enhanced
Queuing IP
Services DPC with SFP and
XFP
DPCE-R-Q-20GE-2XGE 335 W
Tri-Rate
Enhanced DPC or Tri-Rate
Enhanced
Ethernet
Services DPC
DPCE-R-40GE-TX
DPCE-X-40GE-TX
320 W
265 W Multiservices
DPC
MS-DPC
FPCs
FPC Type 2
FPC Type 3
MX-FPC2
MX-FPC3
190 W (with PICs and optics)
265 W (with PICs and optics)
Related
Documentation
•
Electrical Specifications for the MX960 DC Power Supply on page 169
•
Electrical Specifications for the MX960 AC Power Supply on page 151
178 Copyright © 2017, Juniper Networks, Inc.
Chapter 13: DC Power Requirements, Specifications, and Guidelines
Calculating Power Requirements for MX960 Routers
The information in this topic helps you determine which power supplies are suitable for various configurations, as well as which power supplies are not suitable because output power is exceeded. You determine suitability by subtracting the total power draw from the maximum output of the power supplies. Afterward, the required input current is calculated. Finally, you calculate the thermal output. A sample configuration is provided in
.
We recommend that you provision power according to the maximum input current listed in the power supply electrical specifications (see
“Electrical Specifications for the MX960
and
“Electrical Specifications for the MX960 DC Power
Use the following procedures to calculate the power requirement:
1.
Calculate the power requirement.
2.
Evaluate the power budget.
3.
Calculate input power.
4.
Calculate thermal output (BTUs) for cooling requirements.
Copyright © 2017, Juniper Networks, Inc.
179
MX960 3D Universal Edge Router Hardware Guide
Both normal-capacity and high-capacity MX960 chassis with DC power supplies and
MX960 chassis with high-capacity AC power supplies are zoned. MX960 chassis with normal-capacity AC power supplies have one overall zone. Zoning means that certain components are powered by specific power supplies (see
for information on zoning). When calculating power requirements, be sure that there is adequate power for each zone.
Three AC power supplies are mandatory for MX960 chassis with normal-capacity AC power supplies.
Table 87: MX960 Zoning
Chassis Power Configuration Zone
Power Supply
(PEM) Components Receiving Power
MX960 DC (normal-capacity and high-capacity power supplies); MX960 AC (high-capacity power supplies)
Zone 0
MX960 DC (normal-capacity and high-capacity power supplies); MX960 AC (high-capacity power supplies)
Zone 1
PEM 0 or 2
PEM 1 or 3
•
•
•
Lower fan tray
DPC/MPC slots 6 through 11
SCB slots 1 through 2
•
•
•
Upper fan tray
DPC/MPC slots 0 through 5
SCB slot 0
The following sample configuration shows an MX960 chassis with:
• Four high-capacity AC power supplies (using two feeds for each power supply); two supplies are active, two are redundant
• Six 16 port 10 GbE MPC with SFP+ interfaces (slots 0 through 5)
• Two SCBs with two (redundant) RE-1800x2 routing engines (SCB slot 0 and SCB slot
1)
• SCB (SCB slot 6)
• Five 16 port 10 GbE MPC with SFP+ interfaces (slots 7 through 11)
• High-capacity cooling system (upper and lower fan trays)
NOTE: The high-capacity cooling system satisfies cooling requirements of MPCs, and must be used for proper cooling.
180 Copyright © 2017, Juniper Networks, Inc.
Chapter 13: DC Power Requirements, Specifications, and Guidelines
1.
Calculate the power requirements (usage) using the values in
“Power Requirements for an MX960 Router” on page 152
as shown in
Table 88: Sample Power Requirements for an MX960 Router
Chassis Component Part Number Power Requirement Zone
Base system MX960BASE-AC-HIGH 50 W
1
—
High-capacity cooling system FFANTRAY-MX960-HC 320 W * 2 = 640 W Zone 0 (lower fan tray) and Zone 1 (upper fan tray)
Zone 1
Zone 0
Zone 1
MPC - slots 0 through 5
MPC - slots 7 through 11
SCB 0
SCB 1
MPC-3D-16XGE-SFPP
MPC-3D-16XGE-SFPP
SCBE2-MX with
RE-S-1800X2-8G
SCBE2-MX with
RE-S-1800X2-8G
SCB 2 - slot 6 SCBE2-MX
MX960 normal-capacity AC (not zoned)
Zone 0 total output power
Zone 1 total output power
440 W * 6 = 2640 W
440 W * 5 = 2200 W
185 W
90 W
185 W
90 W
185 W
6265 W
3005 W
3260 W
1
Divided equally between zone 0 and zone 1.
Zone 0
Zone 0
2.
Evaluate the power budget, including the budget for each zone if applicable. In this step, we check the required power against the maximum output power of available power supply options.
lists the power supplies, their maximum output power, and unused power (or a power deficit).
Table 89: Calculating Power Budget
Power Supply
Maximum Output
Power of Power
Supply
Maximum Output
Power for System
Nonzoned
Unused Power
Zone 0 Unused
Power
1
Zone 1 Unused
Power
2
MX960 AC normal-capacity
1700 W 5100 W Power exceeded
(non-zoned;
5100 W - 6160 = power exceeded)
– –
Copyright © 2017, Juniper Networks, Inc.
181
MX960 3D Universal Edge Router Hardware Guide
Table 89: Calculating Power Budget
(continued)
Power Supply
Maximum Output
Power of Power
Supply
Maximum Output
Power for System
Nonzoned
Unused Power
Zone 0 Unused
Power
1
Zone 1 Unused
Power
2
MX960 AC high-capacity
MX960 DC normal-capacity
MX960 DC high-capacity
1700 W (one feed)
4100 W (two feeds)
3400 W (one feed)
8200 W (two feeds)
–
2800 W 5600 W –
1700 W (one feed)
4100 W (two feeds)
3400 W (one feed)
8200 W (two feeds)
–
Power exceeded Power exceeded
1165 W 875 W
Power exceeded Power exceeded
Power exceeded Power exceeded
1165 W 875 W
1
For this configuration, output power is 2935 W.
2
For this configuration, output power is 3225 W.
3.
Calculate input power. In this step, the input power requirements for the example configuration are calculated. To do this, divide the total output requirement by the efficiency of the power supply as shown in
.
NOTE: MX960 AC and MX960 DC normal-capacity power supplies are not included in the following table, because their power budget was exceeded in the sample configuration.
Table 90: Calculating Input Power
Power Supply
MX960 AC high-capacity
MX960 DC high-capacity
Power Supply Efficiency
1
~88 %
86 %
Input Power Requirement
2
3335 W
3
3413 W
3
1
These values are at full load and nominal voltage.
2
For this configuration, total power for zone 0 is 2935 W. The calculation method for zone 1 is the same as zone 0.
3
Zone 0 requirement.
4.
Calculate thermal output (BTUs). To calculate this, multiply the input power requirement (in watts) by 3.41 as shown in
182 Copyright © 2017, Juniper Networks, Inc.
Chapter 13: DC Power Requirements, Specifications, and Guidelines
Table 91: Calculating Thermal Output
Power Supply
MX960 AC high-capacity
MX960 DC high-capacity
Thermal Output (BTUs per hour)
3335 * 3.41 = 11,372 BTU/hr
1
3413 * 3.41 = 11,638 BTU/hr
1
1
Zone 0 output. The calculation method for zone 1 is the same as for zone 0.
Related
Documentation
•
Power Requirements for an MX960 Router on page 152
•
Electrical Specifications for the MX960 AC Power Supply on page 151
•
Electrical Specifications for the MX960 DC Power Supply on page 169
DC Power Circuit Breaker Requirements for the MX960 Router
If you plan to operate a maximally configured DC-powered router with normal capacity power suplies, we recommend that you provision at least 116 A (58 A per feed) @ –48
VDC (nominal) for the system. Use a customer site circuit breaker rated according to respective National Electrical Code and customer site internal standards to maintain proper level of protection for the current specified above.
If you plan to operate a maximally configured DC-powered router with high-capacity power supplies, we recommend that you provision at least 208 A (104 A per supply) @
–48 VDC (nominal) for the system. This is maximum current draw at –48 VDC when two power supplies are providing the power to the system and the redundant power supplies are not supplying power or not present. Use a customer site circuit breaker rated according to respective National Electrical Code and customer site internal standards to maintain proper level of protection for the current specified above.
If you plan to operate a DC-powered router at less than the maximum configuration, we recommend that you provision a circuit breaker according to respective National Electrical
Code and customer site internal standards to maintain proper level of protection for the current specified above or each DC power supply rated for at least 125% of the continuous current that the system draws at –48 VDC.
Related
Documentation
•
MX960 DC Power Supply on page 104
• MX960 DC Power Electrical Safety Guidelines
•
Electrical Specifications for the MX960 DC Power Supply on page 169
DC Power Source Cabling for the MX960 Router
shows a typical DC source cabling arrangement.
Copyright © 2017, Juniper Networks, Inc.
183
MX960 3D Universal Edge Router Hardware Guide
Figure 49: Typical DC Source Cabling to the Router
184
The DC power supplies in slots PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A , and the DC power supplies in slots PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B . This configuration provides the commonly deployed A/B feed redundancy for the system.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
WARNING: For field-wiring connections, use copper conductors only.
CAUTION: Power cords and cables must not block access to device components or drape where people could trip on them.
Related
Documentation
• General Electrical Safety Guidelines and Electrical Codes for Juniper Networks Devices
•
MX960 DC Power Supply on page 104
•
Connecting Power to a DC-Powered MX960 Router with Normal-Capacity Power
•
Replacing an MX960 DC Power Supply Cable on page 404
Copyright © 2017, Juniper Networks, Inc.
Chapter 13: DC Power Requirements, Specifications, and Guidelines
•
Connecting an MX960 DC Power Supply Cable on page 244
•
DC Power Cable Specifications for the MX960 Router on page 185
DC Power Cable Specifications for the MX960 Router
The accessory box shipped with the router includes the cable lugs that attach to the terminal studs of each power supply (see
Figure 50: DC Power Cable Lug
2.25
End view
0.55
0.28
2 holes
0.08
0.25
0.63
0.37
4 AWG conductor
Crimp area
All measurements in inches
CAUTION: Before router installation begins, a licensed electrician must attach a cable lug to the grounding and power cables that you supply. A cable with an incorrectly attached lug can damage the router.
WARNING: The Router is a pluggable type A equipment installed in restricted access location. It has a separate protective earthing terminal (Metric [–M6] and English [–¼-20] screw ground lugs) provided on the chassis in addition to the grounding pin of the power supply cord. This separate protective earth terminal must be permanently connected to earth.
summarizes the specifications for the power cables, which you must supply.
Table 92: DC Power Cable Specifications
Cable Type Quantity and Specification
Power Eight 4-AWG (13.3 mm
2
), minimum 60°C wire, or as required by the local code
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
Copyright © 2017, Juniper Networks, Inc.
185
MX960 3D Universal Edge Router Hardware Guide
Related
Documentation
•
MX960 DC Power Supply on page 104
• MX960 DC Power Electrical Safety Guidelines
•
DC Power Source Cabling for the MX960 Router on page 183
•
Connecting an MX960 DC Power Supply Cable on page 244
186 Copyright © 2017, Juniper Networks, Inc.
PART 3
Initial Installation and Configuration
•
Unpacking the MX960 Router on page 189
•
Installing the Mounting Hardware on page 195
•
Installing the MX960 Router on page 203
•
Connecting the MX960 Router to Power on page 225
•
Connecting the MX960 Router to the Network on page 247
•
Initially Configuring the MX960 Router on page 257
Copyright © 2017, Juniper Networks, Inc.
187
MX960 3D Universal Edge Router Hardware Guide
188 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 14
Unpacking the MX960 Router
•
Tools and Parts Required to Unpack the MX960 Router on page 189
•
Unpacking the MX960 Router on page 189
•
Verifying the MX960 Parts Received on page 191
Tools and Parts Required to Unpack the MX960 Router
To unpack the router and prepare for installation, you need the following tools:
• Phillips (+) screwdriver, number 2
• 1/2-in. or 13-mm open-end or socket wrench to remove bracket bolts from the shipping pallet
• Blank panels to cover any slots not occupied by a component
Related
Documentation
•
Unpacking the MX960 Router on page 189
•
Verifying the MX960 Parts Received on page 191
•
MX960 Router Overview on page 3
Unpacking the MX960 Router
The router is shipped in a wooden crate. A wooden pallet forms the base of the crate.
The router chassis is bolted to this pallet. Quick Start installation instructions and a cardboard accessory box are also included in the shipping crate.
The shipping container measures 21 in. (53.3 cm) high, 23.5 in. (60.0 cm) wide, and
32.5 in. (82.5 cm) deep. The total weight of the container containing the router and accessories can range from 93 lb (42.2 kg) to 169 lb (76.7 kg).
NOTE: The router is maximally protected inside the shipping crate. Do not unpack it until you are ready to begin installation.
Copyright © 2017, Juniper Networks, Inc.
189
MX960 3D Universal Edge Router Hardware Guide
To unpack the router (see
):
1.
Move the shipping crate to a staging area as close to the installation site as possible, where you have enough room to remove the components from the chassis. While the chassis is bolted to the pallet, you can use a forklift or pallet jack to move it.
2.
Position the shipping crate with the arrows pointing up.
3.
Open all the latches on the shipping crate.
4.
Remove the front door of the shipping crate cover and set it aside.
5.
Slide the remainder of the shipping crate cover off the pallet.
6.
Remove the foam covering the top of the router.
7.
Remove the accessory box and the Quick Start installation instructions.
8.
Verify the parts received against the lists.
9.
Remove the vapor corrosion inhibitor (VCI) packs attached to the pallet, being careful not to break the VCI packs open.
10.
To remove the brackets holding the chassis on the pallet, use a 1/2-in. socket wrench and a number 2 Phillips screwdriver to remove the bolts and screws from the brackets.
11.
Store the brackets and bolts inside the accessory box.
12.
Save the shipping crate cover, pallet, and packing materials in case you need to move or ship the router at a later time.
Figure 51: Contents of the Shipping Crate
190 Copyright © 2017, Juniper Networks, Inc.
Chapter 14: Unpacking the MX960 Router
Related
Documentation
•
Tools and Parts Required to Unpack the MX960 Router on page 189
•
Verifying the MX960 Parts Received on page 191
•
Installing the MX960 Router Using a Mechanical Lift on page 214
Verifying the MX960 Parts Received
A packing list is included in each shipment. Check the parts in the shipment against the items on the packing list. The packing list specifies the part numbers and descriptions of each part in your order.
If any part is missing, contact a customer service representative.
A fully configured router contains the router chassis with installed components, listed in
Table 93 on page 191 , and an accessory box, which contains the parts listed in
. The parts shipped with your router can vary depending on the configuration you ordered.
Table 93: Parts List for a Fully Configured MX960 Router
Component Quantity
Chassis, including midplane, craft interface, front-mounting flanges, and center-mounting brackets
1
DPCs
FPCs
MPCs
Up to 12
Up to 6
Up to 12
MICs
PICs
Routing Engines
SCBs
Power supplies
Fan trays
Air filter
Air filter tray
Quick start installation instructions
Large mounting shelf
1
1
1
1
Up to 24
Up to 12
1 or 2
Up to 3
Up to 4
2
Copyright © 2017, Juniper Networks, Inc.
191
MX960 3D Universal Edge Router Hardware Guide
192
Table 93: Parts List for a Fully Configured MX960 Router
(continued)
Component Quantity
Small mounting shelf
Blank panels for slots without components installed
1
One blank panel for each slot not occupied by a component
Table 94: Accessory Box Parts List
Part Quantity
Screws to mount chassis
DC power terminal Lugs, 4-AWG
RJ-45 cable, with RJ-45 Jack to Female DB-9, to connect the router through the serial port
1
Terminal block plug, 3 pole, 5.08 mm spacing, 12A, to connect the router alarms
2
14
8
Label, accessories contents, MX960
USB flash drive with Junos
Read me first document
Affidavit for T1 connection
Juniper Networks Product Warranty
End User License Agreement
Document sleeve
3" x 5" pink bag
9" x 12" pink bag, ESD
Accessory Box, 19 x 12 x 3"
Ethernet cable, RJ-45/RJ-45, 4-pair stranded UTP,
Category 5E, 15'
ESD wrist strap with cable
1
1
1
1
1
1
2
1
1
2
1
1
Related
Documentation
•
Tools and Parts Required to Unpack the MX960 Router on page 189
•
Unpacking the MX960 Router on page 189
Copyright © 2017, Juniper Networks, Inc.
•
MX960 Router Overview on page 3
Chapter 14: Unpacking the MX960 Router
Copyright © 2017, Juniper Networks, Inc.
193
MX960 3D Universal Edge Router Hardware Guide
194 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 15
Installing the Mounting Hardware
•
Installing the MX960 Mounting Hardware for a Four-Post Rack or Cabinet on page 195
•
Installing the MX960 Mounting Hardware for Front-Mounting in an Open-Frame
•
Installing the MX960 Mounting Hardware for Center-Mounting in an Open-Frame
Installing the MX960 Mounting Hardware for a Four-Post Rack or Cabinet
Before installing the router in a four-post rack or cabinet, install the large mounting shelf, followed by the small mounting shelf. You must also remove the mounting brackets from the chassis.
specifies the holes in which you insert cage nuts, if needed, and screws to install the mounting hardware required in a four-post or cabinet rack (an X indicates a mounting hole location). The hole distances are relative to one of the standard
U divisions on the rack. The bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
Table 95: Four-Post Rack or Cabinet Mounting Hole Locations
Hole Distance Above U Division
Large
Shelf
Small
Shelf
3 1.51 in. (3.8 cm) 0.86 U X
2
1
0.88 in. (2.2 cm)
0.25 in. (0.6 cm)
0.50 U
0.14 U
X X
X
To install the mounting shelves (see
1.
On the front rack rails, install cage nuts, if needed, in the holes specified in
for the large shelf and the spacer bars.
2.
On the front of each front rack rail, partially insert a mounting screw into the hole containing the lowest cage nut.
Copyright © 2017, Juniper Networks, Inc.
195
MX960 3D Universal Edge Router Hardware Guide
3.
Install the large shelf on the front rack rails. Rest the bottom slot of each flange of the large shelf on a mounting screw.
4.
Partially insert a mounting screw into the top hole in each flange of the large shelf.
5.
Tighten all the screws completely.
6.
On the rear rack rails, install cage nuts, if needed, in the holes specified in
for the small shelf.
7.
On the back of each rear rack rail, partially insert a mounting screw into the hole containing the lowest cage nut.
8.
Install the small shelf on the back rack rails. Rest the bottom slot of each flange of the small shelf on a mounting screw. The small shelf installs on the back of the rear rails, extending toward the center of the rack. The bottom of the small shelf should align with the bottom of the large shelf.
9.
Partially insert screws into the open holes in the flanges of the small shelf.
10.
Tighten all the screws completely.
196 Copyright © 2017, Juniper Networks, Inc.
Chapter 15: Installing the Mounting Hardware
Figure 52: Installing the Mounting Hardware for a Four-Post Rack or
Cabinet
After the mounting hardware is installed, proceed to
“Installing the MX960 Router Using a Mechanical Lift” on page 214
.
Related
Documentation
•
Installing the MX960 Mounting Hardware for Center-Mounting in an Open-Frame Rack on page 199
•
Installing the MX960 Mounting Hardware for Front-Mounting in an Open-Frame Rack on page 197
•
MX960 Rack-Mounting Hardware on page 14
Installing the MX960 Mounting Hardware for Front-Mounting in an Open-Frame Rack
Before front-mounting the router in an open-frame rack, install the large mounting shelf on the rack, and remove the mounting brackets from the chassis. The small mounting shelf is not needed.
specifies the holes in which you insert screws to install the mounting hardware in an open-frame rack (an X indicates a mounting hole location). The hole distances are relative to one of the standard U divisions on the rack. For reference, the bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
Copyright © 2017, Juniper Networks, Inc.
197
MX960 3D Universal Edge Router Hardware Guide
3
2
1
18
15
12
Table 96: Mounting Hardware Hole Locations for Front-Mounting in an
Open-Frame Rack
Hole Distance Above U Division Large Shelf
X 30
27
17.26 in. (43.8 cm) 9.86 U
15.51 in. (39.4 cm) 8.86 U X
X 24
21
13.76 in. (34.9 cm) 7.86 U
12.01 in. (30.5 cm) 6.86 U X
X 10.26 in. (26.0 cm) 5.86 U
8.51 in. (21.6 cm)
6.76 in. (17.1 cm)
4.86 U
3.86 U
X
X
X 9
6
5.01 in. (12.7 cm)
3.26 in. (8.3 cm)
2.86 U
1.86 U X
X 1.51 in. (3.8 cm)
0.88 in. (2.2 cm)
0.25 in. (0.6 cm)
0.86 U
0.50 U
0.14 U
X
To install the large mounting shelf (see
1.
On the rear of each rack rail, install cage nuts, if needed, in the holes specified in
for the large shelf.
2.
Partially insert a mounting screw into the highest hole specified in
.
3.
Hange the shelf over the mounting screws using the keyhole slots located near the top of the large shelf flanges.
4.
Partially insert screws into the open holes in the flanges of the large shelf.
5.
Tighten all the screws completely.
198 Copyright © 2017, Juniper Networks, Inc.
Chapter 15: Installing the Mounting Hardware
Figure 53: Installing the Mounting Hardware for Front-Mounting in an
Open-Frame Rack
Open-frame rack
Large mounting shelf
After the mounting hardware is installed, proceed to
“Installing the MX960 Router Using a Mechanical Lift” on page 214
.
Related
Documentation
•
Installing the MX960 Mounting Hardware for a Four-Post Rack or Cabinet on page 195
•
Installing the MX960 Mounting Hardware for Center-Mounting in an Open-Frame Rack on page 199
•
MX960 Rack-Mounting Hardware on page 14
Installing the MX960 Mounting Hardware for Center-Mounting in an Open-Frame Rack
Before center-mounting the router in an open-frame rack, you must install the large mounting shelf on the rack. The small mounting shelf is not needed.
specifies the holes in which you insert screws to install the mounting hardware in an open-frame rack (an X indicates a mounting hole location). The hole distances are relative to one of the standard U divisions on the rack. For reference, the bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
Copyright © 2017, Juniper Networks, Inc.
199
MX960 3D Universal Edge Router Hardware Guide
3
2
1
18
15
12
Table 97: Mounting Hardware Hole Locations for Center-Mounting in an
Open-Frame Rack
Hole Distance Above U Division Large Shelf
X 30
27
17.26 in. (43.8 cm) 9.86 U
15.51 in. (39.4 cm) 8.86 U X
X 24
21
13.76 in. (34.9 cm) 7.86 U
12.01 in. (30.5 cm) 6.86 U X
X 10.26 in. (26.0 cm) 5.86 U
8.51 in. (21.6 cm)
6.76 in. (17.1 cm)
4.86 U
3.86 U
X
X
X 9
6
5.01 in. (12.7 cm)
3.26 in. (8.3 cm)
2.86 U
1.86 U X
X 1.51 in. (3.8 cm)
0.88 in. (2.2 cm)
0.25 in. (0.6 cm)
0.86 U
0.50 U
0.14 U
X
To install the large mounting shelf (see
1.
On the rear of each rack rail, partially insert a mounting screw into the highest hole specified in
for the large shelf.
2.
Install the large shelf on the rack. Hang the shelf over the mounting screws using the keyhole slots located near the top of the large shelf flanges.
3.
Partially insert screws into the open holes in the flanges of the large shelf.
4.
Tighten all the screws completely.
200 Copyright © 2017, Juniper Networks, Inc.
Chapter 15: Installing the Mounting Hardware
Figure 54: Installing the Mounting Hardware for Center-Mounting in an
Open-Frame Rack
Open-frame rack
Large mounting shelf
After the mounting hardware is installed, proceed to
“Installing the MX960 Router Using a Mechanical Lift” on page 214
.
Related
Documentation
•
Installing the MX960 Mounting Hardware for a Four-Post Rack or Cabinet on page 195
•
Installing the MX960 Mounting Hardware for Front-Mounting in an Open-Frame Rack on page 197
•
MX960 Rack-Mounting Hardware on page 14
Copyright © 2017, Juniper Networks, Inc.
201
MX960 3D Universal Edge Router Hardware Guide
202 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 16
Installing the MX960 Router
•
Installing an MX960 Router Overview on page 203
•
Removing Components from the MX960 Router Chassis Before Installing It with a
•
Tools Required to Install the MX960 Router with a Mechanical Lift on page 213
•
Installing the MX960 Router Using a Mechanical Lift on page 214
•
Reinstalling Components in the MX960 Chassis After Installing It with a Lift on page 216
Installing an MX960 Router Overview
To install the MX960 router:
1.
Prepare your installation site.
See
“MX960 Site Preparation Checklist” on page 124 .
2.
Review the safety guidelines.
• General Safety Guidelines for Juniper Networks Devices
• General Safety Warnings for Juniper Networks Devices
3.
Unpack the router and verify the parts.
a.
Unpacking the MX960 Router on page 189
b.
Verifying the MX960 Parts Received on page 191
4.
Install the mounting hardware.
•
Installing the MX960 Mounting Hardware for a Four-Post Rack or Cabinet on page 195
•
Installing the MX960 Mounting Hardware for Front-Mounting in an Open-Frame
•
Installing the MX960 Mounting Hardware for Center-Mounting in an Open-Frame
5.
Lift the router on to the rack. Because of the weight of the router, we recommend that you use a mechanical lift.
Copyright © 2017, Juniper Networks, Inc.
203
MX960 3D Universal Edge Router Hardware Guide
See
“Installing the MX960 Router Using a Mechanical Lift” on page 214 .
6.
Connect cables to the network and external devices.
See
“Connecting the MX960 Router to Management and Alarm Devices” on page 247 .
7.
Connect the grounding cable
See
“Grounding the MX960 Router” on page 226 .
8.
Connect the AC power cord or DC power cables:
•
Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power
•
Connecting Power to a DC-Powered MX960 Router with Normal-Capacity Power
9.
Power on the router:
•
Powering On an AC-Powered MX960 Router with Normal Capacity Power Supplies on page 232
•
Powering On a DC-Powered MX960 Router with Normal Capacity Power Supplies on page 240
10.
Perform the initial system configuration.
See
“Initially Configuring the MX960 Router” on page 257
.
Related
Documentation
•
MX960 Chassis Description on page 9
•
Routine Maintenance Procedures for the MX960 Router on page 443
•
Troubleshooting Resources for MX960 Routers on page 487
Removing Components from the MX960 Router Chassis Before Installing It with a Lift
Before installing the router with a lift, you must first remove components from the chassis, and reinstall the components the router is installed in the rack. With components removed, the chassis weighs approximately 150 lb (68.04 kg).
1.
Removing the Power Supplies Before Installing an MX960 Router with a Lift on page 205
2.
Removing the Standard Cable Manager Before Installing an MX960 Router with a
3.
Removing the Fan Trays Before Installing an MX960 Router with a Lift on page 207
4.
Removing the SCBs Before Installing an MX960 Router with a Lift on page 209
5.
Removing the DPCs Before Installing an MX960 Router with a Lift on page 210
6.
Removing the FPCs Before Installing the MX960 Router with a Lift on page 212
204 Copyright © 2017, Juniper Networks, Inc.
Chapter 16: Installing the MX960 Router
Removing the Power Supplies Before Installing an MX960 Router with a Lift
Remove the leftmost power supply first and then work your way to the right. To remove the AC or DC power supplies for each power supply (see
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
On an AC-powered router, move the AC input switch in the chassis above each power supply to the off ( O ) position. On a DC-powered router, move the DC circuit breaker on each power supply faceplate to the off ( O ) position.
We recommend this even though the power supplies are not connected to power sources.
3.
While grasping the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops.
4.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
5.
Pull the power supply straight out of the chassis.
WARNING: Do not touch the power connector on the top of the power supply. It can contain dangerous voltages.
Copyright © 2017, Juniper Networks, Inc.
205
MX960 3D Universal Edge Router Hardware Guide
Figure 55: Removing a Power Supply Before Installing the MX960 Router
Removing the Standard Cable Manager Before Installing an MX960 Router with a Lift
To remove the standard cable manager (see
):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Using a 7/16-in. (11 mm) nut driver, unscrew the nuts on the corners of the standard cable manager.
3.
Grasp the bottom of the standard cable manager, and pull it straight out from the studs on the front of the chassis.
206 Copyright © 2017, Juniper Networks, Inc.
Chapter 16: Installing the MX960 Router
Figure 56: Removing the Standard Cable Manager
Removing the Fan Trays Before Installing an MX960 Router with a Lift
To remove the upper or lower fan tray (see
and
, which illustrate the upper and lower fan trays):
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
2.
Loosen the captive screw on each side of the fan tray faceplate.
3.
Grasp both sides of the fan tray, and pull it out approximately 1 to 3 inches.
4.
Press on the two latches located on the inside of the fan tray to release the fan tray from the chassis.
5.
Place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Copyright © 2017, Juniper Networks, Inc.
207
MX960 3D Universal Edge Router Hardware Guide
Figure 57: Removing an Upper Fan Tray
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
208 Copyright © 2017, Juniper Networks, Inc.
Chapter 16: Installing the MX960 Router
Figure 58: Removing a Lower Fan Tray
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
YELL
M
OK FAIL
7
ONLINE
ACO/LT
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK
FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Removing the SCBs Before Installing an MX960 Router with a Lift
To remove the SCBs (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Rotate the ejector handles simultaneously counterclockwise to unseat the SCB.
4.
Grasp the ejector handles, and slide the SCB about halfway out of the chassis.
5.
Place one hand underneath the SCB to support it, and slide it completely out of the chassis. Place it on the antistatic mat.
Copyright © 2017, Juniper Networks, Inc.
209
MX960 3D Universal Edge Router Hardware Guide
CAUTION: Do not stack hardware components on one another after you remove them. Place each component on an antistatic mat resting on a stable, flat surface.
6.
Repeat the procedure for each SCB.
Figure 59: Removing an SCB
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK
FAIL OK
FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK
FAIL
5
ONLINE
RE0
OK
FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO NC
C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Removing the DPCs Before Installing an MX960 Router with a Lift
To remove a DPC (see
1.
Have ready an antistatic mat for the DPC. Also have ready rubber safety caps for each
DPC using an optical interface on the DPC that you are removing.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Simultaneously turn both the ejector handles counterclockwise to unseat the DPC.
210 Copyright © 2017, Juniper Networks, Inc.
Chapter 16: Installing the MX960 Router
4.
Grasp the handles, and slide the DPC straight out of the card cage halfway.
5.
Place one hand around the front of the DPC and the other hand under it to support it.
Slide the DPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the DPC is concentrated in the back end. Be prepared to accept the full weight—up to 13.1 lb (5.9 kg)—as you slide the
DPC out of the chassis.
When the DPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
Do not stack DPC on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
Figure 60: Removing a DPC
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK
FAIL OK
FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK
FAIL
5
ONLINE
OK
RE0
FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO NC
OK
FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
OK/FAIL
2/0 2/5
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1/0 1/5
3/0 3/5
Copyright © 2017, Juniper Networks, Inc.
211
MX960 3D Universal Edge Router Hardware Guide
Removing the FPCs Before Installing the MX960 Router with a Lift
To remove an FPC (see
):
1.
Have ready an antistatic mat for the FPC. Also have ready rubber safety caps for each
PIC using an optical interface on the PIC that you are removing.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Simultaneously turn both the ejector handles counterclockwise to unseat the FPC.
4.
Grasp the handles, and slide the FPC straight out of the card cage halfway.
5.
Place one hand around the front of the FPC and the other hand under it to support it.
Slide the FPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the FPC is concentrated in the back end. Be prepared to accept the full weight—up to 18 lb (8.2 kg)—as you slide the
FPC out of the chassis.
When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
212 Copyright © 2017, Juniper Networks, Inc.
Figure 61: Removing an FPC
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC
OK
FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
OK/FAIL
2/0 2/5
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1/0 1/5
3/0 3/5
Chapter 16: Installing the MX960 Router
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
MX960 Site Preparation Checklist on page 124
•
Tools Required to Install the MX960 Router with a Mechanical Lift on page 213
•
Installing the MX960 Router Using a Mechanical Lift on page 214
•
Reinstalling Components in the MX960 Chassis After Installing It with a Lift on page 216
Tools Required to Install the MX960 Router with a Mechanical Lift
To install the router, you need the following tools:
• Mechanical lift
• Phillips (+) screwdriver, number 2
• 7/16-in. (11 mm) nut driver
• ESD grounding wrist strap
Related
Documentation
•
MX960 Site Preparation Checklist on page 124
Copyright © 2017, Juniper Networks, Inc.
213
MX960 3D Universal Edge Router Hardware Guide
•
Removing Components from the MX960 Router Chassis Before Installing It with a Lift on page 204
•
Installing the MX960 Router Using a Mechanical Lift on page 214
•
Reinstalling Components in the MX960 Chassis After Installing It with a Lift on page 216
Installing the MX960 Router Using a Mechanical Lift
Because of the router's size and weight—up to 350 lb (158.8 kg) depending on the configuration—you must use mechanical lift to install the router.
CAUTION: Before front mounting the router in a rack, have a qualified technician verify that the rack is strong enough to support the router's weight and is adequately supported at the installation site.
To install the router using a lift (see
1.
Ensure that the rack is in its permanent location and is secured to the building. Ensure that the installation site allows adequate clearance for both airflow and maintenance.
2.
Load the router onto the lift, making sure it rests securely on the lift platform.
3.
Using the lift, position the router in front of the rack or cabinet, centering it in front of the mounting shelf.
4.
Lift the chassis approximately 0.75 in. above the surface of the mounting shelf and position it as close as possible to the shelf.
5.
Carefully slide the router onto the mounting shelf so that the bottom of the chassis and the mounting shelf overlap by approximately two inches.
6.
Slide the router onto the mounting shelves until the mounting brackets or front-mounting flanges contact the rack rails. The shelves ensure that the holes in the mounting brackets and the front-mounting flanges of the chassis align with the holes in the rack rails.
7.
Move the lift away from the rack.
8.
To install the router in an open-frame rack, install a mounting screw into each of the open mounting holes aligned with the rack, starting from the bottom.
9.
Visually inspect the alignment of the router. To verify that the router is installed properly in the rack, verify that all the mounting screws on one side of the rack are aligned with the mounting screws on the opposite side and the router is level.
214 Copyright © 2017, Juniper Networks, Inc.
Chapter 16: Installing the MX960 Router
Figure 62: Installing the MX960 Router in the Rack
NOTE: This illustration depicts the router being installed in an open-frame rack.
Related
Documentation
•
MX960 Site Preparation Checklist on page 124
•
Tools Required to Install the MX960 Router with a Mechanical Lift on page 213
•
Removing Components from the MX960 Router Chassis Before Installing It with a Lift on page 204
•
Reinstalling Components in the MX960 Chassis After Installing It with a Lift on page 216
Copyright © 2017, Juniper Networks, Inc.
215
MX960 3D Universal Edge Router Hardware Guide
Reinstalling Components in the MX960 Chassis After Installing It with a Lift
After the router is installed in the rack, reinstall the removed components before booting and configuring the router. You reinstall components first in the rear of the chassis, and then in the front:
1.
Reinstalling the Power Supplies After Installing the MX960 Router with a
2.
Reinstalling the Fan Trays After Installing the MX960 Router with a Lift on page 217
3.
Reinstalling the SCBs After Installing the MX960 Router with a Lift on page 219
4.
Reinstalling the DPCs After Installing the MX960 Router with a Lift on page 220
5.
Reinstalling the FPCs After Installing the MX960 Router with a Lift on page 222
6.
Reinstalling the Standard Cable Manager After Installing an MX960 Router with a
Reinstalling the Power Supplies After Installing the MX960 Router with a Lift
Reinstall the rightmost power supply first and then work your way to the left. To reinstall the AC or DC power supplies, follow this procedure for each power supply (see
, which shows the installation of the DC power supplies):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
For an AC-powered router, move the AC input switch in the chassis above the power supply slot to the off ( O ) position. For a DC-powered router, move the DC circuit breaker on the power supply to the off ( O ) position.
We recommend this even though the power supplies are not connected to power sources.
3.
Ensure that the release lever below the empty power supply slot is locked in the counterclockwise position (see
).
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
4.
Using both hands, slide the power supply straight into the chassis until the power supply is fully seated in the chassis slot. The power supply faceplate should be flush with any adjacent power supply faceplates.
The small tab on the metal housing that is controlled by the release lever must be inside of the corresponding slot at the bottom of the power supply. This tab is used to pull the power supply down in the chassis slot, prior to removing the power supply.
216 Copyright © 2017, Juniper Networks, Inc.
Chapter 16: Installing the MX960 Router
5.
While firmly pushing the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever clockwise until it stops.
6.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
Figure 63: Reinstalling a Power Supply
Reinstalling the Fan Trays After Installing the MX960 Router with a Lift
To reinstall the fan trays (see
and
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Grasp the fan tray on each side, and insert it straight into the chassis. Note the correct orientation by the "this side up" label on the top surface of the fan tray.
Copyright © 2017, Juniper Networks, Inc.
217
MX960 3D Universal Edge Router Hardware Guide
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
4.
Lower the standard cable manager back into position, if necessary.
Figure 64: Installing an Upper Fan Tray
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK
FAIL
0
ONLINE
1
ONLINE
OK
FAIL
2 6
ONLINE
ACO/LT
OK
FAIL
7
ONLINE
OK
FAIL
NC C
NO NC
OK FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK
FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
218 Copyright © 2017, Juniper Networks, Inc.
Figure 65: Installing a Lower Rear Fan Tray
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK
FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO NC
C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Chapter 16: Installing the MX960 Router
Reinstalling the SCBs After Installing the MX960 Router with a Lift
To reinstall an SCB (see
):
CAUTION: Before removing or replacing an SCB, ensure that the ejector handles are stored horizontally and pressed toward the center of the SCB.
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Carefully align the sides of the SCB with the guides inside the chassis.
3.
Slide the SCB into the chassis until you feel resistance, carefully ensuring that it is correctly aligned.
Copyright © 2017, Juniper Networks, Inc.
219
MX960 3D Universal Edge Router Hardware Guide
4.
Grasp both ejector handles, and rotate them simultaneously clockwise until the SCB is fully seated.
5.
Place the ejector handles in their proper position, vertically and toward the center of the board. To avoid blocking the visibility of the LEDs position the ejectors over the
PARK icon.
Figure 66: Reinstalling an SCB
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK
FAIL OK
FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK
FAIL
5
ONLINE
RE0
OK
FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK FAIL
NC C NO NC
C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK
FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Reinstalling the DPCs After Installing the MX960 Router with a Lift
To reinstall a DPC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Take each DPC to be installed out of its electrostatic bag, and identify the slot on the
DPC where it will be connected.
3.
Verify that each fiber-optic DPC has a rubber safety cap covering the transceiver. If it does not, cover the transceiver with a safety cap.
220 Copyright © 2017, Juniper Networks, Inc.
Chapter 16: Installing the MX960 Router
4.
Locate the slot in the DPC card cage in which you plan to install the DPC.
5.
Ensure that the DPC is right-side up, with the text on the faceplate of the DPC facing upward.
6.
Lift the DPC into place, and carefully align first the bottom, then the top of the DPC with the guides inside the card cage.
7.
Slide the DPC all the way into the card cage until you feel resistance.
8.
Grasp both ejector handles, and rotate them simultaneously clockwise until the DPC is fully seated.
Figure 67: Installing a DPC
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK
FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK
FAIL
5
ONLINE
RE0
OK
FAIL
MASTER
ONLINE
OFFLINE
RE1
OK
FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELL
M
OK FAIL
NC
C NO NC C
NO
OK FAIL
8
ONLINE
9
ONLINE
OK
FAIL
10
ONLINE
OK FAIL
11
ONLINE
0/0 0/5
OK/FAIL
2/0 2/5
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1/0 1/5
3/0 3/5
Copyright © 2017, Juniper Networks, Inc.
221
MX960 3D Universal Edge Router Hardware Guide
Reinstalling the FPCs After Installing the MX960 Router with a Lift
To reinstall an FPC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place the FPC on an antistatic mat, or remove it from its electrostatic bag.
3.
Identify the two DPC slots on the router where the FPC will be installed.
4.
Verify that each fiber-optic transceiver on the PIC is covered by a rubber safety cap.
If it does not, cover the transceiver with a safety cap.
5.
Orient the FPC so that the faceplate faces you.
6.
Lift the FPC into place, and carefully align the sides of the FPC with the guides inside the card cage.
7.
Slide the FPC all the way into the card cage until you feel resistance.
8.
Grasp both ejector handles, and rotate them clockwise simultaneously until the FPC is fully seated.
222 Copyright © 2017, Juniper Networks, Inc.
Figure 68: Reinstalling an FPC
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ALAR M
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Chapter 16: Installing the MX960 Router
Reinstalling the Standard Cable Manager After Installing an MX960 Router with a Lift
To reinstall the standard cable manager (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Position the cable manager on the studs on the lower front of the chassis.
3.
Insert the nuts on the corners in the cable manager onto the studs on the chassis.
4.
Using a 7/16-in. (11 mm) nut driver, tighten the nuts securely.
Copyright © 2017, Juniper Networks, Inc.
223
MX960 3D Universal Edge Router Hardware Guide
Figure 69: Reinstalling the Cable Manager
224
Related
Documentation
•
MX960 Site Preparation Checklist on page 124
•
Tools Required to Install the MX960 Router with a Mechanical Lift on page 213
•
Removing Components from the MX960 Router Chassis Before Installing It with a Lift on page 204
•
Installing the MX960 Router Using a Mechanical Lift on page 214
Copyright © 2017, Juniper Networks, Inc.
CHAPTER 17
Connecting the MX960 Router to Power
•
Tools and Parts Required for MX960 Router Grounding and Power
•
Grounding the MX960 Router on page 226
•
Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power
•
Connecting Power to an AC-Powered MX960 Router with High-Capacity Power
•
Powering On an AC-Powered MX960 Router with Normal Capacity Power
•
Connecting Power to a DC-Powered MX960 Router with Normal-Capacity Power
•
Connecting Power to a DC-Powered MX960 Router with High-Capacity Power
•
Powering On a DC-Powered MX960 Router with Normal Capacity Power
•
Powering Off the MX960 Router on page 242
•
Connecting an MX960 AC Power Supply Cord on page 243
•
Connecting an MX960 DC Power Supply Cable on page 244
Tools and Parts Required for MX960 Router Grounding and Power Connections
To ground and provide power to the router, you need the following tools and parts:
• Phillips (+) screwdrivers, numbers 1 and 2
• 2.5-mm flat-blade (–) screwdriver
• 7/16-in. (11 mm) hexagonal-head external drive socket wrench, or nut driver, with a torque range between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) tightening torque, for tightening nuts to terminal studs on each power supply on a DC-powered router.
• Wire cutters
• Electrostatic discharge (ESD) grounding wrist strap
Copyright © 2017, Juniper Networks, Inc.
225
MX960 3D Universal Edge Router Hardware Guide
CAUTION: The maximum torque rating of the terminal studs on the DC power supply is 58 lb-in. (6.5 Nm). The terminal studs may be damaged if excessive torque is applied. Use only a torque-controlled driver or socket wrench to tighten nuts on the DC power supply terminal studs. Use an appropriately-sized driver or socket wrench. Ensure that the driver is undamaged and properly calibrated and that you have been trained in its use. You may wish to use a driver that is designed to prevent overtorque when the preset torque level is achieved.
Related
Documentation
•
Grounding the MX960 Router on page 226
•
MX960 Router Grounding Specifications on page 145
•
Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power
•
Connecting Power to a DC-Powered MX960 Router with Normal-Capacity Power
Grounding the MX960 Router
You ground the router by connecting a grounding cable to earth ground and then attaching it to the chassis grounding points using two screws. You must provide the grounding cables (the cable lugs are supplied with the router).
1.
Verify that a licensed electrician has attached the cable lug provided with the router to the grounding cable.
2.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an approved site ESD grounding point. See the instructions for your site.
3.
Ensure that all grounding surfaces are clean and brought to a bright finish before grounding connections are made.
4.
Connect the grounding cable to a proper earth ground.
5.
Detach the ESD grounding strap from the site ESD grounding point.
6.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
7.
Place the grounding cable lug over the grounding points on the rear of the chassis.
The left pair is sized for M6 screws, and the right pair is sized for UNC 1/4-20 screws.
226 Copyright © 2017, Juniper Networks, Inc.
Chapter 17: Connecting the MX960 Router to Power
8.
Secure the grounding cable lug to the grounding points, first with the washers, then with the screws.
9.
Dress the grounding cable and verify that it does not touch or block access to router components, and that it does not drape where people could trip on it.
Related
Documentation
•
MX960 Router Grounding Specifications on page 145
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power
•
Connecting Power to a DC-Powered MX960 Router with Normal-Capacity Power
Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power
Supplies
CAUTION: Do not mix AC and DC power supplies within the same router.
Damage to the router might occur.
The AC appliance inlets are located in the chassis directly above the power supplies.
To connect the AC power cords to the router (see
1.
Locate the power cords shipped with the router, which should have a plug appropriate for your geographical location.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Move the AC input switch, which is to the right of the appliance inlet on the chassis, to the off ( O ) position.
4.
Connect the power cord into the appliance inlet located in the chassis directly above the AC power supply.
5.
Insert the power cord plug into an external AC power source receptacle.
NOTE: Each power supply must be connected to a dedicated AC power feed and a dedicated customer site circuit breaker. We recommend that you use a 15 A (250 VAC) minimum, or as required by local code.
Copyright © 2017, Juniper Networks, Inc.
227
MX960 3D Universal Edge Router Hardware Guide
6.
Dress the power cord appropriately. Verify that the power cord does not block the air exhaust and access to router components, or drape where people could trip on it.
7.
Repeat Step
through Step
for the remaining power supplies.
Figure 70: Connecting AC Power to the MX960 Router
228
Related
Documentation
•
Grounding the MX960 Router on page 226
•
AC Power Cord Specifications for the MX960 Router on page 165
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Powering On an AC-Powered MX960 Router with Normal Capacity Power Supplies on page 232
•
Connecting Power to an AC-Powered MX960 Router with High-Capacity Power Supplies on page 229
Copyright © 2017, Juniper Networks, Inc.
Chapter 17: Connecting the MX960 Router to Power
Connecting Power to an AC-Powered MX960 Router with High-Capacity Power Supplies
NOTE: A minimum of two AC nominal 220 VAC 20 amp power cords are required for this procedure.
To install an MX960 high-capacity AC power supply, use the following procedure (see
).
1.
Verify that the power switch on the power supply is in the off ( O ) position.
2.
Ensure that the release lever below the empty power supply slot is locked in the counterclockwise position (see
).
Figure 71: MX960 with High-Capacity AC Power Supplies Installed
Air exhaust
Input mode switch
AC Power supplies
Power supply ejectors
Grounding points ESD point
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
3.
On the power supply, rotate the metal cover away from the input mode switch to expose the switch.
4.
Move the input mode switch to position 0 for one feed or position 1 for two feeds (see
Copyright © 2017, Juniper Networks, Inc.
229
MX960 3D Universal Edge Router Hardware Guide
Figure 72: MX960 AC Power Input Mode Switch
230
1
0
1
0
CAUTION: Do not use a pencil, because fragments can break off and cause damage to the power supply.
5.
Using both hands, slide the power supply straight into the chassis until the power supply is fully seated in the chassis slot. The power supply faceplate will protrude beyond the chassis.
The small tab on the metal housing that is controlled by the release lever must be inside of the corresponding slot at the bottom of the power supply (see
Figure 72 on page 230 ). This tab is used to pull the power supply down in the chassis
slot, prior to removing the power supply.
6.
While firmly pushing the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever clockwise until it stops.
7.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
8.
Locate a power cord with the type of plug appropriate for your geographical location
(see
“AC Power Cord Specifications for the MX960 Router” on page 165
).
9.
Plug the power cord into the corresponding appliance inlet located in the chassis directly above the power supply. This is the recommend receptacle when using the power supply in one-feed mode. If using the power supply in two-feed mode, plug the second power cord into the receptacle on the power supply.
Copyright © 2017, Juniper Networks, Inc.
Chapter 17: Connecting the MX960 Router to Power
NOTE: Each power supply must be connected to a dedicated AC power feed and a dedicated customer site circuit breaker.
NOTE: To use HC-PSs with full capacity you have to switch them to two feed mode and use two power corders per HC-PS.
10.
Dress the power cords appropriately. Verify that the power cord does not block the air exhaust and access to router components, and that they do not drape where people could trip on them.
11.
Move the AC input switch above the power supply to the on ( — ) position. This is the only switch you have to turn on if you are using the power supply in one feed mode. If using the power supply in two-feed mode, move the power switch on the power supply to the on position. Remember to turn on both switches when operating the power supply in two-feed mode.
12.
If the power supply is correctly installed and functioning normally, the AC1 OK , AC2 OK
(two-feed mode only) DC OK LEDs light steadily, and the PS FAIL LED is not lit. See
Table 98: MX960 High-Capacity AC Power Supply LEDs
LEDs
Connected
Inputs
DIP Switch
Position AC-1 OK AC-2 OK DC OK PS FAIL
0 (1 input) Green Off Green Off PDM connected, power supply disconnected
PDM disconnected, power supply connected
0 (1 input) Off Green Green Off
PDM connected, power supply connected
PDM connected, power supply disconnected
PDM disconnected, power supply connected
0 (1 input)
1 (2 inputs)
1 (2 inputs)
Green
Green
Off
Green
Off
Green
Green
Off
Off
Off
Red
Red
Copyright © 2017, Juniper Networks, Inc.
231
MX960 3D Universal Edge Router Hardware Guide
Table 98: MX960 High-Capacity AC Power Supply LEDs
(continued)
LEDs
Connected
Inputs
DIP Switch
Position AC-1 OK AC-2 OK DC OK
PDM connected, power supply connected
1 (2 inputs) Green Green Green
PS FAIL
Off
Note: The corresponding appliance inlet located in the chassis directly above the power supply is the recommend receptacle when using the power supply in one feed mode. If using the power supply in two-feed mode, plug the second power cord into the receptacle on the power supply
Note: PDM in the above table stands for Power Distribution Module.
13.
Repeat steps 1-12 for installing power supplies in slots 1, 2, and 3, where required.
Powering On an AC-Powered MX960 Router with Normal Capacity Power Supplies
To power on an AC-powered router:
1.
Verify that the power supplies are fully inserted in the chassis.
2.
Verify that each AC power cord is securely inserted into its appliance inlet.
3.
Verify that an external management device is connected to one of the Routing Engine ports ( AUX , CONSOLE , or ETHERNET ).
4.
Turn on the power to the external management device.
5.
Switch on the dedicated customer site circuit breakers. Follow the ESD and safety instructions for your site.
6.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
7.
Switch the AC switch in the chassis above each power supply to the on ( — ) position.
8.
Check that the AC power supply is correctly installed and functioning normally. Verify that the AC OK and DC OK LEDs light steadily, and the PS FAIL LED is not lit.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the status LEDs on the power supply and the show chassis command display—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first
60 seconds.
232 Copyright © 2017, Juniper Networks, Inc.
Chapter 17: Connecting the MX960 Router to Power
If any of the status LEDs indicates that the power supply is not functioning normally, repeat the installation and cabling procedures.
9.
On the external management device connected to the Routing Engine, monitor the startup process to verify that the system has booted properly.
NOTE: If the system is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. Normally, the router boots from the Junos OS on the
CompactFlash card.
After powering on a power supply, wait at least 60 seconds before turning it off.
Related
Documentation
•
Connecting Power to an AC-Powered MX960 Router with High-Capacity Power Supplies on page 229
•
Connecting the MX960 Router to Management and Alarm Devices on page 247
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing an MX960 AC Power Supply on page 391
•
Powering Off the MX960 Router on page 242
Connecting Power to a DC-Powered MX960 Router with Normal-Capacity Power
Supplies
CAUTION: Do not mix AC and DC power supplies within the same router.
Damage to the router might occur.
WARNING: Before performing DC power procedures, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.
You connect DC power to the router by attaching power cables from the external DC power sources to the terminal studs on the power supply faceplates. You must provide the power cables (the cable lugs are supplied with the router).
Copyright © 2017, Juniper Networks, Inc.
233
MX960 3D Universal Edge Router Hardware Guide
234
To connect the DC source power cables to the router:
1.
Switch off the dedicated customer site circuit breakers. Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Move the DC circuit breaker on the power supply faceplate to the off ( O ) position.
4.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
5.
Verify that the DC power cables are correctly labeled before making connections to the power supply. In a typical power distribution scheme where the return is connected to chassis ground at the battery plant, you can use a multimeter to verify the resistance of the –48V and RTN DC cables to chassis ground:
• The cable with very large resistance (indicating an open circuit) to chassis ground is –48V .
• The cable with very low resistance (indicating a closed circuit) to chassis ground is
RTN .
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
6.
Remove the nut and washer from each of the terminal studs. (Use a 7/16-in.
[11 mm] nut driver or socket wrench.)
7.
Secure each power cable lug to the terminal studs, first with the split washer, then with the nut (see
). Apply between 23 lb-in. (2.6 Nm) and 25 lb-in.
(2.8 Nm) of torque to each nut. Do not overtighten the nut. (Use a 7/16-in. [11 mm] torque-controlled driver or socket wrench.) a. Secure each positive (+) DC source power cable lug to the RTN (return) terminal.
b. Secure each negative (–) DC source power cable lug to the –48V (input) terminal.
CAUTION: Ensure that each power cable lug seats flush against the surface of the terminal block as you are tightening the nuts. Ensure that each nut is properly threaded onto the terminal stud. The nut should be able to spin
Copyright © 2017, Juniper Networks, Inc.
Chapter 17: Connecting the MX960 Router to Power freely with your fingers when it is first placed onto the terminal stud.
Applying installation torque to the nut when improperly threaded may result in damage to the terminal stud.
CAUTION: The maximum torque rating of the terminal studs on the DC power supply is 58 lb-in. (6.5 Nm). The terminal studs may be damaged if excessive torque is applied. Use only a torque-controlled driver or socket wrench to tighten nuts on the DC power supply terminal studs.
NOTE: The DC power supplies in slots PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A , and the DC power supplies in slots PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B . This configuration provides the commonly deployed
A/B feed redundancy for the system.
8.
Loosen the captive screw on the cable restraint on the lower edge of the power supply faceplate.
9.
Route the positive and negative DC power cables through the left and right sides of the cable restraint.
10.
Tighten the cable restraint captive screw to hold the power cables in place.
11.
Replace the clear plastic cover over the terminal studs on the faceplate.
12.
Verify that the power cables are connected correctly, that they are not touching or blocking access to router components, and that they do not drape where people could trip on them.
13.
Repeat Steps
through
for the remaining power supplies.
Copyright © 2017, Juniper Networks, Inc.
235
MX960 3D Universal Edge Router Hardware Guide
Figure 73: Connecting DC Power to the MX960 Router
Related
Documentation
•
DC Power Cable Specifications for the MX960 Router on page 185
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Powering On a DC-Powered MX960 Router with Normal Capacity Power Supplies on page 240
Connecting Power to a DC-Powered MX960 Router with High-Capacity Power Supplies
To install an MX960 DC high-capacity DC power supply:
1.
Verify that the power switch on the power supply is in the off ( O ) position.
2.
On the power supply, rotate the metal cover away from the input mode switch to expose the switch.
3.
Move the input mode switch to position 0 for one feed or position 1 for two feeds (see
NOTE: For a fully redundant configuration in two-feed mode, eight feeds are required. For a non-redundant configuration, four feeds are required.
236 Copyright © 2017, Juniper Networks, Inc.
Chapter 17: Connecting the MX960 Router to Power
Figure 74: MX960 with High-Capacity DC Power Supplies Installed
Air exhaust
Input mode switch
DC Power supplies
Power supply ejectors
Grounding points ESD point
CAUTION: Do not use a pencil, because fragments can break off and cause damage to the power supply.
4.
Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
5.
Ensure that the release lever below the empty power supply slot is locked in the counterclockwise position.
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
6.
Using both hands, slide the power supply straight into the chassis until the power supply is fully seated in the chassis slot.
The small tab on the metal housing that is controlled by the release lever must be inside of the corresponding slot at the bottom of the power supply. This tab is used to pull the power supply down in the chassis slot, prior to removing the power supply.
7.
While firmly pushing the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever clockwise until it stops.
Copyright © 2017, Juniper Networks, Inc.
237
MX960 3D Universal Edge Router Hardware Guide
238
8.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
9.
Remove the cover protecting the terminal studs on the faceplate.
10.
Remove the nut and washer from each of the terminal studs.
11.
Secure each power cable lug to the terminal studs, first with the split washer, then with the nut. Apply between 23 in-lb. (2.6 Nm) and 25 in-lb. (2.8 Nm) of torque to each nut. Do not overtighten the nut. (Use a 7/16-in. [11-mm] torque-controlled driver or socket wrench.) a. On INPUT 0 , attach the positive (+) DC source power cable lug to the RTN (return) terminal as shown in
Figure 74 on page 237 . Repeat this step for
INPUT 1 if using two feeds.
b. On INPUT 0 attach the negative (–) DC source power cable lug to the –48V (input) terminal. Repeat this step for INPUT 1 if using two feeds.
CAUTION: Ensure that each power cable lug seats flush against the surface of the terminal block as you are tightening the nuts. Ensure that each nut is properly threaded onto the terminal stud. The nut should be able to spin freely with your fingers when it is first placed onto the terminal stud.
Applying installation torque to the nut when improperly threaded may result in damage to the terminal stud.
CAUTION: The maximum torque rating of the terminal studs on the DC power supply is 36 in-lb. (4.0 Nm). The terminal studs may be damaged if excessive torque is applied. Use only a torque-controlled driver or socket wrench to tighten nuts on the DC power supply terminal studs.
NOTE: The DC power supplies in slots PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A , and the DC power supplies in PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B . This configuration provides the commonly deployed A/B feed redundancy for the system. For information about connecting to DC power sources, see
“Electrical Specifications for the MX960 DC Power Supply” on page 169 .
12.
Verify that the power cabling is correct, that the cables are not touching, and that they do not block access to router components or drape where people could trip on them.
13.
Replace the clear plastic cover over the terminal studs on the faceplate.
Copyright © 2017, Juniper Networks, Inc.
Chapter 17: Connecting the MX960 Router to Power
14.
Switch on the dedicated customer site circuit breaker.
15.
Verify that the INPUT 0 OK or INPUT 1 OK LEDs on the power supply are lit green steadily. If using two feeds, verify that both INPUT 0 OK and INPUT 1 OK LEDs on the power supply are lit steadily. The INPUT OK will be lit amber if that input’s voltage is in reverse polarity. Check the polarity of the power cables to fix the condition (see
and
16.
Move the switch to the on ( | ) position.
17.
Verify that the DC OK LED is lit green steadily. See
for information on MX960 high-capacity DC LEDs.
Table 99: MX960 High-Capacity DC Power Supply LEDs
LEDs
Connected Inputs
DIP
Switch
Position INP-0 OK INP-1 OK DC OK PS FAIL
0 (1 input)
INP0 connected, INP1 disconnected
INP0 disconnected, INP1 connected
INP0 connected, INP1 connected
INP0 connected, INP1 disconnected
INP0 disconnected, INP1 connected
1 (2 inputs)
Green
Off
Green
Green
Off
Off
Green
Green
Off
Green
Green
Green
Green
Off
Off
Off
Off
Off
Red
Red
INP0 connected, INP1 connected Green Green Green Off
18.
Repeat steps 1-17 for installing power supplies in slots 1, 2, and 3, where required.
Copyright © 2017, Juniper Networks, Inc.
239
MX960 3D Universal Edge Router Hardware Guide
Figure 75: MX960 DC High-Capacity Power Supply Front View
19.
Install a blank panel over the power distribution modules, if available.
Powering On a DC-Powered MX960 Router with Normal Capacity Power Supplies
1.
Verify that an external management device is connected to one of the Routing Engine ports ( AUX , CONSOLE , or ETHERNET ).
2.
Turn on the power to the external management device.
3.
Verify that the power supplies are fully inserted in the chassis.
4.
Verify that the source power cables are connected to the appropriate terminal: the positive (+) source cable to the return terminal (labeled RTN ) and the negative (–) source cable to the input terminal (labeled –48V ).
5.
Switch on the dedicated customer site circuit breakers to provide power to the DC power cables. Follow your site’s procedures.
6.
Check that the INPUT OK LED is lit steadily green to verify that power is present.
240 Copyright © 2017, Juniper Networks, Inc.
Chapter 17: Connecting the MX960 Router to Power
7.
If power is not present:
• Verify that the fuse is installed correctly, and turn on the breaker at the battery distribution fuse board or fuse bay.
• Check the voltage with a meter at the terminals of the power supply for correct voltage level and polarity.
8.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
9.
On each of the DC power supplies, switch the DC circuit breaker to the center position before moving it to the on ( | ) position.
NOTE: The circuit breaker may bounce back to the off ( O ) position if you move the breaker too quickly.
10.
Verify that the BREAKER ON LED is lit green steadily.
11.
Verify that the PWR OK LED is lit green steadily, indicating the power supply is correctly installed and functioning normally.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the status LEDs on the power supply and the show chassis command display—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first
60 seconds.
If any of the status LEDs indicates that the power supply is not functioning normally, repeat the installation and cabling procedures.
12.
On the external management device connected to the Routing Engine, monitor the startup process to verify that the system has booted properly.
NOTE: If the system is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. Normally, the router boots from the Junos OS on the
CompactFlash card.
After powering on a power supply, wait at least 60 seconds before turning it off. To power off the system after the Routing Engine finishes booting, see
“Powering Off the MX960 Router” on page 242 .
Copyright © 2017, Juniper Networks, Inc.
241
MX960 3D Universal Edge Router Hardware Guide
Related
Documentation
•
Connecting Power to a DC-Powered MX960 Router with High-Capacity Power Supplies on page 236
•
Connecting the MX960 Router to Management and Alarm Devices on page 247
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing an MX960 DC Power Supply on page 395
Powering Off the MX960 Router
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
To power off the router:
1.
On the external management device connected to the Routing Engine, issue the request system halt both-routing-engines operational mode command. The command shuts down the Routing Engines cleanly, so their state information is preserved. (If the router contains only one Routing Engine, issue the request system halt command.) user@host> request system halt both-routing-engines
2.
Wait until a message appears on the console confirming that the operating system has halted. For more information about the command, see the CLI Explorer .
3.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
4.
Move the AC input switch on the chassis above the AC power supply or the DC circuit breaker on each DC power supply faceplate to the off ( O ) position.
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Grounding the MX960 Router on page 226
•
Powering On an AC-Powered MX960 Router with Normal Capacity Power Supplies on page 232
•
Powering On a DC-Powered MX960 Router with Normal Capacity Power Supplies on page 240
242 Copyright © 2017, Juniper Networks, Inc.
Chapter 17: Connecting the MX960 Router to Power
Connecting an MX960 AC Power Supply Cord
To connect the AC power cord:
1.
Locate a replacement power cord with the type of plug appropriate for your geographical location (see
“AC Power Cord Specifications for the MX960 Router” on page 165
).
2.
Plug the replacement power cord into the corresponding appliance inlet located in the chassis directly above the power supply.
3.
Insert the power cord plug into an external AC power source receptacle.
NOTE: Each power supply must be connected to a dedicated AC power feed and a dedicated customer site circuit breaker. We recommend that you use a 15 A (250 VAC) minimum, or as required by local code.
4.
Dress the power cord appropriately. Verify that the power cord does not block the air exhaust and access to router components, or drape where people could trip on it.
5.
Move the AC input switch in the chassis above the power supply to the on ( — )position and observe the status LEDs on the power supply faceplate. If the power supply is correctly installed and functioning normally, the AC OK and DC OK LEDs light steadily, and the PS FAIL LED is not lit.
Related
Documentation
•
MX960 AC Power Supply Description on page 98
•
Disconnecting an MX960 AC Power Supply Cord on page 403
• MX960 AC Power Electrical Safety Guidelines and Warnings
•
Replacing an MX960 AC Power Supply on page 391
Copyright © 2017, Juniper Networks, Inc.
243
MX960 3D Universal Edge Router Hardware Guide
Connecting an MX960 DC Power Supply Cable
WARNING: Before performing DC power procedures, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.
To connect a power cable for a DC power supply:
1.
Locate a replacement power cable that meets the specifications defined in
Specifications for the MX960 DC Power Supply” on page 169
.
2.
Verify that a licensed electrician has attached a cable lug to the replacement power cable.
3.
Verify that the INPUT OK LED is off.
4.
Secure the power cable lug to the terminal studs, first with the split washer, then with the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut (see
Figure 76 on page 245 ). Do not overtighten the nut. (Use a 7/16-in. (11 mm)
torque-controlled driver or socket wrench.)
CAUTION: Ensure that each power cable lug seats flush against the surface of the terminal block as you are tightening the nuts. Ensure that each nut is properly threaded onto the terminal stud. The nut should be able to spin freely with your fingers when it is first placed onto the terminal stud.
Applying installation torque to the nut when improperly threaded may result in damage to the terminal stud.
CAUTION: The maximum torque rating of the terminal studs on the DC power supply is 58 lb-in. (6.5 Nm). The terminal studs may be damaged if excessive torque is applied. Use only a torque-controlled driver or socket wrench to tighten nuts on the DC power supply terminal studs.
244 Copyright © 2017, Juniper Networks, Inc.
Chapter 17: Connecting the MX960 Router to Power
Figure 76: Connecting Power Cables to the DC Power Supply
Cable
Split lug
Terminal studs washer
Nut
5.
Route the power cable through the cable restraint. Make sure that the cable does not touch or obstruct any router components.
6.
Tighten the cable restraint captive screw to hold the power cables in place.
7.
Verify that the DC power cable is connected correctly, that it does not touch or block access to router components, and that it does not drape where people could trip on it.
8.
Replace the clear plastic cover over the terminal studs on the faceplate.
9.
Attach the power cable to the DC power source.
10.
Turn on the dedicated customer site circuit breaker to the power supply.
11.
Verify that the INPUT OK LED on the power supply is lit steadily.
12.
On each of the DC power supplies, switch the DC circuit breaker to the center position before moving it to the on ( | ) position.
NOTE: The circuit breaker may bounce back to the off ( O ) position if you move the breaker too quickly.
Copyright © 2017, Juniper Networks, Inc.
245
MX960 3D Universal Edge Router Hardware Guide
Observe the status LEDs on the power supply faceplate. If the power supply is correctly installed and functioning normally, the PWR OK , BRKR ON , and INPUT OK LEDs light green steadily.
Related
Documentation
•
DC Power Cable Specifications for the MX960 Router on page 185
•
Disconnecting an MX960 DC Power Supply Cable on page 405
•
MX960 DC Power Supply on page 104
• MX960 DC Power Electrical Safety Guidelines
246 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 18
Connecting the MX960 Router to the
Network
•
Tools and Parts Required for MX960 Router Connections on page 247
•
Connecting the MX960 Router to Management and Alarm Devices on page 247
•
Connecting the MX960 Router to a Network for Out-of-Band Management on page 250
•
Connecting the MX960 Router to a Management Console or Auxiliary Device on page 251
•
Connecting an MX960 Router to an External Alarm-Reporting Device on page 252
•
Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router on page 253
•
Connecting the Alarm Relay Wires to the MX960 Craft Interface on page 255
Tools and Parts Required for MX960 Router Connections
To connect the router to management devices and line cards, you need the following tools and parts:
• Phillips (+) screwdrivers, numbers 1 and 2
• 2.5-mm flat-blade (–) screwdriver
• 2.5-mm Phillips (+) screwdriver
• Wire cutters
• Electrostatic discharge (ESD) grounding wrist strap
Related
Documentation
•
Connecting the MX960 Router to a Network for Out-of-Band Management on page 248
•
Connecting the MX960 Router to a Management Console or Auxiliary Device on page 248
•
Connecting an MX960 Router to an External Alarm-Reporting Device on page 249
Connecting the MX960 Router to Management and Alarm Devices
•
Connecting the MX960 Router to a Network for Out-of-Band Management on page 248
•
Connecting the MX960 Router to a Management Console or Auxiliary Device on page 248
•
Connecting an MX960 Router to an External Alarm-Reporting Device on page 249
Copyright © 2017, Juniper Networks, Inc.
247
MX960 3D Universal Edge Router Hardware Guide
Connecting the MX960 Router to a Network for Out-of-Band Management
To connect the Routing Engine to a network for out-of-band management, connect an
Ethernet cable with RJ-45 connectors to the ETHERNET port on the Routing Engine. One
Ethernet cable is provided with the router. To connect to the ETHERNET port on the
Routing Engine:
1.
Turn off the power to the management device.
2.
Plug one end of the Ethernet cable ( Figure 78 on page 248
shows the connector) into the ETHERNET port on the Routing Engine.
shows the port.
3.
Plug the other end of the cable into the network device.
Figure 77: Ethernet Port
Figure 78: Routing Engine Ethernet Cable Connector
Connecting the MX960 Router to a Management Console or Auxiliary Device
To use a system console to configure and manage the Routing Engine, connect it to the appropriate CONSOLE port on the Routing Engine. To use a laptop, modem, or other auxiliary device, connect it to the AUX port on the Routing Engine. Both ports accept a cable with an RJ-45 connector. One serial cable with an RJ-45 connector and a DB-9 connector is provided with the router. To connect a device to the CONSOLE port and another device to the AUX port, you must supply an additional cable.
To connect a management console or auxiliary device:
1.
Turn off the power to the console or auxiliary device.
2.
Plug the RJ-45 end of the serial cable ( Figure 80 on page 249
shows the connector) into the AUX port or CONSOLE port on the Routing Engine.
shows the ports.
3.
Plug the female DB-9 end into the device's serial port.
248 Copyright © 2017, Juniper Networks, Inc.
Chapter 18: Connecting the MX960 Router to the Network
NOTE:
For console devices, configure the serial port to the following values:
• Baud rate—9600
• Parity—N
• Data bits—8
• Stop bits—1
• Flow control—none
Figure 79: Auxiliary and Console Ports
Figure 80: Routing Engine Console and Auxiliary Cable Connector
Connecting an MX960 Router to an External Alarm-Reporting Device
To connect the router to external alarm-reporting devices, attach wires to the RED and
YELLOW relay contacts on the craft interface. (See
.) A system condition that triggers the red or yellow alarm LED on the craft interface also activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router.
They accept wire of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
To connect an external device to an alarm relay contact (see
):
1.
Prepare the required length of wire with gauge between 28-AWG and 14-AWG (0.08
and 2.08 mm
2
).
2.
While the terminal block is not plugged into the relay contact, use a 2.5-mm flat-blade screwdriver to loosen the small screws on its side. With the small screws on its side facing left, insert wires into the slots in the front of the block based on the wiring for the external device. Tighten the screws to secure the wire.
Copyright © 2017, Juniper Networks, Inc.
249
MX960 3D Universal Edge Router Hardware Guide
3.
Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
4.
Attach the other end of the wires to the external device.
To attach a reporting device for the other kind of alarm, repeat the procedure.
Figure 81: Alarm Relay Contacts
Related
Documentation
•
Tools and Parts Required for MX960 Router Connections on page 247
•
Replacing Connections to MX960 Routing Engine Interface Ports on page 343
•
Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router on page 253
•
Routing Engine Interface Cable and Wire Specifications for MX Series Routers on page 142
Connecting the MX960 Router to a Network for Out-of-Band Management
To connect the Routing Engine to a network for out-of-band management, connect an
Ethernet cable with RJ-45 connectors to the ETHERNET port on the Routing Engine. One
Ethernet cable is provided with the router. To connect to the ETHERNET port on the
Routing Engine:
1.
Turn off the power to the management device.
2.
Plug one end of the Ethernet cable ( Figure 78 on page 248
shows the connector) into the ETHERNET port on the Routing Engine.
shows the port.
3.
Plug the other end of the cable into the network device.
Figure 82: Ethernet Port
250 Copyright © 2017, Juniper Networks, Inc.
Chapter 18: Connecting the MX960 Router to the Network
Figure 83: Routing Engine Ethernet Cable Connector
Related
Documentation
•
Routing Engine Interface Cable and Wire Specifications for MX Series Routers on page 142
•
Tools and Parts Required for MX960 Router Connections on page 247
•
Replacing Connections to MX960 Routing Engine Interface Ports on page 343
•
Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router on page 253
•
Connecting the MX960 Router to a Management Console or Auxiliary Device on page 248
•
Connecting an MX960 Router to an External Alarm-Reporting Device on page 249
Connecting the MX960 Router to a Management Console or Auxiliary Device
To use a system console to configure and manage the Routing Engine, connect it to the appropriate CONSOLE port on the Routing Engine. To use a laptop, modem, or other auxiliary device, connect it to the AUX port on the Routing Engine. Both ports accept a cable with an RJ-45 connector. One serial cable with an RJ-45 connector and a DB-9 connector is provided with the router. To connect a device to the CONSOLE port and another device to the AUX port, you must supply an additional cable.
To connect a management console or auxiliary device:
1.
Turn off the power to the console or auxiliary device.
2.
Plug the RJ-45 end of the serial cable ( Figure 80 on page 249
shows the connector) into the AUX port or CONSOLE port on the Routing Engine.
shows the ports.
3.
Plug the female DB-9 end into the device's serial port.
NOTE:
For console devices, configure the serial port to the following values:
• Baud rate—9600
• Parity—N
• Data bits—8
• Stop bits—1
• Flow control—none
Copyright © 2017, Juniper Networks, Inc.
251
MX960 3D Universal Edge Router Hardware Guide
Figure 84: Auxiliary and Console Ports
Figure 85: Routing Engine Console and Auxiliary Cable Connector
Related
Documentation
•
Routing Engine Interface Cable and Wire Specifications for MX Series Routers on page 142
•
Tools and Parts Required for MX960 Router Connections on page 247
•
Replacing Connections to MX960 Routing Engine Interface Ports on page 343
•
Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router on page 253
•
Connecting an MX960 Router to an External Alarm-Reporting Device on page 249
Connecting an MX960 Router to an External Alarm-Reporting Device
To connect the router to external alarm-reporting devices, attach wires to the RED and
YELLOW relay contacts on the craft interface. (See
.) A system condition that triggers the red or yellow alarm LED on the craft interface also activates the corresponding alarm relay contact.
The terminal blocks that plug into the alarm relay contacts are supplied with the router.
They accept wire of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm
2
), which is not provided. Use the gauge of wire appropriate for the external device you are connecting.
To connect an external device to an alarm relay contact (see
):
1.
Prepare the required length of wire with gauge between 28-AWG and 14-AWG (0.08
and 2.08 mm
2
).
2.
While the terminal block is not plugged into the relay contact, use a 2.5-mm flat-blade screwdriver to loosen the small screws on its side. With the small screws on its side facing left, insert wires into the slots in the front of the block based on the wiring for the external device. Tighten the screws to secure the wire.
252 Copyright © 2017, Juniper Networks, Inc.
Chapter 18: Connecting the MX960 Router to the Network
3.
Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
4.
Attach the other end of the wires to the external device.
To attach a reporting device for the other kind of alarm, repeat the procedure.
Figure 86: Alarm Relay Contacts
Related
Documentation
•
Tools and Parts Required for MX960 Router Connections on page 247
•
Replacing Connections to MX960 Routing Engine Interface Ports on page 343
•
Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router on page 253
•
Connecting the MX960 Router to a Management Console or Auxiliary Device on page 248
•
Connecting the MX960 Router to a Network for Out-of-Band Management on page 248
Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router
To connect the DPCs, MPCs, MICs, or PICs to the network (see
and
1.
Have ready a length of the type of cable used by the component. For cable specifications, see the MX Series Interface Module Reference .
2.
Remove the rubber safety plug from the cable connector port.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the faceplate.
Copyright © 2017, Juniper Networks, Inc.
253
MX960 3D Universal Edge Router Hardware Guide
NOTE: The XFP cages and optics on the components are industry standard parts that have limited tactile feedback for insertion of optics and fiber.
You need to insert the optics and fiber firmly until the latch is securely in place.
4.
Arrange the cable to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
Figure 87: Attaching a Cable to a DPC
Figure 88: Attaching a Cable to a MIC
Fiber-optic cable connector
Fiber-optic cable
254 Copyright © 2017, Juniper Networks, Inc.
Chapter 18: Connecting the MX960 Router to the Network
Related
Documentation
•
Connecting the MX960 Router to Management and Alarm Devices on page 247
•
Tools and Parts Required for MX960 Router Connections on page 247
•
Grounding the MX960 Router on page 226
Connecting the Alarm Relay Wires to the MX960 Craft Interface
To connect the alarm relay wires between a router and an alarm-reporting device (see
):
1.
Prepare the required length of replacement wire with gauge between 28-AWG and
14-AWG (0.08 and 2.08 mm
2
).
2.
Insert the replacement wires into the slots in the front of the block. Use a 2.5-mm flat-blade screwdriver to tighten the screws and secure the wire.
3.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
4.
Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
5.
Attach the other end of the wires to the external device.
Figure 89: Alarm Relay Contacts
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Disconnecting the Alarm Relay Wires from the MX960 Craft Interface on page 307
•
Removing the MX960 Craft Interface on page 308
•
Installing the MX960 Craft Interface on page 265
•
MX960 Craft Interface Overview on page 15
Copyright © 2017, Juniper Networks, Inc.
255
MX960 3D Universal Edge Router Hardware Guide
256 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 19
Initially Configuring the MX960 Router
•
Initially Configuring the MX960 Router on page 257
Initially Configuring the MX960 Router
The MX240 router is shipped with Junos OS preinstalled and ready to be configured when the MX240 router is powered on. There are three copies of the software: one on a
CompactFlash card in the Routing Engine, one on a rotating hard disk in the Routing
Engine, and one on a USB flash drive that can be inserted into the slot in the Routing
Engine faceplate.
When the router boots, it first attempts to start the image on the USB flash drive. If a
USB flash drive is not inserted into the Routing Engine or the attempt otherwise fails, the router next tries the CompactFlash card (if installed), and finally the hard disk.
You configure the router by issuing Junos OS command-line interface (CLI) commands, either on a console device attached to the CONSOLE port on the Routing Engine, or over a telnet connection to a network connected to the ETHERNET port on the Routing Engine.
Gather the following information before configuring the router:
• Name the router will use on the network
• Domain name the router will use
• IP address and prefix length information for the Ethernet interface
• IP address of a default router
• IP address of a DNS server
• Password for the root user
This procedure connects the router to the network but does not enable it to forward traffic. For complete information about enabling the router to forward traffic, including examples, see the Junos OS configuration guides.
To configure the software:
1.
Verify that the router is powered on.
2.
Log in as the “root” user. There is no password.
Copyright © 2017, Juniper Networks, Inc.
257
MX960 3D Universal Edge Router Hardware Guide
3.
Start the CLI.
root# cli root@>
4.
Enter configuration mode.
cli> configure
[edit] root@#
5.
Configure the name of the router. If the name includes spaces, enclose the name in quotation marks (“ ”).
[edit] root@# set system host-name host-name
6.
Create a management console user account.
[edit] root@# set system login user user-name authentication plain-text-password
New password: password
Retype new password: password
7.
Set the user account class to super-user.
[edit] root@# set system login user user-name class super-user
8.
Configure the router’s domain name.
[edit] root@# set system domain-name domain-name
9.
Configure the IP address and prefix length for the router’s Ethernet interface.
[edit] root@# set interfaces fxp0 unit 0 family inet address address/prefix-length
10.
Configure the IP address of a backup router, which is used only while the routing protocol is not running.
[edit] root@# set system backup-router address
11.
Configure the IP address of a DNS server.
[edit] root@# set system name-server address
12.
Set the root authentication password by entering either a clear-text password, an encrypted password, or an SSH public key string (DSA or RSA).
258 Copyright © 2017, Juniper Networks, Inc.
Chapter 19: Initially Configuring the MX960 Router
[edit] root@# set system root-authentication plain-text-password
New password: password
Retype new password: password or
[edit] root@# set system root-authentication encrypted-password encrypted-password or
[edit] root@# set system root-authentication ssh-dsa public-key or
[edit] root@# set system root-authentication ssh-rsa public-key
13.
(Optional) Configure the static routes to remote subnets with access to the management port. Access to the management port is limited to the local subnet. To access the management port from a remote subnet, you need to add a static route to that subnet within the routing table. For more information about static routes, see the Junos OS Administration Library .
[edit] root@# set routing-options static route remote-subnet next-hop destination-IP retain no-readvertise
14.
Configure the telnet service at the [edit system services] hierarchy level.
[edit] root@# set system services telnet
15.
(Optional) Display the configuration to verify that it is correct.
[edit] root@# show system { host-name host-name; domain-name domain-name; backup-router address; root-authentication {
authentication-method (password | public-key);
} name-server {
address;
}
} interfaces { fxp0 { unit 0 { family inet { address address/prefix-length;
}
}
Copyright © 2017, Juniper Networks, Inc.
259
MX960 3D Universal Edge Router Hardware Guide
}
}
16.
Commit the configuration to activate it on the router.
[edit] root@# commit
17.
(Optional) Configure additional properties by adding the necessary configuration statements. Then commit the changes to activate them on the router.
[edit] root@host# commit
18.
When you have finished configuring the router, exit configuration mode.
[edit] root@host# exit root@host>
NOTE: To reinstall Junos OS, you boot the router from the removable media.
Do not insert the removable media during normal operations. The router does not operate normally when it is booted from the removable media.
When the router boots from the storage media (removable media, CompactFlash card, or hard disk) it expands its search in the /config directory of the routing platform for the following files in the following order: juniper.conf
(the main configuration file), rescue.conf
(the rescue configuration file), and juniper.conf.1
(the first rollback configuration file).
When the search finds the first configuration file that can be loaded properly, the file loads and the search ends. If none of the file can be loaded properly, the routing platform does not function properly. If the router boots from an alternate boot device, Junos OS displays a message indication this when you log in to the router.
Related
Documentation
•
Powering On an AC-Powered MX960 Router with Normal Capacity Power Supplies on page 232
•
Powering On a DC-Powered MX960 Router with Normal Capacity Power Supplies on page 240
•
Grounding the MX960 Router on page 226
•
Routine Maintenance Procedures for the MX960 Router on page 443
260 Copyright © 2017, Juniper Networks, Inc.
PART 4
Installing and Replacing Components
•
Overview of Installing and Replacing Components on page 263
•
Installing Components on page 265
•
Replacing Chassis Components on page 307
•
Replacing Cooling System Component on page 325
•
Replacing Host Subsystem Components on page 333
•
Replacing Line Card Components on page 355
•
Replacing Power System Components on page 391
•
Replacing Switch Fabric Components on page 409
Copyright © 2017, Juniper Networks, Inc.
261
MX960 3D Universal Edge Router Hardware Guide
262 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 20
Overview of Installing and Replacing
Components
•
MX960 Field-Replaceable Units on page 263
•
Tools and Parts Required for MX960 Router Connections on page 264
MX960 Field-Replaceable Units
Field-replaceable units (FRUs) are router components that can be replaced at the customer site. Replacing most FRUs requires minimal router downtime. The router uses the following types of FRUs:
• Hot-removable and hot-insertable FRUs—You can remove and replace these components without powering off the router or disrupting the routing functions.
• Hot-pluggable FRUs—You can remove and replace these components without powering off the router, but the routing functions of the system are interrupted when the component is removed.
lists the FRUs for the MX960 router. Before you replace an SCB or a Routing Engine, you must take the host subsystem offline.
Copyright © 2017, Juniper Networks, Inc.
263
MX960 3D Universal Edge Router Hardware Guide
Table 100: Field-Replaceable Units
Hot-Removable and Hot-Insertable FRUs Hot-Pluggable FRUs
•
•
•
•
•
•
•
•
•
•
•
•
•
Air filter
Craft interface
Backup Switch Control Board (SCB) (if redundant)
Master Switch Control Board (SCB) (if nonstop active routing is configured)
Backup Routing Engine (if redundant)
Master Routing Engine (if nonstop active routing is configured)
Dense Port Concentrators (DPCs)
Flexible PIC Concentrators (FPCs)
Modular Port Concentrators (MPCs)
Modular Interface Cards (MICs)
PICs
AC and DC power supplies (if redundant)
Fan tray
•
•
•
•
•
Master Switch Control Board (SCB) (if nonstop active routing is not configured)
Master Routing Engine (if nonstop active routing is not configured)
Switch Control Board (SCB) (nonredundant)
Routing Engine (nonredundant)
Solid-state drives (SSDs) of Routing Engines
Related
Documentation
• Taking an MX960 Host Subsystem Offline
• Tools and Parts Required to Replace MX960 Hardware Components
•
Replacing the MX960 Craft Interface on page 307
•
Replacing an MX960 Fan Tray on page 327
•
Replacing the MX960 Air Filter on page 325
Tools and Parts Required for MX960 Router Connections
To connect the router to management devices and line cards, you need the following tools and parts:
• Phillips (+) screwdrivers, numbers 1 and 2
• 2.5-mm flat-blade (–) screwdriver
• 2.5-mm Phillips (+) screwdriver
• Wire cutters
• Electrostatic discharge (ESD) grounding wrist strap
Related
Documentation
•
Connecting the MX960 Router to a Network for Out-of-Band Management on page 248
•
Connecting the MX960 Router to a Management Console or Auxiliary Device on page 248
•
Connecting an MX960 Router to an External Alarm-Reporting Device on page 249
264 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 21
Installing Components
•
Installing the MX960 Craft Interface on page 265
•
Installing the MX960 Air Filter on page 266
•
Installing an MX960 Fan Tray on page 267
•
Installing an MX960 Routing Engine on page 269
•
Installing an MX960 DPC on page 271
•
Installing an MX960 FPC on page 275
•
Installing an MX960 MIC on page 278
•
Installing an MX960 Dual-Wide MIC on page 281
•
Installing an MX960 MPC on page 284
•
Installing an MX960 PIC on page 286
•
Installing a Cable on an MX960 DPC, MPC, MIC, or PIC on page 289
•
Installing an MX960 AC Power Supply on page 290
•
Installing an MX960 DC Power Supply on page 293
•
Installing an MX960 AS MLC on page 297
•
Installing an MX960 AS MSC on page 299
•
Installing an MX960 AS MXC on page 301
•
Installing an MX960 SCB on page 302
•
Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC on page 304
Installing the MX960 Craft Interface
To install the craft interface (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Grasp the craft interface with one hand, and hold the bottom edge of the craft interface with the other hand to support its weight.
3.
Orient the ribbon cable so that it plugs into the connector socket. The connector is keyed and can be inserted only one way.
Copyright © 2017, Juniper Networks, Inc.
265
MX960 3D Universal Edge Router Hardware Guide
4.
Align the bottom of the craft interface with the sheet metal above the card cage and press it into place.
5.
Tighten the screws on the left and right corners of the craft interface faceplate.
6.
Reattach any external devices connected to the craft interface.
Figure 90: Installing the Craft Interface
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Disconnecting the Alarm Relay Wires from the MX960 Craft Interface on page 307
•
Removing the MX960 Craft Interface on page 308
•
Connecting the Alarm Relay Wires to the MX960 Craft Interface on page 255
•
MX960 Craft Interface Overview on page 15
Installing the MX960 Air Filter
To install the air filter (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Ensure that the air filter is right side up.
3.
Place the air filter into the air filter tray.
4.
Insert the air filter tray into the chassis by sliding it straight into the chassis until it stops.
266 Copyright © 2017, Juniper Networks, Inc.
5.
Lower the cable manager back into position.
6.
Rearrange the cables in the cable manager.
Figure 91: Installing the Air Filter
Chapter 21: Installing Components
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Removing the Normal-Capacity MX960 Air Filter on page 325
•
Maintaining the MX960 Air Filter on page 446
Installing an MX960 Fan Tray
To install a fan tray (see
and
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Grasp the fan tray on each side, and insert it straight into the chassis. Note the correct orientation by the "this side up" label on the top surface of the fan tray.
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
4.
Lower the cable manager back into position, if necessary.
Copyright © 2017, Juniper Networks, Inc.
267
MX960 3D Universal Edge Router Hardware Guide
Figure 92: Installing an Upper Fan Tray
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
268 Copyright © 2017, Juniper Networks, Inc.
Figure 93: Installing a Lower Fan Tray
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
YELL
M
OK FAIL
7
ONLINE
ACO/LT
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK
FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Chapter 21: Installing Components
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Removing an MX960 Fan Tray on page 327
•
Maintaining the MX960 Fan Trays on page 446
Installing an MX960 Routing Engine
To install a Routing Engine into an SCB (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Ensure that the ejector handles are not in the locked position. If necessary, flip the ejector handles outward.
3.
Place one hand underneath the Routing Engine to support it.
4.
Carefully align the sides of the Routing Engine with the guides inside the opening on the SCB.
Copyright © 2017, Juniper Networks, Inc.
269
MX960 3D Universal Edge Router Hardware Guide
5.
Slide the Routing Engine into the SCB until you feel resistance, and then press the
Routing Engine's faceplate until it engages the connectors.
6.
Press both of the ejector handles inward to seat the Routing Engine.
7.
Tighten the captive screws on the left and right of the Routing Engine.
8.
Connect the management device cables to the Routing Engine.
The Routing Engine might require several minutes to boot.
After the Routing Engine boots, verify that it is installed correctly by checking the FAIL ,
RE0 , and RE1 LEDs on the craft interface. If the router is operational and the Routing
Engine is functioning properly, the green ONLINE LED lights steadily. If the red FAIL LED lights steadily instead, remove and install the Routing Engine again. If the red FAIL LED still lights steadily, the Routing Engine is not functioning properly. Contact your customer support representative.
To check the status of the Routing Engine, use the CLI command: user@host> show chassis routing-engine
Routing Engine status: Slot 0: Current state Master ...
For more information about using the CLI, see the Junos OS documentation.
Figure 94: Installing a Routing Engine
270
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing Connections to MX960 Routing Engine Interface Ports on page 343
•
Removing an MX960 Routing Engine on page 333
•
MX960 Routing Engine Description on page 29
Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
Installing an MX960 DPC
A DPC weighs up to 14.5 lb (6.6 kg). Be prepared to accept its full weight.
To install a DPC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place the DPC on an antistatic mat, or remove it from its electrostatic bag.
3.
Identify the slot on the router where it will be installed.
4.
Verify that each fiber-optic transceiver is covered with a rubber safety cap. If it does not, cover the transceiver with a safety cap.
5.
Orient the DPC so that the faceplate faces youvertically.
6.
Lift the DPC into place, and carefully align the sides of the DPC with the guides inside the card cage.
7.
Slide the DPC all the way into the card cage until you feel resistance.
8.
Grasp both ejector handles, and rotate them clockwise simultaneously until the DPC is fully seated.
9.
Remove the rubber safety cap from each fiber-optic transceiver and cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
10.
Insert the cables into the cable connector ports on each DPC (see
).
11.
Arrange the cable in the standard or extended cable manager to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.
Copyright © 2017, Juniper Networks, Inc.
271
MX960 3D Universal Edge Router Hardware Guide
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
12.
Use one of the following methods to bring the DPC online:
• Press and hold the corresponding DPC online button on the craft interface until the green OK LED next to the button lights steadily, in about 5 seconds.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer .
CAUTION: After the OK LED turns green, wait at least 30 seconds before removing the DPC again, removing a DPC from a different slot, or inserting a DPC in a different slot.
You can also verify that the DPC is functioning correctly by issuing the show chassis fpc and show chassis fpc pic-status commands.
272 Copyright © 2017, Juniper Networks, Inc.
Figure 95: Installing a DPC
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
YELL M
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
0/0 0/5
OK/FAIL
2/0 2/5
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1/0 1/5
3/0 3/5
Chapter 21: Installing Components
Copyright © 2017, Juniper Networks, Inc.
273
MX960 3D Universal Edge Router Hardware Guide
Figure 96: Attaching a Cable to a DPC
274
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Holding an MX960 DPC on page 452
•
Storing an MX960 DPC on page 454
• MX960 DPC Terminology
•
Removing an MX960 DPC on page 355
•
Maintaining MX960 DPCs on page 450
•
Troubleshooting the MX960 DPCs on page 490
Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
Installing an MX960 FPC
An FPC takes up two DPC slots on the MX960 router. Up to six FPCs can be installed vertically in the front of the router. The FPCs are hot-insertable and hot-removable. An empty FPC3 weighs 14 lb (6.5 kg). A fully configured FPC can weigh up to 18 lb (8.2 kg).
Be prepared to accept its full weight.
To install an FPC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place the FPC on an antistatic mat.
3.
Take each PIC to be installed in the replacement FPC out of its electrostatic bag, and identify the slot on the FPC where it will be connected.
4.
Verify that each fiber-optic PIC has a rubber safety cap covering the PIC transceiver.
If it does not, cover the transceiver with a safety cap.
5.
Install each PIC into the appropriate slot on the FPC.
6.
Locate the two slots in the card cage in which you plan to install the FPC.
7.
Orient the FPC so that the faceplate faces you.
8.
Lift the FPC into place, and carefully align the sides of the FPC with the guides inside the card cage.
CAUTION: When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
9.
Slide the FPC all the way into the card cage until you feel resistance.
10.
Grasp both ejector handles, and rotate them clockwise simultaneously until the FPC is fully seated.
11.
If any of the PICs on the FPC connect to fiber-optic cable, remove the rubber safety cap from each transceiver and cable.
Copyright © 2017, Juniper Networks, Inc.
275
MX960 3D Universal Edge Router Hardware Guide
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
12.
Insert the appropriate cable into the cable connector ports on each PIC on the FPC.
13.
Arrange the cable in the standard or extended cable manager to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
14.
Use one of the following methods to bring the FPC online:
• Press and hold the FPC online/offline button until the green OK LED next to the button lights steadily, in about 5 seconds. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer .
CAUTION: After the OK LED lights steadily, wait at least 30 seconds before removing the FPC again, removing an FPC from a different slot, or inserting an FPC in a different slot.
You can also verify correct FPC and PIC functioning by issuing the show chassis fpc and show chassis fpc pic-status commands described in
“Maintaining MX960 FPCs” on page 455
and
“Maintaining MX960 PICs” on page 466
.
276 Copyright © 2017, Juniper Networks, Inc.
Figure 97: Installing an FPC
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ALAR M
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Chapter 21: Installing Components
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Installing an MX960 PIC on page 286
•
Removing an MX960 FPC on page 361
•
Maintaining MX960 FPCs on page 455
•
Holding an MX960 FPC on page 457
•
Storing an MX960 FPC on page 461
Copyright © 2017, Juniper Networks, Inc.
277
MX960 3D Universal Edge Router Hardware Guide
Installing an MX960 MIC
To install a MIC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
If you have used a dual-wide MIC and are now replacing it with two “single” MICs, install the septum (see
a.
Place the MPC on a flat surface (if necessary, remove the MPC from the router as described in
“Removing an MX960 MPC” on page 377 ).
b.
Position the septum in the center of the MPC so that it lines up with holes labeled
S on the top of the MPC.
c.
Insert a screw into each of the two holes labeled S , and then tighten completely.
d.
On the bottom of the MPC, insert a screw into each of the four holes labeled S , and then tighten completely.
e.
Install the MPC as described in
“Installing an MX960 MPC” on page 284 .
Figure 98: Installing the Septum
Slide septum into MPC.
Install two screws.
Install four screws on bottom.
278
3.
If the MIC uses fiber-optic cable, verify that a rubber safety cap is over each transceiver on the faceplate. Install a cap if necessary.
4.
On the MPC, pull the ejector lever that is adjacent to the MIC you are installing away from the MPC faceplate.
5.
Align the rear of the MIC with the guides located at the corners of the MIC slot.
6.
Slide the MIC into the MPC until it is firmly seated in the MPC.
Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
CAUTION: Slide the MIC straight into the slot to avoid damaging the components on the MIC.
7.
Verify that the ejector lever is engaged by pushing it towards the MPC faceplate.
8.
If the MIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
9.
Insert the appropriate cables into the cable connectors on the MIC.
10.
Arrange each cable to prevent the cable from dislodging or developing stress points.
Secure the cable so that it is not supporting its own weight as it hangs to the floor.
Place excess cable out of the way in a neatly coiled loop.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
11.
Use one of the following methods to bring the MIC online:
• Press its online/offline button. Use a narrow-ended tool that fits inside the opening that leads to the button. Press the button until the MIC OK/FAIL LED lights green.
• Issue the following CLI command: user@host> request chassis mic fpc-slot mpc-slot mic-slot mic-slot online
For more information about the command, see the CLI Explorer .
Copyright © 2017, Juniper Networks, Inc.
279
MX960 3D Universal Edge Router Hardware Guide
The normal functioning status LED confirms that the MIC is online. You can also verify correct MIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining MX960 MICs” on page 462
.
Figure 99: Installing a MIC
280
Related
Documentation
•
MX960 Modular Interface Card Description on page 82
•
Maintaining MX960 MICs on page 462
•
Troubleshooting the MX960 MICs on page 495
•
Removing an MX960 MPC on page 377
•
Removing an MX960 MIC on page 367
• Preventing Electrostatic Discharge Damage to an MX960 Router
Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
Installing an MX960 Dual-Wide MIC
To install a dual-wide MIC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Remove the septum, if necessary (see
a.
Place the MPC on a flat surface (if necessary, remove the MPC from the router as described in
“Removing an MX960 MPC” on page 377 ).
b.
Remove the four screws labeled S on the bottom of the MPC.
c.
Remove the two screws labeled S on the top of the MPC.
d.
Slide the septum towards you and out of the MPC.
e.
Store the septum and screws for later use.
f.
Install the MPC as described in
“Installing an MX960 MPC” on page 284 .
Figure 100: Removing the Septum
Remove four screws on bottom.
Remove two screws on top.
Slide septum forward.
MPC
3.
If the MIC uses fiber-optic cable, verify that a rubber safety cap is over each transceiver on the faceplate. Install a cap if necessary.
4.
Pull the ejector lever above both MIC slots away from the router.
5.
Align the rear of the MIC with the guides located at the corners of the MIC slot.
6.
Slide the MIC into the MIC slot until it is firmly seated in the chassis.
Copyright © 2017, Juniper Networks, Inc.
281
MX960 3D Universal Edge Router Hardware Guide
282
CAUTION: Slide the MIC straight into the slot to avoid damaging the components on the MIC.
7.
Verify that the ejector levers are engaged by pushing them toward the router.
8.
If the MIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
9.
Insert the appropriate cables into the cable connectors on the MIC.
10.
Arrange each cable to prevent the cable from dislodging or developing stress points.
Secure the cable so that it is not supporting its own weight as it hangs to the floor.
Place excess cable out of the way in a neatly coiled loop.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
11.
Use one of the following methods to bring the MIC online:
• Press its online/offline button. Use a narrow-ended tool that fits inside the opening that leads to the button. Press the button until the MIC OK/FAIL LED lights green.
• Issue the following CLI command: user@host> request chassis mic fpc-slot mpc-slot mic-slot mic-slot online
Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
The normal functioning status LED confirms that the MIC is online. You can also verify correct MIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining MX960 MICs” on page 462
.
Figure 101: Installing a Dual-Wide MIC
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
FAN
0
1
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK
FAIL
0
ONLINE
1
ONLINE
OK
FAIL
2 6
ONLINE
OK
FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK FAIL
NC C
NO NC
OK FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK
FAIL
11
ONLINE
Dual-wide MIC
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Related
Documentation
•
MX960 Modular Interface Card Description on page 82
•
Maintaining MX960 MICs on page 462
•
Troubleshooting the MX960 MICs on page 495
•
Removing an MX960 MPC on page 377
•
Removing an MX960 MIC on page 367
• Preventing Electrostatic Discharge Damage to an MX960 Router
Copyright © 2017, Juniper Networks, Inc.
283
MX960 3D Universal Edge Router Hardware Guide
Installing an MX960 MPC
An MPC installs vertically in the front of the router. The MPCs are hot-insertable and hot-removable. A fully configured MPC can weigh up to 18.35 lb (8.3 kg). Be prepared to accept its full weight.
To install an MPC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place the MPC on an antistatic mat.
3.
Take each MIC to be installed in the replacement MPC out of its electrostatic bag, and identify the slot on the MPC where it will be connected.
4.
Verify that each fiber-optic MIC has a rubber safety cap covering the MIC transceiver.
If it does not, cover the transceiver with a safety cap.
5.
Install each MIC into the appropriate slot on the MPC.
6.
Locate the slot in the card cage in which you plan to install the MPC.
7.
Orient the MPC so that the faceplate faces you.
8.
Lift the MPC into place, and carefully align the sides of the MPC with the guides inside the card cage.
CAUTION: When the MPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
9.
Slide the MPC all the way into the card cage until you feel resistance.
10.
Grasp both ejector handles, and rotate them clockwise simultaneously until the MPC is fully seated.
11.
If any of the MICs on the MPC connect to fiber-optic cable, remove the rubber safety cap from each transceiver and cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
284 Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
12.
Insert the appropriate cable into the cable connector ports on each MIC on the MPC.
Secure the cables so that they are not supporting their own weight. Place excess cable out of the way in a neatly coiled loop, using the cable management system. Placing fasteners on a loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
13.
Use one of the following methods to bring the MPC online:
• Press and hold the corresponding MPC online button on the craft interface until the green OK/FAIL LED next to the button lights steadily, in about 5 seconds.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer .
CAUTION: After the OK/FAIL LED lights steadily, wait at least 30 seconds before removing the MPC again, removing an MPC from a different slot, or inserting an MPC in a different slot.
You can also verify correct MPC and MIC functioning by issuing the show chassis fpc and show chassis fpc pic-status commands described in
“Maintaining MX960 MPCs” on page 463
and
“Maintaining MX960 MICs” on page 462
.
Copyright © 2017, Juniper Networks, Inc.
285
MX960 3D Universal Edge Router Hardware Guide
Figure 102: Installing an MPC
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK
FAIL
0
ONLINE
1
ONLINE
OK
FAIL
2 6
ONLINE
OK
FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK
FAIL
NC C
NO NC
OK FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK
FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
MX960 Modular Port Concentrator Description on page 89
•
Removing an MX960 MPC on page 377
•
Installing an MX960 MIC on page 278 .
•
Maintaining MX960 MPCs on page 463
•
Troubleshooting the MX960 MPCs on page 496
Installing an MX960 PIC
To install a PIC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
If the PIC uses fiber-optic cable, verify that a rubber safety cap is over each transceiver on the faceplate. Install a cap if necessary.
286 Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
3.
Align the notches in the connector at the rear of the PIC with the notches in the PIC slot in the FPC and then slide the PIC in until it lodges firmly in the FPC.
CAUTION: Slide the PIC straight into the slot to avoid damaging the components on the bottom of the PIC.
4.
For an FPC3 PIC, turn the ejector handle at the top of the PIC faceplate clockwise, then tighten the captive screw at the bottom of the faceplate to secure the PIC in the
FPC.
5.
If the PIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Insert the appropriate cables into the cable connectors on the PIC.
7.
Arrange the cable in the standard or extended cable manager to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
8.
Use one of the following methods to bring the PIC online:
• Press the PIC offline/online button until the PIC LED lights green. For a PIC installed in FPC3, use a narrow-ended tool that fits inside the opening that leads to the button.
Copyright © 2017, Juniper Networks, Inc.
287
MX960 3D Universal Edge Router Hardware Guide
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning status LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining MX960 PICs” on page 466 .
Figure 103: Installing a PIC
288
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Removing an MX960 PIC on page 382
•
Troubleshooting the MX960 PICs on page 494
•
Maintaining MX960 PICs on page 466
•
MX960 PIC Serial Number Label on page 516
•
MX960 PIC Description on page 66
Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
Installing a Cable on an MX960 DPC, MPC, MIC, or PIC
To install a cable:
1.
Have ready a length of the type of cable used by the component. For cable specifications, see the MX Series Interface Module Reference .
2.
If the cable connector port is covered by a rubber safety cap, remove the cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the component faceplate.
4.
Arrange the cable in the standard or extended cable manager to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
5.
Insert the other end of the cable into the destination port.
6.
Repeat the previous steps for any additional cables.
7.
If the component is offline (its failure indicator LED is lit), use one of the following methods to bring it online.
• To bring a DPC or MPC online:
Copyright © 2017, Juniper Networks, Inc.
289
MX960 3D Universal Edge Router Hardware Guide
• Press and hold the corresponding online button on the craft interface until the green OK LED next to the button lights steadily, in about 5 seconds.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer .
• To bring a PIC online:
• Press the PIC offline/online button until the PIC LED lights green. For a PIC installed in FPC3, use a narrow-ended tool that fits inside the opening that leads to the button.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
• To bring a MIC online:
• Press the MIC offline/online button until the MIC LED lights green.
• Issue the following CLI command: user@host> request chassis mic fpc-slot mpc-slot pic-slot mic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning indicator LED confirms that the component is online. You can also verify correct DPC or MPC functioning by issuing the show chassis fpc command or the correct PIC or MIC functioning by issuing the show chassis fpc pic-status command.
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Removing a Cable on an MX960 DPC, MPC, MIC, or PIC on page 386
•
Maintaining Cables That Connect to MX960 DPCs, MPCs, MICs, or PICs on page 466
Installing an MX960 AC Power Supply
To install an AC power supply (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Move the AC input switch in the chassis above the empty power supply slot to the off
( O ) position.
290 Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
3.
Ensure that the release lever below the empty power supply slot is locked in the counterclockwise position (see
).
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
4.
Using both hands, slide the power supply straight into the chassis until the power supply is fully seated in the chassis slot. The power supply faceplate should be flush with any adjacent power supply faceplates.
The small tab on the metal housing that is controlled by the release lever must be inside of the corresponding slot at the bottom of the power supply (see
). This tab is used to pull the power supply down in the chassis slot, prior to removing the power supply.
5.
While firmly pushing the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever clockwise until it stops.
6.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
7.
Move the AC input switch in the chassis above the power supply to the on ( — ) position and observe the status LEDs on the power supply faceplate. If the power supply is correctly installed and functioning normally, the AC OK and DC OK LEDs light steadily, and the PS FAIL LED is not lit.
Copyright © 2017, Juniper Networks, Inc.
291
MX960 3D Universal Edge Router Hardware Guide
Figure 104: Installing an AC Power Supply
292
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
MX960 AC Power Supply Description on page 98
• MX960 AC Power Electrical Safety Guidelines and Warnings
•
Removing a Normal Capacity MX960 AC Power Supply on page 391
•
Connecting an MX960 AC Power Supply Cord on page 243
•
Disconnecting an MX960 AC Power Supply Cord on page 403
Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
Installing an MX960 DC Power Supply
WARNING: Before performing DC power procedures, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.
To install a DC power supply (see
1.
Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Move the DC circuit breaker on the power supply faceplate to the off ( O ) position.
4.
Ensure that the release lever below the empty power supply slot is locked in the counterclockwise position (see
).
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
5.
Using both hands, slide the power supply straight into the chassis until the power supply is fully seated in the chassis slot. The power supply faceplate should be flush with any adjacent power supply faceplates.
The small tab on the metal housing that is controlled by the release lever must be inside of the corresponding slot at the bottom of the power supply (see
). This tab is used to pull the power supply down in the chassis slot, prior to removing the power supply.
6.
While firmly pushing the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever clockwise until it stops.
7.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
8.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
9.
Remove the nut and washer from each of the terminal studs.
Copyright © 2017, Juniper Networks, Inc.
293
MX960 3D Universal Edge Router Hardware Guide
10.
Secure each power cable lug to the terminal studs, first with the split washer, then with the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut (see
). Do not overtighten the nut. (Use a
7/16-in. (11 mm) torque-controlled driver or socket wrench.) a. Attach the positive (+) DC source power cable lug to the RTN (return) terminal.
b. Attach the negative (–) DC source power cable lug to the –48V (input) terminal.
CAUTION: Ensure that each power cable lug seats flush against the surface of the terminal block as you are tightening the nuts. Ensure that each nut is properly threaded onto the terminal stud. The nut should be able to spin freely with your fingers when it is first placed onto the terminal stud.
Applying installation torque to the nut when improperly threaded may result in damage to the terminal stud.
CAUTION: The maximum torque rating of the terminal studs on the DC power supply is 58 lb-in. (6.5 Nm). The terminal studs may be damaged if excessive torque is applied. Use only a torque-controlled driver or socket wrench to tighten nuts on the DC power supply terminal studs.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
NOTE: The DC power supplies in slots PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A , and the DC power supplies in PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B . This configuration provides the commonly deployed A/B feed redundancy for the system. For information about connecting to DC power sources, see
“Electrical Specifications for the MX960 DC Power Supply” on page 169 .
11.
Loosen the captive screw on the cable restraint on the lower edge of the power supply faceplate.
12.
Route the positive and negative DC power cables through the left and right sides of the cable restraint.
294 Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
13.
Tighten the cable restraint captive screw to hold the power cables in place.
WARNING: Once the DC power supply is connected, the cable will be blocking the PEM slot label. Make sure and note or mark the PEM slot once the power supply is connected.
14.
Replace the clear plastic cover over the terminal studs on the faceplate.
15.
Verify that the power cabling is correct, that the cables are not touching, and that they do not block access to router components or drape where people could trip on them.
16.
Switch on the dedicated customer site circuit breaker.
17.
Verify that the INPUT OK LED on the power supply is lit steadily.
18.
On each of the DC power supplies, switch the DC circuit breaker to the center position before moving it to the on ( | ) position.
NOTE: The circuit breaker may bounce back to the off ( O ) position if you move the breaker too quickly.
19.
Verify that the BREAKER ON LED is lit steadily.
20.
Verify that the PWR OK LED is lit steadily.
Copyright © 2017, Juniper Networks, Inc.
295
MX960 3D Universal Edge Router Hardware Guide
Figure 105: Installing a DC Power Supply
296 Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
Figure 106: Connecting DC Power to the MX960 Router
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
MX960 DC Power Supply on page 104
• MX960 DC Power Electrical Safety Guidelines
•
Removing an MX960 DC Power Supply on page 395
•
Connecting an MX960 DC Power Supply Cable on page 244
•
Disconnecting an MX960 DC Power Supply Cable on page 405
Installing an MX960 AS MLC
You can install up to eight Application Services Modular Line Cards (AS MLCs) vertically in the front of the MX960 router. The AS MLCs are hot-insertable and hot-removable.
An empty AS MLC weighs 10.5 lb (4.76 kg). A fully configured AS MLC can weigh up to
15.27 lb (6.93 kg). Be prepared to accept its full weight.
To install an AS MLC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place the AS MLC on an antistatic mat.
Copyright © 2017, Juniper Networks, Inc.
297
MX960 3D Universal Edge Router Hardware Guide
3.
Take the AS MSC and AS MXC (the modular cards) to be installed in the AS MLC out of its electrostatic bag. The AS MSC must be inserted in the top slot and the AS MXC in the bottom slot.
4.
Install the AS MSC and AS MXC into the appropriate slot on the AS MLC.
5.
Locate the slots in the card cage in which you plan to install the AS MLC.
6.
Orient the AS MLC so that the faceplate faces you.
7.
Lift the AS MLC into place, and carefully align the sides of the AS MLC with the guides inside the card cage.
CAUTION: When the AS MLC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
8.
Slide the AS MLC all the way into the card cage until you feel resistance.
9.
Grasp both ejector handles, and rotate them clockwise simultaneously until the AS
MLC is fully seated.
10.
Use one of the following methods to bring the AS MLC online:
• Press and hold the AS MLC online/offline button until the green OK LED next to the button lights steadily, in about 5 seconds. The LEDs and online/offline button for each AS MLC are located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer .
CAUTION: After the OK LED lights steadily, wait at least 30 seconds before removing the AS MLC again, removing an AS MLC from a different slot, or inserting an AS MLC in a different slot.
You can also verify correct AS MLC and AS MSC or AS MXC functioning by issuing the show chassis fpc and show chassis fpc pic-status .
298 Copyright © 2017, Juniper Networks, Inc.
Figure 107: Installing an AS MLC
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK
FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELLOWALARM
REDALARM
OK FAIL
NC C NO NC
C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Chapter 21: Installing Components
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Installing an MX960 AS MSC on page 299
•
Installing an MX960 AS MXC on page 301
•
Removing an MX960 AS MLC on page 313
Installing an MX960 AS MSC
To install an AS MSC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Align the notches in the connector at the rear of the AS MSC with the notches in the
AS MSC slot (slot 0 —the top slot in the AS MLC ), and then slide the AS MSC in until it lodges firmly in the AS MLC.
Copyright © 2017, Juniper Networks, Inc.
299
MX960 3D Universal Edge Router Hardware Guide
CAUTION: Slide the AS MSC straight into the slot to avoid damaging the components on the bottom of the AS MSC.
3.
Use one of the following methods to bring the AS MSC online:
• Press the AS MSC offline/online button until the LED light turns green.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning status LED confirms that the AS MSC is online. You can also verify correct AS MSC functioning by issuing the show chassis fpc pic-status .
Figure 108: Installing an AS MSC
300
Related
Documentation
• MX480 Application Services Modular Storage Card Description
• Removing an MX480 AS MSC
Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
Installing an MX960 AS MXC
To install an AS MXC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Align the notches in the connector at the rear of the AS MXC with the notches in the
AS MXC slot (slot 1—the bottom slot in the AS MLC), and then slide the AS MXC in until it lodges firmly in the AS MLC.
CAUTION: Slide the AS MXC straight into the slot to avoid damaging the components on the bottom of the AS MXC.
3.
Use one of the following methods to bring the AS MXC online:
• Press the AS MXC offline/online button until the LED light turns green.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning status LED confirms that the AS MXC is online. You can also verify correct AS MXC functioning by issuing the show chassis fpc pic-status command.
Copyright © 2017, Juniper Networks, Inc.
301
MX960 3D Universal Edge Router Hardware Guide
Figure 109: Installing an AS MXC
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
MX960 Application Services Modular Processing Card Description on page 73
•
Removing an MX960 AS MXC on page 321
Installing an MX960 SCB
To install an SCB (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Carefully align the sides of the SCB with the guides inside the chassis.
3.
Slide the SCB into the chassis until you feel resistance, carefully ensuring that it is correctly aligned.
4.
Grasp both ejector handles, and rotate them simultaneously clockwise until the SCB is fully seated.
302 Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
5.
Place the ejector handles in the proper position, vertically and toward the center of the board.
6.
Check the LEDs on the SCB faceplate to verify that it is functioning normally.
• The green OK/FAIL LED should light steadily a few minutes after the SCB is installed.
• If the OK/FAIL LED is red, remove and install the SCB again. If the OK/FAIL LED still lights steadily, the SCB is not functioning properly. Contact your customer support representative.
7.
Check the status of the SCB using the show chassis environment cb command: user@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 25 degrees C / 77 degrees F
Power 1
1.2 V 1198 mV
1.5 V 1508 mV
1.8 V 1830 mV
2.5 V 5059 mV
3.3 V 6593 mV
5.0 V 5111 mV
12.0 V 12181 mV
1.25 V 1250 mV
3.3 V SM3 6587 mV
5 V RE 5078 mV
12 V RE 12026 mV
Power 2
11.3 V bias PEM 11253 mV
4.6 V bias MidPlane 4827 mV
11.3 V bias FPD 11408 mV
11.3 V bias POE 0 11446 mV
11.3 V bias POE 1 11408 mV
Bus Revision 6
FPGA Revision 0
CB 1 status:
State Online Standby
Temperature 26 degrees C / 78 degrees F
Power 1
1.2 V 1211 mV
1.5 V 1517 mV
1.8 V 1817 mV
2.5 V 2507 mV
3.3 V 3312 mV
5.0 V 5136 mV
12.0 V 12142 mV
1.25 V 1260 mV
3.3 V SM3 3306 mV
5 V RE 5085 mV
12 V RE 11968 mV
Power 2
11.3 V bias PEM 11369 mV
4.6 V bias MidPlane 4814 mV
11.3 V bias FPD 11427 mV
11.3 V bias POE 0 11350 mV
11.3 V bias POE 1 11330 mV
Bus Revision 39
FPGA Revision 1
Copyright © 2017, Juniper Networks, Inc.
303
MX960 3D Universal Edge Router Hardware Guide
Figure 110: Installing an SCB
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
• Operating and Positioning the MX960 SCB Ejectors
•
Removing an MX960 SCB on page 410
Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC
To install an SFP or XFP:
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Take each transceiver to be installed out of its electrostatic bag, and identify the slot on the component where it will be installed.
3.
Verify that each transceiver is covered by a rubber safety cap. If it is not, cover the transceiver with a safety cap.
304 Copyright © 2017, Juniper Networks, Inc.
Chapter 21: Installing Components
4.
Carefully align the transceiver with the slots in the component. The connectors should face the component.
5.
Slide the transceiver until the connector is seated in the component slot. If you are unable to fully insert the transceiver, make sure the connector is facing the right way.
6.
Close the ejector handle of the transceiver.
7.
Remove the rubber safety cap from the transceiver and the end of the cable. Insert the cable into the transceiver.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
8.
Verify that the status LEDs on the component faceplate indicate that the SFP or XFP is functioning correctly. For more information about the component LEDs, see the MX
Series Interface Module Reference .
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Removing an SFP or XFP Transceiver from an MX960 DPC, MPC, MIC, or PIC on page 437
•
Replacing an MX960 PIC on page 382
•
Replacing an MX960 DPC on page 355
Copyright © 2017, Juniper Networks, Inc.
305
MX960 3D Universal Edge Router Hardware Guide
306 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 22
Replacing Chassis Components
•
Replacing the MX960 Craft Interface on page 307
•
Replacing the MX960 Cable Manager on page 310
•
Replacing the Console or Auxiliary Cable on an MX960 Router on page 311
•
Replacing the Management Ethernet Cable on an MX Series Router on page 312
•
Replacing an MX960 AS MLC on page 313
•
Replacing an MX960 AS MSC on page 318
•
Replacing an MX960 AS MXC on page 320
Replacing the MX960 Craft Interface
1.
Disconnecting the Alarm Relay Wires from the MX960 Craft Interface on page 307
2.
Removing the MX960 Craft Interface on page 308
3.
Installing the MX960 Craft Interface on page 308
4.
Connecting the Alarm Relay Wires to the MX960 Craft Interface on page 309
Disconnecting the Alarm Relay Wires from the MX960 Craft Interface
To disconnect the alarm relay wires from the router and an alarm-reporting device (see
1.
Disconnect the existing wire at the external device.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Using a 2.5-mm flat-blade screwdriver, loosen the small screws on the face of the terminal block and remove the block from the relay contact.
4.
Using the 2.5-mm flat-blade screwdriver, loosen the small screws on the side of the terminal block. Remove existing wires from the slots in the front of the block.
Copyright © 2017, Juniper Networks, Inc.
307
MX960 3D Universal Edge Router Hardware Guide
Figure 111: Alarm Relay Contacts
Removing the MX960 Craft Interface
To remove the craft interface (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Detach any external devices connected to the craft interface.
3.
Loosen the captive screws at the left and right corners of the craft interface faceplate.
4.
Grasp the craft interface faceplate and carefully tilt it toward you until it is horizontal.
5.
Disconnect the ribbon cable from the back of the faceplate by gently pressing on both sides of the latch with your thumb and forefinger. Remove the craft interface from the chassis.
Figure 112: Removing the Craft Interface
Installing the MX960 Craft Interface
To install the craft interface (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Grasp the craft interface with one hand, and hold the bottom edge of the craft interface with the other hand to support its weight.
308 Copyright © 2017, Juniper Networks, Inc.
Chapter 22: Replacing Chassis Components
3.
Orient the ribbon cable so that it plugs into the connector socket. The connector is keyed and can be inserted only one way.
4.
Align the bottom of the craft interface with the sheet metal above the card cage and press it into place.
5.
Tighten the screws on the left and right corners of the craft interface faceplate.
6.
Reattach any external devices connected to the craft interface.
Figure 113: Installing the Craft Interface
Connecting the Alarm Relay Wires to the MX960 Craft Interface
To connect the alarm relay wires between a router and an alarm-reporting device (see
):
1.
Prepare the required length of replacement wire with gauge between 28-AWG and
14-AWG (0.08 and 2.08 mm
2
).
2.
Insert the replacement wires into the slots in the front of the block. Use a 2.5-mm flat-blade screwdriver to tighten the screws and secure the wire.
3.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
4.
Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
5.
Attach the other end of the wires to the external device.
Copyright © 2017, Juniper Networks, Inc.
309
MX960 3D Universal Edge Router Hardware Guide
Figure 114: Alarm Relay Contacts
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
MX960 Craft Interface Overview on page 15
•
MX960 Craft Interface Serial Number Label on page 511
Replacing the MX960 Cable Manager
To remove the standard cable manager (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Using a 7/16-in. (11 mm) nut driver, unscrew the nuts on the corners of the standard cable manager.
3.
Grasp the bottom of the standard cable manager, and pull it straight out from the studs on the front of the chassis.
310 Copyright © 2017, Juniper Networks, Inc.
Chapter 22: Replacing Chassis Components
Figure 115: Removing the Standard Cable Manager
To install the standard cable manager (see
):
1.
Position the standard cable manager on the studs on the lower front of the chassis.
2.
Insert the nuts on the corners in the standard cable manager onto the studs on the chassis.
3.
Using a 7/16-in. (11 mm) nut driver, tighten the nuts securely.
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
MX960 Cable Manager Description on page 19
•
Verifying the Version of the MX960 Cable Manager on page 469
Replacing the Console or Auxiliary Cable on an MX960 Router
To use a system console to configure and manage the Routing Engine, connect it to the
CONSOLE port on the Routing Engine. To use a laptop, modem, or other auxiliary device, connect it to the AUX port on the Routing Engine. Both ports accept a cable with an RJ-45
Copyright © 2017, Juniper Networks, Inc.
311
MX960 3D Universal Edge Router Hardware Guide connector. One RJ-45/DB-9 cable is provided with the router. If you want to connect a device to both ports, you must supply another cable.
To replace a cable connected to a management console or auxiliary device:
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Press the tab on the connector, and pull the connector straight out of the port.
3.
Disconnect the cable from the console or auxiliary device.
4.
Plug the RJ-45 end of the replacement serial cable into the CONSOLE or AUX port.
shows the external device ports on the Routing Engine.
5.
Plug the female DB-9 end into the console or auxiliary device's serial port.
Figure 116: Auxiliary and Console Ports
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing the Management Ethernet Cable on an MX Series Router on page 312
•
Routing Engine Interface Cable and Wire Specifications for MX Series Routers on page 142
•
Replacing an MX960 Routing Engine on page 333
Replacing the Management Ethernet Cable on an MX Series Router
One Ethernet cable with RJ-45 connectors is provided with the router. To replace the cable connected to the ETHERNET port:
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Press the tab on the connector, and pull the connector straight out of the port.
shows the connector.
3.
Disconnect the cable from the network device.
312 Copyright © 2017, Juniper Networks, Inc.
Chapter 22: Replacing Chassis Components
4.
Plug one end of the replacement cable into the ETHERNET port.
shows the port.
5.
Plug the other end of the cable into the network device.
Figure 117: Cable Connector
Figure 118: Ethernet Port
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Routing Engine Interface Cable and Wire Specifications for MX Series Routers on page 142
•
Replacing the Console or Auxiliary Cable on an MX960 Router on page 311
•
Replacing an MX960 Routing Engine on page 333
Replacing an MX960 AS MLC
1.
Removing an MX960 AS MLC on page 313
2.
Installing an MX960 AS MLC on page 316
Removing an MX960 AS MLC
When you remove an Application Services Modular Line Card (AS MLC), the router continues to function, although the modular cards (AS MXC and AS MSC) installed on the AS MLC being removed no longer function.
Up to eight AS MLCs can be installed vertically in the front of the MX960 router. The AS
MLCs are hot-insertable and hot-removable. An empty AS MLC weighs 10.5 lb (4.76 kg).
A fully configured AS MLC can weigh up to 15.27 lb (6.93 kg). Be prepared to accept its full weight.
Copyright © 2017, Juniper Networks, Inc.
313
MX960 3D Universal Edge Router Hardware Guide
To remove an AS MLC (See
1.
Have ready a replacement AS MLC or an AS MLC blank panel and an antistatic mat for the AS MLC.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Use one of the following methods to take the AS MLC offline:
• Press and hold the AS MLC online/offline button. The green OK LED next to the button begins to blink. Hold the button down until the LED goes out. The online/offline button for each AS MLC is located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number offline
For more information about the command, see the CLI Explorer .
NOTE: The slot number corresponds to the lowest numbered slot for which the AS MLC is installed.
4.
Simultaneously turn both the ejector handles counterclockwise to unseat the AS MLC.
5.
Grasp the handles, and slide the AS MLC straight out of the card cage halfway.
6.
Place one hand around the front of the AS MLC (the modular card housing) and the other hand under it to support it. Slide the AS MLC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the AS MLC is concentrated in the back end. Be prepared to accept the full weight—up to 15.27 lb (6.93 kg)—as you slide the AS MLC out of the chassis.
When the AS MLC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
Do not stack AS MLCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
7.
If necessary, remove each installed AS MSC and AS MXC from the AS MLC.
314 Copyright © 2017, Juniper Networks, Inc.
Chapter 22: Replacing Chassis Components
8.
After you remove each modular card, immediately place it on an antistatic mat or in an electrostatic bag.
9.
If you are not reinstalling an AS MLC into the emptied slots within a short time, install a blank AS MLC panel over each slot to maintain proper airflow in the card cage.
CAUTION: After removing an AS MLC from the chassis, wait at least 30 seconds before reinserting it or inserting an AS MLC into a different slot.
Figure 119: Removing an AS MLC
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK
FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELLOWALARM
REDALARM
OK
FAIL
NC C NO
NC
OK FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Copyright © 2017, Juniper Networks, Inc.
315
MX960 3D Universal Edge Router Hardware Guide
Installing an MX960 AS MLC
You can install up to eight Application Services Modular Line Cards (AS MLCs) vertically in the front of the MX960 router. The AS MLCs are hot-insertable and hot-removable.
An empty AS MLC weighs 10.5 lb (4.76 kg). A fully configured AS MLC can weigh up to
15.27 lb (6.93 kg). Be prepared to accept its full weight.
To install an AS MLC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place the AS MLC on an antistatic mat.
3.
Take the AS MSC and AS MXC (the modular cards) to be installed in the AS MLC out of its electrostatic bag. The AS MSC must be inserted in the top slot and the AS MXC in the bottom slot.
4.
Install the AS MSC and AS MXC into the appropriate slot on the AS MLC.
5.
Locate the slots in the card cage in which you plan to install the AS MLC.
6.
Orient the AS MLC so that the faceplate faces you.
7.
Lift the AS MLC into place, and carefully align the sides of the AS MLC with the guides inside the card cage.
CAUTION: When the AS MLC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
8.
Slide the AS MLC all the way into the card cage until you feel resistance.
9.
Grasp both ejector handles, and rotate them clockwise simultaneously until the AS
MLC is fully seated.
10.
Use one of the following methods to bring the AS MLC online:
• Press and hold the AS MLC online/offline button until the green OK LED next to the button lights steadily, in about 5 seconds. The LEDs and online/offline button for each AS MLC are located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
316 Copyright © 2017, Juniper Networks, Inc.
Chapter 22: Replacing Chassis Components
For more information about the command, see the CLI Explorer .
CAUTION: After the OK LED lights steadily, wait at least 30 seconds before removing the AS MLC again, removing an AS MLC from a different slot, or inserting an AS MLC in a different slot.
You can also verify correct AS MLC and AS MSC or AS MXC functioning by issuing the show chassis fpc and show chassis fpc pic-status .
Figure 120: Installing an AS MLC
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK
FAIL OK
FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK
FAIL
5
ONLINE
RE0
OK
FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELLOWALARM
REDALARM
OK FAIL
NC C NO NC
C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing an MX960 AS MSC on page 318
•
Replacing an MX960 AS MXC on page 320
Copyright © 2017, Juniper Networks, Inc.
317
MX960 3D Universal Edge Router Hardware Guide
Replacing an MX960 AS MSC
1.
Removing an MX960 AS MSC on page 318
2.
Installing an MX960 AS MSC on page 319
Removing an MX960 AS MSC
AS MSCs are hot-insertable and hot-removable. When you remove an AS MSC, the router continues to function.
The AS MSCs are located in the AS MLCs installed in the front of the router. An AS MSC weighs 1.4 lb (0.6 kg).
To remove an AS MSC (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the AS
MSC.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Use one of the following methods to take the AS MSC offline:
• Press its online/offline button. Use a narrow-ended tool that fits inside the opening that leads to the button. Press and hold the button until the AS MSC LED goes out
(about 5 seconds).
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see the CLI Explorer .
4.
Slide the AS MSC out of the AS MLC card carrier by pulling the handles, and place it in the electrostatic bag or on the antistatic mat.
5.
If you are not reinstalling an AS MSC into the emptied AS MSC slot within a short time, install a blank AS MSC panel over the slot to maintain proper airflow in the AS MLC card cage.
318 Copyright © 2017, Juniper Networks, Inc.
Figure 121: Removing an AS MSC
Chapter 22: Replacing Chassis Components
Installing an MX960 AS MSC
To install an AS MSC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Align the notches in the connector at the rear of the AS MSC with the notches in the
AS MSC slot (slot 0 —the top slot in the AS MLC ), and then slide the AS MSC in until it lodges firmly in the AS MLC.
CAUTION: Slide the AS MSC straight into the slot to avoid damaging the components on the bottom of the AS MSC.
3.
Use one of the following methods to bring the AS MSC online:
• Press the AS MSC offline/online button until the LED light turns green.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
Copyright © 2017, Juniper Networks, Inc.
319
MX960 3D Universal Edge Router Hardware Guide
The normal functioning status LED confirms that the AS MSC is online. You can also verify correct AS MSC functioning by issuing the show chassis fpc pic-status .
Figure 122: Installing an AS MSC
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing an MX960 AS MLC on page 313
•
MX960 Application Services Modular Storage Card Description on page 72
Replacing an MX960 AS MXC
1.
Removing an MX960 AS MXC on page 321
2.
Installing an MX960 AS MXC on page 322
320 Copyright © 2017, Juniper Networks, Inc.
Chapter 22: Replacing Chassis Components
Removing an MX960 AS MXC
AS MXCs are hot-insertable and hot-removable. When you remove an AS MXC, the router continues to function.
The AS MXCs are located in the AS MLCs installed in the front of the router. An AS MXC weighs less than 2 lb (0.9 kg).
To remove an AS MXC (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the AS
MXC.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Use one of the following methods to take the AS MXC offline:
• Press its online/offline button. Use a narrow-ended tool that fits inside the opening that leads to the button. Press and hold the button until the AS MXC LED goes out
(about 5 seconds).
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see the CLI Explorer .
5.
Slide the AS MXC out of the AS MLC card carrier by pulling the handles, and place it in the electrostatic bag or on the antistatic mat.
6.
If you are not reinstalling an AS MXC into the emptied AS MXC slot within a short time, install a blank AS MXC panel over the slot to maintain proper airflow in the AS MLC card cage.
Copyright © 2017, Juniper Networks, Inc.
321
MX960 3D Universal Edge Router Hardware Guide
Figure 123: Removing an AS MXC
Installing an MX960 AS MXC
To install an AS MXC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Align the notches in the connector at the rear of the AS MXC with the notches in the
AS MXC slot (slot 1—the bottom slot in the AS MLC), and then slide the AS MXC in until it lodges firmly in the AS MLC.
CAUTION: Slide the AS MXC straight into the slot to avoid damaging the components on the bottom of the AS MXC.
3.
Use one of the following methods to bring the AS MXC online:
• Press the AS MXC offline/online button until the LED light turns green.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
322 Copyright © 2017, Juniper Networks, Inc.
Chapter 22: Replacing Chassis Components
For more information about the command, see the CLI Explorer .
The normal functioning status LED confirms that the AS MXC is online. You can also verify correct AS MXC functioning by issuing the show chassis fpc pic-status command.
Figure 124: Installing an AS MXC
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing an MX960 AS MLC on page 313
•
MX960 Application Services Modular Processing Card Description on page 73
Copyright © 2017, Juniper Networks, Inc.
323
MX960 3D Universal Edge Router Hardware Guide
324 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 23
Replacing Cooling System Component
•
Replacing the MX960 Air Filter on page 325
•
Replacing an MX960 Fan Tray on page 327
Replacing the MX960 Air Filter
1.
Removing the Normal-Capacity MX960 Air Filter on page 325
2.
Installing the MX960 Air Filter on page 326
Removing the Normal-Capacity MX960 Air Filter
CAUTION: Do not run the router for more than a few minutes without the air filter in place.
CAUTION: Always keep the air filter in place while the router is operating, except during replacement. Because the fans are very powerful, they could pull small bits of wire or other materials into the router through the unfiltered air intake. This could damage the router components.
To remove the normal-capacity air filter tray, use the following procedure.
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Unwrap any cables on the standard cable manager and remove the cables from the tray. Arrange the cables so that they do not block the front of the cable manager and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
NOTE: Removing the cables from the extended cable manager is not necessary to access the air filter.
Copyright © 2017, Juniper Networks, Inc.
325
MX960 3D Universal Edge Router Hardware Guide
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Do not run the router for more than two minutes without the air filter in place.
3.
Simultaneously pull the two releases labeled PULL on the standard cable manager.
Lift it up and outward to lock it in place to access the air filter.
4.
Pull the filter tray release on both sides of the filter tray.
5.
Slide the air filter tray out of the chassis as shown in
Figure 125: Removing the Normal-Capacity Air Filter Tray from the Chassis
Installing the MX960 Air Filter
To install the air filter (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Ensure that the air filter is right side up.
3.
Place the air filter into the air filter tray.
326 Copyright © 2017, Juniper Networks, Inc.
Chapter 23: Replacing Cooling System Component
4.
Insert the air filter tray into the chassis by sliding it straight into the chassis until it stops.
5.
Lower the cable manager back into position.
6.
Rearrange the cables in the cable manager.
Figure 126: Installing the Air Filter
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Maintaining the MX960 Air Filter on page 446
Replacing an MX960 Fan Tray
1.
Removing an MX960 Fan Tray on page 327
2.
Installing an MX960 Fan Tray on page 329
Removing an MX960 Fan Tray
NOTE: To prevent overheating, install the replacement fan tray immediately after removing the existing fan tray.
To remove the upper or lower fan tray (see
and
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Reposition the standard cable manager before removing the lower front fan tray:
NOTE: This step is not required for the extended cable manager.
a.
Unwrap any cables on the standard cable manager and remove the cables from the tray. Arrange the cables so that they do not block the front of the cable manager and tray, and secure them with temporary fasteners so that they are not supporting their own weight as they hang from the connector.
Copyright © 2017, Juniper Networks, Inc.
327
MX960 3D Universal Edge Router Hardware Guide b.
Simultaneously pull the two releases labelled PULL on the cable manager. Lift it up and outward to lock it in place.
3.
Loosen the captive screw on each side of the fan tray faceplate.
4.
Grasp both sides of the fan tray, and pull it out approximately 1 to 3 inches.
WARNING: To avoid injury, keep tools and your fingers away from the fans as you slide the fan tray out of the chassis. The fans might still be spinning.
5.
Pause for approximately 15 seconds to allow the fans to stop spinning.
6.
When the fans stop spinning, press on the two latches located on the inside of the fan tray.
7.
Place one hand under the fan tray to support it, and pull the fan tray completely out of the chassis.
Figure 127: Removing an Upper Fan Tray
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
328 Copyright © 2017, Juniper Networks, Inc.
Chapter 23: Replacing Cooling System Component
Figure 128: Removing a Lower Fan Tray
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
YELL
M
OK FAIL
7
ONLINE
ACO/LT
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK
FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Installing an MX960 Fan Tray
To install a fan tray (see
and
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Grasp the fan tray on each side, and insert it straight into the chassis. Note the correct orientation by the "this side up" label on the top surface of the fan tray.
3.
Tighten the captive screws on each side of the fan tray faceplate to secure it in the chassis.
4.
Lower the cable manager back into position, if necessary.
Copyright © 2017, Juniper Networks, Inc.
329
MX960 3D Universal Edge Router Hardware Guide
Figure 129: Installing an Upper Fan Tray
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
330 Copyright © 2017, Juniper Networks, Inc.
Chapter 23: Replacing Cooling System Component
Figure 130: Installing a Lower Fan Tray
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
YELL
M
OK FAIL
7
ONLINE
ACO/LT
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK
FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Maintaining the MX960 Fan Trays on page 446
Copyright © 2017, Juniper Networks, Inc.
331
MX960 3D Universal Edge Router Hardware Guide
332 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 24
Replacing Host Subsystem Components
•
Replacing an MX960 Routing Engine on page 333
•
Replacing an SSD Drive on an RE-S-1800 on page 336
•
Replacing an SSD Drive on an RE-S-X6-64G on page 338
•
Replacing Connections to MX960 Routing Engine Interface Ports on page 343
•
Upgrading to the RE-S-X6-64G Routing Engine in a Redundant Host
•
Upgrading to the RE-S-X6-64G Routing Engine in a Nonredundant Host
Replacing an MX960 Routing Engine
1.
Removing an MX960 Routing Engine on page 333
2.
Installing an MX960 Routing Engine on page 335
Removing an MX960 Routing Engine
Before you remove a Routing Engine, remove the cables that connect to it.
CAUTION: Before you replace a Routing Engine, you must take the host subsystem offline. If there is only one host subsystem, taking the host subsystem offline shuts down the router.
CAUTION: If the Routing Engine to be replaced is currently functioning as the master Routing engine, switch it to be the backup before removing it.
To remove a Routing Engine from an SCB (see
):
1.
Take the Routing Engine offline gracefully.
2.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
Copyright © 2017, Juniper Networks, Inc.
333
MX960 3D Universal Edge Router Hardware Guide
3.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
4.
Verify that the Routing Engine LEDs are off.
5.
Loosen the captive screws on the top and bottom of the Routing Engine.
6.
Flip the ejector handles outward to unseat the Routing Engine.
7.
Grasp the Routing Engine by the ejector handles, and slide it about halfway out of the chassis.
8.
Place one hand underneath the Routing Engine to support it, and slide it completely out of the chassis.
9.
Place the Routing Engine on the antistatic mat.
NOTE: To maintain proper airflow through the chassis, do not leave an
SCB installed in the chassis without a Routing Engine for extended periods of time. If a Routing Engine is removed, a replacement Routing Engine should be installed as soon as possible.
334 Copyright © 2017, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
Figure 131: Removing a Routing Engine
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Installing an MX960 Routing Engine
To install a Routing Engine into an SCB (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Ensure that the ejector handles are not in the locked position. If necessary, flip the ejector handles outward.
3.
Place one hand underneath the Routing Engine to support it.
4.
Carefully align the sides of the Routing Engine with the guides inside the opening on the SCB.
5.
Slide the Routing Engine into the SCB until you feel resistance, and then press the
Routing Engine's faceplate until it engages the connectors.
6.
Press both of the ejector handles inward to seat the Routing Engine.
Copyright © 2017, Juniper Networks, Inc.
335
MX960 3D Universal Edge Router Hardware Guide
7.
Tighten the captive screws on the left and right of the Routing Engine.
8.
Connect the management device cables to the Routing Engine.
The Routing Engine might require several minutes to boot.
After the Routing Engine boots, verify that it is installed correctly by checking the FAIL ,
RE0 , and RE1 LEDs on the craft interface. If the router is operational and the Routing
Engine is functioning properly, the green ONLINE LED lights steadily. If the red FAIL LED lights steadily instead, remove and install the Routing Engine again. If the red FAIL LED still lights steadily, the Routing Engine is not functioning properly. Contact your customer support representative.
To check the status of the Routing Engine, use the CLI command: user@host> show chassis routing-engine
Routing Engine status: Slot 0: Current state Master ...
For more information about using the CLI, see the Junos OS documentation.
Figure 132: Installing a Routing Engine
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing Connections to MX960 Routing Engine Interface Ports on page 343
•
MX960 Routing Engine Description on page 29
•
Routing Engine Interface Cable and Wire Specifications for MX Series Routers on page 142
• Synchronizing Routing Engines
Replacing an SSD Drive on an RE-S-1800
Each RE-S-1800 Routing Engine supports two solid-state drives (SSD) specified by
Juniper Networks. The RE-S-1800 ships with one SSD installed in the slot labeled SATA
SSD 1 . The spare SSD is Juniper part number RE-SSD-32G-UPG.
shows the arrangement of storage drive slots on a RE-S-1800 Routing Engine.
336 Copyright © 2017, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
Figure 133: RE-S-1800 Storage Drive Slots
Auxiliary port
Ethernet port
Online/Offline button
SSD slot 1
SSD slot 2
Extractor clip
Console port
USB port
Status LEDs Extractor clip
The following drive has been verified to work in the RE-S-1800 Routing Engine:
• SSD SLC 32 GB
To replace a storage drive:
1.
Disable and deactivate the storage drive.
2.
Remove the storage drive.
a.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to an ESD point on the appliance.
For more information about ESD, see Preventing Electrostatic Discharge Damage in the hardware guide for your router.
b.
Unfasten the thumbscrew that secures the access door in front of the storage drive slots, and open the door.
c.
Slide the lock on the ejector to the unlocked position.
d.
Carefully slide the drive out of the slot.
3.
Reinstall a storage drive.
a.
Carefully align the sides of the drive with the guides in the slot.
b.
Slide the drive into the slot until you feel resistance, carefully ensuring that it is correctly aligned.
c.
Close the access door and tighten the thumbscrew to secure the door.
Related
Documentation
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
Copyright © 2017, Juniper Networks, Inc.
337
MX960 3D Universal Edge Router Hardware Guide
Replacing an SSD Drive on an RE-S-X6-64G
Each RE-S-X6-64G Routing Engine supports two solid-state drives (SSD) specified by
Juniper Networks. The RE-S-X6-64G ships with two SSDs installed in the slot labeled
DISK1 and DISK2 .
shows the arrangement of storage drive slots on a RE-S-X6-64G Routing Engine.
Replacing an SSD drive in a RE-S-X6-64G Routing Engine consists of the following two stages:
1.
Replacing the SSD Drive in the Routing Engine.
2.
Copying vmhost and Junos OS to the replaced SSD.
Figure 134: RE-S-X6-64G Storage Drive Slots
338 Copyright © 2017, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
The following drive has been verified to work in the RE-S-X6-64G Routing Engine:
• 64GB slim SATA SSD
Replacing the SSDs:
1.
To replace an SSD in the slot labeled Disk2 : a. Make sure that there is no VMHost %d Boot from alternate disk alarm in the output: user@host> show chassis alarm
To replace an SSD in the slot labeled Disk1 : a. Make sure that the router is booted up and running from an image from disk1.
Back up the currently running vmhost and Junos OS on disk1 to ensure that both disk1 and disk2 have the same version of vmhost and Junos OS: user@host> request vmhost snapshot [partition]
NOTE: Partitioning the target media is optional.
b. Reboot the router from disk2: user@host> request vmhost reboot disk2 c. Check for the presence of the VMHost %d Boot from alternate disk alarm in the output: user@host> show chassis alarm
2.
Offline the Routing Engine by pressing the ONLINE/OFFLINE button.
Copyright © 2017, Juniper Networks, Inc.
339
MX960 3D Universal Edge Router Hardware Guide
3.
Remove the SSD.
a.
Attach an ESD grounding strap to your bare wrist, and connect the strap to an ESD point on the appliance.
For more information about ESD, see Preventing Electrostatic Discharge Damage in the hardware guide for your router.
b.
Unfasten the thumbscrew that secures the access door in front of the storage drive slots, and open the door.
c.
Slide the lock on the ejector to the unlocked position.
d.
Carefully slide the drive out of the slot.
Figure 135: Removing an SSD in the Routing Engine RE-S-X6-64G
340
4.
Reinstall an SSD: a.
Carefully align the sides of the drive with the guides in the slot.
b.
Slide the drive into the slot until you feel resistance, carefully ensuring that it is correctly aligned.
c.
Close the access door and tighten the thumbscrew to secure the door.
Copyright © 2017, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
1.
Copy Junos OS to the newly replaced SSD:
If both the SSDs are replaced together: a. Install using an USB disk:
1.
Insert the USB disk in the USB slot on the Routing Engine.
2.
After the Routing Engine boots from the USB, press y when you are prompted to confirm Install vmhost and Junos software on Primary and Secondary disk
[y/N?
on the console.
3.
After the installation is completed, press y when prompted to confirm Reboot now? [y/N]?
to reboot from the SSD disk.
NOTE: To prepare a bootable USB disk, see b. Install vmhost using the PXEBoot method:
1.
Set up the PXEBoot server < Provide the link to the PXEBoot tech pub document that Hema is writing>
2.
Bring the Routing Engine online by pressing the ONLINE/OFFLINE button
3.
During the boot, when you see the message Press Esc for boot options press Esc key to enter into the BIOS menu boot options.
After the Esc key is pressed, Esc is pressed. Go to boot options.
is displayed on the screen.
4.
Using Up or Down arrow keys, navigate to Boot Manager and press the Enter key.
5.
Using Up or Down arrow keys, navigate through the EFI boot devices listed and select EFI Network 0 for IPv4 to boot from the PXEboot server and press the
Enter key.
6.
Booting `net boot console is displayed and PXEBoot continues.
NOTE: The booting process may take several minutes.
7.
After the Routing Engine boots, press y when you are prompted to confirm Install vmhost and Junos software on Primary and Secondary disk [y/N?
on the console.
8.
After the installation is completed, press y when prompted to confirm Reboot now? [y/N]?
to reboot from the SSD disk.
If only disk2 is replaced: a. Bring the Routing Engine online by pressing the ONLINE/OFFLINE button.
b. The router boots from disk1. To be able to boot from disk2: user@host> request vmhost snapshot partition
Copyright © 2017, Juniper Networks, Inc.
341
MX960 3D Universal Edge Router Hardware Guide
If only disk1 is replaced: a. Bring the Routing Engine online by pressing the ONLINE/OFFLINE button.
b. The router boots from disk2 . To be able to boot from disk1: user@host> request vmhost snapshot partition
Figure 136: Installing an SSD in the Routing Engine RE-S-X6-64G
342
1— Carrier 2— SSD card
Copying vmhost and Junos OS from an USB disk when both the SSDs are replaced together :
NOTE: To prepare a bootable USB disk, see Creating an Emergency Boot Device for RE-MX-X6, RE-MX-X8 and RE-PTX-X8 Routing Engines .
1.
Insert the USB disk in the USB slot on the Routing Engine.
2.
After the Routing Engine boots from the USB, press y when you are prompted to confirm Install vmhost and Junos software on Primary and Secondary disk [y/N]?
on the console.
3.
After the installation is completed, press y when prompted to confirm Reboot now?
[y/N]?
to reboot from the SSD disk.
Copying vmhost and Junos OS to the SSDs from the PXEBoot server :
1.
Set up the PXEBoot server. See Copying VM Host Installation Package to the PXE Boot
Server .
2.
Bring the Routing Engine online by pressing the ONLINE/OFFLINE button.
3.
During the boot, when you see the message Press Esc for boot options press Esc key to enter into the BIOS menu boot options.
Copyright © 2017, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
After the Esc key is pressed, Esc is pressed. Go to boot options.
is displayed on the screen.
4.
Using Up or Down arrow keys, navigate to Boot Manager and press the Enter key.
5.
Using Up or Down arrow keys, navigate through the EFI boot devices listed and select
EFI Network 0 for IPv4 to boot from the PXEboot server and press the Enter key.
6.
Booting `net boot console is displayed and PXEBoot continues.
NOTE: The booting process may take several minutes.
7.
After the Routing Engine boots, press y when you are prompted to confirm Install vmhost and Junos software on Primary and Secondary disk [y/N]?
on the console.
8.
After the installation is completed, press y when prompted to confirm Reboot now?
[y/N]?
to reboot from the SSD disk.
Copying vmhost and Junos OS when only one disk is replaced : a. Bring the Routing Engine online by pressing the ONLINE/OFFLINE button.
b. The router boots from disk1 if disk2 is replaced. To be able to boot from disk2: user@host> request vmhost snapshot partition
The router boots from disk2 if disk1 is replaced. To be able to boot from disk1: user@host> request vmhost snapshot recovery partition
Related
Documentation
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
• Upgrading the SSD Firmware on RE-S-X6-64G and RE-MX2K-X8-64G Routing Engines
Replacing Connections to MX960 Routing Engine Interface Ports
•
Replacing the Management Ethernet Cable on an MX Series Router on page 344
•
Replacing the Console or Auxiliary Cable on an MX960 Router on page 344
Copyright © 2017, Juniper Networks, Inc.
343
MX960 3D Universal Edge Router Hardware Guide
Replacing the Management Ethernet Cable on an MX Series Router
One Ethernet cable with RJ-45 connectors is provided with the router. To replace the cable connected to the ETHERNET port:
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Press the tab on the connector, and pull the connector straight out of the port.
shows the connector.
3.
Disconnect the cable from the network device.
4.
Plug one end of the replacement cable into the ETHERNET port.
shows the port.
5.
Plug the other end of the cable into the network device.
Figure 137: Cable Connector
Figure 138: Ethernet Port
Replacing the Console or Auxiliary Cable on an MX960 Router
To use a system console to configure and manage the Routing Engine, connect it to the
CONSOLE port on the Routing Engine. To use a laptop, modem, or other auxiliary device, connect it to the AUX port on the Routing Engine. Both ports accept a cable with an RJ-45 connector. One RJ-45/DB-9 cable is provided with the router. If you want to connect a device to both ports, you must supply another cable.
To replace a cable connected to a management console or auxiliary device:
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Press the tab on the connector, and pull the connector straight out of the port.
344 Copyright © 2017, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
3.
Disconnect the cable from the console or auxiliary device.
4.
Plug the RJ-45 end of the replacement serial cable into the CONSOLE or AUX port.
shows the external device ports on the Routing Engine.
5.
Plug the female DB-9 end into the console or auxiliary device's serial port.
Figure 139: Auxiliary and Console Ports
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Routing Engine Interface Cable and Wire Specifications for MX Series Routers on page 142
•
Replacing an MX960 Routing Engine on page 333
Upgrading to the RE-S-X6-64G Routing Engine in a Redundant Host Subsystem
A redundant host subsystem consists of a master Routing Engine (RE0) and a backup
Routing Engine (RE1). To upgrade the host subsystem to use the RE-S-X6-64G Routing
Engine, you must first uninstall the backup Routing Engine and install the RE-S-X6-64G
Routing Engine, which then becomes the backup Routing Engine. You then switch over this backup Routing Engine to make it the master Routing Engine. Replace the other
Routing Engine and configure it as the backup Routing Engine.
Ensure that the Switch Control Board in the chassis is SCBE2 because the RE-S-X6-64G
Routing Engine is not compatible with the Switch Control Boards SCB or SCBE. To upgrade the Switch Control Board to SCBE2, see Replacing an MX240 SCB or Replacing an MX480
SCB or
“Replacing an MX960 SCB” on page 409 , depending on the chassis on which the
Routing Engine is being upgraded.
NOTE: Save the router configuration before proceeding with the Routing
Engine upgrade.
Copyright © 2017, Juniper Networks, Inc.
345
MX960 3D Universal Edge Router Hardware Guide
NOTE: Nonstop active routing (NSR) and graceful Routing Engine switchover
(GRES) are not supported during the upgrade and they must be temporarily disabled. Disable NSR by removing the nonstop-routing statement from the
[ edit routing-options ] hierarchy level and by removing the graceful-switchover statement from the [ edit chassis redundancy ] hierarchy level .
1.
Removing the Routing Engine on page 346
2.
Installing the Routing Engine RE-S-X6-64G on page 348
3.
Verifying and Configuring the Upgraded Routing Engine as the Master on page 351
4.
Verifying and Configuring the Upgraded Routing Engine as the Backup on page 351
Removing the Routing Engine
To remove the backup Routing Engine from the chassis (see
,
):
1.
On the external management device connected to the Routing Engine, shut down the host subsystem by using the request system power-off command.
2.
Wait until a message appears on the console confirming that the operating system has halted.
3.
Remove the cables connected to the Routing Engine.
4.
Place an electrostatic bag or antistatic mat on a flat, stable surface. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
5.
Verify that the Routing Engine LEDs are off. Loosen the captive screws on the top and bottom of the Routing Engine.
6.
Grasp the Routing Engine by the ejector handles, and slide it about halfway out of the chassis.
7.
Place one hand underneath the Routing Engine to support it, and slide it completely out of the chassis. Place the Routing Engine on the antistatic mat.
NOTE: To maintain proper airflow through the chassis, do not leave an SCB installed in the chassis without a Routing Engine for extended periods of time.
If a Routing Engine is removed, a replacement Routing Engine should be installed as soon as possible.
346 Copyright © 2017, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
Figure 140: Removing a Routing Engine from an MX240 Router
Figure 141: Removing a Routing Engine from an MX480 Router
Copyright © 2017, Juniper Networks, Inc.
347
MX960 3D Universal Edge Router Hardware Guide
Figure 142: Removing a Routing Engine from an MX960 Router
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Installing the Routing Engine RE-S-X6-64G
To install the Routing Engine RE-S-X6-64G:
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Ensure that the ejector handles are not in the locked position. If necessary, flip the ejector handles outward.
3.
Place one hand underneath the Routing Engine to support it and carefully align the sides of the Routing Engine with the guides inside the opening on the Switch Control
Board SCBE2.
NOTE: The Routing Engine RE-S-X6-64G is supported only on the SCBE2.
RE-S-X6-64G is not compatible with the SCB or the SCBE.
4.
Slide the Routing Engine into the SCBE2 until you feel resistance, and then press the
Routing Engine's faceplate until it engages the connectors.
348 Copyright © 2017, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
5.
Press both of the ejector handles inward to seat the Routing Engine. Tighten the captive screws on the top and bottom of the Routing Engine.
6.
Connect the management device cables to the Routing Engine. After the Routing
Engine is installed, the ONLINE LED starts blinking green slowly.
7.
Replace the former master Routing Engine, RE0, with the Routing Engine RE-S-X6-64G.
NOTE: The Routing Engine RE-S-X6-64G is supported only on the SCBE2.
RE-S-X6-64G is not compatible with the SCB or the SCBE.
The Routing Engine might require several minutes to boot. After the Routing Engine boots, verify that it is installed correctly by checking the FAIL , RE0 , and RE1 LEDs on the craft interface. If the router is operational and the Routing Engine is functioning properly, the green ONLINE LED on the Routing Engine lights steadily. If the red FAIL LED on the Routing
Engine lights steadily instead, remove and install the Routing Engine again. If the red FAIL
LED still lights steadily, the Routing Engine is not functioning properly. Contact your customer support representative.
Figure 143: Installing a Routing Engine in an MX240 Router
Copyright © 2017, Juniper Networks, Inc.
349
MX960 3D Universal Edge Router Hardware Guide
Figure 144: Installing a Routing Engine in an MX480 Router
Figure 145: Installing a Routing Engine in an MX960 Router
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK
FAIL OK
FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK
FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK
FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO NC
C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
350 Copyright © 2017, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
Verifying and Configuring the Upgraded Routing Engine as the Master
After replacing the backup Routing Engine with the RE-S-X6-64G Routing Engine, perform the following steps:
1.
Verify that the SCBE2 and RE-S-X6-64G Routing Engine are online by issuing the show chassis hardware command.
2.
After you install the RE-S-X6-64G Routing Engine into the SCBE2, the Routing Engine gets automatically powered on and comes up in amnesiac mode as it is loaded with factory defaults. After the Routing Engine comes up in amnesiac mode, load the base configuration and commit.
3.
Configure the backup Routing Engine by using the commit synchronize command to copy the configuration to the backup Routing Engine.
4.
Use the request chassis routing-engine master switch command to make the Routing
Engine RE-S-X6-64G (RE1) the master Routing Engine. All FPCs reboot after this step.
Verifying and Configuring the Upgraded Routing Engine as the Backup
1.
Use the request chassis routing-engine master switch command to make newly installed
RE-S-X6-64G (RE0) the backup Routing Engine.
2.
Use the commit synchronize command to copy the active configuration from the master Routing Engine to the backup Routing Engine.
Related
Documentation
•
RE-S-X6-64G Routing Engine Description on page 34
•
Upgrading to the RE-S-X6-64G Routing Engine in a Nonredundant Host Subsystem on page 351
Upgrading to the RE-S-X6-64G Routing Engine in a Nonredundant Host Subsystem
In a nonredundant host subsystem, only one Routing Engine and one Switch Control
Board are present in the chassis. When you are upgrading the Routing Engine, taking the host subsystem offline shuts down the router. To upgrade the host subsystem with the
RE-S-X6-64G Routing Engine, you must uninstall the existing Routing Engine and install the RE-S-X6-64G Routing Engine. Ensure that the Switch Control Board in the chassis is SCBE2 because the RE-S-X6-64G Routing Engine is not compatible with the Switch
Control Boards SCB or SCBE. To upgrade the Switch Control Board to SCBE2, see
Replacing an MX240 SCB or Replacing an MX480 SCB or
“Replacing an MX960 SCB” on page 409
, depending on the chassis on which the Routing Engine is being upgraded.
Copyright © 2017, Juniper Networks, Inc.
351
MX960 3D Universal Edge Router Hardware Guide
NOTE: Save the router configuration before proceeding with the Routing
Engine upgrade.
1.
Removing the Routing Engine on page 352
2.
Installing the Routing Engine RE-S-X6-64G on page 353
Removing the Routing Engine
To remove the Routing Engine from the chassis:
1.
On the external management device connected to the Routing Engine, shut down the host subsystem by using the request system power-off command.
2.
Wait until a message appears on the console confirming that the operating system has halted.
3.
Remove the cables connected to the Routing Engine.
4.
Place an electrostatic bag or antistatic mat on a flat, stable surface. Attach an ESD grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
5.
Verify that the Routing Engine LEDs are off. Loosen the captive screws on the top and bottom of the Routing Engine.
6.
Grasp the Routing Engine by the ejector handles, and slide it about halfway out of the chassis.
7.
Place one hand underneath the Routing Engine to support it, and slide it completely out of the chassis. Place the Routing Engine on the antistatic mat.
NOTE: To maintain proper airflow through the chassis, do not leave an SCB installed in the chassis without a Routing Engine for extended periods of time.
If a Routing Engine is removed, a replacement Routing Engine should be installed as soon as possible.
352 Copyright © 2017, Juniper Networks, Inc.
Chapter 24: Replacing Host Subsystem Components
Installing the Routing Engine RE-S-X6-64G
To install the new Routing Engine (RE-S-X6-64G):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Ensure that the ejector handles are not in the locked position. If necessary, flip the ejector handles outward.
3.
Place one hand underneath the Routing Engine to support it and carefully align the sides of the Routing Engine with the guides inside the opening on the SCBE2.
NOTE: The Routing Engine RE-S-X6-64G is supported only on the SCBE2.
RE-S-X6-64G is not compatible with the SCB or the SCBE.
4.
Slide the Routing Engine into the SCBE2 until you feel resistance, and then press the
Routing Engine's faceplate until it engages the connectors.
5.
Press both of the ejector handles inward to seat the Routing Engine. Tighten the captive screws on the top and bottom of the Routing Engine.
6.
Connect the management device cables to the Routing Engine. After the Routing
Engine is installed, the ONLINE LED starts blinking green slowly.
7.
Verify that the SCBE2 and RE-S-X6-64G Routing Engine are online by issuing the show chassis hardware command.
8.
After you install the RE-S-X6-64G Routing Engine into the SCBE2, the Routing Engine gets automatically powered on and comes up in amnesiac mode as it is loaded with factory defaults. After the Routing Engine comes up in amnesiac mode, load the base configuration and commit.
The Routing Engine might require several minutes to boot. After the Routing Engine boots, verify that it is installed correctly by checking the FAIL , RE0 , and RE1 LEDs on the craft interface. If the router is operational and the Routing Engine is functioning properly, the green ONLINE LED on the Routing Engine lights steadily. If the red FAIL LED lights steadily instead, remove the Routing Engine and reinstall it. If the red FAIL LED on the Routing
Engine still lights steadily, the Routing Engine is not functioning properly. Contact your customer support representative.
Related
Documentation
•
RE-S-X6-64G Routing Engine Description on page 34
•
Upgrading to the RE-S-X6-64G Routing Engine in a Redundant Host Subsystem on page 345
Copyright © 2017, Juniper Networks, Inc.
353
MX960 3D Universal Edge Router Hardware Guide
354 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 25
Replacing Line Card Components
•
Replacing an MX960 DPC on page 355
•
Replacing an MX960 FPC on page 361
•
Replacing an MX960 MIC on page 367
•
Replacing an MX960 MPC on page 376
•
Replacing an MX960 PIC on page 382
•
Replacing a Cable on an MX960 DPC, MPC, MIC, or PIC on page 386
Replacing an MX960 DPC
1.
Removing an MX960 DPC on page 355
2.
Installing an MX960 DPC on page 357
Removing an MX960 DPC
A DPC weighs up to 13.1 lb (5.9 kg). Be prepared to accept its full weight.
To remove a DPC (see
):
1.
Have ready a replacement DPC or DPC blank panel and an antistatic mat for the DPC.
Also have ready rubber safety caps for each DPC you are removing that uses an optical interface.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Label the cables connected to each port on the DPC so that you can later reconnect the cables to the correct ports.
4.
Use one of the following methods to take the DPC offline:
• Press and hold the corresponding DPC online button on the craft interface. The green OK LED next to the button begins to blink. Hold the button down until the LED goes off.
• Issue the following CLI command:
Copyright © 2017, Juniper Networks, Inc.
355
MX960 3D Universal Edge Router Hardware Guide user@host> request chassis fpc slot slot-number offline
For more information about the command, see the CLI Explorer .
5.
Disconnect the cables from the DPC.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
6.
Immediately cover each optical transceiver and the end of each fiber-optic cable with a rubber safety cap.
7.
Arrange the disconnected cables in the standard or extended cable manager to prevent the cables from developing stress points.
8.
Simultaneously turn both of the ejector handles counterclockwise to unseat the DPC.
9.
Grasp the handles, and slide the DPC straight out of the card cage halfway.
10.
Place one hand around the front of the DPC and the other hand under it to support it.
Slide the DPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the DPC is concentrated in the back end. Be prepared to accept the full weight—up to 13.1 lb (5.9 kg)—as you slide the
DPC out of the chassis.
When the DPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
356 Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
Do not stack DPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
11.
If you are not reinstalling a DPC into the emptied DPC slot within a short time, install a blank DPC panel over the slot to maintain proper airflow in the DPC card cage.
CAUTION: After removing a DPC from the chassis, wait at least 30 seconds before reinserting it, removing a DPC from a different slot, or inserting a
DPC into a different slot.
Figure 146: Removing a DPC
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK
FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK
FAIL
5
ONLINE
RE0
OK
FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
OK FAIL
NC
C NO NC
OK FAIL
C
NO
OK
FAIL
8
ONLINE
9
ONLINE
10
ONLINE
OK FAIL
11
ONLINE
OK/FAIL
0/0 0/5
2/0 2/5
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1/0 1/5
3/0 3/5
Installing an MX960 DPC
A DPC weighs up to 14.5 lb (6.6 kg). Be prepared to accept its full weight.
Copyright © 2017, Juniper Networks, Inc.
357
MX960 3D Universal Edge Router Hardware Guide
To install a DPC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place the DPC on an antistatic mat, or remove it from its electrostatic bag.
3.
Identify the slot on the router where it will be installed.
4.
Verify that each fiber-optic transceiver is covered with a rubber safety cap. If it does not, cover the transceiver with a safety cap.
5.
Orient the DPC so that the faceplate faces youvertically.
6.
Lift the DPC into place, and carefully align the sides of the DPC with the guides inside the card cage.
7.
Slide the DPC all the way into the card cage until you feel resistance.
8.
Grasp both ejector handles, and rotate them clockwise simultaneously until the DPC is fully seated.
9.
Remove the rubber safety cap from each fiber-optic transceiver and cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
10.
Insert the cables into the cable connector ports on each DPC (see
).
11.
Arrange the cable in the standard or extended cable manager to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
358 Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
12.
Use one of the following methods to bring the DPC online:
• Press and hold the corresponding DPC online button on the craft interface until the green OK LED next to the button lights steadily, in about 5 seconds.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer .
CAUTION: After the OK LED turns green, wait at least 30 seconds before removing the DPC again, removing a DPC from a different slot, or inserting a DPC in a different slot.
You can also verify that the DPC is functioning correctly by issuing the show chassis fpc and show chassis fpc pic-status commands.
Copyright © 2017, Juniper Networks, Inc.
359
MX960 3D Universal Edge Router Hardware Guide
Figure 147: Installing a DPC
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
YELL M
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
0/0 0/5
OK/FAIL
2/0 2/5
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1/0 1/5
3/0 3/5
360 Copyright © 2017, Juniper Networks, Inc.
Figure 148: Attaching a Cable to a DPC
Chapter 25: Replacing Line Card Components
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Holding an MX960 DPC on page 452
•
Storing an MX960 DPC on page 454
• MX960 DPC Terminology
•
Maintaining MX960 DPCs on page 450
•
Troubleshooting the MX960 DPCs on page 490
Replacing an MX960 FPC
•
Removing an MX960 FPC on page 361
•
Installing an MX960 FPC on page 364
Removing an MX960 FPC
When you remove an FPC, the router continues to function, although the PIC interfaces installed on the FPC being removed no longer function.
An FPC takes up two DPC slots on the MX960 router. Up to six FPCs can be installed vertically in the front of the MX960 router. The FPCs are hot-insertable and hot-removable.
Copyright © 2017, Juniper Networks, Inc.
361
MX960 3D Universal Edge Router Hardware Guide
An empty FPC3 weighs 14 lb (6.5 kg). A fully configured FPC can weigh up to 18 lb (8.2 kg).
Be prepared to accept its full weight.
To remove an FPC (see
1.
Have ready a replacement FPC or FPC blank panel and an antistatic mat for the FPC.
Also have ready rubber safety caps for each PIC using an optical interface on the FPC that you are removing.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Label the cables connected to each PIC on the FPC so that you can later reconnect the cables to the correct PICs.
4.
Use one of the following methods to take the FPC offline:
• Press and hold the FPC online/offline button. The green OK LED next to the button begins to blink. Hold the button down until the LED goes out. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number offline
For more information about the command, see the CLI Explorer .
NOTE: The slot number corresponds to the lowest numbered slot for which the FPC is installed.
5.
Disconnect the cables from the PICs installed in the FPC.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
362 Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
6.
If a PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap. Arrange the disconnected cables in the cable manager to prevent the cables from developing stress points.
7.
Simultaneously turn both the ejector handles counterclockwise to unseat the FPC.
8.
Grasp the handles, and slide the FPC straight out of the card cage halfway.
9.
Place one hand around the front of the FPC (the PIC housing) and the other hand under it to support it. Slide the FPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the FPC is concentrated in the back end. Be prepared to accept the full weight—up to 18 lb (8.2 kg)—as you slide the
FPC out of the chassis.
When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
Do not stack FPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
10.
If necessary, remove each installed PIC from the FPC.
11.
After you remove each PIC, immediately place it on an antistatic mat or in an electrostatic bag.
12.
If you are not reinstalling an FPC into the emptied DPC slots within a short time, install a blank DPC panel over each slot to maintain proper airflow in the card cage.
CAUTION: After removing an FPC from the chassis, wait at least 30 seconds before reinserting it or inserting an FPC into a different slot.
Copyright © 2017, Juniper Networks, Inc.
363
MX960 3D Universal Edge Router Hardware Guide
Figure 149: Removing an FPC
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
REDALAR M
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Installing an MX960 FPC
An FPC takes up two DPC slots on the MX960 router. Up to six FPCs can be installed vertically in the front of the router. The FPCs are hot-insertable and hot-removable. An empty FPC3 weighs 14 lb (6.5 kg). A fully configured FPC can weigh up to 18 lb (8.2 kg).
Be prepared to accept its full weight.
To install an FPC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place the FPC on an antistatic mat.
3.
Take each PIC to be installed in the replacement FPC out of its electrostatic bag, and identify the slot on the FPC where it will be connected.
4.
Verify that each fiber-optic PIC has a rubber safety cap covering the PIC transceiver.
If it does not, cover the transceiver with a safety cap.
5.
Install each PIC into the appropriate slot on the FPC.
364 Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
6.
Locate the two slots in the card cage in which you plan to install the FPC.
7.
Orient the FPC so that the faceplate faces you.
8.
Lift the FPC into place, and carefully align the sides of the FPC with the guides inside the card cage.
CAUTION: When the FPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
9.
Slide the FPC all the way into the card cage until you feel resistance.
10.
Grasp both ejector handles, and rotate them clockwise simultaneously until the FPC is fully seated.
11.
If any of the PICs on the FPC connect to fiber-optic cable, remove the rubber safety cap from each transceiver and cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
12.
Insert the appropriate cable into the cable connector ports on each PIC on the FPC.
13.
Arrange the cable in the standard or extended cable manager to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
14.
Use one of the following methods to bring the FPC online:
Copyright © 2017, Juniper Networks, Inc.
365
MX960 3D Universal Edge Router Hardware Guide
• Press and hold the FPC online/offline button until the green OK LED next to the button lights steadily, in about 5 seconds. The LEDs and online/offline button for each FPC are located directly above it on the craft interface.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer .
CAUTION: After the OK LED lights steadily, wait at least 30 seconds before removing the FPC again, removing an FPC from a different slot, or inserting an FPC in a different slot.
You can also verify correct FPC and PIC functioning by issuing the show chassis fpc and show chassis fpc pic-status commands described in
“Maintaining MX960 FPCs” on page 455
and
“Maintaining MX960 PICs” on page 466
.
Figure 150: Installing an FPC
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK
FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK
FAIL
5
ONLINE
RE0
OK
FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
ALAR M
OK FAIL
NC
C NO NC C
NO
OK FAIL
8
ONLINE
9
ONLINE
OK
FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
366
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
•
Replacing an MX960 PIC on page 382
•
Maintaining MX960 FPCs on page 455
•
Holding an MX960 FPC on page 457
•
Storing an MX960 FPC on page 461
Replacing an MX960 MIC
1.
Removing an MX960 MIC on page 367
2.
Installing an MX960 MIC on page 370
3.
Installing an MX960 Dual-Wide MIC on page 373
Removing an MX960 MIC
MICs are hot-insertable and hot-removable. When you remove a MIC, the router continues to function, although the MIC interfaces being removed no longer function.
The MICs are located in the MPCs installed in the front of the router. A MIC weighs less than 2 lb (0.9 kg).
To remove a MIC (see
and
):
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
MIC. If the MIC connects to fiber-optic cable, have ready a rubber safety cap for each transceiver and cable.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Use one of the following methods to take the MIC offline:
• Press its online/offline button. Use a narrow-ended tool that fits inside the opening that leads to the button. Press the button until the MIC OK/FAIL LED goes off.
• Issue the following CLI command: user@host> request chassis mic fpc-slot mpc-slot mic-slot mic-slot offline
For more information about the command, see the CLI Explorer .
4.
Label the cables connected to the MIC so that you can later reconnect each cable to the correct MIC.
5.
Disconnect the cables from the MIC. If the MIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
Copyright © 2017, Juniper Networks, Inc.
367
MX960 3D Universal Edge Router Hardware Guide
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Arrange the cable to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
7.
On the MPC, pull the ejector lever that is adjacent to the MIC you are removing away from the MPC faceplate. This disconnects the MIC from the MPC.
NOTE: To remove a dual-wide MIC that takes up both MIC slots, you must pull both ejector levers away from the MPC faceplate.
8.
Grasp the handles on the MIC faceplate, and slide the MIC out of the MPC card carrier.
Place it in the electrostatic bag or on the antistatic mat.
9.
If you are not reinstalling a MIC into the emptied MIC slot within a short time, install a blank MIC panel over the slot to maintain proper airflow in the MPC card cage.
368 Copyright © 2017, Juniper Networks, Inc.
Figure 151: Removing a MIC
Chapter 25: Replacing Line Card Components
Copyright © 2017, Juniper Networks, Inc.
369
MX960 3D Universal Edge Router Hardware Guide
Figure 152: Removing a Dual-Wide MIC
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK
FAIL OK
FAIL
3
ONLINE
4
ONLINE
0
FAN
1
OK
FAIL
5
ONLINE
RE0
OK
FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK FAIL
NC C NO NC
C NO
OK FAIL
8
ONLINE
9
ONLINE
OK
FAIL
10
ONLINE
OK FAIL
11
ONLINE
Ejector
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Ejector
Installing an MX960 MIC
To install a MIC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
If you have used a dual-wide MIC and are now replacing it with two “single” MICs, install the septum (see
a.
Place the MPC on a flat surface (if necessary, remove the MPC from the router as described in
“Removing an MX960 MPC” on page 377 ).
b.
Position the septum in the center of the MPC so that it lines up with holes labeled
S on the top of the MPC.
c.
Insert a screw into each of the two holes labeled S , and then tighten completely.
370 Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components d.
On the bottom of the MPC, insert a screw into each of the four holes labeled S , and then tighten completely.
e.
Install the MPC as described in
“Installing an MX960 MPC” on page 284 .
Figure 153: Installing the Septum
Slide septum into MPC.
Install two screws.
Install four screws on bottom.
3.
If the MIC uses fiber-optic cable, verify that a rubber safety cap is over each transceiver on the faceplate. Install a cap if necessary.
4.
On the MPC, pull the ejector lever that is adjacent to the MIC you are installing away from the MPC faceplate.
5.
Align the rear of the MIC with the guides located at the corners of the MIC slot.
6.
Slide the MIC into the MPC until it is firmly seated in the MPC.
CAUTION: Slide the MIC straight into the slot to avoid damaging the components on the MIC.
7.
Verify that the ejector lever is engaged by pushing it towards the MPC faceplate.
8.
If the MIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
Copyright © 2017, Juniper Networks, Inc.
371
MX960 3D Universal Edge Router Hardware Guide
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
9.
Insert the appropriate cables into the cable connectors on the MIC.
10.
Arrange each cable to prevent the cable from dislodging or developing stress points.
Secure the cable so that it is not supporting its own weight as it hangs to the floor.
Place excess cable out of the way in a neatly coiled loop.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
11.
Use one of the following methods to bring the MIC online:
• Press its online/offline button. Use a narrow-ended tool that fits inside the opening that leads to the button. Press the button until the MIC OK/FAIL LED lights green.
• Issue the following CLI command: user@host> request chassis mic fpc-slot mpc-slot mic-slot mic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning status LED confirms that the MIC is online. You can also verify correct MIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining MX960 MICs” on page 462
.
372 Copyright © 2017, Juniper Networks, Inc.
Figure 154: Installing a MIC
Chapter 25: Replacing Line Card Components
Installing an MX960 Dual-Wide MIC
To install a dual-wide MIC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Remove the septum, if necessary (see
a.
Place the MPC on a flat surface (if necessary, remove the MPC from the router as described in
“Removing an MX960 MPC” on page 377 ).
b.
Remove the four screws labeled S on the bottom of the MPC.
c.
Remove the two screws labeled S on the top of the MPC.
Copyright © 2017, Juniper Networks, Inc.
373
MX960 3D Universal Edge Router Hardware Guide d.
Slide the septum towards you and out of the MPC.
e.
Store the septum and screws for later use.
f.
Install the MPC as described in
“Installing an MX960 MPC” on page 284 .
Figure 155: Removing the Septum
Remove four screws on bottom.
Remove two screws on top.
Slide septum forward.
MPC
3.
If the MIC uses fiber-optic cable, verify that a rubber safety cap is over each transceiver on the faceplate. Install a cap if necessary.
4.
Pull the ejector lever above both MIC slots away from the router.
5.
Align the rear of the MIC with the guides located at the corners of the MIC slot.
6.
Slide the MIC into the MIC slot until it is firmly seated in the chassis.
CAUTION: Slide the MIC straight into the slot to avoid damaging the components on the MIC.
7.
Verify that the ejector levers are engaged by pushing them toward the router.
8.
If the MIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
374 Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
9.
Insert the appropriate cables into the cable connectors on the MIC.
10.
Arrange each cable to prevent the cable from dislodging or developing stress points.
Secure the cable so that it is not supporting its own weight as it hangs to the floor.
Place excess cable out of the way in a neatly coiled loop.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
11.
Use one of the following methods to bring the MIC online:
• Press its online/offline button. Use a narrow-ended tool that fits inside the opening that leads to the button. Press the button until the MIC OK/FAIL LED lights green.
• Issue the following CLI command: user@host> request chassis mic fpc-slot mpc-slot mic-slot mic-slot online
The normal functioning status LED confirms that the MIC is online. You can also verify correct MIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining MX960 MICs” on page 462
.
Copyright © 2017, Juniper Networks, Inc.
375
MX960 3D Universal Edge Router Hardware Guide
Figure 156: Installing a Dual-Wide MIC
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
FAN
0
1
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK
FAIL
0
ONLINE
1
ONLINE
OK
FAIL
2 6
ONLINE
OK
FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK FAIL
NC C
NO NC
OK FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK
FAIL
11
ONLINE
Dual-wide MIC
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Related
Documentation
•
MX960 Modular Interface Card Description on page 82
•
Maintaining MX960 MICs on page 462
•
Troubleshooting the MX960 MICs on page 495
•
Removing an MX960 MPC on page 377
• Preventing Electrostatic Discharge Damage to an MX960 Router
Replacing an MX960 MPC
1.
Removing an MX960 MPC on page 377
2.
Installing an MX960 MPC on page 379
376 Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
Removing an MX960 MPC
When you remove an MPC, the router continues to function, although the MIC interfaces installed on the MPC being removed no longer function.
An MPC installs vertically in the front of the router. The MPCs are hot-insertable and hot-removable. A fully configured MPC can weigh up to 18.35 lb (8.3 kg). Be prepared to accept its full weight.
To remove an MPC (see
1.
Have ready a replacement MPC or DPC blank panel and an antistatic mat for the MPC.
Also have ready rubber safety caps for each MIC using an optical interface on the MPC that you are removing.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Label the cables connected to each MIC on the MPC so that you can later reconnect the cables to the correct MICs.
4.
Use one of the following methods to take the MPC offline:
• Press and hold the corresponding online button on the craft interface. The green
OK/FAIL LED next to the button begins to blink. Hold the button down until the LED goes off.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number offline
For more information about the command, see the CLI Explorer .
5.
Disconnect the cables from the MICs installed in the MPC.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
Copyright © 2017, Juniper Networks, Inc.
377
MX960 3D Universal Edge Router Hardware Guide
6.
If a MIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
7.
Arrange the disconnected cables in the cable manager to prevent the cables from developing stress points.
8.
Simultaneously turn both the ejector handles counterclockwise to unseat the MPC.
9.
Grasp the handles, and slide the MPC straight out of the card cage halfway.
10.
Place one hand around the front of the MPC (the MIC housing) and the other hand under it to support it. Slide the MPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.
CAUTION: The weight of the MPC is concentrated in the back end. Be prepared to accept the full weight—up to 18.35 lb (8.3 kg)—as you slide the MPC out of the chassis.
When the MPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
Do not stack MPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.
11.
If necessary, remove each installed MIC from the MPC.
12.
After you remove each MIC, immediately place it on an antistatic mat or in an electrostatic bag.
13.
If you are not reinstalling an MPC into the emptied line card slots within a short time, install a blank DPC panel over each slot to maintain proper airflow in the card cage.
CAUTION: After removing an MPC from the chassis, wait at least 30 seconds before reinserting it or inserting an MPC into a different slot.
378 Copyright © 2017, Juniper Networks, Inc.
Figure 157: Removing an MPC
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
RE0
OK FAIL
MASTER
ONLINE
OFFLINE
RE1
OK
FAIL
0
ONLINE
1
ONLINE
OK
FAIL
2 6
ONLINE
OK
FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK FAIL
NC C
NO NC
OK FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK
FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Chapter 25: Replacing Line Card Components
Installing an MX960 MPC
An MPC installs vertically in the front of the router. The MPCs are hot-insertable and hot-removable. A fully configured MPC can weigh up to 18.35 lb (8.3 kg). Be prepared to accept its full weight.
To install an MPC (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Place the MPC on an antistatic mat.
3.
Take each MIC to be installed in the replacement MPC out of its electrostatic bag, and identify the slot on the MPC where it will be connected.
4.
Verify that each fiber-optic MIC has a rubber safety cap covering the MIC transceiver.
If it does not, cover the transceiver with a safety cap.
5.
Install each MIC into the appropriate slot on the MPC.
Copyright © 2017, Juniper Networks, Inc.
379
MX960 3D Universal Edge Router Hardware Guide
380
6.
Locate the slot in the card cage in which you plan to install the MPC.
7.
Orient the MPC so that the faceplate faces you.
8.
Lift the MPC into place, and carefully align the sides of the MPC with the guides inside the card cage.
CAUTION: When the MPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.
9.
Slide the MPC all the way into the card cage until you feel resistance.
10.
Grasp both ejector handles, and rotate them clockwise simultaneously until the MPC is fully seated.
11.
If any of the MICs on the MPC connect to fiber-optic cable, remove the rubber safety cap from each transceiver and cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
12.
Insert the appropriate cable into the cable connector ports on each MIC on the MPC.
Secure the cables so that they are not supporting their own weight. Place excess cable out of the way in a neatly coiled loop, using the cable management system. Placing fasteners on a loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
13.
Use one of the following methods to bring the MPC online:
• Press and hold the corresponding MPC online button on the craft interface until the green OK/FAIL LED next to the button lights steadily, in about 5 seconds.
• Issue the following CLI command:
Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components user@host> request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer .
CAUTION: After the OK/FAIL LED lights steadily, wait at least 30 seconds before removing the MPC again, removing an MPC from a different slot, or inserting an MPC in a different slot.
You can also verify correct MPC and MIC functioning by issuing the show chassis fpc and show chassis fpc pic-status commands described in
“Maintaining MX960 MPCs” on page 463
and
“Maintaining MX960 MICs” on page 462
.
Figure 158: Installing an MPC
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK
FAIL
NC C NO
NC
OK
FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
MX960 Modular Port Concentrator Description on page 89
•
Replacing an MX960 MIC on page 367 .
•
Maintaining MX960 MPCs on page 463
•
Troubleshooting the MX960 MPCs on page 496
Copyright © 2017, Juniper Networks, Inc.
381
MX960 3D Universal Edge Router Hardware Guide
Replacing an MX960 PIC
•
Removing an MX960 PIC on page 382
•
Installing an MX960 PIC on page 384
Removing an MX960 PIC
PICs are hot-insertable and hot-removable. When you remove a PIC, the router continues to function, although the PIC interfaces being removed no longer function.
The PICs are located in the FPCs installed in the front of the router. A PIC weighs less than 2 lb (0.9 kg).
To remove a PIC (see
1.
Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the
PIC. If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each transceiver and cable.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Use one of the following methods to take the PIC offline:
• Press its online/offline button. For a PIC installed in FPC3, use a narrow-ended tool that fits inside the opening that leads to the button. Press and hold the button until the PIC LED goes out (about 5 seconds).
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see the CLI Explorer .
4.
Label the cables connected to the PIC so that you can later reconnect each cable to the correct PIC.
5.
Disconnect the cables from the PIC. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
382 Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
6.
Arrange the cable in the standard or extended cable manager to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
7.
For an FPC3 PIC, loosen the captive screw at the bottom of the PIC faceplate, then twist the ejector handle at the top of the faceplate counterclockwise to unseat the
PIC.
8.
Slide the PIC out of the FPC card carrier and place it in the electrostatic bag or on the antistatic mat.
9.
If you are not reinstalling a PIC into the emptied PIC slot within a short time, install a blank PIC panel over the slot to maintain proper airflow in the FPC card cage.
Figure 159: Removing a PIC
Copyright © 2017, Juniper Networks, Inc.
383
MX960 3D Universal Edge Router Hardware Guide
Installing an MX960 PIC
To install a PIC (see
):
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
If the PIC uses fiber-optic cable, verify that a rubber safety cap is over each transceiver on the faceplate. Install a cap if necessary.
3.
Align the notches in the connector at the rear of the PIC with the notches in the PIC slot in the FPC and then slide the PIC in until it lodges firmly in the FPC.
CAUTION: Slide the PIC straight into the slot to avoid damaging the components on the bottom of the PIC.
4.
For an FPC3 PIC, turn the ejector handle at the top of the PIC faceplate clockwise, then tighten the captive screw at the bottom of the faceplate to secure the PIC in the
FPC.
5.
If the PIC uses fiber-optic cable, remove the rubber safety cap from each transceiver and the end of each cable.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
6.
Insert the appropriate cables into the cable connectors on the PIC.
7.
Arrange the cable in the standard or extended cable manager to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
384 Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
8.
Use one of the following methods to bring the PIC online:
• Press the PIC offline/online button until the PIC LED lights green. For a PIC installed in FPC3, use a narrow-ended tool that fits inside the opening that leads to the button.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning status LED confirms that the PIC is online. You can also verify correct PIC functioning by issuing the show chassis fpc pic-status command described in
“Maintaining MX960 PICs” on page 466 .
Figure 160: Installing a PIC
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing an MX960 FPC on page 361
•
Troubleshooting the MX960 PICs on page 494
•
Maintaining MX960 PICs on page 466
•
MX960 PIC Serial Number Label on page 516
Copyright © 2017, Juniper Networks, Inc.
385
MX960 3D Universal Edge Router Hardware Guide
•
MX960 PIC Description on page 66
Replacing a Cable on an MX960 DPC, MPC, MIC, or PIC
•
Removing a Cable on an MX960 DPC, MPC, MIC, or PIC on page 386
•
Installing a Cable on an MX960 DPC, MPC, MIC, or PIC on page 387
Removing a Cable on an MX960 DPC, MPC, MIC, or PIC
Removing and installing cables on a DPC, MPC, MIC, or PIC does not affect router function, except that the component does not receive or transmit data while its cable is disconnected.
To remove a fiber-optic cable:
1.
If the component connects to fiber-optic cable, have ready a rubber safety cap for each cable and transceiver.
2.
If removing all cables connected to the component, use one of the following methods to take the component offline:
• To take a DPC or an MPC offline:
• Press and hold the corresponding online button on the craft interface. The green
OK LED next to the button begins to blink. Hold the button down until the LED goes off.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number offline
For more information about the command, see the CLI Explorer .
• To take a PIC offline:
• Press the online/offline button on the PIC. For a PIC installed in an FPC3, use a narrow-ended tool that fits inside the opening that leads to the button. Press and hold the button until the PIC LED goes out (about 5 seconds).
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline
For more information about the command, see the CLI Explorer .
• To take a MIC offline:
• Press the online/offline button on the MIC. Use a narrow-ended tool that fits inside the opening that leads to the button. Press and hold the button until the
MIC LED goes off (about 5 seconds).
• Issue the following CLI command: user@host> request chassis mic fpc-slot mpc-slot pic-slot mic-slot offline
386 Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components
For more information about the command, see the CLI Explorer .
3.
Unplug the cable from the cable connector port. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
4.
Remove the cable from the cable manager and detach it from the destination port.
Installing a Cable on an MX960 DPC, MPC, MIC, or PIC
To install a cable:
1.
Have ready a length of the type of cable used by the component. For cable specifications, see the MX Series Interface Module Reference .
2.
If the cable connector port is covered by a rubber safety cap, remove the cap.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
CAUTION: Do not leave a fiber-optic transceiver uncovered except when you are inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.
3.
Insert the cable connector into the cable connector port on the component faceplate.
4.
Arrange the cable in the standard or extended cable manager to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.
Copyright © 2017, Juniper Networks, Inc.
387
MX960 3D Universal Edge Router Hardware Guide
388
CAUTION: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.
5.
Insert the other end of the cable into the destination port.
6.
Repeat the previous steps for any additional cables.
7.
If the component is offline (its failure indicator LED is lit), use one of the following methods to bring it online.
• To bring a DPC or MPC online:
• Press and hold the corresponding online button on the craft interface until the green OK LED next to the button lights steadily, in about 5 seconds.
• Issue the following CLI command: user@host> request chassis fpc slot slot-number online
For more information about the command, see the CLI Explorer .
• To bring a PIC online:
• Press the PIC offline/online button until the PIC LED lights green. For a PIC installed in FPC3, use a narrow-ended tool that fits inside the opening that leads to the button.
• Issue the following CLI command: user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer .
• To bring a MIC online:
• Press the MIC offline/online button until the MIC LED lights green.
• Issue the following CLI command: user@host> request chassis mic fpc-slot mpc-slot pic-slot mic-slot online
For more information about the command, see the CLI Explorer .
The normal functioning indicator LED confirms that the component is online. You can also verify correct DPC or MPC functioning by issuing the show chassis fpc command
Copyright © 2017, Juniper Networks, Inc.
Chapter 25: Replacing Line Card Components or the correct PIC or MIC functioning by issuing the show chassis fpc pic-status command.
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing an MX960 PIC on page 382
•
Replacing an MX960 DPC on page 355
•
Replacing an SFP or XFP Transceiver on an MX960 DPC, MPC, MIC, or PIC on page 437
Copyright © 2017, Juniper Networks, Inc.
389
MX960 3D Universal Edge Router Hardware Guide
390 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 26
Replacing Power System Components
•
Replacing an MX960 AC Power Supply on page 391
•
Replacing an MX960 DC Power Supply on page 395
•
Replacing an MX960 AC Power Supply Cord on page 403
•
Replacing an MX960 DC Power Supply Cable on page 404
Replacing an MX960 AC Power Supply
1.
Removing a Normal Capacity MX960 AC Power Supply on page 391
2.
Installing an MX960 AC Power Supply on page 394
Removing a Normal Capacity MX960 AC Power Supply
Before you remove a power supply, be aware of the following:
NOTE: The minimum number of power supplies must be present in the router at all times.
CAUTION: To maintain proper cooling and prevent thermal shutdown of the operating power supply unit, each power supply slot must contain either a power supply or a blank panel. If you remove a power supply, you must install a replacement power supply or a blank panel shortly after the removal.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
Copyright © 2017, Juniper Networks, Inc.
391
MX960 3D Universal Edge Router Hardware Guide
To remove an AC power supply (see
1.
Switch off the dedicated customer site circuit breaker for the power supply, and remove the power cord from the AC power source. Follow the ESD and disconnection instructions for your site.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Move the AC input switch in the chassis above the power supply to the off ( O ) position.
4.
While grasping the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops.
5.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
6.
Pull the power supply straight out of the chassis.
WARNING: Do not touch the power connector on the top of the power supply (see
). It can contain dangerous voltages.
392 Copyright © 2017, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Figure 161: Removing an AC Power Supply
Figure 162: Top of the Power Supply Showing Midplane Connector
Connector end of AC or DC power supply
Copyright © 2017, Juniper Networks, Inc.
393
MX960 3D Universal Edge Router Hardware Guide
Installing an MX960 AC Power Supply
To install an AC power supply (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Move the AC input switch in the chassis above the empty power supply slot to the off
( O ) position.
3.
Ensure that the release lever below the empty power supply slot is locked in the counterclockwise position (see
).
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
4.
Using both hands, slide the power supply straight into the chassis until the power supply is fully seated in the chassis slot. The power supply faceplate should be flush with any adjacent power supply faceplates.
The small tab on the metal housing that is controlled by the release lever must be inside of the corresponding slot at the bottom of the power supply (see
). This tab is used to pull the power supply down in the chassis slot, prior to removing the power supply.
5.
While firmly pushing the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever clockwise until it stops.
6.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
7.
Move the AC input switch in the chassis above the power supply to the on ( — ) position and observe the status LEDs on the power supply faceplate. If the power supply is correctly installed and functioning normally, the AC OK and DC OK LEDs light steadily, and the PS FAIL LED is not lit.
394 Copyright © 2017, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Figure 163: Installing an AC Power Supply
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Connecting an MX960 AC Power Supply Cord on page 243
•
Disconnecting an MX960 AC Power Supply Cord on page 403
•
MX960 AC Power Supply Description on page 98
• MX960 AC Power Electrical Safety Guidelines and Warnings
Replacing an MX960 DC Power Supply
1.
Removing an MX960 DC Power Supply on page 395
2.
Installing an MX960 DC Power Supply on page 399
Removing an MX960 DC Power Supply
Before you remove a power supply, be aware of the following:
Copyright © 2017, Juniper Networks, Inc.
395
MX960 3D Universal Edge Router Hardware Guide
NOTE: The minimum number of power supplies must be present in the router at all times.
WARNING: Before performing DC power procedures, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.
CAUTION: To maintain proper cooling and prevent thermal shutdown of the operating power supply unit, each power supply slot must contain either a power supply or a blank panel. If you remove a power supply, you must install a replacement power supply or a blank panel shortly after the removal.
NOTE: After powering off a power supply, wait at least 60 seconds before turning it back on.
To remove a DC power supply (see
1.
Switch off the dedicated customer site circuit breaker for the power supply being removed. Follow your site's procedures for ESD.
2.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
3.
Verify that the INPUT OK LEDs on the power supply to be removed are not lit.
4.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
5.
Move the DC circuit breaker on the power supply faceplate to the off ( O ) position.
6.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
7.
Remove the nut and washer from each of the terminal studs. (Use a 7/16-in.
[11 mm] nut driver or socket wrench.)
8.
Remove the cable lugs from the terminal studs.
396 Copyright © 2017, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
9.
Loosen the captive screw on the cable restraint on the lower edge of the power supply faceplate.
10.
Carefully move the power cables out of the way.
11.
While grasping the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops.
12.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
13.
Pull the power supply straight out of the chassis.
WARNING: Do not touch the power connector on the top of the power supply (see
Figure 165 on page 398 ). It can contain dangerous voltages.
Copyright © 2017, Juniper Networks, Inc.
397
MX960 3D Universal Edge Router Hardware Guide
Figure 164: Removing a DC Power Supply from the MX960 Router
398
Figure 165: Top of the Power Supply Showing Midplane Connector
Connector end of AC or DC power supply
Copyright © 2017, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Installing an MX960 DC Power Supply
WARNING: Before performing DC power procedures, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.
To install a DC power supply (see
1.
Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Move the DC circuit breaker on the power supply faceplate to the off ( O ) position.
4.
Ensure that the release lever below the empty power supply slot is locked in the counterclockwise position (see
).
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
5.
Using both hands, slide the power supply straight into the chassis until the power supply is fully seated in the chassis slot. The power supply faceplate should be flush with any adjacent power supply faceplates.
The small tab on the metal housing that is controlled by the release lever must be inside of the corresponding slot at the bottom of the power supply (see
). This tab is used to pull the power supply down in the chassis slot, prior to removing the power supply.
6.
While firmly pushing the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever clockwise until it stops.
7.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
8.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
9.
Remove the nut and washer from each of the terminal studs.
Copyright © 2017, Juniper Networks, Inc.
399
MX960 3D Universal Edge Router Hardware Guide
10.
Secure each power cable lug to the terminal studs, first with the split washer, then with the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut (see
). Do not overtighten the nut. (Use a
7/16-in. (11 mm) torque-controlled driver or socket wrench.) a. Attach the positive (+) DC source power cable lug to the RTN (return) terminal.
b. Attach the negative (–) DC source power cable lug to the –48V (input) terminal.
CAUTION: Ensure that each power cable lug seats flush against the surface of the terminal block as you are tightening the nuts. Ensure that each nut is properly threaded onto the terminal stud. The nut should be able to spin freely with your fingers when it is first placed onto the terminal stud.
Applying installation torque to the nut when improperly threaded may result in damage to the terminal stud.
CAUTION: The maximum torque rating of the terminal studs on the DC power supply is 58 lb-in. (6.5 Nm). The terminal studs may be damaged if excessive torque is applied. Use only a torque-controlled driver or socket wrench to tighten nuts on the DC power supply terminal studs.
CAUTION: You must ensure that power connections maintain the proper polarity. The power source cables might be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color coding used by the external DC power source at your site determines the color coding for the leads on the power cables that attach to the terminal studs on each power supply.
NOTE: The DC power supplies in slots PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A , and the DC power supplies in PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B . This configuration provides the commonly deployed A/B feed redundancy for the system. For information about connecting to DC power sources, see
“Electrical Specifications for the MX960 DC Power Supply” on page 169 .
11.
Loosen the captive screw on the cable restraint on the lower edge of the power supply faceplate.
12.
Route the positive and negative DC power cables through the left and right sides of the cable restraint.
400 Copyright © 2017, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
13.
Tighten the cable restraint captive screw to hold the power cables in place.
WARNING: Once the DC power supply is connected, the cable will be blocking the PEM slot label. Make sure and note or mark the PEM slot once the power supply is connected.
14.
Replace the clear plastic cover over the terminal studs on the faceplate.
15.
Verify that the power cabling is correct, that the cables are not touching, and that they do not block access to router components or drape where people could trip on them.
16.
Switch on the dedicated customer site circuit breaker.
17.
Verify that the INPUT OK LED on the power supply is lit steadily.
18.
On each of the DC power supplies, switch the DC circuit breaker to the center position before moving it to the on ( | ) position.
NOTE: The circuit breaker may bounce back to the off ( O ) position if you move the breaker too quickly.
19.
Verify that the BREAKER ON LED is lit steadily.
20.
Verify that the PWR OK LED is lit steadily.
Copyright © 2017, Juniper Networks, Inc.
401
MX960 3D Universal Edge Router Hardware Guide
Figure 166: Installing a DC Power Supply
402 Copyright © 2017, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Figure 167: Connecting DC Power to the MX960 Router
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Electrical Specifications for the MX960 DC Power Supply on page 169
•
MX960 DC Power Supply on page 104
• MX960 DC Power Electrical Safety Guidelines
•
Connecting an MX960 DC Power Supply Cable on page 244
•
Disconnecting an MX960 DC Power Supply Cable on page 405
Replacing an MX960 AC Power Supply Cord
1.
Disconnecting an MX960 AC Power Supply Cord on page 403
2.
Connecting an MX960 AC Power Supply Cord on page 404
Disconnecting an MX960 AC Power Supply Cord
To disconnect the AC power cord:
1.
Move the AC input switch, which is to the right of the appliance inlet on the chassis, to the off ( O ) position.
2.
Unplug the power cord from the power source receptacle.
Copyright © 2017, Juniper Networks, Inc.
403
MX960 3D Universal Edge Router Hardware Guide
3.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
4.
Unplug the power cord from the appliance inlet on the power supply.
Connecting an MX960 AC Power Supply Cord
To connect the AC power cord:
1.
Locate a replacement power cord with the type of plug appropriate for your geographical location (see
“AC Power Cord Specifications for the MX960 Router” on page 165
).
2.
Plug the replacement power cord into the corresponding appliance inlet located in the chassis directly above the power supply.
3.
Insert the power cord plug into an external AC power source receptacle.
NOTE: Each power supply must be connected to a dedicated AC power feed and a dedicated customer site circuit breaker. We recommend that you use a 15 A (250 VAC) minimum, or as required by local code.
4.
Dress the power cord appropriately. Verify that the power cord does not block the air exhaust and access to router components, or drape where people could trip on it.
5.
Move the AC input switch in the chassis above the power supply to the on ( — )position and observe the status LEDs on the power supply faceplate. If the power supply is correctly installed and functioning normally, the AC OK and DC OK LEDs light steadily, and the PS FAIL LED is not lit.
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
AC Power Cord Specifications for the MX960 Router on page 165
•
MX960 AC Power Supply Description on page 98
• MX960 AC Power Electrical Safety Guidelines and Warnings
•
Replacing an MX960 AC Power Supply on page 391
Replacing an MX960 DC Power Supply Cable
1.
Disconnecting an MX960 DC Power Supply Cable on page 405
2.
Connecting an MX960 DC Power Supply Cable on page 406
404 Copyright © 2017, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Disconnecting an MX960 DC Power Supply Cable
WARNING: Before performing DC power procedures, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.
To disconnect a power cable for a DC power supply:
1.
Switch off the dedicated customer site circuit breaker for the power supply being removed. Follow your site's procedures for ESD.
2.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
3.
Verify that the INPUT OK LED on the power supply is not lit.
4.
Remove the power cable from the external DC power source.
5.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
6.
Move the DC circuit breaker on the power supply faceplate to the off ( O ) position.
7.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
8.
Remove the nut and washer from each of the terminal studs. (Use a 7/16-in.
[11 mm] nut driver or socket wrench.)
9.
Remove the cable lug from the terminal studs.
10.
Loosen the captive screw on the cable restraint on the lower edge of the power supply faceplate.
11.
Carefully move the power cable out of the way.
Copyright © 2017, Juniper Networks, Inc.
405
MX960 3D Universal Edge Router Hardware Guide
Connecting an MX960 DC Power Supply Cable
WARNING: Before performing DC power procedures, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.
To connect a power cable for a DC power supply:
1.
Locate a replacement power cable that meets the specifications defined in
Specifications for the MX960 DC Power Supply” on page 169
.
2.
Verify that a licensed electrician has attached a cable lug to the replacement power cable.
3.
Verify that the INPUT OK LED is off.
4.
Secure the power cable lug to the terminal studs, first with the split washer, then with the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut (see
Figure 76 on page 245 ). Do not overtighten the nut. (Use a 7/16-in. (11 mm)
torque-controlled driver or socket wrench.)
CAUTION: Ensure that each power cable lug seats flush against the surface of the terminal block as you are tightening the nuts. Ensure that each nut is properly threaded onto the terminal stud. The nut should be able to spin freely with your fingers when it is first placed onto the terminal stud.
Applying installation torque to the nut when improperly threaded may result in damage to the terminal stud.
CAUTION: The maximum torque rating of the terminal studs on the DC power supply is 58 lb-in. (6.5 Nm). The terminal studs may be damaged if excessive torque is applied. Use only a torque-controlled driver or socket wrench to tighten nuts on the DC power supply terminal studs.
406 Copyright © 2017, Juniper Networks, Inc.
Chapter 26: Replacing Power System Components
Figure 168: Connecting Power Cables to the DC Power Supply
Cable
Split lug
Terminal studs washer
Nut
5.
Route the power cable through the cable restraint. Make sure that the cable does not touch or obstruct any router components.
6.
Tighten the cable restraint captive screw to hold the power cables in place.
7.
Verify that the DC power cable is connected correctly, that it does not touch or block access to router components, and that it does not drape where people could trip on it.
8.
Replace the clear plastic cover over the terminal studs on the faceplate.
9.
Attach the power cable to the DC power source.
10.
Turn on the dedicated customer site circuit breaker to the power supply.
11.
Verify that the INPUT OK LED on the power supply is lit steadily.
12.
On each of the DC power supplies, switch the DC circuit breaker to the center position before moving it to the on ( | ) position.
NOTE: The circuit breaker may bounce back to the off ( O ) position if you move the breaker too quickly.
Copyright © 2017, Juniper Networks, Inc.
407
MX960 3D Universal Edge Router Hardware Guide
Observe the status LEDs on the power supply faceplate. If the power supply is correctly installed and functioning normally, the PWR OK , BRKR ON , and INPUT OK LEDs light green steadily.
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
DC Power Cable Specifications for the MX960 Router on page 185
•
MX960 DC Power Supply on page 104
• MX960 DC Power Electrical Safety Guidelines
408 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 27
Replacing Switch Fabric Components
•
Replacing an MX960 SCB on page 409
•
Upgrading an MX960 SCB to SCBE on page 428
•
Replacing an SFP or XFP Transceiver on an MX960 DPC, MPC, MIC, or PIC on page 437
Replacing an MX960 SCB
Before replacing an SCB, read the guidelines in Operating and Positioning the MX960 SCB
Ejectors .
1.
Removing an MX960 SCB on page 410
2.
Installing an MX960 SCB on page 411
3.
Upgrading an MX960 SCB to SCBE on page 413
4.
Upgrading an MX960 SCB or SCBE to SCBE2 on page 422
Copyright © 2017, Juniper Networks, Inc.
409
MX960 3D Universal Edge Router Hardware Guide
Removing an MX960 SCB
To remove an SCB (see
):
NOTE: You can remove the SCB and Routing Engine as a unit, or remove the
Routing Engine separately.
CAUTION: Before removing an SCB, ensure that you know how to operate the ejector handles properly to avoid damage to the equipment.
NOTE: You do not need to offline the host subsystem in the following scenarios:
• You are replacing an SCB installed in slot 2/6 .
• You are replacing an SCB that functions as a third SCB and no Routing
Engine is installed.
1.
Take the host subsystem offline.
NOTE: If there is only one host subsystem, taking the host subsystem offline shuts down the router and you are not required to offline the SCB.
2.
Take the SCB offline by issuing the following CLI command: user@host> request chassis cb slot slot-number offline
3.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
4.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
5.
Rotate the ejector handles simultaneously counterclockwise to unseat the SCB.
6.
Grasp the ejector handles, and slide the SCB about halfway out of the chassis.
7.
Place one hand underneath the SCB to support it, and slide it completely out of the chassis.
410 Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
8.
Place the SCB on the antistatic mat.
9.
If you are not replacing the SCB now, install a blank panel over the empty slot.
Figure 169: Removing an SCB
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK
FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK
FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK
FAIL
5
ONLINE
RE0
OK
FAIL
MASTER
ONLINE
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
ACO/LT
OK FAIL
7
ONLINE
OK FAIL
NC
C NO NC C
NO
OK FAIL
8
ONLINE
9
ONLINE
OK
FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Installing an MX960 SCB
To install an SCB (see
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Carefully align the sides of the SCB with the guides inside the chassis.
3.
Slide the SCB into the chassis until you feel resistance, carefully ensuring that it is correctly aligned.
4.
Grasp both ejector handles, and rotate them simultaneously clockwise until the SCB is fully seated.
Copyright © 2017, Juniper Networks, Inc.
411
MX960 3D Universal Edge Router Hardware Guide
412
5.
Place the ejector handles in the proper position, vertically and toward the center of the board.
6.
Check the LEDs on the SCB faceplate to verify that it is functioning normally.
• The green OK/FAIL LED should light steadily a few minutes after the SCB is installed.
• If the OK/FAIL LED is red, remove and install the SCB again. If the OK/FAIL LED still lights steadily, the SCB is not functioning properly. Contact your customer support representative.
7.
Check the status of the SCB using the show chassis environment cb command: user@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 25 degrees C / 77 degrees F
Power 1
1.2 V 1198 mV
1.5 V 1508 mV
1.8 V 1830 mV
2.5 V 5059 mV
3.3 V 6593 mV
5.0 V 5111 mV
12.0 V 12181 mV
1.25 V 1250 mV
3.3 V SM3 6587 mV
5 V RE 5078 mV
12 V RE 12026 mV
Power 2
11.3 V bias PEM 11253 mV
4.6 V bias MidPlane 4827 mV
11.3 V bias FPD 11408 mV
11.3 V bias POE 0 11446 mV
11.3 V bias POE 1 11408 mV
Bus Revision 6
FPGA Revision 0
CB 1 status:
State Online Standby
Temperature 26 degrees C / 78 degrees F
Power 1
1.2 V 1211 mV
1.5 V 1517 mV
1.8 V 1817 mV
2.5 V 2507 mV
3.3 V 3312 mV
5.0 V 5136 mV
12.0 V 12142 mV
1.25 V 1260 mV
3.3 V SM3 3306 mV
5 V RE 5085 mV
12 V RE 11968 mV
Power 2
11.3 V bias PEM 11369 mV
4.6 V bias MidPlane 4814 mV
11.3 V bias FPD 11427 mV
11.3 V bias POE 0 11350 mV
11.3 V bias POE 1 11330 mV
Bus Revision 39
FPGA Revision 1
Copyright © 2017, Juniper Networks, Inc.
Figure 170: Installing an SCB
OK
FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
OK FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK FAIL
NC C NO
NC C NO
OK
FAIL
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Chapter 27: Replacing Switch Fabric Components
Upgrading an MX960 SCB to SCBE
1.
Preparing for the Upgrade on page 413
2.
Upgrading the First SCB on page 415
3.
Upgrading the SCB in the Backup Routing Engine on page 416
4.
Upgrading the SCB in the Master Routing Engine on page 418
5.
Completing the SCB Upgrade on page 420
Preparing for the Upgrade
NOTE: This topic describes the in-service upgrade of the SCB to SCBE, that is, without taking the router offline. You can perform the in-service upgrade only when the line cards installed in the MX960 are of type DPC, MS-DPC,
MPC1, MPC2, or MPC3. If other type of line cards are installed, ensure that you take the router offline before you perform the SCB to SCBE upgrade.
Copyright © 2017, Juniper Networks, Inc.
413
MX960 3D Universal Edge Router Hardware Guide
414
NOTE: Do not make other changes to the CLI during the entire upgrade process. You can ensure that you will not make such changes by opening a telnet session to the master RE CLI operational mode and issuing the configure exclusive command. This command locks the configuration procedure.
NOTE: When you are upgrading an SCB to SCBE on a MX960 router with an
MPC3 installed in it, ensure that the Junos OS Release is 12.3 or later.
TIP: To prevent traffic loss during the upgrade process, we recommend that you operate the line cards at 50% line rate. This 50% limit must be maintained per PFE on each line card.
To prepare the MX960 router for the MX SCBE upgrade:
1.
Verify that the system runs Junos OS Release 11.4 or later by issuing the show version command on the master router.
user@host> show version
Model: mx960
Junos Base OS Software Suite [11.4-20110530];
NOTE: The MX SCBE is supported only in Junos OS Release 11.4 or later.
The latest software ensures a healthy system—that is, Routing Engines, control boards, and FPCs—before the upgrade.
2.
Verify that MX SCB boards are installed by issuing the show chassis hardware command.
user@host> show chassis hardware
Item Version Part Number Serial Number Description
CB0 REV 07 710-021523 ABBC8281 MX SCB
CB1 REV 07 710-021523 ABBC8323 MX SCB
CB2 REV 07 710-021523 ABBD1410 MX SCB
SCB details are displayed as above, along with other hardware components.
3.
Establish console connections to both Routing Engines. You can use a telnet session to connect to the router console by issuing the <router name>-con command. For example, if the router name is juniper, you can connect to RE0 and RE1 consoles by issuing the telnet juniper-con and telnet juniper1-con commands.
4.
Ensure that graceful switchover (GRES), commit synchronize (required for nonstop routing), and nonstop routing (NSR) are enabled or configured by running the set
Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components chassis redundancy graceful-switchover, set system commit synchronize, set routing-options nonstop-routing commands.
NOTE: These commands are mandatory for this upgrade and may be removed, if desired, after the upgrade.
5.
Set the upgrade flag on and start the SCB upgrade by issuing the set chassis state cb-upgrade on command.
user@host# configure user@host# set chassis state cb-upgrade on user@host# commit
6.
Determine the order to replace the existing SCBs with upgraded ones. SCB 0, 1, and
2 are available for the MX960. SCB 0 is associated with RE0, SCB1 is associated with
RE1, and ; SCB 2 is the spare SCB. The SCB order for MX960 is SCB2, SCB1 (backup
Routing Engine slot), and SCB0 (Master Routing Engine slot).
NOTE: Do not add or remove any router hardware during the upgrade procedure.
Upgrading the First SCB
To upgrade the first SCB—that is—SCB2:
1.
Take the fabric plane offline by issuing the request chassis fabric plane 4 offline command.
2.
Verify that the fabric plane is offline by issuing the show chassis fabric summary command.
user@host> show chassis fabric summary
Plane State Uptime
4 Offline
5 Online 1 hour, 15 minutes, 35 seconds
Verify that the State of Plane 4 is Offline.
3.
Take the next fabric plane offline by issuing the request chassis fabric plane 5 offline command, and then verify that the fabric plane is offline by issuing the command given in Step 2.
4.
Take the SCB in slot 2 offline by issuing the request chassis cb offline slot 2 command.
Copyright © 2017, Juniper Networks, Inc.
415
MX960 3D Universal Edge Router Hardware Guide
5.
Verify that the control board is offline by issuing the show chassis environment cb 2 command: user@host> show chassis environment cb 2
CB 2 status:
State Offline
Power 1 Disabled
Power 2 Disabled
6.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
7.
Remove and replace SCB2 on the router with the SCBE.
8.
Verify that the installation is successful and the SCB is online by issuing the show chassis environment cb 2 command: user@host> show chassis environment cb 2
CB 2 status
State Online
Temperature 30 degrees C / 86 degrees F
Other details, such as, power are also displayed along with the state.
9.
Verify that the fabric planes come online correctly by issuing the show chassis fabric summary command: user@host> show chassis fabric summary
Plane State Uptime
4 Online 2 minutes, 25 seconds
5 Online 2 minutes, 15 seconds
10.
Verify the alarms by issuing the show chassis alarms command: user@host> show chassis alarms
Alarm Time Class Description
2011-06-01 13:26:56 EDT Major CB fabrics are of mixed types
2011-06-01 12:10:41 EDT Major Require a fan tray upgrade
Because only one SCB has been upgraded, the alarm indicates that the SCBs are of mixed type. This alarm is cleared after all the control boards are upgraded.
Upgrading the SCB in the Backup Routing Engine
To upgrade the SCB in the backup Routing Engine:
1.
Power down the backup Routing Engine from the master Routing Engine by issuing the request system power-off other-routing-engine command.
2.
Ensure that the Routing Engine is powered down by issuing the show chassis routing-engine 1 command. The slot of the Routing Engine may be 0 or 1, and is shown as 1 in this example:
416 Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components user@host> show chassis routing-engine 1
Routing Engine Status:
Slot 1:
Current State Present
Verify that the Current State is Present, which indicates that the Routing Engine is offline.
3.
Take the first fabric plane of the backup Routing Engine offline by issuing the request chassis fabric plane 3 offline command.
4.
Verify that the fabric plane is offline by issuing the show chassis fabric summary command.
user@host> show chassis fabric summary
Plane State Uptime
2 Online 3 minutes, 45 seconds
3 Offline
Check if the State of Plane 3 is Offline.
5.
Take the next fabric plane offline by issuing the request chassis fabric plane 2 offline command and verify that the fabric plane is offline by issuing the command in Step
4.
6.
Take the SCB in slot 1 offline by issuing the request chassis cb offline slot 1 command.
7.
Verify that the SCB is offline by issuing the show chassis environment cb 1 command: user@host> show chassis environment cb 1
CB 1 status:
State Offline
Power 1 Disabled
Power 2 Disabled
8.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
9.
Remove and replace the offline SCB on the router with the SCBE.
10.
Verify that the installation is successful and the SCB is online by issuing the show chassis environment cb 1 command: user@host> show chassis environment cb 1
CB 1 status
State Online
Temperature 30 degrees C / 86 degrees F
Other details, such as power, are also displayed along with the state.
Copyright © 2017, Juniper Networks, Inc.
417
MX960 3D Universal Edge Router Hardware Guide
418
11.
Verify that the fabric planes 2 and 3 come online correctly by issuing the show chassis fabric summary command: user@host> show chassis fabric summary
Plane State Uptime
2 Online 2 minutes, 5 seconds
3 Online 1 minutes, 55 seconds
12.
Verify that the backup routing engine is back online by issuing the show chassis routing-engine 1 command: user@host> show chassis routing-engine 1
Routing Engine Status:
Slot 1:
Current State Backup
Upgrading the SCB in the Master Routing Engine
To upgrade the SCB in the master Routing Engine slot:
1.
Ensure a Graceful RE Switchover (GRES) to gracefully switch between the master and backup Routing Engines, so that the backup RE becomes the master RE, by issuing the request chassis routing-engine master switch command.
2.
Log in to the new master Routing Engine after the switchover.
3.
Switch the configuration mode to ensure that you are still in configure exclusive mode by issuing the exit command and then the configure exclusive command, from the old master Routing Engine.
4.
Log in to the current master Routing Engine again and issue the configure exclusive command.
5.
Power down the backup Routing Engine from the master Routing Engine by issuing the request system power-off other-routing-engine command.
6.
Ensure that the Routing Engine is powered down by issuing the show chassis routing-engine 0 command. The slot of the Routing Engine may be 0 or 1, and is shown as 1 in this example: user@host> show chassis routing-engine 1
Routing Engine Status:
Slot 0:
Current State Present
Verify that the Current State is Present, which indicates that the Routing Engine is offline or powered down.
7.
Take the first fabric plane of the backup Routing Engine offline by issuing the request chassis fabric plane offline 1 command.
Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
8.
Verify that the fabric plane is offline by issuing the show chassis fabric summary command.
user@host> show chassis fabric summary
Plane State Uptime
1 Offline
2 Online 3 minutes, 25 seconds
Verify that the State of Plane 1 is Offline.
9.
Take the next fabric plane offline by issuing the request chassis fabric plane offline 0 command and verify that the fabric plane is offline by issuing the command given in
Step 2.
10.
Take the SCB in slot 0 offline by issuing the request chassis cb offline slot 0 command.
11.
Verify that the control board is offline by issuing the show chassis environment cb 0 command: user@host> show chassis environment cb 0
CB 0 status:
State Offline
Power 1 Disabled
Power 2 Disabled
12.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
13.
Remove and replace the offline SCB on the router with the SCBE.
14.
Verify that the installation is successful and the SCB is online by issuing the show chassis environment cb 0 command: user@host> show chassis environment cb 0
CB 0 status
State Online
Temperature 30 degrees C / 86 degrees F
Other details, such as power, are also displayed, along with the state.
15.
Verify that the fabric planes 0 and 1 come online correctly by issuing the show chassis fabric summary command: user@host> show chassis fabric summary
Plane State Uptime
0 Online 2 minutes, 9 seconds
1 Online 2 minutes, 2 seconds
16.
Verify that the backup Routing Engine is back online by issuing the show chassis routing-engine 0 command: user@host> show chassis routing-engine 0
Copyright © 2017, Juniper Networks, Inc.
419
MX960 3D Universal Edge Router Hardware Guide
420
Routing Engine Status:
Slot 0:
Current State Backup
17.
Verify the alarms by issuing the show chassis alarms command: user@host> show chassis alarms
Alarm Time Class Description
2011-06-01 13:26:56 EDT Major CB fabric links require upgrade/training
2011-06-01 12:10:41 EDT Major Require a fan tray upgrade
The “major” alarm has now changed from “CB fabrics are of mixed types” to “CB fabric links require upgrade/training.” This is because there is a switch control board that requires training to change links from 3G speed to 6G speed of the SCBE. This alarm is displayed until the 3G to 6G link transition is completed.
Completing the SCB Upgrade
To complete the procedure after upgrading the SCBs:
1.
Verify that any Modular Port Concentrator (MPC) is running at 3G instead of 6G by issuing the request chassis fabric upgrade-bandwidth info command: user@host> request chassis fabric upgrade-bandwidth info
Slot State
0 Upgrade not supported
1 Upgraded
2 Empty
3 Empty
4 Empty
5 Empty
6 Empty
7 Empty
The results indicate that slot 0 does not support the upgrade and slot 1 needs upgrade.
NOTE: The SCBE line card supports only DPC, MS-DPC, MPC1, MPC2, and
MPC3 line cards for the upgrade-bandwidth command. If line cards that do not support the upgrade-bandwidth command option are present in the chassis during the SCB to SCBE upgrade, the request chassis fabric upgrade-bandwidth commands will return Upgrade not supported for the slot(s) that contain the unsupported line card(s).
2.
Upgrade the bandwidth of all MPCs by issuing the request chassis fabric upgrade-bandwidth fpc all command. If you want to control the MPC line card upgrade, go to Step 3.
CAUTION: Use this command only if you are not concerned with the slot upgrade order or if only one old MPC is present in the chassis. Running this command may result in a loss of traffic across that MPC. Using this method
Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components may increase that loss, as it does not consider any redundancy or graceful switchover strategies that you may have configured on the system.
3.
Upgrade the MPC in slot 1 by running the request chassis fabric upgrade-bandwidth fpc slot 1 command.
4.
Verify that the MPC is upgraded by issuing the request chassis fabric upgrade-bandwidth info command: user@host> request chassis fabric upgrade-bandwidth info
Slot State
0 Upgrade not supported
1 Upgraded
2 Empty
5.
Verify the state of fabric planes for all MPCs by issuing the show chassis fabric summary command.
user@host> show chassis fabric summary
Plane State Uptime
0 Spare 21 seconds
1 Spare 12 seconds
2 Online 12 minutes
3 Online 12 minutes
4 Online 30 minutes
5 Online 30 minutes
6.
Verify the state of MPCs by issuing the show chassis fabric fpcs command.
user@host> show chassis fabric fpcs
FPC 1
PFE #0
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #1
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #2
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #3
Plane 0: Links ok
Copyright © 2017, Juniper Networks, Inc.
421
MX960 3D Universal Edge Router Hardware Guide
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
Fabric plane details of all MPCs are similarly displayed.
7.
Verify if any output of the show chassis fabric summary command shows fabric planes in 'check' state, as it indicates that the fabric plane has an error. You can try to recover the fabric plane to normal operation by issuing the request chassis fabric plane <#> offline command, followed by the request chassis fabric plane <#> online command, where <#> equals the fabric plane in error.
NOTE: After you issue the request chassis fabric plane <#> offline and request chassis fabric plane <#> online commands, issue the show chassis fabric summary command to verify that the fabric plane errors are rectified and to verify the current state of the fabric planes.
8.
Verify that the major alarms are displayed by issuing the show chassis alarms command: user@host> show chassis alarms
Alarm Time Class Description
2011-06-01 13:37:43 EDT Minor Require a fan tray upgrade
2011-06-01 13:37:26 EDT Minor Backup RE Active
The major alarms are not displayed anymore, and the upgrade is successfully completed.
9.
Disable the upgrade configuration by issuing the set chassis state cb-upgrade off command and then the commit command.
10.
You can delete that command by issuing the delete chassis state cb-upgrade command and then the commit command.
11.
Verify the SCBs before you finish by issuing the show chassis hardware command: user@host> show chassis hardware
Item Version Part Number Serial Number Description
CB0 REV 02 750-031391 YE8505 Enhanced MX SCB
CB1 REV 07 710-031391 YL6769 Enhanced MX SCB
CB2 REV 07 710-031391 YE8492 Enhanced MX SCB
You can see that the MX960 now has MX SCBEs.
Upgrading an MX960 SCB or SCBE to SCBE2
Consider the following scenarios when upgrading an MX960 SCB or SCBE to SCBE2:
422 Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
Scenario 1: SCBE2; Routing Engine (RE) with Junos OS Release 13.3R1 or later installed.
• Replace the SCBs. Ensure that you replace the REs at the same time.
• Ensure that Enhanced IP or Enhanced Ethernet Network Services mode is configured before you power on the router.
Scenario 2: SCB or SCBE; existing Routing Engine with a Junos OS Release 13.3R1 or earlier installed.
• Upgrade the Routing Engine ( RE0 and RE1 ) software to Junos OS Release 13.3 or later.
• Configure Enhanced IP or Enhanced Ethernet Network Services mode.
• Replace the SCBs. Ensure that you replace the SCBs at the same time.
Scenario 3: Failed SCB or SCBE; Routing Engine with a Junos OS Release 13.3R1 or earlier installed.
• Upgrade the software on the Routing Engine hosting the failed SCB or SCBE with Junos
OS Release 13.3R1 or later.
• Replace the SCBs. Ensure that you replace the SCBs at the same time.
• Upgrade the software on the Routing Engine hosting the SCBE2 with Junos OS Release
13.3R1 or later.
• Configure Enhanced IP or Enhanced Ethernet Network Services mode.
To upgrade the SCB or SCBE to SCBE2, perform the following steps:
NOTE: You cannot upgrade to SCBE2 without powering off the MX960 router.
1.
Preparing the MX960 Router for SCBE2 Upgrade on page 423
2.
Powering Off the MX960 Router on page 424
3.
Removing an MX960 Routing Engine from an SCB or SCBE on page 425
4.
Replacing the SCB or SCBE with SCBE2 on page 425
5.
Installing an MX960 Routing Engine into an SCBE2 on page 425
6.
Powering On the MX960 Router on page 426
7.
Completing the SCBE2 Upgrade on page 427
Preparing the MX960 Router for SCBE2 Upgrade
To prepare the MX960 router for the SCBE2 upgrade:
Copyright © 2017, Juniper Networks, Inc.
423
MX960 3D Universal Edge Router Hardware Guide
1.
Verify that the system runs Junos OS Release 13.3 or later by issuing the show version command on the master router.
user@host> show version
Model: mx960
Junos Base OS Software Suite [13.3-yyyymmdd];
...
NOTE: The SCBE2 is supported only on:
• Junos OS Release 13.3 or later
• Network Services Mode: Enhanced-IP
The latest software ensures a healthy system—that is, a system that comprises Routing
Engines, control boards, and FPCs—before the upgrade.
For information about how to verify and upgrade the Junos OS, see the Junos OS
Installation and Upgrade Guide .
Powering Off the MX960 Router
NOTE: After turning off the power supply, wait at least 60 seconds before turning it back on.
To power off the MX960 router:
1.
On the external management device connected to the Routing Engine, issue the request system halt both-routing-engines operational mode command. The command shuts down the Routing Engines cleanly, so that their state information is preserved.
(If the router contains only one Routing Engine, issue the request system halt command.) user@host> request system halt both-routing-engines
2.
Wait until a message appears on the console confirming that the operating system has halted.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
4.
Move the AC input switch on the chassis above the AC power supply or the DC circuit breaker on each DC power supply faceplate to the off (O) position.
424 Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
Removing an MX960 Routing Engine from an SCB or SCBE
To remove an MX960 Routing Engine from an SCB or SCBE:
1.
Remove the cables connected to the Routing Engine.
2.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Loosen the captive screws on the top and bottom of the Routing Engine.
5.
Flip the ejector handles outward to unseat the Routing Engine.
6.
Grasp the Routing Engine by the ejector handles, and slide it about halfway out of the chassis.
7.
Place one hand underneath the Routing Engine to support it, and slide it completely out of the chassis.
8.
Place the Routing Engine on the antistatic mat.
Replacing the SCB or SCBE with SCBE2
To replace the existing SCB or SCBE with SCBE2:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
2.
Remove and replace the offline SCB or SCBE on the router with SCBE2.
Installing an MX960 Routing Engine into an SCBE2
To install an MX960 Routing Engine into an SCBE2:
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
2.
Ensure that the ejector handles are not in the locked position. If necessary, flip the ejector handles outward.
3.
Place one hand underneath the Routing Engine to support it.
4.
Carefully align the sides of the Routing Engine with the guides inside the opening on the SCBE2.
Copyright © 2017, Juniper Networks, Inc.
425
MX960 3D Universal Edge Router Hardware Guide
5.
Slide the Routing Engine into the SCBE2 until you feel resistance and then press the faceplate of the Routing Engine until it engages the connectors.
6.
Press both of the ejector handles inward to seat the Routing Engine.
7.
Tighten the captive screws on the top and bottom of the Routing Engine.
8.
Connect the management device cables to the Routing Engine.
Powering On the MX960 Router
To power on the MX960 router:
1.
Verify that the power supplies are fully inserted in the chassis.
2.
Verify that each AC power cord is securely inserted into its appliance inlet.
3.
Verify that an external management device is connected to one of the Routing Engine ports ( AUX , CONSOLE , or ETHERNET ).
4.
Turn on the power to the external management device.
5.
Switch on the dedicated customer-site circuit breakers. Follow the ESD and safety instructions for your site.
6.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
7.
Move the AC input switch on the chassis above the AC power supply or the DC circuit breaker on each DC power-supply faceplate to the off (—) position.
8.
Check that the AC or the DC power supply is correctly installed and functioning normally. Verify that the AC OK and DC OK LEDs light steadily, and the PS FAIL LED is not lit.
NOTE: After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the status LEDs on the power supply and the show chassis command display—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first
60 seconds.
426 Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
If any of the status LEDs indicates that the power supply is not functioning normally, repeat the installation and cabling procedures.
9.
On the external management device connected to the Routing Engine, monitor the startup process to verify that the system has booted properly.
NOTE: If the system is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. Normally, the router boots from the Junos OS on the
CompactFlash card.
After turning on a power supply, wait at least 60 seconds before turning it off.
Completing the SCBE2 Upgrade
To complete the SCBE2 upgrade procedure:
1.
Verify that the installation is successful and the SCBE2 is online by issuing the show chassis environment cb command: user@host> show chassis environment cb 0
CB 0 status
State Online
Temperature 30 degrees C / 86 degrees F
...
user@host> show chassis environment cb 1
CB 1 status
State Online
Temperature 30 degrees C / 86 degrees F
...
Other details, such as, temperature, power, etc are also displayed along with the state.
2.
Verify that the fabric planes come online correctly by issuing the show chassis fabric summary command: user@host> show chassis fabric summary
Plane State Uptime
0 Online 2 days, 19 hours, 10 minutes, 9 seconds
1 Online 2 days, 19 hours, 10 minutes, 9 seconds
...
3.
Verify that the backup Routing Engine is back online by issuing the show chassis routing-engine 1 command: user@host> show chassis routing-engine 1
Routing Engine Status:
Slot 1:
Copyright © 2017, Juniper Networks, Inc.
427
MX960 3D Universal Edge Router Hardware Guide
Current State Backup
...
4.
Verify the SCBE2s before you finish by issuing the show chassis hardware command: user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
CB 0 REV 08 750-048307 CABC9829 Enhanced MX SCB 2
CB 1 REV 08 750-048307 CABC9828 Enhanced MX SCB 2
...
You see that the MX960 now has SCBE2s.
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
• Effect of Taking the MX960 Host Subsystem Offline
• Taking an MX960 Host Subsystem Offline
•
Maintaining the MX960 Host Subsystem on page 448
Upgrading an MX960 SCB to SCBE
1.
Preparing for the Upgrade on page 428
2.
Upgrading the First SCB on page 430
3.
Upgrading the SCB in the Backup Routing Engine on page 431
4.
Upgrading the SCB in the Master Routing Engine on page 433
5.
Completing the SCB Upgrade on page 435
Preparing for the Upgrade
NOTE: This topic describes the in-service upgrade of the SCB to SCBE, that is, without taking the router offline. You can perform the in-service upgrade only when the line cards installed in the MX960 are of type DPC, MS-DPC,
MPC1, MPC2, or MPC3. If other type of line cards are installed, ensure that you take the router offline before you perform the SCB to SCBE upgrade.
NOTE: Do not make other changes to the CLI during the entire upgrade process. You can ensure that you will not make such changes by opening a telnet session to the master RE CLI operational mode and issuing the configure exclusive command. This command locks the configuration procedure.
NOTE: When you are upgrading an SCB to SCBE on a MX960 router with an
MPC3 installed in it, ensure that the Junos OS Release is 12.3 or later.
428 Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
TIP: To prevent traffic loss during the upgrade process, we recommend that you operate the line cards at 50% line rate. This 50% limit must be maintained per PFE on each line card.
To prepare the MX960 router for the MX SCBE upgrade:
1.
Verify that the system runs Junos OS Release 11.4 or later by issuing the show version command on the master router.
user@host> show version
Model: mx960
Junos Base OS Software Suite [11.4-20110530];
NOTE: The MX SCBE is supported only in Junos OS Release 11.4 or later.
The latest software ensures a healthy system—that is, Routing Engines, control boards, and FPCs—before the upgrade.
2.
Verify that MX SCB boards are installed by issuing the show chassis hardware command.
user@host> show chassis hardware
Item Version Part Number Serial Number Description
CB0 REV 07 710-021523 ABBC8281 MX SCB
CB1 REV 07 710-021523 ABBC8323 MX SCB
CB2 REV 07 710-021523 ABBD1410 MX SCB
SCB details are displayed as above, along with other hardware components.
3.
Establish console connections to both Routing Engines. You can use a telnet session to connect to the router console by issuing the <router name>-con command. For example, if the router name is juniper, you can connect to RE0 and RE1 consoles by issuing the telnet juniper-con and telnet juniper1-con commands.
4.
Ensure that graceful switchover (GRES), commit synchronize (required for nonstop routing), and nonstop routing (NSR) are enabled or configured by running the set chassis redundancy graceful-switchover, set system commit synchronize, set routing-options nonstop-routing commands.
NOTE: These commands are mandatory for this upgrade and may be removed, if desired, after the upgrade.
5.
Set the upgrade flag on and start the SCB upgrade by issuing the set chassis state cb-upgrade on command.
Copyright © 2017, Juniper Networks, Inc.
429
MX960 3D Universal Edge Router Hardware Guide user@host# configure user@host# set chassis state cb-upgrade on user@host# commit
6.
Determine the order to replace the existing SCBs with upgraded ones. SCB 0, 1, and
2 are available for the MX960. SCB 0 is associated with RE0, SCB1 is associated with
RE1, and ; SCB 2 is the spare SCB. The SCB order for MX960 is SCB2, SCB1 (backup
Routing Engine slot), and SCB0 (Master Routing Engine slot).
NOTE: Do not add or remove any router hardware during the upgrade procedure.
Upgrading the First SCB
To upgrade the first SCB—that is—SCB2:
1.
Take the fabric plane offline by issuing the request chassis fabric plane 4 offline command.
2.
Verify that the fabric plane is offline by issuing the show chassis fabric summary command.
user@host> show chassis fabric summary
Plane State Uptime
4 Offline
5 Online 1 hour, 15 minutes, 35 seconds
Verify that the State of Plane 4 is Offline.
3.
Take the next fabric plane offline by issuing the request chassis fabric plane 5 offline command, and then verify that the fabric plane is offline by issuing the command given in Step 2.
4.
Take the SCB in slot 2 offline by issuing the request chassis cb offline slot 2 command.
5.
Verify that the control board is offline by issuing the show chassis environment cb 2 command: user@host> show chassis environment cb 2
CB 2 status:
State Offline
Power 1 Disabled
Power 2 Disabled
6.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
7.
Remove and replace SCB2 on the router with the SCBE.
430 Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
8.
Verify that the installation is successful and the SCB is online by issuing the show chassis environment cb 2 command: user@host> show chassis environment cb 2
CB 2 status
State Online
Temperature 30 degrees C / 86 degrees F
Other details, such as, power are also displayed along with the state.
9.
Verify that the fabric planes come online correctly by issuing the show chassis fabric summary command: user@host> show chassis fabric summary
Plane State Uptime
4 Online 2 minutes, 25 seconds
5 Online 2 minutes, 15 seconds
10.
Verify the alarms by issuing the show chassis alarms command: user@host> show chassis alarms
Alarm Time Class Description
2011-06-01 13:26:56 EDT Major CB fabrics are of mixed types
2011-06-01 12:10:41 EDT Major Require a fan tray upgrade
Because only one SCB has been upgraded, the alarm indicates that the SCBs are of mixed type. This alarm is cleared after all the control boards are upgraded.
Upgrading the SCB in the Backup Routing Engine
To upgrade the SCB in the backup Routing Engine:
1.
Power down the backup Routing Engine from the master Routing Engine by issuing the request system power-off other-routing-engine command.
2.
Ensure that the Routing Engine is powered down by issuing the show chassis routing-engine 1 command. The slot of the Routing Engine may be 0 or 1, and is shown as 1 in this example: user@host> show chassis routing-engine 1
Routing Engine Status:
Slot 1:
Current State Present
Verify that the Current State is Present, which indicates that the Routing Engine is offline.
3.
Take the first fabric plane of the backup Routing Engine offline by issuing the request chassis fabric plane 3 offline command.
4.
Verify that the fabric plane is offline by issuing the show chassis fabric summary command.
Copyright © 2017, Juniper Networks, Inc.
431
MX960 3D Universal Edge Router Hardware Guide user@host> show chassis fabric summary
Plane State Uptime
2 Online 3 minutes, 45 seconds
3 Offline
Check if the State of Plane 3 is Offline.
5.
Take the next fabric plane offline by issuing the request chassis fabric plane 2 offline command and verify that the fabric plane is offline by issuing the command in Step
4.
6.
Take the SCB in slot 1 offline by issuing the request chassis cb offline slot 1 command.
7.
Verify that the SCB is offline by issuing the show chassis environment cb 1 command: user@host> show chassis environment cb 1
CB 1 status:
State Offline
Power 1 Disabled
Power 2 Disabled
8.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
9.
Remove and replace the offline SCB on the router with the SCBE.
10.
Verify that the installation is successful and the SCB is online by issuing the show chassis environment cb 1 command: user@host> show chassis environment cb 1
CB 1 status
State Online
Temperature 30 degrees C / 86 degrees F
Other details, such as power, are also displayed along with the state.
11.
Verify that the fabric planes 2 and 3 come online correctly by issuing the show chassis fabric summary command: user@host> show chassis fabric summary
Plane State Uptime
2 Online 2 minutes, 5 seconds
3 Online 1 minutes, 55 seconds
12.
Verify that the backup routing engine is back online by issuing the show chassis routing-engine 1 command: user@host> show chassis routing-engine 1
Routing Engine Status:
Slot 1:
Current State Backup
432 Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
Upgrading the SCB in the Master Routing Engine
To upgrade the SCB in the master Routing Engine slot:
1.
Ensure a Graceful RE Switchover (GRES) to gracefully switch between the master and backup Routing Engines, so that the backup RE becomes the master RE, by issuing the request chassis routing-engine master switch command.
2.
Log in to the new master Routing Engine after the switchover.
3.
Switch the configuration mode to ensure that you are still in configure exclusive mode by issuing the exit command and then the configure exclusive command, from the old master Routing Engine.
4.
Log in to the current master Routing Engine again and issue the configure exclusive command.
5.
Power down the backup Routing Engine from the master Routing Engine by issuing the request system power-off other-routing-engine command.
6.
Ensure that the Routing Engine is powered down by issuing the show chassis routing-engine 0 command. The slot of the Routing Engine may be 0 or 1, and is shown as 1 in this example: user@host> show chassis routing-engine 1
Routing Engine Status:
Slot 0:
Current State Present
Verify that the Current State is Present, which indicates that the Routing Engine is offline or powered down.
7.
Take the first fabric plane of the backup Routing Engine offline by issuing the request chassis fabric plane offline 1 command.
8.
Verify that the fabric plane is offline by issuing the show chassis fabric summary command.
user@host> show chassis fabric summary
Plane State Uptime
1 Offline
2 Online 3 minutes, 25 seconds
Verify that the State of Plane 1 is Offline.
9.
Take the next fabric plane offline by issuing the request chassis fabric plane offline 0 command and verify that the fabric plane is offline by issuing the command given in
Step 2.
Copyright © 2017, Juniper Networks, Inc.
433
MX960 3D Universal Edge Router Hardware Guide
434
10.
Take the SCB in slot 0 offline by issuing the request chassis cb offline slot 0 command.
11.
Verify that the control board is offline by issuing the show chassis environment cb 0 command: user@host> show chassis environment cb 0
CB 0 status:
State Offline
Power 1 Disabled
Power 2 Disabled
12.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
13.
Remove and replace the offline SCB on the router with the SCBE.
14.
Verify that the installation is successful and the SCB is online by issuing the show chassis environment cb 0 command: user@host> show chassis environment cb 0
CB 0 status
State Online
Temperature 30 degrees C / 86 degrees F
Other details, such as power, are also displayed, along with the state.
15.
Verify that the fabric planes 0 and 1 come online correctly by issuing the show chassis fabric summary command: user@host> show chassis fabric summary
Plane State Uptime
0 Online 2 minutes, 9 seconds
1 Online 2 minutes, 2 seconds
16.
Verify that the backup Routing Engine is back online by issuing the show chassis routing-engine 0 command: user@host> show chassis routing-engine 0
Routing Engine Status:
Slot 0:
Current State Backup
17.
Verify the alarms by issuing the show chassis alarms command: user@host> show chassis alarms
Alarm Time Class Description
2011-06-01 13:26:56 EDT Major CB fabric links require upgrade/training
2011-06-01 12:10:41 EDT Major Require a fan tray upgrade
The “major” alarm has now changed from “CB fabrics are of mixed types” to “CB fabric links require upgrade/training.” This is because there is a switch control board that requires training to change links from 3G speed to 6G speed of the SCBE. This alarm is displayed until the 3G to 6G link transition is completed.
Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
Completing the SCB Upgrade
To complete the procedure after upgrading the SCBs:
1.
Verify that any Modular Port Concentrator (MPC) is running at 3G instead of 6G by issuing the request chassis fabric upgrade-bandwidth info command: user@host> request chassis fabric upgrade-bandwidth info
Slot State
0 Upgrade not supported
1 Upgraded
2 Empty
3 Empty
4 Empty
5 Empty
6 Empty
7 Empty
The results indicate that slot 0 does not support the upgrade and slot 1 needs upgrade.
NOTE: The SCBE line card supports only DPC, MS-DPC, MPC1, MPC2, and
MPC3 line cards for the upgrade-bandwidth command. If line cards that do not support the upgrade-bandwidth command option are present in the chassis during the SCB to SCBE upgrade, the request chassis fabric upgrade-bandwidth commands will return Upgrade not supported for the slot(s) that contain the unsupported line card(s).
2.
Upgrade the bandwidth of all MPCs by issuing the request chassis fabric upgrade-bandwidth fpc all command. If you want to control the MPC line card upgrade, go to Step 3.
CAUTION: Use this command only if you are not concerned with the slot upgrade order or if only one old MPC is present in the chassis. Running this command may result in a loss of traffic across that MPC. Using this method may increase that loss, as it does not consider any redundancy or graceful switchover strategies that you may have configured on the system.
3.
Upgrade the MPC in slot 1 by running the request chassis fabric upgrade-bandwidth fpc slot 1 command.
4.
Verify that the MPC is upgraded by issuing the request chassis fabric upgrade-bandwidth info command: user@host> request chassis fabric upgrade-bandwidth info
Slot State
0 Upgrade not supported
1 Upgraded
2 Empty
Copyright © 2017, Juniper Networks, Inc.
435
MX960 3D Universal Edge Router Hardware Guide
436
5.
Verify the state of fabric planes for all MPCs by issuing the show chassis fabric summary command.
user@host> show chassis fabric summary
Plane State Uptime
0 Spare 21 seconds
1 Spare 12 seconds
2 Online 12 minutes
3 Online 12 minutes
4 Online 30 minutes
5 Online 30 minutes
6.
Verify the state of MPCs by issuing the show chassis fabric fpcs command.
user@host> show chassis fabric fpcs
FPC 1
PFE #0
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #1
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #2
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #3
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
Fabric plane details of all MPCs are similarly displayed.
7.
Verify if any output of the show chassis fabric summary command shows fabric planes in 'check' state, as it indicates that the fabric plane has an error. You can try to recover the fabric plane to normal operation by issuing the request chassis fabric plane <#> offline command, followed by the request chassis fabric plane <#> online command, where <#> equals the fabric plane in error.
NOTE: After you issue the request chassis fabric plane <#> offline and request chassis fabric plane <#> online commands, issue the show chassis fabric summary command to verify that the fabric plane errors are rectified and to verify the current state of the fabric planes.
Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
8.
Verify that the major alarms are displayed by issuing the show chassis alarms command: user@host> show chassis alarms
Alarm Time Class Description
2011-06-01 13:37:43 EDT Minor Require a fan tray upgrade
2011-06-01 13:37:26 EDT Minor Backup RE Active
The major alarms are not displayed anymore, and the upgrade is successfully completed.
9.
Disable the upgrade configuration by issuing the set chassis state cb-upgrade off command and then the commit command.
10.
You can delete that command by issuing the delete chassis state cb-upgrade command and then the commit command.
11.
Verify the SCBs before you finish by issuing the show chassis hardware command: user@host> show chassis hardware
Item Version Part Number Serial Number Description
CB0 REV 02 750-031391 YE8505 Enhanced MX SCB
CB1 REV 07 710-031391 YL6769 Enhanced MX SCB
CB2 REV 07 710-031391 YE8492 Enhanced MX SCB
You can see that the MX960 now has MX SCBEs.
Related
Documentation
•
Removing an MX960 SCB on page 410
•
Installing an MX960 SCB on page 302
Replacing an SFP or XFP Transceiver on an MX960 DPC, MPC, MIC, or PIC
Small form-factor pluggable (SFPs) and XFPs are optical transceivers that are installed in a DPC or PIC. SFPs and XFPs are hot-insertable and hot-removable.
1.
Removing an SFP or XFP Transceiver from an MX960 DPC, MPC, MIC, or PIC on page 437
2.
Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC on page 439
Removing an SFP or XFP Transceiver from an MX960 DPC, MPC, MIC, or PIC
Removing an SFP or XFP does not interrupt DPC, MPC, MIC, or PIC functioning, but the removed SFP or XFP no longer receives or transmits data.
Copyright © 2017, Juniper Networks, Inc.
437
MX960 3D Universal Edge Router Hardware Guide
To remove an SFP or XFP transceiver (see
1.
Have ready a replacement transceiver or a transceiver slot plug, an antistatic mat, and a rubber safety cap for the transceiver.
2.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
3.
Label the cables connected to the transceiver so that you can reconnect them correctly later.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
4.
Remove the cable connector from the transceiver.
5.
Pull the ejector handle out from the transceiver to unlock the transceiver.
CAUTION: Make sure that you open the ejector handle completely until you hear it click. This prevents damage to the transceiver.
Use needlenose pliers to pull the ejector handle out from the transceiver.
6.
Grasp the transceiver ejector handle, and pull the transceiver approximately 0.5 in. (1.3
cm) out of the DPC, MPC, MIC, or PIC.
7.
Using your fingers, grasp the body of the transceiver, and pull it the rest of the way out of the DPC, MPC, MIC, or PIC.
Figure 171: Removing SFPs or XFPs
438 Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Replacing Switch Fabric Components
8.
Place a rubber safety cap over the transceiver.
9.
Place the removed transceiver on an antistatic mat or in an electrostatic bag.
CAUTION: After removing a transceiver from the chassis, wait at least 30 seconds before reinserting it or inserting a transceiver into a different slot.
Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC
To install an SFP or XFP:
1.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
ESD points on the chassis.
2.
Take each transceiver to be installed out of its electrostatic bag, and identify the slot on the component where it will be installed.
3.
Verify that each transceiver is covered by a rubber safety cap. If it is not, cover the transceiver with a safety cap.
4.
Carefully align the transceiver with the slots in the component. The connectors should face the component.
5.
Slide the transceiver until the connector is seated in the component slot. If you are unable to fully insert the transceiver, make sure the connector is facing the right way.
6.
Close the ejector handle of the transceiver.
7.
Remove the rubber safety cap from the transceiver and the end of the cable. Insert the cable into the transceiver.
WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
8.
Verify that the status LEDs on the component faceplate indicate that the SFP or XFP is functioning correctly. For more information about the component LEDs, see the MX
Series Interface Module Reference .
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX960 Router
•
Replacing an MX960 PIC on page 382
Copyright © 2017, Juniper Networks, Inc.
439
MX960 3D Universal Edge Router Hardware Guide
•
Replacing an MX960 DPC on page 355
440 Copyright © 2017, Juniper Networks, Inc.
PART 5
Maintaining the Chassis and Components
•
Routine Maintenance Procedures on page 443
•
Maintaining Components on page 445
•
Converting to a Different Type of Power Supply on page 473
Copyright © 2017, Juniper Networks, Inc.
441
MX960 3D Universal Edge Router Hardware Guide
442 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 28
Routine Maintenance Procedures
•
Routine Maintenance Procedures for the MX960 Router on page 443
Routine Maintenance Procedures for the MX960 Router
Purpose For optimum router performance, perform preventive maintenance procedures.
Action • Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Make sure that airflow is unobstructed around the router and into the air intake vents.
• Check the status-reporting devices on the craft interface—System alarms and LEDs.
• Inspect the air filter at the left rear of the router, replacing it every 6 months for optimum cooling system performance. Do not run the router for more than a few minutes without the air filter in place.
Related
Documentation
•
Tools and Parts Required to Maintain the MX960 Router on page 445
•
Maintaining the MX960 Air Filter on page 446
•
Maintaining the MX960 Fan Trays on page 446
Copyright © 2017, Juniper Networks, Inc.
443
MX960 3D Universal Edge Router Hardware Guide
444 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 29
Maintaining Components
•
Tools and Parts Required to Maintain the MX960 Router on page 445
•
Maintaining the MX960 Air Filter on page 446
•
Maintaining the MX960 Fan Trays on page 446
•
Maintaining the MX960 Host Subsystem on page 448
•
Maintaining MX960 DPCs on page 450
•
Holding an MX960 DPC on page 452
•
Storing an MX960 DPC on page 454
•
Maintaining MX960 FPCs on page 455
•
Holding an MX960 FPC on page 457
•
Storing an MX960 FPC on page 461
•
Maintaining MX960 MICs on page 462
•
Maintaining MX960 MPCs on page 463
•
Maintaining MX960 PICs on page 466
•
Maintaining Cables That Connect to MX960 DPCs, MPCs, MICs, or PICs on page 466
•
Maintaining the MX960 Power Supplies on page 468
•
Verifying the Version of the MX960 Cable Manager on page 469
Tools and Parts Required to Maintain the MX960 Router
To maintain hardware components, you need the following tools and parts:
• ESD grounding wrist strap
• Flat-blade (–) screwdriver
• Phillips (+) screwdriver, number 1
• Phillips (+) screwdriver, number 2
Related
Documentation
•
Routine Maintenance Procedures for the MX960 Router on page 443
•
Maintaining the MX960 Host Subsystem on page 448
•
Maintaining the MX960 Power Supplies on page 468
Copyright © 2017, Juniper Networks, Inc.
445
MX960 3D Universal Edge Router Hardware Guide
Maintaining the MX960 Air Filter
Purpose For optimum cooling, verify the condition of the air filters.
Action • Regularly inspect the air filter. A dirty air filter restricts airflow in the unit, producing a negative effect on the ventilation of the chassis. The filter degrades over time. You must replace the filter every 6 months.
CAUTION: Always keep the air filter in place while the router is operating.
Because the fans are very powerful, they could pull small bits of wire or other materials into the router through the unfiltered air intake. This could damage the router components.
• The shelf life of polyurethane filter varies from two years to five years depending on the storage conditions. Store in a cool, dry, and dark environment. Wrap the media in plastic and store in an environment with relative humidity between 40%- 80% and temperature between 40°F (4° C) to 90°F (32° C). Note that if the material flakes, or becomes brittle when rubbed or deformed, it is no longer usable.
Related
Documentation
•
Tools and Parts Required to Maintain the MX960 Router on page 445
•
Replacing the MX960 Air Filter on page 325
•
Installing the MX960 Air Filter on page 266
Maintaining the MX960 Fan Trays
Purpose For optimum cooling, verify the condition of the fans.
Action • Monitor the status of the fans. A fan tray contains multiple fans that work in unison to cool the router components. If one fan fails, the host subsystem adjusts the speed of the remaining fans to maintain proper cooling. A red alarm is triggered when a fan fails, and a yellow alarm and red alarm is triggered when a fan tray is removed.
• To display the status of the cooling system, issue the show chassis environment command. The output is similar to the following: user@host> show chassis environment
Class Item Status Measurement
Temp PEM 0 OK 40 degrees C / 104 degrees F
PEM 1 Absent
PEM 2 Absent
PEM 3 OK 40 degrees C / 104 degrees F
Routing Engine 0 OK 39 degrees C / 102 degrees F
Routing Engine 1 OK 42 degrees C / 107 degrees F
CB 0 Intake OK 26 degrees C / 78 degrees F
446 Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
CB 0 Exhaust A OK 27 degrees C / 80 degrees F
CB 0 Exhaust B OK 27 degrees C / 80 degrees F
CB 0 ACBC OK 26 degrees C / 78 degrees F
CB 0 SF A OK 37 degrees C / 98 degrees F
CB 0 SF B OK 35 degrees C / 95 degrees F
CB 1 Intake OK 27 degrees C / 80 degrees F
CB 1 Exhaust A OK 30 degrees C / 86 degrees F
CB 1 Exhaust B OK 28 degrees C / 82 degrees F
CB 1 ACBC OK 27 degrees C / 80 degrees F
CB 1 SF A OK 36 degrees C / 96 degrees F
CB 1 SF B OK 36 degrees C / 96 degrees F
CB 2 Intake Absent
CB 2 Exhaust A Absent
CB 2 Exhaust B Absent
CB 2 ACBC Absent
CB 2 SF A Absent
CB 2 SF B Absent
FPC 2 Intake OK 22 degrees C / 71 degrees F
FPC 2 Exhaust A OK 27 degrees C / 80 degrees F
FPC 2 Exhaust B OK 33 degrees C / 91 degrees F
FPC 2 I3 0 TSensor OK 33 degrees C / 91 degrees F
FPC 2 I3 0 Chip OK 35 degrees C / 95 degrees F
FPC 2 I3 1 TSensor OK 33 degrees C / 91 degrees F
FPC 2 I3 1 Chip OK 33 degrees C / 91 degrees F
FPC 2 I3 2 TSensor OK 33 degrees C / 91 degrees F
FPC 2 I3 2 Chip OK 30 degrees C / 86 degrees F
FPC 2 I3 3 TSensor OK 30 degrees C / 86 degrees F
FPC 2 I3 3 Chip OK 30 degrees C / 86 degrees F
FPC 2 IA 0 TSensor OK 33 degrees C / 91 degrees F
FPC 2 IA 0 Chip OK 36 degrees C / 96 degrees F
FPC 2 IA 1 TSensor OK 30 degrees C / 86 degrees F
FPC 2 IA 1 Chip OK 35 degrees C / 95 degrees F
FPC 4 Intake OK 22 degrees C / 71 degrees F
FPC 4 Exhaust A OK 28 degrees C / 82 degrees F
FPC 4 Exhaust B OK 31 degrees C / 87 degrees F
FPC 4 I3 0 TSensor OK 31 degrees C / 87 degrees F
FPC 4 I3 0 Chip OK 34 degrees C / 93 degrees F
FPC 4 I3 1 TSensor OK 31 degrees C / 87 degrees F
FPC 4 I3 1 Chip OK 33 degrees C / 91 degrees F
FPC 4 I3 2 TSensor OK 31 degrees C / 87 degrees F
FPC 4 I3 2 Chip OK 29 degrees C / 84 degrees F
FPC 4 I3 3 TSensor OK 29 degrees C / 84 degrees F
FPC 4 I3 3 Chip OK 29 degrees C / 84 degrees F
FPC 4 IA 0 TSensor OK 35 degrees C / 95 degrees F
FPC 4 IA 0 Chip OK 37 degrees C / 98 degrees F
FPC 4 IA 1 TSensor OK 31 degrees C / 87 degrees F
FPC 4 IA 1 Chip OK 35 degrees C / 95 degrees F
FPC 7 Intake OK 20 degrees C / 68 degrees F
FPC 7 Exhaust A OK 21 degrees C / 69 degrees F
FPC 7 Exhaust B OK 21 degrees C / 69 degrees F
FPC 7 I3 0 TSensor OK 31 degrees C / 87 degrees F
FPC 7 I3 0 Chip OK 36 degrees C / 96 degrees F
FPC 7 I3 1 TSensor OK 32 degrees C / 89 degrees F
FPC 7 I3 1 Chip OK 35 degrees C / 95 degrees F
FPC 7 I3 2 TSensor OK 32 degrees C / 89 degrees F
FPC 7 I3 2 Chip OK 30 degrees C / 86 degrees F
FPC 7 I3 3 TSensor OK 30 degrees C / 86 degrees F
FPC 7 I3 3 Chip OK 31 degrees C / 87 degrees F
FPC 7 IA 0 TSensor OK 34 degrees C / 93 degrees F
FPC 7 IA 0 Chip OK 37 degrees C / 98 degrees F
FPC 7 IA 1 TSensor OK 31 degrees C / 87 degrees F
Copyright © 2017, Juniper Networks, Inc.
447
MX960 3D Universal Edge Router Hardware Guide
FPC 7 IA 1 Chip OK 35 degrees C / 95 degrees F
Fans Top Fan Tray Temp OK 27 degrees C / 80 degrees F
Top Tray Fan 1 OK Spinning at high speed
Top Tray Fan 2 OK Spinning at high speed
Top Tray Fan 3 OK Spinning at high speed
Top Tray Fan 4 OK Spinning at high speed
Top Tray Fan 5 OK Spinning at high speed
Top Tray Fan 6 OK Spinning at high speed
Bottom Fan Tray Temp OK 28 degrees C / 82 degrees F
Bottom Tray Fan 1 OK Spinning at high speed
Bottom Tray Fan 2 OK Spinning at high speed
Bottom Tray Fan 3 OK Spinning at high speed
Bottom Tray Fan 4 OK Spinning at high speed
Bottom Tray Fan 5 OK Spinning at high speed
Bottom Tray Fan 6 OK Spinning at high speed
NOTE: The fan numbers are stamped into the fan tray sheet metal next to each fan.
Related
Documentation
•
Tools and Parts Required to Maintain the MX960 Router on page 445
•
Replacing an MX960 Fan Tray on page 327
Maintaining the MX960 Host Subsystem
Purpose For optimum router performance, verify the condition of the host subsystem. The host subsystem includes an SCB and a Routing Engine installed into a slot in the SCB.
Action On a regular basis:
• Check the LEDs on the craft interface to view information about the status of the
Routing Engines.
• Check the LEDs on the SCB faceplate (see Table 9 in
“MX960 SCB Description” on page 107
).
• Check the LEDs on the Routing Engine faceplate (see Table 10 in
Engine Description” on page 29 ).
• To check the status of the Routing Engines, issue the show chassis routing-engine command. The output is similar to the following: user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 39 degrees C / 102 degrees F
CPU temperature 47 degrees C / 116 degrees F
DRAM 3584 MB
448 Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
Memory utilization 10 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 6 percent
Interrupt 0 percent
Idle 94 percent
Model RE-S-2000
Serial ID 1000639065
Start time 2006-11-07 11:42:58 PST
Uptime 53 minutes, 35 seconds
Load averages: 1 minute 5 minute 15 minute
0.06 0.07 0.02
Routing Engine status:
Slot 1:
Current state Backup
Election priority Backup (default)
Temperature 42 degrees C / 107 degrees F
CPU temperature 50 degrees C / 122 degrees F
DRAM 3584 MB
Memory utilization 9 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percent
Model RE-S-2000
Serial ID 1000664335
Start time 2006-11-02 18:35:01 PST
Uptime 4 days, 18 hours, 1 minute, 28 seconds
• To check the status of the SCBs, issue the show chassis environment cb command.
The output is similar to the following: user@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 26 degrees C / 78 degrees F
Power 1
1.2 V 1202 mV
1.5 V 1508 mV
1.8 V 1830 mV
2.5 V 5053 mV
3.3 V 6593 mV
5.0 V 5111 mV
12.0 V 12181 mV
1.25 V 1263 mV
3.3 V SM3 6593 mV
5 V RE 5078 mV
12 V RE 12007 mV
Power 2
11.3 V bias PEM 11253 mV
4.6 V bias MidPlane 4827 mV
11.3 V bias FPD 11408 mV
11.3 V bias POE 0 11446 mV
11.3 V bias POE 1 11408 mV
Bus Revision 6
Copyright © 2017, Juniper Networks, Inc.
449
MX960 3D Universal Edge Router Hardware Guide
FPGA Revision 0
CB 1 status:
State Online Standby
Temperature 27 degrees C / 80 degrees F
Power 1
1.2 V 1214 mV
1.5 V 1517 mV
1.8 V 1814 mV
2.5 V 2507 mV
3.3 V 3312 mV
5.0 V 5136 mV
12.0 V 12142 mV
1.25 V 1256 mV
3.3 V SM3 3306 mV
5 V RE 5085 mV
12 V RE 11949 mV
Power 2
11.3 V bias PEM 11369 mV
4.6 V bias MidPlane 4814 mV
11.3 V bias FPD 11427 mV
11.3 V bias POE 0 11350 mV
11.3 V bias POE 1 11330 mV
Bus Revision 39
FPGA Revision 1
To check the status of a specific SCB, issue the show chassis environment cb command and include the slot number of the SCB—for example, show chassis environment cb 0 .
For more information about using the CLI, see the Junos OS manuals.
Related
Documentation
•
MX960 Craft Interface Overview on page 15
•
MX960 Host Subsystem Description on page 27
• Taking an MX960 Host Subsystem Offline
• Effect of Taking the MX960 Host Subsystem Offline
Maintaining MX960 DPCs
Purpose The router can have up to 12 Dense Port Concentrators (DPCs) mounted vertically in the
DPC card cage at the front of the chassis. For optimum router performance, verify the condition of the DPCs.
Action On a regular basis:
• Check the LEDs on the craft interface directly above each DPC slot. The green LED labeled OK lights steadily when a DPC is functioning normally.
• Check the OK/FAIL LED on the DPC. For more information, see MX Series Interface
Module Reference . If the DPC detects a failure, the DPC sends an alarm message to the
Routing Engine.
450 Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
• Check the status of installed DPCs by issuing the CLI show chassis fpc command to check the status of installed DPCs. As shown in the sample output, the value Online in the column labeled State indicates that the DPC is functioning normally: user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Empty
1 Empty
2 Online 22 40 0 1024 15 57
3 Empty
4 Online 22 24 0 1024 15 57
5 Empty
6 Empty
7 Offline ---Offlined by cli command---
8 Empty
9 Empty
10 Empty
11 Empty
For more detailed output, add the detail option. The following example does not specify a slot number, which is optional: user@host> show chassis fpc detail
Slot 2 information:
State Online
Temperature 22 degrees C / 71 degrees F
Total CPU DRAM 1024 MB
Total SRAM 256 MB
Total SDRAM 0 MB
Start time 2006-11-03 07:35:40 PST
Uptime 2 hours, 27 minutes, 1 second
Slot 4 information:
State Online
Temperature 22 degrees C / 71 degrees F
Total CPU DRAM 1024 MB
Total SRAM 256 MB
Total SDRAM 0 MB
Start time 2006-11-03 07:35:48 PST
Uptime 2 hours, 26 minutes, 53 seconds
Slot 7 information:
State Online
Temperature 24 degrees C / 75 degrees F
Total CPU DRAM 1024 MB
Total SRAM 256 MB
Total SDRAM 0 MB
Start time 2006-11-03 07:35:53 PST
Uptime 2 hours, 26 minutes, 48 seconds
• Issue the CLI show chassis fpc pic-status command. The DPC slots are numbered from
0 through 5 , 2/6 , 7 through 11 , left to right: user@host> show chassis fpc pic-status
Slot 2 Online MX960 40GE DPC
PIC 0 Online 10x 1GE
PIC 1 Online 10x 1GE
PIC 2 Online 10x 1GE
PIC 3 Online 10x 1GE
Slot 4 Online MX960 4 XGE DPC
Copyright © 2017, Juniper Networks, Inc.
451
MX960 3D Universal Edge Router Hardware Guide
PIC 0 Online 1x 10GE(LAN/WAN)
PIC 1 Online 1x 10GE(LAN/WAN)
PIC 2 Online 1x 10GE(LAN/WAN)
PIC 3 Online 1x 10GE(LAN/WAN)
Slot 7 Offline MX960 4 XGE DPC
For further description of the output from the command, see the CLI Explorer .
Related
Documentation
•
MX960 Chassis Description on page 9
•
MX960 Dense Port Concentrator Description on page 53
•
MX960 DPC and MPC LEDs on the Craft Interface on page 18
•
Troubleshooting the MX960 DPCs on page 490
•
Replacing an MX960 DPC on page 355
Holding an MX960 DPC
When carrying a DPC, you can hold it either vertically or horizontally.
NOTE: A DPC weighs 14.5 lb (6.6 kg). Be prepared to accept the full weight of the DPC as you lift it.
To hold a DPC vertically:
1.
Orient the DPC so that the faceplate faces you. To verify orientation, confirm that the text on the DPC is right-side up and the electromagnetic interference (EMI) strip is on the right-hand side.
2.
Place one hand around the DPC faceplate about a quarter of the way down from the top edge. To avoid deforming the EMI shielding strip, do not press hard on it.
3.
Place your other hand at the bottom edge of the DPC.
If the DPC is horizontal before you grasp it, place your left hand around the faceplate and your right hand along the bottom edge.
To hold a DPC horizontally:
1.
Orient the DPC so that the faceplate faces you.
2.
Grasp the top edge with your left hand and the bottom edge with your right hand.
You can rest the faceplate of the DPC against your body as you carry it.
As you carry the DPC, do not bump it against anything. DPC components are fragile.
452 Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
Never hold or grasp the DPC anywhere except places that this document indicates. In particular, never grasp the connector edge, especially at the power connector in the corner where the connector and bottom edges meet. See
.
Figure 172: Do Not Grasp the Connector Edge
Never carry the DPC by the faceplate with only one hand.
Do not rest any edge of a DPC directly against a hard surface (see
Do not stack DPCs.
Copyright © 2017, Juniper Networks, Inc.
453
MX960 3D Universal Edge Router Hardware Guide
Figure 173: Do Not Rest the DPC on an Edge
If you must rest the DPC temporarily on an edge while changing its orientation between vertical and horizontal, use your hand as a cushion between the edge and the surface.
Related
Documentation
• MX960 DPC Terminology
•
Storing an MX960 DPC on page 454
•
Troubleshooting the MX960 DPCs on page 490
•
Replacing an MX960 DPC on page 355
Storing an MX960 DPC
You must store a DPC as follows:
• In the router
• In the container in which a spare DPC is shipped
• Horizontally and sheet metal side down
When you store a DPC on a horizontal surface or in the shipping container, always place it inside an antistatic bag. Because the DPC is heavy, and because antistatic bags are fragile, inserting the DPC into the bag is easier with two people. To do this, one person holds the DPC in the horizontal position with the faceplate facing the body, and the other person slides the opening of the bag over the DPC connector edge.
454 Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
If you must insert the DPC into a bag by yourself, first lay the DPC horizontally on a flat, stable surface, sheet metal side down. Orient the DPC with the faceplate facing you.
Carefully insert the DPC connector edge into the opening of the bag, and pull the bag toward you to cover the DPC.
Never stack a DPC under or on top of any other component.
Related
Documentation
• MX960 DPC Terminology
•
Holding an MX960 DPC on page 452
•
Maintaining MX960 DPCs on page 450
•
Replacing an MX960 DPC on page 355
•
Troubleshooting the MX960 DPCs on page 490
Maintaining MX960 FPCs
Purpose The router can have one Flexible PIC Concentrator (FPC) installed vertically in two DPC slots at the front of the chassis. For optimum router performance, verify the condition of the FPC.
Action On a regular basis:
• Check the LEDs on the craft interface directly above the FPC. The green LED labeled
OK lights steadily when an FPC is functioning normally.
• Check the OK/FAIL LED on the FPC. If the FPC detects a failure, the FPC sends an alarm message to the Routing Engine.
• Issue the CLI show chassis fpc command to check the status of the installed FPC. As shown in the sample output, the value Online in the column labeled State indicates that the FPC is functioning normally: user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 24 3 0 1024 13 21
1 Empty
2 Online 41 9 0 1024 15 57
3 Online 43 5 0 1024 16 57
4 Online 43 11 0 1024 16 57
5 Online 41 9 0 1024 15 57
6 Online 43 5 0 1024 16 57
7 Empty
8 Empty
9 Empty
10 Online 24 3 0 1024 13 21
11 Empty
For more detailed output, add the detail option. The following example does not specify a slot number, which is optional:
Copyright © 2017, Juniper Networks, Inc.
455
MX960 3D Universal Edge Router Hardware Guide
456 user@host> show chassis fpc detail
Slot 0 information:
State Online
Temperature 24 degrees C / 75 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 128 MB
Total DDR DRAM 2048 MB
Start time: 2008-12-11 16:53:24 PST
Uptime: 15 hours, 2 minutes, 47 seconds
Slot 2 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Slot 3 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Slot 4 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Slot 5 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:22 PST
Uptime: 15 hours, 2 minutes, 49 seconds
Slot 6 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Slot 10 information:
State Online
Temperature 24 degrees C / 75 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 128 MB
Total DDR DRAM 2048 MB
Start time: 2008-12-11 16:53:24 PST
Uptime: 15 hours, 2 minutes, 47 seconds
• Issue the CLI show chassis fpc pic-status command. The following example shows an
FPC installed in DPC slots 1 and 2 :
Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components user@host> show chassis fpc pic-status
Slot 0 Online DPC 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
Slot 1 Online MX FPC Type 3
PIC 0 Online 1x OC-192 SONET
PIC 1 Online 1x OC-192 SONET
NOTE: An FPC takes up two DPC slots when installed on an MX Series router. The slot number corresponds to the lowest numbered DPC slot.
For further description of the output from the command, see the CLI Explorer .
Related
Documentation
•
MX960 Flexible PIC Concentrator (FPC) LEDs on page 65
•
Troubleshooting the MX960 FPCs on page 492
•
Replacing an MX960 FPC on page 361
•
Holding an MX960 FPC on page 457
•
Storing an MX960 FPC on page 461
Holding an MX960 FPC
CAUTION: Many components on the FPC are fragile. Failure to handle FPCs as specified in this document can cause irreparable damage.
NOTE: An FPC configured with PICs installed can weigh as much as
18 lb (8.2 kg). Be prepared to accept the full weight of the FPC as you lift it.
CAUTION: To prevent damage when handling or carrying FPCs:
• As you carry the FPC, do not bump it against anything. FPC components are fragile.
• Do not grasp the FPC anywhere except places that this document indicates.
In particular, never grasp the connector edge, especially at the power connector in the corner where the connector and bottom edges meet (see
).
Copyright © 2017, Juniper Networks, Inc.
457
MX960 3D Universal Edge Router Hardware Guide
Figure 174: Do Not Grasp the Connector Edge
• Do not carry the FPC by the faceplate with only one hand (see
).
458 Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
Figure 175: Do Not Carry an FPC with Only One Hand
Copyright © 2017, Juniper Networks, Inc.
• Do not rest any edge of an FPC directly against a hard surface (see
Figure 176 on page 460 ). If you must rest the FPC temporarily on an edge
while changing its orientation between vertical and horizontal, use your hand as a cushion between the edge and the surface.
459
MX960 3D Universal Edge Router Hardware Guide
Figure 176: Do Not Rest the FPC on an Edge
You hold an FPC vertically when installing it into the chassis or an equipment rack. To hold an FPC vertically (see
):
1.
Orient the FPC so that the faceplate faces you.
2.
Place one hand around the FPC faceplate about a quarter of the way down from the top edge. To avoid deforming the electromagnetic interference (EMI) shielding strip, do not press hard on it.
3.
Place your other hand at the bottom edge of the FPC. If the FPC has heat sinks about midway between the faceplate and connector edge, place your other hand against the heat sinks.
460 Copyright © 2017, Juniper Networks, Inc.
Figure 177: Holding an FPC Vertically
Chapter 29: Maintaining Components
Related
Documentation
•
MX960 Flexible PIC Concentrator Description on page 62
• MX960 FPC Terminology
•
Storing an MX960 FPC on page 461
Storing an MX960 FPC
When not installed in the routing platforms, FPCs must be either stored in the container in which a spare FPC is shipped or stored horizontally with the component-side up on a flat, stable surface. When you store an FPC on a horizontal surface or in the shipping container, always place it inside an antistatic bag. Because the FPC is heavy and because antistatic bags are fragile, inserting the FPC into the bag is easier with two people. The storage guidelines are as follows:
• When storing an FPC with two people, one person holds the FPC in the horizontal position with the faceplate facing their body, the other person slides the opening of the bag over the FPC connector edge.
• When storing an FPC with one person, you must insert the FPC into a bag by yourself.
First lay the FPC horizontally on a flat, stable surface, component-side up. Orient the
FPC with the faceplate facing you. Carefully insert the FPC connector edge into the opening of the bag, and pull the bag toward you to cover the FPC.
Copyright © 2017, Juniper Networks, Inc.
461
MX960 3D Universal Edge Router Hardware Guide
CAUTION: To prevent damage when storing FPCs:
• Never lay an FPC component-side down.
Figure 178: Do Not Stack FPCs
• Never stack an FPC under or on top of any other component (see
).
Related
Documentation
•
MX960 Flexible PIC Concentrator Description on page 62
• MX960 FPC Terminology
•
Holding an MX960 FPC on page 457
Maintaining MX960 MICs
Purpose For optimum router performance, verify the condition of the Modular Interface Cards
(MICs).
Action On a regular basis:
• Check the LEDs on MIC faceplates. The meaning of the LED states differs for various
MICs. For more information, see the MX Series Interface Module Reference . If the MPC that houses the MIC detects a MIC failure, the MPC generates an alarm message to be sent to the Routing Engine.
• Issue the CLI show chassis fpc pic-status command. The MIC slots in an MPC are numbered PIC 0/1 and PIC 2/3 , top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online DPCE 4x 10GE R EQ
PIC 0 Online 1x 10GE(LAN/WAN) EQ
PIC 1 Online 1x 10GE(LAN/WAN) EQ
PIC 2 Online 1x 10GE(LAN/WAN) EQ
PIC 3 Online 1x 10GE(LAN/WAN) EQ
Slot 1 Online DPCE 40x 1GE R EQ
PIC 0 Online 10x 1GE(LAN) EQ
PIC 1 Online 10x 1GE(LAN) EQ
462 Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
PIC 2 Online 10x 1GE(LAN) EQ
PIC 3 Online 10x 1GE(LAN) EQ
Slot 2 Online MS-DPC
PIC 0 Online MS-DPC PIC
PIC 1 Online MS-DPC PIC
Slot 3 Online MPC Type 2 3D EQ
PIC 0 Online 1x 10GE XFP
PIC 1 Online 1x 10GE XFP
Slot 4 Online MPC 3D 16x 10GE
PIC 0 Online 4x 10GE(LAN) SFP+
PIC 1 Online 4x 10GE(LAN) SFP+
PIC 2 Online 4x 10GE(LAN) SFP+
PIC 3 Online 4x 10GE(LAN) SFP+
Slot 6 Online MX960 40GE DPC
PIC 0 Online 10x 1GE
PIC 1 Online 10x 1GE
PIC 2 Online 10x 1GE
PIC 3 Online 10x 1GE
Slot 10 Online MPC 3D 16x 10GE
PIC 0 Online 4x 10GE(LAN) SFP+
PIC 1 Online 4x 10GE(LAN) SFP+
PIC 2 Online 4x 10GE(LAN) SFP+
PIC 3 Online 4x 10GE(LAN) SFP+
For further description of the output from the command, see the CLI Explorer .
Related
Documentation
•
MX960 Modular Interface Card Description on page 82
•
MX960 Modular Interface Card (MIC) LEDs on page 82
•
Troubleshooting the MX960 MICs on page 495
•
Replacing an MX960 MIC on page 367
Maintaining MX960 MPCs
Purpose The router can have up to 12 Modular Port Concentrators (MPCs) mounted vertically in the card cage at the front of the chassis. For optimum router performance, verify the condition of the MPCs.
Action On a regular basis:
• Check the LEDs on the craft interface directly above each MPC slot. The green LED labeled OK lights steadily when an MPC is functioning normally.
• Check the OK/FAIL LED on the MPC. If the MPC detects a failure, the MPC sends an alarm message to the Routing Engine.
• Issue the CLI show chassis fpc command to check the status of installed MPCs. As shown in the sample output, the value Online in the column labeled State indicates that the MPC is functioning normally: user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
Copyright © 2017, Juniper Networks, Inc.
463
MX960 3D Universal Edge Router Hardware Guide
464
0 Online 36 3 0 2048 14 13
1 Online 40 5 0 2048 26 13
2 Online 41 6 0 1024 7 43
3 Online 43 5 0 1024 16 57
4 Online 24 3 0 1024 13 21
5 Empty
6 Online 43 5 0 1024 16 57
7 Empty
8 Empty
9 Empty
10 Online 24 3 0 1024 13 21
11 Empty
For more detailed output, add the detail option. The following example does not specify a slot number, which is optional: user@host> show chassis fpc detail
Slot 0 information:
State Online
Temperature 33 degrees C / 91 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2009-12-22 12:26:54 PST
Uptime: 6 days, 3 hours, 8 minutes, 51 seconds
Max Power Consumption 330 Watts
Slot 1 information:
State Online
Temperature 32 degrees C / 89 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2009-12-22 12:26:54 PST
Uptime: 6 days, 3 hours, 8 minutes, 51 seconds
Max Power Consumption 365 Watts
Slot 2 information:
State Online
Temperature 41 degrees C / 105 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 128 MB
Total DDR DRAM 2048 MB
Start time: 2009-12-22 12:26:46 PST
Uptime: 6 days, 3 hours, 8 minutes, 59 seconds
Max Power Consumption 265 Watts
Slot 3 information:
State Online
Temperature 36 degrees C / 96 degrees F
Total CPU DRAM 2048 MB
Total RLDRAM 806 MB
Total DDR DRAM 2632 MB
Start time: 2009-12-22 12:27:04 PST
Uptime: 6 days, 3 hours, 8 minutes, 41 seconds
Max Power Consumption 450 Watts
Slot 4 information:
State Online
Temperature 40 degrees C / 104 degrees F
Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
Total CPU DRAM 2048 MB
Total RLDRAM 1324 MB
Total DDR DRAM 5120 MB
Start time: 2009-12-22 12:27:02 PST
Uptime: 6 days, 3 hours, 8 minutes, 43 seconds
Max Power Consumption 440 Watts
Slot 6 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Max Power Consumption 365 Watts
Slot 10 information:
State Online
Temperature 24 degrees C / 75 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 128 MB
Total DDR DRAM 2048 MB
Start time: 2008-12-11 16:53:24 PST
Uptime: 15 hours, 2 minutes, 47 seconds
Max Power Consumption 440 Watts
• Issue the CLI show chassis fpc pic-status command. The MPC slots are numbered 0 through 5 , bottom to top: user@host> show chassis fpc pic-status
Slot 0 Online DPCE 4x 10GE R EQ
PIC 0 Online 1x 10GE(LAN/WAN) EQ
PIC 1 Online 1x 10GE(LAN/WAN) EQ
PIC 2 Online 1x 10GE(LAN/WAN) EQ
PIC 3 Online 1x 10GE(LAN/WAN) EQ
Slot 1 Online DPCE 40x 1GE R EQ
PIC 0 Online 10x 1GE(LAN) EQ
PIC 1 Online 10x 1GE(LAN) EQ
PIC 2 Online 10x 1GE(LAN) EQ
PIC 3 Online 10x 1GE(LAN) EQ
Slot 2 Online MS-DPC
PIC 0 Online MS-DPC PIC
PIC 1 Online MS-DPC PIC
Slot 3 Online MPC Type 2 3D EQ
PIC 0 Online 1x 10GE XFP
PIC 1 Online 1x 10GE XFP
Slot 4 Online MPC 3D 16x 10GE
PIC 0 Online 4x 10GE(LAN) SFP+
PIC 1 Online 4x 10GE(LAN) SFP+
PIC 2 Online 4x 10GE(LAN) SFP+
PIC 3 Online 4x 10GE(LAN) SFP+
Slot 6 Online MX960 40GE DPC
PIC 0 Online 10x 1GE
PIC 1 Online 10x 1GE
PIC 2 Online 10x 1GE
PIC 3 Online 10x 1GE
Slot 10 Online MPC 3D 16x 10GE
PIC 0 Online 4x 10GE(LAN) SFP+
PIC 1 Online 4x 10GE(LAN) SFP+
Copyright © 2017, Juniper Networks, Inc.
465
MX960 3D Universal Edge Router Hardware Guide
PIC 2 Online 4x 10GE(LAN) SFP+
PIC 3 Online 4x 10GE(LAN) SFP+
For further description of the output from the command, see the CLI Explorer .
Related
Documentation
•
MX960 Modular Port Concentrator Description on page 89
•
MX960 Modular Port Concentrator LEDs on page 92
•
Troubleshooting the MX960 MPCs on page 496
•
Replacing an MX960 MPC on page 376
Maintaining MX960 PICs
Purpose For optimum router performance, verify the condition of the PICs.
Action On a regular basis:
• Check the LEDs on PIC faceplates. The meaning of the LED states differs for various
PICs. For more information, see the MX Series Interface Module Reference . If the FPC that houses the PIC detects a PIC failure, the FPC generates an alarm message to be sent to the Routing Engine.
• Issue the CLI show chassis fpc pic-status command. The PIC slots in an FPC are numbered from 0 through 1 , top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online DPC 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
Slot 1 Online MX FPC Type 3
PIC 0 Online 1x OC-192 SONET
PIC 1 Online 1x OC-192 SONET
For further description of the output from the command, see the CLI Explorer .
Related
Documentation
•
MX960 PIC Description on page 66
•
Replacing an MX960 PIC on page 382
•
Troubleshooting the MX960 PICs on page 494
•
MX960 PIC Serial Number Label on page 516
Maintaining Cables That Connect to MX960 DPCs, MPCs, MICs, or PICs
Purpose For optimum router performance, verify the condition of the cables that connect to the
DPCs, MPCs, MICs, or PICs.
466 Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
Action On a regular basis:
• Use a standard cable manager or extended cable manager (shown in
and
) to support cables and prevent cables from dislodging or developing stress points.
Figure 179: Standard Cable Manager
Maintenance linkage
Release handles
Figure 180: Extended Cable Manager
• Place excess cable out of the way in the standard or extended cable manager. Do not allow fastened loops of cable to dangle from the connector or cable manager because this stresses the cable at the fastening point. Putting fasteners on the loops helps to maintain their shape.
• Keep the cable connections clean and free of dust and other particles, which can cause drops in the received power level. Always inspect cables and clean them if necessary before connecting an interface.
• Label both ends of the cables to identify them.
Copyright © 2017, Juniper Networks, Inc.
467
MX960 3D Universal Edge Router Hardware Guide
The following guidelines apply specifically to fiber-optic cables:
• When you unplug a fiber-optic cable, always place a rubber safety plug over the transceiver on the faceplate and on the end of the cable.
• Anchor fiber-optic cables to avoid stress on the connectors. Be sure to secure fiber-optic cables so that they do not support their own weight as they hang to the floor. Never let fiber-optic cable hang free from the connector.
• Avoid bending fiber-optic cable beyond its bend radius. An arc smaller than a few inches can damage the cable and cause problems that are difficult to diagnose.
• Frequent plugging and unplugging of fiber-optic cable into and out of optical instruments can cause damage to the instruments that is expensive to repair. Instead, attach a short fiber extension to the optical equipment. Any wear and tear due to frequent plugging and unplugging is then absorbed by the short fiber extension, which is easy and inexpensive to replace.
• Keep fiber-optic cable connections clean. Small microdeposits of oil and dust in the canal of the transceiver or cable connector could cause loss of light, reducing signal power and possibly causing intermittent problems with the optical connection.
To clean the transceivers, use an appropriate fiber-cleaning device, such as RIFOCS
Fiber Optic Adaptor Cleaning Wands (part number 946). Follow the directions for the cleaning kit you use.
After you clean an optical transceiver, make sure that the connector tip of the fiber-optic cable is clean. Use only an approved alcohol-free fiber-optic cable cleaning kit, such as the Opptex Cletop-S Fiber Cleaner. Follow the directions for the cleaning kit you use.
Related
Documentation
•
Maintaining MX960 DPCs on page 450
•
Maintaining MX960 MPCs on page 463
•
Maintaining MX960 MICs on page 462
•
Maintaining MX960 PICs on page 466
Maintaining the MX960 Power Supplies
Purpose For optimum router performance, verify the condition of the power supplies.
Action On a regular basis:
• Check the status of the power supplies by issuing the show chassis environment pem command. The output is similar to the following: user@host> show chassis environment pem
PEM 0 status:
State Online
Temperature OK
DC output OK
468 Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
PEM 1 status:
State Online
Temperature OK
DC output OK
• Make sure that the power and grounding cables are arranged so that they do not obstruct access to other router components.
• Routinely check the status LEDs on the power supply faceplates and the craft interface to determine if the power supplies are functioning normally.
• Check the red and yellow alarm LEDs on the craft interface. Power supply failure or removal triggers an alarm that causes one or both of the LEDs to light. You can display the associated error messages by issuing the following command: user@host> show chassis alarms
• Periodically inspect the site to ensure that the grounding and power cables connected to the router are securely in place and that there is no moisture accumulating near the router.
Related
Documentation
•
MX960 Power Supply LEDs on the Craft Interface on page 17
•
MX960 AC Power Supply Description on page 98
•
MX960 DC Power Supply on page 104
•
Troubleshooting Resources for MX960 Routers on page 487
•
MX960 Site Preparation Checklist on page 124
Verifying the Version of the MX960 Cable Manager
Purpose To verify the version of the cable manager—standard or extended.
Action Issue the show chassis hardware command. In the following output, Extended Cable
Manager in the Description field indicates that the MX960 router has an extended cable manager installed.
user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN10BA496AFA MX960
Midplane REV 03 710-013698 TR0193 MX960 Backplane
Fan Extender REV 02 710-018051 JY5226 Extended Cable
Manager
FPM Board REV 03 710-014974 JZ6867 MX960 Front
Panel Display
PDM Rev 03 740-013110 QCS11035022 Power
Distribution Module
PEM 0 Rev 03 740-013683 QCS1104706T DC Power Entry
Module
PEM 1 Rev 03 740-013683 QCS11047071 DC Power Entry
Module
Copyright © 2017, Juniper Networks, Inc.
469
MX960 3D Universal Edge Router Hardware Guide
470
PEM 2 Rev 03 740-013683 QCS1110700A DC Power Entry
Module
PEM 3 Rev 03 740-013683 QCS11107006 DC Power Entry
Module
Routing Engine 0 REV 06 740-013063 1000690747 RE-S-2000
Routing Engine 1 REV 06 740-013063 1000690717 RE-S-2000
CB 0 REV 07 710-013385 KA3976 MX SCB
CB 1 REV 07 710-013385 KA2127 MX SCB
CB 2 REV 07 710-013385 KA2122 MX SCB
FPC 0 REV 06 710-013699 JZ8103 DPCE 40x 1GE X
CPU REV 06 710-013713 JZ7349 DPC PMB
PIC 0 BUILTIN BUILTIN 10x 1GE(LAN)
Xcvr 0 REV 01 740-011783 PB93302 SFP-LX
Xcvr 1 REV 01 740-011613 AM0703S02F5 SFP-SX
Xcvr 2 REV 01 740-011613 AM0703S02EV SFP-SX
Xcvr 3 REV 01 740-011613 AM0703S02EN SFP-SX
Xcvr 4 REV 01 740-011613 AM0703S02FD SFP-SX
Xcvr 5 REV 01 740-011783 PB93RLK SFP-LX
Xcvr 6 REV 01 740-011783 PB9292T SFP-LX
Xcvr 7 REV 01 740-011613 AM0703S02EC SFP-SX
Xcvr 8 REV 01 740-011783 PB9296B SFP-LX
Xcvr 9 REV 01 740-011783 PB9294X SFP-LX
PIC 1 BUILTIN BUILTIN 10x 1GE(LAN)
Xcvr 0 REV 01 740-011783 PB9330R SFP-LX
Xcvr 1 REV 01 740-011613 PB349PQ SFP-SX
Xcvr 2 REV 01 740-011613 AM0703S02F1 SFP-SX
Xcvr 3 REV 01 740-011613 PB3494J SFP-SX
Xcvr 4 REV 01 740-011613 AM0703S02EY SFP-SX
Xcvr 5 REV 01 740-011613 AM0703S02F3 SFP-SX
Xcvr 6 REV 01 740-011613 AM0703S02EX SFP-SX
Xcvr 7 REV 01 740-011613 AM0703S02EZ SFP-SX
Xcvr 8 REV 01 740-011613 AM0703S02ET SFP-SX
Xcvr 9 REV 01 740-011613 AM0703S02G8 SFP-SX
PIC 2 BUILTIN BUILTIN 10x 1GE(LAN)
Xcvr 0 REV 01 740-011783 PB92938 SFP-LX
Xcvr 1 REV 01 740-011613 AM0703S02E0 SFP-SX
Xcvr 2 REV 01 740-011613 AM0703S02F6 SFP-SX
Xcvr 3 REV 01 740-011613 AM0703S02FB SFP-SX
Xcvr 4 REV 01 740-011613 AM0703S02FA SFP-SX
Xcvr 5 REV 01 740-011613 AM0703S02ED SFP-SX
Xcvr 6 REV 01 740-011783 PB9338R SFP-LX
Xcvr 7 REV 01 740-011613 AM0703S02E1 SFP-SX
Xcvr 8 REV 01 740-011783 PB929AU SFP-LX
Xcvr 9 REV 01 740-011783 PB929AV SFP-LX
PIC 3 BUILTIN BUILTIN 10x 1GE(LAN)
Xcvr 0 REV 01 740-011783 PB9330Q SFP-LX
Xcvr 1 REV 01 740-011613 AM0703S02E8 SFP-SX
Xcvr 2 REV 01 740-011613 PB34FPU SFP-SX
Xcvr 3 REV 01 740-011613 PB34FZ4 SFP-SX
Xcvr 4 REV 01 740-011613 PB34N3Q SFP-SX
Xcvr 5 REV 01 740-011613 AM0703S02EL SFP-SX
Xcvr 6 REV 01 740-011613 AM0703S02EG SFP-SX
Xcvr 7 REV 01 740-011613 AM0703S02EJ SFP-SX
Xcvr 8 REV 01 740-011783 PB9292Y SFP-LX
Xcvr 9 REV 01 740-011783 PB9296A SFP-LX
FPC 3 REV 08 710-014219 KA1048 DPCE 4x 10GE X
CPU REV 06 710-013713 JZ7177 DPC PMB
PIC 0 BUILTIN BUILTIN 1x
10GE(LAN/WAN)
Xcvr 0 REV 01 740-014279 6Z3019A00247 XFP-10G-LR
PIC 1 BUILTIN BUILTIN 1x
Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components
10GE(LAN/WAN)
Xcvr 0 REV 01 740-014279 723019A00434 XFP-10G-LR
PIC 2 BUILTIN BUILTIN 1x
10GE(LAN/WAN)
Xcvr 0 REV 01 740-014289 C712XU00S XFP-10G-SR
PIC 3 BUILTIN BUILTIN 1x
10GE(LAN/WAN)
Xcvr 0 REV 01 740-014279 6Z3019A00216 XFP-10G-LR
Fan Tray 0 REV 03 740-014971 TP0730 Fan Tray
Fan Tray 1 REV 03 740-014971 TP0451 Fan Tray
Related
Documentation
•
MX960 Cable Manager Description on page 19
•
Replacing the MX960 Cable Manager on page 310
Copyright © 2017, Juniper Networks, Inc.
471
MX960 3D Universal Edge Router Hardware Guide
472 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 30
Converting to a Different Type of Power
Supply
•
Converting from AC to DC Power Supplies on an MX960 Router on page 473
•
Converting from DC to AC Power Supplies on an MX960 Router on page 478
Converting from AC to DC Power Supplies on an MX960 Router
The conversion of an MX960 router from AC to DC or DC to AC should be performed with the system completely powered off. A system cannot operate with a mix of AC and DC power supplies. This procedure assumes conversion from normal-capacity power supplies to high-capacity power supplies.
Remove MX960 normal-capacity AC power supplies for power supplies in slots 0, 1, 2,
3 where present. All power supplies should be removed proceeding with the installation of the DC power supplies. To convert from AC to DC, use the following procedures.
Use the following procedures to install the MX960 high capacity DC power supplies for power supply in slots 0, 1, 2, 3 where present.
To remove a normal-capacity AC power supply (see
):
1.
Move the AC input switch in the chassis above the power supply in slot 0 to the off
( O ) position.
2.
Remove the power cord from the AC power source. Follow the ESD and disconnection instructions for your site.
3.
Remove the power cord from the power supply.
4.
While grasping the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops.
5.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
Copyright © 2017, Juniper Networks, Inc.
473
MX960 3D Universal Edge Router Hardware Guide
6.
Pull the power supply straight out of the chassis as shown in
WARNING: Do not touch the power connector on the top of the power supply. It can contain dangerous voltages.
7.
Repeat steps 1-6 for power supplies in slot 1, 2, 3 where present.
Figure 181: Removing an MX960 AC Power Supply
474
Remove the blank panel over the power distribution modules. Store for later reuse. Use the following procedures to install the MX960 high-capacity DC power supplies for power supply in slots 0, 1, 2, and 3, where present.
Copyright © 2017, Juniper Networks, Inc.
Chapter 30: Converting to a Different Type of Power Supply
To install an MX960 DC high-capacity DC power supply:
1.
Verify that the power switch on the power supply is in the off ( O ) position.
2.
On the power supply, rotate the metal cover away from the input mode switch to expose the switch.
3.
Move the input mode switch to position 0 for one feed or position 1 for two feeds (see
NOTE: For a fully redundant configuration in two-feed mode, eight feeds are required. For a nonredundant configuration, four feeds are required.
Figure 182: MX960 with High-Capacity DC Power Supplies Installed
1
0
1
0
Copyright © 2017, Juniper Networks, Inc.
CAUTION: Do not use a pencil, because fragments can break off and cause damage to the power supply.
475
MX960 3D Universal Edge Router Hardware Guide
476
4.
Ensure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cable leads might become active during installation.
5.
Ensure that the release lever below the empty power supply slot is locked in the counterclockwise position.
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
6.
Using both hands, slide the power supply straight into the chassis until the power supply is fully seated in the chassis slot.
The small tab on the metal housing that is controlled by the release lever must be inside of the corresponding slot at the bottom of the power supply. This tab is used to pull the power supply down in the chassis slot, prior to removing the power supply.
7.
While firmly pushing the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever clockwise until it stops.
8.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
9.
Remove the cover protecting the terminal studs on the faceplate.
10.
Remove the nut and washer from each of the terminal studs.
11.
Secure each power cable lug to the terminal studs, first with the split washer, then with the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque to each nut. Do not overtighten the nut. (Use a 7/16-in. [11-mm] torque-controlled driver or socket wrench.) a. On INPUT 0 , attach the positive (+) DC source power cable lug to the RTN (return) terminal as shown in
Figure 74 on page 237 . Repeat this step for
INPUT 1 if using two feeds.
b. On INPUT 0 attach the negative (–) DC source power cable lug to the -48V (input) terminal. Repeat this step for INPUT 1 if using two feeds.if using two feeds.
CAUTION: Ensure that each power cable lug seats flush against the surface of the terminal block as you are tightening the nuts. Ensure that each nut is properly threaded onto the terminal stud. The nut should be able to spin freely with your fingers when it is first placed onto the terminal stud.
Applying installation torque to the nut when improperly threaded may result in damage to the terminal stud.
Copyright © 2017, Juniper Networks, Inc.
Chapter 30: Converting to a Different Type of Power Supply
CAUTION: The maximum torque rating of the terminal studs on the DC power supply is 36 lb-in. (4.0 Nm). The terminal studs may be damaged if excessive torque is applied. Use only a torque-controlled driver or socket wrench to tighten nuts on the DC power supply terminal studs.
NOTE: The DC power supplies in slots PEM0 and PEM1 must be powered by dedicated power feeds derived from feed A , and the DC power supplies in PEM2 and PEM3 must be powered by dedicated power feeds derived from feed B . This configuration provides the commonly deployed A/B feed redundancy for the system. For information about connecting to DC power sources, see
“Electrical Specifications for the MX960 DC Power Supply” on page 169 .
12.
Verify that the power cabling is correct, that the cables are not touching, and that they do not block access to router components or drape where people could trip on them.
13.
Replace the clear plastic cover over the terminal studs on the faceplate.
14.
Switch on the dedicated customer site circuit breaker.
15.
Verify that the INPUT 0 OK or INPUT 1 OK LEDs on the power supply are lit green steadily. If using two feeds, verify that both INPUT 0 OK and INPUT 1 OK LEDs on the power supply are lit steadily. The INPUT OK will be lit amber if that input’s voltage is in reverse polarity. Check the polarity of the power cables to fix the condition (see
and
16.
Move the switch to the on ( | ) position.
17.
Verify that the DC OK LED is lit green steadily. See
for information on MX960 high-capacity DC LEDs.
Table 101: MX960 High-Capacity DC Power Supply LEDs
LEDs
Connected Inputs
DIP
Switch
Position INP-0 OK INP-1 OK DC OK PS FAIL
INP0 connected, INP1 disconnected
INP0 disconnected, INP1 connected
INP0 connected, INP1 connected
0 (1 input)
Green
Off
Green
Off
Green
Green
Green
Green
Green
Off
Off
Off
Copyright © 2017, Juniper Networks, Inc.
477
MX960 3D Universal Edge Router Hardware Guide
Table 101: MX960 High-Capacity DC Power Supply LEDs
(continued)
LEDs
Connected Inputs
DIP
Switch
Position INP-0 OK INP-1 OK DC OK
INP0 connected, INP1 disconnected
INP0 disconnected, INP1 connected
INP0 connected, INP1 connected
1 (2 inputs)
Green
Off
Green
Off
Green
Green
Off
Off
Green
PS FAIL
Red
Red
Off
18.
Repeat steps 1-17 for installing power supplies in slots 1, 2, and 3, where present.
Figure 183: MX960 DC High-Capacity Power Supply Front View
19.
Install a blank panel over the power distribution modules, if available.
Related
Documentation
•
MX960 Power System Overview on page 97
•
Troubleshooting the MX960 Power System on page 498
Converting from DC to AC Power Supplies on an MX960 Router
The conversion of an MX960 router from AC to DC or DC to AC should be performed with the system completely powered off. A system cannot operate with a mix of AC and DC power supplies. This procedure assumes conversion from normal-capacity power supplies to high-capacity power supplies.
478 Copyright © 2017, Juniper Networks, Inc.
Chapter 30: Converting to a Different Type of Power Supply
Remove MX960 normal-capacity AC power supplies for power supply in slots 0, 1, 2, 3 where present. All power supplies should be removed proceeding with the installation of the AC power supplies. To convert from DC to AC, use the following procedures.
To remove a normal-capacity DC power supply (see
):
1.
Switch off the dedicated customer site circuit breaker for the power supply being removed. Follow your site's procedures for electrostatic discharge (ESD).
2.
Move the DC circuit breaker on the power supply faceplate to the off ( O ) position.
3.
Verify that the INPUT OK LEDs on the power supply to be removed are not lit. Also verify that the BREAKER ON LED is not lit.
4.
Make sure that the voltage across the DC power source cable leads is 0 V and that there is no chance that the cables might become active during the removal process.
5.
Remove the clear plastic cover protecting the terminal studs on the faceplate from the power supply in slot 0.
6.
Remove the nut and washer from each of the terminal studs. (Use a 7/16-in.
[11-mm] nut driver or socket wrench.)
7.
Loosen the captive screw on the cable restraint on the lower edge of the power supply faceplate.
8.
Remove the cable lugs from the terminal studs.
9.
Carefully move the power cables out of the way.
10.
While grasping the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops.
11.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
12.
Pull the power supply straight out of the chassis (see
WARNING: Do not touch the power connector on the top of the power supply. It can contain dangerous voltages.
13.
Repeat steps 1-12 for power supplies in slot 1, 2, and 3, where present.
Copyright © 2017, Juniper Networks, Inc.
479
MX960 3D Universal Edge Router Hardware Guide
Figure 184: Removing a DC Power Supply from the MX960 Router
480
Remove the blank panel over the power distribution module, and store for later reuse.
Use the following procedures to install the MX960 high-capacity AC power supplies for power supply in slots 0, 1, 2, and 3, where present.
NOTE: During the upgrade process, you can simultaneously run normal-capacity and high-capacity power supplies. However, it is recommended to upgrade all power supplies to high-capacity power supplies.
To install an MX960 high-capacity AC power supply, use the following procedure (see
).
1.
Verify that the power switch on the power supply is in the off ( O ) position.
2.
Ensure that the release lever below the empty power supply slot is locked in the counterclockwise position (see
).
Copyright © 2017, Juniper Networks, Inc.
Chapter 30: Converting to a Different Type of Power Supply
Figure 185: MX960 with High-Capacity AC Power Supplies Installed
Air exhaust
AC-1 OK
AC-2 OK
DC OK
PS FAIL
AC-1 OK
AC-2 OK
DC OK
PS FAIL
AC-1 OK
AC-2 OK
DC OK
PS FAIL
AC-1 OK
AC-2 OK
DC OK
PS FAIL
Input mode switch
AC Power supplies
Power supply ejectors
Protective earthing ESD point
If necessary, pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever counterclockwise until it stops. Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
3.
On the power supply, rotate the metal cover away from the input mode switch to expose the switch.
4.
Move the input mode switch to position 0 for one feed or position 1 for two feeds (see
Copyright © 2017, Juniper Networks, Inc.
481
MX960 3D Universal Edge Router Hardware Guide
Figure 186: MX960 AC Power Input Mode Switch
482
1
0
1
0
CAUTION: Do not use a pencil, because fragments can break off and cause damage to the power supply.
5.
Using both hands, slide the power supply straight into the chassis until the power supply is fully seated in the chassis slot. The power supply faceplate will protrude beyond the chassis.
The small tab on the metal housing that is controlled by the release lever must be inside of the corresponding slot at the bottom of the power supply (see
Figure 72 on page 230 ). This tab is used to pull the power supply down in the chassis
slot, prior to removing the power supply.
6.
While firmly pushing the handle on the power supply faceplate with one hand, use your other hand to pull the spring-loaded locking pin in the release lever away from the chassis and turn the release lever clockwise until it stops.
7.
Let go of the locking pin in the release lever. Ensure that the pin is seated inside the corresponding hole in the chassis.
8.
Locate a power cord with the type of plug appropriate for your geographical location
(see
“AC Power Cord Specifications for the MX960 Router” on page 165
).
9.
Plug the power cord into the corresponding appliance inlet located in the chassis directly above the power supply. This is the recommend receptacle when using the power supply in one feed mode. If using the power supply in two-feed mode, plug the second power cord into the receptacle on the power supply.
Copyright © 2017, Juniper Networks, Inc.
Chapter 30: Converting to a Different Type of Power Supply
NOTE: Each power supply must be connected to a dedicated AC power feed and a dedicated customer site circuit breaker.
10.
Dress the power cord appropriately. Verify that the power cord does not block the air exhaust and access to router components, and that they do not drape where people could trip on them.
11.
Move the AC input switch above the power supply to the on ( — ) position. This is the only switch you have to turn on if you are using the power supply in one feed mode. If using the power supply in two-feed mode, move the power switch on the power supply to the on position. Remember to turn on both switches when operating the power supply in two-feed mode.
12.
If the power supply is correctly installed and functioning normally, the AC1 OK , AC2 OK
(two-feed mode only), and DC OK LEDs light steadily, and the PS FAIL LED is not lit.
See
13.
Repeat steps 1-12 for installing power supplies in slots 1, 2, and 3, where present
Table 102: MX960 High-Capacity AC Power Supply LEDs
LEDs
Connected
Inputs
DIP Switch
Position AC-1 OK AC-2 OK DC OK PS FAIL
0 (1 input) Green Off Green Off PDM connected, power supply disconnected
PDM disconnected, power supply connected
0 (1 input) Off Green Green Off
PDM connected,
PS connected
PDM connected,
PS disconnected
0 (1 input)
1 (2 inputs)
PDM disconnected, PS connected
1 (2 inputs)
Green
Green
Off
Green
Off
Green
PDM connected,
PS connected
1 (2 inputs) Green Green
NOTE: PDM in the above table stands for Power Distribution Module.
Green
Off
Off
Green
Off
Red
Red
Off
Copyright © 2017, Juniper Networks, Inc.
483
MX960 3D Universal Edge Router Hardware Guide
Related
Documentation
•
MX960 Power System Overview on page 97
•
Troubleshooting the MX960 Power System on page 498
484 Copyright © 2017, Juniper Networks, Inc.
PART 6
Troubleshooting Hardware
•
Troubleshooting Components on page 487
Copyright © 2017, Juniper Networks, Inc.
485
MX960 3D Universal Edge Router Hardware Guide
486 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 31
Troubleshooting Components
•
Troubleshooting Resources for MX960 Routers on page 487
•
Troubleshooting the MX960 Cooling System on page 490
•
Troubleshooting the MX960 DPCs on page 490
•
Troubleshooting the MX960 FPCs on page 492
•
Troubleshooting the MX960 PICs on page 494
•
Troubleshooting the MX960 MICs on page 495
•
Troubleshooting the MX960 MPCs on page 496
•
Troubleshooting the MX960 Power System on page 498
Troubleshooting Resources for MX960 Routers
•
Command-Line Interface on page 487
•
Chassis and Interface Alarm Messages on page 488
•
Alarm Relay Contacts on page 488
•
Craft Interface LEDs on page 488
•
•
Juniper Networks Technical Assistance Center on page 489
Command-Line Interface
The Junos OS command-line interface (CLI) is the primary tool for controlling and troubleshooting router hardware, the Junos OS, routing protocols, and network connectivity. CLI commands display information from routing tables, information specific to routing protocols, and information about network connectivity derived from the ping and traceroute utilities.
You enter CLI commands on one or more external management devices connected to ports on the Routing Engine.
For information about using the CLI to troubleshoot the Junos OS, see the appropriate
Junos OS configuration guide.
Copyright © 2017, Juniper Networks, Inc.
487
MX960 3D Universal Edge Router Hardware Guide
Chassis and Interface Alarm Messages
When the Routing Engine detects an alarm condition, it lights the red or yellow alarm
LED on the craft interface as appropriate. To view a more detailed description of the alarm cause, issue the show chassis alarms command: user@host> show chassis alarms
There are two classes of alarm messages:
• Chassis alarms—Indicate a problem with a chassis component such as the cooling system or power supplies.
• Interface alarms—Indicate a problem with a specific network interface.
Alarm Relay Contacts
The craft interface has two alarm relay contacts for connecting the router to external alarm devices. Whenever a system condition triggers either the red or yellow alarm on the craft interface, the alarm relay contacts are also activated. The alarm relay contacts are located on the upper right of the craft interface.
Craft Interface LEDs
The craft interface is the panel on the front of the router located above the DPC cards that contains LEDs and buttons that allow you to troubleshoot the router.
LEDs on the craft interface include the following:
• Alarm LEDs—One large red circular LED and one large yellow triangular LED, located on the upper right of the craft interface, indicate two levels of alarm conditions. The circular red LED lights to indicate a critical condition that can result in a system shutdown. The triangular yellow LED lights to indicate a less severe condition that requires monitoring or maintenance. Both LEDs can be lit simultaneously. A condition that causes an alarm LED to light also activates the corresponding alarm relay contact on the craft interface.
• Host subsystem LEDs—Three LEDs, MASTER , ONLINE , and OFFLINE , indicate the status of the host subsystem. A green MASTER LED indicates that the host is functioning as the master. The ONLINE LED indicates that the host is online. The OFFLINE LED indicates that the host is installed but the routing engine is offline. The host subsystem LEDs are located on the left of the craft interface and are labeled RE0 and RE1 .
• Power supply LEDs—Two LEDs ( PEM ) indicate the status of each power supply. Green indicates that the power supply is functioning normally. Red indicates that the power supply is not functioning normally. The power supply LEDs are located in the center craft interface, and are labeled 0 through 3 .
• Line card LEDs—Two LEDs, OK and FAIL , indicate the status of each DPC, FPC, or MPC.
Green indicates OK and red indicates a failure. The line card LEDs are located along the bottom of the craft interface.
488 Copyright © 2017, Juniper Networks, Inc.
Chapter 31: Troubleshooting Components
• SCB LEDs—Two LEDs, OK and FAIL , indicate the status of each SCB. Green indicates
OK and red indicates a failure. The SCB LEDs are located on the left of the craft interface along the bottom.
• Fan LEDs—Two LEDs indicate the status of the fans. Green indicates the fans are functioning normally and red indicates a fan has failed. The fan LEDs are located on the upper left of the craft interface.
Component LEDs
The following LEDs are located on various router components and display the status of those components:
• DPC LED—One LED labeled OK/FAIL on each DPC faceplate indicates the DPC's status.
For more information, see the MX Series Interface Module Reference .
• FPC LED—One LED labeled OK/FAIL on each FPC faceplate indicates the FPC's status.
• MPC LED—One LED labeled OK/FAIL on each FPC faceplate indicates the FPC's status.
• MIC LED—One LED labeled OK/FAIL on each MIC faceplate indicates the MIC's status.
For more information, see the MX Series Interface Module Reference .
• PIC LED—One LED labeled OK/FAIL on each PIC faceplate indicates the PIC's status.
For more information, see the MX Series Interface Module Reference .
• SCB LEDs—Three LEDs, labeled FABRIC ACTIVE , FABRIC ONLY , and OK/FAIL , on each
SCB faceplate indicate the status of the SCB. If no LEDs are lit, the master RE might still be booting or the SCB is not receiving power.
• Routing Engine LEDs—Four LEDs, labeled MASTER , HDD , ONLINE , and FAIL on each
Routing Engine faceplate indicate the status of the Routing Engine and hard disk drive.
• Power supply LEDs—Two LEDs on each power supply faceplate indicate the status of that power supply.
Juniper Networks Technical Assistance Center
If you need assistance during troubleshooting, you can contact the Juniper Networks
Technical Assistance Center (JTAC) by using the Web or by telephone.
Related
Documentation
•
Troubleshooting the MX960 Cooling System on page 490
•
Troubleshooting the MX960 DPCs on page 490
•
Troubleshooting the MX960 FPCs on page 492
•
Troubleshooting the MX960 PICs on page 494
•
Troubleshooting the MX960 MPCs on page 496
•
Troubleshooting the MX960 MICs on page 495
•
Troubleshooting the MX960 Power System on page 498
Copyright © 2017, Juniper Networks, Inc.
489
MX960 3D Universal Edge Router Hardware Guide
Troubleshooting the MX960 Cooling System
Problem Description: The fans in a fan tray are not functioning normally.
Solution Follow these guidelines to troubleshoot the fans:
• Check the fan LEDs and alarm LEDs on the craft interface.
• If the red alarm LED on the craft interface lights, use the CLI to get information about the source of an alarm condition: user@host> show chassis alarms .
If the CLI output lists only one fan failure, and the other fans are functioning normally, the fan is most likely faulty and you must replace the fan tray.
• Place your hand near the exhaust vents at the side of the chassis to determine whether the fans are pushing air out of the chassis.
• If a fan tray is removed, a yellow alarm and a red alarm occur.
• The following conditions automatically cause the fans to run at full speed and also trigger the indicated alarm:
• A fan fails (red alarm).
• The router temperature exceeds the “temperature warm” threshold (yellow alarm).
• The temperature of the router exceeds the maximum (“temperature hot”) threshold
(red alarm and automatic shutdown of the power supplies).
Related
Documentation
•
MX960 Alarm LEDs and Alarm Cutoff/Lamp Test Button on page 16
•
Replacing an MX960 Fan Tray on page 327
•
Maintaining the MX960 Air Filter on page 446
•
Maintaining the MX960 Fan Trays on page 446
Troubleshooting the MX960 DPCs
Problem Description: The DPCs are not functioning normally.
490 Copyright © 2017, Juniper Networks, Inc.
Chapter 31: Troubleshooting Components
Solution • Monitor the green LED labeled OK above the DPC on the craft interface as soon as a
DPC is seated in an operating router.
The Routing Engine downloads the DPC software to it under two conditions: the DPC is present when the Routing Engine boots Junos OS, and the DPC is installed and requested online through the CLI or push button on the front panel. The DPC then runs diagnostics, during which the OK LED blinks. When the DPC is online and functioning normally, the OK LED lights green steadily.
• Make sure the DPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight.
• Check the OK/FAIL LED on the DPC and OK and FAIL DPC LEDs on the craft interface.
When the DPC is online and functioning normally, the OK LED lights green steadily.
• Issue the show chassis fpc command to check the status of installed DPCs. As shown in the sample output, the value Online in the column labeled State indicates that the
DPC is functioning normally: user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 41 9 0 1024 15 57
1 Online 43 5 0 1024 16 57
2 Online 43 11 0 1024 16 57
3 Empty
4 Empty
5 Online 42 6 0 1024 16 57
NOTE: The show chassis fpc command displays the status of the DPCs.
For more detailed output, add the detail option. The following example does not specify a slot number, which is optional: user@host> show chassis fpc detail
Slot 2 information:
State Online
Temperature 22 degrees C / 71 degrees F
Total CPU DRAM 1024 MB
Total SRAM 256 MB
Total SDRAM 0 MB
Start time 2006-11-03 07:35:40 PST
Uptime 2 hours, 27 minutes, 1 second
Slot 4 information:
State Online
Temperature 22 degrees C / 71 degrees F
Total CPU DRAM 1024 MB
Total SRAM 256 MB
Total SDRAM 0 MB
Start time 2006-11-03 07:35:48 PST
Uptime 2 hours, 26 minutes, 53 seconds
Slot 7 information:
State Online
Temperature 24 degrees C / 75 degrees F
Copyright © 2017, Juniper Networks, Inc.
491
MX960 3D Universal Edge Router Hardware Guide
Total CPU DRAM 1024 MB
Total SRAM 256 MB
Total SDRAM 0 MB
Start time 2006-11-03 07:35:53 PST
Uptime 2 hours, 26 minutes, 48 seconds
For further description of the output from the commands, see the Junos OS
Administration Library .
Related
Documentation
•
MX960 Dense Port Concentrator Description on page 53
•
Installing an MX960 DPC on page 271
•
Maintaining MX960 DPCs on page 450
Troubleshooting the MX960 FPCs
Problem Description: The FPCs are not functioning normally.
Solution • Monitor the green LED labeled OK above the FPC on the craft interface as soon as an
FPC is seated in an operating router.
The Routing Engine downloads the FPC software to it under two conditions: the FPC is present when the Routing Engine boots Junos OS, and the FPC is installed and requested online through the CLI or push button on the front panel. The FPC then runs diagnostics, during which the OK LED blinks. When the FPC is online and functioning normally, the OK LED lights green steadily.
• Make sure the FPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight.
• Check the OK/FAIL LED on the FPC and OK and FAIL FPC LEDs on the craft interface.
When the FPC is online and functioning normally, the OK LED lights green steadily.
• Issue the show chassis fpc command to check the status of installed FPCs. As shown in the sample output, the value Online in the column labeled State indicates that the
FPC is functioning normally: user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 24 3 0 1024 13 21
1 Empty
2 Online 41 9 0 1024 15 57
3 Online 43 5 0 1024 16 57
4 Online 43 11 0 1024 16 57
5 Online 41 9 0 1024 15 57
6 Online 43 5 0 1024 16 57
7 Empty
8 Empty
9 Empty
10 Online 24 3 0 1024 13 21
11 Empty
492 Copyright © 2017, Juniper Networks, Inc.
Chapter 31: Troubleshooting Components
NOTE: The show chassis fpc command displays the status of the FPCs.
For more detailed output, add the detail option. The following example does not specify a slot number, which is optional: user@host> show chassis fpc detail
Slot 0 information:
State Online
Temperature 24 degrees C / 75 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 128 MB
Total DDR DRAM 2048 MB
Start time: 2008-12-11 16:53:24 PST
Uptime: 15 hours, 2 minutes, 47 seconds
Slot 2 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Slot 3 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Slot 4 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Slot 5 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:22 PST
Uptime: 15 hours, 2 minutes, 49 seconds
Slot 6 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Slot 10 information:
State Online
Temperature 24 degrees C / 75 degrees F
Copyright © 2017, Juniper Networks, Inc.
493
MX960 3D Universal Edge Router Hardware Guide
Total CPU DRAM 1024 MB
Total RLDRAM 128 MB
Total DDR DRAM 2048 MB
Start time: 2008-12-11 16:53:24 PST
Uptime: 15 hours, 2 minutes, 47 seconds
For further description of the output from the commands, see the Junos OS
Administration Library .
Related
Documentation
•
Maintaining MX960 FPCs on page 455
•
Replacing an MX960 FPC on page 361
•
MX960 Flexible PIC Concentrator (FPC) LEDs on page 65
•
Holding an MX960 FPC on page 457
•
Storing an MX960 FPC on page 461
Troubleshooting the MX960 PICs
Problem Description: The PICs are not functioning normally.
Solution • Check the status of each port on a PIC by looking at the LED located on the PIC faceplate. For information about the meaning of LED states on different PICs, see the
MX Series Interface Module Reference .
• Check the status of a PIC by issuing the show chassis fpc pic-status CLI command. The
PIC slots in the FPC are numbered from 0 through 1 , top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online DPC 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
Slot 1 Online MX FPC Type 3
PIC 0 Online 1x OC-192 SONET
PIC 1 Online 1x OC-192 SONET
For further description of the output from the command, see the CLI Explorer .
Related
Documentation
•
MX960 PIC Description on page 66
•
Replacing an MX960 PIC on page 382
•
Maintaining MX960 PICs on page 466
•
MX960 PIC Serial Number Label on page 516
494 Copyright © 2017, Juniper Networks, Inc.
Chapter 31: Troubleshooting Components
Troubleshooting the MX960 MICs
Problem Description: The MICs are not functioning normally.
Solution • Check the status of each port on a MIC by looking at the LED located on the MIC faceplate. For information about the meaning of LED states on different MICs, see the
MX Series Ethernet Services Routers Line Card Guide .
• Check the status of a MIC by issuing the show chassis fpc pic-status CLI command. The
MIC slots in the MPC are labeled PIC 0/1 and PIC 2/3 , top to bottom: user@host> show chassis fpc pic-status
Slot 0 Online DPCE 4x 10GE R EQ
PIC 0 Online 1x 10GE(LAN/WAN) EQ
PIC 1 Online 1x 10GE(LAN/WAN) EQ
PIC 2 Online 1x 10GE(LAN/WAN) EQ
PIC 3 Online 1x 10GE(LAN/WAN) EQ
Slot 1 Online DPCE 40x 1GE R EQ
PIC 0 Online 10x 1GE(LAN) EQ
PIC 1 Online 10x 1GE(LAN) EQ
PIC 2 Online 10x 1GE(LAN) EQ
PIC 3 Online 10x 1GE(LAN) EQ
Slot 2 Online MS-DPC
PIC 0 Online MS-DPC PIC
PIC 1 Online MS-DPC PIC
Slot 3 Online MPC Type 2 3D EQ
PIC 0 Online 1x 10GE XFP
PIC 1 Online 1x 10GE XFP
Slot 4 Online MPC 3D 16x 10GE
PIC 0 Online 4x 10GE(LAN) SFP+
PIC 1 Online 4x 10GE(LAN) SFP+
PIC 2 Online 4x 10GE(LAN) SFP+
PIC 3 Online 4x 10GE(LAN) SFP+
Slot 6 Online MX960 40GE DPC
PIC 0 Online 10x 1GE
PIC 1 Online 10x 1GE
PIC 2 Online 10x 1GE
PIC 3 Online 10x 1GE
Slot 10 Online MPC 3D 16x 10GE
PIC 0 Online 4x 10GE(LAN) SFP+
PIC 1 Online 4x 10GE(LAN) SFP+
PIC 2 Online 4x 10GE(LAN) SFP+
PIC 3 Online 4x 10GE(LAN) SFP+
For further description of the output from the command, see the CLI Explorer .
Related
Documentation
•
MX960 Modular Interface Card Description on page 82
•
Maintaining MX960 MICs on page 462
•
Replacing an MX960 MIC on page 367
Copyright © 2017, Juniper Networks, Inc.
495
MX960 3D Universal Edge Router Hardware Guide
Troubleshooting the MX960 MPCs
Problem Description: The MPCs are not functioning normally.
Solution • Monitor the green LED labeled OK above the MPC on the craft interface as soon as an
MPC is seated in an operating router.
The Routing Engine downloads the MPC software to it under two conditions: The MPC is present when the Routing Engine boots Junos OS, and the MPC is installed and requested online through the CLI or push button on the front panel. The MPC then runs diagnostics, during which the OK LED blinks. When the MPC is online and functioning normally, the OK LED lights green steadily.
• Make sure the MPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight.
• Check the OK/FAIL LED on the MPC and OK and FAIL line card LEDs on the craft interface. When the MPC is online and functioning normally, the OK LED lights green steadily.
• Issue the show chassis fpc command to check the status of installed MPCs. As shown in the sample output, the value Online in the column labeled State indicates that the
MPC is functioning normally: user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 36 3 0 2048 14 13
1 Online 40 5 0 2048 26 13
2 Online 41 6 0 1024 7 43
3 Online 43 5 0 1024 16 57
4 Online 24 3 0 1024 13 21
5 Empty
6 Online 43 5 0 1024 16 57
7 Empty
8 Empty
9 Empty
10 Online 24 3 0 1024 13 21
11 Empty
NOTE: The show chassis fpc command displays the status of the MPCs.
For more detailed output, add the detail option. The following example does not specify a slot number, which is optional: user@host> show chassis fpc detail
Slot 0 information:
State Online
Temperature 33 degrees C / 91 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
496 Copyright © 2017, Juniper Networks, Inc.
Chapter 31: Troubleshooting Components
Total DDR DRAM 4096 MB
Start time: 2009-12-22 12:26:54 PST
Uptime: 6 days, 3 hours, 8 minutes, 51 seconds
Max Power Consumption 330 Watts
Slot 1 information:
State Online
Temperature 32 degrees C / 89 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2009-12-22 12:26:54 PST
Uptime: 6 days, 3 hours, 8 minutes, 51 seconds
Max Power Consumption 365 Watts
Slot 2 information:
State Online
Temperature 41 degrees C / 105 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 128 MB
Total DDR DRAM 2048 MB
Start time: 2009-12-22 12:26:46 PST
Uptime: 6 days, 3 hours, 8 minutes, 59 seconds
Max Power Consumption 265 Watts
Slot 3 information:
State Online
Temperature 36 degrees C / 96 degrees F
Total CPU DRAM 2048 MB
Total RLDRAM 806 MB
Total DDR DRAM 2632 MB
Start time: 2009-12-22 12:27:04 PST
Uptime: 6 days, 3 hours, 8 minutes, 41 seconds
Max Power Consumption 450 Watts
Slot 4 information:
State Online
Temperature 40 degrees C / 104 degrees F
Total CPU DRAM 2048 MB
Total RLDRAM 1324 MB
Total DDR DRAM 5120 MB
Start time: 2009-12-22 12:27:02 PST
Uptime: 6 days, 3 hours, 8 minutes, 43 seconds
Max Power Consumption 440 Watts
Slot 6 information:
State Online
Temperature 29 degrees C / 84 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2008-12-11 16:53:18 PST
Uptime: 15 hours, 2 minutes, 53 seconds
Max Power Consumption 365 Watts
Slot 10 information:
State Online
Temperature 24 degrees C / 75 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 128 MB
Total DDR DRAM 2048 MB
Start time: 2008-12-11 16:53:24 PST
Copyright © 2017, Juniper Networks, Inc.
497
MX960 3D Universal Edge Router Hardware Guide
Uptime: 15 hours, 2 minutes, 47 seconds
Max Power Consumption 440 Watts
For further description of the output from the commands, see the Junos OS
Administration Library .
Related
Documentation
•
MX960 Modular Port Concentrator Description on page 89
•
Maintaining MX960 MPCs on page 463
•
Replacing an MX960 MPC on page 376
Troubleshooting the MX960 Power System
Problem Description: The power system is not functioning normally.
Solution • Check the LEDs on each power supply faceplate.
• If an AC power supply is correctly installed and functioning normally, the AC OK and
DC OK LED’s light steadily, and the PS FAIL LED is not lit.
• If a DC power supply is correctly installed and functioning normally, the PWR_OK ,
INPUT OK , and BREAKER ON LED’s light steadily.
• Issue the CLI show chassis environment pem command to check the status of installed power supply modules. As shown in the sample output, the value Online in the rows labeled State indicates that each power supply is functioning normally: user@host> show chassis environment pem
PEM 0 status:
State Online
Temperature OK
DC output OK
PEM 1 status:
State Online
Temperature OK
DC output OK
If a power supply is not functioning normally, perform the following steps to diagnose and correct the problem:
• If a red alarm condition occurs, issue the show chassis alarms command to determine the source of the problem.
• Check that the AC input switch ( — ) or DC circuit breaker ( | ) is in the on position and that the power supply is receiving power.
• Verify that the source circuit breaker has the proper current rating. Each power supply must be connected to a separate source circuit breaker.
• Verify that the AC power cord or DC power cables from the power source to the router are not damaged. If the insulation is cracked or broken, immediately replace the cord or cable.
498 Copyright © 2017, Juniper Networks, Inc.
Chapter 31: Troubleshooting Components
• Connect the power supply to a different power source with a new power cord or power cables. If the power supply status LEDs indicate that the power supply is not operating normally, the power supply is the source of the problem. Replace the power supply with a spare.
• If all power supplies have failed, the system temperature might have exceeded the threshold, causing the system to shut down.
NOTE: If the system temperature exceeds the threshold, the Junos OS shuts down all power supplies so that no status is displayed.
The Junos OS also can shut down one of the power supplies for other reasons. In this case, the remaining power supplies provide power to the router, and you can still view the system status through the CLI or display.
To restart a high-capacity AC power supply after a shut down due to an over-temperature situation:
1.
Move the power switch on the power supply to the off (o) position.
2.
Turn off power to where the AC line goes into the power distribution module (PDM) area.
3.
Wait for the power supply LEDs to fade out and for the fans inside the power supply to shutdown. This can take up to 10 seconds.
CAUTION: Do not attempt to power-on the power supply if the LED is still lit and the fan is still running. If you do, the router will not reboot.
4.
Turn on power to where the AC line goes into the power distribution module (PDM) area.
5.
Move the power switch on the power supply to the on (|) position.
6.
Verify that the LEDs on the power supply faceplate are properly lit.
7.
Issue the CLI show chassis environment pem command and verify the State is ONLINE and the Temperature is OK .
Copyright © 2017, Juniper Networks, Inc.
499
MX960 3D Universal Edge Router Hardware Guide
To restart a high-capacity DC power supply after a shut down due to an over-temperature situation:
1.
Switch off the circuit breaker(s) on the DC distribution panel to remove power to the chassis and power supplies.
2.
Switch on the circuit breaker(s) on the distribution panel to power up the chassis and power supplies.
NOTE: The power switch on the power supplies is not part of the outer or inner DC circuits and therefore does not need to be switched off when restarting the chassis.
NOTE: If output power is not load-balancing correctly in the same zone on an MX960 with a high-capacity AC or DC power supply module, connect two feeds and change the DIP switch to 1 to boost the voltage on the power supply module.
500 Copyright © 2017, Juniper Networks, Inc.
Chapter 31: Troubleshooting Components
Each High Capacity AC or DC power supply accepts two AC or DC feeds in two unique
AC or DC receptacles. It is possible to operate with one feed, but there is a reduction in the power supply output. The DIP switch must be set according to the number of AC or
DC feeds that are present for the power supply.
Figure 187: MX960 AC Power Input Mode Switch
1
0
1
0
• Position – 0 indicates that only one AC or DC feed is provided.
• Position – 1 indicates that two AC or DC feeds are provided.
To check the DIP switch position:
1.
Issue the show chassis power command and check to see how many feeds are connected. The following example shows there are two AC input feeds connected for PEM 0 and one AC input feed connected for PEM 1. This indicates that the DIP switch for PEM 0 is in position 1 and the DIP switch for PEM 1 is in position 0. These are the proper settings.
# run show chassis power
PEM 0:
State: Online
AC input: OK (2 feed expected, 2 feed connected)
Capacity: 4100 W (maximum 4100 W)
DC output: 855 W (zone 0, 15 A at 57 V, 20% of capacity)
PEM 1:
State: Online
AC input: OK (1 feed expected, 1 feed connected)
Capacity: 1700 W (maximum 4100 W)
DC output: 969 W (zone 1, 17 A at 57 V, 57% of capacity)
2.
Issue the show chassis alarms command to see if there are any active alarms on the
DIP switch:
> show chassis alarms
Copyright © 2017, Juniper Networks, Inc.
501
MX960 3D Universal Edge Router Hardware Guide
4 alarms currently active
Alarm time Class Description 2013-01-11 14:48:26 UTC Minor PEM 0 Dipswitch 0
Feed Connection 2
3.
If the show chassis alarms output shows an alarm on Dipswitch , issue the show chassis power command to check the DIP switch position.
# run show chassis power
PEM 0:
State: Online
AC input: OK (1 feed expected, 2 feed connected)
Capacity: 4100 W (maximum 4100 W)
DC output: 855 W (zone 0, 15 A at 57 V, 20% of capacity)
In this example, the DIP switch is in the wrong position since there is one AC feed expected but two AC feeds are connected. Change the DIP switch to position 1. This should clear the alarm.
NOTE: Changing the DIP switch position does not impact traffic. However, it is always recommended to do so in a maintenance window.
Related
Documentation
•
MX960 AC Power Supply Description on page 98
•
MX960 DC Power Supply on page 104
•
Replacing an MX960 AC Power Supply on page 391
•
Replacing an MX960 DC Power Supply on page 395
•
Troubleshooting Resources for MX960 Routers on page 487
502 Copyright © 2017, Juniper Networks, Inc.
PART 7
Contacting Customer Support and
Returning the Chassis or Components
•
Contacting Customer Support on page 505
•
Locating Component Serial Numbers on page 507
•
Packing and Returning Components on page 523
•
Safety and Compliance Information on page 529
Copyright © 2017, Juniper Networks, Inc.
503
MX960 3D Universal Edge Router Hardware Guide
504 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 32
Contacting Customer Support
•
Contacting Customer Support on page 505
Contacting Customer Support
You can contact Juniper Networks Technical Assistance Center (JTAC) 24 hours a day,
7 days a week in one of the following ways:
• On the Web, using the Case Manager link at: http://www.juniper.net/support/
• By telephone:
From the US and Canada: 1-888-314-JTAC
From all other locations: 1-408-745-9500
If contacting JTAC by phone, enter your 11-digit case number followed by the # key if this is an existing case, or press the * key to be routed to the next available support engineer.
When requesting support from JTAC by telephone, be prepared to provide the following information:
• Your existing case number, if you have one
• Details of the failure or problem
• Type of activity being performed on the platform when the problem occurred
• Configuration data using one or more of the show commands
Related
Documentation
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
Copyright © 2017, Juniper Networks, Inc.
505
MX960 3D Universal Edge Router Hardware Guide
506 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 33
Locating Component Serial Numbers
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
MX960 Routing Engine Serial Number Label on page 509
•
MX960 Chassis Serial Number Label on page 510
•
MX960 Craft Interface Serial Number Label on page 511
•
MX960 Fan Tray Serial Number Label on page 512
•
MX960 Power Supply Serial Number Labels on page 512
•
MX960 MIC Serial Number Label on page 514
•
MX960 MPC Serial Number Label on page 515
•
MX960 PIC Serial Number Label on page 516
•
MX960 FPC Serial Number Label on page 517
•
MX960 DPC Serial Number Label on page 518
•
MX960 SCB Serial Number Label on page 519
•
Contacting Customer Support on page 520
Displaying MX960 Router Components and Serial Numbers
Before contacting Juniper Networks, Inc. to request a Return Materials Authorization
(RMA), you must find the serial number on the router or component. To display all of the router components and their serial numbers, enter the following command-line interface
(CLI) command: user@host> show chassis hardware
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN107FC5DAFA MX960
Midplane REV 02 710-013698 CC6220 MX960 Midplane
FPM Board REV 01 710-014974 JS4208 MX960 Front Panel Displ ay
PIM Rev 02 740-013110 QCS10375009 Power Inlet Module
PEM 0 Rev 01 740-013682 QCS10374009 PS 1.7kW; 200-240VAC in
PEM 1 Rev 01 740-013682 QCS10374029 PS 1.7kW; 200-240VAC in
Routing Engine 0 REV 02 740-013063 1000639065 RE-S-2000
Routing Engine 1 REV 04 740-013063 1000664335 RE-S-2000
CB 0 REV 02.6 710-013385 JM7908 MX960 SCB
CB 1 REV 03 710-013385 JS9412 MX960 SCB
FPC 2 REV 03 710-013699 JS4284 MX960 40GE DPC
Copyright © 2017, Juniper Networks, Inc.
507
MX960 3D Universal Edge Router Hardware Guide
508
CPU REV 04 710-013713 JS9401 MX960 DPC PMB
PIC 0 BUILTIN BUILTIN 10x 1GE
Xcvr 0 REV 01 740-011613 P9F1ANQ SFP-SX
Xcvr 1 REV 01 740-011613 P9F1ANB SFP-SX
Xcvr 2 REV 01 740-011613 P9F18GT SFP-SX
Xcvr 3 REV 01 740-011613 P9F1AP1 SFP-SX
Xcvr 4 REV 01 740-011613 P9F1ANF SFP-SX
Xcvr 5 REV 01 740-011613 P9F1ANK SFP-SX
Xcvr 6 REV 01 740-011613 P9F1AP2 SFP-SX
Xcvr 7 REV 01 740-011613 P9F1ALL SFP-SX
Xcvr 8 REV 01 740-011613 P9F1ANM SFP-SX
Xcvr 9 REV 01 740-011613 P9F1ANU SFP-SX
PIC 1 BUILTIN BUILTIN 10x 1GE
Xcvr 0 REV 01 740-011613 P9F18HA SFP-SX
Xcvr 1 REV 01 740-011613 P9F18GY SFP-SX
Xcvr 2 REV 01 740-011613 P9F18GL SFP-SX
Xcvr 3 REV 01 740-011613 P9F18H3 SFP-SX
Xcvr 4 REV 01 740-011613 P9F18GQ SFP-SX
Xcvr 5 REV 01 740-011613 P9F18GX SFP-SX
Xcvr 6 REV 01 740-011613 P9F18GK SFP-SX
Xcvr 7 REV 01 740-011613 P9F18H7 SFP-SX
Xcvr 8 REV 01 740-011613 P9F13JV SFP-SX
Xcvr 9 REV 01 740-011613 P9F18GF SFP-SX
PIC 2 BUILTIN BUILTIN 10x 1GE
Xcvr 0 NON-JNPR P5A08SR SFP-T
Xcvr 1 REV 01 740-007327 435040B00332 SFP-LX
Xcvr 2 REV 01 740-011782 P8J1SZ4 SFP-SX
Xcvr 3 REV 01 740-011782 P8J1SYH SFP-SX
Xcvr 4 REV 01 740-011613 P9F18HB SFP-SX
Xcvr 5 REV 01 740-011613 P9F1AN9 SFP-SX
PIC 3 BUILTIN BUILTIN 10x 1GE
Xcvr 0 REV 01 740-011613 P9F18GE SFP-SX
Xcvr 1 REV 01 740-011613 P9F18GW SFP-SX
Xcvr 2 REV 01 740-011613 P9F18H0 SFP-SX
Xcvr 3 REV 01 740-011613 P9F18GG SFP-SX
Xcvr 4 REV 01 740-011613 P9F18GD SFP-SX
Xcvr 5 REV 01 740-013111 60882058 SFP-T
Xcvr 6 REV 01 740-011613 P9F18GN SFP-SX
Xcvr 8 REV 01 740-011613 P9F18GV SFP-SX
Xcvr 9 REV 01 740-011613 P9F18H5 SFP-SX
FPC 4 REV 04 710-014219 JS4980 MX960 4 XGE DPC
CPU REV 03 710-013713 JS4164 MX960 DPC PMB
PIC 0 BUILTIN BUILTIN 1x 10GE(LAN/WAN)
Xcvr 0 NON-JNPR K9J02RS XFP-10G-LR
PIC 1 BUILTIN BUILTIN 1x 10GE(LAN/WAN)
Xcvr 0 NON-JNPR K9J03CY XFP-10G-LR
PIC 2 BUILTIN BUILTIN 1x 10GE(LAN/WAN)
Xcvr 0 REV 01 740-014279 62E204N00004 XFP-10G-LR
PIC 3 BUILTIN BUILTIN 1x 10GE(LAN/WAN)
FPC 7 REV 04 710-014219 JW7120 MX960 4 XGE DPC
CPU REV 04 710-013713 JS4236 MX960 DPC PMB
PIC 0 BUILTIN BUILTIN 1x 10GE(LAN/WAN)
Xcvr 0 NON-JNPR K9J02T3 XFP-10G-LR
PIC 1 BUILTIN BUILTIN 1x 10GE(LAN/WAN)
Xcvr 0 NON-JNPR K9J03BQ XFP-10G-LR
PIC 2 BUILTIN BUILTIN 1x 10GE(LAN/WAN)
Xcvr 0 NON-JNPR K9J03DA XFP-10G-LR
PIC 3 BUILTIN BUILTIN 1x 10GE(LAN/WAN)
Xcvr 0 NON-JNPR K9J02Q0 XFP-10G-LR
Fan Tray 0 REV 01 740-014971 FT0655 MX960 Fan Tray
Fan Tray 1 REV 01 740-014971 FT0653 MX960 Fan Tray
Copyright © 2017, Juniper Networks, Inc.
Chapter 33: Locating Component Serial Numbers
Most components also have a small rectangular serial number ID label (see
) attached to the component body.
Figure 188: Serial Number ID Label
Related
Documentation
•
MX960 Chassis Serial Number Label on page 510
•
MX960 Craft Interface Serial Number Label on page 511
•
MX960 DPC Serial Number Label on page 518
•
MX960 FPC Serial Number Label on page 517
•
MX960 PIC Serial Number Label on page 516
•
MX960 MPC Serial Number Label on page 515
•
MX960 MIC Serial Number Label on page 514
•
MX960 Power Supply Serial Number Labels on page 512
•
MX960 Routing Engine Serial Number Label on page 509
•
MX960 SCB Serial Number Label on page 519
MX960 Routing Engine Serial Number Label
The serial number label is located on the left side of the top of the Routing Engine (see
and
Figure 189: Routing Engine Serial Number Label
Serial number ID label
AAAA0000
Copyright © 2017, Juniper Networks, Inc.
509
MX960 3D Universal Edge Router Hardware Guide
Figure 190: RE-S-X6-64G Routing Engine Serial Number Label
Related
Documentation
•
Replacing an MX960 Routing Engine on page 333
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Contacting Customer Support on page 505
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Guidelines for Packing Hardware Components for Shipment on page 524
MX960 Chassis Serial Number Label
The chassis serial number is located on the side of the chassis (see
510 Copyright © 2017, Juniper Networks, Inc.
Chapter 33: Locating Component Serial Numbers
Figure 191: MX960 Chassis Serial Number Label
OK FAIL
0
ONLINE
OK
FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
0
1
FAN
OK FAIL
5
ONLINE
MASTER
ONLINE
RE0
OK FAIL
OFFLINE
RE1
OK FAIL
0
ONLINE
1
ONLINE
OK FAIL
2 6
ONLINE
YELL M
ACO/LT
OK FAIL
7
ONLINE
OK
FAIL
NC C NO
NC
OK FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK FAIL
11
ONLINE
Related
Documentation
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
MX960 Craft Interface Serial Number Label on page 511
•
MX960 DPC Serial Number Label on page 518
•
MX960 FPC Serial Number Label on page 517
•
MX960 PIC Serial Number Label on page 516
•
MX960 MPC Serial Number Label on page 515
•
MX960 MIC Serial Number Label on page 514
•
MX960 Power Supply Serial Number Labels on page 512
•
MX960 Routing Engine Serial Number Label on page 509
•
MX960 SCB Serial Number Label on page 519
MX960 Craft Interface Serial Number Label
The serial number is located on the back of the craft interface panel (see
Copyright © 2017, Juniper Networks, Inc.
511
MX960 3D Universal Edge Router Hardware Guide
Figure 192: Craft Interface Serial Number Label
Serial number ID label
AA1234
OK FAIL
0
ONLINE
OK FAIL
1
ONLINE
OK FAIL
2
ONLINE
PEM 0 1 2 3
OK FAIL
OK FAIL
3
ONLINE
4
ONLINE
FAN
0
1
OK FAIL
5
ONLINE
MASTER
RE0
OK FAIL
ONLINE
OFFLINE
RE1
OK
FAIL
0
ONLINE
1
ONLINE
OK
FAIL
2 6
ONLINE
OK
FAIL
7
ONLINE
ACO/LT
YELLOW ALARM
RED ALARM
OK FAIL
NC C
NO NC
OK FAIL
C NO
8
ONLINE
9
ONLINE
OK FAIL
10
ONLINE
OK
FAIL
11
ONLINE
Related
Documentation
•
Replacing the MX960 Craft Interface on page 307
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Contacting Customer Support on page 505
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Guidelines for Packing Hardware Components for Shipment on page 524
MX960 Fan Tray Serial Number Label
The serial number is located on the top left-hand corner of the fan tray, near the captive thumbscrew (see
Figure 193: MX960 Fan Tray Serial Number Label
Serial number ID label
AA1234
Related
Documentation
•
Replacing the MX960 Craft Interface on page 307
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Contacting Customer Support on page 505
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Guidelines for Packing Hardware Components for Shipment on page 524
MX960 Power Supply Serial Number Labels
The serial number label is located on the AC power supply faceplate under the on/off switch (see
512 Copyright © 2017, Juniper Networks, Inc.
Chapter 33: Locating Component Serial Numbers
The serial number label is located on the DC power supply faceplate under the circuit breaker switch (see
Figure 194: AC Power Supply Serial Number Label
Figure 195: DC Power Supply Serial Number Label
Related
Documentation
•
Replacing an MX960 AC Power Supply on page 391
•
Replacing an MX960 DC Power Supply on page 395
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Contacting Customer Support on page 505
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Guidelines for Packing Hardware Components for Shipment on page 524
Copyright © 2017, Juniper Networks, Inc.
513
MX960 3D Universal Edge Router Hardware Guide
MX960 MIC Serial Number Label
The serial number label location varies per MIC (see
and
). The exact location may be slightly different on different MICs, depending on the placement of components on the MIC board (see
,
, and
).
Figure 196: 2-Port MIC Serial Number Label Figure 197: 4-Port MIC Serial Number Label
Serial number
ID label
Serial number
ID label
514 Copyright © 2017, Juniper Networks, Inc.
Chapter 33: Locating Component Serial Numbers
Figure 198: 20-Port MIC Serial Number Label Figure 199: 40-Port MIC Serial Number Label
Serial number
ID label
Serial number
ID label
Related
Documentation
•
Replacing an MX960 MIC on page 367
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Contacting Customer Support on page 505
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Guidelines for Packing Hardware Components for Shipment on page 524
MX960 MPC Serial Number Label
The serial number label is near the connectors located on the left side of the MPC when it is oriented vertically (see
Copyright © 2017, Juniper Networks, Inc.
515
MX960 3D Universal Edge Router Hardware Guide
Figure 200: MPC Serial Number Label
Serial number ID label (yellow, on opposite side)
Related
Documentation
•
Replacing an MX960 MPC on page 376
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Contacting Customer Support on page 505
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Guidelines for Packing Hardware Components for Shipment on page 524
MX960 PIC Serial Number Label
The serial number label is located on the right side of the PIC (see
when the PIC is vertically oriented (as it would be installed in the router). The exact location may be slightly different on different PICs, depending on the placement of components on the PIC board.
516 Copyright © 2017, Juniper Networks, Inc.
Figure 201: PIC Serial Number Label
Chapter 33: Locating Component Serial Numbers
Related
Documentation
•
Replacing an MX960 PIC on page 382
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Contacting Customer Support on page 505
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Guidelines for Packing Hardware Components for Shipment on page 524
MX960 FPC Serial Number Label
The serial number label is located on the center of the right side of the FPC (see
Copyright © 2017, Juniper Networks, Inc.
517
MX960 3D Universal Edge Router Hardware Guide
Figure 202: FPC Serial Number Label
Serial number ID label
AA1234
Related
Documentation
•
Replacing an MX960 FPC on page 361
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Contacting Customer Support on page 505
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Guidelines for Packing Hardware Components for Shipment on page 524
MX960 DPC Serial Number Label
The serial number label is located on the center of the right side of the DPC (see
518 Copyright © 2017, Juniper Networks, Inc.
Chapter 33: Locating Component Serial Numbers
Figure 203: DPC Serial Number Label
1/0
TUNNEL
LINK
2/0
TUNNEL
LINK
3/0
TUNNEL
LINK
OK/FAIL
0/0
TUNNEL
LINK
Serial number
ID label
AA567 8
Related
Documentation
•
Replacing an MX960 DPC on page 355
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Contacting Customer Support on page 505
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Guidelines for Packing Hardware Components for Shipment on page 524
MX960 SCB Serial Number Label
The serial number is located on the right side of the top of the SCB (see
Copyright © 2017, Juniper Networks, Inc.
519
MX960 3D Universal Edge Router Hardware Guide
Figure 204: SCB Serial Number Label
Serial number
ID label
Related
Documentation
•
Replacing an MX960 SCB on page 409
•
Displaying MX960 Router Components and Serial Numbers on page 507
•
Contacting Customer Support on page 505
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Guidelines for Packing Hardware Components for Shipment on page 524
Contacting Customer Support
You can contact Juniper Networks Technical Assistance Center (JTAC) 24 hours a day,
7 days a week in one of the following ways:
• On the Web, using the Case Manager link at: http://www.juniper.net/support/
• By telephone:
From the US and Canada: 1-888-314-JTAC
From all other locations: 1-408-745-9500
If contacting JTAC by phone, enter your 11-digit case number followed by the # key if this is an existing case, or press the * key to be routed to the next available support engineer.
520 Copyright © 2017, Juniper Networks, Inc.
Chapter 33: Locating Component Serial Numbers
When requesting support from JTAC by telephone, be prepared to provide the following information:
• Your existing case number, if you have one
• Details of the failure or problem
• Type of activity being performed on the platform when the problem occurred
• Configuration data using one or more of the show commands
Related
Documentation
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
Copyright © 2017, Juniper Networks, Inc.
521
MX960 3D Universal Edge Router Hardware Guide
522 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 34
Packing and Returning Components
•
Contacting Customer Support to Obtain Return Material Authorization on page 523
•
Guidelines for Packing Hardware Components for Shipment on page 524
•
Packing the MX2020 Router for Shipment on page 524
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
Contacting Customer Support to Obtain Return Material Authorization
If you are returning a device or hardware component to Juniper Networks for repair or replacement, obtain a Return Material Authorization (RMA) number from Juniper Networks
Technical Assistance Center (JTAC).
After locating the serial number of the device or hardware component you want to return, open a Case with Juniper Networks Technical Assistance Center (JTAC) on the Web or by telephone.
Before you request an RMA number from JTAC, be prepared to provide the following information:
• Your existing case number, if you have one
• Serial number of the component
• Your name, organization name, telephone number, fax number, and shipping address
• Details of the failure or problem
• Type of activity being performed on the device when the problem occurred
• Configuration data displayed by one or more show commands
You can contact JTAC 24 hours a day, seven days a week on the Web or by telephone:
• Case Manager at CSC: http://www.juniper.net/cm/
• Telephone: +1-888-314-JTAC1-888-314-5822, toll free in U.S., Canada, and Mexico
NOTE: For international or direct-dial options in countries without toll free numbers, see http://www.juniper.net/support/requesting-support.html
.
Copyright © 2017, Juniper Networks, Inc.
523
MX960 3D Universal Edge Router Hardware Guide
If you are contacting JTAC by telephone, enter your 11-digit case number followed by the pound (#) key for an existing case, or press the star (*) key to be routed to the next available support engineer.
The support representative validates your request and issues an RMA number for return of the component.
Related
Documentation
•
Prevention of Electrostatic Discharge Damage on page 551
Guidelines for Packing Hardware Components for Shipment
To pack and ship individual components:
• When you return components, make sure they are adequately protected with packing materials and packed so that the pieces are prevented from moving around inside the carton.
• Use the original shipping materials if they are available.
• Place individual components in antistatic bags.
• Write the RMA number on the exterior of the box to ensure proper tracking.
CAUTION: Do not stack any of the hardware components.
Related
Documentation
•
Returning a Hardware Component to Juniper Networks, Inc. on page 527
•
Contacting Customer Support on page 505
Packing the MX2020 Router for Shipment
To pack the router for shipment:
1.
Retrieve the shipping crate and packing materials in which the router was originally shipped. If you do not have these materials, contact your Juniper Networks representative about approved packaging materials.
2.
On the console or other management device connected to the master CB-RE, enter
CLI operational mode and issue the following command to shut down the router software. (If two CB-REs are installed, also issue the command on the backup CB-RE.) user@host> request system halt
Wait until a message appears on the console confirming that the operating system has halted.
For more information about the command, see the Junos OS System Basics and Services
Command Reference .
524 Copyright © 2017, Juniper Networks, Inc.
Chapter 34: Packing and Returning Components
3.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
4.
Shut down power to the router by switching the AC or DC circuit breaker for all PDMs to the off ( O ) position.
5.
Disconnect power from the router.
6.
Remove the cables that connect to all external devices.
7.
Remove all field replaceable units (FRUs) from the router.
8.
Attach the front and rear shipping covers.
CAUTION: Apply force to any other parts of chassis other than the shipping covers can damage the chassis.
9.
Remove the router from the rack.
• Using a pallet jack with attachment:
• Install the pallet jack attachment to a pallet jack. Position the pallet jack in front of the rack, and unscrew and remove the mounting screws from the front mounting flange on the rack.
NOTE: The pallet jack attachment fits only on a standard pallet jack.
The standard pallet jack is approximately 48 in. (121.92 cm) deep x
27 in. (68.58 cm) wide.
• A minimum of four people can then slide the router onto the pallet jack by using the handles on the shipping covers. Attach the four shipping brackets and hardware to the pallet jack attachment. Secure the brackets to the router chassis.
• Position the router in front of the shipping crate and raise the pallet jack.
Copyright © 2017, Juniper Networks, Inc.
525
MX960 3D Universal Edge Router Hardware Guide
• Remove the shipping brackets and hardware, and set them aside.
• Guide the router in the shipping crate.
Using a router transport kit:
• Position the router transport platform in front of the rack, and adjust the four leveling mounts using an 8 mm Allen wrench to align the platform with the bottom of the mounting shelf and the chassis.
• Unscrew and remove the mounting screws from the front mounting flange on the rack.
• A minimum of four people can then slide the router onto the router transport platform by using the handles on the shipping covers.
• Secure the four toggle latches to the router transport platform.
• Using a two person team, adjust the height on the router transport platform to install the router transport mounting plates and wheel assembly.
WARNING: Do not raise the router more than 1 in. (2.54 cm). Doing so can make the router unstable.
• Attach the router transport mounting plates and wheel assembly to both sides of the chassis using the captive screws, tighten to secure.
NOTE: You may have to adjust the wheel assembly to installed the router transport mounting plates.
• Using a two person team, crank the handles 4-5 times until the router is lifted approximately 1 in. (2.54 cm).
WARNING: Do not raise the router transport over the required limit.
Doing so can make the router unstable during transport.
• Unlatch the four toggle latches that secure the router transport platform to the router mounting plate and wheel assembly.
• Remove the router transport platform away from the bottom of the router, and set aside
• Position the crate door in front of the shipping crate and secure the two latches.
• Guide the router up the ramp and into the shipping crate.
• Lower the router until the chassis is resting firmly onto the shipping crate platform.
• Remove the router transport mounting plates and wheel assembly from the chassis.
526 Copyright © 2017, Juniper Networks, Inc.
Chapter 34: Packing and Returning Components
WARNING: We recommend using a pallet jack with attachment or a router transport kit. Not using one of these recommended installation mechanisms can result in personal injury or damage to the equipment.
10.
Reattach the shipping brackets to the router chassis and the shipping crate pallet.
11.
Cover the router with an ESD bag and place the packing foam on top of and around the router.
12.
Replace the accessory box on top of the packing foam.
13.
Securely place the crate cover over the router.
14.
Close all latches to secure the shipping crate to the pallet.
15.
Write the RMA number on the exterior of the box to ensure proper tracking.
Related
Documentation
• Preventing Electrostatic Discharge Damage to an MX2020 Router
• Powering Off the DC-Powered MX2020 Router
• Powering Off the AC-Powered MX2020 Router
• Replacing an MX2020 Three-Phase Delta AC Power Cord
• Replacing an MX2020 Three-Phase Wye AC Power Cord
• Disconnecting an MX2020 DC Power Distribution Module Cable
• Installing the Router Transport Kit on the MX2020 Router
Returning a Hardware Component to Juniper Networks, Inc.
If a problem cannot be resolved by the JTAC technician, a Return Materials Authorization
(RMA) is issued. This number is used to track the returned material at the factory and to return repaired or new components to the customer as needed.
NOTE: Do not return any component to Juniper Networks, Inc. unless you have first obtained an RMA number. Juniper Networks, Inc. reserves the right to refuse shipments that do not have an RMA. Refused shipments are returned to the customer by collect freight.
For more information about return and repair policies, see the customer support Web page at http://www.juniper.net/support/guidelines.html
.
Copyright © 2017, Juniper Networks, Inc.
527
MX960 3D Universal Edge Router Hardware Guide
For product problems or technical support issues, contact the Juniper Networks Technical
Assistance Center (JTAC) by using the Case Manager link at http://www.juniper.net/support/ or at 1-888-314-JTAC (within the United States) or
1-408-745-9500 (from outside the United States).
To return a hardware component:
1.
Determine the part number and serial number of the component.
2.
Obtain an RMA number from the Juniper Networks Technical Assistance Center (JTAC).
You can send e-mail or telephone as described above.
3.
Provide the following information in your e-mail message or during the telephone call:
• Part number and serial number of component
• Your name, organization name, telephone number, and fax number
• Description of the failure
4.
The support representative validates your request and issues an RMA number for return of the component.
5.
Pack the component for shipment.
Related
Documentation
•
Contacting Customer Support on page 505
•
Guidelines for Packing Hardware Components for Shipment on page 524
528 Copyright © 2017, Juniper Networks, Inc.
CHAPTER 35
Safety and Compliance Information
•
General Safety Guidelines and Warnings on page 529
•
Installation and Maintenance Safety Guidelines and Warnings on page 534
•
Radiation and Laser Warnings on page 541
•
Maintenance and Operational Safety Guidelines and Warnings on page 544
•
Electrical Safety Guidelines and Warnings on page 549
•
Agency Approvals and Compliance Statements on page 561
General Safety Guidelines and Warnings
•
General Safety Guidelines and Warnings on page 529
•
Definitions of Safety Warning Levels on page 530
•
Qualified Personnel Warning on page 532
•
Fire Safety Requirements on page 533
•
Warning Statement for Norway and Sweden on page 534
General Safety Guidelines and Warnings
The following guidelines help ensure your safety and protect the device from damage.
The list of guidelines might not address all potentially hazardous situations in your working environment, so be alert and exercise good judgment at all times.
• Perform only the procedures explicitly described in the hardware documentation for this device. Make sure that only authorized service personnel perform other system services.
• Keep the area around the device clear and free from dust before, during, and after installation.
• Keep tools away from areas where people could trip over them while walking.
• Do not wear loose clothing or jewelry, such as rings, bracelets, or chains, which could become caught in the device.
• Wear safety glasses if you are working under any conditions that could be hazardous to your eyes.
Copyright © 2017, Juniper Networks, Inc.
529
MX960 3D Universal Edge Router Hardware Guide
• Do not perform any actions that create a potential hazard to people or make the equipment unsafe.
• Never attempt to lift an object that is too heavy for one person to handle.
• Never install or manipulate wiring during electrical storms.
• Never install electrical jacks in wet locations unless the jacks are specifically designed for wet environments.
• Operate the device only when it is properly grounded.
• Ensure that the separate protective earthing terminal provided on this device is permanently connected to earth.
• Replace fuses only with fuses of the same type and rating.
• Do not open or remove chassis covers or sheet-metal parts unless instructions are provided in the hardware documentation for this device. Such an action could cause severe electrical shock.
• Do not push or force any objects through any opening in the chassis frame. Such an action could result in electrical shock or fire.
• Avoid spilling liquid onto the chassis or onto any device component. Such an action could cause electrical shock or damage the device.
• Avoid touching uninsulated electrical wires or terminals that have not been disconnected from their power source. Such an action could cause electrical shock.
• Always ensure that all modules, power supplies, and cover panels are fully inserted and that the installation screws are fully tightened.
Related
Documentation
•
AC Power Electrical Safety Guidelines on page 552
•
General Electrical Safety Guidelines and Warnings on page 550
•
Maintenance and Operational Safety Guidelines and Warnings on page 544
•
Installation Instructions Warning on page 534
•
Grounded Equipment Warning on page 540
Definitions of Safety Warning Levels
The documentation uses the following levels of safety warnings (there are two Warning formats):
NOTE: You might find this information helpful in a particular situation, or you might overlook this important information if it was not highlighted in a Note.
CAUTION: You need to observe the specified guidelines to prevent minor injury or discomfort to you or severe damage to the device.
530 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
Copyright © 2017, Juniper Networks, Inc.
WARNING: This symbol alerts you to the risk of personal injury from a laser.
WARNING: This symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen.
Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista.
Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant causer des blessures ou des dommages corporels.
Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents.
Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer
Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der
Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen
Stromkreisen verbundenen Gefahren und der Standardpraktiken zur
Vermeidung von Unfällen bewußt.
Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti.
Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker.
Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes.
¡Atención!
Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos
531
MX960 3D Universal Edge Router Hardware Guide que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes.
Varning!
Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
Installation Instructions Warning on page 534
•
Maintenance and Operational Safety Guidelines and Warnings on page 544
•
Grounded Equipment Warning on page 540
•
Laser and LED Safety Guidelines and Warnings on page 541
• Laser and LED Safety Guidelines and Warnings for the QFX Series
• Laser and LED Safety Guidelines and Warnings for the PTX Series
•
Warning Statement for Norway and Sweden on page 534
Qualified Personnel Warning
WARNING: Only trained and qualified personnel should install or replace the device.
Waarschuwing Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden.
Varoitus Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen.
Attention Tout installation ou remplacement de l'appareil doit être réalisé par du personnel qualifié et compétent.
Warnung Gerät nur von geschultem, qualifiziertem Personal installieren oder auswechseln lassen.
Avvertenza Solo personale addestrato e qualificato deve essere autorizzato ad installare o sostituire questo apparecchio.
Advarsel Kun kvalifisert personell med riktig opplæring bør montere eller bytte ut dette utstyret.
Aviso Este equipamento deverá ser instalado ou substituído apenas por pessoal devidamente treinado e qualificado.
532 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
¡Atención!
Estos equipos deben ser instalados y reemplazados exclusivamente por personal técnico adecuadamente preparado y capacitado.
Varning!
Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
•
AC Power Electrical Safety Guidelines on page 552
• DC Power Electrical Safety Guidelines for Switches
Fire Safety Requirements
In the event of a fire emergency, the safety of people is the primary concern. You should establish procedures for protecting people in the event of a fire emergency, provide safety training, and properly provision fire-control equipment and fire extinguishers.
In addition, you should establish procedures to protect your equipment in the event of a fire emergency. Juniper Networks products should be installed in an environment suitable for electronic equipment. We recommend that fire suppression equipment be available in the event of a fire in the vicinity of the equipment and that all local fire, safety, and electrical codes and ordinances be observed when you install and operate your equipment.
Fire Suppression
In the event of an electrical hazard or an electrical fire, you should first turn power off to the equipment at the source. Then use a Type C fire extinguisher, which uses noncorrosive fire retardants, to extinguish the fire.
Fire Suppression Equipment
Type C fire extinguishers, which use noncorrosive fire retardants such as carbon dioxide and Halotron™, are most effective for suppressing electrical fires. Type C fire extinguishers displace oxygen from the point of combustion to eliminate the fire. For extinguishing fire on or around equipment that draws air from the environment for cooling, you should use this type of inert oxygen displacement extinguisher instead of an extinguisher that leaves residues on equipment.
Do not use multipurpose Type ABC chemical fire extinguishers (dry chemical fire extinguishers). The primary ingredient in these fire extinguishers is monoammonium phosphate, which is very sticky and difficult to clean. In addition, in the presence of minute amounts of moisture, monoammonium phosphate can become highly corrosive and corrodes most metals.
Any equipment in a room in which a chemical fire extinguisher has been discharged is subject to premature failure and unreliable operation. The equipment is considered to be irreparably damaged.
Copyright © 2017, Juniper Networks, Inc.
533
MX960 3D Universal Edge Router Hardware Guide
NOTE: To keep warranties effective, do not use a dry chemical fire extinguisher to control a fire at or near a Juniper Networks device. If a dry chemical fire extinguisher is used, the unit is no longer eligible for coverage under a service agreement.
We recommend that you dispose of any irreparably damaged equipment in an environmentally responsible manner.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
•
Action to Take After an Electrical Accident on page 561
Warning Statement for Norway and Sweden
WARNING: The equipment must be connected to an earthed mains socket-outlet.
Advarsel Apparatet skal kobles til en jordet stikkontakt.
Varning!
Apparaten skall anslutas till jordat nätuttag.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
Installation and Maintenance Safety Guidelines and Warnings
•
Installation Instructions Warning on page 534
•
Chassis Lifting Guidelines on page 535
•
•
Rack-Mounting and Cabinet-Mounting Warnings on page 536
•
Grounded Equipment Warning on page 540
Installation Instructions Warning
WARNING: Read the installation instructions before you connect the device to a power source.
Waarschuwing Raadpleeg de installatie-aanwijzingen voordat u het systeem met de voeding verbindt.
Varoitus Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen.
534 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Warnung Lesen Sie die Installationsanweisungen, bevor Sie das System an die Stromquelle anschließen.
Avvertenza Consultare le istruzioni di installazione prima di collegare il sistema all'alimentatore.
Advarsel Les installasjonsinstruksjonene før systemet kobles til strømkilden.
Aviso Leia as instruções de instalação antes de ligar o sistema à sua fonte de energia.
¡Atención!
Ver las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Varning!
Läs installationsanvisningarna innan du kopplar systemet till dess strömförsörjningsenhet.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
Laser and LED Safety Guidelines and Warnings on page 541
•
Grounded Equipment Warning on page 540
Chassis Lifting Guidelines
• Before moving the device to a site, ensure that the site meets the power, environmental, and clearance requirements.
• Before lifting or moving the device, disconnect all external cables and wires.
• As when lifting any heavy object, ensure that most of the weight is borne by your legs rather than your back. Keep your knees bent and your back relatively straight. Do not twist your body as you lift. Balance the load evenly and be sure that your footing is firm.
• Use the following lifting guidelines to lift routing devices and components:
• Up to 39.7 lb (18 kg): One person.
• 39.7 lb (18 kg) to 70.5 lb (32 kg): Two or more people.
• 70.5 lb (32 kg) to 121.2 lb (55 kg): Three or more people.
• Above 121.2 lbs (55 kg): Material handling systems (such as levers, slings, lifts and so on) must be used. When this is not practical, specially trained persons or systems must be used (riggers or movers).
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
Installation Instructions Warning on page 534
Copyright © 2017, Juniper Networks, Inc.
535
MX960 3D Universal Edge Router Hardware Guide
Ramp Warning
WARNING: When installing the device, do not use a ramp inclined at more than 10 degrees.
Waarschuwing Gebruik een oprijplaat niet onder een hoek van meer dan 10 graden.
Varoitus Älä käytä sellaista kaltevaa pintaa, jonka kaltevuus ylittää 10 astetta.
Attention Ne pas utiliser une rampe dont l'inclinaison est supérieure à 10 degrés.
Warnung Keine Rampen mit einer Neigung von mehr als 10 Grad verwenden.
Avvertenza Non usare una rampa con pendenza superiore a 10 gradi.
Advarsel Bruk aldri en rampe som heller mer enn 10 grader.
Aviso Não utilize uma rampa com uma inclinação superior a 10 graus.
¡Atención!
No usar una rampa inclinada más de 10 grados
Varning!
Använd inte ramp med en lutning på mer än 10 grader.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
Installation Instructions Warning on page 534
•
Grounded Equipment Warning on page 540
Rack-Mounting and Cabinet-Mounting Warnings
Ensure that the rack or cabinet in which the device is installed is evenly and securely supported. Uneven mechanical loading could lead to a hazardous condition.
WARNING: To prevent bodily injury when mounting or servicing the device in a rack, take the following precautions to ensure that the system remains stable. The following directives help maintain your safety:
• The device must be installed in a rack that is secured to the building structure.
• The device should be mounted at the bottom of the rack if it is the only unit in the rack.
536 Copyright © 2017, Juniper Networks, Inc.
Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
• When mounting the device on a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing equipment, install the stabilizers before mounting or servicing the device in the rack.
Waarschuwing Om lichamelijk letsel te voorkomen wanneer u dit toestel in een rek monteert of het daar een servicebeurt geeft, moet u speciale voorzorgsmaatregelen nemen om ervoor te zorgen dat het toestel stabiel blijft. De onderstaande richtlijnen worden verstrekt om uw veiligheid te verzekeren:
• De Juniper Networks switch moet in een stellage worden geïnstalleerd die aan een bouwsel is verankerd.
• Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel het enige in het rek is.
• Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert, dient u het rek van onderen naar boven te laden met het zwaarste onderdeel onderaan in het rek.
• Als het rek voorzien is van stabiliseringshulpmiddelen, dient u de stabilisatoren te monteren voordat u het toestel in het rek monteert of het daar een servicebeurt geeft.
Varoitus Kun laite asetetaan telineeseen tai huolletaan sen ollessa telineessä, on noudatettava erityisiä varotoimia järjestelmän vakavuuden säilyttämiseksi, jotta vältytään loukkaantumiselta. Noudata seuraavia turvallisuusohjeita:
• Juniper Networks switch on asennettava telineeseen, joka on kiinnitetty rakennukseen.
• Jos telineessä ei ole muita laitteita, aseta laite telineen alaosaan.
• Jos laite asetetaan osaksi täytettyyn telineeseen, aloita kuormittaminen sen alaosasta kaikkein raskaimmalla esineellä ja siirry sitten sen yläosaan.
• Jos telinettä varten on vakaimet, asenna ne ennen laitteen asettamista telineeseen tai sen huoltamista siinä.
Attention Pour éviter toute blessure corporelle pendant les opérations de montage ou de réparation de cette unité en casier, il convient de prendre des précautions spéciales afin de maintenir la stabilité du système. Les directives ci-dessous sont destinées à assurer la protection du personnel:
• Le rack sur lequel est monté le Juniper Networks switch doit être fixé à la structure du bâtiment.
• Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas.
537
MX960 3D Universal Edge Router Hardware Guide
538
• Si cette unité est montée dans un casier partiellement rempli, charger le casier de bas en haut en plaçant l'élément le plus lourd dans le bas.
• Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs avant de monter ou de réparer l'unité en casier.
Warnung Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System stabil bleibt. Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen:
• Der Juniper Networks switch muß in einem Gestell installiert werden, das in der Gebäudestruktur verankert ist.
• Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell angebracht werden.
• Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das
Gestell von unten nach oben zu laden, wobei das schwerste Bauteil unten im Gestell anzubringen ist.
• Wird das Gestell mit Stabilisierungszubehör geliefert, sind zuerst die
Stabilisatoren zu installieren, bevor Sie die Einheit im Gestell anbringen oder sie warten.
Avvertenza Per evitare infortuni fisici durante il montaggio o la manutenzione di questa unità in un supporto, occorre osservare speciali precauzioni per garantire che il sistema rimanga stabile. Le seguenti direttive vengono fornite per garantire la sicurezza personale:
• Il Juniper Networks switch deve essere installato in un telaio, il quale deve essere fissato alla struttura dell'edificio.
• Questa unità deve venire montata sul fondo del supporto, se si tratta dell'unica unità da montare nel supporto.
• Quando questa unità viene montata in un supporto parzialmente pieno, caricare il supporto dal basso all'alto, con il componente più pesante sistemato sul fondo del supporto.
• Se il supporto è dotato di dispositivi stabilizzanti, installare tali dispositivi prima di montare o di procedere alla manutenzione dell'unità nel supporto.
Advarsel Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt. Følgende retningslinjer er gitt for å verne om sikkerheten:
• Juniper Networks switch må installeres i et stativ som er forankret til bygningsstrukturen.
• Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste enheten i kabinettet.
Copyright © 2017, Juniper Networks, Inc.
Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
• Ved montering av denne enheten i et kabinett som er delvis fylt, skal kabinettet lastes fra bunnen og opp med den tyngste komponenten nederst i kabinettet.
• Hvis kabinettet er utstyrt med stabiliseringsutstyr, skal stabilisatorene installeres før montering eller utføring av reparasjonsarbeid på enheten i kabinettet.
Aviso Para se prevenir contra danos corporais ao montar ou reparar esta unidade numa estante, deverá tomar precauções especiais para se certificar de que o sistema possui um suporte estável. As seguintes directrizes ajudá-lo-ão a efectuar o seu trabalho com segurança:
• O Juniper Networks switch deverá ser instalado numa prateleira fixa à estrutura do edificio.
• Esta unidade deverá ser montada na parte inferior da estante, caso seja esta a única unidade a ser montada.
• Ao montar esta unidade numa estante parcialmente ocupada, coloque os itens mais pesados na parte inferior da estante, arrumando-os de baixo para cima.
• Se a estante possuir um dispositivo de estabilização, instale-o antes de montar ou reparar a unidade.
¡Atención!
Para evitar lesiones durante el montaje de este equipo sobre un bastidor, o posteriormente durante su mantenimiento, se debe poner mucho cuidado en que el sistema quede bien estable. Para garantizar su seguridad, proceda según las siguientes instrucciones:
• El Juniper Networks switch debe instalarse en un bastidor fijado a la estructura del edificio.
• Colocar el equipo en la parte inferior del bastidor, cuando sea la única unidad en el mismo.
• Cuando este equipo se vaya a instalar en un bastidor parcialmente ocupado, comenzar la instalación desde la parte inferior hacia la superior colocando el equipo más pesado en la parte inferior.
• Si el bastidor dispone de dispositivos estabilizadores, instalar éstos antes de montar o proceder al mantenimiento del equipo instalado en el bastidor.
Varning!
För att undvika kroppsskada när du installerar eller utför underhållsarbete på denna enhet på en ställning måste du vidta särskilda försiktighetsåtgärder för att försäkra dig om att systemet står stadigt. Följande riktlinjer ges för att trygga din säkerhet:
539
MX960 3D Universal Edge Router Hardware Guide
• Juniper Networks switch måste installeras i en ställning som är förankrad i byggnadens struktur.
• Om denna enhet är den enda enheten på ställningen skall den installeras längst ned på ställningen.
• Om denna enhet installeras på en delvis fylld ställning skall ställningen fyllas nedifrån och upp, med de tyngsta enheterna längst ned på ställningen.
• Om ställningen är försedd med stabiliseringsdon skall dessa monteras fast innan enheten installeras eller underhålls på ställningen.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
Installation Instructions Warning on page 534
•
Grounded Equipment Warning on page 540
Grounded Equipment Warning
WARNING: The device is intended to be grounded. During normal use, ensure that you have connected earth ground to the chassis.
Waarschuwing Deze apparatuur hoort geaard te worden Zorg dat de host-computer tijdens normaal gebruik met aarde is verbonden.
Varoitus Tämä laitteisto on tarkoitettu maadoitettavaksi. Varmista, että isäntälaite on yhdistetty maahan normaalikäytön aikana.
Attention Cet équipement doit être relié à la terre. S'assurer que l'appareil hôte est relié à la terre lors de l'utilisation normale.
Warnung Dieses Gerät muß geerdet werden. Stellen Sie sicher, daß das
Host-Gerät während des normalen Betriebs an Erde gelegt ist.
Avvertenza Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia collegato alla massa di terra durante il normale utilizzo.
Advarsel Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk.
Aviso Este equipamento deverá estar ligado à terra. Certifique-se que o host se encontra ligado à terra durante a sua utilização normal.
¡Atención!
Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté conectado a tierra durante el uso normal.
Varning!
Denna utrustning är avsedd att jordas. Se till att värdenheten är jordad vid normal användning.
540 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
AC Power Electrical Safety Guidelines on page 552
• DC Power Electrical Safety Guidelines for Switches
Radiation and Laser Warnings
•
Laser and LED Safety Guidelines and Warnings on page 541
•
Radiation from Open Port Apertures Warning on page 543
Laser and LED Safety Guidelines and Warnings
Juniper Networks devices are equipped with laser transmitters, which are considered a
Class 1 Laser Product by the U.S. Food and Drug Administration and are evaluated as a
Class 1 Laser Product per EN 60825-1 requirements.
Observe the following guidelines and warnings:
•
General Laser Safety Guidelines on page 541
•
Class 1 Laser Product Warning on page 541
•
Class 1 LED Product Warning on page 542
•
Laser Beam Warning on page 542
General Laser Safety Guidelines
When working around ports that support optical transceivers, observe the following safety guidelines to prevent eye injury:
• Do not look into unterminated ports or at fibers that connect to unknown sources.
• Do not examine unterminated optical ports with optical instruments.
• Avoid direct exposure to the beam.
WARNING: Unterminated optical connectors can emit invisible laser radiation. The lens in the human eye focuses all the laser power on the retina, so focusing the eye directly on a laser source—even a low-power laser—could permanently damage the eye.
Class 1 Laser Product Warning
WARNING: Class 1 laser product.
Waarschuwing Klasse-1 laser produkt.
Varoitus Luokan 1 lasertuote.
Attention Produit laser de classe I.
Copyright © 2017, Juniper Networks, Inc.
541
MX960 3D Universal Edge Router Hardware Guide
542
Warnung Laserprodukt der Klasse 1.
Avvertenza Prodotto laser di Classe 1.
Advarsel Laserprodukt av klasse 1.
Aviso Produto laser de classe 1.
¡Atención!
Producto láser Clase I.
Varning!
Laserprodukt av klass 1.
Class 1 LED Product Warning
WARNING: Class 1 LED product.
Waarschuwing Klasse 1 LED-product.
Varoitus Luokan 1 valodiodituote.
Attention Alarme de produit LED Class I.
Warnung Class 1 LED-Produktwarnung.
Avvertenza Avvertenza prodotto LED di Classe 1.
Advarsel LED-produkt i klasse 1.
Aviso Produto de classe 1 com LED.
¡Atención!
Aviso sobre producto LED de Clase 1.
Varning!
Lysdiodprodukt av klass 1.
Laser Beam Warning
WARNING: Do not stare into the laser beam or view it directly with optical instruments.
Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten.
Varoitus Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla.
Attention Ne pas fixer le faisceau des yeux, ni l'observer directement à l'aide d'instruments optiques.
Warnung Nicht direkt in den Strahl blicken und ihn nicht direkt mit optischen
Geräten prüfen.
Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
Avvertenza Non fissare il raggio con gli occhi né usare strumenti ottici per osservarlo direttamente.
Advarsel Stirr eller se ikke direkte p strlen med optiske instrumenter.
Aviso Não olhe fixamente para o raio, nem olhe para ele directamente com instrumentos ópticos.
¡Atención!
No mirar fijamente el haz ni observarlo directamente con instrumentos ópticos.
Varning!
Rikta inte blicken in mot strålen och titta inte direkt på den genom optiska instrument.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
Radiation from Open Port Apertures Warning on page 543
•
Installation Instructions Warning on page 534
•
Grounded Equipment Warning on page 540
Radiation from Open Port Apertures Warning
WARNING: Because invisible radiation might be emitted from the aperture of the port when no fiber cable is connected, avoid exposure to radiation and do not stare into open apertures.
Waarschuwing Aangezien onzichtbare straling vanuit de opening van de poort kan komen als er geen fiberkabel aangesloten is, dient blootstelling aan straling en het kijken in open openingen vermeden te worden.
Varoitus Koska portin aukosta voi emittoitua näkymätöntä säteilyä, kun kuitukaapelia ei ole kytkettynä, vältä säteilylle altistumista äläkä katso avoimiin aukkoihin.
Attention Des radiations invisibles à l'il nu pouvant traverser l'ouverture du port lorsqu'aucun câble en fibre optique n'y est connecté, il est recommandé de ne pas regarder fixement l'intérieur de ces ouvertures.
Warnung Aus der Port-Öffnung können unsichtbare Strahlen emittieren, wenn kein Glasfaserkabel angeschlossen ist. Vermeiden Sie es, sich den
Strahlungen auszusetzen, und starren Sie nicht in die Öffnungen!
Avvertenza Quando i cavi in fibra non sono inseriti, radiazioni invisibili possono essere emesse attraverso l'apertura della porta. Evitate di esporvi alle radiazioni e non guardate direttamente nelle aperture.
Copyright © 2017, Juniper Networks, Inc.
543
MX960 3D Universal Edge Router Hardware Guide
Advarsel Unngå utsettelse for stråling, og stirr ikke inn i åpninger som er åpne, fordi usynlig stråling kan emiteres fra portens åpning når det ikke er tilkoblet en fiberkabel.
Aviso Dada a possibilidade de emissão de radiação invisível através do orifício da via de acesso, quando esta não tiver nenhum cabo de fibra conectado, deverá evitar a exposição à radiação e não deverá olhar fixamente para orifícios que se encontrarem a descoberto.
¡Atención!
Debido a que la apertura del puerto puede emitir radiación invisible cuando no existe un cable de fibra conectado, evite mirar directamente a las aperturas para no exponerse a la radiación.
Varning!
Osynlig strålning kan avges från en portöppning utan ansluten fiberkabel och du bör därför undvika att bli utsatt för strålning genom att inte stirra in i oskyddade öppningar.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
Laser and LED Safety Guidelines and Warnings on page 541
•
Installation Instructions Warning on page 534
•
Grounded Equipment Warning on page 540
Maintenance and Operational Safety Guidelines and Warnings
•
Maintenance and Operational Safety Guidelines and Warnings on page 544
Maintenance and Operational Safety Guidelines and Warnings
While performing the maintenance activities for devices, observe the following guidelines and warnings:
•
Battery Handling Warning on page 544
•
Jewelry Removal Warning on page 545
•
Lightning Activity Warning on page 547
•
Operating Temperature Warning on page 547
•
Product Disposal Warning on page 548
Battery Handling Warning
WARNING: Replacing a battery incorrectly might result in an explosion.
Replace a battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
544 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
Waarschuwing Er is ontploffingsgevaar als de batterij verkeerd vervangen wordt. Vervang de batterij slechts met hetzelfde of een equivalent type dat door de fabrikant aanbevolen is. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften weggeworpen te worden.
Varoitus Räjähdyksen vaara, jos akku on vaihdettu väärään akkuun. Käytä vaihtamiseen ainoastaan saman- tai vastaavantyyppistä akkua, joka on valmistajan suosittelema. Hävitä käytetyt akut valmistajan ohjeiden mukaan.
Attention Danger d'explosion si la pile n'est pas remplacée correctement.
Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant.
Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr.
Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den
Anweisungen des Herstellers.
Advarsel Det kan være fare for eksplosjon hvis batteriet skiftes på feil måte.
Skift kun med samme eller tilsvarende type som er anbefalt av produsenten.
Kasser brukte batterier i henhold til produsentens instruksjoner.
Avvertenza Pericolo di esplosione se la batteria non è installata correttamente. Sostituire solo con una di tipo uguale o equivalente, consigliata dal produttore. Eliminare le batterie usate secondo le istruzioni del produttore.
Aviso Existe perigo de explosão se a bateria for substituída incorrectamente.
Substitua a bateria por uma bateria igual ou de um tipo equivalente recomendado pelo fabricante. Destrua as baterias usadas conforme as instruções do fabricante.
¡Atención!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante. Desechar las baterías gastadas según las instrucciones del fabricante.
Varning!
Explosionsfara vid felaktigt batteribyte. Ersätt endast batteriet med samma batterityp som rekommenderas av tillverkaren eller motsvarande.
Följ tillverkarens anvisningar vid kassering av använda batterier.
Jewelry Removal Warning
WARNING: Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal objects heat up when connected to power and ground and can cause serious burns or can be welded to the terminals.
Copyright © 2017, Juniper Networks, Inc.
545
MX960 3D Universal Edge Router Hardware Guide
546
Waarschuwing Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen. Metalen voorwerpen worden warm wanneer ze met stroom en aarde zijn verbonden, en kunnen ernstige brandwonden veroorzaken of het metalen voorwerp aan de aansluitklemmen lassen.
Varoitus Ennen kuin työskentelet voimavirtajohtoihin kytkettyjen laitteiden parissa, ota pois kaikki korut (sormukset, kaulakorut ja kellot mukaan lukien).
Metalliesineet kuumenevat, kun ne ovat yhteydessä sähkövirran ja maan kanssa, ja ne voivat aiheuttaa vakavia palovammoja tai hitsata metalliesineet kiinni liitäntänapoihin.
Attention Avant d'accéder à cet équipement connecté aux lignes électriques,
ôter tout bijou (anneaux, colliers et montres compris). Lorsqu'ils sont branchés
à l'alimentation et reliés à la terre, les objets métalliques chauffent, ce qui peut provoquer des blessures graves ou souder l'objet métallique aux bornes.
Warnung Vor der Arbeit an Geräten, die an das Netz angeschlossen sind, jeglichen Schmuck (einschließlich Ringe, Ketten und Uhren) abnehmen.
Metallgegenstände erhitzen sich, wenn sie an das Netz und die Erde angeschlossen werden, und können schwere Verbrennungen verursachen oder an die Anschlußklemmen angeschweißt werden.
Avvertenza Prima di intervenire su apparecchiature collegate alle linee di alimentazione, togliersi qualsiasi monile (inclusi anelli, collane, braccialetti ed orologi). Gli oggetti metallici si riscaldano quando sono collegati tra punti di alimentazione e massa: possono causare ustioni gravi oppure il metallo può saldarsi ai terminali.
Advarsel Fjern alle smykker (inkludert ringer, halskjeder og klokker) før du skal arbeide på utstyr som er koblet til kraftledninger. Metallgjenstander som er koblet til kraftledninger og jord blir svært varme og kan forårsake alvorlige brannskader eller smelte fast til polene.
Aviso Antes de trabalhar em equipamento que esteja ligado a linhas de corrente, retire todas as jóias que estiver a usar (incluindo anéis, fios e relógios). Os objectos metálicos aquecerão em contacto com a corrente e em contacto com a ligação à terra, podendo causar queimaduras graves ou ficarem soldados aos terminais.
¡Atención!
Antes de operar sobre equipos conectados a líneas de alimentación, quitarse las joyas (incluidos anillos, collares y relojes). Los objetos de metal se calientan cuando se conectan a la alimentación y a tierra, lo que puede ocasionar quemaduras graves o que los objetos metálicos queden soldados a los bornes.
Varning!
Tag av alla smycken (inklusive ringar, halsband och armbandsur) innan du arbetar på utrustning som är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och kan förorsaka
Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information allvarliga brännskador; metallobjekt kan också sammansvetsas med kontakterna.
Lightning Activity Warning
WARNING: Do not work on the system or connect or disconnect cables during periods of lightning activity.
Waarschuwing Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen.
Varoitus Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla.
Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.
Warnung Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw. trennen Sie keine ab, wenn es gewittert.
Avvertenza Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini.
Advarsel Utfør aldri arbeid på systemet, eller koble kabler til eller fra systemet når det tordner eller lyner.
Aviso Não trabalhe no sistema ou ligue e desligue cabos durante períodos de mau tempo (trovoada).
¡Atención!
No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas eléctricas en la atmósfera.
Varning!
Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar.
Operating Temperature Warning
WARNING: To prevent the device from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature. To prevent airflow restriction, allow at least 6 in. (15.2 cm) of clearance around the ventilation openings.
Waarschuwing Om te voorkomen dat welke switch van de Juniper Networks router dan ook oververhit raakt, dient u deze niet te bedienen op een plaats waar de maximale aanbevolen omgevingstemperatuur van 40° C wordt overschreden. Om te voorkomen dat de luchtstroom wordt beperkt, dient er minstens 15,2 cm speling rond de ventilatie-openingen te zijn.
Copyright © 2017, Juniper Networks, Inc.
547
MX960 3D Universal Edge Router Hardware Guide
548
Varoitus Ettei Juniper Networks switch-sarjan reititin ylikuumentuisi, sitä ei saa käyttää tilassa, jonka lämpötila ylittää korkeimman suositellun ympäristölämpötilan 40° C. Ettei ilmanvaihto estyisi, tuuletusaukkojen ympärille on jätettävä ainakin 15,2 cm tilaa.
Attention Pour éviter toute surchauffe des routeurs de la gamme Juniper
Networks switch, ne l'utilisez pas dans une zone où la température ambiante est supérieure à 40° C. Pour permettre un flot d'air constant, dégagez un espace d'au moins 15,2 cm autour des ouvertures de ventilations.
Warnung Um einen Router der switch vor Überhitzung zu schützen, darf dieser nicht in einer Gegend betrieben werden, in der die Umgebungstemperatur das empfohlene Maximum von 40° C überschreitet. Um Lüftungsverschluß zu verhindern, achten Sie darauf, daß mindestens 15,2 cm lichter Raum um die Lüftungsöffnungen herum frei bleibt.
Avvertenza Per evitare il surriscaldamento dei switch, non adoperateli in un locale che ecceda la temperatura ambientale massima di 40° C. Per evitare che la circolazione dell'aria sia impedita, lasciate uno spazio di almeno 15.2 cm di fronte alle aperture delle ventole.
Advarsel Unngå overoppheting av eventuelle rutere i Juniper Networks switch
Disse skal ikke brukes på steder der den anbefalte maksimale omgivelsestemperaturen overstiger 40° C (104° F). Sørg for at klaringen rundt lufteåpningene er minst 15,2 cm (6 tommer) for å forhindre nedsatt luftsirkulasjon.
Aviso Para evitar o sobreaquecimento do encaminhador Juniper Networks switch, não utilize este equipamento numa área que exceda a temperatura máxima recomendada de 40° C. Para evitar a restrição à circulação de ar, deixe pelo menos um espaço de 15,2 cm à volta das aberturas de ventilação.
¡Atención!
Para impedir que un encaminador de la serie Juniper Networks switch se recaliente, no lo haga funcionar en un área en la que se supere la temperatura ambiente máxima recomendada de 40° C. Para impedir la restricción de la entrada de aire, deje un espacio mínimo de 15,2 cm alrededor de las aperturas para ventilación.
Varning!
Förhindra att en Juniper Networks switch överhettas genom att inte använda den i ett område där den maximalt rekommenderade omgivningstemperaturen på 40° C överskrids. Förhindra att luftcirkulationen inskränks genom att se till att det finns fritt utrymme på minst 15,2 cm omkring ventilationsöppningarna.
Product Disposal Warning
WARNING: Disposal of this device must be handled according to all national laws and regulations.
Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt.
Varoitus Tämän tuotteen lopullisesta hävittämisestä tulee huolehtia kaikkia valtakunnallisia lakeja ja säännöksiä noudattaen.
Attention La mise au rebut définitive de ce produit doit être effectuée conformément à toutes les lois et réglementations en vigueur.
Warnung Dieses Produkt muß den geltenden Gesetzen und Vorschriften entsprechend entsorgt werden.
Avvertenza L'eliminazione finale di questo prodotto deve essere eseguita osservando le normative italiane vigenti in materia
Advarsel Endelig disponering av dette produktet må skje i henhold til nasjonale lover og forskrifter.
Aviso A descartagem final deste produto deverá ser efectuada de acordo com os regulamentos e a legislação nacional.
¡Atención!
El desecho final de este producto debe realizarse según todas las leyes y regulaciones nacionales
Varning!
Slutlig kassering av denna produkt bör skötas i enlighet med landets alla lagar och föreskrifter.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
•
AC Power Electrical Safety Guidelines on page 552
• DC Power Electrical Safety Guidelines for Switches
•
Laser and LED Safety Guidelines and Warnings on page 541
•
Installation Instructions Warning on page 534
•
Grounded Equipment Warning on page 540
Electrical Safety Guidelines and Warnings
•
General Electrical Safety Guidelines and Warnings on page 550
•
Prevention of Electrostatic Discharge Damage on page 551
•
AC Power Electrical Safety Guidelines on page 552
•
AC Power Disconnection Warning on page 553
•
DC Power Copper Conductors Warning on page 554
•
DC Power Disconnection Warning on page 554
Copyright © 2017, Juniper Networks, Inc.
549
MX960 3D Universal Edge Router Hardware Guide
•
DC Power Grounding Requirements and Warning on page 556
•
DC Power Wiring Sequence Warning on page 557
•
DC Power Wiring Terminations Warning on page 559
•
Midplane Energy Hazard Warning on page 560
•
Multiple Power Supplies Disconnection Warning on page 560
•
Action to Take After an Electrical Accident on page 561
General Electrical Safety Guidelines and Warnings
WARNING: Certain ports on the device are designed for use as intrabuilding
(within-the-building) interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE) and require isolation from the exposed outside plant (OSP) cabling. To comply with NEBS requirements and protect against lightning surges and commercial power disturbances, the intrabuilding ports must not be metallically connected to interfaces that connect to the OSP or its wiring.
The intrabuilding ports on the device are suitable for connection to intrabuilding or unexposed wiring or cabling only. The addition of primary protectors is not sufficient protection for connecting these interfaces metallically to OSP wiring.
CAUTION: Before removing or installing components of a device, attach an electrostatic discharge (ESD) grounding strap to an ESD point and place the other end of the strap around your bare wrist. Failure to use an ESD grounding strap could result in damage to the device.
• Install the device in compliance with the following local, national, and international electrical codes:
• United States—National Fire Protection Association (NFPA 70), United States
National Electrical Code.
• Other countries—International Electromechanical Commission (IEC) 60364, Part 1 through Part 7.
• Evaluated to the TN power system.
• Canada—Canadian Electrical Code, Part 1, CSA C22.1.
• Locate the emergency power-off switch for the room in which you are working so that if an electrical accident occurs, you can quickly turn off the power.
• Make sure that grounding surfaces are cleaned and brought to a bright finish before grounding connections are made.
• Do not work alone if potentially hazardous conditions exist anywhere in your workspace.
• Never assume that power is disconnected from a circuit. Always check the circuit before starting to work.
550 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
• Carefully look for possible hazards in your work area, such as moist floors, ungrounded power extension cords, and missing safety grounds.
• Operate the device within marked electrical ratings and product usage instructions.
• To ensure that the device and peripheral equipment function safely and correctly, use the cables and connectors specified for the attached peripheral equipment, and make certain they are in good condition.
You can remove and replace many device components without powering off or disconnecting power to the device, as detailed elsewhere in the hardware documentation for this device. Never install equipment that appears to be damaged.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
AC Power Electrical Safety Guidelines on page 552
• DC Power Electrical Safety Guidelines for Switches
Prevention of Electrostatic Discharge Damage
Device components that are shipped in antistatic bags are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets. Observe the following guidelines to minimize the potential for electrostatic discharge (ESD) damage, which can cause intermittent or complete component failures:
• Always use an ESD grounding strap when you are handling components that are subject to ESD damage, and make sure that it is in direct contact with your skin.
If a grounding strap is not available, hold the component in its antistatic bag (see
) in one hand and touch the exposed, bare metal of the device with the other hand immediately before inserting the component into the device.
WARNING: For safety, periodically check the resistance value of the ESD grounding strap. The measurement must be in the range 1 through
10 Mohms.
• When handling any component that is subject to ESD damage and that is removed from the device, make sure the equipment end of your ESD grounding strap is attached to the ESD point on the chassis.
If no grounding strap is available, touch the exposed, bare metal of the device to ground yourself before handling the component.
• Avoid contact between the component that is subject to ESD damage and your clothing.
ESD voltages emitted from clothing can damage components.
• When removing or installing a component that is subject to ESD damage, always place it component-side up on an antistatic surface, in an antistatic card rack, or in an
Copyright © 2017, Juniper Networks, Inc.
551
MX960 3D Universal Edge Router Hardware Guide antistatic bag (see
). If you are returning a component, place it in an antistatic bag before packing it.
Figure 205: Placing a Component into an Antistatic Bag
CAUTION
ELECTROSTATIC
SENSITIVE
DEVICES
DO NOT OPEN OR HANDLE
EXCEPT AT A
STATIC-FREE WORKSTATION
6xGE
SFP
0
1
2
3
4
5
CAUTION: ANSI/TIA/EIA-568 cables such as Category 5e and Category 6 can get electrostatically charged. To dissipate this charge, always ground the cables to a suitable and safe earth ground before connecting them to the system.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
AC Power Electrical Safety Guidelines
CAUTION: For devices with AC power supplies, an external surge protective device (SPD) must be used at the AC power source.
The following electrical safety guidelines apply to AC-powered devices:
• Note the following warnings printed on the device:
“ CAUTION: THIS UNIT HAS MORE THAN ONE POWER SUPPLY CORD. DISCONNECT
ALL POWER SUPPLY CORDS BEFORE SERVICING TO AVOID ELECTRIC SHOCK.”
“ ATTENTION: CET APPAREIL COMPORTE PLUS D'UN CORDON D'ALIMENTATION.
AFIN DE PRÉVENIR LES CHOCS ÉLECTRIQUES, DÉBRANCHER TOUT CORDON
D'ALIMENTATION AVANT DE FAIRE LE DÉPANNAGE.”
• AC-powered devices are shipped with a three-wire electrical cord with a grounding-type plug that fits only a grounding-type power outlet. Do not circumvent this safety feature.
Equipment grounding must comply with local and national electrical codes.
• You must provide an external certified circuit breaker rated minimum 20 A in the building installation.
552 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
• The power cord serves as the main disconnecting device for the AC-powered device.
The socket outlet must be near the AC-powered device and be easily accessible.
• For devices that have more than one power supply connection, you must ensure that all power connections are fully disconnected so that power to the device is completely removed to prevent electric shock. To disconnect power, unplug all power cords (one for each power supply).
Power Cable Warning (Japanese)
WARNING: The attached power cable is only for this product. Do not use the cable for another product.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
•
Multiple Power Supplies Disconnection Warning on page 560
AC Power Disconnection Warning
WARNING: Before working on the device or near power supplies, unplug all the power cords from an AC-powered device.
Waarschuwing Voordat u aan een frame of in de nabijheid van voedingen werkt, dient u bij wisselstroom toestellen de stekker van het netsnoer uit het stopcontact te halen.
Varoitus Kytke irti vaihtovirtalaitteiden virtajohto, ennen kuin teet mitään asennuspohjalle tai työskentelet virtalähteiden läheisyydessä.
Attention Avant de travailler sur un châssis ou à proximité d'une alimentation
électrique, débrancher le cordon d'alimentation des unités en courant alternatif.
Warnung Bevor Sie an einem Chassis oder in der Nähe von Netzgeräten arbeiten, ziehen Sie bei Wechselstromeinheiten das Netzkabel ab bzw.
Avvertenza Prima di lavorare su un telaio o intorno ad alimentatori, scollegare il cavo di alimentazione sulle unità CA.
Copyright © 2017, Juniper Networks, Inc.
553
MX960 3D Universal Edge Router Hardware Guide
Advarsel Før det utføres arbeid på kabinettet eller det arbeides i nærheten av strømforsyningsenheter, skal strømledningen trekkes ut på vekselstrømsenheter.
Aviso Antes de trabalhar num chassis, ou antes de trabalhar perto de unidades de fornecimento de energia, desligue o cabo de alimentação nas unidades de corrente alternada.
¡Atención!
Antes de manipular el chasis de un equipo o trabajar cerca de una fuente de alimentación, desenchufar el cable de alimentación en los equipos de corriente alterna (CA).
Varning!
Innan du arbetar med ett chassi eller nära strömförsörjningsenheter skall du för växelströmsenheter dra ur nätsladden.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
•
AC Power Electrical Safety Guidelines on page 552
DC Power Copper Conductors Warning
WARNING: Use copper conductors only.
Waarschuwing Gebruik alleen koperen geleiders.
Varoitus Käytä vain kuparijohtimia.
Attention Utilisez uniquement des conducteurs en cuivre.
Warnung Verwenden Sie ausschließlich Kupferleiter.
Avvertenza Usate unicamente dei conduttori di rame.
Advarsel Bruk bare kobberledninger.
Aviso Utilize apenas fios condutores de cobre.
¡Atención!
Emplee sólo conductores de cobre.
Varning!
Använd endast ledare av koppar.
DC Power Disconnection Warning
WARNING: Before performing any of the DC power procedures, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the
554 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
Copyright © 2017, Juniper Networks, Inc.
circuit breaker to the OFF position, and tape the device handle of the circuit breaker in the OFF position.
Waarschuwing Voordat u een van de onderstaande procedures uitvoert, dient u te controleren of de stroom naar het gelijkstroom circuit uitgeschakeld is. Om u ervan te verzekeren dat alle stroom UIT is geschakeld, kiest u op het schakelbord de stroomverbreker die het gelijkstroom circuit bedient, draait de stroomverbreker naar de UIT positie en plakt de schakelaarhendel van de stroomverbreker met plakband in de UIT positie vast.
Varoitus Varmista, että tasavirtapiirissä ei ole virtaa ennen seuraavien toimenpiteiden suorittamista. Varmistaaksesi, että virta on KATKAISTU täysin, paikanna tasavirrasta huolehtivassa kojetaulussa sijaitseva suojakytkin, käännä suojakytkin KATKAISTU-asentoon ja teippaa suojakytkimen varsi niin, että se pysyy KATKAISTU-asennossa.
Attention Avant de pratiquer l'une quelconque des procédures ci-dessous, vérifier que le circuit en courant continu n'est plus sous tension. Pour en être sûr, localiser le disjoncteur situé sur le panneau de service du circuit en courant continu, placer le disjoncteur en position fermée (OFF) et, à l'aide d'un ruban adhésif, bloquer la poignée du disjoncteur en position OFF.
Warnung Vor Ausführung der folgenden Vorgänge ist sicherzustellen, daß die Gleichstromschaltung keinen Strom erhält. Um sicherzustellen, daß sämtlicher Strom abgestellt ist, machen Sie auf der Schalttafel den
Unterbrecher für die Gleichstromschaltung ausfindig, stellen Sie den
Unterbrecher auf AUS, und kleben Sie den Schaltergriff des Unterbrechers mit Klebeband in der AUS-Stellung fest.
Avvertenza Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC non sia alimentato. Per verificare che tutta l'alimentazione sia scollegata (OFF), individuare l'interruttore automatico sul quadro strumenti che alimenta il circuito CC, mettere l'interruttore in posizione OFF e fissarlo con nastro adesivo in tale posizione.
Advarsel Før noen av disse prosedyrene utføres, kontroller at strømmen er frakoblet likestrømkretsen. Sørg for at all strøm er slått AV. Dette gjøres ved
å lokalisere strømbryteren på brytertavlen som betjener likestrømkretsen, slå strømbryteren AV og teipe bryterhåndtaket på strømbryteren i AV-stilling.
Aviso Antes de executar um dos seguintes procedimentos, certifique-se que desligou a fonte de alimentação de energia do circuito de corrente contínua.
Para se assegurar que toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente contínua e coloque-o na posição OFF
(Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora.
¡Atención!
Antes de proceder con los siguientes pasos, comprobar que la alimentación del circuito de corriente continua (CC) esté cortada (OFF). Para asegurarse de que toda la alimentación esté cortada (OFF), localizar el
555
MX960 3D Universal Edge Router Hardware Guide interruptor automático en el panel que alimenta al circuito de corriente continua, cambiar el interruptor automático a la posición de Apagado (OFF), y sujetar con cinta la palanca del interruptor automático en posición de
Apagado (OFF).
Varning!
Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare i FRÅN-läget.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
• DC Power Electrical Safety Guidelines for Switches
•
DC Power Grounding Requirements and Warning on page 556
•
DC Power Wiring Sequence Warning on page 557
•
DC Power Wiring Terminations Warning on page 559
DC Power Grounding Requirements and Warning
An insulated grounding conductor that is identical in size to the grounded and ungrounded branch circuit supply conductors but is identifiable by green and yellow stripes is installed as part of the branch circuit that supplies the device. The grounding conductor is a separately derived system at the supply transformer or motor generator set.
WARNING: When you install the device, the ground connection must always be made first and disconnected last.
Waarschuwing Bij de installatie van het toestel moet de aardverbinding altijd het eerste worden gemaakt en het laatste worden losgemaakt.
Varoitus Laitetta asennettaessa on maahan yhdistäminen aina tehtävä ensiksi ja maadoituksen irti kytkeminen viimeiseksi.
Attention Lors de l'installation de l'appareil, la mise à la terre doit toujours
être connectée en premier et déconnectée en dernier.
Warnung Der Erdanschluß muß bei der Installation der Einheit immer zuerst hergestellt und zuletzt abgetrennt werden.
Avvertenza In fase di installazione dell'unità, eseguire sempre per primo il collegamento a massa e disconnetterlo per ultimo.
Advarsel Når enheten installeres, må jordledningen alltid tilkobles først og frakobles sist.
556 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
Aviso Ao instalar a unidade, a ligação à terra deverá ser sempre a primeira a ser ligada, e a última a ser desligada.
¡Atención!
Al instalar el equipo, conectar la tierra la primera y desconectarla la última.
Varning!
Vid installation av enheten måste jordledningen alltid anslutas först och kopplas bort sist.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
• DC Power Electrical Safety Guidelines for Switches
•
DC Power Disconnection Warning on page 554
•
DC Power Wiring Sequence Warning on page 557
•
DC Power Wiring Terminations Warning on page 559
DC Power Wiring Sequence Warning
WARNING: Wire the DC power supply using the appropriate lugs. When connecting power, the proper wiring sequence is ground to ground, +RTN to
+RTN, then –48 V to –48 V. When disconnecting power, the proper wiring sequence is –48 V to –48 V, +RTN to +RTN, then ground to ground. Note that the ground wire must always be connected first and disconnected last.
Waarschuwing De juiste bedradingsvolgorde verbonden is aarde naar aarde,
+RTN naar +RTN, en –48 V naar – 48 V. De juiste bedradingsvolgorde losgemaakt is en –48 naar –48 V, +RTN naar +RTN, aarde naar aarde.
Varoitus Oikea yhdistettava kytkentajarjestys on maajohto maajohtoon,
+RTN varten +RTN, –48 V varten – 48 V. Oikea irrotettava kytkentajarjestys on –48 V varten – 48 V, +RTN varten +RTN, maajohto maajohtoon.
Attention Câblez l'approvisionnement d'alimentation CC En utilisant les crochets appropriés à l'extrémité de câblage. En reliant la puissance, l'ordre approprié de câblage est rectifié pour rectifier, +RTN à +RTN, puis –48 V à
–48 V. En débranchant la puissance, l'ordre approprié de câblage est –48 V
à –48 V, +RTN à +RTN, a alors rectifié pour rectifier. Notez que le fil de masse devrait toujours être relié d'abord et débranché pour la dernière fois. Notez que le fil de masse devrait toujours être relié d'abord et débranché pour la dernière fois.
Warnung Die Stromzufuhr ist nur mit geeigneten Ringösen an das DC Netzteil anzuschliessen. Die richtige Anschlusssequenz ist: Erdanschluss zu
Erdanschluss, +RTN zu +RTN und dann -48V zu -48V. Die richtige Sequenz
Copyright © 2017, Juniper Networks, Inc.
557
MX960 3D Universal Edge Router Hardware Guide zum Abtrennen der Stromversorgung ist -48V zu -48V, +RTN zu +RTN und dann Erdanschluss zu Erdanschluss. Es ist zu beachten dass der Erdanschluss immer zuerst angeschlossen und als letztes abgetrennt wird.
Avvertenza Mostra la morsettiera dell alimentatore CC. Cablare l'alimentatore
CC usando i connettori adatti all'estremità del cablaggio, come illustrato. La corretta sequenza di cablaggio è da massa a massa, da positivo a positivo
(da linea ad L) e da negativo a negativo (da neutro a N). Tenere presente che il filo di massa deve sempre venire collegato per primo e scollegato per ultimo.
Advarsel Riktig tilkoples tilkoplingssekvens er jord til jord, +RTN til +RTN,
–48 V til – 48 V. Riktig frakoples tilkoplingssekvens er –48 V til – 48 V, +RTN til +RTN, jord til jord.
Aviso Ate con alambre la fuente de potencia cc Usando los terminales apropiados en el extremo del cableado. Al conectar potencia, la secuencia apropiada del cableado se muele para moler, +RTN a +RTN, entonces –48 V a –48 V. Al desconectar potencia, la secuencia apropiada del cableado es
–48 V a –48 V, +RTN a +RTN, entonces molió para moler. Observe que el alambre de tierra se debe conectar siempre primero y desconectar por último.
Observe que el alambre de tierra se debe conectar siempre primero y desconectar por último.
¡Atención!
Wire a fonte de alimentação de DC Usando os talões apropriados na extremidade da fiação. Ao conectar a potência, a seqüência apropriada da fiação é moída para moer, +RTN a +RTN, então –48 V a –48 V. Ao desconectar a potência, a seqüência apropriada da fiação é –48 V a –48 V,
+RTN a +RTN, moeu então para moer. Anote que o fio à terra deve sempre ser conectado primeiramente e desconectado por último. Anote que o fio à terra deve sempre ser conectado primeiramente e desconectado por último.
Varning!
Korrekt kopplingssekvens ar jord till jord, +RTN till +RTN, –48 V till
–48 V. Korrekt kopplas kopplingssekvens ar –48 V till –48 V, +RTN till +RTN, jord till jord.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
• DC Power Electrical Safety Guidelines for Switches
•
DC Power Disconnection Warning on page 554
•
DC Power Grounding Requirements and Warning on page 556
•
DC Power Wiring Terminations Warning on page 559
558 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
DC Power Wiring Terminations Warning
WARNING: When stranded wiring is required, use approved wiring terminations, such as closed-loop or spade-type with upturned lugs. These terminations must be the appropriate size for the wires and must clamp both the insulation and conductor.
Waarschuwing Wanneer geslagen bedrading vereist is, dient u bedrading te gebruiken die voorzien is van goedgekeurde aansluitingspunten, zoals het gesloten-lus type of het grijperschop type waarbij de aansluitpunten omhoog wijzen. Deze aansluitpunten dienen de juiste maat voor de draden te hebben en dienen zowel de isolatie als de geleider vast te klemmen.
Varoitus Jos säikeellinen johdin on tarpeen, käytä hyväksyttyä johdinliitäntää, esimerkiksi suljettua silmukkaa tai kourumaista liitäntää, jossa on ylöspäin käännetyt kiinnityskorvat. Tällaisten liitäntöjen tulee olla kooltaan johtimiin sopivia ja niiden tulee puristaa yhteen sekä eristeen että johdinosan.
Attention Quand des fils torsadés sont nécessaires, utiliser des douilles terminales homologuées telles que celles à circuit fermé ou du type à plage ouverte avec cosses rebroussées. Ces douilles terminales doivent être de la taille qui convient aux fils et doivent être refermées sur la gaine isolante et sur le conducteur.
Warnung Wenn Litzenverdrahtung erforderlich ist, sind zugelassene
Verdrahtungsabschlüsse, z.B. für einen geschlossenen Regelkreis oder gabelförmig, mit nach oben gerichteten Kabelschuhen zu verwenden. Diese
Abschlüsse sollten die angemessene Größe für die Drähte haben und sowohl die Isolierung als auch den Leiter festklemmen.
Avvertenza Quando occorre usare trecce, usare connettori omologati, come quelli a occhiello o a forcella con linguette rivolte verso l'alto. I connettori devono avere la misura adatta per il cablaggio e devono serrare sia l'isolante che il conduttore.
Advarsel Hvis det er nødvendig med flertrådede ledninger, brukes godkjente ledningsavslutninger, som for eksempel lukket sløyfe eller spadetype med oppoverbøyde kabelsko. Disse avslutningene skal ha riktig størrelse i forhold til ledningene, og skal klemme sammen både isolasjonen og lederen.
Aviso Quando forem requeridas montagens de instalação eléctrica de cabo torcido, use terminações de cabo aprovadas, tais como, terminações de cabo em circuito fechado e planas com terminais de orelha voltados para cima.
Estas terminações de cabo deverão ser do tamanho apropriado para os respectivos cabos, e deverão prender simultaneamente o isolamento e o fio condutor.
¡Atención!
Cuando se necesite hilo trenzado, utilizar terminales para cables homologados, tales como las de tipo "bucle cerrado" o "espada", con las
Copyright © 2017, Juniper Networks, Inc.
559
MX960 3D Universal Edge Router Hardware Guide lengüetas de conexión vueltas hacia arriba. Estos terminales deberán ser del tamaño apropiado para los cables que se utilicen, y tendrán que sujetar tanto el aislante como el conductor.
Varning!
När flertrådiga ledningar krävs måste godkända ledningskontakter användas, t.ex. kabelsko av sluten eller öppen typ med uppåtvänd tapp.
Storleken på dessa kontakter måste vara avpassad till ledningarna och måste kunna hålla både isoleringen och ledaren fastklämda.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
• DC Power Electrical Safety Guidelines for Switches
•
DC Power Disconnection Warning on page 554
•
DC Power Grounding Requirements and Warning on page 556
•
DC Power Wiring Sequence Warning on page 557
Midplane Energy Hazard Warning
WARNING: High levels of electrical energy are distributed across the midplane.
Be careful not to contact the midplane connectors, or any component connected to the midplane, with any metallic object while servicing components.
Multiple Power Supplies Disconnection Warning
WARNING: For a device that has more than one power supply connection, you must ensure that all power connections are fully disconnected so that power to the device is completely removed.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
•
AC Power Electrical Safety Guidelines on page 552
• DC Power Electrical Safety Guidelines for Switches
560 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
Action to Take After an Electrical Accident
If an electrical accident results in an injury, take the following actions in this order:
1.
Use caution. Be aware of potentially hazardous conditions that could cause further injury.
2.
Disconnect power from the device.
3.
If possible, send another person to get medical aid. Otherwise, assess the condition of the victim, then call for help.
Related
Documentation
•
General Safety Guidelines and Warnings on page 529
•
General Electrical Safety Guidelines and Warnings on page 550
•
AC Power Electrical Safety Guidelines on page 552
• DC Power Electrical Safety Guidelines for Switches
Agency Approvals and Compliance Statements
•
Agency Approvals and Compliance Statements for the MX2010 Router on page 561
•
Compliance Statements for EMC Requirements for Juniper Networks Devices on page 564
•
Compliance Statements for Environmental Requirements for Juniper Networks
•
Compliance Statements for NEBS on page 565
Agency Approvals and Compliance Statements for the MX2010 Router
•
Agency Approvals for MX2010 Routers on page 561
•
Compliance Statements for NEBS for the MX2010 Router on page 562
•
Compliance Statements for EMC Requirements for the MX2010 Router on page 563
•
Compliance Statements for Environmental Requirements for Juniper Networks
Agency Approvals for MX2010 Routers
The routers comply with the following standards:
• Safety
• CAN/CSA-22.2 No. 60950-00/UL 1950 Third Edition, Safety of Information
Technology Equipment
• EN 60825-1 Safety of Laser Products - Part 1: Equipment Classification, Requirements and User's Guide
Copyright © 2017, Juniper Networks, Inc.
561
MX960 3D Universal Edge Router Hardware Guide
562
• EN 60950 Safety of Information Technology Equipment
• EMC
• AS/NZS CISPR22: (Australia/New Zealand)
• EN55022 Class A (Europe)
• FCC Part 15 Class A (USA)
• VCCI Class A (Japan)
• Immunity
• EN-61000-3-2 Power Line Harmonics
• EN-61000-3-3 Voltage Fluctuations and Flicker
• EN-61000-4-2 ESD
• EN-61000-4-3 Radiated Immunity
• EN-61000-4-4 EFT
• EN-61000-4-5 Surge
• EN-61000-4-6 Low Frequency Common Immunity
• EN-61000-4-11 Voltage Dips and Sags
• ETSI
• ETSI EN-300386-2 Telecommunication Network Equipment. Electromagnetic
Compatibility Requirements
The router is designed to comply with the following standards:
• NEBS
• GR-1089-Core: EMC and Electrical Safety for Network Telecommunications
Equipment
• SR-3580 NEBS Criteria Levels (Level 3 Compliance)
• GR-63-Core: NEBS, Physical Protection
NOTE: The Premium 2 Chassis is not NEBs compliant.
Compliance Statements for NEBS for the MX2010 Router
• The equipment is suitable for installation as part of the Common Bonding Network
(CBN).
• The equipment is suitable for installation in locations where the National Electrical
Code (NEC) applies.
• The battery return connection is to be treated as an isolated DC return (that is, DC-I), as defined in GR-1089-CORE.
Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
Compliance Statements for EMC Requirements for the MX2010 Router
•
•
European Community on page 563
•
•
•
Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
European Community
This is a Class A product. In a domestic environment this product might cause radio interference in which case the user might be required to take adequate measures.
Israel
Translation from Hebrew—Warning: This product is Class A. In residential environments, the product might cause radio interference, and in such a situation, the user might be required to take adequate measures.
Japan
Translation from Japanese—This is a Class A product. In a domestic environment this product might cause radio interference in which case the user might be required to take adequate measures. VCCI-A
United States
The router has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, might cause harmful interference to radio communications. Operation of this equipment in a residential
Copyright © 2017, Juniper Networks, Inc.
563
MX960 3D Universal Edge Router Hardware Guide area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Compliance Statements for Environmental Requirements for Juniper Networks
Devices
Batteries in this product are not based on mercury, lead, or cadmium substances. The batteries used in this product are in compliance with EU Directives 91/157/EEC, 93/86/EEC, and 98/101/EEC. The product documentation includes instructional information about the proper method of reclamation and recycling.
Related
Documentation
Compliance Statements for EMC Requirements for Juniper Networks Devices
•
•
European Community on page 564
•
•
•
Canada
CAN ICES-3 (A)/NMB-3(A)
European Community
This is a Class A product. In a domestic environment, this product might cause radio interference in which case the user might be required to take adequate measures.
Israel
Translation from Hebrew—Warning: This product is Class A. In residential environments, the product might cause radio interference, and in such a situation, the user might be required to take adequate measures.
Japan
564 Copyright © 2017, Juniper Networks, Inc.
Chapter 35: Safety and Compliance Information
The preceding translates as follows:
This is a Class A product based on the standard of the Voluntary Control Council for
Interference by Information Technology Equipment (VCCI). If this product is used near a radio or television receiver in a domestic environment, it might cause radio interference.
Install and use the equipment according to the instruction manual. VCCI-A.
United States
The hardware equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, might cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Compliance Statements for Environmental Requirements for Juniper Networks Devices
Batteries in this product are not based on mercury, lead, or cadmium substances. The batteries used in this product are in compliance with EU Directives 91/157/EEC, 93/86/EEC, and 98/101/EEC. The product documentation includes instructional information about the proper method of reclamation and recycling.
Compliance Statements for NEBS
• The equipment is suitable for installation as part of the Common Bonding Network
(CBN).
• The equipment is suitable for installation in locations where the National Electrical
Code (NEC) applies.
• The battery return connection is to be treated as an isolated DC return (i.e. DC-I), as defined in GR-1089-CORE.
• For Juniper Networks systems with AC power supplies, an external surge protective device (SPD) must be used at the AC power source.
Copyright © 2017, Juniper Networks, Inc.
565
MX960 3D Universal Edge Router Hardware Guide
566 Copyright © 2017, Juniper Networks, Inc.
Atsisiųsti