Haier Novel HSU12VHG-W, Novel HSU12VHGDB-W Installation Manual


Add to my manuals
4 Pages

advertisement

Haier Novel HSU12VHG-W, Novel HSU12VHGDB-W Installation Manual | Manualzz

Installation Manual of Novel Series

Preparation

Necessary Tools for Installation

Ⴠ Drill

Ⴠ Nipper

Ⴠ Saw

Ⴠ Hole 2 3/4

Ⴠ Vacuum pump

Ⴠ Gas leakage detector or soap-and-water solution

Ⴠ Torque wrench

(17mm,22mm,26mm)

Ⴠ Pipe cutter

Ⴠ Flaring tool

Ⴠ Knife

Ⴠ Measuring tape

Ⴠ Reamer

Procedure for Selecting the Location

Choose a place solid enough to bear the weight and vibration of the unit,where the operation noise will not be amplified.

Choose a location where the hot air discharged from the unit or the operation noise,will not cause a nuisance to the neighbors of the user.

Avoid places near a bedroom and the like,so that the operation noise will cause no trouble.

There must be sufficient space for carrying the unit into and out of the site.

There must be sufficient space for air passage and no obstructions aroud the air inlet and air outlet.

The site must be free from the possibility of flammable gas leakage in a nearby place.

Locate the unit so that the noise and discharged hot air will not annoy the neighbors.

Ⴠ Install units,power cords and inter-unit cables at least 10ft away from televison and radio sets,This is prevent interference to images and sounds.(Noise may be heard even if they are more than 10ft away depending on radio wave conditions.)

In coastal areas or other places with salty atmosphere of sulfate gas,corrosion may shorten the life of the air condition.

Since drain flows out of the outdoor unit,do not place under the unit anything which must be kept away from moisture.

Drawing for the installation of indoor and outdoor units

2

Accessory parts

Remote controller (1)

AAA dry battery (2)

Mounting plate (1)

Plastic cap (4)

Ø4X25 Screw (4)

Drain hose (1)

Cushion (4)

Drain-elbow (1)

Pipe supporting plate (1)

Selection of pipe

Model

HSU09VHG(DB)-W

HSU12VHG(DB)-W

HSU18VHG(DB)-W

HSU24VHG(DB)-W

Liquid pipe (Ø)

6.35mm (1/4 ")

6.35mm (1/4 ")

6.35mm (1/4 ")

9.52mm (3/8 ")

Gas pipe (Ø)

9.52mm (3/8 ")

9.52mm (3/8 ")

12.7mm (1/2 ")

15.88mm (5/8")

NOTE ˖ The thickness of the pipe must be 0.8mm(1/16”) at least.

Indoor unit

Fitting of the Mounting Plate and Positioning of the wall Hole

When the mounting plate is first fixed

1. Carry out, based on the wall studs or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one nail.

2. Ensure the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten the plate.

3. Find the wall hole location A using a measuring tape

09k

B = Ø 60mm

(2 3/8 inches)

A = 145mm

(5 11/16 inches)

12k

B = Ø 60mm

(2 3/8 inches)

A = 145mm

(5 11/16 inches )

18k

B= 70mm

(2 3/4 inches )

A=150mm

(5 7/8 inches )

24k

A=150mm

(5 7/8 inches ) mm

(2 3/4 inches )

Making a Hole on the Wall and Fitting the Piping Hole Cover

ƽ Make a hole of B mm / inches in diameter, slightly descending to outside the wall.

ƽ Install piping hole cover and seal it off with putty after installation

Wall hole Pitch downward for drainage

ØBmm

09k/12k : B= 60mm(2 3/8 inches)

18k/24k : B=70mm(2 3/4 inches)

Indoor side

(Section of wall hole)

Outdoor side

Thickness of wall

G Piping hole pipe

Installation of the Indoor Unit

Drawing of pipe

[ Rear piping ]

ƽ Draw pipes and the drain hose, then fasten them with the adhesive tape

[ Left

·

Left-rear piping ]

ƽ In case of left side piping, cut away, with a nipper, the lid for left piping.

ƽ In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on insulation materials.

1. Insert the drain hose into the carity of heat insulation materials of indoor unit.

2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them.

3. Coat the flaring seal face with refrigerant oil and connect pipes.

Cover the tubing connection with insulation materials closely, and with adhesive tape.

Indoor/outdoor electric cable

Lid for right piping

Lid for under piping pipe

Fix with adhesive tape

Lid for left piping

Insulation material

Drain hose

Piping

Pipe supporting plate ƽ Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping with adhesive.

[ Other direction piping ]

ƽ Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to theposition of wall hole. When bending, be careful not to crush pipes.

ƽ Make sure that the wires connecting the indoor and outdoor units are not covered by the refrigeration piping insulation and are long enough to connect to the terminal block on the indoor unit.

Fixing the indoor unit body

ƽ Hang the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing.

ƽ In order to fix the body onto the mounting plate,hold up the body from the underside and then put it down perpendicularly.

Unloading of indoor unit body

mounting plate ƽ When you unload the indoor unit,please use your hand to raise the body , then lift the bottom of the body outward slightly and lift the unit until it leaves the mounting plate. agraffe mounting plate

4

Connection

ƽ Loosen the screws on terminal block and insert the wires fully into terminal block, then tighten the screws.

ƽ If wiring is not correct, the unit will not operate properly and it could cause a defect in the unit.

ƽ

Fix the cable with a clamp.

Attaching Drain-Elbow ƽ If the drain-elbow is used, please attach as shown in figure.

(Note: Only for heat pump unit.)

Purging Method:To use vacuum pump

1.

Detach the service port’s cap of 3-way valve, and the valve cap for 2-way valve and 3-way valve. Connect the service port to the low side of the gauge manifold and connect the vacuum pump to the center port of the manifold.

2.

Open the handle on the low side of the gauge manifold and operate vacuum pump.

3.

Vacuum the tubing for at least 15 minutes. The vacuum level on the low side gauge should be 29.9 in of Hg, 76 cm of Hg, 0.1 MPa. when vacuuming is complete, close the valve on the manifold and turn off the vacuum pump. The vacuum level should hold for 1-2 minutes. If the vacuum level does not hold, check the flared connections and repeat this step.

4.

Open the 2-way valve 1/4 turn. After 5-6 seconds, close the valve and inspect for leaks with a leak detector or soap solution.

5.

No gas leakage? Go to step 6.

In case of a leak, try tightening the flare connections to fix the leak. If the leak stops, go to step 6. If the leak continues, check the flare connections and repair as needed, then go back to step 3. then proceed step 6. If leak continues, remove the refrigerant used for the leakage check and flare tubes again. Repeat vacuum and leak and if no leakage, proceed to step 6.

6.

Detach the charge hose valve completely.

from the service port, open 2-way valve and 3-way

7.

To prevent the gas leakage, replace the service port and valve caps.

8.

After attaching the caps, check for leakage around the caps.

Step 1.

2-way valve Liquid Side

3-way valve Gas Side

Step 2.

Open

Gaugemanifold(for R410A)

Gauge manifold

Step 3.

Close

Tube(for R410A)

Vacuum pump

Step 4.

Open 90

O

2-way valve

3-way valve

Step 6.

2-way valve

3-way valve

Step 7.

2-way valve

3-way valve

2-way valve 3-way valve

Valve cap

Valve cap

Service port cap

CAUTION

ƽ

If the refrigerant of the air conditioner leaks, it is necessary to discharge all the refrigerant. Repair the leak, vacuum the unit then charge the liquid refrigerant ƽ into air conditioner according to the amount marked on the name plate.

Please do not let other cooling medium, except specified one (R410A), or air enter into the cooling circulation system. This could cause high pressure and could cause a leak and lead to personal injuries.

Power Source Installation ƽ ƽ ƽ

The power source must be exclusively used for air conditioner.

In the case of installing an air conditioner in a moist place, please install an earth leakage breaker.(GFCI)

For installation in other places, use an HVACR circuit breaker of time delay fuse.

On Drainage ƽ Please install the drain hose and ensure downward flow.

ƽ Please don’t do the drainage as shown below.

Less than

5cm

It becomes high midway.

The end is immersed in water.

It waves.

The gap with the ground is too small.

There is the bad smell from a ditch ƽ Please pour water in the drain pan of the indoor unit, and is proper.

ƽ In case that the attached drain hose is in a room, please to the hose to prevent condensation.

confirm that drainage apply insulation to

Ƶ

Refrigerant charge label

Contains fluorinated greenhouse gases covered by the Kyoto Protocol

R410A

2

1

1=

2= kg kg

1+2= kg

A

B

C

D

F E

This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere.

Refrigerant type:R410A

GWP* value:1975

GWP=global warming potential

Please fill in with indelible ink,

• 1 the factory refrigerant charge of the product

• 2 the additional refrigerant amount charged in the field and

• 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product.

The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover).

A contains fluorinated greenhouse gases covered by the Kyoto

Protocol

B factory refrigerant charge of the product: see unit name plate

C additional refrigerant amount charged in the field

D total refrigerant charge

E outdoor unit

F refrigerant cylinder and manifold for charging

Ƶ

Check for Installation and Test Run

Ƶ

Please kindly explain to our customers how to operate through the instruction manual.

Check Items for Test Run Put check mark in boxes

Gas leak from interconnecting tubing?

Installation is on the interconnecting tubing?

Are the connecting wirings of indoor and outdoor firmly inserted to the terminal block?

Is the connecting wiring of indoor and outdoor firmly fixed?

Is drainage securely carried out?

Is the ground wire securely connected?

Is the indoor unit securely fixed?

Is power source voltage the local codes?

Is there any noise?

Are the lights near the unit working normally?

Are cooling and heating (when in heat pump) performing normally?

Is the operation of room temperature control normal?

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement