DTS 512 is a sliding gate motor designed for securing and automating the movement of gates. It features easy motor direction change, auto-close functionality (with infrared beams for safety), a condominium/free exit loop mode, P.I.R.A.C. (Passive Infra Red Access Control) mode, and slowdown (ramp down) capability. It operates on either low voltage (16V AC) or high voltage (220V AC) power supply and has a built-in receiver compatible with Sentry rolling code transmitters.
advertisement
DTS 412/512/624
SLIDING GATE MOTOR
INSTALLATION MANUAL
DTS SECURITY
P.O.BOX 3399
EDENVALE
1610
TELEPHONE 086 1000 387
Alberton 011 907 8846
Centurion 012 653 4434
Edenvale 011 524 0707
Pretoria 012 548 2336
West Rand 011 760 6564
E-EEEE
Base plate-mounting instructions
www.dtssecurity.co.za
1
BASE PLATE MOUNTING INSTRUCTIONS
1.
Assemble base plate by fastening M10x30 Hex set screws into base plate from under the base plate up and tightening into position.
2.
Mount base plate with bolts 160mm from the centre of the gate track and centre of base plate a minimum of 250mm away from the gate opening.
3.
Secure the base plate to the gate track by welding the base plate directly to the gate track. (Ensuring a distance of 160mm from centre of gate track to centre of fastening screws).
4.
Fit all required cabling through hole provided in base plate.
5.
Support the back of the base plate with 40x40x3 angle iron (not provided) or similar off cut steel knocked approximately 300 to 400mm into the ground.
6.
Fill area below and around the base plate with approximately 300x400x300 concrete to ensure that the motor will be secure.
7.
NOTE - The DTS 412/624 motor must be fitted with a set of IR beams.
2
Gearbox mounting instructions
1.
Fit gearbox over mounting bolts protruding from base plate.
2.
Slide gate fully open and closed, insuring pinion gear has approximately 5mm clearance to gate at all times.
3.
Fasten gearbox down firmly to base plate using M10 washers and nuts.
Rack mounting instructions
1.
Unlock and pull manual override lever fully out to disengage gearbox.
2.
Using a 2,5 to 3mm spacer between the pinion gear and the rack, mount the rack using Tek screws No12x20 (not provided) and screw the rack to the gate starting from the tail of the gate and ensuring that the rack is mounted level.
(A spacer can also be put between motor and base plate when fitting rack).
NB : Ensure that one of the screws attaching the nylon rack to the angle is in line with the limit switch spring when the gate is fully closed.
Limit switch actuator mounting instructions
1.
Remove screw attaching the nylon rack to angle that is closest to the position that
you wish the gate to stop.
2.
Fit limit switch actuator with screw provided, screwing into the nylon rack.
3.
Adjust limit switch actuator so that the gate stops approximately 10mm before the post.
Magnetic limit actuator Spring limit actuator
Important: A solid stop must be fitted at both ends of the gate to prevent the gate from moving past its
full open or close position.
3
POWER CONNECTIONS
Low voltage Plug in transformer .
Connect 16V AC connectors on plug in transformer to 16V AC connectors on controller card.
DO NOT CONNECT 220V DIRECTLY TO PCB
Low voltage on board transformer – 220V at gate.
Connect 220V AC to input side of 16V AC transformer (black & brown wires), connect output
wires (red) to16V AC connectors on controller card.
DO NOT CONNECT 220V DIRECTLY TO PCB
IF 220V IS USED AT GATE MOTOR, A SEPARATE DOUBLE POLE ISOLATOR MUST
BE FITTED WITHIN 1M FROM MOTOR.
4
High access power supply unit – 220V at gate.
Connect 220V AC to LEN (Live/Earth/Neutral) connecto r on side of power supply unit.
Black lead from power supply unit gets connected to – ( neg.) PSU connection on Pcb.
Red lead from power supply unit gets connected to + ( pos.) PSU connection on Pcb.
DO NOT CONNECT 220V DIRECTLY TO PCB
DO NOT USE POWER SUPPLY (PSU) UNIT AND LOW VOLTAGE TRANSFORMER (16V AC) TOGETHER.
IF 220V IS USED AT GATE MOTOR, A SEPARATE DOUBLE POLE ISOLATOR MUST
BE FITTED WITHIN 1M FROM MOTOR.
COUR TESY LIGHT OUTPUT (Will stay on for 3 minutes after a trigger is received)
DO NOT CONNECT 220V DIRECTLY TO PCB UNDER ANY CIRCUMSTANCES
.
5
DO ALL RUNTIME AND TRANSMITTER PROGRAMMING BEFORE CONNECTING ANY ADDITIONAL
INPUTS SUCH AS, –INTERCOM, BEAMS ETC.
NOTE - IR beams must be fitted if DTS 412/624 motor is installed.
DO NOT CONNECT 220V DIRECTLY TO PCB
Dipswitch selections to activate a function.
Dipswitch 1 - Programming.
2 - Motor direction. (This can only be changed before programm ing or if neither limit
switches are activated).
3 – Auto close.
4 – Condominium mode.
5 – P.I.R.A.C. mode
6 – Slow down distance ch ange
Dipswitch selection for programming.
(With dipswitch 1 ON)
Dipswitch 3 – Auto close. (Infra red beams must be fitted if auto close is activated).
Dipswitch 4 – Pedestrian (Distance and time).
6
PROGRAMING
1 – Run Time Setup (This will automatically happen when triggered after total power up or
by following the steps below).
•
Gate approximately 1metre open
•
W ith all dipswitches OFF (excluding dipswitch 2 pending motor direction), press & release
Bt/SET button.
•
Gate will close, open and close again and stop on close limit (Motor speed can be increased
during programming of open cycle by pushing and ho lding down the Bt/SET button). The
closing cycle of programming wil
• l automatically run at fast speed.
Control card will beep to confirm end of run time setup.
NOTE: If gate opens first, dipswitch number 2 is wrongly selected.
2 – Auto close (Default 15 seconds) (Infra red beams must be fitted if auto close is activated).
•
Switch Dipswitch 1 and 3 on.
•
Press & hold Bt/SET button
•
PCB will Beep (1 Beep = 1 Sec)
•
Release Bt/SET button at required auto close time.
•
Switch Dipswitch 1 and 3 off.
•
Switch Dipswitch 3 back on to activate the auto close.
3 – Pedestrian Opening (Default 1 meter / 4 seconds auto close)
•
Switch Dipswitch 1 and 4 on.
•
Gate should be in closed positio n.
•
Press & Release Bt/SET Button.
•
Gate will open.
•
Press & release Bt/SET button to stop gate at required pedestrian o pening distance.
•
Press & Hold Bt/SET button to program auto close time required.
•
Control card will Beep (1 Beep = 1 Sec)
•
Release Bt/SET button at requ ired pedestrian auto close time.
•
Gate will close again.
•
Switch Dipswitch 1 and 4 off.
To reset factory default push Bt Lrn or Pd Lr n, then press and hold Bt/SET for approxim ately 5 seconds, the PCB will give 2 short b eeps as acknowledgement.
7
Load setting
To adjust the load, turn the provided load pot very slowly to determine the load setting (Minimum- a nticlockwise & Maximum clockwise). The control card will beep as you turn the pot (1 - 5 beeps).
ON BOARD RECEIVER PROGRAMING
The onboard receiver is designed to work with Sentry rolling code transmitters.
PROGRAMMING A
TRANSMITTER FOR FULL
OPEN OPERATION –Bt Lrn
1.
Push the Bt Lrn button, the
RX led will go on.
2.
Push the require d button on the transmitter, the board will give 2 beeps.
3 .
Repeat Step 1 and 2 for additional transmitters. Up to
25 transmitters can be programmed for this operation.
PROGRAMMING A
TRANSMITTER FOR PEDESTRIAN
OPERATION-Pd Lrn
1.
Push the Pd Lrn button, the
RX led will go on.
2.
Push the require d button on
the transmitter, the board
will give 2 beeps .
3 .
Repeat Step 1 and 2 for additional transmitters. Up to
5 transmitters can b e
programmed for this
operation.
The button used r used for L
To erase a button from the receiver, in case of incorre ct pro gramming i.e. blue button should b e for Bt Lrn and not Pd Lrn.
Simply push and hold th e Bt Lrn or th e Pd Lrn for 5 seconds, the board will give 1 beep. Th en push the button you want to erase, the board will give 2 beeps as confirmation. That button is then erased and can be learned into the correct input.
To master e rase:
Push and hold the Bt Lrn or the Pd Lrn button, after 5 seconds the board with give 1 b eeps. Keep holding for another 5 seconds then the board will give 2 beeps. All transmitters will now be erased.
8
ELECTRONICS
FEATURES:
1.
Standard
2.
Easy motor direction chang e
3.
4.
5.
6.
Auto close facility (Infra re
Condominium / Free exit loop facility
P.I.R.A.C (Passive Infra Re
Slowdown d beams must be fitted if a d Access Control) facility
(Ramp down) facility
1.
Standard Mode (No function selected) uto close is activated).
When the gate is activated it will open and can be stopped in mid cycle by pressing the transmitter or manual push button. Pressing the transm itter or push button can reverse the gate. In standard mode the gate will rem ain on its open limit until it is triggered to close.
If main power fails, the motor will still operate until battery reaches 20 volt. Gate will then remain close. Change to manual by overridi ng the motor by the override lever. When the main power comes on again, lock in the override lever and the motor will function as normal.
2.
Easy motor direction change (Dipsw itch 2)
By selecting the dipswitch, the motor direction and the limit wires are changed
a utomatically . Dipswitch ON, gate closes to the right. Dipswitch OFF, gate closes to the left.
3. Auto close (Dipswitch 3 On) (Infra red beams must be fitted if auto close is activated).
When Auto close is activated and the Gate opens to the open limit, the gate will wait the pre-programmed time before automatically closing. If the gate is triggered while the gate is in its closing cycle it will stop and reopen.
To override the auto close wait till the gate reaches its open limit then press & hold the transmitter or manual push button for 5 sec. (The control card will give 1 long beep to confirm the override) To reactivate the auto close, press the transmitter or manual push button.
If the transmitter or manual push button is pressed while the gate is in its opening cycle, the gate will close after the preprogrammed auto close time (from any position, not only from the open limit)
9
4. Condominium/free exit loop (Dipswitch 4 On)
When condominium/free exit loop is activated on the unit, the unit will not respond to an y transmit ter or manual push button while in its opening cycle or open position. When the gate is on the open limit the unit will automatically wait the pre-programmed auto close time and then close (even if auto close function is not selected i.e. dipswitch 3 is off).When
the gate is in its closing cycle and the transmitter or manual push button is pressed the gate will stop and open. Auto close cannot be over ridden in condominium mode. If main power
5. fails, the motor will still operate until battery reaches 20 volt. Gate will th en remain open.
Change to manual by overriding the motor by the override lever. When the main power comes on again, lock in the override lever and the motor will function as normal.
P.I.R.A.C (Passive Infra Red Access Control) (Dipswitch 5 On)
With P.I.R.A.C mode activated, if the gate is in its opening cycle and the IR beam is activated and released the gate will stop and close immediately. When the gate is on the open limit the unit will not automatically close unless auto close has been selected.
6. Slowdown (Dipswitch 6)
With dipswitch selected ON, the gate will have a long close and open ramp down distance, and with the dipswitch OFF, a short ramp down distance.
NO TE - (For any gate exceeding 3 meters width, the long ramp down is recommen ded).
10
PCB Control card.
For PCB identification
2 x Voltage regulators = 24V motor.
1 x Voltage regulator = 12V motor.
NB – When connecting intercoms to the control card, please ensure that your intercom trigger output is potential free (ZERO voltage). If not, a gate relay module must be fitted.
11
TROUBLESHOOTING
SYMPTOMS
When pressing the remote transmitter the gate operator will not respond at all
Or
PCB responds but gate will not open
When pressing either the transmitter or the PCB button or the hardwire button on the wall, the gate opens +- half a metre and stops.
CAUSES
Transmitter battery flat.
Transmitter physically damaged.
Transmitter has not been programmed into the receiver memory.
Condominium /loop option is not activated and the battery has reached its low level
(10/20 Volt) Indicated by 3 beeps / 3 beeps.
The transmitter is being pressed and held.
The button input is being pressed and held.
The button is jamming in the
N/C position or has been wired normally closed.
The opposite limit switch is jamming N/C or has been wired up N/C.
ACTION
Replace transmitter battery.
Check with supplier.
Follow the receiver setup instructions.
Check the household main supply, the transformer or PSU and all related cabling.
Press and release the transmitter button to operate the gate.
Press and release the button to operate the gate.
Replace the button or rewire the equipment.
Replace the switch, rewire correctly or check limit spring assembly.
12
Before operating, the unit gives two long beeps
The gate opens but will not close
The gate when closing stops and reverses or when opening stops.
OR
Gate tries to run and the relays kick out.
The primary supply has Check the household main failed and the unit is running supply, the transformer or on battery reserve. PSU and all related cabling.
The primary supply has failed and the unit is running on battery reserve with the condominium/loop option selected and it has reached its low battery limit (10/20 Volt) indicated by 3 beeps / 3 beeps.
Safety infra-red beams are obstructed or the beams equipment/cabling are faulty.
Check the household main supply, the transformer or
PSU and all related cabling.
Clear obstruction or repair/replace safety infra-red beams equipment/cable.
The unit is sensing an obstruction
The infra-red beam has been triggered.
Another trigger has been received by the control card.
Encoder is faulty.
Gate does not remain open. Auto close has been selected.
Another user has triggered the
When the beams input is triggered, the gate stops and reverses during opening cycles. unit.
Condominium/loop has been selected.
P.I.R.A.C. mode has been selected.
Gate is closing in the wrong direction.
Clear obstruction or adjust load sensing.
Clear obstruction.
Check with other operators on the system.
Turn ring magnet on the motor by hand: if no activity on the encoder LED, contact supplier.
Deselect auto close or use auto close override.
Deselect condominium / loop mode.
Deselect P.I.R.A.C. mode
Dipswitch 2 is selected incorrectly.
13
The unit beeps 3 times and opens partially, beeps 3 times and the closes. This can sometimes continue indefinitely.
When gate reaches a limit actuator, the unit does not stop running.
Gate motor is jumping teeth on the rack.
Gate jams in the open or closed position and is not easy to manually release .
The pedestrian (Pd) mode is being triggered. This is constant if the sequence keeps repeating.
Check with the other operators and check switching equipment / cabling attached to the (Pd) input.
A transmitter code has been programmed into the pedestrian (Pd Lrn) function of the receiver.
Receiver is faulty and transmitting constantly
Re-code the receiver as per instructions
Check with supplier.
Limit inputs wired incorrectly
(out of sync’ with the motor direction.)
Limit switch is faulty.
Re-wire
Check with supplier.
Re-align.
Re-align and correct fastening.
Pinion to rack spacing is incorrect.
Rack is insufficiently fastened to gate leaf.
Gate is running too far.
Gate is running past its limit actuator.
Adjust the limit actuators so that the gate does not ram into the end stops.
Replace the switch, rewire correctly or check limit spring assembly.
14
Manufacturers warranty
.
•
A ll goods manufacture d b y DTS Security carr y a 1 2 month factory wa rranty fr om date of invoice.
•
All goods are warranted to be free from faulty components and manufacture.
•
Faulty goods will be repair ed or replaced at the so l e discretion of DTS Sec urity
Products, free of charge.
•
This warranty is subject to the goods being return
Security Products.
•
This warranty excludes lig htening damage, in sect d amage and dama ge caused by faulty installation.
•
In the event of the goods being supplie d by dealer, merchant, agent or duly appointed installer of DTS Security Products, the claim must be directed to that supplier.
•
The carriage of goods is fo r the customer’s a ccount .
•
This w arranty is only valid if the correct instal lation and application of goods, as laid out in the applicable documentation accompanying said goods, is adhered to.
•
All warranty claims must be acco mpanied by the original i nvoice.
•
T he liability of DTS Se cur ity Products and / or thei r distributors is limite d as h erein set out DTS Sec y distributors will not be liable for consequential or incident damages howsoever arising.
15
advertisement
Related manuals
advertisement