Cabletron Systems MicroMMAC-34E Installation Manual
Pubblicità
Pubblicità
MicroMMAC
10BASE-T INTELLIGENT STACKABLE HUB
INSTALLATION GUIDE
MicroMMAC-24E 10BASE-T HUB
WITH
LANVIEW
R
CABLETRON
MicroMMAC-24
RCV
LNK
24 23 22 21 20 19 18 17 16 15 14 13
DISPLAY RESET
COM 2 COM 1
PWR
CPU
CLN
RCV
LNK
12 11 10 9 8 7 6 5 4 3 2 1
E
1
E
2
2 4 X 2 3X 2 2 X 2 1 X 2 0 X 19X 18X 17X 16 X 15 X 14 X 13 X
12X 11X 10X 9X 8X 7X 6X 5X 4X 3X 2X 1X
MicroMMAC-34E 10BASE-T HUB
WITH
LANVIEW
R
CABLETRON
MicroMMAC-34 RCV
LNK
24 23 22 21 20 19 18 17 16 15 14 13
DISPLAY RESET
COM 2 COM 1
PWR
CPU
CLN
RCV
LNK
12 11 10 9 8 7 6 5 4 3 2 1
E
1
E
2 24X
12X
13X
1X
EPIM 2
EPIM 1
EPIM 2
EPIM 1
NOTICE
Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron
Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL,
INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT
NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS MANUAL OR
THE INFORMATION CONTAINED IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN
ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH
DAMAGES.
Copyright 1996 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005
All Rights Reserved
Printed in the United States of America
Order Number: 9030908-02 April 1996
SPECTRUM , LANVIEW , MicroMMAC , and BRIM are registered trademarks and Element
Manager , EPIM , EPIM-A , EPIM-F1 , EPIM-F2 , EPIM-F3 , EPIM-T , EPIM-X , FOT-F , FOT-F3 ,
HubSTACK , SEH , SEHI , and TMS-3 are trademarks of Cabletron Systems, Inc.
All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.
Printed on
MicroMMAC Installation Guide
Recycled Paper i
Notice
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
DOC NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.
VCCI NOTICE
This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment (VCCI) aimed at preventing radio interference in commercial and/or industrial areas.
Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers, etc.
Read the instructions for correct handling.
ii MicroMMAC Installation Guide
Notice
CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT
IMPORTANT: Before utilizing this product, carefully read this License Agreement.
This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the
“Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING TO BECOME
BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES THE LICENSE AND
THE LIMITATION OF WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT
AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED
PRODUCT TO THE PLACE OF PURCHASE FOR A FULL REFUND.
CABLETRON SOFTWARE PROGRAM LICENSE
1.
LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement.
You may not copy, reproduce or transmit any part of the Program except as permitted by the
Copyright Act of the United States or as authorized in writing by Cabletron.
2.
OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the
Program.
3.
APPLICABLE LAW. This License Agreement shall be interpreted and governed under the laws and in the state and federal courts of New Hampshire. You accept the personal jurisdiction and venue of the New Hampshire courts.
EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY
1.
EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO
YOU BY CABLETRON IN WRITING, EITHER EXPRESSED OR IMPLIED, INCLUDING
BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE PROGRAM, THE
ACCOMPANYING WRITTEN MATERIALS, AND ANY ACCOMPANYING HARDWARE.
2.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL
CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER
(INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS,
PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL,
INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS)
ARISING OUT OF THE USE OR INABILITY TO USE THIS CABLETRON PRODUCT,
EVEN IF CABLETRON HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR
ON THE DURATION OR LIMITATION OF IMPLIED WARRANTIES, IN SOME
INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO
YOU.
MicroMMAC Installation Guide iii
Notice
UNITED STATES GOVERNMENT RESTRICTED RIGHTS
The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the
Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects is proprietary data belonging to Cabletron and/or its suppliers.
For Department of Defense units, the product is licensed with “Restricted Rights” as defined in the
DoD Supplement to the Federal Acquisition Regulations, Section 52.227-7013 (c) (1) (ii) and its successors, and use, duplication, disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at
252.227-7013. Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03867-0505.
iv MicroMMAC Installation Guide
Notice
DECLARATION OF CONFORMITY
Application of Council Directive(s): 89/336/EEC
73/23/EEC
Manufacturer’s Name: Cabletron Systems, Inc.
Manufacturer’s Address: 35 Industrial Way
PO Box 5005
Rochester, NH 03867
European Representative Name: Mr. J. Solari
European Representative Address: Cabletron Systems Limited
Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG13 2PZ, England
Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC
EC Directive 73/23/EEC
EN 55022
EN 50082-1
EN 60950
Equipment Type/Environment: Networking Equipment, for use in a
Commercial or Light Industrial
Environment.
We the undersigned, hereby declare that the equipment packaged with this notice conforms to the above directives.
Manufacturer Legal Representative in Europe
Full Name
Title
Location
Full Name
Title
Location
MicroMMAC Installation Guide v
Contents
CHAPTER 1 INTRODUCTION
1.1
How to Use This Manual ............................................................. 1-1
1.2
Manual Organization ................................................................... 1-1
1.3
Document Conventions ............................................................... 1-2
1.4
MicroMMAC Overview................................................................. 1-3
1.5
MicroMMAC Features.................................................................. 1-4
1.6
Stackable Capabilities ................................................................. 1-6
1.7
Remote Network Management Capabilities ................................ 1-7
1.8
Optional Features ........................................................................ 1-8
1.9
Related Manuals.......................................................................... 1-9
1.10 Getting Help............................................................................... 1-10
CHAPTER 2 CONTROLS AND INDICATORS
2.1
Identifying MicroMMAC Components .......................................... 2-1
2.2
Turning the MicroMMAC ON and OFF ........................................ 2-2
2.3
Using the LCD and LCD DISPLAY Button .................................. 2-2
2.3.1
Static System Messages ................................................ 2-3
2.3.2
Saved Alarm Messages .................................................. 2-4
2.3.3
Unsaved Initialization Messages .................................... 2-5
2.3.4
Saved System Messages ............................................... 2-6
2.4
Using the Reset Button................................................................ 2-7
2.5
Using the NVRAM Switch............................................................ 2-8
CHAPTER 3 INSTALLATION
3.1
Unpacking the MicroMMAC......................................................... 3-1
3.2
Removing the Chassis Cover ...................................................... 3-2
3.3
Setting the Mode Switches .......................................................... 3-4
3.4
Upgrading the FLASH SIMM ....................................................... 3-6
3.5
Adding/Replacing EPIMs............................................................. 3-8
3.6
Adding/Replacing BRIMs............................................................. 3-9
3.7
Testing the MicroMMAC .............................................................. 3-9
3.8
Installing the MicroMMAC.......................................................... 3-10
3.8.1
Shelf or Tabletop Installation ........................................ 3-11
3.8.2
Attaching the Strain-Relief Bracket ............................... 3-12
3.8.3
Rack Mounting the MicroMMAC ................................... 3-13
3.8.4
Stacking the MicroMMAC ............................................. 3-14
MicroMMAC Installation Guide vii
Contents
CHAPTER 4 CONNECTING TO THE NETWORK
4.1
Connecting the MicroMMAC to the Network ................................4-1
4.1.1
Connecting a 10BASE-T Segment to the MicroMMAC-22E and MicroMMAC-24E4-2
4.1.2
Connecting a 10BASE-T Segment to the MicroMMAC-32E and MicroMMAC-34E4-3
4.1.3
Connecting a 10BASE-T Segment to an EPIM-T............4-5
4.1.4
Connecting a 10BASE-F Segment to an EPIM-F1..........4-6
4.1.5
Connecting a 10BASE-F Segment to an EPIM-F2 or
EPIM-F34-8
4.1.6
Connecting a 10BASE2 Segment to an EPIM-C...........4-10
4.1.7
Connecting an AUI Segment to an EPIM-A ..................4-11
4.1.8
Connecting an AUI Segment to an EPIM-X ..................4-13
CHAPTER 5 TROUBLESHOOTING
5.1
Using LANVIEW...........................................................................5-1
5.2
Troubleshooting Checklist............................................................5-3
APPENDIX A MicroMMAC SPECIFICATIONS
A.1
Operating Specifications ............................................................. A-1
A.2
Power Supply Requirements ...................................................... A-1
A.3
Environmental Requirements...................................................... A-2
A.4
Agency Approvals ....................................................................... A-2
A.5
EMI Requirements ...................................................................... A-2
A.6
EMC Requirements..................................................................... A-2
A.7
Physical Specifications ............................................................... A-2
APPENDIX B EPIM SPECIFICATIONS
B.1
EPIM-T ........................................................................................ B-1
B.2
EPIM-F1 and EPIM-F2................................................................ B-2
B.3
EPIM-F3 ...................................................................................... B-3
B.4
EPIM-C ....................................................................................... B-5
B.5
EPIM-A and EPIM-X ................................................................... B-6 viii MicroMMAC Installation Guide
Contents
APPENDIX C NETWORK PLANNING AND CONFIGURATION
C.1
Network Cable Requirements......................................................C-1
C.1.1
HubSTACK Interconnect Cable ......................................C-1
C.1.2
10BASE-T UTP and STP Cable......................................C-2
C.1.3
Multimode Fiber Optic Cable...........................................C-4
C.1.4
Single Mode Fiber Optic Cable .......................................C-5
C.1.5
10BASE2 Thin Coaxial Cable .........................................C-6
C.1.6
AUI Cable ........................................................................C-7
C.2
Network Port Specifications.........................................................C-7
C.2.1
MicroMMAC-22E and MicroMMAC-24E
Network PortsC-8
C.2.2
MicroMMAC-32E and MicroMMAC-34E
Network PortsC-8
C.3
COM Port Specifications ...........................................................C-10
C.4
Transceiver Requirements ........................................................C-10
INDEX
MicroMMAC Installation Guide ix
CHAPTER 1
INTRODUCTION
Welcome to the Cabletron Systems MicroMMAC 10BASE-T
Intelligent Stackable Hub Installation Guide . This manual provides installation instructions and reference information for the
MicroMMAC-22E, MicroMMAC-24E, MicroMMAC-32E,
MicroMMAC-34E, MicroMMAC-22ES, MicroMMAC-24ES,
MicroMMAC-32ES, and MicroMMAC-34ES.
NOTE
Unless it is noted differently in this guide, the term MicroMMAC refers to the MicroMMAC-22E, MicroMMAC-24E,
MicroMMAC-32E, MicroMMAC-34E, MicroMMAC-22ES,
MicroMMAC-24ES, MicroMMAC-32ES, and
MicroMMAC-34ES.
1.1 HOW TO USE THIS MANUAL
Read through this manual to gain an understanding of the features and capabilities of the MicroMMAC. A general knowledge of Ethernet and
IEEE 802.3 type data communications networks and their physical layer components is helpful when installing the MicroMMAC.
1.2 MANUAL ORGANIZATION
This manual contains the following chapters and appendices:
Chapter 1, Introduction , outlines the contents of this manual, briefly describes MicroMMAC features, and concludes with a list of related manuals.
Chapter 2, Controls and Indicators , shows the controls and indicators of the MicroMMAC.
Chapter 3, Installation , describes how to install the MicroMMAC as a stackable or standalone device.
Chapter 4, Connecting to the Network , explains how to connect the
MicroMMAC to the network using the various media types.
MicroMMAC Installation Guide Page 1-1
Chapter 1: Introduction
Chapter 5, Troubleshooting , describes how to use the LANVIEW LEDs to troubleshoot network problems.
Appendix A, MicroMMAC Specifications , provides the physical properties, environmental operating requirements, agency approvals, and power requirements.
Appendix B, EPIM Specifications , lists specifications for each of the optional EPIMs available for the MicroMMAC.
Appendix C, Network Planning and Configuration , provides network cable requirements.
1.3 DOCUMENT CONVENTIONS
The following conventions are used throughout this document:
NOTE
Note symbol. Calls the reader’s attention to any item of information that may be of special importance.
TIP
Tip symbol. Conveys helpful hints concerning procedures or actions.
!
C AUT IO N
Caution symbol. Contains information essential to avoid damage to the equipment.
Warning symbol. Warns against an action that could result in equipment damage, personal injury or death.
Page 1-2 MicroMMAC Installation Guide
MicroMMAC Overview
1.4 MicroMMAC OVERVIEW
The MicroMMAC is an intelligent, repeating hub that provides complete
SNMP management to as many as four Stackable Ethernet Hub (SEH) series non-intelligent hubs. The MicroMMAC has front panel ports for network connections and a rear panel HubSTACK Interconnect Bus port for stackable connections. In addition, the MicroMMAC has a rear panel port that supports one Cabletron Systems Bridge Router Interface Module
(BRIM). BRIMs provide bridging/routing capability for Asynchronous
Transfer Mode (ATM), Ethernet, Fiber Distributed Data Interface (FDDI),
Token Ring, and Wide Area Network (WAN) connections.
•
•
•
•
•
The MicroMMAC provides front panel Ethernet connections using either
RJ45 connectors or RJ21 connectors. In addition, the MicroMMAC provides two ports for Ethernet Port Interface Modules (EPIMs). EPIMs provide connectivity for unshielded twisted pair, shielded twisted pair, multimode fiber optic, single mode fiber optic, or thin coaxial cable.
•
•
•
The following list describes each configuration of the MicroMMAC:
MicroMMAC-22E and one BRIM port.
provides 12 RJ45 network ports, one EPIM port,
MicroMMAC-24E provides 24 RJ45 network ports, two EPIM ports, and one BRIM port.
MicroMMAC-32E provides one RJ21 connector (providing 12 twisted pair segments), one EPIM port, and one BRIM port.
MicroMMAC-34E provides two RJ21 connectors (providing 24 twisted pair segments), two EPIM ports, and one BRIM port.
MicroMMAC-22ES provides 12 RJ45 network ports, one EPIM port, one BRIM port, and Cabletron Systems LANVIEW SECURE .
MicroMMAC-24ES provides 24 RJ45 network ports, two EPIM ports, one BRIM port, and Cabletron Systems LANVIEW SECURE .
MicroMMAC-32ES provides one RJ21 connector (providing 12 twisted pair segments), one EPIM port, one BRIM port, and Cabletron
Systems LANVIEW SECURE .
MicroMMAC-34ES provides two RJ21 connectors (providing 24 twisted pair segments), two EPIM ports, one BRIM port, and
Cabletron Systems LANVIEW SECURE .
MicroMMAC Installation Guide Page 1-3
Chapter 1: Introduction
1.5 MicroMMAC FEATURES
Repeater Functionality
The MicroMMAC fully conforms to the IEEE 802.3 Repeater, AUI, and
10BASE-T specifications, and provides the flexibility to connect networks using IEEE 802.3, Ethernet Version 1 or Version 2 equipment.
The MicroMMAC transmits retimed data packets, regenerates the preamble, extends fragments, and arbitrates collisions.
The MicroMMAC automatically partitions problem segments, and reconnects repaired segments to the network. This feature minimizes the impact on network operation resulting from a problem on one segment by isolating the problem segment. Only devices on the problem segment are affected. When the problem is solved, the MicroMMAC automatically reconnects the isolated segment to the network.
Polarity Detection and Correction
Each twisted pair port on the MicroMMAC incorporates a Polarity
Detection and Correction feature. This feature allows the MicroMMAC to pass data regardless of the polarity of the twisted pair segment’s receive link. Cabletron Systems does not recommend operating in this condition.
If you discover this condition, remove the segment from the network and wire it correctly. This reduces the potential for problems in the future if equipment changes are made.
Local Management
Local Management allows you to manage the MicroMMAC and all its attached segments. It also provides full packet and error statistics for the entire stack, individual device, or individual port. You access Local
Management by attaching a DEC VT320 terminal or a PC using VT320 emulation software to the MicroMMAC’s RJ45 COM 2 port. Refer to the
MicroMMAC Local Management User’s Guide for instructions on how to use Local Management.
LANVIEW LED
Cabletron Systems LANVIEW status monitoring and diagnostics system is a troubleshooting tool that helps diagnose power failures, collisions, cable faults, and link problems. LANVIEW LEDs are conveniently located on the MicroMMAC front panel.
Page 1-4 MicroMMAC Installation Guide
MicroMMAC Features
LCD
The MicroMMAC is equipped with an LCD that provides information about the MicroMMAC such as power up diagnostics, firmware revisions,
MAC and IP addresses, and error alerts.
Reset Button
The Reset button lets you re-boot and initialize the processor.
Intelligence
The MicroMMAC is equipped with an advanced Intel i960 microprocessor to provide a scalable RISC-based architecture.
Management Information Base (MIB) Support
The MicroMMAC provides IETF MIB support which includes the following:
• Remote Monitoring MIB (RMON)
• Bridge MIB
• MIBII
Serial Connections
The MicroMMAC provides two RJ45 ports (COM 1 and COM 2) for serial connections. The COM ports allow access to Local Management by locally connecting a DEC VT220 or VT320 terminal, or a PC using VT emulation software. The COM ports also provide a connection for an
Uninterruptible Power Supply (UPS).
DLM
Cabletron Systems Distributed LAN Monitor (DLM) is a software option for the MicroMMAC. DLM provides a method to locally poll and monitor any Simple Network Management Protocol (SNMP) or Internet Protocol
(IP) device using a remote management application.
MicroMMAC Installation Guide Page 1-5
Chapter 1: Introduction
•
•
FLASH EEPROMs
The MicroMMAC uses FLASH Electrically Erasable Programmable
Read Only Memory (EEPROM) which allows you to download new and updated firmware using SPECTRUM Element Manager for Windows or any device using BOOTP or tftp protocols.
The MicroMMAC supports the following download applications:
Standard Download - the MicroMMAC automatically becomes disabled while the new firmware image loads directly into Local
Dynamic Random Access Memory (LDRAM). You can not perform a
Standard Download through a BRIM interface.
Runtime Download - the MicroMMAC continues to operate without interruption while you download the new firmware image directly into
FLASH memory. The original firmware image in LDRAM continues to run until the MicroMMAC is reset. You can perform a Runtime
Download through any network port, including the BRIM.
1.6 STACKABLE CAPABILITIES
The MicroMMAC can be stacked together with Cabletron Systems SEH series of non-intelligent hubs. You can stack as many as four non-intelligent hubs with one MicroMMAC. The MicroMMAC provides complete management for the stack, including full packet and error statistics for the entire stack, individual device, or individual port. You can also add or remove hubs from the stack without having to power down.
Stackable configurations let you maintain only one IEEE repeater hop while providing up to 130 Ethernet ports. The rear panel HubSTACK
Interconnect Bus Out port of the MicroMMAC lets you daisy chain hubs together using the HubSTACK Interconnect cable. Figure 1-1 shows a typical stackable configuration.
Page 1-6 MicroMMAC Installation Guide
Remote Network Management Capabilities
REAR VIEW
MicroMMAC MANAGING 4 SEH NON-INTELLIGENT HUBS
HubSTACK 10BASE-T HUB
WITH
LANVIEW®
SEH-24
OUT SEH INTERCONNECT IN
HubSTACK 10BASE-T HUB
WITH
SEH-24
LANVIEW®
OUT SEH INTERCONNECT
HubSTACK
10BASE-T HUB
WITH
SEH-24
LANVIEW®
IN
OUT SEH INTERCONNECT IN
HubSTACK 10BASE-T HUB
WITH
SEH-24
LANVIEW®
OUT SEH INTERCONNECT IN
MicroMMAC-34E 10BASE-T HUB
WITH
LANVIEW®
LINE:
100-125V - 4.0A
200-250V - 2.0A
50/60Hz
SN
SEH INTERCONNECT
OUT
090802
Figure 1-1 Typical Stackable Configuration
1.7 REMOTE NETWORK MANAGEMENT CAPABILITIES
You can manage the MicroMMAC remotely by any SNMP network management system. Cabletron Systems offers the following remote management packages:
• Cabletron Systems SPECTRUM
• Cabletron Systems SPECTRUM Element Manager for Windows
• Cabletron Systems Remote SPECTRUM Portable Management
Applications
MicroMMAC Installation Guide Page 1-7
Chapter 1: Introduction
1.8 OPTIONAL FEATURES
The following features are not included with the MicroMMAC, but can be purchased separately from Cabletron Systems.
Bridging/Routing Capabilities
Bridge Router Interface Modules (BRIMs) provide the MicroMMAC with bridging/routing capability. Cabletron Systems offers BRIMs that support the following technologies:
• Asynchronous Transfer Mode (ATM)
• Ethernet
• Fast Ethernet
• Fiber Distributed Data Interface (FDDI)
• Token Ring
• Wide Area Network (WAN)
NOTE
Refer to the release notes included with the MicroMMAC for a list of available BRIMs.
Ethernet Port Interface Modules (EPIMs)
EPIMs provide the MicroMMAC with Ethernet connectivity to a variety of media. Cabletron Systems offers the EPIMs shown in Table 1-1.
Page 1-8 MicroMMAC Installation Guide
EPIM
EPIM-A
EPIM-C
EPIM-F1
EPIM-F2
EPIM-F3
EPIM-T
EPIM-X
Related Manuals
Table 1-1 EPIMs
Media Type
AUI
10BASE2 Thin Coaxial
Multimode Fiber
Multimode Fiber
Single Mode Fiber
10BASE-T Unshielded Twisted Pair
Standard Transceiver
Connectors
DB15 (Female)
BNC
SMA
ST
ST
RJ45
DB15 (Male)
HubSTACK Interconnect Cables
HubSTACK Interconnect cables link the MicroMMAC to SEH hubs in the stack. Table 1-2 lists the part number and application for each cable.
Part Number
9380110
9380111
Table 1-2 HubSTACK Interconnect Cables
Description
12” HubSTACK Interconnect
Cable
18” HubSTACK Interconnect
Cable
Application
SEH to SEH connections
MicroMMAC to SEH connections
1.9 RELATED MANUALS
Use the following manuals to supplement the procedures and other technical data provided in this manual. The procedures contained in the following manuals are referenced where appropriate, but not repeated in this manual.
• Cabletron Systems SEH Series User’s Guides
• Cabletron Systems BRIM User's Guides
MicroMMAC Installation Guide Page 1-9
Chapter 1: Introduction
1.10 GETTING HELP
If you need additional support related to the MicroMMAC, or if you have any questions, comments, or suggestions concerning this manual, contact
Cabletron Systems Technical Support:
By phone
By CompuServe
By Internet mail
By FTP
Login
Password
(603) 332-9400
Monday – Friday; 8 A .
M . – 8 P .
M . Eastern Time
GO CTRON from any ! prompt [email protected]
ctron.com (134.141.197.25) anonymous your email address
Before calling Cabletron Systems Technical Support, have the following information ready:
• A description of the failure
• A description of any action(s) already taken to resolve the problem
(e.g., changing mode switches, rebooting the unit, etc.)
• A description of your network environment (layout, cable type, etc.)
• Network load and frame size at the time of trouble (if known)
• The serial and revision numbers of all Cabletron Systems products in the network
• The device history (i.e., have you returned the device before, is this a recurring problem, etc.)
• Any previous Return Material Authorization (RMA) numbers
Page 1-10 MicroMMAC Installation Guide
CHAPTER 2
CONTROLS AND INDICATORS
This chapter describes how to identify and use the controls and indicators of the MicroMMAC.
2.1 IDENTIFYING MicroMMAC COMPONENTS
Figure 2-1 shows each of the MicroMMAC’s operational components.
FRONT VIEW
MicroMMAC-24E 10BASE-T HUB
WITH
LANVIEW
R
CABLETRON
MicroMMAC-24 RCV
LNK
24 23 22 21 20 19 18 17 16 15 14 13
E
2
DISPLAY RESET
COM 2 COM 1
PWR
CPU
CLN
RCV
LNK
12 11 10
9 8 7 6 5 4
3 2 1
E
1
2 4 X 2 3X 2 2 X 2 1 X 2 0 X 19X
12X 11X 10X 9X 8X 7X
PORT STATUS LEDS
SYSTEM LEDS
LCD
COM PORTS
RESET BUTTON
LCD DISPLAY BUTTON
18X 17X 16 X 15 X 14 X 13 X
6X 5X 4X 3X 2X 1X
NETWORK PORTS
EPIM 2
EPIM 1
EPIM PORTS
REAR VIEW
MicroMMAC-24E 10BASE-T HUB
WITH
LANVIEW®
LINE:
100-125V - 4.0A
200-250V - 2.0A
50/60Hz
SN
SEH INTERCONNECT
OUT
BRIM PORT
POWER CORD CONNECTOR
HubSTACK INTERCONNECT PORT
SIDE VIEW
NVRAM SWITCH ACCESS
Figure 2-1 MicroMMAC Components
090829
MicroMMAC Installation Guide Page 2-1
Chapter 2: Controls and Indicators
2.2 TURNING THE MicroMMAC ON AND OFF
NOTE
The MicroMMAC is NOT equipped with a Power ON/OFF switch.
To power-on the MicroMMAC, perform the following steps:
1. Plug the power cord into the power cord connector on the back panel of the MicroMMAC.
2. Plug the other end of the power cord into a grounded wall outlet.
3. Verify that the PWR LED is on, indicating that the MicroMMAC is receiving power. After the MicroMMAC runs a self test, the CPU
LED blinks green indicating normal operation. If the LED remains red, the processor is faulty; contact Cabletron Systems Technical
Support.
To power-off the MicroMMAC, disconnect the power cord from the power outlet.
2.3 USING THE LCD AND LCD DISPLAY BUTTON
The LCD provides information about the operation of the MicroMMAC and network activity. Four types of messages appear on the LCD:
• Static System Messages
• Saved Alarm Messages
• Unsaved Initialization Messages
• Saved System Messages
The following sections describe each type of LCD message and provide instructions for displaying them.
Page 2-2 MicroMMAC Installation Guide
Using the LCD and LCD DISPLAY Button
2.3.1 Static System Messages
Static System messages provide MicroMMAC configuration information.
Table 2-1 lists each message. To view Static System messages, perform the following steps:
1. Press and immediately release the Display button to view the first
Static System Message in the queue.
2. Press and release the Display button to display each subsequent message.
If the Display button is not pressed again for ten seconds, the LCD defaults to the product name.
MAC Address
00001dxxxxxx
RAM Image
Rev. xx.xx.xx
Boot PROM
Rev. xx.xx.xx
Flash Programmed xx Times
COM 1 Port
Baud Rate xxxxx
COM 1 Port
Function xxxxx
COM 2 Port Baud Rate xxxxx
COM 2 Port
Function xxxxxx
Table 2-1 Static System Messages
Displayed Messages
IP Address xxx.xxx.xxx.xxx
Comments
Displays the MicroMMAC’s IP address. The IP address can be changed through Local
Management.
Displays the MicroMMAC’s MAC address (this address is also called the physical address).
Displays the revision number of the image currently executing in FLASH.
Displays the revision number of the internal
Boot PROM.
Displays the number of times FLASH has been programmed.
Displays the Baud Rate for the COM 1 port. The default setting is AUTO because the
MicroMMAC uses Auto-Baud detection.
Displays the current function of the COM 1 Port
(N/A, UPS, LM).
Displays the baud rate for the COM 2 port. The default setting is AUTO because the
MicroMMAC uses Auto-Baud detection.
Displays the current function of the COM 2 Port
(N/A, UPS, LM).
MicroMMAC Installation Guide Page 2-3
Chapter 2: Controls and Indicators
2.3.2 Saved Alarm Messages
Saved Alarm messages describe events that occur within the
MicroMMAC or on the network. Table 2-2 shows each Saved Alarm message. To view Saved Alarm messages, perform the following steps:
1. Press the Display button for five seconds and then release to view the first Saved Alarm message in the message queue.
2. Press and immediately release the Display button to scroll through each subsequent message.
If the Display button is not pressed again for 10 seconds, the LCD defaults to the product name.
Port xxxxxx
Segmented
Port xxxxxx
UnSegmented
Port xxxxxx
Link Established
Port xxxxxx
Not Linked
EPIM-x
Inserted
EPIM-x
Removed
EPIM-x
Security Violation
CableRedun Fail
Port EPIM-x
CableRedun Enable
Port EPIM-x
Port xxxxxx
Disabled
Table 2-2 Saved Alarm Messages
Displayed Messages
No Messages in Queue
Comments
No Alarm messages in queue. This is the default setting.
Displays segmentation status of network ports
1–24, EPIM-1 or EPIM-2.
Displays segmentation status of network ports
1–24, EPIM-1, or EPIM-2.
Displays link status of network ports 1–24,
EPIM-1, EPIM-2, or BRIM-1.
Displays link status of network ports 1–24,
EPIM-1, EPIM-2, or BRIM-1.
Displays installation status of EPIM-1 or
EPIM-2.
Displays installation status of EPIM-1 or
EPIM-2.
Indicates unauthorized access attempt at
EPIM-1 or EPIM-2.
Indicates failure of redundant link at EPIM-1 or
EPIM-2.
Indicates redundant link enabled.
EPIM-1 or EPIM-2.
Indicates network ports 1–24, EPIM-1, or
EPIM-2 disabled.
Page 2-4 MicroMMAC Installation Guide
Using the LCD and LCD DISPLAY Button
Table 2-2 Saved Alarm Messages (Continued)
Displayed Messages
Port xxxxxx
Enabled
Port xx Security
Violation
Cable Redundancy
Port xxxxxx Failure
Cable Redundancy
Enable Port xxxxxx
Comments
Indicates network ports 1–24, EPIM-1, or
EPIM-2 enabled.
Indicates unauthorized access attempt at ports
1–24.
Indicates failure of redundant link at ports 1–24,
EPIM-1, or EPIM-2.
Indicates redundant link enabled at ports 1–24,
EPIM-1, or EPIM-2.
2.3.3 Unsaved Initialization Messages
Unsaved Initialization messages are power-up messages that appear as the event occurs, but are not saved in a buffer for future recall. Table 2-3 lists
Unsaved Failure or Error messages and Table 2-4 lists normal Unsaved
Initialization messages.
!
CAUTION
If Failure or Error Messages appear, call Cabletron Systems
Technical Support.
Table 2-3 Unsaved Failure or Error Messages
Cabletron
Ctrl. Reg. Err.
Cabletron
SDRAM Failure
Cabletron
SONIC Failure
Cabletron
Console SCC Error
Cabletron
82C54 Failure
Cabletron
BBRAM Failure
Cabletron
Modem SCC Error
Cabletron
Bit Swap Failure
Cabletron
LDRAM Failure
MicroMMAC Installation Guide Page 2-5
Chapter 2: Controls and Indicators
Table 2-4 Normal Unsaved Initialization Messages
Cabletron
Hardware Init
Cabletron
BOOTP Discovery
Cabletron
TFTP Req. State
Cabletron
TFTP Complete
Cabletron
Programming Flash
Cabletron
Boot Complete
Cabletron
Boot From Flash
Cabletron
RARP Req. State
Cabletron
TFTP in Progress
Cabletron
Erasing Flash
Cabletron
Flash Programmed
Cabletron
Test in Progress
2.3.4 Saved System Messages
Saved System messages are device related startup or boot strap messages,
BOOTP/tftp host, or startup error messages. To access the Saved System messages queue, perform the following steps:
1. Enter the Saved Alarm messages queue as described in Section 2.3.2.
2. Press the Display button for two seconds and then release to display the first Saved System message.
3. Press and immediately release the Display button to display each subsequent message.
If the Display button is not pressed again for ten seconds, the LCD defaults to the product name.
Page 2-6 MicroMMAC Installation Guide
Using the Reset Button
Table 2-5 Saved System Messages
Displayed Messages
BootP Host xxx.xxx.xxx.xxx
TFTP Host xxx.xxx.xxx.xxx
Last TFTP Host xxx.xxx.xxx.xxx
TFTP File xxxxxxxxxxxxxxxx
Last TFTP File xxx.xxx.xxx.xxx
Comments
The IP address of the server from which a
BootP image was downloaded to the
MicroMMAC.
The IP address of the server from which a
BootP image was downloaded to the
MicroMMAC.
The IP address of the server from which the most recent BootP image was downloaded to the MicroMMAC.
The filename of an image downloaded to the
MicroMMAC.
The filename of the most recently downloaded image to the MicroMMAC.
2.4 USING THE RESET BUTTON
Use the Reset button to initialize (reboot) the MicroMMAC processor.
Pressing the Reset button causes the hub to clear all counters, run self-test diagnostics, and reload the firmware image into Local Dynamic Random
Access Memory (LDRAM).
NOTE
The Reset button does not clear Non-Volatile Random Access
Memory (NVRAM).
Use a pen or pencil to press the Reset button. The MicroMMAC re-boots and initializes the processor.
MicroMMAC Installation Guide Page 2-7
Chapter 2: Controls and Indicators
2.5 USING THE NVRAM SWITCH
NOTE
It is not necessary to remove the chassis cover from the
MicroMMAC to gain access to the NVRAM switch.
To prevent the possibility of electrical shock, use only a non-metallic tool when operating the NVRAM switch.
NVRAM (Non-Volatile Random Access Memory) stores user-entered parameters such as community names, port configuration settings, and the
IP address. The NVRAM switch is accessible through the last lower circulation vent on the right side panel (see Figure 2-2). To clear
NVRAM, perform the following steps:
!
CAUTION
Do not clear NVRAM unless you intend to reset the
MicroMMAC user parameters to the factory default settings.
1. Ensure that the MicroMMAC is powered-on.
2. Use a non-metallic tool to change the state of the NVRAM switch.
For example: Move the switch from one position to another.
3. Press the Reset button. The MicroMMAC reboots and returns all user-entered parameters to the factory default settings.
Page 2-8 MicroMMAC Installation Guide
Using the NVRAM Switch
REAR OF CHASSIS
NVRAM SWITCH LOCATED
BEHIND CIRCULATION VENT
Figure 2-2 NVRAM Switch Location
149005
MicroMMAC Installation Guide Page 2-9
CHAPTER 3
INSTALLATION
This chapter provides instructions for the following:
• Unpacking the MicroMMAC
• Removing the MicroMMAC chassis cover
• Setting the mode switches
• Adding/Replacing EPIMs
• Testing the MicroMMAC
Only qualified personnel should perform installation procedures.
3.1 UNPACKING THE MicroMMAC
Unpack the MicroMMAC as follows:
1. Remove the shipping material covering the MicroMMAC.
2. Carefully remove the MicroMMAC from the shipping box and set it aside to prevent damage.
3. Visually inspect the MicroMMAC. If there are any signs of damage, contact Cabletron Systems Technical Support immediately.
4. Read the MicroMMAC Release Notes included in the shipping box.
NOTE
Cabletron Systems includes 3-1/2" disks with the MicroMMAC that contain a backup copy of the MicroMMAC FLASH
Firmware Image File. Download the file to the MicroMMAC if the existing image becomes corrupted.
MicroMMAC Installation Guide Page 3-1
Chapter 3: Installation
3.2 REMOVING THE CHASSIS COVER
This section describes how to remove the chassis cover of the
MicroMMAC . The chassis cover must be removed to install BRIMs or
SIMMs, and to set the mode switch bank. Refer to the applicable BRIM
User’s Guide for installation instructions.
Figure 3-1 shows how to remove the chassis cover and the location of the
BRIM slot. You need a Phillips-head screwdriver to remove the chassis cover.
Do not remove the chassis cover from the MicroMMAC while power is applied to the unit.
Do not power up the MicroMMAC for any reason until the cover and screws are in place. Hazardous voltages are present that could damage the unit or cause personal injury.
!
C AUT IO N
The components and boards associated with the MicroMMAC are sensitive to static discharges. Be sure to use an antistatic wrist strap and observe all static precautions during this procedure. Failure to do so could result in damage to the
MicroMMAC.
To remove the chassis cover, perform the following steps:
1. Disconnect the MicroMMAC from the network as follows: a.
Disconnect the power cord from the rear of the MicroMMAC.
b. Disconnect all network cables attached to the MicroMMAC. Note the ports to which these cables attach.
c.
If the MicroMMAC is rack mounted, remove it from the rack.
Page 3-2 MicroMMAC Installation Guide
Removing the Chassis Cover
2. Use a Phillips-head screwdriver to remove the seven screws that attach the chassis cover to the MicroMMAC. Place the screws aside. See
Figure 3-1.
3. Remove the chassis cover from the MicroMMAC. See Figure 3-1.
MicroMMAC-24E
10BASE-T HUB
WITH LANVIEW®
LINE:
100-125V - 4.0A
200-250V - 2.0A
50/60Hz
SN
SEH-INTERCONNECT
OUT
MicroMMAC-24E
10BASE-T HUB
WITH
LANVIEW®
LINE:
100-125V - 4.0A
200-250V - 2.0A
50/60Hz
SN
SEH-INTERCONNECT
OUT
090830
Figure 3-1 Removing the Chassis Cover Screws
MicroMMAC Installation Guide Page 3-3
Chapter 3: Installation
3.3 SETTING THE MODE SWITCHES
Figure 3-2 shows the location and factory default settings of the mode switches. Check these switches to ensure that they are in the correct position for normal MicroMMAC operation.
MicroMMAC TOP VIEW
ON
OFF
1 2 3 4 5 6 7 8
FRONT PANEL FLASH MEMORY SIMM
090816
Figure 3-2 The MicroMMAC Mode Switches and FLASH SIMM Location
Switch definitions are as follows:
• Switch 1 - Cabletron Systems use only.
• Switch 2 - Cabletron Systems use only.
• Switch 3 - Cabletron Systems use only.
• Switch 4 - Cabletron Systems use only.
• Switch 5 - Cabletron Systems use only.
Page 3-4 MicroMMAC Installation Guide
Setting the Mode Switches
• Switch 6 - Forced Download. Changing the state of this switch (i.e., moving the switch from one position to another) clears download information from NVRAM and forces the MicroMMAC to download an image file from the station acting as the BOOTP/TFTP server of the
MicroMMAC.
–
!
C AUT IO N
DO NOT change the state of Switch 6 unless
–you have a station acting as a BOOTP server, and a tftp server that contains the MicroMMAC image file. The BOOTP server and the tftp server could be different servers.
–you intend to set up a station to act as a BOOTP server for the
MicroMMAC.
After changing the state of this switch, and repowering the device, the
MicroMMAC requests a new image until it either receives a new image, or you reset the MicroMMAC again by using the Reset button on the front panel.
Reset the MicroMMAC a second time. The device attempts to locate a BOOTP server again. However, the BOOTP request times out after about one minute, and the MicroMMAC boots from FLASH memory.
• Switch 7 - Cabletron Systems use only.
• Switch 8 - Password Defaults. Changing the state of this switch clears user-entered passwords stored in NVRAM, and restores default passwords. Once you reset the MicroMMAC, you can use the defaults or re-enter your passwords.
!
C AUT IO N
Do not change the state of Switch 8 unless you want to reset the MicroMMAC user-configured passwords to their factory default settings.
MicroMMAC Installation Guide Page 3-5
Chapter 3: Installation
3.4 UPGRADING THE FLASH SIMM
The MicroMMAC allows memory upgrades for the FLASH EEPROM.
Figure 3-2 shows the location of the FLASH SIMM Slot.
Before you can install the new FLASH SIMM, you need to remove the existing FLASH SIMM.
!
C AUT IO N
The internal components and boards associated with the
MicroMMAC are static sensitive devices. Use the antistatic wrist band and observe standard antistatic safety procedures when the cover is removed. Failure to do so could cause damage or severely limit the life expectancy of the
MicroMMAC.
To remove the FLASH SIMM, refer to Figure 3-3 and perform the following steps:
1. Push the two connector clips away from the FLASH SIMM to release it.
2. Tilt the FLASH SIMM upward.
3. Pull the FLASH SIMM out of the socket.
3
SIMM
2
CONNECTOR CLIP
1
Figure 3-3 Removing a FLASH SIMM
CONNECTOR CLIP
1742-32
Page 3-6 MicroMMAC Installation Guide
Upgrading the FLASH SIMM
To install the replacement FLASH SIMM, refer to Figure 3-4 and perform the following steps:
1. With the SIMM notch positioned as shown in Figure 3-4, gently insert the FLASH SIMM into the SIMM connector.
2. Carefully rock the FLASH SIMM back towards the connector clips until the clips snap into place and secure the FLASH SIMM.
SIMM
NOTCH
CONNECTOR CLIP
2
1
CONNECTOR CLIP
CONNECTOR
Figure 3-4 Installing a FLASH SIMM
1742-33
MicroMMAC Installation Guide Page 3-7
Chapter 3: Installation
3.5 ADDING/REPLACING EPIMS
This section explains how to add/replace an Ethernet Port Interface
Module (EPIM) to upgrade or change the capabilities of the
MicroMMAC.
!
C AUT IO N
EPIMs are sensitive to static discharge. Be sure to use an antistatic wrist strap and observe all static precautions during this procedure. Failure to do so could result in damage to the
EPIM.
To install an EPIM, perform the following steps:
!
C AUT IO N
When removing an EPIM, make sure to pull the module straight out. Failure to do so could result in damage to the connector.
1. Remove the coverplate or the EPIM (whichever applies).
2. Slide the EPIM into place, making sure the connector on the EPIM attaches to the connector inside the MicroMMAC. See Figure 3-5.
3. Install the mounting screw.
Page 3-8
EPIM-2
18X
17X
16X
15X 14X
13X
6X
5X
4X
3X
2X
1X
EPIM-1
LNK
EPIM-T
090828
Figure 3-5 Installing an EPIM
MicroMMAC Installation Guide
Adding/Replacing BRIMs
3.6 ADDING/REPLACING BRIMS
To add or replace a Bridge/Router Interface Module (BRIM) in the
MicroMMAC, refer to the applicable BRIM user’s guide.
3.7 TESTING THE MicroMMAC
Before installing the MicroMMAC in a live network, test the hub in a controlled situation to ensure that it is bridging packets. Perform this test with two workstations as shown in Figure 3-6.
To test the MicroMMAC, perform the following steps:
1. Connect the first workstation to a MicroMMAC network port, EPIM, or BRIM.
2. Connect the second workstation to a MicroMMAC network port,
EPIM, or BRIM.
3. Designate the first workstation as a file server and the second workstation as the client.
NOTE
To configure a workstation as a file server or client, refer to the documentation included with the workstation.
4. Send packets between the two workstations to verify the proper operation of the MicroMMAC.
NOTE
A “ping” test of each workstation verifies that the MicroMMAC is operating properly.
MicroMMAC Installation Guide Page 3-9
Chapter 3: Installation
MicroMMAC-24E 10BASE-T HUB
WITH
LANVIEW
CABLETRON
MicroMMAC-24
RCV
R
LNK
24 23 22 21 20 19 18 17 16 15 14 13
DISPLAY RESET
COM 2 COM 1
PWR
CPU
CLN
RCV
LNK
12 11 10 9 8 7 6 5 4 3 2 1
E
1
E
2 2 4 X 2 3X 2 2 X 2 1 X 2 0 X 19X
12X 11X 10X 9X 8X 7X
18X 17X 16 X 15 X 14 X 13 X
6X 5X 4X 3X 2X 1X
EPIM 2
EPIM 1
CLIENT WORKSTATION
FILE SERVER WORKSTATION
090831
Figure 3-6 Installation Check-Out
3.8 INSTALLING THE MicroMMAC
The MicroMMAC may be installed on a tabletop, shelf, or in a 19-inch rack and may be configured as a standalone or stacked hub. Cabletron
Systems provides an accessory kit with the MicroMMAC that includes rackmount brackets, mounting screws, and a strain-relief bracket.
The following sections provide instructions for stacking the MicroMMAC or installing it as a standalone device. Follow the instructions that are applicable to your installation needs.
Page 3-10 MicroMMAC Installation Guide
Installing the MicroMMAC
3.8.1 Shelf or Tabletop Installation
Before installation, ensure that you locate the MicroMMAC within reach of the network cabling and follow the requirements listed below:
• A single phase grounded power receptacle that meets the power supply requirements listed in Appendix A, Section A.2, Power Supply
Requirements, must be located within seven feet of the
MicroMMAC.
• In a shelf installation, the shelf must be able to support 30 pounds of static weight for each device in the stack.
• The temperature for the selected location must maintain a temperature between 5˚C and 40˚C (41˚F and 104˚F), and fluctuate less than 10˚C
(18˚F) per hour.
• There must be sufficient clearance around the unit for proper ventilation.
For a shelf or tabletop installation, locate the MicroMMAC within 7 feet of its power source and with an unrestricted free surface area 21 inches wide, 18 inches deep and 6 inches high, as shown in Figure 3-7.
18 INCHES
6 INCHES
MicroMMAC-24E 10BASE-T HUB
WITH
LANVIEW R
21 INCHES
EPIM 2
EPIM 1
7-FOOT POWER CORD
Figure 3-7 Shelf or Tabletop Installation
090811
MicroMMAC Installation Guide Page 3-11
Chapter 3: Installation
3.8.2 Attaching the Strain-Relief Bracket
To attach the strain-relief bracket to the bottom of the MicroMMAC, perform the following steps:
1. Locate the strain-relief bracket and four 8-32 x 3/8-inch screws from the MicroMMAC-ACCY-KIT package.
Do NOT attempt to attach the strain-relief bracket with screws other than the 8-32 x 3/8-inch screws included with the
MicroMMAC accessory kit. Use of longer screws may damage the unit or cause electrical shock.
2. Attach the strain-relief bracket to the bottom of the MicroMMAC as shown in Figure 3-8.
SCREWS (4)
STRAIN-RELIEF BRACKET
EPIM 1
EPIM 2
MicroMMAC-24E
LANVIEW 10BASE-T HUB
090807
Figure 3-8 Attaching the Strain-Relief Bracket
Page 3-12 MicroMMAC Installation Guide
Installing the MicroMMAC
3.8.3 Rack Mounting the MicroMMAC
Refer to Figure 3-9 and perform the following steps to install the
MicroMMAC in a 19-inch rack.
1. Remove four cover screws (two from each side) located along the front edges of each side of the MicroMMAC.
Do not remove the cover from the MicroMMAC. Do not remove any other screws from the unit.
2. Using the four cover screws removed in step 1, attach the rack mounting brackets to each end of the MicroMMAC.
WALL/RACK MOUNTING
BRACKETS (2)
EPIM 2
MicroMMAC-24E 10BASE-T HUB
WITH
LANVIEW
R
EPIM 1
SCREWS (4)
090808
Figure 3-9 Installing the Rackmount Brackets
3. Ensure that the rack used to install the unit will support the unit and that the rack will remain stable with the unit installed in it. Support the
MicroMMAC securely from underneath and align the brackets of the
MicroMMAC chassis with the screw holes in the equipment rack as shown in Figure 3-10. Fasten the MicroMMAC to the 19-inch rack securely.
!
C AUT IO N
The cooling fans at the rear panel of the MicroMMAC must have adequate clearance (two inches on either side and in
the rear) for unrestricted air flow.
MicroMMAC Installation Guide Page 3-13
Chapter 3: Installation
19-INCH RACK
MicroMMAC-24E 10BASE-T HUB
WITH
LANVIEW
R
EPIM 2
EPIM 1
Figure 3-10 Installing the MicroMMAC in the Rack
3.8.4 Stacking the MicroMMAC
The rear panel of the MicroMMAC has an Interconnect Bus Out Port
(male connector) for stackable connections. To attach non-intelligent hubs to the MicroMMAC, use Cabletron Systems HubSTACK Interconnect cables. Table 3-1 describes each cable.
Part Number
9380110
9380111
Table 3-1 HubSTACK Interconnect Cables
Description
12” HubSTACK Interconnect
Cable
18” HubSTACK Interconnect
Cable
Application
SEH to SEH connections
MicroMMAC to SEH connections
To stack the MicroMMAC together with an SEH non-intelligent hub, perform the following steps:
1. Attach the MicroMMAC HubSTACK Interconnect cable to the OUT port on the rear panel of the MicroMMAC as shown in Figure 3-11.
2. Attach the other end of the MicroMMAC HubSTACK Interconnect cable to the IN port on the rear panel of the SEH.
Page 3-14 MicroMMAC Installation Guide
Installing the MicroMMAC
To stack SEH non-intelligent hubs together, perform the following steps:
1. Attach the SEH HubSTACK Interconnect cable to the OUT port on the rear panel of the SEH as shown in Figure 3-11.
2. Attach the other end of the SEH HubSTACK Interconnect cable to the
IN port on the rear panel of the SEH next in the stack.
SEH HubSTACK
INTERCONNECT CABLES (PN 9380110)
HubSTACK 10BASE-T
HUB
WITH
LANVIEW®
SEH-24
OUT SEH INTERCONNECT
HubSTACK 10BASE-T
HUB
SEH-24
WITH
LANVIEW®
IN
OUT SEH INTERCONNECT IN
HubSTACK 10BASE-T
HUB
WITH
LANVIEW®
SEH-24
OUT
SEH INTERCONNECT IN
HubSTACK 10BASE-T
HUB
WITH
LANVIEW®
SEH-24
OUT SEH INTERCONNECT IN
MicroMMAC-34E 10BASE-T
HUB
WITH
LANVIEW®
LINE:
100-125V - 4.0A
200-250V - 2.0A
50/60Hz
SN
MicroMMAC HubSTACK
INTERCONNECT CABLE (PN 9380111)
SEH INTERCONNECT
OUT
090805
Figure 3-11 Stacking the MicroMMAC
MicroMMAC Installation Guide Page 3-15
Chapter 3: Installation
If you temporarily disconnect one end of a HubSTACK Interconnect cable and leave the other end attached to the hub, ensure that you disconnect the cable from the OUT port as shown in Figure 3-12. This ensures proper termination of the HubSTACK cable.
DISCONNECT MicroMMAC AND SEH
INTERCONNECT CABLES AT THE "OUT" PORT.
HubSTACK
10BASE-T HUB
WITH
LANVIEW®
SEH-24
OUT SEH INTERCONNECT IN
HubSTACK 10BASE-T HUB
WITH
LANVIEW®
SEH-24
OUT SEH INTERCONNECT IN
MicroMMAC-34E 10BASE-T HUB
WITH
LANVIEW®
LINE:
100-125V - 4.0A
200-250V - 2.0A
50/60Hz
SN
SEH INTERCONNECT
OUT
090806
Figure 3-12 Disconnecting the HubSTACK Interconnect Cable
Page 3-16 MicroMMAC Installation Guide
CHAPTER 4
CONNECTING TO THE NETWORK
This chapter explains how to connect the MicroMMAC to a network using the network ports and EPIMs.
4.1 CONNECTING THE MicroMMAC TO THE NETWORK
The procedure for connecting network segments to the MicroMMAC varies depending on the media and ports being connected. Refer to the following list and perform the procedure described in the subsections that apply to your MicroMMAC:
Connecting a 10BASE-T Segment to the
MicroMMAC-22E and MicroMMAC-24E
Connecting a 10BASE-T Segment to the
MicroMMAC-32E and MicroMMAC-34E
Connecting a 10BASE-T Segment to an EPIM-T
Section 4.1.1
Section 4.1.2
Section 4.1.3
Connecting a 10BASE-F Segment to an EPIM-F1 Section 4.1.4
Connecting a 10BASE-F Segment to an EPIM-F2 or EPIM-F3
Section 4.1.5
Connecting a 10BASE2 Segment to an EPIM-C
Connecting an AUI Segment to an EPIM-A
Connecting an AUI Segment to an EPIM-X
Section 4.1.6
Section 4.1.7
Section 4.1.8
MicroMMAC Installation Guide Page 4-1
Chapter 4: Connecting to the Network
4.1.1 Connecting a 10BASE-T Segment to the
MicroMMAC-22E and MicroMMAC-24E
The MicroMMAC-22E and MicroMMAC-24E have RJ45 network ports that support unshielded twisted pair segments. Each RJ45 port on the
MicroMMAC incorporates a Polarity Detection and Correction feature.
The Polarity Detection and Correction feature allows the MicroMMAC to pass data regardless of the polarity of the twisted pair segment’s receive link. Cabletron Systems does not recommend operating in this condition and if this condition is discovered, the segment should be removed from the network and wired correctly by a technician.
To attach twisted pair segments to the RJ45 network ports of the
MicroMMAC, perform the following steps:
1. Insert the RJ45 connector from each twisted pair segment into the desired network port on the MicroMMAC. See Figure 4-1.
18X
17X
16X
15X 14X
13X
6X
5X
4X
3X
2X
1X
EPIM-2
LNK
EPIM-T
EPIM-1
LNK
EPIM-T
090812
Figure 4-1 MicroMMAC-22E/24E Network Ports
2. Check that the associated LNK LED for the port is on. If the LED is not on, perform each of the following steps until it is: a.
Check that the 10BASE-T device at the other end of the twisted pair segment is powered up.
b. Verify that the RJ45 connector on the twisted pair segment has the proper pinouts. Refer to Figure 4-4.
Page 4-2 MicroMMAC Installation Guide
Connecting the MicroMMAC to the Network c.
Check that the twisted pair connection meets dB loss and cable specifications outlined in Appendix C, Network Planning and
Configuration.
If a link still has not been established, contact Cabletron Systems
Technical Support.
4.1.2 Connecting a 10BASE-T Segment to the
MicroMMAC-32E and MicroMMAC-34E
The MicroMMAC-32E has one RJ71 connector and the
MicroMMAC-34E has two RJ71 connectors. Each RJ71 connector supports twelve 10BASE-T segments.
NOTE
Refer to Appendix C, Network Planning and Configuration, for RJ71 pinouts.
To connect the MicroMMAC in an existing twisted pair wiring system, perform the following steps:
1. Connect an RJ71 connector to an RJ71 port on the MicroMMAC as shown in Figure 4-2.
13X
1X
EPIM-2
LNK
EPIM-T
EPIM-1
LNK
EPIM-T
24X
12X
090813
Figure 4-2 MicroMMAC-32E/34E Network Ports
MicroMMAC Installation Guide Page 4-3
Chapter 4: Connecting to the Network
2. Attach wires of the 25-pair cable to a punch down block, or patch panel.
3. At the device end of a segment, attach the segment to a 10BASE-T compliant Ethernet device.
4. Check that the link LED on the 10BASE-T Ethernet device and the applicable LNK LEDs on the MicroMMAC are on. If the LEDs are not on, perform each of the following steps until the LEDs are on: a.
Check that the 10BASE-T device and the MicroMMAC have power.
b. Verify the cabling between the MicroMMAC and the 10BASE-T device.
c.
Check the cable for continuity.
If a link has not been established, contact Cabletron Systems Technical
Support.
Page 4-4 MicroMMAC Installation Guide
Connecting the MicroMMAC to the Network
4.1.3 Connecting a 10BASE-T Segment to an EPIM-T
Before connecting a segment to the EPIM-T, check each end of the segment to determine the proper crossover. If the wires do not cross over, use the switch on the EPIM-T to internally cross over the RJ45 port. Refer to Figure 4-3 to properly set the EPIM-T crossover switch.
POSITION X
(CROSSED OVER)
1. RX+
2. RX-
3. TX+
4. NC
5. NC
6. TX-
7. NC
8. NC
POSITION =
(NOT CROSSED OVER)
1. TX+
2. TX-
3. RX+
4. NC
5. NC
6. RX-
7. NC
8. NC
149014
Figure 4-3 EPIM-T Crossover Switch
To connect an EPIM-T to a twisted pair segment, perform the following steps:
1. Connect the twisted pair segment to the module by inserting the RJ45 connector on the twisted pair segment into the RJ45 port on the module. See Figure 4-3.
2. Check that the EPIM’s LNK LED is on. If the LED is not on, perform each of the following steps until it is: a.
Check that the 10BASE-T device at the other end of the twisted pair segment is powered up.
MicroMMAC Installation Guide Page 4-5
Chapter 4: Connecting to the Network b. Verify that the RJ45 connector on the twisted pair segment has the proper pinouts. Refer to Figure 4-4.
MicroMMAC
RJ45 PORT
PIN 1 Tx+
PIN 2 Tx-
PIN 3 Rx-
PIN 4 Rx+
10BASE-T
DEVICE PORT
RX+/RX- AND TX+/TX- MUST SHARE A COMMON PAIR.
Tx+ PIN 1
Tx- PIN 2
Rx- PIN 3
Rx+ PIN 6
090833
Figure 4-4 Cable Pinouts RJ45 Port c.
Check the cable for continuity.
d. Check that the twisted pair connection meets dB loss and cable specifications outlined in Appendix C.
e.
Check that the crossover switch is in the correct position.
If a link still has not been established, contact Cabletron Systems
Technical Support.
4.1.4 Connecting a 10BASE-F Segment to an EPIM-F1
!
C AUT IO N
When connecting a fiber optic link segment with SMA 906 connectors to an EPIM-F1 with SMA ports, make sure each connector uses half alignment, NOT full alignment, sleeves. A full alignment sleeve damages the receive port. SMA 905 connectors do not need alignment sleeves.
Each fiber optic link consists of two strands of fiber optic cabling: the transmit (TX) and the receive (RX). The transmit strand from a module port connects to the receive port of a fiber optic Ethernet device at the other end of the segment. The receive strand of the applicable port on the module connects to the transmit port of the fiber optic Ethernet device.
Page 4-6 MicroMMAC Installation Guide
Connecting the MicroMMAC to the Network
Cabletron Systems recommends labeling fiber optic cables to indicate receive and transmit ends. Many cables are prelabeled, providing matching labels or tapes at both ends of each strand of cable.
1. Remove the protective plastic covers from the fiber optic ports on the applicable port on the module, and from the ends of the connectors on each fiber strand.
!
C AUT IO N
Do not touch the ends of the fiber optic strands, and do not let the ends come in contact with dust, dirt, or other contaminants.
Contamination of cable ends causes problems in data transmissions. If necessary, clean contaminated cable ends using alcohol and a soft, clean, lint-free cloth.
2. Attach one fiber to the receive port (RX) on the EPIM-F1. Insert the
SMA connector into the port. Turn the connector clockwise until the connector will no longer turn easily. Do not overtighten the connector.
109814
Figure 4-5 SMA Connector Insertion
3. Attach the other fiber of the pair to the applicable transmit port on the module. Use the same procedure for insertion of the ST connector.
MicroMMAC Installation Guide Page 4-7
Chapter 4: Connecting to the Network
4. At the other end of the fiber optic cable, attach the fiber pair to the transmit and receive ports of the device.
If link indicators are present for the fiber optic connection, check that they are ON. If an indicator is present but not ON, that port does not have a valid link. Perform each of the following steps until you reach a resolution of the problem and achieve a link.
• Check that the device at the other end of the link is ON.
• Verify proper cross-over of the fiber strands. Try swapping the transmit and receive connections at only one end of the link.
• Verify that the fiber connection meets the dB loss specifications outlined in Appendix C, Network Planning and Configuration.
If you are still unable to establish a link, attempt to make the connection between the devices with another fiber optic cable. If this is unsuccessful, contact Cabletron Systems Technical Support.
4.1.5 Connecting a 10BASE-F Segment to an EPIM-F2 or
EPIM-F3
Each fiber optic link consists of two strands of fiber optic cabling: the transmit (TX) and the receive (RX). The transmit strand from a module port connects to the receive port of a fiber optic Ethernet device at the other end of the segment. The receive strand of the applicable port on the module connects to the transmit port of the fiber optic Ethernet device.
Cabletron Systems recommends labeling fiber optic cables to indicate receive and transmit ends. Many cables are prelabeled, providing matching labels or tapes at both ends of each strand of cable.
1. Remove the protective plastic covers from the fiber optic ports on the applicable port on the module, and from the ends of the connectors on each fiber strand.
Page 4-8 MicroMMAC Installation Guide
Connecting the MicroMMAC to the Network
!
C AUT IO N
Do not touch the ends of the fiber optic strands, and do not let the ends come in contact with dust, dirt, or other contaminants.
Contamination of cable ends causes problems in data transmissions. If necessary, clean contaminated cable ends using alcohol and a soft, clean, lint-free cloth.
2. Attach one fiber to the applicable receive port on the module. Insert the ST connector into the port with the alignment slot on the connector inserted over the locking key on the port. Turn the connector clockwise to lock it down.
Figure 4-6 ST Connector Insertion
090834
3. Attach the other fiber of the pair to the applicable transmit port on the module. Use the same procedure for insertion of the ST connector.
4. At the other end of the fiber optic cable, attach the fiber pair to the transmit and receive ports of the device.
If link indicators are present for the fiber optic connection, check that they are ON. If an indicator is present but not ON, that port does not have a valid link. Perform each of the following steps until you reach a resolution of the problem and achieve a link.
• Check that the device at the other end of the link is ON.
• Verify proper cross-over of the fiber strands. Try swapping the transmit and receive connections at only one end of the link.
MicroMMAC Installation Guide Page 4-9
Chapter 4: Connecting to the Network
• Verify that the fiber connection meets the dB loss specifications outlined in Appendix C, Network Planning and Configuration.
If you are still unable to establish a link, attempt to make the connection between the devices with another fiber optic cable. If this is unsuccessful, contact Cabletron Systems Technical Support.
4.1.6 Connecting a 10BASE2 Segment to an EPIM-C
To connect a 10BASE2 thin coaxial segment to an EPIM-C, perform the following steps:
NOTE
Before attaching a male BNC connector to a female BNC barrel connector or terminator, look into the end of the connector to verify that the gold contact pin is present and centered. Any bent or broken pins may not connect properly and should be replaced.
1. Set the Internal Termination (TERM) Switch, located to the right of the port and labeled TERM to one of the following settings: a.
ON position ( ) to internally terminate the thin coaxial cable segment at the port. Thin coaxial cable segments may be directly connected to the port.
b. OFF position ( ) to not internally terminate the thin coaxial cable segment at the port. Segments may only be connected through
T-connectors which are connected to properly terminated segments on both ends.
NOTE
Failure to terminate each T-connector segment may result in improper segment operation. Place a terminator on any open female connection on the T-connector.
c.
Attach another thin coaxial cable segment or a terminator to the other female connector on the T-connector.
Page 4-10 MicroMMAC Installation Guide
Connecting the MicroMMAC to the Network
2. Align the guide channels of the BNC (male) metal housing with the locking keys of the BNC barrel (female) connector on the EPIM. Slide the metal housing of the male connector straight over the metal housing of the female connector.
3. Once the housing stops moving in, turn the metal housing clockwise while continuing to apply light forward pressure.
149016
Figure 4-7 BNC Connector Insertion
4. The locking keys of the female connector will pull the connector in until they reach the circular locking holes at the end of the guide channels. The keys will click the connector into place and hold it there.
To remove the BNC connector, perform the steps above in reverse order, turning the metal housing counter-clockwise and pulling the connector straight off of the female BNC connector.
4.1.7 Connecting an AUI Segment to an EPIM-A
!
C AUT IO N
Ensure that the external transceiver to which the EPIM-A connects does not have the Signal Quality Error (SQE or
“heartbeat”) test function enabled. The EPIM does not operate if the transceiver has the SQE test function enabled. Refer to the applicable transceiver manual for additional information.
MicroMMAC Installation Guide Page 4-11
Chapter 4: Connecting to the Network
To connect an EPIM-A to an external network segment, perform the following steps:
1. Attach an AUI cable, no longer than 50 meters in length, to the external transceiver.
2. Align the DB15 connector of the AUI cable with the AUI port of the
EPIM as shown in Figure 4-8. The port will only connect if it is properly aligned.
3. Firmly press the AUI connector over the AUI port. If there is a slide latch present for the AUI connector, slide it over the locking posts on the DB15 port.
090814
Figure 4-8 The EPIM-A
If the transceiver PWR LED is OFF with the AUI cable connected: a.
Check the AUI connections for proper pinouts.
b. Check the cable for continuity.
c.
Reconnect the AUI cable to the MicroMMAC and the device.
If the transceiver PWR LED remains OFF, contact Cabletron Systems
Technical Support.
Page 4-12 MicroMMAC Installation Guide
Connecting the MicroMMAC to the Network
4.1.8 Connecting an AUI Segment to an EPIM-X
!
C AUT IO N
The Signal Quality Error (SQE) switch remains in the OFF position for most network connections. However, some Data
Terminal Equipment (DTE) requires SQE. Refer to your DTE manual for SQE requirements.
To connect an EPIM-X to a device not requiring SQE perform the following steps:
1. Align the DB15 connector of the AUI cable with the AUI port of the
EPIM as shown in Figure 4-9. The port will only connect if it is properly aligned.
ON POSITION
(TOWARD BACK
OF EPIM)
ON
OFF
OFF POSITION
(TOWARD FRONT
OF EPIM)
149018
Figure 4-9 The EPIM-X
2. Firmly press the AUI connector over the AUI port. If there is a slide latch present for the AUI connector, slide it over the locking posts on the DB15 port.
3. Check that the SQE LED on the EPIM-X is off. If the SQE LED is on, check the position of the SQE switch.
MicroMMAC Installation Guide Page 4-13
Chapter 4: Connecting to the Network
NOTE
If the SQE LED remains on, even though the SQE switch is in the OFF position, contact Cabletron Systems Technical
Support.
Page 4-14 MicroMMAC Installation Guide
CHAPTER 5
TROUBLESHOOTING
This chapter describes how to use the front panel LANVIEW LEDs to troubleshoot physical layer network problems.
5.1 USING LANVIEW
LANVIEW is Cabletron Systems built-in visual diagnostic and status monitoring system. You can quickly scan the LANVIEW LEDs to observe network status or diagnose network problems, and determine which node or segment is faulty. Figure 5-1 shows the location and provides a brief definition of each LED. A detailed description of each
LED follows Figure 5-1.
MicroMMAC-24E
10BASE-T HUB
WITH
LANVIEW R
DISPLAY RESET
COM 2 COM 1
RCV
LNK
24 23 22 21 20 19 18 17 16 15 14 13
E
2
PWR
CPU
CLN
RCV
LNK
12 11 10 9 8 7 6 5 4 3 2 1
E
1
LED NAME
PWR
(Power)
CPU
(Central Processing Unit)
CLN
(Collision)
RCV
(Receive)
LNK
(Link)
LED COLOR
Off
Green (Solid)
Off
Green (Flashing)
Green (Blinking)
Red (Solid)
Orange (Blinking)
Red
Off
Yellow (Flashing)
Off
Green
Off
DEFINITION
No Power
Power
CPU in BOOT Process
CPU Initializing
CPU Functioning
CPU Not Functioning
Ethernet Interface in stand-by condition
Collision
No Collision
MicroMMAC is Receiving Data
No Activity
Link Established
No Link
090817
Figure 5-1 LANVIEW LEDs
MicroMMAC Installation Guide Page 5-1
Chapter 5: Troubleshooting
PWR
The PWR LED indicates the power status of the MicroMMAC. A green
LED indicates that the MicroMMAC is receiving power. If this LED is off, it indicates a loss of input power. Check the input power source
(circuit breaker, fuse, etc.). If the proper source power is present, the problem could be with the MicroMMAC.
CPU
The CPU LED indicates the operational status of the MicroMMAC processor. This LED alternates from red, to flashing green, to yellow during power-up. If a BRIM is installed, this LED blinks orange for approximately 30 seconds after the boot is complete. This indicates that the front panel Ethernet interface is in a standby condition.
A blinking green LED indicates normal operation. A red LED indicates a faulty processor.
CLN
The CLN LED indicates the collision status of the MicroMMAC ports. A red LED indicates that a collision has occurred on one of the
MicroMMAC ports.
RCV
The RCV LED indicates the receive status of the MicroMMAC ports. A flashing yellow LED indicates that the MicroMMAC is receiving data packets from the associated port segment. Each MicroMMAC port has a corresponding RCV LED:
• Network Ports: RCV LEDs 1–24
• EPIM-1: RCV LED E1
• EPIM-2: RCV LED E2
LNK
The LNK LED indicates the link status of the MicroMMAC ports. A green LED indicates an established link between the associated port segment and the 10BASE-T device at the other end of the segment. LNK
LEDs remain on as long as a link is maintained. Each Network Port (ports
1–24) has a corresponding LNK LED.
Page 5-2 MicroMMAC Installation Guide
Troubleshooting Checklist
5.2 TROUBLESHOOTING CHECKLIST
If your MicroMMAC is not operating properly, Table 5-1 describes some of the problems that may occur, possible causes for the problem, and suggestions for resolving the problem.
Problem
No LEDs on.
Cannot contact the
MicroMMAC from in-band management.
Table 5-1 Troubleshooting Checklist
Possible Causes Recommended Action
Loss of Power.
Improper
Community Names table.
Check that the MicroMMAC has adequate power.
Refer to the MicroMMAC Local
Management User’s Guide for
Community Names Table setup and IP address assignment procedures.
MicroMMAC does not have an IP address.
User-entered parameters (IP address,
Community Names, etc.) are lost when device is powered down.
No power to an external transceiver connected to an
EPIM-A.
No link to device.
NVRAM reset switch has been toggled and user-entered parameters have been reset to the factory default.
AUI cable may be defective.
Transceiver may be defective.
Check the link to the
MicroMMAC.
See Chapter 2 for proper use of the NVRAM switch.
If NVRAM is defective, call
Cabletron Systems Technical
Support.
Replace AUI cable.
Replace transceiver.
High Number of collisions on EPIM ports.
EPIM is defective.
External transceiver has
SQE enabled.
Replace EPIM.
Disable SQE.
MicroMMAC Installation Guide Page 5-3
APPENDIX A
MicroMMAC SPECIFICATIONS
This appendix lists the operating specifications for the MicroMMAC.
Cabletron Systems reserves the right to change these specifications at any time without notice.
A.1 OPERATING SPECIFICATIONS
System Specifications
Shared Memory:
Internal Processor:
Ethernet Controller:
Non-Volatile RAM:
EPROM:
FLASH Memory:
CPU Memory:
4 MB Expandable
Intel 80960 running at 24 MHz
1 National Semiconductor DP93932
128 kB with battery backup
128 kB
2 MB Expandable
4 MB Expandable
A.2 POWER SUPPLY REQUIREMENTS
The MicroMMAC has a universal power supply. Table A-1 lists the input power requirements.
Voltage Range
120 to 125 VAC
Table A-1 Input Power Requirements
Input Current
4.0 A max
Frequency Range
50 to 60 Hz
The power supply has two outputs of +5 volts and +12 volts. The maximum output power is 125 watts and the minimum efficiency is 65% under all conditions of line at full load. Table A-2 lists the minimum and maximum load current from each output.
MicroMMAC Installation Guide Page A-1
Appendix A: MicroMMAC Specifications
Output
+5 Volts
+12 Volts
Table A-2 Power Supply Output Specifications
Minimum Load Maximum Load Maximum Power
1.00 Amps
0.15 Amps
15 Amps
4 Amps
75 Watts
48 Watts
A.3 ENVIRONMENTAL REQUIREMENTS
Operating Temperature: 5
°
C to 40
°
C (41
°
F to 104
°
F)
Storage Temperature: -30
°
C to 90
°
C (-22
°
F to 194
°
F)
Operating Humidity: 5% to 95% (non-condensing)
A.4 AGENCY APPROVALS
This unit meets the safety requirements of UL 1950, CSA C22.2 No. 950,
EN 60950, and IEC 950.
A.5 EMI REQUIREMENTS
This unit meets the EMI requirements of FCC Part 15 Class A, EN 55022
Class A, and VCCI Class I.
A.6 EMC REQUIREMENTS
This unit meets the EMC requirements of EN 50082-1.
A.7 PHYSICAL SPECIFICATIONS
Dimensions: 2.8H x 17.0W x 13.5D in
(7.2 x 43.6 x 34.6 cm)
Weight (unit): 7 lb
Page A-2 MicroMMAC Installation Guide
APPENDIX B
EPIM SPECIFICATIONS
EPIMs allow the MicroMMAC to attach to the main network using a variety of media types. Cabletron Systems offers a variety of EPIMs. The following sections provide specifications for each EPIM.
B.1 EPIM-T
The EPIM-T is an RJ45 connector that supports unshielded twisted pair cabling. It has an internal Cabletron Systems TPT 10BASE-T Twisted
Pair Transceiver.
The slide switch on the EPIM-T determines the crossover status of the cable pairs. If the switch is on the X side, the pairs are internally crossed over. If the switch is on the = side, the pairs are not internally crossed over. Figure B-1 shows the pinouts for the EPIM-T in both positions.
Position X
(crossed over)
1. RX+
2. RX-
3. TX+
4. NC
5. NC
6. TX-
7. NC
8. NC
Position =
(not crossed over)
1. TX+
2. TX-
3. RX+
4. NC
5. NC
6. RX
7. NC
8. NC
Figure B-1 Crossover Switch on the EPIM-T
149029
MicroMMAC Installation Guide Page B-1
Appendix B: EPIM Specifications
B.2 EPIM-F1 AND EPIM-F2
The EPIM-F1 and EPIM-F2 shown in Figure B-2 support multimode fiber optic cabling. Each EPIM has an internal Cabletron Systems FOT-F fiber optic transceiver. The EPIM-F1 is equipped with SMA connectors and the EPIM-F2 is equipped with ST connectors.
149030
Figure B-2 The EPIM-F1 and EPIM-F2
149031
Parameter
Table B-1 EPIM-F1 and EPIM-F2 Specifications
Typical
Value
Worst Case Worst
Case
Budget
Typical
Budget
Receive
Sensitivity
-30.5 dBm
Peak Input Power -7.6 dBm
-28.0 dBm
-8.2 dBm
Transmitter Power
50/125
µ m Fiber
62.5/125
µ m
Fiber
-13.0 dBm
-10.0 dBm
100/140
µ m Fiber -7.0 dBm
Error Rate
-15.0 dBm
-12.0 dBm
-9.0 dBm
Better than 10 -10
–
–
13.0 dB
16.0 dB
19.0 dB
–
–
17.5 dB
20.5 dB
23.5 dB
Page B-2 MicroMMAC Installation Guide
EPIM-F3
The transmitter power and receive sensitivity levels listed in Table B-1 represent Peak Power Levels after optical overshoot. You must use a Peak
Power Meter to correctly compare the above values to those you measure on any particular port. If you measure Power Levels with an Average
Power Meter, you must add 3 dBm to the measurement to correctly compare measured values to the values listed in Table B-1
(e.g., -29.5 dBm peak = -32.5 dBm average).
B.3 EPIM-F3
Figure B-3 shows the EPIM-F3. The EPIM-F3 supports single mode fiber optic cabling. It has an internal Cabletron Systems FOT-F fiber optic transceiver and is equipped with ST Connectors.
Figure B-3 EPIM-F3
149032
Transmitter power is inversely proportional to temperature rise. Use the
Output Power Coefficient to calculate increased or decreased power output for your operating environment. For example, typical power output at 25˚C equals -16.4 dBm. For a 4˚C temperature increase, multiply the typical coefficient (-0.15 dBm) by four, and add the result to typical output power (4 x -0.15 dBm + -16.4 dBm = -17.0 dBm).
MicroMMAC Installation Guide Page B-3
Appendix B: EPIM Specifications
Parameter
Transmitter Peak
Wave Length
Spectral Width
Rise Time
Fall Time
Duty Cycle
Bit Error Rate
Table B-2 EPIM-F3 Specifications
Typical Value Minimum
1300 nm
60 nm
3.0 ns
2.5 ns
50.1%
Better than 10 -10
1270 nm
–
2.7 ns
2.2 ns
49.6%
Maximum
1330 nm
100 nm
5.0 ns
5.0 ns
50.7%
The transmitter power levels and receive sensitivity levels listed in
Table B-1 represent Peak Power Levels after optical overshoot. You must use a Peak Power Meter to correctly compare the above values to those you measure on any particular port. If you measure Power Levels with an
Average Power Meter, you must add 3 dBm to the measurement to correctly compare those measured values to the values listed above (e.g.,
-29.5 dBm peak = -32.5 dBm average).
Page B-4 MicroMMAC Installation Guide
EPIM-C
B.4 EPIM-C
The EPIM-C supports thin coaxial cabling and is equipped with an internal Cabletron Systems TMS-3 transceiver. Use the TERM switch on the front of the EPIM-C to set the internal 50 Ohm terminator. This eliminates the need to connect the port to a T-connector and terminator.
Figure B-4 shows the settings for the terminator switch.
TERM
EPIM-C
Internal Termination Switch
= On (internally terminated)
= Off (need external termination)
149034
Figure B-4 EPIM-C
Connector Type
BNC receptacle with gold center contact for use with BNC type
T-connectors and RG58 thin coaxial cable.
Grounding
Connecting a thin coaxial segment to earth ground at more than one point could produce dangerous ground currents.
The BNC port of the EPIM-C is not connected to earth ground.
MicroMMAC Installation Guide Page B-5
Appendix B: EPIM Specifications
B.5 EPIM-A AND EPIM-X
The EPIM-A is a DB15 female connector used to attach segments to an external transceiver. The EPIM-X is equipped with dual internal transceivers. It has a DB15 male connector used to attach segments to an
AUI cable. Figure B-5 shows both modules along with DB15 pinouts.
149035
Figure B-5 EPIM-A and EPIM-X (AUI Port)
Pin 1
2
3
4
7
8
5
6
Logic Ref.
Collision +
Transmit +
Logic Ref.
Receive +
Power Return
No Connection
Logic Ref.
Connector Shell: Positive Ground
Pin 9 Collision -
10 Transmit -
11 Logic Ref.
12 Receive -
13 Power (+12 Vdc)
14 Logic Ref.
15 No Connection
Page B-6 MicroMMAC Installation Guide
APPENDIX C
NETWORK PLANNING AND CONFIGURATION
This appendix contains general network guidelines. Before attempting to install the MicroMMAC or any additional EPIMs or BRIMs, review the requirements and specifications outlined in this appendix.
!
C AUT IO N
Your network installation must meet the conditions, guidelines, specifications, and requirements included in this appendix to ensure satisfactory performance of this equipment. Failure to follow these guidelines may produce poor network performance.
C.1 NETWORK CABLE REQUIREMENTS
The network ports of the MicroMMAC support 10BASE-T Shielded
Twisted Pair (STP) or Unshielded Twisted Pair (UTP) cabling.
EPIMs support UTP, STP, multimode fiber optic, single mode fiber optic,
AUI, or 10BASE2 thin coaxial cabling. The rear panel Interconnect Bus port supports Cabletron Systems HubSTACK Interconnect cables for stackable applications.
Take care in planning and preparing the network cabling and connections.
The quality of the connections and the length of cables are critical factors in determining the reliability of the network. The following sections describe requirements for each media type.
C.1.1 HubSTACK Interconnect Cable
Attach the MicroMMAC to modules in the stack with the HubSTACK
Interconnect bus cables available only from Cabletron Systems. Refer to
Chapter 1 for cable part numbers.
The rear panel of the MicroMMAC has an Interconnect Bus Out port
(male connector) to stack SEH non-intelligent hubs together. One
MicroMMAC supports a stack of up to four SEH non-intelligent hubs.
MicroMMAC Installation Guide Page C-1
Appendix C: Network Planning and Configuration
C.1.2 10BASE-T UTP and STP Cable
The devices and 10BASE-T twisted pair segments connected to the
MicroMMAC and EPIM-T must meet the IEEE 802.3 specifications listed below:
Length
The IEEE 802.3 10BASE-T standard requires that 10BASE-T devices transmit over a 100 meter (328 foot) link using 22-24 AWG unshielded twisted pair wire. However, cable quality largely determines maximum link length. With high quality, low attenuation cable, link lengths of up to
200 meters are achievable. Cable delay limits maximum link length to
200 meters, regardless of the cable type. Cabletron Systems does not recommend UTP cable lengths of more than 100 meters.
NOTE
Losses introduced by connections at punch-down blocks and other equipment reduce total segment length. For each connector or patch panel in the link, subtract 12 meters from the total length of your cable.
Insertion Loss
The maximum insertion loss allowed for a 10BASE-T link is 11.5 dB between frequencies of 5.0 and 10 MHz. This includes the attenuation of the cables, connectors, patch panels, and reflection losses due to impedance mismatches in the link segment.
Impedance
Cabletron Systems 10BASE-T products work on twisted pair cable with
75 to 165 ohms impedance. Unshielded twisted pair cables typically have an impedance of between 85 to 110 ohms.
Shielded twisted pair cables, such as IBM Type 1 cable, are also used. The impedance of IBM Type 1 cable is typically 150 ohms. Higher impedance increases signal reflection, but because the cable is shielded, signal reflection has little effect on the quality of the received signal due to the lack of crosstalk between the shielded cable pairs.
Page C-2 MicroMMAC Installation Guide
Network Cable Requirements
Jitter
Intersymbol interference and reflections can cause jitter in the bit cell timing, resulting in data errors. A 10BASE-T link must not generate more than 5.0 ns of jitter. If the cable meets the impedance requirements for a
10BASE-T link, jitter should not be a concern.
Delay
The maximum propagation delay of a 10BASE-T link segment must not exceed 1000 ns This 1000 ns maximum delay limits the maximum link segment length to no greater than 200 meters.
Crosstalk
Signal coupling between different cable pairs within a multi-pair cable bundle causes crosstalk. 10BASE-T transceiver design alleviates concerns about crosstalk, provided the cable meets all other requirements.
Noise
Crosstalk or externally induced impulses can cause noise. Impulse noise may cause data errors if the impulses occur at very specific times during data transmission. Generally, noise is not a concern. If noise-related data errors are suspected, it may be necessary to either reroute the cable or eliminate the source of the impulse noise.
Temperature
Multi-pair PVC 24 AWG wires typically have an attenuation of approximately 8 to 10 dB/100 meters at 20
°
C (68
°
F). The attenuation of
PVC insulated cable varies significantly with temperature. At temperatures greater than 40
°
C (104
°
F), Cabletron Systems recommends the use of plenum-rated cables to ensure that cable attenuation remains within specification.
MicroMMAC Installation Guide Page C-3
Appendix C: Network Planning and Configuration
C.1.3 Multimode Fiber Optic Cable
Table C-1 shows Multimode Fiber Optic Cable specifications for the
EPIM-F1 and EPIM-F2.
Table C-1 Multimode Fiber Optic Cable Specifications
Attenuation Maximum Cable Length Cable Type
50/125
µ m
62.5/125
µ m
100/140
µ m
13.0 dB or less
16.0 dB or less
19.0 dB or less
The maximum allowable fiber optic cable length is 2 km (2187.2 yards). However, IEEE 802.3
FOIRL specifications specify a maximum of 1 km (1093.6 yards).
Attenuation
Test the fiber optic cable with a fiber optic attenuation test set adjusted for an 850 nm wavelength. This test verifies that the signal loss in a cable is within an acceptable level. Table C-1 shows the attenuation for each multimode cable type.
Fiber Optic Budget and Propagation Delay
When determining the maximum fiber optic cable length to incorporate fiber runs into the network, calculate and consider the fiber optic budget
(a total loss of 10.0 dB or less is permissible between stations) and total network propagation delay.
To determine the fiber optic budget, combine the optical loss due to the fiber optic cable, in-line splices, and fiber optic connectors. Typical loss for a splice and connector (together) equals 1 dB or less.
Propagation delay is the amount of time it takes data to travel from the sending device to the receiving device. Total propagation delay allowed for the entire network is 25.6
µ s in one direction (51.2
µ s round trip). If the total propagation delay between any two nodes on the network exceeds 25.6
µ s, then bridges must be used.
Page C-4 MicroMMAC Installation Guide
Network Cable Requirements
C.1.4 Single Mode Fiber Optic Cable
Table C-2 shows single mode fiber optic cable specifications for the
EPIM-F3.
Table C-2 Single Mode Fiber Optic Cable Specifications
Cable Type
8/125-12/125
µ m
Attenuation
10.0 dB or less
Maximum Cable Length
The maximum allowable fiber optic cable length is 5 km (3.1 miles) with bridges at each segment end.
However, IEEE 802.3 FOIRL specifications specify a maximum of 1 km (1093.6 yards).
Attenuation
Test the fiber optic cable with a fiber optic attenuation test set adjusted for an 1300 nm wavelength. This test verifies that the signal loss in a cable falls within the acceptable level of 10.0 dB or less for any given single mode fiber optic link.
Fiber Optic Budget and Propagation Delay
When determining the maximum fiber optic cable length to incorporate fiber runs into the network, calculate and consider the fiber optic budget
(a total loss of 10.0 dB or less is permissible between stations) and total network propagation delay.
To determine the fiber optic budget, combine the optical loss due to the fiber optic cable, in-line splices, and fiber optic connectors. Typical loss for a splice and connector (together) equals 1 dB or less.
Propagation delay is the amount of time it takes data to travel from the sending device to the receiving device. Total propagation delay allowed for the entire network is 25.6
µ s in one direction (51.2
µ s round trip). If the total propagation delay between any two nodes on the network exceeds 25.6
µ s, then bridges must be used.
MicroMMAC Installation Guide Page C-5
Appendix C: Network Planning and Configuration
C.1.5 10BASE2 Thin Coaxial Cable
The following specifications show 10BASE2 thin coaxial cable requirements for the EPIM-C:
Cable Type
50 ohm RG-58A/U type coaxial cable must be used when making up a
10BASE2 thin coaxial cable segment.
Length
The 10BASE2 thin coaxial cable segment must be no longer than 185 meters (203.5 yards).
Terminators
Terminate each end of a 10BASE2 thin coaxial cable segment.
Connectors
A maximum of 29 T-connectors may be used throughout the length of cable segment for host connections. If an excessive number of barrel connectors are used within the cable segment, such as finished wall plates with BNC feed-throughs, then a reduced number of host connections may be required. For special network design, contact Cabletron Systems
Technical Support.
Grounding
For safety, ground only one end of a 10BASE2 thin coaxial cable segment. Do NOT connect EPIM BNC ports to earth ground.
Connecting a 10BASE2 thin coaxial cable segment to earth ground at more than one point could produce dangerous ground currents.
Page C-6 MicroMMAC Installation Guide
Network Port Specifications
C.1.6 AUI Cable
The following specifications show AUI cable requirements for the
EPIM-A and EPIM-X:
AUI Cable
The AUI cable must be IEEE 802.3 type cable.
Length
The AUI Cable must not exceed 50 meters (165 feet) in length. If 28 AWG thin office drop AUI cable is used, then the maximum cable length is limited to 15.24 meters (50 feet).
Grounding
The connector shell of the EPIM-A and the EPIM-X are connected to ground.
C.2 NETWORK PORT SPECIFICATIONS
The MicroMMAC-22E and MicroMMAC-24E network ports use shielded RJ45 connectors that support both STP and UTP cabling. The
MicroMMAC-32E and MicroMMAC-34E use RJ71 connectors for network connections. The following sections provide specifications for each MicroMMAC model.
MicroMMAC Installation Guide Page C-7
Appendix C: Network Planning and Configuration
C.2.1 MicroMMAC-22E and MicroMMAC-24E
Network Ports
The MicroMMAC-22E and MicroMMAC-24E provide RJ45 connections for network connections. Figure C-1 shows the RJ45 pinouts.
1 2 3 4 5 6 7 8
5X 3X 1X
1. Receive + 5. Not Used
2. Receive - 6. Transmit -
3. Transmit + 7. Not Used
4. Not Used 8. Not Used
149003
Figure C-1 RJ45 Network Ports
C.2.2 MicroMMAC-32E and MicroMMAC-34E
Network Ports
The MicroMMAC-32E and MicroMMAC-34E provide RJ71 connectors for network connections as shown in Figure C-2. Table C-3 shows the pinouts for the RJ71 connector.
Pin 25 Pin 1
Pin 50
Figure C-2 MicroMMAC-34E Network Ports
Pin 26
090803
Page C-8 MicroMMAC Installation Guide
Network Port Specifications
Table C-3 RJ71 Champ Connector Pinouts
Pin Signal Wire Color
15
16
17
18
19
20
21
22
23
24
25
8
9
10
11
12
13
14
6
7
4
5
1
2
3
RX 1-
TX 1-
RX 2-
TX 2-
RX 3-
TX 3-
RX 4-
TX 4-
RX 5-
TX 5-
RX 6-
TX 6-
RX 7-
TX 7-
RX 8-
TX 8-
RX 9-
TX 9-
TX 11-
RX 12-
TX 12-
N/C
Blue/White
Orange/White
Green/White
Brown/White
Gray/White
Blue/Red
Orange/Red
Green/Red
Brown/Red
Gray/Red
Blue/Black
Orange/Black
Green/Black
Brown/Black
Gray/Black
Blue/Yellow
Orange/Yellow
Green/Yellow
RX 10Brown/Yellow
TX 10Gray/Yellow
RX 11Blue/Violet
Orange/Violet
Green/Violet
Brown/Violet
Gray/Violet
Pin Signal
40
41
42
43
44
45
46
47
48
49
50
33
34
35
36
37
38
39
26
27
28
29
30
31
32
RX 8+
TX 8+
RX 9+
TX 9+
RX 10+
TX 10+
RX 11+
TX 11+
RX 12+
TX 12+
N/C
RX 1+
TX 1+
RX 2+
TX 2+
RX 3+
TX 3+
RX 4+
TX 4+
RX 5+
TX 5+
RX 6+
TX 6+
RX 7+
TX 7+
Wire Color
White/Blue
White/Orange
White/Green
White/Brown
White/Gray
Red/Blue
Red/Orange
Red/Green
Red/Brown
Red/Gray
Black/Blue
Black/Orange
Black/Green
Black/Brown
Black/Gray
Yellow/Blue
Yellow/Orange
Yellow/Green
Yellow/Brown
Yellow/Gray
Violet/Blue
Violet/Orange
Violet/Green
Brown
Violet/Gray
MicroMMAC Installation Guide Page C-9
Appendix C: Network Planning and Configuration
C.3 COM PORT SPECIFICATIONS
The RJ45 COM ports supports an Uninterruptible Power Supply (UPS) or access to a Local Management console.
NOTE
For instructions about configuring a UPS or Local Management console to the MicroMMAC, refer to the MicroMMAC Local
Management User’s Guide.
These ports support a Digital Equipment Corporation, VT320 terminal or
PC emulation of the VT320 terminal. Figure C-3 shows the pinouts for the COM ports.
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
COM 2 COM 1
COM Port Pinouts (Console Application)
1. Transmit
2. Data Carrier Detect
3. Data Set Ready
4. Receive Data
5. Signal Ground
6. Data Terminal Ready
7. Request To Send
8. Clear To Send
090804
Figure C-3 COM Port Pinouts
C.4 TRANSCEIVER REQUIREMENTS
When connecting an external network segment, using a transceiver, to the
MicroMMAC with an EPIM-A, the following requirements must be met:
• The transceiver or Ethernet Device to which the module will be connected must meet IEEE 802.3 standards, and/or Ethernet Version
1.0 or Version 2.0 standards.
Page C-10 MicroMMAC Installation Guide
Transceiver Requirements
• The Signal Quality Error (SQE) test function on the transceiver must be disabled if you connect it to a repeater or to an Ethernet Version 1.0 device. In addition, some Version 2.0 equipment does not support the
SQE test. Devices that do not support SQE test interpret the SQE test pulse as a collision.
MicroMMAC Installation Guide Page C-11
Numerics
10BASE2 connecting 4-10
10BASE-F connecting 4-6, 4-8
10BASE-T connecting 4-2, 4-3, 4-5
A
Alignment sleeves 4-6
AUI connecting 4-11, 4-13 auto-baud detection 2-3
B
BNC connector usage 4-10
BRIMs adding/replacing 3-9 available 1-8
C
Cable Requirements
10BASE-2 C-6
10BASE-T C-2
AUI C-7
HubSTACK C-1 multimode fiber C-4 single mode fiber C-5
Caution 1-2
Chassis Cover removing 3-2
COM Port Specifications C-10
D
Distributed LAN Monitor
(DLM) 1-5
INDEX
E
EMC Requirements A-2
EMI Requirements A-2
Environmental Requirements operating humidity A-2 operating temperature A-2 storage temperature A-2
EPIM-A B-6
EPIM-C B-5
EPIM-F1 B-2
EPIM-F2 B-2
EPIM-F3 B-3
EPIMs adding/replacing 3-8 available 1-8
EPIM-T B-1
EPIM-X B-6
SQE switch 4-13
F
FLASH SIMM upgrading 3-6
G
Getting Help 1-10
H
HubSTACK Interconnect Cables part numbers 1-9, 3-14
I
Installing
19-inch rack 3-13 shelf or tabletop 3-11 stacking 3-14 strain-relief bracket 3-12
MicroMMAC Installation Guide Index-1
Index
L
LANVIEW LEDs locating 5-1
LCD saved alarm messages 2-4 saved system messages 2-6 static system messages 2-3 unsaved initialization messages 2-5
Local Management 1-4
M
Mode Switches 3-4
N
Note 1-2
NVRAM switch 2-8
P
Physical Specifications dimensions A-2 weight A-2
Ping 3-9
Pinouts
DB15 B-6
RJ21 C-8
RJ45 C-8
Power Supply output specifications A-2 requirements A-1
R
Remote Network Management 1-7
Reset button 2-7
S
Safety Requirements A-2
Signal Quality Error (SQE) C-11
SMA connectors usage 4-6
Specifications A-1
T
T-connector usage 4-10
Tip 1-2
Transceiver Requirements C-10
Troubleshooting Checklist 5-3
U
Uninterruptible Power Supply
(UPS) C-10
W
Warning 1-2
Index-2 MicroMMAC Installation Guide
POWER SUPPLY CORD
The mains cord used with this equipment must be a 2 conductor plus ground type with minimum 0.75 mm square conductors and must incorporate a standard IEC appliance coupler on one end and a mains plug on the other end which is suitable for the use and application of the product and that is approved for use in the country of application.
GERMAN:
Die Netzleitung, die mit diesem Geraet benuetzt wird, soll einen zwei
Leiter mit Erdleiter haben, wobei die Leiter mindestens 0.75 mm sind, mit einer normalen IEC Geraetesteckdose an einem Ende und einem
Geraetestecker am anderen Ende versehen sind, der fuer den
Gebrauch und die Anwendung des Geraetes geeignet und der zum
Benuetzen im Lande der Anwendung anerkannt ist.
SPANISH:
El cable principal de la red eléctrica utilizado con este equipo debe tener 2 conductores y 1 toma de tierra con un mínimo de 0.75 mm2 cada uno y necesita tener un aparato de acoplamiento standard IEC en un extremo y un enchufe para el cable principal de la red eléctrica en el otro extremo, lo cual sea adecuado para el uso y applicación del producto y lo cual sea aprobado para uso en el pais de applicación.
FRENCH:
Le cordon d' alimentation reliant cet appareil au secteur doit obligatoirement avoir deux fils conducteurs de 0.75 mm2 minimum et un fil de terre. It doit également être équipé du côté appareil d'une fiche agrée IEC et du côte secteur, d'une prise adaptée à l'usage du produit et aux normes du pays où l'appareil est utilisé.
Scarica
Pubblicità