TGA1012

PRI MONITORING AND ALARM SIGNALLING SYSTEM

Modular system

1 access per module, 12 modules per Rack and up to 6 Racks per system

PRI E1/G.704 monitoring test set

Continuous local and remote alarms signalling

Flexible management

E1 streams monitoring by remote side

OVERVIEW

The Aethra ® modular system TGA1012 for alarm signalling over E1/G.704

lines, is the best solution for continuous monitoring aimed to carriers, call center, ISPs, public offices and those who need constant monitoring of their lines. The system is modular as the basic unit may be equipped with a variable number of interface modules in order to manage up to a maximum of 12 primary lines. Moreover, these units may be connected in cascade through RS485 serial port, up to a maximum of 6 units for a total number of

72 lines.

In addition to the alarms signalling feature, TGA1012 allows the conversion between interfaces 120 Ohm - 75 Ohm and vice versa, both Network side and Terminal side without any extra piece of hardware.

By using external devices, e.g. the D2000 PRO , it is possible to be connected to one of the access under control and carry out tests over the line both toward the network and toward the terminal, as well as performing a monitor test in high impedance.

Besides, the optional remote management software, will allow you to control the status of the lines connected to TGA1012, reproducing the device accurately on the screen of your PC.

The optional matrix MTX200, will improve the system management allowing remote automatic access switching, in order to monitor and test the problematic lines using just one external test instrument.

FEATURES AT A GLANCE

Exhaustive tests over the disturbed access by using an external device like D2000 PRO

E1 frame alarm signalling

Modular system, up to 72 PRI access under constant monitoring

Integrated impedance adaptation 75 - 120 Ohm

Optional remote management by PC

Optional matrix for automatic access switching to increase the system management power

Technician’s time optimization and money saving

TECHNICAL SPECIFICATIONS

TELECOM INTERFACES

• Primary Rate Access E1 ITU-T (CCITT) Rec.I.431, G.704

ETS 300 011

PROTOCOLS SUPPORTED

• Simulation and monitor* EDSS-1, Q.SIG, 1TR6,

TN1R6 ® , VN4, X.25, X.31,

DASS-2, DPNSS, CorNet ® -N,

-NX, -NQ, -T, PPP, IP, UDP,

Other protocols available by PC V.5.1, V.5.2, NI1, DMS100, 5ESS

* Simulation and monitor features are available with the ISDN

Tester and Analyzer D2000 PRO

CONNECTORS

• Primary access interface

120 Ohm

75 Ohm

Measuring point

Remote control port

TGA box port

RJ45 (ISO 8877)

Microcoax 1.0/2.3

N2 8wires

RJ9, RS485

DB9

ENVIRONMENTAL CHARACTERISTICS

• Dimension

Weight, with 12 modules

Single module

Dimensions (mm)

Power

External AC/DC adapter

N3 19 II standard rack

≈ 9 kg

≈ 180 gr

260 (w) x 440 (l) x 190 (d)

230Vac ±10% @ 50/60 Hz

TEMPERATURE

Storage/Transport

Operating, nominal

Operating, limits

Humidity, non-condensing

- 25 o C to +55 o C

- 0 o C to +45 o C

- 5 o C to +50 o C

≤ 93% RH @ 40 o C

≤ 70% RH @ 50 o C

REFERENCE REGULATION

EMC aspects

User’s Safety Aspects

CE Marking

CEI EN 55022, CEI EN 55022

CEI EN 50082-1

CEI EN 60950

Class B (residential devices)

ALARMS AND ERROR DETECTED

• Alarms from TE and from NT LOS, LFA, AIS, RAI

• Errors from NT AIS64K, CRC ER

MISCELLANEOUS

• Module mode

• LED Test

OPTIONS

• MTX200

• PC108 for Windows TM

TGA box

• SC10BT-2K

Loop to NT, Idle, Active mode

Automatic E1 access switching matrix

Software for remote management

External box with audible and visible warning

External adapter to control the system through 10/100BT

LAN port

Aethra SpA

Telecommunications via Matteo Ricci 10

60020 Ancona - Italy

Telephone +39.071.218981

Fax +39.071.887077

Video 1

Video 2

+39.071.2189160

+39.071.2189701

Email: [email protected] www.aethra.com

Aethra, Inc.

701 Brickell Avenue

Suite 1390

Miami, FL 33131 USA

Telephone +1.305.375.0010

Toll Free (US only) 1.888.4.AETHRA

Fax +1.305.375.0655

Video +1.305.577.3524

Email: [email protected]

Aethra, the Aethra logo and TGA1012 are trademarks, registered trademarks, or service marks of Aethra SpA Telecommunications in Italy, the United States, and/or other countries. All other company and product names may be registered trademarks or trademarks of their respective owners. Information furnished by Aethra SpA Telecommunications and Aethra, Inc. in this datasheet is believed to be accurate. Products sold and licensed by Aethra SpA Telecommunications and Aethra, Inc. are covered by warranty and patent indemnification provisions appearing in its purchase and license agreements. Aethra SpA Telecommunications and Aethra, Inc.

reserve the right to discontinue production and change specifications and prices at any time without notice. Copyright ©2004 Aethra SpA Telecommunications - All rights reserved. Additional regional offices are located on our website: www.aethrausa.com.

For further details about technical specifications please see “Products” on www.aethra.com

Code 071072004GB Rev.1 (10/04)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement