Honeywell CT3595 Owner's Guide
Add to my manuals
24 Pages
Honeywell CT3595 is a programmable thermostat designed to provide total comfort temperature management with its Smart Response™ Technology. It allows you to keep your home at the desired comfort temperature by automatically calculating exactly when to turn on the furnace or air conditioning. This results in significant energy and money savings as the thermostat remembers to adjust the temperature when you leave home or go to sleep. The Honeywell CT3595 comes preprogrammed, but you can also customize the settings to fit your specific needs.
advertisement
Honeywell CT3500/CT3595
PROGRAMMABLE THERMOSTAT
OWNER’S GUIDE
Weekday, Saturday and Sunday
Programmable Heat and/or Cool
Low Voltage (20 to 30 Vac) Thermostat and Wallplate
Model CT3500/CT3595
Para pedir estas instrucciones en español, llame al 1-800-468-1502.
Pour obtenir ce ode demploi en français, composer le 1-800-468-1502.
Table of Contents
Step 1. Prepare for Installation................................................................................................................................................
5
Step 2. Remove Old Thermostat.............................................................................................................................................
6
Step 3. Mount Thermostat Wallplate.......................................................................................................................................
7
Step 4. Wire Wallplate Terminals ............................................................................................................................................
8
Step 5. Install the Batteries .....................................................................................................................................................
9
Step 6. Set Fan Operation Switch........................................................................................................................................... 10
Step 7. Mount the Thermostat ................................................................................................................................................ 11
Step 8. Customize Your Thermostat ....................................................................................................................................... 11
Step 9. Set the Clock .............................................................................................................................................................. 13
Step 10. Programming ............................................................................................................................................................ 14
Step 11. Operating Your Thermostat....................................................................................................................................... 17
Step 12. Set the Fan and System Switches............................................................................................................................ 18
If You Have a Problem ............................................................................................................................................................ 19
Smart Response™ Technology .............................................................................................................................................. 21
Wiring Diagrams ..................................................................................................................................................................... 22
® U.S. Registered Trademark
© 2004 Honeywell International Inc.
All Rights Reserved 69-1199—4
Total comfort temperature management with Smart Response™ Technology.
Congratulations! You made a smart choice by purchasing your new Honeywell thermostat the smart thermostat that;
• Keeps you comfortable by automatically calculating exactly when the furnace or air conditioning should go on to have the house at the desired comfort temperature by the time you wake up or return home.
• Saves the maximum amount of energy and money by automatically remembering to adjust the temperature when you leave home or go to sleep.
• Provides the ultimate in comfort and convenience . It comes preprogrammed. You can use the preprogrammed schedule, or set your own.
This manual answers many of the questions that can arise as you become familiar and comfortable with your
Honeywell thermostat — the state of the art in home comfort controls.
Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.
MERCURY NOTICE
If this thermostat is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Contact your local waste management authority for instructions regarding recycling and the proper disposal of this control, or of an old control containing mercury in a sealed tube.
If you have questions, call Honeywell Customer Care at 1-800-468-1502.
MERCURY
SWITCH
TYPICAL LOCATION OF A MERCURY
SWITCH IN A THERMOSTAT
M10614
69-1199—4 2
DIGITAL DISPLAY
SET CURRENT
DAY/TIME
SETS CURRENT
TIME AND DAY
RUN PROGRAM
RETURNS
THERMOSTAT
TO NORMAL
OPERATING MODE
Run
Program
Set Current
Day/Time
Hold Temp
HOLD TEMP
SETS A HOLD
TEMPERATURE
AND ACTIVATES
VACATION HOLD
FEATURE.
DAY
SETS DAY OF
THE WEEK
TIME / TIME
SETS TIME FORWARD OR BACK
Day
Time
Wake
Heat/Cool
Settings
Set Program
Leave Return
Heat Off Cool
Sleep
System
Fan
On Auto
RAISES TEMPERATURE
SETTING
LOWERS TEMPERATURE
SETTING
DISPLAYS CURRENT
HEAT/COOL
TEMPERATURE SETTING
PROGRAM PERIODS
WAKE/LEAVE/RETURN/SLEEP:
ENTERS PROGRAMMING MODE
SYSTEM SWITCH
SELECTS HEAT/OFF/COOL
FAN SWITCH
SELECTS AUTO/ON
HEAT/COOL SETTING
SWITCHES BETWEEN
HEAT SETPOINTS AND
COOL SETPOINTS
WHILE PROGRAMMING
M18589
3 69-1199—4
DISPLAYS EITHER CURRENT
TIME OF DAY OR PROGRAM TIMES
SHOWS THERMOSTAT IS IN
THE SET DAY/TIME MODE
SHOWS WHEN
THERMOSTAT IS IN THE
PROGRAMMING MODE
SHOWS TEMPERATURE SETTING
CHANGED FOR THIS PROGRAM PERIOD
SHOWS VACATION
HOLD DURATION
SHOWS CURRENT
DAY OR DAYS BEING
PROGRAMMED
SHOWS CURRENT
PROGRAM PERIOD
OR PERIOD BEING
PROGRAMMED
Set Program
Hold for
Em Ht
Set Day/Time Temporary Setting
AM
Aux Ht
Mon TueWedThuFriSatSun Days
WakeLeaveReturnSleep
System
In
Em Heat Off Cool Auto
Recovery
Wait
Filter
Room
Humid
Outdoor
Repl Batt
SHOWS THE TEMPERATURE
DISPLAYED IS THE CURRENT
SET TEMPERATURE
SHOWS THE TEMPERATURE
DISPLAYED IS THE CURRENT
ROOM TEMPERATURE
SHOWS THE BATTERIES ARE
LOW AND MUST BE
REPLACED
SHOWS CURRENT
SYSTEM SWITCH POSITION
HEAT/OFF/COOL
SHOWS THAT THERMOSTAT IS
DISPLAYS EITHER ROOM
OR SET TEMPERATURES
SHOWS SMART RESPONSE IS OFF
CONVENTIONAL RECOVERY IS ON
INFORMATION AND WAITING TO CALL FOR HEAT OR COOL
SHOWS SMART RESPONSE IS
CHANGING THE TEMPERATURE
TO MEET THE CURRENT PROGRAMS
M18590
69-1199—4 4
STEP 1. PREPARE FOR INSTALLATION
!
Check Table 1, the compatibility chart, to make sure the thermostat is compatible with your system. If your system is not compatible, call Honeywell Customer Care, toll-free, 1-800-468-1502.
Table 1. Compatibility Chart.
Gas — Standing Pilot
Gas — Electronic Ignition
Gas-fired Boilers
System Type
Yes
Compatibility with CT3500/CT3595
Yes
Yes a
Yes
Gas — 750 Millivolt Heat Only b
Oil-Fired Boilers
Oil-Fired Furnace
Electric Furnace
Electric Air Conditioning
Baseboard Electric (120/240 line volt) c
Single Stage Heat Pump
Multistage Heat Pumps/Multistage Equipment
Yes
Yes
Yes
Yes
No
Yes
No a a
Compatible with 2-wire Honeywell and Taco zone valves. Not compatible with 3-wire zone valves or 2-wire White
Rodgers no. 1361 zone valves.
b Millivolt system must be heating only.
c
Not compatible with any 120/240 volt system.
Package Contents
• Thermostat
• Wiring labels
Tools Required
• Screwdriver
• Drill
• Wallplate
• Owners manual
• Screws and anchors
5 69-1199—4
STEP 2. REMOVE OLD THERMOSTAT
!
Test your heating and cooling systems to make sure they work properly. If either system does not work, contact your local heating/air-conditioning dealer. To avoid compressor damage, do not operate the cooling system when outdoor temperature is below 50°F (10°C).
!
Turn off power to the system at the furnace or the fuse/circuit breaker panel.
!
Carefully unpack your new thermostat and wallplate. Save package of screws, instructions, and receipt.
!
Remove the cover from the old thermostat. If the cover does not snap off when pulled firmly from the bottom, check for a screw or screws used to lock on the cover.
!
Loosen the screw or screws holding the thermostat to the wallplate and lift the thermostat away.
!
Disconnect the wires from the old thermostat. As you disconnect each wire, attach the enclosed labels with the old terminal designation. If there are only two wires, they do not need to be labeled. Wrap the wires around a pencil as shown to keep them from falling back into the wall.
Special Installations
Read this section if you are replacing:
• Clock thermostat with separate wires for the clock.
• Thermostat with six or more wires connected to it.
• Thermostat in a heating only system with three wires.
WIRES THROUGH
WALL OPENING
Replacing a Clock Thermostat that has C or C1 Clock Terminals
M5136
If you are replacing a Honeywell Chronotherm® Thermostat, you may find one or two wires going to the C or C1 clock terminals on the Chronotherm wiring wallplate. Do not allow them to touch, or you can damage the transformer. Disconnect the wires and wrap them separately using electrical tape. Do not wrap them together. Place the wires where they will not interfere with the operation of the new thermostat. Record the colors and terminal designation labels of the remaining wires.
Replacing a Thermostat that has Six or More Wires
If there are six or more wires (excluding clock wires attached to terminals), you probably have a variation of a multistage heat pump or other multistage system. This thermostat is not compatible with multistage systems, so return the product to the place of purchase. For information about which programmable thermostats will work with your system, call Honeywell Customer Care at 1-800-468-1502.
69-1199—4 6
Replacing a Thermostat that has Three Wires
If you have three wires for a heating only system and can operate the fan using the fan ON switch this thermostat works with your system. However, some hot water (zoned) heating systems also have three wires. Your thermostat will work only if you install an isolating relay on these systems. For details, call your local heating and/or cooling contractor.
STEP 3. MOUNT THERMOSTAT WALLPLATE
!
Separate the wallplate from the thermostat by placing your thumb or fingers between the bottom of the wallplate and the thermostat, and pulling the wallplate up and away from the thermostat. See illustration at right.
!
Position the wallplate on the wall. Level the wallplate for appearance if desired. Use a pencil to mark the two mounting holes that best fit the application.
M16427
!
Remove the wallplate from the wall. Drill two 3/16 in. holes in wall
(if drywall) as shown. For materials such as plaster or wood, drill
7/32 in. holes where marked. Gently, tap the (provided) anchors into the drilled holes until they are flush with the wall.
!
Reposition the wallplate over the holes. Pull the wires through the wiring opening. Loosely insert mounting screws into each of the holes.
!
Level the wallplate if desired. Thermostat functions properly when not level.
!
Tighten mounting screws.
WALL
ANCHORS (2)
WIRES
THROUGH WALL
WALL
MOUNTING
HOLES
MOUNTING
SCREWS
M15044
7 69-1199—4
STEP 4. WIRE WALLPLATE TERMINALS
IMPORTANT
All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call your local heating/air-conditioning contractor.
Refer to the labels you placed on the wires when you removed the old thermostat (see illustration).
!
Match the letter of your old thermostat wire with the corresponding terminal letter on your new thermostat. Refer to
Table 2.
!
Remove the factory-installed jumper connecting terminals R and
RC if wires are connected to both of those terminals.
!
For wiring diagrams, if needed, see pages 22-23.
!
Loosen the terminal screws. Slip each wire beneath its matching terminal. Wraparound and straight connections are both acceptable, (see illustration). Tighten the terminals.
FOR WRAPAROUND
INSERTION STRIP
7/16 IN. (11 MM).
FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).
G
Y
W
R
M4826
!
Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation.
M16425
69-1199—4 8
Table 2. Terminal Designations on Old and New Thermostats.
Terminal on Old Thermostat
R, RH a , 4, V
Rc, R a
R
Rc
Connect To
Power
Power for cooling
Description
W, W
1
, H
Y, Y
1
, M
G, F
O
B b
C c , X c , B b
W
2
, H
2
Y
2
W
Y
G
O
B b
Do not connect.
Do not continue installation.
Call 1-800-468-1502.
Heat
Cooling
Fan
Changeover in cool. (Single stage heat pump only).
Changeover in heat. (Single stage heat pump only).
Transformer common
Second stage heat.
Second stage cool.
a
If both RH and R terminals are present on existing thermostat, remove jumper and connect Rh to R and R to Rc.
b
Do not connect both O and B when wiring to a single stage heat pump. Connect O to O. Tape off B.
c
Tape off end of the wire with electrical tape and push the taped wire back into the wiring hole in the wall.
STEP 5. INSTALL THE BATTERIES
IMPORTANT
Three fresh AA alkaline batteries must be installed for programming and operation of the thermostat and the heating/cooling system.
!
Install the batteries in the wallplate so the positive terminals all point up (see illustration).
B
WALLPLATE
R RC O W Y G
INSTALL 3 AA ALKALINE BATTERIES
AS SHOWN, POSITIVE (+) TERMINALS
TOWARD TOP.
M10622
9 69-1199—4
!
If the thermostat is already mounted on the wall, remove the thermostat by placing your thumb between the thermostat and wallplate and pulling the thermostat up and away as shown.
When the batteries are running low, a REPL BAT message flashes for one to two months before the batteries run out completely.
Replace the batteries as soon as possible once the message flashes.
IMPORTANT
Although the thermostat has a low battery indicator, replace the batteries once per year to prevent leakage and to prevent the thermostat and heating/cooling system from shutting down due to lack of battery power in the thermostat.
If you insert new batteries within 20 to 30 seconds of removing the old batteries, the system retains the current time and day. If the
M16424 display is blank, the batteries are dead or installed incorrectly. You must reset the time and day. Refer to Set the Clock for instructions.
60
70
80
90
60
70 80
90
As a precaution when leaving home for longer than a month, change batteries before leaving to prevent the system from shutting down due to lack of power. Always use fresh alkaline batteries. Nonalkaline batteries do not last as long. They also can leak, causing damage to the thermostat and the wall surface.
STEP 6. SET FAN OPERATION SWITCH
The thermostat fan operation switch, labeled FUEL SWITCH is factory set in the F position. This is the correct setting for most systems. If your system is an electric heat system, set the switch to E. The E setting allows the fan to turn on immediately with the heating or cooling in a system where the G terminal is connected.
FUEL SWITCH M12676
69-1199—4 10
STEP 7. MOUNT THE THERMOSTAT
A.
ENGAGE TABS AT TOP
OF THERMOSTAT
AND WALLPLATE.
B.
PRESS LOWER
EDGE OF CASE
TO LATCH.
M12703A
STEP 8. CUSTOMIZE YOUR THERMOSTAT
Your Honeywell thermostat comes preset to the most commonly used settings. The settings are:
— Gas or oil forced air furnace.
— Smart Response technology on.
— Temperature °F.
— 12-hour clock format.
You can change any or all of these settings.
IMPORTANT
Always press the keys with your fingertip or a similar blunt tool. Sharp instruments like pens and pencil points can damage the keyboard.
!
Press and hold down , , and , simultaneously until the screen shows.
You now can change any of these settings.
11
FEATURE
NUMBER
OPTION
M13330
69-1199—4
System Type (Feature Number 4)
System type options are:
— 1 = Gravity or steam system.
— 3 = Hot water, high efficiency furnace (90% or better), or single stage heat pump.
— 6 = Gas or oil forced air furnace (preset).
— 9 = Electric furnace.
To change your system type:
!
Press until display shows your furnace or boiler type.
!
Press Time to move to next feature or
Run
Program
to return to main display.
Smart Response™ Technology (Feature Number 13)
Smart Response technology options are:
— 0 = Smart Response technology on (preset).
— 1 = Smart Response technology off.
To turn Smart Response technology on or off:
!
Press
!
Press Time to move to next feature or
Run
Program
to return to main display.
NOTE: See Smart Response technology (page 21) for information about this feature.
Temperature Format (Feature Number 14)
Temperature format options are:
— 0 = °F (preset).
— 1 = °C.
To change temperature format:
!
Press
!
Press Time to move to next feature or
Run
Program
to return to main display.
69-1199—4 12
M13343
M13344
Time Format (Feature Number 16)
Time format options are:
— 0 = 12-hour clock (preset).
— 1 = 24-hour clock.
To change time format:
!
Press
!
Press
Run
Program
to return to main display.
M13345
Factory Set Function (Feature Number 37)
Do not change this setting.
STEP 9. SET THE CLOCK
M13346
Set Current Day and Time
NOTE: On initial power-up, the screen flashes 1:00 pm until you press a key.
!
Press .
!
!
Press Day
Press time
until screen shows current day.
or until screen shows current time. (Tapping the Set Curent
Day/Time
will advance the time in one hour increments).
!
Press .
13 69-1199—4
STEP 10. PROGRAMMING
The keyboard is located behind the thermostat cover. The three most frequently used keys are near the display.
Pressing displays the current temperature settings. Pressing the and keys change the temperature. The thermostat displays day, time, program period, temperature and system settings.
There is an individual key for each of the four program periods:
Wake
—The program period when you want the house at a comfortable temperature when you get up and while you
Leave get ready for work or school. (This is a higher temperature during the heating season and a lower temperature during the cooling season).
—The program period you can set for an energy-saving temperature while you are away at work or school.
(This is a lower temperature during the heating season and a higher temperature during the cooling
Return
Sleep season).
—The program period when you want the house at a comfortable temperature for activities before bedtime.
(This is a higher temperature during the heating season and a lower temperature during the cooling season).
—The program period you can set for an energy-saving temperature while you are sleeping. (This is a lower temperature during the heating season and a higher temperature during the cooling season).
Table 3 can be helpful when planning your schedule for time and temperature settings. The thermostat preprogrammed settings are shown in parentheses ( ).
69-1199—4 14
Table 3. Personal Programming Table.
Period
Wake
Leave
Return
Sleep
Default Setting
Time (6:00AM)
Heat a
(70°F/21°C)
Cool b
(78°F/25.5°C)
Time (8:00AM)
Heat a
(62°F/16.5°C)
Cool b (85°F/29.5°C)
Time (6:00PM)
Heat a
(70°F/21°C)
Cool b (78°F/25.5°C)
Time (10:00PM)
Heat a
(62°F/16.5°C)
Cool b (82°F/28°C)
Weekday (Mon-Fri) Saturday (Sat) a Your heating setpoints cannot be higher than 90°F (32°C) or lower than 40°F (4.5°C).
b Your cooling setpoints cannot be higher than 99°F (35°C) or lower than 45°F (7°C).
Program Weekdays
Start by programming the wake time and temperature for weekdays.
!
Press and release
!
Press Day
Wake .
until (Mon-Fri) displays.
!
Press Time or key until the desired time shows in the display.
NOTE: Program times are in 15 minute intervals. For example, 8:00, 8:15, 8:30.
!
Press or key until the desired wake temperature displays.
15
Sunday (Sun)
69-1199—4
The setpoint temperature range is 40°F to 90°F (5°C to 2°C) for heating and 45°F to 99°F (7°C to 37°C) for cooling.
!
Press
Heat/Cool
Settings
to switch between heating and cooling setpoints.
NOTE: Program times are the same for heating and cooling.
!
Press or until the display shows the desired temperature setpoint.
!
Press Leave , Return or Sleep and repeat these steps for each time period. Your weekday is now programmed.
Program Saturday and Sunday
Repeat each step in Program Weekdays for Saturday and Sunday.
!
Press
Run
Program
when the entire week is programmed.
Clear a Program Period
NOTE: Wake cannot be cleared.
!
Press Leave ,
Return
, or Sleep for the program period you want to clear.
!
Press Day until the desired day displays (Mon-Fri Sat; Sun).
!
Press and hold the Leave , Return , or Sleep for approximately 3 seconds until the time and temperature clear.
!
Repeat the above steps for each period to be cleared.
!
Press .
69-1199—4 16
STEP 11. OPERATING YOUR THERMOSTAT
Change Temperature Setting Until the Next Program Period (Temporary Change)
!
Press or until the screen shows the desired temperature setting.
NOTE: The temporary temperature setting is displayed for about 3 seconds and then the room temperature is displayed. Temporary appears in the display. The setting cancels when the next program period starts or when you press Run
Program
.
Change Temperature Setting Indefinitely (Hold)
!
Move the System switch to the desired position (Heat or Cool).
!
Press
Hold Temp
then or to change your setting if desired. (The display changes from showing the setpoint temperature to room temperature after approximately three seconds).
!
To cancel “Hold” press
Run
Program
.
Change the Temperature Setting Until a Designated Day and Period (Vacation Hold)
!
Press
!
Press or until the display shows the desired temperature setpoint.
!
Press Time until the desired number of days that you will be away (1 through 255) is displayed.
!
Press Wake , Leave , Return or Sleep to select the program period when you want the program to restart.
NOTE: If the Vacation Hold needs to be cancelled before the designated time, press program.
Run
Program
to return to the
17 69-1199—4
STEP 12. SET THE FAN AND SYSTEM SWITCHES
First set the fan switch.
Fan On: The fan runs continuously. Use for improved air circulation or for more efficient central air cleaning. (In a heat-only system, fan runs continuously only if fan relay is connected to the G thermostat terminal).
Fan Auto: Normal setting for most homes. The equipment controls the fan operation.
Then set the system switch.
On
Fan
Auto
Heat: The thermostat controls your heating system.
Off: Both the heating and air conditioning systems are off.
Cool: The thermostat controls your air conditioning system.
Heat
System
Heat
System
Heat
System
On
Fan
Auto
Off Cool
Off Cool
Off Cool
69-1199—4 18
IF YOU HAVE A PROBLEM
Table 4. Solution Guide.
If...
Display does not appear.
Then…
• Make sure the batteries are fresh and installed correctly.
• Make sure the thermostat is mounted and latched on the wallplate.
Mount and latch the thermostat on the wallplate if it is not.
Temperature settings will not change
(example; cannot set the heating higher or the cooling lower).
Heating does not come on.
• Make sure the temperature setpoints are:
—40°F to 90°F (4.5°C to 32°C) for heating.
—45°F to 99°F (7°C to 35°C) for cooling.
• Make sure the heating setpoint is above the room temperature.
• Make sure the circuit breaker is not tripped, and reset it if necessary.
• Make sure the power switch at the equipment is in the On position, and set it to On if it is in the Off position.
• Wait five minutes for the system to respond.
• Set the system switch to Heat.
19 69-1199—4
Table 4. Solution Guide.
If...
Cooling does not come on.
Then…
• Make sure the cooling setpoint is below the room temperature.
• Make sure the circuit breaker is not tripped, and reset it if necessary.
• Make sure the system switch at the air conditioner is in the On position, and set it to On if it is in the Off position.
• Wait five minutes for the system to respond.
• Set the system switch to Cool.
System on indicator ( = heat, = cool) is lit, but no warm or cool air is coming from the registers.
Wait five minutes after seeing the flame or snowflake and check the registers again. If no there is no hot or cool air coming from the registers, refer to Heating does not come on or Cooling does not come on. If all of this has been checked, contact your local heating and cooling contractor.
Display flashes during programming.
Temperature setting limit has been reached. The heating setting range is
40°F to 90°F (4.5°C to 32°C). The cooling setting range is 45°F to 99°F
(7°C to 35°C).
Temperature changes occur at the wrong times.
• Check the program times for the period in question.
• Make sure the AM and PM settings are correct.
• Make sure the current time and day settings are correct.
• Reprogram any incorrect settings.
NOTE: If your thermostat is set for Smart Response™ technology, the start times occur before your programmed comfort period.
Toll-Free Customer Assistance
Please read and follow the provided instructions for this thermostat. For additional information, go to www.honeywell.com/yourhome or call Honeywell Customer Care at 1-800-468-1502.
Before calling, please have the following information available:
• Thermostat model number. (Located on back of thermostat).
• Thermostat date code. (Located below model number).
• Type of heating/cooling system (for example, hot water, warm air, oil, or gas).
• Location and number of wires connected to the thermostat.
69-1199—4 20
SMART RESPONSE™ TECHNOLOGY
Your thermostat is actually a small computer. The Smart Response technology calculates the correct time of day to turn on your heating or cooling system. Smart Response technology considers the following information.
• Air temperature.
• Wall temperature.
• The time of day when you want the comfort temperature established.
When the thermostat activates Smart
Response technology, the thermostat displays In Recovery, changes the setpoint, and turns on the system.
• Your thermostat learns from experience. Each day it checks how closely it hit the recovery target and then adjusts the next days recovery start time accordingly.
• It takes a few days after installation for the thermostat to adjust to the local weather, your lifestyle, the construction of your home, and your heating/cooling system.
• You can turn off Smart Response technology by selecting Conventional
Recovery. See Step 8. Customize
Your Thermostat.
68 F
System Operating in Comfort Mode
AM
Mon
Wake
System
Heat
Room
Recovery
Continues
66 F
64 F
62 F
Mon
System
Heat
AM
Sleep In
Heat
Recovery
Room
Recovery
Begins
Mon
System
Heat
AM
Sleep In
Heat
Recovery
Room
1
System Operating in
Energy Savings Mode
AM
Room
Mon
System
Heat
Sleep
5:00 5:30 6:00 6:30
ENERGY
SAVINGS
PERIOD
RECOVERY FROM ENERGY SAVINGS
TIME
COMFORT
PERIOD
THERMOSTAT USES THE SAME SCHEME TO RETURN TO LOWER COMFORT TEMPERATURE DURING
THE COOLING SEASON.
1 IF In Recovery IS DISPLAYED, PRESS TO SEE THE COMFORT SETPOINT.
M18591
21 69-1199—4
WIRING DIAGRAMS
2-WIRE HEAT-ONLY
(JUMPER INTACT)
THERMOSTAT
B
RC O W Y
R G
4-WIRE HEAT/COOL
(JUMPER INTACT)
THERMOSTAT
B
RC O W Y
R G
HEATING
RELAY OR
VALVE COIL
1 POWER SUPPLY.
PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
1
M10616
3-WIRE HEAT ONLY WITH FAN
(JUMPER INTACT)
THERMOSTAT
B
RC O W Y
R G
HEATING
RELAY OR
VALVE COIL
FAN
RELAY
1 POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
1
M10618
69-1199—4 22
HEATING
RELAY OR
VALVE COIL
COOLING
CONTACTOR
COIL
1 POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
FAN
RELAY 1
M10617
4-WIRE SINGLE-STAGE HEAT PUMP
(JUMPER INTACT)
THERMOSTAT
B
RC O W Y
R
3
G
1
2
COMPRESSOR
CONTACTOR
2
COOL
CHANGEOVER
VALVE
FAN
RELAY
HEAT
CHANGEOVER
VALVE
1
2
3
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
USE EITHER O OR B FOR HEAT PUMP CHANGEOVER.
USING A JUMPER WIRE (NOT SUPPLIED) CONNECT
W TO Y.
M12739
5-WIRE HEAT/COOL
(JUMPER REMOVED)
THERMOSTAT
B
RC O W Y
R G
5-WIRE HEAT/COOL WITH DAMPER
(JUMPER INTACT)
THERMOSTAT
B
RC O W Y
R G
HEATING
RELAY OR
VALVE COIL
1
FAN
RELAY
COOLING
CONTACTOR
COIL
1
1 POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND OVERLOAD
M10619
HEAT
DAMPER
1 POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND
OVERLOAD PROTECTION
AS REQUIRED.
HEAT
RELAY
COMPRESSOR
CONTACTOR
COOL
DAMPER
FAN
RELAY
1
M18738
Notice:
This thermostat is a Class B digital apparatus that complies with Canadian Radio Interference Regulations,
CRC c. 1374.
23 69-1199—4
Limited One-Year Warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywells option) within a reasonable period of time.
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or
(ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address:
Honeywell International Inc. USA
Dock 4 — MN10-3860
1885 Douglas Drive North
Golden Valley, MN 55422-3992
Honeywell Canada:
Honeywell Limited/Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario M1V 4Z9
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.
Honeywells sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL
NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING, DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED,
OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF
ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
If you have any questions concerning this warranty, please write Honeywell Customer Care, 1885 Douglas Drive North,
Golden Valley, MN 55422-3992, or call 1-800-468-1502. In Canada, write Retail Products ON30 Honeywell Limited/Honeywell
Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
Automation and Control Solutions
Honeywell International Inc.
Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North
Golden Valley, MN 55422
35 Dynamic Drive
Scarborough, Ontario
M1V 4Z9
69-1199—4 J.S. Rev. 10-04 www.honeywell.com/yourhome
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Total comfort temperature management with Smart Response™ Technology.
- 5 Step 1. Prepare for Installation
- 6 Step 2. Remove Old Thermostat
- 6 Replacing a Clock Thermostat that has C or C1 Clock Terminals
- 6 Replacing a Thermostat that has Six or More Wires
- 7 Replacing a Thermostat that has Three Wires
- 7 Step 3. Mount Thermostat Wallplate
- 8 Step 4. Wire Wallplate Terminals
- 9 Step 5. Install the Batteries
- 10 Step 6. Set Fan Operation Switch
- 11 Step 7. Mount the Thermostat
- 11 Step 8. Customize Your Thermostat
- 13 Step 9. Set the Clock
- 13 Set Current Day and Time
- 14 Step 10. Programming
- 17 Step 11. Operating Your Thermostat
- 18 Step 12. Set the Fan and System Switches
- 19 If You Have a Problem
- 20 Toll-Free Customer Assistance
- 21 Smart Response™ Technology
- 22 Wiring Diagrams
- 24 Limited One-Year Warranty