Lucent Technologies GRF 1600, GRF 400 Getting Started
Reklama
Reklama
GRF
®
400/1600 Getting Started
1.4. Update 2
Part Number: 7820-2035-001
For software version 1.4.20 and later
September, 1999
Copyright© 1999 Lucent Technologies. All Rights Reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts, or licensing, without the express written consent of Lucent Technologies.
For permission to reproduce or distribute, please contact: Alison Gowan, 1-612-996-6891
Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. However, information is subject to change.
Trademarks
GRF is a trademark of Lucent Technologies. Other trademarks and trade names mentioned in this publication belong to their respective owners.
Limited Warranty
Lucent Technologies provides a limited warranty to this product. See Appendix B, "Limited Warranty," in the GRF 400/1600 Getting Started manual for more information.
Ordering Information
To order copies of this document, contact your Lucent Technologies representative or reseller.
Support Telephone Numbers
For a menu of support and other services, call (800) 272-3634. Or call (510) 769-6001 for an operator.
Lucent Technologies
Customer Service
Customer Service provides a variety of options for obtaining information about Lucent products and services, software upgrades, and technical assistance.
Finding information and software on the Internet
Visit the Web site at http://www.ascend.com
for technical information, product information, and descriptions of available services.
Visit the FTP site at ftp.ascend.com
for software upgrades, release notes, and addenda to this manual.
Obtaining technical assistance
You can obtain technical assistance by telephone, email, fax, modem, or regular mail, as well as over the Internet.
Enabling Lucent to assist you
If you need to contact Lucent for help with a problem, make sure that you have the following information when you call or that you include it in your correspondence:
• Product name and model.
• Software and hardware options.
• Software version.
• Type of computer you are using.
• Description of the problem.
Calling Lucent from within the United States
In the U.S., you can take advantage of Priority Technical Assistance or an Advantage service contract, or you can call to request assistance.
Priority Technical Assistance
If you need to talk to an engineer right away, call (900) 555-2763 to reach the Priority Call queue. The charge of $2.95 per minute does not begin to accrue until you are connected to an engineer. Average wait times are less than three minutes.
Other telephone numbers
For a menu of Lucent’s services, call (800) 272-363). Or call (510) 769-6001 for an operator.
GRF 400/1600 Getting Started - 1.4 Update 2 iii
Calling Lucent from outside the United States
You can contact Lucent by telephone from outside the United States at one of the following numbers:
Telephone outside the United States
Austria/Germany/Switzerland
(510) 769-8027
(+33) 492 96 5672
Benelux (+33) 492 96 5674
France (+33) 492 96 5673
Italy (+33) 492 96 5676
Japan (+81) 3 5325 7397
Middle East/Africa (+33) 492 96 5679
Scandinavia (+33) 492 96 5677
Spain/Portugal (+33) 492 96 5675
UK (+33) 492 96 5671
For the Asia Pacific Region, you can find additional support resources at http://apac.ascend.com
Obtaining assistance through correspondence
Lucent maintains two email addresses for technical support questions. One is for customers in the United States, and the other is for customers in Europe, the Middle East, and Asia. If you prefer to correspond by fax, BBS, or regular mail, please direct your inquiry to Lucent’s U.S. offices. Following are the ways in which you can reach Customer Service:
• Email from within the U.S.—[email protected]
• Email from Europe, the Middle East, or Asia—[email protected]
• Fax—(510) 814-2312
• Customer Support BBS (by modem)—(510) 814-2302
Write to Lucent at the following address:
Attn: Customer Service
Lucent Technologies Inc.
1701 Harbor Bay Parkway
Alameda, CA 94502-3002 iv GRF 400/1600 Getting Started - 1.4 Update 2
Important safety instructions
The following safety instructions apply to the GRF router models GRF-4-AC, GRF-4-DC,
GRF-16-AC, and GRF-16-DC except as noted:
1 Read and follow all warning notices and instructions marked on the product or included in the manual.
2 Do not attempt to service this product yourself, as opening or removing covers and/or components may expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel.
3 The maximum recommended ambient temperature for all GRF router models is 104˚
Fahrenheit (40˚ Celsius). Care should be given to allow sufficient air circulation or space between units when the GRF chassis is installed in a closed or multi-unit rack assembly because the operating ambient temperature of the rack environment might be greater than room ambient.
4 Slots and openings in the GRF cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, maintain a minimum of 4 inches clearance on the top and sides of the GRF 400 router, and a minimum of 6 inches on the top and sides of the GRF 1600 router.
5 Installation of the GRF 400 or 1600 in a rack without sufficient air flow can be unsafe.
6 If a GRF router is installed in a rack, the rack should safely support the combined weight of all equipment it supports.
- A fully loaded, redundant-power GRF 400 weighs 38.5 lbs (17.3 kg).
- A fully loaded, single-power GRF 400 weighs 32.5 lbs (14.6 kg).
- A four card, redundant-power GRF 1600 weighs 147 lbs (66.2 kg).
- A four card, single-power GRF 1600 weighs 127 lbs (57.2 kg).
7 The connections and equipment that supply power to GRF routers should be capable of operating safely with the maximum power requirements of the particular GRF model. In the event of a power overload, the supply circuits and supply wiring should not become hazardous.
8 Models with AC power inputs are intended to be used with a three-wire grounding type plug - a plug which has a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by modifying the plug or using an adapter.
9 Prior to installation, use an outlet tester or a voltmeter to check the AC receptacle for the presence of earth ground. If the receptacle is not properly grounded, the installation must not continue until a qualified electrician has corrected the problem. Similarly, in the case of DC input power, check the DC ground (s).
10 If a three-wire grounding type power source is not available, consult a qualified electrician to determine another method of grounding the equipment.
11 Models with DC power inputs must be connected to an earth ground through the terminal block Earth/Chassis Ground connectors. This is a safety feature. Equipment grounding is vital to ensure safe operation.
GRF 400/1600 Getting Started - 1.4 Update 2 v
12 Install DC-equipped GRF 400 and 1600 routers only in restricted access areas in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical Code,
ANSI/NFPA 70.
13 Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord.
14 Industry-standard cables are provided with this product. Special cables that may be required by the regulatory inspection authority for the installation site are the responsibility of the customer.
15 When installed in the final configuration, the product must comply with the applicable
Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.
vi GRF 400/1600 Getting Started - 1.4 Update 2
Wichtige Sicherheitshinweise
Die folgenden Sicherheitshinweise gelten für die GRF-Oberfräsenmodelle GRF-4AC,
GRF-4-DC, GRF-16-AC und GRF-16-DC, außer wenn anderweitig angegeben:
1 Lesen und befolgen Sie alle am Produkt angebrachten und im Handbuch enthaltenen
Warnhinweise und Anleitungen.
2 Versuchen Sie nicht, dieses Gerät selbst zu warten bzw. die Abdeckung zu öffnen oder
Bauteile zu entfernen. Hochspannungsgefahr. Die Wartung muß durch qualifiziertes
Fachpersonal ausgeführt werden.
3 Die empfohlene maximale Umgebungstemperatur für alle GRF-Oberfräsenmodelle liegt bei 40º C. Sorgen Sie für gute Belüftung bzw. ausreichenden Abstand zwischen einzelnen
Geräten, wenn das GRF-Gehäuse in einem Einzel- oder Mehrfach-Einschubrahmen installiert werden soll, da die Betriebstemperatur in dem Einschubrahmen evtl. höher als die Raumtemperatur sein kann.
4 Schlitze und Öffnungen im GRF-Gehäuse dienen zur Belüftung. Um einen einwandfreien
Betrieb des Produktes zu gewährleisten und um Überhitzung vorzubeugen, jeweils oben und an den Seiten der GRF-400-Oberfräse mindestens 10,16 cm und an der
GRF-1600-Oberfräse mindesten 15,24 cm Freiraum vorsehen.
5 Bei unzureichender Belüftung ist die Installation eines GRF-400 oder 1600 in einem
Einschubrahmen gefährlich.
6 Bei Installation einer GRF-Oberfräse in einem Einschubrahmen, muß dieser das
Gesamtgewicht aller darin installierten Geräte sicher tragen können.
– Ein komplett bestückter Redundanzstrom-GRF-400 wiegt 17,3 kg.
– Ein komplett bestückter Einzelstrom-GRF-400 wiegt 14,9 kg.
– Ein mit vier Karten bestückter Redundanzstrom-GRF-1600 wiegt 66,2 kg.
– Ein mit vier Karten bestückter Einzelstrom-GRF-1600 wiegt 57,2 kg.
7 Die Adapter und Geräte, die die GRF-Oberfräsen mit Strom versorgen, sollten auch bei maximaler Stromanforderung des einzelnen GRF-Modells noch sicher laufen. Im Fall einer Stromüberlastung sollten die Versorgungskreise und kabel keine Gefahrenquelle darstellen.
8 Alle mit Netzeingängen versehenen Geräte müssen mit einem vorschriftsmäßigen Stecker bestückt sein. Der Stecker bietet die notwendige Erdung und darf in keiner Weise modifiziert oder mit einem Adapter verwendet werden.
9 Überprüfen Sie vor der Installation mit Hilfe eines Steckdosentestgerätes oder eines
Voltmeters die Erdung der Netzsteckdose. Sollte die Steckdose nicht ordnungsgemäß geerdet sein, darf mit der Installation erst fortgefahren werden, wenn ein qualifizierter
Elektriker dieses Problem behoben hat. Handelt es sich um einen Gleichstromeingang ist dieser in gleicher Weise auf ordnungsgemäße Erdung zu überprüfen.
10 Ist keine 3polige geerdete Stromquelle vorhanden, beauftragen Sie einen qualifizierten
Elektriker damit, das Gerät auf andere Weise zu erden.
GRF 400/1600 Getting Started - 1.4 Update 2 vii
11 Bei Modellen mit Gleichstromeingängen muß ein Erdungsdraht entweder an der
Klemmleiste oder an einer Gehäuseschraube angeschlossen werden. Hierbei handelt es sich um eine Sicherheitseinrichtung. Die Erdung des Gerätes ist eine wichtige
Voraussetzung für den sicheren Betrieb.
12 Die gleichstromausgerüsteten Oberfräsenmodelle GRF-400- und GRF-1600-Oberfräse dürfen nur in Bereichen mit beschränktem Zugang, unter Berücksichtigung der anwendbaren Bestimmungen für Elektroinstallationen sowie der Standards ANSI/NFPA
70 installiert werden.
13 Keine Gegenstände auf das Netzkabel stellen. Das Kabel so verlegen, daß Personen nicht versehentlich darauf treten können.
14 Standardkabel sind im Lieferumfang des Produkts enthalten. Sonderkabel, die evtl. gemäß den örtlichen Bestimmungen für die Installation erforderlich sind, sind vom Kunden zu stellen.
15 Zur Installation in der endgültigen Konfiguration muß das Produkt den am Installationsort geltenden Sicherheitsstandards und bestimmungen entsprechen. Genauere Informationen erhalten Sie ggf. bei den zuständigen Behörden.
viii GRF 400/1600 Getting Started - 1.4 Update 2
Contents
Contents
Chapter 1
Chapter 2
About This Guide ............................................................................ xix
Getting Acquainted with the GRF 400........................................... 1-1
Getting Acquainted with the GRF 1600......................................... 2-1
GRF 400/1600 Getting Started - 1.4 Update 2 ix
Contents
Chapter 3 x
Rack Mount and Power On Procedures ........................................ 3-1
GRF 400/1600 Getting Started - 1.4 Update 2
Contents
Chapter 4
Powering on the GRF 1600 ............................................................... 3-22
Initial System Set-up....................................................................... 4-1
First-time power on configuration script ................................................. 4-2
Changing the configuration script later ........................................................ 4-3
GRF 400/1600 Getting Started - 1.4 Update 2 xi
Contents
Chapter 5 xii
Option 1: Log and dump to a PCMCIA device .............................................. 4-11
Option 2: Set up a syslog server ................................................... 4-16
Cabling and Verifying Media Cards ............................................... 5-1
GRF 400/1600 Getting Started - 1.4 Update 2
Contents
Verify media card operation using ping .................................................... 5-31
Rebooting from the VT 100 terminal - grms ..................................................... 5-34
GRF 400/1600 Getting Started - 1.4 Update 2 xiii
Contents
Appendix A
GRF Specifications ......................................................................... A-1
GRF 400 chassis specifications ............................................................ A-2
GRF 1600 chassis specifications .......................................................... A-3
Appendix B
Appendix C
GRF 400 Agency Notices ............................................................... C-1
Appendix D
GRF 1600 Agency Notices ............................................................. D-1
xiv GRF 400/1600 Getting Started - 1.4 Update 2
Figures
Expandable area of system memory ............................................................. 1-4
GRF 400 base unit and component (front view) ......................................... 1-5
Media card and control board stack with slots numbered ............................ 1-5
Memory components and options on the control board ............................... 1-7
Front of Astec AC power supply drawer. ................................................... 1-11
Front of Artesyn AC power supply drawer. ............................................... 1-11
Front of -48V power supply drawer. .......................................................... 1-12
Expandable area of system memory ............................................................. 2-5
GRF 1600 base unit and component areas (front view) .............................. 2-6
Rear panel view of GRF 1600 ................................................................. 2-7
Top view of GRF 1600 chassis with slots numbered ................................... 2-8
Memory components and options on the control board ............................. 2-11
Front of GRF 1600 AC power supply drawer and locking tab................... 2-13
Warning label required for redundant supplies .......................................... 2-15
Front panel of GRF 1600 DC power supply............................................... 2-16
Air intake and exhaust areas of the GRF 400 ............................................... 3-3
GRF 400 control board faceplate and LEDs................................................. 3-8
Warning label required for redundant AC supplies .................................... 3-10
Front of -48V power supply drawer. .......................................................... 3-12
Air intake and exhaust areas of the GRF 1600 ........................................... 3-17
Diagram of proper way to move GRF 1600 into rack ................................ 3-18
Figure 3-12 AC power supply with a power cord locking clamp installed.................... 3-25
Figure 3-15 DC supply wires attached to GRF 1600 DC terminal pairs........................ 3-30
Figure 3-16 Warning label required for redundant DC power supply cover ................. 3-31
Point-to-point Ethernet connector on the control board ............................... 4-5
ATM OC-3c single mode media card faceplate ........................................... 5-9
Faceplate of an ATM OC-12c (version 1) single mode media card........... 5-11
Faceplate of an ATM OC-12c (version 2) single mode media card........... 5-11
Single and multi-mode ATM cable ends .................................................... 5-13
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 xv
Figures
FDDI/Q media card faceplate and LEDs.................................................... 5-15
FDDI optic cable connector and keys......................................................... 5-17
Figure 5-11 FDDI media cards used as single and dual attachment nodes .................... 5-18
Figure 5-26 SONET OC-3c single mode media card faceplate ..................................... 5-28
Figure 5-28 SONET OC-3c single mode media card faceplate and LEDs .................... 5-30
xvi October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Tables
Descriptions of GRF 400 control board LEDs ............................................. 3-8
Descriptions of GRF 1600 control board LEDs ......................................... 3-23
ATM OC-3c single mode laser information ............................................... 5-10
ATM OC-12c csingle mode laser information ........................................... 5-13
SONET OC-3c single mode laser information ........................................... 5-29
Table A-1
GRF 400 chassis characteristics................................................................... A-2
DC power requirement per individual components ..................................... A-4
Characteristics of the GRF 400 control board ............................................. A-5
Characteristics of the GRF 1600 control board ........................................... A-5
ATM OC-3c media card specifications ....................................................... A-8
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 xvii
Tables xviii October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
About This Guide
About 1.4 Update 2
The 1.4 GRF manual set is updated to include new features added since software release
1.4.12. This manual describes the full set of features for GRF units running software version
1.4.20 and later. Some features might not be available with earlier versions of the software.
What is in this guide
The GRF 400/1600 Getting Started guide contains these chapters:
• Chapter 1, “Getting Acquainted with the GRF 400,” describes the GRF 400 system components and operating environment.
• Chapter 2, “Getting Acquainted with the GRF 1600,” describes the GRF 1600 system components and operating environment.
• Chapter 3, “Rack Mount and Power On Procedures,” describes the rack mounting procedure for each GRF model, and provides power on procedures for AC and DC power supplies.
• Chapter 4, “Initial System Set-up,” explains the first-time configuration script, the
Command-line Interface (CLI), and system set up for logging, PCMCIA devices, and other system tasks that bring the GRF to an operational state, ready for media card cabling and verification.
• Chapter 5, “Cabling and Verifying Media Cards,” describes the set of available IP media cards, their LED activity, and provides the cable requirements for each card.
• Appendix A, “GRF Specifications,” lists technical specifications for the GRF routers and the IP media cards.
• Appendix B, “Warranty,” contains the product warranty information.
• Appendix C, “GRF 400 Agency Notices,” contains the GRF 400 agency information.
• Appendix D, “GRF 1600 Agency Notices,” contains the GRF 1600 agency information.
The guide also includes an index.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 xix
About This Guide
What you should know
What you should know
Configuring and monitoring the GRF requires that a Network Administrator have experience with and an understanding of UNIX systems, and the ability to navigate in a UNIX environment. Knowledge of UNIX, its tools, utilities, and editors is useful, as is experience with administering and maintaining a UNIX system.
Configuring the GRF requires network experience and familiarity with:
– UNIX systems and commands
– IP protocol and routing operations
– IP internetworking
The Network Administrator must understand how TCP/IP internetworks are assembled; what interconnections represent legal topologies; how networks, hosts, and routers are assigned IP addresses and configured into operation; and how to determine and specify route table
(routing) information about the constructed internetwork(s). Although not required, a high-level understanding of SNMP is useful.
xx October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
About This Guide
Documentation conventions
Documentation conventions
Ascend uses standard documentation conventions, which are as follows:
Convention Meaning
|
Monospace text Represents text that appears on your computer’s screen, or that could appear on your computer’s screen.
Boldface t Represents characters that you enter exactly as shown (unless the characters are also in italics—see Italics, below). If you could enter the characters but are not specifically instructed to, they do not appear in boldface.
Italics
[ ]
Represent variable information. Do not enter the words themselves in the command. Enter the information they represent. In ordinary text, italics are used for titles of publications, for some terms that would otherwise be in quotation marks, and to show emphasis.
Square brackets indicate an optional argument you might add to a command. To include such an argument, type only the information inside the brackets. Do not type the brackets unless they appear in bold type.
Separates command choices that are mutually exclusive.
Key1-Key2
Note:
Represents a combination keystroke. To enter a combination keystroke, press the first key and hold it down while you press one or more other keys. Release all the keys at the same time. (For example, Ctrl-H means hold down the Control key and press the H key.)
Introduces important additional information.
!
Caution:
Warns that a failure to follow the recommended procedure could result in loss of data or damage to equipment.
Warns that a failure to take appropriate safety precautions could result in physical injury.
Warning:
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 xxi
About This Guide
Documentation set
Documentation set
The GRF 1.4 Update 2 documentation set consists of the following manuals:
• GRF 400/1600 Getting Started 1.4 Update 2 (this manual)
• GRF Configuration and Management - 1.4 Update 2
• GRF Reference Guide - 1.4 Update 2
• GRF GateD - 1.4 Update 2
Related publications
Here are some related publications that you may find useful:
• Internetworking with TCP/IP, Volume 1 and 2, by Douglas E. Comer, and David L.
Stevens. Prentice-Hall,
• TCP/IP Illustrated, Volumes 1 and 2, by W. Richard Stevens. Addison-Wesley, 1994.
• Interconnections, Radia Perlman. Addison-Wesley, 1992. Recommended for information about routers and bridging.
• Routing in the Internet, by Christian Huitema. Prentice Hall PTR, 1995. Recommended for information about IP, OSPF, CIDR, IP multicast, and mobile IP.
• TCP/IP Network Administration, by Craig Hunt. O’Reilly & Associates, Inc. 1994.
Recommended for network management information.
• Essential System Administration, Æleen Frisch. O’Reilly & Associates, Inc. 1991.
Recommended for network management information. xxii October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 400
1
This chapter describes the components in a GRF 400 router that you need to be familiar with as you set up and install the equipment.
At the end of this chapter is a one-page preview of the tasks to set up and install the GRF.
Please read through the list, the tasks are described in subsequent chapters.
After you have completed this introduction to the GRF 400, go to chapter 3. It contains information for rack-mounting the GRF 400 and procedures you use to power on AC and DC systems.
Chapter 1 covers these topics:
Note: The GRF 400 has hardware that integrates the router management hardware previously contained in the RMS node with components on the GRF 400 control board. A GRF 400 system currently using an RMS node can be upgraded by replacing its control board (optional) and installing 1.4 software.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 1-1
Getting Acquainted with the GRF 400
What is the GRF 400?
What is the GRF 400?
The GRF 400 is a high-performance IP switch designed for high-volume, large-scale public and private backbone applications. It has these main features:
• Performs Layer-3 switching across 4 gigabits/second aggregate bandwidth
• Supports large suite of routing protocols
• Accommodates 1–4 media cards, available media are ATM OC-3c, ATM OC-12c,
10/100Base-T Ethernet (4- and 8-port), HSSI, HIPPI, SONET OC-3c, and FDDI
• Provides advanced dynamic routing, basic filtering, OSPF multicast, SNMP v1, IPv4
• Accommodates redundant, hot swappable power supplies
• Supports a 400W AC power supply unit
• Supports a -48VDC power supply (negative 48V)
• Manages 150K-entry route tables, batch updating with 20 routes per second
The GRF 400 chassis can be mounted in a standard 19” rack unit or on a table. The chassis weighs between 26 and 40 pounds (11.9–18.2 kg), depending upon the number of media cards and power supplies installed.
Which items are included in your system?
This section helps you confirm the items in your system.
• Each system includes a GRF 400 base unit.
• Base unit components vary depending upon the type/number of media cards and power supplies ordered.
• Software is pre-installed at the factory.
AC power cord
If you ordered the GRF with one (two) AC power supply, make sure the shipping box contains:
• one (two) AC power cords
If your GRF 400 has a redundant AC power supply, you should have two power cords.
AC power cord requirements
Use only the AC power cord included with your product or an equivalent cord:
• North America: UL listed, CSA certified, type SJT or SVT, 3-conductor,
18AWG minimum
• outside of North America: Agency-approved for the country of use, cord type
H05VVF3G1.0, 3-conductor, 1.0mm
2
, rated 250V, 10A, plug type suitable for country of use.
1-2 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 400
Site-supplied components
Site-supplied components
To boot the GRF 400, you must attach a VT100-compatible terminal directly to the control board, and you must supply:
• a standard RS-232 null modem cable and the terminal
Optionally, if you later want to directly connect the GRF to a site LAN, you must supply:
• a cross-over 10Base-T Ethernet cable to connect the LAN to a receptacle on the control board
Components you can add
In addition to media cards, options you can order from Lucent include:
• 400W AC power supplies
• negative 48V DC power supplies
• upgrades to system memory (control board RAM)
The GRF 400 ships with a base of 128MB of RAM. Sites can upgrade to a maximum of
512MB in increments of 128MB, as pairs of 64MB SIMMs.
Memory upgrades may only be obtained from Lucent, do not use other sources.
• ATA disk devices in a PCMCIA slot for system logging and backup
Lucent certifies the following ATA-compliant devices for GRF operation:
– Kingston Datapak 520MB, P/N CT520RM
– Sandisk 175MB Flash, P/N SDP3B
– Sandisk 85MB Flash, P/N SDP3B-85-101
– Aved 85MB Flash, P/N AVEF385MB25ATA501
Lucent offers only the 85 MB Flash directly (GRF-AC-FLASH). Customers may purchase the other devices through an external source.
• PCMCIA modems
– US Robotics/MegaHertz 56K PC Card Modem, model xj5560
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 1-3
Getting Acquainted with the GRF 400
Upgrading system memory
Upgrading system memory
Figure 1-1 shows the area of system memory (control board RAM) that can be expanded to
meet site requirements. Memory upgrades are made in 128MB increments up to 512MB.
Memory size and organization
128MB RAM
32MB
(fixed size) expandable to --> 256MB
RAM
- system software
- config files
- GateD binary
- log files
212MB
84MB
- route tables
- ATMP tunnels
--> 384MB
RAM
340MB
--> 512MB
RAM
468MB
8-12MB
(fixed size)
- kernel runs
- GateD runs
= expandable area of RAM
Figure 1-1. Expandable area of system memory
This chart provides general guidelines for memory required in different routing environments.
Although the figures assume BGP peers with 50K route entries, additional memory may be required for higher average numbers of routes per BGP peer.
If the GRF is to support dynamic routing or ATMP home agents and mobile nodes, upgrade to at least 256MB. In environments where large numbers of routes are advertised, upgrade to
512MB.
Customer profile
Amount of control board memory needed
128MB Static routing:
(in high-performance environment)
Small POP 256MB
Medium POP /
ISP backbone
Large POP /
Exchange point /
Route reflection server
384MB
512MB
Space for dynamic routing,
ATMP tables
Route entries on media card
84MB 150K
Route entries in dynamic routing database
212MB
340MB
468MB
150K
150K
150K
Typical number:
35,800
Typical number:
199,000
Typical number:
362,000
Typical number:
521,000
Typical numbe r of peer sessions
0
3
9
12
1-4 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 400
Overview of the GRF 400 base unit
Overview of the GRF 400 base unit
Figure 1-2 shows the GRF 400 base unit from the front. The rack-mountable chassis is 5.25”
high and 19” wide. When you install the GRF, you must provide six to ten inches of side clearance for ambient air intake and heated air exhaust. All ventilation is to the sides.
Intake fans
Back plane
Media card and
IP switch control board stack
Power supplies
Exhaust vents
GRF 400
Lucent T echnolo gies
(g0002)
Figure 1-2. GRF 400 base unit and component (front view)
Figure 1-3 shows the chassis from the cable panel. Power supplies are on the left. The control
board is on the top of the card stack to the right, the four media cards are in the slots below:
A 0 B 0 A 1 B 1
HSSI 4MB
Figure 1-3. Cable panel view of GRF 400
The GRF 400 has four media card slots, 0–3. Slots are numbered top to bottom as shown in
Figure 1-4, the control board is always 66:
Backplane
66
3
2
1
0
Control board
Media card slot numbers
(in decimal)
Figure 1-4. Media card and control board stack with slots numbered
(g0009)
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 1-5
Getting Acquainted with the GRF 400
Overview of the GRF 400 base unit
Control board
GRF 400 control board hardware runs the router management software (RMS). RMS is the communications and control software for the media cards. Other control board components are the system RAM, internal flash memory, switch hardware, Ethernet connector, and PCMCIA device slots. The control board is field-replaceable, but not hot swappable.
•
•
•
•
•
•
•
•
•
PCMCIA
B A
RESET
POWER
FAULT
STATUS
ACTIVE
TRANSMIT
RECEIVE
PS1-OK
PS2-OK
100/10
LINK OK
100
XMT ACT
RCV ACT
RS232
COM1
A hardware reset button, receptacles for Ethernet and RS-232 connections, and power, status and fault LEDs are on the control board’s faceplate, shown left.
PCMCIA slots can contain an external flash memory device and a
PCMCIA modem attachment.
The system can be reset by depressing the reset button, but a software command reset is preferable since it saves files and leaves the system in order.
LEDs provide status for control board and chassis components.
The faceplate speaker functions as a typical PC speaker, it chimes during system boot, for example. The control board has another component that sounds an audible alarm when the operating temperature level is exceeded.
The control board has temperature monitoring (sensor) and reporting (alarm) capabilities. The router management software provides a command (temp) to check the current board-surface operating temperature. If excessive temperature levels are reached, the router management software triggers the control board’s audible alarm. If levels are exceeded, the management software will shut the system down. The management software also monitors the power supply units, issuing power failure warnings to the user interface via grconslog if power problems are detected. The LEDs do not reflect the actual location of power supplies in the chassis: power supply 2 is on top, power supply 1 is on the bottom.
A 10/100 megabit Ethernet receptacle (autosensing) supports a connection to the administrative LAN. A set of four LEDs indicate status (Link OK), activity (XMT ACT, RCV ACT), and connection rate (if 100 Mbs).
TheVT-100 terminal attaches to the serial port.
Switch control
Each media card is on a switch port. Switch control manages media card requests to connect through the switch to the switch port occupied by a destination media card. Switch logic determines if the target port is available and, if it is, enables the connection. A special bus carries the request and grant traffic for available switch ports.
1-6 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 400
Overview of the GRF 400 base unit
System memory
Figure 1-5 illustrates the RAM and flash memory components on the GRF control board:
System RAM 128MB
96
MB
Permanently reserved for file system
32
MB
+
---> 256 MB
64
MB
64
MB +
---> 384 MB
64
MB
64
MB +
---> 512 MB
64
MB
64
MB
Internal flash device
85MB
Slot A Slot B
Control board
CPU
Administrative
LAN ( de0 )
Disk modem
PCMCIA device options
(g0001)
Figure 1-5. Memory components and options on the control board
RAM The GRF 400 is equipped with a minimum of 128MB of internal RAM, 32MB of which are permanently reserved for the file system, including logs and configuration files. The remaining 96MB are used by the operating system and user applications such as GateD.
System memory can be upgraded in 128MB increments up to a total of 512MB, including the
32MB always reserved for the file system. To permit the software to operate in the allocated memory, certain portions of standard UNIX, such as man page files, are omitted. Man pages for GRF commands are maintained.
Because file system space is limited, you should configure logging to be done remotely via
syslog or locally to external flash. Additional system memory supports route tables and other protocol data, and cannot be used for storing logs.
Internal flash The GRF has an internal 85MB ATA flash device from which the system boots. This memory is available for storing different versions of operating software and site configurations.
External flash PCMCIA slots on the control board support various sizes of ATA flash devices. Although external flash can be used to back up and share router configurations among multiple GRF systems, a GRF cannot boot from an external flash device. Local logging and dumping to external flash is also supported. The grwrite command writes files from system
RAM to internal flash, grsnapshot copies files between internal and external flash devices.
Commands for flash device management are discussed in the GRF Configuration and
management manual.
PCMCIA devices PCMCIA slot A is used for a portable external flash device. A PCMCIA modem device can operate in either slot A or B. Instructions for configuring the modem and a disk device are in chapter 4.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 1-7
Getting Acquainted with the GRF 400
Overview of the GRF 400 base unit
Fans
Three intake fans push air across the media cards, control board, and power supplies. Warmed air exhausts out the side vents next to the power supplies. If the unit is installed in a rack, the sides of the GRF chassis should not be adjacent to a device in the next rack. Be sure that the intake vents do not draw in air exhausted by another device. Fans are not swappable. They are part of the GRF 400 chassis and must be replaced by certified personnel.
Fan “too slow” message
You may occasionally see a message in the /messages log file similar to this:
Jul 20 04:00:25 tn-btvt-1-E0-1 kernel: rmb0: RMB Fan 0 is too slow
This message can be generated when the low-priority task of updating the fan rotation count has been replaced by a higher-priority communication bus activity. Unless you see it repeated frequently in a five-minute period, you can ignore it. If the message is repeated, use the grrmb
temp command to check the chassis temperature.
Backplane
The GRF 400 backplane spans the width of the chassis and is fixed in place. The backplane is not a field replaceable unit.
The backplane supplies power to the media cards and control board. The control board and media cards exchange configuration and status information through the 80 megabit/second communications bus located on the backplane.
Communications bus
The communications bus (com bus) is a separate data path for configuration, control, monitoring functions. This bus connects the control board to the media cards independently of the switch connection to each card, and is not used for routed data between media cards. Route table update packets received by the media cards are also sent across the com bus to the router manager software and do not compete with normal IP data traffic.
Battery
The control board has a small 3V lithium battery to store BIOS CMOS configuration and for powering the real time clock if the GRF is powered off.
!
Caution: Danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
Vorsicht : Explosionsgefahr bei unsachgemäßem Austausch der Batterie. Ersatz nur durch denselben oder einen vom Hersteller empfohlenen gleichwertigen Typ. Entsorgung gebrauchter Batterien nach Angaben des Herstellers.
Attention: Il y a danger d’explosion s’il y a remplacement incorrect de la batterie.
Remplacer uniquement avec une batterie du même type ou d’un type équivalent recommandé
1-8 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 400
Overview of the GRF 400 base unit par le constructeur. Mettre au rebut les batteries usagées conformément aux instructions du fabricant.
Power supplies
The GRF 400 can use either AC or DC (negative 48VDC) power supplies. GRF systems are shipped with the power supply installed. Power supplies are housed in open frame drawers for cooling by the chassis fans. Only qualified personnel can service and replace GRF 400 power supplies.
Remember that the GRF 400 does not have a power on/off switch. When the power supplies receive current, the GRF powers on and, since the software is already loaded, immediately begins to boot.
Redundant units
Two power supplies can be installed for redundancy. When two units are present, both are active, load-sharing devices. If one fails, the other unit ramps up to provide the full load. Each power supply has an LED on the control board.
Looking from the cabling end of the chassis, the power supplies are mounted on the left side.
The bottom power supply is numbered 1, and the upper supply is numbered 2. In a non-redundant system, the single power supply unit can be installed in either 1 or 2, it does not matter.
If a unit failure occurs in a redundant system, the failed unit can be hot swapped out. The unit being removed must be unplugged or disconnected from its AC or DC power source.
Failure notification
If a power supply fails, you will see failure messages on-screen at the user interface. The
/var/log/gr.console
log file will also contain related messages. The green PS1-OK or
PS2-OK LED on the control board goes off to indicate a power supply failure. If you do not already have a replacement unit, order one from Lucent.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 1-9
Getting Acquainted with the GRF 400
Description of the AC power supply
Description of the AC power supply
The GRF 400 400W AC power supply provides +5V to all media cards, control board, and backplane. Remember that the GRF 400 chassis does not have a power on/off switch. When you plug the AC power supply cord into a live outlet, the GRF powers on and, since the software is already loaded, immediately begins to boot.
The GRF 400 can be ordered with one or a redundant pair of AC power supply units. The AC unit is available only from Lucent.
Powering on a GRF 400 power supply is described in Chapter 3.
A note about redundant AC supplies
When the GRF 400 is equipped with redundant AC power supplies, please note the following when powering on (plugging) or powering off (unplugging) the GRF unit:
Caution: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords. Care must be taken to correctly connect each power supply to separate AC power sources and (optional) UPS devices.
Vorsicht : Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollständig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
Achten Sie darauf, daß jedes Stromkabel mit einer separaten Wechselstromquelle und einem separaten USV-Gerät verbunden wird.
Attention : Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
Incompatibilities between AC power supply models
For some time the GRF 400 has been equipped with 400W power supplies manufactured by
Astec.
The standard AC power supply is being switched to a unit manufactured by Artesyn
(previously Zytec). Refer to Figure 1-6 and Figure 1-7 for front panel illustrations of both
types of power supplies.
The Astec and Artesyn power supplies are incompatible. The two models do not consistently support load sharing between them, and their incompatibilities can mask a unit failure. As a result, the two models must not be installed together in the same GRF 400 chassis.
This installation requirement is critical in the following situations:
• when a system with a single Astec unit intends to install a second unit for redundancy.
If you intend to add a redundant unit to a GRF 400 with a single Astec unit installed (black handle), you must switch to two Artesyn units.
• when a system with dual Astec units has a failure and needs a replacement unit.
If you have a failure in a GRF 400 configured with dual Astec units, you must switch to two Artesyn units.
1-10 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 400
Description of the AC power supply
• units might be swapped at sites having multiple GRF 400 units with different power supplies.
If you swap power supplies, remember you cannot mix models in the same GRF chassis.
Contact your Lucent sales representative to order the appropriate power supply units.
Astec supplies have a black pull handle as shown in Figure 1-6:
Black handle
(This label is present only when
a second supply is installed.)
!
CAUTION: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords.
ACHTUNG: Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollständig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
Figure 1-6. Front of Astec AC power supply drawer.
The Artesyn power supply has a silver pull handle as shown in Figure 1-7:
Silver handle
CAUTION: This unit has two power supply cords.
For total isolation from electrical shock and energy hazard, disconnect both supply cords.
100-240V
ACHTUNG: Dieses Gerät hat zwei
Netzanschlusskabel. Um das Gerät vollständig von Netz zu trennen ziehen
Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
ATTENTION: Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc
électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
(This label is present only when
a second supply is installed.)
Figure 1-7. Front of Artesyn AC power supply drawer.
Note:
When replacing Astec units in a redundant system with Artesyn (previously Zytec) supplies, the units can be hot swapped, there is no need to power off the GRF unit. Do not leave one of each type of supply (one Artesyn and one Astec unit) "mixed" in the GRF 400 for an extended period of time. To keep the GRF 400 up and running, mixing power supplies during a brief hot swap is acceptable.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 1-11
Getting Acquainted with the GRF 400
Description of the 48V DC power supply
Description of the 48V DC power supply
The GRF 400 can be ordered with one or a redundant pair of negative 48V DC power supply units. The DC unit is available only from Lucent.
Attaching DC supply wiring to the DC power supplies is described in Chapter 3.
The terminals and markings of a GRF 400 DC power supply are shown in Figure 1-8:
Cover area
!
Figure 1-8. Front of -48V power supply drawer.
Redundant DC supply safety considerations
The notice shown below appears on the lower edge of the GRF 400 DC power supply:
!
SEE INSTRUCTION MANUAL and refers to the following caution:
If the GRF is equipped with redundant DC power supplies, please note the following when powering off (disconnecting) the GRF unit:
Caution: This unit has two power inputs. For total isolation from electrical shock and energy hazard, disconnect both power inputs. Care must be taken to correctly connect each power supply to separate power sources and (optional) UPS devices.
Vorsicht : Dieses Gerät hat zwei Stromeingänge. Um das Gerät vollständig vom Netz zu trennen, unterbrechen Sie den Anschluß mit beiden Eingängen, sonst können Sie einen elektrischen Schlag erhalten. Achten Sie darauf, daß jedes Stromkabel mit einer separaten
Wechselstromquelle und einem separaten USV-Gerät verbunden wird.
Attention : Cet appareil a deux sources d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux sources d’alimentation.
1-12 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 400
Installation preview
Installation preview
Now that you are familiar with the GRF 400, this page gives you a preview of the tasks you will do to install the GRF, and what the other chapters in this Getting Started manual cover:
1 Rack mount and ground the GRF chassis. (chapter 3)
2 Insert any additional media cards. The GRF is shipped with all ordered media cards installed, if you have others to install, insert them now. (chapter 3)
3 Attach a VT 100-compatible terminal or laptop PC to the serial port (RS-232) on the GRF control board. The terminal is used to enter the initial IP configuration information and to monitor system boot. Later you can connect the GRF to the administrative Ethernet and disconnect the terminal. (chapter 3)
4 Power on the GRF by plugging in the AC power supply or wiring the DC power supply.
The GRF has no on/off switch, and ships with software already loaded. When you apply current to the power supplies, the GRF begins to boot. Watch the control board LEDs to see the status of the system during and after boot. (chapter 3)
5 The first time a GRF is powered on, a configuration script automatically runs. The script prompts you to enter the router’s system IP address and host name. You must supply this information to communicate with the GRF and to later connect the GRF to your administrative Ethernet. (chapter 4)
The script also prompts you to begin to configure remote logging by setting up a syslog server. If you choose to configure “local” logging to a PCMCIA device, just press the
<Enter> key at those prompts.
6 Log in as root . Optionally, you can change the preset password for root . (chapter 4)
7 Configure logging, there are several options. Procedures to set up local PCMCIA and network logging are in this manual. (chapter 4)
Optionally, you can install and configure a PCMCIA modem connection to the GRF.
8 Connect the GRF maintenance Ethernet interface to your site’s administrative LAN. Use the Ethernet connector on the control board. If you like, you can now disconnect the VT
100 terminal. (chapter 4)
9 Attach the media card cables. (chapter 5)
At the end of this Getting Started manual, you are ready to configure the media card interfaces, network services, and protocols. This information is covered in the GRF Configuration and
Management manual.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 1-13
Getting Acquainted with the GRF 400
Installation preview
1-14 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 1600
2
This chapter describes the components in a GRF 1600 router that you need to be familiar with as you set up and install the equipment.
At the end of this chapter is a one-page preview of the tasks to set up and install the GRF.
Please read through the list, the tasks are described in subsequent chapters.
After you have completed this introduction to the GRF 1600, go to chapter 3. It contains information for rack-mounting the GRF 1600 and procedures you use to power on AC and DC systems.
Chapter 2 covers these topics:
Note: The GRF 1600 replaces the GR-II (GigaRouter) and its attached RMS node as a high-performance router product.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 2-1
Getting Acquainted with the GRF 1600
What is the GRF 1600?
What is the GRF 1600?
The GRF 1600 is a high-performance IP switch designed for high-volume, large-scale public and private backbone applications. It has these main features:
• Performs Layer-3 switching across 16 gigabits/second aggregate bandwidth
• Supports large suite of routing protocols
• Accommodates 1–16 media cards, available media are ATM OC-3c, ATM OC-12c,
10/100Base-T Ethernet (4- and 8-port), HSSI, HIPPI, SONET OC-3c, and FDDI
• Provides advanced dynamic routing, basic packet filtering, OSPF multicast, SNMP v1,
IPv4
• Accommodates redundant, hot swappable power supplies
• Supports an 1100W AC power supply unit
• Supports a -48VDC power supply (negative 48V)
• Manages 150K-entry route table, batch updating with 20 routes per second
The GRF 1600 chassis can be mounted in a standard 19” rack unit or on a table.
The chassis weighs between 107 and 124 pounds (49–56 kg), depending upon the number of power supplies installed. Side rails are recommended to be installed in the rack unit before attempting to insert a GRF 1600. Side rails will help to support the heavy unit as the team inserts the chassis and fastens it to the rack.
!
Caution: Because of its weight, moving the GRF 1600 into a rack requires a two-person team.
Vorsicht : Aufgrund seines Gewichts sind zur Installation des GRF 1600 auf dem Regal zwei
Personen erforderlich.
2-2 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 1600
Which items are included in your system?
Which items are included in your system?
This section helps you confirm the items in your system.
• Each system includes a GRF 1600 base unit.
• Unit contents vary depending upon the type/number of media cards ordered.
• Software is pre-installed at the factory.
AC power cord
For AC systems, make sure the shipping box contains an AC power cord. If your GRF 1600 has a redundant AC power supply, you should have two power cords.
• one (two) AC power cords
AC power cord requirements
Use only the power cord included with your product or an equivalent cord:
• North America:
UL listed, CSA certified, type SJT or SVT, 3-conductor, 18AWG minimum
• outside of North America:
Agency-approved for the country of use, cord type H05VVF3G1.5, 3-conductor,
1.5mm
2
, rated 250V, 16A; plug type suitable for country of use
Site-supplied components
To boot the GRF 1600, you must attach a VT100-compatible terminal directly to the serial receptacle on the control board, and you must supply:
• a standard RS-232 null modem cable
• a VT100-compatible terminal
Optionally, if you later want to directly connect the GRF to a site LAN, you must supply:
• a cross-over 10Base-T Ethernet cable to connect the LAN to the Ethernet receptacle on the control board
Components you can add
In addition to media cards, GRF 1600 options you can order from Lucent include:
• 1100W AC power supplies
• a locking clamp for the AC power supply is available from Panel Components
Corporation, P/N 85910051, (515) 673-5000
• negative 48V DC power supplies
• upgrades to internal control board RAM
The GRF 1600 ships with a base of 128MB of RAM. Sites can upgrade to a maximum of
512MB in increments of 128MB, as pairs of 64MB SIMMs.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 2-3
Getting Acquainted with the GRF 1600
Components you can add
Memory upgrades may be obtained only from Lucent, do not use other sources.
• ATA disk devices in a PCMCIA slot for system logging and backup
Lucent certifies the following ATA-compliant devices for GRF operation:
– Kingston Datapak 520MB, P/N CT520RM
– Sandisk 175MB Flash, P/N SDP3B
– Sandisk 85MB Flash, P/N SDP3B-85-101
– Aved 85MB Flash, P/N AVEF385MB25ATA501
Lucent offers only the 85 MB Flash directly (GRF-AC-FLASH). Customers may purchase the other devices through an external source.
• Lucent certifies the following PCMCIA modem for use in a GRF 1600:
– US Robotics/MegaHertz 56K PC Card Modem, model xj5560
2-4 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 1600
Upgrading system memory
Upgrading system memory
Figure 2-1 shows the area of system memory (control board RAM) that can be expanded to
meet site requirements. Memory upgrades are made in 128MB increments up to 512MB.
Memory size and organization
128MB RAM
32MB
(fixed size) expandable to --> 256MB
RAM
- system software
- config files
- GateD binary
- log files
212MB
84MB
- route tables
- ATMP tunnels
--> 384MB
RAM
340MB
--> 512MB
RAM
468MB
8-12MB
(fixed size)
- kernel runs
- GateD runs
= expandable area of RAM
Figure 2-1. Expandable area of system memory
This chart provides general guidelines for memory required in different routing environments.
Although the figures assume BGP peers with 50K route entries, additional memory may be required for higher average numbers of routes per BGP peer.
If the GRF is to support dynamic routing or ATMP home agents and mobile nodes, upgrade to at least 256MB. In environments where large numbers of routes are advertised, upgrade to
512MB.
Customer profile
Amount of control board memory needed
128MB Static routing:
(in high-performance environment)
Small POP 256MB
Medium POP /
ISP backbone
Large POP /
Exchange point /
Route reflection server
384MB
512MB
Space for dynamic routing,
ATMP tables
Route entries on media card
84MB 150K
Route entries in dynamic routing database
212MB
340MB
468MB
150K
150K
150K
Typical number:
35,800
Typical number:
199,000
Typical number:
362,000
Typical number:
521,000
Typical numbe r of peer sessions
0
3
9
12
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 2-5
Getting Acquainted with the GRF 1600
Overview of the GRF 1600 base unit
Overview of the GRF 1600 base unit
Figure 2-2 shows the GRF 1600 base unit from the front of the cabinet. All cables and power
cords attach at the rear panel. The GRF 1600 chassis is organized into three sections.
In the top section, a pair of high-speed impeller fans draw air up through the media cards and exhaust it out vents on each side of the chassis. These vents must not be obstructed in any way.
When you install the GRF, you must provide a minimum of 6 inches of clearance on the sides of the unit and keep the front and back clear of obstruction. The backplane and system cards are installed in the middle section, above the air intake plenum. Intake vents are at each chassis side and front. Power supplies are in the bottom section. Their internal fans exhaust air out the lower chassis front and require a minimum of six inches of clearance.
Note the hand holds on the chassis sides, these are especially helpful when installing the GRF in a rack.
Impeller fans
Fan exhaust vent
GRF 1600
Lucent T echnolo gies
Media cards, control board, switch board
Backplane
Power supply intake air
Hand hold
Power supplies
Power supply fan exhaust vent
(g0143)
Figure 2-2. GRF 1600 base unit and component areas (front view)
2-6 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 1600
Overview of the GRF 1600 base unit
The rear panel of the GRF 1600 chassis is shown in Figure 2-3. At the top is a fan tray that
houses a pair of motorized impeller fans, the tray is field-replaceable as a single unit.
The top and bottom of the media card section are open grids through which the fans draw air through the chassis air intake vents. The media cards slide in along the guide in each slot and plug into their connector on the backplane. Solid vertical partitions separate the control board and the switch board from the media cards.
S
O
U
R
C
E
I
N
A
T
D
E
S
T
I
O
N
HIPPI
PWR
STAT
DST
SRC
DST
SRC
RX
TX
FDDI
S
T
A
T
PWR
0 1
A
0
TRX
B
0
A
ATM
3c
PWR
FAULT
STAT 0
STAT1
RCV
XMT
LINK
ATM
12c
ATM
OC-12C
SM
PWR
FAULT
STAT 0
STAT1
RCV
XMT
LINK
LASER
A
1
TRX
B
1
B
ATM
OC-3c
SM
ATM
OC-12c
SM/IR
CLASS 1\
LASER
PRODUCT
KLASSE 1
LASER
PRODUKT
CONTROL
BOARD
B A
SWITCH
BOARD
• •
• •
• •
• •
• •
PWR
STATUS
PCMCIA
ACT
RCV
FAN
PS1
XMT
TEMP
PS2
•
RESET
•
•
•
•
• ••••
•
•
•
•
•
•
LINK OK
100
XMT ACT
RCV ACT
••
••
•
••
••
RS232
COM1
Ethernet
8-port
7
6
5
4
3
2
1
0
Ethernet
4-port
SONET
3c
1
0
3
2
B
RCV
XMT
LINK
A
PWR
FAULT
STAT 0
STAT1
RCV
XMT
LINK
HSSI
PWR
FAULT
STAT 0
STAT1
STAT2
A
B
Cable harness
Fan tray
Control board
PCMCIA slots A, B
Switch board
Reset button
Speaker
Ethernet LAN
Vertical bulkhead
Chassis air intake vent
Wrist strap ground
Locking tab
Sliding plate finger lift
AC receptacle
Power supply 2 drawer (PS2)
Power supply fan intake
Rack ground
Power supply 1 drawer (PS1)
Figure 2-3. Rear panel view of GRF 1600
Two ground connectors are on the right edge of the chassis, the upper is for a wrist strap and the lower is for the rack ground.
The power supply compartment is completely separate from the rest of the chassis. Each power supply is in an enclosed drawer and is cooled by an internal fan. A locking tab prevents the drawer from being opened accidentally when the AC cord is plugged into the unit. The PS1 or
PS2 LED on the control board lights to indicate a problem with a specific power supply.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 2-7
Getting Acquainted with the GRF 1600
Overview of the GRF 1600 base unit
Media cards
Note: To operate properly, a GRF 1600 requires a minimum of two media cards installed.
Also, a face plate cover must be installed in any unused slot to maintain cooling flows.
The GRF 1600 has 16 media card slots, 0–15, a control board, and a switch board.Slots are
numbered left to right as shown in Figure 2-4, the control board is always 66:
Backplane
Media cards:
Slot numbers: 0 1 2 3 4 5 6 7
Control board
66 8 9 10 11 12 13 14 15
Switch board
Figure 2-4. Top view of GRF 1600 chassis with slots numbered
Chassis fans
Two motorized impeller fans cool the chassis, excluding the power supply compartment. The fans operate in tandem. At start-up, both fans operate at 100% of RPM capability. Gradually each fan slows down so that, in normal conditions, each fan operates at 50% speed. When the
GRF is plugged in, you can hear the changes in fan speeds. Tachometers on each fan unit ensure steady, sufficient airflow. When a tachometer detects that a fan is dropping below the
50% rate, it causes a signal to the other fan to speed up. When a problem occurs with either fan, the control board “FAN” LED lights. You can replace the fan tray on site, contact Lucent to order a replacement.
The amount of time the GRF 1600 can operate with a failed fan depends upon the number of installed media cards and the ambient air temperature. The temperature sensor on the control board shuts the GRF down if the operating temperature is exceeded.
A procedure to exchange the fan trays is in the “Management Tasks” chapter of the GRF
Configuration and Management manual.
2-8 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 1600
Overview of the GRF 1600 base unit
Control board
GRF 1600 control board hardware runs the router management software (RMS). RMS is the communications and control software for the media cards.
Other control board components are the system RAM, internal flash memory, maintenance
Ethernet connector, and PCMCIA device slots. The control board is field-replaceable, but not hot swappable.
PCMCIA
B A
• •
• •
• •
• •
• •
PWR PCMCIA
STATUS ACT
RCV
FAN
PS1
XMT
TEMP
PS2
RESET
•
•
•
•
•
•
•
•
•
100/10
LINK OK
100
XMT ACT
RCV ACT
RS232
COM1
A hardware reset button, receptacles for maintenance Ethernet and RS-232 connections, and power, fan, status and fault LEDs are on the board’s faceplate, shown left.
PCMCIA slots can contain an external flash memory device and a
PCMCIA modem attachment.
LEDs provide status for control board and chassis components.
The system can be reset by depressing the reset button, but a software command reset is preferable since it saves files and leaves the system in order.
The faceplate speaker functions as a typical PC speaker, it chimes during system boot, for example. The control board has another component that sounds an audible alarm when the operating temperature level is exceeded.
The control board has temperature monitoring (sensor) and reporting (alarm) capabilities. The router management software provides a command (temp) to check the current board-surface operating temperature. If excessive temperature levels are reached, the router management software triggers the control board’s audible alarm. If levels are exceeded, the management software will shut the system down. The management software also monitors the power supply units, issuing power failure warnings to the user interface via grconslog if power problems are detected.
A 10/100 megabit Ethernet receptacle (autosensing) supports a connection to the administrative LAN. A set of four LEDs indicate status (Link OK), activity (XMT ACT, RCV ACT), and connection rate (if 100 Mbs).
TheVT-100 terminal attaches to the serial port.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 2-9
Getting Acquainted with the GRF 1600
Overview of the GRF 1600 base unit
Switch board
The 16x16 switch chip and switch control logic reside on the GRF 1600 switch board. The switch board is field-replaceable, but not hot swappable. It is installed to the right of the control board in the central chamber.
Switch control
Each media card is on a switch port. Switch control manages media card requests to connect through the switch to the switch port occupied by a destination media card. Switch logic determines if the target port is available and, if it is, enables the connection. A special bus carries the request and grant traffic for available switch ports.
Battery
The control board has a small 3V lithium battery to store BIOS CMOS configuration and for powering the real time clock if the GRF is powered off.
!
Caution: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
Vorsicht : Explosionsgefahr bei unsachgemäßem Austausch der Batterie. Ersatz nur durch denselben oder einen vom Hersteller empfohlenen gleichwertigen Typ. Entsorgung gebrauchter Batterien nach Angaben des Herstellers.
Attention: Il y a danger d’explosion s’il y a remplacement incorrect de la batterie.
Remplacer uniquement avec une batterie du même type ou d’un type équivalent recommandé par le constructeur. Mettre au rebut les batteries usagées conformément aux instructions du fabricant.
Backplane
The GRF 1600 backplane spans the width of the chassis and is fixed in place. The backplane is not a field replaceable unit.
The backplane supplies power to the media cards and control board. The control board and media cards exchange configuration and status information through the 80 megabit/second communications bus located on the backplane.
Communications bus
The communications bus (com bus) is a separate data path for configuration, control, monitoring functions. This bus connects the control board to the media cards independently of the switch connection to each card, and is not used for routed data between media cards. Route table update packets received by the media cards are also sent across the com bus to the router manager software and do not compete with normal IP data traffic.
2-10 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 1600
Overview of the GRF 1600 base unit
System memory
Figure 2-5 illustrates the RAM and flash memory components on the GRF control board:
System RAM 128MB
96
MB
Permanently reserved for file system
32
MB
+
---> 256 MB
64
MB
64
MB +
---> 384 MB
64
MB
64
MB +
---> 512 MB
64
MB
64
MB
Control board
CPU
Administrative
LAN ( de0 )
Internal flash device
85MB
Slot A Slot B modem
PCMCIA device options
Disk
(g0001)
Figure 2-5. Memory components and options on the control board
RAM The GRF 1600 is equipped with a minimum of 128MB internal RAM, 32MB of which are permanently reserved for the file system, including logs and configuration files. The remaining 96MB are used by the operating system and user applications such as GateD.
System memory can be upgraded in 128MB increments up to a total of 512MB, including the
32MB always reserved for the file system. To permit the software to operate in the allocated memory, certain portions of standard UNIX, such as man page files, are omitted. Man pages for GRF commands are maintained.
Because file system space is limited, you should configure logging to be done remotely via
syslog or locally to external flash. Adding system memory only supports route tables and other protocol data, additional memory cannot be used for storing logs. Chapter 4 describes options for configuring external logging.
Internal flash The GRF has an internal 85MB ATA flash device from which the system boots. This memory is available for storing different versions of operating software and site configurations.
External flash PCMCIA slots on the control board support various sizes of ATA flash devices. Although external flash can be used to back up and share router configurations among multiple GRF systems, a GRF cannot boot from an external flash device. Local logging and dumping to external flash is also supported. The grwrite command writes files from system
RAM to internal flash, grsnapshot copies files between internal and external flash devices.
Commands for flash device management are discussed in the GRF Configuration and
management manual.
PCMCIA devices PCMCIA slot A is used for a portable external flash device. PCMCIA modem devices can operate in either slot A or B. Instructions for installing and configuring the modem and a disk device are in chapter 4.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 2-11
Getting Acquainted with the GRF 1600
Overview of the GRF 1600 base unit
Power supply options
The GRF 1600 uses either AC or DC (negative 48VDC) power supplies. GRF systems are shipped with the power supply installed. Power supplies are housed at the bottom of the chassis in self-contained, self-cooled drawers. Visible from the cabling end of the chassis, power supply 1 (PS1 LED) is on the left, power supply 2 (PS2 LED) is on the right. In a non-redundant system, the single power supply unit can be installed in either 1 or 2, it does not matter. Only qualified personnel can service and replace GRF 1600 power supplies.
Two power supplies can be installed for redundancy. When two units are present, both are active, load-sharing devices. If one fails, the other unit ramps up to provide the full load. Each power supply has an LED (PS1, PS2) on the control board. If a unit failure occurs in a redundant system, the failed unit can be hot swapped out. The unit being removed must be unplugged or disconnected from its AC or DC power source.
Each power supply has an internal fan to cool that unit. Air is drawn in at the drawer front and exhausted out the rear of the drawer. If a power supply overheats, its internal regulators will shut the unit down.
Power supply failure notification
If a power supply fails, you will see failure messages on-screen at the user interface. The gr.console
log file will also contain related messages. The amber PS1 or PS2 LED on the
GRF 1600 control board will come on to indicate a power supply failure. If you do not already have a replacement unit, order one from Lucent.
Warning: A failed power supply must be replaced by certified personnel only.
Warnung: Das Netzteil darf nur von einer Fachkraft ausgewechselt werden.
2-12 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 1600
Description of the AC power supplies
Description of the AC power supplies
The GRF 1600 1100W AC power supply provides +48V to the fans and +5.0V to all media cards, control board, switch board, and backplane. Remember that the GRF 1600 chassis does not have a power on/off switch. When you plug the AC power supply cord into a live outlet, the
GRF powers on and, since the software is already loaded, immediately begins to boot.
Figure 2-6 shows the front of an AC power supply drawer and its locking tab components.
Locking tab in down (unlocked) position
When locking tab is down, power plug cannot be inserted
Power supply air intake fan
100-240V
CAUTION: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords.
ACHTUNG: Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollständig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
ATTENTION: Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
Warning label is placed face-up on the horizontal edge below the intake fan.
Locking tab in up (locked) position
Drawer handle
Sliding plate
Finger lift
When locking tab is up, power plug can be inserted
Figure 2-6. Front of GRF 1600 AC power supply drawer and locking tab
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 2-13
Getting Acquainted with the GRF 1600
Description of the AC power supplies
AC drawer locking tab
The AC power supply drawers have a locking mechanisn that prevents anyone from removing a drawer while the unit has a power cord plugged in. Refer to the diagram below.
Before you plug the cord into the power supply, you can see that a plate covers part of the AC receptacle. You can easily slide this plate up to insert the cord. The locking tab stays up in the locked position and prevents the drawer from being pulled out while the power cord is plugged in.
The locking tab is at the top edge of the sliding plate. Immediately below the sliding plate and at either side of the receptacle are two small screws. These screws attach the AC receptacle to the drawer front. They also are used to attach a power cord clamp. The screws can be untightened 3 or 4 turns to allow the clamp to slide under, but they should never be fully removed.
Locking tab in up (locked) position
Drawer handle
Sliding plate
Finger lift
When locking tab is up, power plug can be inserted
How to obtain a clamp
Lucent does not supply cord clamps. Clamps are available from the Panel Components
Corporation, P/N 85910051, at (515) 673-5000.
AC power supply safety considerations
Caution: The power supplies contain hazardous voltages and energy levels.
• Do not attempt to service yourself. Refer all servicing to qualified personnel.
• Double-pole/neutral fusing.
Vorsicht : In den Netzteilen liegen Hochspannung und gefährliche Energiepegel an.
• Versuchen Sie nicht, das Gerät selbst zu warten. Alle Reparaturarbeiten sind von
Fachkräften auszuführen.
• Zweipolige/Neutralleiter-Sicherung
2-14 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 1600
Description of the AC power supplies
Redundant AC supply safety considerations
If the GRF is equipped with redundant AC power supplies, please note the following when powering on (plugging in) and powering off (unplugging) the GRF unit:
Caution: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords. Care must be taken to correctly connect each power supply to separate AC power sources and (optional) UPS devices.
Vorsicht : Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollstandig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
Achten Sie darauf, daß jedes Stromkabel mit einer separaten Wechselstromquelle und einem separaten USV-Gerät verbunden wird.
Attention : Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
Label requirement
The warning label shown in Figure 2-7 is required when a second power supply is installed in a
pre-existing system to provide redundancy. When a GRF is shipped with a single power supply, this label is not on the power supply unit. If a customer orders a redundant power supply, a set of labels is included, along with instructions to attach a label to each unit.
100-240V
CAUTION: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords.
ACHTUNG: Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollständig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
ATTENTION: Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
Figure 2-7. Warning label required for redundant supplies
The label is actually attached to the top edge of the fastening knob compartment at the bottom of the unit, facing upwards.
Minimum media card load requirement
Redundant GRF 1600 power supplies require a minimum load installed equal to two media cards. If the minimum media card load is not met, the supplies may generate false power supply failure messages. While the power supply units are not damaged during this condition, misleading error messages may be logged in /var/log/grconsole.log
.
When redundant power supplies are installed in a GRF 1600 chassis, you must keep at least two media cards inserted to meet the minimum load requirement. Minimum load can be problematical when power supplies are operating in the redundant or current share mode, particularly on high current output supplies. It is recommended that the GRF 1600 only be operated with at least two media cards installed.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 2-15
Getting Acquainted with the GRF 1600
Description of the 48VDC power supplies
Description of the 48VDC power supplies
The GRF 1600 1100W DC power supply provides +48V to the fans and +5.0V to all media cards, and the control board, switch board, and backplane. Directions for attaching DC input wiring to the DC power supply are in chapter 3.
The GRF 1600 does not have a chassis-based power switch. Instead, each DC power supply has its own on/off switch. You cannot put the switch to on unless the power supply drawer is properly inserted into the chassis. The DC drawer has a locking tab that prevents the drawer from being pulled out while the switch is on. You must switch the power off and drop the
locking tab down before you can remove a power supply. Refer to Figure 2-8.
Locking tab is in down (drawer unlocked) position
On / off switch is locked off
Drawer handle
Power supply air intake fan
Locking tab in up (drawer locked) position
Figure 2-8. Front panel of GRF 1600 DC power supply
2-16 October, 1998
Finger lift
Power supply is locked in place, switch can be on
GRF 400/1600 Getting Started - 1.4 Update 2
Getting Acquainted with the GRF 1600
Description of the 48VDC power supplies
DC drawer locking tab
The DC power supply drawers have a locking mechanisn that prevents anyone from removing
a drawer while the unit is powered on. Refer to Figure 2-8.
The locking tab is at the top edge of the sliding plate. When the power switch is on, the locking tab stays up in the locked position and prevents the drawer from being pulled out. When the power is switched off, the tab drops down and the power supply drawer can be removed.
DC power supply safety considerations
Caution: The power supplies contain hazardous voltages and energy levels.
• Do not attempt to service yourself. Refer all servicing to qualified personnel.
Vorsicht : In den Netzteilen liegen Hochspannung und gefährliche Energiepegel an.
• Versuchen Sie nicht, das Gerät selbst zu warten. Alle Reparaturarbeiten sind von
Fachkräften auszuführen.
Redundant DC supply safety considerations
If the GRF is equipped with redundant DC power supplies, please note the following when powering on and powering off the GRF unit:
Caution: This unit has two power inputs. For total isolation from electrical shock and energy hazard, disconnect both supply inputs. Care must be taken to correctly connect each power supply to separate AC power sources and (optional) UPS devices.
Vorsicht : Dieses Gerät hat zwei Stromeingänge. Um das Gerät vollständig vom Netz zu trennen, unterbrechen Sie den Anschluß mit beiden Eingängen, sonst können Sie einen elektrischen Schlag erhalten. Achten Sie darauf, daß jedes Stromkabel mit einer separaten
Wechselstromquelle und einem separaten USV-Gerät verbunden wird.
Attention : Cet appareil a deux sources d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux sources d’alimentation.
Minimum media card load requirement
Redundant GRF 1600 power supplies require a minimum load installed equal to two media cards. If the minimum media card load is not met, the supplies may generate false power supply failure messages. While the power supply units are not damaged during this condition, misleading error messages may be logged in /var/log/grconsole.log
.
When redundant power supplies are installed in a GRF 1600 chassis, you must keep at least two media cards inserted to meet the minimum load requirement. Minimum load can be problematical when power supplies are operating in the redundant or current share mode, particularly on high current output supplies. It is recommended that the GRF 1600 only be operated with at least two media cards installed.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 2-17
Getting Acquainted with the GRF 1600
Installation preview
Installation preview
Now that you are familiar with the GRF 1600, this page gives you a preview of the tasks you will do to install the GRF, and what the other chapters in this Getting Started manual cover:
1 Rack mount and ground the GRF chassis. (chapter 3)
2 Insert any additional media cards. The GRF is shipped with all ordered media cards installed, if you have others to install, insert them now. (chapter 3)
3 Attach a VT 100-compatible terminal or laptop PC to the serial port (RS-232) on the GRF control board. The terminal is used to enter the initial IP configuration information and to monitor system boot. Later you can connect the GRF to the administrative Ethernet and disconnect the terminal. (chapter 3)
4 Power on the GRF by plugging in the AC power supply or wiring the DC power supply.
The GRF has no on/off switch, and ships with software already loaded. When you apply current to the power supplies, the GRF begins to boot. Watch the control board LEDs to see the status of the system during and after boot. (chapter 3)
5 The first time a GRF is powered on, a configuration script automatically runs. The script prompts you to enter the router’s system IP address and host name. You must supply this information to communicate with the GRF and to later connect the GRF to your administrative Ethernet. (chapter 4)
The script also prompts you to begin to configure remote logging by setting up a syslog server. If you choose to configure “local” logging to a PCMCIA device, just press the
<Enter> key at those prompts.
6 Log in as root . Optionally, you can change the preset password for root . (chapter 4)
7 Configure logging, there are several options. Procedures to set up local PCMCIA and network logging are in this manual. (chapter 4)
Optionally, you can install and configure a PCMCIA modem connection to the GRF.
8 Connect the GRF maintenance Ethernet interface to your site’s administrative LAN. Use the Ethernet connector on the control board. If you like, you can now disconnect the VT
100 terminal. (chapter 4)
9 Attach the media card cables. (chapter 5)
At the end of this Getting Started manual, you are ready to configure the media card interfaces, network services, and protocols. This information is covered in the GRF Configuration and
Management manual.
2-18 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
3
Chapter 3 describes how to rack mount and power on the GRF routers, including both AC and
DC power supplies. The first half covers the GRF 400, the second half covers the GRF 1600.
GRF set up is organized so that you attach media cables after power on and watch the progress of the control board and media card LEDs for indications of normal or error conditions.
Chapter 3 includes these topics:
Interpreting GRF 400 control board LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Interpreting GRF 1600 control board LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
Applying AC power to the GRF 1600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24
Applying DC power to the GRF 1600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
Note: The GRF 400 and GRF 1600 are static sensitive. An ESD wrist strap must be worn when you move or otherwise touch the chassis. Each chassis has a wrist strap ground site for connecting your wrist strap.
GRF 400
Wrist strap grounding sites
GRF 1600
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-1
Rack Mount and Power On Procedures
Rack mounting the GRF 400
Rack mounting the GRF 400
Before you begin installing the GRF 400, make sure you have these items:
– A VT-100 terminal to attach to the control board RS-232 port
– A locally-connected host or workstation that can ping the GRF
– Media cables appropriate to the media cards that were ordered
– If applicable, any media cards that shipped separately
Servicing clearances
Media cards and power supply drawers are 16 inches long. You need three feet of working space to access and remove hot-swappable components at the GRF 400 cable panel.
Power and ground requirements
!
Caution: If using a power strip or similar supply, make sure the power requirements of the chassis, plus the cumulative power draw of any other equipment in the rack, do not overload the supply circuit.
Vorsicht : Wird ein Sammelstecker oder ähnlicher Netzanschluß verwendet, ist darauf zu achten, daß die Stromerfordernisse des Rahmens gemeinsam mit dem kumulativen
Stromverbrauch anderer Geräte auf dem Regal den Versorgungsschaltkreis nicht überbelasten.
Warning: For safe operation, this equipment must be properly grounded.
– The chassis should be reliably earth grounded to the rack equipment.
– This earth ground connection must be maintained when supply connection is other than direct connection to the branch circuit.
Warnung: Zur Gewährleistung eines sicheren Betriebs muß dieses Gerät vorschriftsmäßig geerdet sein.
– Der Geräterahmen muß richtig am Regalbauteil geerdet sein.
– Dieser Masseanschluß muß bewahrt werden, wenn die Stromversorgung nicht direkt
über den Anschluß an den Abzweigstromkreis erfolgt.
3-2 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Rack mounting the GRF 400
Rack-mounting requirements
If you are rack-mounting the GRF 400 base unit:
– Always stack the rack from the bottom up to ensure a stable and safe rack.
– The installation of GRF 400 and other units within the rack should not reduce the air flow within the rack. The maximum recommended ambient temperature for the GRF
400 is 40˚ C (104˚ F).
– Make sure you have a two-unit air gap for cooling and cables between the GRF and any other equipment installed in the rack.
– Determine that the cumulative power requirements of the GRF 400 plus other equipment in the rack do not overload the rack supply circuit and/or wiring.
Ventilation requirements
When installing, please consider the location of the GRF in relation to other devices located in an adjacent rack. Ensure that the GRF’s air intake is not drawing directly upon heated air from
another unit. Figure 3-1 shows air intake and exhaust areas. When you install the GRF, you
must provide six to ten inches of side clearance.
Intake fans
Heated air Ambient air
Figure 3-1. Air intake and exhaust areas of the GRF 400
Ventilation must comply with these requirements:
– The installation of the GRF 400 and other units within the rack should not reduce the air flow within the rack. The maximum recommended ambient temperature for the
GRF is 40˚ C (104˚ F).
– Make sure you have a two-unit air gap for cooling and cables between the GRF and any other equipment in the rack.
What to do next...
If you have media cards that are not inserted in the GRF, insert them now. Go on to the next section, “Inserting a media card.”
With the chassis securely in place and media cards inserted, the next step is to attach a terminal to the GRF. Go to the section “Attaching a VT-100 terminal.”
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-3
Rack Mount and Power On Procedures
Inserting a media card
Inserting a media card
Note: To operate properly, a GRF 400 should have at least one media card installed.
Note: Also, a face plate cover must be installed in any unused slot to maintain cooling flows.
Media cards are actually two logic boards joined to make a single component. As shown in
Figure 3-9, the smaller board on the right is the serial interface, also called the serial daughter
card. The larger one on the left is the media board and has the network ports. Together they comprise a GRF media card. The GRF 400 and 1600 use the same media cards.
The media card serial and part numbers are printed at the lower edge of the card, near the bottom finger grip/extractor.
Ports
A
ATM
3c
B
ATM
OC-3c
SM
Media board
Serial/rev number area
Serial daughter card
Horizontally level for GRF 400
Top Bottom
(g0143)
ATM
3c
Vertically upright for
GRF
1600
A
B
ATM
OC-3c
SM
Figure 3-2. Media card components
The boards are joined by two 100-pin connectors and reinforcing plates. Even so, this joint retains some flex and must be carefully supported, especially when inserting the media card into a chassis.
Warning: The backplanes of both the GRF 400 and the GRF 1600 contain hazardous energy levels.
When replacing a media card, remove only one card at a time. Removing more than one card will expose the operator to this energy hazard.
Warnung : An den Rückwandplatinen des GRF 400 und GRF 1600 liegen gefährliche
Hochspannungen ab.
Zum Auswechseln der Medienkarte jeweils nur eine Karte entfernen. Bei zwei gleichzeitig entfernten Karten ist der Bediener gefährlichen Spannungen ausgesetzt.
3-4 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Inserting a media card
ESD requirements
!
Caution: GRF media cards are hot swappable and can be installed when the GRF is running.
However, media card are highly susceptible to damage from electrostatic discharge, you must wear a grounded, conductive wrist strap anytime you handle a media card.
Wear a grounded, conductive wrist strap when removing, replacing, and/or handling individual electronic components. Make sure the metallic elements in the band directly touch your exposed skin.
GRF 1600
GRF 400
Wrist strap grounding sites
Insertion procedure
1 When you are properly grounded, remove the media card from its anti-static container.
2 Hold the media card with the network ports facing you.
GRF 400
Turn the card horizontal, the top of the media card should be on the left, the bottom of the card should be on the right. As you start, make sure you visually identify the left and right guide pair for this particular slot.
Keeping the media card horizontally level, insert the card fully into the slot, you will feel the card joining with the 100-pin connector on the backplane.
3 When fully inserted, the card’s face plate should be flush against the chassis back panel.
Note: Do not force the card into the slot. Doing so can damage the card or slot connector.
4 Tighten the screws at each end of the face plate.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-5
Rack Mount and Power On Procedures
Attaching a VT-100 terminal
Attaching a VT-100 terminal
You must connect the VT-100 compatible terminal to the control board’s RS-232 serial port
BEFORE you power on the GRF. After the system boots, you will enter system IP and host name configuration information in the first time power on script from the terminal. This task is described in chapter 4.
You can stay at the terminal to perform the rest of the system configuration or you can connect the GRF to the administrative Ethernet LAN and continue configuration from there. After the
GRF can be accessed from the administrative Ethernet, the serial connection is no longer required.
PCMCIA slots A and B Reset button Speaker to external LAN to VT-100
S COM BU ETHERNET
Figure 3-3. Connectors on a control board
As shown in Figure 3-10, the control board provides multiple connection sites. Use a null
modem cable (console cross-over cable) to attach the terminal to the RS-232 serial connector site. (A GRF 400 control board is shown here, the GRF 1600 serial port is the same.)
VT-100 terminal settings
Terminal settings are 9600 bits/second, 8-bits, no parity, 1 stop bit
Laptop PC
You can attach a laptop PC that meets the following requirements:
– Windows 3.11 or Windows/NT operating system
– a VT 100 terminal emulation program set to the proper communication port
– settings of 9600 bits/second, 8-bits, no parity, 1 stop bit
What to do next...
With the terminal attached to the serial port, go on to “Powering on the GRF 400.”
3-6 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Powering on the GRF 400
Powering on the GRF 400
As described earlier in this chapter, the initial start-up of the GRF requires a directly-attached terminal for logging in as root . This terminal should be connected before you power on the
GRF so you can monitor the start up and boot messages that begin immediately.
The GRF 400 is powered by either AC or negative 48V DC power supplies.
This section includes procedures for both types of power supply:
– applying power to AC power supplies
– wiring and applying power to DC power supplies
The GRF chassis does not have a power on/off switch. When the power cord is plugged in to a power outlet or when the DC wiring set is connected to a source supply, the GRF is powered on. It takes a few seconds for the power supply(s) to cycle before power is supplied to the back panel and the media cards.
When the GRF is powered on, it begins to boot. You can see the boot messages displayed on the VT-100 screen. As it boots, the GRF runs a series of internal diagnostics. The first time a
GRF is powered on, the boot process runs a system configuration script. In this script you assign the GRF a host name, configure the maintenance Ethernet, and optionally specify a
syslog server. The GRF supports remote logging via a syslog server as well as local logging
(and dumps) to an external flash device.
Media cards will boot automatically and come up ready to operate.
The speaker on the control board faceplate emits audible beeps as the board boots.
Redundant power supplies
Installing redundant power supplies ensures against failures of individual units in the chassis.
If possible, attach each power supply into a different power source.
Power supply failure notification
If a GRF power supply fails, you will see failure messages on-screen at the user interface. The gr.console
log file will also contain related messages. The PS1 or PS2 amber LED on the control board will light, indicating a power supply failure. If you do not already have a replacement unit, order one from Lucent.
Warning: A failed power supply must be replaced by certified personnel only.
Warnung : Das Netzteil darf nur von einer Fachkraft ausgewechselt werden.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-7
Rack Mount and Power On Procedures
Interpreting GRF 400 control board LEDs
Interpreting GRF 400 control board LEDs
S COM BU ETHERNET
Figure 3-4. GRF 400 control board faceplate and LEDs
Table 3-1. Descriptions of GRF 400 control board LEDs
LED Description
POWER
FAULT
This green LED is on when the GRF power is on.
This amber LED flashes once as the board starts self-test; then flashes once again when self-test completes. If the Fault LED turns on and remains on, an error condition has been detected.
STATUS
COM BUS ACTIVE
COM BUS TRANSMIT This green LED flashes during bus activity.
COM BUS RECEIVE This green LED flashes during bus activity.
PS1-OK
This green LED is on and flashes a “heartbeat” during positive board operation.
This green LED flashes during bus activity.
PS2-OK
This green LED is on when power supply 1 is operating at required level. If the power supply fails, the LED goes off.
This green LED is on when power supply 2 is operating at required level. If the power supply fails, the LED goes off.
This green LED is on while the Ethernet connection from the control board is good. LINK OK
100 This green LED is on when the Ethernet is in 100Base-T mode. The LED is off under
10Base-T mode.
XMT ACT
RCV ACT
This green LED flashes while data is sent to the management software.
This green LED flashes while data is received from the management software.
During start-up, media card “PWR” LEDs come on green. This manual is organized so that you attach cables after power on and can watch the progress of each card’s LEDs for indication of normal or error conditions. Chapter 5 contains descriptions of all media card LEDs.
3-8 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Applying AC power to the GRF 400
Applying AC power to the GRF 400
The GRF 400 does not have an on/off switch. Therefore, you must first plug the power cord into the AC power supply BEFORE you plug the cord into a wall or other receptacle.
!
Caution: The power supplies contain hazardous voltages and energy levels.
• Do not attempt to service a unit yourself. Refer all servicing to qualified personnel.
• Double-pole/neutral fusing.
• For continued protection against risk of fire, replace only with the same type and rating of fuses. Replace F3 and F4 only with recognized 6.3A, 250V, fast-acting fuses. Replace F5 only with 5.0A, 250V, fast-acting fuse.
Vorsicht : In den Netzteilen liegen Hochspannung und gefährliche Energiepegel an.
• Versuchen Sie nicht, das Gerät selbst zu warten. Alle Reparaturarbeiten sind von
Fachkräften auszuführen.
• Zweipolige/Neutralleiter-Sicherung
• Nur mit Sicherungen des gleichen Typs und der gleichen Leistung ersetzen, um jegliche
Feuergefahr zu vermeiden. F3 und F4 nur mit anerkannten Schnellsicherungen mit 6,3 A,
250 V, ersetzen. F5 nur mit Schnellsicherungen mit 5,0 A, 250 V, ersetzen.
Plug-in steps
Here are the plug-in steps for AC power supplies shipped in your GRF 400:
1 Start with the AC power cord NOT plugged into the power source.
2 Check that the power supply unit is pushed fully into the chassis.
3 Connect the power cord into the AC receptacle on the power supply drawer.
4 Last, plug the power cord into the appropriate rack or wall outlet.
A note about redundant AC supplies
When the GRF 400 is equipped with redundant AC power supplies, please note the following when powering on (plugging) or powering off (unplugging) the GRF unit:
Caution: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords. Care must be taken to correctly connect each power supply to separate AC power sources and (optional) UPS devices.
Vorsicht : Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollständig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
Achten Sie darauf, daß jedes Stromkabel mit einer separaten Wechselstromquelle und einem separaten USV-Gerät verbunden wird.
Attention : Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-9
Rack Mount and Power On Procedures
Applying AC power to the GRF 400
Labeling a redundant AC power supply
The warning label shown in Figure 3-5 is required when a second power supply is installed in a
pre-existing system to provide redundancy. When a GRF is shipped with a single power supply, this label will not be on the power supply unit. If a customer orders a redundant power supply, a set of labels is included, along with instructions to attach a label to each unit.
Astec label
!
CAUTION: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords.
ACHTUNG: Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollständig von
Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
Artesyn
label
100-240V
CAUTION: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords.
ACHTUNG: Dieses Gerät hat zwei
Netzanschlusskabel. Um das Gerät vollständig von Netz zu trennen ziehen
Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
ATTENTION: Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc
électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
Figure 3-5. Warning label required for redundant AC supplies
Replacing a redundant AC power supply
If you need to replace one of a redundant set of AC power supplies, remember that there are incompatibilities between two brands of AC power supplies used in GRF 400s. You must make sure that you do not mix Astec and Artesyn units.
Specific information about and an illustration of each type of AC unit are provided in chapter 1, please refer to that chapter before you order or install a replacement unit.
What to do next...
With the terminal attached to the serial port and AC power applied to the GRF 400, the system has automatically booted. Go to the next chapter. Chapter 4 describes the first-time configuration script and initial system tasks that bring the GRF to an operational state, ready for media card cabling and verification.
3-10 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Applying DC power to the GRF 400
Applying DC power to the GRF 400
Site installation requirements
!
!
Warning: The DC power supply must be installed only in restricted access areas
(dedicated equipment rooms, equipment closets, or the like) in accordance with Articles
110-16, 110-17, and 110-18 of the National Electric Code, ANSI/NFPA 70.
Connect to a 48V DC source which is electrically isolated from the AC source and which is reliably connected to earth.
This equipment is designed to permit the connection of the grounded conductor of the DC supply circuit to the grounding conductor at the equipment. If this connection is made, all of the following conditions must be met:
• This equipment shall be connected directly to the DC supply system grounding electrode conductor or bonding jumper from a grounding terminal bar or bus to which the DC supply system grounding electrode conductor is connected.
• This equipment shall be located in the same immediate area (such as adjacent cabinets) as any other equipment that has a connection between the grounded conductor of the same
DC supply circuit and the grounding conductor, and also the point of grounding of the DC system. The DC system shall not be grounded elsewhere.
• The DC supply source is to be located within the same premises as the equipment.
• There shall be no switching or disconnecting devices in the grounded circuit conductor between the DC source and the point of connection of the grounding electrode conductor.
• All DC input wiring shall be routed away from any sharp edges and properly secured in place to prevent chaffing and to provide strain relief. This may be achieved by tie wrapping the wires to the rack frame or by equivalent means.
Warning: A readily accessible disconnect device must be provided in the fixed wiring for a
DC power supply. It must be suitable for the rated voltage and current specified.
Warnung : In der Festverdrahtung für ein Gleichstromnetzteil muß ein leicht zugänglicher
Trennschalter vorgesehen werden. Er muß für die angegebene Nennspannung und den
Nennstrom geeignet sein.
Warning: Over-current and earth fault protection must be provided in the fixed wiring. This protection must be sized accordingly to interrupt the maximum available fault current.
Warnung : Überstrom- und Erdschlußschutz muß in der Festverdrahtung vorhanden sein. Zur
Unterbrechung von maximal vorhandenem Fehlerstrom muß dieser Schutz von der entsprechenden Größenklasse sein.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-11
Rack Mount and Power On Procedures
Applying DC power to the GRF 400
DC terminals
Figure 3-6 shows the four terminals on the front of the -48V DC (negative) power supply
drawer. Lucent ships the DC unit fitted with an aluminum cover over the terminal area. The cover is flipped up to attach the DC input wiring. After the DC unit is properly wired, you must also secure the cover using the two screws.
Please read through the steps before you begin, refer to Figure 3-6 as you review.
Cover area
!
!
Figure 3-6. Front of -48V power supply drawer.
Caution: The first terminal on the left is a NEGATIVE 48V. The second terminal from the left is NEGATIVE 48V Return.
Vorsicht : Der erste Anschluß links ist 48V MINUS. Der zweite Anschluß von links ist die
Rückleitung mit 48V MINUS.
When you connect DC wires, remember that the first terminal on the left is NEGATIVE 48V.
The second terminal from the left is NEGATIVE 48V “RETURN.”
If you connect the two DC wires incorrectly, you blow the input fuses —the DC power supply will not work now. The power supplies may only be serviced by a qualified trained service technician.
Always connect a protective earth ground to the terminal with this label:
Site alarm option
!
The right-most terminal, labeled “ALARM”, enables you to attach the DC power supply to a site alarm unit. If power fails to reach the backplane of the GRF 400, an internal relay activates and applies the RETURN for the -48V to the site alarm terminal. This output is fused at 0.5A.
When wiring this output, use only UL-recognized terminal lug and conductor suitably rated for the voltage and current.
3-12 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Applying DC power to the GRF 400
Wiring procedure
Here are the steps to attach a wire set to a GRF 400 DC power supply:
1 Do not have the DC wire set attached to a power source.
The GRF 400 does not have an on or off switch, and a “live” wire will immediately apply power. Shut off the DC source before you begin to attach any wires.
2 Check that the power supply drawers are pushed fully into the chassis. Undo the two screws from the aluminum cover and flip the cover back.
3 Attach wires in this order: a. Connect a protective earth ground to the terminal with this symbol: b. Attach the negative 48V wire to the first terminal on the left, it is marked “-48V.” c. Attach the negative 48V return to the terminal marked “RETURN.”
When you connect DC wires, remember that the first terminal on the left is NEGATIVE 48V.
The second terminal from the left is NEGATIVE 48V “RETURN.” If you connect the two DC wires incorrectly, you blow the input fuses —the DC power supply will not work now. The power supplies may only be serviced by a qualified trained service technician.
4 If you are connecting the GRF to a site alarm unit, connect the alarm unit to the right-most terminal, labeled “ALARM.” If power fails to reach the backplane of the GRF 400, an internal relay activates and applies the RETURN for the -48V to the site alarm terminal.
This output is fused at 0.5A.
5 Flip the cover back down and replace the two screws.
6 Connect the DC wire set connector to the power source. The GRF will start up and boot.
Fuses
!
Caution: The power supplies contain hazardous voltages and energy levels.
• Do not attempt to service a unit yourself. Refer all servicing to qualified personnel.
• Double-pole/neutral fusing.
• For continued protection against risk of fire, replace only with the same type and rating of fuses. Replace F3 and F4 only with recognized 10.0A, 250V, fast-acting fuses. Replace F5 only with 0.5A, 250V, fast-acting fuse.
Vorsicht : In den Netzteilen liegen Hochspannung und gefährliche Energiepegel an.
• Versuchen Sie nicht, das Gerät selbst zu warten. Alle Reparaturarbeiten sind von
Fachkräften auszuführen.
• Zweipolige/Neutralleiter-Sicherung
• Nur mit Sicherungen des gleichen Typs und der gleichen Leistung ersetzen, um jegliche
Feuergefahr zu vermeiden. F3 und F4 nur mit anerkannten Schnellsicherungen mit 10,0 A,
250 V, ersetzen. F5 nur mit Schnellsicherungen mit 0,5 A, 250 V, ersetzen.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-13
Rack Mount and Power On Procedures
Applying DC power to the GRF 400
Redundant DC supply safety considerations
The notice shown below appears on the lower edge of the GRF 400 DC power supply:
!
SEE INSTRUCTION MANUAL and refers to the following caution:
If the GRF is equipped with redundant DC power supplies, please note the following when powering off (disconnecting) the GRF unit:
Caution: This unit has two power inputs. For total isolation from electrical shock and energy hazard, disconnect both power inputs. Care must be taken to correctly connect each power supply to separate power sources and (optional) UPS devices.
Vorsicht : Dieses Gerät hat zwei Stromeingänge. Um das Gerät vollständig vom Netz zu trennen, unterbrechen Sie den Anschluß mit beiden Eingängen, sonst können Sie einen elektrischen Schlag erhalten. Achten Sie darauf, daß jedes Stromkabel mit einer separaten
Wechselstromquelle und einem separaten USV-Gerät verbunden wird.
Attention : Cet appareil a deux sources d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux sources d’alimentation.
What to do next...
With the terminal attached to the serial port and DC power applied to the GRF 400, the system has automatically booted. Go to the next chapter. Chapter 4 describes the first-time configuration script and initial system tasks that bring the GRF to an operational state, ready for media card cabling and verification.
3-14 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Powering off a GRF 400
Powering off a GRF 400
The GRF 400 does not have an on/off switch. To power down a GRF system, first use the
shutdown command to cleanly shut down the operating system:
# shutdown -r now
Systems with AC power supplies
After you execute the shutdown command, unplug the the AC power cord from the receptacle or other power source.
If the GRF is equipped with redundant AC power supplies, please note the following when powering off the unit:
Caution: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords. Care must be taken to correctly connect each power supply to separate AC power sources and (optional) UPS devices.
Vorsicht : Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollstandig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
Achten Sie darauf, daß jedes Stromkabel mit einer separaten Wechselstromquelle und einem separaten USV-Gerät verbunden wird.
Attention : Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
GRFs with DC power supplies
After you execute the shutdown command, use the disconnect device in the site’s fixed wiring to shut off current from the DC source.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-15
Rack Mount and Power On Procedures
Rack mounting the GRF 1600
Rack mounting the GRF 1600
Before you begin installation, make sure you have these items:
– A VT-100 terminal to attach to the control board RS-232 port
– A locally-connected host or workstation that can ping the GRF
– Media cables appropriate to the media cards that were ordered
– If applicable, any media cards that shipped separately
Servicing clearances
Media cards and power supply drawers are 16 inches long. You need three feet of working space to access and remove hot-swappable components at the GRF 1600 cable panel.
Grounding
The GRF 1600 has a rack grounding terminal on the lower right side of the cable panel. Also on the right side, above the power supply units, there is a wrist strap ground receptacle.
Warning: For safe operation, this equipment must be properly grounded.
The chassis should be reliably earth grounded to the rack equipment.
This earth ground connection must be maintained when supply connection is other than direct connection to the branch circuit.
Warnung: Zur Gewährleistung eines sicheren Betriebs muß dieses Gerät vorschriftsmäßig geerdet sein.
Der Geräterahmen muß richtig am Regalbauteil geerdet sein.
Dieser Masseanschluß muß bewahrt werden, wenn die Stromversorgung nicht direkt über den Anschluß an den Abzweigstromkreis erfolgt.
Power requirements
Determine that the cumulative power requirements of the GRF 1600 plus other equipment in the rack do not overload the supply circuit and/or wiring of the rack.
!
Caution: If using a power strip or similar supply, make sure the power requirements of the chassis, plus the cumulative power draw of any other equipment in the rack, do not overload the supply circuit.
Vorsicht : Wird ein Sammelstecker oder ähnlicher Netzanschluß verwendet, ist darauf zu achten, daß die Stromerfordernisse des Rahmens gemeinsam mit dem kumulativen
Stromverbrauch anderer Geräte auf dem Regal den Versorgungsschaltkreis nicht überbelasten.
3-16 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Rack mounting the GRF 1600
Ventilation requirements
Ventilation must comply with these requirements:
– The installation of the GRF 1600 and other units within the rack should not reduce the air flow within the rack. The maximum recommended ambient temperature for the
GRF is 40˚ C (104˚ F).
– Make sure you have a two-unit air gap for cooling and cables between the GRF and any other equipment in the rack.
Additionally, please consider the location of the GRF 1600 in relation to other devices located in an adjacent rack. Ensure that the GRF’s air intake is not drawing directly upon heated air
from another unit. Figure 3-7 shows air intake and exhaust areas. When you install the GRF,
you must provide six to ten inches of side clearance.
Heated air exhaust
Heated air exhaust
Exhaust fans
Side intake Side intake
Ambient air intake Ambient air intake
Figure 3-7. Air intake and exhaust areas of the GRF 1600
Rack depth
If the media cards require flat cables, the minimum rack depth required to install a GRF 1600 is
26” (66.7 cm), and the rack must be EMI/RFI shielded.
If the media cards require round, shielded cable, the minimum rack depth should be 27” (69 cm).
Side rails
– If you rack-mount the GRF 1600, Lucent recommends you install side rails in the rack before attempting to insert a GRF 1600. Side rails support the 107-124 pound unit as the team inserts the chassis and fastens it to the rack. The internal width of the
GRF 1600 chassis is 17.375” (44.1 cm).
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-17
Rack Mount and Power On Procedures
Rack mounting the GRF 1600
Rack-mounting procedure
!
ALWAYS stack the rack from the bottom up to ensure a stable and safe rack.
Caution: Because of its weight, installing the GRF 1600 into a rack requires a two-person team.
Vorsicht : Aufgrund seines Gewichts sind zur Installation des GRF 1600 auf dem Regal zwei
Personen erforderlich.
You need two people to safely maneuver the GRF 1600 into a standard 19” rack. First, make sure the rack will not roll or otherwise move. One person should stand on each side of the chassis. Use the handholds on the chassis side to carry the weight of the unit.
This stick figure drawing illustrates how to support the chassis as you insert it.
– Both people use the handholds to carry most of the weight.
– The person on the left keeps their other hand under the front of the chassis, supporting the weight and making sure it doesn’t tip down.
– The person on the right has their other hand on the top of the unit, keeping the unit properly balanced.
Side rail
Handhold - support weight
Rack support
Handhold - support weight
Bottom of chassis - support Top - balance chassis
Figure 3-8. Diagram of proper way to move GRF 1600 into rack
To start, position the lower edges of the chassis on the side rails. Slide the chassis in until the hands using the handholds are at the rack support with the side rails supporting the GRF weight. Let go of the handholds, push the chassis in three or four inches till the handholds are past the rack supports, then use the handholds as necessary to push the chassis all the way in.
What to do next...
If you have media cards that are not inserted in the GRF, insert them now. Go on to the next section, “Inserting a media card.”
With the chassis securely in place and media cards inserted, the next step is to attach a terminal to the GRF. Go to the section “Attaching a VT-100 terminal.”
3-18 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Inserting a media card
Inserting a media card
Note: To operate properly, a GRF 1600 requires that a minimum of two media cards be installed.
Note: Also, a face plate cover must be installed in any unused slot to maintain cooling flows.
Media cards are actually two logic boards joined to make a single component. As shown in
Figure 3-9, the smaller board on the right is the serial interface, also called the serial daughter
card. The larger one on the left is the media board and has the network ports. Together they comprise a GRF media card. The GRF 400 and 1600 use the same media cards.
The media card serial and part numbers are printed at the lower edge of the card, near the bottom finger grip/extractor.
Ports
A
ATM
3c
B
ATM
OC-3c
SM
Media board
Serial/rev number area
Serial daughter card
Horizontally level for GRF 400
Top Bottom
(g0143)
ATM
3c
Vertically upright for
GRF
1600
A
B
ATM
OC-3c
SM
Figure 3-9. Media card components
The boards are joined by two 100-pin connectors and reinforcing plates. Even so, this joint retains some flex and must be carefully supported, especially when inserting the media card into a chassis.
Warning: The backplanes of both the GRF 400 and the GRF 1600 contain hazardous energy levels.
When replacing a media card, remove only one card at a time. Removing more than one card will expose the operator to this energy hazard.
Warnung : An den Rückwandplatinen des GRF 400 und GRF 1600 liegen gefährliche
Hochspannungen ab.
Zum Auswechseln der Medienkarte jeweils nur eine Karte entfernen. Bei zwei gleichzeitig entfernten Karten ist der Bediener gefährlichen Spannungen ausgesetzt.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-19
Rack Mount and Power On Procedures
Inserting a media card
ESD requirements
!
Caution: GRF media cards are hot swappable and can be installed when the GRF is running.
However, media card are highly susceptible to damage from electrostatic discharge, you must wear a grounded, conductive wrist strap anytime you handle a media card.
Wear a grounded, conductive wrist strap when removing, replacing, and/or handling individual electronic components. Make sure the metallic elements in the band directly touch your exposed skin.
GRF 1600
GRF 400
Wrist strap grounding sites
Insertion procedure
1 When you are properly grounded, remove the media card from its anti-static container.
2 Hold the media card with the network ports facing you.
GRF 1600
As you start, make sure you visually identify the top and bottom guide pair for this particular slot. Have one hand under the card, lightly supporting its weight. Rest just the edge of the bottom corner of the card in the bottom guide. Then, bring the top edge of the card into the top guide. This will help you keep the card level as you slide it in.
Keeping the media card vertically upright, insert the card fully into the slot.
You will feel the card joining with the 100-pin connector on the backplane.
3 When fully inserted, the card’s face plate should be flush against the chassis back panel.
Note: Do not force the card into the slot. Doing so can damage the card or slot connector.
4 Tighten the screws at each end of the face plate.
3-20 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Attaching a VT-100 terminal
Attaching a VT-100 terminal
You must connect the VT-100 compatible terminal to the control board’s RS-232 serial port
BEFORE you power on the GRF. After the system boots, you will enter system IP and host name configuration information in the first time power on script from the terminal. This task is described in chapter 4.
You can stay at the terminal to perform the rest of the system configuration or you can connect the GRF to the administrative Ethernet and continue configuration from there. After the GRF can be accessed from the administrative Ethernet, the serial connection is no longer required.
PCMCIA slots A and B Reset button Speaker to external LAN to VT-100
S COM BU ETHERNET
Figure 3-10. Connectors on a control board
As shown in Figure 3-10, the control board provides multiple connection sites. Use a null
modem cable (console cross-over cable) to attach the terminal to the RS-232 serial connector site. (A GRF 400 control board is shown here, the GRF 1600 serial port is the same.)
VT-100 terminal settings
Terminal settings are 9600 bits/second, 8-bits, no parity, 1 stop bit
Laptop PC
You can attach a laptop PC that meets the following requirements:
– Windows 3.11 or Windows/NT operating system
– a VT 100 terminal emulation program set to the proper communication port
– settings of 9600 bits/second, 8-bits, no parity, 1 stop bit
What to do next...
With the terminal attached to the serial port, go on to “Powering on the GRF 1600.”
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-21
Rack Mount and Power On Procedures
Powering on the GRF 1600
Powering on the GRF 1600
As described earlier in this chapter, the initial start-up of the GRF requires a directly-attached terminal for logging in as root . The terminal should be connected BEFORE you power on the
GRF so you can monitor the start up and boot messages that begin immediately. The GRF 1600 is powered by either 1100W AC or negative 48V DC power supplies.
This section includes procedures for both types of power supply:
– applying power to AC power supplies
The GRF chassis does not have a power on/off switch. The AC power supply does not have an on/off switch. As a result, when the AC power cord is plugged in to a power outlet, the GRF is powered on. It takes a few seconds for the power supply(s) to cycle before power is supplied to the back panel and the media cards.
– wiring and applying power to DC power supplies
A GRF 1600 DC power supply does have a power on/off switch on its front panel. After the DC wiring set is attached and carries current, this switch controls the application of current to the DC power supply.
When the GRF is powered on, it begins to boot. You can see the boot messages displayed on the terminal screen. As it boots, the GRF runs a series of internal diagnostics. The first time a
GRF is powered on, the boot process runs a system configuration script. In this script you assign the GRF a host name, configure the maintenance Ethernet, and optionally specify a
syslog server. The GRF supports remote logging via a syslog server as well as local logging
(and dumps) to an external flash device.
Media cards will boot automatically and come up ready to operate.
The speaker on the control board faceplate emits audible beeps as the board boots.
Redundant power supplies
Installing redundant power supplies ensures against failures of individual units in the chassis.
If possible, attach each power supply into a different power source.
Power supply failure notification
If a GRF 1600 power supply fails, you will see failure messages on-screen at the user interface.
The gr.console
log file will also contain related messages. The PS1 or PS2 amber LED on the control board will light, indicating a power supply failure. If you do not already have a replacement unit, order one from Lucent.
3-22 October, 1998
Warning: A failed power supply must be replaced by certified personnel only.
Warnung : Das Netzteil darf nur von einer Fachkraft ausgewechselt werden.
GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Interpreting GRF 1600 control board LEDs
Interpreting GRF 1600 control board LEDs
COM B US T F AUL
ETHERNET
• • • • •
• • • •
Figure 3-11. GRF 1600 control board faceplate and LEDs
Table 3-2. Descriptions of GRF 1600 control board LEDs
LED
POWER
PCMCIA
STATUS
ACT
RCV
XMT
FAN
TEMP
PS1 and PS2
LINK OK
100
XMT ACT
RCV ACT
Description
This green LED is on when the GRF power is on.
This green LED lights when either PCMCIA slot is in use.
This green LED is on and flashes a “heartbeat” once a second during positive board operation.
This green LED flashes during com bus activity.
This green LED flashes during com bus activity.
This green LED flashes during com bus activity.
This amber LED is off during normal fan operation. FAN comes on when either Fan1 or Fan2, or both, failed.
This amber LED remains off while temperature level is acceptable. TEMP comes on if operating temperature level is exceeded. You will also hear an alarm.
This amber LED is on when a power supply failure is detected. The LED is normally off when the power supply is operating correctly.
This green LED is on while the Ethernet connection from the control board is good.
This green LED is on while the 100BaseT link is operating and off under 10Base-T mode.
This green LED flashes while data is sent to admin node.
This green LED flashes as data is received from admin node.
During start-up, media card “PWR” LEDs come on green. This manual is organized so that you attach cables after power on and can watch the progress of each card’s LEDs for signs of normal or error conditions. Chapter 5 contains descriptions of all media card LEDs.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-23
Rack Mount and Power On Procedures
Applying AC power to the GRF 1600
Applying AC power to the GRF 1600
The GRF 1600 chassis does not have an on/off switch. Therefore, plug the AC power cord into the unit’s AC power supply BEFORE you plug the cord into a wall or other receptacle.
You can obtain and install a power cord locking clamp to prevent the power cord from being accidentally pulled out of the AC power supply.
!
Caution: The power supplies contain hazardous voltages and energy levels.
• Do not attempt to service a unit yourself. Refer all servicing to qualified personnel.
• Double-pole/neutral fusing.
• For continued protection against risk of fire, replace only with the same type and rating of fuses. Replace F3 and F4 only with recognized 6.3A, 250V, fast-acting fuses. Replace F5 only with 5.0A, 250V, fast-acting fuse.
Vorsicht : In den Netzteilen liegen Hochspannung und gefährliche Energiepegel an.
• Versuchen Sie nicht, das Gerät selbst zu warten. Alle Reparaturarbeiten sind von
Fachkräften auszuführen.
• Zweipolige/Neutralleiter-Sicherung
• Nur mit Sicherungen des gleichen Typs und der gleichen Leistung ersetzen, um jegliche
Feuergefahr zu vermeiden. F3 und F4 nur mit anerkannten Schnellsicherungen mit 6,3 A,
250 V, ersetzen. F5 nur mit Schnellsicherungen mit 5,0 A, 250 V, ersetzen.
Plug-in steps
Here are the power on steps with AC power supplies installed in your GRF 1600:
1 Start with the AC power cord NOT plugged into the power source.
2 Check that the power supply drawer is pushed fully into the GRF chassis.
3 If you are using a locking clamp to secure the power cord, refer to the next section,
“Installing a power cord locking clamp”, for instructions to install the clamp.
4 Connect the power cord into the AC receptacle on the power supply drawer.
5 Last, plug the power cord into the appropriate rack or wall outlet.
Installing a power cord locking clamp
3-24 October, 1998
Warning: If the power supply is equipped with a power cord clamp, the socket outlet must be located near the equipment and shall be easily accessible. The power cord shall have a maximum length of 3 meters (10 feet).
This warning is important because in an emergency, the only safe way to remove power from the GRF is to unplug it at the wall or socket outlet. In effect, if a clamp is used, the wall or socket outlet serves as the GRF’s AC disconnect.
GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Applying AC power to the GRF 1600
Warnung : Wenn das Netzteil mit einer Netzkabelklemme ausgestattet ist, muß sich die
Steckdose nahe dem Gerät befinden und leicht zugänglich sein. Das Netzkabel darf nicht länger als 3 m sein.
Dieser Warnhinweis ist sehr wichtig, da die Stromversorgung des GRF in einem Notfall nur durch Herausziehen des Netzsteckers von der Wandsteckdose getrennt werden kann. Bei
Verwendung einer Klemme dient die Wandsteckdose oder Steckdose zum Ausschalten des
GRF.
Figure 3-12 shows the clamp itself and also as it installed on the AC power supply drawer.
Clamp, in upright position, ready to attach
Retaining ear
Sliding plate
Receptacle screw
Clamp screw
Figure 3-12. AC power supply with a power cord locking clamp installed
A receptacle screw is on each side of the AC receptacle on the power supply unit. The primary purpose of these screws is to attach the AC receptacle to the drawer front. They can also be used to attach a power cord clamp.
The screws can be untightened 3 or 4 turns, enough to slide the clamp under, but should
NEVER be fully removed since their primary purpose is to hold the AC receptacle unit in place. DO NOT COMPLETELY REMOVE THE SCREWS.
Install the cord clamp before you plug the cord into either the GRF or the outlet.
Clamp procedure
1 First, slip the clamp over the cord connector, then lift the sliding plate and plug in the connector.
2 Loosen the receptacle screws just far enough to slide the clamp retaining ears underneath.
DO NOT COMPLETELY REMOVE THE SCREWS.
3 Tighten the screws.
4 Now you can plug the cord into the AC source.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-25
Rack Mount and Power On Procedures
Applying AC power to the GRF 1600
How to obtain a clamp
Lucent does not supply cord clamps. Clamps are available from the Panel Components
Corporation, P/N 85910051, at (515) 673-5000.
A note about redundant AC supplies
When the GRF 1600 is equipped with redundant AC power supplies, please note the following when powering on (plugging in) or powering off (unplugging) the GRF unit:
Caution: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords. Care must be taken to correctly connect each power supply to separate AC power sources and (optional) UPS devices.
Vorsicht : Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollständig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
Achten Sie darauf, daß jedes Stromkabel mit einer separaten Wechselstromquelle und einem separaten USV-Gerät verbunden wird.
Attention : Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
Labeling a redundant AC power supply
The warning label shown in Figure 3-13 is required when a second power supply is installed in
a pre-existing system to provide redundancy. When a GRF is shipped with a single AC power supply, this label will not be on the power supply unit. If a customer orders a redundant AC power supply, a set of labels is included, along with instructions to attach a label to each unit.
100-240V
CAUTION: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords.
ACHTUNG: Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollständig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
ATTENTION: Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
Figure 3-13. Warning label required for redundant supplies
What to do next...
With the terminal attached to the serial port and AC power applied to the GRF 1600, the system has automatically booted. Go to the next chapter. Chapter 4 describes the first-time configuration script and initial system tasks that bring the GRF to an operational state, ready for media card cabling and verification.
3-26 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Applying DC power to the GRF 1600
Applying DC power to the GRF 1600
Site installation requirements
!
Warning: The DC power supply must be installed only in restricted access areas
(dedicated equipment rooms, equipment closets, or the like) in accordance with Articles
110-16, 110-17, and 110-18 of the National Electric Code, ANSI/NFPA 70.
Connect to a 48V DC source which is electrically isolated from the AC source and which is reliably connected to earth.
!
This equipment is designed to permit the connection of the grounded conductor of the DC supply circuit to the grounding conductor at the equipment. If this connection is made, all of the following conditions must be met:
• This equipment shall be connected directly to the DC supply system grounding electrode conductor or bonding jumper from a grounding terminal bar or bus to which the DC supply system grounding electrode conductor is connected.
• This equipment shall be located in the same immediate area (such as adjacent cabinets) as any other equipment that has a connection between the grounded conductor of the same
DC supply circuit and the grounding conductor, and also the point of grounding of the DC system. The DC system shall not be grounded elsewhere.
• The DC supply source is to be located within the same premises as the equipment.
• There shall be no switching or disconnecting devices in the grounded circuit conductor between the DC source and the point of connection of the grounding electrode conductor.
• All DC input wiring shall be routed away from any sharp edges and properly secured in place to prevent chaffing and to provide strain relief. This may be achieved by tie wrapping the wires to the rack frame or by equivalent means.
Warning: A readily accessible disconnect device must be provided in the fixed wiring for a
DC power supply. It must be suitable for the rated voltage and current specified.
Warnung : In der Festverdrahtung für ein Gleichstromnetzteil muß ein leicht zugänglicher
Trennschalter vorgesehen werden. Er muß für die angegebene Nennspannung und den
Nennstrom geeignet sein.
Warning: Over-current and earth fault protection must be provided in the fixed wiring. This protection must be sized accordingly to interrupt the maximum available fault current.
Warnung : Überstrom- und Erdschlußschutz muß in der Festverdrahtung vorhanden sein. Zur
Unterbrechung von maximal vorhandenem Fehlerstrom muß dieser Schutz von der entsprechenden Größenklasse sein.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-27
Rack Mount and Power On Procedures
Applying DC power to the GRF 1600
!
Caution: The power supplies contain hazardous voltages and energy levels.
• Do not attempt to service a unit yourself. Refer all servicing to qualified personnel.
Vorsicht : In den Netzteilen liegen Hochspannung und gefährliche Energiepegel an.
• Versuchen Sie nicht, das Gerät selbst zu warten. Alle Reparaturarbeiten sind von
Fachkräften auszuführen.
DC terminals
Lucent ships the DC unit fitted with an aluminum cover over the terminal area. Remove the two screws securing the cover to attach the DC input wiring. After the DC unit is properly wired, you must close the cover and replace the two screws.
Figure 3-14 shows the three terminal pairs on the front of the 48V DC (negative) power supply
drawer. The NEGATIVE 48V and POSITIVE 48V terminal pairs are circled.
!
Warning: If you connect the NEGATIVE and POSITIVE DC wires incorrectly, damage to the power supply may result and it will not function. The power supplies may only be serviced by a qualified trained service technician.
Wiring the DC supply
Before you begin, please read through the steps and refer to Figure 3-14 and Figure 3-15.
Wire and lug requirements:
• Use AWG #6 stranded copper wire.
• Use two-hole, short barrel copper lugs with 1/4 inch stud
—Thomas & Betts, P/N 54205, or equivalent.
• Wire and lug must be UL Recognized and CSA Certified.
• Crimp wire and barrel using the correct crimping tool, Thomas & Betts hand crimper P/N
TBM20S, or a crimper specified for use with equivalent lug.
Always connect a protective earth ground to the terminal pair with this label:
3-28 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Applying DC power to the GRF 1600
Ground terminal pair
NEGATIVE 48V terminal pair
POSITIVE 48V terminal pair
Figure 3-14. Terminal pairs on GRF 1600 DC power supply
Wiring procedure:
1 Disconnect power to the cables that you will attach to the DC power supply. Check that the power supply switch is set to off and that the power supply drawers are pushed fully into the chassis.
2 Undo the two screws from the aluminum cover and swing the cover open.
3 Remove the top hex nut and copper washer from each terminal.
4 Attach two-hole lug wires in this order: a. a protective earth ground wire to the pair markedwith this symbol: b. to the NEGATIVE 48V terminal pair marked “–”. c. to the POSITIVE 48V terminal pair marked “+”.
5 Replace the copper washer first, then tighten the hex nut on each terminal. Torque hardware between 20- and 24-in. lbs.
6 Close the cover and replace the two screws.
7 Apply power to the wires.
8 Lift the tab and press the power switch to on. The GRF will start up and boot.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-29
Rack Mount and Power On Procedures
Applying DC power to the GRF 1600
Figure 3-15 shows the DC terminals when fully wired.
On / off switch is locked off
Locking tab is in down (drawer unlocked) position
Figure 3-15. DC supply wires attached to GRF 1600 DC terminal pairs
Locking tab
The GRF 1600 DC power supply has a locking tab that unlocks the power drawer only when the switch in the off position. When the switch is in the off position, the switch cannot be set on without lifting the tab and locking the power drawer in the chassis. When the switch is in the on position, it can easily be switched off.
3-30 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Rack Mount and Power On Procedures
Applying DC power to the GRF 1600
Labeling a redundant DC power supply
The warning label shown in Figure 3-16 is required when a second DC power supply is
installed in a pre-existing GRF 1600 to provide redundancy.
When a GRF is shipped with a single power supply, this label will not be on the power supply unit. If later a customer orders a redundant power supply, a set of labels is included, along with instructions to attach a label to each unit.
This notice must appear on the DC power supply terminal cover in the space enclosed by dotted lines. Hash marks are provided at two corners to help you position the new label.
!
The DC power supply must be installed in restricted access areas (dedicated equipment rooms, equipment closets, or the like). Connected to a 48VDC source which is electrically isolated from the AC source and which is reliably connected to earth.
GND
48VDC
RTN
!
See instruction manual.
48VDC
Figure 3-16. Warning label required for redundant DC power supply cover
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 3-31
Rack Mount and Power On Procedures
Powering off a GRF 1600
Powering off a GRF 1600
The GRF 1600 does not have an on/off switch. To power down a GRF system, first use the
shutdown command to cleanly shut down the operating system:
# shutdown -r now
Systems with AC power supplies
After you execute the shutdown command, unplug the the AC power cord from the receptacle or other power source.
If the GRF is equipped with redundant AC power supplies, please note the following when powering off the unit:
Caution: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords. Care must be taken to correctly connect each power supply to separate AC power sources and (optional) UPS devices.
Vorsicht : Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollstandig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
Achten Sie darauf, daß jedes Stromkabel mit einer separaten Wechselstromquelle und einem separaten USV-Gerät verbunden wird.
Attention : Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
GRFs with DC power supplies
After you execute the shutdown command, push the DC power supply switch to the off position. If you are going to remove the supply wiring, you must use the disconnect device in the site’s fixed wiring to shut off current from the DC source.
What to do next...
With the terminal attached to the serial port and DC power applied to the GRF 1600, the system has automatically booted. Go to the next chapter. Chapter 4 describes the first-time configuration script and initial system tasks that bring the GRF to an operational state, ready for media card cabling and verification.
3-32 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
4
Chapter 4 describes the first-time configuration script and initial system tasks that bring the
GRF to an operational state, ready for media card cabling and verification. The procedures are the same for the GRF 400 and the GRF 1600, any differences are noted.
The tasks described in this chapter are:
– Establishing initial communication using the first-time configuration script.
(This is done over the VT-100 terminal already attached, see chapter 3.)
– Logging on as root.
– Configuring logging to an external device.
(This can be done at the VT-100 or in a telnet session from the administrative LAN.)
Chapter 4 covers the following topics:
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-1
Initial System Set-up
First communication with the router
First communication with the router
This section describes what you see at the terminal after you power on a GRF.
When you plug in the GRF, it powers on and begins to boot. Boot activity is displayed on the screen.
First-time power on configuration script
The first-time configuration script runs automatically only at this time. It only runs again when invoked.
The script prompts for the following information:
– host name for GRF.
– whether you wish to configure the maintenance Ethernet interface de0 at this time.
– IP address for maintenance Ethernet interface de0
(The GRF is shipped with a temporary de0 network address set to 192.0.2.1
, but you should configure your site address now.).
– netmask for maintenance Ethernet interface de0 IP address.
– if you want a default (static) route to another router on the maintenance Ethernet.
– that router’s IP address.
You can see your answers when they are displayed at the end of the script. You have the option to rerun the script to make changes or to simply drop your responses:
You have now answered all the questions necessary for basic network configuration. If you didn't make any mistakes while entering your answers, simply continue and the appropriate configuration files will be created.
If you wish to exit this program without writing out the configuration files, type <Control>-C.
Your current answers are:
Host Name: grf.tester.com
IP Address: 192.168.160.133
Ethernet interface: de0 (Digital DC33333/22222/11111)
Special Netmask:
Default Route: (none)
Do you wish to go through the questions again? [yes]
Enter no if you have no changes. The script automatically saves your entries to the appropriate configuration file.
The de0 reference is to the internal name for the control board’s Ethernet interface through which the GRF connects to your site’s maintenace/administrative LAN. You will see an entry for de0 in the /etc/grifconfig.conf
configuration file when you add media card interface and IP address information to that file, the script enters the de0 entry as it completes.
4-2 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
Logging in as root
Changing the configuration script later
If later you need to change any of the information you entered in the first-time configuration script, you can run the script again. Enter:
# config_netstart
The script will run again and will re-prompt for the same information as the first time.
Logging in as root
This section describes the root log in to the GRF. The root log in is the UNIX-equivalent super user. The first log in while you are connected using the VT-100 terminal must be a root log in.
After you connect the GRF to the local Ethernet, the root log in is not required. Normally you will telnet to the GRF and use the administrative log in.
After the configuration script completes, you are prompted to press the Enter key.
When you do, the User: prompt appears for the first log in.
You need to log in as user root . The preset password for root is Ascend (with a capital A).
Here is the process:
Press <Enter> to continue.
User:
At the User prompt, type: root
User: root
Password:
Use the preset password, type: Ascend (Ascend with a capital A)
Password: • • • • • •
When a password is entered, it is not echoed (displayed) on the screen.
The super> prompt appears: super>
The super> prompt indicates you are in the Command Line Interface (CLI), and are logged in as root . When you log in to a GRF as root , you automatically get the CLI shell. In the
CLI, root is super user, hence the super> prompt.
Changing the root password
GRF systems are shipped with Ascend (capital A) preset as the root password. As a security precaution, Customer Support recommends that you change this preset password now, before you begin system configuration.
If you are at the super> prompt, you are in the CLI. You need to be in the UNIX shell to change the password. Use sh to invoke the UNIX shell. Each time you start the shell, you see the Lucent copyright and version notice. Type exit to leave the shell.
At the super> prompt, execute the sh command to create a UNIX shell, the UNIX # prompt appears: super> sh
#
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-3
Initial System Set-up
The de0 interface
At the # prompt, type: passwd and you are prompted to enter the old password:
# passwd
Old password:
Enter the new password twice, as prompted: (use at least eight alphanumeric characters)
New password: • • • • • • • • • •
Retype new password: • • • • • • • • • •
#
The de0 interface
The de0 interface is the physical Ethernet interface on the GRF control board. de0 is for out of band access. It is not another Ethernet interface for routing packets. This interface is only to be used for administrative and maintenance access to the GRF. You should, for example, use de0 for syslog server or NFS mounts.
Traffic through de0 travels on the internal communications bus (com bus). The com bus can efficiently handle control and configuration data, but no other type.
As a result, there are requirements for de0 :
– de0 should have a non-routable IP address, this will prevent hard-to-detect problems.
– Default routes must not go through de0 .
– Never run any dynamic routing protocols on de0 .
– Never use de0 as an ATMP address.
The GRF is shipped with a temporary de0 network address set to 192.0.2.1
. If you did not enter your site address in the first-time configuration script, de0 has that address.
grifconfig and netstart de0 addresses must match
The first-time power on configuration script prompts you for a host name for the GRF and an
IP address. This IP address is automatically assigned to the de0 interface and placed in both the /etc/grifconfig.conf
and /etc/netstart files.
Therefore, if you change de0 ’s IP address in one of these files, you must also change it in the other. If the two addresses do not match, GateD does not install the multicast address to de0 on boot and has problems routing to the multicast address.
4-4 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
Attaching the maintenance interface de0
Attaching the maintenance interface de0
The control board supports the maintenance connection to the GRF from a site’s local administrative Ethernet. This is the recommended mode of access for GRF system management and administration.
In the first-time configuration script, you entered the IP address and netmask for the maintenance interface de0 . This section describes how to connect that interface to your local
Ethernet LAN.
Ethernet connection to control board
The control board faceplate has an RJ-45 modular connector. It supports 10 or 100 megabit
connections and autosenses the line rate. As indicated in Figure 4-1, the Ethernet connector is
prohibited from telco lines.
Ethernet to external LAN Address: 192.0.2.1
ETHERNET
Figure 4-1. Point-to-point Ethernet connector on the control board
The maintenance Ethernet connector site is labeled “100/10,” its network interface is de0.
To connect to an external Ethernet LAN, insert the LAN cable into the receptacle marked
“100/10.” Its address is already configured in the first-time configuration script.
Using telnet
When you telnet to the GRF from a workstation on the maintenance LAN, you must use the administrative account “ netstar ” to log into the GRF router.
After you connect the GRF to the local Ethernet, the root log in is not required. Normally you will telnet to the GRF and use the administrative log in.
After you log in, test your network access and administrative account on the router after configuring it on your LAN.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-5
Initial System Set-up
Administrative log on
Administrative log on
After you attach the Ethernet de0 connection from an administrative LAN to the control board, you can telnet from your administrative station to the GRF using the IP address assigned in the configuration script. For normal day-to-day operations, you will likely use the administrative log in, not the root.
At the User : prompt, enter: netstar (all lowercase)
At the Password : prompt, enter: NetStar (capital N, capital S, one word)
User: netstar
Password: • • • • • • •
#
Change to superuser.
At the # UNIX prompt, enter: su (all lowercase)
# su
At the Password : prompt, enter the new root password you created or enter Ascend if you have not changed the preset password:
Password: • • • • • • super>
The super> prompt indicates you are in the command-line interface (CLI).
CLI and UNIX passwords
The UNIX logins described here have passwords associated with UNIX user accounts. These passwords are different from the CLI user profile password. The CLI auth command controls permissions for CLI user logins. A user can log in to the CLI by using the auth command to return a password prompt. If the user supplies the correct password, then the CLI permissions specified for the user are granted.
When you log into the GRF, it uses UNIX authentication. You cannot telnet using a user profile name or password. When you enter the CLI, it automatically assigns you a CLI authentication as “super” if you logged in as root, otherwise, it assigns “default”. You can display your CLI authentication with the whoami command. Your CLI authentication affects which fields you can see and which commands you can invoke within the CLI.
The next task is to learn about the GRF user interface. You have already used its primary components, the Command Line Interface and the UNIX shell.
4-6 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
Overview of GRF user interface components
Overview of GRF user interface components
This overview is intended to help you understand what is happening in the procedures that make up the rest of this chapter. The procedures use both the Command Line Interface (CLI) and the UNIX shell. As you do the procedures, you will use CLI commands and will also open a UNIX shell and edit configuration files or execute UNIX commands.
Configuration tasks - shell or CLI ?
To configure and manage the GRF, you will use both the CLI command set and the UNIX shell. You switch between them, there are no nested levels of shell and CLI.
You must be in the UNIX shell to edit the /etc/xxx.conf
configuration files. The /etc directory contains the configuration files.
Otherwise, many system management and configuration commands are available in the CLI as well as the UNIX shell. Enter a “?” to retrieve a list of CLI commands. All system commands are described in the GRF Reference Guide.
The GRF user environment consists of two main components, the CLI and the UNIX shell.
There is also a set of low-level maint commands.
Command Line Interface (CLI)
The Command Line Interface, usually called CLI, supports a set of profiles and a large set of
GRF and UNIX-like commands. There are five profiles that contain parameters for five areas:
– System profile, includes the GRF host name, the de0 IP address, and various hardware characteristics.
– Card profile, includes media type, protocol, port parameters, ICMP/dump/load settings. Each card has its own Card profile.
– User profile(s), a profile for each defined user, includes access, password
– Dump profile, defines system-wide dump events and storage. (Some dump parameters can be customized for a card in its Card profile.)
– Load profile, defines the running binaries for each control and media card type. (Some load parameters can be customized for a card in its Card profile.)
Profiles and their parameters are described in detail in the GRF Configuration and
Management manual.
The GRF UNIX-like system management and configuration commands are available in the
CLI. At the CLI prompt (usually super> ) enter a “?” to retrieve the list of available commands. Refer to the GRF Reference Guide for a description of each CLI command.
When you log in to a GRF as root , you automatically get the CLI shell. In the CLI, root is super user, hence the super> prompt.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-7
Initial System Set-up
Overview of GRF user interface components
UNIX shell
While in the CLI you use the sh command to open a UNIX shell. The shell supports standard
UNIX commands and the GRF UNIX-like commands. You can manage the GRF using the
UNIX network and configuration management commands. The GRF also has a number of configuration files that you edit with a UNIX editor, you must be in the shell to edit GRF configuration files.
To configure and manage the GRF, you will use both the CLI command set and the UNIX shell. Type exit to leave the shell. When you exit the UNIX shell, you can execute CLI-only commands.
maint commands
A third component is the set of maint commands specific to each media card. The maint commands display low-level card-specific statistics and counts. These commands are documented within each media card’s configuration chapter in the GRF Configuration and
Management manual. The HSSI card maint commands are in the “HSSI Configuration” chapter, for example.
As noted, this is a brief overview. The “Working in the GRF User Interface” chapter in the
GRF Configuration and Management manual provides information and examples using the
CLI profiles and commands.
What to do next...
The next step is to configure logging. What you do depends upon the option you have chosen for external logging. The options are described in this order:
– “local” logging and dumping to an external PCMCIA flash device
– remote logging (over the network) to a syslog server
– remote logging (over the network) to an NFS-mounted file system
4-8 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
About GRF logs and dumps
About GRF logs and dumps
Logs
When the GRF first boots and loads, logging is not enabled. System memory restrictions on the
GRF control board require that logging be to external storage. If target external storage is not specified to receive log entries, log entries are not saved. You should configure logging as part of initial system set up.
There are three options for logging. Procedures for each are in the next several sections:
– “local” logging and dumping to an external PCMCIA flash device inserted in the control board
– remote logging (network) to a syslog server
– remote logging (network) to an NFS-mounted file system
Three logs provide specific information useful for monitoring and debugging GRF operations.
If you are working with Customer Support, these are the three logs they will need to see:
– /var/log/gr.console
– /var/log/gr.boot
– /var/log/messages
The gr.console
log is the most useful log (also called grconslog or the conslog). You will need the information logged to this file to manage the GRF. It contains status and events for the
GRF system and all media cards. When a media card resets, many events of the resetting are reported, including initializing, loading run-time code, requesting and reading configuration parameters, and so on. At the end, you see a message that indicates the cause of the reset.
The grconslog command opens a window to the log that displays messages as they are logged.
It is common practice to telnet into the GRF, enter grconslog -vf , and keep the window open to monitor ongoing system events as they are reported. Use the abort or equivalent key to quit the log. The gr.console.log
displays all types of events including card resets and panics, user log ons, and configuration changes. Refer to the GRF Reference Guide for a description of grconslog options.
The gr.boot
log contains events reported during system and media card boot. These can be helpful if a card has problems booting and coming up.
The messages log contains system-related events connected usually with the management software, also referred to as RMS (Router Management System), and the operating system kernel.
Examples of logs are in the “Management Commands and Tools” chapter of the GRF
Configuration and Management manual. Other log files in the /var/log directory collect low-level information useful primarily to system developers.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-9
Initial System Set-up
About GRF logs and dumps
Accessing a log file
To display the contents of a specific log file, change directory to /var/log and use the more command to display the contents of a specific log file. To access output of grconsole log, use this sequence of commands:
# cd /var/log
# more gr.console
Dumps
The GRF compresses dumps to save space, compressed files are appended with .gz
.
Dumps provide specific information useful for monitoring and debugging GRF operations. If you are working with Customer Support, they may ask for a system or media card dump. The procedure to install a PCMCIA device for logging also specifies that dumps be sent to the device.
System dump
If the GRF is reset or it panics, a dump is saved in the /var/crash directory under the naming convention bsdx.core
where x is the number of the dump, 1, 2, 3...and so on. A system dump is usually too large to send by e-mail. Customer Support will tell you how to send it to them.
The grsavecore command copies and formats information generated from a kernel panic as the data is written to standard output. The formatted data is written to grsavecore.out
in the
/var/crash directory.
Media card dumps
The grdump program saves and manages media card dumps. By default, two dumps are saved per day for each media card. Dumps are collected from media cards when they panic or when they are reset by the system administrator using grreset -D (this command instructs the media card to dump when it comes back up).
Media card dumps are stored in /var/portcards in a file named with the convention grdump.n.x.gz where n is the card slot number and x is the number of the saved dump, 1, 2,
3....
A media card dump is generally 4–8MB, and can sometimes be e-mailed. Customer Support will tell you how to send it to them.
Panic dumps sent to external storage
The mountf and grdump commands enable the grdump program to work with an external storage device to capture media card dumps.
When a media card panics and there is a formatted external flash device plugged into either
PCMCIA slot, a copy of the dump is automatically saved under the portcards directory of the external flash.
4-10 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
Option 1: Log and dump to a PCMCIA device
Option 1: Log and dump to a PCMCIA device
Logging can be done either remotely or locally to an external PCMCIA device.
Because system memory (RAM) provides a fixed amount of log storage, upgrading GRF RAM increases storage for route tables and other routing data, but does not provide additional space to store logs and dumps. Logs and dumps can be sent either to an external flash device inserted in either PCMCIA slot or to a spinning disk device inserted in PCMCIA slot A.
You can install a PCMCIA device any time after the GRF is powered on and is running.
However, logging is not enabled until you install the device and complete this configuration procedure. Since logged messages can be helpful while you are bringing up and configuring media cards, it is recommended you configure logging now.
Use the procedure in this section to ready the PCMCIA device and to send logs and dumps to the device. The procedure is done only once to set up local logs and dumps, and is not affected by software updates or system reboots.
Note that the external PCMCIA device is used only for storage. You cannot boot the GRF router from an external device.
List of devices
Lucent certifies the following ATA-compliant devices for GRF operation:
– Kingston Datapak 520MB, P/N CT520RM
– Sandisk 175MB Flash, P/N SDP3B
– Sandisk 85MB Flash, P/N SDP3B-85-101
– Aved 85MB Flash, P/N AVEF385MB25ATA501
Lucent offers only the 85 MB Flash directly (GRF-AC-FLASH). Customers may purchase the other devices through an external source.
ATA Type-II device dimensions are 85.6 mm x 54.0 mm x 5.0 mm. ATA Type-III device dimensions are 85.6 mm x 54.0 mm x 10.5 mm.
PCMCIA slot commands
Three commands enable remote management of PCMCIA slots. The csconfig slot_number command returns status of each PCMCIA slot. The csconfig slot_number up and csconfig
slot_number down commands mark the specified PCMCIA slot up or down, respectively. An example is included in the device installation procedure which follows.
Do not remove a mounted PCMCIA device from the slot, unmount it first. You will get an error message if you remove a mounted device.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-11
Initial System Set-up
Installing a PCMCIA device
Installing a PCMCIA device
The procedure formats and initializes an external device (flash or disk), temporarily mounts it on /mnt , creates subdirectories and symbolic links, and creates a permanent site file for storing the symbolic links. The example installs a flash device into slot A and specifies that logs and dumps be sent to directories on the device. You do not need to specify whether the device is a flash or spinning disk.
The PCMCIA device is named according to the slot it occupies:
– /dev/wd2a , the device residing in slot A (often a spinning disk)
– /dev/wd3a , the device residing in slot B (a flash disk or modem)
1 Insert the PCMCIA device into slot A on the GRF control board.
The thickness of a spinning disk device requires it be installed in slot A. A flash disk or modem can be installed in either A or B.
2 Log in as root to the GRF, start the UNIX shell, and execute these commands from the shell: prompt> sh
#
# cd /
# iflash -A
# mountf -A -w -m /mnt
# mkdir /mnt/crash
# mkdir /mnt/portcards
# cd /var
# mv crash crash.orig
# mv portcards portcards.orig
# ln -s /var/log/portcards /var/portcards
# ln -s /var/log/crash /var/crash
# grsite --perm portcards crash
# cd /var/log
# pax -rw -pe -v . /mnt
# umountf -A
3 Edit the file /etc/fstab :
# cd /etc
# vi fstab
Use the UNIX editor to add this line as shown at the bottom of the excerpt:
/dev/wd2a /var/log ufs rw 0 2 #PCMCIA slot A, use wd3a for B
Here is the portion of the file where you will add the specified line:
# Filesystem mount table information. See the fstab(5) man page
# and the /etc/fstab.sample file for more information and examples.
#
# Each line is of the form:
# device mount_point type flags dump fsck_pass
#
# Note that multiple flags (when used) are specified as a
4-12 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
Installing a PCMCIA device
# comma separated list without spaces.
#
# Blank lines and lines beginning with `#' are comments.
#
/dev/rd0a / ufs rw 0 0
/dev/wd2a /var/log ufs rw 0 2 #PCMCIA slot A, use wd3a for B
4 Edit the file /etc/syslog.conf
to specify the location where the logs will be kept.
After you edit /etc/syslog.conf
, you need to send a HUP signal to syslogd.
When installing a spinning disk or flash disk
Uncomment the local log configuration lines in the “Log messages to Disk” section by removing #disk# from each line and specify /var/log as the directory for each log:
These are the first four lines in the section:
#disk#*.err;*.notice;kern.debug;lpr,auth.info;mail.crit
/var/log/messages
#disk# cron.info /var/log/cron
#disk# local0.info /var/log/gritd.packets
#disk# local1.info /var/log/gr.console
The entries should now look like the following:
*.err;*.notice;kern.debug;lpr,auth.info;mail.crit /var/log/messages cron.info /var/log/cron local0.info /var/log/gritd.packets
local1.info /var/log/gr.console
local2.* /var/log/gr.boot
local3.* /var/log/grinchd.log
local4.* /var/log/gr.conferrs
local5.* /var/log/mib2d.log
Touch the files
Touch each file to create it, here is an example:
#cd /var/log
# touch gritd.packets gr.console gr.boot grinchd.log gr.conferrs mib2d.log
Restart syslogd
Determine the PID (process ID) for the syslog daemon and restart it:
# ps -ax | grep syslogd
# kill -HUP < PID>
Optional task:
Step 5 is only for sites that had previously configured logging to syslogd or NFS.
New installations can go onto Step 6.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-13
Initial System Set-up
Installing a PCMCIA device
5 If you had previously configured your GRF to log messages to a directory other than
/var/log , you changed settings in /etc/grclean.conf
and
/etc/grclean.logs.conf
files. Go back into those files now and change the log directory.
Modify /etc/grclean.conf
and /etc/grclean.logs.conf
to reflect the new log directory.
The /etc/grclean.conf
file specifies which log and dump files the grclean program compresses, archives, and deletes.
The /etc/grclean.conf
file entries should look like the following:
##################################################################
# port card dump files.
################################################################## hold=4 size=1 remove=y local=y logfile=/var/portcards/grdump.*
##################################################################
# cleanup our own log file, if necessary.
##################################################################
DEFAULTS hold=2 local=y size=10000 logfile=/var/log/grclean.log
The /etc/grclean.logs.conf
file is used to set size limits on log files. Here are some sample entries:
******************************************************************
* Log files that used to be archived by the
/etc/{daily|weekly|monthly}
* scripts.
***************************************************************** size=150000 logfile=/var/log/gr.console
size=11000 logfile=/var/log/gr.boot
6 Save all changes and reboot:
# grwrite -v
# reboot -i
7 Verify that the PCMCIA interface and device are up. The csconfig command returns information about both external ports:
# csconfig -a
Slot 0: flags=0x3<UP,RUNNING>
Attached device: wdc2
4-14 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
Installing a PCMCIA device
Manufacturer Name: "Kingston Technology"
Product Name: "DataPak 520"
Function ID: 4 (PC card ATA)
Assigned IRQ: 11
Assigned I/O port1: 0x3d0-0x3df
Slot 1: flags=0x5<UP,EMPTY>
If you specify the slot number ( 0 or 1), csconfig retunrs information about the specified slot. This example looks at the flash disk in slot B:
# csconfig 1
Slot 1: flags=0x3<UP,RUNNING>
Attached device: wdc1
Manufacturer Name: "SunDisk"
Product Name: "SDP"
Additional Info1: "5/3 0.6"
Function ID: 4 (PC card ATA)
Assigned IRQ: 11
Assigned I/O port1: 0x3d0-0x3df
8 To run a quick test, execute the grconslog command. This command verifies that logging is correctly configured, so if it runs, the PCMCIA installation has been performed correctly:
# grconslog
iflash command - caution !
The PCMCIA procedure uses the iflash command. The iflash command determines the geometry of an installed PCMCIA ATA Type-II or Type-III storage device, and can format the device for use in a GRF.
!
Caution: By default, iflash does not initialize a flash that already has a file system installed.
The -f option overrides the check and forces any data on the target device to be overwritten.
Use this option only if you wish to erase the existing contents of a flash device.
When you use iflash without -f, you are informed when there is a file system already on the device and reminded that you must use the -f option to overwrite it. Because of its “force” capability, use the iflash -f command with caution.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-15
Initial System Set-up
Option 2: Set up a syslog server
Option 2: Set up a syslog server
One way to log over the network is to use syslog and set up a remote syslogd server (syslog host). A syslog server is another workstation on the maintenance/administrative LAN that has sufficient memory to store log files. You can configure remote logging during initial installation via the configuration script or you can change to remote logging at any time. Both procedures are described in this section.
In the shell, use a UNIX editor to edit the /etc/syslog.conf
configuration file and set up a remote syslog server. The remote syslog or logging server is another node on your LAN that runs the syslog daemon, syslogd.
The GRF /etc/syslog.conf
file configures the GRF to send log messages to a syslog server on your local network. These logs include: gritd.packets
gr.console
gr.boot
grinchd.log
gr.conferrs
mib2d.log
Follow these steps to configure the GRF and the syslog server for network logging:
1 On the GRF, open the /etc/syslog.conf
file and uncomment these lines in the
“ Log messages to Network” section by removing #net# from each line:
#Log messages to Network
#
#net#*.err;kern.debug;auth.notice;mail.crit @server.domain.com
#net#*.notice;kern.debug;lpr,auth.info;mail.crit
@server.domain.com
#net#cron.info @server.domain.com
#net#local0.info @server.domain.com
#net#local1.info @server.domain.com
#net#local2.* @server.domain.com
#net#local3.* @server.domain.com
#net#local4.* @server.domain.com
#net#local5.* @server.domain.com
While you are still in the /etc/syslog.conf
file, replace all instances of
“ server.domain.com
” with the domain name of the syslog server that will receive the log messages.
2 On the GRF, add the IP address and host name of the syslog server to /etc/hosts.
3 On the GRF, run the grwrite command to save the changes to the /etc configuration files
( /etc/syslog.conf
and /etc/hosts).
4 Now log in to the syslog server and add these file names to the server’s
/etc/syslog.conf
file: local0.info /var/log/gritd.packets
local1.info /var/log/gr.console
local2.* /var/log/gr.boot
local3.* /var/log/grinchd.log
4-16 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
Option 2: Set up a syslog server local4.* /var/log/gr.conferrs
local5.* /var/log/mib2d.log
5 On the syslog server, use the touch command to create the log files in the server’s /var/log directory or wherever log files normally reside on the server:
# cd /var/log/
# touch gritd.packets gr.console gr.boot grinchd.log gr.conferrs mib2d.log
6 On the syslog server, kill and restart syslogd.
syslogd must be running with the -i option to enable "internet listening."
If syslogd is not running with -i , kill it and restart it. The syslogd pid can be found in the file /var/run/syslog.pid
. You will lose any messages sent to syslog during the kill/restart processes.
Note:
/etc/rc is shipped with -i enabled. Users cannot save a modified copy of
/etc/rc . Any changes made are lost at the next reboot.
7 On the GRF, kill and restart syslogd.
Because syslogd is usually run before the domain name server (named) at boot time, you need to add an entry to /etc/hosts that describes the host you want to send to.
Here is a sample entry in /etc/hosts:
222.222.11.93 server.domain.com
Now kill syslogd and restart it with the -i option.
Run grwrite to save changes made to the /etc files.
# grwrite
Note that the grconslog command does not differentiate among multiple log files sent to a single remote syslog server from multiple GRF systems.
This completes the network logging configuration. A copy of the /etc/syslog.conf
file is in the GRF Reference Guide.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-17
Initial System Set-up
Option 3: Use an NFS-mounted file system
Option 3: Use an NFS-mounted file system
The maintenance Ethernet interface de0 must be used for NFS-mounted file systems.
!
Caution: NFS mounting CANNOT be done through a media card interface (for example, gf0yz ). The maintenance interface is specified in the /etc/netstart file as the value assigned to the variable " iface ". This variable defines the external connection to the GRF and is set when the GRF is initially installed.
Setting up NFS on the GRF
You must add the appropriate host and IP information for any NFS server you are using into the /etc/host file if either of the following conditions apply:
– The name server(s) in /etc/resolv.conf point out one of the media card interfaces and are thus unavailable when the mount occurs.
– The name server(s) in /etc/resolv.conf
point to a network that is reachable only through a route off the administrative Ethernet and only when GateD is being run.
That is, if GateD is not active and a route entry exists in grroute.conf
, the
/etc/host entries are not needed.
Note: Programs writing to an NFS-mounted file system will block when the NFS connection to the remote file system is dropped.
4-18 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
Option: Attaching a modem to the GRF
Option: Attaching a modem to the GRF
Although you must connect a VT-100 terminal to do the initial configuration, after that you can install a modem connection.
The GRF supports two modem options. One option is to attach a terminal server to the control board serial port (RS-232) and then attach a modem to the terminal server. Another option is to attach a PCMCIA modem directly into one of the control board PCMCIA (PC-CARD) slots.
The modem connection is lost at reboot and you must dial up again to re-establish it.
Instructions for installing the PCMCIA modem are included here. Perform the configuration procedure after the GRF is powered on and the system has booted.
Installing a PCMCIA modem
PCMCIA modems have been tested and found to work reliably with the GRF and to be compatible with the modem configuration commands specified here.
A recommended modem is:
– US Robotics/MegaHertz 56K PC Card Modem, model xj5560
Although other PCMCIA modems have not been tested, some 56K models may work and be configurable with the GRF.
Unpack the PCMCIA modem and insert the modem card into an open PCMCIA slot on the
GRF control board. Attach the phone cable to the modem card and then connect the RJ-11 connector to your phone line (using the RJ-11 female adaptor provided, if needed).
Configuration procedure
To enable the PCMCIA modem to accept calls, configure it from the VT-100 terminal using the following procedure:
1 Turn off getty on the modem line. Enter:
# vi /etc/ttys
Find this line: tty02 "/usr/libexec/getty t9600-hf" vt100 on secure
Change the " on " to " off " so the line reads: tty02 "/usr/libexec/getty t9600-hf" vt100 off secure
Save the file and then enter:
# kill -HUP 1
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-19
Initial System Set-up
Option: Attaching a modem to the GRF
2 Configure the modem – this procedure assumes you are connecting a USR 56K
PCMCIA modem.
You will enter a series of standard modem at commands. After you enter an at command, you get a response, usually “OK”. If you get an error message, please refer to the user documentation that comes with your modem.
To begin the configuration, enter:
# chown uucp.dialer /dev/tty02 <--- changes owner to uucp with group dialer,
# tip tty02 this allows tip program to open modem device.
at at&f <--- resets modem to factory settings
OK ats0=1 <--- sets answer after one ring
OK at&w <--- stores modem configuration to NVRAM
OK atz <--- resets modem
OK
~. <--- disconnects from tip
3 Now turn getty on for the modem line, this is basically the reverse of step 1. Enter:
# vi /etc/ttys
Find the line that looks like: tty02 "/usr/libexec/getty t9600-hf" vt100 off secure
Change the " off " to " on ": tty02 "/usr/libexec/getty t9600-hf" vt100 on secure
Save the file and then enter:
# kill -HUP 1
Save your changes. Enter:
# grwrite -v
This command saves your changes to the /etc/ttys file to system RAM. The -v option displays the names of files as they change.
4 Verify that the PCMCIA interface and device are up, information about the csconfig command is in the GRF Reference Guide:
# csconfig -a
You should now be able to dial in to your GRF system using the PCMCIA modem.
4-20 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Initial System Set-up
Powering off a GRF
Powering off a GRF
The GRF does not have an on/off switch. To power down a GRF system, first use the
shutdown command to cleanly shut down the operating system:
# shutdown -r now
Systems with AC power supplies
After you execute the shutdown -r now command, unplug the the AC power cord from the receptacle or other power source.
If the GRF is equipped with redundant AC power supplies, please note the following when powering off the unit:
Caution: This unit has two power supply cords. For total isolation from electrical shock and energy hazard, disconnect both supply cords. Care must be taken to correctly connect each power supply to separate AC power sources and (optional) UPS devices.
Vorsicht : Dieses Gerät hat zwei Netzanschlusskabel. Um das Gerät vollstandig von Netz zu trennen ziehen Sie beide Kabel ab, sonst können Sie einen elektrischen Schlag erhalten.
Achten Sie darauf, daß jedes Stromkabel mit einer separaten Wechselstromquelle und einem separaten USV-Gerät verbunden wird.
Attention : Cet appareil a deux cordons d’alimentation électrique. Pour une isolation complète de tout choc électrique et de danger énergétique, débrancher les deux cordons d’alimentation.
Systems with DC power supplies
GRF 400
After you execute the shutdown -r now command, use the disconnect device in the site’s fixed wiring to shut off current from the DC source.
GRF 1600
After you execute the shutdown -r now command, push the DC power supply switch to the off position. If you are going to remove the supply wiring, you must use the disconnect device in the site’s fixed wiring to shut off current from the DC source.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 4-21
Initial System Set-up
What to do next
What to do next
At this point the GRF is powered, the administrative LAN is connected, and you have completed initial system IP configuration using the first-time configuration script. You should also have configured system logging.
The next chapter describes media card cabling requirements and ways to check out and verify those connections. After attaching media card cables, use the GRF Configuration and
Management manual to complete system and media card configuration.
4-22 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
5
Chapter 5 discusses cabling requirements for each type of media card and describes the information provided by each card’s LEDs.
Software release 1.4 does not support the first versions of the ATM OC-3c or FDDI media cards. These cards are informally called ATM Classic and FDDI Classic. Only the hardware-enhanced versions of these cards are supported, ATM/Q and FDDI/Q.
Chapter 5 covers the following topics:
Running media card hardware diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35
ESD requirements
Wear a grounded, conductive wrist strap when removing, replacing, and/or handling individual
GRF electronic components.
Note: Please read the first section, “Returning a media card to Lucent”, before you handle any GRF media card or other board.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-1
Cabling and Verifying Media Cards
Returning a media card to Lucent
Returning a media card to Lucent
If you are upgrading a media card or have a hardware problem with a media card, please use the following procedure to return the media card to Lucent.
1 Obtain a Return Material Authorization (RMA) number from your local or regional
Customer Service (TAC) organization.
RMA numbers are important in tracking boards, they help us improve board quality and design.
2 Correctly package your board.
3 Ship the board to Lucent in Alameda.
Here are the details for each step:
Get an RMA number
These are the local/regional Customer Support centers that handle RMAs:
– In the U.S., call: 800-272-3634
– In Europe, call: (+33) 492 96 5673
– In Australia and Asia Pacific, call: (+61) 3 9656 7000
– In Japan, call: (+81) 3 5325 7397
We will assign your board a number and ticket, usually by FAX.
(You can also request an ESD box !)
Package your board properly
Media cards and boards are easily damaged.
These are the requirements for packaging your media card or board you are returning to
Lucent:
ALWAYS: Always put a media card or board into an antistatic bag.
• In fact, any time a board is not installed in a GRF chassis, it should immediately be put into an antistatic bag.
BEST packaging:
Use the same ESD box/foam liner in which this or a similar board was shipped to you. It is always good to keep a few of these ESD boxes on hand.
• Please call Customer Support, we will ship you an ESD box OVERNIGHT.
• If you don’t have an ESD box from Lucent, you can ship an Lucent board back in another vendor’s box as long as the board is in its antistatic bag.
ACCEPTABLE:
Sturdy cardboard box and foam wrapping.
5-2 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
Returning a media card to Lucent
• Tape the antistatic bag closed so no part of the GRF board can slide out
• Wrap the bag and pad the box with foam
• – NEVER USE PAPER OR PEANUTS – tape the foam around the antistatic bag so the board doesn’t slide between gaps.
• Use a heavy-duty cardboard box, tape securely shut.
Ship via FedEx
Enclose the RMA number and ship via FedEx to:
Lucent Technologies, Inc.
RMA Department
1701 Harbor Bay Parkway
Alameda, CA 94502
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-3
Cabling and Verifying Media Cards
Inserting a media card into the GRF
Inserting a media card into the GRF
ESD requirements
!
Caution: Media cards are hot swappable and can be installed when the GRF is running.
However, media cards are highly susceptible to damage from electrostatic discharge. You must wear a grounded, conductive wrist strap any time you handle a media card. Make sure the metallic elements in the band directly touch your exposed skin.
GRF 1600
GRF 400
Wrist strap connector sites
Minimum load requirement
To operate properly, the GRF 1600 requires that at least two media cards be installed. Also, a face plate cover must be installed in any unused slot to maintain cooling flows.
On-card connectors
Media cards are actually two logic boards joined to make a single component. As shown in
Figure 5-1, the smaller board on the right is the serial interface, also called the serial daughter
card. The larger one on the left is the media board and has the network ports. Together they comprise a GRF media card.
Cards install vertically for 16-card GRF 1600:
Media board
Port
Serial daughter card
Serial/rev number area
Cards install horizontally level for 4-card GRF 400:
Top Bottom
Figure 5-1. Media card components
The two logic boards are joined by a pair of 100-pin connectors and reinforcing plates. Even so, this joint retains some flex and must be carefully supported, especially when inserting the media card into the chassis.
Warning: The backplane of the GRF contains hazardous energy levels. When replacing a media card, remove only one card at a time. Removing more than one card will expose the operator to this energy hazard.
5-4 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
Inserting a media card into the GRF
Warnung : An den Rückwandplatinen der GRF liegen gefährliche Hochspannungen ab. Zum
Auswechseln der Medienkarte jeweils nur eine Karte entfernen. Bei zwei gleichzeitig entfernten Karten ist der Bediener gefährlichen Spannungen ausgesetzt.
Chassis insertion procedure
1 When you are properly grounded, remove the media card from its anti-static container.
2 Hold the media card with the network ports facing you.
4-card router
Turn the card horizontal, the top of the media card should be on the left, the bottom of the card should be on the right. As you start, make sure you visually identify the left and right guide pair for this particular slot.
Keeping the media card horizontally level, insert the card fully into the slot, you will feel the card joining with the 100-pin connector on the backplane.
16-card router
As you start, make sure you visually identify the top and bottom guide pair for this particular slot. Have one hand under the card, lightly supporting its weight. Rest just the edge of the bottom corner of the card in the bottom guide. Then, bring the top edge of the card into the top guide. This will help you keep the card level as you slide it in.
Keeping the media card vertically upright, insert the card fully into the slot.
You will feel the card joining with the 100-pin connector on the backplane.
3 When fully inserted, the card’s face plate should be flush against the chassis back panel.
Note: Do not force the card into the slot. Doing so can damage the card or slot connector.
4 Tighten the screws at each end of the face plate.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-5
Cabling and Verifying Media Cards
Inserting a media card into the GRF
Hot swapping media cards
GRF media cards are hot-swappable per media type. That is, you can swap out a HSSI card and replace it with another HSSI card. When the new HSSI card starts up and boots, it is identified to the system and is ready to be configured. Any IP addresses assigned to the HSSI card removed from slot 5, for example, are automatically assigned to the new HSSI card inserted into slot 5.
If you plan to change the type of media card that will replace the HSSI card, then you must reset the system to re-identify the new card.
After you insert the new type of media card but before you reset the GRF, output from the
grcard command displays the actual media type but also indicates the previous media. This is the grcard output after a FDDI card has been inserted into the newly-vacated slot but before the GRF is reset:
# grcard
0 HSSI running
1 HSSI running
2 FDDI held-reset (ERROR: must be HSSI)
3 HSSI running
Q cards
A /Q card has dedicated hardware support for expanded route table lookup.
For FDDI and ATM cards, the _v2 after in grcard output indicates the card is a /Q version of that type of card. All Ethernet, HSSI, ATM OC-12c, and SONET cards have the /Q hardware although they appear in grcard output as _v1 . There is one version of HIPPI, these cards do not have /Q hardware.
Burning in media card flash memory
grflash provides the ability to upgrade flash code at customer sites. The grflash command reprograms (reburns) the code in internal flash (the boot loader). This is different than updating the system software with a new release. Typically, new software releases are loaded into the system and then downloaded into the specific type of media card, they do not require burning into internal flash. The reburn procedure is done only under direction of Customer Support.
Please work with Customer Support to schedule a session with them in the rare instance that the grflash command is needed. If not carefully and correctly done, the reburn process could disable the memory component and the GRF. A grflash man page is available, and the command is also described in the GRF Reference Guide.
5-6 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
Cabling the media cards
Cabling the media cards
The GRF chassis is shipped with all media cards and the control board installed.
Other than making sure face plate screws are tight, media cards need no attention prior to attaching the media interface cables.
The GRF chassis enclosure must have all access panels in place and secured. All available slots must be filled with media cards or blank face platess.
ESD requirements
Note: Wear a grounded, conductive wrist strap when removing, replacing, and/or handling individual GRF electronic components.
Blank face plates
Note: Blank face plates are installed in all unused slots to maintain correct airflow for cabinet cooling. They must remain in place during system operation.
Cable specifications
All data, signal, and control cables connected to the equipment must be of the shielded type with metallic connector hoods, except for Ethernet cables, fiber optic cables, and power cables, which are unshielded. Connectors with jackscrews should be securely tightened.
GRF media cards use the following industry-standard cables:
Table 5-1. Media card cable specifications
Cables/Card
HSSI
ATM OC-3c multimode
ATM OC-3c single mode
ATM OC-12c multimode
ATM OC-12c single mode
4-port 10/100Base-T
8-port 10/100Base-T
FDDI multi-mode
HIPPI
Description
25 twisted-pair shielded coax cables
62.5/125 micron fiber optic cables
9/125 micron fiber optic cables
62.5/125 micron fiber optic cables
9/125 micron fiber optic cables
Category 5 UTP cables
Category 5 UTP cables
62.5/125 micron multi-mode optic cables
Twisted-pair copper cables in 5-, 25-, or 51-meter lengths.
Lucent certifies the viability of GRF-to-GRF connections using 51-meter cables, and sells HIPPI cables directly.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-7
Cabling and Verifying Media Cards
Cabling the media cards
Table 5-1. Media card cable specifications (continued)
Cables/Card Description
SONET OC-3c multimode 62.5/125 micron fiber optic cables
SONET OC-3c single mode 9/125 micron fiber optic cables
Differences in media card loading
The same GRF system does not always come up the same way each time— cards can load in a different order each time the system is brought up.
This is normal and happens because the boot and load signals can catch different points on the communications bus clock cycle. Moving media cards to different slots can also cause variations. Media cards have different boot and diagnostic programs. For example, HIPPI media cards take significantly less time to load and come up than do FDDI.
Reset GRF when all cables are attached
When all cables are in place, reboot the system. This will also reset all media cards.
Use the shutdown -r now or grms command described at the end of the chapter. That last section describes ways to verify that your media cards are viable even though the system is not yet fully configured.
5-8 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
ATM OC-3c (ATM/Q) media card
ATM OC-3c (ATM/Q) media card
The ATM OC-3c (also called ATM/Q) media card provides two full-duplex interfaces. ATM
OC-3c cards are available in single and multimode versions. The ATM/Q media card has hardware support for large route table look-up.
Note: The ATM OC-3c maint 80 command toggles the single mode laser component on or off. See the “ATM OC-3c Configuration” chapter in the GRF Configuration and Management manual for usage information.
Figure 5-2 shows a single mode ATM OC-3c faceplate, single and multimode faceplates are
the same except that the single mode interfaces have a “LASER ON” LED.
(g0008)
Figure 5-2. ATM OC-3c single mode media card faceplate
LEDs
The top four LEDs on the faceplate indicate card status. The duplex interfaces A and B each
have a set of LEDs. Refer to Table 5-2 for a description of each LED.
Table 5-2. ATM OC-3c LEDs
LED
Power
Fault
STAT 0
STAT 1
RCV ACT
XMIT ACT
LINK OK
LASER ON
Description
This green LED is on when GRF power is on.
This amber LED turns on and remains on if an error condition is detected.
These green LEDs blink during self-test. When self-test completes,
STAT 0 blinks ten times a second and STAT 1 blinks once a second.
STAT 0 and STAT 1 indicate the activity of normal system interrupts. If the media card hangs, they either turn off and remain off, or they turn on and remain on.
This amber LED blinks as ATM cells are received at the interface.
This amber LED blinks as ATM cells are transmitted out of the interface.
This green LED goes on when an optic cable is plugged into an interface and remains on while connection is good at both cable ends.
This green LED provides a safety warning on single mode ATM cards.
One should not look into a laser-active interface component if a cable is not plugged in.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-9
Cabling and Verifying Media Cards
ATM OC-3c (ATM/Q) media card
Laser safety
The ATM OC-3c single mode media card contains a Class 1 laser product. The Class 1 laser diode is an integral part of the transceiver module.
CLASS 1 LASER PRODUCT
KLASSE 1 LASER PRODUKT
(g0079)
Warning: Only authorized service personnel should attempt to repair this equipment. All problem discovery and repair procedures are detailed to allow only subassembly/module level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.
Warnung : Lebenensgefahr Achtung, nur authorisiertes Kundendiestpersonal darf dieses
Geraet reparieren. Alle Fehler- und Reparaturvorschriften sehen nur den Austausch von
Baugruppen oder Module vor. Wegen der Komplexitaet der einzelnen Platinen und
Baugruppen soll niemand versuchen Reparaturen auf der Bauteilebene oder Modifikationen an den Platinen vorzunehmen. Falsche Reparaturen koennen lebensgefaehrlich sein.
Table 5-3 provides technical information about the laser diode on the ATM OC-3c single mode
media cards:
Table 5-3. ATM OC-3c single mode laser information
Manufacturer
Part number
Laser type
Wave length
Output power
Agency approvals
Amp Inc.
269085-1
InGaAsP diode
1310 nm (+/- 50 nm)
Single-mode, -14dBm min., -8dBm max
Multi-mode, -19dBm min., -14dBm max
TUV Rheinland - EN 60950
- EN 60825-1
- EN 60825-2
Complies with 21 CFR 1040.10 and 1040.11
5-10 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
ATM OC-12c media card
ATM OC-12c media card
The GRF supports two ATM OC-12c media cards, version 1 and version 2. The card names you see in CLI profiles, logs, and statistics displays are atm-oc12-v1 and atm-oc12-v2 .
Version 2 has an updated SAR component.
The ATM OC-12c media cards each provide one full-duplex interface. ATM OC-12c cards are available in single and multimode versions. Single mode fiber is 9/125 micron, multimode fiber is referred to as 62.5/125 micron fiber. Single and multimode faceplates are the same except that each single mode faceplate has a “LASER ON” LED.
Figure 5-3 shows the faceplate for a version 1 ATM OC-12c media card. Its revision will be F
(or earlier) for a multimode card, or G (or earlier) for a single mode card.
(g0138)
Figure 5-3. Faceplate of an ATM OC-12c (version 1) single mode media card
The version 2 card faceplate has revision number G (or later) for a multimode card, or H (or later) for a single mode card.
Figure 5-4. Faceplate of an ATM OC-12c (version 2) single mode media card
LEDs
The top four LEDs indicate card status. The duplex interface has a set of LEDs. Table 5-4
describes the ATM card LEDs.
Table 5-4. ATM OC-12c LEDs
LED
Power
Fault
Description
This green LED is on when GRF power is on.
This amber LED turns on and remains on if an error condition is detected.
(g0138)
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-11
Cabling and Verifying Media Cards
ATM OC-12c media card
Table 5-4. ATM OC-12c LEDs
LED
STAT 0
STAT 1
RCV ACT
XMT ACT
LINK OK
LASER ON
Description
These green LEDs blink during self-test. When self-test completes,
STAT 0 blinks ten times a second and STAT 1 blinks once a second.
STAT 0 and STAT 1 indicate the activity of normal system interrupts. If the media card hangs, they either turn off and remain off, or they turn on and remain on.
This amber LED blinks as ATM cells are received at the interface.
This amber LED blinks as ATM cells are transmitted out of the interface.
This green LED goes on when an optic cable is plugged into an interface and remains on while connection is good at both cable ends.
This green LED provides a safety warning on single mode ATM cards.
One should not look into a laser-active interface component.
Laser safety
The ATM OC-12c single mode media card contains a Class 1 laser product. The Class 1 laser diode is an integral part of the transceiver module.
CLASS 1 LASER PRODUCT
KLASSE 1 LASER PRODUKT
(g0079)
Warning: Only authorized service personnel should attempt to repair this equipment. All problem discovery and repair procedures are detailed to allow only subassembly/module level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.
Warnung : Lebenensgefahr Achtung, nur authorisiertes Kundendiestpersonal darf dieses
Geraet reparieren. Alle Fehler- und Reparaturvorschriften sehen nur den Austausch von
Baugruppen oder Module vor. Wegen der Komplexitaet der einzelnen Platinen und
Baugruppen soll niemand versuchen Reparaturen auf der Bauteilebene oder Modifikationen an den Platinen vorzunehmen. Falsche Reparaturen koennen lebensgefaehrlich sein.
5-12 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
ATM OC-12c media card
Table 5-5 provides technical information about the laser diode on the ATM OC-12c single
mode media card:
Table 5-5. ATM OC-12c csingle mode laser information
Manufacturer
Part number
Laser type
Wave length
Output power
Agency approvals
Hewlett Packard
CDX2622
Fabry Perot
1274 nm minimum, 1356 nm maximum
Single-mode, -15dBm min., -8dBm max
Multi-mode, -20dBm min., -14dBm max
TUV Rheinland - EN 60950
- EN 60825-1
- EN 60825-2
Complies with 21 CFR 1040.10 and 1040.11
Attaching ATM media cables
GRF ATM media cards are available in both multimode and single mode.
A multimode card requires duplex SC fiber optic cable and has a distance limitation of approximately two kilometers. A single mode card requires simplex SC fiber optic cable and
has a distance limitation of approximately 15 kilometers. Figure 5-5 shows both types of
cables.
Excess cable lengths should be bound in a figure-eight pattern. Do not wind excess cable into circular coils.
Multimode pair
Single mode pair
Dust caps
Figure 5-5. Single and multi-mode ATM cable ends
Not only are fiber cables easier to damage than coax and other types of cables, but the damage is harder to detect.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-13
Cabling and Verifying Media Cards
ATM OC-12c media card
Keep cables off the floor
Cables left on the floor can get damaged. The resulting broken fiber might work fine temporarily but begin to cause problems when the cable is moved or bent the other way.
Keep the connectors clean
A broken cable or dirty connector can deliver data, but with errors. Attaching a dirty connector can soil the optical component on the media card. Leave the dust caps on until you are ready to insert the cable ends.
!
Caution: Although there may be no hazard with multimode fiber, it is not a wise practice to look into the end of any fiber optic cable.
Vorsicht: Obwohl Multimodenfasern voraussichtlich keine Gefahr darstellen, empfiehlt es sich, nicht in das Ende eines Glasfaserkabels hineinzuschauen.
5-14 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
FDDI/Q media cards
FDDI/Q media cards
The FDDI/Q media card provides four full-duplex interfaces. Figure 5-6 shows a FDDI/Q
faceplate.
T A T
A 0 B 0 A 1 B 1
(g0005)
Figure 5-6. FDDI/Q media card faceplate
LEDs
STAT 0 and 1
Each interface has a pair of LEDs that show the type of connection (OP) and traffic activity
(TRX) at that interface. Refer to Figure 5-7.
OP for A0 TRX for A0 External optical bypass connection site
OP for A1
T A T A 0 B 0 A 1 B 1
Figure 5-7. FDDI/Q media card faceplate and LEDs
Certain LEDs on the FDDI/Q media card can be either amber or green depending upon the
type of information they convey at the time. Table 5-6 describes FDDI/Q card LEDs.
Table 5-6. FDDI/Q media card LEDs
LED
PWR ON
STAT 0
STAT 1
Description
This green LED is on when GRF power is on.
The amber / green Status LEDs at the top of each FDDI/Q media card are amber during self-test. When self test completes, the LEDs turn green.
The Status LEDs alternate amber during power-on/dumping, and alternate green during power-on/loading.
When status is normal:
- the green 0 LED on the left blinks ten times a second
- the green 1 LED on the right blinks once a second
FDDI/Q Status LEDs do not blink error codes.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-15
Cabling and Verifying Media Cards
FDDI/Q media cards
Table 5-6. FDDI/Q media card LEDs (continued)
LED
OP0, OP1,
OP2, OP3
TRX
Description
The amber / green OP LEDs indicate the type of ring connection made at the particular interface:
When OP is off, no viable connection is enabled.
When OP is green, a SAS connection is configured.
When OP is amber, a DAS connection is configured.
These green LEDs blink when FDDI/Q traffic is active in either direction at a particular interface (updated each 100 ms).
Attaching FDDI/Q media cables
Not only are fiber cables easier to damage than coax and other types of cables, but the damage is harder to detect.
Excess cable lengths should be bound in a figure-eight pattern. Do not wind excess cable into circular coils.
Keep cables off the floor
Cables left on the floor can get damaged. The resulting broken fiber might work temporarily, but begin to cause problems when the cable is moved or bent the other way.
Keep the connectors clean
A broken cable or dirty connector can still deliver data, but with errors. Attaching a dirty connector can soil the optical component on the media card.
Leave the dust caps on until you are ready to insert the cable ends.
!
Caution: Although there may be no hazard with multimode fiber, it is not a wise practice to look into the end of any fiber optic cable.
Vorsicht: Obwohl Multimodenfasern voraussichtlich keine Gefahr darstellen, empfiehlt es sich, nicht in das Ende eines Glasfaserkabels hineinzuschauen.
5-16 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
FDDI/Q media cards
FDDI connector keys
Connector keys are small plastic fittings that physically prevent the wrong type of FDDI connector from being inserted into a media card interface. Lucent ships a set of keys with each
FDDI media card. Figure 5-8 shows a set of “B” keys installed on a FDDI connector and a set
of “A” keys as they are shipped with a FDDI card.
FDDI multimode connector end
B
“A” connector key set
“B” connector key
Figure 5-8. FDDI optic cable connector and keys
A set of keys physically installs in both the card interface and the cable connector. Installing keys in FDDI media card interfaces is easy even though installation requires removing the
FDDI media card from the chassis. The key “snaps” into a slot within the interface.
Different cables are required for single and dual attached interfaces. Dual attach FDDI cables have an “A” connector on one end and a “B” connector on the other. Single attach FDDI cables have an “M” connector on one end and an “S” connector on the other. Connector keys are site-installed according to site practice. Not every site uses them.
It is not necessary that connector keys be used. The GRF FDDI card already has “A” and “B” labels on its faceplate that provide visual “keys” for dual attachments. As a single attachment, the interface accepts both master and slave cable connectors without affecting configuration.
Connector key types
Once installed, a key limits the type of FDDI cable that can be inserted into that interface.
Different cables are matched to single and dual attached interfaces. Cables and interface ports are labeled or “keyed” so they will connect only to a compatible interface type.
Figure 5-9 illustrates different types of receptacle and connector keys:
Receptacle keying Connector keying
Key type “AM”:
Key type “A”:
Key type “B”:
Key type “M”:
Key type “S”:
Figure 5-9. Types of FDDI connector keys
Key type “BM”:
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-17
Cabling and Verifying Media Cards
FDDI attachment options
FDDI attachment options
Attachment summary
A variety of attachment options are supported on GRF FDDI cards. Figure 5-10 summarizes
all possible options:
4 single attach:
A0
FDDI
B0
A1
B1
1
1
1
1
2 dual attach:
A0
FDDI
B0
A1
B1
1 dual, 2 single
(or unused) attach:
A0
FDDI
B0
A1
B1
2 single (or unused),
1 dual attach:
A0
FDDI
B0
A1
B1
Figure 5-10. DAS and SAS connection options
Refer to the GRF Configuration and Management manual for FDDI configuration information and copies of configuration files.
SAS and DAS attachments
Single attach station (SAS) refers to a device connected to FDDI media via a single connector.
In comparison, a dual attach station (DAS) device has independent connections to each of two
FDDI rings, for redundancy. Figure 5-11 shows an example of each type of attachment.
Two dual attachments: Four single attachments:
• • •
IFDDI
Controllers
IFDDI
Controllers
FDDI Ring 1
Workstation
Workstation
Concentrator
FDDI Ring 2
SAS
SAS
SAS
Server
Figure 5-11. FDDI media cards used as single and dual attachment nodes
5-18 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
FDDI attachment options
Single attach - M and S interfaces
Single attach FDDI interfaces can be either master (M) or slave (S) interfaces.
They require a cable with a corresponding master or slave connector. Single attach cables have an “M” connector at one end and an “S” connector on the other. With no key installed, “M” and
“S” connectors both fit the FDDI interface.
Figure 5-12 show the relationship between master and slave interfaces.
Single attach:
A0
FDDI
B0
A1
B1
M M
S S
S S
M M
FDDI
Concentrator
M M
M M
M M
S S
S S
S S
Figure 5-12. Single attach FDDI interface using master / slave keys
A single attach FDDI interface on the GRF is a master interface when it directly connects to a workstation. It is a slave interface when connected to the master interface of a FDDI concentrator. Such concentrators connect, in turn, to the slave interfaces of single-attach workstations.
Dual attach - A and B interfaces
Dual attach interfaces connect to form two unbroken counter-rotating rings, one being a redundant backup. Each interface, or station, has both an “A” and a “B” interface. Dual attach cables have an “A” connector on one end and a “B” connector on the other.
The “A” interface connects a station to its downstream neighbor; the “B” interface connects a station to its upstream neighbor. To create a logical ring, “A” must connect to “B”, “B” must connect to “A”. Otherwise, the network does not operate as a logical ring and segments into
unconnected suborns. Figure 5-13 illustrates a logical ring.
Dual attach:
A0
FDDI
B0
A1
B1
B B
Station
1
A A
A A
B B
A A
Station
N...
B B
B B
Station
2
A A
Logical ring
. . . A A
Station
3
B B
Figure 5-13. Dual attach FDDI interface using A / B keys
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-19
Cabling and Verifying Media Cards
Installing a FDDI optical bypass
Installing a FDDI optical bypass
Optical bypass capability is provided externally to the FDDI media card.
A miniature six-pin DIN connector is provided on the FDDI face plate for controlling two external optical bypass switches, one for each dual attachment transceiver pair.
An external converter cable is required to split out two optical bypass connectors from the single face plate connector. Control and status bits for the optical bypass switches are provided in the main processor's status and control registers.
As shown in Figure 5-14, two bypass switches can be attached with the Lucent-supplied
Y-cable adapter. The Y-cable is required to reconcile control pin assignments between the GRF and the external switch module.
Through the Y-cable, an optical bypass switch module attaches to a pair of media interface connectors on the FDDI card.
FDDI
Media Card
Switch Module
Ring 1
FDDI
Media Card
Switch Module 1
Ring 1
Switch Module 2
Ring 2
Figure 5-14. Optical bypass switch attachments
A bypass switch allows the GRF to remove itself from the dual ring during a failure or maintenance without causing the ring to wrap at upstream and downstream neighbors. If a
GRF failure occurs, the bypass switch connects upstream and downstream neighbors on both the primary and secondary rings, and allows the GRF node to remove itself from the ring while still retaining ring continuity.
A node failure without a bypass switch causes the dual ring to “wrap.” A wrapped ring absorbs the secondary ring into the primary ring and no longer has a backup ring.
Manual enable/disable
With the bypass physically installed, you can enable or disable the function in the Card profile for the specific FDDI card. Refer to the FDDI configuration chapter in the GRF Configuration
and Management manual.
5-20 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
HIPPI media card
HIPPI media card
The HIPPI media card provides a single full-duplex interface. Figure 5-15 shows a HIPPI
faceplate.
(g0006)
Figure 5-15. HIPPI media card faceplate
Attaching HIPPI media cables
The HIPPI media card provides a single duplex attachment and requires a pair of copper cables/connector ends as described in the standard HIPPI-PH, ANSI x3.183-1991.
Excess cable lengths should be bound in a figure-eight pattern. Do not wind excess cable into circular coils. HIPPI cables are specified in the standard to a length of 25 meters. Lucent certifies the viability of GRF-to-GRF connections using cables 51 meters long.
As shown in Figure 5-16, the upper HIPPI interface (RCV or destination interface) receives
data from the host. The lower interface (XMT or source interface) transmits data to a host.
HIPPI media card
Input from host: DST (destination)
Output to host: SRC (source)
Figure 5-16. Cabling a HIPPI media card
Do not damage the connector ends
Each connector end has 100 fragile pins. Figure 5-17 illustrates a HIPPI cable connector end.
Pins can become bent while making the connection to the media card if alignment is wrong. If a HIPPI link does not work after cabling, check both ends of the cable for bent pins.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-21
Cabling and Verifying Media Cards
HIPPI media card
HIPPI 100-pin connector end
Figure 5-17. HIPPI 100-pin connector
Keep the bubble wrap on
Lucent ships cables with the connector ends enclosed in bubble wrap. Keep this bubble wrap on while you lay out the cabling. Remove the bubble wrap when you are ready to plug in the connector.
Warning: A connector can build up enough charge to disable the media card.
One way to discharge a cable is to run your finger gently over the tips of the pins, touching pins and the connector shell at the same time.
Warnung : Es kann sich genug Ladung in einem Stecker ansammeln, daß die
Datenträgerkarte deaktiviert wird. So wird das Kabel entladen: Fahren Sie mit dem Finger vorsichtig über die Spitzen der Stifte; berühren Sie dabei gleichzeitig die Stifte und das
Steckergehäuse.
Insert the connector perpendicular to the media card
The EMI shielding fitted inside the connector end can make insertion difficult. Insert the connector end very nearly perpendicular. Pins can be damaged when the connector is inserted at too much of an angle.
Tighten the jackscrews all the way down
Connector ends are heavy and tend to resist being completely seated. Tighten the jackscrews to make a firm attachment. Jackscrews should turn easily and stop abruptly when they hit bottom.
If the connector is not fully seated, it may not operate properly.
5-22 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
HIPPI media card
HIPPI card LEDs
The HIPPI media card has one receive (from destination) interface and one transmit (to source) interface. The upper interface, A, is the RCV or destination interface. The lower interface, B, is
the SRC or source interface. Figure 5-18 shows the set of eight LEDs at the top of the
faceplate.
All 4 are green when card is ready
D E S T I N A T I O N
S O U R C E
Local
Remote
Figure 5-18. HIPPI media card faceplate and LEDs
Refer to Table 5-7 for a description of HIPPI card LEDs.
Table 5-7. HIPPI media card LEDs
LED
Description
Power
Status
DST ENA
(local)
SRC ENA
(local)
DST ENA
(remote)
SRC ENA
(remote)
RX ACT
TX ACT
This green LED is on when GRF power is on.
When self-test completes, this green LED turns on and remains steadily on during normal operations. The Status LED blinks when an error condition is detected.
This green LED is on when the input destination interface is asserting the interconnect signal and is ready for operation.
This green LED is on when the output source interface is asserting the interconnect signal and is ready for operation.
HIPPI directly connects to a HIPPI host or to a network device.
This green LED is on when the remote destination interface is asserting the interconnect signal and is ready for operation.
HIPPI directly connects to a HIPPI host or to a network device.
This green LED is on when the remote source interface is asserting the interconnect signal and is ready for operation.
This green LED indicates data is being received at the input interface, the blink rate depends on the traffic load.
This green LED indicates data is being sent from at the output interface, the blink rate depends on the traffic load.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-23
Cabling and Verifying Media Cards
HSSI media card
HSSI media card
A HSSI media card provides two full-duplex interfaces. Figure 5-19 shows a HSSI faceplate.
(g0007)
Figure 5-19. HSSI media card faceplate
Attaching HSSI media cables
The GRF HSSI media card provides two full-duplex attachments and requires a pair of copper cables/connector ends as described in the HSSI High Speed Serial Interface Design
Specification (March 1990). Figure 5-20 illustrates a HSSI cable connector.
HSSI cables are specified to a length of 15 meters (50 feet). Excess cable lengths should be bound in a figure-eight pattern. Do not wind excess cable into circular coils.
HSSI 50-pin connector end
5-24 October, 1998
Figure 5-20. HSSI 50-pin connector end
Do not damage the connector ends
Each connector end has 50 fragile pins. Pins can become bent while making the connection to the media card if alignment is wrong. If a HSSI link does not work, check both ends of the cable for bent pins.
Warning: A connector can build up enough charge to disable the media card.
One way to discharge a cable is to run your finger gently over the tips of the pins, touching pins and the connector shell at the same time.
Warnung : Es kann sich genug Ladung in einem Stecker ansammeln, daß die
Datenträgerkarte deaktiviert wird. So wird das Kabel entladen: Fahren Sie mit dem Finger vorsichtig über die Spitzen der Stifte; berühren Sie dabei gleichzeitig die Stifte und das
Steckergehäuse.
Insert the connector perpendicular to the media card
The EMI shielding fitted inside the connector end can make insertion difficult. Insert the connector end very nearly perpendicular. Pins can be damaged when the connector is inserted at too much of an angle. Seat the connector firmly so the spring clips are engaged.
GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
HSSI media card
Problems with bad HSSI cables
Messages similar to the following may show up in the gr.conslog
log if a HSSI cable is bad:
# grconslog -pf
[6] [RX] Received with errors. Desc: 0x642C8002
[6] [RX] (Abort.)
[6] [RX] Received with errors. Desc: 0x642CC002
[6] [RX] (Abort.)
[6] [RX] Received with errors. Desc: 0x642D0002
[6] [RX] (Abort.)
[6] [RX] Received with errors. Desc: 0x642D4002
[6] [RX] (Abort.)
HSSI card LEDs
Figure 5-21 shows the HSSI faceplate and LEDs. At the top of the HSSI face plate are five
LEDs that indicate card status. Each HSSI interface has two sets of LEDs that indicate link and packet information. Each interface has a connector for attaching an encryption modem.
RCV CPU
(CPU0)
XMT CPU
(CPU1)
Connection
/ link status
Packet activity
Connector for encryption modem
Figure 5-21. HSSI media card faceplate and LEDs
Refer to Table 5-8 for a description of HSSI card LEDs.
Table 5-8. HSSI media card LEDs
LED Description
Power
Fault
STAT 0
STAT 1
STAT 2
RCV / XMT
Status
RCV / XMT
Active
This green LED is on when GRF power is on.
This amber LED turns on and remains on if an error condition is detected.
The Fault and STAT 0 LEDs alternate during self-test and while the HSSI card is loading. If the HSSI card is dumping, these two flash in unison.
During normal running time, these green LEDs blink together in a heartbeat pattern, one for each CPU on the card.
This green LED is inactive during normal running time.
These green LEDs indicate the status or viability of the HSSI connection for interface A or interface B.
These green LEDs indicate the frequency of packet traffic across an interface.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-25
Cabling and Verifying Media Cards
Ethernet media cards
Ethernet media cards
The 8-port Ethernet media card provides eight full-duplex interfaces. Figure 5-22 shows an
8-port faceplate.
(g0003)
Figure 5-22. Ethernet 8-port media card faceplate
The 4-port Ethernet medis card provides four full-duplex interfaces. Figure 5-23 shows a
4-port faceplate.
(g0141)
Figure 5-23. Ethernet 4-port media card faceplate
Attaching 10/100Base-T media cables
There are two types of Ethernet 10/100Base-T media cards, one provides four physical interfaces, one provides eight physical interfaces. The cards run the same code, have the same
LEDs, and are otherwise the same. Each physical interface is capable of full and half-duplex operation, and can run at either 100 Mb/s or 10 Mb/s rates.
Ethernet cables are specified to a length of 100 meters.
As shown in Figure 5-24, the Ethernet interface requires RJ-45 connectors and Category 5
UTP cables.
RJ-45 connector
Figure 5-24. Cable connector for a 10/100Base-T interface.
5-26 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
Ethernet media cards
Ethernet card LEDs
Status
Each Ethernet port has a set of four LEDs that describe the presence of a link and its type, the type of duplex or collision interface implemented, and port transfer activity.
An 8-port Ethernet faceplate and LEDs are shown in Figure 5-25.
Receive data Link type Sending data Duplex / collision condition
Figure 5-25. Ethernet media card faceplate and LEDs
LEDs for both types of Ethernet cards are described in Table 5-9.
Table 5-9. Ethernet media card LEDs
LED
PWR
STAT
100
COL
RXD
TXD
Description
This green LED is on when GRF power is on.
During normal operations, this LED is green.
If an error condition is detected, this LED turns amber and remains on.
This LED is green for a 10 megabit link.
This LED is amber for a 100 megabit link.
This LED remains off (dark) when there is no viable link.
This LED reads black (dark) for a half-duplex interface.
This LED is amber for a half-duplex interface when encountering a transmission collision condition.
This LED is green for a full-duplex interface.
This green LED indicates this port is receiving data.
This green LED indicates this port is transmitting data.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-27
Cabling and Verifying Media Cards
SONET OC-3c media card
SONET OC-3c media card
The SONET OC-3c media card provides a single redundant full-duplex interface and has hardware-enhanced route table lookup. The SONET card is available in single and multimode
versions. Figure 5-26 shows a SONET OC-3c faceplate.
The SONET card provides redundant link connections across two physical interfaces. Only one logical interface is supported. By default, the upper link (A) is active. Use this interface if you are not setting up redundant links. If the active link is terminated, the redundant interface automatically becomes active.
(g0137)
Figure 5-26. SONET OC-3c single mode media card faceplate
Laser safety
The SONET OC-3c single mode media cards contain a Class 1 laser product. The Class 1 laser diode is an integral part of the transceiver module.
CLASS 1 LASER PRODUCT
KLASSE 1 LASER PRODUKT
(g0079)
Warning: Only authorized service personnel should attempt to repair this equipment. All problem discovery and repair procedures are detailed to allow only subassembly/module level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.
Warnung : Lebenensgefahr Achtung, nur authorisiertes Kundendiestpersonal darf dieses
Geraet reparieren. Alle Fehler- und Reparaturvorschriften sehen nur den Austausch von
Baugruppen oder Module vor. Wegen der Komplexitaet der einzelnen Platinen und
Baugruppen soll niemand versuchen Reparaturen auf der Bauteilebene oder Modifikationen an den Platinen vorzunehmen. Falsche Reparaturen koennen lebensgefaehrlich sein.
5-28 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
SONET OC-3c media card
Table 5-10 provides technical information about the laser diode on the SONET OC-3c single
mode media card:
Table 5-10.SONET OC-3c single mode laser information
Manufacturer
Part number
Laser type
Wave length
Output power
Agency approvals
Amp Inc.
269085-1
InGaAsP diode
1310 nm (+/- 50 nm)
-14dBm min., -8dBm max
TUV Rheinland
- EN 60950
- EN 60825-1
- EN 60825-2
Complies with 21 CFR 1040.10 and 1040.11
Attaching SONET media cables
GRF SONET OC-3c media cards are available in both multimode and single mode.
A multimode card requires duplex SC fiber optic cable and has a distance limitation of approximately two kilometers. A single mode card requires simplex SC fiber optic cable and
has a distance limitation of approximately 15 kilometers. Figure 5-27 shows both types of
cables. Excess cable lengths should be bound in a figure-eight pattern. Do not wind excess cable into circular coils. Not only are fiber cables easier to damage than coax and other types of cables, but the damage is harder to detect.
Single mode pair
Multimode pair
Dust caps
Figure 5-27. Single and multi-mode SONET cable ends
Keep cables off the floor
Cables left on the floor can get damaged. The resulting broken fiber might work fine temporarily but begin to cause problems when the cable is moved or bent the other way.
Keep the connectors clean
A broken cable or dirty connector can deliver data, but with errors. Attaching a dirty connector can soil the optical component on the media card. Leave the dust caps on until you are ready to insert the cable ends.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-29
Cabling and Verifying Media Cards
SONET OC-3c media card
!
Caution: Although there may be no hazard with multimode fiber, it is not a wise practice to look into the end of any fiber optic cable.
Vorsicht: Obwohl Multimodenfasern voraussichtlich keine Gefahr darstellen, empfiehlt es sich, nicht in das Ende eines Glasfaserkabels hineinzuschauen.
SONET card LEDs
The top four LEDs indicate card status. The SONET media card has two duplex interfaces,
A and B, and each interface has its own set of three LEDs. Refer to Figure 5-28.
Link OK for A (default active interface) Link OK for B
(g0140)
Figure 5-28. SONET OC-3c single mode media card faceplate and LEDs
Table 5-11 describes the SONET card LEDs.
Table 5-11.SONET OC-3c LEDs
LED
Power
Fault
STAT 0
STAT 1
RCV ACT
XMIT ACT
LINK OK
LASER ON
Description
This green LED is on when GRF power is on.
This amber LED turns on and remains on if an error condition is detected.
These green LEDs blink during self-test. When self-test completes,
STAT 0 blinks ten times a second and STAT 1 blinks once a second.
STAT 0 and STAT 1 indicate the activity of normal system interrupts. If the media card hangs, they either turn off and remain off, or they turn on and remain on.
This amber LED blinks as data is received at the interface.
This amber LED blinks as data is transmitted out of the interface.
This green LED is on steadily to indicate which of the interfaces is active. The LED for the non-active interface blinks on and off.
This green LED provides a safety warning on single mode SONET cards. One should not look into a laser-active interface component if a cable is not plugged in.
5-30 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
Media card reset and checkout
Media card reset and checkout
This section describes tools available from the system software to check out newly-installed media cards. These tools are to be used on the GRF router
• The ping command tests whether a media card can process and return a message.
• The grcard command tells you the operating state of an installed media card.
• The grreset command allows you to reset all or an individual media card.
Verify media card operation using ping
Check media card viability using the ping command. This UNIX command is modified to support GRF board components. This use of ping only tests internal communication between the GRF control board and the specified media card. It does not test message routing between media cards or communication between media cards and external devices.
Note: The ping command can be used without disturbing normal GRF operations.
The ping -P grid <slot number> command sends a message to a specified media card asking the media card to respond back with another message.
1 Log in as root .
2 Enter a ping command. Specify the appropriate media card by its chassis slot number.
For example, to act on the media card in slot 3, enter:
# ping -P grid 3
This is what you see when the media card responds:
68 bytes from 0:0x3:0: time=0.293 ms
68 bytes from 0:0x3:0: time=0.251 ms
68 bytes from 0:0x3:0: time=0.288 ms
•
•
•
Do a Control+C to stop the ping and view ping statistics:
-- 2 GRID ECHO Statistics --
2 packets transmitted, 2 packets received, 0% packet loss round-trip min/avg/max = 0.969/1.060/1.172 ms
To act on the control board, enter:
# ping -P grid 66
Refer to the GRF Reference Guide for a description of the ping command.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-31
Cabling and Verifying Media Cards
Media card reset and checkout
Check media card status using grcard
The grcard command returns information about the status of all installed media cards.
Enter:
# grcard -v
Here is a sample of the slot, media, and state information returned from the grcard command:
# grcard -v
Slot HWtype State
0 HSSI_V1 running
1 ATM_OC3_V1 running
2 FDDI_V1 running
3 FDDI_V2 running
Refer to the command descriptions in the GRF Reference Guide for a description of grcard
Media card states
The following states are reported:
POWER-UP
BOOT-REQUESTED
DUMPING
LOADING
CONFIGURING
RUNNING
NOT-RESPONDING
PANIC
HELD-RESET
STATE UNKNOWN
- initial state of a card at system power on
- card has requested its run-time code
- card is being dumped
- card is receiving run-time code
- card has requested its configuration tables
- card is configured and operating
- card does not respond to requests from the management software
- card has encountered a system fault
- card is being held in reset state
- state cannot be determined
The Power-up state is the normal condition as power is being applied to the media card.
The Boot-requested state is one step in the progress of a card during initial power-up, while a card is coming up, or while a card is being reset due to user or software direction.
Dumping is the resulting state when a card is directed to dump at reset, at a panic, or as user-specified in the Dump or Card profile.
Loading is a state during which the card receives its run-time image.
Configuring is a waiting state for the media card after it issues a request for configuration parameters. The card stays in the configuring state after being loaded until it has all necessary configuration information, is initialized, and the kernel recognizes that the card is up.
Running is the normal operating state, the card is able to receive and send packets.
Not-responding is a state in which the card does not answer requests from the operating software. The card could be hung. If it decides a card is hung, the kernel begins an automatic reset.
5-32 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
Media card reset and checkout
A system fault can cause a card to go into the Panic state. After a card panics, it needs operator or kernel intervention to start up. The kernel either reboots the card, or dumps and then reboots, depending upon how variables are set in the Dump or Card profile.
An operator can use the grreset -h command to put a card into the Held_reset state to keep it up but not transferring packets.
When the kernel cannot determine what a media card is doing, it places the card into State unknown, and either reboots the card, or dumps and then reboots the card, depending upon how variables are set in the Dump or Card profile.
Reset media card using grreset
Use the grreset command to reset a media card from the UNIX prompt.
1 Log in as root .
2 Enter the grreset command.
Specify the appropriate media card by its chassis slot number.
To reset all the media cards, enter:
# grreset all
To reset the media cards in slots 0 and 1, enter:
# grreset 0 1
To reset the card in slot 4 and dump its memory, enter:
# grreset -D 4
To reset the card in slot 4 and return debug information, enter:
# grreset -d 4
Note: The grreset command can be used on a media card without disturbing normal GRF system operations.
Refer to the command descriptions in the GRF Configuration and Management manual for a description of grreset
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-33
Cabling and Verifying Media Cards
Rebooting the system
Rebooting the system
You shut down the system depending upon how you connect to the GRF. When you are using the VT 100 terminal (or laptop), use the grms command. When you are have logged into the
GRF from a remote workstation on the administrative Ethernet, use the shutdown command.
Rebooting from the VT 100 terminal - grms
Use the grms command to halt, reboot, or shut down the system from the UNIX prompt.
grms performs the same function as shutdown but does not require the user to be logged in as root . However, it can only be used from the control board VT-100 terminal. Use shutdown -r
now if you manage the GRF from a remote terminal.
The grms command performs an orderly shutdown, saving memory and allowing any transfers to complete. When the reboot option is specified, the system is rebooted and all media cards are reset.
1 Attach a keyboard to the VT-100 terminal and log in. You do not have to be root .
2 Enter the grms command with one of its options:
With the -h option, grms halts the system (like shutdown -h now).
With the -r option, grms performs an orderly reboot of the system (like shutdown -r now).
With the -s option, grms performs an orderly shutdown of the system. To restart, enter the
reboot command.
Rebooting from a remote workstation - shutdown
If you manage the GRF from a remote station, use the shutdown command to reset the system from a UNIX prompt.
The shutdown command performs an orderly shutdown, saving memory and allowing any transfers to complete. With the -r and now options, the command performs an orderly reset of the system. It also issues a special command to the control board to restart the GRF immediately.
1 Log in as root .
2 Enter the shutdown -r now command.
After the shutdown completes, the prompt appears and you can log in again.
5-34 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
Running media card hardware diagnostics
Running media card hardware diagnostics
You can run a basic diagnostic command that will tell you if a media card has a hardware problem. The grdiag command performs internal BIST-level diagnostics. A media card that fails this grdiag must be replaced and returned to Lucent. You can run grdiag on one or more cards without interrupting other media cards or system operation. Only HIPPI media cards do not support the grdiag command
The grdiag script puts the selected media card(s) into diagnostic mode and runs the diagnostics. After the diagnostics complete, grdiag reloads the media card’s software and configuration currently saved in flash memory, then reboots the card. For this reason, it is very important that you save any configuration changes before you run grdiag. Unsaved media card changes will be lost.
For grdiag to run, a card must be able to boot. If the grcard display does not include the slot in which the problem card resides, grdiag cannot operate on that card.
More information is available in the “Management Tools” chapter of the GRF Configuration
and Management manual.
Special login
Do not log in directly as root to use the grdiag command. To use grdiag, you must log in as a user and then su to root .
This example uses the netstar login (password = Ascend ) that a GRF is shipped with:
User: netstar
Password: ...... erase ^H, kill ^U, intr ^C status ^T
$
If you changed the default password as recommended, use the new password.
At the next prompt, enter su and use the root password at the prompt. You will see the UNIX prompt appear:
$ su
Password:
#
Now you can run grdiag.
Running grdiag
The grdiag command starts a script. The script is simple to run. Here are the choices you make:
– choose to save unsaved changes – y / n ?
– enter slot number(s) of media card(s) to test
Enter the grdiag command:
# grdiag
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-35
Cabling and Verifying Media Cards
Running media card hardware diagnostics
Portcard Field Diagnostic
#################################################################
# WARNING: Make sure your current Configuration is Saved to FLASH!!
#
#################################################################
If Not Would you Like to Save it Now y/n? [y]:
You see this warning whether or not there are unsaved configuration changes. If you enter yes, save changes, the activity on internal flash is reported back:
If Not Would you Like to Save it Now y/n? [y]: y
Device /dev/wd0a mounted on /flash.
Device /dev/wd0a unmounted.
If you enter No and you do have unsaved changes, the last-saved configuration will be reloaded after the diagnostic sequence runs. A reply is not made to a No entry.
The first grdiag display is an inventory of the current media card status
“N/A” indicates that these diagnostics do not run on the HIPPI card):
------------------------------------------------------------------
- Media Card Inventory
-
------------------------------------------------------------------
Slot Card Type Card Status Test Status
---- ---------------- ------------- ------------
0 atm-oc3-v2 running
1 atm-oc3-v2 running
2 hssi running
3 hippi-v1 running N/A
After the inventory display, you enter the slot numbers of the card(s) you want to test:
Enter the media card slot numbers to test
Use "all" or a space separated list (0 1 2 etc.): 1 2
The list of cards queued to be tested is displayed:
------------------------------------------------------------------
- Cards Queued for Test
-
------------------------------------------------------------------
Slot Card Type Card Status Test Status
---- ---------------- ------------- ------------
0 atm-oc3-v2 running
1 atm-oc3-v2 running Queued
2 hssi running Queued
3 hippi-v1 running N/A
Are you absolutely sure you want to proceed? y/n? [No]:
After the queue list is displayed, you are asked to verify that you want to start the diagnostic, the default is No. If you answer No, you are given a chance to change the parameters you have
5-36 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
Running media card hardware diagnostics already specified. If you answer No again to changing parameters, the grdiag script ends and you are back at the shell prompt.
Are you absolutely sure you want to proceed? y/n? [No]: n
Re-enter test parameters? y/n? [No]: n
#
If you enter Yes, continue with the diagnostic, grdiag automatically accesses the CLI and reads the target card(s) Card profile(s).
Activity during testing
grdiag saves the card’s last-saved configuration to a file, and then changes Card profile load parameters so that the diagnostic code is loaded and run as you specified. The new settings are saved just as they are when you change parameter settings.
You may see some of this activity on the screen, most of it speeds by too quickly to read.
During the test you see grdiag reports that show loading and testing events:
*****************************************************************
* Waiting 114 sec. for Queued Cards to Load
*
*****************************************************************
Slot Card Type Card Status Test Status
---- ---------------- ------------- ------------
0 atm-oc3-v2 running
1 atm-oc3-v2 loading Queued
2 hssi loading Queued
3 hippi-v1 running N/A
Test started: Mon Apr 20 13:24:44 CDT 1999; Tested by: netstar
Test time: 0 hrs; 0 min; 1 sec.
*****************************************************************
* Field Diagnostic Test in Progress
*
*****************************************************************
Slot Card Type Card Status Test Status
---- ---------------- ------------- ------------
0 atm-oc3-v2 running
1 atm-oc3-v2 diagnostic Testing
2 hssi diagnostic Testing
3 hippi-v1 running N/A
The testing report is updated five or six times a minute:
Testing completes
As the diagnostics complete, grdiag again accesses the Card profiles and writes the parameters back to the original settings. A tested card is rebooted even if it failed the diagnostic. Again, the display speeds by too quickly to read:
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-37
Cabling and Verifying Media Cards
Running media card hardware diagnostics
After the cards reboot, you see the final report. This report is also sent to
/var/log/grdiag.log
:
Test time: 0 hrs; 2 min. End date: Mon Apr 20 13:27:49 CDT 1999
*****************************************************************
* Field Diagnostic Test Ended. 2 Passed 0 Failed.
*
*****************************************************************
Slot Card Type Card Status Test Status
---- ---------------- ------------- ------------
0 atm-oc3-v2 running
1 atm-oc3-v2 Idle Passed
2 hssi Idle Passed
3 hippi-v1 running N/A
Though the Card Status is reported as idle, the cards are actually up. Use grcard to verify card status:
# grcard
0 ATM_OC3_V2 running
1 ATM_OC3_V2 running
2 HSSI_V1 running
3 HIPPI_V1 running
#
If a card fails...
This is the report you see when a media card fails the diagnostic. It is the same information sent to /var/log/grdiag.log
:
Start date: Mon Apr 20 19:40:12 CDT 1999; Tested by: netstar
Test time: 0 hrs; 10 min. End date: Mon Apr 20 19:51:18 CDT 1999
*****************************************************************
* Field Diagnostic Test Ended. 3 Passed 1 Failed.
*****************************************************************
Slot Card Type Card Status Test Status
---- ---------------- ------------- ------------
0 ethernet-v1 BIST monitor Failed
1 hssi Idle Passed
2 fddi-v2 Idle Passed
3 fddi-v2 Idle Passed
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
! Possible Additional Error Information !
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Filtered contents of /var/log/gr.console:
Apr 20 19:51:05> [RMS] rmb0: Resetting Media Card 0
Apr 20 19:51:18> [1] UNEXPECTED Router Manager Interrupt
Apr 20 19:51:18> [2] UNEXPECTED Router Manager Interrupt
Apr 20 19:51:18> [3] UNEXPECTED Router Manager Interrupt
Remember that the error code is sent to the /var/log/gr.console
log.
5-38 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Cabling and Verifying Media Cards
Running media card hardware diagnostics
Error reporting
grdiag reports to /var/log/grdiag.log
and to the /var/log/gr.console
log. If you are logging remotely, check that location for grdiag reports.
Pass-fail status reports from the diagnostic tests are sent to /var/log/grdiag.log
. This is the same information that is displayed to you after grdiag completes:
# vi /var/log/grdiag.log
Start date: Mon Apr 20 19:40:12 CDT 1999; Tested by: netstar
Test time: 0 hrs; 10 min. End date: Mon Apr 20 19:51:18 CDT 1999
******************************************************************
* Field Diagnostic Test Ended. 3 Passed 1 Failed.
*
******************************************************************
Slot Card Type Card Status Test Status
---- ---------------- ------------- ------------
0 ethernet-v1 BIST monitor Failed
1 hssi Idle Passed
2 fddi-v2 Idle Passed
3 fddi-v2 Idle Passed
Event and error code reporting is done in the gr.console
log. The diagnostic start and stop events are reported:
# vi gr.console
!! Start of Diagnostic Test !!
.
.
.
!! End of Diagnostic Test !!
If a media card fails, an error code is reported to gr.console
log. The first two digits are the slot number of the failed media card. The next number is the major error descriptor, the last number is the minor descriptor. Record the error code and send it to your support staff.
In this example, the card in slot 1 has failed:
Slot Major Minor
!! End of Diagnostic Test !!
Built-In Self-Test Error Code = 01-3333-44
Stopping or halting grdiag
You can use Control+C to stop the diagnostic sequence at any time. After you enter
Control+C, grdiag reloads the card’s run-time binary and last-saved configuration, and then reboots the card.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 5-39
Cabling and Verifying Media Cards
Running media card hardware diagnostics
What to do next...
You have verified that the system and media card hardware is operating. Go to the GRF
Configuration and Management manual to learn more about using the CLI and completing media card configuration.
5-40 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF Specifications
Appendix A contains the following specifications for the GRF 400 and 1600 routers:
A
General specifications
Configuration information is stored in non-volatile memory. When the GRF is turned off, configuration data is not lost.
Note: Use a protected AC power source, or add surge protection between the power source and the GRF chassis.
Environmental requirements
Operating temperatures: 32
°
–104
°
F (0
°
–40
°
C)
Operating humidity level: 10% – 90%, non-condensing
Altitude: 0 to 10,000 feet (0 to 3048 meters)
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 A-1
GRF Specifications
GRF 400 chassis specifications
GRF 400 chassis specifications
Table A-1 lists the general characteristics of the GRF 400 chassis.
Table A-1. GRF 400 chassis characteristics
Element Value
Weight
Dimensions
Media cards
AC power supply
26.5 pounds, chassis and one power supply (11.9 kg)
5.25 in (H) x 19 in (W) x 19 in(L) (13.34 cm x 48.26 cm x 48.26 cm)
1–4 per chassis, multiple media types supported simultaneously
Card dimensions: 9 in high x 16 in long (22.9 cm x 40.6 cm)
Card weight: approximately 2 pounds each (0.9 kg)
Hot-swap capability: all media cards are hot-swappable
400W, with an option for a redundant load-sharing unit
- double-pole/neutral fusing
- weighs 6 pounds (2.7 kg)
AC receptacle Standard US 3-prong plug, 115 V grounded receptacle
(international options available)
AC cord - North America: UL listed, CSA certified, type SJT or SVT, 3-conductor,
18AWG minimum
- outside of North America: Agency-approved for the country of use, cord type H05VVF3G1.0, 3-conductor, 1.0mm
2
, rated 250V, 10A, plug type suitable for country of use.
AC voltage
DC power supply
100–240 VAC, 6.0–3.0 Amp maximum
Phase: single
Frequency: 60/50 Hz
Power usage: 400W (nominal)
400W, with an option for a redundant load-sharing unit
- weighs 6 pounds (2.7 kg)
A-2 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF Specifications
GRF 1600 chassis specifications
GRF 1600 chassis specifications
Table A-2 lists the general characteristics of the GRF 1600 chassis.
Table A-2. GRF 1600 chassis characteristics
Element Value
Weight
Dimensions
Media cards
Fan tray
AC power supply
103.5 pounds, chassis and one power supply (46.6 kg)
23.0 in (H) x 19 in (W) x 21 in (L) (58.4 cm x 48.26 cm x 53.3 cm)
1–16 per chassis, multiple media types supported simultaneously
Card dimensions: 9 in high x 16 in long (22.9 cm x 40.6 cm)
Card weight: approximately 2 pounds each (0.9 kg)
Hot-swap capability: all media cards are hot-swappable
Single 48V unit with 2 motorized impeller fans
- field replaceable module
- weighs 13 pounds (5.85 kg)
1100W, with an option for a redundant load-sharing unit
- double-pole/neutral fusing
- weighs 21 pounds (9.45 kg)
AC receptacle IEC320-C19 to NEMA 5-15P power cord
(international options available)
AC power cord
- North America: UL listed, CSA certified, type SJT or SVT, 3-conductor,
18AWG minimum
- outside of North America: Agency-approved for the country of use, cord type H05VVF3G1.0, 3-conductor, 1.0mm
2
, rated 250V, 16A, plug type suitable for country of use.
AC voltage
DC power supply
100–240 VAC, 85–264 VAC maximum
Phase: single
Frequency: 60/50 Hz
Power usage: 1100W (nominal)
1100W, with an option for a redundant load-sharing unit
- weighs 13 pounds (5.9 kg)
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 A-3
GRF Specifications
DC power requirements
DC power requirements
Power requirements for individual GRF components are as follows:
Table A-3. DC power requirement per individual components
Component Max Amps/+5.0 V
HIPPI media card
FDDI/Q media card
8.8
9.4
ATM OC-3c/Q media card 9.0
ATM OC-12c media card 9.0
HSSI media card 10.0
4-port 10/100Base-T card 5.6
8-port 10/100Base-T card 8.0
SONET OC-3c media card 10.0
GRF 400 control board
GRF 1600 control board
5.0
3.0
Max Amps/-5.2 V Watts/unit
0
0
0
0
0
0
0
0
0
0
44.0
47.0
45.0
45.0
50.0
28.0
40.0
50.0
25.0
15.0
A-4 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF Specifications
GRF 400 control board specifications
GRF 400 control board specifications
The GRF 400 control board has the following characteristics:
Table A-4. Characteristics of the GRF 400 control board
Element Value
Processor
RAM
Intel Pentium 166 MHz
128MB basic, 512MB maximum (upgrade in 64MB SIMM increments) (8 SIMM sockets for 64MB SIMMs)
Flash memory, internal 85MB ATA flask device
Serial adapter 1 UART
100/10Base-T connector 1 autosensing, connects to PCI local bus
Temperature sensor Senses system warning and shutdown temps, enables actual IC temperature to be read, reported on by temp command
Ethernet address PROM System IP address memory (32 bytes)
Switch component 16 Gb TriQuint component
PCMCIA host adapter 2, one 85- or 175MB ATA flash device can be installed,
PCMCIA modem card is another option
GRF 1600 control board specifications
The GRF 1600 control board has the following characteristics:
Table A-5. Characteristics of the GRF 1600 control board
Element Value
Processor
RAM
Intel Pentium 166 MHz
128MB basic, 512MB maximum (upgrade in 64MB SIMM increments) (8 SIMM sockets for 64MB SIMMs)
Flash memory, internal 85MB ATA flask device
Serial adapter 1 UART
100/10Base-T connector 1 autosensing, connects to PCI local bus
Temperature sensor Senses system warning and shutdown temps, enables actual IC temperature to be read, reported on by temp command
Ethernet address PROM System IP address memory (32 bytes)
PCMCIA host adapter 2, one 85- or 175MB ATA flash device can be installed,
PCMCIA modem card is another option
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 A-5
GRF Specifications
Cable types
Cable types
GRF media cards use the following industry-standard cables:
Table A-6. Media card cable specifications
Cables/Card Description
HSSI
ATM OC-3c multimode
ATM OC-3c single mode
ATM OC-12c multimode
ATM OC-12c single mode
4-port 10/100Base-T
8-port 10/100Base-T
SONET OC-3c multimode
25 twisted-pair shielded coax cables
62.5/125 micron fiber optic cables
9/125 micron fiber optic cables
62.5/125 micron fiber optic cables
9/125 micron fiber optic cables
Category 5 UTP cables
Category 5 UTP cables
62.5/125 micron fiber optic cables
SONET OC-3c single mode 9/125 micron fiber optic cables
FDDI multimode 62.5/125 micron fiber optic cables
HIPPI Twisted-pair copper cables in 5-, 25-, or 51-meter lengths.
Lucent certifies the viability of GRF-to-GRF connections using 51-meter cables and sells HIPPI cables directly.
A-6 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF Specifications
Media card specifications
Media card specifications
FDDI specifications
The FDDI media card has the following characteristics:
Table A-7. FDDI media card specifications
Element Value
Interfaces per card Four bi-directional interfaces, multimode
All has unique IP and MAC addresses, are configurable as:
- two dual-attach interfaces
- one dual-attach interface and two single-attach interfaces
- four single-attach interfaces
100 Mbps
40-MHz transmit processor, 40-MHz receive processor
Media transfer rate
Processors
Data buffers
Route table support
4 MB input, 4 MB output
150K entries, with hardware-assisted route table lookup
Max transmission unit 4352 bytes
Connectors MIC tranceivers
Connector requirements Must meet ANSI X3.166 standards
Cables Multi-mode cables: 62.5/125micron optical fibre
Optic components Internally-produced 1,300 nm surface-emitting LEDs and photodiodes
Optical output 19 dBm minimum, 14 dBm minimum (avg.) (62.5/125 um)
Optical input sensitivity 33.5 dBm minimum, 14 dBm maximum
Optical wavelength
Spectral width
1,270 nm minimum, 1,330 nm typical, 1,380 nm maximum
130 nm maximum
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 A-7
GRF Specifications
Media card specifications
ATM OC-3c specifications
The ATM OC-3c media card has the following characteristics:
Table A-8. ATM OC-3c media card specifications
Element Value
Interfaces per card
Media transfer rate
Processors
Data buffers
Route table support
SDH (STM-1)
Max transmission unit
Cables
Two bi-directional interfaces
- single mode card
- multimode card
155 Mbps
40-MHz transmit processor, 40-MHz receive processor
4 MB on receive side, 4 MB on transmit side
150K entries, with hardware-assisted route table lookup
Complies with Synchronous Digital Hierarchy standards
9180 bytes
Single-mode cables: 9/125 micron optical fibre
Multi-mode cables: 62.5/125micron optical fibre
Connectors Duplex SC transceivers
Connector requirements Must meet JIS C 5973 standards
LASER components
Optical input
Class 1, 1310 nm LASER diodes
Single-mode: 32.5 dBm minimum, 8 dBm maximum
Multi-mode: 32.5 dBm minimum, 14 dBm maximum
Optical output (avg.)
Optical wavelength
Spectral width
Single-mode: 14 dBm minimum, 8 dBm maximum
Multi-mode: 19 dBm minimum, 14 dBm maximum
Single-mode: 1,261 nm min, 1,310 nm typical, 1,360 nm max
Multi-mode: 1,270 nm min, 1,310 nm typical, 1,380 nm max
Single-mode: 7.7 nm maximum
Multi-mode: 120 nm typical, 200 nm maximum
A-8 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF Specifications
Media card specifications
ATM OC-12c specifications
The ATM OC-12c media card has the following characteristics:
Table A-9. ATM OC-12c media card specifications
Element Value
Interfaces per card
Media transfer rate
Processors
Data buffers
Route table support
SDH (STM-1)
Max transmission unit
Cables
One bi-directional interface
- single mode card
- multimode card
622 Mbps
40-MHz transmit processor, 40-MHz receive processor
4 MB on receive side, 4 MB on transmit side
150K entries, with hardware-assisted route table lookup
Complies with Synchronous Digital Hierarchy standards
9180 bytes
Single-mode cables: 9/125 micron optical fibre
Multi-mode cables: 62.5/125micron optical fibre
Connectors Duplex SC transceivers
Connector requirements Must meet JIS C 5973 standards
LASER components
Optical input
Class 1, 1310 nm LASER diodes
Single-mode: 28 dBm minimum, 7 dBm maximum
Multi-mode: 26 dBm minimum, 14 dBm maximum
Optical output (avg.)
Optical wavelength
Spectral width
Single-mode: 15 dBm minimum, 8 dBm maximum
Multi-mode: 20 dBm minimum, 14 dBm maximum
Single-mode: 1,261 nm min, 1,310 nm typical, 1,360 nm max
Multi-mode: 1,270 nm min, 1,310 nm typical, 1,380 nm max
Single-mode: 7.7 nm maximum
Multi-mode: 120 nm typical, 200 nm maximum
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 A-9
GRF Specifications
Media card specifications
10/100Base-T specifications
The 10/100Base-T media card has the following characteristics:
Table A-10.10/100Base-T media card specifications
Element Value
Interfaces per card:
Media transfer rate
Processors
Data buffers
Route table support
4-port - four auto-sensing bi-directional interfaces
8-port - eight auto-sensing bi-directional interfaces
10 or 100 Mbps
40-MHz transmit processor, 40-MHz receive processor
4 MB on receive side, 4 MB on transmit side
150K entries, with hardware-assisted route table lookup
Max transmission unit 1500 bytes
Connectors RJ-45
Cables STP and UTP Category 5
Transmission distance 100 meters
HSSI specifications
The HSSI media card has the following characteristics:
Table A-11.HSSI media card specifications
Element Value
Interfaces per card
Media transfer rate
Processors
Data buffers
Two bi-directional interfaces
52 Mbps (OC-1), 45 Mbps (DS3), 34 Mbps (E3)
40-MHz transmit processor, 40-MHz receive processor
4 MB on receive side, 4 MB on transmit side
Route table support
Framing protocols
150K entries
Frame Relay, PPP, HDLC
Max transmission units Frame Relay-4352 bytes, PPP-1496 bytes, HDLC-4352 bytes
Connectors 2-row, 50-pin shielded tab connectors
Cables
Cable receptacles
Two 25 twisted-pair shielded coax cables
2-row, 50-pin receptacle heads
A-10 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF Specifications
Media card specifications
HIPPI specifications
The HIPPI media card has the following characteristics:
Table A-12.HIPPI media card specifications
Element
Interfaces per card
Media transfer rate
Value
One dual-simplex interface
800 Mbps
Data buffers
Route table support
4 MB input, 4 MB output
70K entries
Max transmission unit 65280 bytes
Transmission distance Point-to-point and LAN, up to 25 meters (82 feet)
Lucent certifies viability of GRF-to-GRF connections using 51-meter cables
Card connectors
Cable connectors
Cables
2-row, 100-pin panel-mount receptacle as specified in HIPPI-PH
2-row, 100-pin shielded tab connectors as specified in HIPPI-PH
Twisted-pair copper: 5, 25, and 51 meters, available from Lucent
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 A-11
GRF Specifications
Media card specifications
SONET OC-3c specifications
The SONET OC-3c media card has the following characteristics:
Table A-13. SONET OC-3c media card specifications
Element Value
Interfaces per card
Media transfer rate
Processors
Data buffers
Route table support
SDH (STM-1)
Max transmission unit
Transmission distance
Cables
One full duplex OC-3c SONET/STM-1 SDH
- supports an APS 1+1 Architecture Switching
- single mode, multimode
155 Mbps
40-MHz transmit processor, 40-MHz receive processor
4 MB on receive side, 4 MB on transmit side
150K entries, with hardware-assisted route table lookup
Complies with Synchronous Digital Hierarchy standards
9180 bytes
LAN, WAN distances with use of repeaters
Single-mode cables: 9/125 micron optical fibre
Multi-mode cables: 62.5/125micron optical fibre
Physical connectors Duplex SC transceivers
Connector requirements Must meet JIS C 5973 standards
LASER components
Optical input
Class 1, 1310 nm LASER diodes
Single-mode: 32.5 dBm minimum, 8 dBm maximum
Multi-mode: 32.5 dBm minimum, 14 dBm maximum
Optical output (avg.)
Optical wavelength
Spectral width
Single-mode: 14 dBm minimum, 8 dBm maximum
Multi-mode: 19 dBm minimum, 14 dBm maximum
Single-mode: 1,261 nm min, 1,310 nm typical, 1,360 nm max
Multi-mode: 1,270 nm min, 1,310 nm typical, 1,380 nm max
Single-mode: 7.7 nm maximum
Multi-mode: 120 nm typical, 200 nm maximum
A-12 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Warranty
Appendix B contains warranty information for the following Lucent products:
– GRF 400 (GRF-4-AC)
– GRF 400 (GRF-4-DC)
– GRF 1600 (GRF-16-AC)
– GRF 1600 (GRF-16-DC)
B
Product warranty
1 Lucent Technologies warrants that the GRF unit will be free from defects in material and workmanship for a period of twelve (12) months from date of shipment.
2 Lucent Technologies shall incur no liability under this warranty if:
– The allegedly defective goods are not returned prepaid to Lucent Technologies within thirty (30) days of the discovery of the alleged defect and in accordance with Lucent
Technologies’ repair procedures; or
– Lucent Technologies’ tests disclose that the alleged defect is not due to defects in material or workmanship.
3 Lucent Technologies’ liability shall be limited to either repair or replacement of the defective goods, at Lucent Technologies’ option.
4 Lucent Technologies MAKES NO EXPRESS OR IMPLIED WARRANTIES
REGARDING THE QUALITY, MERCHANTABILITY, OR FITNESS FOR A
PARTICULAR PURPOSE BEYOND THOSE THAT APPEAR IN THE APPLICABLE
Lucent Technologies USER'S DOCUMENTATION. Lucent Technologies SHALL NOT
BE RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL, OR PUNITIVE
DAMAGE, INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR
DAMAGES TO BUSINESS OR BUSINESS RELATIONS. THIS WARRANTY IS IN
LIEU OF ALL OTHER WARRANTIES.
Warranty repair
1 During the first three (3) months of ownership, Lucent Technologies will repair or replace a defective product covered under warranty within twenty-four (24) hours of receipt of the product. During the fourth (4th) through twelfth (12th) months of ownership, Lucent
Technologies will repair or replace a defective product covered under warranty within ten
(10) days of receipt of the product. The warranty period for the replaced product shall be ninety (90) days or the remainder of the warranty period of the original unit, whichever is
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 B-1
Warranty
FCC Part 15 Notice greater. Lucent Technologies will ship surface freight. Expedited freight is at customer's expense.
2 The customer must return the defective product to Lucent Technologies within fourteen
(14) days after the request for replacement. If the defective product is not returned within this time period, Lucent Technologies will bill the customer for the product at list price.
Out-of warranty repair
Lucent Technologies will either repair or, at its option, replace a defective product not covered under warranty within ten (10) working days of its receipt. Repair charges are available from the Repair Facility upon request. The warranty on a serviced product is thirty (30) days measured from date of service. Out-of-warranty repair charges are based upon the prices in effect at the time of return.
FCC Part 15 Notice
Warning: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his or her own expense.
The authority to operate this equipment is conditioned by the requirement that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Lucent Technologies.
B-2 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF 400 Agency Notices
This appendix contains Agency information for the GRF-4-AC and GRF-4-DC models.
C
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 C-1
GRF 400 Agency Notices
GRF 400 agency regulatory notices
GRF 400 agency regulatory notices
Agency status
Safety
CUL
TUV GS
- CAN/CSA-C22.2 No. 950
- EN 60950
EMC
FCC Class A
CE Mark
(commercial or industrial environments)
EN 55022 (Class A emissions)
EN 50082-2 (heavy industry immunity)
Canadian DOC Radio Interference Regulation, Class A
VCCI Class 1 (commercial or industrial environments)
Installation conditions and limitations
1 Enclosure must have all access panels in place and secured. All available slots must be filled with media cards or filler cards.
2 Substitution of unapproved or modified components, subassemblies, or modules may result in increased radiated emissions and/or increased susceptibility to radiated fields from other equipment.
3 All data, signal, and control cables connected to the equipment must be of the shielded type with metallic connector hoods, except for ethernet cables, fiber optic cables, and power cords, which are unshielded. Connectors with jackscrews should be securely tightened.
4 Excess cable lengths should be bound in a figure-eight pattern. Do not wind excess cable into circular coils.
Canadian notice
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
European Union notice
Warning:
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
C-2 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF 400 Agency Notices
GRF 400 agency regulatory notices
Federal Communications Commission notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
VCCI Class 1 notice
The GRF-4-AC and GRF-4-DC conform to Class 1 standards of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). Acceptance number: 44143
Caution:
This is a Class 1 product based on the standard of the Voluntary Control Council for
Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 C-3
GRF 400 Agency Notices
GRF 400 agency regulatory notices
Non-telecommunication port
(g0100)
HERGESTELLT-VON: Lucent Technologies, Inc.
High Performance Networking Division
10250 Valley View Road
Eden Prairie, MN 55344
GRF-4-AC GRF-4-DC MODELL:
STROMAUFNAHME:
Voltage:
Frequency:
Current:
100–240 VAC
50–60 Hz
6.0–3.0 A
48VDC–60VDC
N/A
7.0A
The Manufacturer / Supplier: Lucent Technologies, Inc.
High Performance Networking Division
10250 Valley View Road
Eden Prairie, MN 55344
Declares that: GRF-4-AC and GRF-4-DC are not intended to be connected to a public telecommunications network.
The connection of such equipment to a public telecommunications network in a European
Community Member State will be in violation of the national law implementing Directive
91/263/EEC on the approximation of the laws of the Member States concerning telecommunication terminal equipment, including mutual recognition of their conformity.
Der Hersteiler / Lieferant: Lucent Technologies, Inc.
High Performance Networking Division
10250 Valley View Road
Eden Prairie, MN 55344 erklärt daß: GRF-4-AC and GRF-4-DC nicht zum Anschluß an ein öffentliches Telekommunikationsnetz bestimmen sind.
Der Anschluß dieses Gerätes an ein öffentliches Telekommunikationsnetz in den
EG-Mitgliedstaaten verstößt gegen die jeweiligen einzeistaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angieichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einshließlich der gegenseitigen Anerkennung ihrer
Konformität.
C-4 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF 400 Agency Notices
GRF 400 agency regulatory notices
EC declaration: GRF-4-AC
EC Declaration of Conformity
(g0101)
High Performance Networking Division
10250 Valley View Road
Eden Prairie, MN 55344 declare under the sole responsibility that the
GRF-4-AC to which this declaration relates, meets the essential health, safety, and EMC requirements and is in conformity with the relative EC Directives and standards listed below:
EU EMC Directive 89/336/EEC
Essential health and safety requirements relating to electromagnetic compatibility
EN 55022 Class A
Limits and methods of measurement of radio disturbance characteristics of information technology equipment.
EN 50082-2
Electromagnetic compatibility - Generic immunity standard
Part 2: Industrial environment
EC Low Voltage Directive 73/23/EEC
Essential health and safety requirements relating to electrical equipment
EN 60950
Safety requirements of information technology equipment including electrical machines
The GRF-4-AC complies with all safety relevant provisions referring to
- Protection against electrical hazards
- Protection against mechanical and fire hazards
The safety issues of this information technology equipment type have been evaluated by a government accredited European third party organization.
The CE marking has been affixed on the device according to article 10 of the EC Directive
89/336/EEC.
CE
(g0102)
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 C-5
GRF 400 Agency Notices
GRF 400 agency regulatory notices
EC declaration: GRF-4-DC
EC Declaration of Conformity
(g0101)
High Performance Networking Division
10250 Valley View Road
Eden Prairie, MN 55344 declare under the sole responsibility that the
GRF-4-DC to which this declaration relates, meets the essential health, safety, and EMC requirements and is in conformity with the relative EC Directives and standards listed below:
EU EMC Directive 89/336/EEC
Essential health and safety requirements relating to electromagnetic compatibility
EN 55022 Class A
Limits and methods of measurement of radio disturbance characteristics of information technology equipment.
EN 50082-2
Electromagnetic compatibility - Generic immunity standard
Part 2: Industrial environment
EC Low Voltage Directive 73/23/EEC
Essential health and safety requirements relating to electrical equipment
EN 60950
Safety requirements of information technology equipment including electrical machines
The GRF-4-DC complies with all safety relevant provisions referring to
- Protection against electrical hazards
- Protection against mechanical and fire hazards
The safety issues of this information technology equipment type have been evaluated by a government accredited European third party organization.
The CE marking has been affixed on the device according to article 10 of the EC Directive
89/336/EEC.
CE
(g0102)
C-6 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF 1600 Agency Notices
This appendix contains Agency information for the GRF-16-AC and GRF-16-DC models.
D
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 D-1
GRF 1600 Agency Notices
GRF 1600 agency regulatory notices
GRF 1600 agency regulatory notices
Agency status
Safety
CUL
TUV GS
- CAN/CSA-C22.2 No. 950
- EN 60950
EMC
FCC Class A
CE Mark
(commercial or industrial environments)
EN 55022 (Class A emissions)
EN 50082-2 (heavy industry immunity)
Canadian DOC Radio Interference Regulation, Class A
VCCI Class 1 (commercial or industrial environments)
Installation conditions and limitations
1 Enclosure must have all access panels in place and secured. All available slots must be filled with media cards or filler cards.
2 Substitution of unapproved or modified components, subassemblies, or modules may result in increased radiated emissions and/or increased susceptibility to radiated fields from other equipment.
3 All data, signal, and control cables connected to the equipment must be of the shielded type with metallic connector hoods, except for ethernet cables, fiber optic cables, and power cords, which are unshielded. Connectors with jackscrews should be securely tightened.
4 Excess cable lengths should be bound in a figure-eight pattern. Do not wind excess cable into circular coils.
Canadian notice
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
European Union notice
D-2 October, 1998
Warning:
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
GRF 400/1600 Getting Started - 1.4 Update 2
GRF 1600 Agency Notices
GRF 1600 agency regulatory notices
Federal Communications Commission notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
VCCI Class 1 notice
The GRF-16-AC and GRF-16-DC conform to Class 1 standards of the Voluntary Control
Council for Interference by Information Technology Equipment (VCCI). Acceptance number:
46264
Caution:
This is a Class 1 product based on the standard of the Voluntary Control Council for
Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 D-3
GRF 1600 Agency Notices
GRF 1600 agency regulatory notices
Non-telecommunication port
(g0100)
HERGESTELLT-VON: Lucent Technologies, Inc.
High Performance Networking Division
10250 Valley View Road
Eden Prairie, MN 55344
GRF-16-AC GRF-16-DC MODELL:
STROMAUFNAHME:
Voltage:
Frequency:
Current:
100–240 VAC
50–60 Hz
12.0–6.0 A
48VDC–60VDC
N/A
25A
The Manufacturer / Supplier: Lucent Technologies, Inc.
High Performance Networking Division
10250 Valley View Road
Eden Prairie, MN 55344
Declares that: GRF-16-AC and GRF-16-DC are not intended to be connected to a public telecommunications network.
The connection of such equipment to a public telecommunications network in a European
Community Member State will be in violation of the national law implementing Directive
91/263/EEC on the approximation of the laws of the Member States concerning telecommunication terminal equipment, including mutual recognition of their conformity.
Der Hersteiler / Lieferant: Lucent Technologies, Inc.
High Performance Networking Division
10250 Valley View Road
Eden Prairie, MN 55344 erklärt daß: GRF-16-AC and GRF-16-DC nicht zum Anschluß an ein öffentliches Telekommunikationsnetz bestimmen sind.
Der Anschluß dieses Gerätes an ein öffentliches Telekommunikationsnetz in den
EG-Mitgliedstaaten verstößt gegen die jeweiligen einzeistaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angieichung der Rechtsvorschriften der Mitgliedstaaten über
Telekommunikationsendeinrichtungen einshließlich der gegenseitigen Anerkennung ihrer
Konformität.
D-4 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
GRF 1600 Agency Notices
GRF 1600 agency regulatory notices
EC declaration: GRF-16-AC
EC Declaration of Conformity
(g0101)
High Performance Networking Division
10250 Valley View Road
Eden Prairie, MN 55344 declare under the sole responsibility that the
GRF-16-AC to which this declaration relates, meets the essential health, safety, and EMC requirements and is in conformity with the relative EC Directives and standards listed below:
EU EMC Directive 89/336/EEC
Essential health and safety requirements relating to electromagnetic compatibility
EN 55022 Class A
Limits and methods of measurement of radio disturbance characteristics of information technology equipment.
EN 50082-2
Electromagnetic compatibility - Generic immunity standard
Part 2: Industrial environment
EC Low Voltage Directive 73/23/EEC
Essential health and safety requirements relating to electrical equipment
EN 60950
Safety requirements of information technology equipment including electrical machines
The GRF-16-AC complies with all safety relevant provisions referring to
- Protection against electrical hazards
- Protection against mechanical and fire hazards
The safety issues of this information technology equipment type have been evaluated by a government accredited European third party organization.
The CE marking has been affixed on the device according to article 10 of the EC Directive
89/336/EEC.
CE
(g0102)
GRF 400/1600 Getting Started - 1.4 Update 2 October, 1998 D-5
GRF 1600 Agency Notices
GRF 1600 agency regulatory notices
EC declaration: GRF-16-DC
EC Declaration of Conformity
(g0101)
High Performance Networking Division
10250 Valley View Road
Eden Prairie, MN 55344 declare under the sole responsibility that the
GRF-16-DC to which this declaration relates, meets the essential health, safety, and EMC requirements and is in conformity with the relative EC Directives and standards listed below:
EU EMC Directive 89/336/EEC
Essential health and safety requirements relating to electromagnetic compatibility
EN 55022 Class A
Limits and methods of measurement of radio disturbance characteristics of information technology equipment.
EN 50082-2
Electromagnetic compatibility - Generic immunity standard
Part 2: Industrial environment
EC Low Voltage Directive 73/23/EEC
Essential health and safety requirements relating to electrical equipment
EN 60950
Safety requirements of information technology equipment including electrical machines
The GRF-16-DC complies with all safety relevant provisions referring to
- Protection against electrical hazards
- Protection against mechanical and fire hazards
The safety issues of this information technology equipment type have been evaluated by a government accredited European third party organization.
The CE marking has been affixed on the device according to article 10 of the EC Directive
89/336/EEC.
CE
(g0102)
D-6 October, 1998 GRF 400/1600 Getting Started - 1.4 Update 2
Index
"classic" cards ,
"Q" cards, definition ,
10/100Base-T media card
4 port/8 port
4-port face plate diagram
8-port face plate diagram
board specifications ,
cables
LEDs ,
A
A / B interfaces, connectors (FDDI)
A and B keys
AC receptacle, type ,
AC voltage, characteristics ,
,
administrative LAN connection LEDs, GRF 1600
connection LEDs, GRF 400 ,
LED ,
,
preset IP address ,
site-supplied cable
administrative log on (as netstar) ,
altitude
ATM OC-12c media card attaching cables ,
face plate diagram ,
LASER component
LEDs ,
ATM OC-3c media card board specifications ,
face plate diagram ,
LASER component
LEDs ,
audible beeps ,
B backplane, for GRF 1600
backplane, for GRF 400 ,
battery on control board ,
beeps, when sounded ,
GRF 400/1600 Getting Started - 1.4 Update 2 boot process
BOOT-REQUESTED, state of ,
bypass switch (FDDI) ,
manual control ,
C cables attaching 10/100Base-T ,
attaching ATM ,
attaching FDDI ,
attaching HIPPI ,
attaching HSSI ,
attaching media interface
attaching SONET OC-3c ,
attaching to control board ,
types required
chassis cooling
dimensions
power usage ,
,
checkout, media card ,
clearance for servicing GRF 1600 ,
for servicing GRF 400 ,
CLI and UNIX passwords
com bus
commands
"gr" man pages available
,
communications bus ,
clock cycle ,
configuration script first-time power on ,
,
how to re-run ,
configuration tasks in CLI or UNIX shell ?
,
configuring a PCMCIA disk device ,
configuring a PCMCIA modem ,
,
configuring an NFS file system ,
CONFIGURING, state of ,
connector keys
installing and removing ,
October, 1998 Index-1
Index
D conslog, gr.console log ,
control board attaching Ethernet LAN ,
cable connector sites ,
,
control board, GRF 1600 battery for BIOS and clock ,
description and diagram
LEDs ,
reset button
speaker ,
control board, GRF 400 battery for BIOS and clock ,
description and diagram
LEDs ,
reset button
speaker ,
specifications ,
using ping command
cooling requirements
GRF 1600
GRF 400
cooling, affected by empty slots
csconfig command ,
D
DAS settings ,
DC power requirements control board ,
media cards ,
de0 interface
,
default route, restriction ,
dimensions, GRF chassis ,
DIN connector, on FDDI card
DNS (named)
DUMPING, state of ,
dumps from GRF (bsdx.core) ,
from media cards (grdump,n.x.gz) ,
panic dumps saved ,
sending to external flash device ,
E environment, operating specifications
ESD protecting a media card ,
ESD requirements
,
ESD requirements, when handling cards ,
/etc/fstab editing for logging
Index-2 October, 1998
/etc/grclean.conf
/etc/grclean.logs.conf
,
/etc/syslog.conf
editing for logging
Ethernet, administrative connecting to control board ,
preset IP address
Ethernet, fast Ethernet
external flash device ,
configure for dumps ,
configure for local logging
F face plates on empty slots ,
fans
GRF 400
replacement option
fans, GRF 1600 chassis ,
internal power supply ,
FDDI cables
connector keys
dual attach A and B interfaces ,
installing an optical bypass ,
master and slave interfaces
SAS and DAS options ,
FDDI media card board specifications
face plate diagram
LEDs ,
fiber optic cable ,
,
flash memory
GRF 1600 options
GRF 400 options
flash memory, code burn-ins ,
fusing, power supply ,
G gr.console log grconslog command,
accessing ,
grcard command checking card status ,
media card status ,
grconslog command ,
grdump.n.x.gz files ,
GRF 400/1600 Getting Started - 1.4 Update 2
GRF chassis specifications
operating altitude ,
operating environment ,
operating humidity ,
operating temperatures ,
power on procedure
GRF 1600
2-person moving team ,
AC power supply locking clamp
AC power supply, installing
backplane ,
cable for administrative LAN
chassis fans
clearances for servicing ,
control board speaker ,
diagram of cabling side ,
exhaust requirements ,
factory-shipped components
features
grounding requirements ,
installation ,
installation overview ,
,
installing side rails
items shipped
LED descriptions ,
min number of cards installed
minimum rack depth
organization of chassis components ,
power cord requirements
power on procedure
power supply failure ,
power supply failures ,
power supply fans ,
power supply LEDs
power supply locking tab, clamp ,
,
powering off
,
rack grounding site ,
rack power requirements ,
rack-mounting procedure
side rails requirement
site-supplied components ,
slot numbering diagram
switch board
system memory (RAM)
temp, power monitoring
using side rails ,
ventilation for rack-mounting ,
,
voltage requirements ,
weight ,
wrist strap ground ,
GRF 400
AC power supply
,
AC power supply incompatibilities
AC power supply, installing
Astec AC power supply ,
backplane ,
GRF 400/1600 Getting Started - 1.4 Update 2
Index
H cable for administrative LAN
chassis fans ,
clearances for servicing ,
control board speaker ,
DC power supply
DC power supply, installing ,
DC power supply, site alarm option ,
DC power supply, wiring ,
exhaust requirements ,
features
grounding requirements ,
installation
installation overview ,
items shipped ,
LED descriptions
power cord requirements
power on procedure
power supply failure
power supply failures
,
powering off ,
,
rack-mounting ,
site-supplied components ,
slot numbering diagram ,
system memory (RAM) ,
temp, power monitoring
weight ,
Zytec AC power supply ,
grflash command ,
grms command resetting system
using instead of shutdown
grounding
GRF 1600 requirements
grreset command ways to reset media cards
grsavecore command formatting kernel dumps ,
grsnapshot command
,
grwrite command ,
H halting system software grms command ,
HELD-RESET, state of ,
HIPPI media card board specifications
cables ,
face plate diagram ,
LEDs ,
hot swap, media cards ,
HSSI media card attaching cables ,
October, 1998 Index-3
I
Index board specifications ,
face plate diagram ,
LEDs ,
humidity, operating level
I iflash command
PCMCIA support
inserting media cards
,
inserting the SP Switch Router Adapter card ,
installation checkout determining state of media card
pinging boards ,
resetting media cards
resetting system remotely ,
installation overview for GRF
internal flash device ,
,
IP address preset for administrative LAN ,
IP switch control board
K keys for FDDI/Q cards ,
L
LAN connector to administrative LAN ,
LEDs
10/100Base-T media card ,
ATM media card ,
ATM OC-12c media card
control board ,
,
Ethernet media card
FDDI media card
HIPPI media card ,
HSSI media card ,
SONET media card
loading differences, media cards
LOADING, state of ,
log files
logging locally to external flash ,
options ,
setting up syslog server ,
to external flash device ,
Index-4 October, 1998 to NFS-mounted file system ,
logging, specify log directory ,
logical ring (FDDI) ,
logs descriptions of ,
how to access a log file ,
how to enable remote logging ,
sending to external flash device
M
M and S connectors, FDDI ,
man pages ,
master/slave interfaces, connectors (FDDI) ,
media board, part of media card ,
media cables
10/100Base-T
ATM ,
FDDI ,
HIPPI
HSSI
SONET
media card dimensions, weight
minimum installed, GRF 1600 ,
media cards components ,
,
DC power requirements
determining status
differences in loading
face plate screws
flash memory burn-in ,
hot swap guidelines ,
how to replace ,
how to return to Ascend
inserting into chassis
list of states
removal warning
resetting ,
serial and part numbers
,
using ping command
media interface cables ,
memory upgrading system RAM ,
upgrading system RAM, GRF 400 ,
memory, control board description ,
,
upgrading RAM
modem how to connect PCMCIA
model certified for GRF
,
more command
using to display log file contents , 4-10
GRF 400/1600 Getting Started - 1.4 Update 2
N named
nesting CLI / UNIX sessions, not possible
netstart ,
network logging setting up remote server ,
via configuration script ,
NFS file system de0 interface ,
set up for GRF ,
NOT-RESPONDING, state of ,
null modem cables to VT-100 ,
O on/off switch ,
optical bypass switch (FDDI) ,
out of band access
P packaging a media card for return ,
PANIC, state of ,
password changing for root
preset for root
passwords preset ,
UNIX and CLI differences ,
PCMCIA modem compatible with GRF ,
how to connect ,
PCMCIA modem device for GRF systems ,
PCMCIA slots ,
,
PCMCIA storage use for logging/backup ,
PCMCIA storage devices for GRF systems ,
ping command
ping control board ,
ping media cards ,
power supplies capacity
safely powering off ,
power supplies, GRF 1600
48V option
fusing ,
,
redundant ,
GRF 400/1600 Getting Started - 1.4 Update 2 safely powering off ,
voltage cautions ,
power supplies, GRF 400
DC option ,
fusing ,
installing DC unit
negative 48V option ,
safely powering off ,
,
voltage cautions ,
,
wiring DC unit
power supply failure LED ,
,
power usage ,
,
POWER-UP, state of ,
Index
N
Q
Q card, in grcard display ,
R rack depth requirements for GRF 1600 ,
rack-mounting requirements for GRF 400 ,
rack-mounting procedure for GRF 1600 ,
reboot, remotely using shutdown command ,
rebooting system software grms command ,
redundant power supplies
GRF 400, AC ,
GRF 400, DC ,
redundant power supplies, GRF 1600
AC units ,
remote logging ,
remote logging, setting up ,
reset button
reset button, GRF 1600
reset button, GRF 400
reset command after attaching cables ,
reset operating system
reset process
returning a card procedure ,
RMA number ,
RJ45 modular connector ,
RMA number, how to obtain ,
October, 1998 Index-5
Index
S
RMS node control board replacement
root changing preset Ascend password ,
logon
RS-232 connection, on control board ,
RUNNING, state of
S
SAS settings ,
script first-time power on ,
serial daughter card
serial number, media card ,
serial port ,
,
on GRF 1600 ,
on GRF 400 ,
shutdown command resetting system
using instead of grms ,
shutting down system software grms command
side rails requirements for GRF 1600
side rails, GRF 1600 rack support
single attach connectors ,
slave interface/connector (FDDI) ,
slot number in grreset command ,
in ping command
slot number, GRF 1600 order in chassis ,
slot number, GRF 400 order in chassis ,
SONET OC-3c media card attaching cables ,
board specifications ,
face plate diagram ,
LASER component
,
LEDs ,
SP Switch Router wrist strap connector sites ,
SP Switch Router Adapter card inserting into router ,
removal warning ,
speaker
GRF 1600 control board ,
GRF 400 control board ,
speaker, on control board ,
specifications general for control board ,
Index-6 October, 1998 general for GRF 400 chassis
general for media cards ,
STATE UNKNOWN, state of ,
states, list for media cards ,
syslog server
de0 interface
how to set up ,
syslog.conf
editing for network logging ,
editing via configuration script ,
syslogd remote logging server ,
T temp command on GRF 1600 ,
on GRF 400 ,
temperature, operating levels
terminal server, as modem option ,
terminal settings, VT-100 ,
,
touch command, use on syslog server ,
U
UNIX passwords ,
V
/var/crash, dump directory
/var/logs directory contents ,
/var/portcards, dump directory ,
ventilation for GRF 1600 ,
for GRF 400 ,
for GRF 400 rack-mounting ,
VT-100 terminal attaching to the GRF
boot requirement ,
,
null modem cabling
on GRF 1600 ,
,
on GRF 400 ,
settings ,
,
W weight of GRF 400 ,
, weight, of GRF 1600
wrist strap, connector sites
GRF 400/1600 Getting Started - 1.4 Update 2