Amerec AX Generator, "AX4.5", "AX6", "AX7.5", "AX9", "AX11" & "AX14" Instructions


Add to my manuals
24 Pages

advertisement

Amerec AX Generator,

AX INSTALLATION AND SERVICE INSTRUCTIONS

ELITE

PURE 2.0

AX STEAM GENERATOR

These instructions apply to the

AX4.5, AX6, AX7.5, AX9, AX11 and AX14

208V and 240V 1/3 Phase Models.

(Also use 240V models for 415V~N3 installations)

SAVE THESE INSTRUCTIONS

READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.

POST SAFETY "WARNING" LABEL OUTSIDE STEAMBATH. LABEL

SHOULD BE POSTED ON OR ADJACENT TO DOOR TO STEAM

ROOM IN COMMERCIAL INSTALLATIONS.

SECTION 1: GENERAL INFORMATION

Amerec Steamers With Elite or Pure 2.0 controls

Amerec steam generators are tested by Intertek-ETL Laboratory. The steam generators come assembled and ready for installation. Check that the size and rating of the generator is suitable for your application, refer to

CAUTION

Electrical grounding is required on all

AMEREC Steam bath Generators.

All electrical supplies should be disconnected when servicing generator.

All wiring must be installed by a licensed electrical contractor in accordance with local and national codes.

All plumbing must be installed by a licensed plumber in accordance with all applicable local and national codes.

AX series generators are for indoor use only.

AX series generators are not for space heating purposes.

Be certain that steam bath enclosures are properly sealed to avoid water damage from escaping steam. It is recommended that 100% silicone caulk be used to seal all pipes and fittings.

Steam must be prevented from escaping into the wall cavity.

Never shut off the water to a steam generator that is in use.

Electric Shock Hazard - High voltage exists within this equipment. There are no user serviceable parts in this equipment.

the AX Steam Room Sizing and Rough-in Guide (Amerec doc 4211-36).

The AX steamers may be connected as a ganged system where one Steamer controls one or two other steamers.

Bath controls connect to the primary steamer and the primary steamer connects to the second steamer (and third steamer, if installed). This provides more power for large rooms and light commercial use. Note : An Elite control is required with a ganged system!

See appendix to this document for details.

We recommend choosing steamers which are closely matched in power. The highest kW steamer should be the primary unit. Each steamer should have its own automatic drain.

For commercial use, we recommend checking with your local inspectors to confirm the AX system is acceptable for your use. Many jurisdictions will require an ASME boiler for commercial use: AX steamers are not boilers .

Note : The AX steamer may be configured for single or three phase power during installation

An exhaust fan installed outside the steam room is strongly recommended.to remove excess steam from the bathroom or shower area.

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 1 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

TABLE OF CONTENTS

Section Description Page

Important Safety Instruction 3-6

6

7

4

5

1

2

3

Mounting the Generator

Water Quality Requirements

Plumbing Instructions

Wiring Instructions

Bath Control Installation

Initial Start

Contact Information

Electrical Information Chart

Wiring Diagrams

Appendix 1: Systems Installation

7-8

8

9-11

12

13-14

14-15

15

16

17-18

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 2 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

Thank you for purchasing your new AMEREC AX steam generator.

If we can be of any assistance do not hesitate to call our Technical Support at 1-800-363-0251.

FOR THE SAFETY OF YOU AND YOUR FAMILY OR CUSTOMERS, PLEASE READ THE

FOLLOWING WARNINGS AND ALL INSTRUCTIONS BEFORE USING YOUR STEAMBATH.

POST "STEAMBATH INSTRUCTIONS" LABEL OUTSIDE STEAMBATH FOR SAFETY WARNINGS.

SAVE THIS MANUAL

FOR THE SAFETY OF YOU AND YOUR FAMILY OR CUSTOMERS, PLEASE READ THE

FOLLOWING WARNINGS AND ALL INSTRUCTIONS BEFORE USING YOUR STEAMBATH.

POST "STEAMBATH INSTRUCTIONS" LABEL OUTSIDE STEAMBATH FOR SAFETY WARNINGS.

WARNING

Electric Shock Hazard - High voltage exists within this equipment. Disconnect all electrical power before servicing the generator. All installation and service to this equipment should be performed by qualified licensed personnel in accordance with local and national codes. There are no user serviceable parts in this equipment.

Electrical grounding is required on all AMEREC steambath generators. The generator is designed for hookup with copper wire only, 75°C or better.

Wire the controls exactly as described. Do not connect any additional wiring or power supplies to the controls or their terminals in the generator.

Service only by authorized personnel!

All plumbing must be installed by a licensed plumber in accordance with all applicable local and national codes.

Install indoors only. Protect from freezing. Generator must be level side to side and end to end.

The pressure relief valve and generator drain must be installed in such a fashion that the risk of scalding is reduced to a minimum. Draining these outlets into the steam room may present a scald hazard and may damage materials used to construct the room.

Danger To reduce the risk of explosions, do not interconnect t steam lines!!

Caution The steam outlet carries hot vapor! A separate steam line is required for each steam outlet.

Do not connect a valve or shut-off in the steam line! Avoid traps and valleys in the steam line where water could collect and cause a steam blockage. The hot steam line must be insulated against user contact.

Do not install the steam head near a bench or where steam may spray or where condensation will drip on the user as this will present a scald hazard.

Be certain that steambath enclosures are properly sealed to avoid water damage from escaping steam. It is recommended that 100% silicone caulk be used to seal all pipes and fittings. Steam must be prevented from escaping into the wall cavity. Centering the steam pipe is critical in rooms made of plastic, acrylic, resin, fiberglass or similar materials. Allowing the steam pipe to touch materials not rated 240°F (115°c) or higher will result in damage to these materials.

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 3 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

Merci pour l'achat de votre nouveau AMEREC AX générateur de vapeur.

Si nous pouvons vous être utiles n'hésitez pas à appeler notre assistance technique au 1-800-363-0251.

POUR LE SËCURITË DE VOTRE FAMILLE ER VOUS OU CLIENTS, VEUILLEZ

LIRE LES AVERTISSEMENTS SUIVANTS ET TOUTES LES INSTRUCTIONS AVANT

D'UTILISER VOTRE BAIN DE VAPEUR.

POST "BAIN DE VAPEUR" LABEL HORS D UN BAIN DE d'INSTRUCTIONS

POUR DES AVERTISSEMENTS EN MATIÈRE DE SÉCURITÉ.

ENREISTREZ CE MANUEL

POUR LA SËCURITË DE VOTRE FAMILLE ET VOUS OU VOS CLIENTS, VEUILLEZ LIRE

APRèS AVERTISSEMENTS ET TOUTES LES INSTRUCTIONS AVANT D'UTILISER VOTRE BAIN DE VAPEUR.

POST "BAIN DE VAPEUR" LABEL HORS D' UN BAIN DE VAPEUR D'INSTRUCTIONS POUR DES

AVERTISSEMENTS EN MATIÈRE DE SËCURITË.

AVERTISSMENT

Risque de choc électrique - Haute tension existe au sein de ce matériel. Débranchez toute source d'alimentation avant de procéder à l'entretien du générateur. Toutes les instructions d'installation et service à cet équipement doit

être effectuée par du personnel autorisé qualifié conformément aux codes locaux et nationaux. Il n'y a pas de pièce réparable par l'utilisateur à cet équipement.

Mise à la terre électrique est requis sur tous les générateurs bain de vapeur AMEREC. Le générateur est conçu pour connecter un fil de cuivre uniquement, 75 °C ou mieux.

Câbler le contrôle très exactement comme indiqué. Ne connectez aucun câblage supplémentaire ou blocs d'alimentation pour les commandes ou leurs terminaux dans le générateur.

Service uniquement par le personnel autorisé!

Toute la tuyauterie doit être installé par un plombier sous licence conformément à tous les codes locaux et nationaux applicables.

Installer à l'intérieur uniquement. Protéger du gel. Générateur doit être mise à niveau latérale et l'extrémité à l'autre.

La valve de limitation de pression et purge du générateur doit être installé de telle façon que le risque de brûlure est réduit à un minimum. Vidange de ces prises dans la salle de vapeur peut présenter un risque de brûlure et peut endommager les matériaux utilisés pour construire la salle.

Danger Pour réduire les risques d'explosion, ne pas connecter les conduites de vapeur t!!

Attention La sortie vapeur transporte vapeur chaude ! Une conduite de vapeur distincte est requise pour chaque sortie vapeur. Ne connectez pas une valve ou l'arrêter dans la conduite de vapeur! Éviter les pièges et les vallées dans la conduite de vapeur où l'eau pourrait recueillir et provoquer un blocage de vapeur. La vapeur chaude ligne doit être isolée par rapport au contact de l'utilisateur.

Ne pas installer la tête de vapeur près d'un banc ou où la vapeur peut pulvériser ou où la condensation s'égoutter sur l'utilisateur comme cela présentera un risque de brûlure.

Etre certain que le bain de vapeur boîtiers sont étanches afin d'éviter les dégâts d'eau de s'échapper la vapeur. Il est recommandé que 100% mastic au silicone utilisée pour obturer tous les raccords et tuyaux. La vapeur doit être empêché de s'échapper dans la cavité du mur. Centrage du tube à vapeur est critique dans les chambres faites de plastique, de l'acrylique, résine, la fibre de verre ou des matériaux similaires. Permettant le tube à vapeur pour toucher les matériaux non coté 115°C ou plus aura pour effet d'endommager ces matériaux.

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 4 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

POST "WARNING LABEL OUTSIDE STEAMBATH FOR SAFETY WARNINGS

Étiquette d'avertissement "Extérieur poste baiin de vapeur pour les avertissements relatifs à la sécurité

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 5 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

IMPORTANT USER SAFETY INSTRUCTIONS

1. READ AND FOLLOW ALL INSTRUCTIONS .— SAVE THESE INSTRUCTIONS!

2. The steam bath is not intended for use by anyone (including children) with reduced physical, sensory or mental capabilities or who lack experience or knowledge, unless they have supervision or training on the use of the steam bath by a person responsible for their safety.

3. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. Ensure they do not play in the steam bath.

4. WARNING - To reduce the risk of injury: a. The wet surfaces of steam enclosures may be slippery. Use care when entering or leaving. b. The steam head is hot. Do not touch the steam head and avoid the steam near the steam head. c. Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body’s ability to regulate its internal temperature (hyperthermia). Limit your use of steam to 10 to 15 minutes until you are certain of your body’s reaction. d. Excessive temperatures have a high potential for causing fetal damage during the early months of pregnancy. Pregnant or possibly pregnant women should consult a physician regarding correct exposure. e. Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a steam bath. f. Persons using medication should consult a physician before using a steam bath since some medication may induce drowsiness while other medications may affect heart rate, blood pressure and circulation.

5. WARNING - Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37°C. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness and fainting. The effects of hyperthermia include: a. Failure to perceive heat: b. Failure to recognize the need to exit the steam bath: c. Unawareness of impending risk: d. Fetal damage in pregnant women: e. Physical inability to exit the steam bath: and f. Unconsciousness.

6. WARNING - The use of alcohol, drugs or medication can greatly increase the risk of hyperthermia

1. Lire et suivre toutes les instructions . -- Conservez ces instructions !

2. Le bain de vapeur n'est pas destiné à être utilisé par toute personne (y compris les enfants) avec toutes leurs capacités physiques, sensorielles ou mentales ou qui manquent d'expérience ou de connaissances, à moins qu'ils aient la supervision ou de la formation sur l'utilisation du bain de vapeur par une personne responsable de leur sécurité.

3. Avertissement : Pour réduire les risques de blessures, ne pas permettre aux enfants d'utiliser ce produit, sauf s'ils sont étroitement surveillés en tout temps. S'assurer qu'ils ne jouent pas dans le bain de vapeur.

4. Avertissement : pour limiter les risques de blessure : a. Les surfaces mouillées de boîtiers de vapeur peut être glissant. Soyez prudent lorsque vous entrant ou sortant. b. La tête de vapeur est chaud. Ne pas toucher la tête de vapeur et éviter la vapeur près de la tête de vapeur. c. Une utilisation prolongée de la chaudière à vapeur peut augmenter excessivement la température du corps humain et d interne nuisent à la capacité du corps de régler sa température interne (hyperthermie). Limitez votre consommation de vapeur pour 10 à 15 minutes jusqu'à ce que vous soyez certain de la réaction de votre corps. d. Des températures excessives ont un haut potentiel de causer de dommages foetaux pendant les premiers mois de la grossesse.

Enceinte ou peut-être les femmes enceintes devraient consulter un médecin au sujet de l'exposition correcte. e. Les personnes obèses et les personnes ayant des antécédents de maladie du coeur, tension artérielle basse ou élevée, des problèmes du système circulatoire ou de diabète devraient consulter un médecin avant d'utiliser un bain de vapeur. f. Les personnes qui utilisent ces médicaments devraient consulter un médecin avant d'utiliser un bain à vapeur depuis quelques médicaments peut induire une somnolence tandis que d'autres médicaments peuvent affecter la fréquence cardiaque, la tension artérielle et de la circulation.

5. Avertissement - L'hyperthermie survient lorsque la température interne du corps atteint un niveau à plusieurs degrés au-dessus de la normale de la température corporelle de 37 °C. Les symptômes de l'hyperthermie comprennent une augmentation de la température interne du corps, sensation vertigineuse, léthargie, somnolence et d'évanouissement. Les effets de l'hyperthermie comprennent : a. L'incapacité de percevoir la chaleur b. L'incapacité à reconnaître la nécessité de quitter le bain de vapeur : c. La méconnaissance de l'imminence d'un risque : d. Dommages au foetus chez les femmes enceintes : e. Incapacité physique pour quitter le bain de vapeur : et f. L'inconscience.

6. Avertissement hyperthermie

- La consommation d'alcool, de drogues ou de médicaments peut augmenter considérablement le risque d'une

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 6 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

SECTION 1: MOUNTING THE STEAM GENERATOR

DIAGRAM 1

Steamer must be level

End-to-End and

Front to Back

0.8”

[20,3 mm]

DIAGRAM 2

14.5” [368 mm]

13.2”

[335,3 mm]

Leave 13” [330 mm]

Service Clearance

The AMEREC steam generator can be hung on a wall or sit on its base. The best mounting location will satisfy all or most of the following:

WARNING:

The generator will not operate properly, unless it is mounted level with the arrows pointed up

1. The generator should be installed in a dry, well ventilated area . Suggested locations are under a vanity, in a closet, attic, crawl space or basement. Do not mount outdoors .

2. If the generator will be in an area difficult to access, the water supply should be equipped with easily access water shut-off valve in case of emergency.

3. If the steam line is in an area where the temperature will be below 39°F (4°C) best results can be obtained by insulating the steam pipe. Do Not mount the generator in an area subject to freezing .

4. The generator must be mounted in a minimum 7 cubic feet (0,2 cubic meter) space.

5. The location must allow access for service ! Provide clearance for plumbing and electrical service and for element removal. See Diagram 1.

6. The steam line should slope to allow condensation to drain. The mounting location should minimize the number of bends and elbows in the steam line

7. The mounting location should allow for a drain hook up.

8. The steam line should be less than 20 ft (6 m) long; 10 ft (3 m) is preferred. Steam lines over 20ft (6 m) long should be insulated.

WARNING

• There must be no dips or valleys in the steam line.

• Install the steam head so as to avoid potential user direct contact with the steam or where condensation may drip on the user as this may present a scald hazard.

• Do Not install any valves or other shut-off devices in the steam line!

• Do Not interconnect steam lines! A separate steam line is required for each generator!

• Do Not connect the drain line to the steam line or allow the drain empty into the steam room!

• Do Not connect the pressure relief valve into the steam line or vent it where someone nearby could be scalded!

Do Not allow the relief valve to vent into the steam room!

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 7 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

SECTION 1: MOUNTING THE STEAM GENERATOR (continued)

1. WALL MOUNTING: Remove the side cover. Note the location of the mounting holes on the back of the generator. The screws must set directly into studs or equivalent supports. Drill pilot holes on 14-1/2”

(368 mm) centers and install the two #10 1½" screws, provided.

See at right.

a) Carefully hang the generator on the two screws. Tighten the screws. b) The generator may be further secured with two screws mounted on the same 14-1/2” (368 mm) centers as shown. c) Replace the front cover with its four screws.

2. FLOOR MOUNTING: a) In general, the width of the unit allows it to sit on a shelf, across the ceiling joists or on a floor. The generator must be restrained from moving. Normally, the piping will provide adequate support. If not, additional support must be provided. b) All floor installed generators must provide for routine draining of the tank and for draining the safety valve’s outlet.

SECTION 2: WATER QUALITY REQUIREMENTS

WALL MOUNTING

14.5” [368 mm]

14.5” [368 mm]

The nature of a boiler or steam bath generator requires testing of the feedwater to avoid potential high concentrations of impurities which can cause a deposit or scale to form on the internal surfaces. This deposit or scale can interfere with the equipment's proper operation and even cause premature boiler or generator failure. Concentration of impurities is generally controlled by treating the feedwater and or "blowing down" the generator or boiler when it is not heating. The "blow down" process involves removing a portion of the tank water with high solid concentration and replacing it with makeup water.

This is particularly important in areas with high calcium levels and other water quality problems. Calcium build-up can cause poor steamer performance and damage the heating elements!

Be especially careful to prevent foaming in the steamer’s water!

Foaming water will affect the water level measuring systems in steamers and boilers, causing operation problems and possibly leading to early element failures!

To insure proper operation, the water supply should be tested prior to operating the equipment. There are several treatment processes which can be used if you have a problem with hard water. A local reliable water treatment company can recommend the appropriate treatment if required. The recommended feedwater quality is listed on the next page.

Recommended Feedwater Quality

Hardness

T-Alkalinity

Silica Range

PH (strength of alkalinity)

10 – 30 ppm - (0.5 - 1.75 gpg)

150 – 700 ppm - (8.75 - 40.8 gpg)

15 – 25 ppm - (1.28 - 1.45 gpg)

10.5 -- 11.5

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 8 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

IMPORTANT!

Regular maintenance will help your steamer work properly for a long time. Check for leaks, loose or damaged wires, signs of corrosion and calcium build up in the tank on the level probe.

SECTION 3: PLUMBING INSTRUCTIONS

All plumbing shall be installed by a licensed plumber and conform with local & national codes.

Materials Needed:

• 3/8NPT, 1/2NPT and 3/4NPT unions: recommended to allow easy disconnect of steamer for servicing

• 3/8" copper pipe and 3/8” male NPT adapter for the water supply to the generator.

• 3/8" water supply shut-off valve.

• 3/8" supply valve housing and filter (optional depending on local water conditions).

• 1/2" copper pipe and (2) 1/2" male NPT adapters for the steam line between the generator and the steam room outlet.

• 3/4" copper pipe and 3/4" male NPT adapter for the tank drain.

• 3/4" copper pipe, fittings, and a union for the Pressure Relief Safety Valve drain.

• Tube 100% silicone caulk.

• Pipe compound suitable for drinking water use at more than 212°F (100°C).

1. INSTALL WATER LINE Connect a cold water line to the generators water valve. The valve input is 3/8” NPT. A shut-off valve should be placed in the line for each generator to allow easier servicing later, if needed, and for emergency shut-off. Make sure the shut-off is open, providing water to the generator before first turning the on.

IMPORTANT

• Water pressure required: 20-100 psi (138-690 kPa)

• If the generator is mounted in a place difficult for the homeowner to access, the water supply shut-off valve should be located where it can be quickly accessed in an emergency.

• Do not use a saddle valve or saddle fitting for the water shut-off valve.

• Flush water supply line before final hookup.

2. INSTALL STEAM LINE a) At the generator: Install a 1/2" male NPT sweat adapter directly into the tank. Install a 1/2" union in the steam line to allow easy disconnection for later servicing. Note : There must be no valves, shut offs or restrictions in the steam line!

b) Run the 1/2" copper steam line from the generator to the steam room. Refer to SECTION 2: MOUNTING THE

STEAM GENERATOR and Diagrams 3a and 3b.

• The steam line must slope to allow condensation to drain into the tank or room.

• There must be no dips in the steam line. Low areas may collect condensation and cause faulty operation or cause hot water to spit into the room. c) The steam line should enter the steam room 18” (460 mm) above the floor or at least 12” (305 mm) above a tub rim or ledge. The steam line outlet should be at least 6” (150 mm) from other steam heads to either side and

12” (305 mm) from walls or other surfaces to either side. See Diagrams 4, 5 and 6.

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 9 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

SECTION 3: PLUMBING INSTRUCTIONS (continued)

Diagram 3a

Diagram 3b

Note : See Diagram 6 for a typical installation. Additional steam heads may be added to any installation to reduce steam noise or to provide more steam dispersion around a large room. For large AX14 steamers, we recommend using 2 steam heads to reduce the noise level while steaming.

Note : if steam vents are too close to other surfaces, the steam may be cooled and the surfaces damaged. d) At the steam room : Drill/prepare a 1-3/8” (35 mm) hole for the DIAGRAM 4 steam line entry. Center the 1/2" copper steam pipe in the hole.

See Diagram 4.

• Terminate the steam line with a 1/2" NPT male adapter.

• Stub the line out into the room 3/8” (9,5 mm) from the finished surface.

• Secure the steam line to a structural member.

3. INSTALL STEAM HEAD INSULATOR : Fill in gap (using 100%

Silicone caulk between steam pipe and finished wall surface at point of entry (see Diagram 4). Apply silicone caulk to the finished wall side of the steam head insulator (see Diagram 5) and screw on hand tight until it is flush with the wall with the opening pointing down. If a hand tight fit does not align with the opening pointing down, use Teflon tape on the steam line threads to adjust the fit.

1-3/8”

(35 mm)

HOLE

3/8”

(9,5 mm)

FROM

WALL

1/2 NPT

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 10 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

SECTION 3: PLUMBING INSTRUCTIONS (continued)

4. INSTALL STEAM HEAD: Slide the steam head on until it rests firmly against the finished wall. Tighten the hex head screw underneath the steam head to secure it in place with the Allen wrench provided. The steam head should be level with its fragrance reservoir at the top. See

Diagrams 4 and 6.

IMPORTANT

All fixture holes must be sealed with 100% silicon caulk to avoid moisture damage within walls . Check all of the standard fixtures in the steam room.

SILICONE

BACK

SIDE

DIAGRAM 5

DIAGRAM 6

12” [305 mm]

6”

[150 mm] i i

18”

[460 mm] minimum

Shown with optional 2 nd steam outlet.

5. INSTALL PRESSURE RELIEF SAFETY VALVE: Install the pressure relief valve into its port on the generator.

Install the safety valve within 6” [150] mm of the generator. Run a 3/4" copper line from the valve to a gravity flow drain. The pressure relief valve outlet must drain in accordance with local and national codes.

AUTODRAIN All generators must have a drain valve installed to DIAGRAM 7 allow draining the tank for cleaning and maintenance. A manual ball valve is supplied. An electronic ball valve is available in the

ADX Autodrain option. When installed, Autodrain automatically rinses and empties the steam tank approximately 1 hour after a steam bath stops. This cleans the tank to reduce problems caused by poor water quality and ensures every steam bath starts with clean, fresh water.

Contact Amerec Technical Support for more information . [email protected]

or 1-425-951-1120 or at 1-800-363-0251

6. INSTALL DRAIN VALVE: Install 3/4" NPT pipe nipple directly into the tank as shown in Diagram 7. Install a 3/4" ball valve or an

Autodrain on the nipple then add another nipple to the outlet of the valve. Add a union to the outlet nipple to allow easy discon-

HEATING ELEMENT

ACCESS

CONDUIT

AUTODRAIN

VALVE OR

3” [76 mm] PIPE

MANUAL VALVE nection during servicing. Run a 3/4" copper line from the union

Diagrams 6 and 8 show the optional Autodrain valve to a gravity flow drain. The drain must be connected in accordance with local and national codes .

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 11 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

SECTION 3: PLUMBING INSTRUCTIONS (continued)

IMPORTANT

All drain lines must run downhill, away from the steam generator! Also see Diagram 3.

DIAGRAM 8

• Do not run the drain uphill.

• Do not drain the safety valve into the steam line!

• Do not drain the safety valve into the steam room!

Draining the tank into the steam room may present a scald hazard or damage the materials used to construct the steam room.

• Do not drain into the steam room!

(CONDUIT NOT SHOWN)

7. CONNECT AUTODRAIN: Connect the autodrain wires through ½ in conduit (provided) and secure the conduit to the chassis hole. Connect the drain wires to the terminal block provided next to the steamer’s ground lug. See diagram 8.

SECTION 4: WIRING INSTRUCTIONS

ALSO SEE ELECTRICAL INFORMATION CHART AND WIRING DIAGRAMS

1. ELECTRICAL ROUGH-IN: Size wire for the generator as required by local or national codes. See the electrical information on page 13 for further information. Use copper wire only. Leave 4 ft (1,2 m) of slack wire at generator location for finish hookup. Connect the generator to a dedicated circuit breaker. A GFI device is usually not required by safety agencies. One may be installed if required by local codes or the owner. A GFI device will tend to nuisance trip due to heater element aging.

a. Route the copper supply wire with appropriate strain relief through the hole marked POWER ENTRY. b. Connect the supply wires to the power terminal block as indicated on the wire diagram for your voltage and phase. This may require moving factory installed jumper. Do not change the steamer’s internal jumpers or wiring. Only the supply wiring side of the terminal blocks require configuration by the installer.

c. Connect the Earth wire to the copper Earth ground lug. d. Cover the supply wires inside the steamer with a protective mesh or similar material to protect them from water valve heating.

2. ELECTRICAL INFORMATION The AX steamers are available in 2 basic versions, one for 208V (intended for

208VAC single and three phase for North American use) and 240V (intended for all other installations. The 240V models are rated at 240VAC and may be used on 208 to 240V single phase Line-to-Line or 208 to 240V~N (Lineto-Neutral) or 208V to 240V three phase Delta without Neutral or for Y-connected three phase 380 to 415V~N3.

All Units are factory wired for single phase installation. The installer may change the input to three phase or three phase with Neutral during initial installation (see the wiring diagrams on page 18).

The National Electrical Code (NEC) limits a steamer’s current to 48 Amps so in some cases, two separate power supplies are required: AX11 & AX14 208V single phase and AX14 240V single phase.

See page 18 for Mains Wiring Details. Note: jumpers shown are supplied with the steamer .

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 12 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

Electrical Information

Model

Rated

VAC Watts

Room Size cu ft Room Size cu m min Max min Max

AX4.5

AX6

AX7.5

AX9

AX11

208

240

415~N3

208

240

415~N3

208

240

415~N3

208

240

415~N3

208

240

4500

6000

7510

7500

9000

11250

11000

60

80

100

150

200

90

150

200

300

400

1.70

2.27

2.83

4.25

2.55

4.25

5.66

8.50

5.66 11.30

Notes :

 All steamers must be on a dedicated branch circuit!

 Use only copper wire rated 600V~ and 75°C minimum

 All models require Earth ground

 All line voltage must be more than 195V~ while the steamer is heating

 Steamers must be connected to a means for disconnecting all supply voltages

 All AX14 and 208V AX11 single phase require two Mains supplies

 We recommend ceilings height be 8 ft (2,4m) max. Higher ceilings may cause sitting area to be uncomfortably cool.

AX14

415~N3

208

240

415~N3

13750

14000

350 550 9.91 15.60

Model

AX4.5

AX6

AX7.5

AX9

AX11

AX14

Rated

VAC

208

240

415~N3

208

240

415~N3

208

240

415~N3

208

240

415~N3

208

240

415~N3

208

240

415~N3

Amps

1 phz Breaker

22

19

30

30

29

25

36

31

43

38

40

40

50

40

60

50

18 & 36 30 & 50

46 60

24 & 42 30 & 60

21 & 38 30 & 60

40

30

20

30

30

15

30

20

15

20

15

15

50

50

30

40

40

20

Amps3 phz

25

22

13

21

18

10

17

14

8

12

11

6

38

34

19

31

26

16

Breaker

 240V models may be used at 208 to 240V.

Operating on voltages lower than 240V will result in reduced wattage . Contact Technical Support for further information.

 Single phase 240V models are designed for North

American 240V line to line Mains voltages (without

Neutral) or 240V~N international voltages.

 Three phase 240V models may be wired during installation for a 240V delta configuration or for a

415V~N3 Y-configuration. Neutral must be supplied for 415V !

 NEC Electrical code restrictions limit Mains current to 48A. Some single-phase models require two separate Mains circuits to remain below 48A by splitting the heating load

 Also refer to the wiring diagrams on pages 17 and 18 for more information on connecting your steamer .

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 13 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

SECTION 5. BATH CONTROLS

1. TEMPERATURE SENSOR CABLE ROUGH-IN (low voltage) It is required that the sensor be mounted in the steam room, but not directly over the steam dispersion head or near the door. The sensor should be located in a wall 6” (150 mm) below the ceiling but no more than 7 ft (2,1M) above the floor. String the sensor cable from the sensor location through 1/2:” (12 mm) holes in the wall studs or ceiling joists to the generator location. Drill a clean

7/8: (22 mm) hole through the steam room wall at the sensor location. Leave 12” (305 mm) of slack at the sensor location. See Diagram 9.

DIAGRAM 9

Note: Do not staple through or damage cable.

Use factory supplied cables only .

INSTALL THE TEMPERATURE SENSOR ASSEMBLY inside the steam room. A 7/8” (22 mm) hole should already be in the steam room wall with the cable ready.

Make sure the sensor is not directly over the steam outlet

SENSOR

CABLE

WALL

SENSOR

TIP MUST

POINT

DOWN head or near the door. The sensor should be located in a wall

6” (150 mm) below the ceiling but no more than 7ft (2,1 m) above the floor.

Carefully connect the sensor cable to the sensor. The cable end should slide into place and lock.

7/8’

22 mm

HOLE

SEAL BACK WITH

SILICONE

Run a light bead of silicone around the back surface of the sensor and slide it into the wall with the metal sensor tube pointed down. Tape the sensor to the wall until the silicone has set-up.

Connect the steam generator end of the cable to the short adapter cable (4-pin modular plug to 2 pin sensor cable jack) and plug the adapter into the NTC jack on the steamer board (located along the top edge of the steamer’s circuit board, at the far left of the 4 black jacks). ( See diagram 10 )

2. CONTROL CABLE ROUGH-IN (low voltage) A 50 ft (15,2 m) 4 wire Cat5 cable is provided for connecting the

PURE 2.0 or ELITE control to the steamer. The PURE 2.0 and ELITE controls may be mounted inside or outside the steam room. String the control cable from the control location through 1/2” (13 mm) holes in the wall studs or ceiling joists to the generator. Note: Do not staple through or damage cable. Use factory supplied cables only .

Run the cable end through a 1” (25,4 mm) hole in the wall at the control mounting location. One PURE 2.0 or ELITE control is required; a second may also be connected. Controls should typically be mounted 5 feet (1,5 m) above the floor outside the steam room or at a height comfortable for viewing inside the room while having a steam bath.

See control mounting section for more information.

3. INSTALL THE ELITE or PURE 2.0 CONTROL inside or outside the steam room using the control cable installed in section 5, step 4. If mounting to a smooth, flat wall, the adhesive pad provided will work well to mount the control and seal the cable hole. The adhesive will stick to the wall quickly so be sure to accurately place and level the control before attaching it to the wall!

Your Elite control comes with a plated trim piece; many finishes are available. These trim pieces also fit the Pure 2.0. Contact Sales or Support for further information. If using a trim piece, slide the plated trim piece over the back of the control before mounting the control. Mounting the control will keep the trim in place.

Recommended: Locate controls 5 ft (1,5 m) above floor outside the steam room. Controls mounted inside the room should be set to a height comfortable for use while having a steam bath.

FLOOR

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 14 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

SECTION 5. BATH CONTROLS (continued)

If the surface is uneven or has grout lines, we recommend using a small amount of silicone to mount the control. If using silicone, run a bead around the control’s cable end and another bead around the back of the control as shown here. Then tape in place on the wall until the silicone has set up. Note: and mount in the same manner.

If using the adhesive pad, it will stick to the wall quickly so be sure to accurately place and level the control before attaching it to the wall!

Be sure to carefully level the control while mounting !

Note the Elite and Pure 2.0 controls have the same case :

• The control’s cable end is at the bottom of the control and a cut mark on the back indicates the top of the control!

ADHESIVE

OR

• The Pure 2.0

’s orientation can also be seen by viewing the glass: all the white markings are on the bottom half of the glass.

4. CONNECT THE CONTROL CABLE TO THE STEAMER with the Mains voltage turned off. The control cable should be plugged into the one of the four jacks in the middle of the steamer circuit board (see Diagram 10 and the low voltage wiring diagram on page 17).

SILICONE

DIAGRAM 10

CONNECT TEMPERATURE SENSOR TO JACK AT THE

LEFT SIDE ALONG THE TOP OF THE CIRCUIT BOARD

CONNECT CONTROLS TO ANY OF THE 4 JACKS

IN THE CENTER OF THE CIRCUIT BOARD.

CONFIGURATION SWITCH

AX STEAMER – RIGHT HAND END

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 15 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

SECTION 6. INITIAL START

1. Before turning on power to the generator, make sure the configuration switch is set correctly (see Diagram 10) .

PUSH UP

(ON)

(OFF)

PUSH DOWN

1 2 3 4 5 6 a) If the generator has an electronic AutoDrain installed: If the generator will use an electronic AutoDrain, verify the switch in the middle of the right-hand circuit board is set as shown at left (#2 and #5 down, all other up. b) If the generator has only a manual drain installed: If the generator will not use an electronic AutoDrain, verify the switch in the middle of the right hand circuit board is set as shown at left (#2, #4 and #6 down, all other up.

NOTE: POSITION 2

SHOULD ALWAYS

BE DOWN

1 2 3 4 5 6

2. Make sure the water is turned on, the drain valve is closed and the control(s) and temperature sensor are plugged in, then turn on the line voltage to power the generator.

• Green LEDs will light on the generator’s circuit boards right away then one more will light a few seconds later.

• If the PURE 2.0 is connected : 4 LEDs across the top of the control will begin blinking.

• If the ELITE is connected : About 30 seconds after turning on power, the ELITE screen will light and the amerec logo will show at the bottom of the screen. A few seconds later, the ELITE screen will change to a slowly spinning circle while it loads its program.

• A few seconds after the ELITE stops showing amerec, the PURE 2.0 (if connected) control’s LEDs will start blinking and changing until it stops with the thermometer symbol lit (lower left corner) and one of the 1 –

10 LEDs will be lit. o If an ELITE is not connected, go to step 3a at this point. o If other LEDs are lit or blinking, refer to the PURE 2.0 User’s guide and contact Technical Support if needed .

• The ELITE spinning wheel continues for about 1:30 minutes then begins normal operation. During this time, a red LED will light on the steamer board showing that the control and circuit board are “talking” to each other. o Go to step 3b

3a. If only an PURE 2.0 is connected : If the PURE 2.0 has started properly, press the on/off key and the bath on LED will light and one of the 1 – 10 LEDs will light indicating the current temperature. The generator will fill with water and start heating the room. Press the on/off key again and the generator will stop heating.

3b If an ELITE is connected : If the ELITE has started properly and if it has not been used before, it should guide you through the initial set-up: select the language to use, set region to North America, set the current time and time format and set the current date and date format. Then you will return to the starting menu screen. Next, go to the

Tools menu and a) Choose Units and set to display temperature in Celsius or Fahrenheit b) Choose Bath Temperature to set the maximum bath temp. allowed c) Choose Facility Type and set it to Private for normal home use. This allows a bath time of up to one hour. For spas and other installations where the steam room needs to be kept hot for longer periods, set the facility to Public for up to a 24 hour maximum bath time. d) Next go to the home screen and the display should show the current temperature Press the l key (in the upper right corner) and the key should turn green. The generator will fill with water and start heating the room. Press the 0 key (in the top left corner) and the key should turn red and the generator will stop heating. e) If the generator has an electronic AutoDrain installed : The generator will go through a drain cycle one hour after the bath has been turned off.

For assistance, contact

P.O. Box 2258, Woodinville, WA 98072

Phone 1-800-363-0251

1-425-951-1120

Fax 1-425-951-1130 eMail [email protected]

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 16 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

INSTALLATION CONFIGURATION

Before turning on the liine voltage to the steame r, make sure the steamer circuit board ’s switches are set correctly for the installation.

Switch 1: Is this a single steamer installation or a steamer in a ganged system?

Slide switch 1 up if this is a single steamer or the Primary unit in a ganged system

Slide switch 1 down if this is a second or third steamer in a ganged system

Switches 2-6: Is there an electronic Autodrain valve installed?

Slide switches 2 & 5 down and 3, 4 & 6 up if Autodrain is installed

Slide switches 2, 4 & 6 down and 3 & 5 up if Autodrain is not installed

(Requires manually draining and cleaning the tank periodically)

PUSH UP

(ON)

(OFF)

PUSH DOWN

NOTE: POSITION 2

SHOULD ALWAYS

BE DOWN

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 17 of 18

AX INSTALLATION AND SERVICE INSTRUCTIONS

Model

AX4.5

WATTS

208V

4500

Model

AX4.5

AMPS 1 PhZ

208V

22

Model

AX4.5

AMPS 3 PhZ

208V

12

AX6

AX7.5

6000

7510

AX6

AX7.5

29

36

AX6

AX7.5

17

21

AX9 9000 AX9 43 AX9 25

AX11 11250 AX11 18 & 36 See Note (2) AX11 31

AX14 13750 AX14 24 & 42 See Note (2)

AX14 38

208V 1 phz

AX4.5, AX6,

AX7.5 & AX9

North America

208V 1 phz

AX11 and AX14

(use 2 Circuits)

North America

2 3

L1

4 5 6 7

L2

8 9

Notes:

(1) Use only copper wire rated 75°C or better

(2) AX11 and AX14 single phase requires two feed circuits.

Circuit 1 drives one element and the controls and is the lower amperage circuit.

Circuit 2 drives two elements and is the higher amperage circuit.

See Note (2)

CIRCUIT 2

208V L1 208V L2

CIRCUIT 1

208V L1 208V L2

208V 3 phz

AX4.5 to AX14

North America 2 3 4 5 6 7 8 9 i

208V Models

L1 L2 L3

240V Models

Model

AX4.5

AX6

AX7.5

AX9

AX11

AX14

WATTS

240V / 415V~N3

4500

6000

7500

9000

11000

14000

Notes:

(1) Use only copper wire rated 75°C or better

(2) AX14 single phase requires two feed circuits.

Circuit 1 drives one element and the controls and is the lower amp circuit.

Circuit 2 drives two elements and is the higher amp circuit.

Model

AX4.5

AX6

AX7.5

AX9

AX11

AX14

AMPS 1 Phase

240V

19

25

31

38

46

21 & 38

See Note (2)

208 to 240V 1 phz

AX4.5, AX6, AX7.5,

AX9 & AX11

240V Models

North America

220 to 240V~N

AX4.5, AX6, AX7.5

,

AX9 & AX11

240V Models

International

Model

AX4.5

AX6

AX7.5

AX9

AX11

AX14

AMPS 3 Phase

240V 415V~N3

11

14

6

8

18

22

26

34

10

13

16

19

4 i

L1 L2

220-240V NEUTRAL

208 to 240V 1 phz

AX14 ( use 2-Circuits )

220 to 240V~N

AX14 ( use 2-Circuits )

2 3 4 5 6 7 8 9

2 3 4 5 6 7 8 9

CIRCUIT 2

240V L1 240V L2

CIRCUIT 1

240V L1 240V L2

CIRCUIT 2

220-240V NEUTRAL

CIRCUIT 1

220-240V NEUTRAL

See Note (2)

208 to 240V 3 phz

AX4.5 to AX14

240V Models

North America

2 3 4 5 6 7 8 9

See Note (2)

380 to 415V~3N

AX4.5 to AX14

240V Models

International

2 3 4 5 6 7 8 9

L1 L2 L3 L1 L2 NEUTRAL L3

4211-119 09/18/20 Technical Support 1-425-951-1120 1-800-363-0251 [email protected] Page 18 of 18

APPENDIX: AX SYSTEM INSTALLATION

WARNING

PRIMARY

STEAMER

SECONDARY

STEAMER

SECONDARY

STEAMER

AMEREC STEAMBATH GENERATORS

OR USE WITH STEAM SYSTEMS INCORPORATING

ONE AX PRIMARY STEAM GENERATOR AND

ONE OR TWO AX SECONDARY STEAM GENERATOR(S)

These instructions apply to the

AX4.5, AX6, AX7.5, AX9, AX11 and AX14

Save these instructions! Read all instructions carefully before installation .

These instructions supplement the AX steamer installation instructions,

Amerec document number 4211-119

SECTION 1: GENERAL INFORMATION

Amerec Steam Generators are listed by ETL. The steamers come assembled and ready for installation. Check that the size and rating of the steamers are suitable for your application; refer to Steam Room Construction and

Generator Sizing Guide (Amerec document 4211-36).

Amerec AX Steam Systems consist of one AX steamer acting as a “primary” steamer which may control one or two other AX steamers. The sole purpose of ganging steamers is to increase the volume of steam generated without using multiple controls. The primary steamer controls the secondary steamer(s) through an Amerec control cable. Cables are available only from Amerec.

All controls must connect only to the primary steamer! An Elite control must be connected to the primary steamer!

IMPORTANT

An exhaust fan installed outside the steam room is strongly recommended to remove excess steam from the bathroom or shower area.

MOUNTING

The Amerec Steam Generator can be hung on a wall or set on its base. The best mounting location will satisfy all or most of the following conditions:

1.

The steam line should slope to allow condensation to drain into the steam room.

2.

The steam line should be less than 20 ft (6m) long; 10 ft (3m) is preferred. Steam lines over 20 ft (6m) long should be insulated.

3.

The mounting location should minimize the number of bends and elbows in the steam line.

4.

The steam line should enter the room 18” (460 mm) above the floor or at least 12” (305 mm)above a tub rim or ledge .

Electrical grounding is required on all Steam Generators.

All electrical supplies should be disconnected when servicing a

Steam Generator.

All wiring must be installed by a licensed electrical contractor in accordance with local and national codes.

All plumbing must be installed by a licensed plumber in accordance with all applicable local and national codes.

Steamers are for indoor use only.

Steamers are not for space-heating purposes.

Be certain that steam bath enclosures are properly sealed to avoid water damage from escaping steam. It is recommended that 100% silicone caulk be used to seal all pipes and fittings. Steam must be prevented from escaping into the wall cavity.

Never shut off the water to an appliance that is in use.

Electric Shock Hazard

High Voltage exists within this equipment.

There are no user serviceable parts in this equipment.

05-21-07

4110-79

NOTE: For additional safety instructions, see owner's manual.

4211-119 09/18/20 Technical support: 1-425-951-1120 1-800-363-0251 [email protected]

Page 1

APPENDIX: AX SYSTEM INSTALLATION

WARNING IMPORTANT

! Do not put a shut-off valve in the steam line!

The line must be unrestricted from the steamer into the steam room!

To reduce the risk of explosion, do not interconnect steam outlets!

Before deciding on a mounting location, please read through these installation instructions completely and take a careful look at all of the diagrams.

• Do not mount outdoors.

• Protect from freezing.

• Unit must be located so as to allow access for service.

• The steam steamer will not operate properly unless it is mounted level with the arrows pointed up.

• A separate line must be provided or each steam outlet.

• Avoid traps and valleys where water could collect and cause a steam blockage.|

• The hot steam must be insulated against user contact. Install the steam head so as to avoid potential user contact.

• Do not install the steam head near benches or where condensation will drip on the user or puddle as this will present a scald hazard.

• The pressure relief valve must be installed in manner that reduces the risk of scalding.

• Do Not drain the pressure valve or steamer into the steam room!

• Draining the pressure relief valve into the steam room may present a scald hazard!

An exhaust fan installed outside the steam room is strongly recommended in order to remove excess steam from the steambath or shower area

It is strongly recommended that no exhaust fan be installed inside the steam room. Doing so will result in a loss of heat and steam through the exhaust fan and port.

Insulate all steam lines and drain lines within the enclosed space.

Each steamer must be provided with at least six (6) inches for wiring access at the control wiring end.

Each steamer must be provided with at least 15 inches (380mm) clearance at the pipe end.

LOCATION

5.

No steam head shall be more than 30 inches (760 mm) above the floor.

6.

The steam outlet should be located to avoid potential user contact.

7.

The steamers should be installed in a dry, well ventilated area. The space provided should be at least:

7 cu ft (0,2 m 3 ) for one steamer or 17 cu ft (0,5 m 3 ) for two steamers or 27 cu ft (0,8 m 3 ) for three.

There should be at least 36 inches (900mm) in front of the louvered cover at

Suggested locations are under a vanity or in a closet, attic, crawl space or basement. Note: The steamer must be in an area protected from freezing .

8.

The primary steamer should be installed within a 50 ft (15,2 m) cable length of the controls and temperature sensor and the secondary steamer(s) should be within a 12 ft (3,7 m) cable length of the primary steamer.

each steamer for service access.

Note: S ystem cables and longer control cables are available; contact Technical Support at 1-425-951-1120 or 1 -800-363-0251 or [email protected] for assistance. The installation should provide clearance for service and element removal. See diagram 1.

10.

The mounting location should allow for a drain hookup. There should be no more than three 90° bends and 10 ft (3 m) of pipe between any steamer’s drain outlet and its drain valve inlet. See diagram 4.

11.

Refer to the mounting instructions in Amerec AX installation instructions document 4211-119 for details regarding mounting individual steamers.

Refer to the following diagrams for some suggested systems (and some not allowable steam pipings).

DIAGRAM 1: SERVICE CLEARANCE

6” (150 mm) MIN

SERVICE CLEARANCE

36” (0,9 m) MIN

SERVICE CLEARANCE

15” (380 mm)

SERVICE CLEARANCE

MINIMUM

6” (150 mm) MIN

SERVICE CLEARANCE

4211-119 09/18/20 Technical support: 1-425-951-1120 1-800-363-0251 [email protected]

Page 2

DIAGRAM 2

APPENDIX: AX SYSTEM INSTALLATION

DIAGRAM 3: WATER LINES

SHOWN WITH

OPTIONAL FILTER

(NOT PROVIDED)

PREFERRED INSTALLATION

PREFERRED

DIAGRAM 4: SOME TYPICAL DRAIN LINES

DIAGRAM 5: TYPICAL STEAM LINES

IMPORTANT

• Input water pressure must be 20-100 psi (138-689 kPa)

• If the generators are mounted in a place difficult for the home owner to access, the water supply shut-off valve should be located where it can be quickly accessed in an emergency.

• Do not use a saddle valve or saddle fitting for the water shut-off valve.

• Flush water supply line before final hookup.

4211-119 09/18/20 Technical support: 1-425-951-1120 1-800-363-0251 [email protected]

Page 3

APPENDIX: AX SYSTEM INSTALLATION

DIAGRAM 6a: ACCEPTABLE

DIAGRAM 6b: NOT ACCEPTABLE

SECTION 4: PLUMBING THE GENERATORS (continued)

All plumbing shall be installed by a licensed plumber and conform with local and national codes.

Refer to the plumbing instructions in the individual installation instructions document 4211-119 for details regarding plumbing of the individual steamers in your system.

INSTALL THE PRESSURE RELIEF VALVE

Each steamer must have its own pressure safety valve, 10psi (69 kPa). Connect the input of the pressure relief valve into its port on the steamer. The valve must be within 6” (150 mm) of the steam tank. Run a 3/4” copper pipe from the valve to an appropriate drain.

Do not connect the valve’s outlet to the generator’s drain line! Do not connect the valve’s outlet to the steam line!

4211-119 09/18/20 Technical support: 1-425-951-1120 1-800-363-0251 [email protected]

Page 4

APPENDIX: AX SYSTEM INSTALLATION

DIAGRAM 8: LOCATING THE STEAM HEADS

6” MIN

(150 mm)

12” MIN

(305 mm)

12” MIN

(305 mm)

IMPORTANT

The steam pipe entry into the steam room and the steam head must be caulked to avoid damage caused by steam leakage into the wall.

12” MIN

(305 mm)

12” MIN

(305 mm)

Centering the steam pipe is critical through walls made of plastic, acrylic, resin, fiberglass, or similar materials.

Allowing the pipe to touch materials not rated for 212°F (100°C) or higher will result in damage to these materials.

18” MIN

(46 mm)

18” MIN

(46 mm)

If the steam line is in an area where the temperature will be below 40°F (4°C) or if the line is more than 20 feet (6 m) long, insulate the steam line for best results.

WIRING

1. ELECTRICAL ROUGH-IN

Use correct size and type of power wires and circuit breakers to meet electrical codes. Leave 4 feet (1,2 m) of slack wire at generator location to finish hookup.

Connect each generator to a dedicated circuit breaker.

2 ELECTRICAL FINISH

At the generator, route the copper supply wire with an appropriate strain relief through the hole marked POWER ENTRY. Connect the supply wires to the power terminal block. Refer to the wiring diagrams to determine your connection points and the necessary jumper connection. Connections can be varied to use either single phase or 3 phase or 3 phase +Neutral. Connect the earth ground to the ground lug (green screw).

Notes :

• Two power circuits are required for 208V AX11s and for 208V and 240V AX14s.

• Supply voltage must be 200V or higher. 240V models may be used with available voltages to 240V (and 380V-415V~3N).

• Use copper power wire only! All wire is to be UL Listed, 300V 75°C minimum unless otherwise specified.

• A GFI device is not required by UL or NEC. One may be installed if required by local codes or the owner.

A GFI device will tend to nuisance trip due to heater element aging.

3.

CONNECT STEAMERS TOGETHER a) Connect an AX Systems cable from one of the Primary steamer’s control jacks to one of the secondary steamer’s control jacks. Repeat for the third steamer, if installed. Do Not use an Elite or Pure 2.0 control cable - a special 12 ft (3,7 m) cable is required from Amerec. Note: We recommend system steamers be of similar wattages and, if not the same, the largest wattage should be in the primary steamer. See diagram below.

DIAGRAM 9: CONNECTING STEAMERS

PRIMARY STEAMER f c g

4211-119 07/18/17 f c l m g f c l m g

SECONDARY STEAMER SECONDARY STEAMER

Technical support: 1-425-951-1120 1-800-363-0251 [email protected]

Page 5

APPENDIX: AX SYSTEM INSTALLATION

SECTION 5: WIRING INSTRUCTIONS (continued)

Note: There are 4 control jacks in the center of the steamer board at the right end. Any Elite or Pure 2.0 control or secondary steamer may be connected to any of these 4 jacks. A maximum of 4 devices may be connected to the board.

Note : An Elite control is required with a ganged system!

! Boards and controls may be damaged if connected to any of the other jacks (along the top edge of the board).

! Use only Amerec’s AX Systems cable to connect steamers together. Do Not use control cables -- use of control cables may damage the steamer boards .

3.

b) The switch on the primary steamer’s circuit board should have position 1 up. Reset the switches on the secondary steamers so position 1 is down.

PRIMARY

STEAMER

SECONDARY

STEAMER

PUSH UP

(ON)

WITH

AUTODRAIN

PUSH DOWN

(OFF)

NOTE: POSITION 2

SHOULD ALWAYS

BE DOWN

WITH

MANUAL DRAIN

4.

CONNECT CONTROLS

Connect controls only to the Primary steamer. Refer to the individual steamer instructions for requirements.

SECTION 6: OPERATIONAL TEST After controls and system generators are connected

Refer to Section 6 of the single steamer installation instructions and start the system steamers.

When the Pure 2.0 or Elite control is used to start a steam bath, all steamers in the system will start together and turn their heating elements on and off at the same time while there is enough water in their tanks.

Each steamer will control its own water level during the bath.

If AutoDrain is installed: Each steamer will control its own drain and drain one hour after the bath stops.

! Do Not connect steamer drains together.

! Do Not connect steam outlets from different steamers to the same steam piping.

THE SYSTEM IS NOW READY FOR OPERATION.

4211-119 08/21/19 Technical support: 1-425-951-1120 1-800-363-0251

Technical Support

PO Box 2258

Woodinville, WA 98072

Phone 1-800-363-0251

FAX 425-951-1130 email: [email protected]

[email protected]

Page 6

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • High-power output for large steam rooms and commercial use
  • Single or three-phase power configuration for electrical flexibility
  • Intertek-ETL Laboratory tested for safety and reliability
  • Automatic drain for easy maintenance
  • Compact design for space-saving installation
  • Advanced controls for precise temperature and steam output
  • Durable construction for long-lasting performance

Related manuals

Frequently Answers and Questions

Is the Amerec AX Generator suitable for commercial use?
Yes, the Amerec AX Generator can be used for light commercial applications. However, it is recommended to check with local inspectors to confirm its acceptability for commercial use in specific jurisdictions.
Can the Amerec AX Generator be installed outdoors?
No, the Amerec AX Generator is designed for indoor use only and should be protected from freezing.
What type of electrical connection is required for the Amerec AX Generator?
The Amerec AX Generator can be configured for either single-phase or three-phase power during installation, providing flexibility in electrical connections.