Comelit 3070S, Vandalcom series Technical Manual
Add to my manuals
24 Pages
Comelit 3070S is a digital call module that offers advanced features for managing audio and video communication systems. With a 32-character numeric display and a backlit keypad, it allows users to make calls, control door access, and receive messages. The device supports up to 1000 directory entries, enabling users to quickly and easily connect with other units in the system. Additionally, it offers customizable parameters for door lock time, audio time, and reset time, providing flexibility for different scenarios.
advertisement
EN
TECHNICAL
MANUAL
Digital call module
Art. 3070S
Passion.Technology.Design.
Warning
Intended use
This Comelit product was designed for use in the creation of audio and video communication systems in residential, commercial or industrial settings and in public buildings or buildings used by the public.
Installation
All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
Wires
Cut off the power supply before carrying out any maintenance procedures.
Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
We advise against running the system wires through the same duct as the power cables (230V or higher).
Safe usage
To ensure Comelit products are used safely:
• carefully observe the indications provided in the Manuals / Instruction sheets
• make sure the system created using Comelit products has not been tampered with / damaged.
Maintenance
Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the Manuals / Instruction sheets.
Any repair work must be carried out
• for the products themselves, exclusively by Comelit Group S.p.A
.,
• for systems, by qualified technical personnel.
Disclaimer
Comelit Group S.p.A.
does not assume any responsibility for
• any usage other than the intended use
• non-observance of the indications and warnings contained in this Manual / Instruction sheet.
Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this Manual / Instruction sheet at any time and without prior notice.
2
Table of contents
Technical features ........................................................................... 4
Connections ..................................................................................... 5
Connection to earth of 3070S .................................................................5
Connection to computer .........................................................................5
Connection in Building Kit and SB2 systems ........................................6
Connection in SBTOP and SB1 systems ...............................................6
Program and Operation .................................................................. 7
Call mode testing ................................................................................8
Setting the language ...........................................................................9
Using the digital module ..........................................................................9
Ending a call/conversation................................................................10
Opening the door by entering the password code ...........................10
Accessing/exiting the configuration stage ..........................................11
1.1. System parameters ....................................................................12
1.1.1. Speaker parameters ........................................................12
1.1.2. Download type [NO VIP] .................................................13
1.1.3. Call mode ........................................................................14
1.1.4. RS485 address [NO VIP] ................................................16
1.2. Language ...................................................................................16
1.3. Default settings ..........................................................................17
2.1. Supercode .................................................................................18
2.1.1. Change ............................................................................18
2.1.2. Default settings ................................................................18
2.2. Password ...................................................................................19
2.2.1. Enter ................................................................................19
2.2.2. Delete ..............................................................................19
2.2.3. Delete all .........................................................................20
Data management using 1249B [NO VIP] ............................................21
Entering a list (download)..................................................................21
Reading (upload) of the stored list ....................................................21
System performance and layouts ................................................ 23
Description
Vandalcom series digital call module made using double 2.5 mm 316 stainless steel plate, complete with 12-button backlit keypad plus 16-character alphanumerical display for showing call codes and interactive user messages (engaged, etc.). Also functions as an electronic key code device with a possible 1000 different 6-digit codes. For use in Building kit, SBTOP, SB1 audio, SB2 audio and ViP systems.
2.
1.
MR1
MR2
1.
LCD screen
Terminal block for MR1 connection
V+ V- DC power supply
12~ 12~ AC power supply
S serial port
- reference negative
PR programming input
- reference negative
Terminal block for MR2 connection
D+ RS485 connection
D- RS485 connection
- reference negative
RX RS232 connection
TX RS232 connection
3
4
Technical features
MAIN FEATURES
Backlighting color
Vandal Resistant rating (IK code)
Product height (mm)
Product width (mm)
Product depth (mm)
Operating temperature (°C)
Maximum current absorption (mA)
SOFTWARE/FIRMWARE SPECIFICATIONS
No. user codes
FUNCTIONS
Key button function
HARDWARE SPECIFICATIONS
Total buttons
COMPATIBILITY
Simplebus Top audio/video system
Building Kit audio/video system
Simplebus 2 audio system
Simplebus 1 audio system
Vip system
MOUNTING/INSTALLATION
Flush-mounted
Wall-mounted
AUDIO/VIDEO FEATURES
Display resolution (H x V)
CONNECTIVITY
Type of connections/ports
RS232 ports
RS485 ports
Green led
Yes
106
106
56
-25 ÷ +55
100
1000
Yes
12
Yes
Yes
Yes
Yes
Yes
Yes
Yes
16x2 characters
RS232, RS485
1
1
Connections
Connection to earth of 3070S
To prevent any interference caused by electrostatic discharges, it is advisable to screen the casing as shown in the diagram
Connection to computer
COMPUTER
MOXA
TCC-80
20022618
G
N
D
-
ON
123
USB
ALIM.
5V
Braided, shielded telephone cable
1195
0 3
0
2
4
1
2 0
S P
R
R
X
T
X
3070S
3072S
1195
0
2
0
2
4
1
2
0 S P
R
R
X
T
X
3070S
3072S
It is possible to use up to 5 terminals Art. 3070S-3072S
Maximum distance between l’Art. 20022618 and furthest terminal Art. 3070S-3072S: 100m
D
D120E
1/4W
3070S
3072S
5
Connection in Building Kit and SB2 systems
1210
-
+
1595
120-230 V
SE
-
SE
+
C
O
M
NC NO
J9 J11
G
N
D
D
O
R
T
E
V
-
V
+
L L
4681
1621VC
1621
J1
J2
"V-" BLUE
"S" YELLOW
"V+" BROWN
2E7T000696
V
+
S
-
P
R
D
+
-
R
X
T
X
3070S
V
+
Use the cable 2E7T000696 supplied with Art. 3070S and Art. 3072S
Local lock-release button.
Connection in SBTOP and SB1 systems
-
+
1595
VIDEO ENTRY SYSTEM RISER
120-230 V
S
-
P
R
D
+
-
R
X
T
X
3072S
S
E
C
O
M
NC NO
G
N
D
P
R
D
O
R
T
E
4680C
1622VC
1622VCF
1622
J1
J2
V
+
L L
S P
R
-
"V-" BLUE
"S" YELLOW
"V+" BROWN
2E7T000696
Use the cable 2E7T000696 supplied with Art. 3070S and Art. 3072S.
Local lock-release button.
R
X
T
X
3070S
S P
R
R
X
T
X
3072S
6
Program and Operation
The Comelit digital call module Art. 3070S can be used in Building kit, SBTOP, SB1 audio, SB2 audio and ViP systems, and is fitted with a numeric keypad to call door-entry phone users by entering the code which identifies them.
The main characteristics are as follows:
• Memory capacity for Simplebus systems: 1000 directory entries of 16 numeric characters.
• 32-character numeric display.
• Option of changing the parameters: Door lock time, Audio time and Reset time for the speaker module (reset time adjustment is not available in VIP mode).
• ACCESS CONTROL function for opening the door by keying in a pre-recorded password code.
• 5 call management modes (see
• Standard Simplebus (default),
• Simplebus Indirect code,
• Simplebus Top,
• Simplebus Top Indirect code.
• VIP
• Entering the list of users (Download) via connection to PC equipped with software Art. 1249B.
• Entering the list of users via connection with the PC can be performed over an RS232 line or over an RS485 line by means
of the interface card Art. 20022618 (see “Connection to computer” ).
• Reading (Upload) the list of users stored on the directory module via connection to PC equipped with software Art. 1249B.
• Option of displaying graphics interface messages in one of 12 available languages (Italian, English, French, German,
Portuguese, Danish, Finnish, Dutch, Spanish, Swedish, Polish and Norwegian).
• Welcome message management (only available in VIP mode and programmable via VIP Manager) [NOT SIMPLEBUS, NOT
SIMPLEBUS TOP]
• Screensaver (only available in VIP mode and programmable via VIP Manager) [NOT SIMPLEBUS, NOT SIMPLEBUS TOP]
Navigation mode
DELETE/CANCEL
BACK: exit sub-menu
CALL – DOOR LOCK – MENU SELECTION
√ Access to the configuration stage has been carried out (see
“Accessing/exiting the configuration stage” ).
» The menus are scrolled through automatically every 2 seconds.
f Press to confirm the selection.
f Press to return to the menu level above.
EXAMPLE: Accessing “language” parameter modification f access configuration mode (see
“Accessing/exiting the configuration stage”z
).
MAIN
SETTINGS SETTINGS
SYSTEM PARAM
2 sec
SETTINGS
LANGUAGE
LANGUAGE
DEFAULT
7
A new parameter is entered by scrolling through the possible values using the number keys.
1. Press the number corresponding to the desired value (in the example 0 = Italian).
» after 2 sec. the parameter corresponding to the entered number appears on screen.
2. Press to confirm the parameter. f Press another number to change your selection.
f Press to return to the menu level above.
EXAMPLE: “italiano” selected as language
LANGUAGE
DEFAULT
0
LANGUAGE
_ _ _ 0
LANGUAGE
ITALIANO
2 sec
PARAMETER
CHANGED
Self-testing
Call mode testing
When the device is switched on, it performs a test to check the type of system configured on the speaker (Simplebus,
Simplebus Top or VIP).
If the digital call module is new (or if the parameters have been restored to the default values):
• if the module is connected to a VIP system
» the module aligns with the speaker, self-configuring in “VIP call mode”, and receives all the information and data stored on the speaker;
• if the module is connected to an SB TOP system
» he first call mode display screen shows the string ERROR .
• if the module is connected to an SB system
» the first call mode display screen shows the string SIMPLEBUS.
If the digital call module has a directory already containing data:
• if the directory and speaker are configured differently:
» he first call mode display screen shows the string ERROR .
• if the directory and speaker are aligned:
» the first checking screen will show the system type SB / SB TOP / VIP.
Follow the procedure described in “1.1.3. CALL MODE” if you want to align the directory module with the type of system configured on the speaker.
Module powered up
INITIAL CONDITION
CALL MODE
PLEASE WAIT
The message PLEASE WAIT indicates selftesting in progress.
CALL MODE
SIMPLEBUS or:
CALL MODE
ERROR
At the end of self-testing the type of system set is displayed (SIMPLEBUS by default).
If the directory and speaker are configured differently.
Follow the procedure described in “1.1.3. CALL MODE” if you want to align the directory module with the type of system configured on the speaker.
8
Setting the language
If the LANGUAGE parameter is set to DEFAULT.
During startup (after call mode testing), you will be asked to select the operating language.
PROCEDURE
Select the operating language by entering the corresponding number:
0 = ITALIANO
1 = ENGLISH
2 = FRANÇAIS
3 = DEUTSCH
4 = PORTUGUES
5 = DANSK
6 = SUOMI
7 = NEDERLANDS
8 = ESPAÑOL
9 = SVENSKA
10 = POLSKI
11 = NORSK
12 = DEFAULT(italian)
INITIAL CONDITION
LANGUAGE
DEFAULT
DISPLAY INFO
LANGUAGE
_ _ _ 1
LANGUAGE
ENGLISH
2 sec
The current value of the parameter appears on screen.
DESCRIPTION
N.B. If the LANGUAGE parameter is set to DEFAULT, you will be asked to set the language again at the next startup.
Press the key to confirm the value of the parameter.
Press to exit the selected language.
PARAMETER
CHANGED or:
If entry is successful.
ERROR
If entry does not fall within the limits.
Using the digital module
Calling a user
Module powered up in standby.
PROCEDURE
Enter code using the numeric keypad on module Art. 3070S.
Press the key to call.
INITIAL CONDITION
ENTER USER CODE
DISPLAY INFO
_ _ 1
PRESS TO CALL
PLEASE WAIT
If the call was successful you will see:
CALL
EFFECTED
If the call was not successful you will see:
CALL
FAILED
Or if the riser is busy you will see:
BUSY
USER
If the call is successful and the user answers you will see:
COMMUNICATING...
DESCRIPTION
EXAMPLE: calling a user with code 1.
9
Ending a call/conversation
PROCEDURE
Press the . key
INITIAL CONDITION
CALL
EFFECTED
Or:
COMMUNICATING...
DISPLAY INFO
END OF
COMMUNICATION
Opening the door by entering the password code
PROCEDURE
Press the key.
Enter the password code. (min. 4 characters).
Press to confirm.
INITIAL CONDITION
ENTER
USER CODE
DISPLAY INFO
PASSWORD: _ _ _ _ _ _
CONFIRM WITH
PASSWORD: _ _ * * * *
CONFIRM WITH
DOOR
OPEN
or:
WRONG
PASSWORD
Call effected.
Conversation in progress.
DESCRIPTION
Standby
DESCRIPTION
To cancel the procedure press the . key
If the password is 4-5 characters long, it will self-complete: the first digits will be zero
(e.g.: 001234 / 012345).
If the password code is already in the memory. The contact on the speaker module will be activated.
If the password code does not exist in the memory.
10
Accessing/exiting the configuration stage
PROCEDURE DISPLAY INFO
MAIN
SETTINGS
DESCRIPTION
The module is in programming mode.
Connect terminal PR to terminal – and power up the module.
Configure the parameters you wish to change...(see “1.1. System parameters” )
The menus are scrolled through automatically every 2 seconds.
After configuration is complete, cut off the power supply and remove the connection between PR and –.
The module has exited programming mode.
Or:
PROCEDURE DISPLAY INFO DISPLAY INFO
In standby.
PASSWORD: _ _ _ _ _ _
CONFIRM WITH
Login screen.
Press .
Enter the supercode (default = 778899).
PASSWORD:
******
If the supercode is 4-5 characters long, it will self-complete: the first digits will be zero
(e.g.: 001234 / 012345).
The module is in programming mode.
Press to confirm.
MAIN
SETTINGS
The menus are scrolled through automatically every 2 seconds.
Configure the parameters you wish to change...(see “1.1. System parameters” )
Wait 30 sec.
The module has exited programming mode.
11
1. Settings
1.1. System parameters
1.1.1. Speaker parameters
This procedure can be used to:
A. Change the audio time audio times (t AUDIO)
B. Change the door lock time the door lock relay closure time (t DOOR LOCK)
C. Change the reset time [NOT VIP] the speaker module reset time once door-entry phone communication has ended (t
RESET)
PROCEDURE DISPLAY INFO DESCRIPTION
Access configuration (see “Accessing/ exiting the configuration stage”
)
Select the menu SETTINGS / SYSTEM
PARAM. / SPEAKER PARAM.
using the key .
SETTINGS
SYSTEM PARAM.
SYSTEM PARAM.
SPEAKER PARAM.
SPEAKER PARAM.
ENTER t AUDIO
The menus are scrolled through automatically every 2 seconds.
Select, using the key the menu option for the parameter you want to change. (t
AUDIO, t DOOR LOCK, t RESET)
To change the parameter, enter a new value.
ENTER t AUDIO
0010
ENTER t AUDIO
_ _ 20
EXAMPLE: Changing the conversation time.
The minimum (not current) value of the parameter appears on screen.
Choose a value that falls within the following limits:
[SB] [SB TOP] t AUDIO (10-180) t DOOR LOCK (1-8) t RESET (1-10)
[VIP] t AUDIO (30-600) t DOOR LOCK (1-60)
Press the key to confirm the value of the parameter.
PARAMETER
CHANGED
or:
If entry is successful.
ERROR
If entry does not fall within the limits.
Exit configuration (see
“Accessing/exiting the configuration stage” )
D. Viewing [NO VIP] This procedure can be used to view the audio time, door lock relay closure time and reset time for the speaker module, plus the call mode.
PROCEDURE DESCRIPTION
Access configuration (see “Accessing/ exiting the configuration stage”
) Select the menu SETTINGS / SYSTEM PARAM. /
SPEAKER PARAM. / using the key .
VIEWING
DISPLAY INFO
SETTINGS
SYSTEM PARAM.
SYSTEM PARAM.
SPEAKER PARAM.
SPEAKER PARAM.
VIEWING
The menus are scrolled through automatically every 2 seconds.
12
AUDIO TIMING
0020
DOOR LOCK TIME
0002
RESET TIME
0010
CALL MODE
SIMPLEBUS
The parameter values are displayed automatically every 2 seconds.
Press o exit speaker parameter viewing.
Exit configuration (see
“Accessing/exiting the configuration stage” )
1.1.2. Download type [NO VIP]
The parameter sets the type of connection (RS232 or RS485) used for data management.
PROCEDURE
Access configuration (see
“Accessing/ exiting the configuration stage”
) Select the menu SETTINGS / SYSTEM PARAM. /
DOWNLOAD TYPE using the key.
DISPLAY INFO
MAIN
SETTINGS
SETTINGS
SYSTEM PARAM.
SYSTEM PARAM.
DOWNLOAD TYPE
DOWNLOAD TYPE
RS232
The currently configured value appears on screen.
DESCRIPTION
The menus are scrolled through automatically every 2 seconds.
Select the download type by entering the corresponding number:
0 = RS232
1 = RS485
DOWNLOAD TYPE
_ _ _ 1
2 sec EXAMPLE: Changing the download type.
Press the key of the parameter.
to confirm the value
DOWNLOAD TYPE
RS485
PARAMETER
CHANGED or:
If entry is successful.
ERROR
If entry does not fall within the limits.
Exit configuration (see “Accessing/exiting the configuration stage” )
13
1.1.3. Call mode
There are 5 call management modes to choose from:
• Standard Simplebus (default),
• Simplebus Indirect code,
• Simplebus Top,
• Simplebus Top Indirect code,
• VIP
A. SIMPLEBUS - STANDARD call mode (default)
In this operating mode, the door-entry phone user is identified by a Code field no longer than 3 digits (between 1 and 240).
The call is made as follows:
1. On the keypad, enter the code 1
2. Press the key
» transmit the call to the user identified with the code 1
B. SIMPLEBUS - INDIRECT CODE call mode
In this operating mode, the door-entry phone user is identified by an Indirect Code field no longer than 6 digits and a
Code field no longer than 3 digits (between 1 and 240).
Example
User identified by Code = 1 and Indirect Code = 1000
The call is made as follows:
1. On the keypad, enter the code 1000
2. press the key
» transmit the call to the user identified with the code 1
C. SIMPLEBUS TOP call mode
In this operating mode, the door-entry phone user is identified by a 2-part Code field; a zone field with up to 3 digits between 1 and 500) and a user field which must have 3 digits (between 1 and 240).
The call is made as follows:
1. On the keypad, enter the code 25 015
2. press the key
» call transmitted to the user identified with the code 25 015
D. SIMPLEBUS TOP – INDIRECT CODE call mode
In this operating mode, the door-entry phone user is identified by an Indirect Code field no longer than 6 digits and a 2-part Code field; a zone field with up to 3 digits between 1 and 500) and a user field which must have 3 digits
(between 1 and 240).
Example
User identified by Code = 25 015 and Indirect Code = 1000
The call is made as follows:
1. On the keypad, enter the code 1000
2. press the key .
» call transmitted to the user identified with the code 25 015
E. VIP call mode
In this operating mode the door-entry phone user is identified with a VIP address (max. 8 digits; for code selfcompletion please refer to the technical manual for VIP Manager software).
Address entry on the speaker is managed using VIP Manager software.
The call is made as follows:
1. On the keypad, enter the code 56
14
2. press the key
» transmit the call to the user identified with the code 56
PROCEDURE
Access configuration (see
“Accessing/ exiting the configuration stage”
)
Select the menu SETTINGS / SYSTEM
PARAM. / CALL MODE using the key.
Select the call mode by entering the corresponding number:
0 = SIMPLEBUS
1 = SIMPLEBUS TOP
2 = VIP
Press the key to confirm the value of the parameter.
Select the call mode by entering the corresponding number:
0 = STANDARD
1 = INDIRECT CODE
[NO VIP]
Press the key to confirm the value of the parameter.
DISPLAY INFO
MAIN
SETTINGS
SETTINGS
SYSTEM PARAM.
SYSTEM PARAM.
CALL MODE
CALL MODE
SIMPLEBUS
CALL MODE
_ _ _ 1
2 sec
CALL MODE
SIMPLEBUS TOP
PLEASE WAIT
CALL MODE
STANDARD
CALL MODE
_ _ _ 1
2 sec
CALL MODE
INDIRECT CODE
PARAMETER
CHANGED or:
ERROR or:
ERROR
DEFAULT SETTINGS
DESCRIPTION
The menus are scrolled through automatically every 2 seconds.
The current value of the parameter appears on screen (Simplebus, Simplebus Top, VIP).
EXAMPLE: setting the system as
SIMPLEBUS TOP
If the change was successful the speaker will emit a confirmation tone.
The current value of the parameter appears on screen (Standard or indirect code).
EXAMPLE: setting the call mode as
INDIRECT CODE.
If entry is successful.
If entry does not fall within the limits.
If the directory and speaker are configured differently and the directory already contains data, the default values must be restored.
Exit configuration (see “Accessing/exiting the configuration stage” )
15
1.1.4. RS485 address [NO VIP]
The value of this parameter is used only in special applications.
PROCEDURE
Access configuration (see
Select the SETTINGS / SYSTEM PARAM. /
ADDRESS RS485 using the key.
DISPLAY INFO
MAIN
SETTINGS
SETTINGS
SYSTEM PARAM.
SYSTEM PARAM.
ADDRESS RS485
ADDRESS RS485
0000
ADDRESS RS485
_ 250
Enter the RS485 address: from 0 to 255.
2 sec
Press the key of the parameter.
to confirm the value
RS485
0250
PARAMETER
CHANGED or:
ERROR
Exit configuration (see “Accessing/exiting the configuration stage” )
The menus are scrolled through automatically every 2 seconds.
The current value of the parameter appears on screen.
EXAMPLE:
DESCRIPTION
Entering address 250.
If entry is successful.
If entry does not fall within the limits.
1.2. Language
The value of this parameter is used to set the language in which messages are displayed.
PROCEDURE
Access configuration (see using the key.
“Accessing/ exiting the configuration stage”
Select the menu SETTINGS /
)
LANGUAGE
DISPLAY INFO
MAIN
SETTINGS
SETTINGS
LANGUAGE
LANGUAGE
ENGLISH
DESCRIPTION
The menus are scrolled through automatically every 2 seconds.
The current value of the parameter appears on screen.
Select the operating language by entering the corresponding number:
0 = ITALIANO / 1 = ENGLISH
2 = FRANÇAIS / 3 = DEUTSCH
4 = PORTUGUES / 5 = DANSK
6 = SUOMI / 7 = NEDERLANDS
8 = ESPAÑOL / 9 = SVENSKA
10 = POLSKI / 11 = NORSK
12 = DEFAULT(italiano)
LANGUAGE
_ _ _ 0
LANGUAGE
ITALIANO
2 sec
EXAMPLE: Setting the language to English.
N.B. If the LANGUAGE parameter is set to DEFAULT, you will be asked to set the language again at the next startup.
Press the key to confirm the value of the parameter.
PARAMETER
CHANGED or:
If entry is successful.
ERROR
If entry does not fall within the limits.
Exit configuration (see “Accessing/exiting the configuration stage” )
16
1.3. Default settings
This procedure restores the factory-set default parameters:
Language = DEFAULT;
System type = SIMPLEBUS;
Call type = STANDARD;
Screensaver =disabled (the Screen Saver function can only be programmed for VIP systems using VIP Manager);
RS485 address = 0000;
Download type = RS232;
Supercode = 778899;
Welcome message = disabled (the Welcome message function can only be programmed for VIP systems using VIP
Manager);
Static welcome message = disabled (the Welcome message function can only be programmed for VIP systems using
VIP Manager);
Number of directory entries = 0
Number of password entries = 0
This procedure resets the directory and password database
PROCEDURE
Access configuration (see
“Accessing/ exiting the configuration stage”
)
Select the menu SETTINGS / DEFAULT
SETTINGS using the key.
DISPLAY INFO
MAIN
SETTINGS
SETTINGS
DEFAULT SETTINGS
DESCRIPTION
The menus are scrolled through automatically every 2 seconds.
The current value of the parameter appears on screen.
Select the desired value by entering the corresponding number:
0 = NO
1 = YES
DEFAULT SETTINGS
_ _ _ 1
2 sec
DEFAULT SETTINGS
YES
PLEASE WAIT
Press the key to confirm the value of the parameter.
Press to exit the menu.
Exit configuration (see “Accessing/exiting the configuration stage” )
PARAMETER
CHANGED
If entry is successful.
17
2. Access control
2.1. Supercode
The supercode can be used to access the configuration menu.
2.1.1. Change
PROCEDURE
Access configuration (see exiting the configuration stage”
Select the menu ACCESS CONTROL /
SUPERCODE /
.
CHANGE
using the key
DISPLAY INFO
MAIN
ACCESS CONTROL
ACCESS CONTROL
SUPERCODE
SUPERCODE
CHANGE
Enter the new supercode value.
SUPERCODE
VALUE: _ _ _ * * *
Press the key to confirm the value of the parameter.
PARAMETER
CHANGED or:
PASSWORD ALREADY
IN MEMORY
Exit configuration (see
“Accessing/ exiting the configuration stage” )
DESCRIPTION
The menus are scrolled through automatically every 2 seconds.
The supercode must be at least 4 digits long.
If the supercode is 4-5 characters long, it will self-complete: the first digits will be zero (e.g.: 001234 / 012345).
If entry is successful.
If the password has already been entered.
2.1.2. Default settings
PROCEDURE
Access configuration (see
“Accessing/ exiting the configuration stage” )
Select the menu ACCESS CONTROL /
SUPERCODE / DEFAULT SETTINGS using the key .
Select the desired value:
0 = NO
1 = YES
Press the key to confirm the value of the parameter.
DISPLAY INFO
ACCESS CONTROL
SUPERCODE
SUPERCODE
DEFAULT SETTINGS
DEFAULT SETTINGS
NO
DEFAULT SETTINGS
_ _ _ 1
2 sec
DEFAULT SETTINGS
YES
PARAMETER
CHANGED or:
ERROR
DESCRIPTION
The menus are scrolled through automatically every 2 seconds.
The current value of the parameter appears on screen.
default = 778899
If entry is successful.
If entry does not fall within the limits.
Exit configuration (see
“Accessing/ exiting the configuration stage” )
18
2.2. Password
The door lock relay on the speaker module can be activated by entering a password code stored previously (see
“Opening the door by entering the password code” )
2.2.1. Enter
PROCEDURE
Access configuration (see “Accessing/ exiting the configuration stage” )
Select the ACCESS CONTROL /
PASSWORD / ENTER using the key .
Enter the desired password code.
Press the key to confirm the value of the parameter.
To exit the menu, press .
DISPLAY INFO
MAIN
ACCESS CONTROL
ACCESS CONTROL
PASSWORD
PASSWORD
ENTER
PASSWORD
VALUE: _ _ _ _ _ _
PASSWORD
VALUE: * * * * * *
PARAMETER
CHANGED or:
PASSWORD ALREADY
IN MEMORY
If entry is successful.
Up to 1000 password codes can be entered.
If the password has already been entered.
DESCRIPTION
The menus are scrolled through automatically every 2 seconds.
The password must be at least 4 digits long. If the password is 4-5 characters long, it will self-complete: the first digits will be zero (e.g.: 001234 / 012345).
Exit configuration (see
“Accessing/ exiting the configuration stage” )
2.2.2. Delete
PROCEDURE
Access configuration (see
“Accessing/ exiting the configuration stage” )
Select the menu ACCESS CONTROL /
PASSWORD / DELETE using the key
Enter the desired password code.
Press the key to confirm deletion.
To exit the menu, press .
Exit configuration (see
“Accessing/ exiting the configuration stage” )
DISPLAY INFO
ACCESS CONTROL
PASSWORD
PASSWORD
DELETE
PASSWORD
VALUE: _ _ _ _ _ _
PASSWORD
VALUE: * * * * * *
PARAMETER
CHANGED or:
WRONG
PASSWORD
DESCRIPTION
The menus are scrolled through automatically every 2 seconds.
Enter the exact password (the first two digits, if omitted, will be entered as zero).
If entry is successful.
If the password is not recognised.
19
2.2.3. Delete all
PROCEDURE
Access configuration (see “Accessing/ exiting the configuration stage” )
Select the menu ACCESS CONTROL /
PASSWORD / DELETE ALL using the key .
Press the key to confirm deletion.
Exit configuration (see
“Accessing/ exiting the configuration stage” )
DISPLAY INFO
ACCESS CONTROL
PASSWORD
PASSWORD
DELETE ALL
DELETE
ALL PASSWORD?
PLEASE WAIT
PARAMETER
CHANGED
DESCRIPTION
The menus are scrolled through automatically every 2 seconds.
Press the key to cancel the procedure.
3. Info
This procedure can be used to view:
• the firmware version
• the number of users stored [NO VIP]
• the number of passwords stored [NO VIP]
• the RS485 address [NO VIP]
• the call mode
PROCEDURE
Access configuration (see
“Accessing/ exiting the configuration stage”
) Select the menu INFO using the key.
DISPLAY INFO
MAIN
INFO
Art. 3070B
1.1
Press the key to exit the menu.
Exit configuration (see “Accessing/exiting the configuration stage” )
DESCRIPTION
The menus are scrolled through automatically every 2 seconds.
20
Data management using 1249B [NO VIP]
Entering a list (download)
Software Art.1249B can be used to enter the list with Indirect Code and Code fields for INDIRECT CODE operating mode on module 3070S. 3070S must be set to indirect code call mode (vedi
Module powered up in standby mode.
PROCEDURE
Connect the cable supplied with software Art.
1249B to terminals TX / RX / - (or D / D- if you have an RS485 line).
INITIAL CONDITION
ENTER
USER CODE
DISPLAY INFO
ENTER
USER CODE
DESCRIPTION
Run software Art. 1249B.
ENTER
USER CODE
On software 1249B with R.I. 003, the
CALL MODE must be set as Indirect Code without a name entry.
Make the list with the Code and Indirect
Code entries in software Art. 1249B, or load an existing list.
Press the Download button in software Art. 1249B.
ENTER
USER CODE
DOWNLOADING...
COMPLETED
Or
DOWNLOADING...
ABORTED
If the download was completed successfully.
If an error occurred during the download.
Reading (upload) of the stored list
Software Art.1249B can be used to read, inside module 3070S, the list with Indirect Code and Code fields for INDIRECT CODE operating mode. 3070S must be set to indirect code call mode (see
).
Module powered up in standby mode.
PROCEDURE
Connect the cable supplied with software
Art. 1249B to terminals TX / RX / - (or D / D- if you have an RS485 line).
INITIAL CONDITION
ENTER
USER CODE
DISPLAY INFO
ENTER
USER CODE
DESCRIPTION
Run software Art. 1249B.
ENTER
USER CODE
Press the Upload button in software Art. 1249B.
UPLOAD
COMPLETED
Or
UPLOAD
ABORTED
If the upload was completed successfully.
If an error occurred during the upload.
21
Navigation tree
MAIN
SETTINGS
SYSTEM PARAM.
[NO VIP]
SPEAKER PARAM.
ENTER t AUDIO
[NO VIP]
ENT. t DOOR LOCK
[NO VIP]
ENTER t RESET
VIEWING
_ _ 30
_ _ _ 3
_ _ _ 2
AUDIO TIMING
DOOR LOCK TIME
RESET TIME
CALL MODE
RANGE SB&SBTOP 10-180
RANGE VIP 30-600
RANGE SB&SBTOP 1-8
RANGE VIP 1-60
RANGE SB&SBTOP 1-10
[NO VIP]
[NO VIP]
[NO VIP]
[NO VIP]
[NO VIP]
DOWNLOAD TYPE
_ _ _ 0
_ _ _ 1
RS232
RS485
CALL MODE
_ _ _ 0
_ _ _ 1
_ _ _ 2
SIMPLEBUS
SIMPLEBUS TOP
VIP
_ _ _ 0
_ _ _ 1
_ _ _ 0
_ _ _ 1
STANDARD
[NO VIP]
[NO VIP]
INDIRECT CODE
STANDARD
[NO VIP]
[NO VIP]
INDIRECT CODE
ADDRESS RS485
_ 250
RANGE SB&SBTOP 0-255
[NO VIP]
LANGUAGE
LANGUAGE
_ _ _ 0
_ _ _ 1
_ _ _ 2
_ _ _ _
_ _ 12
ITALIANO
ENGLISH
FRANCAIS
....
DEFAULT
DEFAULT SETTINGS
_ _ _ 0
_ _ _ 1
YES
NO
ACCESS CONTROL
SUPERCODICE
CHANGE
VALUE: _ _ _ _ _ _
DEFAULT SETTINGS
_ _ _ 0
_ _ _ 1
THE SUPERCODE MUST
CONTAIN AT LEAST 4 DIGITS
YES
NO
PASSWORD
ENTER
DELETE
DELETE ALL
VALUE: _ _ _ _ _ _
THE PASSWORD MUST CONTAIN
AT LEAST 4 DIGITS
VALUE: _ _ _ _ _ _
ENTER THE EXACT PASSWORD
(THE FIRST TWO DIGITS, IF OMITTED,
WILL BE ENTERED AS ZERO)
DELETE ALL PASSWORD?
INFO
ART. 3070B
.....
22
System performance and layouts
For further information of system performance and to view installation layouts, click on the system type that best meets your requirements:
• Building Kit audio/video system for the creation of audio-video systems for small apartment blocks.
• SBTOP audio/video system for the creation of audio-video systems for residential complexes.
• SB2 audio system for the creation of audio systems for residential complexes.
• SB1 audio system for the creation of audio systems for residential complexes.
23
C E R T I F I E D M A N A G E M E N T S Y S T E M S w w w . c o m e l i t g r o u p . c o m
Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy
1ª edizione 07/2018 cod. 2G40002105
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- Vandal-resistant stainless steel body
- 12-button backlit keypad
- 16-character alphanumeric display
- Can store up to 1000 different 6-digit codes
- Easy to install and use
Related manuals
Frequently Answers and Questions
What is the Comelit Vandalcom series digital call module?
What are the benefits of using the Comelit Vandalcom series digital call module?
How do I install the Comelit Vandalcom series digital call module?
advertisement
Table of contents
- 2 Warning
- 3 Description
- 4 Technical features
- 5 Connections
- 5 Connection to earth of 3070S
- 5 Connection to computer
- 6 Connection in Building Kit and SB2 systems
- 6 Connection in SBTOP and SB1 systems
- 7 Program and Operation
- 7 Navigation mode
- 8 Self-testing
- 8 Call mode testing
- 9 Setting the language
- 9 Using the digital module
- 9 Calling a user
- 10 Ending a call/conversation
- 10 Opening the door by entering the password code
- 11 Accessing/exiting the configuration stage
- 12 1. Settings
- 12 1.1. System parameters
- 12 1.1.1. Speaker parameters
- 13 1.1.2. Download type [NO VIP]
- 14 1.1.3. Call mode
- 16 1.1.4. RS485 address [NO VIP]
- 16 1.2. Language
- 17 1.3. Default settings
- 18 2. Access control
- 18 2.1. Supercode
- 18 2.1.1. Change
- 18 2.1.2. Default settings
- 19 2.2. Password
- 19 2.2.1. Enter
- 19 2.2.2. Delete
- 20 2.2.3. Delete all
- 20 3. Info
- 21 Data management using 1249B [NO VIP]
- 21 Entering a list (download)
- 21 Reading (upload) of the stored list
- 22 Navigation tree
- 23 System performance and layouts