Anuncio
Anuncio
PACK SOLO
Standalone Biometric reader
Access control
Technical manual
Technical manual PACKSOLO
– V1.5
Contents
Contents ......................................................................................................................... 2
Warning .......................................................................................................................... 3
Acknowledgement ......................................................................................................... 4
Information and recommendations .............................................................................. 5
Technical characteristics .............................................................................................. 6
1) Biometric reader ...................................................................................................... 6
2) Remote control opening .......................................................................................... 6
Wiring diagram ............................................................................................................... 7
3) Connecting the reader to the control module .......................................................... 7
4) Connecting to a third party intrusion control unit ..................................................... 8
5) Connecting an exit push button and a door contact ................................................ 8
6) Switch configuration ................................................................................................ 9
7) Power failure door activator .................................................................................. 10
8) Electromagnetic door lock triggered by a power failure ......................................... 10
9) Standard door activator: triggered by a voltage pulse ........................................... 11
Initial power-on – Factory configuration .................................................................... 12
Installation of more than one reader on the same site ............................................. 13
User management ........................................................................................................ 14
1) Add a user with a badge plus fingerprint ............................................................... 14
2) Add a user with badge only ................................................................................... 15
3) Add user with a fingerprint only ............................................................................. 15
4) Add an “Alarm” user with a badge and fingerprint ................................................. 16
5) Add an “Alarm” user with fingerprint only .............................................................. 17
6) Deleting a badge ................................................................................................... 17
7) Deleting a user with fingerprint only ...................................................................... 18
8) Deleting all users (fingerprints and badges only) .................................................. 18
Restore to factory settings ......................................................................................... 19
Signaling LEDs ............................................................................................................ 20
Connector blocks ........................................................................................................ 21
Check list ...................................................................................................................... 22
Notes ............................................................................................................................. 23 p.2/24
Warning
Technical manual PACKSOLO
– V1.5
Caution: This product is designed to work only in a standalone mode p.3/24
Technical manual PACKSOLO
– V1.5
Acknowledgement
Dear client,
You have just purchased a “
PACKSOLO
” reader with remote control opening built by the
French company EDEN INNOVATIONS.
The entire EDEN INNOVATIONS team would like to thank you for your interest as well as your confidence in our security solution.
We hope that you will be completely satisfied with the level of security it provides for your com pany’s premises.
Should you have any comments, please contact us via our web site at www.eden-innovations.com
The EDEN INNOVATIONS team. p.4/24
Technical manual PACKSOLO
– V1.5
Information and recommendations
p.5/24
Pursuant to European directive UTE C00-200, incorporating directives 89/336 EEC and
92/31 EEC, PACKSOLO complies with the following standards:
NF EN 50081-1 governing electromagnetic radiation, and
NF EN 50082-1 governing electromagnetic susceptibility.
Cabling recommendations: the cables used to connect readers, the network and other peripherals must be installed in accordance with the instructions for Level 2 (protected environment) of standard NF EN 61000-4-4.
This product must be installed by an approved company.
Incorrect installation and usage may result in electric shock or fire. Before installing the product, read the technical information and comply with the recommendations.
Once the power is turned off, all the internal capacitors will discharge themselves to a safe level after 60 seconds under normal conditions. However, in the event of a power failure, the charge may be maintained for much longer and suitable precautions should be taken before handling the product.
Technical manual PACKSOLO
– V1.5
Technical characteristics
1) Biometric reader
Maximum power consumption ........ 300mA @12V
Power supply voltage ...................... 9
– 14VDC
Weight ............................................. 175 g
Housing dimensions ........................ 119 x 77 x 40 mm
Operating temperature .................... - 20°C to + 50°C
........................................................ - 4°F to +122°F
Fingerprints ..................................... 500 templates
2) Remote control opening
Maximum power consumption ........ 200mA @12V
Power supply voltage ...................... 9 – 14VDC
Weight ............................................. 200g
Housing dimensions ........................ 77 x 55 x 25 mm
Operating temperature .................... - 20°C to + 50°C
........................................................ - 4°F to +122°F
Control relay .................................... 1A / 12V – 1A / 24V
Transistored output ......................... 100mA/active at 0V p.6/24
Technical manual PACKSOLO
– V1.5
Wiring diagram
3) Connecting the reader to the control module
Data sheet:
12 V DC power supply
4 wires (3 pairs recommended)
Ø
1200 m (2730 ft)
0.6 mm (1/30 in) (SYT recommended)
Characteristic: Sensitive connection
Screen: Mandatory
To achieve 1200 m (2730 ft), you need to install a 120
resistor at each end of the network between points A and B (see above).
Note: The total length must not exceed the recommended distance. p.7/24
Technical manual PACKSOLO
– V1.5
4) Connecting to a third party intrusion control unit
Commutator outputs open
Third party intrusion control unit
Input: intrusion trigger
Input: “activation”
Output: “Status of the control unit”
Note: To connect a third party intrusion control unit, ensure that a common earth is connected between the control module and the control unit.
Input: dry contact:
If the input is set to 0V: The alarm is activated
(opening impossible, mandatory inactivation of the alarm before opening, using an alarm fingerprint or manually)
5) Connecting an exit push button and a door contact
Intrusion trigger p.8/24
Press button
Technical manual PACKSOLO
– V1.5
6) Switch configuration
The control module has 3 configuration switches:
Switches 1 and 2: configuration of the time delay for the opening control
Bistable mode
5 seconds
10 seconds
20 seconds
Switch 3: configuration of the “Alarm activation/inactivation” output
(activation/inactivation of a third party intrusion control unit)
Bistable mode
Impulsion 1 second p.9/24
Technical manual PACKSOLO
– V1.5 p.10/24
7) Power failure door activator
Non-return diode
12V 0V
Power supply
Note: In order to avoid any random malfunctions that may interfere with the correct use of the system caused by return currents, it is essential to use and connect the non-return diodes supplied with the product in accordance with the wiring diagram above.
Even when using an additional backed-up power supply for locking, which is separate from the reader's power supply, it is obligatory to follow the wiring diagram above.
8) Electromagnetic door lock triggered by a power failure
Non-return diode
12V 0V
Power supply
Note: In order to avoid any random malfunctions that may interfere with the correct use of the system caused by return currents, it is essential to use and connect the non-return diodes supplied with the product in accordance with the wiring diagram above.
Even when using an additional backed-up power supply for locking, which is separate from the reader's power supply, it is obligatory to follow the wiring diagram above.
Technical manual PACKSOLO
– V1.5 p.11/24
9) Standard door activator: triggered by a voltage pulse
Non-return diode
+12V 0V
Power supply
Note: In order to avoid any random malfunctions that may interfere with the correct use of the system caused by return currents, it is essential to use and connect the non-return diodes supplied with the product in accordance with the wiring diagram above.
Even when using an additional backed-up power supply for locking, which is separate from the reader’s power supply, it is obligatory to follow the wiring diagram above.
Technical manual PACKSOLO
– V1.5 p.12/24
Initial power-on – Factory configuration
When you first start the product, you need to register the 3 configuration cards ( Add , Add Alarm and Delete ) with the reader in order to activate it. To do this, follow the procedure below:
( blue and green LEDs blink alternately) Present the
Add badge
After this stage, your product is activated.
Present the
Add Alarm badge
(
Present the
Delete
Blue
badge
LED blink)
Technical manual PACKSOLO
– V1.5 p.13/24
Installation of more than one reader on the same site
If you use the badge with fingerprint access for several readers on the same site, so as to remember the same code for each reader (therefore to not repeat the addition of badges on each reader), you must only use one set of configuration badges for all readers on the same site.
Reader 1
Reader 2
Reader 3
Technical manual PACKSOLO
– V1.5
User management
1) Add a user with a badge plus fingerprint
Present the Add badge at the same time as the badge for the user you wish to add
You have 10 seconds to present the second finger of the user to be added 3 times (if you only want to enrol one finger, wait for 10 seconds) p.14/24
You have 10 seconds to present the first finger of the user to be added 3 times
Present the badge for the user that you want to add again and wait for the enrolment confirmation BEEP
Technical manual PACKSOLO
– V1.5 p.15/24
2) Add a user with badge only
Present the Add badge at the same time as the badge for the user you want to add
3) Add user with a fingerprint only
Wait 10 seconds Present the badge for the user that you want to add again and wait for the enrolment confirmation BEEP
Present the Add badge You have 10 seconds to present
3 times the first finger of the user to be added
You have 10 seconds to present 3 times the second finger of the user to be added (if you only want to enrol one finger, wait for 10 seconds)
Technical manual PACKSOLO
– V1.5 p.16/24
4) Add an “Alarm” user with a badge and fingerprint
Note: An “Alarm” user can, by presenting his/her second fingerprint, activate or inactivate a third party alarm system.
Present the Add Alarm badge at the same time as the badge for the user you want to add
You have 10 seconds to present the access finger of the user to be added 3 times
You have 10 seconds to present the alarm finger of the user to be added 3 times (if you do not enrol a second fingerprint, the badge added will be encrypted as for a standard user – without an alarm function)
Present the badge for the user that you want to add again and wait for the enrolment confirmation BEEP
Technical manual PACKSOLO
– V1.5
5) Add an “Alarm” user with fingerprint only
Present the badge
6) Deleting a badge
Add Alarm You have 10 seconds to present the access finger of the user to be added 3 times
You have 10 seconds to present the alarm finger of the user to be added
3 times (if you do not enrol a second fingerprint, the user added will not have an alarm function)
Present the Delete p.17/24
badge at the same time as the badge for the user you want to delete then wait for the confirmation BEEP
Technical manual PACKSOLO
– V1.5
7) Deleting a user with fingerprint only p.18/24
Present the badge
Delete
You have 10 seconds to present one of the 2 fingers of the user to be deleted. If the user is recognised, he/she will immediately be deleted
8) Deleting all users (fingerprints and badges only)
Present the Delete badge and leave it in front of the reader for 10 seconds then wait for the confirmation BEEP
Technical manual PACKSOLO
– V1.5 p.19/24
Restore to factory settings
Switch off the power
Note : Should you lose your configuration badges, you need to reset the reader to its factory settings in order to register a new set of configuration badges. This process will delete all the users (fingerprints only and badges).
To restore to factory settings:
Press the
RESET button and hold it down while switching the power back on
Wait for 10 seconds
After 10 seconds, the green and blue
LEDs will flash alternately, now proceed with activation
Technical manual PACKSOLO
– V1.5 p.20/24
Signaling LEDs
An explanation of the different status of the blue and green LEDs:
Blue LED Green LED Reader status
Flashing alternately
Flashing Off
Reader in factory configuration: waiting for configuration badges/cards ( Add , Add Alarm , Delete )
Normal operation: waiting for a user
-
On
On
-
Door open
Alarm activated: Refusing “standard” users and waiting for inactivation of the alarm (alarm fingerprint or manual inactivation)
The fingerprint sensor is off when no fingerprint is stored. The fingerprint is on (red) when at least one fingerprint is stored.
Technical manual PACKSOLO
– V1.5
Connector blocks
p.21/24
Technical manual PACKSOLO
– V1.5
Check list
Pack SOLO
Serial number
ID number
Gasket
Torx bit
Torx screw
Bag
Wall seal
:
:
:
:
:
:
: p.22/24
Technical manual PACKSOLO
– V1.5 p.23/24
Notes
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
Technical Support: [email protected]
Zone Commerciale et Artisanale
670, route de Berre
13510 EGUILLES
France www.eden-innovations.com
Descargar