Ducati EVE 01, EVO 748, HC 819, SW 3000, SW 7000 Installation Manual
Reklama
Reklama
Watch our support video
KONTROL “large”
KONTROl “small”
Swing gate openers Installation manual
EVE actuators
HC actuators
SW actuators
certified
ITAL
Y
REV 10 29-11-16 ENG d u c a t i h o m e . i t
KIT CONTENTS:
HC418 HC312 HC412 HC512 HC612 SW400 SW400T EVO700 EVO700T EVE900 EVE 900T
HC 819
HC 812-300
HC 812-400
HC 812-300 SOLAR
HC 812-400 SOLAR
HC 812-400 PRO
HC 812-500 PRO
HC 812-600 PRO
SW 3000
SW 7000
SW 7000 T
SW 7000 T SOLAR
EVO 748
EVO 748 T
EVO 748 SOLAR
EVO 748 T SOLAR
EVE 01
EVE 01 T
EVE 01 SOLAR
2x (12V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12V)
-
2x (12V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12V)
-
2x (12V)
2x ( 24V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x ( 24V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x ( 24V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12V)
2x (12V)
-
-
-
-
-
-
-
-
-
-
2x (12V)
2x (12V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12 or 24V )
-
2x (12 or 24V )
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12 or 24V )
-
-
-
-
-
2x (12 or 24V )
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12 or 24V )
-
2x (12 or 24V )
2x (12 or 24V )
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
EVE 01 T SOLAR 2x (12 or 24V )
ADDITIONAL CUSTOMIZED KIT COMPOSITIONS COULD BE ALSO AVAILABLE CHECK KIT COMPOSITION ON YOUR ORDER
KONTROL
7851
CTH41
KONTROL
7855
CTH42
1x
-
-
-
-
-
-
-
1x
-
-
-
-
-
-
-
-
-
1x
1x
-
-
-
-
-
-
-
-
1x
1x
-
1x
-
-
-
-
-
-
-
-
-
1x
1x
-
-
KONTROL
7857
CTH44
KOTROL
9048
CTH48
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1x (12 or 24V )
1x (12 or 24V )
1x (12 or 24V )
1x
1x
1x
-
-
-
-
-
KONTROL
9048/24V
FIXING
BRACKET
SET
R15
Unlcking key
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1x (12 or 24V ) 1 x 1x
-
-
-
-
-
-
-
-
-
-
-
-
1x (12 or 24V )
1x (12 or 24V )
1x (12 or 24V )
1x (12 or 24V )
1 x
1 x
1 x
1 x
1x
1x
1x
1x key switch
SW5000
1x
-
-
1x
1x
-
-
1x
1x
1x
1x
1x
1x
1x
1x
remote control
6203R
/6204
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
1x
1x
1x
1x
-
-
-
-
-
-
-
-
SW6500 keypad
TASTY
6500 keypad
FLASH
7500 blinker
SW
7500 blinker
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1x
1x
-
-
-
-
-
-
-
-
-
1x
1x
1x
1x
1x
1x
-
1x
-
-
-
-
-
-
1x
-
-
-
-
-
-
1x
1x
1x
-
1x
1x
1x
1x
1x 1x -
-
-
-
-
1x
1x
1x
1x
-
-
-
-
-
1x
-
-
-
-
1x
-
-
-
-
-
-
1x
1x solar panel with fixing bracket battery
1x
-
-
1x
1x
-
1x
-
-
-
-
1x12v 2 x 24V
1x12v 2
-
-
-
-
1x
1x
-
x 24V
-
-
1x12v 2 x 24V
1x12v 2 x 24V pair of safety beam / photocells pair of safety beam / photocells
-
-
-
-
-
-
-
1x
1x
1x
-
-
1x
-
1x
-
-
-
-
-
-
-
-
-
-
-
1x
1x
1x
-
-
-
-
1x
-
-
-
-
2
KIT CONTENTS:
HC418 HC312 HC412 HC512 HC612 SW400 SW400T EVO700 EVO700T EVE900 EVE 900T
HC 819
HC 812-300
HC 812-400
HC 812-300 SOLAR
HC 812-400 SOLAR
HC 812-400 PRO
HC 812-500 PRO
HC 812-600 PRO
SW 3000
SW 7000
SW 7000 T
SW 7000 T SOLAR
EVO 748
EVO 748 T
EVO 748 SOLAR
EVO 748 T SOLAR
EVE 01
EVE 01 T
EVE 01 SOLAR
2x (12V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12V)
-
2x (12V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12V)
-
2x (12V)
2x ( 24V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x ( 24V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x ( 24V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12V)
2x (12V)
-
-
-
-
-
-
-
-
-
-
2x (12V)
2x (12V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12 or 24V )
-
2x (12 or 24V )
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12 or 24V )
-
-
-
-
-
2x (12 or 24V )
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2x (12 or 24V )
-
2x (12 or 24V )
2x (12 or 24V )
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
EVE 01 T SOLAR 2x (12 or 24V )
ADDITIONAL CUSTOMIZED KIT COMPOSITIONS COULD BE ALSO AVAILABLE CHECK KIT COMPOSITION ON YOUR ORDER
KONTROL
7851
CTH41
KONTROL
7855
CTH42
1x
-
-
-
-
-
-
-
1x
-
-
-
-
-
-
-
-
-
1x
1x
-
-
-
-
-
-
-
-
1x
1x
-
1x
-
-
-
-
-
-
-
-
-
1x
1x
-
-
KONTROL
7857
CTH44
KOTROL
9048
CTH48
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1x (12 or 24V )
1x (12 or 24V )
1x (12 or 24V )
1x
1x
1x
-
-
-
-
-
KONTROL
9048/24V
FIXING
BRACKET
SET
R15
Unlcking key
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1 x
1x (12 or 24V ) 1 x 1x
-
-
-
-
-
-
-
-
-
-
-
-
1x (12 or 24V )
1x (12 or 24V )
1x (12 or 24V )
1x (12 or 24V )
1 x
1 x
1 x
1 x
1x
1x
1x
1x key switch
SW5000
1x
-
-
1x
1x
-
-
1x
1x
1x
1x
1x
1x
1x
1x
remote control
6203R
/6204
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
1x
1x
1x
1x
-
-
-
-
-
-
-
-
SW6500 keypad
TASTY
6500 keypad
FLASH
7500 blinker
SW
7500 blinker
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1x
1x
-
-
-
-
-
-
-
-
-
1x
1x
1x
1x
1x
1x
-
1x
-
-
-
-
-
-
1x
-
-
-
-
-
-
1x
1x
1x
-
1x
1x
1x
1x
1x 1x -
-
-
-
-
1x
1x
1x
1x
-
-
-
-
-
1x
-
-
-
-
1x
-
-
-
-
-
-
1x
1x solar panel with fixing bracket battery
1x
-
-
1x
1x
-
1x
-
-
-
-
1x12v 2 x 24V
1x12v 2
-
-
-
-
1x
1x
-
x 24V
-
-
1x12v 2 x 24V
1x12v 2 x 24V pair of safety beam / photocells pair of safety beam / photocells
-
-
-
-
-
-
-
1x
1x
1x
-
-
1x
-
1x
-
-
-
-
-
-
-
-
-
-
-
1x
1x
1x
-
-
-
-
1x
-
-
-
-
3
D U C A T I
I N D E X
How to read this general manual
This manual contains the general instructions for all HC, SW, EVE And ARTIKO openers and is divided into three general sections.
Mechanical istallation of the motors.
Instalaltion of the control box, wiring and control board adjustments
Accessories instructions.
Identify your actuator model and your electronic board model through the labels that you’ll find on your control box and actuator and follow the instructions
Electromechanical actuators for swing gates page
Actuator’s Comparison Table: shows technical features, and usage limits
General installation diagram
Pillar dimension, measure A& B , gate stop limit
HC312 actuator installation limits, drawings
HC412 actuator installation limits, drawings
HC512 actuator installation limits, drawings
HC612 actuator installation limits, drawings
9
10
11
6
8
5
6
HC418 actuator installation limits, drawings
HC518 actuator installation limits, drawings
HC618 actuator installation limits, drawings
12
13
14
SW400 actuator installation limits, drawings 15
SW400T actuator installation limits, drawings
EVO700 actuator installation limits, drawings
16
17
EVO700T actuator installation limits, drawings
EVE900 actuator installation limits, drawings
EVE900T actuator installation limits, drawings
EVE actuators: specific drawings
HC actuators: specific drawings
SW actuators: specific drawings
How to install the actuators
1) General characteristics
2) Preliminary safety warnings
3) General Installation scheme
4) Post mounting bracket
5) Front mounting bracket
6) manual release
4
7) Mechanical Limits
8) Final check of correct installation
18
19
20
21
22
23
24-26
24
24
25
25
25
25
26
26
Control boxes
Control box “kontrol small” & “ kontrol large”
Main power supply 230V/110V electronic board: CTH41 & CTH41MONO
CTH42
CTH44
CTH48
Accessories
Remote controls 6203 6203R /P e 6204
Remote control Gemini 6205
Radio Keypad
Key switches
External additional Radio-receiver 6040 ROL
External additional Radio-receiver with display 6043
Photocells
Light blinkers a& external Antennas
Solar panels with consumption table
Accessories summary
Spare parts
Spare parts: actuator’s exploded view
Spare parts summary
Safety, certificates, Warranty & Assistance
Safety, test report and CE compliance certifications
Warranty, assistance procedure
FAQ pag
27
28
29-30
30-32
33-35
35 -40
46-48
49
50
51-53 pag
54 pag
41
42
43
44
45
46
55-58 pag
59
60
61-62
DUCATI
actuator’s technical data comparison actuator model
HC 312
HC 312/ 24 V
HC 412
HC 412 / 24V
HC 512
HC 512 / 24V
HC 612
HC 612/ 24V
HC 418
HC 418 /24V
HC 518
HC518 /24V
HC 618
HC618 / 24V
SW400
SW400 / 24V
SW400 T
SW400 T /24V
EVO 700
EVO 700 /24V
EVO 700T
EVO 700T /24V
EVE 900
EVE 900 /24V
EVE 900 T
EVE 900 T /24V see page power supply
12
12
13
13
5 12V 60W 1200 300
5 24V 120W 2400 300
6 12V 60W 1200 400
6 24V 120W 2400 400
7 12V 60W 1200 500
7 24V 120W 2400 500
8 12V 60W 1200 600
8 24V 120W 2400 600
9 12V 60W 1200 400
9 24V 120W 2400 400
10 12V 60W 1200 500
10 24V 120W 2400 500
11 12V 60W 1200 600
11 24V 120W 2400 600
14
14
15
15
16
16
17
17
W N stoke
(mm) speed
(cm/sec)
telescopic tube ideal for continuous use
working temperature
12V 60W 1200 400
24V 120W 2400 400
12V 60W 1200 400
24V 120W 2400 400
12V 60W 1200 500
24V 120W 2400 500
12V 60W 1200 500
24V 120W 2400 500
12V 60W 1200 500
24V 120W 2400 500
12V 60W 1200 500
24V 120W 2400 500
1,5
2
1,5
2
1,5
2
1,5
2
1,5
2
1,5
2
1,5
1,5
2
1,5
2
2
1,5
2
1,5
2
1,5
2
1,5
2
-
-
√
√
√
√
-
-
√
√
-
-
√
√
√
√
√
√
√
√
-
-
-
-
-
-
√
√
√
√ on board mechanical limit for closed position on board mechanical limit for open
position on board electric limit for closed & open position
Max. wing lenght
( L )
√ -20°C/+60°C
√ -20°C/+60°C
√ -20°C/+60°C
√ -20°C/+60°C -
-
-
FC version only
FC version only
FC version only
√ -20°C/+60°C
√ -20°C/+60°C
√ -20°C/+60°C
√ -20°C/+60°C
-
-
-
FC version only
FC version only
FC version only
FC version only
FC version only
√ -20°C/+60°C FC version only FC version only
√ -20°C/+60°C FC version only FC version only
√ -20°C/+60°C FC version only FC version only
√ -20°C/+60°C FC version only FC version only
√ -20°C/+60°C -FC version only FC version only
√ -20°C/+60°C FC version only FC version only
√ -20°C/+60°C FC version only FC version only
√ -20°C/+60°C FC version only FC version only
√ -20°C/+60°C FC version only
√ -20°C/+60°C FC version only FC version only
-20°C/+60°C FC version only FC version only
-20°C/+60°C FC version only FC version only
-20°C/+60°C
-20°C/+60°C
√ -20°C/+60°C
√ -20°C/+60°C
√ -20°C/+60°C
√ -20°C/+60°C
√
√
√
√
-
FC version only
FC version only
√
√
√
√
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
√
-
√
-
-
FCA version only
FCA version only
FC version Aonly
FCA version only
2,5m 250 kg 125°
2,5m 350 kg 125°
3,5m 350 kg 137°
3,5m 450 kg 137°
4m
4m
5m
5m
400 kg 137°
500 kg 137°
400 kg 137°
500 kg 137°
2m
2m
3m
3m
4m
4m
2m
2m
2,6m
2,6m
4m
4m
5m
5m
4m
4m
5m
5m
Max wing weight
200 kg
300 kg
350 kg
450 kg
350kg
450kg
200 kg
300 kg
260 kg
360 kg
350 kg
450 kg
350 kg
450 kg
450 kg
550 kg
400 kg
500 kg
Max. opening angle
Manual relese system
Compatible with key protected manual release optional accessory
Automatic wing lock
120°
120°
120°
120°
135°
135°
125°
125°
130°
130°
140°
140°
135°
135°
130°
130°
135°
135°
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SW LOCK
SW LOCK
SW LOCK
SW LOCK
SW LOCK
SW LOCK
SW LOCK
SW LOCK
EVE LOCK
EVE LOCK
EVE LOCK
EVE LOCK
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
5
8
5
1 3
4
GENERAL INSTALLATION DIAGRAM
L
9
2
9
2
9
9
7
Icons meaning
Low consumption technology
6
Compatible with solar panel power supply
Compatible with emergency battery
AUTO-LOCK SYSTEM
Automatic lock the gate wen closed.
REVERSAL SYSTEM on obstacle detection
PEDESTRIAN access. opens one wing partially
SOFT-STOP double speed with soft approaching
6
DUCATI
General installation diagram: mechanical limits & pillar dimension
PULL TO OPEN OPERATION (gate that opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
Pillar dimension:
How this influences your gate opener system.
Determinate the ideal A & B measure
A= distance between the hinges of the gate and the actuator’s post fixing pin. This distance can be chosen by the user. We recommend to use a measure similar to the “B” measure.
K
H
V B= is te most relevant measure and determinates gate opening speed and max. opening angle. it’s determinated by the pillar dimension+ fixing bracket.
Shorter B measure determinates faster opening of your gate.
If you require major opening angle choose a short B measure and longer A measure
V= gate hinges
K = post fixing bracket
H = front fixing bracket
Longer telescopic actuators, allow better mechanical operation given by the greater strength of the lever.
Carefully evaluate the size of the pillars in relation to the tables that you will find in the pages that present the limits of use and overall dimensions of each actuator model. In some cases it may be required masonry work to install your opener
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property. Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation .
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
In line with center hinge
OUTSIDE
INSIDE
Rear pivot point of gate opener
A= this measure must allow the actuator to be parallel to the door open at
90 °.
B= This measure allows the actuator mounting. Compare it to the actuator dimension
Longer telescopic actuators, allow better mechanical operation.Make sure that the gate do not open onto a public passageway. It is advisable to prepare a plant with safety photocells to be placed in such a way that the doors, opening towards the outside do not create damages to things and people who are on the outside of the property, such as parked vehicles.
1°
Example of endstop fixed to the ground
Mechanical GATE STOPS (END STOPS):
T he gate leaves must stop on the mechanical limits (end stops fixed to the ground) in the gate open & closed position. Make sure your gate has end stops fixed on the ground. FC version actuators are provided with on-board mechanical limits. this avoids to build endstops limit fixed on the floor.
Warning: FC telescopic actuators version are equipped with on-board mechanicla limit for open position only. EVE actuators and FC non telescopic actuatora are equipped with on-board limits for both open & closed position
Warning: make sure that the actuator is always stops at the limit switch and not use all of its travel
15 cm min.
1°= M1 ( wing that opens first )
2°= M2
END STOPS
15 cm min.
7
8
DUCATI
actuator model HC312
Installation diagram
HC312
HC312 FC (with on board open position mechanical limit) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
In line with center hinge OUTSIDE
Maximal wing dimension:
Maximal wing lenght: up to 2,5m/ 8 ft
Maximal wing weight: up to 250kg/ 500lb
INSIDE
620÷920 mm
Rear pivot point of gate opener
100 mm
160 mm
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
20 cm = 7 7/8” = 7,87 ”
25 cm = 9 3/4" = 9,8 ”
30cm = 11 8/9” = 11,8 ” maximal dimension
B=8 cm
B= 10cm
B= 12cm
B= 14cm
B= 16cm
B= 18cm
B= 20cm
A=8 cm A=10 cmA=12 cmA=14 cmA=18 cmA=20 cm
98°
97°
95°
95°
94°
94°
93°
110°
108°
105°
103°
101°
97°
/
118°
115°
112°
109°
97°
/
/
125°
120°
110°
98°
90°
/
/
/
/
/
108°
100°
100°
/
/
/
/
100°
94°
93°
/
620 -920 mm
Supplied fixing braket: choose the hole most suitable to your gate. you can cut the plate if necessary
Post fixing Front fixing
10cm
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation .
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
OUTSIDE
D= 11cm D= 13cm
A = min. 8cm max. 14cm
B = min. 8cm max. 14cm
INSIDE
DUCATI
actuator model HC312
Installation diagram
DUCATI
actuator model HC412
Installation diagram
HC412
HC412 FC (with on board open position mechanical limit) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
In line with center hinge OUTSIDE
Maximal wing dimension:
Maximal wing lenght: up to 3,5m/ 11 ft
Maximal wing weight: up to 300kg/ 660lb
720÷1120 mm
100 mm
160 mm
INSIDE
Rear pivot point of gate opener
TAB A= 8cm A= 10cm A= 12cm A= 14cm A= 16 cm A= 18cm A= 20cm A= 22cm A= 24cm A= 26cm A= 28cm
B= 8cm 16 sec/97° 18sec/110° 21sec/118° 23sec/125° 23sec/130° 24sec/135° 26sec/137° 27sec/115° 31sec/108° 32sec/103° 32sec/105°
B= 10cm 18sec/98° 19sec/107° 22sec/114° 23sec/121° 25sec/127° 27sec/131° 27sec/125° 29sec/115° 31sec/108° 32sec/103° 33sec/99°
B= 12cm 20sec/98° 23sec/105° 24sec/112° 26sec/118° 27sec/124° 29sec/127° 30sec/120° 33sec/110° 34sec/104° 35sec/100° 369sec/96°
B= 14cm 21sec/95° 24sec/103° 25sec/108° 27sec/105° 28sec/120° 30sec/125° 32sec/111° 33sec/105° 35sec/99° 36sec/95° 37sec/93°
B= 16cm 23sec/94° 25sec/102° 28sec/108° 30sec/103° 31sec/118° 33sec/113° 34sec/102° 35sec/98° 37sec/94° 38sec/90°
B= 18cm 26sec/94° 27sec/100° 29sec/106° 32sec/111° 33sec/115° 34sec/105° 36sec/97° 36sec/93° 38sec/90°
B= 20cm 28sec/94° 30sec/100° 32sec/105° 34sec/109° 35sec/103° 37sec/96° 40sec/90°
B= 22cm 29sec/93° 33sec/99° 33sec/103° 34sec/106° 37sec/95° 38sec/90°
B= 24cm 32sec/93 34sec/99 36sec/102 37sec/93°
B= 26cm 34sec/93° 36sec/98° 37sec/92°
B= 28cm 38sec/93°
720 -1120 mm
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
20 cm = 7 7/8” = 7,87 ”
25 cm = 9 3/4" = 9,8 ”
28 cm = 11 ”
Supplied fixing braket: choose the hole most suitable to your gate. you can cut the plate if necessary
Post fixing Front fixing
10cm
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation
.
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
OUTSIDE
D= 11cm D= 13cm A = min. 8cm max. 14cm
B = min. 8cm max. 14cm
INSIDE
9
DUCATI
actuator model HC512
Installation diagram
HC512
HC512 FC (with on board open position mechanical limit) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
In line with center hinge OUTSIDE
Maximal wing dimension:
Maximal wing lenght: up to 4m/ 14 ft
Maximal wing weight: up to 400kg/ 860lb
820÷1320 mm
10 cm
16 cm
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
20 cm = 7 7/8” = 7,87 ”
25 cm = 9 3/4" = 9,8 ”
30cm = 11 8/9” = 11,8 ”
INSIDE
TAB
Rear pivot point of gate opener
A= 8cm A= 10cm A= 12cm A= 14cm A= 16 cm A= 18cm A= 20cm A= 22cm A= 24cm A= 26cm A= 28cm
B= 8cm 16 sec/97° 18sec/110° 21sec/118° 23sec/125° 23sec/130° 24sec/135° 26sec/137° 27sec/115° 31sec/108° 32sec/103° 32sec/105°
B= 10cm 18sec/98° 19sec/107° 22sec/114° 23sec/121° 25sec/127° 27sec/131° 27sec/125° 29sec/115° 31sec/108° 32sec/103° 33sec/99°
B= 12cm 20sec/98° 23sec/105° 24sec/112° 26sec/118° 27sec/124° 29sec/127° 30sec/120° 33sec/110° 34sec/104° 35sec/100° 369sec/96°
B= 14cm 21sec/95° 24sec/103° 25sec/108° 27sec/105° 28sec/120° 30sec/125° 32sec/111° 33sec/105° 35sec/99° 36sec/95° 37sec/93°
B= 16cm 23sec/94° 25sec/102° 28sec/108° 30sec/103° 31sec/118° 33sec/113° 34sec/102° 35sec/98° 37sec/94° 38sec/90°
B= 18cm 26sec/94° 27sec/100° 29sec/106° 32sec/111° 33sec/115° 34sec/105° 36sec/97° 36sec/93° 38sec/90°
B= 20cm 28sec/94° 30sec/100° 32sec/105° 34sec/109° 35sec/103° 37sec/96° 40sec/90°
B= 22cm 29sec/93° 33sec/99° 33sec/103° 34sec/106° 37sec/95° 38sec/90°
B= 24cm 32sec/93 34sec/99 36sec/102 37sec/93°
B= 26cm 34sec/93° 36sec/98° 37sec/92°
B= 30cm 38sec/93°
820 -1320 mm
Supplied fixing braket: choose the hole most suitable to your gate. you can cut the plate if necessary
Post fixing Front fixing
10cm
PUSH TO OPEN OPERATION (opens towards inside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation
.
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
OUTSIDE
D= 11cm D= 13cm
A = min. 8cm max. 14cm
B = min. 8cm max. 14cm
INSIDE
10
DUCATI
actuator model HC512
Installation diagram
DUCATI
actuator model HC612
Installation diagram
HC612
HC612 FC (with on board open position mechanical limit) each model is also available in 24V version
Maximal wing dimension:
Maximal wing lenght: up to 5m/ 16 ft
Maximal wing weight: up to 500kg/ 110lb
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
In line with center hinge OUTSIDE
920÷1520 mm
920 -1520 mm
100 mm
160 mm
Supplied fixing braket: choose the hole most suitable to your gate. you can cut the plate if necessary
Post fixing
10cm
Front fixing
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
20 cm = 7 7/8” = 7,87 ”
25 cm = 9 3/4" = 9,8 ”
35cm = 13 4/5 = 13,7 ”
INSIDE
Rear pivot point of gate opener
TAB
A= 8cm A= 10cm A= 12cm A= 14cm A= 16 cm A= 18cm A= 20cm A= 22cm A= 24cm A= 26cm A= 28cm
B= 8cm 16 sec/97° 18sec/110° 21sec/118° 23sec/125° 23sec/130° 24sec/135° 26sec/137° 27sec/115° 31sec/108° 32sec/103° 32sec/105°
B= 10cm 18sec/98° 19sec/107° 22sec/114° 23sec/121° 25sec/127° 27sec/131° 27sec/125° 29sec/115° 31sec/108° 32sec/103° 33sec/99°
B= 12cm 20sec/98° 23sec/105° 24sec/112° 26sec/118° 27sec/124° 29sec/127° 30sec/120° 33sec/110° 34sec/104° 35sec/100° 369sec/96°
B= 14cm 21sec/95° 24sec/103° 25sec/108° 27sec/105° 28sec/120° 30sec/125° 32sec/111° 33sec/105° 35sec/99° 36sec/95° 37sec/93°
B= 16cm 23sec/94° 25sec/102° 28sec/108° 30sec/103° 31sec/118° 33sec/113° 34sec/102° 35sec/98° 37sec/94° 38sec/90°
B= 18cm 26sec/94° 27sec/100° 29sec/106° 32sec/111° 33sec/115° 34sec/105° 36sec/97° 36sec/93° 38sec/90°
B= 20cm 28sec/94° 30sec/100° 32sec/105° 34sec/109° 35sec/103° 37sec/96° 40sec/90°
B= 22cm 29sec/93° 33sec/99° 33sec/103° 34sec/106° 37sec/95° 38sec/90°
B= 24cm 32sec/93 34sec/99 36sec/102 37sec/93°
B= 26cm 34sec/93° 36sec/98° 37sec/92°
B= 35cm 38sec/93°
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation
.
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
OUTSIDE
D= 11cm D= 13cm A = min. 8cm max. 14cm
B = min. 8cm max. 14cm
INSIDE
11
DUCATI
actuator model HC418
Installation diagram
HC418
HC418 FC (with on board open& closed position mechanical limits) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
OUTSIDE
Maximal wing dimension:
Maximal wing lenght: up to 2m/ 6,5 ft
Maximal wing weight: up to 200kg/ 440lb
In line with center hinge
INSIDE
720 mm
Rear pivot point of gate opener
100 mm
160 mm maximal dimension
B= 10cm
B= 12cm
B= 14cm
B= 16cm
B= 18cm
A=10 cm A=12cm A=14 cm A=18 cm
108°
105°
103°
101°
97°
115°
112°
109°
97°
/
120°
100°
98°
90°
/
100°
100°
/
/
/
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
180 -560 mm
Supplied fixing braket: choose the hole most suitable to your gate.
You can cut the plate if necessary
D = 5,4cm
D = 2,5cm
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation .
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
D = 2,5cm NOT POSSIBLE WITH THIS ACTUATOR MODEL: IT REQUIRES TELESCOPIC ACTUATORS
D = 6cm
D = 8,5cm
D = 10cm
12
DUCATI
actuator model HC418
Installation diagram
DUCATI
actuator model HC518
Installation diagram
HC518
HC518 FC (with on board open& closed position mechanical limits) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
Maximal wing dimension:
Maximal wing lenght: up to 3m/ 8,5 ft
Maximal wing weight: up to 300kg/ 760lb
In line with center hinge OUTSIDE
INSIDE
820 mm
100 mm
160 mm maximal dimension
B= 10cm
B= 12cm
B= 14cm
B= 16cm
B= 18cm
B = 22 cm
Rear pivot point of gate opener
A=10 cm A=12cm A=14 cm A=18 cm
108°
105°
103°
101°
97°
90 °
115°
112°
109°
97°
/
/
120°
100°
98°
90°
/
/
100°
100°
/
/
/
/
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
180 -660 mm
Supplied fixing braket: choose the hole most suitable to your gate.
You can cut the plate if necessary
D = 5,4cm
D = 2,5cm
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation
.
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
D = 2,5cm NOT POSSIBLE WITH THIS ACTUATOR MODEL: IT REQUIRES TELESCOPIC ACTUATORS
D = 6cm
D = 8,5cm
D = 10cm
13
DUCATI
actuator model HC618
Installation diagram
HC618
HC618 FC (with on board open& closed position mechanical limits) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
Maximal wing dimension:
Maximal wing lenght: up to4m/ 10 ft
Maximal wing weight: up to 300kg/ 760lb
In line with center hinge OUTSIDE
INSIDE
920 mm
100 mm
160 mm maximal dimension
B= 10cm
B= 12cm
B= 14cm
B= 16cm
B= 18cm
B = 25 cm
A=8 cm
108°
105°
103°
101°
97°
90 °
Rear pivot point of gate opener
A=12cm A=14 cm A=18 cm
115°
112°
109°
97°
/
/
120°
100°
98°
90°
/
/
100°
100°
/
/
/
/
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
180 -760 mm
Supplied fixing braket: choose the hole most suitable to your gate.
You can cut the plate if necessary
D = 5,4cm
D = 2,5cm
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation .
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
D = 2,5cm NOT POSSIBLE WITH THIS ACTUATOR MODEL: IT REQUIRES TELESCOPIC ACTUATORS
D = 6cm
D = 8,5cm
D = 10cm
14
DUCATI
actuator model HC618
Installation diagram
DUCATI
actuator model SW400
Installation diagram
SW400
SW400 FC (with on board open & closed position mechanical limits) each model is also available in 24V version
Maximal wing dimension:
Maximal wing lenght: up to 2m/ 6,5 ft
Maximal wing weight: up to 200kg/ 440lb
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
OUTSIDE
In line with center hinge
140 mm
100 mm
175 mm - 530mm
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
INSIDE
Rear pivot point of gate opener
TAB
B= 10cm
B= 12cm
B= 14cm
B= 16cm
B= 18cm
A=10 cm A=12cm A=14 cm A=18 cm
108° 115° 120° 100°
105°
103°
112°
109°
100°
98°
100°
/
101°
97°
97°
/
90°
/ /
/
Supplied fixing braket: choose the hole most suitable to your gate.
You can cut the plate if necessary
D = 5,4cm
D = 2,5cm
D = 2,5cm
D = 6cm
D = 8,5cm
D = 10cm
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation .
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
NOT POSSIBLE WITH THIS ACTUATOR MODEL: IT REQUIRES TELESCOPIC ACTUATORS
15
DUCATI
actuator model SW400T
Installation diagram
SW400 T
SW400T FC (with on board open position mechanical limit) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
In line with center hinge OUTSIDE
Maximal wing dimension:
Maximal wing lenght: up to 2,6m/ 8,5 ft
Maximal wing weight: up to 250kg/ 500lb
INSIDE
Rear pivot point of gate opener
TAB 3 A= 8cm A= 10cm A= 12cm A= 14cm A= 16 cm A= 18cm A= 20cm A= 22cm A= 24cm A= 26cm A= 28cm
140 mm
100 mm
640 mm - 1040mm
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
20 cm = 7 7/8” = 7,87 ”
25 cm = 9 3/4" = 9,8 ”
28 cm = 11 ”
B= 8cm
B= 22cm
16 sec/97° 18sec/110° 21sec/118° 23sec/125° 23sec/130° 24sec/135° 26sec/137° 27sec/115° 31sec/108° 32sec/103° 32sec/105°
B= 10cm 18sec/98° 19sec/107° 22sec/114° 23sec/121° 25sec/127° 27sec/131° 27sec/125° 29sec/115° 31sec/108° 32sec/103° 33sec/99°
B= 12cm 20sec/98° 23sec/105° 24sec/112° 26sec/118° 27sec/124° 29sec/127° 30sec/120° 33sec/110° 34sec/104° 35sec/100° 369sec/96°
B= 14cm 21sec/95° 24sec/103° 25sec/108° 27sec/105° 28sec/120° 30sec/125° 32sec/111° 33sec/105° 35sec/99° 36sec/95° 37sec/93°
B= 16cm 23sec/94° 25sec/102° 28sec/108° 30sec/103° 31sec/118° 33sec/113° 34sec/102° 35sec/98° 37sec/94° 38sec/90°
B= 18cm 26sec/94° 27sec/100° 29sec/106° 32sec/111° 33sec/115° 34sec/105° 36sec/97° 36sec/93° 38sec/90°
B= 20cm 28sec/94° 30sec/100° 32sec/105° 34sec/109° 35sec/103° 37sec/96° 40sec/90°
29sec/93° 33sec/99° 33sec/103° 34sec/106° 37sec/95° 38sec/90°
B= 24cm 32sec/93 34sec/99 36sec/102 37sec/93°
B= 26cm 34sec/93° 36sec/98° 37sec/92°
B= 28cm 38sec/93°
Supplied fixing braket: choose the hole most suitable to your gate. you can cut the plate if necessary
Post fixing
10cm
Front fixing
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation
.
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
OUTSIDE
D= 11cm D= 13cm A = min. 8cm max. 14cm
B = min. 8cm max. 14cm
INSIDE
16
DUCATI
actuator model SW400T
Installation diagram
DUCATI
actuator model EVO 700
Installation diagram
EVO 700
EVO 700 FC (with on board open & closed position mechanical limits) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
In line with center hinge
OUTSIDE
Maximal wing dimension:
Maximal wing lenght: up to 4m/ 14 ft
Maximal wing weight: up to 350kg/ 760lb INSIDE
140 mm
100 mm
260 mm - 760mm
Supplied fixing braket: choose the hole most suitable to your gate.
You can cut the plate if necessary
D = 5,4cm
D = 6cm
D = 8,5cm
D = 10cm
D = 2,5cm
D = 2,5cm
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
20 cm = 7 7/8” = 7,87 ”
25 cm = 9 3/4" = 9,8 ”
35cm = 13 4/5 = 13,7 ”
Rear pivot point of gate opener measures are in cm
TAB A-9 A-11 A-13 A-15 A-17 A-19 A-21 A-23
B-8
B-9
105°12sec 115°15sec 125°15sec 130°20sec 130°27sec 140°25sec 135°27sec 90°
105°13sec 115°15sec 120°18sec 125°20sec 130°23sec 135°25sec 120°
B-12 100°14sec 110°17sec 115°19sec 120°21sec 120°23sec 125°26sec 120°
B-15 105°17sec 105°19sec 110°21sec 115°23sec 120°26sec 125°28sec 125°30sec
90°
90°
B-18 100°18sec 105°20sec 110°23sec 115°25sec 115°27sec 120°29sec 100°28sec
B-21 105°20sec 100°22sec 105°24sec 110°26sec 110°28sec
B-25
B-29
95°23sec 100°25sec 105°27sec 110°29sec 110°31sec
95°27sec 100°28sec 100°30sec 105°32sec
B-33 95°30sec 95°32sec 90°32sec
B-35 95°32sec 95°33sec
A-25
105°
105°
105°
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation
.
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
NOT POSSIBLE WITH THIS ACTUATOR MODEL: IT REQUIRES TELESCOPIC ACTUATORS
17
DUCATI
actuator model EVO 700T
Installation diagram
EVO 700 T
EVO 700 T FC (with on board open position mechanical limit) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
In line with center hinge OUTSIDE
Maximal wing dimension:
Maximal wing lenght: up to 5m/ 16 ft
Maximal wing weight: up to 350kg/ 760lb
INSIDE
Rear pivot point of gate opener measures are in cm
TAB
A-9 A-11 A-13 A-15
140 mm
100 mm
870 mm - 1370mm
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
20 cm = 7 7/8” = 7,87 ”
25 cm = 9 3/4" = 9,8 ”
35cm = 13 4/5 = 13,7 ”
B-9
B-21 105°20sec 100°22sec 105°24sec 110°26sec 110°28sec
B-25
B-29
B-33
95°27sec 100°28sec 100°30sec 105°32sec
95°30sec 95°32sec 90°32sec
A-17
95°23sec 100°25sec 105°27sec 110°29sec 110°31sec
A-19 A-21 A-23
105°21sec 115°22sec 120°23sec 120°23sec 125°23sec 130°25sec 135°26sec 135°26sec 120°23sec
B-11 105°21sec 115°22sec 115°22sec 115°22sec 120°23sec 125°23sec 130°25sec 90°18sec
A-25
115°22sec
B-13 100°20sec 105°21sec 110°21sec 115°22sec 115°22sec 120°23sec 125°23sec 125°23sec 105°21sec
B-15 105°17sec 105°19sec 110°21sec 115°23sec 120°26sec 125°28sec 125°30sec 125°23sec 105°21sec
B-18 100°18sec 105°20sec 110°23sec 115°25sec 115°27sec 120°29sec 100°28sec 105°21sec 100°20sec
B-35 95°32sec 95°33sec
Supplied fixing braket: choose the hole most suitable to your gate. you can cut the plate if necessary
Post fixing
10cm
Front fixing
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation
.
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
OUTSIDE
D= 11cm D= 13cm
18
A = min. 8cm max. 14cm
B = min. 8cm max. 14cm
INSIDE
DUCATI
actuator model EVO 700T
Installation diagram
140 mm
DUCATI
actuator model EVE 900
Installation diagram
EVE900 FC
EVE900 FCA (with on board open & closed position mechanical limits) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
In line with center hinge OUTSIDE
Maximal wing dimension:
Maximal wing lenght: up to 4m/ 14 ft
Maximal wing weight: up to 450kg/ 1000lb
INSIDE
260 mm - 760mm
Multi-position fixing braket: choose the hole most suitable to your gate. front fixing bracket multiposition post fixing bracket
30 mm
120 mm
100 mm
50 mm
105 mm
70 mm
EVE PLAK multiposition post fixing bracket with optional additional bracket # EVE PLAK
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
20 cm = 7 7/8” = 7,87 ”
25 cm = 9 3/4" = 9,8 ”
35cm = 13 4/5 = 13,7 ”
Rear pivot point of gate opener measures are in cm
TAB
B-8
A-9 A-11 A-13 A-15 A-17 A-19 A-210 A-23
105°12sec 115°15sec 125°15sec 130°20sec 130°27sec 140°25sec 135°27sec 90°
90° B-9 105°13sec 115°15sec 120°18sec 125°20sec 130°23sec 135°25sec 120°
B-12 100°14sec 110°17sec 115°19sec 120°21sec 120°23sec 125°26sec 120°
B-15 105°17sec 105°19sec 110°21sec 115°23sec 120°26sec 125°28sec 125°30sec
90°
B-18 100°18sec 105°20sec 110°23sec 115°25sec 115°27sec 120°29sec 100°28sec
B-21 105°20sec 100°22sec 105°24sec 110°26sec 110°28sec
B-25
B-29
95°23sec 100°25sec 105°27sec 110°29sec 110°31sec
95°27sec 100°28sec 100°30sec 105°32sec
B-33
B-35
95°30sec 95°32sec 90°32sec
95°32sec 95°33sec
A-25
105°
105°
105°
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation
.
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
NOT POSSIBLE WITH THIS ACTUATOR MODEL: IT REQUIRES TELESCOPIC ACTUATORS
19
140 mm
DUCATI
actuator model EVE 900T
Installation diagram
EVE900 T FC
EVE900 T FCA (with on board open & closed position mechanical limits) each model is also available in 24V version
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
In line with center hinge OUTSIDE
Maximal wing dimension:
Maximal wing lenght: up to 5m/ 16 ft
Maximal wing weight: up to 500kg/ 1100lb
870 mm - 1370mm
Multi-position fixing braket: choose the hole most suitable to your gate. front fixing bracket multiposition post fixing bracket
120 mm
30 mm
METRIC CONVERSION
1 cm = 1⁄2 ” = 0,3 ”
10 cm = 4 ”
12 cm = 4 3⁄4” = 4,7 ”
14 cm = 5 1⁄2” = 5,5“
16 cm = 6 1⁄5” = 6,2 ”
18 cm = 7 ”
20 cm = 7 7/8” = 7,87 ”
25 cm = 9 3/4" = 9,8 ”
35cm = 13 4/5 = 13,7 ”
INSIDE
Rear pivot point of gate opener measures are in cm
TAB
B-9
A-9 A-11 A-13 A-15 A-17 A-19 A-21 A-23 A-25
105°21sec 115°22sec 120°23sec 120°23sec 125°23sec 130°25sec 135°26sec 135°26sec 120°23sec
B-11 105°21sec 115°22sec 115°22sec 115°22sec 120°23sec 125°23sec 130°25sec 90°18sec 115°22sec
B-13 100°20sec 105°21sec 110°21sec 115°22sec 115°22sec 120°23sec 125°23sec 125°23sec 105°21sec
B-15 105°17sec 105°19sec 110°21sec 115°23sec 120°26sec 125°28sec 125°30sec 125°23sec 105°21sec
B-18 100°18sec 105°20sec 110°23sec 115°25sec 115°27sec 120°29sec 100°28sec 105°21sec 100°20sec
B-21 105°20sec 100°22sec 105°24sec 110°26sec 110°28sec
B-25 95°23sec 100°25sec 105°27sec 110°29sec 110°31sec
B-29
B-33
95°27sec 100°28sec 100°30sec 105°32sec
95°30sec 95°32sec 90°32sec
B-35 95°32sec 95°33sec
100 mm
50 mm
105 mm
70 mm
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swinging in. This means the gate operator is mounted on the inside of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check the overall dimensions before installation .
Warning:remember to reverse the polarity of the motor cables when connecting to the electronic board
OUTSIDE
EVE PLAK multiposition post fixing bracket with optional
A = min. 8cm max. 14cm
B = min. 8cm max. 14cm
20
INSIDE
DUCATI
actuator model EVE 900T
Installation diagram
DUCATI
EVE actuators
13
STANDARD
14A
+ optional
EVE PLAK
15A
STANDARD manual release
14B
16
On board mechanical limits
5mm
17
Electric limits adjustment: only available on EVE FC versions
15B
EVE LOCK: optional manual release protection by key
21
DUCATI
HC actuators
18A 18B 19 A
19 B
21
STANDARD manual release
22
22
Mechanical limits (only available on
“FC”versions)
LIMIT POINT
20A
20B
LIMIT POINT
DUCATI
SW & EVO actuators
23A 23B 24
26A
STANDARD manual release
26B
EVO LOCK: optional manual release protection by key
27
Mechanical limits (only available on
“FC”versions)
LIMIT POINT LIMIT POINT
25A
25B
23
D U C A T I A c t u a t o r ’ s i n s t a l l a t i o n i n s t r u c t i o n s
1. GENERAL CARACTERISTICS and PRELIMINARY WARNINGS
The products described in this manual are intended to be used to automate hinged swing gates for residential/ commercial or industrial use, within the limits of use and size provided for each model.
Incorrect installation can cause serious injuries. Before installing the automation you need to carefully read all the parts of the manual. If in doubt, stop installation and request clarification from the DUCATI
HOME Assistance Service. The structure on which you are installing must be constructed in a workmanlike manner in accordance with local regulations and satisfy all safety requirements. The automation can not correct defects in the structure. Check that the gate leaves are perfectly balanced, that the hinges are in perfect condition and that the facility is fully operational and complies with safety regulations. Gates with structural problems should not be automated Warning: Ducati actuators are designed to be installed to be used indifferently on the right or left leaf of the gate.
WARNING! Any use other than those described in this manual is to be considered improper and prohibited!
- Repair or replace all worn or damaged door components prior to installation. Call a trained professional door systems technician for this.
- To avoid entanglement, remove any unecessary ropes and disable any equipment such as locks, not needed for powered operation.
- To prevent damage to the door and opening system, always disable the locks before installing and operating the opening system.
Prevent serious injury or death by electric power:
- Be sure the power is not connected BEFORE installing the door control.
- NEVER connect the door opener to the power source until instructed to do so.
- The door installation and wiring MUST be in compliance with all local electrical and building codes
Ducati’s electromechanical actuators are provided with DC motor, worm screw gear. The motor must be run by a compatible original “DUCATI HOME automation” control unit only.
The actuator stops its movement by means of an amperometric detection system as the gate wing reach a mechanical stop (whether a fixed on the floor “STOPPER”, or an on board limit if the actuator model is featured with). In case of obstacle detection, safety is also ensured by the amperometric detection system in compliance with EN laws.
In case of power failure (black-out), the actuators are provided with a manual release system.
Warning: to operate the manual release system is required to operate on the actuator witch is installed inside the property, it is therefore advisable to provide an indipendent pedestrian entrance.
CHECK PAGE 4 to see all actuator’s models and overall dimensions
CHECK PAGE 5 to see the comparison table witch contains all technical data
2. SAFETY WARNINGS
Warning ! READ AND FOLLOW ALL INSTRUCTIONS. DUCATI door openers have been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict accordance with the instructions and warnings contained in this manual. Failure to meet the requirements stated in this instruction manual could cause severe injury and/or death, for which the manufacturer cannot be held responsible.
SAVE THIS INSTRUCTION MANUAL
Make sure everyone who’s using or will be using the gate door opening system is aware of the dangers associated with this system. In case you will sell the property with the gate opener, Provided for copy of this manual to the new owner.
WARNINGS:
• Before starting the installation, check whether the product is suitable to automate your gate. If it is not suitable, DO NOT proceed with the installation.
Before installation:
Understand your new Door Opening system:
- Read this instruction manual in advance to thoroughly understand its function and features.
- Verify that this door opening system is proper for the type, size and weight of your door.
- Check the state of your door:- Make sure that your door has been properly installed and is functional.
- Check the structure of the door, walls or pillars: they must be sound and stable.
- Make sure your door is properly balanced and lubricated. An unbalanced door could cause serious injury or death!
- If the door binds, sticks or is out of balance, always call a trained, certified door systems technician to prevent serious injury or death.
24
During installation
Ensure your personal safety:
- Never wear watches, rings or loose clothing while installing or servicing the opening system.They could get caught in the door opener mechanisms.
- High voltage wiring (110V-230V power) must be done exclusively by a competent professional and certified electrician.
Prevent serious injury or death:
- Be careful when manipulating with moving parts and avoid close proximity to areas where fingers or hands could be pinched.
- Use concrete anchors when installing any brackets into masonry.
- Do not activate your door opening system unless you are sure that the area of its travel is clear of persons, pets or other obstructions.
Watch the door through its entire movement. Never leave childrens without parental control in proximity of a gate opener in motion , opened, clo-sed or stopped.
- Never permit children to play with remote control push buttons or transmitters of gate opener and prevent childrens to operate the gate opener by control push buttons or transmitters.
- Always keep remote controls out of reach of children.
- Install the electronic box of your opener out of reach of children and away of moving parts of the gate.
- Activate the gate only when it can be seen clearly, is properly adjusted and there are no obstructions to door travel.
- Always keep gate in sight until completely closed.
Prevent damage of the opening system and reduction of its safety features:
- The motor fixing brackets must be rigidly fastened to the pillar and to a well reinforced part of the gate.
- Never increase force beyond minimum amount required to close the gate door.
- Never use force adjustment to compensate for a binding or sticking garage door. After any adjustment is made, the safety system must be tested.
After installation
Verify correct installation:
- Upon completion of installation, test to make sure that your door opening system is working correctly, and test the safety system.
- The door must stop when it contacts an obstacle.
NOTE: CE safety rules. To be tested after installation and after each setting by a dynamometer.Max. pressure on obstacle: 400N and must decrease to max.100N within 0,75seconds and decrease to 0,0N within 1 sec.( UNI EN 12453-EN12445) This measurement must be taken and tested 30cm/10cm and 5 cm from closed gate position.
- The safety system could fail if the door opener is not correctly installed.
- Verify power adjustment and settings after installation.
- Ensure that the parts of the door do not extend over public foothpath or roads
- Install any fixed control at heigh of at least 1,5m and within sight of the door but away from mooving parts
- Make sur you have a second pedestrian access to your property.
Remember: in case of power failure or any problem with your opener you might be unable to operate it from outside your property
- Save the unlocking key in a safe place out of reach of childrens, in order to permit to manually unlock
(from inside) the gate and operate it manually in case of power failure or other problem.
Ensure safety and prevent injuries:
- Place warning labels on the wall next to door control. permanently fix a label warning against entrapment in a prominent place or just near any fixed control
- Without a properly working safety system, people (particularly small children) can be SERIOUSLY
INJURED or KILLED by a closing door. After installation ensure that the mechanism is properly adjusted.
- Never permit anyone to cross the path of a closing garage door. No one should go close to a stopped, partially open door.
- Never leave children unsupervised near a door opener, whether moving, open, closed or stopped.
- Never permit children to play with the door opener’s remote control buttons or transmitters, and do not allow children to use them to operate the door opener.
Always keep remote controls out of reach of children.
- Install wall-mounted door controls (optional) out of the reach of children and away from moving parts of the door.
- Always keep the door in sight until completely closed.
- While the door is closing, do not attempt to stop it by hand. This is extremely dangerous.
MOUNTING HARDWARE:
To compleete the installation you need following material:plastic hammer; pinching for Seeger; level; Cross screwdriver PH2; flat screwdriver 2,5 mm; adjustable wrench; electric cable H07NRF length according to the connection of the two actuators to the control box; 4 bolts for fixing plates with the gate with a diameter
8 mm length according to the thickness of the-gate; 4 bolts for fixing plates with the pillar with a diameter
8 mm length according to the thickness of the pillar; pinching; vice; cable clamp. Cables for additional connections (0,5mm2)Prepare all the tools and material of use necessary to the installation. Tools must be in perfect state and in conformity with the safety rules indicated by the national law.Prepare and install an insulated underground ICT25 mm shealth to pass the actuator cable ( 2 X 1 mm2) to the contol box as well as the photocells cables.
WARNING: READ AND UNDERSTAND PAGE 4:
Pillar dimension, how to determinate measure A & B in case of gate opening towards inside or outside, Gate stop limits.
For installation on gates opening to the outside, you need to use telescopic actuators and install referring to the mounting scheme of fig.12 on pg. 6. Remember that with a gate opening towards the outside is necessary to reverse the polarity of the motor cables (blue/brown cable). Check the feasibility of such a system taking into account the overall dimensions. Make sure that the gate do not open onto a public passageway. It is advisable to prepare a plant with safety photocells to be placed in such a way that the doors, opening towards the outside do not create damages to things and people who are on the outside of the property, such as parked vehicles.
4. POST MOUNTING BRACKETS (read carefully page 4)
4.1 – Pillar/ Coloumn/ fence post: determinate the position where to install the post mounting bracket
According to the actuator model, and to the pillar dimension, calculate the ideal fixing position of the rear bracket by consulting the installation schema of your actuator’s model
HC312............page 5 HC418............page 9 SW400............page 12
HC412............page 6 HC518............page 10 SW400T..........page 13
HC512............page 7 HC618............page 11
HC612............page 8
EVO 700............page 14 EVE 900 FC...............page 16
EVO 700T .........page 15 EVE 900 T FC............page 17
The post bracket fixing position is extremely important as it shall determinate the gate opening angle and speed and actuator thrust strenght. See the limit measures “A and “B”
Remind: with a high “B” measure, the opening will be slower. To fix the plate on the pillar use anchors accordingly to the pillar construction material.
Take into account that the actuator must be installed perfectly horizontal and at a height such that the front fixing plate corresponds to a reinforced area of the gate. It is recommended to install the actuator not less than at 15cm from the ground.
Important! to allow a linear movement of the automation A & B measures should be similar.
Warning: if the structure is impossible to comply with the dimensions stated in the table ( ex. big masonry pillar ), you will need to carry out masonry works to allow the correct positioning of the actuator.
3. GENERAL INSTALLATION SCHEME ,PILLAR DIMENSIONS & STOP LIMITS
The diagram on page 3 shows an example of a typical automatic system.
Referring to this diagram, determine the approximate location where you will install each component envisaged in the system and the most appropriate connection diagram.
The motors are to be connected with outdoor pole cable type H07NRF min. 0,75mmq
The accessories are connected with a bipolar outdoor cable min.0,35mmq
Useful components for an ideal automatic system:
1= Control box with containing electronic board with on board radio receiver, toroidal transformer, inner battery compartment.
2 = actuators
3 = blinking light
4 = external antenna
5 = key switch
6 = radio remote control
7 = radio keypad
8 = solar panel
9 = pair of photocells ( receiver + transmitter)
4.2. FIx the bracket to the Pillar/ Coloumn/ fence post
Each actuator model is provided with specific brackets.
Mark middle of post bracket slots on pillar/ coloumn/ fence post.
Fix the bracket on the pillar. Use bolts anchors or screws suitable for the structure (tubular iron / pillar masonry / concrete)
4.3 FIx the actuator to the post bracket:
Fasten the actuator to the bracket of the rear fixing with the pin and seal ring
- for EVE actuators see pag..19
- for “HC” actuators see pag.20
- for “SW” & EVO actuators see pag.21
25
D U C A T I A c t u a t o r ’ s i n s t a l l a t i o n i n s t r u c t i o n s
5 – FRONT MOUNTING BRACKET
5.1 How to determinate the position where to install the front mounting bracket
Warning:
telescopic actuators are supplied with telescopic tube are provided with totally retracted piston, therefore the fixing position of the front bracket to the gate must be determined with the gate in open position. resume of telescopic actuators models:
HC312; HC412; HC512; HC612; SW400T; EVOT900; EVE900T (+ corresponding 24V versions)
NON telescopic actuators are provided with the fixing pin plate positioned to the front, therefore the fixing position of the front bracket to the gate must be determined with the gate in closed position. resume of NON telescopic actuators models:
HC418; HC518,HC618, SW400; EVO900; EVE900 (+ corresponding 24V versions)
5.2 Fix the front bracket to the gate
- The actuator must be fastened to the port fixing bracket, keep it perfectly horizontal,
- bring the actuator to the gate leaf and identify the fixing point of the front plate to the wing gate.
- Mark middle of front bracket slots on the gate wing.
- Fix the bracket on the gate. Use bolts anchors or screws suitable for the gate ( wood/ iron/...). It ‘also possible to weld the bracket to the wing of the gate.
- Fasten the actuator to the bracket. Fix it with the pin and seal ring
- for EVE actuators see page 19
- for “HC” actuators see page 20
- for “SW” & EVO actuators see page 21
6. MANUAL RELEASE
The actuators are equipped with a release system which allows the manual handling of the gate in case of emergency.
The release system is operated through the use of three-sided key that must be inserted into the triangular slot.
Turn of about 40 ° up to the stop in a counterclockwise direction. The engines will be unlocked and the doors will be moved maualmente.
The reverse operation will restore the automatism traction.
Warning! perform the manual release only once the actuator is installed to the gate.
- for EVE actuators see page 19
- for “HC” actuators see page 20
- for “SW” & EVO actuators see page 21
For “EVE” acuators the optional “ EVE LOCK” manual release key protected accessory is also available. see page 19 fig. 15B
For “SW & EVO acuators the optional “ SW LOCK” manual release key protected accessory is also available. see page21 fig.26B
26
7 - MECHANICAL LIMITS
It is reminded that,with exhemption in case of use of actuators featured with integrated mechanical or electrical limits, it is mandatory to install mechanical gate stop limits to be firmly placed to the ground in correspondance to gate closed and open position. ( see page 4) The gate operator stops running by amperometric detection when the door detects and presses on the mechanical stop.
FC actuator versions are equipped with integrated mechanical limits: checkpage 18 technical data table.
for FC actuator versions, where the on-board limit is provided, it is not mandatory to have gate stops fixed to the ground.
7.1 on board mechanical limits adjustment ( for FC actuator’s versions only)
- Release the actuator
- Manually place the gate wing in the open desired position. hold the gate in the desired position.
- Loosen the on-board mechanical stop screw with an Allen key
- Slide the on-board mechanical stop along the large screw until it goes into contact with the nut screw (or sliding shoe plate)
- stop & firmly tighten the limit switch by fastening the grains using an Allen key.
- you can repeat the same procedure to adjust the second limit and set it for the gate leaf closed position.
7.2 on board electric limits adjustment (for EVE series in the “FCA” versions only)
Models: EVE in the “FCA” versions are equipped with 2 electric limits. To adjust the position of the limit switches use a flat screwdriver through the holes positioned in the front of the actuator. By turning the screws, you will adjust the electric lim it along the stroke of the rod. The limits position is indicated on the side of the actuator by special marker
8. FINAL CONTROL OF CORRECT INSTALLATION
Once the actuator is installed , it is recommendetd to check that it is set perfectly horizontal and is well balanced.
- Unlock the actuator and perform a manual maneuver to verify that there are no points of greatest friction along the stroke.
-The gate wing must move without effort.
- The gate wing must stop on the mechanical gate limit (or, where provided, on the o- board limits)
9. MAINTENANCE
The actuators do not require any maintenance.
Only as a precautionary measure and in case of intensive use you should check the integrity of the electrical cable connected to the motor
WARNING: NEVER USE GREASE LUBRICATE THE MECHANICAL PARTS!
D U C A T I C o n t r o l b o x e s & w i r i n g
2. PREPARATIONS
Prepare the insulated cable ducts for motors and accessories wires (not supplied). Prepare the power plant to the location where you intend to attach the control unit (not necessary in the case of self-powered SOLAR PANEL powered openers) Warning: the power of the high-voltage current must be managed exclusively by a specialized technician.
Do not manage yourself the power supply connection 230 / 110V: Danger of Death!
Caution: it is recommended to prepare a disconnection device to be used in case of emergency. Warning: the control unit and activation commands must be installed in a not acessible place and at a height from the ground, not allowing the use by unauthorized persons or children.
13.CONTROL BOX INSTALLATION
Fix the bottom of the control unit to the wall or pillar using apropriates screws and plugs (not supplied). It is advisable to seal any holes to prevent water infiltration, moisture, dust and insects. It is recommended to provide appropriate compression sleeves (not supplied)
Small control box KONTROL” Small” see pic.39 Large control box KONTROL”Largel” see pic.40 The control Kontrol “Large” is equipped with a inner protective cover underneath witch are inseted the electronic board and the toroidal transformer.
39
K o n t r o l ” m i n i ”
“ S m a l l s i z e ” k o n t r o l b o x
120 mm
A
40
K o n t r o l
“Large size” control box
180 mm
120 mm
B
A
B
120 mm
27
D U C A T I M a i n A C p o w e r s u p p l y
14. MAIN POWER SUPPLY 230V / 110 V
The main power supply high voltage 230V (110V on request) connection must be performed only by a licensed electrician! Warning: danger of death.
The power cable is connected to the terminal block / fuse protection upstream of the toroidal transformer (pic.41)
The transformer is already connected to the PCB. Check for proper connection.
Connect cables from the transformer to the circuit board. Remember:
The transformer has 3 ouput cables, but for 12V motors only balck and yellow cable must be connected. while red cable (24V must be used in stead of yellow cable only for 24V motor versions)Black =0 + Yellow=
12V to be used for 12V motors
Black =0 + Red= 24V to be used for 24V motors
Solar panel powered openers do not require any high voltage connection .Nevertheless, they are always provided with a toroidal transformer and in case of emergency or to recharge the battery the main voltage
230V (110V on demand)can be connected to the terminal block / fuse protection upstream of the toroidal transformer (pic.41)
41 42
Main electronic board
YELLOW
12V
WARNING! To prevent damage during shipment, the transformer could be provided not pre-installed in the control panel. it is supplied with a fixing cone and screw to fix it to the bottom of the the control box.
See pic. 39/ 40: Place the transformer in it’s correct position (A) and fix it to the bottom of the control box unit using using the special cone support and crew it.
Fix the power supply 230V / 110V connectors terminals with protection fuse in the position (B) of the bottom of the control bozx unit ( see pic. 39-
40).
Connect cables from the transformer to the circuit board. Remember:
The transformer has 3 ouput cables, but for 12V motors only balck and yellow cable must be connected. while red cable (24V must be used in stead of yellow cable only for 24V motor versions)
Black =0 + Yellow= 12V to be used for 12V motors
Black =0 + Red= 24V to be used for 24V motors
28
TRASFORMER
Protection fuse:
230V - 0,8AT
110V - 1,2AT
A . C .
230V 50H /
(110V 60Hz)
D U C A T I e l e c t r o n i c b o a r d
C T H 4 1 “ E n t r y l e v e l ”
7851
Small Control Box with CTH41
120 mm
CTH41
Electronic board
TECHNNICAL DATA
Power supply (on demand
Use on 2 wings gate
Use on 1 wing gate
Automatic protection fuse
Transformer protection fuse
Toroidal transformer’s Watt
Output services
Power consumption in stand-by
Radio receiver (channel)
Remote control storage capacity
Radio transmission protocol
Remote control automatic learning
On board Antenna
Automatic closure function ( timerized)
Anti-pressure safety system
Safety beam/ Photocells input
Full cycle START (NO contact)
Flashing light output
Gear anti-pressure system
CTH41 CTH41 MONO
230V ( 110V on demand)
√ -
-
√
0,8A T ( 1,2A T )
80W
12V
15mA
1
√
10
Ducati rolling code 433MHz
√
√
√
√
√ NC
√ NO
12V max 10W
√
Compatibles accessories
SW7012
29
30
D U C A T I e l e c t r o n i c b o a r d
C T H 4 1 “ E n t r y l e v e l ” trasformer
12V 0
230(110V)
CTH41
Connections and adjustments:
ATTENTION ! all settings have to be made with gate in closed position
CONNECTORS:
1/3 (STR) START contact NO full cycle opening
2 (FTC) Photocell NC contact (FTC)
3 (COM) Common ( start &photocell)
4 (POS) + power photocell positive 12V dc
CTH41
8 M2 actuator blue cable
9/10 12V 10W max. blinking light
Photocells bridge: between connectors 2/3
Remove the bridge only when connecting the photocells.
The phase shift between the 2 wings is automatically set and can not be modified.
FTC
NC
START
M1 M2
PUSH BUTTON:
P1 = FULL CYCLE push button to store or cancel the radio transmitters codes on the electronic board.
This button is used to set complete opening cycles. Red LED visual indicator.
Remote controls setting: to syncronize a remote control channel:
On the main board Press P1 to memorize a remote control Channel for compleete opening cycle.
Release P1.
As the red LED turns on, push the selected radio remote control button. After the red LED blinks, wait until the red LED turns off. Operation completed.
Maximal storage capacity: 10 channels
To delete the stored channels press P1 for about 30 sec. until the red LED turns off.
All remote control codes will be delated.
the electronic board is set on “STEP by STEP” working mode.
with this setting a pulse controls the opening and a second impulse closes the gate.
How to set the automatic closure function(the pause time before the gates automatically closes is
30seconds and cannot be adjusted):
1- cut off the power to the board and wait for 5 seconds
2- keeping P1 key pressed, power the board.
Operation performed.
Following the same procedure you will return to the step by step operating mode.
CTH41 MONO
special version for use on single wing gate: only connect M1. Ohter connections remain the same
D U C A T I e l e c t r o n i c b o a r d
C T H 4 2 “ S t a n d a r d l e v e l ”
CTH42
Electronic board
180 mm 120 mm
7855
Complete Large size control box with CTH42
180 mm
P1 P2
120 mm TECHNNICAL DATA
Power supply (on demand)
Use on 1 or 2 wings gate
Protection fuse
Transformer protection fuse
Toroidal transformer’s Watt
Output services
Power consumption in stand-by
Radio receiver (channel)
Remote control storage capacity
Radio transmission protocol
Remote control automatic learning
On board Antenna
External antenna input
Automatic close function ( timerized)
Anti-pressure safety system
Motor power adjustment
Timerized Courtesy light contact
Output for elecktrolock
Safety beam/ Photocells input
Full cycle START (NO contact)
Pedestrian cycle START ( NO contact)
Flashing light output
Output to optional battery charger module(CMBAT)
LED indication of Power supply
Gear anti-pressure system
CTH42
230V ( 110V on demand)
√
√ 10AF
0,8A T ( 1,2A T )
105W
12V
22 mA
2 channels
10
DUCATI rolling code 433MHz
√
√
√
0-100 sec.
√
√
√
12V dc
√
√
√
12V max 10W
√
√
√
Compatibles accessories
Pult
6203R
Pult
6203P
Pult
6204
Pult
6206
Tasty
6704
SW
6504
Rixy
6043
KEY
5000
KEY
5001
E-LOCK booster
LASER
7012
SW7012 LASER
100
STILO
6025
FLASH
7712
FLASH
7512
HC
7512
KB
900
CMBAT** BAT
1012
31
D U C A T I e l e c t r o n i c b o a r d
C T H 4 2 “ S t a n d a r d l e v e l ”
Connections and adjustments:
ATTENTION ! all settings have to be made with gate in closed position
CONNECTORS:
0= step by step max100 sec. automatic closure trasformer
12V solar panel
230(110V)
8/9 START contact NO for pedestrian opening cycle
10 + power photocell positive
11 - power photocell negative
12/13 12V 10W max. blinking light
Time Power
M1
Power
M2
12V 0
17 M1 actuator brown cable
18/19 output for garden/courtesy light
(contact NO/NC max 0,5A) use a relay if ac
20/2112V ac electrolock output
1
2
T1
JP1
T2 T3
CTH42
-
CMBAT
to board
sol -
sol +
FTC
NC
START
J1
START
Pedonale
12V
10W max
+ photocells
A)
Garden courtesy timerized light
12V max 10W
B)
Garden courtesy timerized light powered by 230V /110V
AC versa during closing.
Photocells bridge: between connectors 4/5
Remove the bridge only when connecting the photocells.
Red LED:
- indicate the procedure to memorize/delete remote ontrols codes
- while gate is open: it blinks if the automatic closure has been activated
Green LED:- if steady on = the board is powered
M2 M1 courtesy timerized light
12V ac
electrolock output
A)
PUSH BUTTONS P1; P2; J1
P1 = FULL CYCLE push button to store or cancel the radio transmitters codes on the electronic board.
This button is used to set complete opening cycles. Red LED visual indicator.
J1 = PEDESTRIAN ACCESS push button to store or cancel the radio transmitters codes on the electronic board. This button is used to set pedestrian opening cycles (partially activates only the door corresponding to the motor M1 only ). Visual indicator: red LED visual indicator.+ yellow LED, then only red LED.
Remote controls setting: to syncronize a remote control channel:
On the main board Press P1 to memorize a remote control Channel for compleete opening cycle.
Release P1.As the red LED turns on, push the selected radio remote control button. After the red LED blinks, wait until the red LED turns off. Operation completed.Maximal storage capacity: 10 channels
To delete the stored channels press P1 for about 30 sec. until the red LED turns off.
All remote control codes will be delated.
POTENTIOMETERS
P2 =deactivate/activate the Gear anti-pressure system ( with the anti-pressure-system activated the gate reaches the mechanical limit it will invert the direction for 0,25sec to release pressure on wing inghes and actuator’s gear). This function is automatically set in the board. To delete this feature, proceed as follows: press
P1 for 1 second. the red LED lights. Press P2 for a second. function deactivated. To restore the function, repeat the procedure.
TIME = potentiometer to set the “step by step” mode of use or automatic closure
The potentiometer completely turned counterclockwise( position = 0 ) to use the standard setting “step by step” mode of use. with this setting a pulse controls the opening and a second impulse closes the gate.
By rotating the potentiometer clockwise, you will set the automatic closure function.Turning the knob increases the time. Maximum pause time = 100 seconds with potentiometer fully clockwise.
JP1 SWITCH
JP1 switched on position 1= 1 wing gate use
JP1 switched on position 2= 1 wing gate use
32
POWER M1: actuator M1 power /obstacle detection sensitivity adjustment
POWER M2: actuator M2 power /obstacle detection sensitivity adjustment
Turn the potentiometer clockwise to increase power and reduce obstacle detection sensitivity
D U C A T I e l e c t r o n i c b o a r d
C T H 4 4 “ f u l l s o l a r ”
180 mm 120 mm
0= step by step max100 sec. automatic closure
FULLSOL SYSTEM
Operators specifically dedicated to solar panel power supply (230V main AC power supply is possible by mantaining connected the battery)
Time Power
M1
Power
M2
T1 T2
P1 P2
T3
CTH44 switch
A B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
FTC
NC
START
12V
10W
M1
+12 NEG
J8
M2
+
solar panel
+
-
+
+12V photocells
-
to 12V batt
2° solar panel to transfo
12V 0
230(110V)
P1 P2
SWITCH
ON switch 1
ON switch 2
TECHNNICAL DATA
Power supply (on demand)
Solar panel power supply
Use on 1 or 2 wings gate
Protection fuse
Transformer protection fuse
Toroidal transformer’s Watt
Output services
Power consumption in stand-by
Radio receiver (channel)
Remote control storage capacity
Radio transmission protocol
Remote control automatic learning
On board Antenna
External antenna input
Automatic close function (timerized)
CTH44
230V ( 110V) + 12V battery / solar panel + battery
√
√
√
√ 0,8AT (1,2AT)
105W
12V
10,6mA
2 channels
10
DUCATI rolling code
433MHz
√
√
√
√
Anti-pressure safety system
Motor power adjustment
Safety beam/ Photocells input
Full cycle START (NO contact)
Flashing light output
Battery output with on boad battery charge management by flashing light
√
√
√ mod 7120
√
12V 10W
√
√
√
Gear anti-pressure system
LED indication of Power supply
LED segnalazione stato batteria
√
√
√
√
√
√
33
D U C A T I e l e c t r o n i c b o a r d
C T H 4 4 “ f u l l s o l a r ”
Connections and adjustments:
ATTENTION ! all settings have to be made with gate in closed position
ATTENTION ! in case of use use with power from photovoltaic panel use low consumption photocells mod. 7120 only!
WARNING: it is mandatory to have the battery full charged before to power the electronic board. Charge the battery before use. To charge the battery: a) Use the supplied 12v transformer, connect it to the board ( yellow-black cables), connect the battery to the borard first (respect polarity red cable= + positive / black or blue cable= -negative), connect a electric wire min.0,75mmq to the terminals downstream of the transformer. Plug the electric wire to a power outlet. b) Use a battery charger with charge control (ex. our optional battery charger MPBAT). respect polarity. whait until the battery is fully charged ( green LED on MPBAT is steady on).
You must check the battery charge status by the control board:see herunder P2 procedure
SWITCH 2 * = switch it ON ( upper position) activates the check for better solar panel positioning
REMEMBER: Perform this operation between noon and 2:00 p.m.
warning: switch 1 must be OFF ( lower position)
To find the better solar panel aligniment, check if the green LED on the control panel is on. Meanwhile, the acoustic signal must emit a continuous BEEP to show that the solar panel is in a good position. If the acoustic signal is intermittent and the red or yellow LED is on, it means that in this position exposure is inadequate for charging. In this case, move the panel into other attachment positions until you find a good one. Solar panel must always be positioned toward south. Once finisched the procedure, put the switch 1 OFF ( lower position)
PUSH BUTTONS P1; P2;
P1 = FULL CYCLE push button to store or cancel the radio transmitters codes on the electronic board.
This button is used to set complete opening cycles. Red LED visual indicator.
P1 + P2= PEDESTRIAN ACCESS push button to store or cancel the radio transmitters codes on the electronic board. This button is used to set pedestrian opening cycles (partially activates only the door corresponding to the motor M1 only ) to memorize a remote control push button to command the pedestian opening cycle: press P1, hold P1 pressed, press P2. release P1 and P2, then press the remote control push button and hold it
CONNECTORS:
A/B antenna / sock
1/3 START contact NO full opening cycle
2 FTC photocells NC contact (to be connected to terminal 3 of low consumption photocell model RX 7120)
7/8 12V 10W max. blinking light
9 M1 actuator brown cable (note: M1 is the motore installed on the wing that opens first)
10 M1 actuator blue cable
11 M2 actuator brown cable
12 M2 actuator blue cable
13 + 12V solar panel positive
14 - 12V solar panel negative
15 + 2° solar panel positive ( the use of a 2° 12V solar panel is not mandatory)
16 - 2° solar panel negative
J8: +12 + power photocell positive
NEG - power photocell negative pressed for about 4 seconds unil the red LED confirm the remote control push button has been stored.
P2 = BATTERY CHARGE STAUS CHECK the battery must be connected to the board. ( check the correct
polarity) Press and hold the P2 button to check the battery charge status, viewing the color of LED lights.
Make sure that green LEd is on, otherwise proceed to a full battery charge. If the battery is discharged, the system goes into a protection state and will stop working. outcome of a new control tests. it will be necessary to repeat the checking procedureuntil the the battery is checked to be fully charged ( green LED on) nthis way the board will be restored.
Red LED on +Sound Buzzer = Low battery: the voltage is lower than 11,2V yellow LED ON = Battery partially discharged: the voltage is between 12.4 and 12.9V
Green LED on = Battery charged: the voltage is greater than 12.9V.
Warning: It is possible to power the board by 230V/110V (trough the transformer) instead of by solar panel, but the battery ust be always keeped connected to the board.
The phase shift between gate wings is automatically set. M2 follows M1 in opening after about 3 sec. and vice versa during closing.
Warning: Photocells bridge: between connectors 2/3.
Remove the bridge only when connecting the photocells.
Green LED =indicates the batery is fully charged
Red LED= indicates:-full cycle remotes control storage procedure/ the battery is out of charge/ blinking while the gate is open indicates the automatic closure working mode is settled.
Yellow LED=indicates:
-pedestian opening cycle remote control storage procedure
- battery is almost discharged
SWITCH 1 = switch it ON ( upper position) activates the ACOUSTIC and LED GUIDED PHOTOCELLS
ALIGNMENT SYSTEM
Connect the low consumption 7120 photocells to the electronic board. Put the photocell’s alignment switch (No. 1) in the up position. Try to align the protocell receiver to the photocell transmittent following the acoustic and LED signals until you obtain a perfect alignment.
Long “BEEP” = CORRECT ALIGNEMENT = on the board the green LED is ON intermittent “BEEP-
BEEP-BEEP”= NOT ALIGNED = on the board red or yellow LED is ON. When the alignment procedure is finished, put the alignment switch (1) back to the down position; otherwise the system will not operate.
34
Remote controls setting: to syncronize a remote control channel:
On the main board Press P1 to memorize a remote control Channel for compleete opening cycle.
Release P1.As the red LED turns on, push the selected radio remote control button. After the red LED blinks, wait until the red LED turns off. Operation completed.Maximal storage capacity: 10 channels
To delete the stored channels press P1 for about 30 sec. until the red LED turns off.
All remote control codes will be delated.
POTENTIOMETERS
TIME
= potentiometer to set the “step by step” mode of use or automatic closure
The potentiometer completely turned counterclockwise( position = 0 ) to use the standard setting “step by step” mode of use. with this setting a pulse controls the opening and a second impulse closes the gate. By rotating the potentiometer clockwise, you will set the automatic closure function.Turning the knob increases the time.
Maximum pause time = 100 seconds with potentiometer fully clockwise.
POWER M1: actuator M1 power /obstacle detection sensitivity adjustment
POWER M2: actuator M2 power /obstacle detection sensitivity adjustment
Turn the potentiometer clockwise to increase power and reduce obstacle detection sensitivity
Use on single wing gate: connect motor M1 only.
D U C A T I
E l e c t r o n i c b o a r d
C T H 4 8 D U C O S O L t e c h n o l o g y & S O F T S T O P
CTH48
180 mm 120 mm
P1 P2
TECHNNICAL DATA
KONTROL 9048
Complete Large size control box with CTH48
Power supply (on demand)
DUCOSOL SYSTEM
Versatile, operates by 3 type of power supply without any additional modules required:
1) A.C. 110/230V 60/50Hz
2) by emergency battery
3) By solar panel
Solar module power supply
Use on 1 or 2 wings gate
Protection fuse
Transformer protection fuse
Toroidal transformer’s Watt
Output services
Power consumption in stand-by
Radio receiver (channel)
Remote control storage capacity
Radio transmission protocol
Radio receiver self learning
On board Antenna
External antenna input
Automatic close function ( timerized)
Anti-pressure safety system
Motor power adjustment
Reverse movement on obstacle detection
Electric limit switch input
Courtesy light contact
105V
√ 12V
√
√
√ 0,8AT (1,2AT)
CTH48/24
24V solar panel
√ 24V
12V 24V
0,007A
2 channels
20
DUCATI rolling code 433MHz
√
√
√
√ ( 1-100 sec)
√
-
√
√
√
12V dc output 24V dc output
Compatible accessories
Elektrolock use while power by solar module/ battery
Safety beam/ Photocells input ( NC contact)
Full cycle START output (NO contact)
Pedestrian cycle START output ( NO contact)
Emergency STOP button (NC contact)
Flashing light output
Output to battery with on board charger
Indication of battery charge status by blinking light solar panel input
LED indication of Power supply
Slowdown ( soft stop)
Gear anti-pressure system wings time lag adjustment
Status indicator output (open, closed, moving)
√ with additional booster only
√12V
√
12V max 10W lamp
√
√
√ 12V
√
√
√
√
√
√
√
√ 24V
24V max 10W
√ 24V
6700
6704
6500
6504
6040
6043
1012+ booster
SW7012
6023
6025
7500/12
7512
900KB
900
BAT
1012
SOLAR
1020
MPBAT
35
D U C A T I
E l e c t r o n i c b o a r d
C T H 4 8
ATTENTION:
USE OF PHOTOCELLS ON CTH48
It is highly recommended to use original DUCATI photocells only.
Use only low consumption photocells model 7120 in case of solar panel power supply.
It is recommended to use photocells model DUCATI 7012 in case of standard supply by 230/110 V
For different needs first contact our technical department before connecting any non original photocells model.
Attention: If photocells are connected take out the photocells bridge between connectors
6 & 7
TX (photocell transmitter
Same for both 7120 & 7012
1 (+) connect to n° 9 on CTH48
2 (-) connect to n° 10 on CTH48
RX (photocell model 7012 receiver)
1 (+) connect to n° 9 on CTH48
2 (-) connect to n° 10 on CTH48
3 (COM) common connect to n° 7 on CTH48
4 FTC (photocell contact NC) connect to n° 6 on CTH48
RX (photocell model 7120 receiver)
1 (+) connect to n° 9 on CTH48 on 9
2 (-) connect to n° 10 on CTH48
3 FTC (photocell contact NC) connect to n° 6 on CTH48
4 not to be used
0= step by step max100 sec. automatic closure
TIME SENS SLOW/ ARS
WARNING: start installation with potentiometers positioned as follows:
TIME: rotated anticlockwise
SENS: rotated clockwise
SLOW: rotated anticlockwise transformer
230(110V)
T1 switch
T2 T3
CTH48
FUSE
10AT
5 x 20
12V 0
-
ON switch 1
:
Use on 2 wings gate
OFF
Use on 1 wing gate
ON switch 2
:
FAST
To deactivate
SOFT STOP &
Obstcle reversal system
OFF
To activate
SOFT STOP &
Obstcle reversal system
ON switch 3 :
START full cycle
FTC
NC
STOP
START
Pedestrian
+ photocell
-
-
+
Solar panel
12V
M1 M2
12V 10W blinking light
12V dc
electrolock output
Booster electrolock switch 4
:
ON
OFF
OFF
STATUS
GATE STATUS remote indicator light 12V max 10W lamp
A) Garden courtesy max 10W
B) Garden courtesy timeri-
/110V
AC
K
RELAYS
36
D U C A T I
E l e c t r o n i c b o a r d
C T H 4 8 D U C O S O L t e c h n o l o g y & S O F T S T O P
SWITCH 1 on ON = use on single wing gate and connect the motor as M1
ON
OFF
ON
FAST
OFF
SWITCH 1 on OFF = use on double wing gate
ON SWITCH 3 on ON only if coombined with automatic closure ( potentiometer T1 must have been turned clockwise to activate the automatic closure function) will enable:
OFF
ON
OFF
STATUS
SWITCH 4 on ON : active courtesy light / garden light lighting time 20sec.
A1) NO dry contact becomes NC to activate a small 12V bulb max.10W
B1)a relay for any lighting system of higher power. 12V 10W max output terminals 17 -18
A1) courtesy light 12V max 10W
A2) remote gate status signal
remote gate status signal
12V max 10W lamp
B1) Garden Light powered by
220/110V /110V AC
K
RELAY
B2 ) ONLY 3 wires to get remote gate status signal and a wired command to keep the gate open
T1 switch Keep the gate open
START
remote gate status signal
12V max 10W lamp
37
D U C A T I
E l e c t r o n i c b o a r d
C T H 4 8 & p h o t o c e l l s 7 1 2 0 o r 7 0 1 2
ATTENTION: PHOTOCELLS ON CTH48
It is strictly recommended to use original DUCATI photocells only.
Use only low consumption photocells model 7120 in case of solar panel power supply. no other model is compatible.
It is recommended to use photocells model DUCATI 7012 in case of standard supply by 230/110 V
For different needs first contact our technical department before connecting any non original photocells model.
RX (photocell model 7012)
1 (+) connect to n° 9
2 (-) connect to n° 10
3 (COM) common connect to n° 7
4 FTC (photocell contact NC) connect to n° 6
1 (+) connect to n° 9
2 (-) connect to n° 10
RX (photocell model 7120)
1 (+) connect to n° 9
2 (-) connect to n° 10
3 FTC (photocell contact NC) connect to n° 6
4 DO NOT USE !
Attention: If photocells are connected take out the photocells bridge between connectors 6 & 7
CTH48
FTC photocells NC contact
COM photocells common
- photocells negative power output
+ photocells positive power output
38
PHOTOCELLS MODEL 7012 ( AC/DC 12V/24V): how to connect double pair of photocells:
+
-
+
-
COM
TX
RX
FTC (normally closed contact)
TX
+
-
+
-
COM
RX
FTC (normally closed contact)
COM
+ -
FTC
LOW CONSUMPTION PHOTOCELLS MODEL 7120: (DC 12V/24V) how to connect double pair of photocells:
+
-
+
-
FTC
RX
TX
DO NOT USE
TX
+
-
+
-
FTC
DO NOT USE
RX
FTC
+ -
D U C A T I
E l e c t r o n i c b o a r d
C T H 4 8 D U C O S O L t e c h n o l o g y & S O F T S T O P
CTH48 featuring DUCOSOL system
Connections and adjustments:
ATTENTION ! all settings have to be made with gate in closed position
ATTENTION ! in case of use use with power from photovoltaic panel use low consumption photocells mod. 7120 only!
CONNECTORS:
1/2 antenna / sock
3/4 START NO complete cycle
4/5 START NO pedestrian opening
6 Photocell NC contact (FTC) to be connected to terminal 3 of the photocell 7120 and / or 7012
7 Photocell common contact (COM) to be connected to terminal 4 of the photocell 7012. In case of use by
230V power and use of the photocell model 7120 is not used
7/8 NC Contact for safety/emergency STOP ( WARNING: if the contact is not hold closed ( by the bridge or by a NC switch button the gate will not operate as condidering it an EMERGENCY STOP)
9 + power photocell positive
10 - power photocell negative
11 - negative solar panel
12 + positive solar panel
13/14 blue/brown cable motore M1
15/16 blue/brown cable motore M2
17/18 2 possible function can be settled:
A) with switch No. 4 in the “ON” position, connectors n°17/18 become output for garden/courtesy light
B) with switch No. 4 in the “OFF” position connectors n°17/18 become output for gate status light indicator.
Connect one bulb 12V 10W max.
light on indicates the gate is open light off indicates the gate is closed
Slowly flashing light indicates the gate is opening
Quick flashing light indicates the gate is closing
19/20 12V dc electrolock output ( to be always used with a booster)
21/22 12V 10W max. blinking light
Photocells bridge: between connectors 6/7
Remove the bridge only when connecting the photocells.
Safety stop bridge: between terminals 7/8.
Remove the bridge only when connected to a NC switch for emergency STOP
DEEP SWITCHES
1: ON positioned= use on double wing gate
OFF positioned= use on single wing gate
2: ON positioned= fast speed only
OFF positioned= soft stop
3: ON positioned= by closing the “START” contact, it will keep the gate opened
4: ON positioned= connectors 17/18 becomes output for garden/courtesy light
OFF positioned= connectors 17/18 becomes output for gate status light indicator
USE ON SINGLE WING GATE
Connect the motor as M1
LED LIGHTS
Red LED:
- indicate the procedure to memorize/delete remote ontrols codes
- while gate is open: it blinks if the automatic closure has been activated
- while gate is open: it stays steady if the “step by step” mode is activated
- flashes if voltage is lower than 10.5V when powered by battery
Green LED
- if steady on = 230/110V powered
- if flashes slowly = battery powered
Yellow LED
- flashes if voltage is lower than 11,5V
Blue LED
Switches on during slow motion phase indicates leaf phase shift procedure in closing:
- get’s on by pushing P3,
POTENTIOMETERS
WORKING MODE: STEP BY STEP or AUTOMATIC
Trimmer 1 (TIME) = potentiometer to set the “step by step” mode of use or automatic closure
The potentiometer completely turned counterclockwise( position = 0 ) to use the standard setting “step by step” mode of use. with this setting a pulse controls the opening and a second impulse closes the gate. By rotating the potentiometer clockwise, you wil set the automatic closure function.Turning the knob increases the time. Maximum pause time = 100 seconds with potentiometer fully clockwise.
MOTOR SENSITIVITY ON OBSTACLE DETECTION ADJUSTMENT
Trimmer 2 (SENS) = Adjust the level of sensitivity in the event of impact on an obstacle during the slow speed phase (SOFT STOP).
trimmer completely rotated counterclockwise = high level of sensitivity in case of impact on obstacle.
Turning the trimmer clockwise decreases sensitivity.
It is recommended to reduce the sensitivity in the presence of wind.
SOFT STOP / ASR auto reversal system ADJUSTMENT
Trimmer 3 (SLOW) = Set the start time of the deceleration phase ( SOFT STOP) and the point where auto reversal system turns to stop function.
Turn the trimmer clockwise to increase the duration of the race at the standard speed (thus to delay the start of the slow speed) Warning: during the first phase the gate will reverse mouvement if detects an obstacle, while in the second phase will stop. In case the gate inverse when reaching the limit stops, you have to rotate potentiometer anticlockwise.
PUSH BUTTONS P1; P2; P3
P1 = FULL CYCLE push button to store or cancel the radio transmitters codes on the electronic board. This button is used to set complete opening cycles. Red LED visual indicator.
P2 = PEDESTRIAN ACCESS push button to store or cancel the radio transmitters codes on the electronic board. This button is used to set pedestrian opening cycles (partially activates only the door corresponding to the motor M1 only ). Visual indicator: red LED visual indicator.+ yellow LED, then only red LED.
P3 =LEAF PHASE DISPLACEMENT push button to adjust the time lag delay displacement between M1 and M2. 39
D U C A T I
E l e c t r o n i c b o a r d
C T H 4 8
HOW TO MEMORIZE/ DELETE REMOTE CONTROL CODE IN THE ELECTRONIC BOARD ( see also remote control chapter)
Remote controls setting: to syncronize a remote control channel:
On the main board Press P1 to memorize a remote control Channel for compleete opening cycle (or press P2 for pedestrian opening cycle).
As the red LED turns on, push the selected radio remote control button. After the red LED blinks, wait until the red LED turns off. Operation completed.
Maximal storage capacity: 20 channels
To delete the stored channels press P1 for about 30 sec. until the red LED turns off. All remote control codes will be delated.
LEAF PHASE DISPLACEMENT
The displacement between wings is automatically settled. In opening cycle, M2 follows M1 after about 3 sec. and vice versa during closing. In case the opening angle of the 2 wings is different ( for. example if one wing opens 90° and the second wing opens 110°) it can be required a leaf phase adjustmentto to avoid the Leafs overlap during closure.
How to adjust the displacement time between the 2 wings:
P3 =push button to adjust the time lag delay displacement between M1 and M2.
M1 = motor on wing gate that opens first
M2 = motor on wing gate that opens as second one.
To change the time lag:
- Press P3,
- the blue LED switches on
- Within 5 seconds, press P1 to reduce the time lag or P2 to increase the time lag
Pressing on P1 the green LED switches on. Pressing P2 LED the yellow LED switches on. Each pulse corresponds to a variation of 0.5 seconds. If the red LED lights, it means that it has exceeded the limit.
Wait 5 seconds without pressing any key to confirm the choice.
Warning: the phase shift programmed is valid for the closing operation only, while the phase shift in the opening is determined by the software and is not editable.
SOLAR PANEL BACK-UP BATTERY POWER SUPPLY
CTH48 do not requires any additional module to manage a back-up battery or solar panel power supply.
For autonomous use in case of power failure - black-out connect directly to the board the back-up battery 12V 7A is recommaded and guarantees about days of autonomous use. battery Connecting cables are ready on board. respect the polarity. red cable = positive; blue or black cable = negative)
For 100% autonomous use by solar panel power supply connect a 12V 7A battery and a solar panel 10W 12V ( if extra autonomy is required connect a 12V 12A battery with a 12V 20W solar panel)
Respect the polarity. terminal 11= negative; terminal 12 = positive. The solar panel must be positioned facing South ( also see solar module chapter)
The herunder table shows the autonomous use guaranteed in worst winter weather by use of a 12V 10W standard solar module & 12V 7A battery. the autonomy capacity higly increase by use of a 12V 12A battery combined with a 20W 12V solar module ( this version is recomanded in case of condominium use or in case of double par of photocells 7120 are installed) control board consumption table
MOTOR
1 wing gate electonic board
CTH44 or CTH48 2 wings gate stand-by consumption/
(A/h) daily standby consumption (A)
0,007 0,16
Full cycle ( open
+ close) consumption (A) hypothesis: daily full cycles total daily consumption
(A)
0,012
0,024
60
50
0,88
1,24
10W solar panel averagerecharge capacity ( A/h) hypotheses: daylight hours
daily in the worst conditions total daily recharge capacity
(A) energy surplus accumulated and not used during the day (A)
0,3 5 1,5
+ 0,62
+ 0,26
40
D U C A T I
R O L L I N G C O D E D R A D I O R E M O T E C O N T R O L S 6 2 0 3 R O L ; 6 2 0 3 P ; 6 2 0 4
Remote control PULT 6204 powered by one 27A 12V battery
Remote control PULT 6203 Roll
Remote control PULT 6203 P (100m)
(Remote control 12bit PULT 6203**)
Powered by one 12V type A23-5mA battery
DUCATI’s rolling coded remote controls: Pult 6203R; 6203P; 6204
The DUCATI radio rolling coded transmitters, featuring a unique “rolling code” (billions of continuously changing combinations)radio protocol ensure maximum protection against radio interference.
Frequency:433,92MHz
Each transmitter button is factory programmed with a unique code
Each button can be used to control a different DUCATI rolling coded gate, garage door opener or parking post.
By adding an external DUCATI rolling coded radio receiver (Rixi 6040 or 6043 with display) it is also possible to control other types of devices of any type and mark by a DUCATI rolling coded remote control
To operate your “DUCATI” opener with your DUCATI remote control you must memorize the remote control code on the electronic board of your opener.
WARNING: Operate adjustments and settings only with garage door or gate in closed postion.
A) To memorize the remote control code inside the electronic panel of the opener:
The door must be closed and idle.
- Press button P1 on the electronic board. The red LED switches on.
- Release button P1 and immediately press on the buttons of the remote control that you wish touse to operate the device. Hold the remote button pressed for about 4 sec. - the LED light on the electronic board will quickly blink to show the procedure has been completed.
- Press again the memorized remote control button, the opener will start an manoever
Warning: The memory of the controller can store up to 10-20 codes depending on the model (check the capacity of your memory card. If you need a larger number of remote controls is available an optional external receiver (RIXY6040 o RIXI 6043)
B) To erase the codes from the control board:
To deactivate any unwanted remote, erase its memory from the electronic board of your opener as following (all remote control codes memorized will be delated):
- The door must be closed and idle.
- Press button P1 for about 20 sec. until the red LED blinks
- Release P1.
- All remote control codes have been delated.- Reprogram each remote you wish to use following procedure on point A)
Titti i codici sono stati cancellati. Per reinserire nuovamenti i codici del telecomando seguire le operazioni del punto A da 1 a 4.
** IMPORTANT NOTE: Ducati 12 bit Radio remote controls model 6203, are 2 channels 12 bit coded remote controls compatible to 12 bit coded versions devices only. Each button can be used to control a different DUCATI rolling coded gate, garage door openerand. The coded trasmitted is a simple 12 bit binary fix code.
6203 12 bit coded remote controls are compatible only with 12 bit coded electronic boards (12 bit coded electronic board suffix is CTR and not CTH as per rolling coded electronic boards).
The 12 bit coded remote control model 6203 is very similar to the rolling coded ones, but has transparent push buttons ( sometimes also transparent case) while rolling coded radio 6203R is dark blue with dark blue buttons and rolling coded model Model 6203P (Enhanced Model 100m) is dark blue with red buttons
Each remotes has a standard 12 bit BINARY code.
STANDARD CODE MEMORIZED ON CHANNEL 1 = push button NAMED “OFF” = ON; OFF,ON;OFF;ON;OFF;ON;OFF,ON, OFF;OFF;ON
STANDARD CODE MEMORIZED ON CHANNEL 2 = push button NAMED “ON” = OFF; OFF,ON;OFF;ON;OFF;ON;OFF,ON, OFF;OFF;OFF
A personal code must be programmed to avoid not athorized command by other 6203 remotes.
To program a personal code IN YOUR 12 BIT REMOTE CONTROL follow these steps:
1. Simultaneously press the ON and OFF the remote control for about 10 seconds until the LED lights up steady.
From now on the remote control it is in the programming function; release thebuttons, the LED turns off.
2. Press for about 1-2 seconds the channel you wish to use to command your device ( ON button = channel 1 ; OFF button = channel 2)
,the LED lights on for about one second.
3. Press the buttons (OFF) (ON) making up your string coding to 12 pulses ( it is recommended to previously mark your personal code to be sure have it saved) after each pulse wait until the LED gswitches off.
4. On the thirteenth pulse, the remote control will flash to indicate that the programming has been accepted.
To store or delete the electronic card (note: only if series CTR) code, do the above procedure A) as for for the rolling coded remotes.
41
D U C A T I
F I X C O D E D U P L I C A T O R R E M O T E C O N T R O L G E M I N I 6 2 0 5
4
3
2
1
A) EREASE TEH MEMORY
(procedure needed also in case of new transmitters)
The LED will flash 3 times
A2- Continuing to hold pushed button 3; release button 4
A3- while holding down button 3, press 3 times consecutively button 4
The LED flashes to indicate that the delating procedure was successful.
A4- Release all push buttons
To confirm that the deletion procedure was successful, you can check that by pressing any button for one second LED does not light.
GEMINI 6205
With this 4-channel radio remote control you can copy and duplicate any fixed code transmitters working on 433 MHz frequency.
Each button can duplicate a different remote control of any brand.
B) DUPLICATE AN EXISTING FIX CODE REMOTE CONTROL
B1- place the remote control near the existing remote control copier, as shown in picture n°2
B2- Press and keep pushed the push button on the original fix code remote control that you wish to duplicate.
B3- Press and keep pushed the choosen button on GEMINI 6205, after two seconds the LED light quickly flashes 3 times to indicate it’s entered in learning mode. Hold down the buttons until the LED blinks slowly to indicate that the radio control has been duplicated
B4- Release all buttons. The procedure has been completed.
Caution: If the copying procedure does not conclude correctly repeat the procedure from step 1.
pic.1
pic.2
Existing remote control
(any brand / model can be duplicate if transmitts a FIX code on 433,92MHz)
New GEMINI DUPLICA-
TOR remote control
42
D U C A T I
R a d i o r o l l i n g c o d e d K E Y P A D T A S T Y 6 5 0 0 / S W 6 5 0 0
SW6500/TASTY 6500 outdoor use DUCATI RADIO ROLLING
CODED KEYPAD works on433,92MHz frequency
By digiting a 4 digit codes + ENTER the keypad will transmit a rolling coded radio signal to command your door opener.
Fix the keypad on wall or pillar. It’ss recommended to place where it can be protected from rain even if it’s suitable for outdoor use. It must be installed at a maximal distance of 10m from the electronic board of the opener. The keypad is supplied with a standard code =1111.
It is recommended to replace the standard code with a personal secret
4 digit code before to store the keypad it in the electronic board’s memory. it is possible to memorize max. 10 different personal code.
The Keypad are 1 channels only. Any of the memorized personal coded will all be used to tramnsitt on the same channel ( each single channel keypad can command 1 opener only)
Warning : it is extremely important to write down each personal code. because if it is forgotten the keypad could not be resetted and it will be unusefull.
Warning : in case of digiting a faulty code for 3 times the kaypad will turn into in stand-by for 10 minutes . Durring this stand-by time it wont accept any further digiting. Wait 10 minutes befor to try again to insert the correct code.
1) How to replace the standard code with a personalized 4 digit code ( first operation) digit the standard code 1111 + 3 + the 4 digit of the choosen personal code + ENTER. The keypad will make a BEEP to confirm that standard code has been replaced. ATTENTION: it is extremely important to write down thepersonal code. In case it is forgotten the keypad cannot not be resetted by the customer and it will be unusefull. If hthis occurs it must be shipped back to the manufacturer to be resetted. Costs will be at the charge of user.
A) To memorize the Keypad code in the electronic panel of the opener:
The door must be closed and idle.
- Press button P1 on the electronic board. The red LED switches on.
- Release button P1 and immediately on the keyswitch positioned by the electonic board digit the 4 personal code + ENTER ( hold enter for about 1,5sec. at least) until the keypad confirms with a “beeep”. Hold the - the red LED light on the electronic board will quickly blink to show the procedure has been completed.
Warning: The memory of the electronic board of your opener can store up to 10-20 codes depending on the model (check the capacity of your memory card). If you need a larger number of remote controls is available an optional external receiver (RIXY6040 o RIXI 6043)
To operate your gate you must digit on your KEYPAD your personal code + ENTER ( hold enter for about 1,5sec. at least)
2) How to replace a persoanl code with a new personal code: digit the personal code you wish to be replaced + 4 + the four digits of the new personal code + ENTER.
The keypad will make a BEEP to confirm that the personal code has been replaced.
3) HOW to add a new 4 digit code (without delating the previousely setted 4 digit codes): digit one of the previously setted 4 digit codes+ 3 + the new 4 digit code + ENTER The keypad will make a BEEP to confirm
4) How to delate a specic 4-digit code from the keypad digit the code you want to delate + 5 + ENTER, the LED on the keypad will start blinking, press again on ENTER ( within 1,5sec.) and hold pressed until the LED blinks, then release Enter The keypad will make a BEEP to confirm
5) How to delate all the codes setted in the keypad ( all codes will be delated) digit one of the previously setted 4 digit codes+ 6 + ENTER. The LED on the keypad will start blinking, press again on ENTER ( within 1,5sec.) and hold pressed until the LED blinks, then release Enter .The keypad will make a BEEP to confirm the procedure has been compleeted.
WARNING: the Keypad will go back to the standard code =1111 but with this standard code it will not be possible to command anymore the opener. It will be necessary to re-set a new personalized code following instructions of point 1 above.
B) To erase your KEYPAD from the control board of your opener:
To deactivate any unwanted remote, erase its memory from the electronic board of your opener as following (all remote control codes memorized will be delated):
- The door must be closed and idle.
- Press button P1 for about 20 sec. until the red LED blinks
- Release P1.
- All remote control codes have been delated.- Reprogram each remote you wish to use following procedure on point A)
43
D U C A T I
K E Y S W I T C H K E Y 5 0 0 0 / K E Y 5 0 0 5
Wired Key Switches: KEY 5000 / KEY 5005 / KEY 5005 INOX
Connect connectors 1 & 2 to the START normally open contact of any DUCATI electronic board to command a full cycle maneuver ( both wings will operate a full cycle, or in case of single wing gate use, the single gate will operate a full cycle)
Connect connectors 1 & 2 to the PEDESTRIAN START normally open contact of a DUCATI electronic board to command a partial pedestrian maneuver ( only 1 wing will partially open to permit pedestrian access only)
In case you want to connect more than one key swithc or any other NO Switch or Braker make a parallel connection. For extra safety it is advisable to wall up the connection cable.
KEY 5005 KEY 5005 INOX
1
2
KEY 5000
58mm
33mm
1 2
54 mm
25 mm
44
D U C A T I
4 c h a n n e l s r a d i o r o l l i n g c o d e d e x t e r n a l r e c e i v e r R I X Y 6 0 4 0 R O L
The outdoor use 4-channel DUCATI rolling coded adio receiver allows you to control up to 4 automatic devices of any type by means of any ducati rolling coded remote controls.
N° of channels: 4
Each channel storage capacity: max. 25 codes
Radio frequency 433,92 MHz
Contact rating relay: 1A /30V
Working temperature: -10°C / + 60°C
Irradiation of antenna: in compliance with EU
Norms
Consumption: 8mA in stand-by
The radioreceiver can be powered by the 12V power outputs of the electronic board of a Ducati device (you can use the photocells positive + and negstive- outputs to power the radio receiver.
The board has 4 channels: CH1; CH2; CH3; CH4. Each channel t can be used to control a different function of the same gte opener or different devices.
Connect the output terminals of the chanel on the radio receiver to the imput terminals of the electronic board of the device you wish to control.
Example: if you want to use Channel 1 of the radio receiver to command the full cycle opening of your gate opener: connect terminals of CH1 to the
START contact of the main board of your gate opener.
If you wish to use Channel 2 to command the pedestrian opening of your gate opener, connect terminals CH2 to the “ PESDESTRIAN START” terminals of your gate opener. If you wish to control your garage door opener by Channel 3 connect terminald CH3 to the start terminals of your garage door opener. You can also connect the channels to a non DUCATI device. This way you will be able to operate any device with the same Ducati rolling code remote control. This will not prevent the use of the originals remote controls of other devices. Ducati radio receiver will work together to theoriginal radio receiver of the device. You will have to memorize the push buttons of your remote controls in the corresponding channel of your external receiver.
SWITCHES
Used to determine if the channel is used with monostable contact (start impulse) or bistable (switch that maintains closed or open the circuit)ogni switch
Each switch is used for the correspondent channel example: switch n° 1 is used for channel CH1;
To sycronize/ store the remote controls buttons in the radio receiver:
On the radio receiver push the button corresponding to the channel you wish to use the remotes with
CH1 = channel 1 use P1 to store the radio remote control push button
CH2 = channel 2 use P2 to store the radio remote control push button
CH3 = channel 3 use P3 to store the radio remote control push button
CH4 = channel 4 use P4 to store the radio remote control push button
The red LED light corresponding to the choosen channel switches on. Push the button of your remote control that you wish to use.The red LED light blinks to confirm that the operation was completed successfully.
To delate the stored remote controls:
On the radio receiver, push and hold pushed the button corresponding to the selected channel. After about 30 sec the LED blinks to conirm all remote control codes on that channel have been delated.
P1 P2 P3 P4 switch
CH1 CH2 CH3 CH4
NO contact without polarization
NO contact without polarization
NO contact without polarization
NO contact without polarization
Main Power
12V/24V ac/dc
45
D U C A T I
3 c h a n n e l s r a d i o r o l l i n g c o d e d e x t e r n a l r e c e i v e r R I X Y 6 0 4 3 R O L
CAUTION:
SLIDE SWITCH function on / off display.
ON = Display on,
OFF (1) = display off
CH3 channel temporization adjustment 0-6 min. max.
contact NO without
CHANNEL 1
TIME
P1
SWITCH ON =
Display on,
P2 switch
P3
DISPLAY A shows the channel
1 = CH1
2 = CH2
3= CH3
P4
P6
P5
The 3-channel radio receiver allows you to control up to 3 automatic devices with
DUCATI ROLLING CODE remote controls.
Each stored radio code is identified in a specific position number displayed on the display.
Channel CH3 allows also to set a timerized command (0- 6 minutes)
Radio transmission protocol: Ducati rolling code
MAx. storage capacity: 100 radio codes. monostable / timerized function 12/24V ac/dc
Frequency: 433,92 MHz
Relay contact capacity: 1A /30V
Working temperature: -10°C / + 60°C
Irradiation of antenna: in compliance with CE norma
Tensione di alimentazione 12/24 V ac/dc
Stand-by consumption: 38 mA
DISPLAY B shows the position number of the stored remote control (Max 100 total positions 00 to 99)
POWER SUPPLY: The radio receiver can be powered from the 12V or 24V power output of ithe device’s electronic board There are no polarity to be respected.
Before activation: Place the SWITCH ON to turn on the display.
The receiver performs a testing procedure. With completely empty memory the display will show: CC on the display. Wait until the diplay gets off.
Caution: to activate the display place the switch on ON position. Note: the displays will light up by pressing one of the programming buttons or upon receipt of a radio signal previously stored.
With switch on 1 = OFF the displays are always off
1. How to memorize a remote control code ( button) a. Push P1, the display switches on.
b. by pressing push P6 you can choos on witch channel you will store the remote control button c. PPush the remote contro’sbutton you wish to emorize. If the procedure is compleeted correctly the A display will blink and shows the channel on witch the rmemote control button has been stored. The B display will shoew the position number where the rmote control button has been stored . Example: 2 03
(channel 2 ,position 3)
Simultaneously the red LED lights on. Then the display turns off.
2. How to delate a specific previously memorized radio remote code (button) a. Press P2. The A display will show “P”, the B display will show: - -. release P2 b. displays will now show: P 00 c. Identify the position number you want to delate by pressing push button P6( increase) or P5 ( decrease) d. Push again P2 and hold it pushed until the red lLED light switches on. The position number witch is beeing delated is blinking on the display. once the code is delated the display switches off. Release P2.
sock antenna antenna cable
Power supply 12V
/ 24V ac / dc
3. How to delate all stored codes a. Push and hold pushed P3 3 until the display shows: CC. b. release P3. The process continues until the total erasure of the memory and can not be interrupted.
4. How to check how many positions are still availables to memorize new codes: a. Press P4. the display will show the number of free positions b. release P4
46
D U C A T I
P h o t o c e l l s S W 7 0 1 2 / L A S E R 7 0 1 2 & S W 7 1 2 0 / L A S E R 7 1 2 0
Photocells are an actve security optional device active during the closing phase of the gate .It prevents that the gate gets in contact with an obstacle that is trapassing the infrared light transmitted from the transmitter photocell to the receiver photocell.
It is advisable to mount the photocells at a height from the ground between 40 and 100 cm. Photocells can be installed directly on the pillar (without embedding) or on special support columns.
The obstacle is detected only if it is located between the infrared light beam between the two photocells. The device is composed of a transmitter TX and receiver RX. The transmitter TX emits a modulated infrared light that is detected by the receiver RX, when this beam of light (invisible) is interrupted by the presence of an obstacle, a signal is sent to the electronic board and the doors reverse the direction of travel (this happens only in the closing phase.) Do not install the photocells at a distance higher than 10m.
Model SW7012 or LASER 7012: pair of niversal photocells u12 / 24V ac / dc
Models SW7120 or LASER 7120: pair of low consumption photocells. Special model recommanded expecially if to be used on of solar powered openers (CTH44 & CTH48 control board)12 / 24V ac / dc
Unscrew the cover of the photocell to fix them to the pillar / column. It is mandatory to perfectly align the photocells.
Attention: photocells model 7012 & 7120 are aesthetically identical.
They shall be identified and distinguished by the label affixed to the back of the device. Moreover, the model is also indicated on the printed circuit of the RX photocell
Caution: with CTH44 and CTH48 electronic boards powered by the solar panel is indispensabie use of photocells model 7120 in order to contain the consumption of the system. It is advisable, in such cases, to install a single pair of photocells.
TX (same in photocell model 7012 & 7120)
1 (+)
2 (-)
RX (model 7012)
1(+)
2 (-)
3 (COM) common
4 FTC
(NC contact)
RX (model 7120)
1(+)
2 (-)
3 FTC
(contact NC) do not use the 4° connector !
Connectors on photocells 7012 & 7120
1 = + Positive power supply 12 / 24V AC / DC (for both models)
2 = - negative power supply 12 / 24V AC / DC (for both models) connect to the related terminal of the DUCATI’s opener electronic board
Photocel RX (receiver) models 7012 (universal photocells)
3 = common. connect to COM ( common) terminal of the electronic board
4 = FTC normally closed photocell contact. connect to the related terminal FTC of the DUCATI’s opener electronic board
Photocel RX (receiver) models 7120
3 = Connect to the FTC normally closed (NC) terminal on the DUCATI’s opener electronic board
WARNING: Do not use the 4th down terminal on the photocell RX 7120
Warning: by connecting the photocells, the bridge that keeps closed the photocell contact must be eliminated.
47
D U C A T I
P h o t o c e l l s S W 7 0 1 2 / L A S E R 7 0 1 2 & S W 7 1 2 0 / L A S E R 7 1 2 0
How to connect more pairs of universal photocells model 7012
+
-
+
-
COM
FTC (contact N.C.)
How to connect more pairs of special low consumption photocells model 7120
+
-
+
COM
-
+
COM
+
-
+
-
COM
FTC (contact N.C.)
+
-
COM
+ -
FTC
D U C A T I u n i v e r s a l p h o t o c e l l s m o d e l L A S E R 1 0 0
RX
FTC
+ -
TX
Model LASER 100: pair of photocells universal 12 / 24V ac / dc
Wiring:
1 = - negative power supply 12 / 24V AC / DC
48
3 = NO contact ( not to be used on DUCATi’s opener’s electronic boards)
4 = common. connect to COM ( common) terminal of the electronic board
5 = NC contact Connect to the FTC normally closed (NC) terminal on the
DUCATI’s opener electronic board
1 2
+
1 2 3 4 5
+ COM FTC (contact NC)
D U C A T I f l a s h i n g l i g h t & e x t e r n a l a n t e n n a H C , F L A S H e S T I L O
The flashing must be installed on the pillar / wall and be clearly visible from inside and outside the property.
in modo che sia perfettamente visibile dall’interno e dall’esterno della proprietà.
The blinking is slow in opening and faster during closing.
The installation of the flashing light is mandatory to ensure security on public transit area.
The flashing lights model:FLASH 7712; 7512, HC7500 / 12 use a 12V max 10W bulb
The flashing lights model: FLASH 7724; 7524 HC7500 / 24 use a light bulb max 10W 24V
External antennas can be added in case you need to deport the outside radio reception. Not recommended for use unless absolutely necessary given that they increase the risk of a brake circuit on the circuit board due to electrostatic discharges during thunderstorms.
flashing light SW/ FLASH & external antenna STILO
flashing blinker SW/ FLASH with standrd bulb
49
D U C A T I
P h o t o v o l t a i c S o l a r P a n e l
solar panel SOLAR 1010 (10W) / soalr panel 1020 (20W)
Place the solar panel to a recommended maximum distance of 10 m from the control box. Fasten the panel to the wall with the supplied bracket. The solar panel should face SOUTH. Check that no obstacle creates shadow on the panel and that it is in full light. Connect the panel to the circuit board being careful to respect the polarity of the wiring.
Warning: in case of intensive use or to ensure greater autonomy in low light conditions it may be advised to use solar panel
SOLAR1020 (20W) to be used by combining a minimum 12V 12A battery. The 12V battery 12A must be housed in an external box
SOLAR 101010W solar panel mountig bracket
Solar 1020 20W solar panel mounting bracket control board consumption table
MOTOR
1 wing gate electonic board
CTH44 or CTH48 2 wings gate stand-by consumption/
(A/h) daily standby consumption (A)
0,007 0,16
Full cycle ( open
+ close) consumption (A) hypothesis: daily full cycles total daily consumption
(A)
0,012
0,024
60
50
0,88
1,24
10W solar panel averagerecharge capacity ( A/h) hypotheses: daylight hours
daily in the worst conditions total daily recharge capacity
(A) energy surplus accumulated and not used during the day (A)
0,3 5 1,5
+ 0,62
+ 0,26
The table gives an estimation of autonomy in the worst light conditions (we calculated only 5 hours of daily light with a low brightness level).
This condition may correspond to the situation: winter with overcast / partly covered or veiled.
The table shows the maximum number of maneuvers, maintaining the same level of charge of the battery.
With summer weather and excellent exposure to light for more hours per day, the levels of autonomy increase exponentially.
With use of photocells and especially in the case of double pair of photocells SW7120 we recommend the use of a 20W panels combined with a 12A battery to ensure an even better energy autonomy.
NOTE: the solar panel 1020 combined 12V 12A battery has a charging capacity of about 1A / hour ,exponentially increasing the autonomy compared to a 10W panel 7A battery.
Caution: the use of a solar panel 20W combined to a 12V 7A battery is inadvisable because it would not exploit all the charge given by the panel.
50
D U C A T I
A C C E S S O R I E S
Accssories: remote controls, radio receivers and other wired controls devices
MODEL PICTURE
PULT 6203 12BIT 12 bit, fix coded, 2 channels remote control. 433,97 MHz
PULT 6203 R Ducati radio rolling coded , 2 channels remote control 433,97 MHz
PULT 6203 P
DESCRIPTION
Ducati radio rolling coded , 2 channels remote control 433,97 MHz. working distance : 100m
PULT 6204 Ducati radio rolling coded , 4 channels remote control 433,97 MHz
GEMINI 6205
RIXY 6040
RIXY 6043
STILO 6023
STILO 6025
TASTY 6700
TASTY 6704
SW 6500
SW 6504
KEY 5000
KEY 5001
KEY 5005
KEY 5005 INOX
Duplicator of any fix code remote contro transmitting at 433 MHz
4 channels Radio receiver. Ducati radio rolling coded. 433,97 MHz. storage capacity: max.100 codes ( 25 each channel) stable/ bistable
3 channels Radio receiver with display. Ducati radio rolling coded. 433,97 MHz. storage capacity: max.100 codes.1 channel with temporization 0-6 minutes. stable/bistable
Universal Antenna 433,92MHz. fixing bracket & 5m cable included. +0,5Db
Universal Antenna 433,92MHz. 5m cable included. +0,5Db to be directly fixed on FLASH blinkers
1 channel radio keypad .Ducati radio rolling coded , 433,97 MHz for outdoor use stainless stell case
4 channels radio keypad .Ducati radio rolling coded , 433,97 MHz for outdoor use stainless stell case
1 channel radio keypad .Ducati radio rolling coded , 433,97 MHz for outdoor use
4 channels radio keypad .Ducati radio rolling coded , 433,97 MHz for outdoor use key switch NO with 1 pair of keys key switch NO with 1 pair of keys key switch NO with 1 pair of keys key switch NO with 1 pair of keys stainless steel finishing
51
D U C A T I
A C C E S S O R I E S
Accessories: Flashing lights, antenna , solar modules & batteries
MODEL PICTURE
FLASH 7712 12V blinker with white dome and yellow bulb
FLASH 7724
FLASH 7512
24V blinker with white dome and yellow bulb
12V blinker with yellow dome and white bulb
FLASH 7524
HC 7500/12
12V blinker with yellow dome and white bulb vintage design 12V blinker with yellow dome and white bulb
HC 7500/24
.../ LED
KB 9000 vintage design 24V blinker with yellow dome and white bulb
LED ligh tmodule for FLASH flashing light xenon lamp blinker
DESCRIPTION
STILO 6023
SOLAR SET 1010
SOLAR SET 1010
SOLAR 1010
SOLAR 1020
Universal Antenna 433,92MHz. 5m cable included. +0,5Db to be directly fixed on FLASH blinkers
SOLAR SET contents:: 1 x SOLAR1010 10W solar panel + 1x BAT1012 12V 7A battery+ 1 MPBAT battery charger with plug
SOLAR SET contents:: 1 x SOLAR1020 20W solar panel + 1x BAT1212 12V12A battery+ 1 MPBAT battery charger with plug
10W 12V solar panel with fixing bracket
20W 12V solar panel with fixing bracket
SOLAR 2020
BAT1212
BAT 1012
BAT 1012
SLIM
C/M/BAT
MPBAT
20W 24V solar panel with fixing bracket
12V 12Ah rechargable battery. dimensions: 9 cm h x 15 cm x 10cm
12V 7Ah rechargable battery. dimensions: 9 cm h x 15 cm x 6,5cm
12V 5Ah rechargable battery. dimensions: extra thin measures 9 cm h x 15 cm x 5cm battery charger module for electronic board CTR42
12V 0,5A battery charger with cable and UE plug class A. polarized +/- terminals 6,3
52
D U C A T I
A C C E S S O R I E S
ACCESSORI : SAFETY DEVICES
MODEL PICTURE
LASER 7120
LASER 7012
LASER 100
SW 7120
SW 7012
DESCRIPTION
Pair of low consumption photocells with stainless steel case. compatible with scontrol board CTH44 & CTH48. 12/24V a.c./d.c./NC
Pair of univerala photocells. 12/24V a.c./d.c./NC
Pair of universal photocells. 12/24V a.c./d.c./NC
Pair of low consumption photocells. compatible with scontrol board CTH44 & CTH48. 12/24V a.c./d.c./NC
Pair of univerala photocells. 12/24V a.c./d.c./NC
KOL 600 pair of aluminium coloumns h60cm with fixing bracket (photocells are not included
E-LOCK 1012
Booster 1012
12/24V ac electolock
Booster for electrolock E-LOCK1012
53
D U C A T I
S P A R E P A R T S
telescopic actuators
HC312
HC412
54
actuator SW400 actuator HC418
D U C A T I
S P A R E P A R T S
Sper parts compatibles to all actuators
MODEL PICTURE
R70 pair of carbon brushes. compatible to all SW & HC actuators
DESCRIPTION
R15
R14
GIU0114
0138
HC actuator’s spare parts
R39
R76
R4
R40
R9
R9/418 trilobic unlocking key. compatible to all SW & HC actuators release pawl. compatible to all SW & HC actuators
1,25 Z27 sinterized gear compatible to all SW & HC actuators
1 m motor cable H05RNF for outdoor use with 2 faston . compatible to all SW & HC actuators rotor for actuators HC418; HC312;HC412 gearmotor for actuators HC418; HC312;HC412
PA6 gearmotor housing (2 pcs:bottom and upper housing) for actuators HC418; HC312;HC412 carbon brushes holder ( carbon brushes are not included) for actuators HC418; HC312;HC412 painted aluminium profile for actuators HC312 ( 2016 version is provided in black colour only whil previous versions where grey painted) painted aluminium profile for actuators HC418; HC412 ( 2016 version is provided in black colour only whil previous versions where grey painted)
55
56
D U C A T I
S P A R E P A R T S
MODEL
R1
R1/400
R2
R2/400
PICTURE DESCRIPTION stainless steel tube with nut screw, and front fixing junction. for HC312 stainless steel tube with nut screw, and front fixing junction. for HC412 long screw with roll bearing & gear for actuator HC312 long screw with roll bearing & gear for actuator HC412- HC418
SW010
R37 nut screw with slide & front fixing pin. for HC418 front cover for HC312 e HC412
R37
R11
R8
R8/818 front cover for HC418 pins and ciquit clips for actuators HC418; HC312;HC412 ( 2 fixing pins + 4 cirquit clips)
Fixing brackets compatible with actuator HC312;HC412. The sets contents 4 plates ( for 2 actuators)
Fixing brackets compatible with actuator HC418; The sets contents 4 plates ( for 2 actuators)
R39SW
R76SW
SW125
SW114
SW124
Sw110
R2/400
R1/400
D U C A T I
S P A R E P A R T S
SW ACTUATOR’S SPARE PARTS
MODEL PICTURE
SW101 ABS gearmotor cover for SW400 / SW400T
SW100
GIU110
DESCRIPTION
PA6 gearmotor housing for SW400 / SW400T carbon brushes holder ( carbon brushes are not included) for SW400 / SW400T rotor for SW400 / SW400T
12V gear for SW400 / SW400T painted aluminium profile for SW400 & SW400T front cover for SW400 front cover for SW400T nut screw with slide & front fixing pin. for Sw400 long screw with roll bearing & gear stainless steel tube with nut screw, and front fixing junction. for SW400T
57
D U C A T I
S P A R E P A R T S
PICTURE MODEL
Sw105
DESCRIPTION pins and ciquit clips for actuators Sw400 / SW400T ( 2 fixing pins + 4 cirquit clips)
PLBOX 812
58
PLBOX 818
TRASFO 105
TRASFO
105/110
CTH41
CTH42
CTH44
CTH48
CTH48 /24
CMBAT
R8 fixing brackets compatible with actuator SW400T. The sets contents 4 plates ( for 2 actuators)
R8/818 fixing brackets compatible with actuator SW400. The sets contents 4 plates ( for 2 actuators)
CONTROL BOXES & ELECTRONIC BOARDS SPARE PARTS
MODEL
PLBOX
PICTURE DESCRIPTION control box inner protection compatible with “large control box & electronic boards CTH42;CTH44;CTH48 control box ( cover + bottom) “Large” control box ( cover + bottom) “small” trasformatore 230V 105W 0-12-24V outputs toroidal transformer 110V 105W 0-12-24V outputs
ELECTRONIC BOARD 12V
ELECTRONIC BOARD 12V
ELECTRONIC BOARD 12V
ELECTRONIC BOARD 12V
ELECTRONIC BOARD 24V
ELECTRONIC BOARD-BATTERY CHARGER MODULE compatible with CTH42
D U C A T I
S A F E T Y. C E R T I F I C A T I O N S & E U N O R M S
DUCATI GATE OPERATORS: A GUARANTEE OF SAFETY & RELIABILITY IN FULL COMPLIANCE WITH THE EUROPEAN REGULATIONS
As Safety is of primary importance,DUCATI’s is proud to ensure that his products and accessories comply with the latest European laws and machinery directives.
SAFETY AND FINAL INSPECTION
The manufacturer guarantees, as tested and cerificate by NEMKO and INTERTEK regulators that their actuators, used with the original control units rlative, when properly installed according to this manual are in compliance with the European standard EN 12445; EN 12453; EN 12635 and EN 13241-1
Note that the final machine is composed by the gate operator with the gate itself ( structure). The installer by using a specific dynamometer, has to test and certify to the final user that the machine composed by the gate and the gate opener in their entirety, comply to the EU normsas as required by the specific legislation. he European Union has passed a series of laws which clearly regulate the automation industry. The full range of DUCATI’s products has been not only tested but also certified by international bodies to comply EN12453
EN12445 norms and ready to be certified on site by the installers.
Any new or existing installation requires a declaration of conformity issued by the final installer. The installer must test the final machine and attest the compliance to the latest European standards concerning impact forces in case of obstacle detection. Tests must be performed with a dinamoteter in precisely specified positions
DUCATI devices are ready to achieve total safety even when installing in a variety of contexts. Thanks to these standards many businesses in automation industry choose DUCATI technology to ensure their installations
We certify that the products listed in this manual are in compliance with EU norms:
EMC - COMPATIBILITA’ ELETTORMAGNETICA
EN55014-1-2006+A1:2009
EN55014-2-1997+A1+A2:2008
EN61000-3-2:2006+A1+A2:2009
EN61000-3-3:2008
LVD - DIRETTIVA BASSA TENSIONE
EN60335 1-2001+A13 2008 + A14 2010
EN60335-2-103:2003 +A11 2009
EN62233-2008
NORMATIVA SICUREZZA DA IMPATTO
EN 13241-1:2003 +A1
EN12453:2000
EN12455:2000
R&TTE - RADIO & TELECOMUNICAZIONI
EN301489-3V.1.4.1
EN 300 220-2V.2.1.2
FCC- USA COMMISSIONE TELECOMUNICAZIONI
FCC ID: OLS137925764 Washington laboratories tested * remote mod.6203
RoHS - RESTRICTION OF HAZARDOUS SUBSTANCES
59
D U C A T I
W a r r a n t y , a s s i s t a n c e & c u s t o m e r s u p p o r t
MANUFACTURER’S LIMITED WARRANTY
1 The guarantee shall be liable only for defects which are due to manufacturing or material defects.
2 The warranty is valid for two years from date of purchase.
3 Manufacturing error should occur within this limited warranty period, the customer must report this immediately and before disassembling the product to the customer service of the dealer. The product should be returned to the manufacturer where it is tested. Before sending the product, the warranty request must be submitted to the manufacturer.
Transportation costs are charged to the customer .
The customer should enclose a brief description of the problem and the cash receipt as proof of warranty periode.
4 The manufacturer’s obligation is limited to the repair or replacement of the product. A refund of the purchase price is not possible without specific agreement with manufacturer.
Defective parts will be repaired or replaced with new parts from the manufacturer
5 This limited warranty does not cover: Transport costs, maintenance costs of the product or installation , inspection or control of parts of the product for any reason whatsoever, within and outside the warranty period, shall be borne by the customer and never at the expense of the manufacturer.
6 This warranty does not apply interventions or modifications by unauthorized third parties or the end user, as well as improper or inadequate installation, it must be taken according to the installation instructions and use only as directed and use as described by the manufacturer .
Intentional or accidental damage , as described above, are not entitled to warranty.
7 There is no liability for : a) installation , periodic inspection , maintenance, the costs for the installation of the repaired or replaced parts .
b ) The warranty does not cover wearing parts, such as Fuses, batteries , brushes, bulbs , etc.
c ) transportation costs, maintenance or installation, with respect to this product , for any reason whatsoever, including shipping back to the company , in or out of warranty are to be borne by the customer or selling dealer and never at the expense of the manufacturer.
d) misuse, improper installation , damage or malfunctions that are not due to product defects , damages that are due to external environmental influences of any kind , improper maintenance or repair , improper alteration to the product, with structural problems of pillars, gates , doors, etc.
e ) Damage caused by fire, humidity , water, natural phenomena , thunderstorms , lightning
Radio interference or interference from other electrical devices ; shorts due to a wrong power connection or power fluctuations on the network as well as all other cases beyond the control of the manufacturer.
8 The warranty is subject to compliance with the technical characteristics and correct , proper installation according to instructions .
CUSTOMER CARE & ASSISTANCE
WORLDWIDE DELIVERY within 2/3 days
TAILORED CUSTOMER SERVICE & ASSISTANCE 7/24
We favor the human relationship and direct contact with the customer to meet every need.
we are a CUSTOMER-FRIENDLY company. Don’t hesitate to contact us we speak English, français, Italiano, Deutsch
for any inquiry write to: [email protected] phone call: +39-335-1022019 / +39/0524-527967
60
D U C A T I
F A Q : g u i d e t o s o l v i n g m a j o r p r o b l e m s
PROBLEMS RELATED TO THE RADIO RECEPTION
SYMPTOM POSSIBLE CAUSE SOLUTION See pag. one of the radio remote controls is not working, while the other remote controls work properly battery of the remote control is out of power/ has not enough power elctronic board storage capacity is full any of the radio remote controls works defective or broken remote control the radio controls were not stored in the automation control board the radio control model used is not compatible with the electronic board replace the battery of the radio remote controls erase the memory on your electronic board and re-store the remote control button you want to use, taking care not to exceed the limit of storable codes. if you must use a greater number of remotes, add an external radio receiver model 6040rol or 6043 with dispaly if under warranty send the remote control support for check and replacement. if out of warranty purchase a new remote control
precautionary reset the memory of the electronic board of your opener, and then store one by one the radio control channels that you want to use.
Be sure to use the original DUCATI remote controls and be sure to use a model of remote control compatible with your electronic board.
The generation “CTR” boards use radio remote controls with fixed code 12-bit , while the “CTH” generation boards use radio rolling coded remote control.
30
30
30
30 the radio remote controls only work at close range battery of the remote control is out of power/has not enough power radio interference on board radio hybrid receiver damage
The gate opens by itself on board radio hybrid receiver damage radio interference from other devices
Contact the DUCATI official assistance centre. send the board to he assistance for repair in or out of warranty. If out of warranty radio receiver problem you can n also opt to buy an external radio receiver 6040rol or 6043 in order to avoid sending the damaged board to the service center.
To check that the problem is on the hybrid radio receiver. Try to operate your gate opener commanded by wired control (use a keypad or bridge the “START terminals”) to check the correct peration not radio control) replace the battery of the radio remote controls identify the cause of the interference / noise / barrier to radio reception and eliminate it
Contact the DUCATI official assistance centre. send the board to he assistance for repair in or out of warranty. If out of warranty radio receiver problem you can n also opt to buy an external radio receiver 6040rol or 6043 in order to avoid sending the damaged board to the service center
Problems verifiable with radio 12-bit encoding openers only, which are subject to interference from other radio devices. it is suggested to change the system with a radio rolling code version that with over 3 billion continuously changing code guarantee absolute protection.
34-35
61
OTHER TYPE OF PROBLEMS the gate opens but does not close and photocells are not installed photocells bridge do not make contact or has been removed error in connecting/wiring the photocells the gate opens but does not close and photocells are installed photocells are not aligned both doors open, but only one closes; una sola anta apre completamente ma la seconda non effettua alcun movimento one door completely open but the second does not perform any movement
the gate opens but stops the movement before the mechanical stop the leaf is moving too fast and slams on the setback photocells are dirty inside or outside relay stucked relay stucked you commanded the pedestrian opening cycle ( only one wing
M1 opens partially)
Wrong motor power/ obstacle sensitivness Adjustment
Not ideal actuator’s pfixing position on the pillar ( measures A &
B) are not the ideal ones)
Qualsiasi altro problema o malfunzionamento
62
SYMPTOM POSSIBLE CAUSE
To be analyzed with Ducati tecnicians first
SOLUTION re-place the photocell’s bridge that keeps closed the photocell contact on your electronic board. and check the contact face properly.
Check that you are using compatible photocells to your electronic board model ( note low consumption photocell model 7120 are only compatible with electronic board CTH44 & CTH48.
Check the photocells wiring: it could be incorrect . Check the wires are not interrupted.
Check that the fococells are correctly aligned
Open the photocells and check that there is no dirt or insects inside them. Clean the photocells, but mantain them aligned.
contact Ducati’s after sale service for under warranty or out of warranty repair contact Ducati’s after sale service for under warranty or out of warranty repair use another remote control button to control the full cycle opening increase the power by turning the potentiometer clockwise to increase the power and reduce the obstacle detection sensitiveness change the position of the fixing brackets by choosing a location which results in an increased use of the piston stroke.
With CTH48 card template regulate the beginning of the slowdown to a smooth stop of the movement on the mechanical stop. For large gate wings you couls evaluate to add an electrolock.
send an e-mail to info@ducatihome and describing your problem. It is important to indicate your gate opener model or at least your motor + electronic board model and date of purchase.
See pag.
36-37
6-8
visit
www.ducatihome.it
register your ACCOUNT today: you’ll get:
SPECIAL OFFERS
DISCOUNTS on extra accessories,
TAILORED CUSTOMER SERVICE 7/24h
NEWSLETTERS and much more!
d u c a t i h o m e . i t
Ducati Home Automation
Automazione cancelli via Cassani
43036 Fidenza (PR) ITALY t +39-0524-527967 f +39-0524-591085 mob.+39-335-1022019 [email protected]
Preuzimanje
Reklama