MCZ DUO HYDRO-AIR, SWING HYDRO Installation guide

Add to my manuals
80 Pages

advertisement

MCZ DUO HYDRO-AIR, SWING HYDRO Installation guide | Manualzz

INSTALLATION GUIDE

PELLET STOVE

DUO HYDRO-AIR

Instructions in English

EN

TABLE OF CONTENTS

TABLE OF CONTENTS .................................................................................................. II

INTRODUCTION ..........................................................................................................1

1-WARNINGS AND WARRANTY CONDITIONS .................................................................2

2-FUEL .......................................................................................................................7

3-INSTALLATION .........................................................................................................8

4-FLUE .......................................................................................................................9

5-DRAWINGS AND TECHNICAL FEATURES ....................................................................16

6-INSTALLATION AND ASSEMBLY ...............................................................................18

7 - HYDRAULIC CONNECTION ......................................................................................29

8-ELECTRICAL CONNECTION.......................................................................................32

8-PRECAUTIONS BEFORE START-UP ...........................................................................33

9 - CONTROL PANEL ...................................................................................................34

10 - FIRST START-UP .................................................................................................35

11 - MENU STRUCTURE ..............................................................................................38

12 - INFORMATION MENU ..........................................................................................42

13 - SETTINGS MENU .................................................................................................45

14 - TECHNICAL MENU ...............................................................................................59

15 - SAFETY DEVICES AND ALARMS .............................................................................60

16 - CLEANING AND MAINTENANCE ............................................................................65

17-FAULTS/CAUSES/SOLUTIONS .................................................................................71

18-CIRCUIT BOARD ...................................................................................................74

II

INTRODUCTION

Dear Customer, our products are designed and manufactured in compliance with European reference Standards for construction products (EN13240 wood-burning stoves, EN14785 pellet-burning appliances, EN13229 fireplaces/wood-burning inserts, EN 12815 wood-burning cookers), with high quality materials and extensive experience in the transformation processes. The products also meet the essential requirements of Directive 2006/95/EC (Low Voltage) and Directive 2004/108/EC (Electromagnetic Compatibility).

To get the best performance, we suggest you read the instructions in this manual carefully.

This installation and use manual forms an integral part of the product ensure that the manual is always supplied with the appliance, even if it changes owner. If the manual is lost, you can request another copy from the local technical service or download it directly from the company website.

All local regulations, including those regarding national and European regulations, must be observed when the appliance is installed.

In Italy, for the installation of systems with biomass below 35KW, refer to ministerial decree D.M. 37/08, and the qualified installation technician with the appropriate requisites must issue a certificate of compliance for the system installed. (By system one means

Stove+Chimney+Air inlet).

REVISIONS TO THE PUBLICATION

The content of this manual is strictly technical and the property of MCZ Group Spa.

No part of this manual may be translated into other languages and/or adapted and/or reproduced, even in part, in other mechanical or electronic forms, photocopies, recordings or other, without the prior written authorisation from MCZ Group Spa.

The company reserves the right to make changes to the product at any time without prior notice. The proprietary company reserves its rights according to the law.

CARE OF THE MANUAL AND HOW TO CONSULT IT

• Take care of this manual and keep it in an easily accessible place.

• Should the manual be misplaced or ruined, request a copy from your retailer or directly from the authorised Technical Assistance

Department. It can be downloaded from the company website.

• The " text in bold " must be read with particular care.

• “The " text in italics ” draws attention to other sections in this manual or clarifications.

• “NOTE” provides the reader with additional information.

SYMBOLS USED IN THE MANUAL

CAUTION: read the relative message carefully as failure to observe the information provided could result in serious damage to the product and put the persons who use it at risk .

INFORMATION: failure to comply with these provisions will compromise the use of the product.

OPERATING SEQUENCES: sequence of buttons to be pressed to access the menus or change settings.

MANUAL carefully read this manual or the relative instructions.

Technical Dept. - All rights reserved - Reproduction is prohibited 1

1-WARNINGS AND WARRANTY CONDITIONS

SAFETY PRECAUTIONS

• Installation, electrical connection, function test and maintenance must only be carried out by authorised and qualified personnel.

• Install the product in accordance with all local and national legislation and regulations in force in the region or state.

• Only use the fuel recommended by the manufacturer. The product must not be used as an incinerator. It is strictly forbidden to use liquid fuel.

• Do not put any fuel other than wood pellets in the hopper.

• The instructions provided in this manual must always be complied with to ensure the product and any electronic appliances connected to it are used correctly and accidents are prevented.

• The user, or whoever is operating the product, must read and fully understand the contents of this installation guide before performing any operation. Errors or incorrect settings can cause hazardous conditions and/or poor operation.

• Do not climb on or lean on the product.

• Do not put linen on the product to dry. Any drying racks or the like must be kept at a safe distance from the product.

Fire hazard.

•  All liability for improper use of the product is entirely borne by the user and relieves the Manufacturer from any civil and criminal liability.

• Any type of tampering or unauthorised replacement with non-original spare parts could be hazardous for the operator's safety and relieves the company from any civil and criminal liability.

• Many of the surfaces of the product get very hot (door, handle, glass, smoke outlet pipes, etc.). Avoid coming into contact with these parts, without adequate protective clothing or suitable implements, such as gloves with thermal protection or

"cold handle" operating systems.

• It is forbidden to operate the product with the door open or the glass broken.

• The product must be powered by an electrical system that is equipped with an effective earthing device.

• Switch the product off in the event of a fault or malfunction.

• Accumulated unburned pellets in the burner after each "failed start-up" must be removed before lighting again. Check that the burner is clean and positioned properly before lighting again.

• Do not wash the product with water. Water could get inside the unit and damage the electrical insulation and cause electric shocks.

• Do not stand for a long time in front of the product in operation. Do not overheat the room you are in and where the product is installed. This could cause injuries and health problems.

• Install the product in a location that does not present a fire hazard and is equipped with power and air supplies and smoke extractors.

• In the event of fire in the chimney, turn off the device, disconnect it from the mains electricity and do not open the hatch. Then contact the competent authorities.

• The product and the cladding must be stored in a dry place and must not be exposed to weathering.

• It is recommended not to remove the feet that support the product in order to guarantee adequate insulation, especially if the flooring is made of flammable materials.

• In the event of a malfunction of the ignition system, do not force it to light by using flammable materials.

• Special maintenance must only be performed by authorised and qualified personnel.

• Assess the static conditions of the surface on which the weight of the product will rest and provide suitable insulation if it is made of flammable material (e.g. wood, fitted carpet or plastic).

2

1-WARNINGS AND WARRANTY CONDITIONS

INFORMATION:

Please contact the retailer or qualified personnel authorised by the company to resolve a problem.

• You must only use the fuel specified by the manufacturer.

• When the product is switched on for the first time it is normal for it to emit smoke due to the paint overheating for the first time.

Therefore make sure the room in which it is installed is well ventilated.

• Check and clean the smoke extraction pipes regularly (connection to the chimney).

• The product is not a cooking appliance.

• Always keep the cover of the fuel hopper closed.

• Store this installation and use manual with care as it must accompany the product for the duration of its useful life. If the product is sold or transferred to another user, ensure the manual is also handed over.

INTENDED USE

The product only works with wood pellets and must be installed indoors.

WARRANTY CONDITIONS

The company guarantees the product, with the exception of elements subject to normal wear listed below, for a period of 2 (two) years from the date of purchase attested by:

• a document to serve as proof of purchase (invoice and/or receipt) that shows the name of the vendor and the date on which the purchase was made;

• forwarding of the completed certificate of guarantee within 8 days of purchase.

Furthermore, in order for the guarantee to be valid, the device must be installed and calibrated by qualified personnel, and where necessary, the user must be issued with a declaration of conformity and correct functioning of the product.

We recommend testing the product before completion with the relative finishes (claddings, painting of walls, etc.).

Installations that do not meet the current standards, improper use and lack of maintenance as expected by the manufacturer, void the product warranty.

The guarantee is valid on the condition that the instructions and warnings contained in the use and maintenance manual are observed, and therefore the product is used correctly.

The replacement of the entire appliance or the repair of one of its components does not extend the warranty period, and the original expiry date remains unchanged.

The warranty covers the replacement or free repair of parts recognised as faulty at source due to manufacturing defects.

To benefit from the warranty, in the event of a fault, the customer must have the warranty certificate and show it with the proof of purchase document to the Technical Assistance Office.

Technical Dept. - All rights reserved - Reproduction is prohibited 3

1-WARNINGS AND WARRANTY CONDITIONS

EXCLUSIONS

The guarantee does not cover malfunctions and/or damage to the appliance that arise due to the following causes:

• Damage caused during transportation and/or handling

• all parts that develop faults due to negligence or improper use, incorrect maintenance, installation that does not comply with the manufacturer's instructions (always refer to the installation and use manual provided with the appliance)

• incorrect sizing with regard to the use or faults in the installation or failure to adopt the necessary devices to guarantee proper execution

• improper overheating of the equipment, use of fuels not conforming to the types and quantities indicated in the instructions provided

• further damage caused by incorrect user interventions in an attempt to fix the initial fault

• worsening of the damage caused by the user continuing to operate the appliance even after the fault has been noticed

• in presence of a boiler, any corrosion, incrustations or breakages caused by water flow, condensation, hardness or acidity of the water, improperly performed descaling treatments, lack of water, mud or limescale deposits

• inefficiency of chimneys, flues or parts of the system affecting the appliance

• damage caused by tampering with the appliance, atmospheric agents, natural disasters, vandalism, electric shocks, fires, faults in the electric and/or hydraulic system.

Also excluded from this guarantee are:

• parts subject to normal wear such as gaskets, glass, claddings and cast iron grids, painted, chrome-plated or gilded parts, handles and electric cables, bulbs, indicator lights, knobs, all parts which can be removed from the hearth.

• Variations in colour of the painted or ceramic/serpentine parts and craquelure ceramics as they are natural characteristics of the material and product use.

• masonry work

• plant parts (if present) not supplied by the manufacturer

Any technical interventions on the product to eliminate the defects mentioned above and consequent damages must be agreed upon with the Technical Assistance Centre, who reserves the right to accept the relative appointment or not. However, said interventions will not be carried out under the guarantee but as technical assistance to be granted as part of any eventual and specific agreed conditions and in accordance with the fee applicable for the work to be carried out.

The user will also be charged for any costs incurred to remedy the incorrect technical interventions, tampering or damage to the appliance, not attributable to original faults.

With the exception of the legal or regulatory limits, the warranty does not cover the reduction of atmospheric and acoustic pollution.

The company declines all liability for any damage which may be caused, directly or indirectly, to persons, animals or objects as a consequence of non compliance with any provision specified in the manual, especially warnings regarding installation, use and maintenance of the appliance.

4

1-WARNINGS AND WARRANTY CONDITIONS

SPARE PARTS

In the event of a malfunction, consult the retailer who will forward the call to the Technical Assistance Service.

Only use original spare parts. The retailer or service centre can provide all necessary information regarding spare parts.

We do not recommend waiting for the parts to get worn out before having them replaced. It is important to perform regular maintenance.

The company declines all liability if the product and any other accessory is used improperly or modified without authorisation.

All parts must be replaced with original spare parts.

PRECAUTIONS FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE

2002/96/EC AND ITS SUBSEQUENT AMENDMENT 2003/108 EC.

At the end of its working life, the product must not be disposed of as urban waste.

It must be taken to a special differentiated waste collection centre set up by the local authorities or to a retailer that provides this service.

Disposing of the product separately prevents possible negative consequences for the environment and health deriving from inappropriate disposal and allows its materials to be recovered in order to obtain significant savings in energy and resources.

As a reminder of the need to dispose of appliances separately, the product is marked with a crossed-out wheeled dustbin.

Technical Dept. - All rights reserved - Reproduction is prohibited 5

1-WARNINGS AND WARRANTY CONDITIONS

RULES FOR INSTALLATION

The product in question is a stove that uses wood pellets.

Below is a list of European regulations regarding the installation of the product:

EN 12828 Heating systems design.

IEC 64-8 Electrical systems with rated voltage not exceeding 1000 V AC and 1500 V DC.

EN 1443 General chimney regulation

EN 1856-1 metal smoke ducts

EN 1856-2 metal smoke extraction channels

EN 1457 chimneys - Interior terracotta / ceramic flues

EN 13384-1 Chimneys - Thermal and dynamic fluid calculation methods - Part 1: Chimneys connected to a single appliance

Below are some applicable regulations for Italy:

UNI 10683:2012 Heat generators fuelled by wood or other solid bio-fuels - Test, installation, control and maintenance (for thermochemical power at the firebox lower than 35kW)

UNI/TS 11278 general technical regulation for the choice of smoke duct/flue

UNI 10847:2000 Smoke extractor systems for liquid and solid fuelled generators - Maintenance and control - Guidelines and procedures

UNI 8065 water treatment in civil plants.

UNI 9182 Hot and cold (sanitary) water supply and distribution systems.

Installation must be carried out with reference to the diagram of the heating system prepared in accordance with the standards and local recommendations in force:

In any case, respect:

For the heating appliance -

Local requirements concerning the chimney connection.

Local requirements for fire-fighting standards.

For electrical parts - EN 60335 ''Safety of electrical household appliances and similar"

Part 1 - General requirements

Part 2 - Special regulations for appliances with gas, gas oil and solid fuel burners with electrical connections.

6

2-FUEL

The instructions contained in this chapter explicitly refer to the regulations of the Italian installation Standard UNI 10683. In any case, always comply with the regulations in force in the country of installation.

PELLETS

Wood pellets are manufactured by hot-extruding compressed sawdust which is produced during the working of natural dried wood. The compactness of the material is guaranteed by the lignin contained in the wood itself and allows pellets to be produced without glue or binders.

The market offers different types of pellets with characteristics that vary according to the wood mixtures used. The diameter varies between 6 and 8 mm, with a standard length ranging from 5 to 30 mm. A good quality pellet has a density of between 600 and 750 or more kg/metres cubed and a water content that accounts for 5 to 8% of its weight.

Pellets have technical advantages besides being an ecological fuel, as the wood residue is used completely, thereby achieving cleaner combustion than that of fossil fuels.

While good-quality wood has a calorific value of 4.4 kW/kg (15% moisture, after about 18 months of seasoning), whereas that of pellets is around 4.9 kW/kg. To ensure good combustion, the pellets must be stored in a dry place and protected from dirt. Pellets are usually supplied in 15 kg bags, therefore, storing them is very convenient.

15 Kg BAG OF FUEL

Good quality pellets guarantee good combustion, thereby decreasing harmful emissions into the atmosphere.

The poorer the quality of the fuel, the more often the internal parts of the brazier and combustion chamber must be cleaned.

The main quality certifications for pellets currently available on the European market guarantee that the fuel complies with class A1/A2 according to EN14961-2. An example of these certifications are the ENPlus , DINplus , Ö-Norm M7135, and they guarantee that they are followed according to these characteristics:

• calorific value: 4,6 ÷ 5.3 kWh/kg.

• Water content: max 10% of weight.

• Percentage of ashes: max 1.5% of weight.

• Diameter: 5 ÷ 6 mm.

• Length: max 40 mm.

• Content: 100% untreated wood without the addition of binding substances (max 5% bark).

• Packaging: in sacks made from ecologically compatible or bio-degradable material.

The company strongly recommends using certified fuel for its products (ENplus, DINplus, Ö-Norm M7135).

Poor quality pellets or others that do not comply with the characteristics specified previously may compromise the operation of your product and can therefore make the guarantee and product liability invalid.

Technical Dept. - All rights reserved - Reproduction is prohibited 7

3-INSTALLATION

FOREWORD

The installation position must be chosen according to the room, to the smoke extraction system, to the chimney flue. Check with local authorities whether there are any restrictive regulations in force regarding the combustion air inlet, the smoke outlet system, the flue or the chimney cap. The manufacturer declines all responsibility in the event of installations that do not comply with the laws in force, incorrect room air exchange, electrical connection non-compliant with the standards and inappropriate use of the appliance. The installation must be carried out by a qualified technician, who must issue a declaration of conformity of the system to the purchaser and will assume full responsibility for final installation and consequent good operation of the product.

In particular one must ensure that:

• there is a suitable combustion air inlet and smoke outlet in compliance with the type of product installed

• other stoves or devices installed do not cause depression in the room where the product is installed (for sealed appliances only, a maximum of 15 Pa of depression in the room is allowed)

• when the product is switched on there is no reflux of smoke in the room

• fumes extraction takes place in total safety (sizing, smoke seal, distances from flammable materials..).

We especially recommend checking the data tags of the flue for the safety distances that must be observed in presence of combustible materials and the type of insulating material to be used. These indications must be followed strictly to prevent serious harm to people and the integrity of the home.

The installation of the appliance must ensure easy access to clean the appliance itself, the smoke outlet pipes and the flue. It is forbidden to install the stove in rooms with a fire hazard.

Installation in studio flats, bedrooms and bathrooms is only allowed with sealed or closed appliances equipped with suitable combustion air ducting directly outside. Always maintain adequate distance and protection in order to prevent the product from coming into contact with water.

In the event there are several appliances installed, the external air inlet must be sized accordingly.

MINIMUM DISTANCES

It is recommended to install the stove detached from any walls and/or furniture, with a minimum clearance to allow effective aeration of the appliance and a good distribution of heat in the room. Observe the distances from flammable or heat-sensitive objects (sofas, furniture, wood panelling, etc..) as specified. The front distance from flammable materials must be at least 1 metre.

If particularly delicate objects are present, such as furniture, curtains or sofas, increase the stove clearance accordingly.

If the floor is made of wood, it is recommended to fit a floor protection sheet in compliance with the Standards in force in the country of installation.

A

Non-flammable walls Flammable walls

DUO HYDRO AIR

A = 5 cm

B = 5 cm

A = 10 cm

B = 10 cm

B

If the floor is made of combustible material, it is recommended to use protection made of non-combustible material (steel, glass...) that also protects the front from falling combusted material during cleaning operations.

The appliance must be installed on a floor with adequate load capacity.

If the existing construction does not meet this requirement, one must take appropriate measures (for example a load distribution plate).

8

4-FLUE

FOREWORD

The Chimney Flue chapter has been drawn up with reference to the provisions of European Standards (EN13384 - EN1443 - EN1856 -

EN1457).

The chapter provides instructions for installing a chimney flue efficiently and properly, but under no circumstances is it a substitute of the

Standards in force, which the qualified technician must be in possession of. Check with local authorities whether there are any restrictive regulations in force regarding the combustion air inlet, the smoke outlet system, the flue or the chimney cap.

The company declines all liability relating to the poor functioning of the stove if this is due to the use of an insufficiently sized flue in violation of the Standards in force.

SMOKE FLUE

The flue or chimney is of great importance for the proper operation of a solid fuel-burning heating appliance with natural draught, as modern heating appliances have high efficiency with cooler flue gasses and consequently less draught, it is therefore essential that the flue is built up to standard and always kept in perfect working order. A flue that serves a pellet/wood fuelled appliance must be at least category T400 (or greater if the appliance requires so) and resistant to soot fires. Smoke must be extracted through a single flue made of insulated steel (A) or an existing flue that complies with the intended use (B).

A simple air shaft made of cement must be suitably lined. In both solutions there must be an inspection cap (AT) and/or inspection hatch

(AP) - FIG.1.

It is forbidden to connect more than one wood/pellet-burning appliance or of any other kind (vent hoods... ) to the same flue.

(A)

AT

FIGURE 1 - SMOKE FLUE

Technical Dept. - All rights reserved - Reproduction is prohibited

(B)

AP

9

3-INSTALLATION

TECHNICAL CHARACTERISTICS

Have the efficiency of the flue checked by an authorised technician.

The flue must be sealed against flue gasses, in a vertical direction without narrowing, be made with materials impermeable to smoke, condensation, thermally insulated and suitable to resist normal mechanical stress over time (we recommend fireplaces made of A/316 or refractory material with insulated round section double chamber). Be suitably insulated externally to avoid condensation and reduce smoke cooling. It should be separated from combustible or flammable materials with an air gap or insulating materials: check the distance specified by the manufacturer of the fireplace according to EN1443. The chimney opening must be in the same room as the appliance, or at most in the adjoining room, and have a soot and condensation collection chamber beneath the opening, and be accessible via a watertight metal hatch.

FLAT ROOF

A B

E

C

D

A = 0.50 metres

B = DISTANCE > 2 metres

C = DISTANCE < 2 metres

D = 0.50 metres

E = TECHNICAL VOLUME

FIGURE 2

ROOF AT 15°

A

ROOF AT 30°

B

C

15°

D

E

F

A = MIN. 1.00 metres

B = DISTANCE > 1.85 metres

C = DISTANCE < 1.85 metres

D = 0.50 metres above highest point

E = 0.50 metres

F = REFLUX AREA

FIGURE 3

B

C

D

A = MIN. 1.30 metres

B = DISTANCE > 1.50 metres

C = DISTANCE < 1.50 metres

D = 0.50 metres above highest point

E = 0.80 metres

F = REFLUX AREA

A

F

E

30°

FIGURE 4

10

3-INSTALLATION

ROOF AT 60° ROOF AT 45°

B

C

B

D

C

D

A

60°

E

F A

45°

E F

A = MIN. 2.60 metres

B = DISTANCE > 1.20 metres

C = DISTANCE < 1.20 metres

D = 0.50 metres above highest point

E = 2.10 metres

F = REFLUX AREA

FIGURE 5

A = MIN. 2.00 metres

B = DISTANCE > 1.30 metres

C = DISTANCE < 1.30 metres

D = 0.50 metres above highest point

E = 1.50 metres

F = REFLUX AREA

FIGURE 6

SIZING

The depression (draught) of a flue depends on its height. Check the depression with the values indicated in the technical characteristics.

The minimum height of the chimney is 3.5 meters.

The interior cross-section of the flue can be round (best), square or rectangular (the ratio between the internal sides must be ≤1.5) with the sides joined with a minimum radius of 20 mm. The dimension of the cross-section must be minimum Ø100mm .

The cross sections/lengths of chimneys must be correctly sized in accordance with the general method of calculation of UNI EN13384-1 or other methods of proven efficiency.

Below is a list of some flues available on the market:

AISI 316 steel chimney with double chamber insulated with ceramic fibre or equivalent resistant up to

400°C.

Refractory chimney with double insulated chamber and external lightweight concrete cladding with cellular material such as clay.

Traditional square-section clay chimney with insulating

Avoid products with an internal rectangular section empty inserts.

where the larger side is 1.5 times the smaller side (e.g.

20x40 or 15x30).

EXCELLENT GOOD POOR VERY POOR

Technical Dept. - All rights reserved - Reproduction is prohibited 11

3-INSTALLATION

MAINTENANCE

The flue must be kept clean, since the deposit of soot or unburned oils reduces the cross-section reducing the draft and thus compromising the efficient operation of the stove and, if large build-ups accumulate, can catch fire. The flue and chimney must be cleaned and checked by a qualified chimney sweep at least once a year. Once maintenance has been performed, request a written declaration that the system is safe.

Failure to clean the system jeopardises safety.

CHIMNEY CAP

The chimney cap is a crucial element for the heating appliance to work properly: we recommend a wind proof chimney cap (A), see Figure

7.

The area of the openings for smoke extraction must be at least double the cross-section of the smoke duct/flue system, and arranged so that smoke extraction is ensured even in strong wind.

The chimney must prevent rain, snow or animals from entering the chimney. The height of outflow into the atmosphere must be beyond the reflux area due to the shape of the roof or any obstacles near the outlet (see Figures 2-3-4-5-6).

FIGURE 7

CHIMNEY COMPONENTS

3

4

5

9

1

2

KEY:

(1) CHIMNEY CAP

(2) REFLUX CHANNEL

(3) SMOKE DUCT

(4) THERMAL INSULATION

(5) OUTSIDE WALL

(6) CHIMNEY CONNECTION

(7) SMOKE CHANNEL

(8) HEAT GENERATOR

(9) INSPECTION ACCESS PANEL

7

6

FIGURE 8

8

9

9

12

3-INSTALLATION

EXTERNAL AIR INLET

It is mandatory to provide an adequate external air intake that supplies the combustion air required for the product to work properly. The flow of air between the outside and the installation room may be direct, through an inlet in an external wall of the room; or indirect, via air intake from adjoining rooms and connecting permanently with the installation room (see Figure 9 b). Adjoining areas may not include sleeping areas, garages or general areas with a fire hazard. During installation one must check the minimum clearances required for air intake from outside. Take into account the presence of doors and windows that could interfere with the proper flow of air to the stove

(see diagram below).

The air intake must have a minimum total net area of 80 cm2: the surface must be increased accordingly if within the room there are other active generators (for example: electric fan for stale air extraction, kitchen hood, other stoves, etc...), which could cause a depression in the room. One must verify that, with all the equipment on, the pressure drop between the room and the outside does not exceed a value of 4 Pa. If necessary increase the intake section of the air inlet, which must be made at floor level and always protected with a bird-proof outer protection grid and in such a way that it cannot be obstructed by any object.

B B

FIGURE 9 A - DIRECTLY FROM OUTSIDE

A

MIN.1,5 m MIN.1,5 m

MIN.0,3 m

MIN.1,5 m

Technical Dept. - All rights reserved - Reproduction is prohibited

C A

FIGURE 9 B - INDIRECTLY FROM THE ADJACENT ROOM

A=AIR INLET

B=ROOM TO BE VENTILATED

C=INCREASE OF THE GAP UNDER THE DOOR

It is possible to connect the air required for combustion directly to the outside air inlet, with a pipe of at least Ø50mm, with maximum length of 3 linear metres; each pipe bend shall be considered equivalent to a linear metre. To attach the pipe see the back of the stove.

For stoves installed in studio flats, bedrooms and bathrooms (where allowed), it is mandatory to connect the combustion air outside. In particular for sealed stoves the connection must be sealed in order not to compromise the overall sealed characteristic of the system.

FIGURE 10

13

3-INSTALLATION

DISTANCE (metres)

1.5 m

1.5 m

0.3 m

1.5 m

The air inlet must be at a distance of:

UNDER Windows, doors, smoke outlets, cavities, ....

HORIZONTALLY Windows, doors, smoke outlets, cavities, ....

ABOVE

AWAY

Windows, doors, smoke outlets, cavities, ....

from smoke outlet

CONNECTION TO THE FLUE

The connection between the flue and the appliance must be via a smoke duct that complies with EN 1856-2. The connecting section must extend no more than 4 m horizontally, with a minimum slope of 3% and with a maximum of 3 90% bends (accessible for inspection - do not count the T fitting at the appliance outlet).

The diameter of the smoke duct must be equal to or greater than that of the appliance outlet (Ø 80 mm).

TYPE OF SYSTEM

Minimum vertical length

Maximum length

(with 1 accessible 90° bend)

Maximum length

(with 3 accessible 90° bends)

Maximum number of accessible 90° bends

Horizontal sections

(minimum slope 3%)

SMOKE DUCT

1.5 metres

6.5 metres

4.5 metres

3

4 metres

Use a smoke duct according to current regulations in the country of installation that is compatible to product and installation characteristics.

The temperature class of the smoke duct must exceed operating temperatures of the appliance.

It is forbidden to connect several appliances to the same smoke duct, or the outlet from the overhead hoods. It is forbidden to extract the combustion products directly through the wall, whether into indoor spaces or outdoors.

With flammable or heat-sensitive structures present, the smoke duct must respect the safety distances specified in the data plate.

14

3-INSTALLATION

EXAMPLES OF CORRECT INSTALLATION

2

I

U

S

C

A

B

P

1

E

D

V

U

I

I

4

T

F

1.

Installation of Ø120mm flue with hole for the passage of the pipe increased by: minimum 100 mm around the tube if next to non flammable parts such as cement, brick, etc.; or minimum 300mm around the pipe (or as required by data tags) if next to flammable parts such as wood etc.

In both cases, install suitable insulation between the flue and the ceiling.

Always check and respect the data tags on the flue, in particular the minimum safety distances from combustible materials.

The previous rules also apply for holes made in walls.

2.

Old flue, minimum pipe Ø100mm with the inclusion of an external access door for chimney cleaning.

3.

External flue made of insulated stainless steel pipes, i.e. with double walls minimum Ø100mm: all securely mounted on the wall. With wind-proof chimney cap. See fig. 7 type A.

4.

Ducting system using T fitting that allows easy access for cleaning without having to remove the pipes

3

FIGURE 11

U

I

I

U = INSULATING

V = ANY REDUCTION FROM 100 TO 80 MM

I = INSPECTION CAP

S = INSPECTION ACCESS PANEL

P = AIR INLET

T = T JOINT WITH INSPECTION CAP

A = MINIMUM 40 MM

B = MAXIMUM 4 M

C = MINIMUM 3°

D = MINIMUM 400 MM

E = HOLE DIAMETER

F = SEE FIG.2-3-4-5-6

Technical Dept. - All rights reserved - Reproduction is prohibited 15

5-DRAWINGS AND TECHNICAL FEATURES

DRAWINGS AND CHARACTERISTICS

DUO HYDRO - AIR STOVE DIMENSIONS

043

080

187

413

226

417

080 048

582

16

5-DRAWINGS AND TECHNICAL FEATURES

TECHNICAL CHARACTERISTICS

Nominal output power

Nominal output power (H

Minimum output power

Minimum output power (H

2

O)

2

O)

Efficiency at Max

Efficiency at Min

Temperature of exhaust smoke at Max

Temperature of exhaust smoke at Min

Particles/OGC/Nox (13%O

2

CO at 13% O

2

CO

2

)

at Min and at Max

at Min and at Max

Smoke mass

Max operating temperature

Recommended draught at Max power

Recommended draught at Min power

Hopper capacity

Type of pellet fuel

Pellet hourly consumption

Autonomy

Heatable volume m 3

Combustion air inlet

Smoke outlet

Air inlet

Rated electrical power (EN 60335-1)

Supply voltage and frequency

Net weight

Weight with packaging

Distance from flammable material (back)

Distance from flammable material (side)

DUO HYDRO-AIR

22.3 kW (19,178 kcal/h)

18.0 kW (15,480 kcal/h)

4.4 kW (3,784 kcal/h)

3.0 kW (2,580 kcal/h)

92,5%

95,0%

160°C

71°C

2 mg/Nm3 - 0.2 mg/Nm3 - 132 mg/Nm3

0,040 – 0,012%

7,03% - 12,49%

12.6 g/sec

2.5 bar - 250 kPa

0.10 mbar - 10 Pa

0.05 mbar - 5 Pa

44 litres

Pellet diameter 6-8 mm and size 5/30 mm

Min ~ 0.9 kg/h* - Max ~ 4.9 kg/h*

At min ~ 28 h* - At max ~ 5 h*

481/40 – 550/35 – 642/30 **

Ø 50 mm

Ø 80 mm

80 cm2

120 W (Max 420 W)

230 Volt / 50 Hz

190 kg

200 kg

100 mm

100 mm

* Data that may vary depending on the type of pellets used

** Volume that can be heated, according to the power requirement per m 3 (respectively 40-35-30 Kcal/h per m 3 )

Tested according to EN 14785 in accordance with European regulation for Construction Products (UE 305/2011)

Technical Dept. - All rights reserved - Reproduction is prohibited 17

6-INSTALLATION AND ASSEMBLY

PREPARATION AND UNPACKING

The packaging consists of a recyclable cardboard box according to RESY standards, recyclable EPS foam inserts, wooden pallets. All packaging materials can be reused for similar use or eventually disposed of as urban solid waste, in compliance with the regulations in force.

After having removed the packaging make sure the product is intact.

Handle the product with suitable means paying attention to the applicable safety regulations in force. Do not turn the packaging over and handle the ceramic parts with care.

The DUO stove is delivered with two overlapping packaging:

• the first contains the stove structure (fig. 1).

• the second (fig.2) contains the box with the ceramic cladding (1 top, 2 front panels, 6 side panels)

Open the packaging, remove the two screws on the right and the two screws on the left (see figure 4) that secure the base of the stove to the pallet, and position the stove in the selected place, ensuring that it is complies with the above instructions.

FIGURE 2 - CERAMIC PANEL

PACKAGING

FIGURE 1 - REMOVING PACKAGING

SCREWS

18

6-INSTALLATION AND ASSEMBLY

The stove body or unit must always be kept in a vertical position when handled, and handled using carts only. Pay particular attention to the door and its glass, protecting them from mechanical knocks that would compromise their integrity.

The product must always be handled with care. If possible, unwrap the stove near the chosen area of installation.

The packaging materials are neither toxic nor harmful, therefore no particular disposal measures are required.

Therefore, the end user is responsible for product storage, disposal or possible recycling in compliance with the relative applicable laws in force. Do not store the unit/stove or its cladding without their packaging.

Position the stove and connect it to the flue pipe. Use the four adjustable feet (J) to get the stove correctly levelled so that the smoke outlet (S) is lined up with the connecting pipe (H) .

If the stove needs to be connected to an outlet pipe which goes through the rear wall (to connect to the flue), take utmost care to make sure that the joint is not forced.

If the stove smoke outlet is forced or used improperly to lift it or position it, the operation of the stove can be damaged irreparably.

H

S

Technical Dept. - All rights reserved - Reproduction is prohibited

J

J

1. TURN THE FEET CLOCKWISE TO LOWER THE STOVE

2. TURN THE FEET COUNTER CLOCKWISE TO LIFT THE STOVE

19

6-INSTALLATION AND ASSEMBLY

ASSEMBLING THE FRONT AND SIDE CLADDING

The stove is delivered with all ceramic parts packaged and therefore, before installing the side tiles and the top, it is necessary to insert the front panels.

In order to insert the front panel it is necessary to work on the right side of the stove (handle side) and proceed as follows:

• Remove the micro-perforated sheet metal grille "B" removing the two screws "c" (fig.3).

• Remove the two screws “d”, lift and remove the bracket“E” (fig.4) c d

B

E

20

FIGURE 3 - REMOVAL OF GRILLE B FIGURE 4 - REMOVAL OF E BRACKET

A

6-INSTALLATION AND ASSEMBLY

• Lift profile “A” to remove it from the base and place it in a safe position (fig.5)

FIGURE 5 - REMOVAL OF PROFILE A

A

Technical Dept. - All rights reserved - Reproduction is prohibited

A

21

6-INSTALLATION AND ASSEMBLY

• Take the two front ceramic pieces “F” and “G” and insert them on the right (handle side) towards the left so that they fit exactly in the seat (fig.6)

FIGURE 6 - ASSEMBLY OF FRONT CERAMIC PANELS “F” - “G”

G

A

F

22

6-INSTALLATION AND ASSEMBLY

• After inserting ceramic pieces “F” and “G”, reinsert profile “A”, bracket “E” tightening the two screws “d” (fig.7).

FIGURE 7 - ASSEMBLY OF PROFILE “A” AND BRACKET “E” d

E

G

F

Technical Dept. - All rights reserved - Reproduction is prohibited

A

23

6-INSTALLATION AND ASSEMBLY

• At this point insert side ceramic pieces “R”, “S”, “T” (fig.8) sliding them from the top towards the bottom on the guide of profile “A”.

ATTENTION!

On the top and lower part of the ceramic tile we recommend placing small pieces of felt in order to avoid that the ceramic tiles break and also to level the spacing if necessary.

FIGURE 8 - SIDE PANEL ASSEMBLY

R

S

T

24

6-INSTALLATION AND ASSEMBLY

On the left side (opposing the handle - fig.9) remove the micro-perforated grille "B" from the structure removing the two screws "c".

Insert the three ceramic pieces “U”, “V”, “Z” sliding them from the top towards the bottom on the guide of profile “A”.

ATTENTION!

On the top and lower part of the ceramic tile we recommend placing small pieces of felt in order to avoid that the ceramic tiles break and also to level the spacing if necessary.

c

U

B

A

FIGURE 9 - SIDE PANEL ASSEMBLY

Technical Dept. - All rights reserved - Reproduction is prohibited

V

Z

A

25

26

6-INSTALLATION AND ASSEMBLY

At this point it is possible to screws the micro-perforated grilles "B" (fig.10) to the structure and proceed with top positioning.

FIGURE 10 - ASSEMBLY OF GRILLES “B”

B

B

6-INSTALLATION AND ASSEMBLY

ASSEMBLY OF THE CERAMIC TOP

Assemble the top "K" resting it on the four top rubber supports (see details below - fig.12) of the stove. The part under the ceramic top is equipped with four small cavities corresponding with the rubber supports.

FIGURE 11 - TOP ASSEMBLY

K

FIGURE 12 - DETAIL OF TOP RUBBER SUPPORTS

Technical Dept. - All rights reserved - Reproduction is prohibited 27

6-INSTALLATION AND ASSEMBLY

LOADING THE PELLETS

Fuel is loaded from the upper part of the stove by lifting the door. Pour the pellets into the hopper.

This is easier if performed in two steps:

Pour half of the contents into the hopper and wait for the fuel to settle on the bottom.

Then pour in the rest.

Never remove the protection grid inside the hopper. When loading, do not let the pellet bag come into contact with hot surfaces.

No other type of fuel other than pellets is to be inserted into the hopper, in compliance with above-mentioned specifications.

Store the spare fuel at an adequate safe distance.

Do not pour pellets directly onto the brazier but only into the hopper.

Most of the stove surfaces are very hot (door, handle, glass, smoke outlet pipes, hopper door etc.), therefore it is recommended to avoid coming into contact with these parts without appropriate protective clothing.

LOADING THE PELLETS

CONDUIT FOR THE AUXILIARY TANK (optional)

It is possible to purchase conduit to be fastened, using four screws, to the back of the stove, in correspondence of the knock-out panel, first the square and then the round piece is to be removed.

This conduit makes it possible to insert pellets into the tank through an auxiliary tank (not supplied).

1

2

28

7 - HYDRAULIC CONNECTION

PLUMBING SYSTEM CONNECTION

IMPORTANT!

The connection of the stove to the plumbing system must be carried out ONLY by specialized personnel who are capable of carrying out installation properly, in compliance with current standards in the country of installation.

The manufacturer will not be held responsible for damage to persons or things in the event of failed operation if the aforementioned warning is not complied with.

CONNECTION DIAGRAM

C

E

A1 Heating water supply 3/4”M

A2 Heating water return 3/4”M

3 bar safety shut off valve– 1/2”F

System emptying device 1/2”F

C E A1 A2

67 50

169 55 60 106 187

IMPORTANT!!!

CLEAN THE ENTIRE SYSTEM BEFORE CONNECTING THE STOVE, IN ORDER TO REMOVE ALL RESIDUE AND DEPOSITS.

Upstream from the stove, always install shutters so as to disconnect it from the plumbing system should it be necessary to move it, or when it requires routine and/or special maintenance.

Connect the stove using hoses so that the stove is not too strictly connected to the system, and to allow slight movements.

Technical Dept. - All rights reserved - Reproduction is prohibited 29

7 - HYDRAULIC CONNECTION

CONNECTING THE SYSTEM

Make the connections to the corresponding fittings shown in the diagram on the previous page. Make sure the pipes are not placed under tension or undersized.

IT IS STRONGLY RECOMMENDED TO WASH THE ENTIRE SYSTEM BEFORE CONNECTING THE STOVE IN ORDER TO GET RID

OF RESIDUES AND DEPOSITS.

Upstream from the stove, always install shutters so as to disconnect it from the plumbing system should it be necessary to move it, or when it requires routine and/or special maintenance. Connect the stove using hoses so that the stove is not too strictly connected to the system, and to allow slight movements.

The pressure discharge valve (C) is always connected to a water drain pipe. The pipe must be adequate to support the water's high temperature and pressure.

CLEANING THE SYSTEM

It is mandatory for the connections to be easy to disconnect by way of unions with rotating connection.

Install suitable shutters to cut off the tubes from the heating system. Assembling the safety valve on the system is compulsory.

In order to protect the heating system from damage caused by corrosion, incrustation or deposit build-up, it is important to clean the appliance before installation, using suitable products, in compliance with Standard UNI 8065 (water treatment of thermal plants for civil use) .

The use of FERNOX PROTECTOR F1 (available at our authorised centres) product is recommended, this provides long term protection against corrosion and calcium build-up for heating systems. It prevents the corrosion of the metal parts of the appliance, i.e. the ferrous metals, copper and copper and aluminium alloys. It also reduces the noise produced by the boiler. Refer to the instructions on the product.

Cleaning should be performed by a qualified technician.

We also recommend the use of FERNOX CLEANER F3 and LEAK SEALER F4, always available from our authorised distribution centres.

FERNOX F3 is a neutral product for rapid and efficient cleaning of heating appliances. It has been designed to eliminate residues, oily deposits and incrustations from existing appliances of all ages. It can help restore the heating efficiency of the boiler and reduce the noise it generates.

FERNOX F4 is intended to be used with all heating appliances to seal micro fractures that cause small and inaccessible leaks.

FILLING THE SYSTEM

To fill the system, the stove can be equipped with an end piece (optional) with a non-return valve (D) , for manual filling of the heating system (if the option is not installed, the filling tap on the main boiler will be used). During this operation, any air in the system is released from the automatic vent valve located under the top.

To ensure the valve vents, it is advisable to loosen the grey cap one turn and leave the red cap blocked (see figure). The filling pressure of the system WHEN COLD must be 1 bar . During operation, if the system pressure drops (due to evaporation of dissolved gases in the water) to values lower than the minimum indicated above, the user must use the filling tap to bring the pressure back up to its normal pressure.

For proper operation of the stove WHEN HOT , the pressure in the boiler must be 1.5 bar .

To monitor system pressure, the end piece (optional) is equipped with a pressure gauge (M) .

Upon completion of this operation, always close the tap.

30

7 - HYDRAULIC CONNECTION

END PIECE WITH A FILLING TAP

(D) AND PRESSURE GAUGE (M)

(ACCESSORY)

VENT VALVE UNDER THE TOP

WATER CHARACTERISTICS

The characteristics of the water used to fill the system are very important to prevent the build-up of mineral salts and the formation of incrustations along the pipes, in the boiler and in the heat exchangers.

Therefore, please GET YOUR PLUMBER'S ADVICE CONCERNING:

• Hardness of water circulating in the system, to prevent problems of incrustation and limescale, especially in the domestic water heat exchanger. (> 25° French).

• Installation of a water softener (if water hardness exceeds 25° French).

• Filling the system with treated water (demineralised).

• Possibly providing an anti-condensation circuit.

• Installation of plumbing bumpers to prevent banging along the fittings and pipes.

If you have very extensive systems, with a large amount of water, or which require frequent refilling, the installation of water softening systems.

It should be remembered that incrustations drastically reduce performance due to low thermal conductivity.

Technical Dept. - All rights reserved - Reproduction is prohibited 31

8-ELECTRICAL CONNECTION

ELECTRICAL CONNECTION

First connect the power cable to the back of the stove and then to a wall socket.

The main switch must only be activated to switch the stove on; otherwise, it is advisable to keep it switched off.

It is recommended to disconnect the power cable when the stove is not used.

ELECTRICAL STOVE CONNECTION

STOVE POWER SUPPLY

After connecting the power cable to the back of the stove, turn the switch at the back to position ( I ).

The luminous switch button will light up.

The switch on the back of the stove is used to power the system.

On the rear of the stove there is a fuse holding compartment which is located underneath the supply socket. Use a screwdriver to open the

STOVE POWER SUPPLY

FUSE HOLDER COMPARTMENT

STOVE SWITCH fuse-holder compartment and if necessary replace them (3.15 A delayed)

32

8-PRECAUTIONS BEFORE START-UP

GENERAL PRECAUTIONS

Remove any objects that may burn from the brazier (manual, various adhesive labels or any polystyrene).

Check that the brazier is positioned correctly and rests properly on the base.

The first start-up may not be successful as the feed screw is empty and does not always manage to load the required amount of pellets in time to light the flame.

CANCEL THE FAILED IGNITION ALARM. REMOVE THE PELLETS LEFT IN THE BRAZIER AND REPEAT THE START-UP.

If after repeated attempts, the flame fails to ignite, despite a regular flow of pellets in the brazier, which must rest snugly against the slots and be clean without any ash incrustations.

If no anomaly is found during this inspection, there may be a problem with the product components or installation may not be correct.

REMOVE THE PELLETS FROM THE BRAZIER AND CONTACT AN AUTHORISED TECHNICIAN.

Do not touch the boiler during the first lighting, as it is during this phase that the paint sets. If you touch the paint, you may expose the steel surface.

If necessary, touch up the paint with the spray can of the specific colour. (See "Pellet stove accessories").

It is good practice to ensure effective ventilation in the room during the initial start-up, as the boiler will emit some smoke and smell of paint.

Do not stand close to the stove and, as mentioned, air the room. The smoke and smell of paint will disappear after about an hour of operation, however, they are not harmful in any case.

The boiler will be subject to expansion and contraction during the lighting and cooling down stages, and may therefore make slight creaking noises.

This is absolutely normal as the structure is made of laminated steel and must not be considered a defect.

It is extremely important to make sure the boiler does not reach high temperatures straight away, but to increase the temperature gradually using low power at first.

This will prevent damaging the ceramic or serpentine stone tiles, the welds and the steel structure.

DO NOT EXPECT HEATING EFFICIENCY IMMEDIATELY!!!

Technical Dept. - All rights reserved - Reproduction is prohibited 33

9 - CONTROL PANEL

CONTROL PANEL DISPLAY

A

B C

MENU

D E

KEY

A - DISPLAY; indicates a series of information on the stove, as well as the identification code of any malfunction.

B - Function selection key indicated by the upper display (i.e. start-up/shutdown)

C - Function selection key indicated by the upper display (i.e. increase/scrolling)

D - Function selection key indicated by the upper display (i.e. decrease/scrolling)

E - Function selection key indicated by the upper display (i.e. menu)

34

10 - FIRST START-UP

INITIAL START-UP

REV.SOFTWARE NUM BANCA DATI

At initial start-up, after connecting the power cable and pressing the I/O button, the stove display will show wording for the software version and database number (after a few seconds it will move on to the next screen).

If the language has already been set, the next screen will be OFF, otherwise one enters the following parameter.

SELECT LANGUAGE

At initial start-up, if it has never been set, the LANGUAGE choice screen appears.

The system displays all possible languages.

Using the arrow keys (C, D) scroll the languages and confirm the desired language using the “E” (OK) key.

LANGUAGE

ITALIANO

ENGLISH

ESPANOL

OK

C D E

SETTING TIME AND DAY

The keys that are active for this function: “C”, “D”, “E”. The C-D keys are used to choose time or day while the E key is used to confirm.

OGGI È LUNEDÌ E SONO LE

21.25

MODIFICA

GIORNO

MODIFICA

ORA

OK

C D E C

Technical Dept. - All rights reserved - Reproduction is prohibited

OGGI È LUNEDÌ E SONO LE

21.25

OK

D E C

OGGI È LUNEDÌ E SONO LE

21.25

OK

D E

35

9 - CONTROL PANEL

SCREEN OFF

If a LANGUAGE has already been set, the display will go to OFF.

Pressing any one of the keys (B, C, D, E) will result in the first screen showing OFF to be displayed. From this screen, pressing keys "B" and

"E" (respectively corresponding to ON and MENU) it is possible to access the panel or the menu. If no key is pressed, the display will once again show OFF after 5 seconds.

ON

OFF

ECO

MENU

OFF-DISPLAY OFF

B

OFF-DISPLAY ACTIVE

E

PRELIMINARY OPTIONS

Hydro Air stoves are characterised by the presence of a heating hydraulic circuit and a room air fan for distributing hot air.

The possibility of deviating the hydraulic circuit towards a finned copper exchanger based on user request or automatically to double the amount of heat distributed to the room air (also see HYDRO AIR SETTINGS MENU).

Room fan

The speed can be set manually or automatically.

In manual mode the speed, from 0 to 5, is chosen by the user from the control panel. The fan is only activated if the air output temperature exceeds 42°C and is deactivated when it goes below 40°C; while at speed 0 the fan is off.

In automatic the stove adjusts fan speed in order to obtain stable output air temperature (approximately 55°C in Hydro Air On mode and

ESCI

IMPOSTA VENTILAZIONE

OK

B C D E

45°C in Hydro Air Off mode), optimising acoustic comfort with an equal power provided. Even in this case the fan is only activated if air temperature exceeds 42°C.

For greater comfort, maximum fan speed in automatic mode corresponds to 3 and shuts off only if the temperature falls below 40°C.

ESCI

IMPOSTA VENTILAZIONE

AUTO

OK

B E

36

9 - CONTROL PANEL

Lighting the stove

To switch on the stove, keep the "B" (ON) key on the panel pressed. The stove starts an ignition procedure that brings the flame to a suitable level to Supply Power.

ON

OFF

ECO

MENU

B

Supplying power

The stove's power supply is signalled by "power level bars": one bar corresponds to minimum power, 5 bars to maximum power, this level is determined by the heating system heat requirements, the stove adjusts pellet loading parameters, fumes extraction and combustion air flow to comply with this requirement.

1

10:13 TIMER1 ECO

25°

23° AUTO

OFF TEMP VENT MENU

TOP BAR: active requirements, active programs, power bar, functions

CENTRAL BAR: room temperature, room set, room fan bar

BOTTOM BAR/KEYS: shut-off "B", temperature set modify "C" and fan set "D", menu "E"

1 = power level bars

B C D E

Technical Dept. - All rights reserved - Reproduction is prohibited 37

11 - MENU STRUCTURE

MENU STRUCTURE

To enter MENU press the "E" key (MENU).

OFF

ON

ECO

MENU

Next, this screen with the following functions is displayed:

E

TEMPERATURE

INFORMAZIONI

ESCI

PROGRAMMI

IMPOSTAZIONI

OK

Sub-menu

TEMPERATURE

PROGRAMMES

INFORMATION

SETTINGS

B C D E

TEMPERATURE (hydro air)

When accessing this function, the main screen makes it possible to set heating and sanitary water temperature (if boiler with probe configured - see menu settings input aux).

Select what is to be set and then using the C and D keys increase/decrease the temperature, use the E key to confirm while the B key is used to exit and return to the main MENU.

ESCI

TEMPERATURE

OK ESCI

TEMPERATURA

71°

OK

TEMPERATURA ACCUMULO

50°

ESCI OK

B C D E

PROGRAMMES

In this case it is possible to choose the programme to be set.

Programme selection makes it possible to choose between one of the following options (one choice excludes the other):

TIMER 1

TIMER 2

MANUAL

TEMP. LEVELS

SLEEP FUNCT.

38

11 - MENU STRUCTURE

TEMPERATURE

INFORMAZIONI

ESCI

PROGRAMMI

IMPOSTAZIONI

OK

SELEZIONE PROGRAMMA

TIMER 1 TIMER 2 MANUALE

LIVELLI TEMP

ESCI ATTIVA

FUNZ. SLEEP

ENTRA

B C D E

In the MENU screen, move the cursor with arrows "C"-"D" and select PROGRAMS, press ok "E" to confirm. Next select the programme you wish to set.

Once completed, always press “ACTIVATE” to confirm the choice of programme.

The TIMER 1 and 2 programmes are freely programmable for each 1/2 hour of the day on three different temperature indicators (T1-T2-T3) and in different ways for each day of the week. The OFF level requires that the stove is switched off in that interval.

TIMER 1

0 6 12 18

LUNEDI’ MARTEDI ‘ MERCOLEDI’

ESCI COPIA

24

OK

TIMER 1

0

LUNEDI’

SALVA

6 12 18 24

10:00 20°C

6 12

10:00

T3

T2

T1

B C D E

Example of temperature programming for Monday .

Select the TIMER 1 item from the PROGRAM menu and press the ENTRA (ENTER) “E” key, using arrow “D” highlight Monday and press OK

(“E”) to enter programming.

Using the centre arrow keys “C” and “D” select the half hour interval to be selected and use the “E” key to set temperature T1-T2-T3

(depending on whether the key is pressed 1-2-3 times the corresponding temperature can be read in the bottom right of the display).

Once temperature programming for Monday is complete press the "B" SALVA (SAVE) key. If the same temperature scale of Monday is desired for other week days, after saving ("E" key) press the "C" key (COPIA-COPY), select the day where the program is to be copied using the "D" key and press the "C" key (INCOLLA-PASTE). Repeat the same procedure until the programmes for all the days of the week are complete. At this point the stove is programmed according to your temperature needs, which can be modified at any time.

CAUTION:

In order to make stove use easier, MCZ supplies Timer 1 with preset weekly temperatures and times (according to the table below), while

Timer 2 is available. In any case, it is possible to change times and temperatures of Timer 1 at any time.

PANEL OFF DISPLAY FROM TIMER

When timer 1 (for example) has no set temperature, the panel highlights that the stove is in OFF position.

OFF

03:33 TIMER 1

16° OFF

MENU

If the stove is off by MANUAL command, the timer will have no effect.

For the stove to come on with the timer, the panel must display the image shown on the side; if this should not be the case, it may be necessary to press the ON (“B”) key.

Technical Dept. - All rights reserved - Reproduction is prohibited 39

11 - MENU STRUCTURE

15:00

14:00

13:00

12:00

11:00

10:00

09:00

19:00

18:00

17:00

16:00

23:00

22:00

21:00

20:00

04:00

03:00

02:00

01:00

00:00

08:00

07:00

06:00

05:00

* T1=16°C T2=20°C T3=22°C OFF=switched off

40

11 - MENU STRUCTURE

MANUAL

This function can be activated from the menu PROGRAMME by pressing the key "C" ACTIVE. When this function is activated the stove no longer follows time programming of TIMER 1 or 2 programmes, but it keeps the temperature set in the main screen throughout the 24 hour time period. It is possible to switch to programmes at any time.

TEMPERATURE LEVELS

LIVELLI TEMPERATURA

T1

T2

T3

16°

20°

22°

OK

It is possible to change the 3 temperature levels referenced by timers in this menu.

From the PROGRAMS menu use arrow key "D" to move and select TEMP LEVELS, press the "E" keys and enter the temperature settings screen. With the centre arrow keys "C" and "D" increases/decreases the temperature value, while the "B" is used to move to the next temperature. With the "E" key (OK) the set values are confirmed.

SLEEP FUNCTION

The sleep is only activated when the stove supplies power and makes it possible to programme a stove shut off time. The shut off can be delayed for a maximum of 8 hours from current time and with a 10 minute resolution.

To activate, enter the PROGRAM menu, scroll using arrow key "D" up to the Function. SLEEP press the ATTIVA (ACTIVATE) "C" key. In the next screen, using keys "C" and "D", increase or decrease the minutes (10 minutes each time the key is pressed) and press OK ("E" key) to confirm the stove shut off time.

NOTE: If the stove is not supplying power the display shows the wording "NOT AVAILABLE".

Technical Dept. - All rights reserved - Reproduction is prohibited 41

12 - INFORMATION MENU

INFORMATION

To enter the menu INFORMATION proceed as follows: from the main/initial screen, press the "E" Menu button, scroll using the "D" arrow key, up to the Information item, press the "E" ok key, scroll again using the "D" arrow key up to software/data memory/all.memory/stove state and select the desired item, press OK using the

"E" key to enter the chosen information menu.

ON

OFF

MENU

TEMPERATURE

INFORMAZIONI

ESCI

PROGRAMMI

IMPOSTAZIONI

OK

INFORMAZIONI

SOFTWARE MEMORIA DATI

MEMORIA ALL.

STATO STUFA

ESCI OK

E D E D E

10:13 TIMER1 ECO

25°

23° AUTO

OFF TEMP VENT MENU

B C

MAIN SCREEN

The available information is:

• Software

• Data memory

• All. memory

• Stove state

D E

INFORMAZIONI

SOFTWARE

MEMORIA ALL.

ESCI

MEMORIA DATI

STATO STUFA

OK

B C

SOFTWARE INFORMATION

The available data in this function are:

CODE

FIRMWARE

DATABASE

INTERFACE

It is information that can be used to identify the electronic part of the stove.

D E

INFORMAZIONI-SOFTWARE

CODICE = MDUO

FIRMWARE = 140.7.08.08 [07]

BANCA DATI = 000.022

PANNELLO = 14040613A/1000313B

ESCI EXAMPLE

42

12 - INFORMATION MENU

DATA MEMORY-INFORMATION

INFORMAZIONI-MEMORIA DATI

ORE FUNZIONAMENTO = 100

NUMERO ACCENSIONI = 20

DATA COLLAUDO = 15/01/2013

ESCI

The available data in this function are:

WORKING HOURS

TOTAL IGNITIONS

TEST DATE

ALARM MEMORY-INFORMATION

It gives information about the last alarms detected.

INFORMAZIONI-MEMORIA ALL.

ALLARME 02 - 28/06/13 13:44 1

ALLARME 02 - 21/06/13 08:03 2

ALLARME 02 - 21/06/13 08.02 3

ALLARME 02 - 21/06/13 09.46 4

ESCI

Technical Dept. - All rights reserved - Reproduction is prohibited 43

12 - INFORMATION MENU

STOVE STATE-INFORMATION

This menu is particularly useful if one wants to verify the stove work condition (State).

From the OFF screen, press the "E" Menu button, scroll with the "D" arrow key, up to the Information item, press the ok "E" key, scroll again with the "D" arrow key up to stove state, press OK with the "E" key and one enters the stove State-information menu.

The items available within STOVE-STATE INFORMATION can be viewed using the "C" and "D" arrow keys and are:

INFORMAZIONI-STATO STUFA

STATO = 0-OFF

TEMP.ACQUA = -43°C SET = 70°C

ACTIVE+ = 471 SET = 400

VENT.FUMI = 0 SET = 0

ESCI

INFORMAZIONI-STATO STUFA

COCLEA = 0 SET = 0

TEMP.FUMI = 30°C REQ = BOLL

VENT ARIA = 0% POMP. = OFF

VAL.3-VIE = NO HY. CAND. =OFF

ESCI

C

INFORMAZIONI-STATO STUFA

MODBUS COM. = OFF IND.=4

ESCI

C D state water temp.

aux sensor active+ fumes fan auger fumes temp.

air fan relay aux modbus com set set set set set req pump spark plug add.

D

• The main stove states that can be read on the display are:

STATE 1-9 various ignition phases

STATE 20-40 work state (power supply)

STATE 60-79 alarm state

STATE 80-84 shut off/cooling/autoeco state

STATE 85-93 auxiliary functions

STATE 94-95 cleaning state

• WATER TEMP.: Water temperature detected by the probe inside the stove and related SET

• AUX SENSOR: detects the value measured by the aux sensor (external/boiler/puffer)

• ACTIVE+.: Value read by the Active Plus system and related SET

• FAN FUMES: Number of fumes fan revolutions and related SET

• AUGER: Number of auger revolutions and related SET

• FUMES TEMP: fumes temperature value read by the probe inside the stove

• REQ: (Heating/Sanitary) signals if system requires heat

• AIR FAN: Room fan operation level

• PUMP: signals if the stove's internal pump is turned on (ON) or turned off (OFF)

• RELAY AUX: signals activation (ON) or the OFF state of Auxa relay

• SPARK PLUG: Signals if spark plug is turned on or off

• MODBUS COM: External interface communication state

• ADD.: Address for communicating with modbus

44

13 - SETTINGS MENU

SETTINGS

To enter the menu SETTINGS proceed as follows: from the OFF screen , press the "E" Menu key, scroll with the "D" arrow key, up to the Settings item, press the ok "E" key, scroll again with the "D" and/or "C" arrow key up to the chosen setting, press OK with the "E" key to enter the chosen menu.

It is possible to set the listed parameters from this screen. Each parameter has an info key to obtain brief information about the chosen function.

ON

OFF

MENU

TEMPERATURE

INFORMAZIONI

ESCI

PROGRAMMI

IMPOSTAZIONI

OK

IMPOSTAZIONI

AUTOECO

CARICO COCLEA

HYDRO-AIR

RICETTA PLT

RICETTA ARIA

ESCI

CICLO PULIZIA

OK

E D E B C

• SETTINGS

Auto Eco (default activated)

Hydro Air

Auger loading

Pellet recipe

Active +

Cleaning cycle

Language date - time

Aux Input aux output

Room Input

T. on Pump

Pump Pwm

Antifreeze function

Plt sensor (not available)

Modbus com.

Display

Technical menu (accessible by a specialized MCZ technician - password required)

Active +

Fume Analysis F

Calib.Active

Calib.S.fumes

Diagnostics

Parameters

Boll advance

Hour reset

D E

Technical Dept. - All rights reserved - Reproduction is prohibited 45

13 - SETTINGS MENU

AUTOECO (Factory activated)

IMPOSTAZIONI-AUTOECO

DISATTIVA

AUTOECO

ATTIVA

AUTOECO

INFO OK

SE ATTIVI L’AUTOECO, LA STUFA SI

SPEGNERA’ QUANDO NON CI SONO

PIU’ RICHIESTE DI CALORE

ESCI

B C D E B

The Auto eco mode turns the stove off when the heating system does not require heat depending on the menu-settings-input aux configuration.

AUTO ECO ACTIVE

The AutoEco active parameter (factory settings) is shown on the top right on the control panel display in the main screen. If heat is not required, the stove turns off after the set time, switching to Auto Eco (State 84 - it is possible to see Auto eco in the Information Menu, stove state).

NOTE: With the stove off, if set T is less than T room, or other heat request settings are satisfied the stove does not turn on.

1

2

15:28 ECO

22°

18° AUTO

OFF TEMP VENT MENU

1 = no heat request (T room > T set)

2 = T set if set temperature is increased > T room (therefore in this case > 22°C) the stove with start-up after a few seconds due to the heat request.

B C D E

AUTO ECO DEACTIVATED

With the stove on, if Auto eco is deactivated and there are no heat requests (different based on menu-settings-aux input settings) the stove operates at minimum power.

The required condition for restarting is for there to be a heat request for at least 10" consecutively; it is possible to restart if:

• at least 5' have elapsed from when shutdown began

• the TH

2

O in the stove is < T set H

2

O

To modify the function : from the settings menu - using the arrow keys, select the AUTOECO function, press ok (E key) and press D or C key (arrow key) and select:

Activate = to modify the set time from 0 to 30 minutes (factory default 5 minutes)

Deactivate = to deactivate Auto Eco

46

13 - SETTINGS MENU

HYDRO AIR

IMPOSTAZIONI-HYDRO-AIR

HYD-AIR

AUTO

HYD-AIR

ON

HYD-AIR

OFF

INFO OK

ON = MAX POTENZA ALL’AMBIENTE

OFF=MAX POTENZA ALL’IMPIANTO

AUTO=GESTIONE AUTOMATICA

ESCI

B C D E B

The Hydro Air function can be activated/deactivated manually or managed automatically (factory default setting).

In Hydro-Air On mode the internal three-way valve is switched so that the water, before going towards the system, passes through the front radiator, transferring heat to the environment through the fan up to 6 kW (at maximum power with water temperature at 70°C).

In Hydro-Air Off mode the internal three-way valve is switched so that stove water goes directly to the system, without passing through the front radiator. In this case power released to the environment may reach 3 kW.

In Hydro-Air Automatic mode the three-way valve is managed in an intelligent way by the electronic control in order to release maximum power to the room only when there is an actual heat request from the stove probe. If there is no request from the room, the valve is switched as in OFF mode.

To enter the function: from the settings menu - press ok (E key), press the D key (arrow key) and scroll up to Hydro-air, press OK (E key) and activate the HYD-AIR

AUTO / HYD-AIR ON / HYD-AIR OFF function and press ok "E" key to confirm.

AUGER LOADING (only with the stove off)

This function is for filling the pellet loading system. Can only be activated with the stove off.

IMPOSTAZIONI-CARICO COCLEA

DISATTIVA

CARICO

INFO

ATTIVA

CARICO

OK

USA IL “CARICO COCLEA” QUANDO LA

COCLEAE’ RIMASTA VUOTA E LA DEVI

CARICARE VELOCEMENTE

ESCI

B C D E B

To enter the function: from the settings menu - press ok (E key), press the D key (arrow key) and scroll up to load auger, press OK (E key) and activate/deactivate the function, press ok ("E" key) to confirm.

Technical Dept. - All rights reserved - Reproduction is prohibited 47

13 - SETTINGS MENU

PELLET RECIPE

INFO

IMPOSTAZIONI-RICETTA PLT

+15%

OK

VARIA PERCENTUALMENTE LA VELOCITA’

DELLA COCLEA PER ADATTARE LA STUFA

AL TIPO DI PELLET

ESCI

B C D E B

This function is for adapting the stove to the type of pellet in use. As there are many types of pellet available on the market, stove operation can vary considerably according to the quality of the fuel. When the pellets clog up the brazier due to excess loading of fuel, vice-versa if the flame has a tendency to shut-off, it is possible to decrease/increase the amount of pellets in the brazier:

The available values compared to factory settings are:

+15% +10% + 5%; 0%; -10% -20% -30%

To modify the pellet recipe, in sequence, press: from the Settings menu- press ok (E key), press the D KEY (arrow) scroll up to pellet recipe and press OK (E key) and enter the function, using the "C" and "D" keys to modify the parameter and press Ok ("E" key).

ACTIVE +

The pellet type is not a problem because the stoves are equipped with the Active system and automatically adapt to pellet of any length with a diameter of 6-8 mm. Effective and efficient combustion is independent from any type of connection to the flue which, with traditional systems, may constitute a problem during the installation phase.

Thanks to an internal sensor, the stove is extremely reliable and precise. Combustion air is constantly adjusted based on the quantity of pellets present in the brazier, guaranteeing an effective and efficient combustion this way that translates into decreased consumption, emissions and less frequent cleaning.

Thanks to Active plus, it is possible to control and communicate with the stove, even by way of Smartphone and tablet. Since it is possible to manage more evolved gear motors (with continuous operation), and the new pellet stoves equipped with active plus are more silent.

INFO

IMPOSTAZIONI-ASPIRAT.

0%

OK

CORREGGI LA PORTATA

DELL’ARIA COMBURENTE

ESCI

B D E B

This function is used to adjust combustion air if the flame is too high or too low.

It can be activated from the SETTINGS menu, scroll using the “D” arrow key up to the “Ricetta Aria” (Air recipe) function, press OK using the

“E” key, and, using the “D” arrow key modify the parameter and press “ok” “E” key.

The fixed parameters that can be set are: +10; +5; -5; -10

48

13 - SETTINGS MENU

CLEANING

IMPOSTAZIONI-CICLO PULIZIA

DISATTIVA

CICLO PUL.

ATTIVA

CICLO PUL.

INFO OK

ATTIVA SUBITO UN CICLO DI

PULIZIA DEL BRACIERE

ESCI

B C E B

This function can only be activated while the power supply is in the following mode: from the Settings menu- press ok (E key), press the D key (arrow), scroll up to the “ciclo pulizia” (cleaning cycle) press OK (E key)- Activates/ deactivates cleaning.

This procedure activates the fume extraction fan at the maximum level in order to clean the brazier and expel soot.

LANGUAGE

This function is used to choose the desired language among those set in the control panel.

To enter the function, from the Settings menu - press ok (E key), press the D key (arrow key) and scroll up to language item, press OK (E key) and choose the language among the various ones set and finally press Ok ("E" key) to confirm.

The available languages are: Italian/English/French/German/Spanish/Dutch/Danish

IMPOSTAZIONI-LINGUA

ITALIANO

ENGLISH

FRANCAIS

OK

B C D E

DATE-TIME

This function is used to set date and time.

To enter the function, from the Settings menu - press ok (E key), press the D key (arrow key) and scroll up to the date-time item, press OK

(E key) to enter the function. Next, press the "E" (ok) key again to modify day/month/year/hour and minutes. To modify the parameters, use the “C” and “D” (arrow) keys and press the "E" key to confirm.

ESCI

IMPOSTAZIONI-DATA-ORA

OGGI E’ LUNEDI’

24/06/13

E SONO LE

14:14

OK

B C

Technical Dept. - All rights reserved - Reproduction is prohibited

D E

49

13 - SETTINGS MENU

AUX INPUT (using one of the following parameters excludes the other)

The auxiliary input allows choosing the system configuration type based on which the stove is connected.

To enter the function press: from the Settings menu- press ok (E key), press the D (arrow) key and scroll up to the Aux Input item and press OK (E key). Using the “C” and “D” keys select the desired heating system type and press ok with the “E” key.

IMPOSTAZIONI-INGRESSO AUX

TERMOST AMB 2 SONDA ESTERNA

SONDA BOLLIT.

TERMOST BOLL.

SONDA PUFFER

INFO

TERM. PUFFER

OK

B C D E

It is possible to connect the following to the auxiliary input:

Room thermostat 2

External probe

Boiler probe

Boiler thermostat

Puffer probe

Puffer Thermostat

Note: The boiler probe/thermostat choice implies the three-way aux output designation.

The puffer probe/thermostat choice implies the pump aux output designation.

• Room Therm.2

The stove heat request may take place from any part of the room probe or from the “Termostato Amb 2” (Room thermostat 2) installed in a room that is different from the one where the stove is positioned and is connected to terminals 1 and 2 of the back terminal board.

Contact closing the terminal kicks off the heat request.

Notes: Installation of this thermostat is optional, the stove can also operate without it. Since the contact is N.O., the room probe is the only heat request command.

Possible active weekly programming does not act on Room Thermostat 2 but rather on the probe on board the stove.

50

13 - SETTINGS MENU

• External probe

It makes it possible to work with system temperature adjustment. If installing an external probe on terminals 1 and 2 (NTC 10KOhm at

25°C b=3435) water temperature is automatically calculated by the electronics based on the external temperature according to the curves shown below.

The external probe must be installed on an external wall exposed towards North or North-West. If necessary, it is possible to correct the value read by the probe of + 5 -5°C.

• Boiler probe

To activate this option, connect a probe (NTC 10KOhm at 25°C b=3435) to points 1 and 2 of the back 9 pole terminal board.

The heat request occurs when the boiler probe reads a temperature that is 2°C below the one set by the accumulation temperature marked by a tap in the temperature menu.

In this configuration the aux output is configured as a potential free contact to control the 3-way valve (contact 7-8-9 of the back 9 pole terminal board)

• Boiler thermostat

To activate this option, connect a Normally Open (N.O.) contact thermostat to points 1 and 2 of the back 9 pole terminal board.

The heat request occurs when boiler thermostat closes the contact.

Even with this configuration the Aux output is configured as a potential free contact to control the 3-way valve (contact 7-8-9 of the back

9 pole terminal board).

• Puffer probe

To activate this option, connect a probe (NTC 10KOhm at 25°C b=3435) to points 1 and 2 of the back 9 pole terminal board.

The heat request occurs when the boiler probe reads a temperature that is 2°C below the one set by the accumulation temperature marked by a radiator in the temperature menu.

During the installation with puffer, stove operation is only and exclusively determined by the puffer probe and not by the room probe. The purpose of the room probe on the stove is only to control the heating system pump controlled by the potential free contact N.O.: (max 5 ampere, not suitable for brushless pumps with upper start-up current) on terminals 8-9.

Example of operation with Hydro Air On or Auto:

• if the puffer is satisfied but the room probe is not, with eco stop active the stove shuts off (continuing to disburse heat through the room fan up until shut-off)

• if the puffer is satisfied but the room probe is not, with eco stop deactivated, the stove remains on at minimum power. In this case hot water from the puffer is used through the pump to heat the front radiator

• if the puffer calls for heat and the room probe does not, the fan behaves based on “Hydro Air” and “Ventilatore” (Fan) settings.

Technical Dept. - All rights reserved - Reproduction is prohibited 51

13 - SETTINGS MENU

• Puffer thermostat

To activate this option, connect a Normally Open (N.O.) contact thermostat to points 1 and 2 of the back 9 pole terminal board.

Even with this configuration the purpose of the room probe on the stove is only to control the heating system pump controlled by the potential free contact on terminals 7-8-9.

POS.1-2 EXTERNAL THERMOSTAT/THERMOSTAT/BOILER/PUFFER

(AUX INPUT) BOILER PROBE/PUFFER

POS.3-4 ROOM PROBE (ROOM INPUT)

POS.5-6 HOME AUTOMATION

POS.7-8-9 AUX OUTPUT RELAY

INPUT AUX

1 2 3 4 5 6

NC NO C

7 8 9

52

13 - SETTINGS MENU

HYDRO AIR STOVE PRINCIPLE DIAGRAMS

The following diagrams are to be used only as a guideline. For proper connection, always follow the notes for the plumbing and heating installer. The plumbing system must meet local, regional or national requirements.

Installation and verification of operation is to be performed only by specialized, authorized personnel. The manufacturer will not be held liable for noncompliance with the provisions listed above.

HEATING ONLY CONFIGURATION

BOILER CONFIGURATION

POS.1-2 = BOILER

PROBE/THERMOSTAT

NC NO C

7 8 9

Technical Dept. - All rights reserved - Reproduction is prohibited 53

13 - SETTINGS MENU

HYDRO STOVE WITH PUFFER CONFIGURATION

POS.1-2 = PUFFER PROBE/

THERMOSTAT

1 2 3 4 5 6

NC NO C

7 8 9

54

13 - SETTINGS MENU

OUTPUT AUX

IMPOSTAZIONI-USCITA AUX

ALLARME

REMOTO

CALDAIA

AUX

USCITA

IN TEMP

INFO OK

IMPOSTA L’INGRESSO AMBIENTE:

SONDA O TERMOSTATO.

MORSETTI 3-4

ESCI

B C D E B

The AUX output makes it possible to use a relay contact, based on the system configuration type chosen in the Aux Input menu.

It acts on contact 7-8-9 of the external terminal board. The functions can only be selected if boiler or puffer configuration has not been chosen in the Aux Input menu and are:

• Remote alarm (9-8=C-NO)

• Auxiliary boiler (9-7=C-NC)

• Auxiliary output in temperature (9-8-7=C-NO-NC)

To enter the function press: from the Settings menu- press ok (E key), press the D (arrow) key and scroll up to the Aux Output item and press OK (E key). Using the “C” and “D” keys to select the Remote Alarm(Aux boiler/Output in temp and press OK ("E" key).

• If the Aux output is set on Remote Alarm, the NO contact is closed when an alarm is present.

• If the Aux output is set to Auxiliary Boiler, the NC contact remains closed in all alarm states, in = "OFF" state, in 80 “Shutdown” state and in 51 “COOL” state. Under all conditions it remains open.

• Output at temperature: the NO contact closes when Boiler temperature exceeds the value set by the user. It can be set from 30 to 60, it is used, for example, to disconnect the aux boiler above a certain temperature (using the NC contact) or to start an external pump at temperature (using the NO contact)

• If the boiler configuration has been chosen, the Aux contact is fixed at “Valvola tre vie bollitore” (Three-way boiler valve): the contact switches when a heat request is received from the boiler.

• If the Puffer configuration has been chosen, the Aux contact is fixed at “Comando pompa” (Pump Control): the NO contact closes when a heat request is received from the Room PROBE

Technical Dept. - All rights reserved - Reproduction is prohibited 55

13 - SETTINGS MENU

ROOM INPUT

IMPOSTAZIONI-INGRESSO AMB

SONDA

AMBIENTE

TERMOSTATO

AMBIENTE

INFO OK

IMPOSTA L’INGRESSO AMBIENTE:

COME SONDA O COME TERMOSTATO.

(MORSETTI 3-4)

ESCI

B C D E B

The room input is used to set the probe or the thermostat at terminals 3-4 of the back terminal board of the stove.

The stove has the room probe set as default factory settings.

Selecting the thermostat it is possible to replace the probe on the stove with a thermostat that requests heat when the contact is closed.

To enter the function press: from the settings menu - press ok (E key), press the D key (arrow) and scroll up to Room Input, press OK (E key) and select room thermostat, press E key to confirm.

Attention!!! If room temperature is selected, weekly hourly programming is not available.

PUMP ON T

This function enables adjustment of the pump activation temperature.

To enter the function press:

INFO

IMPOSTAZIONI-T ON POMPA

60°

OK

TEMPERATURA MINIMA DELL’ACQUA

PER LA PARTENZA DELLA POMPA

DI CALDAIA

ESCI

B C D E B from the Settings menu- press ok (E key), press the C-D key (arrow) and scroll up to temp.On pump, press OK (E key)- Modify the temperature using the central C and D keys, press the E key to confirm.

56

13 - SETTINGS MENU

PWM PUMP

This function is used to set high efficiency pump speed.

To enter the function press: from the Settings menu- press ok (E key), press the C-D key (arrow) and scroll up to PWM Pump, press OK (E key)- Modify the percentage using the central C and D keys, press the E key to confirm.

INFO

IMPOSTAZIONI-POMPA PWM

AUTO

OK

IMPOSTA LA VELOCITA’

DELLA POMPA PWM AD

ALTA EFFICIENZA

ESCI

B C D E B

FUNCT. ANTI-FREEZE

It consists of activating the pump (level 1) or the stove (level 2) and is automatically activated by the temperature read by the stove probe and the temperature read by the external probe (if present and connected to the aux input).

IMPOSTAZIONI-FUNZ ANTIGELO

DISATTIVA

FUNZ ANTI.

ATTIVA

FUNZ ANTI.

INFO OK

IMPOSTA LA TEMPERATURA

DI ATTIVAZIONE DELLA FUNZIONE

ANTIGELO

ESCI

B C D E

The level 1 anti-freeze activation conditions (PUMP ON) are: boiler temp < anti-freeze set +3°C

The level 2 anti-freeze activation conditions (PUMP and FLAME ON) are: boiler temp = anti-freeze set

Anti-freeze activation conditions on external probe (if present) are: ext_filtered temp < anti-freeze set -3℃

B

To enter the function, press and adjust anti-freeze set: from the Settings menu- press ok (E key), press the C-D key (arrow) and scroll up to Antifreeze function and press OK (E key)- Activate and set (from 1 to 5°C) or deactivate the function and press the E key to confirm.

PELLET SENSOR

Optional Function.

Technical Dept. - All rights reserved - Reproduction is prohibited 57

13 - SETTINGS MENU

MODBUS COM.

Is a communication system that makes it possible for the stove to receive commands from a Smartphone/tablet through a Web/Wi-fi interface.

To enter the function press: from the settings menu - press ok (E key), press the C-D key (arrow) and scroll up to Modbus com. and press OK (E key)- Set the address and press E key to confirm.

IMPOSTAZIONI-MODBUS COM.

INDIRIZZO

3

INFO OK

IMPOSTA L’INDIRIZZO MODBUS SLAVE

BAUD RATE 19.200 1 STOP BIT -

EVEN PARITY - 19200 8N1

ESCI

D E B

DISPLAY

B C

IMPOSTAZIONI-DISPLAY

CONTRASTO

LUMINOSITA’

OK

B C D E

Adjust display contrast and brightness. This function is found in: from the Settings menu- press ok (E key), press the C-D key (arrow) and scroll up to Display, press OK (E key)- Modify the settings using the B - C - D keys and press the E key to confirm.

58

14 - TECHNICAL MENU

TECHNICAL MENU

To access the technical menu you must contact the assistance centre as it requires a password.

To make changes in the technical menu, enter the SETTINGS menu, press the "E" (OK) key, scroll using the “C”-”D” arrows and select

Technical menu and press OK (E key)- Enter the password and press the E key to confirm.

ESCI

IMPOSTAZIONI-MENU TECNICO

DIGITA PASSWORD

0000

OK

B C D E

To enter the password: using the C and D keys, set the numbers (1-2-3....9) with the E (OK) key and move on to the next digit, once the four digits have been entered, press the E key to enter the technical menu.

The technical menu displays the following parameters:

• ACTIVE +

• FUMES ANALYSIS F.

• CALIB.ACTIVE

• CALIB.S.FUMES

• DIAGNOSTIC

• PARAMETERS

• BOLL ADVANCE

• RESET HOURS

Technical Dept. - All rights reserved - Reproduction is prohibited 59

15 - SAFETY DEVICES AND ALARMS

SAFETY DEVICES

The product is fitted with the following safety devices

ACTIVE +

Besides adjusting the stove operation, it also guarantees that the pellet loading auger is blocked if unloading or there is significant back pressure.

SMOKE TEMPERATURE PROBE

Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the preset value.

CONTACT THERMOSTAT IN THE FUEL HOPPER

If the temperature exceeds the preset safety level, it immediately shuts down the running of the stove.

WATER THERMOSTAT

If the temperature exceeds the preset safety level, it immediately shuts down the running of the stove.

WATER TEMPERATURE SENSOR

When the water reaches the stop temperature (85°C) the probe automatically instructs the boiler to carry out automatic "OFF Stand-by" shut-off.

ELECTRICAL SAFETY

The stove is protected against violent changes in current by a general fuse located in the control panel at the back of the stove. Other fuses that protect the circuit boards are located on the latter.

SMOKE FAN

If the fan stops, the electronic board shuts off the supply of pellets in good time, and an alarm message is displayed.

GEAR MOTOR

If the reduction motor stops, the stove will continue to run until the flame goes out due to lack of fuel and until a minimum level of cooling is reached.

TEMPORARY POWER CUT

When a power cut is less than 10" the stove returns to its previous operating state; if it is more, it executes a cooling/re-ignition cycle.

FAILED START-UP

If during ignition no flame develops, the stove will go into alarm condition.

ANTI-FREEZE FUNCTION

If the probe in the boiler detects a water temperature of less than 5°C, the circulation pump is automatically activated to keep the system from freezing.

PUMP ANTI-SEIZURE FUNCTION

If the pump is not used for prolonged periods, it is activated periodically for a few seconds to keep it from seizing up.

60

15 - SAFETY DEVICES AND ALARMS

TAMPERING WITH THE SAFETY DEVICES IS PROHIBITED

If the stove is NOT used as described in this instruction booklet, the manufacturer refuses to accept any responsibility for damage to persons and property that may arise. The manufacturer furthermore refuses to accept responsibility for damage to persons and property arising from the failure to observe all the rules contained in the manual and in particular:

• All the necessary measures and/or precautions must be adopted when performing maintenance, cleaning and repairs.

• Do not tamper with the safety devices.

• Do not remove the safety devices.

• Connect the stove to an efficient smoke extraction system.

• First, check that the environment where it is to be installed is properly ventilated.

Only after eliminating the cause of the intervention of the safety system is it possible to re-ignite the stove and thus restore its automatic operation. This manual will help you understand which anomaly has occurred, and explain how to intervene according to the alarm message displayed on the stove.

Technical Dept. - All rights reserved - Reproduction is prohibited 61

15 - SAFETY DEVICES AND ALARMS

ALARM ALERTS

If there is an operational anomaly, the stove enters the alarm phase displaying the problem that has taken place through a code, a brief description of the alarm type and an acoustic warning.

The following table describes the possible alarms indicated by the stove, associated to the respective code that appears on the panel and helpful tips to solve the problem.

B = RESET (cancels alarm)

C = INFO (provides information on the alarm type)

E = MENU

RESET

A05

OSTRUZIONE CANNA

FUMARIA

INFO MENU

B C E

62

WRITTEN ON THE

DISPLAY

A01

NO IGNITION

A02

NO FLAME

TYPE OF PROBLEM

The fire does not ignite.

(without acoustic alarm)

The fire goes out abnormally.

(without acoustic alarm)

A03

PLT SAFETY

Pellet tank temperature is too high

A04

FUME TEMP

A05

OBSTRUCTION

Fume temperature is too high

Chimney flue clogged

SOLUTION

Check the level of pellets in the tank.

Check that the brazier rests correctly in its seat and has no visible deposits of unburned pellets.

Check the level of pellets in the tank.

Check that the brazier rests correctly in its seat and has no visible deposits of unburned pellets.

Wait for the cooling phase to end, cancel the alarm and reduce pellet loading (SETTINGS MENU - Pellet recipe). If the alarm persists, contact the service centre.

Wait for the cooling phase to end, cancel the alarm and reduce pellet loading (SETTINGS MENU - Pellet recipe). If the alarm persists, contact the service centre.

Verify brazier clogging, smoke duct, lower compartment and door closing. If the alarm persists, contact the service centre.

15 - SAFETY DEVICES AND ALARMS

WRITTEN ON THE

DISPLAY

A08

FLUE GAS FAN

A13

BOARD TEMP

A14

ACTIVE SENSOR

A18

WATER SIC

A19

WATER PROBE

A20

AUX PROBE

TYPE OF PROBLEM

Faulty smoke fan.

A09

SMOKE TEMPERA-

TURE PROBE

A11

GEAR REDUCER

Smoke sensor fault.

Auger gear reducer fault.

Electronic board overheating

Active sensor anomaly

Water thermostat intervention

Fault with water sensor

Auxiliary probe fault

SOLUTION

Check that the lower compartment is clean (see dedicated stove cleaning pages) and verify that it is not obstructed, is clean and cancel the alarm.

If the alarm persists, contact the service centre.

Contact an authorised service centre to have the component replaced and, if needed, replace the component.

The component is not working regularly.

Contact an authorised service centre to have the component replaced and, if needed, replace the component.

Wait for the cooling phase to end, cancel the alarm and reduce pellet loading (SETTINGS MENU - Pellet recipe). If the alarm persists, contact the service centre. .

Active Plus sensor operation anomaly. Contact an authorised service centre to have the component replaced and, if needed, replace the component.

Water temperature is too high or thermostat operational anomaly. If the alarm persists, contact the service centre.

Possible fault in the safety component. Contact an authorised service centre to have the component replaced and, if needed, replace the component.

Possible component fault.

Check that the probe inserted in the system respects the characteristics specified in the instructions (see external probe).

Contact an authorised service centre to have the component replaced and, if needed, replace the component.

Exiting the alarm conditions

When the stove enters an alarm state, an automatic cooling/shut-off phase begins, at the end of which the cause of the alarm is displayed on the small panel.

Before resetting the alarm, follow the controls indicated in the previous table, and then press the RESET key for a few seconds (or remove power to the stove using the main ON/OFF switch on the back of the stove).

If the indicated actions do not resolve the problem, the alarm condition will occur once again with different timing based on the alarm type: in this case, contact technical assistance.

Technical Dept. - All rights reserved - Reproduction is prohibited 63

15 - SAFETY DEVICES AND ALARMS

SHUT DOWN

If the shut down key is pressed or one of the following conditions occurs:

• power request ends (Power = 0) for Ecostop, Timer, Sleep

• an alarm condition occurs

• water overheating occurs the stove enters the shut down and thermal cooling phase that includes automatically executing the following phases:

• pellet loading stops

• the room fan maintains the set speed until it cools down

• the fumes extractor is activated at maximum speed and remains on for a fixed period of 5 minutes, at the end of which the stove off temperature is reached.

During the shut down phase the small panel displays the wording OFF (see screen) but if it is in shut down due to an alarm condition, the small panel displays the related code (See alarms table)

ON

OFF

ECO

MENU

B E

BLACKOUT WITH STOVE ON

If power is lost for less than 10" from stove start-up, it is repositioned in the phase where it was before the power failure.

If the loss of power exceeds 10", when the stove is powered once again, it goes back to the previous operational condition with the following procedure it

• carries out a cooling phase, during which the panel displays OFF BLACKOUT

• restarts the stove

If the stove is in ignition phase when the blackout occurs, it will not turn back on once the power is restored (there is a risk that residual pellets are present in the brazier) and the panel will display OFF BLACK-OUT.

If the ON key is pressed during the cooling phase, the stove stops executing the blackout restore state and it proceeds with ignition as requested by the command. In the same way, pressing OFF is interpreted as a shut off command.

64

16 - CLEANING AND MAINTENANCE

EXAMPLE OF A CLEAN BRAZIER EXAMPLE OF A DIRTY BRAZIER

ATTENTION!

All the cleaning operations of all parts must be performed with the product completely cold and the plug disconnected.

The product requires little maintenance if used with certified good quality pellets.

DAILY OR WEEKLY CLEANING PERFORMED BY THE USER

BEFORE EACH IGNITION

Clean the ash and any deposits in the brazier that could clog the air passage holes. If the pellets in the hopper run out, unburned pellets may accumulate in the brazier. Always empty the residue in the brazier before each start-up.

REMEMBER THAT ONLY A CORRECTLY POSITIONED AND CLEAN GRATE CAN GUARANTEE THE OPTIMAL LIGHTING AND

OPERATION OF YOUR PELLET STOVE.

For the brazier to be cleaned properly, remove it from its housing completely and thoroughly clean all the holes and the grate on the bottom.

If good quality pellets are used, you will normally only need to use a brush to restore the optimal operating conditions of the component.

CHECKS TO BE PERFORMED EVERY 2/3 DAYS

Clean compartment around brazier to remove any ash, being careful of hot ash.

Only if the ash is completely cold, is it possible to use a vacuum cleaner to remove it. In this case, use a suitable vacuum cleaner to remove particles of a certain size. The quality of the pellets used and user experience will determine the required cleaning frequency.

However, it is recommended not to exceed 2 or 3 days.

CLEANING THE GLASS

It is recommended to clean the ceramic glass with a dry brush, or if it is very dirty, spray a little specific detergent and clean with a cloth.

ATTENTION!

Do not use abrasive products and do not spray the glass cleaning product on the painted parts and on the door gaskets (ceramic fibre cord).

Technical Dept. - All rights reserved - Reproduction is prohibited 65

16 - CLEANING AND MAINTENANCE

CLEAN THE EXCHANGER AND THE COMPARTMENT BENEATH THE BRAZIER EVERY 2/3 DAYS

Cleaning the exchanger and the compartment beneath the brazier is a simple operation but very important if the boiler is to maintain optimal performance.

We therefore recommend cleaning the internal exchanger every 2-3 days, performing these simple operations in sequence:

• Activate the “PULIZIA” (CLEANING) function – with the stove on press - menu (“E” key), select “IMPOSTAZIONI” (SETTINGS) using the “C” and “D” key and press OK (“E” key), scroll using the “C” and “D” keys and select “CICLO PULIZIA” (CLEANING CYCLE), confirm pressing “OK” (“E” key), activate the “ATTIVA CICLO DI PULIZIA” (ACTIVATE CLEANING CYCLE) function, confirm by pressing OK (“E” key).

This procedure starts the smoke extractor on the maximum setting to expel the soot that becomes dislodged when the exchanger is cleaned.

• Clean the pipe unit - Using the provided hook ”A”, shake the rods located beneath the top firmly 5-6 times. This will remove any soot that has deposited on the exchanger's smoke ducts during normal stove operation.

• Deactivate the “CICLO PULIZIA” (CLEANING CYCLE) function – this function is deactivated by pressing the “DISATTIVA CICLO

PULIZIA” (DEACTIVATE CLEANING CYCLE).

• Clean the smoke conveyor compartment (fig. in following page) - The stove is equipped with a removable ash tray “ G ” which collects any accumulations of soot and ash.

• Once cleaning is finished reposition the top and the ash tray“ G ”.

If such cleaning is not done every 2-3 days the stove could go into alarm caused by ash clogging after several hours of operation.

A A

TEMPERATURE

INFORMAZIONI

ESCI

PROGRAMMI

IMPOSTAZIONI

OK

B C D

IMPOSTAZIONI

AUTOECO

CARICO COCLEA

RICETTA ARIA

HYDRO-AIR

RICETTA PLT

CICLO PULIZIA

ESCI OK

E

B C D E

66

16 - CLEANING AND MAINTENANCE

CLEANING THE LOWER COMPARTMENT

Clean around the brazier “ C ”. Remove the tray “ D ” and the brazier “ C ”. Loosen the screws and remove the fumes plug “ E ” and using the nozzle of a vacuum cleaner, remove any ash and soot that may have built up in the lower exchanger indicated by the arrow.

Before putting the cap “ E ” back, changing gasket “ F ” is recommended

Before removing ash using a vacuum cleaner, it is recommended to clean the internal walls of the stove using the supplied scraper.

SCRAPER

B

G

F

E

D

C

Technical Dept. - All rights reserved - Reproduction is prohibited

LOWER COMPARTMENT

CLEANING

67

16 - CLEANING AND MAINTENANCE

PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN

CLEANING THE EXCHANGER AND PIPE UNIT

In order to clean the exchanger and the pipe unit, while the stove is cold, proceed in the following manner:

1

2

3

2

1

8

5

12

11

15

16 14

13

17

8

7

6

8

11

12

18

5

8

9

3

14

15

16

4

1

10

1

68

16 - CLEANING AND MAINTENANCE

• Remove the top “ 1 ”

• Remove the 4 screws “ 2 ”

• Remove the two profile supports “ 3 ”

To avoid removing the entire cladding, block the two front profiles with two clamps “ 4 ”.

• Remove the four screws “ 5 ” and as a result remove the two plates of the turbulator rods “ 6 ”

• Loosen the two screws “ 7 ”, remove the two screws “ 8 ” and remove the entire fan block “ 9 ”

• Remove the exchanger “ 10 ”

• Loosen the two screws “ 11 ”, remove the two screws “ 12 ” and remove the exchanger support “ 13 ”

• Loosen the two screws “ 14 ” and remove the rods “ 15 ”

• Remove the two screws with shims “ 16 ” and the stove cover “ 17 ”

• Remove the turbulators “ 18 ”

At this point, using a rod or a brush for cleaning bottles, clean inside the pipe unit and the pipes, removing any ash deposits.

Check the cover seal “ 17 ” and replace it if necessary.

CAUTION: the exchanger must be cleaned at the end of the season by an authorised and qualified technician so that any worn seals may be replaced.

CLEANING THE SMOKE DUCT AND GENERAL CHECKS

Clean the smoke extractor duct, especially around the “T” joints, bends and any horizontal sections.

For information on cleaning the flue, contact a chimney sweep.

Check the seal of the ceramic fibre gaskets on the door of the stove. If necessary, order new replacement gaskets from the retailer or contact an authorised service centre to carry out the operation.

CAUTION:

The frequency with which the smoke outlet system is cleaned depends on the use of the boiler and the type of installation.

We recommend relying on an authorised service centre for end-of-season cleaning and maintenance, as they will carry out all of the previously mentioned work and inspect the stove components.

SHUTDOWN (end of season)

At the end of each season, before switching the product off, it is recommended to remove all the pellets from the hopper with a vacuum cleaner with a long pipe.

When not in use the appliance must be disconnected from the mains power supply. It is recommended to remove the power cable for additional safety, especially in the presence of children.

The service fuse may have to be replaced if the control panel display does not switch on when the product is switched on again by pressing the main switch on its side.

There is a fuse compartment on the back of the product, under the power socket. After having disconnected the plug from the socket, use a screwdriver to open the cover of the fuse compartment and if necessary, replace them (3.15 A delayed).

Technical Dept. - All rights reserved - Reproduction is prohibited 69

16 - CLEANING AND MAINTENANCE

CHECKING THE INTERNAL COMPONENTS

ATTENTION!

The internal electromechanical components must only be checked by qualified personnel whose technical expertise includes combustion and electricity.

We recommend that an annual maintenance service is carried out (with a scheduled service contract). This service is essentially a visual and functional inspection of the internal components. The following is a summary of the checks and/or maintenance that are essential for the correct operation of the product.

PARTS/INTERVAL

Brazier

Ash pan

Glass

Lower compartment

Complete exchanger

Smoke duct

Door gasket

Internal parts

Flue

Circulation pump

A plate heat exchanger

Plumbing components

Electro-mechanical components

1 DAY

·

2-3 DAYS

·

7 DAYS

·

·

30 DAYS 60-90 DAYS

·

·

·

1 YEAR

·

·

·

·

·

·

CLEANING THE CONTROL PANEL DISPLAY

ATTENTION!!

THE PANEL DISPLAY IS VERY DELICATE, IT IS SUPPLIED WITH A PROTECTIVE FILM.

RECOMMENDATIONS FOR CLEANING:

Clean using a soft cotton cloth, dry or slightly moist.

Do not use aggressive detergents or polyester materials.

Do not use abrasive sponges or powder detergents nor solvents such as alcohol and petrol, since they may damage the surface of the device.

70

17-FAULTS/CAUSES/SOLUTIONS

CAUTION:

All repairs must be carried out exclusively by a specialised technician, with the stove completely cold and the electric plug pulled out.

ANOMALY

The pellets are not fed into the combustion chamber.

POSSIBLE CAUSES

The pellet hopper is empty

Sawdust has blocked the feed screw

SOLUTIONS

Fill the hopper with pellets

Faulty gear motor

Faulty electronic board

The fire goes out or the stove stops automatically

The pellet hopper is empty

The pellets are not fed

Empty the hopper and remove the sawdust from the feed screw by hand

Replace the gear motor

Replace the circuit board

Fill the hopper with pellets

See the previous anomaly

The pellet temperature safety probe has been triggered

Let the stove cool down, reset the thermostat until the problem is resolved and switch the stove back on.

If the problem persists contact Technical

Assistance.

Chrono active Check if the chrono setting is active

The door is not closed properly or the gaskets are worn

Close the door and replace the gaskets with original ones

Unsuitable pellets

Low pellet supply

The combustion chamber is dirty

Clogged outlet

Faulty smoke extraction motor

Water tank temperature too high

Change the type of pellets with those recommended by the manufacturer

Check the flow of fuel following the instructions in the booklet.

Clean the combustion chamber, following instructions in the manual

Clean the smoke duct

Check the motor and replace it, if necessary

Check correct operation of the water circulation pump and the hydraulic system in general.

Technical Dept. - All rights reserved - Reproduction is prohibited 71

17-FAULTS/CAUSES/SOLUTIONS

ANOMALY

The stove runs for a few minutes and then goes out

POSSIBLE CAUSES

Start-up phase is not completed

Temporary power cut

Clogged smoke duct

SOLUTIONS

Repeat start-up

Wait for the automatic restart

Clean the smoke duct

Faulty or malfunctioning temperature probes

Check and replace the probes

Pellets accumulate in the brazier, the glass of the door gets dirty and the flame is weak

Insufficient combustion air

The smoke evacuation motor does not work

Damp or unsuitable pellets

Faulty smoke evacuation motor

No electrical supply to the stove

Motor block caused by clogging.

The motor is faulty

Defective motherboard

Make sure that the air inlet in the room is fitted and clear. Check that the combustion air filter on the Ø 5 cm air inlet pipe is not clogged. Clean the brazier and check that all the holes are clear. Perform a general cleaning of the combustion chamber and the smoke duct. Check the condition of the door gaskets

Change the type of pellets

Check the motor and replace it, if necessary

Check the mains voltage and the protection fuse

Perform a general cleaning of the combustion chamber and the smoke duct.

Check the motor and capacitor and replace them, if necessary

Replace the electronic board

Control panel broken Replace the control panel

The stove does not run No power supply

Pellet or water probe fault

Blown fuse

Faulty spark plug

Check that the plug is inserted and the main switch is in the “I” position

Wait for the pellet or water tank to cool down and restart the stove

Replace the fuse

Check the spark plug and replace it, if necessary

72

17-FAULTS/CAUSES/SOLUTIONS

ANOMALIES RELATED TO THE HYDRAULIC CIRCUIT

ANOMALY POSSIBLE CAUSES

No increase in temperature with stove in operation

Incorrect combustion adjustment

Boiler / system dirty.

Condensation in boiler

Radiators cold in winter

Hot water is not provided

SOLUTIONS

Check recipe

Check and clean the boiler

Insufficient stove power

Poor pellet quality

Incorrect boiler or pump temperature setting

Insufficient fuel consumption

Room thermostat (local or remote) set too low. If remote thermostat, check if it is defective.

Circulator does not run because it is blocked

Check that the stove is properly sized for the requirements of the system

Use pellets from the producer

Set the stove or the pump to a higher temperature

Check recipe

Set to higher temperature or replace. (if remote)

Circulator does not run

Radiators have air in them

Free up the circulator by removing the plug and turning the shaft with a screwdriver

Check the electrical connections of the circulator; replace if necessary

Vent the radiators

Circulator (pump) blocked Free the circulator (pump)

If the stove is NOT used as described in this instruction booklet, the manufacturer refuses to accept any responsibility for damage to persons and property that may arise. The manufacturer furthermore refuses to accept responsibility for damage to persons and property arising from the failure to observe all the rules contained in the manual and in particular:

• The operations in italics must be carried out by specialised personnel from the manufacturer

• All the necessary measures and/or precautions must be adopted when performing maintenance, cleaning and repairs.

• Do not tamper with the safety devices.

• Do not remove the safety devices.

• Connect the stove to an efficient smoke extraction system.

• First, check that the environment where it is to be installed is properly ventilated.

Technical Dept. - All rights reserved - Reproduction is prohibited 73

18-CIRCUIT BOARD

1

2

3

4

6

8

10

9

5

7

11

12 13 14 15 16

MOTHERBOARD WIRING KEY

1. AUX RELAY (C-NO-NC)

2. HOME AUTOMATION CONTACT

3. ROOM PROBE

4. INPUT AUX

5. SMOKE FAN ENCODER

6. GEAR MOTOR ENCODER

7. PRESSURE TRANSDUCER

8. WATER PROBE

9. SMOKE TEMPERATURE PROBE

10. PELLET LEVEL SENSOR (OPTIONAL)

11. AIR FAN PROBE

12. SOFTWARE UPDATE

13. EXPANSION

14. SERIAL COMMUNICATION

15. PWM PUMP CONTROL

16. CONTROL PANEL

17. WATER TEMPERATURE OVERLOAD CUT-OUT

18. HOPPER OVERLOAD CUT-OUT

19. AIR FAN

20. 3-WAY VALVE

21. PWM PUMP SUPPLY

21bis. STANDARD PUMP

22. GEAR MOTOR

23. SMOKE FAN

24. SPARK PLUG

25. SWITCH

N.B. The wiring of the individual components is fitted with pre-wired connectors of different sizes.

74

25

24

22

21

20

23

19

21 bis

18

17

8901306300 REV 0

Via La Croce n°8

33074 Vigonovo di Fontanafredda (PN) – ITALY

Telephone: +39 0434/599599 r.a.

Fax: 0434/599598

Internet: www.mcz.it

www.mcz.it e-mail: [email protected]

12/09/13

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals