Site & Area

PureForm

LED bollard

Gardco PureForm LED bollard PBL integrates a sleek, low profile design, extraordinary light output, and energy savings into an innovative pedestrian scale luminaire. PureForm bollard features a high performance optical system designed to achieve wide spacings and full cutoff performance. Three heights available for a customized look. IP66 optics ensure dust or moisture will never interfere with performance.

Project:

Location:

Cat.No:

Type:

Lamps:

Notes:

Qty:

Ordering guide

Shaft Height Prefix

PBL

PBL PureForm bollard

Number of LEDs Drive Current LED Color - Generation example: PBL-42-14L-450-NW-G2-5-UNV

Distribution

36 Standard Shaft 36"

42 Standard Shaft 42"

60 Standard Shaft 60"

14L 14 LEDs (full ring) 100

200

350

450

100 mA

200 mA

350 mA

450 mA

600

800

600 mA

800 mA

1050 1050mA

WW-G2 Warm White 3000K,

70 CRI Generation 2

NW-G2 Neutral White

4000K, 70 CRI

Generation 2

CW-G2 Cool White 5000K,

70 CRI Generation 2 1

Type 3

3 Type 3

Type 5

5 Type 5

Emergency Voltage

Leave blank for no battery

EBP Emergency battery 2,8,11

120 120V

208 208V

240 240V

277 277V

347 347V

480 480V

UNV 120-277V

(50/60Hz)

Options

Dimming controls Motion sensing Photo-sensing Electrical Finish

DD 0-10V External dimming (by others)

FAWS Field Adjustable 4,5

4,5

SW

LLC

BL

Interface module for SiteWise 3,4,5,6

Wireless controls without PIR sensor 4,5,6

Bi-level functionary with motion sensor 4,12

IMRI

DynaDimmer: Automatic Profile Dimming 4,5

CS50 Security 50% Dimming, 7 hours

CM50 Median 50% Dimming, 8 hours

CS30 Security 30% Dimming, 7 hours

CM30 Median 30% Dimming, 8 hours

Integral infrared 7,12 PCB Photocontrol

Button 9,13

1. Extended lead times apply. Contact factory for details.

2. Not available in 100, 200 or 350mA.

3. Available in 120V or 277V only.

4. Not available with other control options.

5. Not available with motion sensor.

6. Not available with photocontrol.

7. Available only with BL dimming control.

8. Not available with SW, LLC, and CS/CM.

9. Must specify input voltage.

10. Available in 120V only.

Fusing

F1 Single (120, 277, 347VAC) 9

F2 Double (208, 240, 480VAC) 9

F3 Canadian Double Pull

(208, 240, 480VAC) 9

Surge Protection

SP2

GFCI

(10kA standard)

Increased 20kA

Ground Fault Interrupt

Outlet 10

Textured

BK Black

WH White

BZ Bronze

DGY Dark Gray

MGY Medium Gray

Customer specified

RAL Specify optional color or RAL (ex: RAL7024)

CC Custom color

(Must supply color chip for required factory quote)

11.

Not available in 347 or 480V.

12.

Not available in 100, 200, and 1050mA.

13.

Not available with SW or LLC.

PBL_PureForm_bollard 05/20 page 1 of 5

PBL PureForm LED bollard

Site & Area

LED Wattage and Lumen Values

Ordering Code

PBL-14L-100-NW-G2-xx

PBL-14L-200-NW-G2-xx

PBL-14L-350-NW-G2-xx

PBL-14L-450-NW-G2-xx

PBL-14L-600-NW-G2-xx

PBL-14L-800-NW-G2-xx

PBL-14L-1050-NW-G2-xx

14

14

14

14

14

14

LED

Qty

14

LED

Current

(mA)

100

Color

Temp.

4000

200

350

450

600

4000

4000

4000

4000

800 4000

1050 4000

Average

System

Watts

6.1

10.6

17.7

23.1

30.3

40.5

53.8

Type 3

Lumen

Output

BUG

Rating

492 B0-U0-G0

965 B0-U0-G0

1608 B0-U0-G0

2007 B0-U0-G1

2551 B1-U0-G1

3198 B1-U0-G1

3853 B1-U0-G1

Efficacy

(LPW)

81

91

91

87

84

79

72

Lumen

Output

538

Type 5

BUG

Rating

B1-U0-G0

Efficacy

(LPW)

88

1055 B1-U0-G0 100

1758 B1-U0-G0 99

2195 B2-U0-G1

2789 B2-U0-G1

3497 B2-U0-G1

4213 B3-U0-G1

95

92

86

78

Values from photometric tests performed in accordance with IESNA LM-79 and are representative of the configurations shown.

Actual performance may vary due to installation and environmental variables, LED and driver tolerances, and field measurement considerations. It is highly recommended to confirm performance with a photometric layout.

NOTE: Some data may be scaled based on tests of similar (but not identical) luminaires. Contact factory for configurations not shown.

LED Wattage and Lumen Values (Emergency Mode)

Ordering Code

PBL-14L-450-NW-G2-xx-EBP

PBL-14L-600-NW-G2-xx-EBP

PBL-14L-800-NW-G2-xx-EBP

PBL-14L-1050-NW-G2-xx-EBP

LED Qty LED Current (mA) Color Temp.

14

14

14

14

450

600

800

1050

4000

4000

4000

4000

Avg. System Watts

Normal

Mode

23.1

Emergency

Mode

10.4

30.3

40.5

53.8

10.4

10.4

10.4

Lumen Outputs

Normal

Mode

2007

Type 3

Emergency

Mode

1211

Mode

2195

Type 5

Normal Emergency

Mode

1324

2551

3198

3853

1211

1211

1211

2789

3497

4213

1324

1324

1324

For emergency EBP option, publish values are based on initial lumens.

Predicted Lumen Depreciation Data

Predicted performance derived from LED manufacturer’s data and engineering design estimates, based on IESNA LM-80 methodology.

Actual experience may vary due to field application conditions.L

initial lumen output. Calculated per IESNA TM21-11. Published L

70

is the predicted time when LED performance depreciates to 70% of

70

hours limited to 6 times actual LED test hours

Ambient Temperature ° C

25 ° C

Driver mA up to 1050mA

Calculated L

70

Hours

>100,000 hours

L

70

per TM-21

>60,000 hours

Lumen Maintenance % at 60,000 hrs

>95%

PBL_PureForm_bollard 05/20 page 2 of 5

PBL PureForm LED bollard

Site & Area

Dimensions – bollard

9.4" dia.

(23.8cm)

9"

(22.7cm)

Approx. location of motion response if ordered (both sides)

Approx. location of emergency switch if ordered

4.5" dia.

(11.4cm)

Shaft O.D.

Approx. location of photocontrol if ordered

1.9"

(4.9cm)

2.8" dia.

(7.0cm)

Bolt circle

45°

Bolt Pattern

Approx. location of GFCI outlet if ordered

GFCI only available in MGY finish.

4.5" dia.

(11.4cm)

4 x .4" dia.

(1.1cm)

Bolt holes

1.9"

(4.9cm)

42"

(106.6cm)

36"

(91.3cm)

60"

(152.3cm)

PBL_PureForm_bollard 05/20 page 3 of 5

PBL PureForm LED bollard

Site & Area

Specifications

Housing

Main body housing and yoke made of low copper cast aluminum alloy for a high resistance to corrosion. Luminaire shaft features a cylindrical extruded aluminum base housing. Bottom section has a casted ring for ease of assembly. It attaches to base assembly with four (4) hex head set screws. Most electrical components are integrated in the shaft of the bollard by design. This allows for the sleek profile, giving the freedom to have a clean minimalist aesthetic design with minimum obstruction to optical performance. Luminaire housing rated to IP65, tested in accordance to

Section 9 of IEC 60598-1.

SiteWise (SW): SiteWise system includes a controller fully integrated in the luminaire that enables the luminaires to communicate with a dimming signal transmitter cabinet located on site using patented central dimming technology. A locally accessible mobile app allows users to access the system and set functionalities such as ON/OFF, dimming levels and scheduling. Cannot be used with other control options, motion response or photocell options. Additional functionalities are available such as communication with indoor lighting and connection to BMS systems.

Complete information on the control system can be found on the SiteWise website at signify.com/sitewise.

Light engine

Light engine comprises of a 14-LED module made out of aluminum metal clad board fully sealed with optics. Module is RoHS compliant. Color temperatures: 3000K +/- 125K, 4000K, 5000K +/- 200K. Minimum CRI of

70. LED light engine is rated IP66 in accordance to IEC 60598.

Automatic Profile Dimming (CS/CM): Standard dimming profiles provide flexibility towards energy savings goals while optimizing light levels during specific dark hours. Dimming profiles include two dimming settings including dim to 30% or 50% of the total lumen output. When used in combination with not programmed motion response it overrides the controller’s schedule when motion is detected. After 5 minutes with no motion, it will return to the automatic dimming profile schedule.

Energy saving benefits

System efficacy up to 100 lms/W with significant energy savings over Pulse

Start Metal Halide luminaires. Optional control options provide added energy savings during unoccupied periods.

Optical systems

Type 3 and 5 distributions available. Performance tested per LM-79 and

TM-15 certifying its photometric performance. Luminaire designed with

0% uplight (U0 per IESNA TM-15).

Mounting

Base assembly consists of a cast aluminum platform. Assembly is secured and leveled to the mounting foundation with four (4) 3/8" X 8" x 1 1/2" (.953 cm x

20.32 cm x 3.81 cm)-16 anchor bolts on a 2 3/4" (6.9 cm) bolt circle.

Control options

0-10V dimming (DD): Access to 0-10V dimming leads supplied through base of luminaire (for secondary dimming controls by others). Cannot be used with other control options.

Field Adjustable Wattage Selector (FAWS): Luminaire equipped with the ability to manually adjust the wattage in the field to reduce total luminaire lumen output and light levels. Comes pre-set to the highest position at the lumen output selected. Use chart below to estimate reduction in lumen output desired. Cannot be used with other control options or motion response.

Automatic dimming profile scheduled with the following settings:

• CM50/CM30: Median for 8 hours night duration (Ex., 10 PM - 6 AM)

All above profiles are calculated from mid point of the night. Dimming is set for 6 hours after the mid point and 2, or 3 hours before depending of the duration of dimming. Cannot be used with other dimming control options.

Wireless system (LLC): Optional wireless controller integral to luminaire ready to be connected to a Limelight system (sold by others). The system allows you to wirelessly manage the entire site, independent lighting groups or individual luminaires while on-site or remotely. Based on a high-density mesh network with an easy to use web-based portal, you can conveniently access, monitor and manage your lighting network remotely. Wireless controls can be combined with site and area, pedestrian, and parking garage luminaires as well, for a completely connected outdoor solution. Motion response capability can be installed in other luminaires in the mesh or on a remote pod accessory where pod is mounted to pole or wall.

Emergency Battery Pack (EBP): Emergency battery packs included integral to the luminaire, allowing for no field installation of remote emergency equipment. EBP is suitable for use in ambient temperature conditions from 0°C (-32°F) to 40°C (100°F) available on 450mA and up. The system is designed to have a secondary driver with relay to immediately detect AC power loss to power luminaire for a minimum of 90 minutes from the time power is lost. Available with 120-277V, or 'UNV' only.

FAWS

Position

3

4

1

2

7

8

5

6

9

10

Percent of

Typical Lumen Output

25%

50%

55%

65%

75%

80%

85%

90%

95%

100%

Note: Typical value accuracy +/- 5%

Motion response options

Infrared Motion Response Integral (BL-IMRI): Motion Response module is mounted integral to luminaire factory pre-programmed to 20% dimming when not ordered with other control options. BL-IMRI is set/operates in the following fashion: When motion is not detected for a 5 -minute period, luminaires automatically dim to 20% power and light, gradually over a 2

-minute period. Once Motion is detected, luminaires immediately ramp to full power and light output until motion is not detected for a 5-minute period.

5-minute period.

Top

View

39' [12m]

Maximum

Detection

Area

~100°

Bollard

PBL_PureForm_bollard 05/20 page 4 of 5

PBL PureForm LED bollard

Site & Area

Specifications (cont'd)

Electrical

Driver: Driver efficiency (>90% standard). 120-277V available. Bollards with

347V or 480V input require and include a step-down transformer (placed within the bollard shaft) to provide proper input voltage to the LED power supply. Open/short circuit protection. Optional 0-10V dimming to 10% power. RoHS compliant.

Surge protection: Each luminaire is provided as standard with surge protector tested in accordance with ANSI/IEEE C62.45 per ANSI/IEEE

C62.41.2 Scenario I Category C High Exposure 10kV/5kA waveforms for

Line Ground, Line Neutral and Neutral Ground, and in accordance with U.S.

DOE (Department of Energy) MSSLC (Municipal Solid-State Street Lighting

Consortium) Model Specification for LED Roadway Luminaires Appendix D

Electrical Immunity High Test Level 10kV / 5kA. Optional 20kV is available for additional protection.

Ground Fault Interrupt Outlet (GFCI): Optional Class A Rated White 15-Amp

GFCI (Ground Fault Circuit Interrupter) Duplex Outlet provides electrical shock protection and prevents the risk of electrical fire caused by ground fault current.

GFCI only available in MGY finish.

Listings

UL 1598 standard, suitable for Wet Locations. Suitable for use in ambients from -40° to 40°C (-40° to 104°F). The quality systems of this facility have been registered by UL to the ISO 9001 series standards. Most PureForm

PBL configurations are DesignLights Consortium® qualified. Consult DLC

Qualified Products list for more details.

Finish

Each standard color luminaire receives a fade and abrasion resistant, electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC) textured polyester powdercoat finish. The surface treatment achieves a minimum of 1000 hours for salt spray resistant finish in accordance with testing performed and per ASTM B117 standard. Standard colors include bronze (BZ), black (BK), white (WH), dark gray (DGY), and medium gray

(MGY). Consult factory for specs on optional or custom colors.

Warranty

PureForm luminaires feature a 5-year limited warranty.

See signify.com/warranties for complete details and exclusions.

© 2020 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify.

PBL_PureForm_bollard 05/20 page 5 of 5

Signify North America Corporation

200 Franklin Square Drive,

Somerset, NJ 08873

Telephone 855-486-2216

Signify Canada Ltd.

281 Hillmount Road,

Markham, ON, Canada L6C 2S3

Telephone 800-668-9008

All trademarks are owned by Signify Holding or their respective owners.

advertisement

Related manuals

Download PDF

advertisement