Comtrol IOLB-7014 User Guide
Advertisement
Advertisement
IO-Link Block
IOLB-7014
(4 Channel Analog Input)
User Guide
Trademark Notices
Other product names mentioned herein may be trademarks and/or registered trademarks of their respective owners.
First Edition, March 22, 2018
Copyright © 2018. Comtrol Corporation.
All Rights Reserved.
Comtrol Corporation makes no representations or warranties with regard to the contents of this document or to the suitability of the Comtrol product for any particular purpose. Specifications subject to change without notice. Some software or features may not be available at the time of publication. Contact your reseller for current product information.
Document Number: 2000645 Rev. A
Table of Contents
IOLB-7014 User Guide : 2000645 Rev. A Table of Contents - 3
4 - Table of Contents IOLB-7014 User Guide : 2000645 Rev. A
Overview
IOLB-7014 Module Overview
The IOLB-7014 provides four configurable differential analog inputs. The IOLB-7014 is intended to be connected directly to an IO-Link Master without an additional coupler box.
The small IOLB-7014 form factor of only 126 x 30 x 26.5 mm (h x w x d), which means that they are suitable for use where space is at a premium. The small mass of the IOLB-7014 module facilitates applications with mobile I/O interface (for example, a robot arm).
The robust design of the IOLB-7014 module enables them to be used directly at the machine. Control cabinets and terminal boxes are now no longer required. The module is fully sealed and therefore ideally prepared for wet, dirty or dusty conditions (IP67).
Pre-assembled cables significantly simplify IO-Link and signal wiring. Very few wiring errors are made, so that commissioning is optimized. In addition to pre-assembled IO-Link, power and sensor cables, field- configurable connectors and cables are available for maximum flexibility. Sensors and actuators are connected through M12 connectors.
Configurable Analog Differential Inputs
The IOLB-7014has four analog inputs that can be parameterized individually so that they process either signals in the range of -10 V to
+10 V or in the range of 0/4 mA through 20 mA. The voltage or the input current is digitized with a resolution of 16 bits and transported galvanically separated to the higher-level automation device.
The four input channels are differential inputs and have a common, internal ground potential. The input filters and associated conversion times can be set in a wide range. The scaling of the inputs can be changed if necessary; Automatic limit monitoring is also available.
Parameterization is done through IO-Link. The parameters are stored on the module.
Connector Assignment
IOLB-7014 User Guide : 2000645 Rev. A Overview - 5
IOLB-7014 LEDs
IOLB-7014 LEDs
This subsection provides information about the IOLB-7014 LEDs.
X1 (IO-Link LED)
Description
Off IO-Link communication not active.
Flashing green (1 Hz) IO-Link communication active.
Lit (Red) Short circuit on C / Q line or overheating.
Power Supply LEDs
24V (L+)
24 (2L+)
Off
Green
Red
Off
Green
Red
Description
Voltage L+ Unavailable
Voltage L+ Ok
Voltage L+ Too Low
Voltage 2L+ Unavailable
Voltage 2L+ Ok
Voltage 2L+ Too Low, Short Circuit
Analog LED
R (Left LED)
E (Right LED)
Led Status
Off
Green
Off
Red
Description
No data transmission to the A / D converter.
Data transfer to the A / D converter.
Functioning properly.
Error: Wire break or measured value out of range.
6 - Overview IOLB-7014 User Guide : 2000645 Rev. A
IOLB-7014 Technical Specifications
IOLB-7014 Technical Specifications
IOLB-7014 Technical Specifications
Hardware
Communication Interface
Enclosure
Ingress Protection Rating
Potting Compound
Ports
Transmission Speed
Connector Type (IO-Link)
Connector Type (Analog inputs)
Connector Contacts
Mounting Method
Mounting Mechanism
LED Indicators
Dimensions (L x W x H)
Weight
IO-Link
Industrial housing PA6 (polyamide)
IP65, IP66, IP67 (conforms to EN 60529)
Polyurethane
1 – IO-Link
4 – Analog Inputs
COM3 = 230.4 Kbps
M12, 5-poles, A-coded (male)
M12, 4-poles, A-coded (female)
Plated CuZn
Machine or panel mount
Two mounting holes on the product for M3 screws
IO-Link Communication status, Power Input L+, Power
Input 2L+, Analog Input status
126 x 30 x 26.5mm
5“ x 1.2“ x 1“
125g
4.4 oz
Electrical Specifications
Operating Voltage
Nominal Voltage
Electronic Module Supply
Supply of Sensors
Electrical Isolation
Current Consumption (Module Electronics)
18 – 30 VDC
24 VDC
L+ (Pin 1, 3 on IO-Link Connector X1)
2L+ (Pin 2, 5 on IO-Link Connector X1)
Yes (between L+ and 2L+)
100 mA from L+
IOLB-7014 User Guide : 2000645 Rev. A Overview - 7
IOLB-7014 Technical Specifications
IO-Link Device ID
IO-Link Connector
Specification Version
Features
Process Data Input (PDI)
Process Data Input (PDO)
Process Image
IOLB-7014 Technical Specifications
IO-Link Communication Specifications
Communication
Operating Mode
Standard
IO-Link
COM3 (230.4 kbps)
IEC61131-9
7014 (decimal)
00 1B 66 (hex)
1 x M12, 5-poles, A-coded
IO-Link V1.1
Data storage
16 Bytes
0 Bytes
Inputs: 4 x 16 bit
Status: 4 x 16 bit
Analog Input Specifications
Number of Analog Inputs
Input Connectors
Input Types
Internal Resistance
Resolution
Input Filter
Input Filter Cut-off Frequency
Conversion Time
Measurement Error
Common Mode Voltage UCM
4
4 x M12, 5-pole, A-coded socket
Configurable:
• 0 V ... + 10 V
• -10 V ... + 10V
• 0 mA ... 20 mA
• 4 mA ... 20 mA
> 200K ohms (typ. 85 ? + diode voltage)
16 bits (incl. Sign)
Configurable
5 kHz
~ 100 microseconds
<± 0.3% (relative to the full-scale value)
Max. 35 V
8 - Overview IOLB-7014 User Guide : 2000645 Rev. A
IO-Link Basics
Environmental Specifications
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Shock and Vibrations
Regulatory Approvals
IOLB-7014 Technical Specifications
-25°C to +60°C
-40°C to +85°C
10% to 95%
10% to 95%
EN 60068-2-6 EN 60068-2-27
Emissions
Immunity
Safety Approvals
Other
Approvals
EN 61000-6-4
International Standard IEC 61000-6-4
EN61000-6-2
International Standard IEC 61000-6-2
UL508
IP65, IP66, IP67 (conforms to EN 60529)
2011/65/EU (RoHS2) Directive
CE, UL, RoHS2
IO-Link Basics
IO-Link is a communications system for connecting intelligent sensors and actuators to an automation system in IEC 61131-9 under the name Single-drop digital communication interface for small sensors and actuators
(SDCI).
Both the electrical connection data and the communication protocol are standardized and in the IO-Link specification summarized.
IO-Link Specification
The development of IOLB-7014 was subject to the IO-Link specification 1.1. The IO-Link specification is included in the IEC standards and is accepted as IEC 61131-9 in an extended form. In this case, the new designation voltage SDCI is introduced. Comtrol supports as participants in the appropriate for the development of IO-Link and forms specification changes in its products from.
IOLB-7014 User Guide : 2000645 Rev. A Overview - 9
IO-Link System
IO-Link System
An IO-Link system consists of an IO-Link Master, one or more IO-Link devices and sensors or actuators. The
IO-Link Master provides the interface to the higher-level controller and controls the communication with the connected IO-Link devices. The Comtrol IO-Link Master series has four or eight IO-Link ports at which each one IO-Link device can be connected. therefore IO-Link is not fieldbus, but rather is a peer-to-peer connection
(see figure below).
The connected IO-Link devices have individual parameter information detected during automatic scanning with the Comtrol IO-Link Master. Refer to
Configuring the IOLB-7014 on Page 21 for more information.
10 - Overview IOLB-7014 User Guide : 2000645 Rev. A
Structure of IO-Link Communication
Structure of IO-Link Communication
The structure of the IO-Link communication is shown in the following figure. In particular, this represents the sequence in the automatic scanning of the IO-Link ports.
• If the stored consistent with the read parameters, so changes the IO-Link device in the PREOP status.
• If it is an IO-Link device specification V1.1, the parameter server is now running. If it is in an IO-Link device according to V1.0, this step is omitted and connected directly in the operating room.
• Finally, the cycle time is written and switched the device in the operating room. After that is the master in the cyclical data exchange with the slave.
IOLB-7014 User Guide : 2000645 Rev. A Overview - 11
Structure of IO-Link Communication
12 - Overview IOLB-7014 User Guide : 2000645 Rev. A
Hardware Installation
This section provides installation information for the IOLB-7014.
Mounting the IOLB-7014
The following table provide information that you may require for installation.
IOLB-7014
Housing material
Casting compound
Mounting
Metal parts
Contacts
Power feed through (maximum)
Installation position
Protection class
PA6 (polyamide)
Polyurethane two fastening holes Ø 3 mm for M3
Brass, nickel-plated
CuZn, gold-plated
4 A
Any
IP65, IP66, IP67 (conforms to EN 60529)
Dimensions (H x W x D)
Weight
126 x 30 x 26.5 mm
Approximately 125 g
Note: While mounting the IOLB-7014, protect all connectors against contamination. All connectors must have either a cable or plug to guarantee IP67 rating.
Keep the following in mind when mounting the IOLB-7014.
• Mount the IOLB-7014 with two M3 bolts.
• The bolts must be longer than 15 mm. The fixing holes of the modules are not threaded.
• When assembling, remember that the connectors increases the overall height.
IOLB-7014 User Guide : 2000645 Rev. A Hardware Installation - 13
Connecting Power to the IOLB-7014
Connecting Power to the IOLB-7014
The power supply that you connect to the IOLB-7014 must meet the following requirements:
• 24VDC supplied by an isolating source and protected by means of a fuse (in accordance with UL248), rated maximum 4A or a 24VDC power source that satisfies NEC Class 2.
• A NEC Class 2 power supply shall not be connected in series or parallel with another (Class 2) power source.
• To meet the UL requirements, the IOLB-7014 must not be connected to unlimited power sources!
Note: To meet the UL requirements, the IOLB-7014 must not be connected to telecommunications networks and must be operated at the ambient temperature range specified in the specifications.
For additional information, see
IOLB-7014 Technical Specifications on Page 7.
1
2
3
4
5
Pin Input - Male
24V (L+)
24V (L2+)
GND (L-)
IO-Link (C/Q)
GND (2M)
The following Comtrol cables and M12 Y-splitter can be used to connect the IOLB-7014 to the Comtrol IO-
Link Master.
Comtrol Part Number Description
1200143
Varies by length
†
Y Splitter, M12 5-poles, A-Coded, M to 2F
Sensor cable, M12 5-poles, A-coded, M to F
Varies by length
†
Power Cable, Comtrol IOLB, M12 A-Coded, M to wires
†
Contact Comtrol Sales for the part number.
Use the following procedure to apply power the IOLB-7014.
Note: It is recommended to pull the M12 connectors tight with a nut torque of 0.6 Nm.
14 - Hardware Installation IOLB-7014 User Guide : 2000645 Rev. A
Connecting Power to the IOLB-7014
1.
Connect the M12 Y splitter to an available Comtrol IO-Link Master IO-Link port.
2.
Connect the white and green wires of the Comtrol IOLB power cable to a
24V power supply. a.
Make sure that the 24V power supply is not energized during the wiring. b.
Connect the white wire to the positive 24V terminal. c.
Connect the green wire to the negative 24V terminal on the power supply.
3.
Connect the M12 connector end of the Comtrol IOLB power cable to Port
2 on the Y-Splitter.
IOLB-7014 User Guide : 2000645 Rev. A Hardware Installation - 15
Connecting Power to the IOLB-7014
4.
Connect the 5-pole (M12) sensor cable between Port 1 on the Y-splitter and the IOLB-7014 IO-Link Port
X1.
5.
Apply power to the 24V power supply connected to the IOLB-7014.
6.
Apply power to the Comtrol IO-Link Master
7.
Verify that the following LEDs are lit:
• Green 24V (L+) and 24V (2L+) LEDs on the IOLB-7014
• Green IO-Link on the Comtrol IO-Link Master is lit
• Amber DI LED on Comtrol IO-Link Master is lit (power is being injected into the DI pin to power the IOLB-7014)
Note:
Refer to IOLB-7014 LEDs on Page 6 for detailed LED information.
16 - Hardware Installation IOLB-7014 User Guide : 2000645 Rev. A
Connecting Analog Devices
Connecting Analog Devices
This table provides signal information for the analog connectors on the IOLB-7014.
Pin
1
2
3
4
5
Description
Power supply 2L+
Input +
Ground 2M
Input -
Shield
Signal Connection - Analog Voltage Input
The signal is measured using a differential input (Pin 2 and Pin 4). Either a 4-wire or 2-wire voltage device can be connected. The voltage range is set through parameters.
Note: The device is functioning correctly if the Run LED is lit and the Error LED is not lit.
LED
Connector Display Meaning
M12 Socket
1 -4
R
Left
E
Right
Off
Green
Off
Red
No data transmission to A/ D converter.
Data transmission to A/D converter.
Correct operation.
Error: wire breakage or measured value out of range.
IOLB-7014 User Guide : 2000645 Rev. A Hardware Installation - 17
Signal Connections - Current Inputs
Signal Connections - Current Inputs
The signal is measured using a differential signal (Pin 2 and Pin 4). A 4-wire, 3-wire, or 2-wire current device can be connected.
LED
Connector
M12 Socket
1 - 4
R left
E right
Display Meaning
Off
Green
Off
Rot
No data transmission to A/ D converter
Data transmission to A/D converter
Correct operation
Error: wire breakage or measured value out of range
18 - Hardware Installation IOLB-7014 User Guide : 2000645 Rev. A
Comtrol IO-Link Master Diagnostic Page
Comtrol IO-Link Master Diagnostic Page
You can also verify the IOLB-7014 operation by viewing the Comtrol IO-Link Master IO-Link Diagnostics page.
1.
Log into the Comtrol IO-Link Master using the IP address.
2.
Click Diagnostics | IO-Link .
IOLB-7014 User Guide : 2000645 Rev. A Hardware Installation - 19
Comtrol IO-Link Master Diagnostic Page
20 - Hardware Installation IOLB-7014 User Guide : 2000645 Rev. A
Configuring the IOLB-7014
This section discusses loading the IODD on the Comtrol IO-Link Master.
Locating the IOLB-7014 IODD Files
The IOLB-7014 IODD files are located on the Comtrol download site using one of these addresses:
• http: //downloads.comtrol.com/IO_Link_Block/IOLB-7014/IODD/
• ftp://ftp.comtrol.com/IO_Link_Block/IOLB-7014/IODD/
Loading the IODD Files Onto the Comtrol IO-Link Master
Use the following procedure to load the IOLB-7014 IODD file.
1.
If necessary, download the IOLB-7014 IODD files.
2.
Log into the Comtrol IO-Link Master using the IP address.
3.
Click Attached Devices .
4.
Click the UPLOAD FILE button.
IOLB-7014 User Guide : 2000645 Rev. A Configuring the IOLB-7014 - 21
Loading the IODD Files Onto the Comtrol IO-Link Master
5.
Click the CHOOSE FILE button.
6.
Browse to and select the Comtrol-IOLB-7014-20180301-IODD1.1.zip
file.
7.
Click the UPLOAD button.
8.
Click the Ok button.
Note: The above message is expected behavior because the .icon file is not required by the XML file.
22 - Configuring the IOLB-7014 IOLB-7014 User Guide : 2000645 Rev. A
Loading the IODD Files Onto the Comtrol IO-Link Master
9.
Click the SUMMARY link to verify that the correct IODD file loaded.
IOLB-7014 User Guide : 2000645 Rev. A Configuring the IOLB-7014 - 23
Configuring the IOLB-7014
Configuring the IOLB-7014
After loading the IODD file, you are ready to configure the channels on the IOLB-7014.
1.
If necessary, log into the Comtrol IO-Link Master.
2.
Click Attached Devices | Port x, where x is the IO-Link port that you have attached the IOLB-7014.
3.
Click the EDIT button.
Note: For information about using the Comtrol IO-Link Master, refer to the help system or appropriate User
Guide for the model.
24 - Configuring the IOLB-7014 IOLB-7014 User Guide : 2000645 Rev. A
Configuring the IOLB-7014
4.
Make the necessary changes to reflect the analog devices that you intend on connecting and click the
SAVE button.
Note:
See Filters (Common to All Input Channels)
on Page 30 and IOLB-7014 Parameters on Page 41 for
more information.
IOLB-7014 User Guide : 2000645 Rev. A Configuring the IOLB-7014 - 25
Configuring the IOLB-7014
After the page is saved, note that the changes have been implemented.
26 - Configuring the IOLB-7014 IOLB-7014 User Guide : 2000645 Rev. A
Technical Data Overview
This section provides supporting information for the IOLB-7014:
•
Analog Input Range Settings (Index 14336) on Page 27
•
Analog Input Channel Parameters (Common) on Page 27
•
Filters (Common to All Input Channels) on Page 30
•
Analog Specifications on Page 32
•
Data Flow and Correction Calculation on Page 35
Note:
Refer to Object Descriptions on Page 41 for more information.
Analog Input Range Settings (Index 14336)
Use Index 14336 (Sub-indexes 1-4) to set the appropriate voltage or current range for each channel.
Analog Input Channel Parameters (Common)
The following subsections provide detailed channel parameter information that you may need.
•
Presentation (Sub-Index 02) on Page 28
•
Siemens Bits (Sub-Index 05) on Page 28
•
Enable Limit 1 | Enable Limit 2 (Sub-Indexes 7 and 8) on Page 28
•
Swap Limit Bits (Sub-Index 14) on Page 28
•
Limit 1 | Limit 2 (Sub-Indexes 19 and 20) on Page 29
•
Enable Vendor Calibration (Sub-Index 11) on Page 29
•
Enable User Scale (Sub-Index 1) on Page 30
•
User Scale Offset (Sub-Index 17) on Page 30
•
User Scale Gain (Sub-Index 18) on Page 30
•
Enable User Calibration (Sub-Index 10) on Page 30
•
User Calibration Offset Sub-Index 23) on Page 30
•
User Calibration Gain (Sub-Index 24) on Page 30
The following subsections discuss common sub-indexes for the these channel parameter Indexes.
Analog Input Channel Index
3
4
1
2
2048
2064
2080
2096
Note: See
Filters (Common to All Input Channels) on Page 30 for information about filtering.
IOLB-7014 User Guide : 2000645 Rev. A Technical Data Overview - 27
Presentation (Sub-Index 02)
Presentation (Sub-Index 02)
Measured value can be output in the following formats: Signed integer (default) and Unsigned integer
(absolute value) in two's complement format (signed integer).
• Signed Integer Representation: The negative output value is represented in two’s complement
(negated + 1). Maximum representation range for 16 bits = -32768 to +32767dec.
Input signal Value
+/- 10 V 0 - 20 mA 4 - 20 mA 0 - 10 V Decimal Hexadecimal
10 V
5 V
0 V
-5 V
20 mA
10 mA
-
0 mA
20 mA
12 mA
-
4 mA
10 V
5 V
-
0 V
32767
16383
0
-16383
0x7FFF
0x3FFF
0x0000
0xC001
-10 V -32767 0x8000
• Unsigned Integer Representation : The output value is represented with 15-bit resolution without sign, therefore polarity detection is no longer possible. Maximum representation range for 16 bits = 0 to
+32767dec.
• Absolute Value With MSB : The output value is displayed in magnitude-sign format: MSB=1 (highest bit) in the case of negative values. Maximum representation range for 16 bits = -32768 to +32767dec.
10
5 V
0 V
-5
-10
Input values (+/- 10 V) Representation (values dec. / values hex.) unsigned integer absolute value with MSB as sign
32767 / 0x7FFF
16383 / 0x3FFF
32767 / 0x7FFF
16383 / 0x3FFF
0 / 0x0000
16384 / 0x4000
32767 / 0x7FFF
0 / 0x0000
[-16384] / 0xC000
[-32767] / 0xFFFF
Siemens Bits (Sub-Index 05)
When set to 1, the status displays are superimposed on the lowest three bits of the process data input. In the event that an overrange or underrange
occurs, Bit 0 is set. See Data Flow and Correction Calculation on Page
35 and PDI (Process Data Input) Channel Information on Page 38 for more information.
Enable Limit 1 | Enable Limit 2 (Sub-Indexes 7 and 8)
Sub-index 7 or 8 respectively serve to enable the Limit 1 and Limit 2 value monitoring.
Swap Limit Bits (Sub-Index 14)
When set to 1, the limits are inverted. See Limit 1 | Limit 2 (Sub-Indexes 19 and 20) on Page 29.
28 - Technical Data Overview IOLB-7014 User Guide : 2000645 Rev. A
Limit 1 | Limit 2 (Sub-Indexes 19 and 20)
Limit 1 | Limit 2 (Sub-Indexes 19 and 20)
When the analog value (Y
S
) exceeds or falls below the value entered in Limit 1 and Limit 2, then the Limit
Limit Swap (Sub-Index 14) Limit Bits (2 Bits) Value
FALSE (default)
TRUE
0: not active
1: value <limit
2: value> limit
3: value = limit value
0: not active
1: value> limit
2: value <limit
3: value = limit value
Note: The limit evaluation is based on a Signed representation. The conversion to the desired presentation
(Sub-Index 02) takes place only after the limit evaluation.
Limit Analysis Example:
Port1, channel 1; Limit 1 and Limit 2 enabled, limit 1 = 2.8 V, limit 2 = 7.4 V, presentation: signed integer, swap = false.
Input Channel 1 Limit 1 Bits Limit 2 Bits
1.8 V
2.8 V
4.2 V
8.5 V
0x01hex
0x03hex
0x02hex
0x02hex
0x01hex
0x01hex
0x01hex
0x02hex
Enable Vendor Calibration (Sub-Index 11)
When vendor calibration is enabled, the factor calibration (offset and gain) is applied to the raw input signal.
Vendor calibration parameters cannot be changed. The following tables provide information about vendor calibration values, which is displayed under the Observation group for each channel.
3
4
1
2
Channel Index
2063
2079
2095
2111
Sub-Index
01
02
03
04
05
06
Description
R0 offset (vendor compensation)
R0 gain (vendor compensation)
R1 offset (vendor compensation)
R1 gain (vendor compensation)
R2 offset (vendor compensation)
R2 gain (vendor compensation)
IOLB-7014 User Guide : 2000645 Rev. A Technical Data Overview - 29
Enable User Scale (Sub-Index 1)
Enable User Scale (Sub-Index 1)
User scaling is enabled using Sub-Index 1. User scale provides offset and gain as discussed in the next two subsections.
Refer to Data Flow on Page 35 for related information.
User Scale Offset (Sub-Index 17)
When User Scale is enabled using Sub-Index 1, use Sub-index 17 to configure the offset.
User Scale Gain (Sub-Index 18)
When User Scale is enabled using Sub-Index 1, use Sub-index 18 to configure the gain.
Enable User Calibration (Sub-Index 10)
User calibration is enabled using Sub-Index 10. User calibration provides offset and gain as discussed in the next two subsections.
Refer to Data Flow on Page 35 for related information.
User Calibration Offset Sub-Index 23)
When user calibration is enable using Sub-Index 10, use Sub-index 23 to configure the offset.
User Calibration Gain (Sub-Index 24)
When user calibration is enable using Sub-Index 10, use Sub-index 24 to configure the gain.
Filters (Common to All Input Channels)
This subsection provides the following information:
•
Filter Enable (Index 2048 | Sub-Index 6)
•
Filter Setting (Index 2048 | Sub-Index 21)
Filter Enable (Index 2048 | Sub-Index 6)
When the filter is enabled, the filter settings are applied to all input channels.
Filter Setting (Index 2048 | Sub-Index 21)
The IOLB-7014 incorporates a digital filter which, depending on the selected setting, can adopt the characteristics of a Finite Impulse Response filter (FIR filter), or an Infinite Impulse Response filter (IIR filter). The filter can also be deactivated (default).
Note: The filter frequencies are set for all channels of the IOLB-7014.
30 - Technical Data Overview IOLB-7014 User Guide : 2000645 Rev. A
FIR Filter
FIR Filter
The filter performs a notch filter function and determines the conversion time of the module.
The higher the filter frequency, the faster the conversion time. A 50 Hz and a 60 Hz filter are available.
Notch filter means that the filter has zeros
(notches) in the frequency response at the filter frequency and multiples thereof, that is, it attenuates the amplitude at these frequencies.
The FIR filter functions as a non-recursive filter.
Note: Typical attenuation curve of notch filter at 50 Hz
Filter
50 Hz FIR
60 Hz FIR
Filter characteristics FIR filter (Channels 1- 4)
Attenuation
> 50 dB
> 40 dB
Limit frequency (-3 dB)
22 Hz
26 Hz
Conversion time
625 µs
521 µs
IIR Filter
The filter with IIR characteristics is a discrete time, linear, time invariant filter that can be set to eight levels
(level 1 = weak recursive filter, up to level 8 = strong recursive filter).
The IIR can be understood to be a moving average value calculation after a low-pass filter.
IIR Filter
IIR 1
IIR 2
IIR 3
IIR 4
IIR 5
IIR 6
IIR 7
IIR 8
-3 dB Limit Frequency
(50 µs Sample Time)
400 Hz
220 Hz
100 Hz
50 Hz
24 Hz
12 Hz
6,2 Hz
3,0 Hz
IOLB-7014 User Guide : 2000645 Rev. A Technical Data Overview - 31
Analog Specifications
Analog Specifications
This subsection contains the following information:
•
•
± Measuring Error [% of the Full Scale Value] (Also: Measurement Error) on Page 32
•
Differential Typification on Page 33
•
Correction Calculation (0 to 20mA) on Page 36
Full Scale Value
An I/O device with an analog input measures over a nominal measuring range that is limited by an upper and a lower limit (initial value and end value); these can usually be taken from the IOLB-7014 designation. The range between the two limits is called the measuring span and corresponds to the equation (end value - initial value). Analogous to pointing devices this is the measuring scale (see IEC 61131) or also the dynamic range.
For the above examples this means:
• Measuring range 0 to 10V: asymmetric unipolar, full scale value = 10V, measuring span = 10V
• Measuring range 4 to 20mA: asymmetric unipolar, full scale value = 20mA, measuring span = 16mA
• Measuring range -10 to +10V: symmetric bipolar, full scale value = 10V, measuring span = 20V
± Measuring Error [% of the Full Scale Value] (Also: Measurement Error)
The relative measuring error is referenced to the full scale value and is calculated as the quotient of the largest numerical deviation from the true value ( measuring error ) referenced to the full scale value.
Measurement Error = Maximum Deviation/Full Scale Value
The measuring error is generally valid for the entire permitted operating temperature range, also called the usage error limit and contains random and systematic portions of the referred device (that is, all influences such as temperature, inherent noise, aging, etc.).
It is always to be regarded as a positive/negative span with ±, even if it is specified without ± in some cases.
The maximum deviation can also be specified directly.
Example : Measuring range 0 to 10 V and measuring error < ± 0.3 % full scale value - maximum deviation
±30mV in the permissible operating temperature range.
32 - Technical Data Overview IOLB-7014 User Guide : 2000645 Rev. A
Differential Typification
Differential Typification
This diagram shows the DIFF module.
Note: Dashed lines indicate that the respective connection may not necessarily be present in each DIFF module.
The basic rule:
• Analog measurements always take the form of voltage measurements between two potential points. For voltage measurements a large R is used, in order to ensure a high impedance. For current measurements a small R is used as shunt. If the purpose is resistance measurement, corresponding considerations are applied.
Comtrol generally refers to these two points as input+/signal potential and input-/reference potential.
For measurements between two potential points two potentials have to be supplied.
Regarding the terms single-wire connection or three-wire connection , please note the following for pure analog measurements: three- or four-wire connections can be used for a sensor supply, but are not involved in the actual analog measurement, which always takes place between two potentials/wires.
• The term electrical isolation should be clarified in advance with regard to the channel connection a distinction is made in terms of how the channels:
Within a module relate to each other, or
Of several modules relate to each other.
The property of electrical isolation indicates whether the channels are directly connected to each other.
• The IOLB-7014 features electrical isolation between the field/analog side and the IO-Link side.
• Differential channels are not electrically isolated channel to channel.
• Analog measuring channels are subject to technical limits, both in terms of the recommended operating
Page 7 for information about channel limits.
Differential Explanation
• Differential measurements provide the most flexibility. You can choose both connection points, input+/ signal potential and input-/reference potential, within the framework of the technical specification.
• Since a differential input is configured symmetrically internally (see diagram), there will be a midpotential (X) between the two supplied potentials that is the same as the internal ground/reference ground for this channel. The technical property VCM (common-mode voltage) indicates the degree to which the mean voltage of the channels may differ.
IOLB-7014 User Guide : 2000645 Rev. A Technical Data Overview - 33
Typification of the 2/3/4-Wire Connection of Current Sensors
• The internal reference ground may be accessible as connection point at the IOLB-7014, in order to stabilize a defined GND potential in the IOLB-7014. In this case it is particularly important to pay attention to the quality of this potential (noiselessness, voltage stability). At this GND point a wire may be connected to make sure that V
CM max
is not exceeded in the differential sensor cable. If differential channels are not electrically isolated, usually only one V
CM max
is permitted.
• Differential measurement in combination with correct sensor wiring has the special advantage that any interference affecting the sensor cable (ideally the feed and return line are arranged side by side, so that interference signals have the same effect on both wires) has very little effect on the measurement, since the potential of both lines varies jointly (hence the term common mode). In simple terms: Common-mode interference has the same effect on both wires in terms of amplitude and phasing.
• Nevertheless, the suppression of common-mode interference within a channel or between channels is subject to technical limits, which are specified in the
IOLB-7014 Technical Specifications on Page 7.
Typification of the 2/3/4-Wire Connection of Current Sensors
Current transducers/sensors/field devices (referred to in the following simply as sensor ) with the industrial
0/4-20mA interface typically have internal transformation electronics for the physical measured variable
(temperature, current, etc.) at the current control output. These internal electronics must be supplied with energy (voltage, current). Thus separates the sensors into self-supplied (2-wire) or externally supplied sensors
(3-wire or 4-wire):
• Self-supplied sensors
The sensor draws the energy for its own operation via the sensor/signal wires + and -. So that enough energy is always available for the sensor’s own operation and open-circuit detection is possible, a lower limit of 4mA has been specified for the 4-20mA interface; i.e. the sensor allows a minimum current of 4mA and a maximum current of
20mA to pass.
For a 2-wire connection; see IEC60381-1
Such current transducers generally represent a current sink and thus like to sit between + and – as a variable load . Refer also to the sensor manufacturer’s information.
Therefore, they are to be connected accordingly:
• The sensor draws the energy/operating voltage for its own operation from two supply wires of its own. One or two further sensor wires are used for the signal transmission of the current loop:
• Sensor cable: according to the terminology such sensors are to be connected to single- ended inputs in 3 wires with +/-/Signal lines and if necessary a cable shield
• Sensor cables: In the case of sensors with 4-wire connection according to +-/+Signal/-Signal, you must check whether +Signal may be connected to +Supply or –Signal to –Supply.
Yes: then you can connect accordingly to a Comtrol single-ended input .
The differential input for +Signal and –Signal is to be selected; +Supply and –Supply are to be connected via additional wires.
Note: Expert organizations such as NAMUR demand a usable measuring range <4mA/>20mA for error detection and adjustment, see also NAMUR NE043.
34 - Technical Data Overview IOLB-7014 User Guide : 2000645 Rev. A
Data Flow and Correction Calculation
Data Flow and Correction Calculation
This subsection contains the following topics:
•
•
Correction Calculation (+/- 10V) on Page 36
Data Flow
The flowchart below shows demonstrative the data flow of the IOLB-7014 (processing of the raw data).
IOLB-7014 User Guide : 2000645 Rev. A Technical Data Overview - 35
Correction Calculation (+/- 10V)
Correction Calculation (+/- 10V)
This figure shows the correcting calculation of the raw values to the output values if the range is over- or undershot.
Correction Calculation (0 to 20mA)
This figure shows the correcting calculation of the raw values to the output values if the range is over- or undershot.
36 - Technical Data Overview IOLB-7014 User Guide : 2000645 Rev. A
Correction Calculation (4 to 20mA)
Correction Calculation (4 to 20mA)
This figure shows the correcting calculation of the raw values to the output values if the range is over- or undershot.
Correction Calculation (0 to 10V)
This figure shows the correcting calculation of the raw values to the output values if the range is over- or undershot.
Process Data Calculations
The IOLB-7014 records measured values continuously and places the raw value of its A/D converter into the
ADC raw value objects 2062, 2078, 2094, and 2110. The calculation of the correction with the vendors calibration values takes place after each acquisition of the analog signal. User scaling then follows
(optionally):
Y
H
= (X
ADC
-B
H
) * A
H
Measured value following vendor calibration (Y
H
= X
ADC
), if vendor calibration is disabled.
Y
A
= (Y
H
-B
A
) * A
A
Measured value following user calibration (Y
A
= Y
H
), if user calibration is disabled.
Y
S
= Y
A
* A
S
* 22-16 + B
S
Measured value following user scale Y
S
= Y
A
, if user scale is disabled.
IOLB-7014 User Guide : 2000645 Rev. A Technical Data Overview - 37
PDI (Process Data Input) Channel Information
Y
H
B
A
A
A
Y
A
Name
X
ADC
B
H
A
H
B
S
A
S
Y
S
Designation
Output value of the A/D converter
Vendor calibration offset (only changeable if Indexes
2048, 2064, 2080, or 2096; Sub-index 11 is set)
Vendor calibration gain (only changeable if Indexes
2048, 2064, 2080, or 2096; Sub-index 11 is set)
Measuring value after manufacturer calibration
User calibration offset
User calibration gain
Measuring value after user calibration
User scaling offset (can be activated via indexes 2048,
2064, 2080, or 2096 Sub-index: 1)
User scaling gain (can be activated via indexes 2048,
2064, 2080, or 2096 Sub-index: 1)
Process data for controller, measuring value after user scale
Index
2062, 2078, 2094, 2110
-
2063, 2079, 2095, 2111
2063, 2079, 2095, 2111
-
-
2048, 2064, 2080, 2096
2048, 2064, 2080, 2096
2048, 2064, 2080, 2096
2048, 2064, 2080, 2096
PDI (Process Data Input) Channel Information
This image illustrates the PDI channel data for one channel on the IOLB-7014.
Byte 4
Status
Byte 3
Unused
Byte 2
MS
INT16
Byte 1
LS
INT16
23
24
14
18
Sub-Index
01
01, 03, 05
02, 04, 06
Where :
• UR is Under-range
• OR is Over-range
• L1LS is Limit 1 LS
• L1MS is Limit 1 MS
• L2LS is Limit 2 LS
• L2MS is Limit 2 MS
• Siemens bits are superimposed over 3 bits of PDI
38 - Technical Data Overview IOLB-7014 User Guide : 2000645 Rev. A
This image illustrates all 16 PDI data bytes from the IOLB-7014.
PDI (Process Data Input) Channel Information
IOLB-7014 User Guide : 2000645 Rev. A Technical Data Overview - 39
PDI (Process Data Input) Channel Information
40 - Technical Data Overview IOLB-7014 User Guide : 2000645 Rev. A
Object Descriptions
This section provides supporting information for the IOLB-7014 object descriptions.
IOLB-7014 Parameters
Note: The Index and Sub-indexes are displayed as decimal numbers, which match the Comtrol IO-Link
Master.
20
21
22
23
16
17
18
Index Subindex
24
14336
14336
14336
14336
01
02
03
04
Name Meaning Data type Flags
Vendor Name
Vendor Text
Product Name
IDENTIFICATION
Comtrol Corporation www.comtrol.com
Comtrol IOLB-7014
StringT64
StringT64
StringT64
Product Text
Serial Number
Hardware Version 00
Firmware Version 02.08
Application
Specific Tag
4-Ch Analog Input Module, M12 StringT64
9640-XXXXXX StringT16
*******************
StringT64
StringT64
StringT32
Input type Ch1
ANALOG INPUT RANGE SETTINGS
Input signal range for Channels
0 -10 to +10 V
1 0 to 20 mA
2 4 to 20 mA
6 0 to 10 V
UINT16
Input type Ch2
Input type Ch3
Input type Ch4
Input signal range for Channel 2
(values see Channel 1)
Input signal range for Channel 3
(values see Channel 1)
Input signal range for Channel 4
(values see Channel 1)
UINT16
UINT16
UINT16
RO
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
Default
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0x0000 (0dec)
0x0000 (0dec)
0x0000 (0dec)
0x0000 (0dec)
IOLB-7014 User Guide : 2000645 Rev. A Object Descriptions - 41
IOLB-7014 Parameters
Index Subindex
2048
2048
2048
2048
2048
2048
2048
2048
2048
2048
2048
2048
2048
2048
2048
2048
01
02
05
07
08
10
11
14
17
18
19
20
23
24
Name Meaning Data type Flags
ANALOG INPUT CHANNEL 1 SETTINGS
Enable user scale 1 User scale is enabled BOOLEAN RW
0
1
Signed presentation
Unsigned presentation
BIT3 RW
Siemens bits
2
1
Absolute value with
MSB as sign
Status displays are superimposed on the lowest three bits in the status word.
BOOLEAN RW
Enable limit 1
Enable limit 2
Enable user calibration
Enable vendor calibration
1
1
1
1
Enable Limit 1
Enable Limit 2
User calibration is enabled
Vendor calibration is enabled
BOOLEAN RW
BOOLEAN RW
BOOLEAN
BOOLEAN
RW
RW
Swap limit bits
User scale offset
User scale gain
Limit 1
Limit 2
1
Swaps the two limit bits to be compatible to older hardware versions.
User scale offset
The gain is represented in fixed- point format, with the factor 2-
16. A value of 1 for the gain factor therefore corresponds to
65535dec (0x00010000hex) and is limited to 0x7FFFF.
First limit value for setting the status bits
Second limit value for setting the status bits
BOOLEAN
INT16
INT32
INT16
INT16
RW
RW
RW
RW
RW
User calibration offset
User calibration gain
User calibration offset
User calibration gain
INT16
INT16
RW
RW
Default
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x01 (1dec)
0x00 (0dec)
0x0000 (0dec)
0x00010000
(65536dec)
0x0000 (0dec)
0x0000 (0dec)
0x0000 (0dec)
0x4000
(16384dec)
42 - Object Descriptions IOLB-7014 User Guide : 2000645 Rev. A
IOLB-7014 Parameters
Index Subindex
2064
2064
2064
2064
2064
2064
2064
2064
2064
2064
2064
2064
2064
2064
2064
2064
01
02
05
07
08
10
11
14
17
18
19
20
23
24
Name Meaning Data type Flags
ANALOG INPUT CHANNEL 2 SETTINGS
Enable user scale 1 User scale is enabled BOOLEAN RW
Presentation
0
1
Signed presentation
Unsigned presentation
BIT3 RW
Siemens bits
2
1
Absolute value with
MSB as sign
Status displays are superimposed on the lowest three bits in the status word.
BOOLEAN RW
Enable limit 1
Enable limit 2
Enable user calibration
Enable vendor calibration
1
1
1
1
Enable Limit 1
Enable Limit 2
User calibration is enabled
Vendor calibration is enabled
BOOLEAN RW
BOOLEAN RW
BOOLEAN
BOOLEAN
RW
RW
Swap limit bits
User scale offset
User scale gain
Limit 1
Limit 2
1
Swaps the two limit-bits to be compatible to older hardware versions.
User scale offset
The gain is represented in fixed- point format, with the factor 2-
16. A value of 1 for the gain factor therefore corresponds to
65535dec (0x00010000hex) and is limited to 0x7FFFF.
First limit value for setting the sta- tus bits
Second limit value for setting the status bits
BOOLEAN
INT16
INT32
INT16
INT16
RW
RW
RW
RW
RW
User calibration offset
User calibration gain
User calibration offset
User calibration gain
INT16
INT16
RW
RW
Default
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x01 (1dec)
0x00 (0dec)
0x0000 (0dec)
0x00010000
(65536dec)
0x0000 (0dec)
0x0000 (0dec)
0x0000 (0dec)
0x4000
(16384dec)
IOLB-7014 User Guide : 2000645 Rev. A Object Descriptions - 43
IOLB-7014 Parameters
Index Subindex
2080
2080
2080
2080
2080
2080
2080
2080
2080
2080
2080
2080
2080
2080
2080
2080
01
02
05
07
08
10
11
14
17
18
19
20
23
24
Name Meaning Data type Flags
ANALOG INPUT CHANNEL 3
Enable user scale 1 User scale is enabled
0
1
Presentation
Signed presentation
Unsigned presentation
Siemens bits
2
1
Absolute value with
MSB as sign
Status displays are superimposed on the lowest three bits in the status word.
Enable limit 1
Enable limit 2
Enable user calibration
Enable vendor calibration
1
1
1
1
Enable Limit 1
Enable Limit 2
User calibration is enabled
Vendor calibration is enabled
Swap limit bits
User scale offset
User scale gain
Limit 1
Limit 2
1
Swaps the two limit-bits to be compatible to older hardware versions.
User scale offset
The gain is represented in fixed- point format, with the factor 2-
16. A value of 1 for the gain factor therefore corresponds to
65535dec (0x00010000hex) and is limited to 0x7FFFF.
First limit value for setting the status bits
Second limit value for setting the status bits
User calibration offset
User calibration gain
User calibration offset
User calibration gain
BOOLEAN RW
BIT3 RW
BOOLEAN RW
BOOLEAN RW
BOOLEAN RW
BOOLEAN RW
BOOLEAN RW
BOOLEAN RW
INT16
INT32
INT16
INT16
INT16
INT16
RW
RW
RW
RW
RW
RW
Default
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x01 (1dec)
0x00 (0dec)
0x0000 (0dec)
0x00010000
(65536dec)
0x0000 (0dec)
0x0000 (0dec)
0x0000 (0dec)
0x4000
(16384dec)
44 - Object Descriptions IOLB-7014 User Guide : 2000645 Rev. A
IOLB-7014 Parameters
Index Subindex
2096
2096
2096
2096
2096
2096
2096
2096
2096
2096
2096
2096
2096
2096
2096
2096
2096
01
02
05
06
07
08
10
11
14
17
18
19
20
23
24
Name Meaning Data type Flags
ANALOG INPUT CHANNEL 4 SETTINGS
Enable user scale 1 User scale is enabled BOOLEAN RW
Presentation
0
1
Signed presentation
Unsigned presentation
BIT3 RW
Siemens bits
2
1
Absolute value with
MSB as sign
Status displays are superimposed on the lowest three bits in the status word.
BOOLEAN RW
Enable filter
Enable limit 1
Enable limit 2
Enable user calibration
Enable vendor calibration
Swap limit bits
User scale offset
User scale gain
Limit 1
Limit 2
1
1
1
1
1
1
Filter enabled, the cyclesynchronous data exchange is not applied
Enable Limit 1
Enable Limit 2
User calibration is enabled
Vendor calibration is enabled
Swaps the two limit-bits to be compatible to older hardware versions.
User scale offset
The gain is represented in fixed- point format, with the factor 2-
16. A value of 1 for the gain factor therefore corresponds to
65535dec (0x00010000hex) and is limited to 0x7FFFF.
First limit value for setting the status bits
Second limit value for setting the status bits
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
INT16
INT32
INT16
INT16
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
User calibration offset
User calibration gain
User calibration offset
User calibration gain
INT16
INT16
RW
RW
Default
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x01 (1dec)
0x00 (0dec)
0x00 (0dec)
0x00 (0dec)
0x01 (1dec)
0x00 (0dec)
0x0000 (0dec)
0x00010000
(65536dec)
0x0000 (0dec)
0x0000 (0dec)
0x0000 (0dec)
0x4000
(16384dec)
IOLB-7014 User Guide : 2000645 Rev. A Object Descriptions - 45
IOLB-7014 Parameters
Index Subindex Name Meaning Data type Flags Default
FILTER SETTINGS - ALL CHANNELS (See
Filters (Common to All Input Channels) on Page 30 for more
information)
2048 06 Enable filter 1
Filter enabled, the cyclesynchronous data exchange is not applied
BOOLEAN RW 0x00 (0dec)
2048: 21 Filter settings
2
3
0
1
This object defines the digital filter settings of all the modules channels, if it is activated with index 2048:06.
The possible settings are numbered consecutively.
50 Hz FIR
60 Hz FIR
IIR 1
IIR 2
8
9
4 IIR 3
5IIR 1 IIR 4
6IIR 1 IIR 5
7 IIR 6
IIR 7
IIR 8
MISCELLANEOUS SETTINGS
UINT16 RW 0x0000 (0dec)
2
12 02
Standard
Command
Data Storage Lock
130 - Restore factory defaults UINT8 WO
BOOLEAN RW
0x0000 (0dec)
0x0000 (0dec)
46 - Object Descriptions IOLB-7014 User Guide : 2000645 Rev. A
Observation Parameters
Observation Parameters
Index Subindex
2078
2079
2079
2079
2079
2079
2079
2062
2063
2063
2063
2063
2063
2063
01
01
02
03
04
05
06
01
01
02
03
04
05
06
ADC raw value
R0 offset
R0 gain
R1 offset
R1 gain
R2 offset
R2 gain
ADC raw value
R0 offset
R0 gain
R1 offset
R1 gain
R2 offset
R2 gain
Name Meaning Data type Flags
ANALOG INPUT CHANNEL 1
Raw value of the analog/digital converter offset (vendor calibration)
INT16
INT16
RO
RW gain (vendor calibration) offset (vendor calibration) gain (vendor calibration) offset (vendor calibration) gain (vendor calibration)
INT16
INT16
INT16
INT16
INT16
RW
RW
RW
RW
RW
Default
0x0000 (0dec)
0x0000 (0dec)
0x4000
(16384dec)
0x0000 (0dec)
0x4000
(16384dec)
0x0000 (0dec)
0x4000
(16384dec)
ANALOG INPUT CHANNEL 2
Raw value of the analog/digital converter offset (vendor calibration)
INT16
INT16
RO
RW
0x0000 (0dec) gain (vendor calibration) offset (vendor calibration) gain (vendor calibration) offset (vendor calibration) gain (vendor calibration)
INT16
INT16
INT16
INT16
INT16
RW
RW
RW
RW
RW
0x0000 (0dec)
0x4000
(16384dec)
0x0000 (0dec)
0x4000
(16384dec)
0x0000 (0dec)
0x4000
(16384dec)
IOLB-7014 User Guide : 2000645 Rev. A Object Descriptions - 47
Observation Parameters
Index Subindex
2110
2111
2111
2111
2111
2111
2111
2094
2095
2095
2095
2095
2095
2095
01
01
02
03
04
05
06
01
01
02
03
04
05
06
ADC raw value
R0 offset
R0 gain
R1 offset
R1 gain
R2 offset
R2 gain
ADC raw value
R0 offset
R0 gain
R1 offset
R1 gain
R2 offset
R2 gain
Name Meaning Data type Flags
ANALOG INPUT CHANNEL 3
Raw value of the analog/digital converter offset (vendor calibration)
INT16
INT16
RO
RW gain (vendor calibration) offset (vendor calibration) gain (vendor calibration) offset (vendor calibration) gain (vendor calibration)
INT16
INT16
INT16
INT16
INT16
RW
RW
RW
RW
RW
Default
0x0000 (0dec)
0x0000 (0dec)
0x4000
(16384dec)
0x0000 (0dec)
0x4000
(16384dec)
0x0000 (0dec)
0x4000
(16384dec)
ANALOG INPUT CHANNEL 4
Raw value of the analog/digital converter offset (vendor calibration)
INT16
INT16
RO
RW
0x0000 (0dec) gain (vendor calibration) offset (vendor calibration) gain (vendor calibration) offset (vendor calibration) gain (vendor calibration)
INT16
INT16
INT16
INT16
INT16
RW
RW
RW
RW
RW
0x0000 (0dec)
0x4000
(16384dec)
0x0000 (0dec)
0x4000
(16384dec)
0x0000 (0dec)
0x4000
(16384dec)
48 - Object Descriptions IOLB-7014 User Guide : 2000645 Rev. A