Atdec AF-AT Installation Manual


Add to my manuals
4 Pages

advertisement

Atdec AF-AT Installation Manual | Manualzz
Installation Guide
AF-AT
Single Arm
Desktop Monitor Mount
COMPONENT CHECKLIST
A
VESA
head
(x1)
D
Rotation
limiter
(x1)
B
Monitor
arm
(x1)
H
Screw
M8 x 60mm
(x1)
C
Pole Assembly
(x1)
N
Pole
top cap
(x1)
E
Primary arm
cable cover
(x1)
I
J
Screw
Security Screw
M8 x 30mm
M4 x 16mm
(x1)
(x1)
O
Bolt through
base
(x1)
P
5mm
Allen key
(x1)
Q
Mounting
screws
M4 x 10mm
(x4)
F
Secondary arm
cable cover
(x1)
K
Steel
washer
(x1)
G
Desk clamp
assembly
(x1)
L
Cable
stop
(x2)
R
Mounting
screws
M4 x 12mm
(x4)
M
Cable
clip
(x1)
S
Mounting
screws
M4 x 16mm
(x4)
REQUIRED TOOLS
• Phillips Head Screwdriver
WEIGHT RANGE
Flat Monitors
0 - 8kg
(0 - 17.6lbs)
Curved Monitors
0 - 5.5kg
(0 - 12lbs)
IMPORTANT INFORMATION
! Please ensure this product is installed as per these installation instructions.
! This product is compatible with the range of AF Poles and arms.
! The manufacturer accepts no responsibility for incorrect installation.
! Curved monitors, deep devices (such as all-in-one PCs) and offset VESA locations exert additional leverage that can exceed the
capacity of the mount even though the monitor weight may be within the stated range. Please contact Atdec if you would like further
information.
AF-AT Page 1 of 4
1. Desk overview
Desk Clamp
The desk clamp bracket
can be repositioned to
suit different mounting
surface thicknesses.
Default
Inverted
52mm
(2.1”)
88mm
(3.5”)
140mm
(5.5”)
55mm
(2.2”)
MIN THICKNESS - 0mm (0”)
MAX THICKNESS - 39mm (1.5”)
MIN THICKNESS - 35mm (1.4”)
MAX THICKNESS - 76mm (3”)
2. How to reconfigure desk clamp
2.1 Remove screws
(M8 x 16mm Countersunk screw)
2.2 Remove clamp plate
2.3 Invert bracket
2.4 Replace clamp plate
2.5 Reattach bracket
3. Post mount configuration
3.1 Attach clamp to post
3.2 Place in desired location
3.3 Screw pressure plates in and tighten firmly.
Pressure Plate
M8 x 30mm
Countersunk
screw Tighten
firmly
M10 Desk Clamp Screw
5mm Allen Key
4. Bolt through - Drill Hole
5. Bolt Pole to work surface
4.1 Drill 9mm hole in
desired post position
on work surface.
9mm
(3/8”)
M8x60mm
Screw
25
of mm
fse
t
5mm
Allen Key
Bolt
Through
Plate
Note orientation of
plate with pole
AF-AT Page 2 of 4
6. Install VESA monitor head
6.1 Install VESA monitor head as shown.
100mm
75mm
Screen
VESA monitor
head
M4x10/12/16mm
Phillips Head Mounting
Screws
100mm
75mm
7. Install arm assembly
7.1 Unlock handgrip and raise so
that handgrip tab protrudes
Handgrip Tab
7.2 OPTIONAL ROTATION LIMITER
Insert rotation limiter for 180�
rotation around mounting pole
7.3 Slip the Arm Assembly
over the Handgrip Tab and
then onto the Pole
Arm Assembly
7.4 Slide the Arm Assembly and
Handgrip down the pole before locking
the handgrip at the desired height
7.5 Insert Pole Top
Cap into Pole. This is
also where the Allen
Key is stored.
5mm
Allen Key
Pole
Top Cap
8. Mounting Monitor
8.1 Insert VESA monitor head into
the receptacle in the Arm Assembly
8.2 OPTIONAL SECURITY SCREW
Ensure the Monitor is supported, then loosen the Monitor head
screw with the 5mm Allen Key and tilt screen up before installing
the M4 x 16mm Security Screw into the Security Screw hole
Monitor head
screw
Note: Support Screen
when adjusting tilt.
VESA monitor head
Security Screw
Hole
Loosen
Tighten
Arm Assembly
M4 x 16mm
Security Screw
Phillips Head
Screwdriver
5mm Allen Key
AF-AT Page 3 of 4
9. Adjusting Height
9.1 Unlock Handgrip ensuring both the
screen and arm assembly are supported
9.2 Lift/Lower the Screen to the desired
height. Move both Screen and Arm
assembly together
9.3 Lock Handgrip firmly
10. Cable Management
10.1 After plugging in your cables,
install the Cable Covers.
10.2 Push Cable Covers away from
Elbow Joint to secure in place.
10.3 Cable Clips and Cable Stops can be installed
to further manage cables.
Cable
Stop
Lock Slot
Lock Slot
Insert Cable Covers
up intoLock Slots.
‘click’
‘click’
Note: Ensure enough cable
slack is given to allow for
movement.
‘click’
Elbow Joint
Cable
Clip
‘click’
Elbow Joint
11. Insert Cable Stops
11.1 Insert Cable Stop on one edge
of the Pole Slot
Note: Press down firmly onto
the other edge of the Cable
Stop and hold. This allows the
rear profile to flex in place
11.2 Insert allen key into top cap
on pole
Allen Key
Storage
12. Adjusting the Display Bracket
Portrait/ Landscape
Tilt (Screen angle up/down)
Pan (Screen angle left/right)
VESA 75 x 75 / 100 x 100mm
100mm
75mm
Loosen
100mm
75mm
5mm Allen Key
Tighten
No Allen Key
necessary
Note: Support Screen when
adjusting tilt.
No Allen Key necessary
No portion of this document or any artwork contained herein should be reproduced in any way without
the express written consent of Atdec Pty Ltd. Due to continuing product development, the manufacturer
reserves the right to alter specifications without notice. ©20191024A
atdec.com | atdec.co.uk | atdec.com.au
AF-AT Page 4 of 4

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement