Advertisement
Advertisement
Federal Communications Commission Radio Frequency
Interference Statement
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. However, if this equipment does cause interference to radio or television equipment reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
■
■
Reorient or relocate the receiving antenna.
Increase the separation between equipment and receiver.
■
■
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/television technician for help.
Use a shielded and properly grounded I/O cable and power cable to ensure compliance of this unit to the specified limits of the rules.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
Adaptec, Inc.
AVA-1505AE/AI
Tested to Comply With
FCC Standards
FOR HOME AND OFFICE USE
Canadian Compliance Statement
This Class B digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du
Règlement sur le matérial brouilleur du Canada.
Adaptec, Inc.
691 South Milpitas Blvd.
Milpitas, CA 95035
Copyright 1997, Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of Adaptec, Inc., 691 South
Milpitas Blvd., Milpitas, CA 95035.
Adaptec, the Adaptec logo, AVA, EZ-SCSI, and SCSISelect are trademarks of Adaptec, Inc. which may be registered in some jurisdictions.
Windows NT is a trademark, and Windows and Windows 95 are registered trademarks of Microsoft Corporation in the U.S. and other countries used under license. All other trademarks used are owned by their respective owners.
The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, Adaptec, Inc. assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein.
Printed in Singapore
Stock No.: 511351-00, Rev. B MR 2/97
Installation
Guide
AVA-1505AE/AI
External and Internal
ISA-to-SCSI-2 Host Adapters
Simple, complete PC connection to a
single non-bootable external or internal
SCSI-2 peripheral
Introduction
This installation guide explains how to install and use your new
SCSI host adapter. You can use the AVA
™
-1505AE to connect a single external device to your system, or use the AVA-1505AI to connect a single internal device.
Once you have performed the simple installation steps listed on pages 2 and 3, your host adapter and SCSI device are ready for operation.
We recommend that you keep this installation guide with your important computer documents.
This installation guide includes information on the Adaptec
SCSISelect
configuration utility. After installation, you can use this utility to reconfigure most of your host adapter settings without having to reopen the computer or handle the card.
J3
Contents
Installation and Setup
Installation Steps .........................2 - 3
Helpful Hints
Using Your Host Adapter .............. 4
Setting Host Adapter Jumpers ...... 4
SCSISelect Utility
Configuring the Host Adapter ...... 5
Starting the SCSISelect
Utility ................................................. 5
SCSISelect Settings............................ 6
Need Assistance?
Troubleshooting Checklist ............. 7
Common Problems and Solutions 7
J3
AVA-1505AE
(external connector)
Pin 1
AVA-1505AI
(internal connector)
1
Installation and Setup
Step 3:
Insert the host adapter in the slot; press down firmly so that the bus contacts are securely seated in the slot. If you are installing the
AVA-1505AE secure it with the screw you removed in Step 2.
WARNING: Turn OFF power to the computer and disconnect the power cord.
Step 1:
Remove the cover from the computer case.
(Refer to the instructions in your computer documentation.)
Step 2:
Locate an unused 16-bit ISA expansion slot (this slot is typically black). If you are installing the AVA-1505AE, unscrew and remove the expansion slot bracket that covers the card-slot opening. If you are installing the AVA-1505AI, it is not necessary to remove the expansion slot bracket.
Step 4:
Prepare the SCSI device for installation.
The host adapter is already terminated.
■
Make sure the SCSI device is assigned a unique SCSI ID from 0 to 6. Refer to the device’s documentation for instructions on setting the SCSI ID.
■
Install (or enable) terminators on the device.
On most external SCSI devices, termination is controlled by installing or removing a terminating plug (see Step 5). Refer to the device’s documentation to determine how to enable or disable termination on your particular device.
16-bit ISA
Expansion Slots
(typically black)
2
Step 5:
Install the SCSI device.
■ If you are installing an internal device with the AVA-1505AI, plug one end of the internal 50-pin flat ribbon cable into the host adapter’s 50-pin connector, and the other end of the ribbon cable into the 50-pin connector on the internal SCSI device. Be sure to maintain Pin-1 orientation. Terminate the device.
Pin 1
■
If you are installing an external device with the AVA-1505AE, plug one end of the external DB25 SCSI cable into the host adapter’s external DB25 SCSI connector, and the other end of the cable into a free SCSI connector on the external SCSI device, and install a terminator plug.
Terminator
Plug
Step 6:
Connect the SCSI device to a power source.
■
If installing an internal device, connect a
DC power cable from your computer’s
■ power supply to the power connector on the SCSI device.
If installing an external device, connect the power cable.
Step 7:
Replace the computer cover and turn ON your computer.
■
■
■
Step 8:
Install the appropriate host adapter software driver for your operating system:
DOS and Windows
®
3.x: Because drivers for DOS and Windows 3.x are not embedded in the operating system, you must load them yourself. If your host adapter came bundled with Adaptec EZ-SCSI
®
software, see the EZ-SCSI software documentation for installation instructions. Contact your distributor if you wish to purchase EZ-SCSI.
If you purchased your host adapter as part of a bundle created by a third party, you can use the drivers they provide. Please refer to the documentation provided by the third party or contact them directly for installation instructions.
Windows
®
95: Windows 95 has embedded driver support for your host adapter. When you start
Windows 95, the host adapter is detected and the appropriate driver is automatically installed. To take advantage of various productivity tools and accessories, you should also install Adaptec EZ-SCSI software. See the EZ-SCSI software documentation for installation instructions.
OS/2, and Windows NT™: The most current versions of these operating systems have embedded driver support for your host adapter as part of their installation software. For instructions on installing embedded driver support, see the operating system documentation.
Congratulations!
Installation of your host adapter is complete. For useful information on using your host adapter, refer to Helpful Hints on page 4. For instructions on using the SCSISelect configuration utility, refer to SCSISelect Utility on page 5. If you need further help, refer to Need Assis-
tance? on page 7.
3
Helpful Hints
Using Your Host Adapter
Now that your host adapter is installed, read this section for useful tips and information on using your host adapter.
■
■
■
You may need to install the manufacturer’s proprietary device drivers if you use SCSI devices other than hard disk drives and CD-ROM drives. (See your device’s documentation.)
Be sure to use a high-quality SCSI cable to connect the device to the host adapter. This ensures reliable data transfer.
Your host adapter can support the SCSI Configured
AutoMatically (SCAM) protocol, which assigns SCSI
IDs dynamically and resolves SCSI ID conflicts automatically at bootup. To enable or disable SCAM support, see Advanced Host Adapter Settings on page 6. If
SCAM is enabled, and your SCSI device or hard disk drive supports SCAM, you do not need to set SCSI IDs manually. Most SCSI devices currently in use, however, do not support SCAM and must have the SCSI ID set manually.
SCSI hard disk drives
■
SCSI hard disk drives are physically formatted at the factory and should not need to be low-level formatted again. Low-level formatting should only be necessary if the hard disk drive is corrupted. See Using
the SCSI Disk Utilities on page 5 for more information.
If you connect a new hard disk drive to your host adapter, you must partition and logically format the drive. For DOS and Windows 3.x, use the afdisk command in the c:\scsi directory if you have EZ-SCSI. If you do not have EZ-SCSI, read your system documentation and/or contact your distributor for more information. For Windows 95, make sure that Int13 is selected (see your Windows 95 documentation), then reboot and use the fdisk and format commands in a
Windows 95 DOS session. For other operating systems, see your operating system documentation.
■ Because the host adapter does not have a BIOS, the computer cannot boot from a SCSI hard disk drive connected to the host adapter.
4
Multiple Host Adapters
■
■
Multiple SCSI host adapters can be installed in your computer; you are limited only by the available system resources (e.g., I/O port and IRQ channel).
Each host adapter you install forms a separate SCSI bus with a different set of SCSI devices. SCSI IDs can be reused as long as the ID is assigned to a device on a different host adapter (e.g., each host adapter can have a device with SCSI ID 0).
Setting Host Adapter Jumpers
There is one jumper on your AVA-1505AE/AI host adapter. Jumper J3 controls the I/O Port Address. You do not need to change the J3 Jumper setting in Plug and
Play systems.
If you have a non-Plug and Play system, you may need to change the I/O address if it conflicts with another device installed in your system. To change the I/0
Address, remove the shunt from Jumper J3.
Settings
I/O Port Address—340h
I/O Port Address—140h
J3
Off
On
SCSISelect Utility
Configuring the Host Adapter
The SCSISelect configuration utility allows you to change host adapter and SCSI settings without having to open the computer or handle the board. If, however, you have an I/
O Port Address conflict, you must change the setting on the board, as described in Setting Host Adapter Jumpers on page 4. SCSISelect also contains utilities that allow you to low-level format or verify the disk media of your SCSI hard disk drive.
The SCSISelect settings are listed in the table below. If you want to view and/or change the current settings, or if you would like to low-level format or verify a disk, see Starting
the SCSISelect Utility on this page. Detailed descriptions of each setting begin on page 6.
Basic Host Adapter Settings
Host Adapter Interrupt (IRQ) Channel
Host Adapter DMA Channel
Host Adapter SCSI ID
SCSI Parity Checking
SCSI Device Settings
Initiate Sync Negotiation
Enable Disconnection
Advanced Host Adapter Settings
ISA Plug and Play Mode
Plug and Play SCAM Support
Starting the SCSISelect Utility
SCSISelect is provided on a bootable diskette. To run, simply insert the diskette in a bootable floppy drive and boot your system. Save this diskette. You may need to run SCSISelect in the future.
Note: The SCSISelect utility is an executable file named 1505acfg.exe
on the diskette. If you cannot boot from this diskette for whatever reason, but you can run DOS on your system, you can run SCSISelect by running this file under DOS.
The first menu that appears displays the options
Configure/View Host Adapter Settings and SCSI Disk
Utilities.
Adaptec AVA-1505 AE/AI SCSISelect(TM) Utility v1.00
AVA-1505AE/AI at Port 0140h
Would you like to configure the host adapter or run the
SCSI disk utilities? Select the option and press <Enter>.
Press <F5> to switch between color and monochrome modes.
Options
Configure/View Host Adapter Settings
SCSI Disk Utilities
Arrow keys to move cursor, <Enter> to select option, <Esc> to exit (*=default)
Using SCSISelect Menus
SCSISelect uses menus to list options you can select. To select an option, use the
↑ and
↓
keys to move the cursor to the option, then press Enter.
In some cases, selecting an option displays another menu. You can return to the previous menu at any time by pressing Esc. To restore the original SCSISelect default values, press F6. To toggle the display between color and monochrome modes, press F5 (this feature may not work on all monitors).
Exiting SCSISelect
To exit SCSISelect, press Esc until a message prompts you to exit (if you changed any host adapter settings, you are prompted to save the changes before you exit). At the prompt, select Yes to exit, then press any key to reboot the computer. Any changes you made in SCSISelect take effect after the computer boots. (Be sure to eject the diskette before you re-boot.)
Using the SCSI Disk Utilities
To access the SCSI disk utilities, select the SCSI Disk
Utilities option from the menu that appears after starting
SCSISelect. Once the option is selected, SCSISelect immediately scans the SCSI bus (to determine the device installed) and displays a list of the SCSI IDs of the host adapter and installed device.
When you select a specific ID and device, a small menu appears, displaying the options Format Disk and Verify
Disk Media.
5
■ Format Disk —Most SCSI disk devices are preformatted at the factory and do not need to be formatted again. If your hard disk drive becomes corrupted, you can use this utility to low-level format the hard disk drive. A hard disk drive must be low-level formatted before you can use your operating system’s partitioning and file preparation commands, such as
Adaptec’s afdisk and format .
The Adaptec Format Disk utility is compatible with the vast majority of SCSI hard disk drives.
Caution: A low-level format destroys all data on the drive. Be sure to back up your data before performing this operation. You cannot abort a low-level format once it is started.
■
Verify Disk Media —This utility allows you to scan the media of a hard disk drive for defects. If the utility finds bad blocks on the media, it prompts you to reassign them; if you select Yes, those blocks are no longer used. You can press Esc at any time to abort the utility.
SCSISelect Settings
Basic Host Adapter Settings
The following settings are the SCSISelect settings most likely to require any modification:
■ Host Adapter Interrupt (IRQ) Channel —This option sets the host adapter’s IRQ. Each add-in card installed in your system, including the host adapter, must have a unique IRQ. In Plug and Play systems, the IRQ is set automatically. In non-Plug and Play systems you must set the IRQ manually.
■
■
■
Host Adapter DMA Channel —This option sets the host adapter’s Direct Memory Access (DMA) channel.
Host Adapter SCSI ID — This option sets the host adapter’s SCSI ID. We recommend that you leave the host adapter set to SCSI ID 7, which gives the host adapter the highest priority on the SCSI bus.
SCSI Parity Checking —This option determines whether the host adapter verifies the accuracy of data transfer on the SCSI bus. Most SCSI devices do support SCSI parity. If you are not sure whether a device supports SCSI parity, consult the documentation for the device.
SCSI Device Settings
The SCSI device settings allow you to configure certain parameters for your SCSI device. To configure settings for a specific device, you must know the SCSI ID assigned to that device. If you are not sure of the SCSI ID, see Using
the SCSI Disk Utilities on page 5.
■
■
Initiate Sync Negotiation —This option determines whether synchronous data transfer negotiation (Sync
Negotiation) between the device and host adapter is initiated by the host adapter. In many applications, enabling synchronous negotiations improves performance.
Enable Disconnection —This option determines whether the host adapter allows the SCSI device to disconnect from the SCSI bus (sometimes called
Disconnect/Reconnect). With only one device on the
SCSI bus, disabling disconnection will give a slight performance increase.
Advanced Host Adapter Settings
The advanced host adapter settings should not be changed unless absolutely necessary.
■
■
ISA Plug and Play Mode —This option determines whether the host adapter supports Plug and Play functionality. When Plug and Play Support is enabled, the host adapter will work fine in both Plug and Play and Legacy (non-Plug and Play) systems.
The only time you should disable Plug and Play Support is when you have an “ill-behaved” Plug and
Play system. If you cannot get your host adapter working in a Plug and Play system, as a last resort, try disabling this setting.
Plug and Play SCAM Support —This option determines whether the host adapter automatically assigns
SCSI IDs to SCSI devices that support the SCAM protocol (see Using Your Host Adapter on page 4). You should disable this option if you have a non-SCAM device.
6
Need Assistance?
Troubleshooting Checklist
Most problems that occur with your host adapter result from errors in preparing and connecting devices on the
SCSI bus. If you have problems when using your host adapter, check these items first.
■
■
Is the SCSI device powered?
Are all the power cables and SCSI bus cable connected?
■
■
■
■
Is the host adapter firmly seated and secured in an expansion slot?
Is the device single-ended (as opposed to differential)?
Do the host adapter and the device on the SCSI bus have unique SCSI IDs? (See Step 4 on page 2)
Is the SCSI device terminated properly? (See Step 4 on page 2)
■
Is parity checking consistently enabled or disabled on both the device and the host adapter? (See Basic Host
Adapter Settings on page 6.)
If you still have problems after checking the above items, continue with the following sections.
Common Problems and Solutions
When installing EZ-SCSI, my DOS/Windows 3.x system does not find the AVA-1505AE/AI.
This indicates a resource conflict. Try a different I/O Port
Address and/or IRQ and try installing EZ-SCSI again.
I have both a Soundblaster card with a SCSI controller embedded on it, and an AVA-1505AE/AI installed in the same computer. Am I going to experience any resource conflicts?
The SCSI controller on the Soundblaster card is typically set, by default, to use I/O port address 340 and IRQ 11.
To avoid resource conflicts, check the current setting of the AVA-1505AE/AI and make any required changes with the J3 jumper and SCSISelect.
When trying to run the Format/Verify SCSI disk utility in SCSISelect, I get an Unexpected SCSI Command Failure pop-up box with error information.
The utility probably encountered a problem with the disk device or the media and therefore cannot run. You can determine from the Sense Key information (e.g., 06h -
Unit Attention) both the cause of the problem and its solution. Here are some of the more common Sense Key values and their meanings:
■
02h - Not ready —The media is not ready to format.
Be sure that media is inserted in the drive and that the media is spun up.
■
■
03h - Medium error —The disk media may be defective. If it is a removable-media drive, try using a different disk media. If it is a fixed hard disk drive, the disk may be physically damaged. Verify the hard disk drive to check for damage. If there is damage, format the media with SCSISelect.
04h - Hardware error —The hard disk drive may be defective. Consult the hardware documentation and contact the manufacturer.
■
■
05h - Illegal request —The Adaptec formatting utility does not support a low-level format of this device; however, the device may already be low-level formatted by the manufacturer. (This error rarely occurs.)
06h - Unit attention —The removable media may be write-protected. Disable write protection and run the utility again.
I have some older SCSI-1 devices installed and my computer is operating erratically or hangs.
Try changing the following SCSI device setting in
SCSISelect for your older SCSI-1 device: Set Initiate Sync
Negotiation to No.
The screen is difficult to read when I run the SCSISelect utility.
Press F5 to toggle the display between color and monochrome modes. This may make it easier for you to read the screen.
I cannot use my host adapter in a non-Plug and Play system.
Check for possible resource conflicts between the host adapter and other cards installed in your computer; the cards may have conflicting I/O port address and IRQ settings. Try changing these settings on the host adapter one at a time, with Jumper 3 and SCSISelect to isolate the conflict.
I cannot use my host adapter in a Plug and Play System
Try setting ISA Plug and Play Mode to Disable in the
Advanced Configuration Options of SCSISelect. Your host adapter is now a Legacy card, and you must configure it manually with the Jumper J3 and SCSISelect.
❒