Aiphone JM-DVF-L Installation Manual

Add to My manuals
8 Pages

advertisement

Aiphone JM-DVF-L Installation Manual | Manualzz

JM-DVF-L

VIDEO DOOR STATION (GUIDANCE-ENABLED TYPE)

INSTALLATION MANUAL

FK1876 A P1112OZ

Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation, and keep it in a safe place for future reference.

Please note that the illustrations in this manual may differ from the actual product.

CONTENTS

PRECAUTIONS ................................ 2

WARNING ........................................... 2

CAUTION ............................................ 2

GENERAL PRECAUTIONS ............... 2

NOTICES ............................................ 2

PACKAGE CONTENTS ................... 3

PART NAMES ................................. 3

CONNECTIONS ............................... 4

MOUNTING ..................................... 5

Mounting locations ........................... 5

Mounting positions and image view area ............................................ 5

Mounting ............................................ 6

TECHNICAL DATA AND

PRECAUTIONS ................................

6

WARRANTY .....................................

7

2

PRECAUTIONS

Prohibited Do not dismantle unit Keep unit away from water General precautions

WARNING

Negligence could result in death or serious injury.

1. Do not dismantle or alter the unit. Fire or electric shock could result.

2. The unit must be installed and wired by a quali fi ed technician.

CAUTION

Negligence could result in injury to people or damage to property.

1. Do not install or make any wire terminations while power supply is plugged in. It can cause electrical shock or damage to the unit.

2. When mounting the unit on a wall, install the unit in a convenient location, but not where it could be jarred or bumped. Injury could result.

3. Before turning on power, make sure wires are not crossed or shorted. Fire or electric shock could result.

4. Do not install the unit in any of the following locations. Fire, electric shock, or unit trouble could result.

* Places under direct sunlight or near heating equipment that varies in temperature.

*

*

*

*

*

Places subject to dust, oil, chemicals, hydrogen sul fi de (hot spring).

Places subject to moisture and humidity extremes, such as bathrooms, cellars, greenhouses, etc.

Places where the temperature is low, such as inside a refrigerated area or in front of an air conditioner.

Places subject to steam or smoke (near heating or cooking surfaces).

Where noise generating devices such as dimmer switches or inverter electrical appliances are closeby.

GENERAL PRECAUTIONS

1. Keep the unit more than 1 m (3.3') away from radio or TV sets.

2. Keep the intercom wires more than 30cm (12'') away from AC

100-240V wiring. AC induced noise and/or unit malfunction could result.

3. The unit will not work during power failure.

4. Door station is weather-resistant, but do not spray with highpressure water. Unit trouble could result.

5. When outside temperature lowers sharply after rainfall, etc., the inside of the camera may fog up slightly, causing a blurry image, but this is not a malfunction. Normal operation will be restored when moisture evaporates.

6. Environmental sound around the unit may hinder smooth communication, but this is not a malfunction.

NOTICES

We will under no conditions be liable for damage occurring due to the inability to communicate due to malfunctions, problems, or operational errors in this product.

This manual was created by Aiphone Co., Ltd., all rights reserved.

Copying, in part or in whole, this manual without prior permission from Aiphone Co,. Ltd. is strictly forbidden.

Please note that images and illustrations depicted in this manual may differ from the actual ones.

Please note that this manual may be revised or changed without prior notice.

Please note that product speci fi cations may be changed for the sake of improvement without prior notice.

PACKAGE CONTENTS

Verify that the following parts are included.

The unit Flash mount back box Special screw x 4 Speial screwdriver

Transparent name plate x 2 Installation Manual

PART NAMES

White light LED

Lights up automatically when it gets dark around this station.

Blinks when this station is sounding an alarm.

These functions can be enabled or disabled by the setting on the master station.

Speaker

Outputs sounds from the master station or a sub master station.

Name plate (with backlight)

Write down a name on the plate. The backlight is always lit while the power is on to enable a visitor to con fi rm the name even at night.

Voice guidance

This station also sounds messages in the following states.

State Message

When a calling is started "Call in progress"

When talking becomes enabled "Please speak now"

When the door lock is released "Door open"

* The language for the messages depends on the language setting made on the master station.

Camera

Captures images to display on the screens of the master and sub master stations.

Microphone

Sends sounds from the door station to the master and sub master stations.

Call button

Calls the preset master and sub master stations.

Door release indicator (green)

Lights up while the door lock is released from the master station or a sub master station.

Talk indicator (orange)

Lights up while talking.

Call indicator (orange)

Lights up while calling.

3

CONNECTIONS

Notes on cables

Use PE (polyethylene)-insulated PVC jacket cable.

Parallel or jacketed 2-conductor, mid-capacitance, non-shielded cable is recommended.

Never use individual conductors, twisted pair cable, or coaxial cable.

Wiring distance

[A]

[B]

Ø0.65 mm

(22 AWG)

50 m (165')

Wire diameter

Ø0.8 mm

(20 AWG)

Ø1.0 mm

(18 AWG)

100 m (330') 100 m (330')

10 m (33')

Ø1.2 mm

(16 AWG)

100 m (330')

Connection diagram

Electric door strike *1

EL-12S etc.

Video door station

(guidance-enabled type)

JM-DVF-L

Master station

JM-4MED

[B]

[B]

PT

AC transformer

[B]

NC A1 A2

2

NP

[A]

1A1

1A2

Connect to the electric door strike according to its speci fi cations.

NOTES:

• Do not use the unused terminals for other purposes.

• In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be

• connected.

For connecting other manufacturers’ products, refer to the instruction manuals for those products.

The illustration of the unit’s rear panel differs from the actual product. This is to simplify the diagram.

Wires

Inlet * 2

Terminal cover

The terminals are inside the terminal cover. After connecting, route the wires through the wiring paths, then close the cover.

Be sure to route the wires through inlet.

When closing the terminal cover, close it until it clicks.

* 2 : Not available.

Do not connect a LAN connector, etc. to this port.

*1: Output speci fi cations

Output method

Voltage between terminals

N/O or N/C dry closure contact

24V AC, 0.5A (resistive load)

24V DC, 0.5A (resistive load)

Minimum overload (AC/DC):

100mV, 0.1mA

4

MOUNTING

Mounting locations

Do not install this station in any of the following locations where lighting or the ambient environment could impact the display on the screen of the master station or a sub master station due to the characteristics of this station's camera.

a Locations subject to direct sunlight b There is a white wall behind the caller c Other locations subject to strong lighting or backlighting conditions

Mounting positions and image view area

Wide image

Approx.

1,050 mm

(3' 5")

Zoom image

Wide image

Objects appear smaller due to greater distortion in the surrounding sections compared to the central section, but a wider area is displayed.

The display range is a rough estimation and may change due to the installation environment.

Approx. 700 mm (2' 3")

Mounting position

Approx. 2,100 mm (6' 11")

Approx. 1,050 mm (3' 5")

Approx. 1,050 mm (3' 5")

1,500 mm (5')

500 mm (20")

Unit center

1,500 mm (5')

Approx. 900 mm (3')

Approx. 170°

500 mm (20")

Mounting position

1,300 mm (4' 3")

Approx. 1,900 mm (6' 3")

Approx. 1,050 mm (3' 5")

Approx. 850 mm (2' 9")

500 mm (20")

Unit center

1,300 mm (4' 3")

An area over a range of approx. 170° in a 500 mm

(20") radius from the camera displays.

(The display range is a rough estimation and may change due to the installation environment.)

The zoom position can be changed. (Refer to the master station's "OPERATION MANUAL".)

The factory setting is "Center" for Zoom mode.

Zoom image (when mounting position is 1,500 mm (5'))

Up/Down

Zoom <Up>

Approx. 2,350 mm (7' 8")

Zoom <Center>

Approx. 1,900 mm (6' 3")

Approx. 850 mm (2' 9")

Approx. 1,500 mm (5')

Unit center

Approx. 700 mm (2' 3")

Approx. 1,200 mm (3' 11")

Unit center

1,500 mm (5')

500 mm

(20")

1,500 mm (5') 500 mm (20")

Left/Right

Zoom <Left> Zoom <Center>

500 mm (20") 500 mm (20")

Approx. 100 mm (4")

Approx. 1,300 mm (4' 3") Approx. 900 mm (3')

Zoom <Down>

500 mm (20")

Approx. 1,600 mm (5' 4")

Unit center

Approx. 850 mm (2' 9")

1,500 mm (5')

Approx. 750 mm (2' 5")

Zoom <Right>

500 mm (20")

Approx. 1,300 mm (4' 3")

Approx. 100 mm (4")

5

Mounting

Flush mount back box (included)

Vandal-resistant front panel with the unit attached

Special screw x 4 (included)

120 mm

(4-3/4'')

1 Install the back box in the wall, and then connect the wires to the unit with the terminal cover open.

3 Fasten the front panel to the back box with the special screws.

279 mm

(11'')

Special screwdriver

(included)

Loosen

Tighten

Transparent name plate

45 mm

(1-3/4'')

Mounting height (box center)

GL=1,500 mm (5')

2 Insert the transparent name plate.

1 Peel off the protective seals on the plate (both sides).

2 Fill in the name on the transparent name plate.

Be sure to leave 25 mm (1") of white space on the right end to account for insertion.

3 Insert the fi lled-in transparent name plate at the speci fi ed insertion opening (indicated with in diagram).

25 mm

(1")

To insertion opening

ABCDEFG

2 mm (1/8")

6

TECHNICAL DATA AND PRECAUTIONS

Technical data

Power supply

Operating temperature

Supplied from master station

- 10 - 60°C (+14°F - +140°F)

Dimensions

Weight

JM-DVF-L 150 (W) x 309 (H) x 30 (D) mm

5-15/16" (W) x 12-3/16" (H) x 1-3/16" (D)

Flush mount back box 120 (W) x 279 (H) x 45 (D) mm

4-3/4" (W) x 11" (H) x 1-3/4" (D)

JM-DVF-L Approx. 980g (2.16 lbs.)

Flush mount back box Approx. 670g (1.48 lbs.)

Technical precautions

• Cleaning: Clean units with a soft cloth and gentle cleaner. Do not spray cleaner directly on unit. Do not use an abrasive cleanser or cloth.

WARRANTY

Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the fi nal decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. This warranty is limited to the standard speci fi cations listed in the operation manual. This warranty does not cover any supplementary function of a third party product that is added by users or suppliers. Please note that any damage or other issues caused by failure of function or interconnection with Aiphone products is also not covered by this warranty. Aiphone will not be responsible for any costs incurred involving on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use, or for any consequent inconvenience or losses that may result.

The object area of is the EU.

FCC

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna

Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. Increase the separation between the equipment and receiver.

• Consult the dealer or an experienced radio/TV technician for help.

7

http://www.aiphone.net/

AIPHONE CO., LTD., NAGOYA, JAPAN

AIPHONE CORPORATION, BELLEVUE, WA, USA

AIPHONE S.A.S., LISSES-EVRY, FRANCE

Printed in Thailand

advertisement