Cellular Antenna Quick Start Guide

Agilent Technologies

8712ET/ES and 8714ET/ES

Agilent Part Number 08714-90022

Printed in USA June 2000

Supersedes October 1998

© Copyright 1998–2000 Agilent Technologies, Inc.

This quick start guide provides basic instructions on how to verify the performance of cellular antenna systems. Refer to the Option 100 Fault Location and Structural Return Loss Measurement User’s Guide

Supplement for more detailed information. Also, please refer to your analyzer’s User’s Guide for safety, warranty, and assistance information.

NOTE This quick start guide assumes the use of an 8712ET or 8714ET. If you are using an 8712ES or 8714ES, some key presses and displays will be slightly different.

To Make a Fault Location Measurement

1. Choose the measurement parameters or recall an instrument state.

PRESET BEGIN Cable Fault Location

Start Distance XX ENTER Stop Distance XX ENTER

2. Reduce the interference.

3. Calibrate the analyzer.

CAL Full Band Cal

BEGIN Cable Fault Location

Band Pass Center Frequency 900

MHz

FREQ Fault Loc Frequency

Band Pass Max Span 300 MHz

AVG System Bandwidth

Narrow 250 Hz

-1-

4. Connect the equipment.

5. Interpret the measurement / save results.

MARKER Marker Search Max Search

Mkr − > Max

Search

SAVE RECALL Define Save Data ON

Prior Menu Save State

If Measurement Results Were Poor

The following results indicate a specific problem you may encounter. Refer to your Option 100 User’s

Guide Supplement for more information.

Problem

The measured amplitude and distance of a 1000 ft. cable are wrong. (Cable is not terminated in this example.)

Solution

Change the “velocity factor” and “cable loss” values to the values specified by the cable manufacturer.

-2-

CAL Velocity Factor Cable Loss

To Make a Return Loss Measurement

1. Choose the measurement parameters or recall an instrument state.

PRESET MEAS 1 Reflection (or S11 ) AVG System Bandwidth Narrow 250 Hz

2. Calibrate the analyzer.

3. Connect the equipment.

CAL 1-Port (or User 1-Port )

4. Interpret the measurement / save results.

5. View SWR / save results.

MARKER Marker Search Min Search

Mkr − > Min

FORMAT SWR SCALE Scale/Div 0.2

ENTER

SAVE RECALL Define Save Data ON

Prior Menu Save State

-3-

SAVE RECALL Save State

To Make an Insertion Loss Measurement

1. Choose the measurement parameters or recall an instrument state.

PRESET MEAS 1 Reflection (or S11 ) AVG

System Bandwidth Narrow 250 Hz

2. Calibrate the analyzer.

3. Connect the equipment.

CAL 1-Port (or User 1-Port )

4. Interpret the measurement / save results.

5. Calculate insertion loss and end of cable.

MARKER 900 MHz

SAVE RECALL Define Save Data ON

Prior Menu Save State

Insertion Loss Calculation

= marker value ÷ 2

= 7.36 dB

÷

2 = 3.68 dB

End of Cable Calculation

=

λ ÷ 2 where:

λ (wavelength) = c × V f

÷ ∆ f

∆ f = 10 MHz between bumps

V f

(velocity factor)

≈ 1.0

c ≈ 10

9

ft/sec

λ

= 10

9

ft/sec

÷

10

7

cycles/sec = 100 ft

= 100 ft

÷

2 = 50 ft

-4-