3192 H2TU-C
JOB A ID
61222004L2-22A
0105
3192 H2TU-C
CLEI: T1L3X6AA_ _
1222004L2
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
LED STATUS
DSL
DSX
ALM
LBK
● Off
● Red
●
Yellow
●
Green
●
Off
No synchronization between H2TU-C and H2TU-R on the loop.
Poor signal quality on the loop (>10
-7
BER).
Marginal signal quality on the loop (
≤
2 dB margin above 10
-7
Good signal quality on the loop (> 2 dB margin above 10
-7
BER).
BER).
Network side DSX-1 signal is absent or is in a format that does not match the provisioning of the HDSL2 circuit.
✷
Blinking Bipolar Violation (BPV), frame bit error (SF mode) or CRC error (ESF mode) detected at
DSX-1 signal.
●
Solid
●
Off
●
Red
●
Yellow
●
Off
Network side DSX signal is present and synchronized.
No alarm condition detected.
Detected local alarm condition (H2TU-C) or locally and remotely (H2TU-C and H2TU-R).
Detected remote alarm condition (H2TU-R).
Unit is not in loopback or armed state.
● Yellow Active local bidirectional loopback from the H2TU-C toward the customer and the network.
✷
Blinking Unit is armed but not in active loopback condition.
BANTAM JACKS
MON
■ Provides a nonintrusive tap to monitor characteristics of the DSX signal
TX — monitors signal being received from the network
RX — monitors signal being transmitted to the network
EQ
■ Provides an intrusive signal interrupting access point to the data stream
TX — accesses the data stream being transmitted toward the customer
RX — accesses the data stream being received from the customer
RS-232 DB-9 CONNECTOR
■
■
■
Used to access the HDSL2 utilities menu tree via VT100 emulation software such as terminal, Hyper Terminal – Private Edition and ProComm Plus.
There are two types of terminal emulation modes, Manual and Real-Time. To toggle between the two, type “CTRL” and “T.” To update the screens while in Manual Mode, press the space bar 3 times. Real-Time Update Mode is the default mode.
Provision terminal port as follows:
Data Rate — 1.2 kbps to 19.2 kbps
Asynchronous Data Format — eight data bits, no parity (none), one stop bit, and no flow control.
■ When using a PC with terminal software, be sure to disable any power saving programs.
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of ADTRAN’s U.S. Carrier Networks
Equipment Warranty: (877) 457-5007, Document #414.
CIRCUIT BOARD 5-POSITION ROTARY SWITCH
Sets the DSX-1 Line Build Out (LBO). (Default settings are in bold .)
■
■
■
■
■
0 — 0-133 feet of LBO
133 — 133-266 feet of LBO
266 — 266-399 feet of LBO
399 — 399-533 feet of LBO
533 — 533-655 feet of LBO
CIRCUIT BOARD 6-POSITION DIP SWITCH
Provisions the unit. (Default settings are in bold .)
SW1-1
■ Selects line coding to AMI or B8ZS
SW1-2
■ Selects T1-framing to FRAMED or UNFRAMED 1
SW1-3
■ Selects T1-framing to SF or ESF
SW1-4
■ ENABLES or DISABLES the NIU loopback
SW1-5
■ ENABLES or DISABLES the loopback time out
2
SW1-6
■ ENABLES or DISABLES shelf alarm feature.
1
UNFRAMED operation ignores the setting of SW1-3
2
Default timeout setting is 20 minutes when loopback time out is ENABLED
COMPLIANCE CODES
This product is intended to be installed in an enclosure with an
Installation Code (IC) of “B” or “E” and in Restricted Access Locations only. Up to –200 Vdc may be present on telecommunications wiring.
The DSX-1 interface is intended for connection to intra-building wiring only.
Code
Installation Code (IC)
Input Output
A
Telecommunication Code (TC) –
–
X
Power Code (PC) F C
■
For complete Installation and Maintenance: (877) 457-5007, Document # 700. Please have your fax number available.
■
HDSL2 TROUBLESHOOTING GUIDE
Pricing and Availability 800.827.0807
Tech Support 800.726.8663
Return for Repair 256.963.8722
www.adtran.com
61222004L2-22A
INDICATIONS AND PROBABLE CAUSES
Front Panel or Circuit Parameters Indicate Abnormal Operation
■
■
■
Connect a terminal or PC to the RS-232 (DB-9) craft interface, located on the faceplate. The terminal must be VT100 or compatible and set for 1.2 to 19.2 kbps, 8 data bits, no parity, 1 stop bit, and no flow control. Select “3” from the ADTRAN HDSL2 Main Menu Screen and “2” from the
Span Status Screen:
Is signal quality fluctuating (this would occur when real-time mode is active)?
Is ATTEN (pulse attenuation) > 30 dB?
Are there any errors counting on the ES, SES, or UAS registers?
If the above conditions do not exist, the circuit should provide quality service; however, if any of the above conditions exist, cable problem or excessive loss situation is probable and more detailed cable testing should be done to verify all HDSL2 Loop Specifications are met. These conditions may also reflect intermittent cable faults or excessive noise impairments. If intermittent faults or noise impairments are suspected, select “5” from the HDSL2 Main Menu to review the Performance History Screen.
Front Panel Indications Under Normal Operation
DSL
DSX
ALM
LBK
●
Green
● Green
●
●
Off
● Off
Circuit Parameters Under Normal Operation
■ LOSS ≤ 30 dB
■ Good signal quality with no fluctuation
■ All HDSL2 Deployment Guidelines are met
HDSL2 DEPLOYMENT GUIDELINES
■
■
■
■
■
■
■
■
Cable pairs must be non-loaded
Total bridged tap < 2.5 kft
No single bridged tap > 2 kft
196 kHz insertion loss ≤ 35 dB
Pulse attenuation (loss on HDSL2 Span Status Screen) ≤ 30 dB
Maximum loop resistance is 900 Ω
Impulse noises < 50 dBrn as measured using a 50 kb filter
Wideband noise ≤ 31 dBrn as measured using a 50 kb filter
For more information regarding deployment guidelines and applications, reference ADTRAN’s
Supplemental Deployment Information for HDSL/HDSL2, P/N 61221HDSLL1-10.
HDSL2 Loopback Control Codes
Name
Arming (In-band)
Arming (ESF)
Activation
(H2TU-C)
Code
11000
0001 0010 1111 1111
(12 FF Hex)
1101 0011 1101 0011
(D3D3 Hex)
Activation
(H2TU-R)
Deactivation
1100 0111 0100 0010
(C742 Hex)
1001 0011 1001 0011
(9393 Hex)
Disarming (In-band) 11100
Disarming (ESF) 0010 0100 1111 1111
(24FF Hex)
Arming Time out N/A
Loopup Time out N/A
Loopback Time out 1101 0101 1101 0110
Override (D5D6 Hex)
Span Power
Disable
0110 0111 0110 0111
(6767 Hex)
Comments
Signal sent in-band or over ESF data link. HDSL2 elements in disarmed state make transition to armed state. Detection of either code results in
Smartjack loopup, if NIU loopback is enabled.
Signal sent in-band. HDSL2 elements in armed state make transition to loop-up state. Loop-up state timeout is programmable from the H2TU-C.
Signal sent in-band. HDSL2 element loopup state makes transition to armed state.
Signal sent in-band or over ESF data link. HDSL2 elements in any state make transition to disarmed state.
2 Hours
HDSL2 element in loopup makes transition to armed state.
Programmable from H2TU-C: None, 20, 60, or 120 minutes.
Signal sent in-band. Sets Loopback Timeout to NONE. Timeout will return to previous value when pattern is removed. Arming pattern
(11000) must precede this pattern.
Signal sent in-band. Disables span powering of remotes. Span power will return when pattern is removed. Arming pattern (11000) must precede this pattern.
advertisement
Related manuals