Whirlpool AKM 407/MR Hob Program Chart
Pubblicità
Pubblicità
AKM 407
FR
PRODUCT DESCRIPTION SHEET
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Medium burner 1.98 kw
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Medium burner control knob
Symbols
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/flame delivery and electric ignition
Minimum opening or reduced delivery
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burner ignites.
After the burner has ignited, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
5019 319 60381/A
The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.).
Important
Improper use of the grids can result in damage to the hob: do not position the grids upside down or slide them across the hob.
Do not use:
cast iron griddles or terracotta pots and pans
heat diffusers such as metal mesh, or any other types
two burners simultaneously for one receptacle
(e.g.fish kettle).
Whirlpool is a registered trademark of Whirlpool USA
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used
NATURAL GAS
(Methane) G20
Type of burner
Injector marking
128
94
Rated heat capacity kW
3.00
1.65
Rated consumption
286 l/h
157 l/h
NATURAL GAS
(Groningue) G25
LIQUID
PETROLEUM GAS
(Cylinder) G30
LIQUID
PETROLEUM GAS
(front right) G31 large medium medium
(front right) large medium medium
(front right) large medium medium
(front right) large medium medium
(front right)
102
128
94
102
85
65
70
85
65
70
1.98
2.78
1.53
1.84
3.00
1.65
1.98
3.00
1.65
1.98
189 l/h
308 g/h
170 g/h
204 g/h
218 g/h
120 g/h
144 g/h
214 g/h
118 g/h
142 g/h
Reduced heat capacity kW
0.60
0.35
Gas pressure (mbar) min.
rat.
max.
17 20 25
0.35
0.60
0.35
20 25 30
0.35
0.60
0.35
20 28-30 35
0.35
0.60
0.35
25 37 45
0.35
Type of gas used
Appliance model
G20 20 mbar
G25 25 mbar
G30 28-30 mbar
G31 37 mbar
4 gas
4 gas
4 gas
4 gas
ELECTRIC SUPPLY: 230 V - 50 Hz
Total rated heat capacity kW
8.28
7.68
8.28
8.28
Total rated consumption
789 l/h
852 l/h
602 g/h
592 g/h
Air required for burning m 3 /h
16.6
15.4
16.6
16.6
Scarica