Whirlpool AKM 250/IX Hob Program Chart
Iklan
Iklan
AKM 250
FR
PRODUCT DESCRIPTION SHEET
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
10.
Electric ignition button
Symbols
Shaded circle
Large flame
Small flame
Tap closed
Maximum opening/delivery
Minimum opening or reduced delivery
Operation of burners with electric ignition
To light one of the burners:
• Press the relative knob and turn it anti-clockwise to the large flame setting
• At the same time, press the button with the
.
star .
The spark plug gives out a spark that causes the burner to ignite.
If the burner does not ignite, repeat the operation.
5019 319 53901
Note:
— Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
Type of burner
NATURAL GAS
(Methane) G20
LIQUID PETROLEUM
GAS
(Cylinder) G30
LIQUID PETROLEUM
GAS
(Cylinder) G31 large medium small large medium small large medium small
128
94
76
85
65
50
85
65
50
Injector marking
Rated heat capacity
Pcs-kW
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
218 l/h
120 l/h
73 l/h
214 l/h
118 l/h
71 l/h
Rated consumption
Reduced heat capacity
Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
Gas pressure mbar min.
rat.
max.
17
20
25
20
28-30
37
25
35
45
Type of gas used
G20 20 mbar
G25 28-30 mbar
G31 37 mbar
Appliance model
4 gas
4 gas
4 gas
Total rated heat capacity Pcs-kW
7.30
7.30
7.30
Total rated consumption
695 l/h
531 g/h
521 g/h
Air required for burning m
3
/h
14.6
14.6
14.6
Unduh
Iklan