Whirlpool AKM 202/NB Hob Program Chart
Whirlpool AKM 202/WH is a 4-burner gas cooktop with electronic ignition. It has two medium burners, one large burner, and one small burner. The medium burners have a rated heat capacity of 1.65 kW each, the large burner has a rated heat capacity of 3.00 kW, and the small burner has a rated heat capacity of 1.00 kW. The cooktop is designed for use with natural gas or liquid petroleum gas. The required gas pressure for natural gas is 17-25 mbar, and for liquid petroleum gas is 20-35 mbar. The total rated heat capacity of the cooktop is 7.30 kW.
Διαφήμιση
Διαφήμιση
AKM 202
GB
PRODUCT DESCRIPTION SHEET
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
Symbols
Shaded circle Tap closed flame and star
Small flame delivery and electronic ignition
Minimum opening or reduced delivery
Operation of burners electronic ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star setting .
• At the same time, keep the knob pressed against the control panel until the burner ignites.
• Release the knob.
If the burner does not ignite, repeat the operations described above.
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
5019 319 01219
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used
Type of burner
Injector marking
Rated consumption
Gas pressure
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningen) G25
LIQUID
PETROLEUM GAS
(Cylinder) G30
LIQUID
PETROLEUM GAS
(Cylinder) G31 large medium small large medium small large medium small large medium small
128
94
76
128
94
76
85
65
50
85
65
50
Rated heat capacity
Pcs-kW
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
308 l/h
170 l/h
103 l/h
218 l/h
120 l/h
73 l/h
214 l/h
118 l/h
71 l/h
Reduced heat capacity
Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min.
rat.
17
20
20
25
20
25
28-30
37 max.
25
30
35
45
Type of gas used
G20 20 mbar
G25 25 mbar
G30 28-30 mbar
G31 37 mbar
Appliance model
4 gas
4 gas
4 gas
4 gas
Total rated heat capacity
Pcs-kW
7.30
6.77
7.30
7.30
Total rated consumption
695 l/h
751 l/h
531 l/h
521 l/h
Air required for burning m
3
/h
14.6
13.5
14.6
14.6
Λήψη