Whirlpool G2P HG 62/SS Hob Program Chart
Advertisement
Advertisement
G2P HG62
GB
PRODUCT DESCRIPTION SHEET
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
10.
Electric ignition button
Symbols
Shaded circle
Large flame
Small flame
Tap closed
Maximum opening/ delivery
Minimum opening or reduced delivery
Operation of burners with electric ignition
To light one of the burners:
Press the relative knob and turn it anticlockwise to the large flame setting .
At the same time, keep the push-button with a star .
The spark plug gives out a spark that causes the burner to ignite.
If the burner does not ignite, press the push- button again.
5019 319 54231
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS
(Methane) G20
NATURAL GAS
(Cylinder) G30
NATURAL GAS
(Cylinder) G31
Type of burner large medium small large medium small large medium small
Injector marking
100/mm
128
94
76
85
65
50
85
65
50
3.00
1.65
1.00
3.00
1.65
1.00
Rated heat capacity kW
3.00
1.65
1.00
Rated consumption
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
0.60
0.35
0.30
Reduced heat capacity kW
0.60
0.35
0.30
Gas pressure mbar min.
17
20
25 rat.
20
28-30
37 max.
25
35
45
Type of gas used
Appliance model
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
4 gas
4 gas
4 gas
Electric supply: 230 V - 50 Hz
Total rated heat capacity kW
7.30
7.30
7.30
Total rated consumption
695 l/h
531 g/h
521 g/h
Air required for burning m 3 /h
14.6
14.6
14.6