SVT SVT-MF4, SVT-MF4 Outdoor Station E User Manual


Add to my manuals
16 Pages

advertisement

SVT SVT-MF4, SVT-MF4 Outdoor Station E User Manual | Manualzz

SVT-

MF 4

Outdoor Station

A

User Manual

Please read this user manual prior to installing the system, and keep it well for future use.

CONTENTS

1. Parts and Functions..................................................................................

.

...........

1

2. Terminal Descriptions ..........................................................................................

2

3. Specification s...

....................................................................................................

3

4.

Mounting .........................................................................................

.

.....................

3

4 .1

Mounting without the Rain Guard ........

.

...............

......

.............

....

...........

.

...

.

......

3

4 .2 Mounting with the Rain Guard........

................

......

......

...........

...............

.

.

.

...

.

.....

4

4 .

3 Mounting the Indoor Monitor.

.................

......

..

....................

....................

.

.

........

4

5. System Wiring and Connections .........................................................................

5

5.1

SVT-4 System with one entrance ..................

.

...............

......

.............

.....

...

.

......

5

5.2 SVT-4 System with two entrances .............................

......

......................

.

........

6

5.

3 SVT-4 Wiring Connection ..................

.

...............

....................

.............

.....

......

7

5.

3 .1

Indoor Station....................

..................

.

...............

.............

.............

.....

......

7

5.

3 .2

Outdoor Station.................

..................

.

..............

..............

.............

.....

..

..

..

7 -8

5.

3 .

3 Electric door lock connection ..........

....

.

..............

..............

.............

.....

......

9

6.

Cable Requirements .............................................................

..................

..

.

.........

10

7. User Instructions . .......................

.........................................

...............................

1 1

7 .1

Visitor calls ...................................

..................

.

..............

......

.............

......

...

.

...

1 1

7 .2 Monitor .........................................

.............................

......

......................

.

.......

1 2

7 .

3 Intercom .............

...........................

.....

.

...............

....................

.............

.....

.....

1 3

1.Parts and Functions

#

1

2

3

4

5

6

Description

LED lights

High resolution camera

Built-in speaker

Call button

Built-in microphone

Name plate

Status light.

Calling in: red light

Monitoring/Talking: blue light

3

# Description

3

4

1

2

5

6

Built-in microphone

Monitor button

Intercom button

Door unlock button

Talk button

TFT 7” color display

7

8

Built-in speaker

Talking/Ring volume

9 Brightness

10 Contrast

-1-

-2-

2.Terminal Descriptions

3.Specification

s

OUTDOOR STATION

Voltage : DC 14.5V

NO /NC /COM : Max. 14.5V 2 0 0mA

Lock Power Supply: Must be used according to lock.

Unlocking time: 01 - 35 seconds with SVT-TD20G device

Communication duration: 120s.

Communication transmission : 2-way comm unication

Working temperature: -4°F to 131°F / -20°C to +55°C

INDOOR MONITOR

Voltage : DC 14.5V

Communication duration: 120s.

Communication transmission : 2-way comm unication

Working temperature: 14°F to 131°F / -10°C to 55°C

4.Mounting

4 .

1 .

MOUNTING WITHOUT THE RAIN GUARD

1 2

Install in to the wall

Screw hole

160-165 cm

Screws

(fix with button case)

-3-

-4-

4 .

2 .

MOUNTING WITH THE RAIN GUARD

Wall hole

Screw anchors

Rain cover

Screws

4 .

3 .

MOUNTING THE INDOOR MONITOR

Screws

(fix with rain cover)

5.

System Wiring and Connections

5.1.

SVT -MF 4 SYSTEM WITH ONE ENTRANCE

-5-

-6-

5.2.

SVTMF 4 SYSTEM WITH TWO ENTRANCES

5.3. SVT-4 WIRING CONNECTION

5.3.1

Indoor Monitor

1. Red 2. Blue 3. Yellow

1-Audio 2-GND 3-V+

4. White

4-Video

1. Red

2. Blue

3. Yellow

4. White

1. Red

2. Blue

3. Yellow

4. White

CN1: Connect to the first Outdoor Station

CN2: Connect to the second Outdoor Station

NOTE: Do not remove any of the jumpers from the back of the indoor monitors.

By removing a jumper or changing its position, some of the features may not work properly.

5.3.2 Outdoor Station

Upper module:

CN1

:

Must remain connected to CN10 port on the lower module.

Lower module:

PWR: Connect a SVT-MF4 PS17 Power supply.

J3: Use this port to connect a door lock.

The door lock is limited to 14.5V, 200mA.

Must use an additional power supply for the door lock. Ensure the power supply is compatible with the door lock specifications.

The J3 output is also DRY contact (NO/COM/NC).

CN10: Must remain connected to J1 port on the upper module.

CN22: Reserved port.

JP1: Remove the black jumper if a access control unit is connected to the outdoor station

(SVT-3100 / SVT-4100 / SVT-5100 Access Control System only).

J1: Connect the access control unit (SVT-3100 / SVT-4100 / SVT-5100 Access Control

System only).

CN3: Reserved port.

CN2: Connect to the indoor monitor (Upper call button )

CN1: Connect to the indoor monitor (Lower call button )

-7-

-8-

5.3.3 Electric Door Lock Connection

1. Use the port J3 of the lower module to connect a door lock.

2. The door lock is limited to 14.5V, 120mA.

3. Must use an additional power supply for the door lock. Ensure the power supply is compatible with the door lock specifications.

-9-

-10-

6 .Cable Requirements

Cable Usage A B

CAT5 cable ( must solder the wires together to ensure a good connection ) .

Using different cables may affect the maximum distance the system can reach.

2 3 0 feet

7 0 meters

30 feet

1 0 meters

NOTE:

1.

The system expands to a maximum of 2 outdoor stations and 4 indoor monitors.

2. Each indoor monitor requires its own power supply(14.5V, 1.3A)

3. We recommend soldering the wires together to ensure a good connection (Do not use wire nuts).

4 . For long runs typically longer then 90ft, we recommend using coax cable for the video function.

A

B

7.

User instructions

7.1

Visitor calls

The visitor presses the call button on outdoor station-1

The visitor presses the call button on outdoor station-2

Ring Ring

The visitor image shown on the monitor

Press the call button at anytime, the indoor monitor will show the view from the front door camera automatically. Press talking button to have communication with the visitor by the front door.

Talk begins

Check

Open the lock

After pressing the unlocked button, the indoor monitor still displays the image from the front door camera.

The talk time is up to 2 minutes

Press the TALK button or hang-up the handset

End the call

-1 1 -

-1 2 -

7.

2 Monitor

Press the monitor button

Press once

Monitor outdoor station 1

The indicator light of

Door 1 is on.

Press the talk button

Press twice

Monitor outdoor station 2

The indicator light of

Door 2 is on.

Press the monitor button

Monitor the outdoor station

Press the talk button

End the monitor

Call transferring from main indoor monitor to extension indoor monitor

During the between the station and conversation outdoor the indoor the main indoor monitor.

monitor, press button on

All indoor monitors ring

The indoor monitor press button again to end the conversation.

Any indoor monitor press button or pick up the handset to talk with the outdoor station.

7.3

Intercom

In the standby mode, press button intercom in any indoor monitor

All indoor monitors ring

Any indoor monitor presses button or pick up the handset to talk.

Talk begins

Press the TALKPress the

TALKING button or hang-upbutton or hangup the handsetthe handset

End the call

During the talking, any indoor monitor presses the intercom button

-1 3 -

The design and specifications of this user manual can be changed without any notification to the user.

All copyright and interpretation rights are reserved to SVT Innovations Inc.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement